BRIDGE: Brain-Vision Representation Integration through Depth and Granularity Encoding
Chenyuan Hong, Binghao Ye, Yufei Guo, Guoqi Li
NeurIPS 2026
Abstract. Decoding visual content from non-invasive brain signals remains challenging because neural responses evolve over time whereas images are typically static. Most existing methods align an entire neural response window to a single final visual embedding, potentially overlooking a fundamental representational mismatch: brain signals reflect both early perceptual and later integrative representations, whereas the final visual embedding is biased toward high-level semantics. Therefore, we propose BRIDGE, a brain-vision representation integration framework that aligns two modalities through Visual Depth Encoding and Brain Granularity Encoding. On the visual side, BRIDGE extracts and fuses CLIP representations from multiple depths, producing an alignment target that preserves low-level and high-level information. On the brain side, BRIDGE partitions stimulus-evoked EEG/MEG responses into a small number of ordered temporal segments and aggregates their representations through learnable attention pooling, allowing the model to capture temporal heterogeneity. The resulting brain and visual embeddings are trained in a shared latent space by contrastive learning and can further support brain-to-image generation through a pretrained diffusion prior. Experiments on THINGS-EEG and THINGS-MEG demonstrate that BRIDGE achieves strong retrieval and generation performance. Ablation studies further confirm the complementary benefits of depth-wise visual aggregation and temporal brain factorization. Code is available at https://github.com/hcy1026/BRIDGE.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 4 reviews · OpenReview
Updated 25 Nov 2026, 03:42 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper proposes a new model for predicting non-invasive human electrophysiology (EEG/MEG) responses to static natural images using the THINGS dataset. The proposed approach includes two main innovations: a time-resolved neural encoding architecture and a multi-scale encoding of visual stimuli. The two embeddings (brain and visual stimulus) are trained to align via a contrastive loss. The reviewers agree on the technical solidity of the model and the importance of the research question. As noted by the reviewers, demonstrating the model's applicability across both EEG and MEG data is a valuable contribution.
I encourage the authors to review all comments in detail and do their best to address all raised concerns and suggestions. Below, I highlight a few substantial points that I believe must be addressed for the paper to be considered a strong candidate for acceptance at NeurIPS:
-
Reviewer JhMy raises an important question with respect to the train/test split differences between THINGS EEG and MEG. Please ensure this concern is thoroughly addressed. Additionally, two reviewers noted discrepancies where certain results were reported exclusively for EEG; these should be provided or clarified for MEG as well.
-
Reviewer a7h5 raises interesting questions regarding the interpretation of the trained model—specifically the correspondence between CLIP depth and the pre-segmented EEG/MEG temporal windows discovered by the model. They also request critical details about the experimental paradigms used during data collection (e.g., stimulus presentation duration, pre- and post-stimulus intervals). Overall, the points raised by Reviewer a7h5 regarding model architecture, training data, and hyperparameter choices are essential details that require clear clarification.
-
All reviewers raised concerns about partitioning EEG/MEG responses into uniform temporal segments. A clearer justification for this design choice is needed, including how this choice was made and the underlying neurophysiological rationale. Furthermore, please clarify why finer partitioning led to worse performance compared to the baseline.
Final justification
The authors have done a great job addressing the reviewers' concerns. Two out of four reviewers were already positive regarding acceptance, and in my reading of the rebuttal, their primary concerns have been effectively resolved through new experimental results and clarifications. The other two reviewers had some reservations. Based on my assessment, most of these issues have been adequately addressed, although a few concerns remain for one reviewer. I believe the authors made their best effort to resolve these points within the limited timeframe of the rebuttal and discussion period. While these remaining concerns are noted, the strong support from the two positive reviewers, alongside the overall significance of the paper's contributions, leads me to recommend acceptance.
Read meta-review
Meta-review
The paper proposes a new model for predicting non-invasive human electrophysiology (EEG/MEG) responses to static natural images using the THINGS dataset. The proposed approach includes two main innovations: a time-resolved neural encoding architecture and a multi-scale encoding of visual stimuli. The two embeddings (brain and visual stimulus) are trained to align via a contrastive loss. The reviewers agree on the technical solidity of the model and the importance of the research question. As noted by the reviewers, demonstrating the model's applicability across both EEG and MEG data is a valuable contribution.
I encourage the authors to review all comments in detail and do their best to address all raised concerns and suggestions. Below, I highlight a few substantial points that I believe must be addressed for the paper to be considered a strong candidate for acceptance at NeurIPS:
-
Reviewer JhMy raises an important question with respect to the train/test split differences between THINGS EEG and MEG. Please ensure this concern is thoroughly addressed. Additionally, two reviewers noted discrepancies where certain results were reported exclusively for EEG; these should be provided or clarified for MEG as well.
-
Reviewer a7h5 raises interesting questions regarding the interpretation of the trained model—specifically the correspondence between CLIP depth and the pre-segmented EEG/MEG temporal windows discovered by the model. They also request critical details about the experimental paradigms used during data collection (e.g., stimulus presentation duration, pre- and post-stimulus intervals). Overall, the points raised by Reviewer a7h5 regarding model architecture, training data, and hyperparameter choices are essential details that require clear clarification.
-
All reviewers raised concerns about partitioning EEG/MEG responses into uniform temporal segments. A clearer justification for this design choice is needed, including how this choice was made and the underlying neurophysiological rationale. Furthermore, please clarify why finer partitioning led to worse performance compared to the baseline.
Final justification
The authors have done a great job addressing the reviewers' concerns. Two out of four reviewers were already positive regarding acceptance, and in my reading of the rebuttal, their primary concerns have been effectively resolved through new experimental results and clarifications. The other two reviewers had some reservations. Based on my assessment, most of these issues have been adequately addressed, although a few concerns remain for one reviewer. I believe the authors made their best effort to resolve these points within the limited timeframe of the rebuttal and discussion period. While these remaining concerns are noted, the strong support from the two positive reviewers, alongside the overall significance of the paper's contributions, leads me to recommend acceptance.
1 comment
- Rating
- 3/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes BRIDGE, a brain-vision representation alignment framework for EEG/MEG-based visual decoding. The main motivation is that brain responses evolve over time, while visual representations in pretrained vision models evolve across network depth. To reduce this mismatch, the paper introduces two modules: Brain Granularity Encoder (BGE), which partitions the brain response window into temporal stages and adaptively pools them, and Visual Depth Encoder (VDE), which extracts and fuses CLIP features from multiple depths. The resulting brain and visual embeddings are aligned using a symmetric contrastive objective. The learned representations are further used for brain-to-image generation by connecting the brain encoder to a pretrained diffusion prior. Experiments on THINGS-EEG and THINGS-MEG show strong retrieval performance, especially on THINGS-EEG, and the ablation studies suggest that both temporal factorization and multi-depth visual features contribute to the final performance.
Strengths and weaknesses
Strengths
The paper identifies an interesting and meaningful mismatch between temporally evolving brain responses and static high-level visual embeddings. This motivation is clear and biologically plausible.
The proposed framework is simple and well structured. BGE and VDE correspond naturally to the temporal hierarchy of brain signals and the depth hierarchy of visual encoders, respectively.
The empirical results are strong on THINGS-EEG. In particular, the method improves substantially over prior methods in both intra-subject and inter-subject retrieval settings.
The ablation studies provide useful evidence that the two proposed components contribute to the performance. In particular, removing VDE causes a large performance drop, suggesting that multi-depth visual features are important for the alignment target. Removing BGE also leads to a moderate but consistent drop, supporting the usefulness of temporal factorization.
Weaknesses
The main weakness is that the component-level evidence is not as broad as the paper’s claims. The method is evaluated on both THINGS-EEG and THINGS-MEG in the main comparison, but the key ablations for BGE, VDE, the number of brain stages, and the number of visual stages are mainly reported on THINGS-EEG. Since EEG and MEG have different signal characteristics, the current ablation results do not fully establish that the proposed components are equally effective for MEG.
The temporal-stage ablation only partially supports the broader motivation. The two-stage setting improves over the baseline, but finer partitions often perform worse, sometimes substantially worse than the baseline. This supports the specific two-stage design, but it provides weaker evidence for the general claim that temporal granularity modeling robustly captures hierarchical brain dynamics. It also suggests that the method may be sensitive to the stage number and that uniform temporal partitioning may not be a generally robust solution.
The role of VDE in the generation pipeline is not sufficiently analyzed. The paper argues that VDE preserves multi-depth visual information, but in the generation stage the VDE embedding is mapped into a pretrained diffusion conditioning space. It is therefore unclear whether the low- and mid-level information captured by VDE is preserved after this mapping, or whether the generation process mainly relies on high-level semantic information. A generation-specific ablation comparing VDE with final-layer CLIP features under the same diffusion prior would strengthen this part.
The method is mainly validated with a fixed CLIP ViT-B/32 visual backbone. Although the paper studies different layer selections within this backbone, it does not show whether the proposed VDE design remains effective across different CLIP variants, model sizes, or visual foundation models. This limits the generality of the conclusion that depth-wise visual aggregation is broadly beneficial.
The validation protocol is not fully clear. The paper reports results under standard zero-shot splits, but it is not obvious whether an independent validation set was used to select important design choices such as the number of brain stages, the CLIP layer set, and other hyperparameters. Clarifying this point would help rule out concerns about benchmark-specific tuning.
Questions
Several concerns raised in the Weaknesses section would benefit from further clarification:
-
Could the authors provide component-level ablations, especially w/o BGE and w/o VDE, on THINGS-MEG? This would clarify whether the conclusions drawn from the EEG ablations generalize to MEG.
-
Could the authors clarify how the number of brain stages and the selected CLIP layers were chosen? Was there an independent validation set for these choices, or were they selected based on test-set performance?
-
In the generation pipeline, VDE embeddings are mapped into a diffusion conditioning space. Could the authors provide analysis or ablations showing whether the low- and mid-level information from VDE is preserved after this mapping?
-
Could the authors test or discuss whether VDE remains effective with other CLIP backbones or visual foundation models beyond ViT-B/32? Even a small-scale experiment with another backbone would help support the generality of the method.
-
The temporal-stage ablation shows that two stages work best, while finer partitions often hurt performance. Could the authors explain why a uniform two-stage partition is the most appropriate choice, and whether adaptive or learned temporal boundaries were considered?
A satisfactory response to the above questions, especially additional MEG ablations and a clearer validation protocol, would positively affect my assessment of the paper.
Limitations
N/A
Formatting concerns
N/A
2 comments
Rebuttal
Thank you for your careful and constructive assessment. Below, we respond point by point to your concerns, particularly regarding MEG, generation, and alternative visual backbones. We will incorporate the corresponding results and clarifications into the revised manuscript.
1. Component-level ablations on THINGS-MEG
Thank you for raising this important concern. We conducted the requested component-level ablations under the THINGS-MEG intra-subject protocol:
| Setting | Top-1 (%) | Top-5 (%) |
|---|---|---|
| w/o BGE | 30.75 | 60.92 |
| w/o VDE | 25.60 | 53.90 |
| w/o both | 25.13 | 53.75 |
| Full BRIDGE | 33.13 | 61.46 |
The full model improves Top-1 by 2.38 points over w/o BGE, 7.53 points over w/o VDE, and 8.00 points over w/o both. The overall pattern observed on EEG is therefore also present on MEG: VDE provides the larger individual gain, while BGE offers an additional complementary improvement. These results support the effectiveness and complementary contributions of both BGE and VDE for MEG decoding.
2. Validation protocol and selection of stages, layers, and hyperparameters
Thank you for the important question. As described in Sec. 4.1 and Appendix A.4, we follow the official zero-shot benchmark partitions and evaluation protocol adopted by recent prior works, including BrainHiVE.
Regarding the architectural choices, the default brain-stage number S = 2 was selected based on the stage-number ablation on the official test split, with additional visualized evidence provided in Appendix G. Two stages achieved 78.87%/96.15% Top-1/Top-5 accuracy, compared with 75.70%/94.60% for the whole-window baseline. Three stages also weakened performance relative to the two-stage setting, and finer partitions caused larger degradation. For VDE, candidate layers were sampled approximately uniformly across the visual backbone. The four-, five-, and six-depth variants all performed strongly, and we selected layers 2, 5, 8, and 11 because they provide broad depth coverage at a lower computational cost than denser alternatives.
All remaining optimization hyperparameters follow BrainHiVE and are fixed across the full model and all ablation variants, as specified in the Experimental Settings: AdamW with an initial learning rate of 5 × 10⁻⁴, cosine decay, weight decay 0.05, 25 training epochs, batch size 1024, embedding dimension 1024, and initial temperature 0.07.
3. Whether VDE information is preserved in the generation pipeline
Thank you for this insightful question. To directly assess whether the information introduced by VDE remains useful after mapping into the diffusion-conditioning space, we conducted a controlled generation-specific comparison on Subject 8. Both variants used the same input samples, the same random seed, the same frozen diffusion backbone, the same default pretrained IP-Adapter weights, and identical inference settings. Only the visual alignment target was changed.
| Visual target | PixCorr ↑ | SSIM ↑ | Alex-2 ↑ | Alex-5 ↑ | Inception ↑ | CLIP ↑ | SwAV ↓ |
|---|---|---|---|---|---|---|---|
| Final feature only | 0.0868 | 0.2558 | 0.4928 | 0.4781 | 0.4878 | 0.5236 | 0.7245 |
| Layers 2, 5, 8, 11 + final | 0.1112 | 0.2678 | 0.4919 | 0.4853 | 0.4942 | 0.4917 | 0.7215 |
The full VDE target clearly improves the low-level reconstruction metrics, increasing PixCorr from 0.0868 to 0.1112 and SSIM from 0.2558 to 0.2678. It also improves AlexNet-5, Inception, and SwAV, while AlexNet-2 remains nearly unchanged. In an additional compact setting using layers 2 and 5 together with the final feature, PixCorr and SSIM also increase to 0.1046 and 0.2616. The consistent improvements in these low-level metrics directly support that shallow and intermediate information remains available after the conditioning mapping rather than being discarded.
Because this controlled comparison uses the default pretrained IP-Adapter without a target-specific prior or adapter fine-tuning, it is naturally better calibrated to native final CLIP embeddings, which may disadvantage VDE on CLIP-based semantic metrics. Nevertheless, VDE improves PixCorr and SSIM under this conservative setting, directly showing that low- and mid-level information remains preserved and usable after conditioning-space mapping. Target-specific fine-tuning may further improve semantic metrics, but would introduce an additional training factor into the comparison.
4. Generality across different visual backbones
Thank you for this helpful suggestion. We further evaluated VDE using CLIP ViT-H-14 and CLIP RN50. For ViT-H-14, which contains 32 visual transformer blocks, we extract hidden representations from blocks 8, 16, 24, and 31, together with the final projected CLIP embedding. For the CLIP RN50 visual backbone, which uses CLIP's modified ResNet-50 architecture, we extract the outputs of its four successive residual stages together with the final attention-pooled and projected embedding. VDE is therefore adapted to the natural depth hierarchy of each architecture rather than directly reusing the ViT-B/32 layer indices.
| Backbone | Visual target | Intra Top-1/Top-5 (%) | Inter Top-1/Top-5 (%) |
|---|---|---|---|
| CLIP ViT-H-14 | Final only | 42.88 / 73.45 | 17.78 / 40.17 |
| CLIP ViT-H-14 | VDE | 71.35 / 93.50 | 34.11 / 65.22 |
| CLIP RN50 | Final only | 12.87 / 32.17 | 14.56 / 32.94 |
| CLIP RN50 | VDE | 67.07 / 91.90 | 32.00 / 61.80 |
The intra-subject experiments use all ten subjects. Due to the rebuttal-time constraint, the inter-subject experiments were completed on held-out Subjects 1–3.
VDE substantially improves both intra-subject and inter-subject performance for ViT-H-14. It also remains effective when the visual architecture is changed from a transformer to the convolutional CLIP RN50 backbone. These results indicate that the benefit is not tied to the specific dimensions or layer indices of ViT-B/32, but arises from aggregating representations distributed across the depth hierarchy of the pretrained visual encoder.
5. Why uniform two-stage partitioning is used
We appreciate this valuable question. The central goal of BRIDGE is to retain multilevel information in both modalities, rather than aligning an entire neural response only with the final visual embedding. BGE exposes temporally ordered neural evidence, while VDE preserves the shallow-to-deep visual trajectory, making both perceptual and integrative information available for brain–vision alignment.
We use uniform partitioning as a simple and stable way to expose coarse temporal heterogeneity. Neural response latency and duration vary substantially across participants, stimuli, and recording modalities. Existing neuroscience studies support a broad progression from earlier perceptual processing toward later integrative processing, but we did not find evidence specifying a single temporal boundary that can be applied precisely across EEG/MEG participants and stimuli. It is consequently difficult to define exact temporal boundaries that can also be reliably paired with particular CLIP depths without introducing strong additional assumptions.
Finer uniform partitioning is not necessarily more effective. Increasing the number of stages shortens each temporal segment, fragments low-SNR and non-stationary neural evidence, increases sensitivity to participant- and stimulus-dependent latency shifts, and reduces the amount of reliable information available to each segment encoder. This is consistent with the ablation: S = 2 improves over the whole-window baseline, whereas S = 3 already weakens performance and four or more stages cause substantially larger degradation. Appendix G provides complementary visualized evidence: the 1D and 2D LDA visualizations show cleaner and more stable separation for the two-stage features. The two-stage setting therefore offers a practical balance between exposing coarse temporal heterogeneity and retaining sufficient neural evidence within each segment.
We agree that more precise temporal modeling remains an important open direction. We explored two adaptive alternatives: overlapping sliding-window attention and learnable soft temporal gates. However, both increase the number of trainable parameters, computational cost, and optimization difficulty. In our preliminary experiments, both variants reduced absolute Top-1 accuracy by more than 0.20 and exhibited less stable training. These results suggest that adaptive partitioning requires substantially more careful architectural design and dataset-specific tuning than simply replacing the uniform split with a learnable boundary. Future work will investigate these issues together with participant-dependent latency, stimulus-dependent response duration, and more detailed studies of human visual-processing dynamics.
We sincerely appreciate your constructive suggestions once again. We hope our responses clarify your concerns, and we would be happy to address any further questions.
Thank you for your thoughtful comments and for the time you have invested in our work. We have posted our response and hope the above clarifications and the additional experiments sufficiently addressed your concerns. If any questions remain unresolved, please let us know. We would be grateful to clarify further and are happy to discuss specific points.
- Rating
- 2/6
- Confidence
- 5/5
- Quality
- 1/4
- Clarity
- 1/4
- Significance
- 1/4
- Originality
- 1/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper takes inspiration from what is known about hierarchical visual processing to design a hierarchical encoding of vision and neural recordings to improve clip retrieval and reconstruction from EEG and MEG.
Strengths and weaknesses
Strengths:
- Brain inspired encoding: The paper recognisises that visual processing is hierarchical and builds bespoke encoders for vision and neural data to model this. However, this is not new as it was previously proposed in the BRAINHIVE paper
- Results are benchmarked against many competing methods and appear impressive at first appraisal
Weaknesses:
- The ideas of how learning networks map onto human visual networks started with the CNN literature and some of this should be cited The authors reflect neural processing as time resolved but do not link this to the actual hierarchical processing of human brain visual processing e.g. Van Essen, D. C., & Gallant, J. L. (1994). Neural mechanisms of form and motion processing in the primate visual system. Neuron, 13(1), 1–10. https://doi.org/10.1016/0896-6273(94)90455-3. [1]
- Overall the methodological choices for the proposed architecture appear ad hoc, are not neurobiologically motivated nor fully validated through ablation. These issues are expanded on through the rest of my points
- The partition of EEG responses into uniform temporal segments lacks neurophysiological grounding. Given that visual processing exhibits variable latency across stages, a uniform temporal split is likely suboptimal and lacks the adaptivity required to capture true neural dynamics. Based on their literature review and vision encoding approach one would assume that it would make more sense just to pass all data to a transformer and let it work out hierarchical features.
- Authors refer to a “CLIP encoder” but as far as I am aware CLIP is an alignment scheme for multimodal foundation models, the encoder is a vision transformer. Such terminology misuse reduces my confidence in the work overall
- Similarly the embedding dimensions from each transformer layer can be set to be equal. The number of tokens should be equal;. Therefore the comment about feature distribution and dimensionality varying doesn’t make sense and needs justifying. The meaning of ‘uniformly-spaced sampling features from multiple depths’ (sec 4.3) is not clear.
- The proposed cross-depth fusion step is reductive. The authors fail to justify why this simple residual MLP aggregation is superior to direct utilization of pre-trained hierarchical features or attention-based fusion mechanisms.
- The ablation study shows much of the performance gain comes from the video encoder which undermines the design of the BGE encoder (as flagged above)
- Reconstruction results in figure 2 do not match state of the art and this is further underlined in table 13.
- The results are reported without confidence intervals or statistical significance tests, and it's unclear whether the improvements over baselines are statistically significant or fall within the range of variance. The BRIDGE model does not consistently outperform baselines, for example in Table 7 and 13,
- The paper claims that earlier EEG stages align with shallower CLIP layers and later EEG stages with deeper ones, but provides no evidence. Can the authors provide supporting evidence and visualisations to justify this claim?
- The authors claim zero-shot generalization to held-out categories; however, because the visual encoder (CLIP) is frozen and pre-trained on large-scale datasets, it inherently possesses high-fidelity semantic representations for these 'held-out' categories. The evaluation therefore measures the decoder’s ability to align to pre-existing visual features rather than its capacity to generalize to novel semantic concepts.
Questions
- Why did the authors use manual segmentation of the EEG data. Did they try anything else? How do they justify their parcellation scheme? How does performance change for different numbers of temporal segments? What if they are different lengths? What if they use layers of a transformer encoder?
- Based on appendix G authors seem to have performed some analysis based on a linear classifier. This raises the question of how their proposed BGE performs against simple linear regression?
- Given that CLIP's final embedding is already an optimized global semantic representation, can the authors please explain why their ad-hoc cross fusion layer is not simply introducing unnecessary dimensionality reduction, noise, and overfitting, particularly given the scarcity of paired brain-vision data
- Many papers now report classifiation and reconstruction but it seems evident that this is largely being driven by the power of vision transformer encoders and diffusion generative models. What evidence can the authors present that would evidence that their method would inform cognitive neuroscience research? what research questions can be answered from this?
Limitations
The concept is sound but not novel and the implementation is overly simple and the validation lacks rigour and transparency. My sense is that performance is being driven by a pretrained vision encoder - resulting in effective data leakage because left out categories will have been seen during decoding. Not all experiments outperform baselines with these results hidden in the appendix. It has been really very difficult to review this paper because so many details are buried in the appendix. The authors would need to do a lot more to demonstrate that this model is really leading to neurobiologically meaningful and interpretable benefits for EEG decoding, with evidenced benefits for downstream applications that go beyond reconstruction and category prediction within dataset.
Final justification
The authors response is long but not substantial and does address my request to prove that this method is downstream useful rather than just benchmarking on standard metrics. The response on neuroscience utility is especially brief, no statistics were generated.
Formatting concerns
The paper is extremely difficult to evaluate with many key results and experimental details buried in the appendix. I would request that all information regarding dataset preprocessing, experimental set up are moved to main paper. The results of all tables, inclding those indicating worse recon performance need to be reference in the main text
2 comments
Rebuttal
Thank you the detailed critique.
1. Prior work, BrainHiVE, and visual hierarchy
The manuscript already cites time-resolved visual-processing studies [14,15] and, in Related Work, studies connecting CNN network depth with hierarchical visual processing [16,24,25,32]. We will clarify this historical development and add further CNN–brain work, together with Van Essen and Gallant (1994) for the anatomical and functional hierarchy of the primate visual system.
Our novelty claim is not that hierarchical vision is new, but that BRIDGE constructs dynamic hierarchical information across the two modalities. As stated in Secs. 1–2, BrainHiVE combines final outputs from separately pretrained visual encoders, treating the hierarchy as separate fusion endpoints. BRIDGE instead samples multiple depths within one frozen CLIP vision encoder. Because these representations share one architecture and pretraining objective, they form a more continuous shallow-to-deep trajectory than heterogeneous encoder endpoints. BGE then exposes ordered temporal information on the brain side.
2. Temporal segmentation, adaptive alternatives, and Transformers
Our motivation is that stimulus-evoked brain signals contain hierarchical information unfolding over time rather than one homogeneous representation. This is consistent with established time-resolved visual-processing studies [14–16,30–34], providing the neurophysiological background for explicitly retaining early-to-late information. The exact organization remains open: latencies overlap and vary across participants and stimuli, and the literature does not provide one boundary transferable directly to scalp EEG/MEG. We therefore use a uniform two-stage factorization as a simple, parameter-free approximation and evaluate it empirically.
The whole-window baseline obtains 75.70/94.60 Top-1/Top-5; two stages obtain 78.87/96.15, whereas 3–6 stages obtain 75.92/94.58, 66.33/91.33, 33.52/60.63, and 46.65/77.67. Appendix G uses LDA post hoc to compare separability across granularities. These results show that coarse early-to-late factorization is useful, whereas excessively fine partitioning fragments low-SNR evidence.
We also explored overlapping sliding-window attention, learnable soft gates, and differentiable adaptive boundaries. Without extensive dataset-specific tuning, all were more than 0.2 Top-1 accuracy below two-stage BGE. Their flexibility can follow participant- and stimulus-specific latency fluctuations rather than stable structure.
Transformer/self-attention brain modeling has already been explored by NICE [5], ATM [7], and related decoders. BrainHiVE [18] subsequently obtained stronger benchmark performance using a simple MLP projection, showing that greater sequence-model complexity is not automatically advantageous here. Moreover, global self-attention mixes all time points from the first layer: it learns flexible dependencies but does not itself impose or identify a neurobiologically meaningful hierarchy. We therefore chose an explicit low-capacity temporal factorization rather than assuming that a Transformer would automatically recover neural stages.
3. CLIP terminology, feature dimensions, and depth selection
“CLIP encoder” is not terminology misuse. CLIP contains image and text encoders, and our method uses its ViT-based image encoder. To avoid ambiguity, we will use “CLIP vision encoder.”
We understand the concern that intermediate ViT blocks have equal token counts and hidden widths. However, VDE combines selected intermediate ViT-B/32 representations with the separately projected final CLIP image embedding. The intermediate class-token features are 768-dimensional, whereas the final embedding is 512-dimensional. Thus, dimensionality differs across the complete branch set. We project every branch to 256 dimensions so that wider intermediate features do not receive greater fusion capacity merely because of width, the final embedding enters on an equal-dimensional basis, and the parameter count remains controlled.
“Uniformly spaced sampling” means approximately distributing selected blocks over depths 1–11, not sampling tokens. Block 12 is omitted because it is highly similar to the separately included final embedding. We evaluate (5,11), (3,7,11), (2,5,8,11), (2,4,6,8,11), and (1,3,5,7,9,11). Small shifts toward shallower blocks, such as 5 rather than 6 or 8 rather than 9 when 11/final are included, avoid over-concentration near the deepest endpoint.
4. Cross-depth fusion and performance
The final CLIP embedding is optimized as a compact global semantic representation for image–text alignment, but need not preserve all intermediate structural and perceptual information relevant to time-resolved brain signals. VDE therefore retains the final embedding and augments it with intermediate representations.
The bottlenecks equalize branch capacity before concatenation, and the residual MLP learns cross-depth interactions while producing a fixed-dimensional target. This controls parameter growth relative to raw 768/512-dimensional concatenation. The CLIP backbone is frozen; only lightweight projections and fusion layers are trained, reducing rather than increasing overfitting risk.
The results also argue against fusion merely adding noise: VDE raises Top-1 from 51.85 to 80.75 with BGE and from 48.98 to 77.10 without BGE. We do not claim universal superiority over attention fusion; the residual MLP is an intentionally simple, low-capacity choice for a few branches.
VDE is the larger contributor, but BGE also improves both visual settings, and their combination is best: 80.75 Top-1 versus 77.10 without BGE, 51.85 without VDE, and 48.98 without both. This supports their complementary effects.
5. Retrieval, reconstruction, and uncertainty
The main text already describes MEG performance and reconstruction as “competitive” or “comparable to state-of-the-art methods.” BRIDGE reports the highest Top-1/Top-5 for EEG intra-subject, EEG inter-subject, and MEG inter-subject retrieval. For MEG intra-subject retrieval, it remains comparable to BrainHiVE, with Top-1 0.6 points lower and Top-5 1.0 point higher.
We will soften overly broad state-of-the-art wording where necessary. Nevertheless, the results establish BRIDGE as a high-performing model across EEG/MEG and intra-/inter-subject settings.
For reconstruction, we use the BrainHiVE pipeline and could not reproduce its original values exactly; Table 13 therefore marks BrainHiVE† as our reproduction. Under the same pipeline, BRIDGE improves BrainHiVE† across all reported EEG metrics and most semantic MEG metrics, while other methods lead some measures. We therefore used “comparable to state-of-the-art methods” in the main text.
The revision will report subject-level mean ± SD and confidence intervals. For EEG intra-subject Top-1, BRIDGE obtains 80.75 ± 4.51 versus 75.68 ± 7.61 for BrainHiVE. Conclusions from four-participant MEG will remain cautious.
6. Early–shallow/late–deep evidence and neuroscience value
To examine the correspondence directly, we conducted RSA(representational similarity analysis) on three participants and the same 200 test stimuli. Values are mean Spearman correlations between neural-segment and visual-layer RDMs(representational dissimilarity matrix).
| Neural segment | hs2 | hs5 | hs8 | hs11 | final |
|---|---|---|---|---|---|
| Early | 0.1549 | 0.1919 | 0.1489 | 0.1200 | 0.1627 |
| Late | -0.0191 | 0.0018 | 0.0125 | 0.0008 | 0.0204 |
With hs2/hs5 defined as shallow and hs8/hs11/final as deep, early shallow-minus-deep similarity is +0.0295 and late deep-minus-shallow similarity is +0.0199. The hierarchical matching index is positive for all participants (0.0064, 0.0479, 0.0198). hs5 is the strongest early match for all three; the strongest late match is final for two and hs8 for one.
BRIDGE can support questions about whether representational geometry shifts from relatively perceptual toward more integrative information over time and whether time–depth tendencies replicate across participants. Following Van Essen and Gallant, region × time analysis can further examine whether visual pathways exhibit distinct temporal-depth profiles.
7. LDA and linear regression
Appendix G uses LDA only as a post-hoc visualization of separability under different temporal partitions; it is not the retrieval model. A multi-output linear regression could map flattened EEG directly to a visual embedding and perform cosine-similarity retrieval. However, it applies one fixed affine transformation to every sample and cannot learn nonlinear channel–time interactions or sample-dependent temporal weights.
Our “w/o BGE” variant is therefore a stronger and more competitive baseline than pure linear regression because it retains a nonlinear whole-window projector. Improving over this stronger baseline provides more convincing evidence for BGE than comparing only with a restricted linear mapper: full BRIDGE improves Top-1 from 77.10 to 80.75.
8. Meaning of zero-shot generalization
Here, “zero-shot” means that the 200 test concepts and paired brain recordings are absent from task-specific training. The frozen CLIP encoder provides a common visual space, but BRIDGE must learn from training concepts how to map EEG/MEG into that space and retrieve the correct image for concepts never paired with neural data during training.
Thus, the experiment evaluates generalization of the learned brain-to-vision alignment across concepts. Whether CLIP encountered related concepts during its pretraining does not remove this challenge, because the trainable brain encoder and fusion modules never observe paired neural examples from the test concepts.
9. Presentation
Because of the page limit, extended implementation details and subject-wise results were placed in the appendix. The revision will explain the most important settings, ablations, and conclusions more fully in the main paper.
Thank you for your thoughtful comments and for the time you have invested in our work. We have posted our response and hope the above clarifications and the additional experiments sufficiently addressed your concerns. If any questions remain unresolved, please let us know. We would be grateful to clarify further and are happy to discuss specific points.
- Rating
- 4/6
- Confidence
- 5/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This submission introduces BRIDGE (Brain-Vision Representation Integration through Depth and Granularity Encoding), a framework for decoding visual information from EEG and MEG. The paper is motivated by a mismatch between the temporal dynamics of neural responses and the predominantly static view of visual representations used by many existing brain-decoding approaches.
BRIDGE addresses this mismatch through two components. The Brain Granularity Encoder uniformly partitions the neural response into temporal segments, encodes each segment, and combines them through attention pooling. The Visual Depth Encoder extracts and combines representations from several layers of a frozen CLIP visual encoder. Brain and visual embeddings are aligned using a symmetric contrastive objective, supporting zero-shot image retrieval and brain-to-image generation.
The method is evaluated on THINGS-EEG and THINGS-MEG. It produces strong retrieval results. Ablation experiments indicate that both temporal partitioning and multi-depth visual features contribute to performance.
Strengths and weaknesses
The paper identifies a meaningful limitation of approaches that decode brain representations from a static pattern. Accounting for the temporal evolution of visual processing is well motivated by cognitive neuroscience. The combination of temporal neural factorisation, multi-depth visual representations, and contrastive alignment is intuitive and technically straightforward. Testing on both EEG and MEG broadens the empirical scope of the work. The inclusion of within- and between-participant evaluations is also valuable. The experiments separately examine the Brain Granularity Encoder, Visual Depth Encoder, number of temporal segments, and number of visual layers. These analyses generally support the architectural choices. The response window is divided uniformly, with two equal segments used by default. The manuscript does not state the corresponding post-stimulus time windows clearly. Consequently, it is difficult to interpret what these stages represent in terms of brain function or to assess the claim that they correspond to early perceptual and later semantic processing. Secondly, the framework does not explicitly align particular neural stages with particular visual depths. Temporal segments are pooled into one brain embedding, while CLIP layers are concatenated into one visual embedding. These global embeddings are then aligned with a global contrastive loss. Thus, the method uses information from multiple stages and depths, but it does not demonstrate a temporal-to-depth correspondence. Claims of hierarchical or biologically motivated alignment should therefore be qualified. Important experimental details are missing. The paper does not clearly report image-presentation duration, inter-stimulus interval, complete analysed epochs relative to stimulus onset, or the exact temporal boundaries produced by each segmentation setting. These details are essential for reproduction and interpretation. Additionally, the manuscript motivates the method using established temporal properties of visual processing but does not analyse what the model reveals about those processes. For example, it does not relate segment boundaries or attention weights to established event-related components or temporal phenomena such as the P1/P100, N170, N300/N400, or later components. It also does not show whether shallow CLIP features preferentially correspond to earlier neural activity and deeper features to later activity. Individual-difference handling needs clarification. The inter-participant procedure uses leave-one-participant-out evaluation together with participant-specific baseline subtraction based on a calibration set. The amount and nature of calibration data are not specified. It is therefore unclear whether the method generalises to a genuinely unseen participant without participant-specific data. The main tables report averages but no confidence intervals, standard deviations, or significance tests. Subject-level results are useful, but uncertainty across participants and training runs should be reported.
Questions
What were the image-presentation duration and inter-stimulus interval in THINGS-EEG and THINGS-MEG? What complete post-stimulus interval was provided to the model for each dataset? What are the exact boundaries, in milliseconds after stimulus onset, for the two-, three-, four-, five-, and six-segment settings? Were baseline or pre-stimulus samples included in any temporal segment? If so, how might this affect the learned representation? Why were uniform temporal partitions chosen instead of boundaries informed by known neural response latencies or learned directly from the data? Can the authors report the learned temporal attention weights across participants and stimuli? Are they consistent, and do they correspond to interpretable neural time periods? Is there direct evidence that earlier neural activity is better aligned with shallow CLIP layers and later activity with deeper layers? A temporal-segment-by-visual-depth similarity analysis would test the paper’s central hierarchical-matching hypothesis more directly.
Limitations
The manuscript shows improvements over previous attempts at decoding brain data. But how does uniformly dividing a response window into two halves improve decoding? How does one establish that the segments reflect early perceptual and later semantic processing? The model also collapses temporal and visual-depth information before applying the alignment objective, preventing direct interpretation of how particular neural time periods correspond to particular levels of the visual hierarchy.
Generalisation is evaluated on only two related THINGS datasets, with 10 EEG participants and four MEG participants. The MEG sample is particularly small, and both datasets use object-centred images drawn from the same broader stimulus resource. It remains uncertain whether the findings generalise to natural scenes, other tasks, different acquisition systems, different preprocessing pipelines, or datasets without extensive repeated trials.
The reported performance also depends on averaging repeated presentations of each image, including 80 repetitions for THINGS-EEG test images. This substantially improves signal-to-noise ratio but may limit applicability to realistic single-trial decoding. Single-trial performance, or performance as a function of the number of averaged repetitions, would provide a more informative assessment of practical utility.
Finally, between-participant generalisation appears to require participant-specific calibration for baseline subtraction. Until the calibration requirements and calibration-free performance are reported, the results should not be interpreted as demonstrating fully participant-independent decoding.
Formatting concerns
Table 9 contains placeholder entries (“xx.xx”), and the text refers to “Martin Cichy.” The researcher’s name is Radoslaw Martin Cichy, commonly referred to as Radek Cichy.
2 comments
Rebuttal
We thank you for your careful assessment and for recognizing the motivation, technical soundness, retrieval performance, and EEG/MEG evaluation of our work. Below, we address your concerns point by point and will incorporate the corresponding clarifications and analyses into the revised manuscript.
1. Multilevel integration and temporal partitioning
Thank you for raising this important concern. BRIDGE is motivated by the need to retain multilevel information in both modalities, rather than matching a whole neural response only to the final visual embedding. BGE exposes temporally ordered neural information, while VDE preserves the shallow-to-deep CLIP trajectory. Our main contribution is to make both perceptual and integrative information available for brain–vision alignment.
Neural latencies vary across participants and stimuli, making exact temporal-stage-to-visual-depth correspondence difficult to transfer. BRIDGE therefore fuses temporal stages and visual depths before contrastive learning, allowing information from different levels to jointly enter the shared space and produce an implicit hierarchical alignment, without requiring the same transition to occur at the same latency for every participant or stimulus.
We agree that many fine-grained issues remain unaddressed. Latency-informed or adaptive boundaries are valuable, but add choices or parameters that may overfit participant- and stimulus-specific fluctuations in low-SNR EEG. We preliminarily explored overlapping sliding-window attention, learnable soft temporal gates, and differentiable soft boundaries; all were more than 20 Top-1 percentage points below two-stage BGE without extensive dataset-specific tuning. Explicit stage-wise losses face a related difficulty because the correct assignment is unknown for each participant or stimulus, although both directions remain worthwhile.
The two-stage midpoint is neither a universal functional boundary nor necessarily the globally optimal split. It is a simple, robust setting: two-stage BGE improves the whole-window baseline from 75.70/94.60 to 78.87/96.15 Top-1/Top-5, whereas finer uniform partitions generally degrade; complete BRIDGE reaches 80.75/97.03.
To qualify the claims, we will replace:
“BRIDGE models the correspondence between neural dynamics and visual hierarchy at multiple representational scales.”
with:
“BRIDGE integrates temporally staged neural information and multi-depth visual information into a shared embedding for multilevel alignment.”
We will replace “a biologically motivated and information-preserving framework” with “a neuroscience-inspired and information-preserving multilevel integration framework.”
2. Stimulus timing and temporal boundaries
Thank you for this important question. THINGS-EEG presents each image for 100 ms, followed by a 100-ms blank interval (SOA: 200 ms). THINGS-MEG presents each image for 500 ms, followed by 1000 ± 200 ms fixation (SOA: 1500 ± 200 ms). BRIDGE uses the complete 0–1000 ms post-stimulus interval for both datasets; no pre-stimulus samples enter BGE. These details will be added to Sec. 4.1 and Appendix A.
| Segments | Nominal boundaries after onset (ms) |
|---|---|
| 2 | 0, 500, 1000 |
| 3 | 0, 333, 666, 1000 |
| 4 | 0, 250, 500, 750, 1000 |
| 5 | 0, 200, 400, 600, 800, 1000 |
| 6 | 0, 166, 332, 498, 664, 830, 1000 |
The boundaries provide only an ordered early-to-late factorization, not labels for specific brain functions. Integer sample indices are partitioned by floor division, with the final segment absorbing any remainder, as specified in Sec. 3.2. Different sampling rates and indivisible sample counts can therefore cause small deviations from the nominal millisecond boundaries.
3. Temporal attention consistency
Thank you for this important question. We analyzed two-stage EEG attention for Subjects 1–3 over the same 200 test stimuli.
| Subject | Early mean | Late mean |
|---|---|---|
| 1 | 0.0193 | 0.9807 |
| 2 | 0.6992 | 0.3008 |
| 3 | 0.6097 | 0.3903 |
| Across-subject mean | 0.4427 | 0.5573 |
To measure cross-participant consistency over stimuli, we correlated the early-stage weights assigned by each participant pair to the same 200 images. Spearman correlations are 0.2774 (S1–S2), 0.2740 (S1–S3), and 0.4018 (S2–S3), with all p<0.0001. Thus, an image receiving relatively greater early-stage emphasis for one participant tends to receive greater early-stage emphasis for another. This shows moderate, reproducible agreement in the relative stimulus ranking, despite different average allocations across participants. Because the two weights sum to one, late-stage correlations are nearly identical.
4. Temporal-segment-by-visual-depth correspondence
Thank you for this valuable suggestion. We conducted the requested analysis on the same three EEG participants and 200 stimuli. An RDM (representational dissimilarity matrix) records pairwise dissimilarities among stimuli. RSA (representational similarity analysis) is the Spearman correlation between the upper triangles of a neural RDM and a visual RDM; a higher positive value means that the two representations organize stimuli more similarly. Values are mean RSA across participants, with SD in parentheses.
| Neural segment | hs_2 |
hs_5 |
hs_8 |
hs_11 |
final |
|---|---|---|---|---|---|
| Early | 0.1549 (0.0174) | 0.1919 (0.0081) | 0.1489 (0.0133) | 0.1200 (0.0260) | 0.1627 (0.0261) |
| Late | -0.0191 (0.0399) | 0.0018 (0.0350) | 0.0125 (0.0478) | 0.0008 (0.0098) | 0.0204 (0.0039) |
With hs_2/hs_5 defined as shallow and hs_8/hs_11/final as deep, early shallow-minus-deep similarity is +0.0295, and late deep-minus-shallow similarity is +0.0199. We summarize both directions as
HMI = 0.5 × [(early-shallow − early-deep) + (late-deep − late-shallow)].
The Hierarchical Matching Index (HMI) is 0.0247 on average and positive for all participants (0.0064, 0.0479, 0.0198). A positive HMI means that the expected ordering—early/shallow and late/deep—is stronger than the crossed ordering. hs_5 is the strongest early match for 3/3 participants; the strongest late match is final for 2/3 and hs_8 for 1/3. This directly supports a coarse early-shallow/late-deep tendency while remaining compatible with global fusion.
5. Subject-dependent baseline subtraction
Thank you for raising this important concern. The inter-participant model uses leave-one-participant-out training, so no trainable parameter is optimized on the held-out participant. However, baseline subtraction estimates a static mean prototype from that participant’s unlabeled training/calibration split: 66,160 EEG trials or 22,248 MEG presentations. No evaluation trial is used.
We agree that this preprocessing is subject-dependent and does not demonstrate fully calibration-independent decoding. The revision will report the amount and nature of the calibration data, describe the prototype computation, and call the setting leave-one-participant-out evaluation with subject-dependent baseline subtraction. Calibration-independent normalization is important future work.
6. Statistical uncertainty
Thank you for this important question. The revision will report subject-level mean ± SD and, where appropriate, confidence intervals or paired tests. In EEG intra-participant Top-1, BRIDGE obtains 80.75 ± 4.51, compared with 75.68 ± 7.61 for BrainHiVE over the same ten participants. The paired gain is +5.07 points (two-sided Wilcoxon p=0.0059). BRIDGE therefore improves the mean while reducing across-participant dispersion. We will remain cautious about inference from the four-participant MEG dataset.
7. Evaluation scope and practical limitations
Thank you for raising these important limitations. We agree that the current evaluation cannot eliminate limitations concerning related object-centered datasets, four MEG participants, repeated-trial averaging, or subject-dependent preprocessing, and we will narrow the claims accordingly.
THINGS-EEG and THINGS-MEG are nevertheless standard large-scale benchmarks used by NICE, UBP, BrainHiVE, and related methods. THINGS-EEG contains 82,160 trials per participant, and THINGS-MEG contains 22,248 training presentations per participant, supporting controlled evaluation across EEG/MEG, intra-/inter-participant protocols, retrieval, and generation. To our knowledge, no other public benchmark currently offers the same combination of large-scale paired EEG/MEG recordings, shared stimuli, and established zero-shot protocols. Natural scenes, continuous viewing, other tasks, acquisition systems, and preprocessing pipelines remain important future tests.
Additionally, for generation, the vision-to-diffusion prior is trained on ImageNet-1K images. This reduces dependence of the visual prior on the evaluation stimulus resource, but does not itself establish neural-domain generalization.
The standard protocol averages 80 EEG or 12 MEG repetitions per test image, so the results assess relatively high-SNR representation quality rather than single-trial deployment. We will pursue single-trial, repetition-count, broader-dataset, and calibration-independent evaluations to reduce these limitations.
8. Formatting and naming corrections
Thank you for your careful review. We apologize for the incomplete Table 9 entries and naming inconsistency. All xx.xx placeholders will be replaced, and Radek Cichy will be used consistently.
Thank you again for your constructive comments. We hope our responses clarify your concerns, and we would be happy to address any further questions you may have.
Thank you for your thoughtful comments and for the time you have invested in our work. We have posted our response and hope the above clarifications and the additional experiments sufficiently addressed your concerns. If any questions remain unresolved, please let us know. We would be grateful to clarify further and are happy to discuss specific points.
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 4/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors combine two novel approaches to improve the alignment between features derived from static images, and features extracted from non-invasive brain imaging signal measured with two different modalities (EEG and MEG). First, they model the temporal properties of the neural signal by training a Brain Granularity Encoder (BGR) to embed temporally partitioned signal using a linear mapping, a residual MLP block and learnable MLP-style attention pooling. Second, they generate static image embeddings that combine low- (e.g., edges) and high-level (e.g., semantics) features using a Visual Depth Encoder (VDE) that projects and concatenates hidden representations extracted at multiple depths from a frozen CLIP backbone. The model performance is comparable with state-of-the-art approaches on brain decoding benchmarks and brain-to-image generation. Ablation experiments further demonstrate the value of modelling temporal granularity in the neural signal and depth in vision model representations to extract image-relevant information from brain activation.
Strengths and weaknesses
QUALITY: This high quality submission is technically sound, with clearly defined goals directly addressed by the experiments, and conclusions supported by the results. The choice of methods, experiments and tests addresses the problematic systematically, and the innovations introduced lead to a demonstrable improvement in model performance. The ablation studies test the article’s premise using two separate neuroimaging modalities, which provides additional robustness.
CLARITY: The manuscript is well structured, concise and easy to read. The methods’ formulas are particularly clear, the implementation is well detailed in the main manuscript and the code is provided as supplementary material with the stated intention of being shared openly following acceptance. The experiments are based on two open datasets which promotes reproducibility.
SIGNIFICANCE: The authors do a good job positioning their work within its current field, and explain clearly how it builds from and improves on previous brain decoding approaches. While the correspondence between vision ANN layer depth and levels of abstraction in the brain’s visual system are well documented, the article proposes an elegant approach to exploit this knowledge, and the results demonstrate how this innovation improves performance on relevant benchmarks. With the methods’ descriptions and scripts and dataset availability, these innovations can easily be implemented in other people’s work.
ORIGINALITY: The article positions its innovations clearly within the existing literature, with relevant recent citations from 2023-2026. The authors explain how their innovation builds on existing implementations, and provide a clear rationale for it. Mainly, the work introduces an intuitive manner to bridge a gap between two modalities. It relies mostly on existing ML techniques, but is inspired by known properties of the brain signal, which it models in a novel and clever way to improve the alignment between multi-layered features learned from static images, and representations learned from brain dynamics. The implementation is practical, informed and relevant to the previous work that it builds upon.
Questions
-
I have one point of uncertainty about the description of the THINGS-MEG benchmark. In section A.2, the authors say (line 529): “we use the standard zero-shot split in which the training set contains 1,854 concepts with 12 images per concept and the test set contains 200 held-out concepts with 1 image per concept repeated 12 times”. From what I understand of the THINGS image data bank, it samples a total of 1,854 object concepts. The THINGS-MEG1 dataset includes 200 test images shown multiple times to each participants, but unless I misunderstood the data paper’s description (https://doi.org/10.7554/eLife.82580), these test 200 images were drawn among the main 1,854 concepts. Specifically, the test set included 200 held-out images but not 200 held-out concepts: there were no “test concepts” (line 227). In other words, the THINGS-EEG benchmark assesses generalization across held-out concepts, but the THINGS-MEG benchmark does now. Results should be interpreted and conclusions should be drawn accordingly.
-
The authors report improved decoding after splitting the brain signal into an early and a late phase. Among the limitations they report, they mention their model’s uniform temporal partitioning. I’m wondering whether the authors also considered the brain’s spatial organization in their modelisation. Both the MEG and EEG signal they model has wide cortical coverage. Did they explore the alignment between embeddings based on different depths of CLIP layers, and signal from different brain regions (e.g., from the ventral visual pathway)?
Classic work by Uri Hasson has identified a hierarchy of temporal receptive windows that vary in durations across the brain (e.g., during narrative processing; https://doi.org/10.1523/JNEUROSCI.5487-07.2008). With a more flexible framework where temporal partitioning is learned adaptively, it might be informative to explore whether temporal partitioning can be optimized differently across brain regions. As a first step, it would be interesting to explore whether optimal temporal partitioning differs depending on the spatial composition of the brain signal, perhaps with an ablation study.
-
Consistent with each respective benchmark, decoding was noticeably better for experiments conducted with EEG compared to MEG. I’m wondering whether the authors could address this discrepancy in their discussion. I’m also curious why no reconstructed images were shown for the MEG data (only the reconstruction metrics listed in tables 13 and 15). Was the reconstructed image quality much poorer than for reconstruction from EEG? Is there something fundamentally superior about EEG signal, either in terms of noisiness, coverage or resolution, that would account for this massive discrepancy in performance?
-
The proposed approach is designed to improve the alignment between dynamic brain signal and static image embeddings, notably by capturing different phases of the neural response to image viewing. Under more naturalistic viewing conditions where the flow of visual stimuli is in constant flux, for example during movie watching, would the authors still expect temporal partitioning to lead to decoding gains? Would they anticipate a similar number splits (2) to still be optimal in this scenario?
-
I have a few suggestions to improve clarity and style:
- I would like to see Figure 1 enlarged, and I’m a bit concerned by the asymmetry of the grey brain icons in Figure 1 (the left hemisphere looks swollen...).
- I would revisit the choice of acronyms that refer to the different model components: both the Visual Depth Encoder and the Visual Decoding Encoder (introduced in section 3.5) share the VDE acronym. Same concern with the Brain Granularity Encoder and the Brain Generation Encoder (section 3.5) (BGE). May I recommend using different sets of acronyms to disambiguate these important model parts?
- the authors acknowledge their use of LLMs to improve the clarity of the writing. If I may, I noticed an over-reliance on adverbs ending in “ly”. E.g., I counted 5 in the sentence starting on line 56. Less is more?
- I suggest decapitalizing the V in Brain-Vision Representation Integration through Depth and Granularity Encoding for the acronym to work (BRIDGE).
- line 56: “to better adaptively extract brain signals” could read “to extract brain signals more adaptively”
- line 110: should “Martin Cichy” read just “Cichy”
- line 544: “the weight decay 0.5 for” seems to miss a word
Limitations
yes
Formatting concerns
None
2 comments
Rebuttal
We sincerely thank you for your careful, constructive, and highly positive assessment. We are encouraged that you find BRIDGE technically sound, clear, reproducible, and potentially useful. Below, we address all of your questions and describe the revisions we will incorporate into the manuscript.
1. THINGS-MEG split and interpretation
Thank you for pointing this out. In THINGS-MEG, the 200 repeatedly presented evaluation images originate from the overall bank of 1,854 THINGS concepts. Following the BrainHiVE/UBP preprocessing protocol used in our experiments, however, all training images belonging to these 200 evaluation concepts are excluded. The effective split is therefore 1,654 training concepts and 200 concept-disjoint evaluation concepts, rather than 1,854 training concepts plus 200 additional test concepts. We will correct Sec. 4.1 and Appendix A.2/A.3 accordingly. All reported results were already obtained using the 1,654/200 split and therefore remain unchanged.
2. Spatial organization and region-dependent temporal structure
Thank you for this important suggestion. Given the limited rebuttal period, we conducted a preliminary sensor-space investigation to determine whether the temporal correspondence with different CLIP depths varies across the spatial composition of the EEG signal.
We selected three THINGS-EEG subjects spanning high, middle, and low retrieval performance (S10: 85.7%, S4: 74.7%, and S5: 66.8% Top-1). For each subject, we used the same 200 repetition-averaged test stimuli and pre-encoder EEG. The 17 posterior electrodes were divided into two disjoint sensor groups: O/PO (PO7, PO3, POz, PO4, PO8, O1, Oz, O2) and P (P7, P5, P3, P1, Pz, P2, P4, P6, P8). Neural representational dissimilarity matrices were computed in 100-ms windows with a 50-ms stride over 0–800 ms and compared through Spearman RSA with shallow CLIP representations (L2/L5) and deep representations (L8/L11/final).
| Sensor group | 0–200 ms: shallow / deep RSA | 200–400 ms: shallow / deep RSA | 400–800 ms: shallow / deep RSA | Sustained shallow→deep crossover |
|---|---|---|---|---|
| O/PO | .161 / .089 (3/3 shallow) | .113 / .094 (3/3 shallow) | .027 / .031 (comparable) | 350–400 ms |
| P | .089 / .064 (3/3 shallow) | .058 / .084 (3/3 deep) | .014 / .027 (3/3 deep) | 150–200 ms |
Both groups favor shallow CLIP representations during 0–200 ms. They then show different temporal trajectories: P sensors exhibit a consistent deep-representation advantage from 200–400 ms onward, whereas O/PO sensors retain a shallow advantage during 200–400 ms and become approximately balanced later. The sustained shallow-to-deep crossover therefore occurs earlier for P sensors (150–200 ms) than for O/PO sensors (350–400 ms), consistently across subjects with different decoding performance.
These preliminary results support the reviewer’s hypothesis that optimal temporal modeling may depend on the spatial composition of the signal. We will include this analysis. Future work will extend this investigation to more subjects, MEG, finer spatial definitions, and spatially conditioned adaptive temporal partitioning.
3. EEG–MEG discrepancy and missing MEG reconstructions
Thank you for raising this important point. We agree that this discrepancy merits clarification, but we do not interpret it as evidence that EEG is fundamentally superior to MEG. The reported results come from different benchmarks rather than a controlled modality comparison. THINGS-EEG includes 10 participants and 80 repetitions per evaluation image, whereas THINGS-MEG includes 4 participants and 12 repetitions. The datasets also differ in stimulus-presentation and acquisition intervals, sensor configuration, preprocessing, dimensionality, and effective signal-to-noise ratio after repetition averaging.
Moreover, the current architecture and hyperparameters were transferred across modalities with limited modality-specific adaptation. EEG and MEG have different spatial and statistical characteristics; consequently, their optimal temporal window, normalization, input projection, encoder capacity, and spatial modeling strategy may differ. In particular, the compact 17-channel EEG input is well matched to our current encoder, whereas MEG may benefit from parameter and implementation adjustments tailored to its acquisition interval and sensor geometry. The same EEG–MEG gap is also observed in prior methods (e.g., BrainHiVE: 75.7% vs. 33.7%; UBP: 50.9% vs. 26.7% intra-subject Top-1), indicating that it is not specific to BRIDGE.
We apologize that MEG reconstruction examples were omitted during figure preparation. Although their average quality is lower than that of EEG reconstructions, several MEG reconstructions still preserve recognizable visual content. We will add MEG reconstruction examples in the revision.
4. Naturalistic continuous viewing
Thank you for this thoughtful question. Movie viewing involves a substantially different dynamic mechanism from the current THINGS protocol. THINGS presents isolated, stimulus-locked images, whereas movie frames change rapidly and continuously. Responses to consecutive frames overlap and incorporate motion, short-term context, event continuity, and information accumulated from preceding frames. Therefore, naturalistic decoding is a different task and will likely require a different temporal modeling strategy; we would not assume that the same two equal segments remain optimal.
Nevertheless, the central principle of BGE may remain beneficial: dividing the neural signal into multiple temporal components can preserve distinctions between shallow-feature-related and deep-feature-related information that may be obscured by whole-window encoding. Under rapid frame transitions, a two-stage representation may still provide a useful coarse decomposition while avoiding unstable, overly fine segmentation, but this requires direct experimental validation.
For movie data, we would adjust the input-window duration and the two subwindow lengths according to the frame rate and decoding target. Overlapping or frame-aligned windows could also be considered. We will clarify that two-stage partitioning is empirically effective for the current event-locked benchmarks, while its effectiveness and optimal window duration under continuous viewing remain to be evaluated.
5. Clarity and style
Thank you for these helpful presentation suggestions. We will implement them together. We will enlarge Fig. 1 and replace the asymmetric brain illustration, revise the title capitalization so that the BRIDGE acronym is unambiguous, reduce unnecessary adverbs and verbose constructions, apply the suggested wording and grammar corrections, and use Brain Granularity Encoder (BGE) and Visual Depth Encoder (VDE) consistently throughout the retrieval and generation descriptions. We will also conduct a complete terminology and proofreading pass.
We again thank you for these thoughtful comments. We would be happy to address any further questions you may have.
Thank you for your thoughtful comments and for the time you have invested in our work. We have posted our response and hope the above clarifications and the additional experiments sufficiently addressed your concerns. If any questions remain unresolved, please let us know. We would be grateful to clarify further and are happy to discuss specific points.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Dear Area Chair and Senior Area Chair,
We thank you and the reviewers for the careful evaluation of BRIDGE. We summarize the recognized strengths, concerns, and evidence added during rebuttal.
Strengths Recognized by the Reviewers
Reviewer-Specific Concerns and Responses
Overall Rebuttal Progress
The rebuttal adds MEG ablations, temporal-depth and sensor analyses, adaptive-partition comparisons, generation-specific VDE ablation, and cross-backbone validation, while correcting the THINGS-MEG split, clarifying key experimental details and restating our contribution and novelty.
Together, these results support the complementary contributions of VDE and BGE across EEG and MEG. We also clarify that precise temporal boundaries, region-specific modeling, and adaptive segmentation remain future directions.
We respectfully ask that the complete rebuttal evidence be considered in the final decision.
Thank you for your time.
Best regards,
The Authors