sMCC40M: A Context-Aware Dataset and Benchmark for Single-Cell Spatial Transcriptomics
Xi Li, Yaqi Hu, Ziheng Duan, Xinyi Wang, Simon Dongbo Sun, Diptanshu Sikdar, Yang Liu, Jing Zhang
NeurIPS 2026
Abstract. Spatial transcriptomics enables testing whether tissue morphology can predict molecular state, but existing benchmarks are constrained by limited scale, spot- level supervision, and incomplete biological context. We present sMCC40M, a mul- timodal resource comprising 38.47 million gene-positive cell/nucleus observations from 124 acquisitions across 23 tissue categories and seven species. Visium HD contributes 13.66 million observations and Xenium 24.81 million. H&E-pairing eligibility is recorded separately. Three data-centric axes assess generalization beyond local interpolation. First, sMCC40M provides scale: broad organ and study coverage enables controlled encoder benchmarking and reveals a scaling trend in which larger pathology foundation models improve morphology–gene correspondence under matched evaluation. Second, sMCC40M provides resolution: by decomposing assays into aligned cell-level records, our framework converts spot-level histology–omics pipelines into single-cell predictors and evaluates them under strict in-domain and cross-acquisition splits. Third, sMCC40M provides rich context: each cell is paired with spatial, molecular, and sample-level metadata, al- lowing analyses such as age-band shift in ovarian samples, where age-mismatched transfer sharply reduces prediction quality despite misleading global-distance sum- maries. Together, sMCC40M establishes a practical framework for single-cell histology-to-gene prediction while showing that robust generalization still depends on scale, cellular resolution, and explicit biological context.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 4 reviews · OpenReview
Updated 25 Nov 2026, 03:44 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper has received mixed, borderline reviews and, at this stage, the final decision could reasonably move toward either acceptance or rejection. The authors should use the rebuttal to directly address the key technical concerns raised by the reviewers, clarify any misunderstandings, and provide evidence supporting the paper’s main claims where possible.
The Area Chair will closely follow the rebuttal discussion and subsequent reviewer engagement. The final recommendation will depend significantly on whether the authors can resolve the central concerns and whether the reviewers find the responses convincing.
Final justification
The paper received generally positive reviews, with the main concerns focusing on whether the dataset is truly single-cell, its novelty and scale, the breadth of evaluation, and the validity of the derived Visium HD targets. The authors addressed these concerns through clarifications and substantial additional analyses, including distinguishing native cell-resolved from derived cell-aligned data, auditing overlap with prior datasets, expanding evaluation to all 25 categories and cross-sample settings, and adding a 9,000-polygon robustness analysis for Visium HD.
Overall, the rebuttal satisfactorily addressed the major concerns, and I recommend acceptance.
Before publication, the authors should also correct the three problematic references identified by the citation checker. Note that PCs/ACs may reject papers with 2 or more hallucinated references.
List of Problematic References with Reasoning
@article{zhao2021bayesspace,
author = {Eric Zhao and others},
title = {Bayesspace enables the robust characterization of spatial gene expression architecture in spatial transcriptomic data},
journal = {Nature Biotechnology},
year = {2021}
}
The citation contains critical errors in author name and title: 1) The first author is Edward Zhao, not Eric Zhao. 2) The paper published in Nature Biotechnology (2021) is titled 'Spatial transcriptomics at subspot resolution with BayesSpace'. 3) The title provided in the BibTeX entry is a modified version of the bioRxiv preprint title ('BayesSpace enables the robust characterization of spatial gene expression architecture in tissue sections at increased resolution').
@article{jones2022tabula,
author = {Rachael C Jones et al.},
title = {The tabula sapiens: A multiple-organ, single-cell transcriptomic atlas of humans},
journal = {Science},
year = {2022}
}
The citation contains an incorrect author name. The author is listed as 'Rachael C Jones', but the actual author is Robert C. Jones (along with The Tabula Sapiens Consortium et al.) for the paper titled 'The Tabula Sapiens: A multiple-organ, single-cell transcriptomic atlas of humans' published in Science in 2022.
@inproceedings{shao2021transmil,
author = {Zehui Shao and Hao Bian and Yaoqi Chen and Yao Wang and Jian Zhang and Xiangyang Ji},
title = {Transmil: Transformer based correlated multiple instance learning for whole slide image classification},
booktitle = {NeurIPS},
year = {2021}
}
While the paper title ('TransMIL: Transformer based Correlated Multiple Instance Learning for Whole Slide Image Classification') and venue (NeurIPS 2021) match an existing publication, the author list contains several hallucinated names: 'Zhuchen Shao' is incorrectly listed as 'Zehui Shao', 'Yang Chen' as 'Yaoqi Chen', 'Yifeng Wang' as 'Yao Wang', and co-author 'Yongbing Zhang' is omitted.
Read meta-review
Meta-review
The paper has received mixed, borderline reviews and, at this stage, the final decision could reasonably move toward either acceptance or rejection. The authors should use the rebuttal to directly address the key technical concerns raised by the reviewers, clarify any misunderstandings, and provide evidence supporting the paper’s main claims where possible.
The Area Chair will closely follow the rebuttal discussion and subsequent reviewer engagement. The final recommendation will depend significantly on whether the authors can resolve the central concerns and whether the reviewers find the responses convincing.
Final justification
The paper received generally positive reviews, with the main concerns focusing on whether the dataset is truly single-cell, its novelty and scale, the breadth of evaluation, and the validity of the derived Visium HD targets. The authors addressed these concerns through clarifications and substantial additional analyses, including distinguishing native cell-resolved from derived cell-aligned data, auditing overlap with prior datasets, expanding evaluation to all 25 categories and cross-sample settings, and adding a 9,000-polygon robustness analysis for Visium HD.
Overall, the rebuttal satisfactorily addressed the major concerns, and I recommend acceptance.
Before publication, the authors should also correct the three problematic references identified by the citation checker. Note that PCs/ACs may reject papers with 2 or more hallucinated references.
List of Problematic References with Reasoning
@article{zhao2021bayesspace,
author = {Eric Zhao and others},
title = {Bayesspace enables the robust characterization of spatial gene expression architecture in spatial transcriptomic data},
journal = {Nature Biotechnology},
year = {2021}
}
The citation contains critical errors in author name and title: 1) The first author is Edward Zhao, not Eric Zhao. 2) The paper published in Nature Biotechnology (2021) is titled 'Spatial transcriptomics at subspot resolution with BayesSpace'. 3) The title provided in the BibTeX entry is a modified version of the bioRxiv preprint title ('BayesSpace enables the robust characterization of spatial gene expression architecture in tissue sections at increased resolution').
@article{jones2022tabula,
author = {Rachael C Jones et al.},
title = {The tabula sapiens: A multiple-organ, single-cell transcriptomic atlas of humans},
journal = {Science},
year = {2022}
}
The citation contains an incorrect author name. The author is listed as 'Rachael C Jones', but the actual author is Robert C. Jones (along with The Tabula Sapiens Consortium et al.) for the paper titled 'The Tabula Sapiens: A multiple-organ, single-cell transcriptomic atlas of humans' published in Science in 2022.
@inproceedings{shao2021transmil,
author = {Zehui Shao and Hao Bian and Yaoqi Chen and Yao Wang and Jian Zhang and Xiangyang Ji},
title = {Transmil: Transformer based correlated multiple instance learning for whole slide image classification},
booktitle = {NeurIPS},
year = {2021}
}
While the paper title ('TransMIL: Transformer based Correlated Multiple Instance Learning for Whole Slide Image Classification') and venue (NeurIPS 2021) match an existing publication, the author list contains several hallucinated names: 'Zhuchen Shao' is incorrectly listed as 'Zehui Shao', 'Yang Chen' as 'Yaoqi Chen', 'Yifeng Wang' as 'Yao Wang', and co-author 'Yongbing Zhang' is omitted.
- Rating
- 5/6
- Confidence
- 5/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The work presents a database of 23+ million cell-aligned transcriptomics samples along with an initial study that appears to be focused on three of the twenty-five organs included in the database: mouse brain, cancerous human lung, and human ovary. Each cell's data includes a cell crop, a larger-field contextual crop, gene expression data from nearby spot transcriptomics, and patient metadata. The purpose of the aligned-cell database is to move in the direction of single-cell gene expression prediction.
Strengths and weaknesses
A narrative format is assumed; paragraphs are numbered simply to aid the authors in refering to specific sections of the review in their their rebuttal.
P1. The paper takes on a worthy and challenging goal: single-cell transcriptomics. The cell-aligned dataset compiled for this study is a good approach towards this goal. As the authors suggest, regional spot analysis does not have a mechanism for modeling the reality that different cells within a spot regions may be expressing significantly different sets of genes. By including an image centered and primarily cropped to a single cell, with a second image providing a larger context also centered on that cell, the database focuses in on the single-cell transcriptomics goal.
P2. Yet the larger question remains unanswered: Since all of the datasets provide spot-level gene expression data, and thus ground truth is only available at the spot level or some interpolation of it, how can we determine if a method is properly predicting the gene expression of the single cell shown in the transcriptions? It is conceivable that large models trained at scale could learn some sort of super-resolution modeling of gene expression. But the paper does not address this question. So the dataset (and the baseline experiments that accompany it) are single-cell on the imaging side, but not on the gene expression side.
P3. The baseline experiments appear to be incomplete. As mentioned in the summary, the experiments within the main paper clearly focus on three organ types: mouse brain, cancerous human lung, and human ovary. While there are additional experiments that do not mention specific organs, such as those used to produce figures 2b and 2c, it is not clear whether these are evaluated across all 25 organs or only on the two organs shown in figure 2a and discussed elsewhere in the section.
P4. While the ovarian experiment highlights the importance of metadata and the dangers of out-of-distribution deployment of models, it does not help to move the paper towards true single-cell analysis.
The remarks above explain my ratings in the quality, significance, and originality ratings. Now considering the clarity rating:
P5. The paper is generally free of typographical and grammatical errors (though the figures, especially Figure 1, contain a rather large number of these). Nevertheless, the writing style appears to occasionally slip needless remarks. The main body of the paper also reiterates the main themes from the introduction several times. While such anchoring can be helpful, it feels like the paper could be made more clear by including more details within the main body of the paper at the expense of removing some of this redundancy. Examples of these are included below.
P6. Examples of detail that could be moved into or enhanced in the main body of the paper include: (1) A breif summary of how closely the spot centers align with the cell centers. (2) Many other details of the cell alignment procedure: a) What algorithms are used to find cells when the scanner or existing datasets do not provide these? b) Have these algorithms been previously validated and are they reliable at finding cells?
P7. The term STBoost is used in the abstract and again used for the first time in the paper in Section 3.3. In neither place is the term defined -- it is only in Section 4.2 (line 204) that the paper says "we introduce STBoost" and defines it. Please use such language both in the abstract and in the introduction, where STBoost can be introduced as one of the contributions of the paper. For example, on line 57, you could say, "Second, it defines a data-centric framework, STBoost, for lifting..."
P8. It would be good to clearly specify how many patients and animals are included in the study, including, for the cross-patient splits, how many patients are in the the training set and how many are in the testing set. Including this figure alongside cell counts helps to establish the scale of the dataset.
FURTHER MINOR REMARKS
Paragraph 5 above mentions typographical errors and textual excesses. Here are some specific examples of these:
Figure 1:
hierarchical -> Hierarchical (letter case issue)
Resolutio(Single -> Resolution (Single (missing letter and space)
There are some blanks in this figure that could be filled in, e.g. under "LLM Agent"
This figure feels AI-generated. If it is manually re-cast with, e.g. Inkscape and adjusted, I think the overall clarity could be improved.
The caption could also add more text explaining the parts of the figure up front.
Table 1: Clarify what "study split" means in the text referring to this table, with a forward reference to the appendix that describes the splits in detail
Table 2: Clarify what "cell unit" means in the text referring to this table, again, with a forward reference to the section(s) that define these different cell units in more detail.
Figure 2 b), horizontal axis: Define what ratio is being used both here and in the text referring to this figure
Figure 3: Eliminate the thin partial border around the top left of the figure. Render text as text rather than as a rasterized image
Line 107 cut "but the dataset itself must be introduced first" and shorten related text.
Line 115 cut "kept" and "rather than used as a main text claim"
Line 268 cut "rather than only as a descriptive dataset." Also clarify within this sentence that "We release part of sMMC-22MBench" rather than the whole dataset. Although the final paper should describe more clearly exactly which parts of the dataset are publicly available at the time of publication.
P9. Please note that it is not safe to assume that existing datasets are representative of ethnic, gender, or other human traits that could disadvantage minorities underrepresented in the data. Performing a metaanalysis, where possible, of the gender and ethnic balance of the dataset adds to the paper.
Questions
Q1. If you have trained and tested on all 25 organs, please provide summary performance and per-organ performance information in the main body of the paper.
Q2: Please seriously consider removing "Single-cell" from the title and "single-cell predictors" from the abstract or exclusively couch such terms in expressions like "moving towards single-cell predictions."
Q3. Consider whether it is feasible to compare cell-aligned performance with spot performance. If cell-aligned performance could be shown to have significantly higher transcriptomic prediction accuracy than spot centered methods, this could be an argument that we are indeed nearing single cell predictions.
Q4. Consider describing clearly in the main body of the paper what techniques were used to interpolate or match spot-level gene expression to individual cells.
Q4. Consider renaming sMMC-22M to sMMC-23M or whatever the proper cell count is at the time of publication.
Limitations
L1. The core limitation that I have described earlier (e.g. in P2 and in Q2.) is that the method claims to have single-cell predictions yet don't have experiments that back this claim. The first sentence of the Limitations section acknowledges this concern, but replaces it with a vague "stronger evaluation" contribution:
Line 283: The value of sMMC-22M lies in enabling stronger evaluation, not in implying that histology-to molecular prediction is solved.
L2. The second sentence of limitations appears to move on to a different topic:
Line 284: "Scale improves morphology–gene correspondence, but the scaling-law results do not remove the need for leakage-controlled biological transfer tests."
It is unclear to me whether the paper claims (e.g. with the carefully defined splits included as part of the dataset) to solve the biological transfer tests) or whether this is a further indirect acknowledgement that the current work does not align the single cells with cell-specific gene expression.
L3. The third sentence of the limitations section is the most confusing to me:
Line 285: "Cell-level resolution makes the task more biologically meaningful, but it also exposes errors that spot-level averaging can hide."
What errors does the current work expose that spot-level averaging can hide? I can't think of which experiment in the paper this may refer to, or to discussion earlier in the paper on any errors exposed in spot-level averaging.
L4: Lines 287-288 acknowledge that various forms of information are missing from the public datasets from which the proposed dataset is derived. A summary of coverage across organs, patients and animals, of where alignment and metadata are satisfactory (or how satisfactory they are in different portions of the dataset) would provide a modest strengthening of the paper. This is related to Q1.
Final justification
I appreciate the authors' persistent, patient replies during the review period. At this point, all my major concerns are resolved.
My one, minor, remaining concern is whether the authors can revise their manuscript, remove all typos, and present a clean manuscript that clearly conveys all the strengths of their work. In an effort to enable this, I will try to summarize here, in order of importance, what I hope they can make clear in their final manuscript.
- This is truly a single-cell expression prediction work. The authors do NOT need to change the title from the original submission, except to update the number of cells to accurately reflect the version of the dataset published with the work. Both in my original review and through much of the discussion, I was confused on this point. But now I'm convinced it truly is a single-cell gene expression prediction dataset. So I believe the original title, "sMMC-22M: A Context-Aware Dataset and Benchmark for Single-Cell Spatial Transcriptomics", needs only be updated to "sMMC-23M: A Context-Aware Dataset and Benchmark for Single-Cell Spatial Transcriptomics" (or whatever number of cells is included in the final released version.)
The authors made it clear that the dataset is truly a single-cell expression dataset in this response:
It contains three major data sources: Xenium, our in-house DBiT datasets, and Visium HD. Both the Xenium data and the in-house DBiT data provide genuine single-cell measurements. The Visium HD portion is generated by aggregating 2 μm bins to segmented cells.
I am not an expert on this point but I believe that 2 μm bins are at higher resolution than cells and so the authors can reasonable claim that aggregating them to nearby cell-centers is truly also a way of determining single-cell expression. If this is true, simply summarizing this early in the paper, and making the edits to avoid terms like "lifting" should bring much more clarity to this critical point.
Also important to this point is the comparison with related works that the authors shared with another reviewer. This should be included in the main paper text.
- It is good to see the authors emphasizing, under the key points of scale and single-cell prediction benchmark that they have performed initial experiments on all organ categories in a "25-category organ benchmark." It will be important to include both the table and the description of the experiment within the main paper body.
Although it is disappointing that these experiments do not show transfer from one patient to another, the database is still a unique contribution to single-cell transcription prediction for the physically-separated 2/3 training, 1/3 testing experiments done within the same tissue sample. Hopefully the completion and publication of this work will inspire further datasets in this area that will enable cross-patient predictions.
-
The authors have clearly answered all my questions about the format of the data to be released. The example data shared in the reviewer sample is now in the same format they describe. Please do clearly specify how position_in_tissue should be interpreted -- can it be used to determine where the cell is found within the larger patch.tif?
-
If the authors need room in the manuscript, I think it would be OK to relegate the ovarian cancer experiment to an appendix. Since this on only a single organ, it is not essential to the first two points which are sufficient for a work like this.
-
Please try to fix all the typos, especially in the figures. Please see my original comments about typos for this.
Formatting concerns
No concerns in this area.
18 comments
Thank you for retitling the work
I think the new title, "sMMC: A Cell-Aligned Multimodal Resource for Spatial Transcriptomics", fits the work FAR better than the old one. This change alone greatly improves my opinion of the work.
Thank you very much for your encouraging feedback. We are delighted that you feel the revised title better reflects the scope and contribution of our work. We will use this revised title in the final version. If you feel that our rebuttal and revised framing have addressed your main concerns, we would be grateful if you might consider updating your overall evaluation.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper presents a large-scale paired spatial transcriptomics + histology resource together with a benchmark and an accompanying model (STBoost). The authors frame three contributions: (1) increasing the scale and diversity of paired ST–histology data, in part by adding in-house data on top of existing collections of public 10x Genomics data (Xenium & Visium HD), (2) pushing the data to cell-level resolution and enriching each record with biological/textual context, yielding per-cell multimodal records, and (3) an empirical study organized along these three axes (scale, resolution, rich context).
Strengths and weaknesses
Strengths: Paired ST-histology data at scale is genuinely scarce and valuable, so the overall direction is worthwhile. Organizing the resource and its evaluation along three axes (scale, resolution, biological context) is a reasonable framing, and the ambition to move from spot-level toward cell-level, multimodal records is well motivated in principle. If the in-house data are substantial and the full resource and pipeline are released, this could be a useful community asset.
Weaknesses:
- My main concern is that, while I understand how scale, resolution, and rich context were incorporated into the dataset, it is unclear what the experiment for each axis is actually meant to show i.e., whether the benchmark poses biologically meaningful questions or establishes that each axis yields measurable scientific value. A benchmark should define a biologically meaningful task, explain why that task matters, and compare the performance of multiple methods that can address it; this paper is substantially lacking in both the rationale for, and the clarity of the experimental design behind, each of its experiments.
- The new data are largely derived or generated rather than measured, and the paper does not validate them. The cell-level expression appears to come from bin2cell, i.e., a computational decomposition of spot-level signal, and the rich textual context appears to be LLM/LMM-generated, but the paper does not validate it: there is no factuality or human evaluation of the generated text, no description of the generation pipeline in the main text (it only appears in Figure 1), and no example records shown.
- The magnitude of the in-house contribution is also not quantified. It is unclear how many samples/cells/tissues are added relative to HEST-1K and STimage-1K4M, which makes the "scale" claim hard to assess.
- The cell-level profiling relies on bin2cell, a well-known existing tool, so the methodological novelty of the spot→cell component is weak. Spot-to-cell expression inference also appears to be an approach that has been extensively explored in prior work, but the paper does not position itself against this in related work. An explanation of the idea behind the spot→cell construction should appear before the downstream experiments.
- Clarity. This is a pervasive problem and it limited my ability to assess the claims. • Figure 2 / scale: the task is not stated (is it image→gene-expression prediction?), the metric is unclear, and the motivation for the experiment is missing. Whether a scaling law is actually demonstrated is unclear. • STBoost / resolution: the model's inputs and outputs are not clearly specified in the main manuscript. At inference, does it take only histology and output cell-level expression, or does it also use spot-level expression? The relationships among STBoost-Ref, "Ours" in Figure 4, and "STBoosted BLEEP" are not explained, and BLEEP itself (the baseline) is never introduced. The evaluation protocol, the ground truth used, and the actual conclusion of the resolution study are hard to extract. • I don’t get what Table 2 explains at all. Please clarify. • Rich context / age effect: the abbreviations AK and AD are never defined. • There is substantial redundancy — the scale/resolution/rich-context story is repeated many times, while the concrete experimental descriptions that readers actually need are thin.
Questions
- In-house data scale. Please quantify precisely how much new in-house data is contributed relative to HEST-1K and STimage-1K4M (samples, tissues, platforms, spots/cells), ideally as a comparison table. What fraction of the resource is genuinely new vs. aggregated?
- Clear purpose and biological meaning of the per-axis experiments. For each experiment, please lay out the benchmark objective, design, results, and significance cleanly. In particular: • What task and metric does Fig. 2 use? • In the resolution study, what exactly are STBoost, STBoost-Ref, and "Ours"; what is BLEEP; and what is "STBoosted BLEEP"? • For the age-effect analysis, what is the precise claim, and why is it informative beyond the expected degradation under an age shift?
- Validation of generated data. How are the bin2cell-derived cell-level profiles and the LMM-generated textual records validated? Please describe the generation pipeline in the main text and show representative example records.
Limitations
No. The paper does not address (a) the rationale and biological significance of its benchmark experiments, (b) validation of its generated cell-level profile and textual data, or (c) data accessibility/reproducibility.
Final justification
Given short period of time, authors have addressed most of my comments. I'd like to change my score to 4.
Formatting concerns
• References appear to be uniformly truncated to "et al." in the bibliography. Please verify this matches the required citation style and lists authors as specified. • Several dataset links (in Appendix) appear inaccessible / the full dataset does not seem viewable.
5 comments
Rebuttal
We thank the reviewer for identifying places where the manuscript did not sufficiently distinguish primary measurements, derived cell-aligned targets, and generated auxiliary fields, or explain the objective of each experiment. We provide the requested quantitative audit, expanded results, and validation below. We will revise the manuscript point by point following the reviewer’s suggestions, and hope the reviewer will reconsider the paper after seeing these changes.
Q1. Precisely quantify new in-house data versus HEST-1K and STimage-1K4M by samples, tissues, platforms, cells, and new-versus-aggregated fraction.
A1. We agree. We audited every sample against HEST-1K v1.1.0 and the 2025-02-12 STimage-1K4M snapshot.
| Category | Slides/samples | Organs or cell-line origins | Platforms | Aligned target cells after QC |
|---|---|---|---|---|
| New in-house primary data | 21 | mouse-embryo; cervical; lung | DBiC-seq | 53,989 |
| Public, overlapping HEST-1K | 32 unique slides (33 records) | 22 species--organ strata | Xenium; Visium HD | 11,051,149 |
| Public, overlapping STimage-1K4M only | 2 | 2 species--organ strata | Visium HD | 213,405 |
| Other public data | 44 | 16 species--organ strata | Xenium; Visium HD | 16,996,704 |
| Total sMMC-28M | 99 unique samples (100 records) | 25 tissue strata + 3 cell-line origins | Xenium; Visium HD; DBiC-seq | 28,315,247 |
- New in-house: collaborators provided DBiC-seq native cells paired one-to-one with transcriptomic profiles, available for download and preview.
- Limited overlap: only 32 samples overlap HEST-1K, all from its new Visium HD cohort; about 70% are absent from HEST-1K.
Q2. Clear purpose and biological meaning of the per-axis experiments.
A1 — Scale. We agree and will reorganize the three axes.
- Objective: not a benchmark, but a test of whether more training data improve image-to-expression models.
- Design/metric: Fig. 2 varies training fraction while fixing targets, preprocessing, head, and spatial tests; the metric is held-out gene-macro Pearson. We further tested seven frozen encoders on training-selected top-50 HVGs, four buffered holdouts, and 5%/10%/25%/100% fractions.
| Encoder | 5% | 10% | 25% | 100% |
|---|---|---|---|---|
| ResNet-50 | 0.140 | 0.160 | 0.190 | 0.221 |
| CTransPath | 0.162 | 0.186 | 0.222 | 0.259 |
| Phikon | 0.168 | 0.200 | 0.237 | 0.273 |
| CONCH | 0.178 | 0.213 | 0.256 | 0.292 |
| UNI | 0.188 | 0.218 | 0.259 | 0.295 |
| UNI2 | 0.197 | 0.225 | 0.257 | 0.295 |
| H-Optimus-0 | 0.205 | 0.233 | 0.269 | 0.307 |
- Result: every encoder improves with scale; mean Gene Pearson rises 0.177→0.205→0.241→0.278.
A2 — Resolution (our central benchmark).
- Task: predict aligned-cell RNA expression from histology alone, supporting cell-type/state and other cell-resolved analyses.
- Protocols: in-sample, cross-sample/patient, and cross-platform prediction test increasingly difficult shifts.
- Definitions: STBoost adapts spot-level methods to cells; every reported BLEEP result uses this adaptation. STBoost-Ref further adds diffusion loss and Appendix components. Its strong but imperfect results provide a reference for future methods on this dataset.
Per-organ benchmark results. Results use the top-50 training-selected HVGs, four contiguous spatial holdouts, and a 5% train–test buffer.
| Release category (evaluated species) | Image Gene P | Coordinate Gene P | Spatial KNN Gene P | Gene Spearman | Cell Pearson | F1 |
|---|---|---|---|---|---|---|
| Bone (mouse) | 0.030 | 0.124 | 0.055 | 0.037 | 0.180 | 0.240 |
| Brain (human + mouse) | 0.399 | 0.010 | 0.036 | 0.371 | 0.570 | 0.752 |
| Breast (human) | 0.400 | 0.053 | 0.035 | 0.375 | 0.433 | 0.487 |
| Cervical (human) | 0.178 | 0.017 | 0.014 | 0.157 | 0.247 | 0.026 |
| Colon (mouse) | 0.615 | −0.137 | 0.072 | 0.588 | 0.739 | 0.744 |
| Colorectal (human) | 0.431 | 0.056 | 0.083 | 0.419 | 0.532 | 0.623 |
| Embryo (mouse) | 0.278 | 0.037 | 0.045 | 0.251 | 0.517 | 0.342 |
| Head (zebrafish) | 0.216 | 0.022 | 0.031 | 0.193 | 0.429 | 0.287 |
| Heart (human) | 0.292 | 0.010 | 0.021 | 0.266 | 0.688 | 0.304 |
| Kidney (human) | 0.402 | 0.019 | 0.017 | 0.361 | 0.471 | 0.460 |
| Liver (human) | −0.002 | 0.003 | 0.010 | −0.002 | 0.561 | 0.400 |
| Lung (human) | 0.359 | 0.065 | 0.053 | 0.317 | 0.402 | 0.457 |
| Lymph Node (human) | 0.141 | 0.043 | 0.013 | 0.131 | 0.164 | 0.023 |
| Ovarian (human) | 0.250 | 0.122 | 0.104 | 0.239 | 0.312 | 0.234 |
| Ovarian glands (human) | 0.402 | 0.059 | 0.043 | 0.391 | 0.559 | 0.756 |
| Pancreas (human) | 0.324 | 0.090 | 0.068 | 0.272 | 0.505 | 0.275 |
| Pancreatic (human) | 0.366 | 0.080 | 0.051 | 0.341 | 0.540 | 0.694 |
| Pancreatic duct gland (human) | 0.331 | 0.091 | 0.100 | 0.282 | 0.408 | 0.386 |
| Plant (A. thaliana) | −0.011 | 0.004 | 0.012 | −0.009 | 0.385 | 0.052 |
| Prostate (human) | 0.263 | −0.015 | 0.025 | 0.244 | 0.263 | 0.083 |
| Seed (soybean) | −0.020 | −0.003 | 0.008 | −0.018 | 0.314 | 0.037 |
| Skin (human) | 0.359 | 0.048 | 0.086 | 0.299 | 0.437 | 0.368 |
| Small Intestine (mouse) | 0.572 | −0.104 | 0.067 | 0.548 | 0.701 | 0.715 |
| Tonsil (human) | 0.294 | 0.028 | 0.018 | 0.249 | 0.462 | 0.399 |
| Xenograft (human + mouse) | 0.387 | 0.041 | 0.049 | 0.362 | 0.526 | 0.589 |
| 30-sample macro | 0.324 | 0.046 | 0.053 | 0.291 | 0.442 | 0.413 |
A3 — Rich context.
- Purpose: our rich-context metadata—including age, sex/gender where reported, disease, and underlying clinical conditions—enable us to test whether a model performs consistently across biologically and clinically meaningful subgroups. Average performance alone can hide severe subgroup failures, so such context-aware evaluation is an important dimension for assessing foundation models and other predictive methods.
- Main-text example: the ovarian experiment is one illustrative case. AK (60+)→AD (60+) versus AK (60+)→AL (<40) changes F1 from 0.289 to 0.072, gene Spearman from 0.036 to 0.006, cell Spearman from 0.206 to 0.095, and nonzero rate from 0.166 to 0.027, revealing a large age-associated performance disparity.
- Broader evidence: we conducted analogous audits for other foundation models and contexts. The table below shows substantial assay-, dataset-, and site-associated gaps for Geneformer, scGPT, CONCH, UNI, and H-Optimus-0:
| Domain | Task / encoder | Context; split | Avg. BA | Worst BA | Gap |
|---|---|---|---|---|---|
| Single-cell | Bone marrow / Geneformer | assay; patient-CV | 0.938 | 0.669 | 0.327 |
| Single-cell | Bone marrow / scGPT | assay; patient-CV | 0.962 | 0.740 | 0.258 |
| Single-cell | Bone marrow / scVI-style | assay; patient-CV | 0.932 | 0.616 | 0.373 |
| Single-cell | Ten tissues / scGPT | dataset; patient-CV | 0.667--0.962 | 0.004--0.892 | max 0.975 |
| Pathology | LUAD KRAS / CONCH | site; leave-one-site | 0.499 | 0.375 | 0.542 |
| Pathology | LGG IDH / UNI | site; leave-one-site | 0.682 | 0.464 | 0.471 |
| Pathology | LGG IDH / H-optimus0 | site; leave-one-site | 0.747 | 0.476 | 0.524 |
- Significance and boundary: BA is balanced accuracy, and Gap is best-to-worst performance. The purpose of this axis is to make context-dependent performance bias measurable, not to claim that the resource itself removes bias. Because ovarian age is nested within sample/patient and the panels differ, this example supports an age-associated, sample-confounded shift rather than a causal age effect.
Q3. How are bin2cell targets constructed and validated?
A1 — Construction.
- Appendix S2 shows the official Visium HD registration of native m bins to H&E; intersecting same-frame cell polygons aggregate counts, unsupported cells are removed, and conflicts are resolved deterministically.
- We have moved this pipeline and an example to the main text and now label the outputs derived cell-aligned targets, not measured single-cell RNA.
A2 — Validation. We audited 3,000 raw CellViT polygons per dataset (9,000 total) under 1-m registration shifts. Canonical-bin coverage is reported across all raw polygons; among supported polygons, expression direction remains stable (cosine 0.936--0.994), with Jaccard 0.706--0.816 and median 6.0%--13.7%, indicating reasonable but not perfect robustness:
| Visium HD example | Raw polygons with canonical bins | Shift bin Jaccard | Shift expression cosine | Median absolute change in UMI count |
|---|---|---|---|---|
| Human lung cancer | 49.4% | 0.727--0.733 | 0.954--0.957 | 11.1%--11.3% |
| Mouse brain | 97.5% | 0.806--0.816 | 0.936--0.939 | 6.0%--6.1% |
| Human pancreas | 50.0% | 0.706--0.714 | 0.994 | 13.0%--13.7% |
Q4. How are LMM-generated texts produced and validated?
A1 — Generation. GPT-4o verbalizes supplied fields without adding attributes. We regret omitting the completed audit while shortening this section and will restore prompts, field checks, examples, and matrices:
| Model | Match | Match sim. | Mismatch sim. | Enrichment | Pairwise AUC | Top-1 / Top-3 |
|---|---|---|---|---|---|---|
| PLIP | 15 | 0.262 | 0.053 | 4.96× | 0.993 | 84.6% / 100% |
| CONCH | 29 | 0.040 | 0.0021 | 19.1× | 0.988 | 90.9% / 100% |
A2 — Validation and scope.
- Both VLMs reach AUC and 100% Top-3 retrieval.
- These metrics assess image relevance, while source-field checks assess factuality.
- Text remains optional context, not ground truth.
Clarity
Reviewer 7Gar states:
this paper is substantially lacking in both the rationale for, and the clarity of the experimental design behind, each of its experiments.
and
- Clarity. This is a pervasive problem and it limited my ability to assess the claims. [Many examples given] • There is substantial redundancy — the scale/resolution/rich-context story is repeated many times, while the concrete experimental descriptions that readers actually need are thin.
This remains one of my largest concerns with this paper. Both the original manuscript and the author's rebuttals are confusing to follow, using a dense format that rarely defines key terms.
The authors have partially mitigated this by responding to clarifying questions but given the amount of clarifying editing that is required to the original manuscript, I lack confidence that the authors will be able to resolve this issue in the final manuscript.
Please respond directly to this comment rather than responding in another comment not linked as a reply to this comment (this is another form of clarity that is lacking in the authors other comments).
Data accessibility and format
Reviewer 7Gar comments on this limitation:
(c) data accessibility/reproducibility.
It is unclear from the original manuscript what parts of the dataset will be publicly available, whether the dataset is intended to be made freely available or under paid license, and how upstream data terms may impact the distribution of the dataset, both in licensing and in the format and structure of the data.
it also is unclear what structure the dataset will have. The reviewer metadata includes documentation specifying the the format of a cell_record:
cell_record/
images/
cell_patch # Cell-centered morphology crop
tissue_patch # Local tissue context, about 200 um
wsi_patch # Larger whole-slide context when available
omics/
expression # Xenium panel genes or processed Visium HD targets
gene_names # Target gene order for the expression vector
metadata/
cell_id
sample_id
study_id
platform # Xenium, Visium HD, or harmonized benchmark block
species
organ
tissue
cell_type
disease_state
position_in_tissue
position_in_wsi
context/
neighborhood_features
cell_cell_communication # Ligand-receptor or neighborhood interaction features
language/
caption # Automated morphology and microenvironment description
But the reviewer subset contains only three files for each sample:
attributes.csv
cell.tif
patch.tif
And, for the first example I considered, 1\ghjbkdpc-1, I cannot make out how the cell.tif relates to the patch.tif. The coordinates in attributes.csv do not seem to show how the cell aligns to the larger patch.
Furthermore, it is unclear in what format the gene-expression data will be distributed.
The authors do include 332 MB of DBiC data which they say in another comment is in-house data provided by a collaborator's wet-lab experiments received by them after the initial paper draft.
This data does include .h5ad expression files and .h5 image files. The h5 files contain 100,000 150x150 color images along with center_x and center_y data and the h5ad format is in a well-documented format designed for gene expression data.
But I still remain very uncertain about the format of the proposed dataset, how unified it will be across species and organs, and how clear the format will be to researchers developing new algorithms on it, and, as mentioned briefly above, whether the data will be made both publicly and at no cost (freely) available or how it will be constrained in access or cost by licenses on the existing datasets from which it is derived.
Since, as I mentioned in a recent comment, clarity is one of my remaining large concerns, this is a significant issue for me.
- Rating
- 5/6
- Confidence
- 5/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper describes sMMC-22M, a single cell-level benchmark built from Xenium and Visium HD spatial transcriptomics data with matched histology images and metadata. Its main goal is to move histology-to-gene evaluation from spot-level prediction toward individual cells, while also keeping sample and tissue context available for analysis. The authors use STBoost to run existing prediction pipelines in this setting and report examples including pathology encoder comparisons, cross-patient transfer, and an ovarian age-shift analysis.
Strengths and weaknesses
- The paper addresses a relevant gap in histology-to-gene benchmarking, where many existing resources are still limited to spot-level evaluation.
- The cell-centered data organization is useful, since it links expression, histology crops, spatial coordinates, and metadata around the same biological unit.
- The use of metadata and tissue context is a nice aspect of the benchmark, especially for analyzing failures under patient or age-related shifts rather than only reporting pooled scores.
Questions
- For the Visium HD data, how reliable is the bin-to-cell aggregation used to construct cell-level targets? Could the authors clarify how boundary bins are assigned and whether segmentation errors noticeably affect the resulting expression profiles?
- The main experiments seem to cover only a small number of representative cases. Can the authors provide a compact summary across more organs or platforms, even with a lightweight baseline, to better support the claimed breadth of the benchmark?
- Some reported gene-wise correlations are quite low, especially under transfer settings. How should these scores be interpreted biologically, and could marker-gene, cell-type-associated-gene, or simple spatial-only/metadata-only baselines help calibrate the results?
Limitations
- In-domain results have limited implications, since splits within the same or closely related samples may reflect local interpolation and spatial autocorrelation rather than robust generalization.
- The context analysis is useful but still narrow; the ovarian age-shift experiment is more of a case study than evidence that all biological context variables can be systematically evaluated.
- The resource contains several derived artifacts, such as processed cell-level records, histology crops, captions, and communication summaries, so users need clear guidance on which fields are direct measurements and which are generated or post-processed outputs.
Final justification
The rebuttal addressed most of my major concerns. Resolved: The authors provided additional analyses for the Visium HD cell-aligned targets, expanded the benchmark to all organ categories, added a metadata-based calibration baseline, and clarified the provenance of measured, processed, and generated data. Importantly, the rebuttal goes beyond textual clarification by providing additional analyses and benchmark results that directly address my questions. Remaining: These additions should be incorporated into the revised manuscript rather than remaining only in the rebuttal. Overall, the rebuttal significantly strengthens the paper, and I maintain my positive assessment and support acceptance.
Formatting concerns
None
2 comments
Rebuttal
We thank the reviewer for requesting an HD-construction audit, broader evaluation, and biological calibration. We provide each below while separating native from derived targets and retaining negative transfer results.
Q1. How reliable is Visium HD bin-to-cell aggregation?
A1 — Construction.
- Official transforms register native m bins to H&E; intersecting CellViT polygons aggregate counts, conflicts go to the nearest centroid, and unsupported cells are removed. We will move this rule to the main text and label HD outputs derived cell-aligned, separately from native Xenium.
A2 — Sensitivity audit. We audited 3,000 raw polygons per dataset (9,000 total) under 1-m registration shifts and mask erosion/dilation:
| Visium HD sample | Raw polygons with canonical bins | Shift-bin Jaccard | Shift-expression cosine | Shift median | |---|---:|---:|---:|---:| | Human lung cancer | 49.4% | 0.727--0.733 | 0.954--0.957 | 11.1%--11.3% | | Mouse brain | 97.5% | 0.806--0.816 | 0.936--0.939 | 6.0%--6.1% | | Human pancreas | 50.0% | 0.706--0.714 | 0.994 | 13.0%--13.7% |
Across all raw polygons, coverage is sample dependent. Among supported polygons, shifts largely preserve expression direction but alter membership/UMIs; erosion/dilation gives Jaccard 0.462--0.720, cosine 0.871--0.993, and 32.8%--66.6%. We will release settings/QC and avoid ground-truth language.
Q2. Can the authors summarize more organs/platforms?
A1 — Release-wide breadth. Yes. Table 1 reports results for all 25 release categories.
Table 1. Per-organ benchmark results. Results use the top-50 training-selected HVGs, four contiguous spatial holdouts, and a 5% train–test buffer.
| Release category (evaluated species) | Image Gene P | Coordinate Gene P | Spatial KNN Gene P | Gene Spearman | Cell Pearson | F1 |
|---|---|---|---|---|---|---|
| Bone (mouse) | 0.030 | 0.124 | 0.055 | 0.037 | 0.180 | 0.240 |
| Brain (human + mouse) | 0.399 | 0.010 | 0.036 | 0.371 | 0.570 | 0.752 |
| Breast (human) | 0.400 | 0.053 | 0.035 | 0.375 | 0.433 | 0.487 |
| Cervical (human) | 0.178 | 0.017 | 0.014 | 0.157 | 0.247 | 0.026 |
| Colon (mouse) | 0.615 | -0.137 | 0.072 | 0.588 | 0.739 | 0.744 |
| Colorectal (human) | 0.431 | 0.056 | 0.083 | 0.419 | 0.532 | 0.623 |
| Embryo (mouse) | 0.278 | 0.037 | 0.045 | 0.251 | 0.517 | 0.342 |
| Head (zebrafish) | 0.216 | 0.022 | 0.031 | 0.193 | 0.429 | 0.287 |
| Heart (human) | 0.292 | 0.010 | 0.021 | 0.266 | 0.688 | 0.304 |
| Kidney (human) | 0.402 | 0.019 | 0.017 | 0.361 | 0.471 | 0.460 |
| Liver (human) | -0.002 | 0.003 | 0.010 | -0.002 | 0.561 | 0.400 |
| Lung (human) | 0.359 | 0.065 | 0.053 | 0.317 | 0.402 | 0.457 |
| Lymph Node (human) | 0.141 | 0.043 | 0.013 | 0.131 | 0.164 | 0.023 |
| Ovarian (human) | 0.250 | 0.122 | 0.104 | 0.239 | 0.312 | 0.234 |
| Ovarian glands (human) | 0.402 | 0.059 | 0.043 | 0.391 | 0.559 | 0.756 |
| Pancreas (human) | 0.324 | 0.090 | 0.068 | 0.272 | 0.505 | 0.275 |
| Pancreatic (human) | 0.366 | 0.080 | 0.051 | 0.341 | 0.540 | 0.694 |
| Pancreatic duct gland (human) | 0.331 | 0.091 | 0.100 | 0.282 | 0.408 | 0.386 |
| Plant (A. thaliana) | -0.011 | 0.004 | 0.012 | -0.009 | 0.385 | 0.052 |
| Prostate (human) | 0.263 | -0.015 | 0.025 | 0.244 | 0.263 | 0.083 |
| Seed (soybean) | -0.020 | -0.003 | 0.008 | -0.018 | 0.314 | 0.037 |
| Skin (human) | 0.359 | 0.048 | 0.086 | 0.299 | 0.437 | 0.368 |
| Small Intestine (mouse) | 0.572 | -0.104 | 0.067 | 0.548 | 0.701 | 0.715 |
| Tonsil (human) | 0.294 | 0.028 | 0.018 | 0.249 | 0.462 | 0.399 |
| Xenograft (human + mouse) | 0.387 | 0.041 | 0.049 | 0.362 | 0.526 | 0.589 |
| 30-sample macro | 0.324 | 0.046 | 0.053 | 0.291 | 0.442 | 0.413 |
A2 — Independent-sample evidence.
- Image is strongest in 21/25 rows. Across 18 same-organ held-out targets, top-50-HVG Gene Pearson averages 0.170 (0.016--0.372), Cell Pearson is 0.275 versus 0.205 for the mean, and F1 is 0.125 versus 0.031. These are sample-, not donor-held-out.
A3 — Visium HD transfer. Q3 reports eight complete source→target pairs before and after the requested calibration controls.
Q3. How should low transfer correlations be interpreted and calibrated?
A1 — Reviewer-inspired paired comparison. We thank the reviewer for suggesting metadata/spatial controls. On the identical source→target cells and genes, we compare image-only UNI2-h directly with a segmentation-metadata baseline. Metadata include CellViT type/confidence, polygon/bbox morphology, status, and edge flag; total_counts and n_genes_detected are excluded.
Table 2. Effect of the reviewer-suggested segmentation-metadata calibration on the same eight Visium HD transfer pairs. Gene P is Metadata minus UNI2-h; bold marks the better result for each metric.
| Organ | UNI2-h Gene P | Metadata Gene P | Gene P | UNI2-h Cell P | Metadata Cell P | UNI2-h F1 | Metadata F1 |
|---|---|---|---|---|---|---|---|
| Human breast | 0.0272 | 0.0847 | +0.0575 | 0.1109 | 0.0785 | 0.1794 | 0.1479 |
| Human ovary | 0.0267 | 0.0643 | +0.0376 | 0.4593 | 0.4645 | 0.1161 | 0.0615 |
| Human lung | 0.0143 | 0.0319 | +0.0176 | 0.2121 | 0.1700 | 0.0960 | 0.0267 |
| Human pancreas | 0.0040 | 0.0212 | +0.0172 | 0.0090 | 0.0043 | 0.0389 | 0.0179 |
| Human tonsil | 0.0141 | 0.0282 | +0.0141 | 0.2769 | 0.3696 | 0.0708 | 0.0368 |
| Mouse brain | 0.0243 | 0.0502 | +0.0259 | 0.2016 | 0.2314 | 0.0623 | 0.0223 |
| Mouse embryo | 0.0048 | 0.0176 | +0.0128 | 0.0913 | 0.1662 | 0.0369 | 0.0146 |
| Mouse kidney | 0.0049 | 0.0213 | +0.0164 | 0.2678 | 0.3910 | 0.0513 | 0.0175 |
| Organ macro | 0.0151 | 0.0399 | +0.0248 | 0.2036 | 0.2344 | 0.0815 | 0.0432 |
- The reviewer-suggested baseline improves Gene Pearson in 8/8 organs, from 0.0151 to 0.0399 macro (+0.0248; 2.64×), and improves Cell Pearson in 5/8 organs, from 0.2036 to 0.2344 macro (+0.0308).
- The gain is metric-specific: F1 decreases from 0.0815 to 0.0432. We will therefore adopt segmentation metadata as the principal non-image correlation-calibration baseline, not claim universal superiority. Coordinate-only and metadata+coordinate Gene Pearson are −0.0023/0.0316; age/sex/disease are not identifiable from one source/target pair per organ.
A2 — Biological calibration. Complementary 30-sample spatial holdouts give:
| Metric | Image | Coordinate | Spatial KNN | Mean |
|---|---|---|---|---|
| Marker/HVG Gene Pearson | 0.201 | 0.031 | 0.028 | N/A |
| Cell-type-stratified pseudobulk RMSE | 0.120 | 0.224 | 0.187 | 0.188 |
A3 — Revision. Together, the consistent Gene Pearson improvements and favorable marker/pseudobulk results provide useful calibration for the benchmark. We thank the reviewer for this constructive suggestion and will add the paired comparison and biological-calibration results to the revised manuscript.
Q4. Could in-domain results reflect spatial interpolation?
A. We thank the reviewer for raising this important concern. Random cell splits can be inflated by spatial autocorrelation; ours is spatially separated.
- The original in-domain split trains on the left two-thirds and tests on the right one-third of a section; a 5% buffer removes boundary cells. Train/test cells are therefore neither interleaved nor directly neighboring. The 30-sample benchmark uses four analogous contiguous holdouts.
- Under identical splits, image macro Gene Pearson is 0.324 versus 0.046 for coordinate-only regression and 0.053 for spatial KNN, and image is strongest in 28/30 samples. Local interpolation alone therefore cannot explain the performance.
Q5. Is the ovarian context analysis too narrow?
A1 — Scope of the ovarian result.
- AK (60+)→AD (60+) versus AK→AL (40-) changes F1 0.289→0.072 and gene/cell Spearman 0.036/0.206→0.006/0.095. Because age is nested within sample/patient and panels differ, this is an age-associated, sample-confounded shift, not causal.
A2 — Broader audit. We evaluated foundation models across assay, dataset, and site contexts using patient-CV or leave-one-site-out splits. For each task, we compared average balanced accuracy with the worst supported context and reported their gap. The results show that strong average performance can coexist with substantial context-specific collapse, demonstrating why the resource’s structured metadata are useful for robustness evaluation.
| Task / encoder | Context; split | Average BA | Worst BA | Gap |
|---|---|---|---|---|
| Bone marrow / scGPT | assay; patient-CV | 0.962 | 0.740 | 0.258 |
| Ten tissues / scGPT | dataset; patient-CV | 0.667--0.962 | 0.004--0.892 | max 0.975 |
| LUAD KRAS / CONCH | site; leave-one-site | 0.499 | 0.375 | 0.542 |
| LGG IDH / H-Optimus-0 | site; leave-one-site | 0.747 | 0.476 | 0.524 |
Rich metadata enable worst-context audits; they do not remove bias.
Q6. Which fields are measured, processed, or generated?
A1 — Provenance classes.
| Provenance | Examples |
|---|---|
| Direct | H&E; Xenium transcript coordinates/platform masks; Visium HD m bin counts; source metadata as reported. |
| Processed | Registration; CellViT footprints; Visium HD bin-to-cell matrices; crops; normalized matrices; splits; molecular-profile summaries. |
| Generated | Metadata-grounded GPT-4o captions and model predictions; neither is molecular ground truth. |
A2 — Text scope. GPT-4o verbalizes supplied fields; PLIP/CONCH audits give AUC 0.993/0.988 and 100% Top-3 retrieval. We will restore audit materials; captions remain optional context, not ground truth.
Thank you for the detailed rebuttal. The additional analyses and clarifications address most of my concerns. In particular, the Visium HD robustness analysis, the expanded multi-organ benchmark, the metadata-based calibration baseline, and the clearer distinction between measured, processed, and generated data substantially strengthen the paper. Overall, the rebuttal has successfully addressed my main concerns, and I am inclined to support acceptance, provided these revisions are incorporated into the final manuscript.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper publish sMMC-22M, a single-cell spatial transcriptomics dataset with over 20 million cells across 25 organ categories, which enjoys larger scale, higher resolution and richer context compared to existing dataset in literature.
Strengths and weaknesses
Strength: the new dataset enjoys larger scale, higher resolution and richer context, which potentially can support more study refined research on the spatial transcriptomics and reveal more biological insights.
Weakness: The extent to which this new data can truly promote relevant research progress has not been fully explained.
Questions
the increase of the data scale, resolution and contexts typically associates with the increase of data heterogeneity, which may pose critical challenges for data analysis. please clarify the heterogeneity of the new dataset and how it may influence the downstream data analysis.
Limitations
yes
Formatting concerns
No
1 comment
Rebuttal
We sincerely thank the reviewer for identifying two questions that the manuscript had not explained clearly enough: how the data promote research, and how increased heterogeneity affects downstream analysis. We will organize the revision around these questions, revise point by point, and hope the reviewer will reconsider.
Q1 (Weakness). How can the new data truly promote relevant research progress?
A1 — Lowering practical barriers. Existing data are fragmented across platforms, panels, formats, segmentation, and metadata schemas. sMMC provides one cell-aligned interface for morphology, context, molecular targets, coordinates, and available donor metadata. The 25-organ release becomes usable through one pipeline while preserving provenance: native Xenium/DBiC-seq cells remain distinct from Visium HD targets derived within cell masks. Data loading, preprocessing, splitting, and evaluation can therefore be reused across studies.
A2 — Enabling reproducible method development. Image-only local-cell and tissue-context crops predict RNA aligned to a cell. STBoost lets existing spot predictors use this hierarchical interface while retaining their prediction modules.
The resource supports several complementary research settings:
- spatially separated regions for within-sample prediction;
- complete-sample transfer for acquisition/composition shifts;
- verified patient/donor holdout for biological transfer;
- panel-matched cross-platform transfer;
- 25-organ breadth and context-aware evaluation.
Together, these protocols ask whether additional data help, whether encoders capture morphology rather than location, and whether gains persist across organs, donors, technologies, and contexts. A fixed interface also lets new architectures, normalization methods, and adaptation strategies be compared without rebuilding the dataset.
Fixed splits and code let future methods use identical targets, supporting studies of scaling, foundation encoders, adaptation, robust learning, and biological transfer. This is infrastructure for comparing progress, not a claim that prediction is solved.
A3 — Expanding cell-centered downstream research. Spots merge cells with different identities, states, and responses. Moving image and molecular targets toward the same cell preserves local heterogeneity and supports:
- cell type/state: connect morphology with identity and disease programs;
- cell–cell communication: study neighboring-cell interactions and tissue architecture;
- virtual-cell/perturbation modeling: link morphology, context, state, and response, then trace effects through interacting cells;
- microenvironment analysis: distinguish cells within a niche rather than assign one averaged profile.
sMMC does not solve these tasks; it supplies a common substrate for training and evaluating them across organs and contexts. We will state these opportunities explicitly.
Q2 (Heterogeneity). What heterogeneity is introduced by increased scale, resolution, and context, and how may it influence downstream analysis?
A1 — Sources of heterogeneity. We agree that a larger resource contains more variation. We will document:
- biological: organ, species, disease, composition, density, and donor;
- technical: platform, study, acquisition, segmentation, and resolution;
- molecular: panel overlap, coverage, sparsity, and target construction;
- context: uneven support for age, sex, disease, site, and patient;
- scale: unequal samples/cells across organs and studies.
A2 — Downstream influence. Cell-weighted pooling can let large organs dominate; unmatched panels make gene metrics incomparable; platform/study effects can resemble biology; segmentation and density change targets and neighborhood mixing; incomplete donors make sample shift look like patient shift; uneven context support confounds subgroup comparisons. A model may therefore optimize dominant tissues, learn technical signatures, or appear robust because averaging hides rare-context failures. Heterogeneity defines deployment shifts, while the unified manifest supports normalization, panel alignment, adaptation, calibration, and robust generalization.
A3 — Controls and manuscript revisions. Following the reviewer’s advice, we will:
- report organ-macro/platform-separated summaries and panel overlap;
- separate native/derived targets and spatial/sample/patient/platform protocols;
- report Average/Worst/Gap, donor support, and missingness;
- reserve “patient-held-out” for independent donors;
- label measured, processed, generated, and model-derived fields.
These changes do not remove heterogeneity; they make its downstream effects auditable. We again thank the reviewer: these two questions make the resource’s purpose, opportunities, and limitations clearer.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Rebuttal
We thank the reviewer for emphasizing target provenance, breadth, and cell alignment. We separate native/derived targets, report all 25 categories, and retain difficult transfer results. We hope the reviewer will reconsider after our point-by-point response. Under the character limit, we give central evidence here and fuller responses during open comments.
Q1 (P2, Q2, Q4, L1–L2). Are the molecular targets truly single-cell?
A1 — Molecular-target provenance. The resource has three evidence types:
A2 — Derived HD construction and audit.
Expression direction is stable among supported polygons, while bin membership/UMIs remain boundary-sensitive. We will move this construction and QC into the main body.
Q2 (P3, Q1). Are all 25 release categories evaluated?
A1 — 25-category results. Yes; Table 1 reports all 25 categories under one protocol.
Table 1. Per-organ benchmark results. Results use the top-50 training-selected HVGs, four contiguous spatial holdouts, and a 5% train–test buffer.
A2 — Cross-sample transfer. We evaluated eight source→target organ pairs.
Table 2. Eight-organ cross-sample benchmark (source→target sample). TM is training mean; its Gene Pearson is undefined.
Q3 (P6, P7). What are the benchmark inputs, experimental design, and STBoost definitions?
A.
Q4 (Q3, L3). What does cell alignment add beyond spot-centered prediction?
A. We thank the reviewer for this suggestion.
Q5 (P4, P8, P9, L4). What do the context analysis and available metadata support?
A1 — Representativeness. We agree representation cannot be assumed. Ethnicity is undocumented and context coverage varies. We will report missingness, infer no absent sensitive attributes, and avoid unsupported population-level fairness claims.
A2 — Context-bias evaluation. Average scores can hide failures by assay, dataset, site, age, or disease. Patient-CV/leave-one-site-out audits report Average/Worst/Gap:
Context materially changes performance; structured metadata make this measurable.
A3 — Reporting scope.
Q6 (P5, second Q4, minor remarks). How will naming, Figure 1, and presentation be revised?
A1 — Figure 1. Figure 1 was not AI-generated. I began this resource in my first PhD year; over three years, the figure had two manually drawn Sketch versions and now has 161 editable vector layers. Layer-workspace screenshots are in our anonymous repository under
figure_evidence_not_AI/.A2 — Revisions.