potentialpaper

Look Before You Leap: Self-Evolving Clinical Reasoning with Psychometric Preference Optimization for Radiology Report Generation

Qi Wang, Yunfeng Min, Liwei Huang, Zeyu Zhang, Di Gai, Jun Liu

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. We propose Look-Before-You-Leap, a self-evolving clinical reasoning and psychometric preference optimization framework for trustworthy radiology report generation.

Abstract. Despite the remarkable progress of large Vision-Language Models (VLMs) in Radiology Report Generation (RRG), existing black-box autoregressive generation paradigms lack intermediate clinical logical reasoning. This deficiency renders such models prone to generating linguistically fluent reports with erroneous diagnostic findings, which manifest as plausible hallucinations and thereby undermine clinical reliability. To this end, we propose a novel RRG paradigm termed "Look-Before-You-Leap", aimed at enhancing the clinical logical reasoning capabilities of the model to improve diagnostic accuracy. Specifically, we first construct a self-evolving Radiological Skill (RadSkill) repository to guide the teacher model in distilling high-confidence explicit clinical reasoning, and further internalize this reasoning capability into the implicit diagnostic intuition of the RRG baseline. Building upon this foundation, a novel preference optimization method termed Psychometric Preference Optimization (PSY-PO) is proposed. Grounded in Item Response Theory (IRT) from psychometrics, this method precisely samples clinically misleading dispreferred reports for preference optimization, thereby effectively mitigating plausible hallucinations. Extensive experimental results demonstrate that our proposed method significantly enhances both the generation quality and trustworthiness of radiology reports.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
2 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:44 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The paper proposes a three-stage radiology report generation framework. A self-evolving RadSkill repository is refined by a failure-driven loop; a teacher model uses the repository to generate clinical reasoning trajectories that a report generator internalizes through SFT so no explicit reasoning chain is needed at inference; and Psychometric Preference Optimization (PSY-PO) treats historical checkpoints as examinees under Item Response Theory to select clinically misleading hard negatives for preference training. Experiments on MIMIC-CXR and IU X-Ray report improvements over a report-only baseline and several prior RRG systems.

The concerns from reviewers are as follows:

  1. Hallucination evidence. A trustworthiness/hallucination-reduction paper needs human evaluation beyond NLG and CE metrics (Reviewer oecC); Reviewer jtfF sharpens this by asking for entity/relation, anatomy-location, or negation/uncertainty error analysis.

  2. Trajectory faithfulness. CheXbert/RadGraph signals appear both in method construction and evaluation, weakening independence, and the SECR trajectories need auditing on cases where the teacher adds, misses, or contradicts findings (Reviewer jtfF and Reviewer w3ai).

  3. Baseline comparability and uncertainty. It is unclear which Table 3 baselines were rerun under identical preprocessing versus cited (Reviewer jtfF); Reviewer oecC notes Tables 1-3 have no error bars, and Reviewer w3ai independently asks why Rep-SFT in Table 2 looks stronger than several SOTA methods in Table 3.

  4. Related-work coverage and reproducibility. Reasoning-focused RRG methods (RadAgents, CheXOne, ORGAN, CoMT) are missing (Reviewer oecC); Reviewer jtfF asks for PSY-PO construction details (candidate pool size, perturbation prompts, decoding, 3PL fitting) and flags a stray checklist template block.

Final justification

During the rebuttal phase, the reviewers acknowledged that their concerns had been adequately addressed and provided positive evaluations.

Area Chair 6wqj · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The paper proposes a three-stage radiology report generation framework. A self-evolving RadSkill repository is refined by a failure-driven loop; a teacher model uses the repository to generate clinical reasoning trajectories that a report generator internalizes through SFT so no explicit reasoning chain is needed at inference; and Psychometric Preference Optimization (PSY-PO) treats historical checkpoints as examinees under Item Response Theory to select clinically misleading hard negatives for preference training. Experiments on MIMIC-CXR and IU X-Ray report improvements over a report-only baseline and several prior RRG systems.

The concerns from reviewers are as follows:

  1. Hallucination evidence. A trustworthiness/hallucination-reduction paper needs human evaluation beyond NLG and CE metrics (Reviewer oecC); Reviewer jtfF sharpens this by asking for entity/relation, anatomy-location, or negation/uncertainty error analysis.

  2. Trajectory faithfulness. CheXbert/RadGraph signals appear both in method construction and evaluation, weakening independence, and the SECR trajectories need auditing on cases where the teacher adds, misses, or contradicts findings (Reviewer jtfF and Reviewer w3ai).

  3. Baseline comparability and uncertainty. It is unclear which Table 3 baselines were rerun under identical preprocessing versus cited (Reviewer jtfF); Reviewer oecC notes Tables 1-3 have no error bars, and Reviewer w3ai independently asks why Rep-SFT in Table 2 looks stronger than several SOTA methods in Table 3.

  4. Related-work coverage and reproducibility. Reasoning-focused RRG methods (RadAgents, CheXOne, ORGAN, CoMT) are missing (Reviewer oecC); Reviewer jtfF asks for PSY-PO construction details (candidate pool size, perturbation prompts, decoding, 3PL fitting) and flags a stray checklist template block.

Final justification

During the rebuttal phase, the reviewers acknowledged that their concerns had been adequately addressed and provided positive evaluations.

1 comment
Authors · CommentOpenReview ↗

Response to the Area Chair’s Meta-Review

Thank you for the constructive feedback. We have addressed the four concerns with additional experiments and corresponding analyses, and clarifications, as summarized below:

1.Hallucination evidence. In our rebuttal response to Reviewer oecC’s Question 1 & Limitation 1, we have added a radiologist-based evaluation involving five radiologists on 50 cases sampled from each of the MIMIC-CXR and IU X-Ray test sets, together with the corresponding results table and analysis. In our rebuttal response to Reviewer jtfF’s Question 1, we have also presented this radiologist-based evaluation, together with an analysis of uncertainty errors and the corresponding tabulated experimental results.

2.Trajectory faithfulness. In our rebuttal response to Reviewer jtfF’s Question 1, we have added an evaluation independent of CheXbert/RadGraph, in which GPT-5.5 and five radiologists audited reasoning trajectories from 50 cases sampled from each of the MIMIC-CXR and IU X-Ray test sets, together with the corresponding results table and analysis. In our rebuttal response to Reviewer w3ai’s Question 2, we have clarified how the Dynamic Evolution Loop identifies and corrects teacher-generated trajectories that add, omit, or contradict findings.

3.Baseline comparability and uncertainty. In our rebuttal response to Reviewer jtfF’s Question 3, we have clarified that Table 3 reports results cited from the original papers and added a controlled comparison by reproducing several SOTA methods under a unified setting. In response to Reviewer oecC’s Question 3, we have repeated the experiments in Tables 1–3 using three random seeds and reported the corresponding results in three tables. In response to Reviewer w3ai’s Question 1, we have added an analysis explaining why Rep-SFT outperforms several SOTA methods.

4.Related-work coverage and reproducibility. In our rebuttal response to Reviewer oecC’s Question 2 & Limitation 3, we have expanded the discussion of reasoning-focused RRG methods, together with the corresponding comparison table and analysis. In our rebuttal response to Reviewer jtfF’s Question 5, we have also provided detailed PSY-PO construction settings.

Reviewer jtfFOpenReview ↗
Rating
5/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper proposes “Look-Before-You-Leap”, a framework for radiology report generation that combines explicit clinical reasoning supervision with preference optimization. The method builds a self-evolving RadSkill repository to generate clinical reasoning trajectories, trains the RRG model to internalize this reasoning into direct report generation, and then applies Psychometric Preference Optimization (PSY-PO), where historical checkpoints are treated as IRT “examinees” to select hard hallucinated negatives for preference training. Experiments on MIMIC-CXR and IU X-Ray report improvements over a report-generation baseline and several prior RRG systems.

Strengths and weaknesses

The paper has a genuinely interesting central idea. Using intermediate clinical reasoning to improve final report generation is a natural direction for RRG, and the authors make a reasonable case that simply doing black-box autoregressive generation is not enough for clinically reliable reports. I also like the attempt to avoid generating long reasoning chains at inference time: the GRG stage tries to get the benefit of explicit reasoning supervision while keeping the final model as a direct report generator.

The PSY-PO component is also more interesting than a standard “generate bad answers and run DPO” recipe. Treating historical checkpoints as models with different diagnostic ability and using an IRT-inspired criterion to select hard negatives is a neat framing. The additional ablations in the appendix help: rejected-response sampling, number of checkpoints, IRT parameterization, and skill-evolution epochs all support the main design choices to some extent. The paper is stronger because those ablations are there.

My main concern is that the paper’s strongest claims, especially about clinical reasoning, trustworthiness, and hallucination reduction, are mostly evaluated through automatic proxies. The method itself uses CheXbert/RadGraph-style signals in several places: label-balanced sampling, RadSkill construction, checkpoint ability estimation, and entity-overlap-based response modeling. The main clinical evaluation also relies on CheXbert CE metrics. This is not direct test leakage, but it makes the evidence somewhat self-referential. I would be much more convinced by evaluation that checks anatomy-location errors, uncertainty/negation errors, relation-level hallucinations, or a small expert review of generated reports and reasoning traces.

The “self-evolving clinical reasoning” story is also not fully validated. The reasoning trajectories are generated by a teacher model using ground-truth reports and a hand/lexicon-guided skill repository, then revised through failure cases. But the paper does not directly show that these trajectories are clinically correct, faithful to the image, or better aligned with radiologist reasoning. The qualitative examples help, but they are not enough for the strength of the claim.

The SOTA comparison in Table 3 is hard to interpret. The compared systems use different encoders, decoders, model sizes, training pipelines, and possibly preprocessing/evaluation scripts. Since the paper claims leading performance and emphasizes the small 0.5B decoder, it should be clearer which baselines were rerun under the same setting and which numbers are copied from prior work. Without a controlled comparison, the leaderboard-style conclusion feels overconfident.

Finally, reproducibility and uncertainty are weaker than I would like. The paper gives many details and prompts, but some critical implementation choices remain unclear: the exact hallucination candidate generation process, candidate pool size, decoding settings, optimizer/LR details, how IRT fitting is stabilized, and the exact randomness/seed behavior. The checklist also says no error bars or significance tests are reported, which matters because some improvements in the appendix are modest.

Questions
  1. Can you provide additional evaluation focused on clinically meaningful hallucinations, such as anatomy-location errors, uncertainty/negation errors, relation-level finding-location errors, or a small expert review? This would directly test whether the method reduces clinically meaningful hallucinations, not just CheXbert label mismatches.

  2. How do you validate the quality and image-faithfulness of the SECR reasoning trajectories themselves? If a teacher-generated reasoning chain is wrong but still fluent, GRG may internalize that error. A small manual audit or automatic faithfulness analysis would help a lot.

  3. For Table 3, which baselines were rerun using the same preprocessing, Findings-only setting, decoding, and evaluation scripts? If many are copied from prior papers, please soften the SOTA/small-model claims or add a controlled comparison against the strongest baseline you can rerun.

  4. Can you report variability over random seeds or at least bootstrap confidence intervals for the main MIMIC-CXR and IU X-Ray results? The checklist says no error bars are included, and some ablation gains are small enough that uncertainty matters.

  5. Can you clarify key PSY-PO construction details, especially hallucination candidate pool size, perturbation prompts, decoding settings, and 3PL fitting/stabilization? This would make the preference construction much easier to reproduce.

Limitations

No. The authors mention two useful limitations: the work is limited to chest X-ray Findings generation, and SECR depends on the teacher model. But the limitations should also discuss dependence on automatic clinical labelers/graph extractors, lack of independent clinical review, possible errors in teacher-generated reasoning trajectories, and the cost/fragility of building preference data from many checkpoints. The SOTA and efficiency claims are also limited by potentially heterogeneous baseline evaluation settings.

Final justification

The rebuttal and follow-up discussion materially changed my assessment. The authors added a blinded and randomized evaluation of generated reports on 100 cases by five radiologists who had access to the corresponding chest X-rays. They also clarified the rating aggregation procedure and reported moderate inter-reader agreement. This directly addresses my main concern that the hallucination and trustworthiness claims were supported only by automatic proxies.

The authors further added an audit of the reasoning trajectories, controlled baseline comparisons, three-seed results, and missing PSY-PO implementation details. They appropriately clarified that the trajectory evaluation measures agreement with the reference report rather than direct image faithfulness and will rename the metric accordingly. They also committed to softening the SOTA claims and expanding the limitations.

Given these additions and clarifications, I consider the main concerns resolved and update my rating from Borderline Reject to Accept.

Formatting concerns

No major anonymity concern. Minor formatting/checklist issue: the paper appears to still include the checklist template instruction block telling authors to delete it.

5 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Question 1: Thank you for the constructive suggestion. To directly evaluate clinically meaningful hallucinations, rather than relying solely on CheXbert label mismatches, we have randomly sampled 50 cases from each of the MIMIC-CXR and IU X-Ray test sets. These labels were used solely for case selection and were not involved in model training or hyperparameter tuning. We have further conducted an expert evaluation involving five radiologists, who independently assessed the hallucination severity and clinical usefulness of the generated reports. Hallucination severity is scored as follows: Correct Statement = 0, Mild Hallucination = 0.4, Moderate Hallucination = 0.7, and Severe Hallucination = 1. Clinical usefulness is scored as follows: Clinically Acceptable = 1, Nearly Acceptable = 0.75, Moderately Acceptable = 0.5, Unacceptable = 0.25, and Unusable = 0. We have also employed the GREEN metric [a] to evaluate factual correctness on the same cases. The table below reports the results of each ablation variant and several representative state-of-the-art methods on these three metrics, where lower hallucination severity is better, whereas higher clinical usefulness and GREEN scores are better.

Different Modules and Methods MIMIC-CXR GREEN ↑ MIMIC-CXR Hallucination Severity ↓ MIMIC-CXR Clinical Usefulness ↑ IU X-Ray GREEN ↑ IU X-Ray Hallucination Severity ↓ IU X-Ray Clinical Usefulness ↑
Baseline 0.283 0.579 0.535 0.612 0.501 0.695
+SECR w/o Evo 0.313 0.546 0.590 0.630 0.427 0.650
+SECR 0.340 0.438 0.645 0.654 0.295 0.705
+PSY-PO 0.351 0.367 0.695 0.691 0.224 0.755
COMG + RL [6] 0.298 0.331 0.620 0.664 0.188 0.710
R2Gen-Mamba [34] 0.334 0.359 0.675 0.685 0.260 0.685
Ours 0.371 0.295 0.755 0.712 0.120 0.825

[a] Ostmeier S, Xu J, Chen Z, et al. Green: Generative radiology report evaluation and error notation[C]//Findings of the Association for Computational Linguistics: EMNLP 2024. 2024: 374–390.


Question 2: Thank you for the constructive suggestion. We conducted a small-scale audit of the clinical reasoning trajectories under fixed model configurations and experimental settings. For automatic evaluation, 500 cases were randomly sampled from the pooled MIMIC-CXR and IU X-Ray datasets and assessed by GPT-5.5 as the LLM judge. For manual evaluation, an independent sample of 100 cases from the same pooled data was reviewed by five radiologists. Specifically, using the reference radiology reports as the evaluation basis, GPT-5.5 assigned separate scores from 0 to 10 for image-faithfulness and reasoning quality. Image-faithfulness measures the consistency between the statements in a reasoning trajectory and the imaging findings described in the reference report, whereas reasoning quality assesses the soundness of the reasoning process and whether its conclusions are adequately supported by relevant evidence. For the manual audit, image-faithfulness was graded as Fully Faithful = 1.0, Mostly Faithful = 0.6, Partially Faithful = 0.3, and Unfaithful = 0. Reasoning quality was graded as Sound Reasoning = 1.0, Mostly Sound Reasoning = 0.75, Partially Sound Reasoning = 0.5, Flawed Reasoning = 0.25, and Invalid Reasoning = 0. The table below reports the automatic and human evaluation results for the Initial Reasoning and the SECR-evolved Reasoning, where higher scores indicate better image-faithfulness and reasoning quality. The results show that SECR achieves clear improvements on both dimensions.

Reasoning Stage Automatic Analysis Automatic Analysis Manual Audit Manual Audit
Reasoning Quality ↑ Image-Faithfulness ↑ Reasoning Quality ↑ Image-Faithfulness ↑
Reasoning Chain w/o Evo 7.552 6.676 0.625 0.526
Reasoning Chain 8.829 8.270 0.823 0.740

Question 3: In table 3, we reported the results from the original papers of the compared methods. To enable a more controlled and fair comparison, we have further reproduced and evaluated several SOTA methods on IU X-Ray, as shown in the table below. All methods were evaluated using the same data preprocessing, Findings-only setting, decoding strategy, and evaluation scripts as our method. Under this unified experimental setting, our method achieves the best performance. Following your suggestion, we will also soften the claims regarding SOTA performance and the superiority of small models in the final version.

Methods BLEU-4 METEOR ROUGE-L
CoMT 0.140 0.171 0.324
COMG 0.205 0.218 0.384
R2Gen-Mamba 0.168 0.201 0.376
CheXOne 0.171 0.203 0.382
Ours 0.241 0.230 0.395

Question 4: We have further repeated the ablation studies, SOTA comparisons, and selected experiments in the Appendix (Tables C.4 and C.5) using three different random seeds. The results are reported in the four tables below. The standard deviations of all evaluation metrics are no greater than 0.01, indicating consistently low variation across runs. Together with the mean performance, these results further validate the effectiveness and stability of the proposed method.

Different Modules IU X-Ray BLEU-4 IU X-Ray METEOR IU X-Ray ROUGE-L IU X-Ray Precision IU X-Ray Recall IU X-Ray F1
Baseline 0.173 ± 0.010 0.203 ± 0.002 0.348 ± 0.007 0.490 ± 0.005 0.426 ± 0.003 0.456 ± 0.003
SECR w/o Evo 0.194 ± 0.003 0.210 ± 0.003 0.361 ± 0.003 0.530 ± 0.007 0.475 ± 0.009 0.500 ± 0.006
SECR 0.209 ± 0.010 0.228 ± 0.001 0.379 ± 0.009 0.550 ± 0.006 0.491 ± 0.005 0.519 ± 0.006
PSY-PO 0.212 ± 0.003 0.220 ± 0.002 0.376 ± 0.003 0.556 ± 0.007 0.518 ± 0.009 0.536 ± 0.006
Ours 0.240 ± 0.002 0.231 ± 0.002 0.395 ± 0.003 0.602 ± 0.006 0.552 ± 0.008 0.576 ± 0.005
Method MIMIC-CXR BLEU-4 MIMIC-CXR METEOR MIMIC-CXR ROUGE-L MIMIC-CXR Precision MIMIC-CXR Recall MIMIC-CXR F1 IU X-Ray BLEU-4 IU X-Ray METEOR IU X-Ray ROUGE-L
Ours 0.165 ± 0.003 0.181 ± 0.002 0.310 ± 0.004 0.636 ± 0.008 0.476 ± 0.010 0.546 ± 0.007 0.240 ± 0.002 0.231 ± 0.002 0.395 ± 0.003
IRT Parameterization BLEU-4 METEOR ROUGE-L Precision Recall F1
1PL 0.204 ± 0.003 0.214 ± 0.003 0.369 ± 0.004 0.542 ± 0.007 0.500 ± 0.005 0.520 ± 0.006
2PL 0.208 ± 0.003 0.217 ± 0.002 0.373 ± 0.004 0.548 ± 0.006 0.510 ± 0.006 0.528 ± 0.006
3PL 0.213 ± 0.002 0.220 ± 0.003 0.376 ± 0.003 0.557 ± 0.006 0.517 ± 0.007 0.536 ± 0.005
Model BLEU-4 METEOR ROUGE-L Precision Recall F1
Baseline 0.074 ± 0.003 0.146 ± 0.002 0.247 ± 0.003 0.513 ± 0.006 0.528 ± 0.007 0.520 ± 0.006
Baseline w/ SECR 0.086 ± 0.002 0.149 ± 0.001 0.268 ± 0.002 0.532 ± 0.005 0.527 ± 0.006 0.529 ± 0.006

Question 5: The hallucination candidate pool size=10 for each reference report, with candidates generated by Qwen3.5-9B through independent sampling. The decoding settings are temperature=0.7, max tokens=512, and presence penalty=1.0. To ensure stable 3PL fitting, we estimate a, b, and c by maximizing the Bernoulli log-likelihood using L-BFGS-B [b], which performs line search rather than relying on a fixed learning rate. We initialize a=1, b=median(ηq), and c=0.05, while restricting a, b, and c to [0.01,5], [−4,4], [0,0.35], respectively. We will add these PSY-PO construction details to the Appendix of the final version to facilitate reproducibility.

[b] Zhu, C., Byrd, R. H., Lu, P., & Nocedal, J. (1997). Algorithm 778: L-BFGS-B: Fortran subroutines for large-scale bound-constrained optimization. ACM Transactions on Mathematical Software, 23(4), 550–560.

Limitation 1: We agree that the above limitations were not sufficiently discussed in the original manuscript. First, regarding the dependence on graph extractors, subtle errors introduced by RadGraph during medical entity and relation extraction may propagate into the construction of the skill supervision set. Future work could employ multiple graph extractors, such as RadGraph and RadGraph-XL, for consistency checking. Only results consistently identified by multiple extractors would be treated as high-confidence supervision, while conflicting results could be down-weighted, discarded, or subjected to expert review, thereby improving the reliability of the skill supervision set. Second, regarding the lack of independent clinical review and possible errors in teacher-generated reasoning trajectories, we have added corresponding experiments and discussions in our responses to Questions 1 and 2. For the SOTA and efficiency claims, which may be affected by heterogeneous evaluation settings, we have provided more controlled comparisons in our response to Question 3 and will soften the corresponding claims. Regarding the cost of constructing preference data, we acknowledge that sampling and selecting hard negatives from multiple checkpoints introduces additional time overhead. Compared with standard DPO, our method achieves further reductions in plausible hallucinations at an acceptable additional computational cost. Moreover, whereas conventional IRT typically requires multiple independent models as examinees, we reuse historical checkpoints produced during training, thereby reducing the cost of invoking additional LLMs to some extent. We will expand the discussion of all these limitations in the final version.

Reviewer jtfF · CommentOpenReview ↗

Thank you for the detailed response. I have read it carefully. The new radiologist evaluation, trajectory audit, controlled IU X-Ray comparisons, three-seed results, and additional PSY-PO details address most of my concerns and make me more positive about the paper.

I have one important clarification about the expert evaluation. Did the radiologists have access to the chest X-rays when assessing both the generated reports and the reasoning trajectories? Were the outputs presented blinded to the method and in randomized order? Please also clarify how the five ratings were aggregated and report inter-reader agreement or uncertainty if available. The response says that image-faithfulness was assessed using the reference report as the evaluation basis; if the images were not shown, this should be described as consistency with the reference report rather than image-faithfulness.

For the final version, please include the complete expert-evaluation protocol and new results, the exact negative-generation prompt, the three-seed results, the controlled baseline setup, and the expanded limitations. Please also soften the SOTA/small-model claims and remove the remaining checklist instruction block as promised. I am not asking for another large experiment; clarification of the existing evaluation protocol and uncertainty from the collected ratings would be sufficient.

Subject to this clarification, my main concerns are largely resolved.

Authors · CommentOpenReview ↗

Response to Reviewer jtfF’s Follow-up Questions

Thank you for the careful follow-up and positive assessment. We clarify the expert-evaluation protocol below:

1.Access to chest X-rays: The radiologists were provided with the corresponding chest X-rays when evaluating the generated reports. However, the chest X-rays were not shown when evaluating the reasoning trajectories; only the reasoning trajectories and reference reports were provided. We will clarify these two evaluation settings in the final manuscript.

2.Blinding and randomization: Yes. For the 50 randomly selected cases from each dataset, both the compared methods and their corresponding outputs were anonymized, and the outputs were presented to each radiologist in randomized order. The radiologists remained blinded to the generating method throughout the evaluation.

3.Rating Aggregation: Thank you for your suggestion. We further clarify the rating aggregation procedure. 5 radiologists independently evaluated the same set of sampled instances. The expert-evaluation comprises four dimensions: Hallucination Severity and Clinical Usefulness for generated reports, and Reasoning Quality and Report-Faithfulness for reasoning trajectories. Since the corresponding chest X-rays were not provided to the radiologists during the reasoning trajectory evaluation, we rename the original Image-Faithfulness metric as Report-Faithfulness. For an evaluated method or ablation variant m, evaluation dimension q, and sampled instance i, we first average the ratings from the 5 radiologists:

sˉi,m(c)=15∑r=15si,m,r(c)\bar{s}_{i,m}^{(c)}=\frac{1}{5}\sum_{r=1}^{5}s_{i,m,r}^{(c)}

Here, si,r(m,q)s_{i,r}^{(m,q)} denotes the score assigned by radiologist rr to the ii-th sampled instance, either a generated report or a reasoning trajectory, under method or ablation variant mm and evaluation dimension qq.

We then sum the instance-level mean scores over the NN sampled instances and divide by NN to obtain the final evaluation score:

sˉ(m,q)=1N∑i=1Nsˉi(m,q)\bar{s}^{(m,q)}=\frac{1}{N}\sum_{i=1}^{N}\bar{s}_{i}^{(m,q)}

For the generated-report evaluation, we randomly sampled 50 cases from each of the IU X-Ray and MIMIC-CXR test sets; therefore, N=50 for each dataset. For the reasoning trajectory evaluation, we randomly sampled 100 generated reasoning trajectories; therefore, N=100.

4. Inter-Reader Agreement: To assess agreement among the five radiologists, we compute ordinal Krippendorff’s alpha α(m,q)\alpha^{(m,q)} [c] separately for each compared method or ablation variant mm and each evaluation dimension qq. A value closer to 1 indicates stronger agreement among the radiologists, whereas α(m,q)=0\alpha^{(m,q)}=0 indicates agreement equivalent to that expected under random ratings. The resulting inter-reader agreement scores are reported in the two tables below:

Datasets Methods Hallucination Severity Agreement Clinical Usefulness Agreement
IU-X-Ray Baseline 0.672 0.731
IU-X-Ray +SECR w/o Evo 0.723 0.660
IU-X-Ray +SECR 0.681 0.670
IU-X-Ray +PSY-PO 0.708 0.718
IU-X-Ray COMG+RL 0.659 0.670
IU-X-Ray R2Gen-Mamba 0.733 0.698
IU-X-Ray Ours 0.698 0.729
MIMIC-CXR Baseline 0.716 0.741
MIMIC-CXR +SECR w/o Evo 0.664 0.670
MIMIC-CXR +SECR 0.742 0.701
MIMIC-CXR +PSY-PO 0.703 0.681
MIMIC-CXR COMG+RL 0.676 0.730
MIMIC-CXR R2Gen-Mamba 0.729 0.671
MIMIC-CXR Ours 0.655 0.662
Reasoning Stage Reasoning Quality Agreement Image Faithfulness Agreement
Reasoning Chain w/o Evo 0.712 0.748
Reasoning Chain 0.739 0.733

Overall, the Krippendorff’s alpha values for Hallucination Severity, Clinical Usefulness, Reasoning Quality, and Report-Faithfulness ranged from 0.655–0.742, 0.660–0.741, 0.712–0.739, and 0.733–0.748, respectively. These results indicate moderate inter-reader agreement among the five radiologists across the four evaluation dimensions.

[c] Krippendorff, K. Content Analysis: An Introduction to Its Methodology. 4th ed. SAGE Publications, 2018.

5.Evaluation Terminology and Definition: We agree that the term “image-faithfulness” is imprecise because the corresponding chest X-rays were not provided when evaluating the SECR reasoning trajectories. The evaluation was based solely on the clinical findings and related descriptions documented in the reference reports. To avoid ambiguity, we will replace “image-faithfulness” with “report-faithfulness,” which measures the consistency between the statements in a reasoning trajectory and the content of the corresponding reference report. We will also clarify its definition and evaluation protocol in the final version.

In the final version, we will include the complete expert-evaluation protocol, rating aggregation procedure, uncertainty and inter-reader agreement results, the exact negative-generation prompt, the three-seed results, the controlled baseline setup, and the expanded limitations. We will also soften the SOTA/small-model claims and remove the remaining checklist instruction block as promised.

Reviewer w3aiOpenReview ↗
Rating
5/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
4/4
Originality
4/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper introduces a new radiology report generation (RRG) framework designed to improve clinical reliability and reduce hallucinations in generated reports. The core idea is to build a self-evolving radiology skill repository that guides a teacher model through a dynamic evolution loop, enabling the generation of high-quality clinical reasoning trajectories for training the RRG model. The framework further incorporates Psychometric Preference Optimization (PSY-PO), which selects clinically misleading hard negative reports and uses them for preference optimization to suppress hallucinations. The authors demonstrate the effectiveness of the proposed method through experiments on public RRG benchmarks, where it outperforms several state-of-the-art methods in both generation quality and clinical consistency.

Strengths and weaknesses

Strengths

  • This work addresses the central challenge of hallucination reduction in radiology report generation, which is timely and clinically important. The motivation is clear: fluent but clinically incorrect reports can seriously undermine the reliability of automated RRG systems.
  • The paper proposes a novel self-evolving radiology skill repository that guides the teacher model in generating clinical reasoning trajectories. The dynamic evolution loop is an interesting design, as it attempts to refine reasoning supervision based on failure cases rather than relying on static prompts or fixed pseudo-labels.
  • The proposed PSY-PO is also a technically interesting contribution. By introducing Item Response Theory into preference optimization, the paper provides a principled way to model hallucinated reports as test items and historical checkpoints as examinees. This gives the method a stronger statistical foundation for selecting clinically misleading hard negatives than heuristic negative sampling approaches.

Weaknesses

  • The evidence for hallucination reduction is somewhat indirect. The qualitative examples illustrate fewer clinically misleading statements, but they do not amount to a rigorous hallucination evaluation. The paper does not report a radiologist-led review of hallucinated findings, a blinded clinical assessment, or a dedicated hallucination rate. Therefore, the claim that the method reduces hallucinations is mainly supported by NLG and CE metrics indirectly, rather than by direct expert validation of hallucination errors.
  • The proposed framework depends substantially on the quality of the teacher model. As the authors also acknowledge in the limitations, the teacher model’s medical knowledge coverage and generation stability can affect the quality of the generated clinical reasoning trajectories. This raises questions about how robust the method would be under different teacher models, weaker teachers, or teacher-generated reasoning with clinical inaccuracies.
Questions
  • In Table 2, is Rep SFT simply the baseline model trained with report-only supervision? If so, its performance appears stronger than several state-of-the-art methods reported in Table 3. Could the authors clarify the main source of this strong baseline performance?
  • The method also relies on the assumption that the teacher-generated reasoning trajectories are clinically aligned with the final ground-truth reports. Could the authors discuss what happens when the teacher's reasoning contains extra findings, misses findings, or includes content inconsistent with the report? Such cases could potentially introduce noisy supervision and harm the subsequent report-generation training.
Limitations

Most limitations are already discussed in the paper, but the indirect nature of the hallucination-reduction evidence and the lack of validation by medical experts should be addressed more thoroughly.

Final justification

The authors have addressed most of my concerns. In particular, I appreciate their substantial effort in conducting a radiologist-based human evaluation, which provides more direct and clinically meaningful evidence of hallucination reduction and further strengthens the overall evaluation. Therefore, I keep my initial rating of "Accept".

Formatting concerns

NA

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Question 1: Yes, Rep SFT is the baseline model trained solely with report-only supervision. Its strong performance mainly stems from the medical-specific visual encoder and LLM-based decoder. In contrast, several earlier methods in Table 3 employ generic CNN/ViT encoders pretrained on ImageNet and Transformer decoders. Therefore, our baseline possesses stronger medical visual representation and contextual language modeling capabilities. Even without the proposed modules, Rep SFT outperforms several earlier methods. Moreover, compared with DVAF, which also adopts a strong medical visual encoder, and MediVLM, which employs an LLM-based decoder, our full method still achieves further performance gains. This indicates that the improvements are not solely attributable to a stronger baseline architecture, but also demonstrate the effectiveness of the proposed method.


Question 2: Thank you for the constructive suggestion. We conducted a small-scale audit of the clinical reasoning trajectories under fixed model configurations and experimental settings. For automatic evaluation, 500 cases were randomly sampled from the pooled MIMIC-CXR and IU X-Ray datasets and assessed by GPT-5.5 as the LLM judge. For manual evaluation, an independent sample of 100 cases from the same pooled data was reviewed by five radiologists. Specifically, using the reference radiology reports as the evaluation basis, GPT-5.5 assigned separate scores from 0 to 10 for image-faithfulness and reasoning quality. Image-faithfulness measures the consistency between the statements in a reasoning trajectory and the imaging findings described in the reference report, whereas reasoning quality assesses the soundness of the reasoning process and whether its conclusions are adequately supported by relevant evidence. For the manual audit, image-faithfulness was graded as Fully Faithful = 1.0, Mostly Faithful = 0.6, Partially Faithful = 0.3, and Unfaithful = 0. Reasoning quality was graded as Sound Reasoning = 1.0, Mostly Sound Reasoning = 0.75, Partially Sound Reasoning = 0.5, Flawed Reasoning = 0.25, and Invalid Reasoning = 0. The table below reports the automatic and human evaluation results for the Initial Reasoning and the SECR-evolved Reasoning, where higher scores indicate better image-faithfulness and reasoning quality. The results show that SECR achieves clear improvements on both dimensions. .


Limitation 1: Thank you for the constructive suggestion. We agree that the original evaluation provides relatively indirect evidence of hallucination reduction and lacks validation by medical experts. To directly address this concern, we have added a clinically meaningful hallucination evaluation with radiologist-based human assessment. We have stratified and randomly sampled 50 cases from each of the MIMIC-CXR and IU X-Ray test sets. These labels are used solely for case sampling and are not involved in model training or hyperparameter tuning. We have further conducted an expert evaluation involving five radiologists, who independently assessed the hallucination severity and clinical usefulness of the reports generated for the sampled cases. Hallucination severity is scored as follows: Correct Statement = 0, Mild Hallucination = 0.4, Moderate Hallucination = 0.7, and Severe Hallucination = 1. Clinical usefulness is scored as follows: Clinically Acceptable = 1, Nearly Acceptable = 0.75, Moderately Acceptable = 0.5, Unacceptable = 0.25, and Unusable = 0. We have also employed the GREEN metric [a] to evaluate factual correctness on the same cases. The table below reports the results of the ablation variants and several representative advanced methods on these three metrics, where lower hallucination severity is better, whereas higher clinical usefulness and GREEN scores are better. The results show that our method achieves better overall performance in terms of hallucination severity, clinical usefulness, and factual correctness.

Different Modules and Methods MIMIC-CXR GREEN ↑ MIMIC-CXR Hallucination Severity ↓ MIMIC-CXR Clinical Usefulness ↑ IU X-Ray GREEN ↑ IU X-Ray Hallucination Severity ↓ IU X-Ray Clinical Usefulness ↑
Baseline 0.283 0.579 0.535 0.612 0.501 0.695
+SECR w/o Evo 0.313 0.546 0.590 0.630 0.427 0.650
+SECR 0.340 0.438 0.645 0.654 0.295 0.705
+PSY-PO 0.351 0.367 0.695 0.691 0.224 0.755
COMG + RL [6] 0.298 0.331 0.620 0.664 0.188 0.710
R2Gen-Mamba [34] 0.334 0.359 0.675 0.685 0.260 0.685
Ours 0.371 0.295 0.755 0.712 0.120 0.825
Authors · CommentOpenReview ↗

Correction to the Response to Reviewer w3ai's Question 2

Dear Area Chair and Reviewers,

We sincerely apologize for the incorrect response to Reviewer w3ai’s Question 2 in our previous rebuttal and would like to provide the corrected response below:

Corrected response for Reviewer w3ai’s Question 2: Thank you for the constructive suggestion. Directly internalizing teacher-generated reasoning that contains additional findings, omits findings, or conflicts with the supervision provided by the report GT could indeed introduce noisy supervision and adversely affect subsequent report generation. Importantly, such problematic reasoning trajectories are not directly used as the final supervision for internalization. The Dynamic Evolution Loop first compares the skill-invocation results in the teacher-generated trajectories with the supervision derived from the report GT to identify inconsistent trajectories. It then revises the corresponding RadSkills using the report GT and guides the teacher model to regenerate more accurate reasoning trajectories. The GRG module subsequently internalizes these evolved trajectories, thereby reducing the impact of reasoning noise. As shown in Appendix Fig. C.8, as RadSkills progressively self-evolve, the number of detected trajectories with failed skill invocation decreases from 1,272 to 68, corresponding to a cumulative correction rate of 94.7%. This indicates that most identified errors can be successfully corrected. Although a small number of undetected clinical inconsistencies may still remain, their prevalence is limited. In future work, stronger teacher models or additional self-evolution rounds could be adopted to further reduce noise in teacher-generated reasoning trajectories.

Furthermore, we have conducted additional experiments to evaluate the impact of reasoning trajectories generated by teacher models of different scales and using different prompt styles on report generation performance, as shown in the table below. “Concise” denotes a simplified prompt that preserves the task objective and output format while removing detailed generation rules, constraints, and in-context examples, retaining only the core task instructions.

Teacher Model Prompt Style BLEU-4 METEOR ROUGE-L Precision Recall F1
9B Ours 0.241 0.230 0.395 0.603 0.551 0.576
9B Concise 0.240 0.223 0.396 0.596 0.553 0.573
4B Ours 0.233 0.219 0.386 0.561 0.528 0.544
4B Concise 0.238 0.221 0.388 0.572 0.519 0.544
Authors · CommentOpenReview ↗

Kind Reminder

Dear Reviewer w3ai,

We sincerely appreciate your helpful and constructive comments. As the discussion period is nearing the end, we would greatly appreciate it if you could let us know whether our rebuttal addresses your concerns.

Reviewer oecCOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes a three-stage framework for radiology report generation (RRG) to address the hallucination problem in vision-language models. The main contributions are: 1) It proposes self-evolving clinical reasoning (SECR) by building a dynamically updated RadSkill repository and using a failure-driven evolution loop to generate clinical reasoning via a teacher model; 2) It proposes a grounded report generation (GRG) stage by internalizing explicit reasoning into the baseline model’s implicit diagnostic intuition using SFT; 3) It proposes a psychometric preference optimization (PSY-PO) method based on Item Response Theory (IRT) to select clinically misleading “hard negative” reports.

Strengths and weaknesses

For Quality, this paper is complete and well-structured. The proposed method description is generally clear and the evaluations (especially the ablation study and qualitative results) are well designed. However, the paper doesn’t report error bars or statistical significance tests (Tables 1-3), which makes the quantitative comparison less confident. One of the main contributions of this work is to internalize the explicit reasoning into the baseline model's implicit diagnosis, but the verification is limited.

For Clarity, the paper is generally clear, and it provides more details in the Appendix, such as the prompt to LLMs.

For Significance, this paper targets an important problem in the radiology report generation task: reducing hallucinations. However, to make the proposed method really be validated in real clinical cases, it still needs human evaluation, besides the current metrics.

For Originality, this paper combines multiple existing components (e.g., DPO, teacher-student learning, etc), and proposes to use IRT in PSY-PO. However, discussions and comparisons with other reasoning-enhanced RRG methods are expected, such as RadAgent [1], CheXOne [2], and ORGAN [3].

[1] Zhang K, Barrett C D, Kim J, et al. RadAgents: Multimodal Agentic Reasoning for Chest X-ray Interpretation with Radiologist-like Workflows[J]. arXiv preprint arXiv:2509.20490, 2025.

[2] Zhang Y, Wang C, Gao Y, et al. A Reasoning-Enabled Vision-Language Foundation Model for Chest X-ray Interpretation[J]. arXiv preprint arXiv:2604.00493, 2026.

[3] Hou W, Xu K, Cheng Y, et al. ORGAN: Observation-guided radiology report generation via tree reasoning[C]//Proceedings of the 61st Annual Meeting of the Association for Computational Linguistics (Volume 1: Long Papers). 2023: 8108-8122.

Questions

My main questions are as follows:

  1. One main claim of the paper is about reducing hallucination and increasing trustworthiness, but current evaluations are based on NLG metrics and CE metrics, without human analysis. Is it possible to provide a small radiologist or expert evaluation of the factual correctness, hallucination severity, or clinical usefulness?

  2. One main contribution of the paper is to improve the reasoning of VLM models in RRG. However, current comparisons mainly focus on the pretrained VLM, contrastive learning, etc. Could the authors discuss and compare with existing reasoning-focused RRG methods as baselines, such as RadAgent [1], CheXOne [2], ORGAN [3], and CoMT [4]?

  3. Current quantitative results in Tables 1-3 do not include error bars and significance analysis. Could the authors include them for a more robust comparison? Moreover, the paper uses CheXbert to extract 14 clinical observations but reports only the overall performance. Could the authors provide detailed results per observation and discuss the influence on common and rare cases, separately?

[1] Zhang K, Barrett C D, Kim J, et al. RadAgents: Multimodal Agentic Reasoning for Chest X-ray Interpretation with Radiologist-like Workflows[J]. arXiv preprint arXiv:2509.20490, 2025.

[2] Zhang Y, Wang C, Gao Y, et al. A Reasoning-Enabled Vision-Language Foundation Model for Chest X-ray Interpretation[J]. arXiv preprint arXiv:2604.00493, 2026.

[3] Hou W, Xu K, Cheng Y, et al. ORGAN: Observation-guided radiology report generation via tree reasoning[C]//Proceedings of the 61st Annual Meeting of the Association for Computational Linguistics (Volume 1: Long Papers). 2023: 8108-8122.

[4] Jiang Y, Chen J, Yang D, et al. Comt: Chain-of-medical-thought reduces hallucination in medical report generation[C]//ICASSP 2025-2025 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP). IEEE, 2025: 1-5.

Limitations

No. Although the authors acknowledge limitations in the paper, such as limited modality (CXR), limited organ and disease, generalization ability to more complex clinical settings, and the dependence on the teacher model, there are other limitations not been adequately addressed yet.

  1. The paper aims to reduce hallucination and improve clinical trustworthiness, but the validation is still mainly based on automatic metrics, lacking radiologist evaluation to assess the hallucination severity and clinical trustworthiness.

  2. Since the paper relies heavily on a teacher model for clinical reasoning generation, still evolution, and hallucinated negative construction, the paper should discuss the dependence on teacher-model quality and sensitivity to prompt design.

  3. The paper should discuss the relationship to existing reasoning-enhanced RRG methods and show whether the proposed reasoning internization provides advantages over prior reasoning approaches.

Final justification

The authors addressed my questions and concerns.

Formatting concerns

I didn't notice any major issues with the paper's formatting.

4 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Question 1 & Limitation 1: Thank you for the constructive suggestion. To complement the human evaluation, we have randomly sampled 50 cases from each of the MIMIC-CXR and IU X-Ray test sets. These labels were used solely for case selection and were not involved in model training or hyperparameter tuning. We have further conducted an expertevaluation involving five radiologists, who independently assessed the hallucination severity andclinical usefulness of the reports generated for the 50 sampled cases. Hallucination severity is scored as follows: Correct Statement = 0, Mild Hallucination = 0.4, Moderate Hallucination = 0.7, and Severe Hallucination = 1. Clinical usefulness is scored as follows: Clinically Acceptable = 1, Nearly Acceptable = 0.75, Moderately Acceptable = 0.5, Unacceptable = 0.25, and Unusable = 0. We have also employed the GREEN metric [a] to evaluate factual correctness on the same cases. The table below reports the results of each ablation variant and several representative state-of-the-art methods on these three metrics, where lower hallucination severity is better, whereas higher clinical usefulness and GREEN scores are better.

Different Modules and Methods MIMIC-CXR GREEN ↑ MIMIC-CXR Hallucination Severity ↓ MIMIC-CXR Clinical Usefulness ↑ IU X-Ray GREEN ↑ IU X-Ray Hallucination Severity ↓ IU X-Ray Clinical Usefulness ↑
Baseline 0.283 0.579 0.535 0.612 0.501 0.695
+SECR w/o Evo 0.313 0.546 0.590 0.630 0.427 0.650
+SECR 0.340 0.438 0.645 0.654 0.295 0.705
+PSY-PO 0.351 0.367 0.695 0.691 0.224 0.755
COMG + RL [6] 0.298 0.331 0.620 0.664 0.188 0.710
R2Gen-Mamba [34] 0.334 0.359 0.675 0.685 0.260 0.685
Ours 0.371 0.295 0.755 0.712 0.120 0.825

[a] Ostmeier S, Xu J, Chen Z, et al. Green: Generative radiology report evaluation and error notation[C]//Findings of the Association for Computational Linguistics: EMNLP 2024. 2024: 374–390.

Question 2 & Limitation 3: Following your suggestion, we have reproduced the results of CheXOne [2], ORGAN [3], and CoMT [4] on IU X-Ray, as reported in the table below. The results show that our method outperforms these reasoning-focused RRG methods. Specifically, ORGAN, CoMT, and CheXOne introduce reasoning supervision through a tree reasoning mechanism, hierarchical chain-based QA, and LLM-generated reasoning traces, respectively. However, they fundamentally rely on one-off static reasoning patterns and lack a mechanism to continuously refine reasoning knowledge based on the model’s diagnostic failures. In contrast, the advantage of our method lies in the Dynamic Evolution Loop, which iteratively updates RadSkills and regenerates more reliable reasoning trajectories. Moreover, GRG internalizes the evolved reasoning capability into the model, preserving the benefits of diagnostic reasoning while maintaining direct image-to-report generation and avoiding disruption of the concise, standardized language and formatting of radiologyreports by explicit reasoning text.

Question 3: We have further conducted three repeated experiments with different random seeds, with the results reported in the three tables below. The standard deviations of all evaluation metrics are below 0.01, indicating limited variation across runs and further demonstrating the effectiveness and stability of the proposed method.

Different Modules IU X-Ray BLEU-4 IU X-Ray METEOR IU X-Ray ROUGE-L IU X-Ray Precision IU X-Ray Recall IU X-Ray F1
Baseline 0.173 ± 0.010 0.203 ± 0.002 0.348 ± 0.007 0.490 ± 0.005 0.426 ± 0.003 0.456 ± 0.003
SECR w/o Evo 0.194 ± 0.003 0.210 ± 0.003 0.361 ± 0.003 0.530 ± 0.007 0.475 ± 0.009 0.500 ± 0.006
SECR 0.209 ± 0.010 0.228 ± 0.001 0.379 ± 0.009 0.550 ± 0.006 0.491 ± 0.005 0.519 ± 0.006
PSY-PO 0.212 ± 0.003 0.220 ± 0.002 0.376 ± 0.003 0.556 ± 0.007 0.518 ± 0.009 0.536 ± 0.006
Ours 0.240 ± 0.002 0.231 ± 0.002 0.395 ± 0.003 0.602 ± 0.006 0.552 ± 0.008 0.576 ± 0.005
Strategy IU X-Ray BLEU-4 IU X-Ray METEOR IU X-Ray ROUGE-L IU X-Ray Precision IU X-Ray Recall IU X-Ray F1
Rep SFT 0.173 ± 0.010 0.203 ± 0.002 0.348 ± 0.007 0.490 ± 0.005 0.426 ± 0.003 0.456 ± 0.003
Rea+Rep SFT 0.103 ± 0.005 0.143 ± 0.007 0.263 ± 0.009 0.492 ± 0.008 0.480 ± 0.002 0.486 ± 0.004
Rep→Rea SFT 0.118 ± 0.006 0.200 ± 0.003 0.314 ± 0.007 0.536 ± 0.008 0.376 ± 0.009 0.442 ± 0.004
Ours 0.209 ± 0.010 0.228 ± 0.001 0.379 ± 0.009 0.550 ± 0.006 0.491 ± 0.005 0.519 ± 0.006
Method MIMIC-CXR BLEU-4 MIMIC-CXR METEOR MIMIC-CXR ROUGE-L MIMIC-CXR Precision MIMIC-CXR Recall MIMIC-CXR F1 IU X-Ray BLEU-4 IU X-Ray METEOR IU X-Ray ROUGE-L
Ours 0.165 ± 0.003 0.181 ± 0.002 0.310 ± 0.004 0.636 ± 0.008 0.476 ± 0.010 0.546 ± 0.007 0.240 ± 0.002 0.231 ± 0.002 0.395 ± 0.003

Furthermore, the table below compares our method with the Baseline and two reproduced SOTA methods on MIMIC-CXR, CheXOne and R2GenMAM, in terms of per-class Precision, Recall, and F1 across 14 clinical observations. Our method consistently outperforms the Baseline and both SOTA methods on all three metrics for all 14 observations. Performance gains are observed for both common observations with abundant training samples, such as Lung Opacity, Atelectasis, Edema, and Pleural Effusion, and rare observations with limited training samples, such as Pneumothorax, Enlarged Cardiomediastinum, and Fracture.

Metric Support Devices Lung Opacity Cardiomegaly Pleural Effusion Atelectasis No Finding Edema Enlarged Cardiomediastinum Consolidation Pneumonia Pneumothorax Lung Lesion Fracture Pleural Other
Ours Precision 0.807 0.602 0.700 0.760 0.545 0.232 0.612 0.152 0.483 0.351 0.553 0.381 0.502 0.407
Baseline Precision 0.731 0.585 0.694 0.754 0.517 0.226 0.606 0.055 0.112 0.345 0.354 0.261 0.034 0.101
CheXone Precision 0.785 0.523 0.581 0.702 0.474 0.144 0.568 0.082 0.207 0.183 0.551 0.273 0.500 0.000
R2GenMAM Precision 0.753 0.487 0.607 0.758 0.409 0.131 0.467 0.032 0.152 0.235 0.241 0.316 0.000 0.000
Ours Recall 0.824 0.300 0.656 0.609 0.320 0.583 0.330 0.083 0.141 0.144 0.357 0.039 0.062 0.056
Baseline Recall 0.779 0.045 0.498 0.420 0.088 0.564 0.190 0.002 0.135 0.138 0.129 0.004 0.056 0.050
CheXone Recall 0.716 0.288 0.552 0.497 0.318 0.581 0.328 0.042 0.037 0.092 0.355 0.037 0.032 0.000
R2GenMAM Recall 0.687 0.145 0.439 0.412 0.286 0.557 0.187 0.009 0.043 0.074 0.092 0.037 0.000 0.000
Ours F1 0.815 0.401 0.677 0.676 0.403 0.332 0.428 0.107 0.219 0.205 0.434 0.071 0.110 0.098
Baseline F1 0.790 0.084 0.580 0.539 0.150 0.322 0.289 0.004 0.122 0.198 0.171 0.007 0.042 0.088
CheXone F1 0.749 0.371 0.566 0.582 0.381 0.231 0.416 0.055 0.063 0.122 0.432 0.065 0.060 0.000
R2GenMAM F1 0.719 0.223 0.509 0.534 0.337 0.212 0.267 0.014 0.068 0.112 0.133 0.066 0.000 0.000

Limitation 2: Following your suggestion, we have conducted sensitivity analyses on teacher-model scale and prompt style, as reported in the table below. “Concise” denotes a simplified prompt that preserves the task objective and output format while removing detailed generation rules, constraints, and in-context examples, retaining only the core task instructions. The 9B teacher model achieves better overall performance on both NLG and CE metrics, indicating that teacher-model capacity affects clinical reasoning generation and downstream RRG performance. In contrast, varying the prompt style under a fixed teacher model causes only minor fluctuations, mainly reflecting slight trade-offs across NLG and CE metrics. These results demonstrate that our method remains stable across the tested prompt configurations.

Teacher Model Prompt Style BLEU-4 METEOR ROUGE-L Precision Recall F1
9B Ours 0.241 0.230 0.395 0.603 0.551 0.576
9B Concise 0.240 0.223 0.396 0.596 0.553 0.573
4B Ours 0.233 0.219 0.386 0.561 0.528 0.544
4B Concise 0.238 0.221 0.388 0.572 0.519 0.544
Authors · CommentOpenReview ↗

Supplementary Table for Question 2 & Limitation 3 from Reviewer oecC

For completeness, we supplement our previous rebuttal response to Reviewer oecC's Question 2 & Limitation 3 with the table below, which presents the MIMIC-CXR and IU X-Ray results of representative reasoning-focused RRG methods. * denotes results reproduced by us.

Methods MIMIC-CXR BLEU-4 MIMIC-CXR METEOR MIMIC-CXR ROUGE-L MIMIC-CXR Precision MIMIC-CXR Recall MIMIC-CXR F1 IU X-Ray BLEU-4 IU X-Ray METEOR IU X-Ray ROUGE-L
CheXOne [2]* 0.112 0.154 0.287 0.403 0.364 0.383 0.171 0.203 0.382
CoMT [4]* 0.106 0.134 0.247 0.398 0.356 0.376 0.140 0.171 0.324
ORGAN [3] 0.123 0.162 0.293 0.416 0.385 0.418 0.195 0.205 0.399
Ours 0.165 0.181 0.310 0.636 0.476 0.546 0.241 0.230 0.395
Authors · CommentOpenReview ↗

Supplementary MIMIC-CXR Error-Bar Results for Tables 1–2 in Response to Reviewer oecC's Question 3

For completeness, we supplement our previous rebuttal response to Reviewer oecC's Question 3 with the corresponding MIMIC-CXR Error-Bar Results for Tables 1 and 2, as presented below.

Different Modules MIMIC-CXR BLEU-4 MIMIC-CXR METEOR MIMIC-CXR ROUGE MIMIC-CXR Precision MIMIC-CXR Recall MIMIC-CXR F1
Baseline 0.106 ± 0.003 0.138 ± 0.002 0.256 ± 0.003 0.585 ± 0.005 0.333 ± 0.003 0.425 ± 0.003
SECR w/o Evo 0.126 ± 0.003 0.160 ± 0.002 0.287 ± 0.003 0.621 ± 0.003 0.441 ± 0.004 0.516 ± 0.003
SECR 0.146 ± 0.003 0.171 ± 0.004 0.292 ± 0.001 0.630 ± 0.004 0.468 ± 0.007 0.537 ± 0.003
PSY-PO 0.155 ± 0.003 0.175 ± 0.003 0.303 ± 0.004 0.617 ± 0.003 0.446 ± 0.003 0.518 ± 0.003
Ours 0.165 ± 0.003 0.181 ± 0.002 0.310 ± 0.004 0.636 ± 0.008 0.476 ± 0.010 0.546 ± 0.007
Strategy MIMIC-CXR BLEU-4 MIMIC-CXR METEOR MIMIC-CXR ROUGE-L MIMIC-CXR Precision MIMIC-CXR Recall MIMIC-CXR Clinical F1
Rep SFT 0.106 ± 0.003 0.138 ± 0.002 0.256 ± 0.003 0.585 ± 0.005 0.333 ± 0.003 0.425 ± 0.003
Rea+Rep SFT 0.102 ± 0.003 0.123 ± 0.004 0.221 ± 0.005 0.456 ± 0.006 0.313 ± 0.002 0.371 ± 0.007
Rep→Rea SFT 0.108 ± 0.005 0.115 ± 0.002 0.214 ± 0.004 0.436 ± 0.008 0.304 ± 0.009 0.358 ± 0.006
Ours 0.146 ± 0.003 0.171 ± 0.004 0.292 ± 0.001 0.630 ± 0.004 0.468 ± 0.007 0.537 ± 0.003
Authors · CommentOpenReview ↗

Kind Reminder

Dear Reviewer oecC,

We sincerely appreciate your helpful and constructive comments. As the discussion period is nearing the end, we would greatly appreciate it if you could let us know whether our rebuttal addresses your concerns.

Best Regards,

Authors

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…