potentialpaper

Incentivizing Medical Vision Capabilities from Large-Scale Multimodal Pre-training

Junying Chen, Zhenyang Cai, Yunjin Yang, Kunyuan Cai, Rongsheng Wang, Xidong Wang, Geyang Yu, Xiangyi Feng, Benyou Wang

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. Building medical vision capabilities through large-scale pre-training and reinforcement learning.

Abstract. Building capable medical vision-language models (VLMs) is challenging due to the scarcity of domain data and the difficulty of eliciting pre-trained medical visual knowledge. We present HuatuoGPT-Vision-2, a medical VLM built on a simple yet effective recipe: large-scale multimodal pre-training followed by reinforcement learning (RL). We first construct PubMedVision-Plus, the largest medical image-text dataset with 60M pairs from public PubMed literature, along with a clean 12M high-quality subset. After pre-training on this data, we find that traditional supervised fine-tuning (SFT) struggles to elicit the pre-trained knowledge. In contrast, by applying RL with verifiable and rubric-based instances synthesized directly from the pre-training data, we successfully incentivize the model to use this pre-trained medical visual knowledge. On PubMed-derived data, HuatuoGPT-Vision-2 outperforms similarly sized VLMs on multiple medical benchmarks and expert evaluations, significantly narrowing the gap between medical VLMs and leading proprietary VLMs. We hope these data, models, and findings can help accelerate open research on capable medical VLMs. Data, code, and models are available at https://github.com/FreedomIntelligence/HuatuoGPT-Vision-2.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
2 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (oral)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (oral) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:42 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (oral)
Read decision
Meta-review

Summary. HuatuoGPT-5 is a medical vision-language model built by large-scale medical multimodal pre-training followed directly by reinforcement learning. Figure-caption pairs from 15.2M PubMed papers form PubMedVision-Plus (~60M pairs), filtered in three stages to a 12M-pair subset, PubMedVision-Plus-Core. PubMedVision-RL is synthesized from the same corpus: multiple-choice items with verifiable rewards plus open-ended items with rubric rewards, scored by a distilled scorer at 91.5% agreement with GPT-4.1. Qwen3-VL backbones at 8B and 32B are continued-pretrained then trained with GRPO. Across eight medical benchmarks the paper reports average gains of +9.9 (8B) and +10.1 (32B) with general capability preserved, plus a new rubric benchmark, MedMM-ExpertRubric, and a physician preference study.

Strengths. All three reviewers credit the data contribution: PubMedVision-Plus and -Core are called valuable for the community, a meaningful contribution with a transparent filtering pipeline, and a significant open data contribution. Two reviewers credit the evaluation breadth, including general-capability preservation and rubric and physician-preference evaluation beyond multiple-choice accuracy; one adds that the results are strong, the ablations useful and the contamination and general-capability handling careful. The Figure 1 pilot design, gains on non-PubMed benchmarks, and the reward-complementarity analysis are also credited.

Weaknesses.

  1. The RL-versus-SFT claim is not isolated: the SFT baseline uses Qwen3-VL-32B-Instruct answers on the same prompts, which controls prompt set and volume but leaves teacher and target-answer quality confounded. A stronger teacher (Gemini-3-Pro, GPT-5.4) might narrow the gap, so the evidence supports "this specific RL setup is better than this specific SFT setup" more than the general claim.
  2. No statistical uncertainty on the main results; bootstrap confidence intervals over evaluation examples are feasible even where repeated training runs are not. A second reviewer also asks for confidence intervals on the open-ended evaluation.
  3. Dataset quality is asserted rather than measured: no physician-reviewed gold-standard subset for PubMedVision-Plus-Core, no precision/recall or modality-specific quality estimates for filtering.
  4. Reliance on model-based judging: scoring is by GPT-4.1 or a trained small VLM scorer, and the physician study has only 100 questions and two physicians; larger human validation, inter-rater agreement and failure-case analysis are requested. A second reviewer shares the scorer concern, finding 91.5% agreement insufficient.
  5. Reproducibility, raised by two reviewers: the checklist marks open access to data and code "No" while promising full release, and GPT-5.4/GPT-4.1 call counts, label cost and wall-clock overhead are never reported.
  6. No failure-mode analysis: failure modes should be disclosed and categorised by imaging modality for an open-source medical model. A second reviewer also asks for failure cases.
  7. No clinical report-style or non-PubMed transfer evaluation, with MIMIC-CXR, IU-Xray, CheXpert Plus, ReXGradient or ReXVQA suggested.
  8. No RL data-scale ablation: whether 20K or 35K instances would suffice.
  9. Limited methodology novelty, the SFT + RL recipe being called widely used; and underexplained details: sequence packing and masking, loss placement, "seed data", "task-specific heads", the HuatuoGPT-Vision-7B / HuatuoGPT-5 naming, Figure 2 typos and missing Table 2 citations.

Questions to address in the author response.

  1. Can you add a stronger-teacher SFT baseline (Gemini-3-Pro or GPT-5.4) on the same prompts, at 8B scale at minimum?
  2. Can you report bootstrap confidence intervals over evaluation examples?
  3. Can you give quality metrics for PubMedVision-Plus-Core from a physician-reviewed gold-standard subset, with filtering precision/recall and error examples?
  4. Can you give a failure analysis by modality, anatomical region and question type, including cases where RL degrades performance, plus validation of the rubric scorer? (raised by all three reviewers)
  5. What will be released, under what license or access terms, and at what approximate cost for the GPT-5.4/GPT-4.1 pipeline? (raised by two reviewers)

The panel is unanimously positive and this submission is heading toward acceptance after solving reviewers concerns.

Final justification

All the previous questions have been addressed during the rebuttal, with confirmation from most reviewers. Overall, this paper presents HuatuoGPT-5, a medical vision-language model built via large-scale medical multimodal pre-training followed directly by reinforcement learning, which we hope is a significant contribution to the open-source medical VLM community.

Area Chair Z5K8 · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

Summary. HuatuoGPT-5 is a medical vision-language model built by large-scale medical multimodal pre-training followed directly by reinforcement learning. Figure-caption pairs from 15.2M PubMed papers form PubMedVision-Plus (~60M pairs), filtered in three stages to a 12M-pair subset, PubMedVision-Plus-Core. PubMedVision-RL is synthesized from the same corpus: multiple-choice items with verifiable rewards plus open-ended items with rubric rewards, scored by a distilled scorer at 91.5% agreement with GPT-4.1. Qwen3-VL backbones at 8B and 32B are continued-pretrained then trained with GRPO. Across eight medical benchmarks the paper reports average gains of +9.9 (8B) and +10.1 (32B) with general capability preserved, plus a new rubric benchmark, MedMM-ExpertRubric, and a physician preference study.

Strengths. All three reviewers credit the data contribution: PubMedVision-Plus and -Core are called valuable for the community, a meaningful contribution with a transparent filtering pipeline, and a significant open data contribution. Two reviewers credit the evaluation breadth, including general-capability preservation and rubric and physician-preference evaluation beyond multiple-choice accuracy; one adds that the results are strong, the ablations useful and the contamination and general-capability handling careful. The Figure 1 pilot design, gains on non-PubMed benchmarks, and the reward-complementarity analysis are also credited.

Weaknesses.

  1. The RL-versus-SFT claim is not isolated: the SFT baseline uses Qwen3-VL-32B-Instruct answers on the same prompts, which controls prompt set and volume but leaves teacher and target-answer quality confounded. A stronger teacher (Gemini-3-Pro, GPT-5.4) might narrow the gap, so the evidence supports "this specific RL setup is better than this specific SFT setup" more than the general claim.
  2. No statistical uncertainty on the main results; bootstrap confidence intervals over evaluation examples are feasible even where repeated training runs are not. A second reviewer also asks for confidence intervals on the open-ended evaluation.
  3. Dataset quality is asserted rather than measured: no physician-reviewed gold-standard subset for PubMedVision-Plus-Core, no precision/recall or modality-specific quality estimates for filtering.
  4. Reliance on model-based judging: scoring is by GPT-4.1 or a trained small VLM scorer, and the physician study has only 100 questions and two physicians; larger human validation, inter-rater agreement and failure-case analysis are requested. A second reviewer shares the scorer concern, finding 91.5% agreement insufficient.
  5. Reproducibility, raised by two reviewers: the checklist marks open access to data and code "No" while promising full release, and GPT-5.4/GPT-4.1 call counts, label cost and wall-clock overhead are never reported.
  6. No failure-mode analysis: failure modes should be disclosed and categorised by imaging modality for an open-source medical model. A second reviewer also asks for failure cases.
  7. No clinical report-style or non-PubMed transfer evaluation, with MIMIC-CXR, IU-Xray, CheXpert Plus, ReXGradient or ReXVQA suggested.
  8. No RL data-scale ablation: whether 20K or 35K instances would suffice.
  9. Limited methodology novelty, the SFT + RL recipe being called widely used; and underexplained details: sequence packing and masking, loss placement, "seed data", "task-specific heads", the HuatuoGPT-Vision-7B / HuatuoGPT-5 naming, Figure 2 typos and missing Table 2 citations.

Questions to address in the author response.

  1. Can you add a stronger-teacher SFT baseline (Gemini-3-Pro or GPT-5.4) on the same prompts, at 8B scale at minimum?
  2. Can you report bootstrap confidence intervals over evaluation examples?
  3. Can you give quality metrics for PubMedVision-Plus-Core from a physician-reviewed gold-standard subset, with filtering precision/recall and error examples?
  4. Can you give a failure analysis by modality, anatomical region and question type, including cases where RL degrades performance, plus validation of the rubric scorer? (raised by all three reviewers)
  5. What will be released, under what license or access terms, and at what approximate cost for the GPT-5.4/GPT-4.1 pipeline? (raised by two reviewers)

The panel is unanimously positive and this submission is heading toward acceptance after solving reviewers concerns.

Final justification

All the previous questions have been addressed during the rebuttal, with confirmation from most reviewers. Overall, this paper presents HuatuoGPT-5, a medical vision-language model built via large-scale medical multimodal pre-training followed directly by reinforcement learning, which we hope is a significant contribution to the open-source medical VLM community.

1 comment
Authors · CommentOpenReview ↗

Response to Meta-Review

Dear Area Chair,

We sincerely appreciate your thoughtful meta-review and the reviewers' detailed, constructive feedback throughout the review process. We are especially grateful for the panel's recognition of our data contribution and evaluation breadth, and for the concrete suggestions that have helped us strengthen the work.

Below we summarize our responses to each meta-review point, with references to the specific reviewer replies for your convenience.

  • Summary of Responses to Meta-Review Questions
# Question Addressed in Summary
Q1 Stronger-teacher SFT baseline LFjR Q1 Added GPT-5.4-high / Gemini-3-Pro SFT; RL still +7.7 avg points ahead.
Q2 Bootstrap confidence intervals LFjR Q2 / 7oXi Q2 Added 10,000 bootstrap CIs for the main benchmarks and MedMM-ExpertRubric.
Q3 PubMedVision-Plus-Core quality audit LFjR Q4 Physician gold-standard audit: 93.3% precision, 84.3% recall, 88.6% F1.
Q4 Failure analysis + rubric scorer validation xwwJ Q1 / LFjR Q3 / 7oXi Q2 Modality/anatomy/question-type breakdown; scorer: 88.7% physician agreement, κ=0.751.
Q5 Release plan, license, API cost 7oXi Q1 / LFjR Q6 Asset release table; API cost ~$15.46K; scorer adds 8% overhead.
  • Summary of Responses to Meta-Review Weaknesses
# Weakness Addressed in Summary
W1 RL-vs-SFT confounded by teacher quality LFjR Q1 Stronger teachers close gap minimally; RL +7.7 pts.
W2 No statistical uncertainty LFjR Q2 / 7oXi Q2 Bootstrap CIs added; paired gain CIs exclude zero.
W3 Dataset quality not measured LFjR Q4 Physician audit with per-stage precision/recall/F1 added.
W4 Model-based judging reliability 7oXi Q2 / LFjR Q3 Human validation: GPT-4.1 90.3%, 8B scorer 88.7% vs physicians.
W5 Reproducibility / release 7oXi Q1 / LFjR Q6 Release plan, licenses, API cost now detailed.
W6 No failure-mode analysis xwwJ Q1 Modality/anatomy/question-type breakdown; regression cases identified.
W7 No clinical report transfer LFjR Q5 MIMIC-CXR, IU-Xray, CheXpert Plus added.
W8 No RL data-scale ablation xwwJ Q2 35K RL data yields competitive results (68.2 vs 68.5 avg).
W9 Methodology novelty / implementation details 7oXi W3 / LFjR Q7 Reframed as paradigm contribution; clarified packing, terminology, naming, typos, citations.

We have carefully considered each concern and provided additional analyses where requested, including new experiments, human validation, failure-case categorization, and planned release details. We hope these additions address the issues raised, and we will incorporate them carefully into the revised manuscript.

We are deeply grateful for the time and expertise you and the reviewers have devoted to our work.

Sincerely,

The Authors

Reviewer xwwJOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper presents HuatuoGPT-5, a medical vision-language model built on a two-stage recipe: large-scale medical multimodal pre training followed by reinforcement learning (RL). To address data scarcity, the authors construct PubMedVision-Plus (60M image-caption pairs from PubMed) and filter it to a 12M high-quality subset (PubMedVision-Plus-Core) for pre-training. To address capability activation, they synthesize RL training instances (verifiable +rubric-based) directly from pre-training captions, forming PubMedVision-RL (70K instances). A controlled pilot study shows RL elicits pre-trained knowledge more effectively than SFT, with the gap widening as pre-training scales up. HuatuoGPT-5 (8B and 32B) achieves state-of-the-art results among open-source medical VLMs and narrows the gap to proprietary models like GPT-5.4-mini.

Strengths and weaknesses

Strength

  • Well-designed pilot study: The controlled comparison in Figure 1 uses the same prompts for both SFT and RL across multiple pre-training scales. The diverging curves cleanly demonstrate that RL's advantage grows with more pre-training, isolating the training mechanism as the key variable.
  • Significant open data contribution
  • Strong generalization evidence: Consistent gains on benchmarks not sourced from PubMed demonstrate the model learns transferable medical visual understanding, not just memorization of pre-training data.
  • nformative reward complementarity analysis: Verifiable rewards help closed-ended tasks, rubric rewards help open-ended tasks, and their combination yields the best performance.

I do not find major serious weakness. However, as an opensource medical model, I think it would be crucial to disclose / categorized the failure mode: For example, what kind of image modality the model struggle on (Radiology? Pathology, CT?).

Questions
  • Could you provide a failure analysis? Specifically, on which modalities, anatomical regions, or question types does RL fail to activate pre-trained knowledge? Are there cases where RL degrades performance compared to the pre-trained model?
  • What is the effect of RL data scale? Would 20K or 35K instances achieve similar gains, or is 70K necessary?
Limitations

yes (in appendix)

Final justification

The author clear up my questions. I remain my original score 5 (accept)

Formatting concerns

no

3 comments
Authors · CommentOpenReview ↗

Rebuttal by Authors (Part 1)

We sincerely thank the reviewer for the positive assessment and for identifying the two useful diagnostic additions: where RL still fails and how much RL data is actually needed. We add both below.

Q1 & W1. Failure analysis by modality, anatomy, and question type; are there cases where RL degrades performance?

We agree that disclosing failure modes is particularly important for an open medical model.

1. Failure analysis by modality, anatomy, and question type

The intermediate pre-training checkpoint uses caption prediction and is not directly instruction-evaluable. We therefore compare HuatuoGPT-5-8B (Pre-training + RL) with its Qwen3-VL-8B-Instruct base on a 2,000-example stratified audit set from GMAI-MMBench and OmniMedVQA, with metadata normalized into shared categories.

To gauge how well RL activates capabilities, we also report pre-training volumes per modality/anatomy from the 12M-pair PubMedVision-Plus-Core corpus. Generally, more data should lead to stronger activation. Results are as follows:

(1) Modality.

Modality Samples Approx. pairs Gain vs. base
MRI 538 2.46M +10.2
CT 384 2.07M +11.2
X-ray 181 1.51M +2.8
Digital photography* 118 1.36M +6.8
Microscopy/pathology 250 1.26M +2.4
Ophthalmic imaging 237 0.31M +2.5
Endoscopy 147 0.30M +3.4

Only modalities with >100 samples are reported. "Samples" = audit set size per category; "Approx. pairs" = pre-training volume from PubMedVision-Plus-Core.

(2) Anatomy.

Anatomy Samples Approx. pairs Gain vs. base
Abdomen/pelvis 383 1.93M +13.8
Chest 279 1.73M +2.5
Head/neck/oral 167 1.66M +14.4
Spine/bone 326 1.19M +3.4
Cell 228 0.93M +0.88
Skin 118 0.52M +5.9
GI tract 106 0.30M +0.9

Only anatomies with >100 samples are reported. "Samples" = audit set size per category; "Approx. pairs" = pre-training volume from PubMedVision-Plus-Core.

Observations. Gains generally correlate with pre-training volume. For example, MRI and Abdomen/pelvis, both with large volumes, show strong improvements. However, some cases stand out as suboptimal:

  • Large volume but modest gain: X-ray, Cell, Chest.
  • Small volume and minimal gain: GI tract. These suggest room for improving RL activation.

(3) Question type.

Question type n Base Pre-training + RL Gain vs. base
Diagnosis/interpretation 983 70.8 78.2 +7.4
Anatomy/localization 427 61.8 74.9 +13.1
Attribute/characterization 165 57.6 61.2 +3.6
Modality recognition 145 98.6 97.9 -0.7
Finding presence 122 52.5 77.0 +24.6
Instrument/procedure 101 33.7 37.6 +4.0
Severity/grading 57 36.8 35.1 -1.8

Observations. Modality recognition shows little gain, likely due to base-model saturation (98.6%). Severity/grading also sees a slight drop, though its small sample size (n=57) may introduce volatility. Still, this category clearly has significant room for improvement. To directly answer the reviewer's question: yes, RL degrades performance on specific categories.

2. Representative failure cases

Manual inspection identifies several recurring failure modes:

Failure case Base to Pre-training + RL regression Likely cause
Normal or near-normal chest X-ray Correctly reports no clear lesion -> introduces a subtle unsupported opacity PubMed publication bias favors positive and unusual findings, underrepresenting truly normal cases
Dense multi-panel CT/endoscopy figure Correctly links a finding to one panel -> assigns it to another panel Journal captions often describe panels jointly, while the benchmark requires exact panel correspondence
Axial CT laterality question Correctly localizes the lesion -> reverses left and right Fine-grained spatial grounding is weakly supervised by caption-level rewards
Low-resolution fundus or pathology image Gives a cautious interpretation -> produces an over-specific diagnosis Rare visual distribution, limited resolution, and a bias toward named diagnoses in source articles

We will add a dedicated failure-analysis section in the revision, including slice-level results, negative post-RL flips, and representative examples. We will also state prominently that HuatuoGPT-5 is intended only as a general medical multimodal model for academic research. It is not intended for diagnosis, treatment, triage, or any other medical decision, and its outputs must not replace qualified clinical judgment.

Authors · CommentOpenReview ↗

Rebuttal by Authors (Part 2)

Q2. Is the full 70K medical RL set necessary?

Thank you for raising this valuable question. RL data scale remains an important research topic. In fact, we also experimented with less RL data during development. Specifically, we evaluated a run using a half-size subset (35K, randomly sampled) while keeping all other factors constant and maintaining the same general-data mixing ratio. The results are shown below:

Unique medical RL instances GMAI-MMBench OmniMedVQA 8-benchmark Avg. General benchmark Avg.
35K (half data) 62.5 84.7 68.2 63.8
70K (default) 63.2 84.5 68.5 64.9

The 35K subset performs close to the 70K setting on the eight-benchmark average (68.2 vs. 68.5), although individual benchmarks show small non-monotonic differences. This suggests that practitioners may achieve competitive results with substantially less RL data.

Nevertheless, we chose the 70K setting for two reasons: (1) more data caused no consistent degradation in the reported metrics, and (2) more instances increases diversity. By releasing the full 70K dataset, we hope to provide the community with more flexibility for future RL scale-up Exploration.

Closing.

We again thank the reviewer for recognizing the value of our data contribution and RL reward design. We hope our datasets and recipe will benefit the broader community.

Authors · CommentOpenReview ↗

Thank You and Follow-up

Dear Reviewer xwwJ,

Thank you again for your thoughtful and encouraging feedback on our work. We greatly appreciate the time and attention you have devoted to reviewing our submission.

As the discussion period draws to a close, we remain happy to provide any additional clarification and would welcome any further feedback you may have.

Best regards,

The Authors

Reviewer LFjROpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
4/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper presents HuatuoGPT-5, a medical vision-language model trained through continued large-scale multimodal pre-training followed by reinforcement learning. The authors construct PubMedVision-Plus, a 60M image-caption corpus extracted from public PubMed papers, and PubMedVision-Plus-Core, a 12M filtered subset selected through multi-stage medical-visual, caption-quality, image-caption consistency, and image-quality filtering. They then synthesize PubMedVision-RL from the caption-grounded pre-training data, using both multiple-choice verifiable rewards and open-ended rubric rewards. The main empirical claim is that, after medical multimodal pre-training, RL elicits medical visual capabilities more effectively than SFT under the authors' setup. Across several medical VLM benchmarks, HuatuoGPT-5 substantially improves over Qwen3-VL backbones and outperforms similarly sized open-source and medical VLM baselines, while narrowing the gap to leading proprietary models.

Strengths and weaknesses

The paper addresses an important and timely problem: open medical VLMs are limited both by the scale of available medical image-text data and by the post-training method used to elicit domain knowledge. The proposed recipe is simple and compelling: scale medical multimodal pre-training using a large PubMed-derived corpus, then use RL over caption-derived verifiable and rubric rewards to activate the learned medical visual knowledge. The dataset scale is a meaningful contribution, and the paper provides substantial appendix detail about data filtering, prompt construction, rubric validation, and physician preference evaluation.

The empirical results are strong. In Table 2, pre-training plus RL improves Qwen3-VL-8B-Instruct by +9.9 average points and Qwen3-VL-32B-Instruct by +10.1 average points across eight medical multimodal benchmarks. The ablations are useful: RL alone gives smaller gains, while pre-training plus SFT gives much smaller gains and even degrades the 32B model average. This supports the paper's claim that domain pre-training and RL are complementary. The paper also evaluates open-ended response quality through MedMM-ExpertRubric and a physician preference study, which is important because medical VLM usefulness is not captured by multiple-choice accuracy alone.

The main weakness is that the strongest causal claim, that RL is better than SFT for eliciting pre-trained medical visual knowledge, is not fully isolated. The SFT baseline uses answers generated by Qwen3-VL-32B-Instruct on the same prompts used for RL. This controls prompt set and data volume, but the comparison may still be confounded by teacher quality and target-answer quality. A much stronger teacher such as Gemini-3-Pro or GPT-5.4 might produce better SFT targets and narrow the gap. Without such an ablation, the evidence supports "this specific RL setup is better than this specific SFT setup" more strongly than it supports "RL generally elicits pre-trained medical visual knowledge better than SFT".

Another weakness is reproducibility and cost. GPT-5.4 is used for seed labels, question generation, validation, and rubric generation; GPT-4.1 is used for rubric judging and to generate 1M labels for a learned reward scorer. The paper appropriately trains a smaller VLM scorer because online GPT-4.1 reward evaluation would be expensive, but it does not report the number of GPT-4.1/GPT-5.4 calls, cost, wall-clock overhead, or detailed validation of the learned scorer beyond 91.5% agreement with GPT-4.1. Since the data and reward pipeline is central to the contribution, these details matter.

The dataset construction pipeline is promising but would benefit from more quantitative validation. The appendix explains the VLM-based quality checks and task-specific classifier heads, but I did not find a physician-reviewed gold-standard subset for PubMedVision-Plus-Core itself, nor precision/recall or modality-specific quality estimates for filtering. Because the dataset is a core contribution, a small human-reviewed quality audit would substantially strengthen the paper.

Finally, the evaluation is strong for medical VQA and PubMed-style figure understanding, but the paper would be more convincing with a small clinical report-style transfer evaluation. The authors acknowledge that PubMed figures differ from real clinical workflows. A quick evaluation on a chest X-ray report generation or clinical radiology task, for example using MIMIC-CXR, IU-Xray, CheXpert Plus, ReXGradient, or ReXVQA if feasible, would help test whether the gains transfer beyond PubMed figure QA. Please have a look at the leaderboards at https://rexrank.ai/ for more details.


Strengths

The scale of PubMedVision-Plus and PubMedVision-Plus-Core is substantial, and the paper gives a relatively transparent filtering pipeline with useful prompts and examples in the appendix.

The pre-training plus RL recipe is simple and well motivated. Table 2 and Figure 1 provide coherent evidence that pre-training raises the ceiling for medical visual capability and that RL elicits more of that capability than the reported SFT baseline.

The paper evaluates both closed-form benchmark accuracy and open-ended medical answer quality, including physician-filtered rubrics and physician preference judgments.

The authors take some care with contamination and general-capability preservation: they filter PMC-VQA by PMCID, mix general-domain tokens during pre-training, mix RubricHub examples during RL, and report general capability results in Table 3.


Weaknesses

The SFT baseline is not strong enough to fully support a broad conclusion that SFT generally fails to elicit pre-trained medical visual knowledge. A stronger-teacher SFT baseline is needed.

The paper lacks statistical uncertainty for the main benchmark results. Even if repeated training runs are too expensive, bootstrap confidence intervals over evaluation examples should be feasible.

The learned reward scorer is not sufficiently characterized. Reporting only 91.5% agreement with GPT-4.1 leaves open questions about calibration, clinically important failure modes, positive vs. negative rubric items, and modality-specific reliability.

The dataset filtering pipeline lacks a clear human gold-standard validation set for PubMedVision-Plus-Core. The appendix describes how filters are trained, but not enough quantitative evidence that the retained 12M pairs meet the intended quality standard across modalities.

Some implementation details are underexplained in the main paper, including sequence packing and masking during pre-training, the meaning of "seed data" and "task-specific heads", and the naming relationship between HuatuoGPT-Vision-7B and the proposed HuatuoGPT-5 models (why do they share the same prefix?).

The manuscript has minor presentation issues, including typographical errors in Figure 2 and missing or non-local citations for some Table 2 baselines.

Questions
  1. Can the authors provide a stronger SFT baseline using a more capable teacher, such as Gemini-3-Pro or GPT-5.4, on the same prompt set? This would help distinguish "RL is better than SFT" from "RL is better than SFT with Qwen3-VL-32B-generated targets." An 8B-scale experiment would already be informative.

  2. Can the authors report confidence intervals for the main benchmark results, for example via bootstrap resampling over evaluation examples? This would be much cheaper than repeated full training runs and would clarify whether the reported gaps and rankings are statistically robust.

  3. Can the authors provide more validation of the learned rubric reward scorer, beyond 91.5% agreement with GPT-4.1? Breakdowns by modality, positive vs. negative rubrics, difficult cases, and clinically significant errors would help establish whether the scorer is reliable enough for RL.

  4. Can the authors provide dataset-level quality metrics for PubMedVision-Plus-Core, ideally using a small human- or physician-reviewed gold-standard subset? Precision/recall of filtering, modality-specific quality, and examples of false positives/false negatives would strengthen the dataset contribution.

  5. Can the authors add a quick clinical report-style or non-PubMed transfer evaluation, if feasible? For example, a small evaluation on MIMIC-CXR, IU-Xray, CheXpert Plus, ReXGradient, or ReXVQA would test whether the gains transfer beyond PubMed-style figure QA. See https://rexrank.ai/

  6. Can the authors clarify the compute/cost of the proprietary-model-dependent pipeline, including approximate numbers of GPT-5.4 and GPT-4.1 calls, label-generation cost, and whether reward scoring affects RL wall-clock time?

  7. Can the authors clarify the pre-training choice of packing multiple image-caption samples into a single length-4096 sequence, including whether attention is masked across packed examples, where loss is applied, and whether this follows a standard prior recipe?

Criteria that could increase my score:

My score would increase with a stronger-teacher SFT baseline, bootstrap confidence intervals, clearer validation of the reward scorer, a human-reviewed dataset quality audit, and a concrete release/licensing plan for the datasets, code, and model checkpoints.

Criteria that could decrease my score:

My score would decrease if stronger SFT baselines substantially close the gap, if the dataset cannot be released or licensed in a usable way, if the learned reward scorer is unreliable on clinically important cases, or if dataset-quality validation reveals substantial filtering noise.

Limitations

The authors discuss several important limitations, including English PubMed coverage, mismatch between PubMed figures and real clinical workflows, reliance on GPT-4.1 for scalable rubric scoring, need for larger physician studies, and the requirement for prospective validation before clinical use. I would like them to expand the limitations around SFT baseline strength, reward-model failure modes, dataset filtering bias, dataset licensing/reuse, and the absence of clinical report-style evaluation, unless these points are addressed during the rebuttal.

Final justification

After reading the rebuttal, I think the concerns have been addressed. All the questions and weaknesses where well address and I paid special attention to the one stating that SFT was not as good as RL, but the teacher used was not strong enough. The additional experiments with stronger teachers (Gemini and GPT) show better evidence than the original experiments. The authors also clarify what they will release, and introduce evaluation metrics for report generation.

Formatting concerns

Minor presentation issues: Figure 2 contains several typos, including "Dection", "informatveness", and "Quility". Table 2 would be easier to interpret if all baseline model entries had local citations or a caption note mapping each model family to references.

4 comments
Authors · CommentOpenReview ↗

Rebuttal by Authors (Part 1)

We sincerely thank the reviewer for the thorough reading and constructive suggestions, which have significantly strengthened our work. We address each point below.

Q1 & W1. The SFT baseline may be limited by teacher quality.

We agree that the original comparison controlled prompt set and data volume, but not teacher quality. We added two stronger-teacher SFT baselines (GPT-5.4-high, Gemini-3-Pro) on the same 85K prompts and pre-trained Qwen3-VL-8B:

8B model / post-training route GMAI MPro MedXQA OMVQA PMC Path SLAKE RAD Avg.
Qwen3-VL-8B-Instruct 51.4 52.6 27.9 74.0 53.1 65.2 73.4 71.0 58.6
Pre-training + SFT (Qwen3-VL-32B teacher) 52.8 46.3 26.4 70.2 60.6 70.2 77.4 73.6 59.7
Pre-training + SFT (Gemini-3-Pro teacher) 51.6 46.8 27.6 71.4 60.9 71.8 77.8 72.0 60.0
Pre-training + SFT (GPT-5.4-high teacher) 55.6 45.6 27.8 73.1 61.3 69.2 79.4 74.7 60.8
Pre-training + RL (ours) 63.2 56.1 34.2 84.5 69.2 74.0 84.6 82.3 68.5

Key observations:

  • Stronger teachers improve SFT only modestly, with Gemini-3-Pro even performing comparably to Qwen3-VL-32B.

  • RL still outperforms the best stronger-teacher SFT by +7.7 points on average. Notably, unlike SFT, RL does not imitate proprietary-model outputs, thus mitigating the risk of external-knowledge contamination.

  • We will revise the conclusion to: under matched prompts and data budgets, RL elicits more pre-trained medical visual capability than imitation in our setting, even with frontier teachers. We will avoid claiming SFT is universally inferior.

Q2 & W2. Statistical uncertainty.

Thank you for this suggestion. We added 95% confidence intervals via 10,000 example-level bootstrap resamples, stratified by benchmark. The paired gains of HuatuoGPT-5 over the 8B and 32B backbones are +9.9 [8.8, 11.0] and +10.1 [9.0, 11.2], respectively. Key benchmark-level CIs:

Model OMVQA (95% CI) GMAI (95% CI) 8-benchmark Avg. (95% CI)
Qwen3-VL-8B-Instruct 74.0 [72.9, 75.1] 51.4 [50.1, 52.7] 58.6 [57.2, 60.0]
HuatuoGPT-5-8B 84.5 [83.6, 85.4] 63.2 [62.0, 64.5] 68.5 [67.2, 69.8]
Qwen3-VL-32B-Instruct 80.8 [79.8, 81.8] 57.0 [55.7, 58.3] 63.9 [62.5, 65.2]
HuatuoGPT-5-32B 88.4 [87.6, 89.2] 65.8 [64.6, 67.1] 74.0 [72.8, 75.3]

The narrow intervals reflect large test-set sizes. We will note that bootstrap CI does not capture training-run variability.

Q3 & W3. More validation of the learned rubric scorer.

Thank you. The original 91.5% reflects agreement between the 8B training scorer and GPT-4.1 on held-out GPT-4.1 labels, not human agreement. We therefore conducted human validation on 300 rubric decisions (image, question, response, rubric) sampled from held-out MedMM-ExpertRubric cases, and additionally annotated them with an 8B scorer. Two physicians each labeled 180 decisions (60 overlapping) with overlap agreement was 88.3% agreement (Cohen's κ=0.77\kappa=0.77). Against the resolved physician labels:

Metric 8B Scorer (Training) GPT-4.1 Judge (Eval)
Agreement 88.7% 90.3%
F1 0.875 0.892
Cohen's κ\kappa 0.751 0.783
Positive F1 0.838 0.856
Negative F1 0.913 0.927

The 8B scorer aligns well with physicians (88.7% agreement, κ=0.751\kappa=0.751), though GPT-4.1 remains more accurate. Crucially, the 8B scorer is used only during RL training to reduce cost, and all final MedMM-ExpertRubric results are evaluated by GPT-4.1. The substantial gains under independent GPT-4.1 evaluation support its practical utility.

Authors · CommentOpenReview ↗

Rebuttal by Authors (Part 2)

Q4 & W4. Human validation of PubMedVision-Plus-Core filtering.

Thank you. This makes the dataset contribution measurable.

We uniformly sampled 500 pairs from the raw PubMedVision-Plus corpus prior to any filtering, forming a gold-standard set. Two physicians independently annotated this set (300 pairs each, with 100 overlapping), blinded to filter outputs and following consistent guidelines. Inter-rater agreement on the overlap was 85% (Cohen's κ=0.58\kappa=0.58), with disagreements resolved via discussion. The gold set contained 115/500 (23.0%) valid pairs. Cumulative filter performance on this set:

Cumulative filtering stage Retention ratio Precision Recall F1
Raw PubMedVision-Plus 100.0% 23.0% 100.0% 37.4%
w/ Medical-visual content (Embedding) 31.2% 71.2% 96.5% 81.9%
w/ Medical-visual content (Embedding) + Caption quality (LLM) 23.6% 86.4% 88.7% 87.6%
w/ Medical-visual content (Embedding) + Caption quality (LLM) + Pair-consistency & image quality (VLM) 20.8% 93.3% 84.3% 88.6%

Observations. The embedding filter removes non-medical figures, while the LLM and VLM stages refine caption quality, pair consistency, and image quality. On the gold-standard set, the three-stage pipeline improves precision from 23.0% to 93.3% and F1 from 37.4% to 88.6%, with a recall of 84.3%. The progressive improvements underscore the complementary value of each filtering stage. Full details will be provided in the revision.

Q5. Clinical report-style or non-PubMed transfer evaluation.

Following this suggestion, we add zero-shot report generation on MIMIC-CXR, IU-Xray, and CheXpert Plus. All models use the same prompt and deterministic decoding. We report CheXbert and RadGraph F1.

8B model MIMIC-CXR IU-Xray CheXpert Plus
Qwen3-VL-8B 35.0 / 12.9 31.7 / 14.1 35.9 / 13.0
Pre-training + SFT 39.9 / 13.6 22.9 / 15.5 38.7 / 13.8
HuatuoGPT-5-8B 44.1 / 16.2 38.6 / 21.5 44.4 / 16.1

Results are CheXbert micro-F1 / partial RadGraph F1

Observations. Pre-training + RL shows consistent gains over the base model (Qwen3-VL-8B-Instruct) across all three datasets, suggesting positive transfer from PubMed-style QA to clinical report generation. Nevertheless, the gap between PubMed-style data and real-world clinical settings suggest these results are promising but far from clinically deployable.

Q6. Proprietary-model cost and reward-scoring overhead.

Thank you for raising this. We now report both API cost and wall-clock impact.

1. API cost

Based on sampled API token usage, we estimate the following proprietary-model costs:

Stage Requests / labels Model Estimated unit cost Estimated cost (USD)
PubMedVision-Plus filter labeling 80K GPT-5.4 ~$0.0051 / request ~$408
PubMedVision-RL construction 550K GPT-5.4 ~$0.0150 / request ~$8.25K
Reward-scorer labeling 1M GPT-4.1 ~$0.00544 / label ~$5.44K
MedMM-ExpertRubric evaluation 250K GPT-4.1 ~$0.00544 / label ~$1.36K
Total 1.88M -- -- ~$15.46K

Why we built a local scorer. Using GPT-4.1 as the online reward model during RL would require ~6.76M rubric judgments (200 steps × 8 rollouts × 33 rubrics × 128 prompts), costing ~$36.8K in scoring alone per RL run. This motivates our 8B local scorer, which we will release to reduce reproduction costs.

2. Wall-clock overhead of reward scoring

Our 8B scorer uses tensor parallelism (TP=4) to share inference GPUs and reduce memory burden. Reward scoring is synchronized with rollout processing to maximize GPU utilization. The scorer is also designed to directly predict decisions without explanations and to score all rubrics in a pass, minimizing computational overhead. Per-iteration times:

Setting Average time per rollout iteration
Rollout only 108.8 s
Rollout + rubric scoring 117.6 s

Observations. The local scorer adds ~8% overhead while avoiding proprietary API calls during training, a trade-off we find acceptable for making medical RL more accessible.

Authors · CommentOpenReview ↗

Rebuttal by Authors (Part 3)

Q7 & W5. Packing, masking, terminology, and naming.

Thanks for raising these. We clarify below.

  • Packing and masking: Pairs are concatenated to length 4096 with <end-of-text> boundary tokens. We use standard causal attention without modification, relying on the boundary token to signal sample boundaries to the model. Loss is applied only to caption tokens. This design offers three benefits:

    1. Higher throughput: Fixed 4096-length sequences enable direct batching and maximize GPU utilization.
    2. Minimal padding waste: Eliminates padding overhead from variable lengths.
    3. Unified length handling: Supports long examples while packing shorter ones for efficient mixed-length training.
  • Filtering terminology: "Seed data" refers to 20K GPT-5.4 binary labels per filtering task. Each compact classifier uses the final [EOS] representation (with mean pooling applied for all-MiniLM-L12-v2) fed into a task-specific binary head (an MLP layer) for corpus-scale inference.

  • Model naming: "HuatuoGPT-5" reflects our open-source commitment. "Vision" dropped because we adapt from an instruction-tuned VLM (not a base model), so "Vision" would mislead. We are happy to rename if the reviewer prefers.

  • Presentation: We corrected "Dection," "informatveness," and "Quility" in Figure 2 and will add citations for all Table 2 baselines.

Release and licensing plan.

We will release the following assets (estimated timeline: August–September 2026):

Asset Release content
PubMedVision-Plus-Core 12M image-caption pairs and metadata
PubMedVision-RL 70K questions with labels/rubrics and metadata
PubMedVision-Plus A filter-validation subset (tentative)
MedMM-ExpertRubric 500 questions with physician-verified rubrics and evaluation scripts
Models HuatuoGPT-5-8B/32B, pre-trained checkpoints, quality filtering models, and the 8B rubric scorer
Tooling Training/evaluation code, prompts, and configs

Licenses: Code and model components will use Apache-2.0 where permitted by base-model terms. RL data and benchmark annotations will use CC BY 4.0. For PubMedVision-Plus-Core, we will carefully package the data to make direct download and reconstruction as convenient as possible, while preserving source-image licenses.

We hope these additions and planned releases make our pipeline reproducible and useful for the community.

Authors · CommentOpenReview ↗

Thank You and Follow-up

Dear Reviewer LFjR,

Thank you again for your insightful and constructive review. We have carefully addressed your comments in our responses below and hope that our clarifications have resolved your concerns.

As the discussion period nears its end, we would welcome any further questions or remaining concerns. We would be happy to provide additional clarification as needed.

We greatly appreciate the time and insights you have devoted to our work and welcome any further feedback you may have.

Best regards,

The Authors

Reviewer 7oXiOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
4/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes HuatuoGPT-5, a medical VLM built through large-scale medical multimodal pre-training followed by reinforcement learning. The authors first construct PubMedVision-Plus, a large PubMed-derived medical image-caption corpus containing around 60M image-caption pairs, and further filter it into a 12M high-quality subset, PubMedVision-Plus-Core. The model is then continued-pretrained on this medical image-text data to inject domain-specific visual knowledge. To elicit this knowledge, the authors synthesize PubMedVision-RL from the same pre-training corpus, including closed-ended multiple-choice instances with verifiable rewards and open-ended questions with rubric-based rewards. HuatuoGPT-5 is trained from Qwen3-VL backbones at 8B and 32B scales, and the paper reports substantial gains over the base models and over SFT-based post-training on multiple medical VLM benchmarks, expert-rubric evaluation, and a physician preference study.

Strengths and weaknesses

Strengths

  1. The construction of PubMedVision-Plus and PubMedVision-Plus-Core is valuable for the community.
  2. The empirical evaluation is relatively broad. The authors compare against proprietary, open-source, and medical VLMs; evaluate both 8B and 32B models; include general-domain capability preservation; and add expert-rubric and physician preference evaluations beyond standard accuracy benchmarks.

Weakness

  1. The data contribution is central, but reproducibility is still uncertain. The checklist says full data, code, and models will be released, but also marks open access to data and code as “No” at submission time. For a paper whose main contribution includes a large new dataset, RL dataset, benchmark, and model family, the lack of full release details weakens verifiability.
  2. The open-ended evaluation still depends substantially on model-based judging. MedMM-ExpertRubric uses physician-verified rubrics, but scalable scoring is performed by GPT-4.1 or a trained small VLM scorer. The physician preference study is valuable, but it has only 100 questions and two attending physicians. Larger human validation, confidence intervals, inter-rater agreement details, and failure-case analysis would strengthen the reliability of the conclusions.
  3. The SFT + RL post-training recipe is widely used in general LLM/VLM post-training, the methodology novelty is limited.
Questions
  1. What exactly will be released, and under what license or access conditions? Please clarify whether PubMedVision-Plus, PubMedVision-Plus-Core, PubMedVision-RL, MedMM-ExpertRubric, code, model checkpoints, filtering classifiers, and scoring models will be released. Since the paper’s impact depends heavily on the new assets, a clear release plan and license/terms-of-use discussion are important.

  2. How reliable is the rubric-based evaluation? Please provide more details on GPT-4.1 judge reliability, the trained scorer’s calibration, human agreement with the judge, confidence intervals, and failure cases. For the physician preference study, please report inter-rater agreement, statistical uncertainty, and whether the 100 questions cover diverse modalities and anatomical regions.

Limitations

yes

Final justification

The rebuttal has substantially addressed my main concerns. Please see more details in the official comments I added after the rebuttal response.

Formatting concerns

N/A

5 comments
Authors · CommentOpenReview ↗

Rebuttal by Authors (Part 1)

We sincerely thank the reviewer for recognizing the value of our data contribution and the breadth of our evaluation. We especially appreciate the concrete suggestions on release, rubric reliability, and positioning. We address them below.

W1 & Q1. What exactly will be released, and under what license/access conditions?

We regret the confusing checklist response. The "No" was intended only to reflect the submission-time non-public status of anonymous artifacts, but we understand this was misleading. We will correct this and release:

Asset Release content
PubMedVision-Plus-Core 12M image-caption pairs and metadata
PubMedVision-RL 70K questions with labels/rubrics and metadata
PubMedVision-Plus A filter-validation subset (tentative)
MedMM-ExpertRubric 500 questions with physician-verified rubrics and evaluation scripts
Models HuatuoGPT-5-8B/32B, pre-trained checkpoints, quality filtering models, and the 8B rubric scorer
Tooling Training/evaluation code, prompts, and configs

Code and model components will use Apache-2.0 where permitted by base-model terms. RL data and benchmark annotations will use CC BY 4.0. For PubMedVision-Plus-Core, we will carefully package the data to make direct download and reconstruction as convenient as possible, while preserving source-image licenses.

Authors · CommentOpenReview ↗

Rebuttal by Authors (Part 2)

W2 & Q2. Reliability of rubric-based evaluation and the physician study.

Thank you for suggesting additional analyses to strengthen the reliability of our open-ended evaluation. Since open-ended medical multimodal evaluation remains scarce and challenging, we propose two complementary strategies: a rubric-based evaluation for low-cost, fine-grained assessment, and a physician preference study for expert-aligned judgment. Following the reviewer's suggestions, we provide the additional details below.

1. For the rubric-based evaluation

(1) Human validation of model judges. To assess rubric-scoring reliability, we sampled 300 (image, question, response, rubric, GPT-4.1 decisions) from held-out MedMM-ExpertRubric cases and additionally annotated them with an 8B scorer. Two physicians independently judged rubric criterion satisfaction across 180 decisions each, with 60 overlapping for agreement measurement. They achieved 88.3% agreement (Cohen's κ=0.77\kappa=0.77), resolving disagreements by discussion.

Results against human labels:

Metric 8B Scorer (Training) GPT-4.1 Judge (Eval)
Agreement 88.7% 90.3%
F1 0.875 0.892
Cohen's κ\kappa 0.751 0.783
Positive F1 0.838 0.856
Negative F1 0.913 0.927

Against the resolved human labels, GPT-4.1 achieved 90.3% agreement and the 8B scorer achieved 88.7%. The 8B scorer is used only during RL training to reduce cost, and all final MedMM-ExpertRubric results are evaluated by GPT-4.1.

(2) Confidence intervals. We quantify evaluation uncertainty via 10,000 paired bootstrap resamples (500 questions each, with replacement), using the same sampled indices across models to preserve question-level difficulty.

Model MedMM-ExpertRubric 95% CI
Qwen3-VL-8B-Instruct 22.1 [19.9, 24.2]
HuatuoGPT-5-8B 35.7 [33.1, 38.4]
Qwen3-VL-32B-Instruct 30.9 [28.4, 33.4]
HuatuoGPT-5-32B 40.8 [38.1, 43.4]

HuatuoGPT-5 outperforms its backbone by +13.6 points (8B) and +9.9 points (32B), with non-overlapping CIs. These intervals reflect benchmark sampling uncertainty, not variation across training runs.

(3) Failure cases. We inspected all cases where GPT-4.1 disagreed with expert-annotated references. GPT-4.1 made 29/300 (9.7%) errors. These errors clustered into six systematic failure modes, summarized below.

Error type Case Expert / GPT-4.1 Rubric demand Why GPT-4.1 failed
Negation inversion decision_279 (ECG) T / F Negative criterion: absence of low voltage should be flagged as true GPT-4.1 treated omission as false, inverting the logic—it cannot reliably evaluate criteria framed as "fails to mention X."
Literal overfitting decision_141 (nuclear med) T / F Identifies "nuclear medicine scintigraphy images" GPT-4.1 rejected "nuclear medicine images" because "scintigraphy" was not verbatim, failing to recognize clinically synonymous terminology.
Local over-crediting decision_113 (leg wound) F / T Overall healing-stage framing required, not active ulceration GPT-4.1 over-credited a partial mention of "chronic/scarred" and ignored that the response predominantly described active ulceration, missing the required global framing.
Primary/secondary confusion decision_288 (contrast X-ray) F / T "Most important takeaway" is absence of leakage GPT-4.1 credited "no leak" as sufficient even though the response presented it as a secondary finding, while the criterion explicitly demands the primary takeaway.
Conjunctive collapse decision_081 (ECG) F / T Requires both: avoid STEMI AND center on QT prolongation GPT-4.1 marked the criterion true after satisfying only the first condition (avoid STEMI), collapsing the conjunctive (AND) requirement into disjunctive (OR).
Paraphrase under-recognition decision_052 (post-op wound) T / F "Left open rather than primarily closed" GPT-4.1 demanded exact contrastive phrasing and under-credited the clinically equivalent description "large raw/open defect awaiting coverage."

These failures consistently arise where rubrics demand complex semantic reasoning beyond keyword matching, such as negation, global framing, priority weighting, conjunctive logic, or clinical paraphrasing. We keep GPT-4.1 as the official judge for consistency, but report these limitations to justify subsequent blinded physician adjudication.

Authors · CommentOpenReview ↗

Rebuttal by Authors (Part 3)

2. For the physician preference study

(1) Reliability and uncertainty of physician preference judgments. Inter-rater agreement is reported in Appendix G, but we agree it should be more prominent. Each model pair has 100 unique questions and 120 total physician judgments. Across six pairwise comparisons, overlap exact agreement is 71.8% and mean Cohen's κ=0.537\kappa=0.537. Following the reviewer's suggestion, We add uncertainty estimates below:

HuatuoGPT-5-32B vs. Win / Tie / Loss (%) Win rate excluding ties (95% CI)
Qwen3-VL-32B-Instruct 55 / 18 / 27 67.1% [56.4, 76.3]
Lingshu-32B 65 / 14 / 21 75.6% [65.5, 83.5]
GPT-5.4-mini 41 / 21 / 38 51.9% [41.0, 62.6]

(2) The 100 questions cover diverse modalities and anatomy. Their distributions are summarized below (sorted by count, with totals):

Modality Coverage

Modality MRI Others CT Specialized Radiology Ultrasound Digital Photo. X-ray Microscopy/Path. Nuclear Med. Endoscopy Ophthalmologic Imaging Total
Count 15 14 13 13 10 10 8 6 4 4 3 100

Anatomical Coverage

Anatomy Extremities Chest Head/Neck/Oral GI tract Brain Skin Abdomen/Pelvis Others Spine/Bone Cell Total
Count 22 20 15 10 9 8 5 5 4 2 100

We will move the reliability and uncertainty results closer to the main evaluation, and add the complete per-question modality/anatomy audit to the supplement.

W3. Methodology novelty is limited.

We agree that the SFT/RL pipeline is not a new algorithm, and we thank the reviewer for acknowledging our data and evaluation contributions.

Our contribution, rather, centers on identifying two distinct bottlenecks in medical VLMs: insufficient visual knowledge and ineffective knowledge activation, and propose a tailored paradigm to address them.

Concretely, starting from an instruction-tuned VLM, we adopt continued Pre-training → RL, skipping SFT stage. This differs from the common Pre-training → SFT recipe and offers three benefits:

  1. Efficient enhancement. It improves medical capability while preserving general performance, avoiding the heavy cost of restarting from a base VLM.
  2. Less data dependence. Skipping SFT reduces sensitivity to teacher-answer quality and style.
  3. A closed loop. The same corpus plays two roles: first as pre-training data for knowledge injection, then as the source of verifiable rubric rewards for activation.

We will reframe the novelty as a data-and-training paradigm for medical VLMs, not as an algorithmic contribution. We hope this clarifies our intent.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.