Temporal Island Sparse Autoencoders for Interpreting Clinical Time-Series Models
Muhan Yeo, Bong Gyun Kang, HyunGi Kim, Sungroh Yoon
NeurIPS 2026
TL;DR. A sparse autoencoder with learned temporal Gaussian islands and sparse variable composition that decomposes clinical time-series models into a dictionary of interpretable concepts.
Abstract. Deep learning models for electronic health records achieve strong predictive performance but provide little insight into what clinical concepts they represent internally. Post-hoc attribution methods produce per-cell importance scores that lack temporal coherence, cross-variable structure, and reusability across patients. We introduce the Temporal Island Sparse Autoencoder (TI-SAE), which learns a backbone-specific, patient-shared clinical concept dictionary from a frozen predictive model’s representations. Each dictionary entry (latent) is defined by learned temporal Gaussian islands—specifying when the concept is active—and a sparse variable-composition vector—specifying which variables are involved. A decoupled selector then identifies which dictionary entries drive each patient’s prediction, separating representation learning from attribution. We evaluate TI-SAE across five backbone architectures spanning different representation strategies on MIMIC-III and MIMIC-IV (three prediction tasks each). TI-SAE produces structured clinical concepts that go beyond transient attribution heatmaps while achieving strong performance on standard faithfulness benchmarks.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:46 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper introduces Temporal Island Sparse Autoencoders, a post-hoc method that decomposes hidden representations of frozen clinical time-series models into reusable temporal concepts. Each concept is represented by sparse clinical variables and Gaussian temporal windows. A prediction-aware selector identifies concepts sufficient to reproduce a model prediction. Experiments cover five backbones, MIMIC-III and MIMIC-IV, several prediction tasks, faithfulness analyses, reproducibility checks, and clinician evaluation.
The paper addresses a significant interpretability problem using a representation more temporally coherent than cell-level attribution maps. Reviewer oxGc considers the formulation original and technically sound. Reviewer 8yxd highlights the practical advantage that the method can be applied to frozen models without retraining. The evaluation is broad for post-hoc clinical interpretability and includes multiple architectures, datasets, tasks, ablations, and human assessment.
The stability and clinical meaning of learned dictionaries are not fully established across seeds, patients, and datasets. Reviewer ShNf notes that some semantic labels are generated post hoc using an LLM and that clinician inter-rater agreement is low. Reviewer 8yxd argues that the prediction-aware selector may find any sufficient concept subset rather than recover the original model's actual reasoning; ablations suggest the selector may drive much of the faithfulness gain. Symmetric Gaussian windows may be too restrictive for abrupt, persistent, decaying, recurrent, or asymmetric clinical patterns. Cross-dataset claims are weakened by the relationship and possible overlap between MIMIC-III and MIMIC-IV.
The recommendation could change if the author response provides the following decision-relevant evidence:
- Report cross-seed and cross-patient stability of dictionary entries and selected concepts.
- Isolate the contribution of the temporal dictionary from the prediction-aware selector. To assess whether the faithfulness gains come from the temporal dictionary rather than the selector alone, provide an ablation that applies the same prediction-aware selector to raw hidden states and to a standard SAE without temporal islands, so the effect of the dictionary can be isolated from the selector.
- Clarify how much clinical meaning can be supported given the low inter-rater agreement and post hoc LLM labeling. Provide results without the LLM-generated labels to separate the quality of the underlying attribution from the fluency of the summarization.
- Justify the restrictiveness of symmetric Gaussian temporal windows. Clinical patterns often exhibit asymmetric temporal dynamics (e.g., sudden onset followed by slow resolution, or irregular recurrences). Compare the current formulation against asymmetric, decaying, or more flexible temporal functions, or demonstrate empirically why symmetric windows do not distort these physiological events.
- Address potential patient overlap and dataset confounding between MIMIC-III and MIMIC-IV, and provide a strictly disjoint out-of-distribution evaluation.
- Table 2 aggregates results across three tasks and two datasets, which may hide failure modes; the authors should provide task-by-task and dataset-by-dataset results.
- SOFA is a coarse and incomplete benchmark for general clinical interpretability because it focuses on organ-failure physiology and may miss subtle or early-stage concepts. Comparisons against a broader ICU severity score such as APACHE II, SAPS II, or OASIS would help show whether the learned concepts align with more general clinical severity.
- Explain the adaptations of TimeX, TimeX++, and ExtremalMask clearly, and justify their exclusion from the main comparison with enough detail that readers can assess whether the failure reflects the methods or the adaptation choices.
Final justification
This paper introduces Temporal Island Sparse Autoencoders (TI-SAE), a post-hoc interpretability method designed to decompose the hidden representations of frozen clinical time-series models into reusable temporal concepts. These concepts are defined by sparse clinical variables and temporal Gaussian islands. During the initial review phase, the reviewers praised the method's strong originality and practical value, as it can be applied without retraining the predictive backbones. However, the reviewers and Area Chair raised several critical concerns, notably regarding the restrictiveness of symmetric Gaussian windows, the lack of evaluation on non-MIMIC datasets, the stability of the learned dictionaries, and the potential confounding effect of the prediction-aware selector. The authors provided an exhaustive rebuttal that successfully addressed these concerns, leading all three reviewers to raise or maintain their scores to an "Accept" recommendation.
Read meta-review
Meta-review
The paper introduces Temporal Island Sparse Autoencoders, a post-hoc method that decomposes hidden representations of frozen clinical time-series models into reusable temporal concepts. Each concept is represented by sparse clinical variables and Gaussian temporal windows. A prediction-aware selector identifies concepts sufficient to reproduce a model prediction. Experiments cover five backbones, MIMIC-III and MIMIC-IV, several prediction tasks, faithfulness analyses, reproducibility checks, and clinician evaluation.
The paper addresses a significant interpretability problem using a representation more temporally coherent than cell-level attribution maps. Reviewer oxGc considers the formulation original and technically sound. Reviewer 8yxd highlights the practical advantage that the method can be applied to frozen models without retraining. The evaluation is broad for post-hoc clinical interpretability and includes multiple architectures, datasets, tasks, ablations, and human assessment.
The stability and clinical meaning of learned dictionaries are not fully established across seeds, patients, and datasets. Reviewer ShNf notes that some semantic labels are generated post hoc using an LLM and that clinician inter-rater agreement is low. Reviewer 8yxd argues that the prediction-aware selector may find any sufficient concept subset rather than recover the original model's actual reasoning; ablations suggest the selector may drive much of the faithfulness gain. Symmetric Gaussian windows may be too restrictive for abrupt, persistent, decaying, recurrent, or asymmetric clinical patterns. Cross-dataset claims are weakened by the relationship and possible overlap between MIMIC-III and MIMIC-IV.
The recommendation could change if the author response provides the following decision-relevant evidence:
- Report cross-seed and cross-patient stability of dictionary entries and selected concepts.
- Isolate the contribution of the temporal dictionary from the prediction-aware selector. To assess whether the faithfulness gains come from the temporal dictionary rather than the selector alone, provide an ablation that applies the same prediction-aware selector to raw hidden states and to a standard SAE without temporal islands, so the effect of the dictionary can be isolated from the selector.
- Clarify how much clinical meaning can be supported given the low inter-rater agreement and post hoc LLM labeling. Provide results without the LLM-generated labels to separate the quality of the underlying attribution from the fluency of the summarization.
- Justify the restrictiveness of symmetric Gaussian temporal windows. Clinical patterns often exhibit asymmetric temporal dynamics (e.g., sudden onset followed by slow resolution, or irregular recurrences). Compare the current formulation against asymmetric, decaying, or more flexible temporal functions, or demonstrate empirically why symmetric windows do not distort these physiological events.
- Address potential patient overlap and dataset confounding between MIMIC-III and MIMIC-IV, and provide a strictly disjoint out-of-distribution evaluation.
- Table 2 aggregates results across three tasks and two datasets, which may hide failure modes; the authors should provide task-by-task and dataset-by-dataset results.
- SOFA is a coarse and incomplete benchmark for general clinical interpretability because it focuses on organ-failure physiology and may miss subtle or early-stage concepts. Comparisons against a broader ICU severity score such as APACHE II, SAPS II, or OASIS would help show whether the learned concepts align with more general clinical severity.
- Explain the adaptations of TimeX, TimeX++, and ExtremalMask clearly, and justify their exclusion from the main comparison with enough detail that readers can assess whether the failure reflects the methods or the adaptation choices.
Final justification
This paper introduces Temporal Island Sparse Autoencoders (TI-SAE), a post-hoc interpretability method designed to decompose the hidden representations of frozen clinical time-series models into reusable temporal concepts. These concepts are defined by sparse clinical variables and temporal Gaussian islands. During the initial review phase, the reviewers praised the method's strong originality and practical value, as it can be applied without retraining the predictive backbones. However, the reviewers and Area Chair raised several critical concerns, notably regarding the restrictiveness of symmetric Gaussian windows, the lack of evaluation on non-MIMIC datasets, the stability of the learned dictionaries, and the potential confounding effect of the prediction-aware selector. The authors provided an exhaustive rebuttal that successfully addressed these concerns, leading all three reviewers to raise or maintain their scores to an "Accept" recommendation.
2 comments
Official Comment by Authors [2/2]
5) Patient overlap and a strictly disjoint out-of-distribution evaluation. On a strictly disjoint MIMIC-IV cohort (admissions from 2014 on, entirely after MIMIC-III's 2012 cutoff), removing the overlap does not degrade transfer (prediction AUROC .864, plausibility .756), so the overlap was not inflating the cross-dataset result. Because both MIMIC cohorts share a source hospital, we add an institution-level evaluation on eICU-CRD: the frozen MIMIC-III model transfers (prediction AUROC .803, neighborhood AOPC .158, TI-SAE first among the methods evaluated) and a model trained from scratch on eICU also ranks first. Detail: comments to Reviewers oxGc (Q3) and ShNf (Limitation).
6) Task-by-task and dataset-by-dataset results. We give the full breakdown across all 30 (backbone × task × dataset) cells, all methods, for both faithfulness and plausibility. TI-SAE has the best neighborhood AOPC in 20 of 30 cells and the best plausibility in 9 of 30 (competitive rather than dominant on the latter). Detail: comment to Reviewer ShNf (Q1, W5).
7) SOFA versus a broader severity score. A cell-level plausibility target must assign severity per variable and per time: SOFA is organ-decomposed and validated for serial, repeated-in-time use (Ferreira et al. 2001; Moreno et al. 1999), whereas APACHE II, SAPS II, and OASIS are one-time worst-value-in-24h admission scores without cell-level or temporal resolution. Unlike SOFA, adapting these scores into a per-cell, real-time prior is not a validated ground truth, so we believe plausibility measured against them could neither support the method when agreement is high nor count against it when agreement is low. We therefore retain SOFA as our cell-level plausibility target. Detail: comment to Reviewer ShNf (W7).
8) TimeX, TimeX++, and ExtremalMask TimeX/TimeX++ train an interpretable surrogate with their own encoder, and ExtremalMask trains a per-sample mask plus learned perturbation. We tried several adaptations, including rewriting them from grid to event-space masking, fixing library-level mask handling, driving TimeX/TimeX++'s MaskGenerator from the frozen backbone's features, and running ExtremalMask on the frozen representation with tuned regularization. They were near-random each time (conditional AOPC 0.003–0.020). We cannot attribute this to the methods rather than to our adaptation on sparse event data, so we exclude them out of caution rather than as a defeated baseline, and include mask/perturbation methods that run reliably on the frozen backbone. Details in Appendix B.
We are grateful for the framing, and are happy to provide any further detail that would be useful.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This work introduces TI-SAE, a post-hoc method designed to turn a black-box clinical model into a dictionary of reusable patterns. Rather than explaining predictions through isolated importance scores for individual measurements, TI-SAE learns latent concepts that link groups of clinical variables over specific periods of a patient trajectory.
The method is applied to the hidden representations of a frozen backbone, through a 2-stage process. In the first stage, it learns a shared dictionary in which each concept is defined by a sparse set of variables and one or more Gaussian temporal windows indicating when that concept is active. In the second stage, a prediction-aware selector identifies which concepts are most relevant to an individual patient’s prediction. The selector is trained to choose concepts that allow the frozen prediction head to reproduce the backbone’s original output when retained, while reducing the evidence for that output when those concepts are removed.
Strengths and weaknesses
Strengths
- The idea is novel and potentially very useful . The authors correctly argue that clinicians reason from temporally-related patterns rather than isolated measurements. As such turning the backbone’s hidden representations into reusable clinical concepts, by making clinically meaningful patterns explicit through links between clinical variables over time, produces explanations in a form that is much closer to clinical reasoning than a standard heatmap of independent attribution scores.
- TI-SAE is fully post-hoc and can be applied without modifying or retraining most predictive backbones. This makes it practical to use with existing clinical models and allows the same explanation framework to be tested across architectures that represent clinical events in different ways.
- Strong evaluation setup. The method is tested across five backbones, two versions of MIMIC (III and IV), and three prediction tasks. The authors also include faithfulness and plausibility analyses, clinician assessment, reproducibility checks, ablations, and cross-dataset transfer.
Weaknesses
- The learned prediction selector is likely a confounder for the evaluation of the dictionary. This is because reproducing the backbone’s output does not uniquely identify its internal reasoning. There could be many different subsets of latent islands that give the same or a very similar prediction. The selector could just be finding any subset of latent islands whose information is sufficient for the frozen prediction head to reproduce its original output, not necessarily the subset the backbone itself relied on. If so, improved faithfulness scores would reflect output-matching rather than genuine recovery of the backbone's internal reasoning.
- The ablation results suggest that the prediction-aware selector may be doing most of the work behind the reported faithfulness scores. Replacing it with energy-based or gradient-based selection causes a substantial drop in AOPC, while removing the temporal-island mechanism has very little effect. This makes it unclear whether the improvement comes from the proposed temporal concept representation, or simply from training a selector specifically to find the latent islands that most strongly affect the prediction.
- The choice of Gaussian temporal windows is not sufficiently justified. It assumes that all clinical concepts can be represented by a fixed number of symmetric, contiguous periods of activation, but the paper does not compare this against asymmetric, decaying, persistent, or more flexible alternatives. This may be too restrictive for clinical patterns that appear suddenly, resolve slowly, progress monotonically, or recur irregularly throughout the patient trajectory.
Questions
-
When the Stage-A dictionary is held fixed, how stable are the concepts selected for the same patient across repeated training runs of the prediction-aware selector, over different seeds ?
-
Can the authors more clearly separate how much of the improvement in faithfulness comes from the prediction-aware selector and how much comes from the learned dictionary itself? A matched ablation applying the same selector to alternative representations would help clarify whether the dictionary provides an additional benefit.
-
Why were symmetric Gaussian windows chosen to represent all concept activations, instead of other alternatives?
Limitations
Yes.
Final justification
The rebuttal addresses most of my original concerns, especially on selector stability and the Gaussian-window design. My remaining concern is narrower: the selected concepts are reproducible, but output-matching still does not prove that they recover the backbone’s actual internal reasoning. The new ablations also clarify that temporal islands mainly improve interpretability/plausibility rather than faithfulness itself. Given the additional evidence, I am increasing my score and now recommend acceptance.
Formatting concerns
No
4 comments
Rebuttal
We thank the reviewer for the detailed and constructive feedback, and address each point below.
Q1, W1. Selector-seed stability
We agree that reproducing the backbone's output does not uniquely identify its internal reasoning, and we do not claim to recover a unique subset. The empirical question is whether the selector, given this non-uniqueness, at least converges on a reproducible subset, or whether its selection is unstable across runs. We ran this experiment.
We fixed the Stage-A dictionary and retrained the selector over five seeds (Discrete backbone, MIMIC-III mortality), then measured how consistently it selects the same concepts for the same patient:
| metric (per-patient, across five selector seeds) | value | random null |
|---|---|---|
| selection Jaccard, top-64 | .708 ± .017 | .026 |
| PS-score rank correlation (Spearman) | .870 ± .029 | ~0 |
The selector's importance ranking is highly consistent across seeds (Spearman ρ = .870), and the top-64 selection overlaps at Jaccard .708, far above the random-subset null (.026). Faithfulness is likewise stable (conditional AOPC .151 ± .008; the paper's .149 falls in this range). In addition, zero-ablating concepts in prediction-selector rank order degrades the prediction monotonically and more than random-order removal at every k (largest gap at k=26, Δp .170 vs .099; Appendix G.6, Figure 7a). These results establish that the selector is reproducible under a fixed dictionary and that the selected concepts are functionally important to the prediction (knockout degrades faster than random removal). They do not establish that the subset is unique or that it recovers the backbone's actual reasoning.
Q2, W2. Isolating the dictionary from the selector
We agree this separation is important. The dictionary plays an independent and important role, turning a sufficient set of cells into a decomposable, spatiotemporally grounded concept that is shared across patients, which the selector alone cannot produce. Still, it is important to decompose where the performance gain comes from.
Some of these structural ablations are already reported in Appendix J.3 and Table 35, and here we add the raw-hidden-state condition. The comparison uses matched objectives and selection budgets (Discrete backbone, MIMIC-III mortality):
| representation | AOPC | plausibility |
|---|---|---|
| raw hidden states | .038 | .565 |
| standard SAE | .155 | .568 |
| TI-SAE | .149 | .756 |
Applying the selector to representations without islands requires adapting it (cell-level selection for raw states; global per-latent weighting for the standard SAE), so this comparison is not fully controlled. With that caveat, learned latent representations substantially improve AOPC over raw hidden states (.149/.155 vs .038), consistent with a representation-level contribution beyond prediction-aware selection alone. The specific TI-SAE architecture, however, is not required for this faithfulness gain: as the reviewer notes, removing the temporal islands has little effect on AOPC. The islands instead primarily improve concept plausibility and interpretability, which is the structural information needed to read the dictionary.
Q3, W3. Symmetric Gaussian windows
We acknowledge that our manuscript did not sufficiently emphasize this point. We would first clarify the role of the windows. A Gaussian window does not represent a concept's activation trajectory. It is a temporal support gate that indicates when a concept is active, while the activation strength is carried by the encoder output. The window parameters (center mu and width sigma) are inferred from the data, with mu taken from a soft-attention center over the activation trace and sigma from an EM estimate of its temporal spread. A gaussian window in this study is expected to localize a concept in time rather than imposing a symmetric shape on its activation.
In addition, a concept's mask is also composed from M windows rather than a single one, so it is not limited to one symmetric bump. The effective mask is the sum of the M selected Gaussians clamped to [0,1], which covers different shapes, including persistent plateau, a recurrent mask, and a skewed onset mask. Figure 3 shows several such composed masks. Our ablation over M, which is in appendix J.4, Table 39, also shows the mechanism matters:
| M | AOPC | Plaus. AUROC | Plaus. AUPRC |
|---|---|---|---|
| 1 | .131 | .723 | .346 |
| 2 | .152 | .731 | .341 |
| 4 | .149 | .756 | .386 |
| 8 | .144 | .703 | .357 |
With a single window the concept shows weaker performance, and adding windows improves it up to around M=2 to 4.
Nevertheless, we also tested the primitive directly. We replaced the symmetric Gaussian with a split-normal (skewed) window, with the skew a either learned per island or held fixed, and re-ran the full pipeline over 3 seeds, which showed no meaningful difference:
| island shape | conditional AOPC | SOFA plaus. |
|---|---|---|
| symmetric | .140 ± .006 | .739 ± .013 |
| learned asymmetric | .142 ± .014 | .725 ± .013 |
| fixed asymmetric (a = 0.5) | .141 ± .016 | .715 ± .031 |
When the skew is free the model uses it heavily (mean |a| about 0.34, with 85 to 96% of islands skewed), so asymmetry is available and actively used, yet performance is unchanged. This supports that the symmetric window is not a restrictive choice for these tasks.
Clarity
We thank the reviewer for flagging clarity. We will revise the exposition, in particular the two-stage pipeline and what the prediction-aware selector claims, and surface the key ablations in the main text. We would welcome pointers to any sections that were hardest to follow.
We thank the reviewer again for the thoughtful comments, which have helped us strengthen the paper. The new analyses in this response will be included in the camera-ready.
Response to the meta-review (Area Chair)
The meta-review's decision-relevant points are addressed across the three reviewer responses; Point 8 (baseline exclusion) was not raised by any reviewer, so we answer it here.
TimeX/TimeX++ train an interpretable surrogate with their own encoder, and ExtremalMask trains a per-sample mask plus learned perturbation. We tried several adaptations, including rewriting them from grid to event-space masking, fixing library-level mask handling, driving TimeX/TimeX++'s MaskGenerator from the frozen backbone's features, and running ExtremalMask on the frozen representation with tuned regularization. They were near-random each time (conditional AOPC 0.003–0.020). We cannot attribute this to the methods rather than to our adaptation on sparse event data, so we exclude them out of caution rather than as a defeated baseline, and include mask/perturbation methods that run reliably on the frozen backbone. Details in Appendix B.
We follow up on the symmetric Gaussian window (W3) with some tests of concept-level shape flexibility.
Symmetric Gaussian windows (W3)
We tested the primitive directly in our response: replacing the symmetric window with a split-normal (skewed) window, with the skew learned per island or held fixed, changed neither faithfulness nor plausibility, even though the model used the skew heavily when it was free. Per-window flexibility is available and exercised, but buys nothing. This is because the windows are already diverse at the concept level: a concept's mask is the clamped sum of its M windows, and on the canonical model (Discrete backbone, MIMIC-III mortality) most concepts use more than one.
Windows per selected concept:
| windows per concept | 1 | 2 | 3 | 4 | ≥2 |
|---|---|---|---|---|---|
| share of concepts | 32% | 21% | 23% | 25% | 68% |
The composed mask therefore departs from a single symmetric Gaussian for about two-thirds of concepts. Fitting the best single Gaussian to each realized mask over a free grid of centers and widths:
Best single-Gaussian fit to the realized mask:
| single-Gaussian R² | ≥ 0.99 | 0.95–0.99 | 0.90–0.95 | 0.80–0.90 | < 0.80 |
|---|---|---|---|---|---|
| share of concepts | 30% | 15% | 13% | 13% | 29% |
42% of masks fall below R² 0.90 and 29% below 0.80 (median 0.93): many concepts realize shapes that a single symmetric Gaussian does not reproduce. Since the symmetric shape is only the per-island building block, and the realized window is composed from several islands and gated over an encoder-driven activation, the symmetric choice does not appear to restrict the concept-level temporal pattern in practice.
We thank the reviewer again for the constructive feedback, and welcome any further questions.
I thank the authors for their detailed and exhaustive rebuttal and follow-up comments. The rebuttal addresses most of my original concerns, especially on selector stability and the Gaussian-window design. My remaining concern is narrower: the selected concepts are reproducible, but output-matching still does not prove that they recover the backbone’s actual internal reasoning. The new ablations also clarify that temporal islands mainly improve interpretability/plausibility rather than faithfulness itself. Given the additional evidence, I am increasing my score and now recommend acceptance.
We thank the reviewer for engaging thoroughly throughout the discussion, and for the increased score. We're glad the additional evidence addressed the concerns.
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This work proposes Temporal Island Sparse Autoencoders (TI-SAE) - a post hoc sparse autoencoder for frozen EHR backbones. Each latent has sparse weights and multiple gaussian islands, to give each concept temporal extent and variable composition. This attempts to address the intepretation of clincial time series models in a reusable, temporally coherent manner with multivariable concepts as opposed to per-cell attribution heatmaps. They then use a second prediction aware selector for a patient level prediction to identify which learned islands are most relevant.
Strengths and weaknesses
Strengths: -This problem is well motivated and it's known that clinical time series attribution methods generally produce fragmented heatmaps that are hard to relate to clinical concepts
- the architecture makes sense, sparse variable routing plausibly encourages multivariable concepts, the TIs should impose temporal extent and the separate prediction selector should help to identify/separate patient-specific attribution from dictionary learning
- the representation should end up more structured than ordinary saliency maps (although I'd love to see more and additional quantitative eval of this to supplement qualitative examples)
- the empirical results support the theory (particularly perturbation faithfulness, SOFA-derived plausibility, dictionary reproducibility, clinician ratings, verbalized explanation quality)
Weaknesses:
- The strongest claims around "clinical concepts" aren't fully establisehd. e.g., semantic labels are generated post hoc by an LLM from selected exemplars, then evaluated by clinicians under limited conditions. Hard to tell whether units are stable, meaningful concepts, labeling-pipeline artifacts, or useful but model-specific basis functions.
- faithfulness dimension appears to essentially be a tie?
- given the low inter rater agreement I think some of the claims may be slightly overstated
- quantitative results in general are somewhat mixed - best AOPC on four of five backbones but not dominant on STraTS; clinical plausibility AUROCs/AUPRCs are modest and often close to TSR or WinIT
- the main table doesn't reveal as much as it could due to averaging over tasks, it's harder than it should be to understand where the method succeeds/fails
- I think the perturbation faithfulness is likely to be sensitive to the distribution of pertubatoin?
- SOFA-derived plausibility is somewhat limited given the limitations of SOFA, focuses on organ-failure physiology
- the explanation eval may be somewhat unbalanced by what is returned - i.e., while both arms use the LLM verbalizer, the TI-SAE provides concepts vs. the attributed cells which may lead to inflated comparison
- I buy that TI-SAE produces a structured, temporal, decomposition, but I don't think the evidence is strong enough to say the latents are clinically validated concepts. I think claims around model reasoning for verbalized explanations are also overstepping a bit
Questions
- Can you provide task-by-task and dataset-by-dataset results?
- Can you assess how much of the verbalization advantage comes from concept labels/cells vs. the claimed faithful underlying attribution? Ablation with TI-SAE without LLM labels? or baseline cells with a matched summarization? I think there is a way to run this experiment
- Can you expand upon low inter-rater agreement? per-item agreement is very low for some
- Can you demonstrate stability? do we see the same clinical concepts emerge across runs / initializations?
- I'd love to see a deeper analysis of the failure cases as well as explanation of what could be driving the inter-rater agreement
Limitations
Reasonable, but would benefit from futher discussion of low-inter rater clinician agreement, potential for label induced bias from the LLM concept naming, an examination of tasks where performance was suboptimal, limitations of SOFA/baseline methods. There needs to be a stronger separation/explanation of the distinction between MIMIC-III and MIMIC-IV (especially due to the fact that some patients appear in both 2008-2012, how was this handled?). I think some of the claims about dataset transfer need to be qualified / measures could be taken to ensure separation
Final justification
Original strong feedback holds buffed by the authors rebuttal to my review changing score from 4->5
Formatting concerns
Authors should add more detail about where LLMs were used vs. not as well as prompts and exact model versoin
7 comments
Rebuttal
We thank the reviewer for the careful and constructive review. Below we try to address each point.
Q4, W1: Stability of the learned units
We separate three properties, each tested by a distinct experiment: cross-seed stability of dictionary and selected concepts, coherence across patients without label, and recurrence beyond a single model.
1) Cross-seed stability of dictionary and selected concepts. Our seed-stability analysis in the paper (Appendix G.7, Table 11) retrained both stages per seed, mixing dictionary drift with selector noise, so we separated them and reran over five seeds (42-46).
| stage | metric | 5-seed mean ± SD | random null |
|---|---|---|---|
| A — dictionary (no selector) | decoder cosine | .735 ± .002 | .029 |
| variable overlap (≥2/3) | 82.4% ± 1.1% | 0.8% | |
| temporal-window cosine | .731 ± .013 | .398 | |
| energy correlation | .361 ± .010 | .083 | |
| B — selector (dictionary fixed) | top-64 concept Jaccard | .708 ± .017 | .026 |
| PS-score rank corr. (Spearman) | .87 ± .029 | ~0 |
Every metric sits above its matched null (decoder and variable composition by 25x and 100x). The selector's faithfulness is also stable across seeds: neighborhood AOPC .151 ± .008, with the paper's .149 inside the range. So the dictionary reproduces across runs, and the selector reselects a reproducible subset of the same patient's concepts across seeds.
2) Coherence across patients. The manuscript already reports clinician validation of the concept labels (mean Likert 4.07–4.40, four independent clinicians). We add a quantitative test, without labels, on 1,000 held-out patients, whether a latent fires on patients who share the same underlying variable pattern. Each active concept's ten strongest-activating patients have raw-value profiles that are far more coherent and more discriminative than random variable groupings of matched sparsity (within-concept spread .384 vs .660, lower is more coherent; discrimination .458 vs .220, higher is better). This uses only variables and decoder weights, so these exist before any label is attached, though value-level coherence and discrimination cannot fully capture the complexity of real physiologic trajectories.
3) Recurrence across backbones, and transfer to disjoint data. The variable composition of concepts recurs across five backbone architectures (78–88% grouping overlap, against a 0.7% random baseline; Appendix G.9, Table 13), so the concepts are not tied to one model's geometry. They also transfer to a strictly disjoint MIMIC-IV cohort (neighborhood AOPC .130 vs .149 MIMIC-III in-distribution, plausibility .756 unchanged). A basis tuned to one model's idiosyncratic geometry, or overfit to a single cohort, would not recur across architectures and datasets.
Q2, W8: Verbalization advantage from concept labels
The verbalization comparison is meant to mimic a clinician reading an explanation, where TI-SAE can draw on its cross-episode dictionary, so the input asymmetry was intended; but we agree that it can inflate the result and be misread. We ran two controls (same LLM verbalizer and judge, 50 episodes), reporting the concept dimension as TI-SAE wins–baseline wins (ties). (We focus on concept, where the label-inflation concern applies; on actionability the concept format is consistently rated less actionable than per-cell attributions, and on faithfulness the two are mixed and tie-heavy — full tables available.)
| TI-SAE condition | vs IG | vs Attention | vs TSR |
|---|---|---|---|
| label removed | 24-23 (3) | 16-29 (5) | 25-23 (2) |
| + cross-episode summary, no label | 31-19 (0) | 26-20 (4) | 27-21 (2) |
With its label removed, TI-SAE no longer clearly beats raw attribution cells, so most of the verbalized advantage came from the label. Adding back only the label-free cross-episode summary (variables, window, cohort frequency, odds ratio) recovers a small concept lead.
| baseline condition | vs IG | vs Attention | vs TSR |
|---|---|---|---|
| LLM-summarized (per-episode) | 11-39 (0) | 11-37 (2) | 18-30 (2) |
| channel-grouped, no label | 27-21 (2) | 29-20 (1) | 28-20 (2) |
Given a fresh per-episode LLM summary, the baseline beats TI-SAE on concept. However, that summary is a per-patient description the LLM can word freely for each case. Against the matched label-free baseline that groups the same cells into organ-channel concepts (isolating structure, not LLM wording), TI-SAE wins across all three methods.
We therefore concede the original comparison is inflated by TI-SAE returning concepts while the baseline returns cells, and that a matched per-episode LLM summary verbalizes as well. The residual point is that only TI-SAE produces cross-patient, spatiotemporally grounded concepts.
Q3, Q5, W3: Inter-rater agreement
The paper reports clinician–clinician Fleiss κ of .04, .18, and −.06 (concept, actionability, faithfulness). We agree these are low, and the paper attributes this to tie-threshold variance. Raters differ sharply in how often they call a tie (on faithfulness, one rater tied 45/50, another tied none), which Fleiss κ penalizes heavily, though genuine rater disagreement also contributes. Our primary validation signal is therefore the aggregate marginal preference, where clinician majority votes match the LLM judge's direction across all three dimensions. Consistent with this, when we restrict to cases where both raters committed to a direction, they agree on concept in 68% of comparisons (153/226; 50–87% across the six rater pairs), which indicates the low κ reflects inconsistent tie-calling together with genuine rater disagreement. We acknowledge the high tie rate itself indicates many explanation pairs are close, consistent with small quality differences in this setting.
W9: Clinical concepts
We agree the "clinical concept" claims are not fully established. We do not claim to recover the backbone's internal reasoning. The selector identifies a subset that is sufficient to reproduce the prediction, contributes non-redundantly under perturbation, and is clinically plausible, which is weaker than reasoning recovery. The concepts are supported by structural reproducibility and by clinician ratings of the concept labels, but we do not claim strict validation against clinical diagnoses and syndromes. We will correct overstated phrasings such as "validated by clinicians" accordingly. The judge dimension "concept-level reasoning" measures whether an explanation groups co-evolving variables, not whether it recovers the model's reasoning. We flag this scope in Limitation 6.
Q1, W5: Task and dataset breakdown
Per-task and per-dataset faithfulness is already in Appendix H.2 (Tables 18–32: comprehensiveness and sufficiency per fraction, all methods, for each of the 5 backbones × 3 tasks, with MIMIC-III and MIMIC-IV as sub-blocks). Across the 30 (backbone × task × dataset) cells, TI-SAE has the best neighborhood AOPC in 20. The losses are concentrated on two backbones: all 6 STraTS cells, and 3 of BAT's non-mortality cells (LOS-MIMIC-III and both readmission cells) plus Discrete LOS on MIMIC-III, where a baseline leads by a narrow margin. On mortality TI-SAE is best on all four non-STraTS backbones across both datasets (8/8). We will add the matching per-task and per-dataset plausibility tables.
W2, W4, W6: The tie, mixed results, perturbation sensitivity
On perturbation sensitivity, the reviewer is right that the ranking shifts with the scheme. TI-SAE leads on 4 of 5 backbones under neighborhood perturbation, 2 of 5 under removal, and 1 of 5 under marginal. We report all three (Appendix H.1) and headline neighborhood because it best approximates a realistic clinical counterfactual: it replaces a cell with the patient's temporally nearest observed value of the same variable, keeping the perturbed input consistent with that patient's trajectory. We do not claim faithfulness dominance under every perturbation definition. On plausibility we agree it is competitive rather than dominant: TI-SAE is best on one backbone, second on three with WinIT and TSR ahead on several, and behind on STraTS. Our claim is a representation that stays competitive to best on both while being decomposable, not that it wins every metric.
W7: SOFA as the plausibility ground truth
We agree SOFA is coarse (Limitation 4). We use it because it is the standard ICU severity score that is both organ-decomposed and natively time-resolved, which are the properties a cell-level plausibility target requires. It scores each organ system from specific variables at a point in time. APACHE II, SAPS II, and OASIS are one-time, worst-value-in-first-24h aggregate scores, a single number per admission with no temporal resolution, so they cannot serve as a proper cell-level plausibility target.
Limitation: MIMIC-III/IV overlap and a disjoint evaluation
We agree the 2008–2012 overlap must be separated, and we add a strictly disjoint evaluation. Using MIMIC-IV's anchor_year_group, we restrict the test set to the 2014–2016 and 2017–2019 bands — patients whose care is entirely after MIMIC-III's 2012 cutoff, hence disjoint by construction. The frozen MIMIC-III model transfers to this disjoint set without degradation from overlap (prediction AUROC .864; neighborhood AOPC .130, matching the full-test .128; plausibility .756). Removing the overlap therefore does not reduce prediction or faithfulness transfer, indicating the overlap was not inflating the cross-dataset result. As scope, both cohorts derive from the same source hospital system, so this addresses patient and temporal overlap but not cross-institution generalization. (Appendix G.8, Table 12's .861→.814 reflected a 500-sample evaluation draw; on the full test set the drop is .861→.857.)
We thank the reviewer again for the detailed comments, which have helped us calibrate the claims and strengthen the evidence. The new analyses will be in the camera-ready.
Official Comment by Authors [1/6]
We follow up on three points from our response, which were insufficient due to the length limit: the per-task and per-dataset breakdown (Q1, W5), the deeper look at the failure cases and inter-rater agreement (Q5), and cross-institution generalization (limitation).
Task-by-task and dataset-by-dataset results (Q1, W5)
We agree that averaging over tasks and datasets in Table 2 can hide where the method succeeds and fails, and we give the full breakdown below. Per-fraction comprehensiveness/sufficiency for every backbone × task is already in Appendix H.2, Tables 18-32; here we report the summary faithfulness (neighborhood AOPC) and plausibility (AUROC/AUPRC) for each (task × dataset) cell, all methods, best per column in bold (by AOPC for faithfulness and by AUROC for plausibility; the paired AUPRC is that method's value, not necessarily the column-best).
On faithfulness, TI-SAE has the best neighborhood AOPC in 20 of 30 (backbone × task × dataset) cells: it is best on mortality across all four non-STraTS backbones and both datasets, and its losses concentrate on all six STraTS cells and on four non-mortality cells (Discrete/LOS/MIMIC-III, BAT/LOS/MIMIC-III, and both BAT readmission cells). On plausibility, TI-SAE is competitive rather than dominant: it has the best AUROC in 9 of 30 cells, strongest on mortality, while WinIT and TSR lead on many non-mortality cells.
1) Faithfulness (neighborhood AOPC) — per task × dataset
Mortality · MIMIC-III
| Method | Discrete | Disc.+PT | HyMaTE | BAT | STraTS |
|---|---|---|---|---|---|
| TI-SAE (soft) | 0.149 | 0.091 | 0.143 | 0.065 | 0.015 |
| TI-SAE (hard) | 0.134 | 0.081 | 0.127 | 0.070 | 0.013 |
| Attention | 0.100 | 0.036 | 0.096 | -- | 0.010 |
| IG | 0.086 | 0.076 | 0.085 | 0.057 | 0.064 |
| TSR | 0.088 | 0.079 | 0.094 | 0.059 | 0.061 |
| DynaMask | 0.028 | 0.035 | 0.016 | 0.046 | 0.033 |
| TimeSHAP | 0.009 | 0.012 | 0.017 | 0.022 | 0.016 |
| FIT | 0.015 | 0.011 | 0.033 | 0.020 | 0.010 |
| WinIT | 0.035 | 0.041 | 0.056 | 0.035 | 0.025 |
| Cluster-TCAV | 0.074 | 0.020 | 0.062 | 0.056 | 0.012 |
| Random | 0.001 | 0.003 | 0.003 | 0.008 | 0.005 |
Mortality · MIMIC-IV
| Method | Discrete | Disc.+PT | HyMaTE | BAT | STraTS |
|---|---|---|---|---|---|
| TI-SAE (soft) | 0.102 | 0.109 | 0.120 | 0.085 | 0.016 |
| TI-SAE (hard) | 0.107 | 0.094 | 0.100 | 0.076 | 0.021 |
| Attention | 0.063 | 0.043 | 0.047 | -- | 0.016 |
| IG | 0.070 | 0.066 | 0.045 | 0.037 | 0.093 |
| TSR | 0.077 | 0.068 | 0.058 | 0.042 | 0.092 |
| DynaMask | 0.038 | 0.054 | 0.020 | 0.046 | 0.043 |
| TimeSHAP | 0.012 | 0.006 | 0.004 | 0.022 | 0.031 |
| FIT | 0.018 | 0.012 | 0.012 | 0.018 | 0.033 |
| WinIT | 0.036 | 0.028 | 0.022 | 0.028 | 0.052 |
| Cluster-TCAV | 0.099 | 0.026 | 0.035 | 0.028 | 0.053 |
| Random | 0.004 | 0.004 | 0.001 | 0.008 | 0.009 |
LOS>7d · MIMIC-III
| Method | Discrete | Disc.+PT | HyMaTE | BAT | STraTS |
|---|---|---|---|---|---|
| TI-SAE (soft) | 0.041 | 0.037 | 0.124 | 0.022 | 0.023 |
| TI-SAE (hard) | 0.039 | 0.034 | 0.130 | 0.020 | 0.023 |
| Attention | 0.037 | 0.002 | 0.067 | -- | 0.020 |
| IG | 0.050 | 0.032 | 0.054 | 0.025 | 0.060 |
| TSR | 0.049 | 0.034 | 0.089 | 0.034 | 0.080 |
| DynaMask | 0.022 | 0.033 | 0.021 | 0.021 | 0.048 |
| TimeSHAP | 0.012 | 0.010 | 0.008 | 0.010 | 0.031 |
| FIT | 0.009 | 0.013 | 0.031 | 0.011 | 0.018 |
| WinIT | 0.011 | 0.036 | 0.066 | 0.010 | 0.037 |
| Cluster-TCAV | 0.011 | 0.024 | 0.008 | 0.009 | 0.017 |
| Random | 0.002 | 0.001 | 0.001 | 0.004 | 0.006 |
LOS>7d · MIMIC-IV
| Method | Discrete | Disc.+PT | HyMaTE | BAT | STraTS |
|---|---|---|---|---|---|
| TI-SAE (soft) | 0.032 | 0.056 | 0.044 | 0.035 | 0.022 |
| TI-SAE (hard) | 0.035 | 0.057 | 0.043 | 0.030 | 0.022 |
| Attention | 0.015 | 0.020 | 0.026 | -- | 0.029 |
| IG | 0.029 | 0.037 | 0.018 | 0.028 | 0.056 |
| TSR | 0.033 | 0.045 | 0.030 | 0.035 | 0.059 |
| DynaMask | 0.008 | 0.035 | 0.015 | 0.027 | 0.051 |
| TimeSHAP | 0.003 | 0.012 | 0.008 | 0.017 | 0.033 |
| FIT | 0.006 | 0.013 | 0.014 | 0.010 | 0.032 |
| WinIT | 0.012 | 0.030 | 0.013 | 0.018 | 0.044 |
| Cluster-TCAV | 0.012 | 0.017 | 0.009 | 0.014 | 0.023 |
| Random | 0.002 | 0.003 | 0.001 | 0.004 | 0.010 |
Readmission · MIMIC-III
| Method | Discrete | Disc.+PT | HyMaTE | BAT | STraTS |
|---|---|---|---|---|---|
| TI-SAE (soft) | 0.106 | 0.097 | 0.055 | 0.025 | 0.010 |
| TI-SAE (hard) | 0.088 | 0.086 | 0.054 | 0.028 | 0.010 |
| Attention | 0.056 | 0.005 | 0.038 | -- | 0.008 |
| IG | 0.051 | 0.068 | 0.035 | 0.018 | 0.057 |
| TSR | 0.051 | 0.074 | 0.039 | 0.023 | 0.058 |
| DynaMask | 0.016 | 0.030 | -0.000 | 0.024 | 0.013 |
| TimeSHAP | 0.011 | 0.027 | 0.011 | 0.019 | 0.034 |
| FIT | 0.002 | 0.017 | 0.018 | 0.012 | 0.016 |
| WinIT | 0.013 | 0.040 | 0.022 | 0.026 | 0.014 |
| Cluster-TCAV | 0.043 | 0.045 | 0.040 | 0.028 | 0.011 |
| Random | 0.001 | 0.003 | 0.002 | 0.010 | 0.006 |
Official Comment by Authors [2/6]
Readmission · MIMIC-IV
| Method | Discrete | Disc.+PT | HyMaTE | BAT | STraTS |
|---|---|---|---|---|---|
| TI-SAE (soft) | 0.085 | 0.063 | 0.096 | 0.024 | 0.010 |
| TI-SAE (hard) | 0.068 | 0.058 | 0.088 | 0.022 | 0.009 |
| Attention | 0.044 | 0.010 | 0.033 | -- | 0.014 |
| IG | 0.074 | 0.026 | 0.057 | 0.022 | 0.071 |
| TSR | 0.077 | 0.024 | 0.060 | 0.031 | 0.074 |
| DynaMask | 0.005 | 0.003 | -0.002 | 0.002 | 0.018 |
| TimeSHAP | 0.009 | -0.001 | 0.026 | 0.007 | 0.032 |
| FIT | 0.015 | 0.002 | 0.022 | 0.003 | 0.017 |
| WinIT | 0.014 | 0.007 | 0.015 | 0.010 | 0.021 |
| Cluster-TCAV | 0.038 | 0.022 | 0.032 | 0.005 | 0.015 |
| Random | 0.002 | 0.003 | 0.003 | 0.001 | 0.006 |
2) Plausibility (AUROC / AUPRC) — per task × dataset
Mortality · MIMIC-III
| Method | Discrete | Disc.+PT | HyMaTE | BAT | STraTS |
|---|---|---|---|---|---|
| TI-SAE (soft) | 0.756/0.384 | 0.631/0.303 | 0.707/0.356 | 0.598/0.249 | 0.516/0.216 |
| TI-SAE (hard) | 0.639/0.313 | 0.625/0.289 | 0.621/0.301 | 0.575/0.240 | 0.506/0.218 |
| Attention | 0.615/0.258 | 0.468/0.189 | 0.568/0.231 | -- | 0.610/0.249 |
| IG | 0.567/0.254 | 0.555/0.245 | 0.641/0.278 | 0.620/0.265 | 0.621/0.251 |
| TSR | 0.594/0.279 | 0.586/0.262 | 0.673/0.320 | 0.649/0.296 | 0.636/0.264 |
| DynaMask | 0.507/0.212 | 0.507/0.205 | 0.492/0.189 | 0.491/0.189 | 0.492/0.189 |
| TimeSHAP | 0.521/0.212 | 0.521/0.214 | 0.525/0.214 | 0.526/0.218 | 0.523/0.214 |
| FIT | 0.523/0.205 | 0.547/0.219 | 0.558/0.218 | 0.489/0.191 | 0.564/0.227 |
| WinIT | 0.601/0.264 | 0.622/0.283 | 0.657/0.342 | 0.584/0.261 | 0.644/0.298 |
| Cluster-TCAV | 0.541/0.223 | 0.520/0.217 | 0.598/0.256 | 0.569/0.264 | 0.494/0.207 |
| Random | 0.502/0.193 | 0.502/0.193 | 0.502/0.193 | 0.502/0.193 | 0.502/0.193 |
Mortality · MIMIC-IV
| Method | Discrete | Disc.+PT | HyMaTE | BAT | STraTS |
|---|---|---|---|---|---|
| TI-SAE (soft) | 0.705/0.362 | 0.569/0.256 | 0.611/0.255 | 0.638/0.296 | 0.545/0.248 |
| TI-SAE (hard) | 0.632/0.314 | 0.533/0.245 | 0.556/0.232 | 0.621/0.276 | 0.561/0.252 |
| Attention | 0.668/0.312 | 0.624/0.268 | 0.523/0.203 | -- | 0.497/0.190 |
| IG | 0.562/0.231 | 0.530/0.218 | 0.595/0.246 | 0.572/0.230 | 0.541/0.208 |
| TSR | 0.578/0.244 | 0.552/0.232 | 0.619/0.269 | 0.592/0.248 | 0.564/0.218 |
| DynaMask | 0.506/0.199 | 0.491/0.193 | 0.495/0.188 | 0.515/0.202 | 0.484/0.203 |
| TimeSHAP | 0.514/0.203 | 0.512/0.203 | 0.520/0.208 | 0.519/0.207 | 0.513/0.203 |
| FIT | 0.523/0.204 | 0.532/0.207 | 0.505/0.189 | 0.495/0.191 | 0.562/0.221 |
| WinIT | 0.601/0.270 | 0.607/0.276 | 0.576/0.247 | 0.570/0.256 | 0.621/0.279 |
| Cluster-TCAV | 0.599/0.257 | 0.471/0.234 | 0.513/0.222 | 0.559/0.243 | 0.410/0.176 |
| Random | 0.501/0.191 | 0.501/0.191 | 0.501/0.191 | 0.501/0.191 | 0.501/0.191 |
LOS>7d · MIMIC-III
| Method | Discrete | Disc.+PT | HyMaTE | BAT | STraTS |
|---|---|---|---|---|---|
| TI-SAE (soft) | 0.699/0.360 | 0.514/0.197 | 0.623/0.295 | 0.633/0.279 | 0.559/0.242 |
| TI-SAE (hard) | 0.659/0.335 | 0.508/0.193 | 0.614/0.275 | 0.612/0.266 | 0.555/0.241 |
| Attention | 0.617/0.282 | 0.453/0.184 | 0.560/0.243 | -- | 0.637/0.260 |
| IG | 0.543/0.222 | 0.543/0.234 | 0.587/0.257 | 0.591/0.243 | 0.593/0.239 |
| TSR | 0.569/0.242 | 0.581/0.248 | 0.626/0.290 | 0.611/0.264 | 0.629/0.261 |
| DynaMask | 0.510/0.203 | 0.505/0.204 | 0.492/0.189 | 0.493/0.189 | 0.492/0.189 |
| TimeSHAP | 0.513/0.203 | 0.521/0.216 | 0.517/0.210 | 0.517/0.209 | 0.517/0.210 |
| FIT | 0.510/0.199 | 0.538/0.214 | 0.528/0.209 | 0.504/0.195 | 0.556/0.221 |
| WinIT | 0.575/0.242 | 0.612/0.279 | 0.602/0.265 | 0.562/0.253 | 0.640/0.310 |
| Cluster-TCAV | 0.463/0.196 | 0.453/0.195 | 0.423/0.198 | 0.556/0.225 | 0.421/0.199 |
| Random | 0.502/0.193 | 0.502/0.193 | 0.502/0.193 | 0.502/0.193 | 0.502/0.193 |
LOS>7d · MIMIC-IV
| Method | Discrete | Disc.+PT | HyMaTE | BAT | STraTS |
|---|---|---|---|---|---|
| TI-SAE (soft) | 0.312/0.181 | 0.629/0.263 | 0.588/0.255 | 0.525/0.219 | 0.601/0.244 |
| TI-SAE (hard) | 0.417/0.217 | 0.572/0.237 | 0.541/0.244 | 0.499/0.217 | 0.606/0.249 |
| Attention | 0.523/0.220 | 0.619/0.260 | 0.577/0.236 | -- | 0.477/0.181 |
| IG | 0.516/0.214 | 0.535/0.232 | 0.606/0.263 | 0.564/0.239 | 0.552/0.220 |
| TSR | 0.544/0.230 | 0.565/0.249 | 0.644/0.298 | 0.587/0.259 | 0.580/0.237 |
| DynaMask | 0.500/0.198 | 0.500/0.199 | 0.495/0.188 | 0.474/0.186 | 0.494/0.188 |
| TimeSHAP | 0.512/0.203 | 0.521/0.212 | 0.525/0.217 | 0.517/0.212 | 0.514/0.204 |
| FIT | 0.519/0.210 | 0.542/0.220 | 0.521/0.193 | 0.466/0.180 | 0.551/0.222 |
| WinIT | 0.567/0.241 | 0.618/0.296 | 0.595/0.252 | 0.563/0.247 | 0.610/0.272 |
| Cluster-TCAV | 0.420/0.171 | 0.341/0.153 | 0.348/0.162 | 0.382/0.165 | 0.465/0.188 |
| Random | 0.501/0.191 | 0.501/0.191 | 0.501/0.191 | 0.501/0.191 | 0.501/0.191 |
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper introduces a temporal island sparse autoencoder to learn clinical concept dictionaries (detailing when the concept is active plus the variables included) from a model's predictive representations. They evaluate their model on two mimic datasets compared to baselines and perform an ablation study.
Strengths and weaknesses
Clarity: This paper is clear with an organized structure, easy to understand methods and formulation and understandable graphics.
Significance: Better ways to characterize and understand clinical events and concepts from EHRs in model predictions is of high importance to the biomedical community. Introduction of a new method linking model outputs with specific clinical concepts, including when the concept is relevant and what features contribute, could be extremely useful in clinical contexts to understand model performances and shortcomings.
Originality: This paper has strong originality with the development of a new type of explainable autoencoder. In particular, the presentation of a concept dictionary learned from temporal gaussian islands and a variable composition vector is very interesting and novel formulation in this space (e.g., a new way to formulate and understand what patterns the model is learning that contribute to model prediction.)
Quality: This paper appears technically sound with reasonable methods and experimentation, though there are a couple of weaknesses. How stable are the learned concept dictionaries? While this formulation is very interesting, it is not very useful if the learned dictionaries have high noise or variability across patients, model runs or datasets (see Question 1). Additionally, a notable drawback of this approach is that the latent characterization of the dictionaries is learned post-hoc. Some evidence of value is provided in Section 5.2 but how detailed, specific and trustworthy are these post-annotated summaries? Are the dictionaries clearly separable with obvious groupings or statistical significance? (See Question 2). Finally, how generalizable is this approach? It is worth noting that only one type of dataset was tested on since Mimic III and MIMIC IV are very similar. Does this method work on other EHR datasets or contexts? Testing on a secondary more unique EHR dataset would significantly strengthen the paper (see Question 3).
Questions
- How stable are the learned concept dictionaries?
- How detailed, specific and trustworthy are the post-hoc latent summaries for the dictionaries? Are they clearly separable with obvious groupings or statistical significance?
- Were any other non mimic datasets used? How generalizable is this method to other EHR datasets/contexts or even clinical scenarios outside EHRs?
Limitations
Yes
Final justification
I maintain my score. I believe this paper has strong significance and originality, good technical soundness and presentation. Moreover, my questions surrounding stability of the learned concept dictionaries, detail and trustworthiness of the latent summaries and potential model generalization were adequately answered so I have no remaining concerns.
Formatting concerns
N/A
5 comments
Rebuttal
We thank the reviewer for the positive and thoughtful assessment. We address the three questions below.
Q1: Stability of the learned dictionaries
The reviewer asks whether the dictionary is noisy or variable across model runs, patients, and datasets. We tested each.
1) Across model runs. Our seed-stability analysis in the paper (Appendix G.7, Table 11) retrained both stages per seed. We separately retrain the dictionary and then the selector over five seeds (Discrete backbone, MIMIC-III mortality) and measure reproduction:
| stage | metric | 5-seed mean ± SD | random null |
|---|---|---|---|
| A — dictionary (no selector) | decoder cosine | .735 ± .002 | .029 |
| variable overlap (≥2/3) | 82.4% ± 1.1% | 0.8% | |
| temporal-window cosine | .731 ± .013 | .398 | |
| energy correlation | .361 ± .010 | .083 | |
| B — selector (dictionary fixed) | top-64 concept Jaccard | .708 ± .017 | .026 |
| PS-score rank corr. (Spearman) | .87 ± .029 | ~0 |
Every metric is well above its matched null, and the selector's faithfulness is stable across seeds (neighborhood AOPC .151 ± .008, with the paper's .149 inside the range). The dictionary structure also recurs across five different backbone architectures (variable-composition overlap 78–88% vs 0.7% random; Appendix G.9, Table 13), so it is not tied to one model.
2) Across patients. We add a quantitative test, without labels, on 1,000 held-out patients, to see whether a latent fires on patients who share the same underlying variable pattern. For each active concept, its ten strongest-activating patients have raw-value profiles that are far more coherent and more discriminative than random variable groupings of matched sparsity (within-concept spread .384 vs .660, lower is more coherent; discrimination .458 vs .220, higher is better). This uses only variables and decoder weights, so the coherence exists before any label is attached, though value-level coherence and discrimination cannot fully capture the complexity of real physiologic trajectories. Furthermore, the paper reports clinician validation of the concept labels (mean Likert 4.07–4.40, four independent clinicians).
3) Across datasets (see Q3). the frozen MIMIC-III model transfers to a strictly disjoint MIMIC-IV cohort with modest domain-shift drop.
Q2: Detail, specificity, and trustworthiness of the summaries; separability, groupings, significance
We address the two halves separately: whether the dictionary is structurally separable, with groupings and significance, and whether the post-hoc summaries are detailed, specific, and trustworthy. The structural analysis below is new for this response; the exemplars and clinician ratings are in the paper.
1) Separability. We measure separability by how correlated two concepts' activations are across patients, because the decoder cosines here are uninformative: with 3-sparse atoms over ~135 variables, active mean .025 and shuffled null .020 are both near zero. By this activation correlation, concepts are largely uncorrelated: mean absolute correlation .125, with only 1.4% of concept pairs exceeding .5, suggesting concepts fire in distinct contexts rather than duplicating one another.
2) Groupings. The concepts do not form a few tight clusters (k-means gives a low silhouette, .073); the dictionary is fine-grained rather than a handful of coarse groups. There is a mild organ-level tendency (concepts in the same organ have more similar variable composition, .107 vs .008 across organs), but this partly follows from organ being defined by a concept's variables and from the channel-purity regularizer.
3) Statistical significance. We tested each active concept for association with the outcome (active-versus-inactive mortality odds ratio with a 95% CI). Of 479 concepts, 385 (80%) are significant: 223 with OR >1 and 162 with OR <1. The remaining 20% we report as non-significant.
4) Detailed and specific. Each concept is defined by a sparse set of variables, one or more temporal windows, and an outcome odds ratio. Appendix G.3 and G.4 give the dictionary overview and hand-picked exemplars, for example "Acute Kidney Injury with Oliguria" (OR 5.09): rising BUN and creatinine with declining urine output over the window, coherent across its exemplar episodes. The specificity lives in this structure, not in the label wording — label wording does not track concept distinctness (some families reuse a template phrase across functionally distinct concepts), so we treat the label as a readable overlay and rely on the structure and outcome associations above.
5) Trustworthy. Four tertiary-hospital clinicians rated the concept labels favorably (mean Likert 4.07–4.40 on a 5-point scale, N=30). This is post-hoc, expert-judged support that the concepts are clinically reasonable; we do not claim validation against formal diagnoses, consistent with the calibration in our other responses.
Q3: Other datasets and generalizability
We have evaluated on MIMIC-III and MIMIC-IV only; we have not yet completed a non-MIMIC dataset. We agree the two are similar and that a genuinely independent EHR source is the right test. We are working on eICU Collaborative Research Database, a multi-center US ICU database from a different hospital network, though preprocessing and adaptation is taking time. We will try to provide eICU results during the discussion period but cannot guarantee they will be ready in time, and we prefer not to report preliminary numbers.
Within MIMIC we can offer one partial form of generalization: a strictly disjoint MIMIC-IV cohort (patients admitted from 2014 on, entirely after MIMIC-III's cutoff). The frozen MIMIC-III dictionary transfers to it with modest domain-shift drop (neighborhood AOPC .130 vs .149 in-distribution; plausibility preserved at .756).
Several factors affect where this method will generalize, including whether the setting has a rich enough set of variables and enough observation density to form concepts with a temporal extent. We would expect poor generalization to long outpatient trajectories due to severe sparsity, but general inpatient settings should be workable, though sparser than the ICU.
Outside EHRs, it could in principle apply to other dense, irregular multivariate time series, especially where complex spatiotemporal dependencies matter, but we scope our empirical claims to ICU-like EHR settings.
We thank the reviewer again for the encouraging assessment and the questions, which have helped us strengthen the paper. We will incorporate the new analyses from this response into the camera-ready.
Thanks for your detailed response. My questions have been adequately answered and I maintain my score.
We thank the reviewer for engaging with our response and for maintaining the positive assessment. We follow up on one point about the evaluation on a non-MIMIC dataset: an independent, institution-level external evaluation on the eICU Collaborative Research Database (eICU-CRD).
eICU-CRD: an independent, multi-center external evaluation
eICU-CRD is drawn from a different hospital network (208 US hospitals) than MIMIC. We processed the data based on the published ricu repository (variable definitions, source-table mappings, and unit-conversion conventions), extended to improve variable coverage and harmonize units to the MIMIC ontology. The cohort is prepared with identical criteria to our MIMIC cohorts: the first ICU stay per patient, age ≥ 18, unit length-of-stay ≥ 48h, with a known discharge status (63,038 stays, in-hospital mortality ≈ 11%, 98 variables), hourly-binned over a 48h window. For the transfer evaluation the eICU variables are mapped onto the MIMIC ontology, dropping the 9 eICU-only variables that have no MIMIC counterpart (CVP, PEEP, EtCO2, RASS, MPV, Total Protein, and the eICU-specific infusions dexmedetomidine, diltiazem, dobutamine), which leaves 89 variables mapped onto the MIMIC-III ontology.
We then re-ran the whole evaluation suite for the Discrete backbone on the mortality task, to see whether the contribution carries over.
1) Transfer. The frozen MIMIC-III model predicts mortality on eICU-CRD at AUROC 0.803 (MIMIC-III: .861). Out-of-distribution transfer preserves the method ranking; TI-SAE ranks first among the methods we evaluated:
| Method | neighborhood AOPC | SOFA plausibility |
|---|---|---|
| TI-SAE (soft) | .158 | .707 |
| TI-SAE (hard) | .148 | .588 |
| Attention | .113 | .593 |
| IG | .065 | .543 |
| TSR | .066 | .560 |
| DynaMask | .041 | .491 |
| TimeSHAP | .034 | .512 |
| WinIT | .042 | .552 |
| Random | .010 | .498 |
2) Native training. A model trained from scratch on eICU-CRD (prediction AUROC 0.851) also ranks first among the evaluated methods (± values are bootstrap standard deviations with 2000 resamples):
| Method | neighborhood AOPC | SOFA plausibility |
|---|---|---|
| TI-SAE (soft) | .088 ± .008 | .691 ± .007 |
| TI-SAE (hard) | .082 ± .008 | .652 ± .006 |
| Attention | .067 ± .008 | .602 ± .008 |
| IG | .046 ± .006 | .483 ± .004 |
| TSR | .045 ± .007 | .474 ± .005 |
| DynaMask | .053 ± .006 | .491 ± .007 |
| TimeSHAP | .021 ± .006 | .499 ± .002 |
| WinIT | .030 ± .005 | .496 ± .006 |
| Random | .006 ± .002 | .499 ± .003 |
The dictionary contribution reproduces on eICU as well, using the natively trained model: island-identity stability under 5% event dropout (Jaccard .892 vs random .013); concept-knockout that degrades the prediction monotonically and faster than random removal at every k; and, in a matched pairwise verbalization comparison (LLM judge, 50 episodes), a preference for TI-SAE on the concept dimension over IG (30–20) and TSR (32–18), roughly even with attention (24–23). The learned concepts also carry coherent outcome associations, with 76% of active concepts carrying a statistically significant mortality odds ratio. Representative high-risk and protective concepts include:
| eICU concept | mortality OR |
|---|---|
| Refractory Vasoplegic Shock | 9.5 |
| Lymphopenia with Severe Sepsis | 8.9 |
| Severe Sepsis, Broad-Spectrum Antibiotics | 8.6 |
| Refractory Hypoxemic Respiratory Failure | 8.2 |
| Mechanical Ventilation with Respiratory Failure | 7.9 |
| Baseline Hematologic Adequacy | 0.10 |
| Hemodynamic Stability with Cardiac Monitoring | 0.11 |
| Procedural Sedation and Analgesia | 0.12 |
| Alert Neurological Status Without Sedation | 0.13 |
| Sustained Amiodarone Antiarrhythmic Therapy | 0.13 |
We thank the reviewer again for the encouraging assessment, and for the question that prompted this evaluation.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Official Comment by Authors [1/2]
We thank the Area Chair for the detailed meta-review. Below we map each of the eight decision-relevant points to where it is answered. Points 1–7 were each raised by a reviewer and are addressed in full in our per-reviewer responses and follow-up official comments (Reviewers oxGc, ShNf, 8yxd); we summarize them here and give the pointer. Point 8 was not raised by any reviewer, so we treat it in full here.
1) Cross-seed and cross-patient stability of the dictionary and the selected concepts. Both stages are stable. With the backbone fixed, the dictionary reproduces across seeds (decoder cosine .735 vs .029 null); with the dictionary fixed, the selector's importance ranking is highly consistent across seeds (Spearman .87) and its faithfulness is unchanged (.151 ± .008, with the paper's .149 in the range); and the concepts are coherent across patients under a label-free test. Detail: Reviewers oxGc (Q1), ShNf (Q4, W1), and 8yxd (Q1, W1).
2) Isolating the dictionary from the selector. With a matched selection objective and budget on each representation, raw hidden states collapse (neighborhood AOPC .038), a standard SAE without islands recovers faithfulness but not plausibility (.155 / .568), and TI-SAE recovers both (.149 / .756). A learned dictionary is necessary for the faithfulness gain, and the temporal islands add the temporal structure that makes the concepts readable. Detail: Reviewer 8yxd (Q2, W2).
3) Clinical meaning given low inter-rater agreement and post-hoc LLM labels. With labels stripped, TI-SAE's bare concepts no longer clearly beat per-cell attribution, and a matched per-episode LLM summary verbalizes as well, though that summary is a per-patient description the LLM can word freely for each case. Nonetheless, only TI-SAE produces cross-patient, spatiotemporally grounded concepts. The low inter-rater κ is driven by heterogeneous tie-calling, genuinely close explanation pairs, and genuine rater disagreement. Detail: comment to Reviewer ShNf (Q2, W8 / Q3, Q5, W3).
4) Restrictiveness of symmetric Gaussian windows. A Gaussian window does not represent a concept's activation trajectory. It is a temporal support gate that indicates when a concept is active, while the activation strength is carried by the encoder output. Replacing the symmetric window with a split-normal (skewed) one, learned or fixed, changes neither faithfulness nor plausibility, even though the model uses the skew heavily when free; and because a concept's mask is the clamped sum of its M windows, it is able to represent various patterns. Detail: comment to Reviewer 8yxd (Q3, W3).