potentialpaper

Rest-Tuning: Data-Efficient Adaptation of EEG Foundation Models to Individuals via Resting-State Signals

Yinuo Zhang, Xinyu Fu, Qing Wang, Yinte Zhang, Junjie Yu, Kexin Lou, Quanying Liu

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. Rest-Tuning personalizes EEG foundation models using just minutes of unlabeled resting-state data, producing reusable subject-specific backbones that improve multi-task performance and reduce labeled data needs.

Abstract. Subject-specific distribution shifts make personalization a central challenge for EEG foundation models (FMs). We propose Rest-Tuning, a task-agnostic calibration framework that personalizes a population FM using just 1–3 minutes of unlabeled resting-state EEG. Rest-Tuning aligns masked student representations with intact-view targets from a frozen population teacher, combining contrastive discrimination with pointwise consistency to produce a reusable subject-calibrated backbone. Across two multi-subject datasets and four EEG FMs, Rest-Tuning outperforms task-only adaptation, achieving accuracy gains of up to 13.3 percentage points and reducing the required labeled-data fraction by over 40 percentage points on average. A single resting calibration also supports task adaptation across sessions up to two weeks later, extending its utility beyond the initial recording session. Calibration requires less than three minutes of computation per subject on average, and its cost is shared across subsequent tasks. Representation analyses show reduced subject-to-population distance, further LoRA interpolation analyses suggest improved rest–task and cross-task compatibility. These results establish Rest-Tuning as a practical, fast, and reusable calibration interface that translates population EEG FMs into personalized backbones for data-efficient decoding across tasks and sessions.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
2 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:44 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

Summary

This paper proposes Rest-Tuning, a two-stage subject-calibration framework that personalizes pretrained EEG foundation models (FMs) using 1–3 minutes of unlabeled resting-state EEG. Stage 1 applies a masked teacher-student contrastive alignment objective to adapt a frozen population FM to a target subject without task labels. Stage 2 uses the calibrated backbone as initialization for downstream task adaptation (linear probing, LoRA, or full fine-tuning). The paper claims: (1) consistent accuracy gains across four EEG FMs and two datasets; (2) 20–60% reduction in labeled data requirements; (3) calibration saturation in 60–120 seconds; (4) task-agnostic reusability across multiple downstream tasks; and (5) reduced subject-to-population representational distance via Wasserstein analysis and smoother LoRA interpolation paths.

Strengths

  • Practical motivation and clean framing. All three reviewers agree the premise — using trivially-collected resting-state EEG as a universal calibration signal — is well-motivated and targets a genuine practical bottleneck in BCI deployment (4uPN, 7cAz, Fqe6).
  • Consistent empirical gains across diverse settings. Two reviewers (4uPN, 7cAz) explicitly note consistency across four architecturally distinct FMs and multiple adaptation interfaces, indicating the direction is robust rather than model-specific.
  • Mechanistic analysis beyond accuracy. All three reviewers credit the Wasserstein distance and LoRA interpolation analyses as valuable attempts to explain why the method works (4uPN, 7cAz, Fqe6).
  • Data and compute efficiency. Saturation at 1–3 minutes and under 3 minutes of compute, with amortized per-task cost, makes this realistically deployable (4uPN, Fqe6).

Main Weaknesses

  • Missing methodological details and insufficient ablation. The projection head in Eq. (4) is not clearly defined (trained vs. frozen, initialized from scratch vs. pretrained). The combination of contrastive loss with data2vec-style masked student-teacher is insufficiently motivated — no direct comparison isolates the contribution of each loss term. The λ sweep (Table A5) operates within standard deviation ranges on a single FM/dataset, and other design choices (mask ratio, masking strategy) lack systematic ablation despite evidence of sensitivity (different ρ for Rest-Full vs. Rest-LoRA) (7cAz, 4uPN).
  • Cross-session generalization entirely untested. For a method framed around "reusable" calibration, the absence of cross-session evaluation is significant. It is unknown whether the approach requires re-calibration for each new session (4uPN, Fqe6).
  • Missing positioning relative to prior resting-state calibration work. Reviewer 7cAz identifies that calibrating BCI models on resting-state data has been explored before (Kwak et al. 2023, An et al. 2024). The paper does not discuss these methods. The novelty claim must be re-positioned to articulate what Rest-Tuning adds beyond these approaches (7cAz).
  • Mechanistic analyses not generalized. The Wasserstein distance analysis and saturation curves are shown only for LaBraM on COGBCI. It is unclear whether the representational alignment story holds for other backbones (4uPN, Fqe6).

Questions That Could Adjust Acceptance Odds

If the authors successfully address these prioritized questions, I would need the following in the author response to significantly increase the odds toward acceptance:

  • [Critical] Clarify missing methodological details and ablation gaps. Define the projection head (architecture, initialization, trained/frozen). Provide a direct comparison between the contrastive term and the MSE term — is their combination necessary or does one dominate? Clearly motivate the combination of masking and contrastive losses.
  • [Critical] Test cross-session generalization on COGBCI. COGBCI contains multi-session recordings. Calibrate on Session 1 resting-state and evaluate on Session 2 task data. Report whether recalibration is needed and how gains degrade across sessions.
  • [Important] Position relative to Kwak et al. (2023) and An et al. (2024). Clearly explain how Rest-Tuning differs in scope (task-agnostic vs. task-specific), requirements (single-subject rest-only vs. multi-subject rest-task pairs), and applicability (FM-agnostic vs. model-specific). If possible, provide a brief empirical comparison on a shared setting.
  • [Important] Generalize the alignment analysis. Report Wasserstein distance reductions for at least one additional backbone (e.g., CBraMod, which shows large accuracy gains). This clarifies whether the mechanistic story is general or LaBraM-specific.
Final justification

The authors submitted thorough point-by-point responses with substantial new experiments. Reviewer 7cAz engaged across four exchange rounds and raised their score from 2 to 3, explicitly crediting the added experiments. Reviewer 4uPN acknowledged all concerns as addressed and increased confidence from 3 to 5, maintaining Borderline Accept (4). Reviewer Fqe6 did not respond to the rebuttal. Final ratings: 3-4-4.

All four questions from the initial meta-review are substantively resolved. Critical items: (1) methodological details are clarified – the projection head is a parameter-free reshape, a loss-term ablation shows both InfoNCE and MSE contribute significantly, a mask-ratio sweep validates defaults, and a matched MAE baseline confirms Rest-Tuning outperforms generic self-supervision by 2.4–6.0 pp; (2) cross-session generalization is demonstrated on all 29 COGBCI subjects – calibrating once on Session 1 rest and reusing the frozen backbone 1-2 weeks later yields positive gains. Important items: (3) prior work (BCM/ResTL) is differentiated along scope, data requirements, and reusability; (4) alignment analysis now spans three backbones and two datasets.

Regarding Reviewer 7cAz's remaining concern about significance: the authors use contrastive objectives to perform task-agnostic subject calibration of pre-trained EEG FMs. I interpret this as a distinct combination of existing tools in a new context. The cross-session experiment clarifies practical feasibility of the approach. Together with the systematic evidence across four foundation models, six tasks, and 124 subjects in the original submission, I am inclined to recommend acceptance.

Area Chair 9BxC · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

Summary

This paper proposes Rest-Tuning, a two-stage subject-calibration framework that personalizes pretrained EEG foundation models (FMs) using 1–3 minutes of unlabeled resting-state EEG. Stage 1 applies a masked teacher-student contrastive alignment objective to adapt a frozen population FM to a target subject without task labels. Stage 2 uses the calibrated backbone as initialization for downstream task adaptation (linear probing, LoRA, or full fine-tuning). The paper claims: (1) consistent accuracy gains across four EEG FMs and two datasets; (2) 20–60% reduction in labeled data requirements; (3) calibration saturation in 60–120 seconds; (4) task-agnostic reusability across multiple downstream tasks; and (5) reduced subject-to-population representational distance via Wasserstein analysis and smoother LoRA interpolation paths.

Strengths

  • Practical motivation and clean framing. All three reviewers agree the premise — using trivially-collected resting-state EEG as a universal calibration signal — is well-motivated and targets a genuine practical bottleneck in BCI deployment (4uPN, 7cAz, Fqe6).
  • Consistent empirical gains across diverse settings. Two reviewers (4uPN, 7cAz) explicitly note consistency across four architecturally distinct FMs and multiple adaptation interfaces, indicating the direction is robust rather than model-specific.
  • Mechanistic analysis beyond accuracy. All three reviewers credit the Wasserstein distance and LoRA interpolation analyses as valuable attempts to explain why the method works (4uPN, 7cAz, Fqe6).
  • Data and compute efficiency. Saturation at 1–3 minutes and under 3 minutes of compute, with amortized per-task cost, makes this realistically deployable (4uPN, Fqe6).

Main Weaknesses

  • Missing methodological details and insufficient ablation. The projection head in Eq. (4) is not clearly defined (trained vs. frozen, initialized from scratch vs. pretrained). The combination of contrastive loss with data2vec-style masked student-teacher is insufficiently motivated — no direct comparison isolates the contribution of each loss term. The λ sweep (Table A5) operates within standard deviation ranges on a single FM/dataset, and other design choices (mask ratio, masking strategy) lack systematic ablation despite evidence of sensitivity (different ρ for Rest-Full vs. Rest-LoRA) (7cAz, 4uPN).
  • Cross-session generalization entirely untested. For a method framed around "reusable" calibration, the absence of cross-session evaluation is significant. It is unknown whether the approach requires re-calibration for each new session (4uPN, Fqe6).
  • Missing positioning relative to prior resting-state calibration work. Reviewer 7cAz identifies that calibrating BCI models on resting-state data has been explored before (Kwak et al. 2023, An et al. 2024). The paper does not discuss these methods. The novelty claim must be re-positioned to articulate what Rest-Tuning adds beyond these approaches (7cAz).
  • Mechanistic analyses not generalized. The Wasserstein distance analysis and saturation curves are shown only for LaBraM on COGBCI. It is unclear whether the representational alignment story holds for other backbones (4uPN, Fqe6).

Questions That Could Adjust Acceptance Odds

If the authors successfully address these prioritized questions, I would need the following in the author response to significantly increase the odds toward acceptance:

  • [Critical] Clarify missing methodological details and ablation gaps. Define the projection head (architecture, initialization, trained/frozen). Provide a direct comparison between the contrastive term and the MSE term — is their combination necessary or does one dominate? Clearly motivate the combination of masking and contrastive losses.
  • [Critical] Test cross-session generalization on COGBCI. COGBCI contains multi-session recordings. Calibrate on Session 1 resting-state and evaluate on Session 2 task data. Report whether recalibration is needed and how gains degrade across sessions.
  • [Important] Position relative to Kwak et al. (2023) and An et al. (2024). Clearly explain how Rest-Tuning differs in scope (task-agnostic vs. task-specific), requirements (single-subject rest-only vs. multi-subject rest-task pairs), and applicability (FM-agnostic vs. model-specific). If possible, provide a brief empirical comparison on a shared setting.
  • [Important] Generalize the alignment analysis. Report Wasserstein distance reductions for at least one additional backbone (e.g., CBraMod, which shows large accuracy gains). This clarifies whether the mechanistic story is general or LaBraM-specific.
Final justification

The authors submitted thorough point-by-point responses with substantial new experiments. Reviewer 7cAz engaged across four exchange rounds and raised their score from 2 to 3, explicitly crediting the added experiments. Reviewer 4uPN acknowledged all concerns as addressed and increased confidence from 3 to 5, maintaining Borderline Accept (4). Reviewer Fqe6 did not respond to the rebuttal. Final ratings: 3-4-4.

All four questions from the initial meta-review are substantively resolved. Critical items: (1) methodological details are clarified – the projection head is a parameter-free reshape, a loss-term ablation shows both InfoNCE and MSE contribute significantly, a mask-ratio sweep validates defaults, and a matched MAE baseline confirms Rest-Tuning outperforms generic self-supervision by 2.4–6.0 pp; (2) cross-session generalization is demonstrated on all 29 COGBCI subjects – calibrating once on Session 1 rest and reusing the frozen backbone 1-2 weeks later yields positive gains. Important items: (3) prior work (BCM/ResTL) is differentiated along scope, data requirements, and reusability; (4) alignment analysis now spans three backbones and two datasets.

Regarding Reviewer 7cAz's remaining concern about significance: the authors use contrastive objectives to perform task-agnostic subject calibration of pre-trained EEG FMs. I interpret this as a distinct combination of existing tools in a new context. The cross-session experiment clarifies practical feasibility of the approach. Together with the systematic evidence across four foundation models, six tasks, and 124 subjects in the original submission, I am inclined to recommend acceptance.

1 comment
Authors · CommentOpenReview ↗

Response to the Meta-Review

Dear AC,

Thank you for the structured metareview and for identifying the two Critical and two Important questions most relevant to the acceptance decision. During rebuttal, we added targeted experiments and clarifications that we believe substantively address all four priorities.

[Critical] Method details and ablation gaps

  • Projection head. g(⋅)g(\cdot) is a parameter-free reshape, neither trained nor pretrained; the teacher applies stop-gradient, so gradients flow only through the student (7cAz, Q2).
  • Objective design. Masking prevents near-identity matching between identically initialized branches; InfoNCE preserves inter-window discrimination; MSE provides negative-free anchoring when correlated rest windows act as imperfect negatives (7cAz, W3). We also identified CoMET as a close EEG precedent for masked student–target contrastive learning and will cite and discuss it prominently.
  • Isolating each loss term's contribution. In a loss-term ablation on all 29 COGBCI subjects, the full InfoNCE–MSE objective achieves the highest performance, and removing either term causes significant degradation (7cAz, W3).
  • Sensitivity of the remaining design choices. A mask-ratio sweep supports the selected defaults (ρ=0.3ρ=0.3 for Rest-Full, ρ=0.7ρ=0.7 for Rest-LoRA) (7cAz, W3), and λMSEλ_{MSE} changes accuracy by at most 2.01 pp over a 100-fold range across two backbones, two datasets, and both budgets (7cAz, W4).
  • Matched SSL control. Under matched data, parameterization, and downstream interfaces, Rest-Tuning also significantly exceeds matched MAE calibration by 2.36 pp with LoRA and 5.96 pp with full tuning, showing that the gains are not explained solely by additional masked self-supervision (7cAz, second follow-up).

[Critical] Cross-session generalization

We evaluated all 29 COGBCI subjects: calibrate once with Session-1 rest, freeze the calibrated backbone, and reuse it one and two weeks later, training only a session-specific linear head with 10% of that session's labels. Rest-Full yields positive gains in all 8 Session-2/3 comparisons across two backbones and unitask/multitask settings, with 7/8 reaching p<0.05p<0.05. This shows that subject-specific information learned from Session-1 rest remains accessible without recalibrating the backbone (4uPN, W5; Fqe6, W1).

[Important] Positioning relative to Kwak et al. and An et al.

BCM/ResTL require multi-subject paired rest–task data and per-task retraining; Rest-Tuning uses only target-subject rest, calibrates once, and reuses the initialization across tasks. In our 29-subject deployment comparison, total training time was 2.93–8.81 min versus 60.00–122.56 min for BCM/ResTL. Given differences in backbones, supervision, and label access, this supports lower deployment burden rather than a controlled accuracy ranking (7cAz, W1; 4uPN, W4).

[Important] Alignment generalization

We extended the Wasserstein analysis from LaBraM–COGBCI to CBraMod–COGBCI, LaBraM–M3CV, and BIOT–COGBCI. All four combinations show significant paired reductions p<10−10p<10^{-10}, covering three backbones and both datasets (4uPN, W2/Q1; Fqe6, Q2).

State of the discussion. Reviewer 4uPN called the expanded alignment analysis "a real improvement" and cross-session reuse well addressed. Reviewer 7cAz confirmed W1, Q2–Q5, and M1–M2 resolved, found the loss-weight analysis more convincing, and raised the score from 2 to 3. The added cross-session and cross-backbone analyses also directly target Reviewer Fqe6’s two main concerns.

Remaining disagreement: contribution level and venue fit. Reviewer 7cAz frames the paper as either a new universal SSL objective requiring broad SSL benchmarks or a routine application of existing SSL that is unsuitable for NeurIPS. We respectfully disagree with this dichotomy. Rest-Tuning claims neither: its contribution lies at the FM-adaptation level, formulating target-rest-only, post-pretraining/pre-task calibration with a frozen population prior and one calibration reusable across tasks, interfaces, and later sessions. We do not claim novelty for the individual SSL primitives. Rather, to our knowledge, prior EEG FM work has not systematically formulated and validated this target-rest-only, calibrate-once-and-reuse regime across backbones, tasks, interfaces, and sessions. Relative to BCM/ResTL, it avoids multi-subject paired rest–task data and per-task retraining, reducing deployment burden. The ablations, matched MAE control, separate-task results, and cross-session study directly test this method-level claim.

We respectfully ask that Rest-Tuning be assessed as a distinct and practically consequential EEG foundation-model adaptation method: target-rest-only, prior-preserving, and calibrate-once-and-reuse, with systematic evidence across backbones, tasks, adaptation interfaces, and sessions. We believe the updated record addresses all four priorities in the metareview and supports reconsideration toward acceptance.

Reviewer Fqe6OpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
4/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes Rest-Tuning. It is a task-agnostic calibration framework that personalizes EEG foundation models to individual subjects using 1 to 3 minutes of unlabeled resting-state EEG. It uses a masked teacher-student contrastive objective to align a trainable student network to a frozen population model. The resulting subject-calibrated backbone is reused across multiple downstream tasks. Experiments are conducted on two datasets and four EEG foundation model backbones. THe result shows consistent improvement in downstream task accuracy and reduction in labeled data requirements.

Strengths and weaknesses

The idea of using resting-state EEG as a task-agnostic calibration signal is interesting and practical. Resting EEG is easy to collect and does not require task labels, making this a realistic approach for real-world BCI deployment. The data efficiency analysis and LoRA interpolation analysis add useful insight beyond just accuracy.

However, the experiment is not adequate: four backbone models, two datasets, and six downstream tasks. Cross-session stability is not discussed; therefore, the train and test split strategy is not very clear by the reader.

Quality. The gains vary largely across backbones. EEGPT shows only marginal improvement in most settings, and the discussion is not enough.

Clarity. The paper is well-written.

Significance. The practical motivation is good, but the paper only tests within-session performance. Without cross-session results, it is unclear whether the calibrated backbone stays useful.

Originality. The main novelty is applying an existing self-supervised learning recipe to EEG subject calibration. The technical contribution is limited.

Questions

Q1. EEGPT shows only marginal improvement in most settings compared to other backbones. For example in Table 1, EEGPT with the gain of 0.7 (Rest-LoRA) and 0.22 (Rest-Full) compares to CbraMod with the gain of 13.19 (Rest-LoRA) and 13.25 (Rest-Full). What is the reason? A further explanation is helpful.

Q2. The subject-to-group alignment analysis is only for COGBCI with LaBraM. Is this pattern also valid for other backbones?

Limitations

Rest-Tuning is only evaluated on two datasets. The inconsistent gains across backbones, especially for EEGPT, are not discussed sufficiently. Additionally, the proposed Rest-Tuning is only evaluated on two datasets with fixed montages. Due to EEG tipycall have difference montage across tasks due to different devices, the model's capability to deal with such a variety is not clear for Rest-Tuning

Formatting concerns

No major formatting or anonymity concerns.

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for recognizing the practical value of Rest-Tuning. In summary, we have addressed each concern raised: (1) a cross-session evaluation on all 29 COGBCI subjects, showing that a single Session-1 calibration remains useful one and two weeks later, with substantially more consistent evidence for Rest-Full (W1); and (2) an extension of the subject-to-group Wasserstein alignment analysis to CBraMod–COGBCI and LaBraM–M3CV, confirming that the alignment pattern is not specific to LaBraM (Q2). We also clarify the within-session train/test split protocol (W1), provide an explicit discussion of the backbone-dependent gains for EEGPT (Q1), and will state the montage and evaluation-scope limitations prominently in the revision.

W1. Evaluation protocol and cross-session stability

The original main experiments are subject-specific and within-session; we now clarify the split and add a cross-session evaluation. For each subject and task, task trials are class-stratified into deterministic training, validation, and test splits using seed 42. Task-only and Rest-Tuning models use identical split indices and downstream adaptation interfaces. Resting EEG is used only for Stage-1 calibration and provides no downstream labels. The exact split implementation is available in our released code.

We additionally evaluated whether one calibration remains useful across sessions. On all 29 COGBCI subjects, we calibrated once using Session-1 rest, froze and reused the calibrated backbone, and independently trained a linear head using 10% of each session’s task labels. Each head was evaluated on the corresponding session’s held-out test set. The task-only control used the same pretrained backbone, labels, and linear-probing protocol without rest calibration. Sessions were one week apart, and NBack represents the unitask setting. Freezing the backbone isolates whether the subject-specific information learned from Session-1 rest remains accessible in later sessions without further backbone adaptation.

Backbone Setting Initialization S1 S2 (+1 week) S3 (+2 weeks)
LaBraM Multitask Task only 27.76 ± 6.42 27.07 ± 6.98 29.18 ± 5.46
LaBraM Multitask Rest-LoRA 31.06 ± 6.86 (+3.30)† 30.65 ± 5.65 (+3.58)† 30.11 ± 4.96 (+0.93)
LaBraM Multitask Rest-Full 31.28 ± 6.73 (+3.52)† 28.89 ± 7.05 (+1.82)† 30.80 ± 5.27 (+1.62)†
LaBraM NBack Task only 41.61 ± 8.24 41.77 ± 8.85 43.82 ± 9.11
LaBraM NBack Rest-LoRA 44.15 ± 8.69 (+2.54)† 43.62 ± 9.28 (+1.85)† 45.42 ± 9.44 (+1.60)†
LaBraM NBack Rest-Full 44.22 ± 8.13 (+2.61)† 42.45 ± 7.35 (+0.68) 45.66 ± 7.63 (+1.84)†
CBraMod Multitask Task only 19.53 ± 2.48 18.97 ± 3.84 19.04 ± 2.68
CBraMod Multitask Rest-LoRA 22.33 ± 4.05 (+2.80)† 18.46 ± 2.00 (−0.51) 18.95 ± 2.28 (−0.09)
CBraMod Multitask Rest-Full 26.00 ± 6.03 (+6.47)† 24.24 ± 6.20 (+5.27)† 25.08 ± 5.08 (+6.04)†
CBraMod NBack Task only 33.89 ± 2.71 34.83 ± 3.74 33.56 ± 2.04
CBraMod NBack Rest-LoRA 35.86 ± 5.51 (+1.97) 35.15 ± 3.11 (+0.32) 34.66 ± 3.39 (+1.10)
CBraMod NBack Rest-Full 46.75 ± 9.47 (+12.86)† 39.89 ± 7.38 (+5.06)† 41.38 ± 6.85 (+7.82)†

Bold indicates a positive mean gain over task-only; † denotes a condition-specific paired t-test with p<0.05p<0.05, n=29n=29.

Across the eight S2/S3 comparisons, Rest-Full retains positive mean gains in all settings, seven of which reach p<0.05p<0.05. Rest-LoRA is positive in six of eight comparisons, with three reaching p<0.05p<0.05. Thus, one Session-1 calibration remains useful for up to two weeks under the tested acquisition protocol, with substantially more consistent evidence for Rest-Full.

Q1. Why are EEGPT gains smaller in some settings?

The gains are backbone- and interface-dependent, but EEGPT is not uniformly unresponsive. Several EEGPT LoRA gains are small, whereas Rest-Full + Task-Full yields +11.96+11.96 pp on M3CV Unitask and +6.55+6.55 pp on COGBCI Multitask. A plausible partial explanation is the relative adaptation capacity: EEGPT contains 25.29M encoder parameters, while its LoRA interface updates 524,288 parameters, or only 2.03% of the model, compared with 3.03% for CBraMod and 5.00% for LaBraM. Although EEGPT has more trainable LoRA parameters in absolute terms, they span a smaller fraction of its backbone and may provide a more restrictive update subspace. The stronger Full + Full results are consistent with this explanation, but do not establish it causally. We will therefore describe the gains as positive but dependent on the backbone and adaptation interface.

We also identified a reporting error in Appendix Table A3: the EEGPT parameter counts were inadvertently duplicated from CBraMod. The correct EEGPT counts are 25,287,168 total/trainable parameters for Full tuning, and 25,811,456 total parameters with 524,288 trainable parameters (2.03%) for LoRA tuning. This reporting correction does not affect the experimental configurations or performance results.

Q2. Does representation alignment generalize beyond LaBraM?

Yes, for the additional combinations tested. Using the same leave-one-subject-out construction, we compared each subject's Wasserstein distance before and after Rest-Tuning:

Backbone–Dataset nn Pretrained Rest-Tuning Paired test
CBraMod–COGBCI 29 798.16±28.72 176.81±4.90 p=1.19×10−18,dz=−3.89p=1.19\times10^{-18}, d_z=-3.89
LaBraM–COGBCI 29 104.59±5.74 28.68±2.91 p=9.07×10−13,dz=−2.28p=9.07\times10^{-13}, d_z=-2.28
LaBraM–M3CV 95 113.37±4.39 8.53±1.93 p=3.03×10−18,dz=−3.76p=3.03\times10^{-18}, d_z=-3.76

Because representation scales differ across backbones, the relevant evidence is the paired pre/post reduction within each combination, not the absolute distance across backbones. These results extend the alignment finding to CBraMod and across datasets.

Limitations and contribution scope

The cross-session pilot uses the same dataset, montage, and acquisition protocol; it does not establish robustness to device changes or electrode repositioning. Likewise, two datasets and four FMs do not cover all montage, tokenization, or clinical settings. We will state these limitations explicitly. We also agree that the masked teacher-student and contrastive primitives are not individually new. The contribution is the target-rest-only, task-agnostic calibration regime, together with evidence that one calibrated FM can be reused across tasks, adaptation interfaces, and, in the new pilot, later sessions.

Authors · CommentOpenReview ↗

Dear Reviewer,

As the discussion period approaches its conclusion, we would like to briefly follow up on the main concerns raised in your review.

We added a cross-session evaluation on all 29 COGBCI subjects, showing that a single calibration using Session-1 resting EEG remains useful one and two weeks later. In particular, Rest-Full yields positive gains in all eight Session-2/3 comparisons, across LaBraM and CBraMod, with seven reaching statistical significance.

We also substantially expanded the subject-to-group alignment analysis. Beyond the original LaBraM–COGBCI result, we evaluated CBraMod–COGBCI (p=1.19×10−18p=1.19\times10^{-18}, dz=−3.89d_z=-3.89), BIOT–COGBCI (p=7.41×10−11p=7.41\times10^{-11}, dz=−1.88d_z=-1.88), and LaBraM–M3CV (p=3.03×10−18p=3.03\times10^{-18}, dz=−3.76d_z=-3.76). All tested combinations show significant paired reductions in Wasserstein distance, extending the evidence to three backbones and both datasets. We additionally clarified the backbone- and interface-dependent behavior of EEGPT, specified the within-session evaluation protocol, and explicitly acknowledged the remaining limitations regarding montage and device generalization.

We hope these additions address your primary concerns regarding cross-session stability, cross-backbone alignment, and variation across foundation models. If you consider these concerns sufficiently addressed, we would sincerely appreciate your reconsideration of the overall rating before the discussion period closes.

We would be happy to clarify any remaining concern.

Reviewer 7cAzOpenReview ↗
Rating
3/6
Confidence
4/5
Quality
2/4
Clarity
2/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper proposes Rest-Tuning, a two-stage subject-level adaptation method for EEG foundation models (FMs).

  • Stage 1 finetunes the pre-trained FM on some (unlabeled) resting state recording from the target subject, via a self-supervised objective combining a contrastive loss and an MSE term. For stage 1, they compare full fine-tuning and LoRA.
  • Stage 2 fine-tunes the FM on labeled task data with a supervised objectives. Fro stage 2, they compare linear probing, LoRA, and full fine-tuning.

Stages 1 and 2 are executed sequentially.

The method is evaluated on four EEG-FMs (LaBraM, BIOT, CBraMod, EEGPT) and two datasets: M3CV (95 subjects: resting-state, sensory/P300, motor paradigms) and COGBCI (29 participants, session 1: NBack and MATB workload).

The authors report consistent downstream gains and include a subject-to-group alignment analysis to explain the effect.

Strengths and weaknesses

Strengths

  • Relevant problem. Subject-level adaptation from unlabeled resting-state EEG targets a practical question: how a model is actually calibrated for a new user. The EEG-FM literature usually neglects it and evaluates on unrealistic protocols (e.g., cross-subject fine-tuning).
  • Consistent empirical effect. The reported improvements hold across all four backbones and across tasks, indicating the direction is worth pursuing.
  • Mechanistic analysis. The subject-to-group alignment analysis is a useful attempt to explain why the method helps, rather than only reporting accuracy.

Weaknesses

  • Missing literature on resting state calibration. Calibrating BCI models on resting state data is not a novel idea. It particular, this has already been explored in the context of deep learning models for motor imagery classification by Kwak et al. (2023) and An et al. (2024). The contribution must be re-positioned relative to these.
  • Missing SSL literature. The Stage-1 SSL objective is close to existing JEPA / MAE / contrastive SSL methods that were already applied to EEG, but the paper does not explain how it builds on or differs from them.
  • Unclear motivation for the contrastive loss. The contrastive term of the SSL loss combines a CLIP objective with a student/teacher setup with masking (JEPA/data2vec style). This choice is very uncommon but is not motivated. Also, the influence of the two loss terms is never directly compared.
  • Weak support for the loss weighting. The λMSE=0.1\lambda_{MSE} = 0.1 choice is based on a sweep over a single model and a single dataset (Table A5), but all reported values fall by a large margin within the standard deviation range and don't apear to be significant.
  • No standard benchmark. Evaluation is limited to the M3CV and COGBCI datasets. As the evaluation is not done on a standard benchmark (e.g., NeuralBench, OpenEEGBench, NeuroAtlas), scores cannot be compared across papers and it is more difficult to check if the baselines are faithfully reproduced. This is a recurring problem in the field of EEG-FM, and the comunity must converge to a standard benchmark.

Minor

  • Figure 3a ("after" panel): I believe the labels should be DrestD^{rest} and PrestP^{rest}.
  • Figure 4 is hard to understand and requires several back and fourth with the methods section. Also I belive there is an inconsistency: the figure refers to an α\alpha parameter while the methods section uses λ\lambda. The explanation should be clarified.

References

Questions
  • Would the method work on the far more abundant unlabeled inter-trial recordings rather than dedicated resting-state blocks? Combined with a standard benchmark, this would substantially strengthen the paper.
  • The projection head gg in Eq. (4) is not clearly defined: is it trained or frozen? And is it initialized from scratch or pretrained? Please clarify.
  • Figures 4a-c: at α=1\alpha = 1, why do Rest-Tuning and the random baseline differ? Should they not coincide on the end point?
  • Figures 4d-4f each combine two tasks and report an accuracy score, but on which task is it computed?
  • Section 3.5 refers to a parameter λ\lambda while Figure 4 uses α\alpha. Are these the same parameter?
Limitations

n/a

Final justification

The additional experiments strengthen the publication, so I will increase my grade 2 -> 3. I will stay below the acceptance threshold because of W2 and W3:

  • if we establish that you are only adapting an SSL objective to task-agnostic subject calibration, then I think this paper is not the right fit for NeurIPS (it might be of more interest to the BCI community, at a BCI conference)
  • if we agree that the SSL objective is indeed novel, then the experiments in the paper are not suited to demonstrating its relevance and impact: the data is too niche, you do not evaluate on a well-established benchmark, and you do not compare to the right baselines
Formatting concerns

no

6 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the constructive assessment. We clarify Rest-Tuning’s positioning relative to BCM/ResTL, including a 29-subject comparison (W1), position its contribution relative to established EEG SSL (W2), add loss-term and mask-ratio ablations (W3), extend loss-weight sensitivity across backbones and datasets (W4), and address the benchmark, implementation, notation, and figure-clarity concerns (W5/Q1–Q5).

W1. Missing resting-state literature

BCM(Kwak et al., 2023) and ResTL(An et al., 2024) are cited in the manuscript as Refs. [21-22] and discussed in Sec. 2, but we agree the distinction was not explicit. The key difference is the data structure and reuse regime, not whether rest is used. BCM and ResTL learn a task-specific transfer mapping from paired rest–task recordings of multiple source subjects; each new downstream task therefore requires new paired data and retraining. Rest-Tuning requires no rest–task pairs in calibration: it calibrates the FM once per subject using only the target subject's unlabeled rest EEG, before any task is specified, and the calibrated backbone is reused across tasks and adaptation interfaces.

Dimension BCM/ResTL Rest-Tuning (ours)
Scope Task-specific correction or transfer Task-agnostic pre-task subject calibration
Requirements Multi-subject rest–task pair data Target-subject unlabeled rest only
Applicability Task-specific; repeated per task Calibrate once and reuse across tasks

We also evaluated BCM/ResTL on all 29 COGBCI subjects. Because their supervision regimes differ, we report this as a deployment comparison rather than a label-matched superiority claim (Reviewer 4uPN W4).

W2. Missing SSL literature

We agree and will explicitly position Rest-Tuning relative to prior EEG SSL methods. We will add representative methods including BENDR (Kostas et al., 2021), which uses masked contrastive prediction; MAEEG (Chien et al., 2022), which reconstructs masked EEG features; and EEG2Rep (Foumani et al., 2024), which predicts masked latent representations. These works establish masked, contrastive, and representation-prediction objectives for population-level EEG pretraining.

Rest-Tuning does not claim novelty in these SSL primitives. Its distinction is their operating regime: it applies self-supervision after population pretraining to calibrate an existing EEG FM using only 1–3 minutes of unlabeled target-subject resting EEG, before the downstream task or labels are specified. The resulting subject-specific initialization can then be reused across tasks and adaptation interfaces. We will revise Sec. 2 and 3.2 to cite these methods and explicitly frame our objective as an adaptation of established EEG SSL principles to task-agnostic subject calibration.

BENDR (Kostas et al., 2021) https://doi.org/10.3389/fnhum.2021.653659

MAEEG (Chien et al., 2022) https://arxiv.org/abs/2211.02625

EEG2Rep (Foumani et al., 2024) https://doi.org/10.1145/3637528.3671600

W3. Calibration objective: motivation and ablations

Calibration adapts the encoder by optimizing it directly on unlabeled data from the target subject, while contrastive learning provides the objective that guides this adaptation. For each rest window, the trainable encoder processes a masked view, while the frozen pretrained encoder provides the representation of its unmasked view. InfoNCE brings these matched representations together and treats other windows as negatives, preventing representational collapse and preserving inter-window variation (Wang & Isola, 2020). Repeating this objective across the target subject’s resting data adapts the encoder to that subject’s signal statistics, while the frozen branch provides a stable population reference. However, with only 1–3 minutes of same-subject rest, correlated windows may act as false negatives and be unnecessarily separated. MSE therefore provides direct, negative-free alignment to the frozen reference, limiting drift from the population-pretrained space.

(Wang & Isola, 2020) https://dl.acm.org/doi/10.5555/3524938.3525859

Loss-term ablation. We evaluated LaBraM with Rest-Full + Task-Full on all 29 COGBCI subjects. Reported p-values are from paired subject-level tests against the Full objective.

Objective InfoNCE MSE 10% Acc.(%) Δ from Full p vs. Full 70% Acc.(%) Δ from Full p vs. Full
No Rest-Tuning — — 39.68±7.44 4.74 5.6E-7*** 73.44±9.53 4.69 3.2E-18***
MSE only ✗ ✓ 42.28±9.27 2.14 3.8E-3** 75.80±9.71 2.33 1.9E-2*
InfoNCE only ✓ ✗ 41.31±8.72 3.11 3.5E-3** 77.03±10.07 1.10 0.15
Full objective ✓ ✓ 44.42±9.82 — Ref. 78.13±9.45 — Ref.

Removing InfoNCE significantly reduces accuracy at both label budgets, whereas removing MSE causes a significant reduction at 10%. The full objective achieves the highest mean in both settings.

Mask-ratio sensitivity. We also swept ρ∈{0.1, 0.3, 0.5, 0.7, 0.9} using the same backbone and dataset at the 10% label budget. Rest-Full(ρ=0.3) and Rest-LoRA(ρ=0.7) attain their highest means at their respective defaults.

ρ Rest-Full+Task-Full(%) Rest-LoRA+Task-LoRA(%)
No Rest-Tuning 39.68±7.44 37.50±6.13
0.1 43.16±9.72 38.45±6.79
0.3 44.42±9.82 39.41±6.84
0.5 43.41±9.42 39.02±6.95
0.7 43.17±9.52 39.78±7.24
0.9 42.22±9.15 39.01±7.32

W4. Robustness to the loss weight

We extended the original analysis across backbones and datasets, evaluating LaBraM and CBraMod on COGBCI and LaBraM on M3CV under both 10% and 70% label budgets.

Dataset Backbone Label budget λMSE=0.01λ_{MSE}=0.01 λMSE=0.1λ_{MSE}=0.1 λMSE=1.0λ_{MSE}=1.0
COGBCI LaBraM 10% 43.91 ± 9.83 44.42 ± 9.82 42.99 ± 9.15
COGBCI LaBraM 70% 77.88 ± 9.01 78.13 ± 9.45 77.28 ± 9.46
COGBCI CBraMod 10% 49.63 ± 9.94 50.17 ± 8.84 49.43 ± 9.26
COGBCI CBraMod 70% 71.71 ± 9.47 73.69 ± 8.62 73.72 ± 8.56
M3CV LaBraM 10% 28.57 ± 4.13 28.98 ± 3.85 27.96 ± 4.03
M3CV LaBraM 70% 49.29 ± 7.55 49.79 ± 7.71 49.60 ± 7.43

Across this 100-fold range, accuracy varies by at most 2.01 pp; λMSEλ_{MSE}=0.1 is best in five of six settings and only 0.03 pp below the best in the sixth. We therefore treat it as a stable default.

W5. Why not evaluate on a standard benchmark?

We agree that standardized EEG-FM evaluation is important for cross-paper comparability. However, evaluating Rest-Tuning requires subject-linked unlabeled rest and downstream task recordings; evaluating reuse across tasks and sessions additionally requires preserving task and session identities for the same subjects. The cited benchmarks standardize downstream task evaluation but, as currently released, do not provide this paired calibration structure. Running them unchanged would therefore evaluate task-only adaptation rather than the proposed rest-calibrate-then-adapt protocol. We will clarify this selection criterion and release the exact splits, preprocessing, and baseline configurations; integration into a calibration-capable benchmark is future work.

Q1. Could unlabeled inter-trial EEG replace a dedicated rest block?

The framework can accept unlabeled inter-trial windows without architectural changes, but their effectiveness remains untested. However, inter-trial signals may retain task context, anticipation, motor preparation, or post-response activity, which could alter the subject-specific information learned during calibration. We therefore restrict the current empirical claim to resting EEG. We identify inter-trial calibration, combined with evaluation on a standard benchmark as the reviewer suggests, as a concrete future experiment.

Q2. What is the projection head g(⋅)g(\cdot)?

In our implementation, g(⋅)g(\cdot) is a parameter-free reshape operation used only to arrange the encoder outputs into the representation shape required by the calibration loss. It is neither trained nor pretrained. The teacher branch additionally applies stop-gradient; thus, gradients are propagated only through the student encoder. We will state this explicitly in Sec. 3.2 and Appendix G.

Q3. Different endpoints at α=1 in Figures 4a–c

The interpolation path is

W(α)=W0+(1−α)ΔWtask+αΔWrest.W(α)=W_0+(1-α)\Delta W_{task}+α\Delta W_{rest}.

where W0W_0 denotes the pretrained backbone parameters. Thus, α=0 gives the task-supervised adapter, α=1 gives the rest-calibrated adapter without task supervision. The red and black curves differ at α=1 because they use different rest adapters: Rest-Tuning learns ΔWrest\Delta W_{rest} from unlabeled target-subject rest EEG, whereas the random baseline uses a randomly initialized LoRA adapter of the same rank. The higher endpoint accuracy indicates that the learned rest adapter provides a more useful initialization than a random adapter of the same rank.

Q4. Accuracy reported in Figures 4d–f

Figures 4d–f show task-to-task interpolation. For each paired set of tasks and each interpolation point, we evaluate the interpolated model on the corresponding held-out test set of each task and report the arithmetic mean of the two accuracies. The individual task results are reported separately in Appendix Figure A4. We will clarify this evaluation procedure in the figure caption.

M1 & M2 & Q5 and figure clarity

The notation is indeed inconsistent: Sec. 3.5 uses λ, whereas Fig. 4 uses α, for the same interpolation coefficient. We will use α consistently in the equations, axes, and captions. In Fig. 3a, the "after" label should be

Drest=W(Psubrest,Pgrouprest).D^{rest} = W(P_{sub}^{rest},P_{group}^{rest}).

we will correct it. We will also expand the Fig. 4 caption to define the endpoints, random control, task pairs, and averaging procedure so the figure can be read without repeatedly consulting Sec. 3.5.

Reviewer 7cAz · CommentOpenReview ↗

Dear authors, thank you for answering my questions and remarks point by point.

W2. and W3.

Thank you for providing the ablation on the loss terms and the sweep over ρ\rho, they help to better understand the impact of each. And thank you for also providing the SSL literature and positioning yourself with respect to it.

However, you frame your objective as "an adaptation of established EEG SSL principles to task-agnostic subject calibration", and I don't agree on that aspect: I maintain that the contrastive loss term is very uncommon. I have never seen a CLIP objective combined with a student/teacher setup with masking (JEPA / data2vec style). I don't think your answer to W3 provides a good enough motivation for this uncommon choice.

I would be interested in the other reviewers' opinions on this aspect.

W4. Robustness to the loss weight

Thank you for this additional experiment. This is more convincing than the ablation in the paper.

W5. Why not evaluate on a standard benchmark?

Deferred to future research. I concede that evaluating on a standard benchmark would not be an easy task, as you need access to the unlabeled inter-trial windows. But I maintain that it would strengthen your publication.

Q1. Could unlabeled inter-trial EEG replace a dedicated rest block?

Deferred to future research.

W1, Q2, Q3, Q4, M1, M2 and Q5

All of these were answered, clarified or resolved in the rebuttal.

Overall recommendation

The additional experiments strengthen the publication, so I will increase my grade 2 -> 3. I will stay below the acceptance threshold because of W2 and W3:

  • if we establish that you are only adapting an SSL objective to task-agnostic subject calibration, then I think this paper is not the right fit for NeurIPS (it might be of more interest to the BCI community, at a BCI conference)
  • if we agree that the SSL objective is indeed novel, then the experiments in the paper are not suited to demonstrating its relevance and impact: the data is too niche, you do not evaluate on a well-established benchmark, and you do not compare to the right baselines
Authors · CommentOpenReview ↗

Clarification on the SSL Objective, Baselines, and Contribution

Thank you again for the clarification and for increasing the score. We agree that our previous wording—“an adaptation of established EEG SSL principles”—was imprecise and contributed to ambiguity about the intended contribution. Rest-Tuning formulates and systematically validates a post-pretraining, task-agnostic calibration protocol that uses only unlabeled resting EEG from the target subject and a frozen population prior to produce a reusable subject-specific initialization.

On the SSL objective (W2/W3). We respectfully believe that the masked student–teacher contrastive construction used in Rest-Tuning has close precedents. Our objective is not the symmetric multimodal CLIP objective, but a one-directional, in-batch InfoNCE objective between masked-view student and intact-view teacher representations. Close precedents include ConMIM (Yi et al., 2023), which trains a masked online encoder against unmasked momentum targets using InfoNCE; CMAE (Huang et al., 2024), which combines masked and full-view momentum branches with contrastive learning; and CoMET (Li et al., 2025), which applies a masked-encoder/momentum-target contrastive design to EEG. Although their training regimes differ from Rest-Tuning, these works show that masked student/target contrastive learning is not unprecedented. We will revise the manuscript to position our objective more precisely relative to them.

The construction serves a specific role in Rest-Tuning. Because both branches start from the same population-pretrained model, intact-to-intact consistency would be nearly trivial at initialization. Masking instead creates a non-trivial conditional representation-prediction problem: the student must recover the teacher’s intact-view representation from partial target-subject evidence. The frozen teacher provides a stable population reference under only 1–3 minutes of resting data, while the contrastive term adds relative batchwise identification beyond pointwise consistency. The provided loss ablation supports this design.

To test whether the gains merely result from additional self-supervised training on resting EEG, we also implemented a standard MAE calibration baseline on LaBraM, using the same target-subject resting data, calibration parameterization, and downstream adaptation interface as Rest-Tuning.

Stage-1 calibration objective Task adaptation 10% Acc. (%) Paired p vs. matched Rest-Tuning
MAE-LoRA Task-LoRA 37.42±6.74 2.76E-5***
Rest-LoRA Task-LoRA 39.78±7.24 Ref.
MAE-Full Task-Full 38.46±9.20 1.95E-4***
Rest-Full Task-Full 44.42±9.82 Ref.

Rest-Tuning significantly improves over matched MAE calibration by 2.36 pp with LoRA and 5.96 pp with full calibration, showing that its gains cannot be explained solely by additional masked self-supervised training.

On the contribution and evaluation. We respectfully disagree that the contribution must fall into either of the two alternatives in the overall recommendation. To our knowledge, prior EEG foundation-model work has not formalized and systematically evaluated the setting addressed here: calibrating a population model from a short, unlabeled pre-task resting recording, before downstream tasks or labels are known, and reusing the resulting subject-specific initialization across tasks. Rest-Tuning is therefore neither a new universal SSL objective nor merely a task-specific application of an existing loss. Its contribution lies in the rest-only calibrate-once-and-reuse problem formulation, the frozen-population-prior calibration protocol, and systematic cross-task validation under limited target-subject data.

This distinction also determines the appropriate evaluation protocol. Evaluating Rest-Tuning as a calibrate-then-adapt framework requires subject-linked pre-task resting EEG, subsequent task recordings, and reuse of the calibrated initialization across tasks. Existing standard EEG benchmarks do not currently expose this calibration-and-reuse structure; applying them unchanged would test task-only adaptation rather than our central claim. We instead evaluate two subject-linked datasets, 124 subjects, six downstream tasks, four EEG foundation models, multiple adaptation interfaces, and complementary analyses of label efficiency, calibration cost, representation alignment, and adapter compatibility. These experiments directly test whether rest-derived subject calibration provides a reusable initialization for subsequent task adaptation. We will revise the manuscript to make this scope explicit and agree that a standardized calibration-capable benchmark would be valuable.

ConMIM(Yi et al., ICLR, 2023): https://arxiv.org/pdf/2205.09616
CMAE(Huang et al., TPAMI, 2024): https://ieeexplore.ieee.org/document/10330745
CoMET(Li et al., 2025): https://arxiv.org/abs/2509.00314

Reviewer 4uPNOpenReview ↗
Rating
4/6
Confidence
5/5
Quality
3/4
Clarity
4/4
Significance
3/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper introduces Rest-Tuning, a subject-calibration framework for personalizing EEG foundation models (FMs) using short unlabeled resting-state recordings. The core idea is to run a masked teacher-student alignment stage on 1–3 minutes of resting EEG before any task-specific supervision, producing a reusable subject-calibrated backbone. The frozen teacher preserves the population prior while a trainable student learns to reconstruct masked resting windows, optimized with a contrastive InfoNCE loss plus an MSE consistency regularizer. The resulting backbone is then used as initialization for downstream task adaptation via linear probing, LoRA, or full fine-tuning. Experiments span two multi-subject EEG datasets (M3CV and COGBCI) and four EEG FMs (LaBraM, BIOT, CBraMod, EEGPT), showing consistent accuracy gains, reduced label requirements, and improved representational alignment.

Strengths and weaknesses

This work addresses the central challenge of inter-subject distribution shift in EEG decoding, widely acknowledged as one of the most persistent obstacles to practical BCI deployment. Below I organize my assessment along the four dimensions of Quality, Clarity, Significance, and Originality.

Strengths

Practical motivation and clean framing. The proposed Rest-Tuning framework is well-motivated and practically appealing. Resting-state EEG requires no task design or labeling effort, and the 1-3 minute calibration saturation result makes the approach realistically deployable in clinical and consumer BCI settings. The separation of subject calibration from task learning is conceptually clean and the reusability argument is well-articulated.

Experimental breadth. Four architecturally diverse EEG foundation models are evaluated across two datasets covering sensory, cognitive, and motor paradigms, with multiple adaptation interfaces including linear probing, LoRA, and full fine-tuning. Gains are generally consistent across settings, and the authors do not suppress variance or cherry-pick favorable comparisons.

Representation-level analysis. The Wasserstein distance reduction and LoRA adapter interpolation curves provide mechanistic support beyond raw accuracy numbers. These analyses meaningfully strengthen the claim that Rest-Tuning reshapes subject-specific feature geometry rather than simply adding compute.

Data efficiency result. Demonstrating that a single resting calibration reduces labeled task data requirements by 20-60% across downstream tasks is a meaningful practical finding, particularly in low-resource BCI contexts where labeled trial collection is expensive or fatiguing.

Weaknesses

Limited methodological novelty. The method is essentially standard self-supervised learning applied per-subject as a calibration stage. Masked reconstruction, InfoNCE contrastive loss, and teacher-student alignment are all well-established components. The contribution is primarily in the application framing and reusability argument rather than in any new technical mechanism. Readers expecting a methodological advance should calibrate expectations accordingly.

Alignment analysis is not cross-backbone. The subject-to-group Wasserstein distance analysis is shown only for LaBraM on COGBCI. Given that the paper claims broad generalization across four foundation models and two datasets, it is unclear whether the representational alignment benefit is consistent or specific to this pairing. This limits how confidently one can accept the mechanistic interpretation in Section 4.3.

Artificial multi-task construction. The multi-task evaluation merges paradigms into a single multi-class problem via strided label mapping. While computationally convenient, this does not reflect standard BCI multi-task practice, where separate decoders are typically trained per task and performance is averaged. The sensitivity of reported gains to this construction is not analyzed.

Limited comparison with prior resting-state methods. The comparison with ResTL in Table A7 is conducted on only five subjects due to computational cost. While understandable, this makes it difficult to draw strong conclusions about the relative advantage of Rest-Tuning over the most relevant existing baseline.

Cross-session generalization untested. For a method positioned as a practical BCI calibration interface, the absence of any cross-session or cross-day evaluation is a notable gap. Real-world BCI users would recalibrate across sessions, and it is unclear how Rest-Tuning benefits degrade with electrode repositioning, fatigue, or time elapsed since calibration. The authors acknowledge this but do not offer even a pilot analysis on the multi-session COGBCI data, which would have been feasible.

Saturation analysis is backbone-specific. The rest duration versus accuracy curve is shown only for LaBraM. Whether the 60-120 second saturation point generalizes to CBraMod or EEGPT, which show weaker overall gains, is not established. This matters for practitioners deciding how much rest data to collect when using different backbones.

Questions
  1. The alignment analysis is shown only for LaBraM on COGBCI. Do the Wasserstein distance reductions hold consistently across other backbone and dataset combinations, or is there meaningful variance across foundation models? If Rest-Tuning does not reliably reduce subject-to-group distance for some backbones, that would complicate the mechanistic interpretation offered in Section 4.3 and weaken the claim that representation alignment is a general property of the method rather than a model-specific artifact.

  2. Calibration saturates at roughly 60-120 seconds of resting EEG for Rest-Full with LaBraM. Is this saturation curve similar for Rest-LoRA and for other backbones such as CBraMod and EEGPT, which show weaker overall gains? Understanding whether saturation behavior correlates with the magnitude of downstream benefit would help practitioners decide how much rest data to collect and whether the 1-3 minute recommendation generalizes across architectures.

  3. The multi-task evaluation merges paradigms into a single multi-class problem via strided label mapping. How sensitive are the reported multi-task gains to this particular construction? Would results differ substantially if tasks were decoded separately and accuracy averaged, as is more common in the BCI literature? A brief analysis of this would clarify whether the gains reflect genuine multi-task representation improvement or are partly an artifact of the label space construction.

  4. Rest-Tuning is positioned as reusable across tasks from the same subject. Is there any evidence that the calibrated backbone remains useful across sessions separated by days or weeks? Even a small pilot analysis on the multi-session COGBCI data would substantially strengthen the practical motivation, since real-world BCI deployment almost always involves repeated sessions with the same user.

  5. The teacher network is frozen at population parameters throughout calibration. Was any ablation considered where the teacher receives a light momentum update, as in standard momentum-contrast style methods? Given that the frozen teacher may itself be misaligned with the target subject at the start of calibration, it is worth understanding whether a more adaptive teacher would improve or destabilize the alignment process, particularly for subjects who are especially far from the population prior.

Limitations

The authors address limitations reasonably in Section 5, noting non-stationarity of EEG, absence of cross-session tests, and sensitivity to resting EEG recording quality. These are the right limitations to flag and the discussion is honest. A few additional points would strengthen the limitations section.

The assumption of artifact-free resting recordings deserves more explicit treatment. The method's dependence on clean input EEG may be a meaningful constraint in ambulatory, pediatric, or clinical settings where compliance with resting protocols is difficult to enforce and preprocessing pipelines may not fully remove motion artifacts or electrode noise. It is not clear how gracefully Rest-Tuning degrades when resting data quality is poor.

The reusability claim is scoped to multiple tasks from the same subject within a single session. The paper does not test whether the calibrated backbone transfers across sessions, across days, or after any change in electrode placement. For a method framed around reducing the burden of repeated calibration, this is a consequential untested assumption that should be stated more prominently as a limitation rather than a future direction.

The evaluation is limited to two datasets and four foundation models, all using CNN-Transformer architectures pretrained on relatively similar EEG recording setups. It is unclear how Rest-Tuning would behave on foundation models pretrained on more heterogeneous data sources, on models with very different tokenization strategies, or on subjects with atypical neural profiles such as those with neurological conditions.

Finally, the computational cost comparison with task-only adaptation is presented favorably by amortizing the Rest-Tuning cost across multiple tasks. However, in single-task deployment scenarios, which remain common in practice, Rest-Tuning adds overhead without the amortization benefit. This trade-off should be acknowledged more directly in the limitations rather than only in the efficiency analysis.

Final justification

The authors provided point-by-point response to my questions and concerns, and performing new analyses and experiments.

W2/Q1. Does representation alignment generalize beyond LaBraM? The authors performed this generalization analysis across backbones and datasets.This is a real improvement over the original reported results.

W5/Q4. Does one calibration remain useful across sessions? This now well addressed in the rebuttal.

W4. Comparison with prior resting-state methods Expanded from 5 to 29 subjects, which is great. However, as acknowledged, it is difficult to claim a strong relative advantage over other methods.

W1. Limited methodological novelty. This is a reframing of contribution, which is an acceptable response, but doesn't change the limited novelty assessment. Taking into account the rebuttal and follow up responses, the originality score 2 still stands.

W3/Q3. Is the multitask gain an artifact of strided label mapping? The authors successfully and satisfactory answered the question. No further comment/question on this.

W6/Q2. Saturation analysis is backbone-specific. Reasonable and satisfactory answer.

Q5. Why use a frozen rather than momentum-updated teacher? Thanks for the clarification. No further question on this.

I appreciate all the efforts that the authors have put into running additional generalization and comparison analysis. However, there is limited methodological novelty and the original rating stands.

Formatting concerns

None.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for recognizing the practical motivation, experimental breadth, and representation analysis of Rest-Tuning. In summary, we have addressed each concern with new experiments: a cross-session evaluation showing one Session-1 calibration remains useful two weeks later, under a conservative frozen-backbone linear-probe protocol (W5/Q4); a cross-backbone Wasserstein analysis on CBraMod–COGBCI and LaBraM–M3CV (W2/Q1); an extended saturation analysis for Rest-LoRA and CBraMod (W6/Q2); and a 29-subject comparison with BCM/ResTL (W4). We also show multitask gains persist under separate per-task decoding (W3/Q3), clarify the frozen-teacher choice (Q5), and will make all scope limitations explicit.

W2/Q1. Does representation alignment generalize beyond LaBraM?

Yes. We extended the analysis across both backbones and datasets. Using the same leave-one-subject-out construction, we analyzed all available subjects in each dataset (COGBCI:n=29; M3CV:n=95) and paired each subject's Wasserstein distance before and after Rest-Tuning:

Backbone–Dataset n Pretrained Rest-Tuning Paired test
CBraMod–COGBCI 29 798.16±28.72 176.81±4.90 p=1.19×10−18,dz=−3.89p=1.19\times10^{-18}, d_z=-3.89
LaBraM–COGBCI 29 104.59±5.74 28.68±2.91 p=9.07×10−13,dz=−2.28p=9.07\times10^{-13}, d_z=-2.28
LaBraM–M3CV 95 113.37±4.39 8.53±1.93 p=3.03×10−18,dz=−3.76p=3.03\times10^{-18}, d_z=-3.76

W5/Q4. Does one calibration remain useful across sessions?

Yes, particularly with Rest-Full. We calibrated once using Session-1 resting EEG and reused the resulting frozen initialization directly for Sessions 2 and 3, recorded one and two weeks later. Within each session, we trained only a linear head using 10% of that session's task labels. The task-only control used the same pretrained backbone without rest calibration and was re-evaluated within each session under identical data splits. We evaluated both multitask decoding and the NBack setting.

Backbone Setting Initialization S1 S2 (+1 week) S3 (+2 weeks)
LaBraM Multitask Task only 27.76 ± 6.42 27.07 ± 6.98 29.18 ± 5.46
LaBraM Multitask Rest-LoRA 31.06 ± 6.86 (+3.30)† 30.65 ± 5.65 (+3.58)† 30.11 ± 4.96 (+0.93)
LaBraM Multitask Rest-Full 31.28 ± 6.73 (+3.52)† 28.89 ± 7.05 (+1.82)† 30.80 ± 5.27 (+1.62)†
LaBraM NBack Task only 41.61 ± 8.24 41.77 ± 8.85 43.82 ± 9.11
LaBraM NBack Rest-LoRA 44.15 ± 8.69 (+2.54)† 43.62 ± 9.28 (+1.85)† 45.42 ± 9.44 (+1.60)†
LaBraM NBack Rest-Full 44.22 ± 8.13 (+2.61)† 42.45 ± 7.35 (+0.68) 45.66 ± 7.63 (+1.84)†
CBraMod Multitask Task only 19.53 ± 2.48 18.97 ± 3.84 19.04 ± 2.68
CBraMod Multitask Rest-LoRA 22.33 ± 4.05 (+2.80)† 18.46 ± 2.00 (−0.51) 18.95 ± 2.28 (−0.09)
CBraMod Multitask Rest-Full 26.00 ± 6.03 (+6.47)† 24.24 ± 6.20 (+5.27)† 25.08 ± 5.08 (+6.04)†
CBraMod NBack Task only 33.89 ± 2.71 34.83 ± 3.74 33.56 ± 2.04
CBraMod NBack Rest-LoRA 35.86 ± 5.51 (+1.97) 35.15 ± 3.11 (+0.32) 34.66 ± 3.39 (+1.10)
CBraMod NBack Rest-Full 46.75 ± 9.47 (+12.86)† 39.89 ± 7.38 (+5.06)† 41.38 ± 6.85 (+7.82)†

Bold indicates a positive mean gain over task-only; † denotes p<0.05, paired t-test across subjects (n=29).

Paired t-tests across the 29 subjects compared each Rest-Tuning initialization with its corresponding task-only control within the same session. Across the eight S2/S3 comparisons, Rest-Full yields positive mean gains in all settings, with seven nominally significant improvements (p=9.20×10−9(p=9.20\times10^{-9} to 0.0361); the remaining LaBraM NBack result at S2 is positive but nonsignificant (+0.68 pp, p=0.463p=0.463). Rest-LoRA is less consistent, yielding positive mean gains in six of eight comparisons and significant positive gains in three. Thus, a single Session-1 calibration remains useful for up to two weeks in the tested setting, with substantially stronger and more consistent evidence for Rest-Full.

W4. Comparison with prior resting-state methods

Rest-Tuning differs from BCM and ResTL primarily in its supervision and reuse regime, rather than merely in the adapted layers. BCM and ResTL operate in task-specific pipelines using multi-subject source rest–task data, whereas Rest-Tuning calibrates a pretrained backbone using only unlabeled resting EEG from the target subject. The resulting calibrated backbone can then be reused across downstream tasks; labeled target-task data is used only during downstream task adaptation.

We also extended the empirical comparison from five subjects to all 29 COGBCI subjects. Because these methods differ in backbone, source supervision, target-label availability, and training protocol, we report the following results as a deployment-regime comparison—not as a label- or architecture-matched superiority claim.

Method Calibration/training data Target-task labels Total time (min) ACC (%)
BCM (EEGNet) 28-subject rest-task pairs + target rest 0% 115.02 39.15±3.62
BCM (EEGConformer) 28-subject rest-task pairs + target rest 0% 122.56 47.15±7.14
ResTL (EEGNet) 28-subject rest-task pairs + target rest 0% 104.50 40.23±3.06
ResTL (EEGConformer) 28-subject rest-task pairs + target rest 0% 60.00 35.49±0.40
Rest-Tuning (LaBraM) Target rest only; rest + task adaptation 10% 4.07 44.42±9.82
Rest-Tuning (BIOT) Target rest only; rest + task adaptation 10% 2.93 78.56±6.12
Rest-Tuning (LaBraM) Target rest only; rest + task adaptation 70% 8.81 78.13±9.45
Rest-Tuning (BIOT) Target rest only; rest + task adaptation 70% 6.16 90.45±3.98

BCM and ResTL require no labeled target-task trials but use multi-subject rest–task data, whereas Rest-Tuning uses only target-subject rest for calibration and subsequently uses the stated fraction of target-task labels for downstream adaptation. Therefore, the accuracy values should not be interpreted as a controlled ranking. Instead, the comparison clarifies the methods’ different data requirements, reuse scope, and adaptation cost. We will make these distinctions explicit and provide the separated calibration/source-training and downstream-adaptation times in the revision.

W1. Limited methodological novelty

We agree that Rest-Tuning introduces no new SSL primitive. It is motivated by a practical gap: task-based calibration is label-intensive and task-specific, while resting EEG is short, unlabeled, and task-independent. Our contribution is the formulation and validation of a post-pretraining, target-rest-only calibration regime: one resting calibration produces a subject-specific backbone before any task is specified, reusable across tasks and adaptation interfaces. Prior per-subject adaptation does not cover this regime. The reusability the reviewer identifies is precisely what we validate: the calibrated backbone remains useful across sessions (Q4) and reduces subject-to-population distance across backbones (Q1). We will revise to set expectations accordingly: the novelty lies in the calibration regime and cross-FM evidence, not in the SSL objective.

W3/Q3. Is the multitask gain an artifact of strided label mapping?

No. The gains persist when the strided global-label mapping is removed and each task is decoded separately. In the manuscript, unitask trains a separate decoder for each task in its original label space and averages accuracy across tasks,and multitask instead trains a single classifier over the disjoint global label space constructed through strided label mapping.

Rest-Tuning yields positive gains under both protocols. We report the LaBraM gains over task-only at the 70% label budget (Table 1), with complete results in Appendix Tables A9–A12.

Calibration + task interface M3CV unitask M3CV multitask COGBCI unitask COGBCI multitask
Rest-LoRA + Task-LoRA +7.38% +5.90% +3.07% +4.47%
Rest-Full + Task-Full +6.67% +3.84% +2.94% +4.69%

Thus, improvement is also present when tasks are decoded separately; it is not created by the global-label construction.

W6/Q2. Saturation analysis is backbone-specific.

We extended the 30–210 s duration analysis to LaBraM Rest-LoRA and CBraMod Rest-Full under task-label budgets from 1% to 10%. Each value below is mean ACC (%) averaged across the ten budgets.

Setting 30 s 60 s 90 s 120 s 150s 180 s 210 s
LaBraM Rest-Full 34.80 35.01 35.13 35.59 35.11 35.22 35.42
LaBraM Rest-LoRA 34.29 34.36 34.06 34.10 33.82 33.99 33.85
CBraMod Rest-Full 43.27 43.33 43.01 43.31 43.19 43.27 43.05

Within 60–120 s, mean ACC varies by only 0.58, 0.30, and 0.32 pp, respectively. All three configurations attain their highest mean ACC within this window, and none of the 150–210 s durations exceeds the corresponding in-window maximum. Despite different downstream gains, their similar plateau timing provides no evidence that saturation time scales with gain magnitude.

Q5. Why use a frozen rather than momentum-updated teacher?

The frozen teacher provides a fixed population anchor while the student adapts to the 1–3 minutes of target-subject data. A momentum teacher would absorb the same target-specific updates and alter this anchoring mechanism. We will clarify this design choice in the manuscript; momentum updating is a possible extension rather than a requirement of the current method.

Limitations and scope revisions

We will revise the manuscript to make four limitations explicit. First, robustness to EEG artifacts has not been systematically evaluated. Second, the cross-session pilot was conducted using the same dataset, montage, and acquisition protocol. It therefore does not establish robustness across devices or electrode repositioning. Third, evaluation on four FMs does not establish generalization to all tokenization schemes or clinical populations. Fourth, in a single-task deployment, the one-time Rest-Tuning cost cannot be amortized across multiple downstream tasks.

Reviewer 4uPN · CommentOpenReview ↗

Thank you for providing point-by-point response to my questions and concerns, and performing new analyses and experiments.

  • W2/Q1. Does representation alignment generalize beyond LaBraM? Thank you for doing this generalization analysis across backbones and datasets.This is a real improvement over the original reported results. However, this is done over only 2 of 4 backbones and no statistical significance test is reported for these deltas.

  • W5/Q4. Does one calibration remain useful across sessions? Well addressed, thank you!

  • W4. Comparison with prior resting-state methods Expanded from 5 to 29 subjects, which is great. However, as acknowledged, it is difficult to claim a strong relative advantage over other methods.

  • W1. Limited methodological novelty This is a reframing of contribution, which is an acceptable response, but doesn't change the limited novelty assessment. The originality score 2 stands.

  • W3/Q3. Is the multitask gain an artifact of strided label mapping? Thank you, this directly answers the question. No further comment/question on this.

  • W6/Q2. Saturation analysis is backbone-specific. Reasonable and satisfactory answer. However, EEGPT and BIOT are missing.

  • Q5. Why use a frozen rather than momentum-updated teacher? Thanks for the clarification. No further question on this.

I appreciate all the efforts that the authors have put into running additional generalization and comparison analysis. However, there is limited methodological novelty and the original rating stands.

Authors · CommentOpenReview ↗

Thank you for the careful follow-up and for recognizing that the added generalization and comparison analyses strengthen the paper. In this final response, we provide two experimental updates addressing the remaining empirical points you identified — the cross-backbone alignment analysis (now extended to BIOT) and the saturation analysis (now extended to EEGPT and BIOT, covering all four backbones) — and then clarify the method-level originality of Rest-Tuning.

Additional evidence on cross-backbone representation alignment

We would first like to clarify that the previously reported alignment analyses did include paired subject-level significance tests and paired Cohen's dzd_z: CBraMod–COGBCI (p=1.19×10−18p=1.19\times10^{-18}, dz=−3.89d_z=-3.89), LaBraM–COGBCI (p=9.07×10−13p=9.07\times10^{-13}, dz=−2.28d_z=-2.28), and LaBraM–M3CV (p=3.03×10−18p=3.03\times10^{-18}, dz=−3.76d_z=-3.76). We apologize if the table formatting made these tests easy to overlook.

We have now additionally completed the analysis for BIOT on COGBCI: Rest-Tuning reduces the Wasserstein distance from 163.04±6.53163.04 \pm 6.53 to 92.47±2.8692.47 \pm 2.86, with p=7.41×10−11p=7.41\times10^{-11} and paired Cohen's dz=−1.88d_z=-1.88. The alignment analysis therefore shows statistically significant paired reductions across three of the four evaluated backbones and both datasets.

Completing the corresponding EEGPT analysis would require 29 additional subject-excluded continued-pretraining runs, amounting to approximately 1,900 GPU-hours, and was therefore infeasible within the discussion period. We will state this remaining coverage limitation explicitly.

Additional evidence on saturation

We also extended the 30–210s duration analysis to both EEGPT and BIOT calibration interfaces:

Setting 30s 60s 90s 120s 150s 180s 210s
EEGPT Rest-Full 50.92 51.30 51.18 51.20 51.06 51.37 51.23
EEGPT Rest-LoRA 50.98 51.73 51.67 51.89 51.63 51.52 51.67
BIOT Rest-Full 65.26 65.66 65.55 65.54 65.80 65.58 64.97
BIOT Rest-LoRA 64.36 64.51 64.37 64.46 64.48 64.25 63.91

Across both EEGPT and BIOT, performance stabilizes after approximately 60–120 seconds and changes only marginally with additional resting data. Together with the previously reported LaBraM and CBraMod results, the duration analysis now covers all four backbones and consistently supports our original practical conclusion: 1–3 minutes of resting EEG are sufficient for effective subject calibration in the tested settings.

Clarification of method-level originality

We agree that the individual SSL primitives are established. However, characterizing Rest-Tuning as standard SSL applied per subject does not fully capture its distinct optimization target and protocol-specific construction. Rest-Tuning performs post-pretraining, pre-task, target-rest-only calibration: using only 1–3 minutes of unlabeled rest from a new subject, before any downstream task or labels are available, to produce a subject-specific FM initialization reusable across tasks, adaptation interfaces, and later sessions. This differs from population-level SSL and from BCM/ResTL-style task-specific transfer using rest–task information.

This regime motivates the specific construction: the frozen teacher preserves the population prior under extremely limited target data; masked-student/intact-teacher asymmetry prevents near-trivial matching between identically initialized branches; InfoNCE maintains relative inter-window discrimination; and MSE provides negative-free anchoring when temporally correlated rest windows may act as imperfect negatives.

This is not only a conceptual distinction. The loss-term ablation (Reviewer 7cAz, W3) shows that the complete InfoNCE–MSE objective performs best and that removing the terms causes the predicted degradations. Under identical target-rest data, calibration parameterization, and downstream interfaces, Rest-Tuning also significantly outperforms a matched MAE calibration baseline by 2.36 pp with LoRA and 5.96 pp with full tuning (see our follow-up response to Reviewer 7cAz). These results show that the gains cannot be explained solely by additional masked self-supervised calibration. Its cross-task and cross-session reuse (W3/Q3 and W5/Q4 above) further validates the intended optimization output—a reusable subject-specific initialization rather than a representation optimized only for the calibration data or a task-specific solution.

Thus, although the constituent primitives are established, Rest-Tuning is not reducible to an off-the-shelf SSL recipe. Its method-level originality lies in the prior-preserving calibration construction tailored to short, correlated target-subject EEG and in the post-pretraining calibrate-once-and-reuse problem that this construction realizes.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?