potentialpaper

Less Evidence, Better Answering: Gain-Aware Minimal Evidence Subset Selection for Medical QA

Songyue Guo, Zhao CHEN, Caleb Chen Cao, Lei Chen

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. MEGA improves evidence-grounded medical question answering by selecting compact, high-utility supporting evidence through hidden-state information gain, achieving better answer quality and evidence grounding with fewer evidence tokens.

Abstract. Evidence-grounded medical question answering requires not only accurate answers, but also precise, verifiable, and clinically trustworthy evidence. Existing medical RAG systems typically retrieve top-kk chunks according to item-wise relevance. Although this design improves recall, it does not explicitly optimize whether the selected evidence set is compact, sufficient, and decision-critical. In this paper, we study medical evidence-grounded QA from a different perspective: instead of retrieving evidence without optimization, the evidence-grounded medical QA system should identify a compact sufficient subset of high-density evidence snippets. We propose MEGA, a gain-aware framework for compact supporting medical evidence selection. MEGA first expands clinical queries into complementary subqueries and performs hybrid retrieval to construct a recall-oriented candidate evidence pool. It then introduces hidden-state Information Gain Scoring, which uses a frozen LLM to estimate whether each candidate snippet contributes new answer-relevant information beyond surface relevance. Finally, MEGA formulates evidence selection as a budgeted utility maximization problem and proposes an FPTAS selector to identify a compact evidence subset under an explicit token budget. We further construct two evidence-grounded medical QA benchmarks, CRC-EvidenceQA and Med-EvidenceQA, to evaluate both answer quality and evidence grounding. Across three LLM backbones and five medical RAG baselines, MEGA consistently achieves the best results, improving over the second-best baseline by 8.8%8.8\% on average in answer quality and 38.8% on average in evidence F1. Ablation studies and blinded clinical expert evaluation further validate its robustness and clinical relevance.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
2 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:45 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

Summary:
This paper proposes MEGA, a medical question answering framework that selects compact and decision relevant evidence rather than retaining independently ranked top k passages. The framework combines subquery based hybrid retrieval, hidden state Information Gain Scoring, and an FPTAS selector that optimizes evidence utility under a token budget, while also introducing CRC-EvidenceQA and Med-EvidenceQA for evaluating answer quality and evidence grounding. Experiments across three language model backbones and five medical RAG baselines report substantial improvements in answer quality and Evidence F1 with fewer evidence tokens, supported by ablation studies and clinician evaluation.

Strengths:
Reviewers 1JmM, q6S3, and RrbL agree that the paper addresses an important and clearly motivated problem in high stakes medical question answering through a novel shift from passage ranking to compact evidence subset optimization. They also recognize the clear presentation, comprehensive technical pipeline, strong empirical results across multiple models and datasets, detailed ablations, and inclusion of clinician based evaluation.

Weaknesses:
Reviewers 1JmM, q6S3, and RrbL question whether the hidden state information gain signals generalize across different frozen models, architectures, middle layer choices, and judge models. Reviewers 1JmM and q6S3 highlight that the considerable inference latency and hardware requirements weaken the claimed efficiency benefits and leave practical clinical integration insufficiently addressed. Reviewer q6S3 notes that the cross layer coherence and gradient signals appear heuristic, provide relatively limited gains, and lack sufficient theoretical or architecture independent validation. Reviewers q6S3 and RrbL request stronger analysis of the selection mechanism, including comparisons with greedy selection using identical IGS scores, sensitivity under tighter token budgets, clearer Evidence F1 definitions, and more informative qualitative success and failure cases.

Response Direction:
A convincing response should demonstrate robustness across scorer and judge families, provide latency and deployment analyses, justify each IGS component, and add controlled greedy, budget sensitivity, metric clarification, and qualitative failure case evaluations.


The authors substantially addressed the flagged technical concerns through new robustness tests, budget-matched and greedy-selector comparisons, latency and deployment clarifications, and failure-case analysis; in discussion, RrbL found the clarifications satisfactory, q6S3 raised the rating from 3 to 4 while retaining concerns about the paper’s framing, and 1JmM provided no further feedback.

I recommend a borderline accept because the paper presents a well-motivated and technically solid approach to compact evidence subset selection, supported by strong multi-model, multi-dataset, ablation, and clinician evaluations, while the remaining concerns about the “less evidence” framing, inference latency, and clinical deployment temper rather than outweigh its contributions.

Final justification

Taking the reviews, author response, and discussion together, I recommend borderline accept, as the additional evidence resolves most technical concerns and leaves the reasons for acceptance narrowly stronger than the remaining limitations.

Area Chair 52tN · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

Summary:
This paper proposes MEGA, a medical question answering framework that selects compact and decision relevant evidence rather than retaining independently ranked top k passages. The framework combines subquery based hybrid retrieval, hidden state Information Gain Scoring, and an FPTAS selector that optimizes evidence utility under a token budget, while also introducing CRC-EvidenceQA and Med-EvidenceQA for evaluating answer quality and evidence grounding. Experiments across three language model backbones and five medical RAG baselines report substantial improvements in answer quality and Evidence F1 with fewer evidence tokens, supported by ablation studies and clinician evaluation.

Strengths:
Reviewers 1JmM, q6S3, and RrbL agree that the paper addresses an important and clearly motivated problem in high stakes medical question answering through a novel shift from passage ranking to compact evidence subset optimization. They also recognize the clear presentation, comprehensive technical pipeline, strong empirical results across multiple models and datasets, detailed ablations, and inclusion of clinician based evaluation.

Weaknesses:
Reviewers 1JmM, q6S3, and RrbL question whether the hidden state information gain signals generalize across different frozen models, architectures, middle layer choices, and judge models. Reviewers 1JmM and q6S3 highlight that the considerable inference latency and hardware requirements weaken the claimed efficiency benefits and leave practical clinical integration insufficiently addressed. Reviewer q6S3 notes that the cross layer coherence and gradient signals appear heuristic, provide relatively limited gains, and lack sufficient theoretical or architecture independent validation. Reviewers q6S3 and RrbL request stronger analysis of the selection mechanism, including comparisons with greedy selection using identical IGS scores, sensitivity under tighter token budgets, clearer Evidence F1 definitions, and more informative qualitative success and failure cases.

Response Direction:
A convincing response should demonstrate robustness across scorer and judge families, provide latency and deployment analyses, justify each IGS component, and add controlled greedy, budget sensitivity, metric clarification, and qualitative failure case evaluations.


The authors substantially addressed the flagged technical concerns through new robustness tests, budget-matched and greedy-selector comparisons, latency and deployment clarifications, and failure-case analysis; in discussion, RrbL found the clarifications satisfactory, q6S3 raised the rating from 3 to 4 while retaining concerns about the paper’s framing, and 1JmM provided no further feedback.

I recommend a borderline accept because the paper presents a well-motivated and technically solid approach to compact evidence subset selection, supported by strong multi-model, multi-dataset, ablation, and clinician evaluations, while the remaining concerns about the “less evidence” framing, inference latency, and clinical deployment temper rather than outweigh its contributions.

Final justification

Taking the reviews, author response, and discussion together, I recommend borderline accept, as the additional evidence resolves most technical concerns and leaves the reasons for acceptance narrowly stronger than the remaining limitations.

1 comment
Authors · CommentOpenReview ↗

Rebuttal Summary for the Initial Meta Review

Dear Reviewers and AC,

We sincerely appreciate your time and effort in reviewing our paper. The reviewers consistently recognize that MEGA addresses an important problem in medical RAG, is clearly presented, and introduces a novel shift from top-kk ranking to compact evidence subset optimization. We conducted additional experiments and analyses addressing all major concerns.

  1. Robustness of IGS (Reviewer 1JmM, q6S3, and RrbL). The default middle-layer range [L/4,3L/4][L/4,3L/4] achieves the best KP-AUROC, Spearman correlation, answer quality, and Evidence F1. IGS is also effective consistently across different LLM families and structures: Qwen, Llama, and Mistral. Re-evaluation with different judge LLMs: GPT-5.1, DeepSeek-V4-Flash, and Gemini-3.6-Flash changes judge-dependent metrics by at most 0.030.03. Thus, the conclusions are not tied to a specific scorer architecture, or judge LLM.

  2. Latency and deployment scope (Reviewer 1JmM and q6S3). The reported 32.032.0 s is full-response latency, while time to first token (TTFT) is about 17.317.3 s,comparable to the reported 14.15±2.9114.15\pm2.91 s response-initiation time of OpenEvidence under streaming. The four-A800 setup was used for evaluation throughput rather than being a deployment requirement; single-query Qwen3-8B scoring runs on one A800. We will explicitly describe MEGA as improving evidence-token efficiency, acknowledge its additional latency, and position it for non-emergency evidence review rather than latency-critical care.

  3. Interpretation of IGS components (Reviewer q6S3). IGS is an evidence-utility estimator under imperfect retrieval, not a factual verification module. Cross-Layer Coherence and Gradient are not arbitrary heuristics, but theory-motivated geometric statistics describing evidence-induced representation trajectories, which are geometric proxies for persistent and depth-increasing representation updates. Individually, they achieve key-point AUROC of 0.74/0.760.74/0.76 and Spearman correlation of 0.58/0.600.58/0.60, exceeding the reranker’s 0.60/0.420.60/0.42. Their smaller drop-one ablation gains reflect overlap with the other IGS signals. They require no additional LLM forward passes, so their post-processing overhead is negligible.

  4. Budget and selector analysis (Reviewer q6S3 and RrbL). Performance shows a sufficiency transition around B=512B=512–768768 and saturates beyond approximately B=1024B=1024. MEGA remains strongest under tight matched budgets of 256256 and 512512 tokens. Using identical IGS scores, FPTAS improves over Greedy-Density by 2.02.0 Evidence-F1 points and 0.090.09 answer-quality points, selects fewer tokens, and adds only about 11 ms. Additional ablation confirms that the hard budget guarantees the maximum context length, while the soft penalties encourage compactness within that feasible space. Therefore, they are complementary rather than redundant.

  5. Evaluation clarity and failure analysis (Reviewer 1JmM and q6S3). Evidence F1 is computed identically for all methods from evidence cited in the final answer; Context+LLM’s full input context is not treated as selected evidence. Qualitative inspection identifies candidate-recall failures as the dominant failure mode, followed by IGS near-miss misranking. We will add representative success/failure cases, clarify the relationship to Information Bottleneck and Information Pursuit, move critical evaluation details into the revised version, and improve the readability of Figures 3-4.

Overall, the rebuttal with additional results and analysis directly responds to all the meta-review concerns. The main gains remain consistent across scorer families, judges, token budgets, and selector variants. We provide a clear analysis of latency and deployment to demonstrate that the latency of our method is acceptable, and to illustrate that our IGS module is theory-motivated; its introduction ensures improved IGS stability while incurring minimal computational overhead. Furthermore, we conduct experimental analyses of budget sensitivity, demonstrate the effective improvement of FPTAS over the Greedy algorithm, and perform a qualitative analysis of successful and failed cases.

Once again, we appreciate your constructive feedback and encouragement, which have significantly improved our paper.

Sincerely,

Submission 13920 Authors

Reviewer RrbLOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
4/4
Clarity
4/4
Significance
4/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This work addresses the central challenge of redundancy and noise in medical retrieval-augmented generation (RAG), where standard top-k retrieval often fails to provide a compact, decision-critical evidence set. The authors propose MEGA, a framework that transforms evidence retrieval into a budgeted subset selection problem. MEGA employs sub-query expansion for recall, an Information Gain Scoring (IGS) mechanism using frozen LLM hidden states to estimate evidence utility, and a Fully Polynomial-Time Approximation Scheme (FPTAS) to optimize the evidence subset under a token budget. The claims of the paper are that this gain-aware selection improves both answer quality and evidence grounding while reducing token overhead. Evaluation on the new CRC-EvidenceQA and Med-EvidenceQA benchmarks across multiple LLM backbones shows significant improvements in Evidence F1 and answer metrics compared to five RAG baselines.

Strengths and weaknesses

I found this to be a well written paper that addresses a well defined problem in an intelligent and rigorous manner. It was probably the most well written paper I reviewed for this year's conference.

Questions
  1. The IGS mechanism relies on hidden states of a frozen LLM to estimate utility. How sensitive is the performance to the choice of the 'middle layers' or the specific frozen model used, and does the information gain signal generalize across different model architectures or is it tightly coupled to the scoring model's internal representations?
  2. The token budget B is tuned on a development split. Since B is a critical hyperparameter for the compactness claim, how does the performance vary across different budget constraints? Specifically, is there a threshold where reducing the budget significantly degrades answer quality, and how does MEGA's Pareto frontier compare to baselines when the budget is extremely tight?
  3. The paper compares MEGA against several RAG baselines, but does not explicitly compare the FPTAS selector against a simple greedy selection based on the same IGS scores. Could the authors provide a comparison between Greedy(IGS) and FPTAS(IGS) to clarify if the optimization complexity is providing the observed gains over a simpler heuristic?
Limitations

Yes

Final justification

I thought this was a well written paper on a topic of high importance to medicine. The authors have improved their manuscript through the review process.

Formatting concerns

I have no

4 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely thank Reviewer RrbL for the time and care devoted to evaluating our work. We greatly appreciate your encouraging assessment of the paper’s quality and clarity, and your recognition that it addresses a well-defined problem rigorously. We provide additional experiments and clarifications below.


Q1: How sensitive is the performance to the choice of the 'middle layers' or the specific frozen model used, and does the information gain signal generalize across different model architectures or is it tightly coupled to the scoring model's internal representations?

A1: We conducted two additional experiments on (1) sensitivity to the middle-layer range and (2) robustness across frozen scorers from different families and scales.

Following Appendix E.3.1, we use 100 CRC-EvidenceQA and 200 Med-EvidenceQA examples (100 PubMedQA and 100 COVID-QA). GPT-5.1 is the judge, and all other settings remain fixed.

Sensitivity to the choice of the middle layers. We partition normalized model depth into four equal-width regions and additionally test the default middle half, [L/4,3L/4][L/4,3L/4]. For the quarter-depth settings, we uniformly sample the same number of layers. Only the IGS layer set changes; the scorer, answer backbone, retrieval results, selector hyperparameters, prompts, and random seeds remain fixed.

Table 1. Sensitivity to the hidden-layer region used by IGS.

Scoring region KP-AUROC ↑\uparrow KP-Spearman ρ↑\rho\uparrow Ans. Quality ↑\uparrow Evi. F1 (%) ↑\uparrow
Early [0,14][0,\frac14] 0.54 0.35 7.96 68.9
Lower-middle [14,12][\frac14,\frac12] 0.68 0.55 8.39 78.6
Upper-middle [12,34][\frac12,\frac34] 0.72 0.59 8.53 81.2
Late [34,1][\frac34,1] 0.57 0.38 8.08 70.7
Middle-half [14,34][\frac14,\frac34], default 0.77 0.66 8.74 84.6

The middle regions clearly outperform the early and late regions, and the default middle-half setting performs best on all metrics. Compared with the strongest individual region, it improves KP-AUROC by 0.05, Spearman correlation by 0.07, answer quality by 0.21, and Evidence F1 by 3.4 points. Early layers mainly encode lexical and local contextual features, while late layers are more oriented toward next-token prediction and response realization. Middle layers better capture query–evidence integration. Aggregating the broader middle half also allows cross-layer coherence and information-gradient signals to model a more stable evidence-integration trajectory. These results support [L/4,3L/4][L/4,3L/4] as a principled default.

Table 2. Robustness to the frozen scorer model.

Frozen scorer Params kp-AUROC kp-Spearman Ans. Quality Evi. F1 Time
Qwen3-8B 8B 0.77 0.66 8.74 84.6 1.0$\times$
Qwen3-4B 4B 0.57 0.54 6.38 66.4 0.7$\times$
Qwen3-32B 32B 0.79 0.68 8.80 85.1 3.7$\times$
Llama-3.1-8B-Instruct 8B 0.75 0.66 8.69 83.9 1.1$\times$
Mistral-7B-v0.1 7B 0.74 0.63 8.52 83.2 0.9$\times$

The signal transfers consistently across Qwen, Llama, and Mistral. The two non-Qwen scorers remain within 1.6 Evidence-F1 points and 0.22 answer-quality points of Qwen3-8B. Increasing Qwen from 8B to 32B yields only +0.5 Evidence F1 and +0.06 answer quality, but costs 3.7$\times$ more runtime. The 4B scorer is substantially weaker, indicating that very small scorers produce noisier utility estimates. Overall, IGS is not tightly coupled to a particular architecture, although smaller models may require calibration.


Q2: The token budget B is tuned on a development split. Since B is a critical hyperparameter for the compactness claim, how does the performance vary across different budget constraints? Specifically, is there a threshold where reducing the budget significantly degrades answer quality, and how does MEGA's Pareto frontier compare to baselines when the budget is extremely tight?

A2: We sweep BB using the same 300 examples as Q1, while fixing the candidate pool, IGS scorer, answer model, and all other hyperparameters.

Table 3. Sensitivity to the evidence-token budget BB.

Budget BB Avg. selected tokens Ans. Quality ↑\uparrow Evi. F1 (%) ↑\uparrow
256 239 7.74 65.7
384 361 8.17 74.6
512 476 8.48 80.9
768 598 8.69 83.8
1024 608 8.73 84.4
1536 611 8.74 84.5

A clear transition occurs around B=512B=512--768768. Below this range, the budget excludes clinically necessary evidence, sharply reducing evidence recall and answer quality. Beyond B≈1024B\approx1024, performance saturates. This is because BB is an upper bound rather than a target: the selector need not fill the context, and non-positive-utility candidates are discarded before optimization. Thus, larger budgets do not force noisy evidence into the selected set.

For a controlled Pareto comparison, we impose the same hard budget on all methods. Baselines without an explicit budget mechanism retain passages in their original ranking order until the next passage would exceed BB.

Table 4. Budget-matched comparison under extremely tight budgets.

Method Quality @256 ↑\uparrow Evi. F1 @256 ↑\uparrow Quality @512 ↑\uparrow Evi. F1 @512 ↑\uparrow
Reranker-TopBudget 7.18 52.8 7.84 64.6
DoctorRAG-TopBudget 7.36 57.4 8.01 68.9
Greedy$_{\mathrm{IGS}}$ 7.55 62.8 8.31 77.4
MEGA 7.74 65.7 8.48 80.9

MEGA maintains the strongest quality–budget trade-off under both tight settings. The advantage is largest at B=256B=256, where an independently ranked long or redundant snippet can consume most of the available budget.


Q3: The paper compares MEGA against several RAG baselines, but does not explicitly compare the FPTAS selector against a simple greedy selection based on the same IGS scores. Could the authors provide a comparison between Greedy(IGS) and FPTAS(IGS) to clarify if the optimization complexity is providing the observed gains over a simpler heuristic?

A3: We add two greedy variants with the same candidate pool and IGS utilities. Greedy-Value sorts by viv_i, while Greedy-Density sorts by vi/tiv_i/t_i. All other components remain fixed. The surrogate gap is measured against the exact 0/1-knapsack optimum.

Table 5. Comparison of selectors using the same IGS utilities.

Selector Surrogate gap ↓\downarrow Ans. Quality ↑\uparrow Evi. F1 (%) ↑\uparrow Tokens ↓\downarrow Solver time
Greedy-Value 8.7% 8.57 81.0 705 0.06 ms
Greedy-Density 4.2% 8.65 82.6 664 0.09 ms
FPTAS, ϵ=0.1\epsilon=0.1 0.9% 8.74 84.6 612 1.0 ms

FPTAS improves over the stronger Greedy-Density variant by +2.0 Evidence-F1 points and +0.09 answer quality while selecting fewer tokens. Greedy selection makes irreversible local choices and can be suboptimal when snippets have heterogeneous token costs; one long, high-valued snippet may block several shorter snippets with greater combined utility. It also provides no (1−ϵ)(1-\epsilon) guarantee for 0/1 knapsack. In contrast, the value-scaled FPTAS globally considers feasible utility–cost combinations and guarantees at least (1−ϵ)(1-\epsilon) of the optimal surrogate utility.

The end-to-end gains show that more accurately optimizing the surrogate improves evidence grounding and answer quality. The additional solver cost is only about 1 ms per query, negligible relative to hidden-state scoring and answer generation.


Thanks again for your comments. If you have any additional concerns or suggestions, please feel free to share them, and we sincerely value your feedback.

Authors · CommentOpenReview ↗

Kind Reminder of the Discussion Period Ending Soon

Dear Reviewer,

I hope this message finds you well. As the discussion period is nearing its end with less than two days remaining, I wanted to ensure we have addressed all your concerns satisfactorily. If there are any additional points or feedback you'd like us to consider, please let us know. Your insights are invaluable to us, and we're eager to address any remaining issues to improve our work.

Thank you for your time and effort in reviewing our paper.

Reviewer RrbL · CommentOpenReview ↗

Response to comments

Thanks for your clarifying responses to my review.

Authors · CommentOpenReview ↗

Dear Reviewer RrbL,

Thank you very much for your thoughtful feedback and for carefully considering our rebuttal. We sincerely appreciate your recognition of our additional analyses and clarifications, and we are grateful that our responses helped address your concerns.

Your valuable comments have greatly helped us improve the paper. Thank you again for your time, encouragement, and constructive suggestions.

Sincerely,

Reviewer q6S3OpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper addresses the limitations of RAG in medical question answering (QA), where traditional top-k retrieval often yields redundant, partially relevant, or non-critical context. To overcome this, the authors introduce MEGA, a framework that reformulates evidence retrieval as a budgeted minimal sufficient evidence selection problem.

The MEGA framework operates through three primary components: 1.Subquery Generation and Hybrid Retrieval: Decomposing complex clinical queries to build a comprehensive, recall-oriented candidate evidence pool. 2.Information Gain Scoring (IGS): Utilizing the internal hidden states of a frozen Large Language Model (LLM) to measure whether a candidate snippet contributes novel, decision-critical information, rather than merely sharing surface-level relevance with the query. 3.FPTAS Evidence Selector: Framing the final subset selection as an NP-hard 0/1 knapsack optimization problem and employing a Fully Polynomial-Time Approximation Scheme (FPTAS) to select a compact, high-utility evidence subset under a strict token budget.

As a other contribution to the field, the authors also construct two new evidence-grounded benchmarks: a clinician-curated colorectal cancer dataset (CRC-EvidenceQA) and an open-data biomedical dataset (Med-EvidenceQA). Through extensive experiments, the paper demonstrates that MEGA consistently outperforms existing medical RAG baselines across different LLM backbones. It achieves significant improvements in both final answer quality and evidence grounding (measured by Evidence F1) while substantially reducing the total number of evidence tokens passed to the generator.

Strengths and weaknesses

1. Quality

The overall technical design of the paper is comprehensive but exhibits the following shortcomings in methodological rigor, experimental objectivity, and engineering practicality, which require the author's focused response:

a.The IGS algorithm heavily relies on the magnitude of shifts in hidden layer states (e.g., representation drift and cosine shifts). However, in medical contexts, retrieving "wrong conclusions" that strongly contradict the current context (e.g., mistaking contraindications for indications) can similarly induce significant internal state oscillations. The framework currently lacks a mechanism to distinguish between "high-value correct gains" and "high-noise disruptive errors," revealing a flawed assumption. b. The main text highlights that MEGA reduces tokens by 35.6% to improve "efficiency." However, Appendix E.3.2 reveals that when computing IGS with Qwen3-8B, each query takes an average of 32.0 seconds. The paper should discuss the tradeoff between token reduction and time inefficiency. c. The concepts of Cross-Layer Coherence and Cross-Layer Gradients are not adequately supported by theory or experimentation. The authors should clarify whether these are purely heuristic designs. More importantly, ablation studies reveal that their actual performance contribution is negligible while introducing substantial computational overhead. This raises questions about their practical value. Furthermore, the robustness of these signals remains unproven in architectures beyond Qwen. d. While Equation (1) introduces a penalty term, to dynamically regulate evidence length and approximate a minimum sufficient set, the FPTAS algorithm still depends on a "hard threshold upper limit B" manually fine-tuned on the validation set. This dual constraint appears redundant, leaving ambiguity about which component plays the primary role.

2. Clarity

The overall structure of the paper is clear and well-written, but there are ambiguities in detailing critical evaluation metrics and visual presentation of results:

a. The explanation and comparison of Evidence F1 are insufficiently clear in the main body. For example, MEGA’s ev-F1 and the ev-F1 of Context+LLM differ in their calculation, yet they are presented in the same table without explicit clarification, which can mislead readers. Many critical evaluation details are relegated to the appendix. b. In Figure 3, the numerical labels and error bars are heavily overlapping, while in Figure 4, data points are also cluttered. Both issues undermine the intuitive communication of insights from the data.

3. Significance

The clinical motivation of the paper is compelling. In medical evidence-based Q&A contexts, evidence accuracy and traceability (traceability to reliable sources) are equally critical.

4. Originality

The study presents innovative methodology, breaking away from the conventional reliance on traditional cross-encoder calculations of external relevance in medical RAG tasks. It proposes a novel approach that leverages frozen LLM intermediate layer hidden states to quantify information gain and combines this with an FPTAS algorithm to solve a knapsack problem. However, as mentioned under the "Quality" dimension, the use of intermediate-layer features currently leans heavily towards "heuristic engineering design" and lacks a solid theoretical framework.

Questions

a.The IGS algorithm heavily relies on the magnitude of shifts in hidden layer states (e.g., representation drift and cosine shifts). However, in medical contexts, retrieving "wrong conclusions" that strongly contradict the current context (e.g., mistaking contraindications for indications) can similarly induce significant internal state oscillations. The framework currently lacks a mechanism to distinguish between "high-value correct gains" and "high-noise disruptive errors," revealing a flawed assumption. b. The main text highlights that MEGA reduces tokens by 35.6% to improve "efficiency." However, Appendix E.3.2 reveals that when computing IGS with Qwen3-8B, each query takes an average of 32.0 seconds. The paper should discuss the tradeoff between token reduction and time inefficiency. c. The concepts of Cross-Layer Coherence and Cross-Layer Gradients are not adequately supported by theory or experimentation. The authors should clarify whether these are purely heuristic designs. More importantly, ablation studies reveal that their actual performance contribution is negligible while introducing substantial computational overhead. This raises questions about their practical value. Furthermore, the robustness of these signals remains unproven in architectures beyond Qwen. d. While Equation (1) introduces a penalty term, to dynamically regulate evidence length and approximate a minimum sufficient set, the FPTAS algorithm still depends on a "hard threshold upper limit B" manually fine-tuned on the validation set. This dual constraint appears redundant, leaving ambiguity about which component plays the primary role. e. The explanation and comparison of Evidence F1 are insufficiently clear in the main body. For example, MEGA’s ev-F1 and the ev-F1 of Context+LLM differ in their calculation, yet they are presented in the same table without explicit clarification, which can mislead readers. Many critical evaluation details are relegated to the appendix. f. In Figure 3, the numerical labels and error bars are heavily overlapping, while in Figure 4, data points are also cluttered. Both issues undermine the intuitive communication of insights from the data.

Limitations

The main text highlights that MEGA reduces tokens by 35.6% to improve "efficiency." However, Appendix E.3.2 reveals that when computing IGS with Qwen3-8B, each query takes an average of 32.0 seconds. The paper should discuss the tradeoff between token reduction and time inefficiency.

Final justification

I have carefully read the authors’ response, and overall, it has addressed some of my concerns. This is a thoughtfully written and professionally presented paper, and the proposed approach appears to be effective. However, I find the title and the paper’s overall narrative substantially misleading.

For example, the ablation results suggest that the improvement in QA performance is primarily attributable to the sub-question expansion and hybrid retrieval module, which increases the diversity of the retrieved evidence, rather than to using less evidence. The paper does employ evaluation and selection mechanisms to reduce ineffective evidence tokens as much as possible, but this is not equivalent to claiming that “less evidence leads to better answers.”

For RAG-based QA systems, the objective at the evidence level has always been to retrieve a complementary, diverse, and effective set of evidence that adequately supports the answer, while minimizing irrelevant, ineffective, and redundant evidence. This objective has not changed, and it does not imply that less evidence is inherently better.

A catchy title may help attract attention and increase the paper’s visibility, but an inaccurate claim can also propagate misconceptions and mislead other researchers, particularly in today’s increasingly attention-driven academic environment.

Overall, I believe the most appropriate rating would be 3.5. Since this option is not available, I have temporarily raised my initial rating to 4. I leave the final assessment to the AC and SAC for their comprehensive consideration.

Formatting concerns

None

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Dear Reviewer q6S3,

Thank you for your detailed and constructive feedback. Below, we respond to each comment.


Q1: Large hidden-state shifts may also be caused by misleading or contradictory medical evidence. How does IGS distinguish useful information gain from disruptive noise rather than assuming that larger shifts imply higher utility?

A1: We thank the reviewer for raising this important point. We agree that a large hidden-state shift alone cannot guarantee factual correctness. However, this is not the assumption of IGS. As stated in Sec. 3.2, Line 158, IGS is an evidence-utility estimator under imperfect retrieval, not a factual verification module.

Let the candidate pool be C=C+∪C−C=C^+\cup C^-, where C+C^+ and C−C^- denote supporting and misleading evidence, respectively. Since no retriever, reranker, or LLM filter can remove all noise, ϵR=P(c∈C−∣c∈C)>0\epsilon_R=P(c\in C^-\mid c\in C)>0. Therefore, the goal of IGS is not to achieve zero error but to avoid noise amplifying noise: ϵS=P(c∈C−∣c∈S)≤ϵR\epsilon_S=P(c\in C^-\mid c\in S)\leq\epsilon_R.

Under the weak assumption P(s(c)>τ∣c∈C+)≥P(s(c)>τ∣c∈C−)P(s(c)>\tau\mid c\in C^+)\geq P(s(c)>\tau\mid c\in C^-), IGS reduces the expected noise proportion after scoring. Figure 3 empirically supports this assumption. Although the reranker is slightly better on general relevance, IGS aligns substantially better with key-point coverage, indicating that it captures answer-relevant utility beyond surface relevance.


Q2 & L1: Discuss the tradeoff between token reduction and time inefficiency.

A2: The 32.0s reported in Appendix E.3.2 is end-to-end latency, not IGS-only cost. Stage-wise profiling gives 2.9s for retrieval, 14.4s for IGS, 0.008s for FPTAS, and 14.7s for answer generation, yielding approximately 30–32s total latency and 17.3s TTFT. OpenEvidence reports approximately 14.15±2.91s response initiation. Thus, streaming of MEGA can provide comparable user-perceived responsiveness.

Table 1. Stage-wise latency of MEGA.

Stage Average latency
Hybrid retrieval 2.9 s
IGS computation 14.4 s
FPTAS selection 0.008 s
Answer generation 14.7 s
Time to first token 17.3 s
Full-response latency 32.0 s

Moreover, MEGA trades 14.4s of scoring overhead for 35.6% fewer evidence tokens and substantially stronger evidence grounding. We agree that token efficiency does not imply latency efficiency. We will replace “efficiency” with evidence-token efficiency, report the latency decomposition, and clarify that MEGA targets non-emergency evidence review rather than latency-critical applications.


Q3: Cross-Layer Coherence and Cross-Layer Gradient lack sufficient theoretical and empirical justification. Are they heuristic signals, and do their limited ablation gains justify their computational cost?

A3: Cross-Layer Coherence and Cross-Layer Gradient are not arbitrary heuristics, but theory-motivated geometric statistics describing evidence-induced representation trajectories.

Let Δ^i(ℓ)=Δi(ℓ)/∥Δi(ℓ)∥2\hat{\Delta}_i^{(\ell)}=\Delta_i^{(\ell)}/\|\Delta_i^{(\ell)}\|_2. Cross-Layer Coherence can be written as

gi3=1−14(∣L∣−1)∑ℓ∈L−∥Δ^i(ℓ+1)−Δ^i(ℓ)∥22.g_{i3}=1-\frac{1}{4(|\mathcal L|-1)}\sum_{\ell\in\mathcal L^-}\left\|\hat{\Delta}_i^{(\ell+1)}-\hat{\Delta}_i^{(\ell)}\right\|_2^2.

It is the complement of the discrete directional variation across layers: isolated or oscillatory perturbations obtain low coherence, whereas persistent updates obtain high coherence. Cross-Layer Gradient is the positive ordinary-least-squares trend gi4=[Cov⁡(zℓ,aℓ(ci))Var⁡(zℓ)]+,g_{i4}=\left[\frac{\operatorname{Cov}(z_\ell,a_\ell(c_i))}{\operatorname{Var}(z_\ell)}\right]_+, which measures whether the evidence effect strengthens toward deeper semantic layers rather than appearing as a shallow spike. These designs are motivated by prior findings [1] [2] [3] that intermediate hidden states encode knowledge-boundary and factuality information, and that cross-layer cosine trajectories reveal feature persistence and representation development.

Empirical contribution. In Figure 3, Coherence and Gradient individually achieve key-point AUROC of 0.74/0.76 and Spearman ρ\rho of 0.58/0.60, exceeding the reranker’s 0.60 AUROC and 0.42 ρ\rho. Their smaller drop-one ablation gaps are expected because the four dimensions are correlated. Removal measures unique conditional contribution, whereas Figure 3 measures standalone informativeness.

Computational overhead. Neither signal requires additional LLM forward passes. After hidden-state extraction, Coherence costs O(∣L∣d)O(|\mathcal L|d) adjacent-vector operations and Gradient costs O(∣L∣)O(|\mathcal L|) scalar regression, negligible relative to the 12.4s frozen-model forward stage. We will add this geometric interpretation and computational analysis.

[1] Ni et al., Towards Fully Exploiting LLM Internal States to Enhance Knowledge Boundary Perception, ACL 2025.
[2] Laptev et al., Analyze Feature Flow to Enhance Interpretation and Steering in Language Models, ICML 2025.
[3] Jiang et al., Tracing Representation Progression: Analyzing and Enhancing Layer-Wise Similarity, ICLR 2025.


Q4: Furthermore, the robustness of these signals remains unproven in architectures beyond Qwen.

A4: We evaluate frozen scorers from Qwen, Llama, and Mistral, spanning 4B–32B parameters, using the Appendix E.3.1 setting: 100 CRC-EvidenceQA and 200 Med-EvidenceQA examples, with GPT-5.1 as judge.

Table 2. Robustness to the frozen scorer model.

Frozen scorer Params AUROC Spearman Ans. Quality Evi. F1
Qwen3-8B 8B 0.77 0.66 8.74 84.6
Qwen3-4B 4B 0.57 0.54 6.38 66.4
Qwen3-32B 32B 0.79 0.68 8.80 85.1
Llama-3.1-8B-Instruct 8B 0.75 0.66 8.69 83.9
Mistral-7B-v0.1 7B 0.74 0.63 8.52 83.2

The tested 7B–8B families achieve similar results. Replacing Qwen3-8B with Llama-3.1-8B changes answer quality by only 0.05 and Evidence F1 by 0.7. Scaling to Qwen3-32B improves answer quality by only 0.06 and Evidence F1 by 0.5 while substantially increasing runtime. Qwen3-4B degrades markedly, suggesting insufficient capacity for reliable utility estimation. Thus, IGS generalizes across the different LLM architectures.


Q5: Equation (1) uses both soft length penalties and a manually tuned hard budget BB. Are these constraints redundant, and which one primarily controls evidence compactness?

A5: The two constraints serve different roles. The hard budget

∑ci∈Sti≤B\sum_{c_i\in S}t_i\leq B

defines the feasible context window and guarantees that evidence never exceeds a deployment-specified limit. In contrast, penalty term −γ−μti-\gamma-\mu t_i controls preferences among feasible subsets: γ\gamma discourages unnecessary evidence units, while μ\mu penalizes long snippets. Thus, BB controls worst-case length, whereas the penalties encourage compactness even when the budget is not saturated.

We conduct a controlled ablation on the same 300 examples, fixing the candidate pools, Qwen3-8B scorer, GPT-4.1 backbone, and ϵ=0.1\epsilon=0.1. For Hard BB only, we set γ=μ=0\gamma=\mu=0; for Penalties only, we retain γ\gamma and μ\mu but set B=∑itiB=\sum_i t_i, making the hard constraint inactive.

Table 3. Distinct roles of BB and the soft penalties.

Setting Avg. tokens ↓\downarrow Queries exceeding 1,043 tokens ↓\downarrow Evi. F1 ↑\uparrow Ans. Quality ↑\uparrow
Hard BB only 1,016 0% 81.9 8.57
Penalties only 635 11.3% 79.5 8.28
Hard BB + penalties 612 0% 84.6 8.74

The hard constraint alone admits more weakly useful evidence, whereas penalties alone cannot guarantee the context limit. Their combination is therefore complementary, not redundant. We will also clarify that BB is selected once on development data and fixed during testing.


Q6: The Evidence F1 calculation and comparison are insufficiently explained, especially for Context+LLM, and important evaluation details are mostly left to the appendix.

A6: We apologize for the ambiguity. Evidence F1 is defined in Line 265 and computed identically for all methods by comparing selected evidence SS with the gold set GG:

P=∣S∩G∣∣S∣,R=∣S∩G∣∣G∣,F1=2PRP+R.P=\frac{|S\cap G|}{|S|},\quad R=\frac{|S\cap G|}{|G|},\quad F_1=\frac{2PR}{P+R}.

For Context+LLM, although the full context is provided as input, SS contains only evidence cited in the final answer; the entire input context is not treated as selected evidence. Thus, all methods use the same criterion. We will move this definition and other critical evaluation details into the main experimental setup.


Q7: Improve readability for Fig. 3 and Fig. 4.

A7: We agree. For Figure 3, we will increase spacing and remove overlapping numerical labels. For Figure 4, we will separate the datasets into individual panels, adjust marker placement, and label only Pareto-optimal points. These revisions improve readability without changing the results.


Thank you again for your careful review and constructive suggestions, which helped us improve both the analysis and presentation of the paper.

Authors · CommentOpenReview ↗

Kind Reminder of the Discussion Period Ending Soon

Dear Reviewer,

I hope this message finds you well. As the discussion period is nearing its end with less than two days remaining, I wanted to ensure we have addressed all your concerns satisfactorily. If there are any additional points or feedback you'd like us to consider, please let us know. Your insights are invaluable to us, and we're eager to address any remaining issues to improve our work.

Thank you for your time and effort in reviewing our paper.

Authors · CommentOpenReview ↗

Dear Reviewer q6S3,

Thank you very much for your thoughtful feedback and for taking the time to carefully consider our rebuttal. We truly appreciate your recognition of our responses and the opportunity to clarify our work. Your valuable comments have helped us further improve the paper.

Once again, thank you for your encouragement.

Sincerely,

Reviewer 1JmMOpenReview ↗
Rating
3/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only, CLEAR MAJOR CONCERN: Check this box if there is a clear, major concern for which you do not need further clarifications. Detail the concern in the Strengths and Weaknesses section. Use another option below if you would benefit from a consultation with an expert.
Read review
Summary

This manuscript proposes a medical evidence-grounded question-answering method that chooses a small subset of evidence, called MEGA. Main contributions are: 1) It constructs a recall-oriented candidate evidence pool; 2) It uses a frozen LLM to evaluate the information gain; 3) It formulates the evidence selection task as a budgeted utility maximization problem and proposes an FPTAS selector to determine the compact evidence subset. Besides, to evaluate the answer quality and evidence grounding, the manuscript also proposes two QA benchmarks (CRC-EvidenceQA and Med-EvidenceQA).

Strengths and weaknesses

For Quality, this manuscript is complete and well-structured, including a detailed description of the method and ablation studies as well as human studies. But the proposed framework heavily relies on LLMs at multiple stages (e.g., in retrieval, scoring, and LLM-as-a-judge evaluation), which may cause model-dependent bias, and the computational latency is non-negligible (32s per query for Qwen3-8B and 118.4s per query for Qwen3-32B).

For Clarity, this manuscript is generally clear. The four-stage pipeline is well described, and the appendix is detailed. However, it lacks some qualitative results to show when the method outperforms others and when it fails.

For Significance, this manuscript studies an important question in question-answering in high-stakes situations such as the medical domain. But considering it costs nontrivial computational resources (4xA100 GPUs, and slow inference time), how to combine it with a real clinical workflow remains less discussed. Moreover, the bias caused by LLMs is also not well addressed, which means the performance may be dependent on the selection of LLMs.

For Originality, the formulation of the problem is novel and interesting, and constructing a small but compact, sufficient subset as evidence is intuitive. However, there are also other works studying using a small and informative subset to make a prediction, such as Information Bottleneck [1] and Information Pursuit [2]. The discussion and comparison with existing information gain-based methods are expected.

[1] Tishby N, Pereira F C, Bialek W. The information bottleneck method[J]. arXiv preprint physics/0004057, 2000.

[2] Chattopadhyay, et al. Interpretable by design: Learning predictors by composing interpretable queries[J]. IEEE Transactions on Pattern Analysis and Machine Intelligence, 2022, 45(6): 7430-7443.

Questions

My main questions are as follows:

  1. Can the authors provide qualitative success and failure cases for the proposed method MEGA? And discussions about why? And also the influence of each component?
  2. Can the authors show how robust the information gain score is to the choice of the frozen LLM and judge model?
  3. How can MEGA be integrated into practical scenarios, given the high latency?
  4. Can the authors discuss and compare with existing information-gain-based methods [1,2]?

[1] Tishby N, Pereira F C, Bialek W. The information bottleneck method[J]. arXiv preprint physics/0004057, 2000.

[2] Chattopadhyay, et al. Interpretable by design: Learning predictors by composing interpretable queries[J]. IEEE Transactions on Pattern Analysis and Machine Intelligence, 2022, 45(6): 7430-7443.

Limitations

No. The author acknowledged several limitations, such as limited domain coverage, bilingual but not fully multilingual, text-only setting, and the LLM-as-a-judge bias. However, several important limitations are still insufficiently addressed, for example:

  1. The manuscript should provide more explicit discussion of failure modes, especially including qualitative results. In a high-stakes medical QA system, it's important to understand when the MEGA selects insufficient, redundant, or misleading evidence.

  2. The manuscript should discuss the heavy dependence on LLMs throughout the pipeline, such as for query decomposition, hidden-state scoring, answer generation, and evaluation. Although the manuscript provides sensitivity analysis for the frozen scorer, the robustness of the score to different LLM families and different judge models remains underexplored.

  3. The nontrivial computational cost and latency also need discussion as a practical limitation.

  4. The manuscript should also discuss its relationship to other information-gain-based methods, such as Information Bottleneck and Information Pursuit. This will help clarify the novelty of the proposed method.

Formatting concerns

I didn't notice major issues with paper formatting.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely thank Reviewer 1JmM for the constructive feedback and recognition of the paper’s clarity, significance, and novel formulation. We address all concerns below.


Q1 & L1 : Can the authors provide qualitative success and failure cases for the proposed method MEGA? And discussions about why? And also the influence of each component?

A1: Thanks for your valuable suggestions. We inspected the experimental logs and categorized cases by their originating stage. We will add representative success/failure cases and component-wise analysis to Appendix E.4.

Our failure analysis identifies two modes:

Failure mode Stage Description Percentage
Candidate recall failure Hybrid Retrieval Decision-critical gold evidence is absent from the candidate pool and cannot be recovered downstream. 76%
IGS scoring failure Information Gain Scoring A near-miss candidate with similar terms receives an overly high score, while a decision-critical snippet is underestimated. 24%

Among inspected failures, 76% involve candidate recall and 24% IGS misranking; categories may overlap.

Qualitative failure case 1: Missing evidence in the candidate pool CC

For QID 13 in CRC-EvidenceQA ("What toxicity of oxaliplatin requires the closest clinical monitoring?"), a supported answer requires two complementary pieces of evidence: E1: oxaliplatin is associated with acute and delayed peripheral sensory neuropathy...; and E2: persistent or cumulative neuropathy may impair daily functioning.... However, the retriever includes only E1 in CC, so neither IGS nor FPTAS can recover E2. MEGA selects E1, but the subset remains insufficient.

Qualitative failure case 2: Near-miss evidence receives a high IGS score

For QID covid_qa_50 in Med-EvidenceQA, "How was cross-reaction detection determined?", the gold evidence states that detection was conducted by applying JEV, YF, and DV cultures. IGS instead favors the proper spotting concentration was determined by minimizing cross-reaction.... Although the snippets use similar terms, only the gold evidence directly answers the question; the second concerns a different experimental step. IGS overestimates the near-miss, so FPTAS retains it under the budget and the generated answer gives the wrong procedure.

Qualitative success case :

In one success case shown in Figure 1 (QID 28 in CRC-EvidenceQA), the query asks: "For MSI-H/dMMR metastatic CRC, what is the preferred first-line therapy?" The candidate pool contains directly relevant, partially relevant, and redundant evidence. IGS ranks the evidence matching all decision-critical conditions highest, while lowering partially relevant candidates. The FPTAS selector then removes redundant snippets that add little coverage but consume tokens. MEGA therefore retains a compact evidence subset sufficient to support the correct answer. This case shows that IGS filters partially applicable evidence, whereas FPTAS reduces redundancy under the token budget.


Q2 & L2: Can the authors show how robust the information gain score is to the choice of the frozen LLM and judge model?

A2: We conducted additional experiments to evaluate (1) IGS across frozen scorer families and scales and (2) robustness to the judge LLM. We use the Appendix E.3.1 setting: 100 CRC-EvidenceQA and 200 Med-EvidenceQA examples (100 PubMedQA and 100 COVID-QA), with GPT-5.1 as the default judge.

Robustness to the frozen scorer LLM.

We evaluate scorer LLMs from three model families: Qwen, Llama, and Mistral, and parameter scales ranging from 4B to 32B.

Table 1. Robustness to the choice of the frozen scorer model. kp is short for key-point coverage.

Frozen scorer Params kp-AUROC kp-Spearman Ans. Quality Evi. F1 Time
Qwen3-8B 8B 0.77 0.66 8.74 84.6 1.0 ×\times
Qwen3-4B 4B 0.57 0.54 6.38 66.4 0.7 ×\times
Qwen3-32B 32B 0.79 0.68 8.80 85.1 3.7 ×\times
Llama-3.1-8B-Instruct 8B 0.75 0.66 8.69 83.9 1.1 ×\times
Mistral-7B-v0.1 7B 0.74 0.63 8.52 83.2 0.9 ×\times

IGS generalizes consistently across the different LLM families, which obtain similar AUROC 0.74–0.770.74–0.77, Spearman 0.63–0.660.63–0.66, answer quality 8.52–8.748.52–8.74, and Evidence F1 83.2–84.683.2–84.6. In particular, replacing Qwen3-8B with Llama-3.1-8B changes answer quality by only 0.05 and Evidence F1 by 0.7 points. The tested 4B scorer degrades substantially, suggesting insufficient capacity for reliable utility estimation. In contrast, scaling from 8B to 32B improves answer quality by only 0.06 and Evidence F1 by 0.5 points, while increasing runtime to 3.7×3.7\times. Therefore, we use an 8B scorer for the best reliability–cost balance.

Robustness to the judge LLM.

We test whether Figure 3 depends on the relevance judge LLM by fixing the candidate pools and all IGS/reranker scores, re-annotating relevance with three LLMs under the same prompt, and recomputing per-question AUROC and Spearman correlation.

Table 2. Robustness across relevance judges.

Relevance Judge Rel. Rate % Reranker AUROC IGS AUROC Δ\Delta AUROC Reranker ρ\rho IGS ρ\rho Δρ\Delta\rho
GPT-5.1 OriginalOriginal 44.8 0.65 0.63 −0.02 0.55 0.58 +0.03
DeepSeek-V4-Flash 46.2 0.64 0.63 −0.01 0.54 0.57 +0.03
Gemini-3.6-Flash 43.9 0.66 0.64 −0.02 0.56 0.60 +0.04
Average 45.0 0.65 0.63 −0.02 0.55 0.58 +0.03

Results are stable across different judge LLMs. The relevance rate ranges from 43.9% to 46.2%, and all metrics vary by at most 0.03. The reranker retains a small advantage in relevance AUROC, while IGS consistently achieves higher rank correlation. Together with its larger gains on key-point coverage in Figure 3, this shows that IGS captures both topical relevance and decision-critical evidence utility. We will add these results to Appendix E.3.


Q3 & L3: Can MEGA be integrated into practical scenarios, given the high latency?

A3: Although MEGA requires approximately 32.0 s to complete the full response, its average time to first token (TTFT) is approximately 17.3 s, comparable to the 14.15 ± 2.91 s response-initiation time reported for OpenEvidence. Thus, with streaming generation, MEGA provides comparable user-perceived responsiveness.

As reported in Appendix D.2, our original latency measures the complete pipeline, from receiving the query until all answer tokens have been generated. Thus, the 32.0 s includes both evidence processing and full-answer generation. In practical deployment, streaming allows users to begin reading after approximately 17.3 s, without waiting for the full response.

Table 3. Stage-wise latency of MEGA.

Stage Average latency
Hybrid retrieval 2.9 s
IGS computation 14.4 s
FPTAS selection 0.008 s
Answer generation 14.7 s
Time to first token 17.3 s
Full-response latency 32.0 s

Most latency comes from IGS and answer generation. The latter takes 14.7 s because MEGA generates detailed, evidence-grounded responses averaging approximately 1,300 tokens, corresponding to an effective GPT-4.1 output rate of about 88 tokens/s.

Hardware requirements. The 4-A800 node used in our experiments is not a deployment requirement. We used four A800 80GB GPUs for experimental convenience and throughput because the evaluation repeatedly loaded multiple embedding models, rerankers, scorer LLMs, answer-generation backbones, and baseline systems. For single-query inference, the complete Qwen3-8B-based IGS module runs on one A800 80GB GPU, while FPTAS adds negligible memory and computation.

Overall, MEGA introduces 14.4 s of evidence-scoring overhead in exchange for more accurate and better-grounded evidence selection, while maintaining an initial response time comparable to OpenEvidence. We consider it practical for non-emergency clinical consultation and evidence review. We will add this analysis to the Limitations and Discussion section.


Q4: Can the authors discuss and compare with existing information-gain-based methods [1,2]?

A4: Thank you for pointing out these important connections. We agree that MEGA shares with Information Bottleneck IBIB and Information Pursuit IPIP the general principle of retaining compact yet prediction-sufficient information.

However, their formulations differ substantially. IB learns a compressed latent representation by balancing I(X;X~)I(X;\tilde{X}) and I(X~;Y)I(\tilde{X};Y). IP sequentially selects user-defined binary queries according to their conditional mutual information with the prediction target. In contrast, MEGA performs inference-time selection over retrieved textual evidence. It uses frozen-LLM hidden-state changes as an operational utility proxy and jointly selects verifiable evidence sentences under a token budget using FPTAS.

Thus, MEGA’s contribution is its operationalization for evidence-grounded medical QA through model-conditioned evidence scoring, explicit token-cost modeling, and globally optimized selection of a directly citable evidence subset. We will clarify these connections and distinctions in the related work section.

Authors · CommentOpenReview ↗

Kind Reminder of the Discussion Period Ending Soon

Dear Reviewer,

I hope this message finds you well. As the discussion period is nearing its end with less than two days remaining, I wanted to ensure we have addressed all your concerns satisfactorily. If there are any additional points or feedback you'd like us to consider, please let us know. Your insights are invaluable to us, and we're eager to address any remaining issues to improve our work.

Thank you for your time and effort in reviewing our paper.

Authors · CommentOpenReview ↗

Kind Reminder of the Discussion Period Ending Soon

Dear Reviewer 1JmM,

I hope this message finds you well. As the discussion period is approaching its end with less than 10 hours remaining, we would like to kindly follow up and see whether our responses have addressed your main concerns.

We truly appreciate your detailed and constructive feedback, especially regarding the robustness of IGS, latency analysis, relationship to other information-gain-based methods, and qualitative results. We have provided additional experiments and clarifications to address these concerns, including evaluating the effectiveness of IGS across different LLM families, clarification about the difference from other information-gain-based methods and stage-wise latency analysis, and discussion of the detailed qualitative results for failure cases and success cases.

We would greatly appreciate any further feedback on whether these responses resolve your remaining questions or if there are any aspects that still require clarification. Your insights are very valuable to us, and we would be grateful for the opportunity to continue the discussion before it concludes.

Thank you again for your time and careful review.

Best regards,

Comments on the paper

1 comment
Authors · CommentOpenReview ↗

General Response

Dear Reviewers, AC and SAC,

We sincerely appreciate your time and effort in reviewing our paper. To facilitate the AC–Reviewer discussion, we summarize below the key consensus reached during the discussion phase and the corresponding improvements made to the paper.

For clarity and simplicity, we refer to Reviewers RrbL, q6S3, and 1JmM as R1, R2, and R3, respectively. We sincerely thank all reviewers and AC for their thoughtful and constructive feedback. We are encouraged by their recognition of the importance of evidence-grounded medical QA (R1-R3), the novelty of compact evidence subset selection (R1, R3), and the clarity of our technical framework (R1-R3).

We have carefully addressed the reviewers' comments and provided additional experiments, analyses, and clarifications to address their major concerns. Below, we summarize the core contributions of our study and the major updates during rebuttal.


Core Contributions of Our Work

  1. Problem Formulation and Theoretical Foundation.
    We reformulate medical evidence-grounded QA from independently ranking and retaining top-kk passages into a gain-aware compact evidence subset selection problem under an explicit token budget.

  2. Novel Framework.
    We propose MEGA, which combines recall-oriented subquery-based hybrid retrieval, hidden-state Information Gain Scoring (IGS), and an FPTAS evidence selector. IGS estimates answer-relevant information gain beyond pairwise relevance, while FPTAS optimizes evidence utility under a token budget with a (1−ϵ)(1-\epsilon)-approximation guarantee for the stated selection objective.

  3. Comprehensive Empirical and Clinical Validation.
    We construct CRC-EvidenceQA and Med-EvidenceQA. Across three LLM backbones and five medical RAG baselines, MEGA improves over the second-best baseline by 8.8% on average in answer quality and 38.8% in Evidence F1, while using 35.6% fewer evidence tokens. Component ablations and blinded clinician evaluation further support the sufficiency and minimality of the selected evidence.


Updates of Experimental Results during Rebuttal

  • Robustness of IGS:
    In Appendix E.3, we evaluate frozen scorers across different LLM families and scales (Qwen, Llama, and Mistral, 4B–32B), different middle-layer choices, and multiple judge models (GPT-5.1, DeepSeek-V4-Flash, and Gemini-3.6-Flash). Results remain stable across settings: the default middle-half layer selection achieves the best performance, and judge-model changes affect AUROC and rank correlation by at most 0.03 (R1–R3).

  • Validation of the selection mechanism:
    In Appendix E.4, we clarify the complementary roles of hard token budgets and soft penalties and show that MEGA maintains the strongest quality–budget trade-off under different budget constraints. With identical IGS utilities, FPTAS outperforms Greedy-Density while adding only approximately 1 ms solver time (R2–R3).

  • Qualitative and failure analysis:
    In Appendix E.5, we analyze representative success and failure cases. The analysis shows that FPTAS effectively removes redundant evidence, while failures mainly originate from missing decision-critical evidence during retrieval or IGS misranking semantically similar but insufficient snippets (R3).


Updates of In-depth Discussions during Rebuttal

  • Latency and deployment analysis:
    In Appendix E.3 and Limitations, we clarify that the previously reported 32.0 s is end-to-end response latency rather than IGS-only latency. Stage-wise profiling shows 14.4 s for IGS computation, 14.7 s for answer generation, and 17.3 s time-to-first-token, comparable to the reported response-initiation time of OpenEvidence under streaming. We clarify that MEGA targets evidence-token efficiency rather than latency efficiency and is intended for non-emergency evidence review scenarios. The 4×A800 setup was used for experimental throughput, while single-query IGS inference can run on one A800 GPU (R2–R3).

  • IGS components:
    In the Main Text, we provide additional geometric interpretations of Cross-Layer Coherence and Cross-Layer Gradient, clarifying that they are theory-motivated representation-trajectory statistics rather than arbitrary heuristics. These signals require no additional LLM forward passes (R2).

  • Clarifications on evaluation and related work:
    In the Main Text, we further clarify the Evi. F1, the distinct roles of hard budgets and soft penalties, and the difference from MEGA and information-based methods such as Information Bottleneck and Information Pursuit (R1–R2). Moreover, we improved the readability of Figure 3 and Figure 4.(R2).


We believe these additional analyses and clarifications address the major concerns raised during the discussion and further strengthen the overall quality of our work.

We remain grateful for the reviewers' valuable feedback and appreciate the opportunity to improve our submission.