Fast Accurate Quantum Monte Carlo without Metropolis Adjustment
Reuben Cohn-Gordon, Gabriel Pescia, Sumner N. Hearth, Jakob Robnik, Uros Seljak, Peter Lunts
NeurIPS 2026
TL;DR. We use a sampler without MH to achieve large speedups without loss of accuracy on the spin-fermion model of a 2D quantum electronic structure.
Abstract. In quantum systems, physical quantities of interest can be expressed as expectation values of a probability distribution, which allows their estimation by Markov Chain Monte Carlo (MCMC) methods. This approach, an instance of Quantum Monte Carlo (QMC), plays a central role in obtaining predictions of system properties relevant to condensed matter and high energy physics. The use of Hamiltonian dynamics to design a Markov kernel, known as Hybrid or Hamiltonian Monte Carlo (HMC), is widespread in quantum applications. In this context, it is standard to use an HMC kernel that is ``adjusted'' with the Metropolis-Hastings (MH) criterion, so that estimates of expectations converge to their true value in the limit of infinite sample size. However, recent work in computational statistics suggests that an \emph{unadjusted} HMC kernel can be significantly more efficient, while safely maintaining an asymptotic bias which is small relative to the error arising from the variance of the finite sample size. We adapt this approach to the QMC setting, focusing on a challenging and high-dimensional \emph{spin-fermion} model of a quantum phase transition. We find that unadjusted methods outperform adjusted HMC in terms of effective sample size per gradient call, while retaining accurate results.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 4 reviews · OpenReview
Updated 25 Nov 2026, 03:42 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper proposes the use of unadjusted gradient-based samplers for quantum Monte Carlo applications, discussing how to tune them such that the bias-variance is appropriately controlled.
This paper was originally borderline, with all reviewers falling in the borderline accept/reject recommendation. After the author response, all reviewers were in favor of accepting the paper.
Some concerns from reviewers that could improve the manuscript include:
- algorithmic novelty relative to prior work and how this could be improved in the paper
- tuning and bias diagnostic's positioning relative to prior work
- how to improve the general clarity for a NeurIPS audience and citations of related work
- more careful discussion of baselines and why they were included and why others were not (several reviewers commented on this)
- clarify runtime/compute budgets of the current experiments
The author response highlighted the novelty of studying unadjusted HMC for this application. I think the author response played a role in clarifying this paper's contributions, and I think it is appropriate as a "use inspired" paper.
Final justification
Overall, the author response helped to improve the reviewers' opinion of the paper, and several reviewers increased their scores.
The paper should be thoroughly revised to address the discussion with the reviewers, from emphasizing the novelty relative to prior work, related work and baselines discussions, and more clearly presenting runtime/compute budgets of the current experiments. Some remaining concerns that reviewers have mentioned include releasing the code and addressing Reviewer xHQA's remaining concern about the vs diagnostic.
Read meta-review
Meta-review
This paper proposes the use of unadjusted gradient-based samplers for quantum Monte Carlo applications, discussing how to tune them such that the bias-variance is appropriately controlled.
This paper was originally borderline, with all reviewers falling in the borderline accept/reject recommendation. After the author response, all reviewers were in favor of accepting the paper.
Some concerns from reviewers that could improve the manuscript include:
- algorithmic novelty relative to prior work and how this could be improved in the paper
- tuning and bias diagnostic's positioning relative to prior work
- how to improve the general clarity for a NeurIPS audience and citations of related work
- more careful discussion of baselines and why they were included and why others were not (several reviewers commented on this)
- clarify runtime/compute budgets of the current experiments
The author response highlighted the novelty of studying unadjusted HMC for this application. I think the author response played a role in clarifying this paper's contributions, and I think it is appropriate as a "use inspired" paper.
Final justification
Overall, the author response helped to improve the reviewers' opinion of the paper, and several reviewers increased their scores.
The paper should be thoroughly revised to address the discussion with the reviewers, from emphasizing the novelty relative to prior work, related work and baselines discussions, and more clearly presenting runtime/compute budgets of the current experiments. Some remaining concerns that reviewers have mentioned include releasing the code and addressing Reviewer xHQA's remaining concern about the vs diagnostic.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper applies unadjusted gradient-based MCMC methods, uLMC and uMCLMC, to a high-dimensional quantum Monte Carlo setting on the spin-fermion model of an antiferromagnetic quantum phase transition. This paper demonstrates that unadjusted samplers, combined with energy-error-based step-size tuning, can substantially outperform a tuned adjusted HMC baseline, on this QMC problem, while maintaining observable-level asymptotic bias that is small relative to finite-sample Monte Carlo error. This works contributions are primarily empirical and domain specific, rather than fundamental new algorithms / theory.
Strengths and weaknesses
Strengths
- The paper addresses an important computational bottleneck in QMC simulations: the cost of obtaining accurate expectation estimates in high-dimensional physical systems. The empirical results suggest that unadjusted samplers can provide significant efficiency improvements over adjusted HMC in this spin-fermion setting.
- The paper is also valuable in testing whether unadjusted methods remain reliable in the presence of pseudofermions and expensive CG-based gradient evaluations. This is a nontrivial and practically relevant regime for computational physics. The comparison between the true-bias proxy and the step-size diagnostic is useful, and the results suggest that may be a practical way to detect excessive asymptotic bias without ground-truth samples.
Weaknesses
- Limited algorithmic novelty relative to prior unadjusted HMC/LMC work.
The transition kernels used in the paper appear to closely follow existing underdamped Langevin and microcanonical Langevin constructions. In particular, the Langevin half-step / Hamiltonian integrator / Langevin half-step structure is standard, and closely related black-box unadjusted HMC methods have already been proposed in recent work such as arXiv:2412.08876. The main novelty therefore seems to be the adaptation and empirical validation in a QMC spin-fermion setting, rather than a new general-purpose MCMC algorithm. This distinction should be made clearer. - The tuning procedure and bias diagnostic need clearer positioning relative to prior work.
The energy-error-based step-size tuning appears to be a direct application of prior work on unadjusted HMC/LMC. The vs. bias diagnostic may be a useful practical contribution in this setting, but the paper states that it follows computational chemistry practice without giving a citation or explaining precisely what is new here. It would help if the authors clearly separated:- what is directly inherited from prior unadjusted-sampler work,
- what is adapted to the pseudofermion/QMC setting, and
- what, if anything, is novel in the bias diagnostic.
- The tuning procedure is underspecified.
Section 3.3 describes the tuning process mostly in prose. The exact update rules for , the mass matrix, and the momentum decoherence time are not presented as a precise algorithm. This makes it difficult to reproduce the method or understand how sensitive the results are to tuning choices. A pseudocode block would substantially improve clarity. This is especially important because the paper’s main empirical claims depend on the claim that the tuning procedure reliably controls asymptotic bias. - Some mathematical definitions are too terse for an ML audience.
Several objects are introduced briefly or deferred to the appendix. Examples include the generic observable in Eq. 1, the Dirac-delta transition kernel notation , the action terms and , and the matrices and . These may be standard to specialists, but for a NeurIPS audience the paper would benefit from more self-contained definitions and a clearer presentation of the base HMC/uLMC/uMCLMC algorithms before describing modifications. - Missing or incomplete citations.
Some claims seem to rely on prior work but are not cited. For example, the statement that the constant keeps for Gaussians and is “known to be optimal” needs a citation or derivation. Similarly, the vs. diagnostic is attributed to computational chemistry practice but no reference is provided. - The physics/QMC motivation could be clearer for a machine-learning audience.
Section 4 introduces the spin-fermion model, but the paper could more explicitly state what quantities are being estimated, why those observables matter physically, and why this problem is a useful benchmark for MCMC methodology. This context may be obvious to computational physicists but is not fully spelled out for a broader ML audience. Because this work is primarily about an application in QMC, this would be very helpful framing. - Baseline discussion could be strengthened.
The adjusted HMC baseline is likely the most relevant baseline for this QMC application, and the grid-search comparison in the appendix is useful. However, given the close relationship to recent black-box unadjusted HMC work and other HMC-efficiency methods, the paper should better justify why the chosen baselines are sufficient. It would also help to clarify whether the gains come mainly from removing the MH step, from the specific uMCLMC dynamics, from the mass-matrix adaptation, or from QMC-specific implementation choices.
Questions
- Which components are claimed as novel relative to recent work on black box unadjusted MCMC (e.g. arXiv:2412.08876): , Fourier mass matrix, pseudo-rejection, or only the QMC validation?
- Since unadjusted samplers introduce finite-step-size asymptotic bias in addition to Monte Carlo variance, how should uncertainty intervals for estimated observables be constructed? Do the reported error bars account only for chain-to-chain variability / finite-sample variance, or also for estimated asymptotic bias via ?
- The results in Section 5.1 are only run under a single setting (N_\tau = 40). How does this method scale with increasing N_\tau? Would this cause a efficiency decease as with increasing L?
- What is the theoretical relationship between the two chain bias quantity and the bias relative to the adjusted sampler ? Is a lower bound / mathematically related to ? If so, can we use to partially debias the estimator?
- Appendix D states that a single chain takes hours on a single GPU, and that 32 H100 GPUs with 80GB of memory each were used. This should be included in the main body since this is a nontrivial amount of required compute.
Limitations
yes
Final justification
I would like to thank the authors for their detailed rebuttal. They have addressed most of my concerns by clarifying the scope and novelty of their contribution, explaining the comparison with adjusted HMC and the source of the observed efficiency gains, providing the missing citations and methodological clarification, improving the motivation for a machine-learning audience, and providing additional results at .
However, one issue is still only partially resolved. The versus diagnostic compares the expectations produced by two discretized samplers, but it does not directly control either sampler’s bias relative to the true target. Two discretizations could agree closely while sharing a similar non-negligible bias. So this diagnostic alone does not fully justify treating discretization bias as negligible, or omitting it from the reported uncertainty intervals, across the considered settings.
Still, the authors have satisfactorily addressed the rest of my concerns so I have therefore raised my score.
Formatting concerns
N/A
3 comments
I would like to thank the authors for their detailed rebuttal. They have addressed most of my concerns by clarifying the scope and novelty of their contribution, explaining the comparison with adjusted HMC and the source of the observed efficiency gains, providing the missing citations and methodological clarification, improving the motivation for a machine-learning audience, and providing additional results at .
However, one issue is still only partially resolved. The versus diagnostic compares the expectations produced by two discretized samplers, but it does not directly control either sampler’s bias relative to the true target. Two discretizations could agree closely while sharing a similar non-negligible bias. So this diagnostic alone does not fully justify treating discretization bias as negligible, or omitting it from the reported uncertainty intervals, across the considered settings.
Still, the authors have satisfactorily addressed the rest of my concerns so I have therefore raised my score.
Thanks for your response.
We agree that the vs diagnostic () is not guaranteed to control the bias. Our claim, which we will clarify in the paper, is empirical: across , the true bias is no more than twice (we will add a scatter plot showing this). This is in keeping with our finding that the bias with , which we will also include. Re the uncertainty intervals, the point is well taken and we will amend the paper accordingly - however we do note that initialization bias (present also in adjusted HMC) is not typically accounted for in error bars in the literature.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This work addresses the central challenge of low efficiency of Metropolis-adjusted HMC in high-dimensional quantum spin-fermion simulations. It develops three unadjusted MCMC samplers with auto-tuning and pseudofermion techniques to control systematic bias. Experimental results indicate that unadjusted samplers far outperform standard aHMC in sampling efficiency. A ground-truth-free bias metric is adopted to assess error without reference benchmark data. Overall, the authors in this paper propose a practical speed-up solution for difficult quantum Monte Carlo computations.
Strengths and weaknesses
Strengths: (1)This paper proves an important conclusion: unadjusted samplers can significantly improve sampling efficiency for high-dimensional quantum models. (2)The authors propose a ground-truth-free metric that reliably detects small asymptotic bias. (3)Comprehensive experimental results are demonstrated.
Weaknesses: (1)The method relies on manually set hyperparameters and shows bias spikes at the quantum critical point without clear theoretical explanation. (2)Its effectiveness on larger temporal lattices and other lattice gauge theories remains unproven.
Questions
(1)Why does the asymptotic bias of unadjusted samplers peak exactly at the quantum critical point λ=2.65, and can the authors provide a theoretical derivation for this trend?Add theoretical analysis to explain bias surge at the quantum critical point. (2)How does the pseudorejection rule during tuning alter the stationary distribution of unadjusted samplers, and does it introduce extra persistent bias in final production sampling? (3)Test the sampler on larger lattices and other quantum models. (4)Develop fully automatic tuning without manual hyperparameter selection. (5)Compared to other unadjusted sampling literature, what unique modifications make uMCLMC better suited for fermion lattice problems than vanilla uLMC or uHMC?
Limitations
Yes
Formatting concerns
None.
1 comment
Rebuttal
We thank the reviewer for their insightful review. Our understanding is that the central reservations of the reviewer leading to the borderline score were:
- Manually set hyperparameters
- Effectiveness on higher Nt or different systems unproven
Re (1), we are not sure what the reviewer is referring to, since our tuning scheme is fully automated. That is, the step-size, mass matrix and decoherence time L are all set automatically by the tuning. If the reviewer is referring to the target energy error variance per dimension (EEVPD), then we note that this is not a hyperparameter that typically requires manual tuning. Instead, a value of 5e-8 is shown to work across all system sizes and values of lambda considered in the paper. It is indeed possible that a very different system would require a change to this value, but the procedure to diagnose this is quite straightforward: the user examines the estimate of bias from and adjusts the target EEVPD accordingly. We're happy to discuss this point further, but to summarize, we think that the statement “the system relies on manually set hyperparameters” is not a fair assessment of the method.
Re (2), we think this is a fair point, and respond with two further simulations. First, we consider the system described in https://arxiv.org/pdf/2410.05365, which is a spin-fermion system with random spatial disorder. In this case, results must be computed for a fixed choice of spatial disorder, and run multiple times. The physics of this system is substantially different to the clean spin-fermion system, but the unadjusted sampler continues to outperform HMC:
\begin{table}[t]
\centering
\begin{tabular}{cccccc}
\toprule
$L$ & $\lambda$ & uMCLMC & uLMC & aHMC \\
\midrule
64 & 8.00 & $\mathbf{0.0125 \pm 0.001}$ & $0.0103 \pm 0.001$ & $0.00372 \pm 0.0005$ \\
64 & 9.00 & $0.0127 \pm 0.001$ & $\mathbf{0.0133 \pm 0.0008}$ & $0.00618 \pm 0.0006$ \\
64 & 10.00 & $0.0155 \pm 0.001$ & $\mathbf{0.016 \pm 0.0008}$ & $0.00599 \pm 0.0005$ \\
64 & 11.00 & $0.0173 \pm 0.001$ & $\mathbf{0.0175 \pm 0.001}$ & $0.00785 \pm 0.0007$ \\
64 & 12.00 & $\mathbf{0.0184 \pm 0.002}$ & $0.018 \pm 0.001$ & $0.0076 \pm 0.0009$ \\
\bottomrule
\end{tabular}
\caption{ESS per gradient for $\chi_0$, each averaged over $10$ chains at $N_\tau=40$, $L=64$. $b_a$ is below 1.0 throughout.}
\end{table}
Second, we examine the “clean” system at N_tau = 80 (which equates to a lower temperature). Results are as follows ( result for MCLMC still underway):
\begin{table}[t]
\centering
\begin{tabular}{cccccc}
\toprule
$L$ & $\lambda$ & uMCLMC & uLMC & aHMC \\
\midrule
64 & 2.50 & $0.0427 \pm 0.002$ & $\mathbf{0.0512 \pm 0.003}$ & $0.014 \pm 0.001$ \\
64 & 2.65 & 0.05 \pm 0.002 & $\mathbf{0.0508 \pm 0.002}$ & $0.0131 \pm 0.0009$ \\
64 & 3.00 & --- & $\mathbf{0.0581 \pm 0.003}$ & $0.0134 \pm 0.001$ \\
\bottomrule
\end{tabular}
\caption{ESS per gradient for $\chi_0$ at $L=64$, $N_\tau=80$. $b_a$ is below $1.0$ throughout.}
\end{table}
Other questions
How does the pseudorejection rule during tuning alter the stationary distribution of unadjusted samplers, and does it introduce extra persistent bias in final production sampling?
This is a good question - it could introduce bias in theory, but in practice, since we reject only energy changes 1000 times larger than the energy change variance, it really only serves to handle numerical instability.
Compared to other unadjusted sampling literature, what unique modifications make uMCLMC better suited for fermion lattice problems than vanilla uLMC or uHMC?
We should be clear that uMCLMC doesn't obviously perform better than other unadjusted methods. In fact, figure 2 shows that performance is pretty comparable between the unadjusted samplers. However, we do suspect that it requires less burn-in, which we are looking into in future work.
Why does the asymptotic bias of unadjusted samplers peak exactly at the quantum critical point
What we believe is happening involves the shadow Hamiltonian, i.e. the Hamiltonian which yields the stationary distribution of the unadjusted sampler. The difference between the target and shadow Hamiltonians increases when the higher-order derivatives of the action at the sampled field configurations are large. Away from the critical point the field fluctuations are small and mostly described by the quadratic part of the action. Near the critical point the field fluctuations become large and therefore also probe the non-linear action component with larger higher-order derivatives of the action. We suspect this is the source of the bias at criticality.
If the reviewer is satisfied with our responses to their central concerns, we’d like to ask them to consider raising their score. In particular, we’d like to highlight the lack of manual tuning, and the new results for a system with disorder, and the performance at higher .
- Rating
- 5/6
- Confidence
- 2/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper takes a sampling idea now well-established in computational statistics and brings it into the Quantum Monte Carlo (QMC) setting. Unadjusted gradient-based MCMC (HMC/Langevin without the Metropolis-Hastings accept/reject step) can be much more efficient than its adjusted version, as long as the finite-step-size asymptotic bias stays small relative to the finite-sample variance.
The target is a high-dimensional spin-fermion (SF) model of an antiferromagnetic quantum phase transition in a 2D metal, where the sota is Metropolis-adjusted Hamiltonian Monte Carlo (aHMC). The authors apply two unadjusted samplers, unadjusted Langevin MC (uLMC) and Microcanonical Langevin MC (uMCLMC), both with an automated step-size rule that targets a fixed value of .
On the SF model , the unadjusted samplers get roughly an order-of-magnitude improvement in effective-sample-size-per-gradient over aHMC, and the advantage grows with system size. The asymptotic bias can be diagnosed without ground truth by comparing chains run at step sizes and . A practically important piece is making this work inside the pseudofermion (matrix-determinant) structure of fermionic QMC, where each gradient needs an expensive CG solve.
Strengths and weaknesses
The SF model is actively studied in condensed-matter physics and aHMC there is a bottleneck, so this is not a benchmark built to favor the method. The design fits the application. The authors respect the pseudofermion structure, use a CG solver, exploit translational invariance for a near-optimal block-diagonal mass matrix in Fourier space, and pick physically meaningful observables (static uniform spin susceptibility and fermionic occupancy ). Baselines are handled well. aHMC is auto-tuned and grid-searched over , and cross-checked against the published code. The bias analysis is the most careful part. They report bias relative to variance and a reference-free estimate, and use the empirical finding to argue it is safe in practice.
Comparing the three claims: (i) bias control is demonstrated in the regimes tested and is the best-supported; (ii) the speedup over aHMC is shown but regime-dependent and tied to the per-gradient accounting question; (iii) the reference-free measure is plausible and useful but the least rigorously established .
A ~10× reduction in gradient calls at fixed accuracy is directly useful for lattice QMC, since each call is an expensive CG solve. The dimension-scaling result is compelling.
Weaknesses:
-
The speed metric is "per gradient call," but as I understand it the proposed sampler does two gradient evaluations per step while the baseline does one. If "per step" and "per gradient" get mixed up in the plots, the headline speedup could be off by up to about 2x. Could the authors confirm that all the efficiency numbers count individual gradient evaluations the same way across samplers?
-
The headline is an experimental "X is ~10x faster than Y" result, but the code is not released. Given the large compute budget reported, independent reproduction is already hard, so releasing the code would help a lot.
-
No summary numbers. Everything is read off log-scale plots, with no table of the efficiency numbers and their uncertainties, so the main claim has to be eyeballed. A simple table across the samplers and settings, with seed error bars, would make it much easier to trust. I may be missing it, but I did not see one.
-
Generalization to other systems and to the larger applications mentioned is asserted but not shown, even minimally. It would also help to briefly justify why the chosen baseline is the right one to compare against, and whether other accelerated samplers are in or out of scope.
Questions
-
Please confirm that all ESSn/ESSa "per gradient" numbers count individual gradient evaluations, not integrator steps, across aHMC and uMCLMC.
-
Please release the sampler/compiler/tuning code (without the large datasets), or an anonymized snapshot during rebuttal.
-
Please add a table of ESSn and ESSa (with seed error bars) for aHMC/uLMC/uMCLMC at representative , and state the 5000-step tuning cost relative to the sampling budget (the ESS numbers are warm-start and omit tuning).
Limitations
There is an explicit Limitations paragraph (choice of , non-fully-automatic tuning, larger-ESS regimes) and an Open Questions paragraph (unexplained bias peak at ). What's missing is an acknowledgment of the reproducibility consequence of withholding code behind a purely empirical claim.
Final justification
Q1 is addressed. Confirming everything is counted in gradient evaluations rather than integrator steps was the main thing I needed. Q3 is mostly settled. Please include the table with the error bars and ESS_n as you offered, and state in the paper that the reported ESS is warm start and excludes tuning and burn-in, so it is not read as an end-to-end speedup.
The disordered system and N_tau=80 answer my fourth weakness, on generalization. One observation from those tables. The advantage over aHMC is about 2.2x to 4x on the disordered system and around 4x at N_tau=80, both at L=64, against about 6x for the clean system at the same L and 10x to 16x at L=128. So "around an order of magnitude" in the abstract is the best case rather than the typical one. Could you state the observed range and where the large factors come from instead of one headline number?
The baseline justification is fine, I do not have a better one in mind.
That leaves code. My question 2 asked for release of the sampler, compiler and tuning code without the large datasets, or an anonymized snapshot during the rebuttal. The response covers the first option and says release is not possible right now, but does not address the second. Is an anonymized snapshot available?
The authors have addressed most of my concerns. Raising from 4 to 5.
Formatting concerns
None
3 comments
Rebuttal
We thank the reviewer for their review, which engages closely with the paper. The reviewer’s borderline acceptance seems to hinge on the following reservations:
- Are we counting efficiency per gradient correctly?
- Lack of summary table.
- Generalization
- Baselines
Re (1): good question, but yes, we are careful to be consistent, in the sense of counting gradient evals, which are the proxy for computational cost, rather than integration steps. So for example, the default integrator for uMCLMC calculates the gradient twice per step, and this is accounted for when reporting efficiency.
Re (2), we provide our original summary table below. We removed this from the submission for space reasons, but are happy to re-include it, and to add error bars and ESS_n:
\begin{table}[t]
\centering
\begin{tabular}{cccccc}
\toprule
$L$ & $\lambda$ & uMCLMC & uLMC & aHMC \\
\midrule
16 & 2.65 & $0.0237$ & $\mathbf{0.0279}$ & $0.00849$ \\
16 & 3.00 & $\mathbf{0.0632}$ & $0.0452$ & $0.0152$ \\
64 & 2.65 & $0.0131$ & $\mathbf{0.0195}$ & $0.0032$ \\
64 & 3.00 & $\mathbf{0.0604}$ & $0.0428$ & $0.00947$ \\
128 & 2.65 & $0.0137$ & $\mathbf{0.0197}$ & $0.00121$ \\
128 & 3.00 & $\mathbf{0.0611}$ & $0.0453$ & $0.00612$ \\
\bottomrule
\end{tabular}
\caption{$ESS_a$ per gradient for $\chi_0$ shown for two unadjusted samplers and standard adjusted HMC, each averaged over $10$ chains, at $N_\tau=40$. The unadjusted samplers are comparable to each other, and considerably faster than adjusted HMC.}
\label{tab:r-sweep}
\end{table}
Re (3), we first note that the system we consider is really a family of systems, with varying L and . In particular, the system varies quite significantly with , and we also do show performance as a function of dimension (figure 5). However, in the interest of providing the reviewer with a physically different system, we have run a spatially disordered electron system, following https://arxiv.org/abs/2410.05365.
This system differs from the “clean” spin fermion system by having the interaction coefficient g be randomly chosen at each lattice site. We average across 10 disorder configurations in calculating the following table:
\begin{table}[t]
\centering
\begin{tabular}{cccccc}
\toprule
$L$ & $\lambda$ & uMCLMC & uLMC & aHMC \\
\midrule
64 & 8.00 & $\mathbf{0.0125 \pm 0.001}$ & $0.0103 \pm 0.001$ & $0.00372 \pm 0.0005$ \\
64 & 9.00 & $0.0127 \pm 0.001$ & $\mathbf{0.0133 \pm 0.0008}$ & $0.00618 \pm 0.0006$ \\
64 & 10.00 & $0.0155 \pm 0.001$ & $\mathbf{0.016 \pm 0.0008}$ & $0.00599 \pm 0.0005$ \\
64 & 11.00 & $0.0173 \pm 0.001$ & $\mathbf{0.0175 \pm 0.001}$ & $0.00785 \pm 0.0007$ \\
64 & 12.00 & $\mathbf{0.0184 \pm 0.002}$ & $0.018 \pm 0.001$ & $0.0076 \pm 0.0009$ \\
\bottomrule
\end{tabular}
\caption{ESS per gradient for $\chi_0$, each averaged over $10$ chains at $N_\tau=40$, $L=64$. $b_a$ is below 1.0 throughout.}
\end{table}
In addition, we have run the clean system at a higher N_tau (i.e. lower temperature), namely N_tau=80 ( result for MCLMC still underway):
\begin{table}[t]
\centering
\begin{tabular}{cccccc}
\toprule
$L$ & $\lambda$ & uMCLMC & uLMC & aHMC \\
\midrule
64 & 2.50 & $0.0427 \pm 0.002$ & $\mathbf{0.0512 \pm 0.003}$ & $0.014 \pm 0.001$ \\
64 & 2.65 & 0.05 \pm 0.002 & $\mathbf{0.0508 \pm 0.002}$ & $0.0131 \pm 0.0009$ \\
64 & 3.00 & --- & $\mathbf{0.0581 \pm 0.003}$ & $0.0134 \pm 0.001$ \\
\bottomrule
\end{tabular}
\caption{ESS per gradient for $\chi_0$ at $L=64$, $N_\tau=80$. $b_a$ is below $1.0$ throughout.}
\end{table}
Re point (4) (baselines), this is a reasonable question. The short answer is that HMC is the strongest baseline, and as such is the relevant comparison. For example, Metropolis Adjusted Langevin (MALA) is another gradient based method, but is known to have a statistical efficiency that decreases with a ⅓ power law with dimension (compared to ¼ for leapfrog HMC). To make sure that the tuning for HMC is optimal, we perform a grid search (see figure 6). Other gradient based methods exist, such as Riemannian HMC, but are not practical (no efficient integration scheme). If the reviewer has a baseline in mind that they feel would perform better than HMC, we are happy to discuss.
Other questions
state the 5000-step tuning cost relative to the sampling budget (the ESS numbers are warm-start and omit tuning).
Our approach to benchmarking in the paper is to tune as much as possible, in order to arrive at optimal hyperparameters and mass matrix. We use the same mass matrix tuning for both the unadjusted samplers and the baseline (for a fair comparison), and then measure from a warm start. As such, cost of tuning does not enter into our comparison between adjusted and unadjusted. However, our impression is that the reviewer is curious about which sampler is able to tune more efficiently. In terms of estimating the mass matrix, this amounts largely to the autocorrelation of the chain, so the warm-start efficiency reported in the paper gives a good indication. In terms of the step size adaptation, this is quite cheap, both for adjusted and unadjusted, since the acceptance rate or squared energy difference require few samples to estimate well, so doesn’t significantly impact the cost.
The remaining question is which sampler has the fastest burn-in or “equilibration” from a cold start. Measuring this is relatively understudied in applied statistics, and we feel that it is beyond the scope of the paper to create a framework for assessing burn-in speed fairly (it is subtle, since in practice it happens simultaneously with tuning). However, we note that asymptotic bias is of limited concern during tuning, so an unadjusted sampler can use a much larger step size than an adjusted one here.
What's missing is an acknowledgment of the reproducibility consequence of withholding code behind a purely empirical claim.
Duly noted, and we’ll add that accordingly. We note that the code will be open-sourced eventually, but that we are not able to release it immediately, for reasons beyond our control.
Summary
If the reviewer is satisfied with our responses, we would like to ask them to consider raising their score. Based on their summary of the paper, our impression is that they consider it to be impressive, high impact work, and assuming we have responded to their concerns, we feel that a stronger score is merited.
Thanks for the response and the extra runs.
Q1 is addressed. Confirming everything is counted in gradient evaluations rather than integrator steps was the main thing I needed. Q3 is mostly settled. Please include the table with the error bars and ESS_n as you offered, and state in the paper that the reported ESS is warm start and excludes tuning and burn-in, so it is not read as an end-to-end speedup.
The disordered system and N_tau=80 answer my fourth weakness, on generalization. One observation from those tables. The advantage over aHMC is about 2.2x to 4x on the disordered system and around 4x at N_tau=80, both at L=64, against about 6x for the clean system at the same L and 10x to 16x at L=128. So "around an order of magnitude" in the abstract is the best case rather than the typical one. Could you state the observed range and where the large factors come from instead of one headline number?
The baseline justification is fine, I do not have a better one in mind.
That leaves code. My question 2 asked for release of the sampler, compiler and tuning code without the large datasets, or an anonymized snapshot during the rebuttal. The response covers the first option and says release is not possible right now, but does not address the second. Is an anonymized snapshot available?
Thanks for your reply.
Re the "order of magnitude" claim, that's a fair point, we'll reformulate the claim in the paper. The point we'll emphasize in the paper is that the systems of physical relevance are the largest ones (largest and ), so the fact that the scaling of the efficiency of the unadjusted samplers with (and pending further analysis ) is favorable relative to HMC is really the important contribution of the method.
Regarding the disordered method, the interesting point is that the disorder introduces another source of variance, so relative to the total variance (from both disorder and the finite sample size), the bias is smaller. That is to say, we believe that the unadjusted sampler could be safely used with a larger step size for the disordered system, yielding more favourable results. We will analyze this case in detail if the paper is accepted.
Regarding the code, I think in theory we could provide an anonymized snapshot of at least a subset of the code, but -- at the risk of sounding evasive -- it would be tricky to reach an author consensus, prepare it, and make sure that it is satisfactorily anonymous before the end of the author-reviewer period (which I believe is in a few hours). Sorry, I realize this is frustrating.
- Rating
- 4/6
- Confidence
- 2/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper focuses on Hamiltonian Monte Carlo (HMC), an instance of Quantum Monte Carlo (QMC) for quantum many-body physics. In particular, this paper demonstrates that unadjusted HMC (uHMC) outperforms adjusted HMC (aHMC) in terms of effective sample size (ESS) per step while maintaining accurate results. To benchmark their results, the authors focus on the spin-fermion model near the critical point.
Strengths and weaknesses
As a non-expert, I appreciate the amount of technical detail provided by the authors, which helped me understand their method on a high level. However, I found it hard to see the bigger picture of the method. Would this method allow us to map out a phase diagram for the model studied here, or does it only improve sampling efficiency? In this context, χ0 is the only observable in the paper as far as I read. Fig 3 (left panel) plotting χ0 against lambda does not show a significant change near the critical point to signal a phase transition. It would be great if the authors could explain whether there are other (physical) observables that they can compute with their method to identify the critical point, or at least provide a pathway towards this goal.
The authors also don't seem to report runtimes/compute budget of their simulations. It would be a good idea to share these numbers to help with future comparisons.
Questions
- QMC is known for the Fermionic sign problem; Can you explain how your method can help circumvent the well-known sign problem?
- Which criterion do you rely on to determine the grid spacing size? Does it have to be uniform?
- Is there a chance you can circumvent the need for MCMC sampling by using a parametrized flow-based model?
- Is there a systematic way you can do finite-size scaling to get observable predictions in the thermodynamic limit?
- In general, is your approach applicable to discrete quantum systems? In particular, can you apply it directly to two-dimensional Fermi-Hubbard models?
- Do you always have the possibility to estimate bias in your calculation if you don't have a ground truth to compare against?
Limitations
yes
Formatting concerns
No major concerns; I would just recommend that the authors run the paper through a syntax check to correct some grammar errors I encountered.
1 comment
Rebuttal
We thank the reviewer for this review. Our sense is that the reviewer has three central reservations:
- What is the bigger picture here? What does this method gain us?
- Can other observables be computed?
- Do you always have the possibility to estimate bias in your calculation if you don't have a ground truth to compare against?
Re 1, we want to emphasize that our method is intended as a replacement to Hybrid Monte Carlo (HMC), so the short answer to what our method is for is: any task that was previously using HMC. In the context of physics, this is usually either lattice gauge theory or similar systems that appear in condensed matter (as in e.g. https://www.nature.com/articles/s41467-023-37686-4). HMC is used for mapping out the phase diagram (e.g. the superconducting temperature, in the spin-fermion system), for performing finite size scaling analysis, and extracting any other physics. MCMC runs are extremely expensive, and our contribution is to show that this cost can be very significantly reduced by our more efficient sampling method. This impacts any physical applications where gradient based MCMC is used.
Re 2, we emphasize that we can and do compute other observables, in particular the fermionic density (figure 1). As far as identifying the critical point, does display a kink at the critical point (easier to see without the log scale, and at larger L), and one can extract the critical point using standard methods (e.g. Binder cumulant).
Re 3, Yes. We can estimate bias without the ground truth. In particular, see our discussion of and the right panel of figure 3. This is absolutely key to the applicability of our method, because it means that the bias can be reliably estimated in practice, without reference to a separate ground truth.
The authors also don't seem to report runtimes/compute budget of their simulations. It would be a good idea to share these numbers to help with future comparisons.
We do report compute - see Appendix D. However, another reviewer also suggested this should be moved to the main text; we will do this.
QMC is known for the Fermionic sign problem; Can you explain how your method can help circumvent the well-known sign problem?
Our method does not circumvent the sign problem. It is applicable wherever Hamiltonian (Hybrid) Monte Carlo (HMC) is used in Lattice Gauge Theory or condensed matter physics, i.e. in problems which are free of the sign problem, such as the problem studied here.
Which criterion do you rely on to determine the grid spacing size? Does it have to be uniform?
The grid spacing of the spatial lattice needs to be uniform, and it is set to a = 1, i.e. all lengths scales are in units of a. The grid spacing in the imaginary time direction (with length of inverse temperature) is set to be dt=0.1. We choose this spacing to be as small as needed for the low energy features of the model to be independent of dt. From previous work we know that dt = 0.1 is good enough. We note that this is orthogonal to the use of the unadjusted sampler, however, which is the main focus of the paper.
Is there a systematic way you can do finite-size scaling to get observable predictions in the thermodynamic limit?
Yes. Here, the only thermodynamic quantities we would like to obtain precisely are universal features of the phase transition, like scaling exponents and the exact location of the critical point. These are expensive to obtain, and their precise values are not important for the present paper, since we are satisfied with only an approximate location of the critical point.
Is there a chance you can circumvent the need for MCMC sampling by using a parametrized flow-based model?
There has been some work on flow methods for lattice problems, but the short answer is that in large system sizes, it is both difficult to train a stable flow method, and computationally impractical. To our understanding, flow-based models are not currently a practical alternative to HMC for these applications, although we expect this may change in the future.
In general, is your approach applicable to discrete quantum systems? In particular, can you apply it directly to two-dimensional Fermi-Hubbard models?
Good question. It seems unlikely to us that the unadjusted sampling approach would be useful in discrete quantum systems, since the equivalent of a step size, which can be reduced to reduce bias, is lacking. We emphasize that our method is a replacement for Hamiltonian (Hybrid) Monte Carlo, which works for continuous systems. So applications to Hubbard models would require a continuous version of the system.
Do you always have the possibility to estimate bias in your calculation if you don't have a ground truth to compare against?
See above, but yes!
Summary
We would like to ask the reviewer to consider a higher score in light of our responses. In particular, we want to highlight two ways in which this work is really impactful:
- Hybrid Monte Carlo is a workhorse of many-body quantum physics (especially lattice gauge theory, but also in condensed matter, see e.g. https://www.nature.com/articles/s41467-023-37686-4), but is very computationally intensive. Our results represent a leap forward in efficiency, especially regarding the scaling with dimension we exhibit (figure 5).
- Black-box unadjusted MCMC methods are not yet widely used in applied stats: this paper provides valuable evidence that they scale to challenging and high dimensional problems, and especially that their bias is (a) detectable and (b) controllable
Comments on the paper
1 comment
Discussion period ending soon
Hi Reviewers,
The discussion period ends August 3. Please respond to the authors' rebuttal on whether or not your concern(s) have been addressed.
Thanks!
AC
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Rebuttal
Many thanks for this careful and thorough review. Our sense is that the reviewer’s most serious concerns are as follows:
Regarding (1), we are in agreement with the reviewer that “The main novelty therefore seems to be the adaptation and empirical validation in a QMC spin-fermion setting, rather than a new general-purpose MCMC algorithm”. The point is well-taken that this should be more clearly emphasized (although we do feel that we explicitly mention what we use from arXiv:2412.08876).
In terms of what is novel here relative to the recent papers on unadjusted samplers, the main point (other than the quantum setting, with pseudofermions, etc) is the introduction and analysis of bϵ (demonstrating that it is a good proxy for the true bias), the analysis of the bias as a function of step size (figure 4), and the analysis of the efficiency as a function of dimension (figure 5). The last of these has been studied for product distributions in previous work, but this case (where the efficiency of the unadjusted method is system size independent) constitutes a much more interesting case.
The are also a couple of facets of the bias analysis that we omitted from the current version in order to focus on the application, but which may be of interest. The first is a version or R^ to measure asymptotic bias, motivated as follows:
The second measure is inspired by the standard R^, which takes M chains and compares within-chain variance to across-chain variance. The idea is to measure initialization bias, since the MC variance of fully equilibrated chains should be identical at zero bias, hence across chain variance should also resemble within-chain variance and a quotient R^>1.05 is typically considered a sign of poor initialization. We propose a variation, where we run M chains with step-size ϵ to collect N samples, and M additional chains at ϵ/2 for double the number of samples. We then compute R^ for these 2M chains. We term this measure of asymptotic bias R^D. If the statistics of the ϵ/2 chains is similar to the ϵ chains, R^D should be close to R^, and below 1.05.
To our knowledge, R^d is novel; we omitted it since we view bϵ as a more direct measure of discretization error, but mention it here, since it may be of statistical interest. It remains below 1.05 throughout (across λ values at L=64,Nτ=40) and is at its maximum at the critical point.
One final facet of the bias analysis that we’d like to highlight, which we also didn’t include in the submitted version of the paper, is that we can perform a Bayesian analysis to extract the bias as a function of system size L and control parameter λ. Concretely, we treat each MCMC estimate of χ0 at a given (L,λ) as a datapoint yi, and fit a model jointly on the unadjusted and adjusted data:
where g and b are splines, and where b vanishes for adjusted HMC. This allows us to extract both the true expectation of χ0 more accurately, and the bias as a function both of step size (by inferring p) and system size. We will re-include this analysis in the paper, and are happy to discuss it further (Neurips rebuttals are not meant to contain external links unfortunately, so we can’t share a notebook).
Regarding (2), we are happy to add more discussion on this front to the paper. The short summary would be that the key factor in improving efficiency is to remove MH. Other factors, like the tuning of the mass matrix, and the preconditioning for CG, are kept fixed across the baseline and the unadjusted methods. The difference between the MCLMC and LMC dynamics is shown to be quite minimal (see e.g. figure 2).
Regarding (3), our plan to address the various clarity issues is as follows:
Other questions
The Fourier mass-matrix is used in https://arxiv.org/abs/2204.14241, but in the context of an adjusted sampler. The pseudo-rejection is used in practice in implementations of uMCLMC such as in https://github.com/blackjax-devs/blackjax. The bϵ measure, its comparison to ba, and the application to a QMC problem are all novel.
This is well observed since in principle the uncertainty intervals should be increased by the discretization bias, which is not included in the sample variability. However, the point here is that the discretization bias should be small compared to the variance, so that it can be neglected in the uncertainty intervals (which are not estimated exactly anyways, due to the initialization bias, which is also neglected). Checking that the Initialization bias is small requires examining diagnostics like Gelman-Rubin R-hat.
Great question. We have run an additional simulation at Nτ=80. For large Nτ we expect a worse scaling than with large L. But at Nτ=80, results do not get worse. Results are as follows (λ=3.0 result for MCLMC still underway):
This suggestion is in the spirit of Richardson extrapolation and related techniques, where the idea is that assuming some analytically known scaling of the bias with the stepsize, the result can be extrapolated to the zero step size. We have explored this approach, but found that the issue is that the bias as a function of stepsize depends on the target distribution. It typically scales as a high power of stepsize in the limit of stepsize -> 0, for example squared bias scales as the fourth power of the stepsize for Gaussian target distribution, but the exact form can vary, so the extrapolation does not work well in general.
We’re happy to make that change.
Summary If the reviewer is satisfied with these responses, we’d like to ask them to consider a change of score for the following reasons:
We have explored lower temperature behaviour of the model, as requested