Equivariant Force Field Calibration for Flow-based Protein Design
Fang Wu
NeurIPS 2026
Abstract. Flow models show promise for molecular design due to their fast, expressive sampling capabilities. However, their applicability to complex biological systems remains limited by a lack of physical grounding, which leads to unrealistic or unstable molecular structures. This work presents a framework that integrates force field guidance with consistency-based training to improve the physical fidelity of flow-based generative models. We calibrate pretrained flow models using differentiable physical energy functions to steer generation toward low-energy and sterically valid conformations. A consistency-based training strategy enables accurate, robust generation with very few sampling steps, improving inference efficiency. We evaluate it on three protein design tasks: unconditional backbone generation, full-atom peptide binder co-design, and antibody CDR-H3 redesign. Experiments show that our approach consistently improves physical plausibility and geometric stability, while enabling favorable trade-offs between structural diversity and computational cost. By unifying physical calibration and efficient sampling, we advance the scalability and reliability of flow-based molecular generation.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:44 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper presents FFC, a method that calibrates a pretrained flow model toward physically valid conformations by aligning its terminal velocity to a differentiable force-field gradient, coupled with a consistency-based training strategy for few-step sampling; it is evaluated on unconditional protein, peptide, and antibody design. Reviewers agree the central idea is interesting, applying the force field at the terminal state neatly sidesteps the problem of scoring non-physical intermediate objects. The disagreement is about theoretical rigor and evaluation completeness. I recommend the authors to address the following problems:
-
Absence of baselines (especially other force field guidance methods). Two reviewers flagged that experiments compare only FFC vs. no-FFC on each base model. However, the introduction of this paper mentioned a lot of related force field guidance / calibration methods. Even though the results in the paper looks good, it is unclear whether the proposed FFC method is better than prior related work. Also, the unconditional protein backbone generation doesn't have any baseline (unless I missed it). Besides absolute performance, the authors should also report sampling efficiency of FFC and compare with previous energy guidance methods.
-
There seem to be some problems in the derivation of FFCs (as flagged by two reviewers). Also, it's unclear whether the consistency flow is learned first and then calibrated ("once the consistency-regularized flow is learned…") or jointly optimized, and a reviewer raises a specific failure mode: the consistency loss merely tracking the teacher while calibration independently adjusts the endpoint.
Final justification
All reviewers have read authors response. Two reviewers remain very positive of the paper, while one reviewer had opposite view. AC has gone through the author response and found that authors have provided sufficient comparison with other guidance methods during rebuttal and additional baseline. While some minor issues remain, the main concern have been addressed. Therefore, AC recommends acceptance.
Read meta-review
Meta-review
This paper presents FFC, a method that calibrates a pretrained flow model toward physically valid conformations by aligning its terminal velocity to a differentiable force-field gradient, coupled with a consistency-based training strategy for few-step sampling; it is evaluated on unconditional protein, peptide, and antibody design. Reviewers agree the central idea is interesting, applying the force field at the terminal state neatly sidesteps the problem of scoring non-physical intermediate objects. The disagreement is about theoretical rigor and evaluation completeness. I recommend the authors to address the following problems:
-
Absence of baselines (especially other force field guidance methods). Two reviewers flagged that experiments compare only FFC vs. no-FFC on each base model. However, the introduction of this paper mentioned a lot of related force field guidance / calibration methods. Even though the results in the paper looks good, it is unclear whether the proposed FFC method is better than prior related work. Also, the unconditional protein backbone generation doesn't have any baseline (unless I missed it). Besides absolute performance, the authors should also report sampling efficiency of FFC and compare with previous energy guidance methods.
-
There seem to be some problems in the derivation of FFCs (as flagged by two reviewers). Also, it's unclear whether the consistency flow is learned first and then calibrated ("once the consistency-regularized flow is learned…") or jointly optimized, and a reviewer raises a specific failure mode: the consistency loss merely tracking the teacher while calibration independently adjusts the endpoint.
Final justification
All reviewers have read authors response. Two reviewers remain very positive of the paper, while one reviewer had opposite view. AC has gone through the author response and found that authors have provided sufficient comparison with other guidance methods during rebuttal and additional baseline. While some minor issues remain, the main concern have been addressed. Therefore, AC recommends acceptance.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This work proposes FFC, which integrates force field guidance with a pretrained flow model to steer generation toward low-energy and sterically valid conformations. A consistency flow model is learned from a pretrained flow model followed by the force field calibration where a differentiable reward model is used for gradient-based calibration of the terminal velocity. Experiments are conducted for unconditional protein design, peptide design and antibody design.
Strengths and weaknesses
The paper addresses an important need of current generative models for biological sequence/molecule design, which is the integration of physically grounded constraints into the training and generation process.
However, in its current state the paper has still some weaknesses that I will discuss below.
On the one-step vs. two-step training regime of the consistency loss and the calibration loss. In line 163 it is written “Once the consistency-regularized flow is learned...”, but in the next paragraph the authors state that they jointly optimize over the consistency and calibration loss (Line 167). Please clarify what training regime was used; and consider providing an ablation over the training dynamics.
In general, the trajectory gets shaped such that the terminal velocity sits in a good place for calibration, rather than the calibration fighting a fixed trajectory at the very end. I believe this would only work with the joint loss (line 167) and not be a subsequent optimization (line 163). The failure mode on the other hand would be that the consistency loss just adheres closely to the teacher dynamics and the calibration loss independently works on the endpoint velocity. Is there any reason to assume that this is not the case? Please clarify and discuss this further.
In line 171, the authors write on the equivariance of the calibration loss, which in Theorem 2.1 is shown to give an invariant loss under the assumption that vθ is invariant. If I am not mistaken, this property is already given by the model architecture (eg FrameFlow is SO(3)-equivariant by construction), not by FFC, so I would appreciate a discussion on what this theorem adds beyond what the pretrained base flow model already gives us.
In Table 1 first row, first column for 10 timesteps the increase using FFC is not 0.47 but 0.13 (and in Line 293). This is a discrepancy and needs to be clarified to avoid false statements.
Line 72-73: please provide some example references and state the domain that the claim holds for.
The ablation in Section H App. suggests that the setup is very sensitive wrt , which controls the influence of the force field model. This should be discussed in more detail, also in the main paper.
Please correct me if I missed it, but is there an ablation or experiment to dissect which of the components (consistency vs. force field calibration) does the heavy lifting and yields the performance boost? One would imagine it is the calibration loss. If this is the case, is it then also possible to isolate it and apply it to a pretrained flow model without the separate consistency model or a few-step model in general?
An ablation on regressing the terminal velocity only could also be very useful to convince the reader that this is sufficient. It could be compared to taking the last steps of the trajectory (at the cost of backpropagating through them).
Questions
I recommend the authors focus on the following points:
- Training regimes of one-step vs. two-step discrepancy
- Detailed ablations on consistency vs. calibration, as well as evaluating the sufficiency of the terminal velocity for the calibration loss
- Metrics reporting, wrt discrepancy of the increase by FFC (Table 1)
- Theorem 2.1. equivariance clarification
Limitations
Yes
Final justification
I thank the authors for their detailed responses. They have addressed my questions and concerns where possible given the timeframe of the rebuttal period. I appreciate the authors' commitment to revising some of their claims and updating Table 1 accordingly. I will take these responses and promised updates into account during the final discussion.
Formatting concerns
None that I noticed.
2 comments
Response to Reviewer 6bL9 (Sec 2)
Moderate force supervision improves physical quality, whereas excessive force strength overwhelms the learned generative prior and degrades geometry. is therefore a task-level calibration hyperparameter rather than a universally transferable constant.
We will move this discussion into the main text and avoid describing the method as broadly robust without qualification.
7. Which component does the heavy lifting?
Is the improvement mainly caused by calibration, and can calibration be isolated from consistency?
The existing one-step ablation shows:
- consistency-only versus base: validity +5.23, AAR +1.91, RMSD −0.34 Å, stability +0.53;
- joint FFC versus consistency-only: validity +7.17, AAR +4.55, RMSD −0.53 Å, stability +2.61;
- joint FFC versus base: validity +12.40, AAR +6.46, RMSD −0.87 Å, stability +3.14.
This indicates that force calibration supplies the larger share of the observed one-step physical-quality gain, while consistency alone also improves few-step generation.
The submitted experiments do not contain a clean calibration-only without consistency row. We will therefore not fabricate that result. We will state this as an important missing ablation and, if completed during rebuttal, report it separately with its exact training protocol.
8. Is terminal-only regression sufficient?
Compare terminal-only calibration with differentiating through the last few trajectory steps.
We agree that this is a valuable diagnostic. The submitted manuscript does not contain a controlled last--step backpropagation experiment, so we will not insert unsupported numbers.
Our present evidence supports only the narrower practical claim: terminal calibration plus joint consistency improves one-step and multi-step sampling without differentiating through the ODE trajectory. For example:
| Steps | Base validity | FFC validity | Base RMSD | FFC RMSD |
|---|---|---|---|---|
| 1 | 19.08 | 31.48 | 3.76 | 2.89 |
| 2 | 26.72 | 34.92 | 3.53 | 2.64 |
| 5 | 29.59 | 38.66 | 3.43 | 2.41 |
| 10 | 33.10 | 41.83 | 3.02 | 2.17 |
| 200 | 40.27 | 56.83 | 2.07 | 1.97 |
FFC improves validity at every sampling budget by 8.20–16.56 percentage points and lowers RMSD by 0.10–1.02 Å. These results demonstrate effectiveness, but they do not establish optimality relative to last--step differentiation.
9. Revised description of consistency
We will avoid saying that consistency “provably transports” the force correction backward. The revised explanation is:
- directly supervises the terminal physical target;
- regularizes trajectory-paired predictions of the same student;
- joint optimization empirically produces better one-step and multi-step samples than either the uncalibrated base or consistency-only training;
- no theorem is claimed for exact backward propagation of the terminal correction.
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 4/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 4/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper introduces a technique (FCC) to align a pretrained flow-matching model to a physical energy function. This is done by regressing the terminal velocity function to a force-field model and interleaving training with a consistency loss. The paper evaluates the method on unconditional protein design, peptide design, and antibody design fine-tuning 3 different models and comparing with and without FCC. The authors show improved performance in all three tasks.
Strengths and weaknesses
Overall, I thought this paper was very good and warrants acceptance. I thought aligning the terminal velocity to the force field was quite clever: I would expect the force-field to most accurate near a terminal state of the flow-matching process, and by aligning only at the terminal state, this approach should get around the problem of applying a force-field to a non-physical object. The rest of the method builds on prior work, and the results are quite strong.
There are some minor weaknesses of the paper. The theoretical section largely provides intuition and it’s not clear how well the argument holds when u* and q_t* are not accessible. Empirically, there is a fairly consistent decline in diversity with FCC that are not fully explored. I am also curious how well FCC compares to RL (or related methods) of a flow-matching model on an energy function. Specifically, I wonder how FCC compares to a method like AbFlowNet, which uses a GFlowNet on a similar problem.
Minor
- Equation 1 implies that an explicit, differentiable energy function is needed but that’s not true. Subsequent equations use a force-field
- It's unclear where the locally relaxed structure \tilde{x}_1 is used. This seems like a notational problem
- Shouldn't the force field in equation 2 be corrected to account for the relaxation step?
Questions
- A comparison between FCC and an RL or GFlowNet model.
- An analysis of why diversity falls for generated proteins.
Limitations
None were presented
Final justification
My assessment of this paper has not changed during the review period. Overall, I think this is a strong paper and while the other reviewers have pointed out some weaknesses in the presentation of the results, I don't think these issues change my view of the paper. Specifically, I am less concerned about the comparison against other methods on the presented tasks (pointed out by both me and reviewer 5iau), as I view the method in and of itself worthy of publication.
Formatting concerns
none
1 comment
Response to Reviewer Wrss
We thank the reviewer for the positive assessment and for recognizing why force-field supervision is most meaningful near a physical terminal state.
1. Inaccessible and
The theoretical argument is largely intuitive because and are inaccessible.
We agree. The theory is not a practical convergence guarantee. It provides an idealized interpretation conditional on a fixed reference field and path measure. The revision will explicitly state that:
- a terminal distribution does not identify a unique transport;
- the practical algorithm replaces with a force-corrected teacher target;
- terminal calibration plus consistency is a surrogate, not an exact solution of the ideal objective.
2. Comparison with RL or GFlowNet methods such as AbFlowNet
How does FFC compare with RL or GFlowNet optimization of an energy function?
The methods differ in their optimization object and assumptions:
| Approach | Optimized object | Reward use | Evaluator at inference | Main requirement |
|---|---|---|---|---|
| RL fine-tuning | policy over sampled trajectories | training | no | stochastic policy-gradient optimization |
| GFlowNet | reward-proportional terminal sampling | training | no | task-specific sequential construction graph |
| Inference-time force guidance | molecular state at each step | inference | yes | differentiable force calls during sampling |
| FFC | parameters of a pretrained flow/student | post-training | no | differentiable terminal guidance during calibration |
A direct numerical comparison with published AbFlowNet results would be confounded by the design task, action space, architecture, dataset, and reward. We will discuss AbFlowNet and related work as complementary approaches, but we will not present unmatched cross-paper numbers as a controlled comparison.
The controlled evidence currently available is the matched PepFlow comparison above. FFC outperforms energy conditioning, inference-time force guidance, idempotent guidance, and consistency-only training while retaining the base model’s 0.05 s/sample inference cost.
3. Why diversity decreases
There is a fairly consistent decline in diversity.
We agree that the manuscript should distinguish three effects:
- Denominator effect: normalized diversity divides cluster count by the number of designable samples, and FFC increases designability.
- Physical concentration: force calibration can concentrate samples in lower-energy regions.
- Few-step compression: consistency training may reduce variation at very small sampling budgets.
The absolute cluster counts provide a more nuanced picture:
- 10 steps: 124 121;
- 100 steps: 147 135;
- 500 steps: 123 126.
We will revise the claim to acknowledge a modest quality–diversity trade-off and include the absolute counts beside the normalized metric. The appendix sensitivity study already supports this interpretation: moderate force weights improve quality, whereas excessive force strength causes marked deterioration and changes the quality–novelty balance.
4. Eq. (1): energy versus force field
Eq. (1) suggests that an explicit differentiable energy is required, while later equations use a force field.
We agree. Eq. (1) is a motivating special case for a conservative field. The implemented regression only requires a vector-valued terminal guidance field. When , Eq. (1) admits an energy-reweighting interpretation. For a non-conservative learned guidance field, calibration remains possible, but the Gibbs-reweighting interpretation no longer applies.
5. Use of the relaxed terminal structure
It is unclear where is used.
We will use consistent Cartesian notation:
$ \widehat y_1=\zeta(\widehat z_1), \qquad \widetilde y_1 = \mathrm{sg}[ \mathrm{Relax}(\widehat y_1) ], $
$ \widetilde F_1 = \mathrm{NormalizeClip} [ F(\widetilde y_1) ],$
$y_{\mathrm{target}} = \mathrm{sg} [ y_{\mathrm{teacher}} + \lambda_F\widetilde F_1 ]. $
Relaxation is used only to obtain a numerically stable force target; no gradient is propagated through minimization.
6. Should Eq. (2) account for relaxation?
Yes. The practical target uses , not . We will correct Eq. (2) and the surrounding notation.
7. Limitations
We will add a visible limitations section covering:
- dependence on the fidelity of the force field or learned guidance;
- force-evaluation cost during calibration;
- sensitivity to ;
- the quality–diversity trade-off;
- the fact that classical force fields do not guarantee biological function or experimental binding;
- the absence of wet-lab validation.
- Rating
- 2/6
- Confidence
- 4/5
- Quality
- 2/4
- Clarity
- 2/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper studies flow models to generate protein sequences+conformations. The approach is named 'Force Field guided Calibration' (FFC). The idea is to 'fix/amend' the vector field of a flow model using a prior, e.g. the gradient of a molecular potential energy, so as to improve the quality of the designed molecules.
Strengths and weaknesses
The approach is interesting and the results appear very good.
Previous work is not adequately discussed. For example, ref [8] is not found in the main text. in addition, I do not understand why Table [5] qualifies it with No in the Training column.
From the theory standpoint, the presentation is sloppy and lacks rigor in many places, jeopardizing the overall piece of work.
Experiments do not compare against any competing method, nor do they explain why such a comparison is not feasible.
With a proper/rigorous presentation of the method and a benchmark against alternatives, this could be a great piece of work.
Questions
Theory
-
Smoothing forces in a pre-treatment. Eq.(4) is suspicious, as seen by considering the case of a single steric clash between atoms i and j. If ||F_i|| is huge, then the corrected \tilde F_i is close to 0. that is, the proposed correction appears to aggressive. please explain.
-
Eq (7): replace g(x_0,x_1) by the tangent to the geodesic.
-
In a nutshell, the losses used can be segregated into three groups: (1) the loss \calL_init (Eq. 8) which measures the discrepancy between v_\theta and the tangent to a geodesic joining two samples (2) the loss \calL_cfc for the total consistency flow calibration (3) the terminal calibration at t=1. please provide the pseudo-code for the back propagation, which is critical. as of now, understanding this back-propagation is very difficult.
-
Equation 10 appears to be false: plugging t=1 yields v_\theta = \bar{v}, which is not plausible.
-
Multi-modality flow on torsion angles. the expression \phi_t^{ang} cannot be correct since the ordering is not taken into account -- there are two paths joining two angles on S^1. also, using complex numbers, how come we do not have : phi^{ang} (t) = phi^{ang}(0) * exp( i * t(delta theta) )?
-
Function \zeta defining the 'differentiable reconstruction module'. the pseudo-code in SI show that this function returns coordinates, but the equation line 227 requires vectors -- as also requires by Eq. (8). your notations are not consistent.
-
Theoretical analysis. The assumption 2.2 states "there exists u^", which is fine. but proposition 2.3 does not mention which u^ is concerned !!!
Likewise, in Section 2.6, the text "in which u^* is recovered..." seems to imply u^* is unique, which is not the case.
In general in Section 2.6, the logical links between assumptions - equations - conclusion are not clear at all.
- Appendix : Table 6, L_prog is not defined.
Applications
-
The results look very good overall, congrats. but the lack of details makes it very hard to know what we are talking about.
-
Protein design. explain why the number of clusters is worse using FFC. also explain how the number of clusters is determined: is this some kind of 'elbow curve' criterion applied to backbones ? it would also be nice to have a 2D embedding based on MDS (using pairwise distances between backbones), to see whether these clusters make sense. as of now, interpreting this statistic is impossible.
-
Antibody design. are you processing single domain antibodies (6 CDRs), or nanobodies (3 CDRs)? this changes the size of the context. also, please define AAR and RMSD carefully.
For AAR, I assume you are talking about 'amino acid recall' or the like ? if so, this is a 'identity' rather than 'homology' statistic ? if this is the case, the 'homology' statistic obtained using a Blosum matrix is required. indeed, trading D for E or K for K (or H) is not significant. (NB: I am using 1 letter amino acid symbols).
For RMSD, I am assuming this is a RMSD computed on the (N, CA, C (O?)) atoms ? I guess it has to be so since the a.a. may have changed with respect to the CDR removed.
Finally, also report in SI the mutations observed.
Limitations
Yes.
Final justification
The paper was really too far from being polished, and there are too many promises in the changes foreseen. A journal submission with another serious review round is mandatory for me.
Formatting concerns
None.
6 comments
Response to Reviewer 5iau (Sec I)
We thank the reviewer for the detailed technical assessment and for noting that the approach is interesting and that the empirical results appear strong. We agree that the current presentation contains notation and rigor issues. We address each point below.
1. Related work and the “Training” column
Previous work is not adequately discussed. Ref. [8] is not found in the main text, and it is unclear why Table 5 marks it as “No” in the Training column.
We agree. Ref. [8] should have been discussed explicitly. We will add a focused comparison explaining that trajectory-level energy-guided methods differentiate an energy objective through the generative dynamics or an adjoint construction, whereas FFC constructs a stop-gradient, force-corrected terminal target and trains the flow parameters directly. FFC therefore avoids differentiating through the full ODE trajectory and requires no force-field calls at inference.
We will also replace the ambiguous Training column with four explicit attributes:
- whether generator parameters are updated;
- whether an auxiliary energy/reward model is trained;
- whether the physical evaluator is called during inference;
- whether trajectory-level differentiation or an adjoint solver is required.
The entry for Ref. [8] will be corrected under these definitions.
2. Comparison against competing methods
Experiments do not compare against any competing method.
We agree that this comparison was insufficiently highlighted. Table 3 already compares FFC against four matched alternatives using the same PepFlow backbone, same one-step sampling regime, and same evaluation set of 158 complexes:
| Method | Validity ↑ | AAR ↑ | RMSD ↓ | Stability ↑ | Time/sample ↓ |
|---|---|---|---|---|---|
| PepFlow | 19.08 | 40.27 | 3.76 | 10.69 | 0.05 s |
| + Consistency only | 24.31 | 42.18 | 3.42 | 11.22 | 0.05 s |
| + Inference-time forces | 22.47 | 41.63 | 3.51 | 12.84 | 1.52 s |
| + Idempotent flow | 26.15 | 43.91 | 3.28 | 11.87 | 1.46 s |
| + Energy conditioning | 28.52 | 44.85 | 3.08 | 12.43 | 0.07 s |
| + FFC | 31.48 | 46.73 | 2.89 | 13.83 | 0.05 s |
Relative to the uncalibrated model, FFC improves one-step validity by 12.40 percentage points, AAR by 6.46 points, RMSD by 0.87 Å, and stability by 3.14 points. Relative to the strongest competing one-step baseline, energy conditioning, FFC improves validity by 2.96 points, AAR by 1.88 points, RMSD by 0.19 Å, and stability by 1.40 points. Inference-time forces require 1.52 s/sample, approximately 30.4× the 0.05 s/sample cost of FFC.
We will move this table and its interpretation into the main comparison discussion. We will not claim a matched RL/GFlowNet comparison unless such a baseline is implemented under the same task, architecture, and reward.
3. Force normalization and Eq. (4)
For a very large force on one atom, the written correction appears to attenuate that force toward zero.
The reviewer is correct that the written equation is ambiguous and can be read as applying two magnitude-dependent attenuations. We will replace it with the exact implemented sequence:
,
followed by clipping in normalized space,
$ \widetilde F_i = F_i^{\mathrm{norm}} \min\left(1, \frac{c}{|F_i^{\mathrm{norm}}|+\epsilon} \right). $
Thus, the largest force is normalized to and then bounded; it does not converge toward zero merely because the original raw force is large. We will verify the manuscript equation against the released implementation and state the clipping threshold explicitly.
The existing robustness observation will also be stated more carefully: replacing per-structure normalization with a global normalization produced nearly identical performance in our implementation, but the manuscript should not imply invariance to arbitrary force preprocessing.
4. Eq. (7): tangent to the geodesic
Replace by the tangent to the geodesic.
We agree. A scalar geodesic distance cannot serve as a velocity target. The corrected objective is
where is the tangent of a shortest geodesic. For the modeled components, this becomes:
- Euclidean positions: ;
- rotations: ;
- torsions: the shortest wrapped angular displacement.
We will distinguish the geodesic distance , logarithm map , and tangent norm throughout.
Response to Reviewer 5iau (Sec II)
5. Complete backpropagation pseudocode
Please provide pseudocode for backpropagation.
FFC uses single-stage joint optimization:
Inputs:
trainable student v_theta
frozen/EMA teacher v_bar
differentiable reconstruction zeta
relaxation operator Relax
force evaluator F
For each minibatch:
1. Sample clean state z_1 and prior state z_0.
2. Sample 0 <= t < r < 1 and construct z_t, z_r
on the same teacher trajectory.
3. L_init = ||v_theta(z_0,0) - Log_{z_0}(z_1)||_g^2.
4. target_cot = stopgrad[v_bar(z_r,r)].
5. L_cot = w(t,r)||v_theta(z_t,t)-target_cot||_g^2.
6. Generate the student terminal state zhat_1.
7. yhat_1 = zeta(zhat_1).
8. yrelax_1 = stopgrad[Relax(yhat_1)].
9. Ftilde = stopgrad[NormalizeClip(F(yrelax_1))].
10. ytarget = stopgrad[yteacher_1 + lambda_F Ftilde].
11. L_cal = ||zeta(zhat_1)-ytarget||_g^2.
12. Update theta using
L = alpha_init L_init + alpha_cot L_cot + alpha_cal L_cal.
13. Update the EMA teacher, when used.
No gradient is propagated through the teacher target, relaxation, force evaluation, or pseudo-target construction. Gradients flow through the student and through on the student side of .
6. Eq. (10)
Eq. 10 appears false because setting gives an implausible conclusion.
We agree. Eq. (10) is incorrect as written and derive the algorithm, choose hyperparameters, or compute any reported result. Removing the erroneous bound therefore does not alter the method or empirical conclusions.
The revised paper will make only the following limited statement: because and optimize the same student parameters, joint training couples trajectory-paired predictions with terminal physical supervision. This is an empirical mechanism, not a formal guarantee that a terminal perturbation is analytically propagated backward.
7. Torsion-angle interpolation
The expression for does not account for the two paths on .
The corrected interpolation is $ \Delta \chi = \mathrm{wrap}_{[-\pi,,\pi)} (\chi_1-\chi_0 ). $ The angular interpolation is then
$\phi_t^{\mathrm{ang}} = \mathrm{wrap}_{[0, 2\pi)} (\chi_0+t \Delta \chi). $
Equivalently, $e^{i\phi_t^{\mathrm{ang}}} = e^{i\chi_0}e^{it\Delta\chi}. $
This selects a shortest wrapped displacement, except at the measure-zero antipodal ambiguity.
8. Reconstruction module : coordinates versus vectors
The pseudocode says returns coordinates, while the equations appear to require vectors.
We agree that the manuscript mixes a conceptual terminal-velocity interpretation with the practical Cartesian objective. In the implementation,
$ y_\theta=\zeta(z_{\theta,1}), y_{\mathrm{target}} = \mathrm{sg} \left[ y_{\mathrm{teacher}} + \lambda_F\widetilde F(\widetilde y_1) \right],$
and
$ \mathcal L_{\mathrm{cal}} = |y_\theta-y_{\mathrm{target}}|_g^2.$
Thus, maps multimodal latent variables to Cartesian coordinates. Gradients pass through the student-side Jacobian of to positions, orientations, and torsions. The teacher, relaxation, force, and pseudo-target branches are stop-gradient. We will clearly separate this implemented Cartesian displacement target from the motivating velocity-field description.
9. Existence and non-uniqueness of
Assumption 2.2 states only that a calibrated field exists, while Proposition 2.3 appears to imply uniqueness.
We agree. Multiple vector fields may transport to the same terminal distribution. The corrected proposition will be conditional:
Let be any fixed admissible reference field satisfying Assumption 2.2. Conditional on this chosen field and its path measure, the quadratic functional $ \mathcal L(v)=\frac{1}{2}|v-u^\star|_{\mathcal H}^2 $ has the unique minimizer .
This does not establish uniqueness of the transport associated with the energy-biased terminal distribution. We will remove “unique calibrated flow,” “recovers the calibrated flow,” and “rules out spurious minima” when describing the practical neural-network problem. The section will be retitled Idealized fixed-target regression interpretation.
10. Connection between the idealized theory and practical FFC
The logical links between assumptions, equations, and conclusions are unclear.
We explicitly distinguish:
| Idealized object | Practical surrogate |
|---|---|
| Fixed calibrated field | Force-corrected teacher terminal target |
| Path marginals | Teacher/student sampled trajectories |
| Full-path regression | Terminal calibration plus consistency regularization |
| Exact functional optimization | Neural-network SGD |
FFC is motivated by this regression view but is not mathematically equivalent to the inaccessible full-path objective. We will not claim exact recovery of or of the Gibbs-reweighted terminal distribution.
Response to Reviewer 5iau (Sec III)
11. Undefined
in Appendix Table 6 is undefined.
Thank you for catching this. denotes the progressive consistency-only baseline evaluated in the first row of Table 6. We will define it immediately before the table and use one name consistently.
For completeness, Table 6 reports:
| Loss setting | Val. AAR ↑ | Val. Rot. ↓ | Val. Trans. ↓ |
|---|---|---|---|
| Progressive only | 0.030 | 2.486 | 44.78 |
| 0.437 | 1.731 | 4.52 | |
| 0.133 | 1.880 | 4.56 | |
| 0.439 | 1.596 | 4.50 | |
| 0.430 | 1.627 | 4.58 | |
| 0.448 | 1.515 | 4.27 |
12. Protein-design clusters and diversity
Why is the number of clusters worse with FFC, and how are the clusters determined?
Table 1 reports both normalized diversity and the absolute number of structural clusters:
| Steps | Base designability | FFC designability | Base diversity (clusters) | FFC diversity (clusters) |
|---|---|---|---|---|
| 10 | 0.67 | 0.80 | 0.54 (124) | 0.43 (121) |
| 100 | 0.77 | 0.83 | 0.28 (147) | 0.26 (135) |
| 500 | 0.81 | 0.85 | 0.22 (123) | 0.21 (126) |
At 10 steps, the absolute cluster count changes only from 124 to 121 (), while designability rises from 0.67 to 0.80 ( relative). Therefore, much of the normalized-diversity reduction from 0.54 to 0.43 is a denominator effect: FFC makes more samples designable, and many additional designable samples fall into already occupied structural clusters.
At 500 steps, the absolute cluster count actually increases from 123 to 126, even though the normalized ratio changes from 0.22 to 0.21. At 100 steps, the absolute count decreases from 147 to 135, so a real concentration effect remains and should not be dismissed.
We will add the exact MaxCluster similarity metric, cutoff, and linkage setting used by the evaluation script, and we will revise the interpretation from “diversity is largely preserved” to the more precise claim:
FFC improves designability and novelty while inducing a modest quality–diversity trade-off; the decline is larger in normalized diversity than in absolute mode count.
We agree that an MDS visualization and matched-size cluster analysis would be useful supplementary diagnostics. We will include them only if completed and will not rely on unreported results in the rebuttal.
13. Antibody setting
Are the experiments on conventional antibodies or nanobodies?
The task is conditional CDR-H3 sequence–structure redesign, not simultaneous generation of all six CDRs or all three nanobody CDRs. The antigen, framework, and non-designed CDRs are provided as context; only CDR-H3 is masked and generated. We will state this explicitly in the setup to remove the ambiguity.
14. Definitions of AAR and RMSD
AAR measures identity rather than homology; please add a BLOSUM-based statistic and define RMSD precisely.
We agree. AAR is exact amino-acid recovery:
$ \mathrm{AAR} = \frac1L\sum_{i=1}^{L} \mathbf 1[ \widehat a_i=a_i^{\mathrm{native}} ]. $
It is an identity statistic, not a homology statistic. The existing antibody result is:
| Method | AAR ↑ | RMSD ↓ |
|---|---|---|
| UniMoMo-all | 52.34 | 1.04 Å |
| UniMoMo-all + FFC | 54.03 | 0.99 Å |
Thus, FFC improves exact recovery by 1.69 percentage points and lowers RMSD by 0.05 Å (4.8%).
We will add a BLOSUM-based similarity metric and a mutation matrix in the revision. We will not invent those values before the analysis is complete.
The RMSD definition will be stated directly from the evaluation script, including:
- the atoms used for alignment;
- the atoms included in the reported CDR-H3 RMSD;
- whether carbonyl oxygen is included;
- treatment of differing residue identities.
15. Mutations observed
Please report the mutations observed.
We agree. We will add the native-to-generated substitution matrix and summarize exact recovery, conservative substitutions, and non-conservative substitutions. Because these values are not present in the submitted manuscript, we will report them only after rerunning the evaluation, rather than filling them speculatively.
We thank the reviewer again for the detailed feedback and constructive suggestions, which definitely help us improve the quality of our manuscript during the rebuttal period. Importantly, these corrections affect the exposition, notation, and theoretical scope, but not the implemented training algorithm or the reported experimental results.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Response to Reviewer 6bL9 (Sec 1)
We thank the reviewer for identifying the central mechanism question: whether terminal calibration and consistency genuinely interact or merely optimize separate aspects of the model.
1. Single-stage versus two-stage training
The implementation uses single-stage joint optimization:
L=αinitLinit+αcotLcot+αcalLcal.
The phrase “Once the consistency-regularized flow is learned” is inaccurate and will be replaced by:
We will not claim results for sequential or alternating regimes unless those experiments are completed.
2. Could consistency imitate the teacher while calibration changes only the endpoint?
This is a valid concern. The current controlled one-step results already show that the joint method exceeds consistency-only training:
Relative to consistency-only training, adding terminal force calibration improves validity by 7.17 points, AAR by 4.55 points, RMSD by 0.53 Å, and stability by 2.61 points. Therefore, the result cannot be explained by consistency compression alone.
However, these numbers do not by themselves prove how far terminal supervision changes earlier-time predictions. We will therefore make the mechanism claim more modest:
3. What does the equivariance theorem add?
We agree. The theorem is a preservation result, not a source of equivariance. The corrected statement is:
The original text incorrectly referred to the vector field as invariant rather than equivariant. We will retitle the result Equivariance preservation under force-field calibration.
4. Incorrect +0.47 improvement
The reviewer is correct:
We will correct Table 1 and the accompanying text to +0.13, replace “relative improvements” with “absolute differences,” and audit all reported arithmetic.
The corrected designability gains are:
5. Reward-based alignment claim
We will replace the broad statement with the more precise claim:
We will add representative references from language-model alignment, diffusion/image alignment, and molecular reward optimization.
6. Sensitivity to λF
We agree, and this should be discussed in the main paper. The appendix currently reports:
These results show that FFC is not insensitive to force scaling. The defensible conclusion is: