Rethinking Visual Attribution for Chest X-ray Reasoning in Large Vision Language Models
Guangzhi Xiong, Qiao Jin, Sanchit Sinha, Zhiyong Lu, Aidong Zhang
NeurIPS 2026
Abstract. Large Vision Language Models (LVLMs) show promise in medical applications, but their inability to faithfully ground responses in visual evidence raises serious concerns about clinical trustworthiness. While visual attribution methods are widely used to explain LVLM predictions, whether these explanations actually reflect the visual evidence underlying the model's decision is largely unverified, since ground-truth annotations for internal model reasoning are typically unavailable. We address this question for chest X-ray (CXR) reasoning by developing a causal evaluation framework that retains only CXR-VQA samples for which the expert-annotated region is verified, via counterfactual editing, to be causally responsible for the model's prediction. Using this framework across 11 attribution methods, six open-source LVLMs, and two output modes (direct answer and step-by-step reasoning), we find that existing attribution methods often fail to identify the evidence used by LVLMs. To address this failure, we propose MedFocus, a concept-based attribution method that localizes clinically meaningful anatomical regions via unbalanced optimal transport and measures their causal effect on model outputs through targeted interventions. MedFocus produces spatial, concept-level, and token-level attributions and substantially outperforms prior methods, taking a step toward more trustworthy attribution for medical LVLMs. Our data and code are available at https://github.com/gzxiong/medfocus/.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:46 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
(a) Summary: The paper takes on a trust problem in medical vision language models, namely that their answers are often not actually grounded in the right visual evidence. It offers two contributions. First, MedGround-Bench, a causally validated CXR-VQA attribution benchmark that uses counterfactual image editing to check whether a prediction really depends on the clinically relevant region, and it uses this to show that 11 existing attribution methods often fail to point at the evidence driving the decision. Second, MedFocus, a concept-based causal attribution method that measures how much each anatomical region influences the output through targeted interventions, and returns pixel-, concept-, and token-level attributions with a single forward pass per concept. Experiments span three CXR datasets, several LVLMs, and both direct-answer and reasoning modes.
(b) Main strengths: Reviewers agree the problem is important and closely tied to clinical trust. Moving from correlation-based evaluation to a causal one built on counterfactual editing is seen as a solid methodological step. MedFocus is efficient because it relies on a single forward pass, which matters for real deployment, and attributing the reasoning trace at the token and concept level is a novel and interesting direction. The experimental setup is broad and well controlled, covering three datasets, multiple models, and a multi-step filtering pipeline that isolates whether the prediction is truly driven by the relevant region.
(c) Main weaknesses: A few concerns are shared across reviewers. The foreground/background split is oversimplified and may not handle diagnoses that need evidence from several regions or global cues such as cardiothoracic ratio, bilateral symmetry, or diffuse bilateral disease, and the causal filter may silently drop these cases. The evaluation also looks unfair to the baselines, since all pixel-level saliency maps are turned into boxes with a fixed 90th-percentile threshold, while MedFocus outputs a concept box directly, so the comparison is not on equal footing. The zero-masking intervention can add boundary artifacts and out-of-distribution patterns, so the model may react to image damage rather than to missing evidence, and gentler edits such as healthy-tissue inpainting or cross-disease replacement are not compared. Reviewers also flag a human-centric bias since faithfulness is anchored to human annotations, a possible finding-versus-anatomy mismatch in the IoU measurement, limited in-domain LVLM coverage, and that the binary VQA setup does not capture the full range of clinical reasoning.
(d) First, an evaluation-fairness check that shows whether MedFocus stays ahead when the baselines are allowed validation-tuned adaptive thresholds instead of a fixed one. Second, a comparison across intervention types (zero-masking versus healthy-tissue inpainting versus cross-disease replacement) to rule out results that are driven by masking artifacts rather than true removal of evidence. Third, some handling of the multi-region and global-cue cases, at least an analysis of how often they are excluded by the filter, plus per-region support and metrics. Clear answers on evaluation fairness and the intervention design would matter most.
Final justification
The paper makes a clear and clinically motivated contribution, and the benchmark and method are technically sound. All reviewers voted Accept or Weak Accept, and maintained their ratings after the rebuttal, which addressed the substantive concerns. The two remaining points (evaluation fairness under adaptive thresholds, and intervention design beyond zero-masking) are refinements to the evaluation rather than challenges to the core claims. I therefore recommend acceptance, and ask the authors to include these additions, along with the promised adaptive-threshold fairness check and intervention-type comparison, in the camera-ready.
Read meta-review
Meta-review
(a) Summary: The paper takes on a trust problem in medical vision language models, namely that their answers are often not actually grounded in the right visual evidence. It offers two contributions. First, MedGround-Bench, a causally validated CXR-VQA attribution benchmark that uses counterfactual image editing to check whether a prediction really depends on the clinically relevant region, and it uses this to show that 11 existing attribution methods often fail to point at the evidence driving the decision. Second, MedFocus, a concept-based causal attribution method that measures how much each anatomical region influences the output through targeted interventions, and returns pixel-, concept-, and token-level attributions with a single forward pass per concept. Experiments span three CXR datasets, several LVLMs, and both direct-answer and reasoning modes.
(b) Main strengths: Reviewers agree the problem is important and closely tied to clinical trust. Moving from correlation-based evaluation to a causal one built on counterfactual editing is seen as a solid methodological step. MedFocus is efficient because it relies on a single forward pass, which matters for real deployment, and attributing the reasoning trace at the token and concept level is a novel and interesting direction. The experimental setup is broad and well controlled, covering three datasets, multiple models, and a multi-step filtering pipeline that isolates whether the prediction is truly driven by the relevant region.
(c) Main weaknesses: A few concerns are shared across reviewers. The foreground/background split is oversimplified and may not handle diagnoses that need evidence from several regions or global cues such as cardiothoracic ratio, bilateral symmetry, or diffuse bilateral disease, and the causal filter may silently drop these cases. The evaluation also looks unfair to the baselines, since all pixel-level saliency maps are turned into boxes with a fixed 90th-percentile threshold, while MedFocus outputs a concept box directly, so the comparison is not on equal footing. The zero-masking intervention can add boundary artifacts and out-of-distribution patterns, so the model may react to image damage rather than to missing evidence, and gentler edits such as healthy-tissue inpainting or cross-disease replacement are not compared. Reviewers also flag a human-centric bias since faithfulness is anchored to human annotations, a possible finding-versus-anatomy mismatch in the IoU measurement, limited in-domain LVLM coverage, and that the binary VQA setup does not capture the full range of clinical reasoning.
(d) First, an evaluation-fairness check that shows whether MedFocus stays ahead when the baselines are allowed validation-tuned adaptive thresholds instead of a fixed one. Second, a comparison across intervention types (zero-masking versus healthy-tissue inpainting versus cross-disease replacement) to rule out results that are driven by masking artifacts rather than true removal of evidence. Third, some handling of the multi-region and global-cue cases, at least an analysis of how often they are excluded by the filter, plus per-region support and metrics. Clear answers on evaluation fairness and the intervention design would matter most.
Final justification
The paper makes a clear and clinically motivated contribution, and the benchmark and method are technically sound. All reviewers voted Accept or Weak Accept, and maintained their ratings after the rebuttal, which addressed the substantive concerns. The two remaining points (evaluation fairness under adaptive thresholds, and intervention design beyond zero-masking) are refinements to the evaluation rather than challenges to the core claims. I therefore recommend acceptance, and ask the authors to include these additions, along with the promised adaptive-threshold fairness check and intervention-type comparison, in the camera-ready.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes MedGround-Bench, a causally-validated CXR-VQA attribution benchmark, and MedFocus, a concept-based causal attribution method. The problem is important and the framework is well-structured.
Strengths and weaknesses
Strenths: The faithfulness of visual attribution in medical LVLMs is directly tied to clinical trustworthiness, making the problem highly significant.
Weaknesses:
- Foreground intervention is too crude: The paper uses zero-masking to blank out the target region, which introduces severe boundary artifacts and out-of-distribution patterns. The model may react to the destruction of image quality rather than the absence of evidence. Moreover, the paper does not adequately compare against gentler alternatives such as healthy-tissue inpainting, cross-disease replacement, or severity-/scale-aware editing.
- Foreground/background dichotomy is oversimplified: Clinical reasoning patterns such as cardiothoracic ratio, bilateral lung symmetry, and trans-lobar/trans-organ cues cannot be captured by this binary assumption. The causal filter may systematically exclude cases where the model relies on multi-region evidence.
- Evaluation pipeline raises fairness concerns: All pixel-level saliency maps are converted to bounding boxes using a fixed 90th-percentile hard threshold, without adapting to the very different saliency distributions across methods. MedFocus, by contrast, directly outputs a concept-level bounding box, bypassing thresholding and connected-component analysis. This inconsistency undermines the claim that MedFocus is strictly superior.
Questions
-
Intervention design: Can the authors provide a comparative attribution study across zero-masking, healthy-tissue inpainting, cross-disease replacement, and fine-grained editing, to rule out the possibility that the model is responding to black-box artifacts rather than true semantic removal?
-
Multi-region and global cues: How does the foreground/background assumption handle diseases whose diagnosis requires simultaneous evidence from multiple anatomical regions or global cues (e.g., cardiothoracic ratio, bilateral symmetry, diffuse bilateral disease)?
-
Evaluation fairness: Would MedFocus remain superior if baseline methods used validation-set-tuned adaptive thresholds?
Limitations
Yes
Final justification
I thank the authors for their detailed response. Since my main concerns have been addressed, I recommend acceptance.
Formatting concerns
No
1 comment
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors propose an evaluation framework and method for visual attribution for chest X-Ray analysis and reasoning with Large Vision-Language Models. Using their evaluation framework they first show that existing attribution methods fail to identify the causally relevant regions in the image and then propose MedFocus, a concept-based attribution method that uses anatomical regions in the Chest X-ray as concept and outputs attributions on a pixel-, concept- and token-level.
Strengths and weaknesses
The authors address a relevant problem of trying to assess whether the response of an LVLM about a given X-Ray is actually grounded in the correct anatomical region. They make clever use of the extensive annotations for chest X-Rays and off-the-shelf image editing models to create targeted counterfactuals that causally affect the models' predictions. In addition to the investigation of feature attribution in a simple finding VQA setting with a direct answer, the authors also explore how the final decision can be attributed to the step-by-step reasoning trace. Attributing this trace on a token- and concept-level is novel and an intriguing research direction that is also clearly motivated in the paper. The experimental validation of the claims is evaluated on 3 chest X-ray datasets, with 2 general purpose LVLMs and one domain-specific one and includes relevant baselines, meaningful experiments and extensive quantitative and qualitative results.
While the method is well motivated, executed and cleary presented, I see some concerns in the setup that need to be adressed:
Region mismatch between findings and anatomy The bounding boxes of e.g. ImaGenome are describing general anatomical regions not clinical findings. Therefore, IOU measurements against them might be misleading since a narrower attribution for a given finding might be more accurate but lead to lower IOU values? From my understanding the compared attribution methods are more granular / on a pixel level but in MedFocus regions are simply defined by the same anatomical concepts (and segmented with MedSAM) that the attribution is measured against.
Choice of LVLMs Despite a series of available LVLMs that have been trained on X-rays (CheXagent-2, MedVersa, Lingshu etc.), only two MedGemma variants are included and 2 general purpose LVLMs that obviously struggle with interpreting X-rays (see Table 4). The experimental evaluation would be stronger if at least one more in-domain LVLM is added to the evaluation.
Trivial anatomy mapping For most findings in chest X-rays the attribution to an anatomical region is trivial (e.g. cardiomegaly -> cardiac silhouhette). Furthermore, the vast amount of findings are located in either the left or right lung. Given the low number of correct & grounded samples, it would be important to see the support and metrics per region.
Questions
- Could you break down the support by anatomical region in MedGround-Bench?
- Can you provide a qualitative overview where the mapping from finding to anatomy is non-trivial?
- Is IOU measured against finding or anatomy bounding boxes?
- Is there a methodological bias in that MedFocus is inherently aligned with the GT reference by design? Could alternative metrics be used?
Limitations
The limitations were addressed appropriately, but the limitations of a single forward pass for token-level attribution could be added here.
Final justification
I raised my score since the majority of my questions have been resolved in the rebuttal. As noted in the comment below, some concerns remain, but the authors want to address them further in the final version.
Formatting concerns
None
3 comments
Rebuttal
Thank you for the detailed and constructive review. Below we provide point-by-point responses to each of your concerns.
(W1) The bounding boxes of e.g. ImaGenome are describing general anatomical regions not clinical findings. Therefore, IOU measurements against them might be misleading since a narrower attribution for a given finding might be more accurate but lead to lower IOU values? From my understanding the compared attribution methods are more granular / on a pixel level but in MedFocus regions are simply defined by the same anatomical concepts (and segmented with MedSAM) that the attribution is measured against.
(Q3) Is IOU measured against finding or anatomy bounding boxes?
While we adopted the official bounding boxes from the datasets, we agree that the coarse-grained anatomical boxes from ImaGenome may penalize a narrower but clinically valid attribution under IoU (measured against the bounding boxes). In such scenarios, the precision metric could be a more robust measure of faithfulness than IoU, which is reported in our existing results as well. In Table 1 of our paper, we have reported IoU, F1, precision, and recall for each method, providing a comprehensive evaluation from multiple perspectives. Below we present the detailed precision comparison of different methods on the ImaGenome dataset. Although the compared attribution methods could be more granular / on a pixel level, they do not achieve high precision. Instead, MedFocus achieves the highest average precision and the best precision on more LVLMs than any single baseline, given its concept-level attribution, indicating better attribution quality than the compared baselines. We will add this discussion to the revised paper to clarify the slightly different focus of different evaluation metrics across datasets given their different granularity.
| Model | Attention Head | GradCAM | Occlusion | MedFocus |
|---|---|---|---|---|
| Qwen2.5-VL-3B | 62.73 | 62.31 | 71.10 | 70.62 |
| Qwen2.5-VL-7B | 45.66 | 63.96 | 59.72 | 65.07 |
| Gemma3-4B | 30.20 | 57.36 | 31.63 | 54.93 |
| Gemma3-12B | 27.46 | 36.70 | 46.40 | 57.99 |
| MedGemma-4B | 51.38 | 39.84 | 52.21 | 65.65 |
| MedGemma1.5-4B | 54.18 | 54.17 | 68.75 | 65.21 |
| All | 49.27 | 48.99 | 58.06 | 64.65 |
(W2) Despite a series of available LVLMs that have been trained on X-rays (CheXagent-2, MedVersa, Lingshu etc.), only two MedGemma variants are included and 2 general purpose LVLMs that obviously struggle with interpreting X-rays (see Table 4). The experimental evaluation would be stronger if at least one more in-domain LVLM is added to the evaluation.
Following your suggestion, we add Lingshu-7B, an in-domain medical LVLM fine-tuned from Qwen2.5-VL-7B. Using the same filtering pipeline as MedGround-Bench-Direct, we retain 303 samples for evaluation (ImaGenome 172, VinDR-CXR 41, PadChest-GR 90). The table below compares the filtering-stage distribution against Qwen2.5-VL-7B (the base model from which Lingshu-7B was fine-tuned), merged across the three datasets. As an in-domain medical model, Lingshu-7B produces more correct and causally grounded answers than the general-purpose Qwen2.5-VL-7B.
| Model | Incorrect (%) | Correct & Ungrounded (%) | Correct & Grounded (%) |
|---|---|---|---|
| Qwen2.5-VL-7B | 75.3 | 22.4 | 2.3 |
| Lingshu-7B | 66.3 | 28.8 | 4.9 |
After the data construction for Lingshu-7B, we evaluate the attribution performance of MedFocus and the baselines on the retained samples to see if they can faithfully explain how Lingshu-7B makes its predictions. The results show that MedFocus presents the best overall performance, consistent with our findings across the original six models.
| Dataset | Method | IoU | F1 | Precision | Recall |
|---|---|---|---|---|---|
| ImaGenome | Attention Head | 9.96 | 17.43 | 37.42 | 11.73 |
| GradCAM | 8.87 | 15.39 | 42.19 | 11.04 | |
| Occlusion | 23.67 | 37.03 | 70.17 | 26.78 | |
| MedFocus | 64.83 | 77.23 | 70.49 | 90.60 | |
| VinDR-CXR | Attention Head | 8.27 | 14.51 | 16.38 | 21.95 |
| GradCAM | 13.31 | 21.55 | 37.09 | 21.49 | |
| Occlusion | 20.12 | 31.58 | 35.52 | 47.45 | |
| MedFocus | 26.66 | 38.36 | 29.75 | 91.64 | |
| PadChest-GR | Attention Head | 10.15 | 16.60 | 27.88 | 14.40 |
| GradCAM | 13.15 | 21.13 | 38.95 | 17.44 | |
| Occlusion | 25.02 | 37.78 | 61.38 | 33.06 | |
| MedFocus | 37.34 | 50.67 | 50.06 | 70.83 |
(W3.1) For most findings in chest X-rays the attribution to an anatomical region is trivial (e.g. cardiomegaly -> cardiac silhouhette).
(Q2) Can you provide a qualitative overview where the mapping from finding to anatomy is non-trivial?
We would like to clarify that while a mapping such as "cardiomegaly → cardiac silhouette" sounds trivial for humans based on its semantic meaning, it is non-trivial for the LVLM to truly rely on that exact region for its medical reasoning, and for an attribution method to faithfully recover the model's attention. The table below reports the number of "cardiomegaly" questions in each source dataset and how many are retained after the causal filtering during benchmark construction. Across the three datasets, only about 12–22% of the cardiomegaly questions survive causal filtering, showing that a semantically trivial mapping does not imply that the LVLM is correct and actually grounds its prediction on the annotated "cardiac silhouette" region.
| Dataset | Count in source | Count in retained |
|---|---|---|
| ImaGenome | 121 | 15 |
| VinDR-CXR | 309 | 52 |
| PadChest-GR | 191 | 41 |
| All | 621 | 108 |
Moreover, even on the retained samples where the model is causally validated to rely on the "cardiac silhouette" region, the compared attribution methods may still fail to faithfully reflect it. Below we report the performance of MedFocus on the retained cardiomegaly samples, with comparison to the baseline methods. The results show the attribution of model predictions on cardiomegaly is non-trivial, and MedFocus shows superior IoU/F1 to the baselines on such cases.
| Method | IoU | F1 | Precision | Recall |
|---|---|---|---|---|
| Attention Head | 19.12 | 29.79 | 32.57 | 31.85 |
| GradCAM | 17.91 | 28.80 | 30.26 | 63.48 |
| Occlusion | 28.50 | 41.17 | 50.79 | 46.84 |
| MedFocus | 31.31 | 45.13 | 38.45 | 70.28 |
Following your suggestion, we will also add qualitative examples for "pleural effusion", whose ground-truth evidence annotation varies markedly across samples, highlighting how MedFocus and the other methods differ in their attribution results.
(W3.2) Furthermore, the vast amount of findings are located in either the left or right lung. Given the low number of correct & grounded samples, it would be important to see the support and metrics per region.
(Q1) Could you break down the support by anatomical region in MedGround-Bench?
Following your suggestion, we break down the attribution performance by anatomical region on ImaGenome. Below, we report IoU by anatomical region. The results show that the performance across regions is relatively consistent for each method, and that MedFocus outperforms the baselines on all regions.
| Method | lung (n=767) | hilar (n=289) | costophrenic (n=205) | cardiac (n=35) |
|---|---|---|---|---|
| Attention Head | 16.14 | 17.32 | 16.87 | 20.27 |
| GradCAM | 29.04 | 30.18 | 29.65 | 22.74 |
| Occlusion | 24.00 | 25.96 | 26.96 | 39.10 |
| MedFocus | 55.32 | 61.56 | 56.32 | 45.39 |
(Q4) Is there a methodological bias in that MedFocus is inherently aligned with the GT reference by design? Could alternative metrics be used?
We agree that MedFocus has an inductive advantage on ImaGenome because its anatomical concept vocabulary partially overlaps with the dataset's annotation ontology. However, MedFocus does not access the ground-truth boxes or RadEdit masks at inference time. Moreover, it also outperforms the baselines on VinDR-CXR and PadChest-GR, whose annotations do not share ImaGenome's box definitions. These results suggest that the improvement is not solely explained by ontology alignment. To reduce dependence on any single localization measure, we reported IoU, precision, recall, and F1, which capture complementary aspects of attribution quality.
(Limitation) [...] the limitations of a single forward pass for token-level attribution could be added
Thank you for the suggestion. We will add a brief note to the Limitations. By design, the token-level attribution is computed within MedFocus's single forward pass conditioned on the model's originally generated sequence. This is an efficient and informative local measure, consistent with how standard attribution methods operate. As with other local methods, it does not re-decode the sequence under each intervention, and extending it with regeneration-based or multi-sample sequence attribution is a natural direction for future work.
Thank you for the detailed rebuttal. The addition of another medical LVLM has improved the paper's experimental strength, and exposing that models fail even with trivially correlated anatomical grounding indeed demonstrates the method's effectiveness. This, along with the additional experimental results, resolves the majority of my concerns. I still think the method has an inductive advantage in that it builds on concepts rather than pixel-based methods, regardless of the dataset used. I would also note that the concepts used are limited to anatomical regions and do not capture the finer clinical descriptors that a radiologist would use to ground pathologies in an image.
Thank you for your engagement and thoughtful follow-up. We are glad that our rebuttal "resolves the majority of" your concerns, and would like to provide the following clarifications on the remaining points.
We agree that our MedFocus has an inductive advantage over pixel-based methods, and this is a deliberate design choice for better alignment with human understanding. Regarding evaluation, concept-level attribution can be an advantage or disadvantage depending on the granularity of the ground-truth annotation. For example, in our main experiments (Table 1), MedFocus shows lower precision on VinDR-CXR and PadChest-GR than on ImaGenome because these datasets provide finer-grained finding-level annotations, closer to the "finer clinical descriptors" you mentioned, but MedFocus still provides more precise attribution than most baselines and shows the highest IoU/F1 scores.
Additionally, MedFocus is proposed as a general framework whose concept vocabulary is not limited to anatomical regions. As discussed in the "Vocabulary granularity" paragraph of Appendix D, the vocabulary can be expanded with finer clinical concepts for more detailed grounding. Given your remaining concern, we will make this extensibility more prominent in the revised paper, noting the limitations of the current anatomical-region-based implementation and describing its extension to finer-grained concepts as a future direction.
Thank you again for your constructive feedback and for recognizing our concept-level attribution method as "novel and an intriguing research direction that is also clearly motivated". We hope these clarifications resolve your remaining concerns.
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 4/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 4/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper introduces three main contributions to enhance the trustworthiness of medical Large Vision Language Models (LVLMs):
- MedGround-Bench: The creation of a causally-validated evaluation framework that uses counterfactual image editing to ensure a verifiable link between anatomical evidence and model predictions.
- Empirical Demonstration of Failure: A systematic evaluation of 11 existing attribution methods showing they fail to faithfully identify the evidence driving medical AI decisions.
- MedFocus Implementation: A novel concept-based attribution method that achieves superior faithfulness by measuring the causal influence of anatomical regions through targeted interventions. This approach is notably efficient, utilizing a single forward pass per concept to quantify how specific visual evidence contributes to the model's output, effectively isolating causal influence without the computational overhead or sampling noise of iterative or generation-based methods.
Strengths and weaknesses
Strengths
- Rigorous Causal Grounding: The transition from observational correlation to causal evaluation via counterfactual editing is a good methodological advancement for medical AI trust.
- Methodological Efficiency: MedFocus employs an elegant single forward pass intervention strategy, balancing attribution faithfulness with inference speed, which is critical for practical clinical deployment.
- Robust Experimental Design: The authors employ a comprehensive evaluation setup that spans three diverse CXR datasets (ImaGenome, VinDR-CXR, PadChest-GR), six varied LVLMs, and two distinct output modes, ensuring that the findings are not artifacts of a single model or dataset.
- Controlled Filtering Pipeline: The multi-step filtering process, which includes correctness, foreground editing, and background editing checks, provides a highly controlled environment to isolate whether a model's prediction is truly driven by the clinically relevant region.
Weakness -Human-Centric Bias (“Unknown Unknowns”): The framework evaluates faithfulness by anchoring explanations to human-expert annotations. This risks a "human-centric bias" where the AI’s potential to discover novel, non-human-observable features or more complex clinical patterns is penalized because they do not conform to predefined human annotations.
- Simplified Task Formulation: Evaluating models on binary VQA questions ("Is there evidence of X?") provides a controlled testbed but does not fully capture the complexities of real-world clinical tasks like nuanced radiology report generation or multi-step diagnostic reasoning.
Questions
Does your approach assumes 1:1 mapping of the disease/abnormal mapping of the bounding box? What if one diagnosis requires 3 out of 5 possible pathological changes?
What if the diagnosis uses overall structure like the shape of the lung?
What if there are other pathological findings that outside this bounding box but relevant/informative, either the annotator did not annotate or humans are not aware?
Limitations
yes
Formatting concerns
N/A
1 comment
Rebuttal
Thank you for the detailed and constructive review. Below we provide point-by-point responses to each of your concerns.
(W1) Human-Centric Bias ("Unknown Unknowns"): The framework evaluates faithfulness by anchoring explanations to human-expert annotations. This risks a "human-centric bias" where the AI’s potential to discover novel, non-human-observable features or more complex clinical patterns is penalized because they do not conform to predefined human annotations.
(Q3) What if there are other pathological findings that outside this bounding box but relevant/informative, either the annotator did not annotate or humans are not aware?
Thank you for the insightful comment. We agree that the benchmark is human-anchored and does not aim to exhaustively evaluate all potentially unannotated or non-human-interpretable evidence. Our filtering does not assume that the annotated region is the model's only source of evidence. Instead, it verifies that removing the annotated finding changes the model prediction, whereas matched background edits do not.
Therefore, the benchmark evaluates whether an attribution method can recover a human-annotated region that has been causally validated as necessary for the prediction. Additional evidence outside the box may still contribute, especially if it is not independently sufficient or does not change the final answer when edited. We will clarify that the annotation represents a causally validated reference region, rather than an exhaustive account of all evidence potentially used by the model.
(W2) Simplified Task Formulation: Evaluating models on binary VQA questions ("Is there evidence of X?") provides a controlled testbed but does not fully capture the complexities of real-world clinical tasks like nuanced radiology report generation or multi-step diagnostic reasoning.
We chose binary VQA because it provides a controlled setting in which the relationship between a selected region and the model prediction can be tested directly, enabling causal filtering and reliable attribution evaluation. We acknowledge in Appendix A.1 that richer tasks, such as radiology report generation, better reflect clinical practice. However, constructing causal attribution references for free-form outputs requires additional methodology because existing human annotations are not directly aligned with model-generated responses. Notably, even in this simplified setting, existing attribution methods often fail to recover the visual evidence causally used by the model.
(Q1) Does your approach assume 1:1 mapping of the disease/abnormal mapping of the bounding box? What if one diagnosis requires 3 out of 5 possible pathological changes?
We do not assume one-to-one mapping in either the MedGround-Bench benchmark or the MedFocus method. During the benchmark construction, we performed the image editing and causal filtering based on the original human annotation, which could potentially include multiple pathological changes if they are required for a diagnosis. Our editing and filtering pipeline will act on the union of all annotated regions rather than perturbing each annotated region individually. In the MedFocus method, we allow concept composites (unions of regions) to be scored jointly, and the method can test whether a combination of regions has a larger causal effect than the individual regions, thus capturing the joint effect of multiple pathological changes.
(Q2) What if the diagnosis uses overall structure like the shape of the lung?
If the model's diagnosis relies on the overall structure of both lungs, MedFocus can select a broad concept composite such as "left lung + right lung", since masking these regions removes not only local details but also the overall bilateral structure. To show that MedFocus actually recovers this structure, we measure how well each attribution method identifies bilateral (both-lung) structures on ImaGenome. A method is credited with identifying "both lungs" if its attribution covers both lung fields (overlapping at least 25% of each), evaluated against the ground-truth bilateral annotation. As shown below, MedFocus captures the bilateral structure far better than the pixel-saliency baselines, whose thresholded boxes rarely cover both lungs. (Recall = fraction of ground-truth bilateral cases whose attribution covers both lungs; Precision = fraction of predicted-bilateral cases that are truly bilateral.)
| Method | Recall | Precision | F1 |
|---|---|---|---|
| Attention Head | 5.7 | 82.1 | 10.7 |
| GradCAM | 57.6 | 69.6 | 63.1 |
| Occlusion | 37.0 | 77.4 | 50.1 |
| MedFocus | 87.8 | 74.0 | 80.3 |
Comments on the paper
1 comment
Dear Reviewers and Area Chair,
Thank you for your thorough and insightful reviews. We are encouraged by your positive feedback about the methodological novelty (Area Chair saN2, Reviewers qr8X, cSVb) and experimental breadth (Area Chair saN2, Reviewers qr8X, cSVb) on this clinically important problem (Area Chair saN2, Reviewer jfsJ). Following the comments and suggestions, we have revised our paper to address all concerns raised in the review process. Below, we summarize how our revisions address the main concerns mentioned in the meta review:
- Handling of multi-region cues: We clarified that our benchmark construction and method implementation are not restricted to one-region attribution. The original human annotation for foreground/background editing in the construction of MedGround-Bench may inherently include multiple pathological changes, and our method MedFocus supports the identification of region unions for model attribution. We presented further analysis to show that multi-region-based diagnosis is well-represented in MedGround-Bench, and that MedFocus provides better attribution than the baselines on multi-region cases such as bilateral lung regions. Moreover, we provided per-region analysis to show the consistent advantage of MedFocus across different anatomical regions.
- Evaluation fairness: We applied a single fixed threshold to convert all saliency maps to bounding boxes, ensuring a uniform evaluation protocol across baselines. Following the suggestion, we provided additional results with per-method tuned threshold values, showing that the baseline methods achieve higher IoU/F1 at the cost of lower precision, but remain inferior to MedFocus across metrics. To address the concern that saliency-map-based attribution methods may be disadvantaged on questions with coarse-grained annotations under the IoU metric, we highlighted the precision scores already reported in our paper and provided a detailed per-model breakdown, showing that MedFocus achieves the highest average precision across models.
- Intervention design: In addition to the zero-masking intervention used in MedFocus, we discussed the "healthy-tissue inpainting" alternative in our original paper. As suggested, we included an additional comparison to the "cross-disease replacement" intervention, which underperforms the adopted zero-masking strategy across metrics. This strengthens the justification of using zero-masking in our method. Moreover, we performed analysis to show that the advantage of zero-masking is driven by the targeted concept masking instead of generic image corruption.
- Evaluation scope and model coverage: We further clarified that our benchmark is anchored to human annotations and that binary VQA was chosen to enable clean causal filtering given the annotation resources available for CXR datasets. To account for differences in annotation granularity across datasets, we reported precision, recall, and F1 in addition to IoU. Based on the suggestion, we added another in-domain LVLM (Lingshu-7B), on which MedFocus achieves the best overall attribution performance, consistent with findings across the original six models.
We believe these revisions have strengthened our paper. We would be happy to provide further clarifications if there are any remaining concerns.
Thank you again for your time and consideration.
Sincerely,
Authors of Submission 15134
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Rebuttal
Thank you for the detailed and constructive review. Below we provide point-by-point responses to each of your concerns.
Thank you for the suggestion. We would like to first clarify that MedGround-Bench is constructed using RadEdit inpainting ("No [attribute]" / "No abnormality") to remove the target concept, rather than zero masking. For the MedFocus method, we use zero-masking and have compared it to healthy-tissue inpainting (RadEdit) in our Ablation Studies (Section 5.4), where zero-masking achieves better performance. Following your suggestion, we further add the cross-disease replacement intervention to this comparison. As shown below, MedFocus achieves the best IoU/F1 score with the zero-masking intervention, supporting the selection of zero-masking in our implementation.
To test whether the advantage of zero masking is driven by generic image corruption, we added a matched irrelevant-region control in which an equal-size region not containing the target concept is masked. As shown below, masking the target region produces a larger reduction in the answer probability than masking the control region. This result provides evidence that the response is primarily concept-specific rather than solely driven by the masking artifact.
During the benchmark construction, we do not impose a fixed diagnosis-to-anatomy mapping. Instead, the interventions are defined by the available human annotations rather than by a predefined anatomical lookup. For diagnoses requiring multiple regions, the intervention is applied to the union of the annotated regions. Such cases can therefore be retained when the combined edit changes the model's prediction, and the background edit does not. However, if the annotations omit relevant regions or fail to represent a global cue, the case may be excluded. This is a limitation of annotation coverage, which we will state explicitly.
To further quantify how often the diagnosis is based on multi-region evidence and whether they are effectively retained in the benchmark, we analyze the distribution of the region counts in the original ImaGenome data and the one in the retained questions in our benchmark. The results below show that multi-region cases are not underrepresented in the retained set. Cases with more than two annotated regions account for 27.8% of the source set but 44.7% of the retained set. One possible explanation is that single-region questions often require finer localized evidence, which may be more difficult for the evaluated models to identify and use reliably.
Following your suggestion, we conducted a validation-tuned thresholding experiment. Using 144 PadChest-GR training questions held out exclusively for hyperparameter selection, we tuned the quantile threshold separately for each baseline and model to maximize validation IoU. The results below show that the threshold tuning improves baselines. However, MedFocus continues to achieve the best performance, which does not require saliency-map thresholding.