potentialpaper

Extremely Sparse-View Computed Tomography from 2D Projections via Pose-Aware Diffusion Priors

Linrui Dai, Jinxiu Liang, Chu Zhou, Mae Yamaguchi, Ryuya Takahashi, Imari Sato

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. Extremely sparse-view computed tomography (xSV-CT) is critical when scanning time, motion, or radiation tolerance limits each scan to only a few projections. In many such scenarios, the same acquisition limits also constrain dataset construction, making pre-reconstructed 3D volumes from dense scans unavailable. This exposes a gap in current sparse-view approaches: Optimization-based methods, which use the sparse measurements directly but lack data-driven priors to suppress artifacts, and learning-based methods, which use strong priors but usually require densely scanned training volumes acquired outside the xSV-CT regime. We study this train-sparse / infer-sparse setting by learning a pose-aware diffusion prior from one 2D projection per training sample, then guiding diffusion sampling with measured-view fidelity, shared-volume reprojection, and projection-physics consistency for tomographic reconstruction. On two public CT datasets across 1-, 4-, and 8-view settings, the proposed method achieves the best novel-view synthesis scores and best or competitive reconstruction quality compared with baselines that use dense-volume supervision.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
3 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:44 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper addresses the challenge of Extremely Sparse-View Computed Tomography (xSV-CT) under a highly restrictive "train-sparse / infer-sparse" paradigm. The authors propose a framework consisting of: (1) A 2D denoising diffusion probabilistic model (DDPM) trained on only a single 2D projection per training sample, augmented with sinusoidal pose encoding and multi-scale cross-attention injection to learn angle-conditioned projection statistics; and (2) A testing-time guidance loop that directs reverse diffusion sampling using two complementary constraints: a geometric coherency loss and a physics-informed consistency loss. Evaluations on two public datasets (CT-RATE and SinoCT) show state-of-the-art performance in synthesizing novel views and reconstructing highly accurate 3D volumes under 1-, 4-, and 8-view contexts.

The manuscript received mixed reviews with major concerns around evaluation and the situation of the work in the body of existing methods. Specifically, the negative review points out a large body of published works on sparse view CT that the authors did not discuss or compare to in detail; however, without specifying any specific work that the authors miss discussing. The authors did address this concern in the discussion phase with additional discussion of the broader landscape of related methods. The review panel agreed to recommend this work for acceptance.

Final justification

See metareview.

Area Chair aDMb · Meta-reviewOpenReview ↗
Final justification
See metareview.
Read meta-review
Meta-review

This paper addresses the challenge of Extremely Sparse-View Computed Tomography (xSV-CT) under a highly restrictive "train-sparse / infer-sparse" paradigm. The authors propose a framework consisting of: (1) A 2D denoising diffusion probabilistic model (DDPM) trained on only a single 2D projection per training sample, augmented with sinusoidal pose encoding and multi-scale cross-attention injection to learn angle-conditioned projection statistics; and (2) A testing-time guidance loop that directs reverse diffusion sampling using two complementary constraints: a geometric coherency loss and a physics-informed consistency loss. Evaluations on two public datasets (CT-RATE and SinoCT) show state-of-the-art performance in synthesizing novel views and reconstructing highly accurate 3D volumes under 1-, 4-, and 8-view contexts.

The manuscript received mixed reviews with major concerns around evaluation and the situation of the work in the body of existing methods. Specifically, the negative review points out a large body of published works on sparse view CT that the authors did not discuss or compare to in detail; however, without specifying any specific work that the authors miss discussing. The authors did address this concern in the discussion phase with additional discussion of the broader landscape of related methods. The review panel agreed to recommend this work for acceptance.

1 comment
Authors · CommentOpenReview ↗

Response to Area Chair aDMb

We sincerely thank the Area Chair for the clear and constructive summary of the reviews and for identifying the key issues that should be addressed during the discussion period. We carefully prepared our rebuttal to directly address each of these concerns.

Regarding the empirical validation, we have added a per-baseline implementation description and an explanation of C²RV's behavior at M≤8, an off-model physics stress test, a sharper definition of the train-sparse setting (for KBVa), and a inference-time analysis (for NpsB). All methods are evaluated on two datasets, one with a simple Radon model and the other with a realistic scanner-physics simulator, to probe performance under both ideal and more realistic scenarios. (for NpsB, updated after discussion with Reviewer KBVa).

Regarding the positioning with respect to prior work, following the Area Chair’s suggestion, we expanded the discussion of the relevant sparse-view CT and X-ray-to-CT generation literature we believe NpsB has in mind, and credited it explicitly; each still forms its training pairs from reconstructed volumes, the requirement our train-sparse setting removes. If the reviewer names any specific work or baseline they consider missing, we will discuss or run it within the discussion period.

The remaining concerns, including technical clarity and the underlying assumptions, are addressed point by point in our rebuttal. We would be grateful for any additional feedback from the Area Chair or the reviewers and are happy to provide further clarifications or experiments if they would be helpful during the discussion period.

Reviewer NpsBOpenReview ↗
Rating
3/6
Confidence
4/5
Quality
2/4
Clarity
2/4
Significance
2/4
Originality
1/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper addresses the challenge of Extremely Sparse-View Computed Tomography (xSV-CT) under a highly restrictive "train-sparse / infer-sparse" paradigm. In specific clinical and industrial environments (e.g., intra-operative C-arm navigation, dynamic cardiac imaging, or scanning highly radiation-sensitive biological specimens), fully-sampled 3D CT scans are unavailable for both training data curation and inference testing. The authors propose a framework consisting of: (1) A 2D denoising diffusion probabilistic model (DDPM) trained on only a single 2D projection per training sample, augmented with sinusoidal pose encoding and multi-scale cross-attention injection to learn angle-conditioned projection statistics; and (2) A testing-time guidance loop that directs reverse diffusion sampling using two complementary constraints: a geometric coherency loss and a physics-informed consistency loss. Evaluations on two public datasets (CT-RATE and SinoCT) show state-of-the-art performance in synthesizing novel views and reconstructing highly accurate 3D volumes under 1-, 4-, and 8-view contexts. There are many published works on the topic (the authors, unfortunately, simply ignored many of previous publications on the topic), the work does not add much either theoretically or practically.

Strengths and weaknesses

Integrating projection physics (Radon transform) into the diffusion sampling step merges statistical learning with established physical principles. The choice of using an adaptive Adam optimizer for step-wise corrector updates may add numerical stability. Unlike pure learning-based regression networks that can hallucinate non-existent anatomies, the inclusion of physics constraints may allow this framework to preserve global structural integrity and degrade into mild blurring during out-of-distribution (OOD) testing.

The reconstruction pipeline requires optimization loops through differentiable projection/reprojection operators at every denoising timestep. The inference time is too long, severely restricting its viability for real-time intraoperative applications. The novelty of the study is at most moderate, as there have been numerous studies on view generation and on extremely sparse CT reconstruction. The authors frame their "train-sparse / infer-sparse" paradigm and projection-domain diffusion approach as almost entirely unprecedented, omitting several crucial foundational and concurrent developments.

The work's core premise relies on synthesizing high-fidelity volumes from extremely limited 2D projections. However, the authors fail to credit the pioneering work by others, which originally established the paradigm of deep learning-based CT reconstruction from a single or a few projection views.

Questions

The finite-order Range-Condition surrogate seems to be inherently restricted to parallel-beam or rebinned fan-beam configurations. While rebinning works well mathematically for standard geometries, it adds algorithmic complexity and does not natively support true cone-beam setups or non-coplanar geometries without translating to alternative metrics.

Although the problem formulation intends to skip dense 3D volume supervision, the clinical datasets utilized to evaluate the methodology were still curated via simulated projections extracted from public dense scans to capture metric references. Prospective evaluation on true experimental, natively sparse-only data remains unaddressed.

Limitations

yes

Final justification

The responses regarding the train-sparse scope distinction, geometry coverage, and efficiency context addressed my main concerns. I am increasing my score to 3.

Formatting concerns

non concerns

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for recognizing that integrating Radon physics into the sampling step combines statistical learning with established physical principles, and that the physics constraints help preserve global structure rather than hallucinate anatomy. We address the concerns below, and would welcome any specific reference the reviewer would like us to add.

W1: Inference time cost:

We agree that inference time is an important practical consideration. At our default setting (N=180), reconstruction from 4 sparse views takes approximately 46 minutes on CT-RATE, while increasing the number of input views has little effect (47 min for 8 views and 50 min for 32 views). Among methods needing only per-dataset retraining this is an order of magnitude faster than the closest comparisons (e.g., DiffusionMBIR exceeds 10h per case on NVIDIA RTX A6000 GPUs as our setting, and TPDM (ICCV'23) reports exceeding20h at 256³ in their paper with NVIDIA RTX 3090 GPUs).

Importantly, the current implementation is readily parallelizable. We currently synthesize 48 projections at a time on a single GPU, and distributing this computation across multiple GPUs can further reduce the wall-clock time without changing the algorithm or reconstruction quality. Experimenting with four GPUs that parallelize the synthesis of full N=180 projections can bring runtime to roughly 35% at unchanged performance.

In addition, the runtime can be adjusted by choosing the number of synthesized projections N. As discussed in the manuscript (L519), the runtime increases approximately linearly with N (t≈10+0.2N min). Figure 5 reports the corresponding quality-runtime trade-off across different values of N, allowing users to balance reconstruction quality against computational cost.

Finally, real-time intra-operative imaging is one motivating application, but latency reduction is not the primary target of this work. Our focus is on acquisition-limited scenarios, including low-dose CT, industrial inspection, and retrospective dynamic CT, where a limited number of available projections is often the key challenge rather than reconstruction latency. To better clarify the intended scope and practical trade-offs, we will move the runtime discussion from the appendix to the main paper and clarify these implementation details in the revised manuscript.

W2: Credit to prior work

We do not claim that novel-view generation or xSV-CT are themselves new; both are cited extensively in the Related Works. Our claim is narrower: to the best of our knowledge, this is the first work among existing publications to explicitly study a train-sparse / infer-sparse setting for sparse-view CT, in which no reconstructed slice or volume is used as supervision at any stage and is beneficial to scenes where a dataset of dense-view volumetric reconstructions is difficult to obtain beforehand.

Following the Area Chair’s suggestion, we will expand the discussion of prior sparse-view CT literature in the revised manuscript to better position our work with respect to existing methods. As the review does not identify specific missing prior works or concrete baselines, we will provide discussion of the line we believe is intended, which we refer to as X-ray to CT generation from one or a few views at predefined poses: e.g., “Patient-specific reconstruction…” (Nature BME’19), X2CT-GAN (CVPR’19), MedM2G (CVPR’24). We will credit these explicitly as establishing the fact that networks can infer volumetric structure from very few views. However, every one of them still forms its training pairs from reconstructed 3D slices or volumes, which our setting removes, and scaling them to incorporate different scanner poses or more views is not trivial. The same training requirement holds for other prior volume-based methods we discussed, such as DIF-Gaussian (MICCAI’24), TPDM, X-LRM (3DV’26), and the volume-based baselines we compare against. We will add these references in revision, and would be willing to discuss any other specific work the reviewer has in mind, or run any baseline they consider necessary.

Q1: Geometry coverage

The finite-order Range-Condition surrogate is indeed used only for the physics-informed consistency loss, as stated in the Limitations (L292–294), and does not restrict the framework itself. The geometric coherency loss is geometry-agnostic and applies unchanged to cone-beam and non-coplanar geometries.

Moreover, the rebinning approximation can be removed by replacing the finite-order Range-Condition surrogate with Grangeat’s condition for cone-beam geometry. In this case, full 3D reconstruction additionally requires synthesized projections to satisfy Tuy’s sufficiency condition through non-planar acquisition orbits. We will clarify this discussion and present it as a promising future direction.

Q2: Measured versus simulated data in our evaluation

This concern applies only partially to our evaluation. Among the two datasets used in the paper, only CT-RATE uses simulated projections. For SinoCT, we use the real fan-beam measurements provided by the dataset, without any forward projection during training. Therefore, the SinoCT experiments are already performed entirely in the measurement domain.

We agree that prospective validation on radiation-sensitive specimens without dense reference volumes is an important future direction. As stated in L292, we plan to evaluate our framework on such truly sparse-only data in future work.

Authors · CommentOpenReview ↗

Brief summary of our previous rebuttal

Dear Reviewer NpsB,

Thank you again for the time you spent on our submission. We provide a pointer to where your main concerns are addressed here (updated after discussion with Reviewer KBVa); please see our earlier response for other details:

  • On inference time: although reducing reconstruction latency is not our primary target, compared with more recent baselines DiffusionBlend, DDS for sparse-view reconstruction as pointed by Reviewer KBVa, our model retains comparable inference latency, rather than being superior. We will clearly describe our method as removing the requirement for densely scanned training data while having comparable runtime as the latest baselines.
  • On positioning: we will add the single-/few-view X-ray-to-CT generation line, including "Patient-specific reconstruction…" (Nature BME'19), X2CT-GAN, and MedM2G, crediting them as establishing that networks can infer volumetric structure from very few views. We will also make clear how our setting differs: like the volume-based methods we already discuss, these approaches still form their training pairs from reconstructed slices or volumes, and are non-trivial to retrain or apply at a different view count than they were designed for. We would also include the work Lai et al. (ISBI'24) from Reviewer KBVa, which also assumes dense-view supervision, but learns solely on projections. If other work belongs in this discussion, we would welcome the pointers, now or for the revision.
  • We also thank Reviewer KBVa for pointing out that our previous description of SinoCT was insufficiently precise. We will clarify the original question Q2 in the following: To quantitatively evaluate the performance of different methods under a more realistic setting, we included SinoCT with CatSim-simulated projections. Currently, our work serves to validate that projection-domain priors can be used for tomographic reconstruction under sparse view inputs. We will scope the motivation accordingly, and are collecting specimen data for a qualitative prospective study in future work.

We remain available for any further clarification while the author discussion window is open.

Reviewer JyFaOpenReview ↗
Rating
6/6
Confidence
5/5
Quality
4/4
Clarity
4/4
Significance
4/4
Originality
4/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

In this paper, the authors propose an approach to reconstruct a full CT from extremely sparse-view CT (xSV-CT), such as 1-, 4-, and 8-views. Their framework consists of two novelties. First, a 2D pose-aware prior is trained to generate a 2D view conditioned on the positional embedding. That positional embedding is the camera angle, rather than a spatial position, modeling CT acquisition physics. Second, during inference, all camera rotations (positional embeddings) are used to generate a full volume, but the true acquired views are inserted appropriately through each timestep. Corrections are done through the denoising with both a geometric and physics-informed loss to guide the diffusion towards feasible solutions. This is a very sensible and principled way of doing posterior sampling leveraging CT physics. The authors perform several experiments to validate their approach, and notably compare to several existing methods in xSV-CT. Importantly, the authors show the drawbacks of their results and carefully discuss limitations and future work.

Strengths and weaknesses

I think this is a very well-written and scientifically sound paper. I have only one brief comment. The proposed approach is conceptually very close to the Diffusion Posterior Sampling (DPS) family of approaches, as well as the Denoising Diffusion Null-space Model (DDNM) family of approaches. Steerable conditional diffusion is somewhat in the same family as DPS, for instance, but requires retraining, whereas the authors of this paper do not require retraining (similar to DPS). I think a brief comment on the connection between methods is merited. Otherwise, great work.

Questions

My question here is a repeat of my comment above: how is this work related to DPS and DDNM methods?

Limitations

yes

Final justification

This paper is still strong after rebuttals. My only real concern was the connection to existing literature, which the authors have addressed. I have no real reason to keep my score below the highest, so I'm updating it to 6: Strong Accept. This is a paper that deserves to be shown at NeurIPS because it is a meaningful contribution to the field, and it would be a shame not to include it.

Formatting concerns

n/a

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the thoughtful observation and for highlighting the connection to the DPS/DDNM family of methods. We agree that explicitly discussing this relationship will strengthen the paper. Below, we provide a detailed comparison, clarifying both the conceptual similarities and the important differences between our approach and these methods.

W&Q: Relation with DPS and DDNM methods.

Relation to DPS: Our guided update (Eq. 13-14) is in the DPS family: we differentiate a consistency objective through the Tweedie estimate and take a gradient step on current denoising result, and the same network serves every input measurement configuration (different from Steerable Conditional Diffusion which requires retraining).

Relation to DDNM: Our interpretation of the loss function Lgeo\mathcal{L}_{geo} by decomposing intermediate volumes y^0∣t\hat{y}_{0|t} onto range-consistent y^0∣tC\hat{y}^C_{0|t} and residual y^0∣tR\hat{y}^R_{0|t} counterparts is similar to the range-null space decomposition in DDNM, but we do not use a direct projection onto the range space here since the Radon inverse A†\mathcal{A}^\dagger can introduce significant artifacts under sparse sampling.

What is different relative to them: Original DPS and DDNM both assume a pre-trained prior over the target domain (reconstruction) already exists (in our case this would be a pre-trained prior over reconstructed volumes). Our contribution here is to shift the pre-trained prior from the target reconstruction domain by learning from single, pose-conditioned 2D projections with no volumetric data at any stage. Together with guidance objectives specific to tomography rather than generic data fidelity, we enable xSV-CT for more general data domains. So neither the prior nor the DPS-style update alone accounts for the result.

We appreciate the reviewer’s suggestion and will include a discussion comparing our approach with DPS, Steerable Conditional Diffusion, DDNM, and other closely related methods in the revised manuscript.

Authors · CommentOpenReview ↗

Brief summary of our previous rebuttal

Dear Reviewer JyFa,

Thank you again for your careful reading. Here is a brief note on how your comment will shape the revision, we are also open to any further question you may have in mind during the author discussion phase.

Following your suggestion, we have posted a response discussing the connection between our sampling guidance and the DPS and DDNM families, covering both the similarities (a DPS-style gradient update through the Tweedie estimate, and a DDNM-like range/null-space view of the consistency loss) and a key difference: our prior is learned from single, pose-conditioned 2D projections with no target-domain (reconstruction) data guidance at any stage, combined with guidance objectives specific to tomography rather than generic data fidelity.

Reviewer KBVaOpenReview ↗
Rating
4/6
Confidence
5/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper studies extremely sparse-view CT reconstruction under a train-sparse / infer-sparse setting. The proposed method trains a pose-aware projection-domain diffusion model and then uses consistency-aware guided generation to synthesize dense novel projections. The generated projections are constrained by measured-view fidelity, shared-volume reprojection consistency, and a finite-order projection-physics consistency surrogate based on Helgason–Ludwig range conditions. The final volume is reconstructed from the measured and generated projections.

My overall assessment is mildly positive. While projection-domain diffusion has been explored in the community, it has generally struggled to achieve strong reconstruction performance. In this context, the present work may offer useful insights, both in its methodological design and in its focus on the extremely sparse-view CT setting. The method is technically plausible. The empirical results are strong for novel-view synthesis and competitive for volume reconstruction. However, several important points need clarification before I can fully assess the strength of the claims, especially the precise meaning of the train-sparse setting, the fairness and reproducibility of the baselines, and the gap between projection-level improvements and final reconstruction quality.

Strengths and weaknesses

Strengths:

  1. Reasonable method design. Modeling a pose-conditioned projection distribution is a plausible way to exploit large collections of sparse 2D measurements. The sinusoidal pose encoding and multi-scale pose injection are well motivated by the periodicity and complementary-view structure of CT projections.
  2. Tomographic consistency is explicitly considered. A major weakness of projection-domain generation is inconsistency across independently generated views, which can lead to severe error accumulation during back-projection reconstruction. The proposed shared-volume reprojection loss and range-condition-based consistency loss are reasonable attempts to mitigate this issue.
  3. Useful robustness and failure analyses. The analyses on noisy inputs, angular perturbation, cross-seed repeatability, and out-of-distribution targets are valuable and make the paper stronger.

Weaknesses

  1. The train-sparse / infer-sparse setting needs a sharper definition.

    • The paper motivates a setting where full volumes are unavailable for training, using examples such as fragile, dynamic, or dose-sensitive targets. I think this setting deserves more discussion. What concrete real-world scenarios truly prevent the acquisition of full-sampled volumes for training? For example, in the cited fragile, dynamic, or dose-sensitive cases, is it impossible to obtain at least some fully sampled volumes from related subjects, phantoms, retrospective scans, or less constrained acquisition protocols?

    • The construction of the training data also needs more clarification. For CT-RATE, the paper states that projections are simulated from CT volumes. Were projections simulated densely over many angles, or only at the sparse angles used during training and inference, such as 0°, 45°, 90°, and 135°? If the training dataset actually contains dense-view projections, then the setting may not be truly train-sparse in a data-curation sense. Even without explicitly using full volumes, dense-view projections can in principle be reconstructed into full volumes, making them conceptually close to dense-volume supervision. The paper should clearly distinguish between sparse access during model training and sparse acquisition during dataset construction.

  2. More Baselines Implementation Details & Results Explanation Required

    • The comparison includes strong and diverse baselines, including DiffusionMBIR, C²RV, and DSDF. However, the paper does not provide enough information to judge whether these methods were adapted fairly to the present datasets, geometries, resolutions, and view counts. For example, it is unclear how the diffusion prior in DiffusionMBIR was trained, and whether C²RV and DSDF were retrained for each dataset and each view setting.

    • This concern is particularly relevant because the qualitative results of C²RV appear surprisingly weak and blurry, and do not seem to match the level of qualitative performance shown in the original C²RV paper. I recommend that the authors provide more implementation details for each baseline, including the training data, supervision type, geometry, view configuration, retraining protocol, and whether official code or checkpoints were used.

  3. The projection-level gains do not fully translate into volume-level gains.

    • The novel-view synthesis results are substantially stronger than the reconstruction results. This is important because errors in generated projections can accumulate when these projections are fed into FBP/FDK or other reconstruction algorithms. I think this may be one reason why projection-domain diffusion models have historically struggled to achieve strong CT reconstruction performance. For example, DiffNR [1] also compared projection-domain diffusion priors, but found them to perform much worse than CT slice image-domain priors. I would like the authors to discuss how their method relates to this issue.

    • More broadly, I think this point deserves deeper discussion. My understanding is that one motivation for projection-domain diffusion comes from natural-image 3D vision, where many works use pretrained image diffusion models to constrain novel-view synthesis, such as DreamFusion-style methods. However, there is an important gap between natural-image 3D vision and CT reconstruction. In natural-image 3D vision, novel-view synthesis is often itself a valuable task, since the final goal may be to render new views. In CT, however, the main goal is usually a reliable slice or volume reconstruction. It is therefore worth discussing when synthesized X-ray projections are actually useful, and when it would be preferable to directly reconstruct high-quality CT slices or volumes.

  4. Off-model physics should be discussed and tested.

    • The robustness analysis covers low-dose noise and angular perturbations, but not structured violations of the assumed projection model, such as metal artifacts, beam hardening, scatter, or truncation. This is particularly relevant because metal traces can create strong structured sinogram patterns. In such cases, the geometric and range-condition losses might propagate corrupted measurements into generated views, or incorrectly suppress real but off-model signals.

    • I suggest that the authors include a small experiment on CT data with metal implants or simulated metal artifacts. Even a limited stress test would help clarify whether the proposed projection-domain guidance remains reliable when the Radon-model assumptions are violated.

[1] Su, Y., et al. (2026). DiffNR: Diffusion-based Neural Reconstruction for Sparse-view CT. AAAI 2026.

Questions
  1. Can the authors provide an angle-conditioned uncertainty estimate or trust map for generated structures far from the measured angles? Such information could allow the reconstruction algorithm to use generated projections more selectively or with angle-dependent weights, potentially improving the reliability of the final volume reconstruction.
Limitations

yes

Formatting concerns

N/A

5 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the constructive and thoughtful review. We are pleased that the pose-conditioned design, the explicit treatment of tomographic consistency, and the robustness analyses were found to be well motivated. We have carefully addressed all of the reviewer’s comments below, including the requested additional experiment.

W1: The train-sparse setting.

Clarification of the motivation: In the paper (L27), we motivate the train-sparse setting using non-repeatable scenes, such as evolving batteries, beating hearts, and delicate biological or archaeological specimens that may be damaged by prolonged X-ray exposure. Although a few densely sampled volumes may be obtainable in such cases, obtaining a sufficient number of densely sampled scans for training is often infeasible. Our method therefore learns directly from sparse-view acquisitions without requiring densely sampled training data.

Sparse access at training: In our default train-sparse setting, each training sample consists of a single (projection, pose) pair. For CT-RATE, we generate only one projection at a randomly sampled pose for each CT volume; for SinoCT, we use one measured projection per sample. Training samples are never grouped by object identity, so the model never observes two views of the same object. As a result, the training set contains 4200 independent projection-pose pairs rather than 4200 dense sinograms. Tab.6 further shows that our method generalizes to settings with 1, 4, or 32 projections per object, and even 32 projections remain far below the hundreds of views (typically >400 for a 256³ volumes based on the Nyquist sampling theorem) required for accurate CT reconstruction.

W2: Baseline implementation and retraining protocol.

All three baselines use official code and requirements, retrained by us. No checkpoints were transferred across datasets or view counts. We used identical splits and preprocessing described in Appendix B, with sample geometry and resolution matched to ours. All methods are trained until the loss was flat for 10 epochs. We summarize their training paradigms below:

Baseline Supervision Retraining
DiffusionMBIR Reconstructed axial slices Per-dataset (view-count agnostic, as ours)
C²RV Reconstructed 3D volumes Per-dataset and per-view-count
DSDF Reconstructed 3D volumes Per-dataset and per-view-count, both stages

On C²RV. The evidence that our implementation is faithful is that it behaves correctly as the view count grows in Fig.7 and eventually reaches non-blurry reconstruction, we can also observe that C²RV’s reconstructions converges as more projections are provided at inference by comparing 1/4/8-view reconstructions in Appendix E. For its blurriness, we speculate that since C²RV relies on aggregating multi-scale cross-view features, at the displayed setting in Fig.1 (4-view) as well as Appendix E there may be too few views for that aggregation to constrain the volume.

W3: projection-level/reconstruction-level gains.

On DiffNR: DiffNR claims from theoretical reasoning that projection-domain prior can accumulate error. This claim is correct on DiffNR’s reasoning background such as unconstrained projection synthesis (also confirmed by removing both inference-time constraints in Tab.3) or feed-forward projection correction (like its SliceFixer) without inter-projection consistency constraints. Our performance gain here thus does not contradict their observation: Our method uses a guided inference process that explicitly enforces mutual, cross-projection consistency during sampling. By constraining generated views to be geometrically and physically consistent with one another, we effectively prevent the independent error accumulation among projections.

On reconstruction performance. Our claim is not that projection-domain priors universally outperform slice-domain priors. Rather, as shown in Tabs. 1–2 and Fig. 7, our method matches or exceeds methods trained with dense-volume supervision while requiring no volumetric training data, with the largest gains in the extremely sparse-view regime that we target. When dense volumes are available and MM is not extremely small, a slice/volume-domain prior is simpler and we would recommend it. Our approach is preferable when dense volumes cannot be curated at scale, or when one wants to avoid inheriting reconstruction artifacts into the prior. We will clarify this point explicitly in the revision and cross-reference Fig.7.

W4: Behavior under off-model physics.

We thank the reviewer for raising this point. To stress-test our method under structured violations of the Radon model, we simulate beam hardening from metal implants following “Convolutional Neural Network Based Metal Artifact Reduction” (TMI'18). Following its policy, we synthesize several ellipsoidal metal implants (averaging around 4000 voxels each) into the sparse measurements for 10 cases on the CT-RATE dataset, and compare reconstruction quality with and without metal present. PSNR is computed against the clean (metal-free) volume:

Variant PSNR vs. clean volume
FBP, M=360, corrupted projections 20.7 dB
FBP, M=360, corrupted projections, non-metal region mask 21.2 dB (not ∞ due to the beam hardening artifacts on tissues surrounding the metal)
Ours, M=8, corrupted projections 26.4 dB (-2.2 dB compared to reconstructing on clean projections for these 10 cases)
Ours, M=8, corrupted projections, non-metal region mask 27.7 dB (-0.9 dB compared to reconstructing on clean projections for these 10 cases)

As expected, variants 1 and 3 deviate from the clean volume because synthetic metal ellipsoids are now present in the measurements, and FBP propagates the resulting beam-hardening streaks throughout the reconstruction. In contrast, our method, despite using only 8 views, achieves higher PSNR than FBP applied to the same corrupted projections, indicating that our reconstructions retain fewer beam-hardening artifacts.

This is most evident when comparing variants 2 and 4. Outside the synthetic metal region, FBP remains degraded by beam-hardening streaks (21.2 dB), whereas our method achieves 27.7 dB, only 0.9 dB below reconstruction from clean projections. This indicates substantially greater robustness to off-model corruption. We attribute this robustness to our diffusion prior: having been trained only on projections that obey the Beer-Lambert law, it seeks to explain the anomalous metal traces at inference time in a physically well-posed manner, rather than reproducing artifacts like FBP.

Additionally, we observe that the implants themselves remain correctly localized, so the improvement outside the metal reflects suppression of the streak artifacts rather than of the implant. This is consistent with the OOD behavior in our existing analysis: trained only on projections obeying the Beer-Lambert law, the prior explains anomalous traces in a physically well-posed way and degrades toward mild blurring rather than reproducing artifacts.

In summary, our method shows a degree of robustness to metal-induced beam hardening. In contrast, severe sinogram truncation remains a limitation because both training and inference assume complete measurements, a limitation shared by most sparse-view CT methods. The effect of X-ray scatter is beyond the scope of this work without an accurate physical forward model. We will add a discussion of these off-model regimes and their differing effects in the revision.

Q1: Angle-conditioned trust map.

We agree that an angle-conditioned trust map would be valuable. Please refer to Tab.4 for related analysis: cross-seed ℓ2\ell_2​ residuals decrease as measurement density increases, while Fig.8 shows that the residual grows with angular distance from the nearest measured view. Based on this observation, a trust map can be estimated without ground truth or retraining by running guided inference with multiple random seeds and computing the prediction variance for each pixel (or projection). Higher variance indicates projections that rely more heavily on the learned prior than on measurements. As suggested by the reviewer, this uncertainty can be directly incorporated as an angle-dependent confidence weight during reconstruction, down-weighting synthesized views farther from measured angles (e.g., with weaker losses). We will include a trust-map visualization and a preliminary confidence-weighted reconstruction in the revised manuscript.

Authors · CommentOpenReview ↗

Brief summary of our previous rebuttal

Dear Reviewer KBVa,

Thank you again for your careful reading. We provide a brief pointer to where each of your main concerns is addressed here as a summary; please see our earlier response for the full details:

  • On the train-sparse setting: each training sample is a single (projection, pose) pair, and samples are never grouped by object identity, so the model never observes two views of the same object.
  • On baselines and implementation: we used the official code for each method, retraining per-dataset and per-view-count where needed. For C²RV, the indication that our implementation is faithful is that its quality rises steadily with view count and reaches non-blurry reconstructions (Fig. 7, Appendix E); the blur is a property of the M ≤ 8 regime.
  • On projection- vs. volume-domain gains: we explain why our result does not contradict DiffNR's observation, and why projection-based modeling is preferable when a large dense-view dataset cannot easily be curated and/or a high level of sparsity is required.
  • On off-model physics: as requested, we introduce synthetic beam-hardening artifacts into the input measurements and find that our method remains meaningfully robust, accurately locating the metal presence while suppressing the streak artifacts around the synthetic metal.

We are also happy to address any further questions you might have during the author discussion phase.

Reviewer KBVa · CommentOpenReview ↗

Thank you for the detailed response. The rebuttal has addressed some of my questions, particularly W3 (projection-domain versus slice-domain priors), W4, and Q1. I appreciate the authors’ willingness to incorporate these discussions into the final version. In particular, I believe that a more thorough discussion of W3 would help the community better understand when each of these two paradigms should be preferred.

However, I still have several concerns regarding the remaining issues.

W1: Motivation, validation of the proposed setting, and novelty

The authors provide clearer examples of the scenarios for which the proposed train-sparse / infer-sparse setting may be relevant, including evolving batteries, beating hearts, and delicate biological or archaeological specimens that may be damaged by prolonged X-ray exposure. However, it is unfortunate that the method is not actually evaluated on data from any of these scenarios.

I understand that acquiring such data may be difficult. Nevertheless, these applications constitute the central motivation for the proposed setting, and they may present challenges that differ substantially from those found in conventional medical CT data, such as temporal changes, non-standard materials, severe distribution shifts, or different imaging physics. Consequently, evaluation only on standard medical CT datasets leaves a gap between the motivating applications and the current experimental validation.

I would also like to correct one point concerning SinoCT. According to the official dataset description, the SinoCT sinograms were simulated using GE’s CatSim software. Although CatSim is a validated, high-fidelity simulator for GE scanners, these sinograms should not be described as physically acquired projection data. They are more realistic than projections generated using a simplified Radon transform, but they remain simulated rather than directly measured.

The authors also emphasize that this is “the first work among existing publications to explicitly study” the train-sparse / infer-sparse setting. However, Lai et al. [1] appear to have explored a conceptually related setting. Their method, which is similar in spirit to pixelNeRF, reconstructs knee CT volumes from sparse biplanar X-rays using a self-supervised neural field without relying on high-quality CT volumes as supervision. Their training projections are not as sparse as the one-view-per-sample setting considered here, so the two settings are not identical. Nevertheless, this prior work seems sufficiently related that the novelty claim should be qualified and the distinction discussed explicitly.

W2: Reproduction of C²RV

I remain unconvinced that the reported C²RV results constitute a reasonable reproduction. The authors’ explanation that “it behaves correctly as the view count grows” is insufficient. It is expected that reconstruction quality improves as more views are provided; this trend alone does not validate the absolute quality of the reproduction.

In particular, the C²RV results in Figs. 20 and 23 remain highly blurred even with eight input views. By contrast, Fig. 5 of the original C²RV paper presents substantially sharper reconstructions using only six views. This discrepancy is difficult to explain because both studies primarily operate on volumes of approximately (2563256^3) resolution, and the CT-RATE training set used in this submission appears to contain more training cases.

The authors should therefore provide a more convincing explanation for this gap, together with sufficient implementation details to establish that C²RV was trained and evaluated appropriately. Simply showing that its performance improves monotonically with the number of views does not resolve the concern that this baseline may be significantly underperforming relative to its original implementation.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…