MedExAgent: Training LLM Agents to Ask, Examine, and Diagnose in Noisy Clinical Environments
Yicheng Gao, Xiaolin Zhou, Yahan Li, Yue Zhao, Ruishan Liu
NeurIPS 2026
TL;DR. We model interactive diagnosis as a POMDP over questioning, exam ordering, and diagnosis with noisy observations and exam costs, then train an 8B MedExAgent via SFT+DAPO to match 70B baselines on OOD diagnostic accuracy.
Abstract. Real-world clinical diagnosis is a complex process in which the doctor is required to obtain information from both interaction with the patient and conducting medical exams. Additionally, the doctor needs to adapt to different patient personas, as well as noisy and incomplete information that can happen at any time during the process. However, existing benchmarks for medical LLMs and methods for automatic diagnosis largely simplify this process by reducing it to single-turn question answering, noise-free conversations, or sequential exam making, etc., ignoring the interactive and uncertain nature of clinical diagnosis. In this paper, we aim to address this gap by formalizing clinical diagnosis as a Partially Observable Markov Decision Process (POMDP) with three action types: questioning the patient, ordering medical exams as tool calls, and issuing a diagnosis. We also introduce a systematic noise model comprising seven patient noise types and three exam noise types. Using our proposed environment, we train an effective diagnosis agent, \textbf{MedExAgent}, through a two-stage pipeline that first performs supervised finetuning on synthetic conversations structured after the Calgary-Cambridge model for clinical interviews, and then applies DAPO to optimize a composite reward capturing diagnostic accuracy, tool call quality, and exam cost including financial cost and patient discomfort. Through extensive experiments and ablation studies, we demonstrate that MedExAgent achieves diagnostic performance comparable to larger models while maintaining cost-efficient examination strategies.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:48 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper proposes MedExAgent, an 8B medical language model agent for interactive clinical diagnosis. Rather than treating diagnosis as a single-turn QA task, the paper formulates diagnosis as a POMDP in which the agent iteratively asks questions, orders exams, and produces a final diagnosis. The model is trained using supervised fine-tuning on synthetic doctor-patient conversations followed by RL with a reward that jointly considers diagnostic accuracy, appropriate tool use, and examination cost. The authors conducted multiple medical diagnosis benchmarks, demonstrating competitive performance with larger models while encouraging more cost-aware clinical decision-making.
Strengths:
-
The paper addresses an important and practically relevant problem by modeling diagnosis as an interactive decision-making process rather than a single-turn prediction task.
-
The overall framework is technically well motivated, combining supervised fine-tuning and reinforcement learning with a POMDP formulation that explicitly models questioning, exam ordering, and diagnosis.
-
The experiments are comprehensive, including comparisons with strong baselines, ablation studies, and discussions.
Weaknesses:
-
The paper is motivated by robustness to noisy clinical interactions, yet the primary evaluation is conducted on clean benchmark datasets. Although noise is introduced during training, the evaluation provides limited evidence that the proposed MedExAgent is actually more robust under noisy patient responses or examination uncertainty, and no systematic robustness analysis across different noise levels is presented.
-
Another concern is that both training and evaluation depend on LLM-based simulation. The doctor-patient conversations, patient simulator, and reward computation all rely heavily on synthetic interactions, yet the realism of these simulations is not validated against real clinical practice or human experts. Thus, it remains unclear whether the reported improvements would transfer beyond the simulated environment.
-
The same LLM family is used for reward computation and final evaluation, raising concerns that the learned policy may be optimized toward the preferences of the judge model rather than toward improved clinical reasoning. While the paper includes limited validation of the judge, the current evidence is insufficient to eliminate this concern.
-
Additional concerns include the reliance on ground-truth diagnoses during synthetic data generation, the lack of detailed error analysis, insufficient validation of the proposed patient personas and examination noise models, and the absence of human or clinician evaluation to verify the realism of the generated interactions.
To sum up, while I find the problem important and the proposed direction promising, I am not convinced that the current experimental evidence sufficiently supports the paper's central claims of robust interactive diagnosis in realistic, noisy clinical settings. Therefore, the paper is not ready for publication before rebuttal.
The rebuttal would be most helpful if it can clarify any misunderstandings regarding the evaluation protocol, the role of the LLM judge, and the construction of the synthetic training environment. However, if the reviewers' understanding is correct, the principal concerns relate to the realism and validity of the evaluation methodology itself. In particular, stronger evidence demonstrating robustness under noisy conditions, validation of the simulated clinical environment, and independent evaluation (e.g., clinician assessment or alternative judges) would substantially strengthen the work, but these issues are unlikely to be fully addressed during the rebuttal period.
Final justification
The authors addressed most of the reviewers’ concerns during the rebuttal, which convinced me to recommend acceptance.
Read meta-review
Meta-review
This paper proposes MedExAgent, an 8B medical language model agent for interactive clinical diagnosis. Rather than treating diagnosis as a single-turn QA task, the paper formulates diagnosis as a POMDP in which the agent iteratively asks questions, orders exams, and produces a final diagnosis. The model is trained using supervised fine-tuning on synthetic doctor-patient conversations followed by RL with a reward that jointly considers diagnostic accuracy, appropriate tool use, and examination cost. The authors conducted multiple medical diagnosis benchmarks, demonstrating competitive performance with larger models while encouraging more cost-aware clinical decision-making.
Strengths:
-
The paper addresses an important and practically relevant problem by modeling diagnosis as an interactive decision-making process rather than a single-turn prediction task.
-
The overall framework is technically well motivated, combining supervised fine-tuning and reinforcement learning with a POMDP formulation that explicitly models questioning, exam ordering, and diagnosis.
-
The experiments are comprehensive, including comparisons with strong baselines, ablation studies, and discussions.
Weaknesses:
-
The paper is motivated by robustness to noisy clinical interactions, yet the primary evaluation is conducted on clean benchmark datasets. Although noise is introduced during training, the evaluation provides limited evidence that the proposed MedExAgent is actually more robust under noisy patient responses or examination uncertainty, and no systematic robustness analysis across different noise levels is presented.
-
Another concern is that both training and evaluation depend on LLM-based simulation. The doctor-patient conversations, patient simulator, and reward computation all rely heavily on synthetic interactions, yet the realism of these simulations is not validated against real clinical practice or human experts. Thus, it remains unclear whether the reported improvements would transfer beyond the simulated environment.
-
The same LLM family is used for reward computation and final evaluation, raising concerns that the learned policy may be optimized toward the preferences of the judge model rather than toward improved clinical reasoning. While the paper includes limited validation of the judge, the current evidence is insufficient to eliminate this concern.
-
Additional concerns include the reliance on ground-truth diagnoses during synthetic data generation, the lack of detailed error analysis, insufficient validation of the proposed patient personas and examination noise models, and the absence of human or clinician evaluation to verify the realism of the generated interactions.
To sum up, while I find the problem important and the proposed direction promising, I am not convinced that the current experimental evidence sufficiently supports the paper's central claims of robust interactive diagnosis in realistic, noisy clinical settings. Therefore, the paper is not ready for publication before rebuttal.
The rebuttal would be most helpful if it can clarify any misunderstandings regarding the evaluation protocol, the role of the LLM judge, and the construction of the synthetic training environment. However, if the reviewers' understanding is correct, the principal concerns relate to the realism and validity of the evaluation methodology itself. In particular, stronger evidence demonstrating robustness under noisy conditions, validation of the simulated clinical environment, and independent evaluation (e.g., clinician assessment or alternative judges) would substantially strengthen the work, but these issues are unlikely to be fully addressed during the rebuttal period.
Final justification
The authors addressed most of the reviewers’ concerns during the rebuttal, which convinced me to recommend acceptance.
1 comment
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 4/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper formalize interactive clinical diagnosis as a POMDP in which a single agent chooses among three actions, ask the patient a free-form question, order an exam, or commit a final diagnosis, under stochastic observation noise and explicit cost. Disease is fixed per episode, so all uncertainty lives in the observation function. The agent is trained in two stages: SFT on synthetic doctor–patient dialogues structured by the Calgary–Cambridge interview model, then DAPO RL against a composite reward combining a Jaccard-based diagnosis score, a multiset tool-matching term, and a cost penalty grounded in CMS fee schedules plus a three-tier invasiveness taxonomy. The headline empirical claims are large in-distribution gains over seven baselines and, more notably, statistical parity with a 70B model out-of-distribution despite an order-of-magnitude size gap. Ablations identify the cost penalty as the load-bearing design choice.
Strengths and weaknesses
Strengths
- Per-exam cost is anchored to CMS fee schedules plus a three-tier invasiveness taxonomy. Most work in this space either ignores cost or uses an arbitrary scalar; the ablation identifies this term as the load-bearing design choice.
- The environment is a reusable artifact. Exam calls return findings recorded in the source cases rather than LLM-generated text, dialogue is structured by the Calgary–Cambridge model, and personas are drawn from PatientSim. Code, checkpoint, environment, and hyperparameters are released.
- An 8B model statistically tied with a 70B specialist OOD. Under application criteria this matters as an on-premise feasibility result, not only as a performance number.
- Questioning, exam ordering, and diagnosis within one episode, which conversation-only and exam-only systems leave separated.
Weaknesses
- Overall framework based on closed LLM loop, without human validation.
- Cost is never compared to a reference. The paper's central design choice is a cost penalty, yet Table 3 reports only average call count, and no comparison of aggregate cost against baselines or against the recorded ground-truth workup.
- The environment cannot credit improvements over the recorded trajectory. Non-GT exams return "No significant findings," so alternative workup strategies are undiscoverable by construction.
- The same judge family scores both the RL reward and the test metric.
Questions
- The paper makes patient personas a headline realism feature, but there is no experiment isolating their effect. A with-vs-without-persona comparison plus accuracy broken down by persona type would be needed to actually show what personas contribute.
- Call count is a weak proxy for cost. Table 3 reports average Calls but no aggregate cost, so the real cost change is unanswered.
- Reward assumes the GT exam list is optimal. The reward assumes the GT exam list is optimal and can't credit beating it. Since Rtool is anchored to GT recall (and non-GT exams return "No significant findings"), a strategy that reaches the correct diagnosis with fewer exams than GT gets no credit.
- There's no sweep over noise strength or test-time robustness curve.
Limitations
Same as above.
Final justification
I raise my rating from 4 to 5. The authors ran every experiment I requested and reported results that do not uniformly favor them, notably a null persona effect against their own headline realism claim, correctly reframed as simulator diversity. The held-out false-negative sweep supplies the missing test-time robustness evidence, the aggregate-cost table against baselines and the recorded workup (1.11× GT, best cost per correct diagnosis) supports the central design choice, and the training judge sitting mid-range in permissiveness rather than at their model's optimum resolves my judge-independence concern. My "no credit" phrasing on R_tool was inaccurate and their correction stands. The absence of clinician evaluation remains a real limitation, but the central claim concerns diagnosis in a defined environment with fixed reference labels and recorded exam findings, and under use-inspired criteria the released environment, CMS-grounded cost model, and 8B/70B OOD parity are a solid contribution. I ask that the camera-ready carry through the promised revisions.
Formatting concerns
N/A
5 comments
Rebuttal
We thank the reviewer for their valuable review of our paper. As of the start date of the author-reviewer discussion window, the experiments needed for this rebuttal haven't finished yet. We apologize for this delay and we will follow up with the full rebuttal within the next 1-2 days.
We thank the reviewer for their feedback on our work. We address each weakness and question as follows.
Weakness 1:
Please refer to Reviewer 2wK8 Weakness 2 for the scope of our diagnostic claim, and Reviewer Uw3M Weaknesses 2 and 6 for the respective roles of simulation realism and human evaluation.
Weakness 2:
Please refer to Reviewer Uw3M Weaknesses 4–5 and Reviewer 2wK8 Weakness 4 for the independent-judge validation and judge-swap results.
Weakness 3 / Question 3:
Thank you for raising this point. We clarify that does not assume that the ground-truth exam list is globally optimal. It uses the examinations recorded in the source case as reference-trajectory supervision, similar in role to imitation learning. The diagnosis reward supervises the final answer, while provides intermediate supervision for learning which examinations obtain the supporting evidence.
A trajectory using fewer examinations than the reference does not receive “no credit.” If its diagnosis is correct, it receives the full diagnosis reward, as well as partial based on its overlap with the reference examinations. The cost term separately discourages unnecessary examinations. This design intentionally balances learning from observed clinical trajectories with diagnostic correctness and efficiency.
Our existing ablation supports this choice. Removing reduces the average number of calls from 3.75 to 2.38 on DDxPlus and from 4.03 to 1.99 on PMC, but also reduces diagnostic performance: Jac falls from 0.937 to 0.930 on DDxPlus, from 0.345 to 0.219 on PMC, and from 0.378 to 0.266 on AgentClinic. Thus, diagnosis and cost rewards alone lead the model to under-examine rather than discover a better examination strategy. Our environment is designed to reconstruct and diagnose the source cases from their recorded evidence; we do not claim that their examination lists are globally minimal clinical workups.
Question 1:
Thank you for this suggestion. We first verify that persona conditioning changes the simulated patient as intended. Across 10,026 conversations, words per patient turn range from 78.8 (verbose) to 24.3 (plain), and medical-history disclosure is 0.349, 0.243 and 0.130 for high, low and no recall, respectively.
We then remove the persona section and re-run both MedExAgent and the size-matched Qwen3-8B baseline on the same PMC cases, holding all other settings fixed:
| model | n | Jac, on → off | Δ (paired p) | strict Acc, on → off | Δ (paired p) |
|---|---|---|---|---|---|
| MedExAgent-8B | 2,418 | 0.3390 → 0.3356 | −0.0034 (0.634) | 0.3098 → 0.3118 | +0.0021 (0.816) |
| Qwen3-8B | 990 | 0.0895 → 0.1076 | +0.0181 (0.054) | 0.1152 → 0.1374 | +0.0222 (0.067) |
Neither model has a significant persona effect, and the difference between their effects is also not significant (Jac p=0.370; strict Acc p=0.801). Accuracy broken down by personality, language proficiency and history recall likewise shows no significant difference for MedExAgent or three baselines on the same 1,000-case pool (all p≥0.224).
Thus, personas produce the intended differences in patient communication, but are not a demonstrated diagnostic-difficulty factor in our current environment. We will revise the paper to describe their contribution as simulator diversity.
Question 2:
Thank you for this suggestion. We sum the cost and discomfort scores of all examinations ordered in each PMC episode and report the average aggregate cost:
| Table 3 variant | n | calls (re-run) | aggregate cost |
|---|---|---|---|
| MedExAgent-8B | 1,000 | 4.03 | 12.67 |
| w/o tool-match () | 2,418 | 2.19 | 7.11 |
| w/o cost penalty () | 2,418 | 9.69 | 32.88 |
Removing the cost penalty increases the number of calls by 2.40× but aggregate cost by 2.60×, because the model also orders more expensive examinations. Thus, call count slightly understates the cost increase. We will add aggregate cost to Table 3.
Question 4:
We thank the reviewer for this point. Please refer to our answer to Weakness 1 by Reviewer 2wK8.
Thank you for a thorough rebuttal. You ran every experiment I asked for, with detailed analysis. I am raising my rating from 4 to 5.
Resolved.
- The manipulation check plus the on/off comparison answers my question, and reframing personas as simulator diversity is the correct conclusion. Please carry this into the paper as promised.
- The 2.40× calls vs 2.60× cost gap makes the point that call count understates cost. Please do add this to Table 3.
- Using a held-out false-negative operator to avoid leakage and analysis is helpful.
- My "no credit" phrasing was inaccurate and your correction stands. I now read R_tool as reference-trajectory supervision, which is a reasonable application-appropriate choice.
- The observation that your training judge sits mid-range in permissiveness rather than at your model's optimum addresses my concern for the main comparisons.
Where I still see an issue.
- Removing the consultation channel entirely costs 0.011 Jaccard, and personas have no significant effect on accuracy. Taken together, diagnostic information in this environment resides almost entirely in the examination stage. Your upper-bound argument is fair on its own terms, but this is inverted relative to real encounters, where history-taking carries most of the diagnostic yield. I would like to see this stated directly in the paper rather than left to the reader.
- The aggregate-cost table compares your ablations to each other. For a paper whose central design choice is a cost penalty, the number that matters for the intended application is cost relative to the baselines and to the recorded ground-truth workup. Could you add that?
- (minor) Sample sizes are inconsistent across your rebuttal tables, with n across 990 / 1,000 / 2,418. I assume these are different subsets. please unify them in camera-ready.
- Rating
- 3/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper introduces MedExAgent, an 8B medical LLM agent for clinical diagnosis. The agent does not only answer a final medical question. It can ask the patient questions, order medical exams, and then give a diagnosis. The paper build this as a POMDP environment. They also add patient noise, exam noise, patient personas, and exam costs. The model is trained in two steps. First, it is fine-tuned on synthetic doctor-patient conversations. Then it is trained with reinforcement learning to improve diagnosis accuracy, tool use, and exam cost. The experiments show that MedExAgent performs well on DDxPlus, PMC-Patients-v2, and AgentClinic-MedQA. It is competitive with much larger models and uses exams in a more cost-aware way.
Strengths and weaknesses
Strengths
- The paper studies a real and important problem. Diagnosis is usually not one simple question. A doctor needs to ask the patient questions, order exams, and then make a decision. This paper tries to model that full process.
- The method is reasonable and easy to follow. The agent is trained with SFT first, then RL. The reward does not only check if the diagnosis is correct. It also checks tool use and exam cost, which is a good idea.
- The experiments are helpful. The paper compares the model with several other LLMs. Some baselines are much larger models. The ablation study is also useful because it shows which parts of the method help the final result.
Weaknesses
- This paper talks a lot about noisy clinical settings, but the main test does not include noise. The paper says, “noise is not included in the test sets” to make comparison fair. I understand this choice, but it makes the main claim weaker. Since the title and motivation focus on noisy clinical environments, the paper would be better to test the model with noisy patient answers and noisy exam results. It would be helpful to show results at different noise levels.
- The paper depends a lot on synthetic data. The doctor-patient conversations are generated by LLMs. The RL environment also uses LLM-based patient simulation. This is useful for scaling, but real patients may behave very differently. They may give unclear answers, forget details, or describe symptoms in unusual ways. The authors should add some human or clinician evaluation to check if the conversations and decisions are realistic.
- I am also concerned about the hidden diagnosis used during data generation. The paper says the doctor prompt includes “HIDDEN CANONICAL DIAGNOSIS” and tells the doctor that the final diagnosis “must match the hidden canonical diagnosis exactly.” This may make the training conversations too guided. In real diagnosis, the doctor does not know the answer first. The authors should test what happens if the training conversations are generated without giving the doctor the true diagnosis.
- The evaluation relies heavily on an LLM judge. The diagnosis reward uses an LLM judge, and the evaluation also uses an LLM judge for Jaccard and accuracy. This may make the model better at matching the judge, not necessarily better at real medical diagnosis. The paper does verify the judge to some degree, but this is still limited. A better evaluation would include another judge model and clinician review.
- The OOD results are promising, but not fully convincing. On AgentClinic-MedQA, MedExAgent is close to Aloe-Beta-70B, but it does not clearly beat it. So the claim that the 8B model matches larger models is reasonable. But the paper should be more careful when suggesting strong OOD improvement. The result is more like competitive performance than clear superiority.
- The paper lacks a detailed error analysis. The paper includes useful ablations, but they do not analyze where MedExAgent fails. For example, it is unclear whether wrong diagnoses come from asking poor questions, ordering the wrong exams, misunderstanding exam results, or making a bad final diagnosis. It would help to include examples of failed cases and group errors by disease type, tool-use mistake, and safety risk.
Questions
see Weaknesses
Limitations
No.
The authors do mention some useful limitations. They discuss simulated patients, English-only data, and the assumption that the patient condition does not change over time.
But I think some important limitations are still missing. The paper should more clearly say that noise is used in training, but the main evaluation is still on clean test sets. Since noisy clinical environments are a main motivation, this should be discussed as a limitation.
The paper should also discuss more risks from using LLM-generated patients and an LLM judge. These choices make the experiments scalable, but they may not reflect real clinical behavior or real medical correctness.
Final justification
After reading the rebuttal, I improved my Quality score because the new experiments and error analysis addressed several of my concerns. I still feel the evaluation needs more work, especially around the simulated conversations and the use of LLM judges.
Formatting concerns
I did not notice any major formatting or anonymity issues.
2 comments
Rebuttal
We thank the reviewer for their constructive comments. We address each concern below.
Weakness 1:
We thank the reviewer for this insightful idea. We agree that including test-time noise in evaluation is helpful in demonstrating our claims. Since applying the same noise types during training would form noise leakage, here we evaluate the model using another type of noise, which is simply removing the findings of the exams. We call this noise "false-negative".
Specifically, for each experiment, we remove the findings of each exam with a probability of α. We sweep a series of values for α from 0 to 1. In realistic clinical scenarios, the typical value is 0.035, and the high end is 0.078 [K1–K3]. We run this experiment on PMC-Patients-v2:
| false-negative rate α | MedExAgent Jac | Δ vs clean | w/o noise injection | gap |
|---|---|---|---|---|
| 0 (clean) | 0.339 | — | 0.262 | +0.077 |
| 0.035 — literature operating point | 0.329 | −0.010 | 0.264 | +0.065 |
| 0.078 — high end of published ranges | 0.337 | −0.002 | 0.257 | +0.080 |
| 0.25 | 0.311 | −0.028 | 0.235 | +0.076 |
| 0.50 | 0.280 | −0.059 | 0.225 | +0.055 |
| 1.0 | 0.213 | −0.126 | 0.151 | +0.062 |
From the results, we can observe that first, at the rates at which real imaging actually misses findings, accuracy is essentially unchanged (−0.010 and −0.002). Second, degradation beyond that range is gradual. The agent does not have a brittle failure point inside the plausible range. Third, the no-noise ablation variant sits below MedExAgent at every level. This is because when trained with noise, MedExAgent learns to avoid over-relying on individual exam results, which improves the model performance at all noise levels.
Weakness 2:
We agree that clinician evaluation would be necessary to claim that our simulated conversations reproduce real clinical encounters, or that the resulting agent is ready for patient-facing use. However, we clarify that we make neither claim in this paper. This paper studies diagnostic performance in a defined interactive environment. Realism is a design motivation for that environment, not the endpoint being evaluated. Specifically:
-
Diagnostic performance is verifiable without first establishing that the conversation looks realistic to a human. The diagnosis for each episode is fixed before the interaction and comes from the source case. The simulator only mediates how the agent obtains the case information. The agent's final diagnosis can therefore be compared with a fixed reference diagnosis independently of whether a clinician finds the dialogue natural. Human review of transcript realism and verification of diagnostic correctness answer different questions, and the latter is the question required by our central claim.
-
Our target is better diagnosis in the defined environment, not a realistic simulation of a physician or consultation. MedExAgent is trained to choose among asking, ordering an exam, and diagnosing under the POMDP specified in the paper. Accordingly, the relevant validation is whether the environment supports a non-trivial diagnostic task and whether improvements transfer beyond the exact training loop. Our main results demonstrate that the diagnostic performance of our model is competitive across benchmarks, and we do not present it as evidence of real-world clinical validity.
We will revise Section 4 to clarify this point.
Weakness 3:
We thank the reviewer for this question.
To begin with, the hidden canonical diagnosis is only used in the prompt for conversation generation in order to make sure the generated conversation does not diverge from the ground truth diagnosis. As we show in the experiment below, without the target, a teacher can follow an early differential away from the source diagnosis, after which its questions, exam choices and final answer no longer describe the example whose findings supplied the trajectory.
Furthermore, using a known target to synthesize the path leading to it is a common pattern in synthetic supervision. For example, STaR gives the teacher the correct answer when generating a rationale for a failed problem, then removes that hint from the example used for finetuning (Zelikman et al., NeurIPS 2022) [K4].
We tested whether the diagnosis is in fact needed for consistency. We sampled 60 PMC cases with a fixed random seed, and generated the same 60 PMC cases twice, holding the case, tools, simulators and turn limits fixed, and changing only whether the teacher sees the source diagnosis:
| teacher sees diagnosis | teacher does not | |
|---|---|---|
| final diagnosis matches exactly | 98.3% | 3.3% |
| final diagnosis correct under LLM judge | 100% | 60% |
| judge Jaccard | 1.000 | 0.560 |
We can observe that when the ground truth diagnosis is not given, 40% of the generated conversations end with a medically different diagnosis and only 3.3% preserve the source label closely enough to pass the generation gate. Training on these trajectories would introduce contradictory rather than less-guided supervision.
In conclusion, we agree that this experiment is an interesting ablation study, and we will add it in our appendix.
Weakness 4:
Thank you for raising this point. Please refer to our response to Weaknesses 4 and 5 raised by reviewer Uw3M.
Weakness 5:
We thank the reviewer for this point. To our understanding, the interpretation that you recommend (competitive performance rather than OOD superiority) is already the claim made in the submission. We do not claim that MedExAgent outperforms Aloe-Beta-70B on AgentClinic: the abstract says "comparable to larger models," Figure 1 says "matches much larger baselines," and Section 6.1 says "statistically tied with the 70B Aloe-Beta." Table 1 reports 0.378 versus 0.395 Jac, with no significant difference (p=0.681). The judge-free embedding metric [K7] gives the same conclusion (p=0.326). We will revise Section 6.1 to avoid this confusion.
Weakness 6:
We thank the reviewer for this insightful idea. We have added a new error analysis section to the appendix of our paper. The results are shown as follows.
We first analyze the failure mode in terms of conversation stage. Specifically, we prompt GPT-5.5, claude-sonnet-5, and GPT-4.1-mini to classify which of the four stages in our conversation resulted in the final error. We report the majority vote results from the three judges:
| primary failure stage | PMC (n=692) | DDxPlus (n=50) | AgentClinic (n=125) |
|---|---|---|---|
| exam selection | 50.7% | 26.0% | 52.8% |
| final reasoning | 29.3% | 52.0% | 28.8% |
| exam interpretation | 13.3% | 6.0% | 12.8% |
| questioning | 5.8% | 16.0% | 5.6% |
| label or evidence inconsistency | 0.7% | 0.0% | 0.0% |
We can see that for PMC and AgentClinic, most errors are due to exam selection. This is expected since exam selection is the most impactful and hardest step to do among all. In DDxPlus, since the cases are relatively easier, exam selections only makes 26.0% of error cases while final reasoning goes to the main reason.
Furthermore, to analyze the detailed reasons for failures, we sampled 100 failure cases across three datasets and manually read over them to form a summarized taxonomy of failures. We thrn prompt GPT-5.5 to classify all the failure cases into these categories. The results are shown as follows:
| induced failure mode | PMC | DDxPlus | AgentClinic | overall |
|---|---|---|---|---|
| Insufficient examination | 26.9% | 10.7% | 39.2% | 27.6% |
| Incidental anchoring | 16.9% | 30.4% | 12.0% | 17.1% |
| Pattern synthesis | 10.8% | 30.4% | 19.2% | 13.3% |
| Evidence misread | 15.2% | 8.9% | 10.4% | 14.1% |
| Negative-evidence mishandling | 11.0% | 0.0% | 6.4% | 9.6% |
| History omission | 7.4% | 14.3% | 8.0% | 7.9% |
| Specificity failure | 6.2% | 1.8% | 4.0% | 5.6% |
| other | 5.6% | 3.6% | 0.8% | 4.8% |
We can observe that insufficient examination is the most prevalent failure pattern, which is consistent with our conversation stage examination. We also collapsed our taxonomy into the one studied in [K8], which gives the following table:
| diagnostic process stage | MedExAgent (n=873) | human physicians [K8] (n=583) |
|---|---|---|
| Testing: ordering, processing, and acting on results | 43.9% | 44% |
| Clinician assessment | 42.5% | 32% |
| History taking | 4.6% | 10% |
| Physical examination | 7.4% | 10% |
| Other | 1.6% | 3% |
We can see that the main error types of MedExAgent match well with that of human physicians. This can be explained by the fact that exam ordering is the most mistake-prevalent task in clinical diagnosis practice.
Limitations:
The reviewers mentioned two items here: the first is about evaluation with noise, which we address in Weakness 1. The second is about risks from using LLM-judge and a simulated environment for training. In Weakness 2, we clarified that MedExAgent is not trained to imitate real doctor behavior, but improving diagnostic performance. This is also a valid limitation of the model, which we'll revise our Limitations section to discuss.
[K1] Bradley et al. Chest X-ray Sensitivity and Lung Cancer Outcomes: A Retrospective Observational Study. Br J Gen Pract 71.712 (2021): e862-e868.
[K2] Alhammami. Diagnostic Accuracy of CT vs MRI in Detecting Metastases in Colorectal Cancer. Cureus 16.8 (2024): e66125.
[K3] Lin et al. Preanalytical Phase Errors Constitute the Vast Majority of Errors in Clinical Laboratory Testing. Clin Chem 70.S1 (2024).
[K4] Zelikman et al. STaR: Bootstrapping Reasoning With Reasoning. NeurIPS 35 (2022).
[K5] Zhang & Bansal. Addressing Semantic Drift in Question Generation for Semi-Supervised QA. EMNLP-IJCNLP (2019): 2495-2509.
[K6] Sennrich et al. Improving Neural Machine Translation Models with Monolingual Data. ACL (2016): 86-96.
[K7] Balachandran. MedEmbed: Medical-Focused Embedding Models (2024). github.com/abhinand5/MedEmbed
[K8] = [U1].
Dear Reviewer 2wK8,
Thank you again for your time and thoughtful comments. As the author-reviewer discussion period will close soon, we would greatly appreciate it if you could take a moment to review our rebuttal. We believe that our added experiments directly address your concerns, and we would be grateful if you could reconsider your initial assessments in light of these additional results. We would also be happy to provide any further clarification if needed.
- Rating
- 3/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper presents MedExAgent, an 8B-param agent for medical diagnosis. Unlike the conventional medical LLMs and methods which largely make diagnosis with single-turn question answering. This agent make diagnosis interactively following POMDP. The authors also consider the existence of noise during interaction between the doctor and the patient by modeling the patient noise and the exam noise. The training of the agent is supervised through conversations conforming to Calgary-Cambridge model.
Strengths and weaknesses
Pros MedExAgent uses agentic approach to do medical diagnosis. This is a step forward comparing to the existing work on single-turn question answering methods since it is more similar to the real scenario.
Cons
- The author uses 7 patient personas as patient noise. However, the alignment between the patient personas and the real patient responses are not verified.
- The training data is generated via LLM simulation of the conversation between the doctor and the patient. However, how the conversation align with the real scenario is not verified. Such domain shift may make the agent work in simulation environment but break down in the real-life environment.
- The exam noise is mostly from artificial perturbation. It would be better to include the noise based on medical research since it will be much more aligned with the real scenario.
- The author employs gpt-4.1-mini as the LLM-judge for diagnostic accuracy evaluation. I wonder if the mini model can accurately evaluate the results given the existence of sota models like gpt-5. Even though Appendix C includes a small-scale experiments on its accuracy, it is not strong enough to exclude such doubt given the size of the constructed samples.
- It seems the reward calculation is based on gpt-4.1-mini, the same model used in diagnostic accuracy evaluation. This might cause overfitting bias towardthe perfromance of MedExAgent.
- The paper lacks a dedicated human expert evaluation, which is essential for medical diagnostic task.
Questions
- Is it possible to verify the alignment between the simulated patients (including the persona variety) and the real patient?
- Is it possible to include exam noise endorsed by existing medical research rather than using artificial perturbation?
- Is it possible to have a sota model to do the LLM-judge work, and invite a human expert to evaluate the accuracy of the judge.
Limitations
yes
Final justification
Thanks for the detailed rebuttal! It has addressed most of my concerns, especially the weakness 1, 2, 3, 4 and 5. My remaining suggestion would be adding the narrowed scope regarding clinical realism discussed in the rebuttal weakness 2 to the paper's limitation section.
Formatting concerns
The values in the last rows of Table 1 and 2 are not well aligned.
2 comments
Rebuttal
We thank the reviewer for a careful review. We address the concerns by point as follows.
Weakness 1:
Thank you for raising this. We believe there is a conflation here that we are using 36 patient personas instead of 7, as stated in Section 4.2.
Regarding the verification of patient personas against real patients, in the PatientSim paper [21], the authors did a detailed expert evaluation and demonstrated the realism of the proposed patient personas. In this paper, we directly apply their taxonomy as a verified structure for realistic patient persona simulation. We agree that this part is currently not clearly stated in the paper, and we will revise Section 4.2 to clarify.
Weakness 2:
We thank the reviewer for this insightful point. We agree that aligning with real-life environments is a crucial part for medical agents. We would like to clarify that realism only plays a limited part in the task and environment of MedExAgent, and similar settings have been widely applied in previous works. The details are as follows.
-
The examination stage has no simulation gap at all. An exam in our environment is a tool call, and the value returned is not generated by an LLM. Instead, it is the findings text recorded in the source case. For example, in PMC-Patients-v2, those are the exams a clinician actually performed on a real patient and the findings actually reported in the published case report.
-
The examination stage is where essentially all of the diagnostic information lives. We test the usefulness of the conversation stage and the exam stage. Specifically, we ablate each of them by removing all the useful information from that stage. The results are shown as follows:
| condition | Jac | Acc | EmbedSim |
|---|---|---|---|
| clean | 0.339 | 0.310 | 0.628 |
| patient withholds every symptom, location, and timing detail | −0.011 | −0.005 | −0.005 |
| every ground-truth examination returns a negative | −0.126 | −0.112 | −0.047 |
| both | −0.142 | −0.127 | −0.058 |
We can see that destroying the consultation channel entirely moves accuracy by 0.011 Jac. This is a measured upper bound of simulation error, since no degree of patient-simulator unrealism can shift our conclusions by more than that.
-
For the part that is simulated, we adopt a framework that has itself been clinician-validated. Our 36 patient personas are taken from PatientSim [21]. In the PatientSim paper, the authors conducted a comparison study of the patient personas against real patients. We refer the reviewer to their paper for details.
-
These choices are at or above the standard in comparable work. On the exam side, returning the recorded result is the established design. For example, AgentClinic [35] uses a dedicated measurement agent to return exam results. On the patient side, the norm is a plain LLM conditioned on the case record with no persona modelling at all: MediQ [24] simulates the patient by having an LLM answer from a parsed patient record, and AI Hospital's Patient NPC is conditioned directly on the medical record.
Weakness 3:
We thank the reviewer for this point. We clarify that our noise taxonomy is derived from a very common understanding of clinical error classification. There is not a single unified framework for error classification in medical research, but many previous works propose their own framework that repeatedly distinguish missing, incorrect or misinterpreted, and uncertain information. For example, DEER separates failure to elicit information from inaccurate, misinterpreted or overlooked information [U1], while Kim-Mansfield distinguishes under-reading, faulty reasoning and satisfaction of search in radiology [U2]; radiology-reporting research separately studies equivocal or hedged findings [U3]. These provide medical precedents for our omission, substitution and ambiguity operators that we use. We will revise Section 4.2 to include a description of how we come up with our noise taxonomy.
Additionally, the patient operators we use also align with taxonomies from the medical-AI literature. Recent work defines clinically grounded taxonomies of difficult patient behaviour: information contradiction, factual inaccuracy, self-diagnosis and care resistance in one [U5], and a five-dimension decomposition into logic consistency, health cognition, expression style, disclosure and attitude in another ([U6]).
Weakness 4
We thank the reviewer for raising this point. In order to further verify the performance of the gpt-4.1-mini judge, we did another larger validation run with 2,664 (ground-truth diagnosis, predicted diagnosis) pairs saved from our evaluation run, spanning MedExAgent, our no-noise ablation and the Aloe-8B baseline, on PMC-Patients-v2 and AgentClinic. These represent the actual workload for the judge during evaluation. We re-scored every saved prediction with three recent models. The results are shown as follows:
| gpt-4.1-mini vs | agreement | Cohen's κ |
|---|---|---|
| gpt-5.5 | 93.98% | 0.834 |
| claude-sonnet-5 | 94.22% | 0.844 |
| qwen3.6-35b-a3b | 96.02% | 0.899 |
This demonstrates that gpt-4.1-mini has high agreement with recent models in this judging task. We will revise our judge validation section to reflect this result.
Weakness 5:
We thank the reviewer for this question. To begin with, as we discuss in our response to Weakness 4 by Reviewer 2wK8, the task of the LLM judge here is to act as a verifier that compares the predicted diagnosis label with the ground truth. The main purpose of using an LLM judge rather than exact match is to cover cases such as comparing "Diabetes type II" and "Early-stage Type II Diabetes". Therefore, this task requires more of grammatical and basic medical common sense rather than clinical knowledge, and the space for reward hacking is very limited.
Nevertheless, we agree with your point that using the same model for reward and judgement is non-standard. To address this point, we supplement our main result table with a judge verification experiment that applies three judge models (GPT-5.5, claude-sonnet-5, and qwen3.6-35b-a3b), using our judge prompt verbatim:
| model / set | gpt-4.1-mini | gpt-5.5 | claude-5 | qwen3.6 |
|---|---|---|---|---|
| MedExAgent — PMC | 0.337 | 0.248 | 0.267 | 0.359 |
| w/o noise injection — PMC | 0.253 | 0.219 | 0.226 | 0.259 |
| Aloe-8B — PMC | 0.114 | 0.110 | 0.118 | 0.132 |
| Qwen3-32B — PMC | 0.110 | 0.088 | 0.131 | 0.125 |
| MedExAgent — AgentClinic | 0.359 | 0.261 | 0.281 | 0.407 |
| w/o noise injection — AgentClinic | 0.358 | 0.309 | 0.313 | 0.358 |
We can observe that the four judges differ mainly in how permissive they are—the fraction of pairs each calls a match runs gpt-5.5 0.243 < claude 0.257 < gpt-4.1-mini 0.345 < qwen 0.365—and our training judge (gpt-4.1-mini) sits in the middle of that range, not at MedExAgent's optimum. This confirms that the reward hacking in our experiment is minimal and does not affect our conclusions.
Weakness 6:
We thank the reviewer for this point. If the concern is whether diagnostic answers are scored correctly, this is addressed in Weakness 4 through agreement with three independent judges. If the concern is whether the simulated conversations are realistic, this is addressed in Weakness 2. These are distinct evaluation targets, and the corresponding evidence is reported there.
Question 1 — "Is it possible to verify the alignment between the simulated patients (including the persona variety) and the real patient?"
Please refer to our response to Weakness 1 and point 3 in our response to Weakness 2.
Question 2 — "Is it possible to include exam noise endorsed by existing medical research rather than using artificial perturbation?"
Please refer to our response to Weakness 3. We also evaluated our model with clinical false-negative noise at a rate shown in medical research. Please refer to our response to Weakness 1 by Reviewer 2wK8 for this part.
Question 3 — "Is it possible to have a sota model to do the LLM-judge work, and invite a human expert to evaluate the accuracy of the judge?"
Please refer to our response to Weakness 5.
Paper formatting concerns — "The values in the last rows of Table 1 and 2 are not well aligned."
We thank the reviewer for catching this. We will fix it in the camera-ready version.
[U1] Schiff et al. Diagnostic Error in Medicine: Analysis of 583 Physician-Reported Errors. Arch Intern Med 169.20 (2009): 1881-1887.
[U2] Kim & Mansfield. Fool Me Twice: Delayed Diagnoses in Radiology. AJR 202.3 (2014): 465-470.
[U3] Callen et al. Between Always and Never: Evaluating Uncertainty in Radiology Reports Using NLP. J Digit Imaging 33.5 (2020): 1194-1201.
[U4] Fan et al. AI Hospital: Benchmarking LLMs in a Multi-agent Medical Interaction Simulator. COLING (2025): 10183-10213.
[U5] Li et al. Beyond Idealized Patients: Evaluating LLMs under Challenging Patient Behaviors. arXiv:2603.29373 (2026).
[U6] Luo et al. MedDialBench: Benchmarking LLM Diagnostic Robustness under Adversarial Patient Behaviors. arXiv:2604.06846 (2026).
Dear Reviewer Uw3M,
Thank you again for your time and thoughtful comments. As the author-reviewer discussion period will close soon, we would greatly appreciate it if you could take a moment to review our rebuttal. We believe that our added experiments directly address your concerns, and we would be grateful if you could reconsider your initial assessments in light of these additional results. We would also be happy to provide any further clarification if needed.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We thank the AC for summarizing the reviewers' concerns.
Test-time robustness under noise. This was raised by all three reviewers. The shared concern is that noise is used during training, while the main results are on clean test sets and do not show how performance changes with noise severity. We therefore add a test-time dose-response experiment using false-negative examination findings, an operator not used during training, and set its clinically plausible range from published miss rates. On PMC, Jac changes by only −0.010 and −0.002 at the two literature-derived rates, then degrades gradually to −0.126 when every positive finding is removed. The no-noise training ablation remains below MedExAgent throughout the sweep. We will state explicitly that the main tables use clean test sets and use this new curve, rather than the clean results, as the evidence for test-time noise robustness.
Validation and scope of the simulated environment. This was also mentioned by all three reviewers. The concern combines two different questions: whether the final diagnosis can be evaluated reliably, and whether the dialogue reproduces a real clinical encounter. Our central claim concerns the first. Each episode has a fixed diagnosis and source-case evidence, so diagnostic correctness is verifiable without a clinician first judging transcript realism. The clinical findings themselves come from published cases or physician-curated data; the LLM simulates how that information is disclosed.
We nevertheless add checks on the simulated component. The persona manipulation check confirms that the intended communication and recall behaviours change, while the with/without-persona experiment and the same breakdown on three baselines show no material change in diagnostic accuracy; we therefore describe personas as simulator diversity, not a demonstrated difficulty axis. Swapping the patient-simulator family also leaves diagnostic accuracy unchanged on PMC and AgentClinic. These results support diagnosis in the defined environment, but they are not a substitute for clinical validation of realism. We will narrow the claim accordingly and identify clinician transcript evaluation as future validation rather than imply patient-facing readiness.
Judge independence and reward hacking. This was raised by Reviewer Uw3M (Weaknesses 4 and 5 and Question 3), Reviewer 2wK8 (Weakness 4), and Reviewer yxWk (Weakness 2). The concern is that using the same model family for the training reward and final evaluation may favor outputs optimized for that judge. Here the judge performs a narrow verification task—whether the predicted and reference disease names denote the same diagnosis—rather than rating open-ended clinical reasoning. We re-score the saved predictions with three independent judges. Their verdict agreement with the training judge exceeds 94%, they preserve the same model ordering, and the training judge is not the judge that gives MedExAgent its highest score. A judge-free MedEmbed evaluation gives the same comparative conclusion. We therefore find no evidence of a judge-specific advantage, while acknowledging that absolute scores vary with judge permissiveness.
Ground-truth diagnosis during data synthesis. This was raised by Reviewer 2wK8 (Weakness 3). The concern is that exposing the generator to the diagnosis may over-guide the training trajectory. We clarify that the diagnosis is used only to keep the synthesized trajectory consistent with the fixed source case; it is not available to the trained agent during inference. In a paired 60-case generation experiment, removing it leaves conversation length unchanged but causes 40% of trajectories to end with a medically different diagnosis and only 3.3% to preserve the source label exactly. This shows that the target prevents supervision drift rather than leaking information to the deployed agent.
Detailed error analysis. This was raised by Reviewer 2wK8 (Weakness 6). The concern is that aggregate diagnostic accuracy does not show whether failures originate in questioning, exam selection, exam interpretation or final reasoning. We add both a stage-level analysis over all failures and a finer taxonomy induced from manually reviewed cases. The results identify exam selection as the main failure stage on PMC and AgentClinic and final reasoning as the main stage on DDxPlus, with detailed categories such as insufficient examination, incidental anchoring, evidence misreading and missed synthesis.
In summary, the rebuttal adds the missing noise curve, independent judges, simulator checks and error analysis, while narrowing the paper's claims where the evidence does not support clinical realism. The full experimental details and citations appear under the reviewer responses listed above. We believe that our rebuttal has covered the major concerns by the reviewers, and we would really appreciate it if you could reconsider your decision.