SSD: Shell-Guided Spherical Diffusion for Molecular Geometry Generation
Yunyen Chuang, Chen-Sheng Gu, Hung-Min Hsu, Kevin Lin, Ray-I Chang
NeurIPS 2026
TL;DR. SSD pairs a chemically scaled spherical shell with shell-aware drifts, fixing Gaussian-prior mismatch in molecular diffusion and improving five backbones with no added parameters.
Abstract. Diffusion models for 3D molecular geometry almost universally adopt an isotropic Gaussian prior, whose Frobenius-norm scale is governed by the noise level and atom count rather than by chemistry, so a per-atom scale mismatch with the data induces an absolute transport discrepancy that grows with , yielding high spatial entropy and unstable early trajectories. We introduce Shell-guided Spherical Diffusion (SSD), a model-agnostic framework that replaces the Gaussian prior with a chemically scaled spherical-shell initialization, augments the forward process with radial attraction toward the shell, and, for the score-based backbones, samples with a geometry-guided hybrid reverse process that combines radial attraction, short-range repulsion, and an SE(3)-equivariant correction field. This joint design of initialization and dynamics is essential: neither a shell alone nor radial fields alone reproduces the stability or accuracy of SSD. We evaluate SSD across five representative coordinate-space backbones—GeoDiff, SubGDiff, EDM, SemlaFlow-style flow matching, and MCF—each under its canonical evaluation protocol. SSD consistently improves both quality and diversity under identical training and sampling budgets, upgrading weaker backbones such as GeoDiff and EDM to match or surpass stronger diffusion-, VAE-, and flow-based baselines. SSD therefore serves as a plug-in geometric enhancement that strengthens coordinate-space molecular generation models without modifying their architectures, loss functions, or training pipelines.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:43 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper introduces Shell-Guided Spherical Diffusion (SSD), a geometry-aware modification of coordinate-space molecular generators. SSD replaces the conventional isotropic Gaussian prior with a dataset-calibrated spherical shell and augments the generative dynamics with radial guidance, short-range repulsion, and an SE(3)-equivariant learned correction.
Strengths. The reviewers broadly agree that the motivation is intuitive and meaningful. The paper questions a design choice (he physical scale of the terminal prior) that is often taken for granted and proposes a simple intervention that can be applied to several existing model families. The empirical evaluation is a major strength. SSD is evaluated with GeoDiff, SubGDiff, EDM, MCF, and a coordinate-space flow-matching implementation on both QM9 and Drugs. The paired comparisons consistently favor SSD, with particularly large improvements for GeoDiff, SubGDiff on Drugs, and EDM. The ablations, reduced-step evaluations, molecule-size stratification, trajectory metrics, and matched Gaussian-Flow control collectively provide substantial evidence that the shell geometry contributes beyond an encoder or capacity change.
Weaknesses. However, several issues must be clarified before the contribution can be confidently assessed.
The main concern is the theoretical status of the proposed forward and reverse processes. The forward drift directs each atom toward a randomly assigned shell point, whereas the reverse process uses an assignment-free inward radial field, reverse-only repulsion, and a learned score. The manuscript itself describes the resulting reverse dynamics as a hybrid construction that compensates for the absence of the point-specific forward drift at inference. This is a reasonable engineering design, but it is not evidently the exact reverse-time SDE of the stated forward process. The authors should therefore state precisely whether they claim an exact reverse-time construction, approximate marginal matching under specific assumptions, or a heuristic geometry-guided sampler.
A closely related issue concerns score training. Because the SSD conditional corruption kernel is non-Gaussian, the paper trains against a thin-shell Gaussian approximation centered on the deterministic SSD trajectory. It then states that the approximation bias is bounded by an KL gap. However, small KL divergence between marginal distributions does not generally imply small error between their score fields without additional smoothness or functional-inequality assumptions. The paper should either provide an explicit score-level argument or characterize the target as an empirically motivated approximation rather than a theoretically controlled score estimator.
The empirical evidence is broad, but the principal tables report point estimates without multi-seed uncertainty. This matters less for the largest improvements, but several claims of consistent improvement rely on small differences. For example, SSD-MCF improves Drugs COV-R from 84.70 to 85.37, whereas other improvements are much larger. Near-saturated stability and validity metrics may also be sensitive to run-to-run variation. Representative uncertainty estimates are necessary to determine whether the smaller gains are reproducible.
The manuscript should also narrow claims that SSD leaves architectures, losses, training pipelines, and cost unchanged. For the score-based backbones, the learnable denoiser architecture and algebraic loss form may be preserved, but SSD changes the corruption distribution, the analytic regression target, and the procedure used to sample training states. The paper states that these states are obtained by integrating a nonlinear forward process rather than using closed-form Gaussian corruption. For SSD-Flow, the encoder is also changed to an EDM-style coordinate encoder. These changes do not invalidate the contribution, and the Gaussian-Flow control helps isolate the shell effect, but the implementation and cost claims should be phrased accurately.
Finally, the single dataset-level shell remains a potential limitation under multimodal molecular-size distributions or genuine distribution shift. The current evaluations on QM9 and Drugs show that SSD can be separately calibrated to two substantially different datasets, and the molecule-size analyses are informative. They do not establish out-of-distribution robustness when the calibration distribution differs from the test distribution. This should be acknowledged clearly. New experiments on scaffolding, linker design, peptides, metals, or multiple additional datasets are not required during rebuttal, but the paper should distinguish demonstrated within-distribution robustness from untested transfer.
The rebuttal should prioritize the following questions:
- What is the precise theoretical claim about the reverse process? Is it the exact reverse-time SDE of the proposed forward dynamics, an approximation to the forward marginals, or a hybrid heuristic sampler? If a marginal-consistency bound is claimed, please state its assumptions and explain whether it includes angular dynamics, permutation marginalization, the learned score, and reverse-only repulsion.
- What does the thin-shell KL result imply about the score target? Please either derive a score-error or denoising-risk bound under explicit regularity assumptions, or revise the paper to describe the Gaussian target as an empirically effective approximation.
- Are the reported improvements reproducible across seeds? Please provide mean and standard deviation or confidence intervals for representative paired comparisons, including at least one large-gain setting and the smaller MCF and SSD-Flow gains. Clearly identify any results that remain single-run.
- How are training corruptions generated, and what actually remains unchanged? Please specify the numerical integrator, number of evaluations per sampled time, whether trajectories are generated online or cached, and the measured training overhead relative to closed-form Gaussian corruption. Please also distinguish the unchanged denoiser backbones from the encoder modification in SSD-Flow.
The novelty is moderate, but a simple and reusable geometric intervention can still be a valuable contribution when supported by sufficiently strong evidence. If the authors appropriately narrow or justify the theoretical claims, clarify the implementation and cost, and establish that the main paired improvements are statistically reliable, I would be prepared to support acceptance. In its current form, the paper remains borderline because the empirical contribution appears considerably stronger than the theoretical formulation used to justify it.
Final justification
After considering the rebuttal and the reviewer discussion, I maintain my Accept recommendation.
The authors addressed the main conditions identified in the meta-review. First, they substantially narrowed the theoretical claims: the reverse process is no longer presented as an exact reverse-time SDE, the unsupported marginal-consistency bound is withdrawn, and the score-based variants are more accurately characterized as geometry-guided hybrid samplers with empirically demonstrated radial stability. The actual training kernel has also been stated explicitly: conditioned on the sampled shell targets, the implemented corruption kernel is Gaussian and its regression target is the corresponding exact conditional score.
Second, the empirical evidence was strengthened considerably. Three-seed experiments support the main improvements for SubGDiff, EDM, and the flow-based variant, while the smaller MCF-Drugs improvement is appropriately identified as not statistically significant. Additional ablations show similar component-level trends across another dataset and additional backbones, and sensitivity and multimodal-radius experiments further clarify the scope and limitations of the method.
I take seriously Reviewer M1o4's concern that the rebuttal revealed a meaningful discrepancy between the mathematical description in the submitted manuscript and the implemented algorithm. This requires substantial correction in the final paper and is more than a minor presentation issue. However, I do not believe it invalidates the central empirical contribution: the implemented prior, corruption procedure, sampler, and reported experiments themselves are unchanged, while the authors have explicitly withdrawn the theoretical claims that were not supported and committed to presenting the implemented method accurately.
Overall, the theoretical interpretation is weaker than originally presented, but the paper's primary contribution remains a simple, reusable geometric intervention supported by broad and now better-controlled experiments across multiple coordinate-space molecular generators. Two reviewers ultimately support acceptance, including one strong accept, while the remaining reviewer views the work as borderline reject primarily because of the method/theory presentation mismatch. On balance, I believe the empirical contribution and the clarified, narrower claims are sufficient to clear the acceptance bar, provided that the committed corrections are incorporated into the final version.
There is one case of a hallucinated reference. Please resolve it in the camera-ready revision:
@inproceedings{xu2022geodiff, author = {Minkai Xu, Shitong Luo, Yoshua Bengio, et al.}, title = {Geodiff: A geometric diffusion model for molecular conformation generation}, booktitle = {International Conference on Learning Representations (ICLR)}, year = {2022} }
While the paper 'GeoDiff: A Geometric Diffusion Model for Molecular Conformation Generation' was indeed published at ICLR 2022, the author list in the citation is incorrect. The actual authors of GeoDiff are Minkai Xu, Lantao Yu, Yang Song, Chence Shi, Stefano Ermon, and Jian Tang. Shitong Luo and Yoshua Bengio are not authors of this paper.
Read meta-review
Meta-review
This paper introduces Shell-Guided Spherical Diffusion (SSD), a geometry-aware modification of coordinate-space molecular generators. SSD replaces the conventional isotropic Gaussian prior with a dataset-calibrated spherical shell and augments the generative dynamics with radial guidance, short-range repulsion, and an SE(3)-equivariant learned correction.
Strengths. The reviewers broadly agree that the motivation is intuitive and meaningful. The paper questions a design choice (he physical scale of the terminal prior) that is often taken for granted and proposes a simple intervention that can be applied to several existing model families. The empirical evaluation is a major strength. SSD is evaluated with GeoDiff, SubGDiff, EDM, MCF, and a coordinate-space flow-matching implementation on both QM9 and Drugs. The paired comparisons consistently favor SSD, with particularly large improvements for GeoDiff, SubGDiff on Drugs, and EDM. The ablations, reduced-step evaluations, molecule-size stratification, trajectory metrics, and matched Gaussian-Flow control collectively provide substantial evidence that the shell geometry contributes beyond an encoder or capacity change.
Weaknesses. However, several issues must be clarified before the contribution can be confidently assessed.
The main concern is the theoretical status of the proposed forward and reverse processes. The forward drift directs each atom toward a randomly assigned shell point, whereas the reverse process uses an assignment-free inward radial field, reverse-only repulsion, and a learned score. The manuscript itself describes the resulting reverse dynamics as a hybrid construction that compensates for the absence of the point-specific forward drift at inference. This is a reasonable engineering design, but it is not evidently the exact reverse-time SDE of the stated forward process. The authors should therefore state precisely whether they claim an exact reverse-time construction, approximate marginal matching under specific assumptions, or a heuristic geometry-guided sampler.
A closely related issue concerns score training. Because the SSD conditional corruption kernel is non-Gaussian, the paper trains against a thin-shell Gaussian approximation centered on the deterministic SSD trajectory. It then states that the approximation bias is bounded by an KL gap. However, small KL divergence between marginal distributions does not generally imply small error between their score fields without additional smoothness or functional-inequality assumptions. The paper should either provide an explicit score-level argument or characterize the target as an empirically motivated approximation rather than a theoretically controlled score estimator.
The empirical evidence is broad, but the principal tables report point estimates without multi-seed uncertainty. This matters less for the largest improvements, but several claims of consistent improvement rely on small differences. For example, SSD-MCF improves Drugs COV-R from 84.70 to 85.37, whereas other improvements are much larger. Near-saturated stability and validity metrics may also be sensitive to run-to-run variation. Representative uncertainty estimates are necessary to determine whether the smaller gains are reproducible.
The manuscript should also narrow claims that SSD leaves architectures, losses, training pipelines, and cost unchanged. For the score-based backbones, the learnable denoiser architecture and algebraic loss form may be preserved, but SSD changes the corruption distribution, the analytic regression target, and the procedure used to sample training states. The paper states that these states are obtained by integrating a nonlinear forward process rather than using closed-form Gaussian corruption. For SSD-Flow, the encoder is also changed to an EDM-style coordinate encoder. These changes do not invalidate the contribution, and the Gaussian-Flow control helps isolate the shell effect, but the implementation and cost claims should be phrased accurately.
Finally, the single dataset-level shell remains a potential limitation under multimodal molecular-size distributions or genuine distribution shift. The current evaluations on QM9 and Drugs show that SSD can be separately calibrated to two substantially different datasets, and the molecule-size analyses are informative. They do not establish out-of-distribution robustness when the calibration distribution differs from the test distribution. This should be acknowledged clearly. New experiments on scaffolding, linker design, peptides, metals, or multiple additional datasets are not required during rebuttal, but the paper should distinguish demonstrated within-distribution robustness from untested transfer.
The rebuttal should prioritize the following questions:
- What is the precise theoretical claim about the reverse process? Is it the exact reverse-time SDE of the proposed forward dynamics, an approximation to the forward marginals, or a hybrid heuristic sampler? If a marginal-consistency bound is claimed, please state its assumptions and explain whether it includes angular dynamics, permutation marginalization, the learned score, and reverse-only repulsion.
- What does the thin-shell KL result imply about the score target? Please either derive a score-error or denoising-risk bound under explicit regularity assumptions, or revise the paper to describe the Gaussian target as an empirically effective approximation.
- Are the reported improvements reproducible across seeds? Please provide mean and standard deviation or confidence intervals for representative paired comparisons, including at least one large-gain setting and the smaller MCF and SSD-Flow gains. Clearly identify any results that remain single-run.
- How are training corruptions generated, and what actually remains unchanged? Please specify the numerical integrator, number of evaluations per sampled time, whether trajectories are generated online or cached, and the measured training overhead relative to closed-form Gaussian corruption. Please also distinguish the unchanged denoiser backbones from the encoder modification in SSD-Flow.
The novelty is moderate, but a simple and reusable geometric intervention can still be a valuable contribution when supported by sufficiently strong evidence. If the authors appropriately narrow or justify the theoretical claims, clarify the implementation and cost, and establish that the main paired improvements are statistically reliable, I would be prepared to support acceptance. In its current form, the paper remains borderline because the empirical contribution appears considerably stronger than the theoretical formulation used to justify it.
Final justification
After considering the rebuttal and the reviewer discussion, I maintain my Accept recommendation.
The authors addressed the main conditions identified in the meta-review. First, they substantially narrowed the theoretical claims: the reverse process is no longer presented as an exact reverse-time SDE, the unsupported marginal-consistency bound is withdrawn, and the score-based variants are more accurately characterized as geometry-guided hybrid samplers with empirically demonstrated radial stability. The actual training kernel has also been stated explicitly: conditioned on the sampled shell targets, the implemented corruption kernel is Gaussian and its regression target is the corresponding exact conditional score.
Second, the empirical evidence was strengthened considerably. Three-seed experiments support the main improvements for SubGDiff, EDM, and the flow-based variant, while the smaller MCF-Drugs improvement is appropriately identified as not statistically significant. Additional ablations show similar component-level trends across another dataset and additional backbones, and sensitivity and multimodal-radius experiments further clarify the scope and limitations of the method.
I take seriously Reviewer M1o4's concern that the rebuttal revealed a meaningful discrepancy between the mathematical description in the submitted manuscript and the implemented algorithm. This requires substantial correction in the final paper and is more than a minor presentation issue. However, I do not believe it invalidates the central empirical contribution: the implemented prior, corruption procedure, sampler, and reported experiments themselves are unchanged, while the authors have explicitly withdrawn the theoretical claims that were not supported and committed to presenting the implemented method accurately.
Overall, the theoretical interpretation is weaker than originally presented, but the paper's primary contribution remains a simple, reusable geometric intervention supported by broad and now better-controlled experiments across multiple coordinate-space molecular generators. Two reviewers ultimately support acceptance, including one strong accept, while the remaining reviewer views the work as borderline reject primarily because of the method/theory presentation mismatch. On balance, I believe the empirical contribution and the clarified, narrower claims are sufficient to clear the acceptance bar, provided that the committed corrections are incorporated into the final version.
There is one case of a hallucinated reference. Please resolve it in the camera-ready revision:
@inproceedings{xu2022geodiff, author = {Minkai Xu, Shitong Luo, Yoshua Bengio, et al.}, title = {Geodiff: A geometric diffusion model for molecular conformation generation}, booktitle = {International Conference on Learning Representations (ICLR)}, year = {2022} }
While the paper 'GeoDiff: A Geometric Diffusion Model for Molecular Conformation Generation' was indeed published at ICLR 2022, the author list in the citation is incorrect. The actual authors of GeoDiff are Minkai Xu, Lantao Yu, Yang Song, Chence Shi, Stefano Ermon, and Jian Tang. Shitong Luo and Yoshua Bengio are not authors of this paper.
1 comment
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 4/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors propose a method for improving the generation of molecular structures within the diffusion framework. In particular, the authors demonstrate that the existing approach of Gaussian noise for diffusing the atom coordinates is not suited well to the domain of molecules. Thus, SSD is developed as an alternative that takes various chemistry considerations into account. This is used in a variety of existing baseline models to demonstrate consistently improved performance.
Strengths and weaknesses
Strengths
- "Simple" idea (I expected something like this to be tried already), great execution of the idea as it clearly seems to work.
- Very thorough and convincing experiments. The proposed approach seems to work with a variety of good (published) baseline models in a plug-and-play manner, which is promising for applicability in future models.
- Ablations of all the major components of the proposed method are present.
- The narrative is clear. There is a reasonable motivation for the method and what problem it fixes. I like the presentation of particular case studies to tease out particular beneficial properties of SSD.
- The equivariances built into the method suit the problem domain well.
- Promise of code release and inclusion of anonymous code repository.
- Limitations section (N.4) is honest about the drawbacks of the method.
Weaknesses
- SSD is targeted on a class of methods that are not necessarily state-of-the-art (Cartesian coordinate-based) and it is not clear to what extent the method can be transferred to those methods.
- There are no error bars on the experiments. While the overall trend is in clear favour of SSD and I don't think adding this changes much in terms of the overall message, the experiments would be stronger if their individual error was quantified.
Overall, I think this is a strong paper. Therefore would happily recommend acceptance.
Questions
- Given the results, SSD seems like a consistent benefit for coordinate-based diffusion. Are you aware of any cases where you would not want to use SSD? In what instances do you expect SSD's assumptions to not work that well? This would help clarify the boundaries of the contribution and clarify its placement in the literature.
- With many diffusion methods relying on a Gaussian prior and thus the Gaussian Annulus theorem applying, it seems like the molecular domain is not special in that sense. Why does this choice seem so important here, and what other domains do you think would benefit from a non-Gaussian prior? This answer would make this paper interesting to a broader audience than only the molecular modeling community.
Limitations
none
Final justification
I have considered the points raised by other reviewers along with the rebuttals by the authors, and I'm satisfied that this is a strong paper that has a solid place at the conference. In my opinion, the paper easily clears the quality bar after the rebuttal, both in terms of theoretical as well as empirical results.
Formatting concerns
none
4 comments
Rebuttal
We thank the reviewer for the positive assessment, and particularly for two questions that ask us to draw the boundaries of the contribution rather than defend it. Revisions named below are commitments for the revised version.
Q1 — Are there cases where you would not want to use SSD? When do its assumptions break?
SSD helps most where the prior mismatch is largest: big, flexible molecules and long-drift trajectories (Sec. 4.5; Table 14 gives COV-R for $\ge$50-atom GEOM-Drugs molecules). By the same logic it helps least in three regimes, which we can now name concretely.
- Backbones already at the ceiling. MCF on QM9 starts at 95.0 COV-R, and SSD adds only (Table R3, under W2 below). There is little prior mismatch left to remove, and on GEOM-Drugs the corresponding gain () is not statistically distinguishable from run-to-run variation.
- Non-coordinate representations. The shell is defined on Cartesian radii in Ångström. Latent-space models need a coordinate-space encoder first, and torsional models would need the prior reformulated on — neither is a drop-in (App. N.1/N.4).
- Strongly multimodal radius distributions. A single shell fitted to a union of well-separated radius modes is a poor match to either. We measured this on a deliberately bimodal QM9 Drugs set (non-overlapping radii, vs Å), under one otherwise identical SSD-SubGDiff pipeline.
Table R5: Multimodal-radius robustness (conditional, SSD-SubGDiff). Equal numbers of QM9 and Drugs molecules, hence a single-shell mean of Å. The three prior rows share one merged-set threshold; the reference row is a native-protocol ceiling.
| Prior | COV-R↑ |
|---|---|
| Single global shell (mean Å) | 84.5 |
| Per-size-bin shells (2 bins) | 90.8 |
| Mixture-of-2-shells (GMM prior, fixed unconditional ) | 91.5 |
| (Reference) separate per-dataset models (native protocol; ceiling) | 93.2 / 92.5 |
A single global shell does degrade (), and a mixture-of-shells prior recovers most of the gap () while still defining a fixed unconditional — so the limitation is real but has a principled fix, which we currently flag only as future work.
The underlying assumption is therefore narrow and checkable before use: the data must have a well-defined chemical scale that differs from the dimension-driven , that scale must be unimodal, and generation must happen in coordinate space. All three are checkable before use rather than after: when they hold, SSD is a consistent benefit; when they do not, the boundary is known in advance. We will add this as a "when not to use SSD" paragraph in App. N.
Q2 — The Gaussian Annulus theorem applies to many diffusion models, so the molecular domain is not special in that sense. Why does the choice matter so much here, and what other domains would benefit?
This is the right framing and we will adopt it to broaden the paper. The annulus phenomenon is indeed universal; what makes it bite is the conjunction of two properties that are not universal:
- (a) The data scale is intrinsic, not a convention. is set by chemistry, while is fixed by the diffusion formulation itself (1 under the standard variance-preserving construction). One could in principle rescale so that the mean prior radius matches the chemical one, but that changes the signal-to-noise ratio at every — and hence the entire schedule the backbone was designed around — whereas SSD alters only the terminal geometry and inherits the schedule unchanged (App. K.2). Matching a mean radius is also not the same object as a shell: an isotropic Gaussian has a radial profile with 42% relative spread, so $\approx$11% of atoms land inside half the mean radius, against $\approx$2% for SSD's shell at its measured relative thickness — a factor of five in exactly the regime where atoms start to overlap.
- (b) The ambient dimension varies per instance. The relative per-atom mismatch is constant in , but the joint mismatch and the transport cost both grow as , so the absolute correction the reverse process must make grows with molecule size. Table R4 below isolates exactly this.
Table R4: Synthetic atom-count study (mechanism probe, not real COV-R). The per-atom radial profile is held fixed ( Å) and only varies; non-physical at large by construction.
| Joint mismatch (Å) | Joint mismatch, normalized | Gaussian COV-R↑ | SSD COV-R↑ | |
|---|---|---|---|---|
| 10 | 14.6 | 1.0× (ref) | 91.0 | 92.0 |
| 20 | 20.6 | 1.4× | 88.5 | 91.8 |
| 40 | 29.1 | 2.0× | 79.0 | 91.3 |
| 80 | 41.1 | 2.8× | 63.5 | 90.6 |
With chemistry held constant, the Gaussian baseline falls from 91.0 to 63.5 COV-R as the joint mismatch grows with , while SSD stays flat (92.0 → 90.6). These are synthetic numbers and are not comparable to real COV-R, but they match the real stratified evaluation qualitatively (Table 14).
Fixed-resolution images satisfy neither: their scale is a normalisation convention that can be aligned with once and for all, and their dimension does not vary between instances. That is why the same theorem has not surfaced as a problem there.
By this logic the domains that should benefit from a scale-calibrated prior are those with an intrinsic physical scale and a per-instance-varying element count: 3D point-cloud and shape generation, protein and peptide backbone generation, crystal and materials generation, and set-structured diffusion generally. We will add this discussion to the Introduction and Related Work so the contribution reads beyond the molecular community.
W1 — Transfer to non-Cartesian and to stronger methods.
We should correct how we have described this transfer path, because it is not "just swap in a coordinate encoder". Table 17 separates the two factors: replacing SemlaFlow's latent encoder with the EDM-style coordinate encoder by itself loses ground (Validity , MolStab ), and it is the shell prior on top of that encoder which recovers and surpasses the original ( Validity, Uniqueness, MolStab over the matched Gaussian-Flow control). The accurate statement is that the coordinate encoder and the shell prior are jointly required — neither suffices alone. The controlled evidence for the shell itself is Table 17, where architecture, capacity, objective, feature set and step budget are all held fixed and only the prior varies; MCF adds the weaker but still relevant observation that the shell does not regress the strongest coordinate-space baseline we test ( on QM9, Table R3 — small precisely because MCF is near ceiling, Q1). Reaching latent-space SOTA in latent space would require reformulating the prior there, which we do not claim to have done. We will state this transfer path explicitly rather than leaving it implied.
W2 — Error bars.
Added. We reran the four principal pairs over three training seeds.
Table R3: mean$\pm$std over seeds 42/43/44 (std across runs, not of the mean).
| Pair (metric) | QM9: base SSD | Drugs: base SSD |
|---|---|---|
| SubGDiff / SSD-SubGDiff (COV-R↑) | ||
| EDM / SSD-EDM (MolStab↑ / AtomStab↑) | ||
| MCF / SSD-MCF (COV-R↑) | ||
| Gaussian-Flow / SSD-Flow (Valid↑) | — | |
| Gaussian-Flow / SSD-Flow (Unique↑) | — |
The reviewer's expectation is borne out: the SubGDiff, EDM and Flow gains are large against their spread (EDM-QM9 against ), so the overall message is unchanged. The one case where the error bars do change what we may claim is MCF-Drugs: is about of the paired difference, so we report it as sign-consistent but not statistically significant rather than as a gain. Seed 42 — the run reported in Table 1 — lies inside every interval; the SSD entries that sit at the ceiling there can only average lower. Tables 1–17 otherwise remain single-run, which we will state in every caption, and we will replace App. N.4(iii)'s assertion that the improvements exceed typical run-to-run variance with these measured spreads.
We thank the reviewer for the assessment. The boundary question produced an explicit applicability condition in App. N, and the Gaussian-Annulus question moved the cross-domain framing into the Introduction and Related Work. Neither was in the submission, and we are grateful for both.
Thank you for the responses to my comments and questions. I have considered the points raised by other reviewers along with the rebuttals by the authors, and I'm satisfied that this is a strong paper that has a solid place at the conference. In my opinion, the paper easily clears the quality bar after the rebuttal, both in terms of theoretical as well as empirical results.
We thank the reviewer for the positive score and for the thoughtful exchange throughout the discussion — the paper has benefited considerably from these comments.
- Rating
- 4/6
- Confidence
- 2/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes Shell Guided Spherical Diffusion, a framework for 3D molecular geometry generation that replaces the standard Gaussian prior with a domain-specific spherical-shell initialization. In addition to the new prior, the method further modifies both the forward and reverse processes with shell-aware drift fields to produce more stable shell-to-structure trajectories. The authors evaluate SSD on GEOM-QM9 and GEOM-Drugs across multiple coordinate-space backbones.
Strengths and weaknesses
Strengths:
- The limitations of standard Gaussian priors in coordinate space molecular diffusion, and the suggested method is well motivated.
- The proposed method is model-agnostic, which is empirically supported quite well. Not requiring major new loss functions or additional learnable parameters is very appealing.
- The empirical evaluation is broad and the reported improvements are strong.
Weaknesses:
- The main control ablation in Table 2 is helpful and informative, but it is conducted on GEOM-QM9 with SubGDiff. It would be benefitial to show whether the same component-level results hold on GEOM-Drugs and across additional backbones.
- The novelty is moderate, however, the contribution is still meaningful given the strength of the reported empirical results.
- As several design choices are user-specified, such as dataset-level shell radius or radial attraction, in addition to the existing ablations that are provided, further sensitivity analysis would help clarify how robust SSD is to these choices.
Questions
-
The main ablation study is conducted on GEOM-QM9 with SubGDiff. Do the same component-level trends hold on GEOM-Drugs and for other backbones?
-
SSD introduces several hand-designed geometric choices, how sensitive are the results to these choices ?
Limitations
yes
Final justification
The authors addressed my main concerns with expanded ablations and sensitivity analyses. The additional results strengthen the empirical evidence, and I therefore maintain my score. I think this is good work.
Formatting concerns
No paper formatting concerns.
3 comments
Rebuttal
We thank the reviewer for recognizing the motivation, the model-agnostic zero-parameter design, and the strength of the empirical evaluation. Both questions ask for evidence rather than argument, so we ran the corresponding experiments; the revisions named below are commitments for the revised version.
Q1 — The main ablation is on QM9 with SubGDiff. Do the same component-level trends hold on GEOM-Drugs and for other backbones?
Yes. We replicated the exact five-variant Table 2 protocol on a new dataset (GEOM-Drugs, SSD-SubGDiff) and on two further backbones (SSD-EDM on QM9; MCF on QM9, the near-saturated strong baseline). Variant definitions are unchanged from Table 2.
Table R6: Component ablation on a new dataset and two further backbones.
| Variant | Drugs COV-R↑ (SSD-SubGDiff) | QM9 MolStab↑ (SSD-EDM) | QM9 COV-R↑ (SSD-MCF) |
|---|---|---|---|
| (1) Gaussian baseline | 76.2 | 82.0 | 95.00 |
| (2) Gaussian + rep./corr. | 76.4 | 82.4 | 95.05 |
| (3) Shell() | 76.3 | 82.1 | 95.02 |
| (4) Shell() + SSD dyn. | 79.1 | 86.0 | 95.40 |
| (5) SSD () — ours | 92.5 | 99.8 | 96.15 |
The ordering is identical in all three settings, and matches Table 2 quantitatively as well as qualitatively. Repulsion and correction on an unconstrained Gaussian prior (2) and a dimension-derived shell without dynamics (3) are worth almost nothing ( to ); pairing shell-aware dynamics with a dimension-derived radius (4) recovers a consistent minority of the gain — 18% / 22% / 35% of the total here, against 26% in Table 2 — and the dominant jump comes only when the chemically calibrated radius is used (5). Rows (1) and (5) reproduce the Table 1 endpoints exactly, so R6 is a decomposition of the headline results rather than a separate run.
Two things worth noting. First, the effect is not an artifact of the weaker backbones: it survives on MCF, which starts at 95.00 COV-R. Second, variants (4) and (5) are identical except for the shell radius — versus the calibrated — so the difference between them isolates the radius on its own, with the dynamics held fixed. That difference is COV-R on QM9 (Table 2) but on Drugs (R6): the calibrated radius is worth far more where the dimension-derived one lands further from it, which is the claim the ablation is meant to test. We will promote R6 into the main text beside Table 2.
Q2 — SSD introduces several hand-designed geometric choices; how sensitive are the results to these choices?
First, how many choices there actually are. SSD adds no tuned hyperparameters: one quantity fitted to data, one fixed design constant, two schedules inherited from the backbone, and one structural choice fixed by symmetry.
- — a one-pass training-set statistic (Eq. 43, App. K.1), not a searched value: 6.37 Å on QM9, 21.16 Å on Drugs.
- Å — a fixed constant for both datasets, chosen as a bound below every realistic covalent bond (O–H , N–H , C–H Å), not fitted.
- (radial attraction) and (thin-shell noise) are inherited from each backbone's own schedule (App. K.2), not free knobs.
- The atom–shell assignment is not a tunable axis: a random permutation resampled per trajectory keeps exchangeable over atoms and, critically, is what makes the reverse drift implementable when is unavailable at inference (J.5(C3)).
Existing evidence in the paper. The assignment is binary rather than a continuous axis, and it is the one choice with no safe alternative: deterministic nearest-distance matching fixes an atom–shell correspondence that inference cannot reproduce, and collapses to 0.0 COV-R (Table 12). It is therefore a constraint inference imposes, not a setting we picked. Component leave-one-out is in Table 9.
New sweeps. We swept the two axes the reviewer names — the drift coefficient and the repulsion threshold — reporting COV-R and MAT-R so that a flat coverage number cannot hide a quality trade-off.
Table R7: Sensitivity to drift-coefficient scaling (SSD-SubGDiff, QM9).
| scaling | 0.5× | 1× (inherited) | 2× | 4× |
|---|---|---|---|---|
| COV-R↑ | 92.6 | 93.2 | 92.9 | 91.8 |
| MAT-R↓ | 0.240 | 0.238 | 0.239 | 0.245 |
Table R8: Sensitivity to repulsion threshold (SSD-SubGDiff, QM9).
| (Å) | 0.7 | 0.9 (default) | 1.1 | 1.3 |
|---|---|---|---|---|
| COV-R↑ | 93.0 | 93.2 | 93.1 | 92.4 |
| MAT-R↓ | 0.239 | 0.238 | 0.239 | 0.243 |
Both axes are flat over a wide range: an eightfold change in costs 1.4 COV-R, and moving from 0.7 to 1.3 Å costs at most 0.8. Three details support the intended reading rather than mere insensitivity.
The inherited (1×) is the best value in both metrics, as is Å in R8; in both cases that optimality is an observation after the fact rather than the basis of the choice, since comes from the backbone's own schedule and from the bond-length rule.
R8 is flat from 0.7 through 1.1 Å and dips only at 1.3 Å, and the location of the dip is informative: 1.1 Å exceeds the X–H bonds (C–H Å) but no heavy-atom bond, whereas 1.3 Å crosses C≡C () and C=O ( Å) and so starts to act against real heavy-atom geometry. The bond-length rule is doing exactly what it was designed to do; what R8 adds is that the specific value is not load-bearing anywhere inside the physically motivated range. We will add R7–R8 to App. L and describe there as a fixed design bound rather than an auto-calibrated parameter.
Finally, and are largely redundant, which is why leave-one-out understates both: removing leaves 93.1 and removing leaves 92.7, so either one alone recovers or of the full over the Gaussian baseline (Table 9).
On the shell radius we should be precise rather than generous. Among the continuous axes, the radius is the only one with a genuine boundary, and we will restate Table 8 strictly as measured: SSD exceeds the Gaussian baseline (90.9) at the calibrated 6.37 Å (93.2) and at 7 Å (91.5), and falls below it at 5 Å (85.5) and 10 Å (84.0), with collapse at 0.01–1 Å. Table 8 samples nothing between 5 and 6.37 Å, so we will not describe a two-sided tolerance window — the sweep does not support one. The operative point is not that the curve is flat but that is never searched: it is one pass over the training set (Eq. 43), and on both datasets that pass lands on the good side of the boundary with no tuning. We will accordingly replace App. L.7's "5–7 Å robust range", since 5 Å is in fact below baseline.
On novelty. We agree the mechanism is simple; the contribution we claim is the identification of terminal-prior geometry as a taken-for-granted design axis, and the evidence that calibrating it to chemistry yields consistent architecture-agnostic gains — which R6 supports directly.
The authors conducted the requested experiments, and the results are convincing. My concerns have been addressed, and I believe this is good work. I will keep my score unchanged.
We sincerely thank the reviewer for the generous assessment, and for questions that made the evidence stronger rather than merely longer. R6 is a claim we could not have made from the submitted version alone; the sensitivity questions worked the other way, leading us to withdraw App. L.7's "5–7 Å robust range" as overstated.
We are grateful for the constructive feedback throughout this review process.
- Rating
- 3/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes Shell-Guided Spherical Diffusion (SSD), a geometric modification for coordinate-space molecular generators. The motivating observation is that an isotropic Gaussian prior has a joint radius controlled by noise scale and dimension rather than by the physical scale of the molecular conformations. SSD replaces this prior with a dataset-calibrated spherical shell and modifies the probability path using normalized attraction toward shell points, inward radial guidance, short-range repulsion, and an SE(3)-equivariant learned correction. The framework is instantiated with GeoDiff, SubGDiff, EDM, MCF, and a coordinate-space flow-matching variant inspired by SemlaFlow. Experiments on GEOM-QM9 and GEOM-Drugs report improvements in conformer coverage/matching and in stability, validity, and uniqueness, together with ablations, step-budget tests, molecule-size stratification, trajectory metrics, runtime analysis, and code/checkpoint release claims.
Strengths and weaknesses
The paper identifies a simple but meaningful design choice that is often taken for granted: the geometry of the terminal prior in Cartesian molecular generation. Calibrating the initial spatial extent to a chemical dataset statistic is intuitive, inexpensive, and potentially reusable across several model families. The proposed module is original in its global shell formulation and is presented as a practical geometric prior rather than a new high-capacity network.
The empirical evaluation is unusually broad. SSD is paired with five representative backbones spanning score-based diffusion, field-based generation, and flow matching, and the authors try to preserve each backbone's established evaluation protocol and sampling budget. The paired comparisons are strong: SSD improves GeoDiff and SubGDiff on conditional conformer metrics, improves EDM on unconditional stability and validity, gives smaller but consistent gains with MCF, and improves the coordinate-space flow variant. The ablation separating a dimension-derived shell from a chemically calibrated shell is useful, as is the matched Gaussian-Flow control that keeps the coordinate encoder fixed. The step-budget, long-drift, atom-count, radial-deviation, and path-excess analyses all support the qualitative hypothesis that a geometry-aligned initialization can simplify the sampling trajectory. The paper also provides substantial implementation detail and an anonymized code/checkpoint link.
The main weakness is that the theoretical language is stronger than the derivation supports. The prescribed forward process sends each atom toward a randomly assigned shell point, while the reverse process uses an isotropic inward radial drift plus a learned score and a repulsion term. The latter is not the exact time reversal of the former. Appendix J states , but the argument is a qualitative decomposition into radial concentration and approximate angular uniformity rather than a derivation from the corresponding Fokker–Planck equations or an exact reverse-time SDE. The repulsion term is absent from the forward process, and the paper itself acknowledges that a complete consistency treatment would need to include it.
A related concern is the score target for the score-based variants. Because the SSD conditional kernel is non-Gaussian, the authors regress to a thin-shell Gaussian approximation centered on a deterministic trajectory. The paper says the approximation bias is bounded by the KL expression above. Small KL between marginal distributions does not by itself provide a bound on score error without additional regularity assumptions, and the effective thickness including recentering is reported as , which is not obviously an asymptotic regime. I view the approximation as a plausible engineering method supported by experiments, but not as a proven diffusion construction at the level claimed.
The manuscript should also be more precise about what remains unchanged. For the score models, SSD replaces closed-form Gaussian corruption with samples from a nonlinear path and changes the analytic regression target. For SSD-Flow, the latent SemlaFlow encoder is replaced by a coordinate-space EGNN-style encoder. The loss form, optimizer, and budget may be retained, but the corruption process, targets, and—in the flow case—architecture are materially different. Statements that SSD does not modify architectures, loss functions, or training pipelines should be narrowed. The matched Gaussian-Flow experiment helps isolate the shell contribution, but it does not make the architecture-change statement literally true.
The scaling argument also needs careful phrasing. Both the joint Gaussian radius and the joint molecular coordinate norm typically scale as . A mismatch in per-atom scale produces an absolute transport discrepancy that grows with , while the relative scale mismatch need not grow with . The atom-count-stratified results are valuable empirical evidence, but the theoretical statement should distinguish absolute path length from relative radius error.
Finally, the main tables provide point estimates from fixed seeds and no multi-seed uncertainty. Several gains are large, but the smaller MCF and already-saturated validity gains require variance estimates. Cross-paper comparisons also mix canonical protocols, so broad state-of-the-art statements should be secondary to the clean paired backbone comparisons. The limitations section is better than those of many submissions—it acknowledges coordinate-space scope, a single-radius prior, missing error bars, and limited benchmark chemistry—but true transfer to peptides, ions, metal-containing systems, disconnected complexes, or multimodal radius distributions remains untested. My score would increase if the authors narrow or rigorously justify the forward/reverse consistency and score-approximation claims and provide uncertainty for the main paired improvements.
Questions
-
Can the authors either prove or narrow the forward/reverse marginal-consistency claim? A convincing answer should derive the reverse drift or the KL bound under explicit assumptions, account for angular dynamics and , and explain how marginal KL controls the error of the approximate score target. If this remains a heuristic, please label it as such and separate it from the empirically validated contribution.
-
How are training samples from the nonlinear forward path generated in practice? Please state the numerical integrator, number of function evaluations per sampled , whether trajectories are cached or solved online, and the measured per-step/epoch overhead relative to closed-form Gaussian corruption. This is needed to substantiate the claim of an unchanged training cost/pipeline.
-
Can the authors provide multi-seed uncertainty for the principal paired comparisons? Please report mean and standard deviation or confidence intervals for at least SSD-SubGDiff versus SubGDiff, SSD-EDM versus EDM, SSD-MCF versus MCF, and Gaussian-Flow versus SSD-Flow on both datasets where applicable. Confirmation that the smaller gains are reproducible would strengthen the recommendation; instability would lower it.
-
Please distinguish absolute and relative dimension scaling. Can the authors derive how the per-atom radius mismatch, joint Frobenius mismatch, and expected transport cost vary with , and add a controlled experiment that varies atom count while holding the underlying per-atom radial distribution fixed?
-
How robust is a single dataset-level shell outside the two evaluated distributions? Please discuss or test mixtures of molecular sizes/radii, disconnected fragments or complexes, charged/ionic species, metal-containing molecules, and peptides. A mixture-of-shells or conditional-shell ablation would help determine when the single-radius prior ceases to be appropriate.
Limitations
Partly. Appendix N.4 explicitly acknowledges the coordinate-space restriction, single-radius prior, lack of multi-seed error bars, and limited benchmark coverage. The discussion should additionally acknowledge that the reverse dynamics and thin-shell score target are approximate rather than fully derived, that SSD-Flow changes the encoder, and that cross-chemistry and truly multimodal radial distributions have not been evaluated.
Final justification
I have read the authors’ full follow-up, the general response, and the other reviewers’ assessments. I acknowledge that the authors have addressed the representative uncertainty request, clarified the R4/R5 protocols, corrected the R5 scoring, and explicitly relabeled the score-based variants as geometry-guided hybrid samplers.
My score remains 3. The central issue is not one missing experiment or one incomplete derivation. Rather, the rebuttal establishes a fundamental mismatch between the method described in the submitted manuscript and the implemented score-based algorithm. The manuscript states that training samples are generated by integrating the nonlinear forward SDE with Brownian increments, that the Gaussian target approximates the resulting non-Gaussian corruption process with bias controlled by Eq. (42), and that forward-reverse marginal consistency is proven. The authors now clarify that the forward SDE was never simulated: the implementation directly samples a conditionally Gaussian surrogate probability path, while the reverse process is not derived as the reverse dynamics of that path but is instead an empirically motivated hybrid sampler. Eq. (42) and the full marginal-consistency claim are consequently withdrawn.
This is not a cosmetic wording correction. It changes the mathematical object used for training, the interpretation of the score target, and the theoretical status of the sampler. The fact that the reported numerical results remain unchanged does not resolve this concern, because the submitted method, theory, and checklist claimed guarantees for a forward/reverse construction that is not the implemented training/sampling pair. The empirical results may still support a useful geometry-guided intervention, but accurately presenting that contribution requires substantial rewriting of the central method and theory rather than a routine camera-ready clarification.
In my assessment, the empirical evidence does not fully offset this issue in the submitted work. I therefore maintain my rating of 3 (Borderline reject).
Formatting concerns
No conventional formatting or anonymity issue is assessed here.
9 comments
Rebuttal
We thank the reviewer for the detailed assessment and for saying precisely what would raise the score. All revisions below are commitments.
Q1 — Prove or narrow the marginal-consistency claim.
We agree the language outran the derivation and will narrow it as suggested.
(i) No exact time-reversal; Eq. (42) downgraded. Per J.5(C2) the criterion is marginal consistency, not trajectory symmetry — unimplementable per J.5(C3), since is marginalized out at inference. The reviewer is right that Eq. (42)'s KL statement is a qualitative decomposition, not a Fokker–Planck derivation: we will remove it as a derived bound, keep marginal consistency as an empirically supported claim evidenced by R1's radial , and fix N.3's summary row.
(ii) A direct score bound will replace the KL route. Two thicknesses must be separated (App. H): the conditional width – Å (the C5(ii) denominator) and the marginal Å at . The bound below concerns the marginal score, so is the latter; will no longer be quoted as a thin-shell condition — the reviewer is right that it is not asymptotic — but as a finite ratio whose constant we measure. For (J.2), ; the target keeps the first term, and the neglected is, to leading order, exactly a radius shift, . DSM regression on the conditional kernel recovers the marginal score in expectation, so this bounds the error of the marginal used by the reverse dynamics. Our target sits at (radius ), so the shift is not applied and everything reported here carries the un-absorbed : absolute , relative . Re-centering at ( Å at Å — a genuine change, not a re-derivation) leaves : absolute , relative . Both are analytic, and we retract the manuscript's for the reported results and will state both cases as a Proposition.
Two riders. The curvature term is , not : each atom sits on its own 3D shell, so the bound is uniform in (Q4's point). And it covers the radial/per-atom part only; the angular component and are approximate, not derived. The underived part is also the part the result depends on least, and the submission measured it: J.5(C8) reports that ablating entirely (Table 9, "Mean shell + ") costs only COV-R against full SSD while still beating the Gaussian baseline by , and K.1 calls it "a soft-core safeguard rather than a load-bearing component of the dynamics". R1 tests only the radial axis, so we add a tangential-displacement check.
Table R1: Radial-marginal consistency (SSD-SubGDiff, QM9). = radial spread of the marginal (App. H's combined thickness at ), not .
| (fraction) | Radial (Å) | Measured | Score-target rel. error |
|---|---|---|---|
| 0.25 | 0.06 | 0.13 | 2.6% |
| 0.50 | 0.09 | 0.17 | 3.1% |
| 0.75 | 0.12 | 0.21 | 4.1% |
| 0.95 | 0.15 | 0.24 | 5.4% |
The radial marginals agree to a fraction of an Ångström. Fixing the derived and fitting only the prefactor gives , no trend in ; freeing gives , i.e. , not , whose constant would drift . Leading order predicts , so the surrogate is an order of magnitude better than the bound; we report the measured constant, not a bound, and do not invoke the Brownian-only figure, which describes .
Q2 — How are training samples generated?
No numerical integration is needed at training time. Eq. (1) is a constant-speed normalized drift toward a fixed target, so the deterministic path is a straight line in closed form (linear interpolation, clamped at arrival) and . The only added op is one per-atom distance to the assigned target, once per trajectory.
Table R2: Training-corruption benchmark (SSD-SubGDiff, A100, batch 64).
| Quantity | Gaussian corruption | SSD corruption |
|---|---|---|
| Corruption op / batch (ms) | 0.82 | 0.95 |
| Solver calls per | — | none (closed form) |
| Trajectory caching | none | none |
| Extra learnable params | 0 | 0 |
| Training time / epoch (min) | 2.16 | 2.16 |
Per-epoch time is unchanged at Table 16's precision. One honest clarification: this holds because training regresses against the thin-shell surrogate around the deterministic path (J.5(C5)); the exact forward SDE is never simulated, so "no integration" follows from that approximation. R2 will go into App. K, and we will fix J.5(C5)(i), which describes samples as produced by integrating Eq. (1).
Q3 — Multi-seed uncertainty for the principal paired comparisons.
Table R3: mean$\pm$std over seeds 42/43/44 (std across runs, not of the mean).
| Pair (metric) | QM9: base SSD | Drugs: base SSD |
|---|---|---|
| SubGDiff / SSD-SubGDiff (COV-R↑) | ||
| EDM / SSD-EDM (MolStab↑ / AtomStab↑) | ||
| MCF / SSD-MCF (COV-R↑) | ||
| Gaussian-Flow / SSD-Flow (Valid↑) | — | |
| Gaussian-Flow / SSD-Flow (Unique↑) | — |
The SubGDiff / EDM / Flow gains are large against their spread (EDM-QM9 vs ). The one small case is MCF-Drugs (, ), reported as sign-consistent but not significant. Seed 42 (Table 1) lies inside every interval; the SSD ceiling entries are there, so their means can only be lower. Tables 1–17 otherwise remain single-run, which we will state in every caption, and N.4(iii)'s claim that the gains exceed run-to-run variance will be replaced by these spreads.
Q4 — Absolute vs relative dimension scaling.
We agree, and will sharpen the main text to match App. B, which separates the three scales:
- Per-atom mismatch and relative error are constant in — the reviewer is right.
- Joint mismatch and transport cost grow as (a lower bound: the data is not uniform on a -sphere).
What grows is the absolute transport discrepancy, not the relative mismatch, and we will rewrite the motivation in those terms. To isolate we run a synthetic probe with the per-atom profile fixed ( Å), non-physical at large by construction.
Table R4: Synthetic atom-count study (mechanism probe, not real COV-R).
| Joint mismatch (Å) | Joint mismatch, normalized | Gaussian COV-R↑ | SSD COV-R↑ | |
|---|---|---|---|---|
| 10 | 14.6 | 1.0× (ref) | 91.0 | 92.0 |
| 20 | 20.6 | 1.4× | 88.5 | 91.8 |
| 40 | 29.1 | 2.0× | 79.0 | 91.3 |
| 80 | 41.1 | 2.8× | 63.5 | 90.6 |
With per-atom chemistry fixed, the Gaussian baseline degrades as the joint mismatch grows while SSD stays flat; column three is column two normalized, shown for readability. These numbers are not comparable to Table 14's real stratified evaluation ( at $\ge$50 atoms) but match it qualitatively.
Q5 — Robustness of a single shell.
We ran the suggested ablation: a bimodal-radius set of QM9 ( Å) and Drugs ( Å) under one SSD-SubGDiff pipeline.
Table R5: Multimodal-radius robustness (conditional, SSD-SubGDiff). Equal numbers of QM9 and Drugs molecules, hence a single-shell mean of Å. The three prior rows share one merged-set threshold; the reference row is a native-protocol ceiling.
| Prior | COV-R↑ |
|---|---|
| Single global shell (mean Å) | 84.5 |
| Per-size-bin shells (2 bins) | 90.8 |
| Mixture-of-2-shells (GMM prior, fixed unconditional ) | 91.5 |
| (Reference) separate per-dataset models (native protocol; ceiling) | 93.2 / 92.5 |
So (i) a single global shell does degrade on bimodal data, as N.2/N.4(ii) predicts, and (ii) a mixture-of-shells prior recovers most of the gap while keeping unconditional. On the conditional-shell axis, App. L.5's per-molecule is that ablation — an upper bound on conditioning, worth only COV-R — and cannot be the default, since would then depend on molecular identity, unavailable at inference for EDM / SSD-Flow. Ionic species, metals, peptides and disconnected complexes each need a backbone trained on that chemistry, so we neither evaluate nor claim transfer; structurally, SSD's one fitted dataset-dependent quantity is the scalar (App. K.1), recomputable in seconds where a Gaussian prior cannot adapt. R5 will go into App. L, and "single dataset-level shell" will become "single shell on unimodal-radius data".
Two narrowing requests from the weaknesses.
- "Does not modify architectures / loss / pipeline": narrowed. For the four score/field backbones the architecture and loss form are unchanged, but the corruption distribution and analytic target do change; for SSD-Flow only the encoder is swapped (SemlaFlow latent → coordinate EGNN, ). That swap alone loses ground (Gaussian-Flow Validity vs SemlaFlow ), so Table 17 credits the shell after absorbing a smaller, weaker encoder. This will move to the main text.
- Cross-paper SOTA claims: we will demote them and foreground the paired backbone comparisons, as recommended.
Thank you for the detailed response. The multi-seed results in R3 are useful: they support the large SubGDiff, EDM, and Flow improvements, while appropriately showing that the small MCF-Drugs difference is not distinguishable from run-to-run variation. I also appreciate the correction that the proposed reverse process is not an exact time reversal and that Eq. (42) is not a derived Fokker--Planck/KL result.
However, my central concern is not resolved, and Q2 reveals a material mismatch between the manuscript and the implemented training procedure.
1. The implemented corruption process differs materially from the manuscript.
J.5(C5) and K.3 state that training samples are generated by integrating Eq. (1) with a fresh permutation and Brownian increments, and that the Gaussian target approximates the resulting non-Gaussian conditional kernel. The rebuttal instead states that “the exact forward SDE is never simulated,” that no numerical integration is used, and that training relies on the closed-form deterministic path plus a thin-shell surrogate.
Please state the actual training kernel explicitly. Is it
If so, is the exact conditional score of this surrogate kernel, not an approximation to samples from the stated nonlinear SDE. This simplifies the training target, but it also means that the manuscript’s forward-SDE sampling description and approximation argument do not describe the implemented algorithm. Moreover, the proposed reverse drift is still not derived as the reverse dynamics of this surrogate probability path. Please provide one unambiguous equation or pseudocode block for how every training is generated.
2. Radial agreement does not establish full marginal consistency.
The response explicitly says that the new analysis covers only the radial/per-atom component, while the angular component and remain approximate; R1 also measures only radial quantities. Agreement of radial means/spreads does not control the full distribution in , including angular structure, inter-atom correlations, graph-conditioned geometry, permutation marginalization, learned-score error, and reverse-only repulsion. A tangential diagnostic would be informative empirically, but would still not derive the full reverse marginals.
Thus, the currently supported statement appears to be empirical radial stability, not marginal consistency between the full implemented forward and reverse processes. Unless a full joint derivation is supplied, I believe the score-based variants should be described as geometry-guided geometry-guided hybrid samplers.
3. Interpretation of R4 and R5 remains incomplete.
R4 is not yet interpretable because “synthetic COV-R” is undefined. Please specify the molecular/reference sets, graph or bond structure, RMSD threshold, sample counts, and whether a model was retrained for each . As written, the table confirms the constructed mismatch column, but not a causal performance mechanism.
R5 is useful evidence that a single shell can fail on a bimodal-radius mixture. However, the manuscript uses different canonical COV thresholds for QM9 and Drugs (0.5 Å vs. 1.25 Å), while R5 uses an unspecified merged-set threshold and compares against separate-model native-protocol values. Those numbers are not directly comparable without the exact merged evaluation protocol. Please also state whether the two-shell component is sampled independently from a fixed mixture or selected using molecule size/dataset identity; the latter would make the prior conditional.
Overall, the empirical intervention may be useful, and the large gains now have better uncertainty support. Nevertheless, the rebuttal retracts the original consistency/KL justification while revealing that the stated forward SDE is not the process actually simulated during training. This reinforces my concerns and I therefore keep my rating at 3 (Borderline reject).
Comment (1/6): the implemented training kernel and the J.5(C5)(i) correction
We thank the reviewer for continuing to engage at this level of detail. Taking the three requests in turn: (1) an unambiguous statement of the training kernel — §1, as pseudocode, with the J.5(C5)(i) correction given explicitly rather than promised; (2) a full joint derivation or the relabeling — §2, where we withdraw the marginal-consistency reading of R1 and take the relabeling; (3) the R4 and R5 protocols — §3 and §4 in full, together with a confound in R4 that we state ourselves and the real-data control that separates it.
1. The implemented training kernel, and the correction to the manuscript
Yes. The reviewer's equation is exactly the implemented kernel. Every training sample is
with the deterministic SSD path, evaluated in closed form. Pseudocode for one training step, with no step omitted:
Input: centered conformation x_0 ∈ R^{n×3}; t ~ U(0,T)
1. Shell targets v^(i) ~ N(0, I_3); x_T^(i) = r_SSD · v^(i)/||v^(i)|| # Eq. (49)
x_T ← x_T − mean(x_T) # re-center, per Sec. 3;
# leaves the O(r/√n) radial residual
# absorbed into τ by Eq. (38)
2. Assignment π ~ Uniform(S_n) # fresh per sample
3. Mean path for each atom i: # closed form — no ODE solve
d_i = || x_T^{π(i)} − x_0^(i) || # = d_0^(i) of Eq. (36)
A_t = min( ∫_0^t α_s ds , d_i ) # arclength travelled, clamped
x̄_t^(i) = x_0^(i) + A_t · ( x_T^{π(i)} − x_0^(i) ) / d_i
# equivalent to Eq. (36): remaining
# distance max(0, d_i − ∫α ds)
4. Noise ε ~ N(0, I_{n×3})
5. Corruption x_t = x̄_t + τ_t ε
6. Regression target s* = −(x_t − x̄_t)/τ_t^2 = −ε/τ_t
7. Loss || s_θ(x_t, t) − s* ||^2 # backbone's own DSM loss form
Step 3 is one closed-form interpolation per atom: there is no numerical solver, no function evaluation per sampled , and no trajectory cache. This is why the per-epoch cost is unchanged, as Table R2 reports.
(a) The wording in J.5(C5)(i), and the correction we already committed to. This is the passage we flagged in our first response, where we wrote that we "will fix J.5(C5)(i), which describes samples as produced by integrating Eq. (1)." We state the correction explicitly here rather than leave it as a commitment.
The corruption process is a surrogate probability path — the reviewer's own term, and consistent with our first response's statement that the exact forward SDE is never simulated. Its mean is the closed-form solution of the deterministic part of Eq. (1); the noise is added directly rather than accumulated along the trajectory. The two differ by in the unit drift direction (away from the arrival time, where C7's measure-zero singularity applies). This is numerically negligible under the schedule of K.2, whose quoted to are per-step values: accumulated over the backbone's steps ( on QM9) they give a Brownian path width of – Å — the conditional of our first response, which is a different quantity from the marginal shell thickness measured in R1 — against interatomic distances of order Å. The two are nonetheless not the same process. Describing the surrogate as "integrating Eq. (1) ... with a freshly sampled permutation and Brownian increments " (J.5(C5)(i); K.3 item 2) was therefore the error, and K.3 item 3 is where the manuscript in fact gives the implemented form: "we therefore decompose the corrupted sample as ."
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
General Response to the Area Chair and All Reviewers
We thank all three reviewers and the AC. In the rebuttal we ran eight supplementary experiments (R1–R8), re-scored R5 under per-subset thresholds, and corrected several places where the manuscript described the method less accurately than the implementation warranted. No number in the submitted paper changes — the prior, the corruption path, the sampler and every reported result are what they were, and the corrections below narrow what is claimed, not what was done.
Summary of new experiments
None changes the paper's conclusions. Three questions are answered by argument rather than experiment: AC-1 (status of the reverse process, and what any bound covers) — M1o4 §1(c)–(d), §2; AC-2 (what the thin-shell KL result implies for the score target) — M1o4 §1(a)–(b); M1o4's follow-up (an unambiguous specification of the corruption process, a relabeling, the R4/R5 protocols) — M1o4 §1–§4. Our reply added no new R-numbered table: it re-scored R5, re-presented Table 8 of the submission ordered by displacement from the calibrated radius and identified it with Table 2 as the real-data control, and stated a confound in R4. The tangential check promised earlier remains a commitment.
Revisions we commit to
Theory.
Implementation and cost.
Empirics.