potentialpaper

SOAR: Semantic Organ-Aware Pretraining for 3D CT Image Understanding

Huidong Xie, Wei Ji, Sunan He, Zhihao Tang, tangwen, Jun Zhao, Hongming Shan

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. SOAR improves 3D CT image understanding through report-free, organ-aware pretraining that learns anatomical structures and semantics to better answer medical questions and detect diseases.

Abstract. Vision-language pretraining has advanced multimodal medical AI, but its direct application to 3D computed tomography (CT) remains limited by a fundamental mismatch between dense volumetric anatomy and sparse diagnostic reports. Existing 3D CT vision-language methods typically rely on global image-report alignment or align anatomical regions with decomposed report descriptions. However, a CT scan captures rich, spatially distributed information across many organs, whereas a report summarizes only a small subset of clinically relevant findings. As a result, report-based alignment provides incomplete or weak supervision, leaving many local anatomical structures underrepresented. Motivated by this limitation, we introduce SOAR, a semantic organ-aware pretraining framework for 3D CT image understanding. The key innovation of SOAR lies in its integration of fine-grained, organ-level structural priors, enabling report-free organ-aware supervision for visual pretraining without relying on radiologist annotations or coarse global image-report matching. SOAR combines three complementary objectives: (i) organ-level masked reconstruction to learn localized anatomical context, (ii) organ-level vision-language alignment to associate organ-specific visual features with organ-name text embeddings, and (iii) organ-level supervision to preserve voxel-level structural detail. SOAR integrates easily with existing LLMs and is evaluated on five public/in-house benchmarks, improving multiple-choice VQA accuracy by 3.53 percentage points and disease screening/abnormality detection AUC by 4.25 points on average over all benchmarks/baseline methods. Code and model weights are available at https://github.com/HuidongXie/SOAR_CT.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
3 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)forumreviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:50 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The proposal of SOAR—to inject organ-level anatomical priors into 3D CT visual representation learning—and its core motivation of alleviating the semantic mismatch between sparse diagnostic-report supervision and dense 3D CT anatomical information, received unanimous recognition from the three reviewers. However, the reviewers' scores diverged significantly (4: Borderline Accept, 5: Accept, 2: Reject), reflecting deep-seated disagreements over the paper's technical rigor and experimental completeness. One reviewer explicitly pointed out that SOAR should not be categorized as a self-supervised method, since it relies on pseudo-labels generated by TotalSegmentator as supervisory signals, which is fundamentally different from truly self-supervised pre-training approaches such as MAE. Therefore, the authors must supplement fair comparisons with supervised pre-training baselines (e.g., MedVAE, Foundation VAEs, pre-trained segmentation model encoders); otherwise, the baseline selection suffers from serious unfairness. In addition, two reviewers jointly noted critical omissions in the ablation study: the paper does not perform independent on/off ablations for each loss component, making it impossible to assess the necessity and individual contribution of each component. Moreover, a comparison between PubMedBERT embeddings and simple fixed class tokens is missing, which is essential to support the claimed technical contribution of "organ-level visual-language alignment." Regarding the evaluation scope, two reviewers pointed out that the current qualitative examples are overly focused on the lungs, the pre-training data is limited to non-contrast chest CTs, and fine-grained downstream tasks such as segmentation and detection are absent—all of which weaken the generalizability evidence for the claimed "organ-aware" capability. Another reviewer also noted potential class imbalance in the organ labels and suggested supplementing organ-coverage statistics. The reviewers also raised concerns about the availability of the internal dataset, which affects result reproducibility. Overall, SOAR's core idea demonstrates clear problem awareness and application potential. However, the current version has substantive deficiencies in terms of method positioning accuracy, fairness of baseline comparisons, completeness of ablation designs, and systematic analysis of dependence on external segmentation priors. The experimental evidence is not yet sufficient to fully support its core claims. Therefore, my inclination is toward the borderline of acceptance, and the final decision is left to the SAC.

Area Chair SYb6 · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The proposal of SOAR—to inject organ-level anatomical priors into 3D CT visual representation learning—and its core motivation of alleviating the semantic mismatch between sparse diagnostic-report supervision and dense 3D CT anatomical information, received unanimous recognition from the three reviewers. However, the reviewers' scores diverged significantly (4: Borderline Accept, 5: Accept, 2: Reject), reflecting deep-seated disagreements over the paper's technical rigor and experimental completeness. One reviewer explicitly pointed out that SOAR should not be categorized as a self-supervised method, since it relies on pseudo-labels generated by TotalSegmentator as supervisory signals, which is fundamentally different from truly self-supervised pre-training approaches such as MAE. Therefore, the authors must supplement fair comparisons with supervised pre-training baselines (e.g., MedVAE, Foundation VAEs, pre-trained segmentation model encoders); otherwise, the baseline selection suffers from serious unfairness. In addition, two reviewers jointly noted critical omissions in the ablation study: the paper does not perform independent on/off ablations for each loss component, making it impossible to assess the necessity and individual contribution of each component. Moreover, a comparison between PubMedBERT embeddings and simple fixed class tokens is missing, which is essential to support the claimed technical contribution of "organ-level visual-language alignment." Regarding the evaluation scope, two reviewers pointed out that the current qualitative examples are overly focused on the lungs, the pre-training data is limited to non-contrast chest CTs, and fine-grained downstream tasks such as segmentation and detection are absent—all of which weaken the generalizability evidence for the claimed "organ-aware" capability. Another reviewer also noted potential class imbalance in the organ labels and suggested supplementing organ-coverage statistics. The reviewers also raised concerns about the availability of the internal dataset, which affects result reproducibility. Overall, SOAR's core idea demonstrates clear problem awareness and application potential. However, the current version has substantive deficiencies in terms of method positioning accuracy, fairness of baseline comparisons, completeness of ablation designs, and systematic analysis of dependence on external segmentation priors. The experimental evidence is not yet sufficient to fully support its core claims. Therefore, my inclination is toward the borderline of acceptance, and the final decision is left to the SAC.

1 comment
Authors · CommentOpenReview ↗

Summary of the Reviewers' Main Concerns and Our Responses

We thank the Area Chair for the constructive summary of the key concerns. Below we consolidate our responses to the main points raised in the meta-review and by the reviewers. We have also provided point-by-point responses to all the comments and conducted all the experiments requested in the review.

We are also grateful to the reviewers for their encouraging remarks.

  • ZNxd highlighted the clear motivation, simple design, and broad evaluation.
  • Vm6a emphasized SOAR's novelty, clinical grounding, and comprehensive validation.
  • PZ3k recognized SOAR's strong generalization and consistent improvements across downstream tasks.

Summary of Reviewer Concerns and Responses

Concern Response
Classification as self-supervised learning (PZ3k-W2) “Self-supervised” appears only once in Related Work (Line 101) in the cautious phrase “can also be viewed as”, which intended only to convey that SOAR requires neither manual annotation of its pretraining scans nor paired radiology reports. It is absent from the title, abstract, contributions, and framing. We will remove this wording and clarify the use of externally supervised TotalSegmentator pseudo-labels.
Missing baselines (PZ3k-W2; ZNxd-W2) We compared SOAR with additional reviewer-suggested baselines, which it outperforms by 0.55–14.17 points. As suggested by the reviewers, to show that these gains cannot be attributed solely to the segmentation prior, we also disentangled its contribution and compared SOAR with segmentation-only baselines, which it outperforms by 1.56–7.30 points.
Missing component-wise loss ablations (PZ3k-W1) We added the requested ablation studies. The proposed SOAR components consistently provide robust overall performance across VQA and detection tasks.
Missing comparison with fixed class tokens (PZ3k-W3) PubMedBERT-derived organ embeddings outperform fixed class tokens by 3.50–6.66 points, confirming the value of semantic organ information.
Lack of broader qualitative examples / evaluation scope (ZNxd-W3) We added qualitative examples involving the upper abdomen, adrenal glands, and renal lesions and will include them in the revised manuscript to demonstrate broader anatomical generalizability beyond lung-focused cases.
Limited anatomical coverage and organ-label imbalance (Vm6a-W2) Statistics from 50,185 CT-RATE volumes show that, although the pretraining dataset consists of chest CT scans, its anatomical coverage is not limited to the lungs: it provides broad thoracic and upper-abdominal coverage, with 82 of 117 structures defined by TotalSegmentator appearing in at least 90% of scans. SOAR also performs best on AMOS-MM, demonstrating strong generalization to abdominal CT. Complete per-structure statistics will be added to the revised manuscript.
Missing segmentation and detection evaluation (PZ3k-W4) The manuscript already includes multiple detection tasks. We additionally evaluated different methods segmentation downstream task, where SOAR achieves the highest mean Dice score of 0.897.
Internal dataset availability and reproducibility (PZ3k-W6) The esophageal cancer dataset can be shared through a standard data transfer agreement. We will also release the pretrained weights and code.

We thank the Area Chair and reviewers again for their valuable guidance, which has improved the clarity and completeness of our work. As the discussion window is closing, we hope our responses have addressed the concerns and remain glad to discuss any remaining points.

Reviewer PZ3kOpenReview ↗
Rating
2/6
Confidence
4/5
Quality
1/4
Clarity
3/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The authors introduce SOAR, a pre-training method for CT imaging. SOAR consists of three main components: organ-level masked reconstruction, organ-level vision-language alignment, and organ-level supervision, which are combined in one objective with the aim of pre-training a ViT vision encoder for downstream application. They experiment with multiple tasks and demonstrate performance superior to self-supervised baselines.

Strengths and weaknesses

I read the paper in detail and found several strengths and weaknesses:

Strengths:

  • Experimental results including selected metrics are quite elaborate and conducted on multiple datasets.
  • SOAR generalizes well to multiple downstream tasks.
  • SOAR, in general, outperforms self-supervised baselines on the presented tasks.
  • SOAR is well-motivated. The task of foundational ViT CT pre-training is relevant to the community and could potentially benefit multiple applications.
  • The method is in general easy to follow.
  • The authors claim that code will be available.

Weaknesses:

  • Extremely underwhelming and confusing ablation studies. It is unclear to me how ‘replacing random patch masking with random organ masking improves multiple-choice accuracy from 85.76% to 88.64%’ (L314-315), given that Tab3 exclusively compares the number of classes used for masking, L_organ-super, and the use of organ-specific mask tokens in L_organ-recon, and L_organ-align. The method consists of three loss components: L_organ-super, L_organ-recon, and L_organ-align. There is no ablation on switching individual loss components off, which would yield insights into their necessity. Further, ablations of core components should be conducted on multiple downstream tasks.
  • Missing baselines. Given that the model uses ground truth labels for pre-training, it does not classify as self-supervised. I, therefore, disagree strongly with the authors statement: 'SOAR can also be viewed as a self-supervised pre-training method, since it does not rely on manual anatomical annotations but instead uses automatically derived anatomical priors from medical image segmentation foundation models' (L100-103). Given that, it is essential to compare to supervised baselines, such as [1, 2, 3] or simply encoders of pre-trained anatomical segmentation models such as [4, 5, 6].
  • Conceptual issues. The Organ-level Vision-language Alignment module is not based on reports, but rather on simple class labels and does therefore not account for abnormal structures and diseases. Further, simple alignment to an embedding derived from the class name is far from ‘vision-language alignment’. I am interested in seeing the performance of SOAR if their tokens derived from PubMedBERT are exchanged with simple, fixed class tokens. This needs to be ablated in detail.
  • Missing downstream tasks. It would be interesting to see SOAR’s performance on segmentation and detection tasks.
  • No statistical significance for ablation results. These are necessary, given low performance delta in Tab3.
  • It is unclear whether their in-house esophageal cancer screening dataset will be release to the public.
  • SOAR depends heavily on TotalSegmentator, which does not represent the state-of-the-art [5]. It is therefore inherently limited to CT (and MR) images.

In summary, the weaknesses clearly outweigh the strengths of this paper. In particular, the ablations are incomplete and the baseline selection is unfair, which prevents a valid assessment of SOAR's contribution. Although the paper is well-motivated and there is a clear need of foundational CT encoders in the medical community, I can not recommend to accept SOAR at NeurIPS.

[1] Varma, Maya, et al. "MedVAE: Efficient automated interpretation of medical images with large-scale generalizable autoencoders." arXiv preprint arXiv:2502.14753 (2025).
[2] Chen, Qi, et al. "Foundation VAEs for 3D CT Reconstruction, Augmentation, and Generation." arXiv preprint arXiv:2605.30893 (2026).
[3] Guo, Pengfei, et al. "Maisi: Medical ai for synthetic imaging." 2025 IEEE/CVF Winter Conference on Applications of Computer Vision (WACV). IEEE, 2025.
[4] Wasserthal, Jakob, et al. "TotalSegmentator: robust segmentation of 104 anatomic structures in CT images." Radiology: Artificial Intelligence 5.5 (2023): e230024.
[5] Xu, Murong, et al. "CADS: A Comprehensive Anatomical Dataset and Segmentation for Whole-Body Anatomy in Computed Tomography." arXiv preprint arXiv:2507.22953 (2025).
[6] He, Yufan, et al. "VISTA3D: A unified segmentation foundation model for 3D medical imaging." Proceedings of the Computer Vision and Pattern Recognition Conference. 2025.

Questions

Suggestion: Please compare to supervised baselines for fair comparison.
Suggestion: SOAR needs to be ablated in detail (each introduced component individually).
Suggestion: I would appreciate downstream experiments on segmentation tasks.

Limitations

yes

Final justification

As discussed in the rebuttal, I find the paper's framing issues to be deeply rooted. Even though the authors have backtracked on positioning SOAR as self-supervised, I believe that all experimental results require comparison against multiple fully supervised baselines - verification that goes beyond what can be done within the narrow time frame of the rebuttal period. Given that, I still favor rejecting the paper.

Formatting concerns

none

5 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Dear Reviewer PZ3k, we sincerely thank you for your thoughtful and constructive feedback. We address each point below.

W1 Extremely underwhelming and confusing ...

The apparent discrepancy arises because these results appear in different tables: 85.76% is the random-patch MAE baseline in Table 1, whereas 88.64% is the organ-level reconstruction model with 30 masked organs in Table 3. We will add the MAE baseline to Table 3 in the revised paper.

Regarding ablation studies of different losses, presented below, we performed the requested ablation study in the manuscript. Each component is isolated through a paired comparison. Δ\Delta denotes the change relative to the preceding configuration.

Configuration VQA Acc (%) Δ\Delta
Random-patch MAE (no organ-level losses) 85.76 —
Lorgan-recon\mathcal{L}_{\text{organ-recon}} only 88.64 +2.88+2.88
+Lorgan-super+\mathcal{L}_{\text{organ-super}} 89.37 +0.73+0.73
+Lorgan-align+\mathcal{L}_{\text{organ-align}} (i.e., Full SOAR) 89.87 +0.50+0.50
Full SOAR w/o organ-conditioned mask tokens 89.63 −0.24-0.24

Following the reviewer’s suggestion, we further evaluated all six ablation configurations on pneumonia classification and CT-RATE abnormality detection. As shown below, the proposed SOAR (last row) consistently provides robust overall performance across VQA and detection tasks.

Best results are shown in bold, and second-best results are underlined‾\underline{\text{underlined}}.

Organ-level reconstruction (# masked organs) Organ-level supervision Organ-conditioned mask tokens Organ-level alignment COVID-19 Common pneumonia Normal Average CT-RATE abnormality detection
✓ (10) 96.25 95.43 95.61 95.76 74.12
✓ (30) 97.52 96.66 97.59 97.26 74.71‾\underline{74.71}
✓ (60) 95.69 94.51 94.97 95.06 74.00
✓ (30) ✓ 97.67 96.39 97.19 97.08 73.23
✓ (30) ✓ ✓ 98.03‾\underline{98.03} 97.30‾\underline{97.30} 97.62‾\underline{97.62} 97.58‾\underline{97.58} 74.28
✓ (30) ✓ ✓ ✓ 98.79 97.47 97.72 97.99 75.38

W2 Missing baselines. ......

We would like to clarify that SOAR does not use ground-truth anatomical labels during pretraining. As stated in Lines 100–103, manual organ annotations are unavailable for our pretraining dataset; instead, a frozen, open-source TotalSegmentator automatically derives coarse anatomical masks used only as auxiliary spatial priors, not as ground-truth supervision.

Among the six suggested baselines, MedVAE [1] provides a directly transferable CT encoder, whereas Foundation VAE [2] does not introduce or train a method-specific CT encoder and is contemporaneous work under the NeurIPS 2026 policy. MAISI [3] is a diffusion-based CT synthesis framework without a visual-token interface for downstream understanding and is therefore outside our scope. References [4–6] are segmentation foundation models. We therefore added two representative and directly comparable baselines: MedVAE [1] and TotalSegmentator [4]. We selected TotalSegmentator because it is the exact pseudo-label generator used by SOAR, making its encoder the most direct segmentation-only control for determining whether SOAR’s performance is inherited from segmentation pretraining.

As shown below, SOAR outperforms MedVAE by 0.55–14.17 points and the TotalSegmentator encoder by 1.60–7.30 points across all CT-RATE VQA metrics, confirming SOAR’s superior performance over both autoencoder- and segmentation-based baselines.

Each Δ\Delta denotes SOAR’s improvement over the corresponding baseline.

Task Metric MedVAE TotalSegmentator SOAR ΔMedVAE\Delta_{\text{MedVAE}} ΔTotalSeg\Delta_{\text{TotalSeg}}
Closed-ended VQA Accuracy (%) 75.70 87.12 89.87 ↑14.17\uparrow 14.17 ↑2.75\uparrow 2.75
Open-ended VQA BLEU-1 44.29 41.97 49.27 ↑4.98\uparrow 4.98 ↑7.30\uparrow 7.30
BLEU-2 34.21 33.20 38.19 ↑3.98\uparrow 3.98 ↑4.99\uparrow 4.99
ROUGE-1 50.49 49.76 54.65 ↑4.16\uparrow 4.16 ↑4.89\uparrow 4.89
METEOR 45.84 46.67 51.15 ↑5.31\uparrow 5.31 ↑4.48\uparrow 4.48
BERT-F1 91.45 90.40 92.00 ↑0.55\uparrow 0.55 ↑1.60\uparrow 1.60

W3 Conceptual issues ......

We agree that our pretraining objective does not use radiology reports and therefore does not explicitly inject disease or abnormality semantics. Instead, SOAR preserves fine-grained visual information in anatomically grounded visual tokens through reconstruction and structural learning. During downstream instruction tuning, the LLM learns to associate these visual features with disease concepts and findings. The superior performance across the downstream benchmarks reported in the paper demonstrates the effectiveness of this design.

Following the reviewer’s suggestion, we replaced the PubMedBERT-derived organ embeddings with fixed class tokens and retrained the encoder under identical settings. Presented below, the results on pneumonia and abnormality detection show that PubMedBERT-derived organ embeddings provide more effective supervision than simple class identifiers.

All results are AUC (%). Δ\Delta denotes the improvement of SOAR over the fixed-class-token model.

Benchmark Task/Class Fixed class token SOAR Δ\Delta
Pneumonia classification COVID-19 93.21 98.79 ↑5.58\uparrow 5.58
Common pneumonia 90.81 97.47 ↑6.66\uparrow 6.66
Normal 94.22 97.72 ↑3.50\uparrow 3.50
Average 92.75 97.99 ↑5.24\uparrow 5.24
CT-RATE abnormality Average 70.90 75.38 ↑4.48\uparrow 4.48

W4 Missing downstream tasks. ......

Detection: We would like to draw your attention to Tables 1-2 that evaluate SOAR on detection-oriented tasks, including anatomy and abnormality detection in 3D-RAD and AMOS-MM, scan-level disease detection, and 18-class abnormality detection on CT-RATE. Together, they assess whether SOAR representations capture the presence of anatomical structures and abnormalities.

Segmentation: We agree that the original evaluation did not include segmentation. SOAR is designed primarily to produce fine-grained visual tokens for CT understanding tasks such as VQA and report generation. We therefore initially focused on these understanding tasks. Moreover, because SOAR pretraining already includes an auxiliary segmentation loss, a segmentation evaluation could inherently favor SOAR.

To fully address your concern, we evaluated all frozen encoders on KiTS19 using the same segmentation decoder and training protocol. SOAR achieves the highest mean Dice score of 0.897, compared with 0.726 for MAE, 0.663 for CLIP, 0.681 for fVLM, 0.837 for ViSD, and 0.868 for VoCo.

W5 No statistical significance for ablation results. ......

We appreciate this suggestion. We performed paired t-tests on the per-example open-ended VQA scores and added the results to the original Table 3 of the manuscript. As shown in the table below, full SOAR significantly outperforms the ablated models on most metrics.

Numbers in parentheses indicate the number of masked organs used during pretraining. Superscripts report paired t-test significance against the full SOAR model in the last row: *p<0.05$, **p<0.005, and ***p<0.00005.

Organ-level reconstruction (# masked organs) Organ-level supervision Organ-conditioned mask tokens Organ-level alignment Multiple-choice accuracy (%) BLEU-1 BLEU-2 ROUGE-1 METEOR BERT-F1 GREEN
✓ (10) 84.44 48.37$^{***}$ 37.25$^{***}$ 53.57$^{***}$ 50.46$^{***}$ 91.86$^{***}$ 45.44$^{***}$
✓ (30) 88.64 48.88$^{***}$ 38.02$^{*}$ 54.36$^{***}$ 50.76$^{***}$ 91.94$^{***}$ 46.53$^{**}$
✓ (60) 85.79 48.16$^{***}$ 37.63$^{***}$ 53.82$^{***}$ 50.46$^{***}$ 91.86$^{***}$ 46.37$^{***}$
✓ (30) ✓ 89.37 49.05$^{**}$ 38.17 54.56 50.88$^{***}$ 91.92$^{***}$ 46.22$^{***}$
✓ (30) ✓ ✓ 89.63 48.78$^{***}$ 37.94$^{**}$ 54.24$^{***}$ 50.71$^{***}$ 91.90$^{***}$ 46.14$^{***}$
✓ (30) ✓ ✓ ✓ 89.87 49.27 38.19 54.65 51.15 92.00 46.83

W6 It is unclear whether their in-house esophageal cancer screening dataset will be release to the public.

The in-house esophageal cancer screening dataset was obtained under a data transfer agreement with the providing hospital. It can be made available to qualified researchers through a standard and straightforward data transfer agreement process. We will clarify this procedure in the revised Data Availability statement and release our pretrained weights and source code.

W7 SOAR depends heavily on TotalSegmentator, .... It is therefore inherently limited to CT (and MR) images.

We respectfully clarify that SOAR is not inherently tied to TotalSegmentator. It serves only as an offline pseudo-label generator and can be replaced by any compatible anatomical segmentation model without modifying SOAR’s architecture or objectives. Therefore, developing or using a particular state-of-the-art segmentation architecture is not a prerequisite of SOAR.

We selected TotalSegmentator because it is a mature and widely adopted community tool. According to its paper, it was validated on heterogeneous routine clinical CT data spanning different scanners, sites, protocols, body regions, and major pathologies. Importantly, its documented training data exclude CT-RATE, whereas CADS [5] was trained on 3,134 CT-RATE volumes, creating potential data overlap.

Finally, the present work is intentionally scoped to 3D CT understanding, as explicitly stated in the title; extending SOAR to other modalities remains future work.

Reviewer PZ3k · CommentOpenReview ↗

I thank the authors for providing a rebuttal. While I think their additional ablations on all loss terms and provided statistical significance for ablation results strengthen the paper significantly, my main concern regarding the paper's overall framing remains.

We would like to clarify that SOAR does not use ground-truth anatomical labels during pretraining. As stated in Lines 100–103, manual organ annotations are unavailable for our pretraining dataset; instead, a frozen, open-source TotalSegmentator automatically derives coarse anatomical masks used only as auxiliary spatial priors, not as ground-truth supervision

I understand that this work does not use manual annotations directly. However, relying heavily on segmentation masks derived from a model that was itself trained on a large amount of manually annotated data does not make the paper "self-supervised." SOAR even includes an organ-level supervision loss based on TotalSegmentator-derived segmentation masks, which goes well beyond, to quote the rebuttal, "coarse anatomical masks used only as auxiliary spatial priors, not as ground-truth supervision." The paper itself states that its "organ-level supervision objective enforces voxel-level spatial discrimination across all organ boundaries." One could reasonably view SOAR as a form of distilled TotalSegmentator. On that basis, the method needs to be compared against fitting baselines across all tasks involved.

Given this significant framing concern, combined with the conceptual issues raised earlier (namely, that simple alignment to an embedding derived from the class name falls far short of "vision-language alignment", see review), I cannot recommend acceptance. I would advise the authors to substantially reframe the manuscript and thank them for their effort.

Authors · CommentOpenReview ↗

We thank the reviewer for the continued and careful engagement, and for acknowledging that our additional loss ablations and statistical-significance analyses strengthen the paper. We address the three remaining points in turn.

(1) SOAR is not centrally positioned as self-supervised, and we will make this explicit. The term appears only once (Related Work, Line 101) in the cautious phrase “can also be viewed as,” which was only meant to convey that SOAR requires neither manual annotation of its pretraining scans nor paired radiology reports. It does not appear in SOAR’s title, abstract, contribution summary, or framing. To remove any ambiguity, we will delete that sentence and describe SOAR more precisely. A frozen, external TotalSegmentator generates anatomical pseudo-labels that are used only during pretraining to encourage the encoder to preserve voxel-level anatomical information. We acknowledge that TotalSegmentator itself inherits supervision from manually annotated datasets. This wording change affects positioning only, not the method, results, or contributions.

(2) SOAR is not merely TotalSegmentator distillation, as supported by direct empirical comparisons. We agree that this should be settled by evidence rather than wording. First, SOAR does not distill TotalSegmentator’s logits, features, or reproduce its segmentation architecture. After pretraining, TotalSegmentator and all auxiliary decoders are discarded, and only the pretrained visual encoder is fine-tuned downstream. Thus, TotalSegmentator is never required during fine-tuning or inference. Second, if SOAR were merely a distilled version of TotalSegmentator, directly transferring TotalSegmentator’s own encoder would be expected to provide a strong competitive baseline. Instead, under the same downstream protocol, SOAR outperforms the TotalSegmentator encoder on every downstream VQA metric by 1.60–7.30 points. We also added the requested downstream segmentation comparison in our previous response. Moreover, segmentation guidance does not by itself make the resulting encoder equivalent to a distilled segmentor: two baselines discussed in our Related Work, fVLM [30] and ViSD [31], also incorporate segmentation guidance. SOAR differs by using automatically generated organ masks to pretrain a transferable 3D CT encoder for broad understanding tasks, without requiring manual annotations or labels for the pretraining scans. To fully address the reviewer’s request for comparisons “across all tasks,” we add a unified table comparing SOAR against the TotalSegmentator encoder and representative methods with and without segmentation guidance across VQA, disease screening, and abnormality detection. Due to space limitations, the table is provided in the following official comment.

(3) Terminology and semantic alignment. We agree that aligning organ regions with organ-name embeddings is narrower than general vision-language alignment involving reports or rich clinical descriptions. We will rename this component organ-text semantic alignment and narrow the associated claims throughout the manuscript. Specifically, we will clarify that it injects organ-name-level semantics during visual pretraining, whereas downstream language reasoning is learned through task-specific fine-tuning. Extending SOAR to report- or finding-level supervision is a clear direction for future work. Nonetheless, the proposed organ-text semantic alignment provides measurable benefits: replacing the PubMedBERT-derived organ-name embeddings with fixed class tokens under otherwise identical settings decreases the mean pneumonia AUC from 97.99% to 92.75% and the CT-RATE abnormality AUC from 75.38% to 70.90%. These results show that semantic organ-name embeddings provide guidance beyond simple organ-class identifiers.

None of these changes alters SOAR’s core contribution or empirical findings: integrating organ-level masked reconstruction, voxel-level anatomical preservation, and organ-text semantic alignment yields more transferable 3D CT representations than pretraining without organ awareness, with consistent gains across various downstream tasks, as verified in Tables 1-3. To support verification and reuse, we will release the source code, pretrained weights, and complete training protocol.

Reviewer Vm6aOpenReview ↗
Rating
6/6
Confidence
5/5
Quality
3/4
Clarity
3/4
Significance
4/4
Originality
4/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper presents SOAR, a novel pretraining framework for 3D CT image understanding that incorporates automatically generated organ masks as fine-grained anatomical priors. Its motivation is clear: conventional CLIP-style vision-language pretraining is often too coarse for 3D CT, as it aligns whole volumes with sparse diagnostic reports and provides limited supervision for local anatomical structures. To address this issue, SOAR integrates organ-level masked reconstruction, organ-level vision-language alignment, and auxiliary organ segmentation supervision. Experiments on VQA, report generation, and abnormality detection across multiple medical imaging benchmarks show consistent improvements over recent baselines, while ablation studies further validate the effectiveness of its key components.

Strengths and weaknesses

Strengths

  • The paper is easy to follow and addresses an important and timely problem in 3D medical imaging.
  • The proposed method is novel, intuitive, and clinically grounded, effectively incorporating anatomical structures into medical vision pretraining.
  • The authors conduct broad and diverse evaluations across multiple datasets and downstream tasks, together with well-designed ablation studies, to demonstrate the effectiveness of the proposed framework and validate the contribution of each component.

Weaknesses

  • The organ-level vision-language alignment mainly uses organ-name prompts rather than disease-aware or finding-aware text. This design is effective for anatomical grounding, but it may not fully capture fine-grained pathological semantics.
  • The pretraining data are mainly chest and abdominal CT from CT-RATE. The organ labels could be highly imbalanced. Reporting organ coverage statistics would help clarify the robustness of the organ-level objectives.
Questions

See Weaknesses.

Limitations

Yes.

Final justification

I remain convinced of the novelty and feasibility of the proposed framework and appreciate that the authors have clearly explained its key details. I strongly support acceptance of this paper.

Formatting concerns

No.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Dear Reviewer Vm6a, We sincerely thank you for your thoughtful and constructive feedback. We address each point below.

W1: The organ-level vision-language alignment mainly uses organ-name prompts rather than disease-aware or finding-aware text. This design is effective for anatomical grounding, but it may not fully capture fine-grained pathological semantics.

We appreciate this important observation. SOAR does not explicitly inject disease semantics during pretraining; instead, it preserves fine-grained visual information in anatomically grounded visual tokens through reconstruction and structural learning. During downstream instruction tuning, the LLM learns to associate these visual features with disease concepts and findings. Despite using only organ-name prompts during pretraining, SOAR achieves the best results across all anomaly-detection metrics on 3D-RAD and the highest disease-analysis accuracy on AMOS-MM, supporting the effectiveness of this training strategy. We explicitly acknowledge this design scope in Appendix C.

W2: The pretraining data are mainly chest and abdominal CT from CT-RATE. The organ labels could be highly imbalanced. Reporting organ coverage statistics would help clarify the robustness of the organ-level objectives.

We appreciate this helpful suggestion. As shown below, we computed organ-presence statistics from the TotalSegmentator masks across 50,185 valid CT-RATE volumes. Although coverage is imbalanced, it remains broad: 69 of 117 structures occur in at least 98% of volumes, and 82 occur in at least 90%. Coverage is nearly complete for thoracic structures, including the lung lobes (98.37%-98.45%) and heart (98.37%), and remains high for abdominal structures, including the liver (98.36%), spleen (98.18%), stomach (98.31%), pancreas (97.84%), kidneys (93.91%-96.10%), duodenum (92.56%), and colon (95.72%). Cranial and distal lower-body structures occur less frequently because they are not consistently included in routine thoracoabdominal CT acquisition ranges; for example, the skull appears in (43.07%) of volumes.

Consistent with this broad abdominal coverage, SOAR achieves the best average performance on AMOS-MM, an abdominal CT benchmark. We will include the complete 117-class coverage statistics in the revision and release our pretrained weights and source code.

ID Organ Cov.(%) # Vol. ID Organ Cov.(%) # Vol. ID Organ Cov.(%) # Vol.
1 spleen 98.18 49272 40 vertebrae_T4 98.36 49363 79 spinal_cord 99.96 50164
2 kidney_right 93.91 47131 41 vertebrae_T3 98.39 49376 80 gluteus_maximus_left 0.54 270
3 kidney_left 96.10 48230 42 vertebrae_T2 98.39 49377 81 gluteus_maximus_right 0.28 143
4 gallbladder 88.02 44172 43 vertebrae_T1 98.39 49379 82 gluteus_medius_left 0.42 210
5 liver 98.36 49361 44 vertebrae_C7 97.68 49020 83 gluteus_medius_right 0.41 208
6 stomach 98.31 49336 45 vertebrae_C6 73.44 36856 84 gluteus_minimus_left 0.16 82
7 pancreas 97.84 49101 46 vertebrae_C5 28.59 14349 85 gluteus_minimus_right 0.17 83
8 adrenal_gland_right 97.74 49050 47 vertebrae_C4 5.09 2554 86 autochthon_left 98.57 49469
9 adrenal_gland_left 97.29 48827 48 vertebrae_C3 2.40 1204 87 autochthon_right 98.53 49449
10 lung_upper_lobe_left 98.45 49407 49 vertebrae_C2 2.12 1062 88 iliopsoas_left 88.44 44382
11 lung_lower_lobe_left 98.41 49388 50 vertebrae_C1 2.09 1050 89 iliopsoas_right 90.44 45387
12 lung_upper_lobe_right 98.43 49398 51 heart 98.37 49368 90 brain 3.25 1631
13 lung_middle_lobe_right 98.37 49369 52 aorta 98.40 49384 91 skull 43.07 21617
14 lung_lower_lobe_right 98.41 49385 53 pulmonary_vein 98.32 49341 92 rib_left_1 98.22 49293
15 esophagus 98.44 49403 54 brachiocephalic_trunk 98.20 49282 93 rib_left_2 98.24 49304
16 trachea 98.49 49428 55 subclavian_artery_right 98.28 49320 94 rib_left_3 98.39 49375
17 thyroid_gland 98.36 49361 56 subclavian_artery_left 98.29 49329 95 rib_left_4 98.37 49367
18 small_bowel 89.55 44941 57 common_carotid_artery_right 98.24 49303 96 rib_left_5 98.36 49364
19 duodenum 92.56 46450 58 common_carotid_artery_left 98.36 49360 97 rib_left_6 98.37 49366
20 colon 95.72 48036 59 brachiocephalic_vein_left 98.26 49310 98 rib_left_7 98.36 49364
21 urinary_bladder 1.29 649 60 brachiocephalic_vein_right 98.27 49319 99 rib_left_8 98.35 49358
22 prostate 0.14 69 61 atrial_appendage_left 98.13 49246 100 rib_left_9 98.34 49352
23 kidney_cyst_left 3.16 1586 62 superior_vena_cava 98.32 49340 101 rib_left_10 98.32 49340
24 kidney_cyst_right 4.20 2110 63 inferior_vena_cava 98.34 49353 102 rib_left_11 98.23 49298
25 sacrum 1.76 882 64 portal_vein_and_splenic_vein 96.67 48513 103 rib_left_12 95.01 47681
26 vertebrae_S1 0.37 184 65 iliac_artery_left 0.76 380 104 rib_right_1 98.22 49293
27 vertebrae_L5 1.00 500 66 iliac_artery_right 0.85 425 105 rib_right_2 98.25 49305
28 vertebrae_L4 5.72 2871 67 iliac_vena_left 0.46 231 106 rib_right_3 98.38 49371
29 vertebrae_L3 32.96 16539 68 iliac_vena_right 0.39 198 107 rib_right_4 98.37 49369
30 vertebrae_L2 75.66 37968 69 humerus_left 98.14 49252 108 rib_right_5 98.37 49365
31 vertebrae_L1 94.30 47323 70 humerus_right 98.16 49262 109 rib_right_6 98.37 49366
32 vertebrae_T12 98.00 49182 71 scapula_left 98.47 49416 110 rib_right_7 98.36 49363
33 vertebrae_T11 98.28 49324 72 scapula_right 98.46 49413 111 rib_right_8 98.36 49360
34 vertebrae_T10 98.32 49344 73 clavicula_left 98.44 49400 112 rib_right_9 98.34 49351
35 vertebrae_T9 98.35 49356 74 clavicula_right 98.44 49403 113 rib_right_10 98.32 49344
36 vertebrae_T8 98.34 49351 75 femur_left 1.59 796 114 rib_right_11 98.24 49300
37 vertebrae_T7 98.35 49356 76 femur_right 0.66 329 115 rib_right_12 95.10 47728
38 vertebrae_T6 98.33 49348 77 hip_left 6.06 3040 116 sternum 98.38 49372
39 vertebrae_T5 98.35 49356 78 hip_right 3.24 1625 117 costal_cartilages 98.40 49380
Reviewer Vm6a · CommentOpenReview ↗

I thank the authors for their detailed rebuttal. Their clearer explanation of organ-level vision–language alignment, additional organ-coverage statistics, comparisons with segmentation-based baselines, a class-token replacement experiment, and robustness analysis under noisy pseudo-labels have adequately addressed my main concerns and provided stronger empirical support for the proposed organ-level components. Overall, I find the framework technically meaningful and well validated, with a novel organ-aware pretraining strategy that may benefit transferable representation learning for 3D CT understanding. I have therefore increased my score from 5 to 6 and support acceptance.

Authors · CommentOpenReview ↗

Dear Reviewer Vm6a,

We sincerely thank you for your positive feedback and for acknowledging that our rebuttal has addressed your concerns. We appreciate your recognition of the technical contribution and empirical validation of our work.

We will incorporate the discussed improvements into the next version of our manuscript and make the pretrained weights and code publicly available to the community.

Thank you again for your valuable time and constructive guidance.

Best regards,
Authors.

Reviewer ZNxdOpenReview ↗
Rating
4/6
Confidence
2/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes SOAR, a 3D CT pretraining framework that uses automatically generated organ segmentation masks to inject organ-level structure and semantics into visual representation learning. The method combines three objectives, organ-level masked reconstruction, organ-level vision-language alignment using organ-name prompts, and an auxiliary organ segmentation loss. The authors pretrain on CT-RATE and evaluate on multiple downstream tasks, including VQA, disease screening, and abnormality detection, reporting consistent gains over MAE, CLIP, fVLM, ViSD, and VoCo. The main claim is that organ-aware supervision reduces the semantic mismatch of report-based 3D CT pretraining and yields more transferable CT representations.

Strengths and weaknesses

Strengths

  1. Clear and well-motivated problem setting: The paper identifies a plausible mismatch between dense anatomical information in 3D CT and sparse report-based supervision, and Figure 1 illustrates this issue effectively. Using organs as an intermediate unit of supervision is a natural and intuitive design choice.

  2. Simple method with reasonably broad evaluation: Figure 2 clearly presents the three components—organ-level reconstruction, segmentation supervision, and vision-language alignment—and the overall framework is modular. The experiments cover multiple VQA, disease screening, and abnormality detection tasks, providing reasonably broad evidence of effectiveness.

  3. Results generally support the central hypothesis: SOAR is competitive on most tasks in Tables 1 and 2. Table 3 suggests that the proposed components may provide complementary benefits, while Figure 3 offers preliminary qualitative support for improved anatomical localization.

Weaknesses

  1. The degree of technical novelty remains somewhat unclear: The method mainly combines organ-guided masking, regional feature aggregation, contrastive learning, and auxiliary segmentation at the organ level. A more systematic comparison with closely related work would help clarify the exact technical contribution.

  2. The role of the external segmentation prior is not sufficiently disentangled: SOAR relies on pseudo-labels generated by TotalSegmentator, but the paper lacks a segmentation-only baseline, robustness tests under noisy pseudo-labels, and controls with matched masking ratios. As a result, the independent contribution of each design choice is not fully established.

  3. The strength of the results and the scope of generalization remain limited: Some gains are small and SOAR is not consistently best across all metrics. The qualitative examples are mainly lung-focused, and pretraining is conducted primarily on non-contrast chest CT, so broader applicability to general 3D CT settings requires further validation.

Questions
  1. Robustness to pseudo-label quality: Can the authors evaluate how SOAR performs when TotalSegmentator masks are degraded, partially removed, or merged into coarser anatomical groups? A lightweight sensitivity analysis would help clarify the method’s dependence on the quality and granularity of the external segmentation prior.

  2. Broader qualitative evidence: Can the authors provide one or two abdominal or multi-organ qualitative examples, preferably from AMOS-MM, to better support the broader organ-aware claim beyond the predominantly pulmonary cases currently shown?

I have limited familiarity with this specific research area and will therefore also take the other reviewers’ comments and assessments into account when forming my final judgment.

Limitations

yes

Final justification

The rebuttal addresses most of my empirical concerns. The added TotalSegmentator baseline, distorted-mask experiment, and masking-ratio analysis better disentangle the contribution of the proposed organ-aware objectives, while the additional abdominal examples strengthen the evidence for generalization beyond chest CT. My main remaining reservation is the degree of technical novelty: although the rebuttal clarifies the distinction from related methods, I still view SOAR primarily as an effective integration of existing techniques around fine-grained organ-aware supervision. Overall, the rebuttal provides meaningful additional evidence and resolves most of my original concerns, so I maintain my positive recommendation.

Formatting concerns

No major issues.

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Dear Reviewer ZNxd, we sincerely thank you for your thoughtful and constructive feedback. We address each point below.

W1: The degree of technical novelty remains somewhat unclear: The method mainly combines organ-guided masking, regional feature aggregation, contrastive learning, and auxiliary segmentation at the organ level. ......

We thank you for requesting clearer positioning. SOAR's technical novelty lies in reformulating 3D CT pretraining around fine-grained organs as the fundamental supervision units. Specifically, it combines organ-level masking with organ-conditioned tokens, report-free organ-level vision-language alignment, and voxel-level anatomical supervision to jointly learn structural and semantic representations. Unlike MAE, CLIP, and VoCo, SOAR explicitly models organ identity; unlike fVLM and ViSD, it preserves the original 117-class anatomical granularity without paired reports or organ grouping. The following table presents the systematic comparison to clarify these distinctions, which will be added to the revised manuscript.

Table: Systematic comparison with closely related 3D CT pretraining methods. Unlike fVLM and ViSD, which merge fine-grained structures into broader report-aligned regions, SOAR retains the original 117-class anatomical granularity without requiring paired reports. Performance below SOAR is averaged across all 41 metrics in the manuscript.

Method Anatomical granularity Language supervision Paired reports needed Performance Compared with SOAR (%)
MAE None None No −4.07%
CLIP Global Whole radiology report Yes −5.69%
fVLM Coarse anatomical groups Report-derived regional text Yes −5.18%
ViSD Coarse anatomical groups Report-derived regional text Yes −7.41%
VoCo Spatial context None No −4.41%
SOAR 117 fine-grained structures Organ-name embeddings No Reference

W2 The role of the external segmentation prior is not sufficiently disentangled: ......

Thank you for identifying the need to better disentangle the external segmentation prior. We have added three additional experiments to address your concerns.

Segmentation-only baseline. To isolate the contribution of segmentation pretraining alone, we evaluated the pretrained TotalSegmentator encoder using the same VQA, disease-screening, and abnormality-detection protocols as the other encoders (Table A). SOAR outperforms this baseline on every metric, including +2.75 points in closed-ended VQA, +1.60–7.30 points across open-ended VQA metrics, +3.20 points in pneumonia AUC, and +6.78 points in CT-RATE abnormality AUC. Thus, SOAR's gains cannot be attributed solely to representations inherited from segmentation pretraining; the proposed organ-aware objectives substantially improve transfer to downstream CT-understanding tasks.

Robustness to noisy pseudo-labels. We retrained SOAR with partially corrupted organ masks. Pneumonia average AUC decreases from 97.99 to 87.15, and CT-RATE abnormality AUC from 75.38 to 68.13 (Table B). This result supports SOAR's motivation that accurate organ masks establish explicit correspondences between local visual regions and organ identities, enabling fine-grained anatomical representation learning. The degradation under corrupted masks confirms that SOAR benefits from meaningful anatomical priors rather than arbitrary structured masking.

Masking-ratio control. We would like to note that the 60-organ setting in Table 3 (in the paper) provides an approximate masking-ratio control for MAE. Across 1,500 sampled volumes, masking 60 organs produces a mean patch-masking ratio of 79.10% (range: 47.39%–94.97%; standard deviation: 7.75%), close to MAE's fixed 75% ratio. At this comparable ratio, the improvement over MAE is substantially smaller (85.79% vs. 85.76% accuracy; 46.37 vs. 46.18 GREEN score). This is expected because selecting more organs masks most of the volume, making organ masking increasingly similar to MAE's random masking. Among the evaluated settings, masking 30 organs achieves the best results, with 88.64% accuracy and 46.53 GREEN score.

Table A: Comparison between the TotalSegmentator encoder and SOAR across CT-RATE VQA, pneumonia classification, and CT-RATE abnormality detection. Classification results are reported as AUC (%). For each task, both encoders are evaluated under the same downstream protocol. Δ denotes the improvement of SOAR over TotalSegmentator.

Benchmark Task/Class Metric TotalSegmentator SOAR Δ
CT-RATE VQA Closed-ended VQA Accuracy (%) 87.12 89.87 ↑2.75
CT-RATE VQA Open-ended VQA BLEU-1 41.97 49.27 ↑7.30
CT-RATE VQA Open-ended VQA BLEU-2 33.20 38.19 ↑4.99
CT-RATE VQA Open-ended VQA ROUGE-1 49.76 54.65 ↑4.89
CT-RATE VQA Open-ended VQA METEOR 46.67 51.15 ↑4.48
CT-RATE VQA Open-ended VQA BERT-F1 90.40 92.00 ↑1.60
Pneumonia classification COVID-19 AUC (%) 93.95 98.79 ↑4.84
Pneumonia classification Common Pneumonia AUC (%) 94.27 97.47 ↑3.20
Pneumonia classification Normal AUC (%) 96.16 97.72 ↑1.56
Pneumonia classification Average AUC (%) 94.79 97.99 ↑3.20
CT-RATE abnormality Average AUC (%) 68.60 75.38 ↑6.78

Table B: Robustness analysis under distorted organ masks. All results are AUC (%). The distorted-mask model is pretrained using corrupted pseudo-segmentation masks. Δ denotes the improvement of SOAR over the distorted-mask model.

Benchmark Task/Class Distorted masks SOAR Δ
Pneumonia classification COVID-19 87.58 98.79 ↑11.21
Pneumonia classification Common Pneumonia 83.55 97.47 ↑13.92
Pneumonia classification Normal 90.32 97.72 ↑7.40
Pneumonia classification Average 87.15 97.99 ↑10.84
CT-RATE abnormality Average 68.13 75.38 ↑7.25

W3 The strength of the results and the scope of generalization remain limited: ......

We thank you for raising this concern. Across Tables 1–2, SOAR is best or tied on 36 of 41 reported metrics, including all primary or aggregate measures. Where it ranks second, the differences are marginal (e.g., 0.110.11 BLEU-2 and 0.070.07 METEOR).

Although CT-RATE primarily contains chest CT, SOAR’s visual representations generalize well to AMOS-MM, an abdominal CT benchmark. SOAR achieves 75.38%75.38\% average accuracy, outperforming VoCo, ViSD, and fVLM by 4.554.55, 5.415.41, and 5.455.45 percentage points, respectively. We further highlight three representative non-chest abdominal examples below. SOAR correctly identifies the absence of abnormalities in the upper abdomen and normal bilateral adrenal glands, whereas the comparison methods hallucinate unsupported findings. SOAR also precisely localizes a renal lesion to the upper pole of the right kidney, whereas the comparison methods predict the wrong structure, laterality, renal pole, or only coarse kidney localization. These quantitative and qualitative results provide direct evidence of transfer beyond chest CT. Due to limited space, additional examples will be added in the revised manuscript.

Representative abdominal VQA examples

Bold denotes correct information, whereas underlining‾\underline{\text{underlining}} denotes incorrect or unsupported information.

Case Entry Question, reference answer, or model output
Upper abdomen Question What is observed in the upper abdomen sections?
Ground truth No feature was observed in the upper abdomen sections.
MAE A 3 mm diameter calculus‾\underline{3\,\mathrm{mm}\text{ diameter calculus}} is observed in the upper pole of the left kidney.
CLIP A 16 mm diameter nodular lesion‾\underline{16\,\mathrm{mm}\text{ diameter nodular lesion}} is observed in the left adrenal gland, which is evaluated in favor of adenoma.
fVLM A 2 mm diameter calculus‾\underline{2\,\mathrm{mm}\text{ diameter calculus}} is observed in the middle part of the left kidney.
VoCo A 3 mm diameter calculus‾\underline{3\,\mathrm{mm}\text{ diameter calculus}} is observed in the middle zone of the left kidney.
ViSD A 2 mm diameter calculus‾\underline{2\,\mathrm{mm}\text{ diameter calculus}} was observed in the upper pole of the left kidney.
SOAR (Ours) No features were detected in the upper abdomen sections.
Adrenal glands Question What type of changes were observed in the bilateral adrenal glands?
Ground truth Bilateral adrenal gland calibration was normal.
MAE Diffuse thickening‾\underline{\text{Diffuse thickening}} was observed in the bilateral adrenal glands.
CLIP Diffuse thickening‾\underline{\text{Diffuse thickening}} was observed in both adrenal glands.
fVLM Diffuse thickening‾\underline{\text{Diffuse thickening}} was observed in the bilateral adrenal glands.
VoCo Nodular thickening‾\underline{\text{Nodular thickening}} was observed in the bilateral adrenal glands.
ViSD Diffuse thickening‾\underline{\text{Diffuse thickening}} was observed in both adrenal glands.
SOAR (Ours) Bilateral adrenal glands were normal, and no space-occupying lesion was detected.
Renal lesion Question Where is the hypodense, well-circumscribed lesion located?
Ground truth Upper pole of the right kidney.
MAE Lower pole‾\underline{\text{Lower pole}} of the right kidney.
CLIP Left kidney‾\underline{\text{Left kidney}}.
fVLM Right kidney.
VoCo Left adrenal gland‾\underline{\text{Left adrenal gland}}.
ViSD Right kidney.
SOAR (Ours) Right kidney upper pole.
Authors · CommentOpenReview ↗

Dear Reviewer ZNxd,

Thank you once again for your valuable and constructive feedback. We have carefully considered all of your comments and conducted additional experiments to address your concerns. In our responses, we provide further clarifications and analysis, including systematic comparisons with different methods, a new segmentation-only baseline, experiments evaluating robustness to noisy pseudo-labels and controlling for the masking ratio, and broader qualitative examples showing the generalizability of the proposed method.

As the discussion period is nearing its end, we would sincerely appreciate it if you could take a moment to review our responses. Please let us know whether they have satisfactorily addressed your concerns or whether there are any remaining questions that we can address. We truly appreciate the time and effort you have dedicated to reviewing our work.

Best regards,
The Authors.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…