potentialpaper

Roll2Depth: Zero-Shot Metric Depth Estimation Exploiting Camera's Rolling Shutter Effect

Rui Xiao, Jinming Xu, Jinsong Han

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. Accurate monocular metric depth estimation, i.e., predicting absolute depth values, is critical for applications such as robotics and augmented reality. However, existing methods often suffer from poor transferability to in-the-wild scenarios due to the lack of knowledge of camera intrinsics. In this paper, we propose a novel framework, Roll2Depth, to recover metric scale in unseen environments with unknown camera parameters. Our key idea is to leverage scene-independent physical cues induced by the rolling shutter effect of standard CMOS sensors, together with an active light source, as metric priors. When a scene is illuminated by a flickering light, the rolling shutter produces distinctive stripe-like spatial patterns, revealing the scene's shading with and without the flickering light source. This contrast encodes absolute depth cues that can be exploited for metric estimation. Roll2Depth isolates these patterns as metric priors to guide affine-invariant models on metric depth estimation in a zero-shot setting. Our evaluations on standard benchmark datasets, as well as a real-world dataset collected using commercial smartphones and our prototype system, demonstrate that Roll2Depth, as a low-cost active solution, outperforms state-of-the-art passive baselines in zero-shot settings. These results highlight its potential impact in applications such as indoor robotics and embodied perception, where affordable and effective active sensing would be valuable.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
3 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:45 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper presents a metric-scale monocular depth estimation approach. It utilizes a camera's rolling shutter effect and a flickering light source. The method leverages the resulting stripe patterns as metric priors.

Reviewers acknowledged the use of low-cost hardware to capture metric depth cues (LA7q, tK9v), the integration with diffusion priors (tK9v), and the strong evaluation results (LA7q). However, reviewers also stated several concerns. These include (1) missing comparisons against recent foundation models and active sensing baselines (LA7q, tK9v), (2) questions regarding the system's robustness under bright ambient light and on non-Lambertian surfaces (LA7q, RZqS, tK9v), and (3) questions about whether the network might hallucinate physical cues (RZqS).

In the rebuttal, the authors provided the requested comparisons against Metric3D-v2, Depth Any Camera, and Marigold-DC (LA7q, tK9v). The authors also supplied efficacy curves demonstrating stability across varying distances and ambient light levels, which helps to convince reviewers that the depth cues are physically correct rather than hallucinations (RZqS). Reviewers were largely satisfied by these additions, and Reviewer LA7q and tK9v upgraded their ratings to accept, though reviewer RZqS retained some reservations regarding the Lambertian assumptions.

Overall, AC notes that the paper presents a practical and low-cost alternative to expensive active sensors. The paper presents comprehensive ablation studies and a real-world hardware demonstration. AC recommends that the authors provide efficacy curves, ablation studies on network components, and broader baseline comparisons in the revised version.

Final justification

Please see the revised meta review.

Area Chair CCzM · Meta-reviewOpenReview ↗
Final justification
Please see the revised meta review.
Read meta-review
Meta-review

This paper presents a metric-scale monocular depth estimation approach. It utilizes a camera's rolling shutter effect and a flickering light source. The method leverages the resulting stripe patterns as metric priors.

Reviewers acknowledged the use of low-cost hardware to capture metric depth cues (LA7q, tK9v), the integration with diffusion priors (tK9v), and the strong evaluation results (LA7q). However, reviewers also stated several concerns. These include (1) missing comparisons against recent foundation models and active sensing baselines (LA7q, tK9v), (2) questions regarding the system's robustness under bright ambient light and on non-Lambertian surfaces (LA7q, RZqS, tK9v), and (3) questions about whether the network might hallucinate physical cues (RZqS).

In the rebuttal, the authors provided the requested comparisons against Metric3D-v2, Depth Any Camera, and Marigold-DC (LA7q, tK9v). The authors also supplied efficacy curves demonstrating stability across varying distances and ambient light levels, which helps to convince reviewers that the depth cues are physically correct rather than hallucinations (RZqS). Reviewers were largely satisfied by these additions, and Reviewer LA7q and tK9v upgraded their ratings to accept, though reviewer RZqS retained some reservations regarding the Lambertian assumptions.

Overall, AC notes that the paper presents a practical and low-cost alternative to expensive active sensors. The paper presents comprehensive ablation studies and a real-world hardware demonstration. AC recommends that the authors provide efficacy curves, ablation studies on network components, and broader baseline comparisons in the revised version.

2 comments
Area Chair CCzM · CommentOpenReview ↗

Dear reviewers,

I am writing to initiate the post-rebuttal discussion. Please review the authors' rebuttal and share further comments.

Thanks, AC

Authors · CommentOpenReview ↗

Summary of Rebuttal

We sincerely thank the reviewers and the Area Chair for the valuable feedback and suggestions. During the rebuttal, we conducted 8 experiments to address the individual concerns. As Phase 2 draws to a close, we provide a summary of our responses to the meta-review.

Comparison with monocular depth baselines.

  • As suggested by Reviewer LA7q, we compare Roll2Depth with Metric3D-v2 and Depth Any Camera in Table R1. Roll2Depth demonstrates strong and consistent zero-shot metric-depth performance across the benchmarks and our real-world scenes. Please see our response to W2 (Reviewer LA7q) for details.
  • As suggested by Reviewer tK9v, we compare with Marigold-DC, which uses dedicated depth sensors such as LiDAR to estimate global scale and shift. Its stronger hardware supervision provides an upper-bound reference. In contrast, Roll2Depth extracts metric information from a weaker yet low-cost photometric cue from a flickering light. Compared with existing hardware-assisted works relying on dedicated sensors like LiDAR, ToF, or RGB-D sensors, Roll2Depth occupies a practical middle ground: it introduces minimal hardware overhead but effectively improves metric depth estimation, making it suitable for cost-sensitive platforms such as smartphones, robot vacuums, and consumer-grade drones. Please see our responses to W5 (Reviewer tK9v) for details.

Relationship between rolling shutter and flickering lights. Following suggestions from Reviewer LA7q and RZqS, we clarify that the metric information in Roll2Depth originates from the collocated light source. Building on this physical principle, Roll2Depth combines rolling shutter with flickering lights as a single-shot demultiplexer to extract metric depth cues encoded by active light, thereby avoiding the motion artifacts associated with multi-frame acquisition. Please see our responses to W1 (Reviewer LA7q) and W1 (Reviewer RZqS) for details.

Bounds of distance, light brightness, and specular surfaces.

  • Following Reviewer LA7q's suggestion, we evaluate Roll2Depth under varying distances and ambient light in Tables R2 and R3. The results show that Roll2Depth maintains relatively stable performance across broad ranges of distances and SNRs. This robustness is enabled by Roll2Depth's progressive physical-cue extraction network, which can isolate subtle stripe patterns even when the active signal is attenuated. Please see our response to W3 (Reviewer LA7q) for details.
  • We also clarify Roll2Depth’s robustness to specular surfaces using two pieces of experimental evidence from Tables 7 and 2 of the main paper. Roll2Depth effectively handles non-Lambertian deviations through its affine-to-metric transformation network, which regresses global scale and shift by aggregating information across all pixels and therefore is less sensitive to local reflectance variations. Please see our response to W2 (Reviewer RZqS) for details.
  • We further discuss an extension that uses an uncertainty map to enhance robustness in our responses to L2 (Reviewer tK9v).

Ablation study on the networks.

  • Following Reviewer LA7q’s suggestion, we ablate the frequency term in Eq. 5 to isolate its contribution. As shown in Table R4, removing this term causes a noticeable performance degradation, confirming its effectiveness. Please see our response to W4 (Reviewer LA7q) for details.
  • Following Reviewer RZqS's suggestion, we analyze the intermediate signal produced by the extraction network in Tables R5 and R6. The results demonstrate that the network recovers the intended SrollnormS_{roll}^{norm} rather than a hallucinated representation. We further ablate the stripe patterns in Table R7, confirming that Roll2Depth relies on the physically correct cue-depth relationship for accurate metric depth estimation. Please see our response to W3 and W4 (Reviewer RZqS) for details.
Reviewer tK9vOpenReview ↗
Rating
5/6
Confidence
5/5
Quality
3/4
Clarity
4/4
Significance
4/4
Originality
4/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This work proposes a new approach for monocular metric depth estimation by illuminating the scene with a flickering light and capturing an image using a rolling shutter camera. The flickering light induces stripe patterns in the rolling shutter image, which encode metric depth cues and scene geometry.

The method begins by capturing an image with a rolling shutter sensor under illumination from a flickering light source. A CNN is then trained to decompose the captured image into two components: the image under ambient lighting, I0I_0, and IrollI_{roll}, which contains the rolling-shutter-induced pattern encoding depth and geometry. An existing method is used to extract an affine-invariant depth map using I0I_0 as input. A separate ViT-based transformer then takes the relative depth map and IrollI_{roll} as input to predict the global scale and shift, which are applied to the relative depth map from Marigold to produce the final metric depth map. The work claims benefits in situations where image metadata is unavailable or incomplete.

Strengths and weaknesses

Strengths

  1. The forward model for simulating rolling-shutter-based image formation while accounting for depth is very interesting and insightful.
  2. The idea of using rolling shutter for depth cues in combination with a strong diffusion prior is quite fresh and novel.
  3. The paper includes a hardware demonstration by actually building a flickering LED setup, which is a commendable effort.
  4. The dataset curation is valuable.
  5. A low-cost hardware solution for metric depth estimation would be highly valuable.

Weaknesses

  1. The work is missing several relevant citations, and the related work section could be written more thoroughly for completeness. Monocular metric depth estimation using a combination of sensing cues and foundation models has prior work [1], [2], [3] that should be referenced. Other suggested citations are also mentioned below in the text block.

  2. The Lambertian assumption does not always hold in practice. And since the model is trained with the specular forward model, there is a slight performance degradation when incorporating specular reflectance at test time.

  3. The contribution of the stripe pattern and geometry term, SrollS_{roll} in the paper, diminishes as 1/d21/d^2. This may lead to a weaker signal for far-away depths. Strong sunlight in outdoor settings could also easily diminish the intensity of the flickering flashlight.

  4. The method requires setting up custom hardware, making it slightly less amenable to outdoor deployment.

  5. The method should be compared not only with zero-shot metric depth estimation methods, but also with methods that incorporate external metric depth cues and optimize global scale and shift, such as Marigold-DC. This would be a fairer comparison, as the proposed method belongs to a class of approaches that rely on pretrained monocular depth estimators and incorporate metric depth cues through additional sensing. Since Marigold-DC is essentially sparse depth completion, it would be useful to compare against some version of it, perhaps on NYU-v2, to evaluate how much better the proposed sensing strategy is compared to using LiDAR/RADAR systems that provide sparse ground-truth depth.

  6. Marigold may produce relative depths that are not exactly correct at regional or per-pixel levels. Since the relative depth estimates can also depend on the initial noise vector, this issue should be addressed in the paper.

  7. Figure 1 is somewhat confusing in terms of clearly indicating what is happening in the actual method.

Minor Writing Typos Line 288: There is an extra “-” after “LiDAR, radar, etc.”

Suggested citations:

[1] M. Viola, K. Qu, N. Metzger, B. Ke, A. Becker, K. Schindler, and A. Obukhov, “Marigold-DC: Zero-Shot Monocular Depth Completion with Guided Diffusion,” ICCV, 2025.

[2] J. Gregorek and L. Nalpantidis, “SteeredMarigold: Steering Diffusion Towards Depth Completion of Largely Incomplete Depth Maps,” ICRA, 2025.

[3] C. Talegaonkar, N. Gandudi Suresh, Z. Novack, Y. Belhe, P. Nagasamudra, and N. Antipa, “Repurposing Marigold for Zero-Shot Metric Depth Estimation via Defocus Blur Cues,” NeurIPS, 2025.

[4] M. O’Toole, S. Achar, S. G. Narasimhan, and K. N. Kutulakos, “Homogeneous Codes for Energy-Efficient Illumination and Imaging,” ACM TOG / SIGGRAPH, 2015.

[4] S. Achar, J. R. Bartels, W. L. Whittaker, K. N. Kutulakos, and S. G. Narasimhan, “Epipolar Time-of-Flight Imaging,” ACM TOG / SIGGRAPH, 2017.

[5] T. Ueda, H. Kubo, S. Jayasuriya, T. Funatomi, and Y. Mukaigawa, “Slope Disparity Gating using a Synchronized Projector-Camera System,” ICCP, 2019.

[6] E. Ringaby and P.-E. Forssén, “Scan Rectification for Structured Light Range Sensors with Rolling Shutters,” ICCV Workshops, 2011.

[7] D. Guo and R. Tan, “Rolling in the Deep: Exploiting Rolling Shutter Effect Against Stereo Depth Estimation in Drones,” DroNet, 2025.

Questions

My questions are mentioned in the weaknesses, specifically points 2., 5., and 7. A broader question for the authors, can you provide information on how do you plan to restructure the paper once you add in related work in the main paper and discuss the additional related work?

Limitations

Point 6 in the weakness section should be discussed more thoroughly in the paper. The paper would benefit from adding visual experiments or validation evaluating scenarios where Marigold has higher errors in its predicted depth.

It may also be beneficial, as future work, to explore an extension that predicts uncertainty maps for the rolling-shutter image, allowing the model to use the uncertainty map to discard unreliable depth predictions from specular regions. This might also be possible by adjusting the attention masks of the pre-trained ViT model, and could be worth evaluating. This is not necessary for the rebuttal, but would be a useful addition for the final draft or future work discussion.

Final justification

The rebuttal addresses most of my concerns, and I am increasing my score to 5. While the method has some weaknesses, the results are strong within the assumed setting. The idea of leveraging rolling-shutter-based metric depth cues in conjunction with monocular depth priors is quite novel. Although comparisons with active depth sensing approaches are absent, I do not believe this diminishes the paper's contribution: demonstrating that a relatively simple, consumer-grade setup — flash flicker combined with rolling shutter — can significantly improve monocular metric depth estimation is compelling. Compared to active sensing approaches such as structured light, which require expensive hardware, camera–projector calibration, and considerably higher cost, this represents a practical and innovative alternative.

Formatting concerns

The related work section should not be in the supplement. The work is also missing couple of citations.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the valuable feedback, suggestions, and highly relevant related citations. We are pleased to engage in a constructive discussion and address all weaknesses (W) and limitations (L) below. Since two different papers in the reviewer's comments are both cited as [4], we refer to them as [4a] and [4b] for clarity.

(W1) Add Citations and Restructure the Related work

We thank the reviewer for pointing us to these recent and highly relevant works. Following the reviewer's suggestions, we will expand and restructure the Related Work section as follows:

  • Depth Estimation with Zero-Shot Transferability. We will retain the current discussion.
  • Depth Estimation with Physical Cues. We will expand this subsection. The current version focuses primarily on focus/defocus and structured-light methods. Following the reviewer's suggestions, we will cover recent approaches that combine physical or external sensing cues with affine-invariant models, such as Marigold, including [1]–[3]. We will clarify how Roll2Depth differs in both the source of its metric cue and the way that cue is acquired.
  • Rolling Shutter in Imaging and Sensing. Motivated by the reviewer's suggested references, we will add a dedicated subsection on the role of rolling shutter in imaging and sensing. Prior work has treated rolling-shutter artifacts as interference to be suppressed [6], or exploited them as an attack vector against vision systems [7]. Another line of computational imaging research, highlighted by the reviewer, constructively combines rolling-shutter exposure with synchronized illumination to enable epipolar and disparity gating for 3D reconstruction [4a], ToF imaging [4b], and selective imaging [5]. In contrast, Roll2Depth uses rolling shutter and flickering illumination as a single-shot temporal demultiplexer for depth cues. Note that Roll2Depth does not require synchronization between the camera and light source, thereby keeping the hardware overhead low.

(W2/3 & L2) Extension of Uncertainty-Aware Affine-to-Metric Transformation

We appreciate the reviewer's insightful comment. The idea of using an uncertainty map to suppress unreliable rolling-shutter shading could be highly valuable. In particular, the reliability of the extracted physical cue may degrade under challenging conditions, such as non-Lambertian reflectance, e.g., specular regions, or weak flickering signals due to attenuation and strong outdoor sunlight. An intuitive approach is to add an uncertainty head to the physical cue extractor, trained from cue-extraction errors under randomized non-Lambertian reflectance. The predicted per-pixel uncertainty could then reweight ViT tokens or attention, downweighting unreliable regions and improving the robustness of global scale and shift estimation. We will discuss this promising direction as future work in the revised paper.

(W4/5) Marigold-DC Comparison: Positioning Roll2Depth in Hardware-Assisted Depth Estimation

We thank the reviewer for pointing out Marigold-DC, a representative approach that leverages dedicated depth sensors such as LiDAR to optimize global scale and shift. Powered by stronger supervision from these sensors, Marigold-DC serves as an upper-bound reference for Roll2Depth, as also verified by our new experiment suggested by the reviewer. Roll2Depth, in contrast, extracts metric information from a weaker yet low-cost photometric cue induced by a flickering light source. Compared with existing hardware-assisted works relying on dedicated sensors like LiDAR, ToF, or RGB-D sensors, Roll2Depth occupies a practical middle ground: it introduces minimal hardware overhead but effectively improves metric depth estimation, making it suitable for cost-sensitive platforms such as smartphones, robot vacuums, and consumer-grade drones. To modulate an existing light source, Roll2Depth only requires a commodity MOSFET-based switching circuit. We will include this comparison in our final version to clarify the trade-off between depth accuracy and sensing cost.

(W6 & L1) Impact of Marigold Stochasticity and Local Errors

As the reviewer correctly pointed out, Marigold's stochastic inference may produce different dreld_{rel} predictions under different initial noise vectors. Following Marigold's test-time ensemble strategy, we evaluated using an aggregated dreld_{rel} by taking the pixel-wise median of 10 predictions from different noise initializations. As shown in Table R8, the results with and without ensembling are comparable, suggesting that Marigold's stochastic variations do not substantially change the final metric depth estimation results. We will incorporate the above results in the final version.

As mentioned by the reviewer, Marigold may contain regional or pixel-level depth errors. Since Roll2Depth currently applies only a global scale and shift, Marigold's local errors would propagate to the final prediction. We will add discussion and visual comparisons on challenging samples as suggested, showing which Marigold errors are reduced by ensemble and which remain in Roll2Depth's output. Finally, as the research field continues to advance, we hope that Roll2Depth would also benefit from stronger affine-invariant depth backbones in the future.

Table R8: Zero-shot metric depth accuracy (AbsRel$\downarrow$ and RMSE$\downarrow$) with and without Marigold test-time ensembling.

Method SUN RGB-D iBims DIODE HyperSim Scene 1 Scene 2
w/o ensemble 0.171 / 0.318 0.094 / 0.405 0.147 / 0.595 0.266 / 4.556 2.426 / 1.146 0.405 / 0.887
with ensemble 0.171 / 0.317 0.094 / 0.406 0.147 / 0.593 0.264 / 4.540 2.460 / 1.183 0.407 / 0.885

(W7) Refine Figure 1 to Better Present High-Level Workflow

Current Figure 1 is a conceptual overview, emphasizing the key insight that rolling-shutter cameras convert flickering illumination into spatial stripe patterns that provide physical depth cues. However, we agree with the reviewer that it could be improved to more clearly indicate the actual processing flow of Roll2Depth. In our final version, we will update Figure 1 to clarify the high-level workflow of Roll2Depth, including how it uses the extracted rolling-shutter shading to estimate the global scale ss and shift tt, which transform the affine-invariant depth prediction into metric depth.

Fixing Typo in Line 288

We thank the reviewer for catching this typo and will correct the extra "-" in the final version.

Reviewer tK9v · CommentOpenReview ↗

I thank the authors for the response. The authors indicate that they will add the relevant citations, improve Figure 1, and discuss the positioning of their work w.r.t. Marigold-DC, which is helpful. The provided response resolves most of my concerns.

Table R8 also addresses my concerns about the effect of Marigold -errors. It seems that on the standard datasets the local errors do not have a significant impact based on the quantitative results. This finding supports the proposed approach, and should be added to the paper.

However, the conceptual weakness still remains, that the proposed method can only alter global scaling and shift based on the physical cues from rolling shutter measurements, and is not robust to inaccuracies in the Marigold prediction. This should still be mentioned in the paper as a limitation.

Authors · CommentOpenReview ↗

We sincerely thank the reviewer for the valuable feedback. We appreciate the reviewer's recognition that our responses address most of the concerns.

We would like to confirm that all revisions and additional discussions promised in our rebuttal, including the ablation results on Marigold test-time ensembling as well as the explicit discussion of the limitation regarding sensitivity to errors in Marigold predictions, will be incorporated into the final version.

Reviewer RZqSOpenReview ↗
Rating
3/6
Confidence
4/5
Quality
2/4
Clarity
3/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper proposes an interesting hardware-assisted idea for metric depth estimation. The idea is to use the rolling shutter stripe pattern response to a co-located flickering source as an active metric depth cue, extract it with a learned network, then regress global scale and shift to lift an affine-invariant Marigold depth into metric. The results show that the proposed method outperforms all state-of-the-art passive baselines and produces a more accurate metric depth.

Strengths and weaknesses

The proposed idea is novel and interesting to use a rolling shutter plus flicker as a single-shot demultiplexer to obtain a metric depth cue; to the best of my knowledge I haven't seen this elsewhere. I also appreciate the authors exploiting the physics of off-the-shelf cameras instead of relying only on camera metadata. It’s also useful to see a bunch of ablation studies in the paper and the appendix. But I’m concerned with the rather simplistic theoretical part of the paper and the experimental evidence the paper presents.

Please see the main weaknesses below:

  1. I think it's misleading that first, the proposed method states that the rolling shutter image encodes physical cue, and second, the paper compares against passive baselines. The depth-related signal comes from the active flickering light with irradiance falling off with distance captured by the rolling shutter camera. This is really an active illumination method that uses a rolling shutter as a demodulation mechanism.
  2. Equations 3 and 4 show that rolling shutter shading is inversely proportional to depth squared and seems to be too simplistic. Does this mean it can only apply to very controlled scenarios, such as scenes where most are Lambertian surfaces with known albedo and normal effects already divided out?
  3. The paper states multiple times that the rolling shutter depth cue is physically grounded but the framework extracts it with a network and then feeds it into another affine-to-metric transformation network. How can we know that the network is not hallucinating? I think to support the physically grounded claim, the authors should include at least some analytical or semi-analytical formulations. For example, the authors can compare the learned scale estimate against the output of a simple physics-based estimator.
  4. In the ablation study results, it seems that the model can benefit from training/test distribution differences or synthetic cue priors? To isolate components I would expect a stronger experiment to train matched models with and without active flickering illumination and also test on randomized vs physically incorrect stripe patterns and see if they degrade performance. 

Addressing the points above would help me better understand the effectiveness of the proposed method.

Questions
  1. What exactly must be calibrated per device for P'/P?
  2. How can we know that the networks you use to extract the rolling shutter cue are not hallucinating?
  3. The bright and dark bands fall on different rows, so the bright-minus-dark separation assumes depth, albedo, and normal are constant over one band period. How does this hold on high-frequency geometry at the band scale?
Limitations

The authors should also state the limitations related to the rolling shutter spatial and temporal frequency. Does that limit the scenes you can capture depth cues from?

Formatting concerns

The paper follows the NeurIPS formatting and anonymity requirements.

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the valuable feedback and suggestions. We are pleased to engage in a constructive discussion and address all weaknesses (W), questions (Q), and limitations (L) below.

(W1) Clarification of Rolling Shutter as a Single-Shot Demultiplexer

We appreciate the reviewer's insightful comment. As the reviewer noted, our original statement that “the rolling shutter image encodes physical cues” could be misleading, as it may imply that rolling-shutter images inherently contain metric information without active illumination. In our final version, we would like to clarify that Roll2Depth leverages rolling shutter and flickering light source as a single-shot demultiplexer to extract metric depth cues encoded by active illumination. This single-shot extraction avoids the motion artifacts potentially introduced by multi-frame acquisition. We will revise the corresponding descriptions, especially the positioning of rolling shutter and active illumination, throughout the paper accordingly.

(W2) Impact of Lambertian Assumption in Equations 3 and 4

As the reviewer points out, the forward model in Eqs. (3) and (4) assumes Lambertian reflection. Real scenes may exhibit non-Lambertian effects, such as specular reflections, which may deviate from this simplified model. Roll2Depth effectively handles non-Lambertian deviations through its affine-to-metric transformation network, which regresses global scale and shift by aggregating information across all pixels, making it robust to local reflectance variations. Two pieces of experimental evidence demonstrate its robustness:

  1. First, Appendix C explicitly evaluates robustness to non-Lambertian reflections by adding unseen Blinn–Phong specular components at test time (shown in Table 7). Despite being trained with Lambertian cues, Roll2Depth degrades only gradually as specular strength increases and remains competitive even under strong non-Lambertian perturbations, demonstrating robustness to deviations from the Lambertian assumption.
  2. Second, our real-world evaluation in §4.2 is conducted in naturally captured indoor scenes containing strongly non-Lambertian surfaces, such as metallic objects and TV screens. Roll2Depth still achieves the best or competitive performance in Table 2 despite non-Lambertian deviations.

We appreciate the reviewer's valuable comment. In our final version, we will clarify that Eqs. (3)–(4) describe the dominant physical relationship, while the learned affine-to-metric transformation handles practical deviations from this simplified model.

(W3 & Q2) Validation of the Physical Grounding of Extracted Signals

As the reviewer noted, the intermediate signal output by the extraction network may potentially be an arbitrary representation rather than the intended physically grounded cue. We address this concern in two aspects.

  1. We clarify that the extraction network is constrained to recover a physically grounded signal rather than an unconstrained representation. It is trained separately with reconstruction loss in Eq. (5) to recover the clean image I0I_0 with Iroll=I−I0I_{roll}=I-I_0 computed deterministically. The extractor is then frozen when training the subsequent affine-to-metric module, preventing the downstream objective from adapting the extracted signal into a task-specific latent representation. We further evaluate the fidelity of the extracted I0I_0 with the ground-truth clean image. As shown in Table R5, the extracted I0I_0​ achieves higher PSNR/SSIM than the original input II across datasets, providing additional evidence that the extraction network recovers the intended physical decomposition. We will clarify the stage-wise training procedure in §3.

    Table R5. Fidelity of physical cue extraction. Each cell reports PSNR$\uparrow$ / SSIM$\uparrow$.

    Method SUN RGB-D iBims-1 DIODE Indoor HyperSim
    Before Extraction 24.959 / 0.9993 30.658 / 0.9998 29.794 / 0.9993 29.443 / 0.9993
    Extracted by Roll2Depth 30.595 / 0.9998 32.299 / 0.9999 30.168 / 0.9995 30.530 / 0.9996
  2. Following the reviewer's suggestion, we further compare the learned affine-to-metric transformation against a simple physics-based estimator. It first derives a coarse metric depth dcoarsed_{coarse} from the inverse-square law and then estimates the scale ss and shift tt by fitting s⋅dcoarse+ts \cdot d_{coarse}+t to dreld_{rel}. As shown in Table R6, the physics-based estimator already achieves meaningful metric-depth accuracy, demonstrating that the extraction network recovers the intended SrollnormS_{roll}^{norm} rather than a hallucinated representation. Meanwhile, compared with the simple physics-based estimator, the learned estimator achieves better performance by learning a more robust affine-to-metric mapping from the extracted physical signal and visual context.

    Table R6. Comparison between the physics-based and learned affine-to-metric estimators. Each cell reports AbsRel$\downarrow$ / RMSE$\downarrow$.

    Method SUN RGB-D iBims DIODE HyperSim
    Physics-based estimator 0.326 / 0.665 0.350 / 1.348 0.547 / 2.081 0.362 / 3.996
    Learned estimator (Roll2Depth) 0.171 / 0.317 0.094 / 0.406 0.147 / 0.593 0.264 / 4.540

(W4) Ablation with Physically Incorrect Stripes

Following the reviewer's suggestion, we conducted a matched intervention study to isolate the contribution of the physically valid cue. Specifically, we trained matched models with and without active flickering illumination and tested the models using both correct and physically incorrect (randomized) stripe patterns. The results are shown in Table R7. Only physically correct cues consistently improve depth estimation, whereas removing or corrupting the cue degrades performance. This confirms that Roll2Depth relies on the correct cue-depth relationship to estimate accurate metric depth.

Table R7. Matched training and test-time intervention study. Each cell reports AbsRel$\downarrow$ / RMSE$\downarrow$.

Training Setting Test-time Condition SUN RGB-D DIODE Indoor HyperSim iBims-1
Without cue No cue 1.604 / 2.302 0.712 / 1.843 0.520 / 5.436 0.624 / 1.465
With cue Cue removed 0.405 / 0.949 0.480 / 2.239 0.739 / 8.268 0.554 / 2.237
With cue Physically incorrect stripes 0.392 / 0.727 0.860 / 2.637 0.761 / 6.662 0.504 / 1.592
With cue Correct 0.171 / 0.317 0.147 / 0.593 0.264 / 4.540 0.094 / 0.406

(Q1) Clarification on P′/PP'/P Calibration

The required calibration is a power factor kk, which represents the intensity ratio between the flickering source and ambient illumination. It is used to normalize the shading SrollnormS_{roll}^{norm}, such that it approximately follows the inverse-square relationship with absolute depth. This factor can be obtained through calibrated camera measurements (e.g., under fixed or normalized exposure) or, alternatively, measured directly using photodiodes in practical deployments.

(Q3 & L1) Clarify the impact of high-frequency geometry

We clarify that Roll2Depth does not rely on bright-minus-dark subtraction for extracting SrollnormS_{roll}^{norm}. Instead, SrollnormS_{roll}^{norm} is extracted by our physical cue extraction module. The affine-to-metric transformation network then aggregates SrollnormS_{roll}^{norm} to estimate the global scale ss and shift tt. Therefore, local errors in SrollnormS_{roll}^{norm}, such as those caused by high-frequency geometry, have limited influence on the global scalar estimation. Relevant evidence comes from our real-world experiments, which include scenes with high-frequency geometry, such as fine-striped carpets, where Roll2Depth still achieves adequate depth estimation. We will incorporate the above discussion in our final version.

Authors · CommentOpenReview ↗

Dear Reviewer RZqS,

Thank you for your valuable and responsible review, which has been very inspiring for us.

We would appreciate it if you could let us know whether our response has addressed your concerns. We look forward to further discussion with you.

Best,
Authors

Reviewer LA7qOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
4/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper proposes a system to compute the highly non-linear inverse problem of calculating depth from the interaction of a flickering light and the striped pattern of a rolling shutter camera. The core of the system consists of two networks: one that learns to separate the image under standard illumination I0I_0 from the superimposed IrollI_{roll} patterns, and a second that uses the extracted striped shadow information SrollS_{roll} to compute the global scale factor ss and shift tt to metrically correct the depth estimated by a non-metric depth estimation method (i.e., Marigold). The extra information to refine depth comes from the dependency of SrollS_{roll} on depth, considering that the source of the flickering light is placed close to the rolling shutter camera. The approach is tested on four common RGB-D benchmarks, synthetically adapted for the task, and a new real dataset with actual flickering light as a final test of the effectiveness of the method.

Strengths and weaknesses

Strengths:

  • The idea of using cheap hardware to refine the already good non-metric depth estimation by leveraging active light is clever and very useful. I agree with the authors that this system could be applied to a good number of use cases, although the outdoor efficacy has to be proven.
  • The paper is well structured, easy to follow and both the methodological section and the validation setup are convincing and thoroughly detailed.
  • The adaptation of the bin-based regression module increases robustness (acting as a form of regularization) and effectively limits output volatility.
  • The results on common benchmark datasets are compelling.
    Weaknesses:
  • My first comment is not really a weakness, but more a consideration on the paper positioning: the core of the method relies on the extra information that is available from an active light source that is placed in close proximity to the camera, meaning that the illumination of the scene when the active source is on is dependent on the same depth dd of the camera looking at the scene. The fact that the framework uses a rolling shutter to extract this information is just a convenience that is justified by the availability of rolling shutter cameras, and not by the physics. In other words, using a global shutter and taking two frames, one with the light on and one with the light off, should provide the same information to the networks (instead of stripes, the system would extract a differential image, e.g., I0+IonI_0 + I_{on}), but the rest of the system would probably be identical. Only the loss in Eq. 5 (the frequency-based term) would be considerably different. Given that, I would not frame the paper as an example of the use of "rolling shutter to compute depth", but an application of active light to compute depth.
  • The comparison misses some recent relevant zero-shot metric depth foundation models, such as Metric3D-v2 and Depth Any Camera.
  • Given that the system relies on active lighting, the work really needs some kind of efficacy curve evaluating how performance degrades under high ambient light or at longer distances where the active signal attenuates, which is vital for real-world deployment. There should be no difficulty in experimenting with different relative intensities and computing a curve of efficacy for the framework.
  • The frequency term in Eq. 5 should be ablated too, to understand why it is there. Or at least, a comment should be given on why such a term was deemed necessary.
Questions

Questions:

  1. Light Intensity and Distance Thresholds: Since the framework relies on cleanly isolating the active light pattern (SrollS_{roll}) , how does it handle very bright ambient light or longer distances where the 1/d21/d^2 signal drops off sharply? Can you provide a quick efficacy curve showing where the system starts to struggle?
  2. Ablation of Frequency Loss: Could you show an ablation isolating the vertical 1D DFT component (Lext\mathcal{L}_{ext}) from a standard spatial L2L_2 loss? This would help clarify exactly how much the frequency-domain design helps the extraction network.
  3. Physics vs. Framing Clarification: To make sure I understand the physics right: the absolute metric scale is fundamentally provided by the collocated light source , while the rolling shutter is just a convenient single-frame vehicle to avoid motion artifacts? A brief comment in the text confirming this would clear up any confusion about the framing.
  4. Missing Baselines: Any chance you could discuss or compare your results against newer zero-shot metric depth foundation models like Metric3D-v2 or Depth Any Camera (DAC)?

Score Adjustment Criteria:

  • I would gladly upgrade my score if the authors could provide an efficacy curve regarding the lighting/distance thresholds (Question 1), provide text clarifications regarding the active light framing (Question 3), and ideally present a quick ablation on the frequency loss (Question 2).
  • To decrease score: My score might go down if the rebuttal shows that the extraction module is highly fragile under standard indoor ambient light variations.
Limitations

Yes, the authors are upfront about the fact that their work is currently limited to indoor settings and that moving outdoors would require modeling a more complex sensing range and directional lighting. However, even within the indoor scope, there are two critical limitations missing from their discussion that they should address:

  • Ambient Light / SNR Constraints: The framework assumes it can cleanly isolate the stripe patterns. In real-world indoor rooms with bright ambient light (like sitting right next to a sunny window), the signal-to-noise ratio of the active flickering light will drop significantly, which might cause the extraction module to fail.
  • Dependency on External Pipelines: To normalize the rolling shutter cue, the system relies entirely on off-the-shelf external models to predict albedo and surface normals beforehand. Any failure or severe noise in those upstream estimators will directly corrupt the metric scale prediction downstream.

Suggestion: The authors should expand Section 5 to briefly acknowledge these ambient lighting limits and the cascading risks of relying on external albedo/normal estimators.

Final justification

In my initial review, I noted several missing elements needed for a complete evaluation: efficacy curves under varying distances and ambient light, an ablation of the frequency loss, and comparisons against recent zero-shot metric depth baselines. I also requested that the authors reframe the narrative to clarify that the absolute metric scale originates from the active light source, rather than the rolling shutter mechanism itself. The authors provided an excellent rebuttal that successfully addressed all of my concerns. The additional experiments and tables clearly demonstrate the method's robustness across reasonable distances and SNR variations, justify the use of the frequency term, and show strong performance against modern baselines. Because the authors have provided the requested data and committed to transparently including these limitations and framing adjustments in the final manuscript, I am raising my score to recommend acceptance.

Formatting concerns

None

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the valuable feedback and suggestions. We are pleased to engage in a constructive discussion and address all weaknesses (W), questions (Q), and limitations (L) below.

(W1 & Q3) Reframing the Role of Rolling Shutter

We appreciate the reviewer's insightful comment, which helps disentangle Roll2Depth's metric cue source from its capture mechanism. As the reviewer correctly noted, the metric scale in Roll2Depth originates from the collocated light source. Capitalizing on this physics, Roll2Depth exploits the combination of rolling shutter and flickering illumination to encode light variations into spatial patterns, enabling single-frame extraction of metric depth cues while avoiding the motion artifacts introduced by multi-frame acquisition. Accordingly, in our final version, we will revise the abstract and introduction to clarify that Roll2Depth leverages rolling shutter to capture metric cues encoded by active flicker, rather than as the sole source of metric information.

(W2 & Q4) Additional Baseline Comparisons

As suggested, we compare Roll2Depth with Metric3D-v2 and Depth Any Camera (DAC) in Table R1. The HyperSim dataset is excluded since it has been used for training these methods. Roll2Depth demonstrates strong and consistent zero-shot metric-depth performance across the three remaining benchmarks and our real-world scenes, showing its effectiveness.

Table R1. Zero-shot metric depth estimation results on standard and our collected benchmarks. Each cell reports AbsRel↓, RMSE↓, and δ1↑.

Method SUN RGB-D iBims-1 DIODE Scene 1 Scene 2
Metric3D v2 0.412 / 0.490 / 0.595 0.160 / 0.521 / 0.687 0.252 / 1.440 / 0.816 3.017 / 1.524 / 0.512 0.464 / 1.259 / 0.242
DAC 0.254 / 0.864 / 0.569 0.303 / 1.566 / 0.231 0.348 / 1.485 / 0.410 1.875 / 1.234 / 0.538 0.489 / 1.769 / 0.180
Roll2Depth 0.171 / 0.317 / 0.867 0.094 / 0.406 / 0.921 0.147 / 0.593 / 0.848 2.460 / 1.183 / 0.629 0.407 / 0.985 / 0.769

(W3 & Q1 & L1) Efficacy Curves under Distance and Ambient Light Variations

Following the reviewer's suggestion, we provide efficacy evaluations for Roll2Depth under varying distance and ambient light. As shown in Table R2 and R3, Roll2Depth maintains relatively stable performance from 1 m to 10 m, with AbsRel ranging from 0.170 to 0.241 and only slight degradation with distance. Performance degrades mainly in the closest distance bin, which is also challenging for other monocular metric depth methods due to the increased sensitivity to depth errors. We further evaluate the impact of ambient light by varying the active-to-ambient SNR, which jointly captures the strength of the active signal and ambient light. Across −21 to −8 dB, AbsRel ranges from 0.331 to 0.515 without exhibiting a sharp failure point. (Here, a lower SNR means stronger ambient light. For reference, an SNR of −20 dB roughly corresponds to a 10W LED under 2,000 lux ambient light.) The relatively stable performance across distance and SNR is enabled by Roll2Depth's progressive physical cue extraction network, which can isolate subtle stripe patterns even when the active signal is attenuated. As suggested by the reviewer, we will clarify this distance and ambient light limitation in Section 5 in our final version.

Table R2. Efficacy evaluation under varying sensing distances.

Distance 0–1 m 1–2 m 2–3 m 3–4 m 4–5 m 5–6 m 6–7 m 7–8 m 8–9 m 9–10 m
AbsRel 1.364 0.170 0.221 0.174 0.181 0.187 0.190 0.241 0.199 0.181

Table R3. Efficacy evaluation under varying active-to-ambient SNR. Lower SNR indicates stronger ambient light relative to the active signal.

SNR -21dB -20dB -19dB -18dB -17dB -16dB -15dB -14dB -13dB -12dB -11dB -10dB -9dB -8dB
AbsRel 0.336 0.389 0.365 0.345 0.331 0.409 0.507 0.470 0.444 0.515 0.363 0.349 0.439 0.448

(W4 & Q2) Ablation of the Frequency Term in Eq.5

Following the reviewer's suggestion, we ablate the frequency term in Eq. 5 to isolate its contribution. As shown in Table R4, removing the frequency term leads to noticeable performance degradation. This is because rolling-shutter stripes exhibit row-wise periodic structures along the vertical direction. Such structured patterns can be effectively characterized by a 1D Fourier transform along the vertical axis, where the frequency loss complements the spatial reconstruction loss by further penalizing residual or distorted stripe components. This improves the reliability of the extracted physical cue, leading to more accurate metric depth estimation.

Table R4. Ablation of frequency loss.

Setting Scene 1 (AbsRel↓) Scene 1 (RMSE↓) Scene 2 (AbsRel↓) Scene 2 (RMSE↓)
w/o frequency term 4.489 2.177 0.625 1.090
with frequency term 2.460 1.183 0.407 0.885

(L2) Dependency on External Pipelines

We appreciate the reviewer for this valuable comment. In our final version, we will discuss the limitation of dependency on external pipelines and potential mitigation strategies, such as incorporating an uncertainty map to reduce the impact of unreliable outputs from external pipelines, in Section 5.

Authors · CommentOpenReview ↗

Dear Reviewer LA7q,

Thank you for your valuable and responsible review, which has been very inspiring for us.

We would appreciate it if you could let us know whether our response has addressed your concerns. We look forward to further discussion with you.

Best,
Authors

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?