What Do EEG Representations Reveal? Multiview Neural Representations to Demystify the EEG-Visual Alignment
Salini Yadav, Taveena Lotey, Pravendra Singh, Partha Pratim Roy
NeurIPS 2026
TL;DR. A multiview EEG encoding framework that enables zero-shot visual decoding and generalizes across subjects and recording sessions.
Abstract. Zero-shot visual decoding from electroencephalography (EEG) aims to infer visual semantics from non-invasive neural recordings, but remains challenging due to the low signal-to-noise ratio, non-stationarity, and limited spatial resolution of EEG. Existing EEG–vision alignment methods typically model the temporal, spectral, and spatial structure of EEG separately or only partially, leaving their complementary roles in visual perception underexploited. We introduce a unified multiview EEG representation learning framework for aligning brain responses with visual semantic embeddings. Our method builds an EEG encoder that jointly models three complementary views: input-conditioned state-space temporal dynamics, learnable wavelet-based spectral decomposition for sample-adaptive frequency modeling, and attention-modulated graph learning for structured electrode interactions. The resulting multiview EEG embeddings are fused and aligned with pretrained visual representations in a shared semantic space using contrastive learning with EEG-specific regularization, enabling 200-way zero-shot visual classification. Experiments on THINGS-EEG benchmark show that our method achieves state-of-the-art performance, with 54.8% Top-1 and 85.6% Top-5 accuracy in the within-subject setting and 15.3% Top-1 and 45.4% Top-5 accuracy in the cross-subject setting. We further present the systematic evaluation of cross-session zero-shot EEG–image semantic decoding/retrieval, achieving 40.8% Top-1 and 78.0% Top-5 accuracy. These results suggest that explicitly modeling multiview neural structure improves both semantic alignment and generalization in EEG-based visual decoding.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:46 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper proposed a new EEG representation learning framework to align brain response with visual semantic embeddings. The reviewers agree that explicitly modeling temporal, spectral, and spatial EEG structure is reasonable, and they appreciate the inclusion of within-subject, cross-subject, and cross-session evaluations. However, several serious reservations currently preclude publication.
First, the state-of-the-art and novelty positioning appears incomplete. One reviewer identifies several contemporary methods that are absent from the comparison and reportedly achieve substantially higher THINGS-EEG accuracy. Even without consideration of missing references, the method is not stably outperform the baselines reported in this paper. Second, the experiments do not establish that the multiview decomposition is the source of the gain. The contribution from architecture, capacity, and loss contributions are confounded. This also undermines claims of lower variance and robust generalization, especially because cross-subject improvements are not consistent across subjects and cross-session evaluation includes only one baseline. Third, several interpretive claims exceed the evidence. Near-zero cross-view cosine/CKA after projection and normalization does not demonstrate distinct physical mechanisms. Alignment only to the final CLIP layer is difficult to reconcile with the paper's multi-scale visual motivation, and the RCR objective may suppress structured repetition/adaptation effects rather than only noise.
Before the rebuttal, I encouraged the authors to correct possible factual errors, improve the clarification, carefully check the potentially missing references and results, as well as fairly justify their contributions and revise possible overclaims. During the rebuttal, The authors resolved the most serious methodological concern by adding parameter-matched single-view controls and applying the same CPCA/RCR losses to a strong baseline, showing that the improvement is not explained by capacity or regularization alone. The authors also added multi-seed evaluation, all-subject ablations, statistical tests, and a broader cross-session comparison. Several related-work objections were shown to involve non-comparable modalities or contemporaneous work and should not be used as grounds for rejection. The authors appropriately narrowed the SOTA, cross-subject, cross-view, and neurobiological claims.
However, it doesn't eliminate all reasons for rejection. The reviewers and the authors had some discussion during the discussion period. The cross-session Top-1 improvement over the strongest baseline is limited and not statistically significant; low cross-view cosine/CKA supports only less-aligned learned subspaces, not physical independence or strong complementarity; and the fixed-wavelet control that would further separate learned spectral modeling from architectural decorrelation was not provided. But overall the reviewers are all lean towards acceptance.
The decision was tough. Yet the sound empirical contribution, the new attribution controls, and the useful cross-session protocol slightly outweigh the remaining concerns. So I would recommend an acceptance given the belief that the authors can revise the title, tune down there claims to prevent any overstates, and adding more references in the final version.
Final justification
The paper has clear strengths, including a well-motivated multiview EEG encoder, strong within-subject results, and useful cross-session evaluation. Important concerns nevertheless remain. On balance, I recommend acceptance, with the expectation that the final version adopts the narrower claims, revises the title and abstract, accurately presents prior work, and incorporates the new controls and limitations from the discussion.
Read meta-review
Meta-review
The paper proposed a new EEG representation learning framework to align brain response with visual semantic embeddings. The reviewers agree that explicitly modeling temporal, spectral, and spatial EEG structure is reasonable, and they appreciate the inclusion of within-subject, cross-subject, and cross-session evaluations. However, several serious reservations currently preclude publication.
First, the state-of-the-art and novelty positioning appears incomplete. One reviewer identifies several contemporary methods that are absent from the comparison and reportedly achieve substantially higher THINGS-EEG accuracy. Even without consideration of missing references, the method is not stably outperform the baselines reported in this paper. Second, the experiments do not establish that the multiview decomposition is the source of the gain. The contribution from architecture, capacity, and loss contributions are confounded. This also undermines claims of lower variance and robust generalization, especially because cross-subject improvements are not consistent across subjects and cross-session evaluation includes only one baseline. Third, several interpretive claims exceed the evidence. Near-zero cross-view cosine/CKA after projection and normalization does not demonstrate distinct physical mechanisms. Alignment only to the final CLIP layer is difficult to reconcile with the paper's multi-scale visual motivation, and the RCR objective may suppress structured repetition/adaptation effects rather than only noise.
Before the rebuttal, I encouraged the authors to correct possible factual errors, improve the clarification, carefully check the potentially missing references and results, as well as fairly justify their contributions and revise possible overclaims. During the rebuttal, The authors resolved the most serious methodological concern by adding parameter-matched single-view controls and applying the same CPCA/RCR losses to a strong baseline, showing that the improvement is not explained by capacity or regularization alone. The authors also added multi-seed evaluation, all-subject ablations, statistical tests, and a broader cross-session comparison. Several related-work objections were shown to involve non-comparable modalities or contemporaneous work and should not be used as grounds for rejection. The authors appropriately narrowed the SOTA, cross-subject, cross-view, and neurobiological claims.
However, it doesn't eliminate all reasons for rejection. The reviewers and the authors had some discussion during the discussion period. The cross-session Top-1 improvement over the strongest baseline is limited and not statistically significant; low cross-view cosine/CKA supports only less-aligned learned subspaces, not physical independence or strong complementarity; and the fixed-wavelet control that would further separate learned spectral modeling from architectural decorrelation was not provided. But overall the reviewers are all lean towards acceptance.
The decision was tough. Yet the sound empirical contribution, the new attribution controls, and the useful cross-session protocol slightly outweigh the remaining concerns. So I would recommend an acceptance given the belief that the authors can revise the title, tune down there claims to prevent any overstates, and adding more references in the final version.
Final justification
The paper has clear strengths, including a well-motivated multiview EEG encoder, strong within-subject results, and useful cross-session evaluation. Important concerns nevertheless remain. On balance, I recommend acceptance, with the expectation that the final version adopts the narrower claims, revises the title and abstract, accurately presents prior work, and incorporates the new controls and limitations from the discussion.
3 comments
Rebuttal Reply Part 2
C10: We confirm that directly comparable peer-reviewed EEG–visual decoding methods available at submission were already included. For completeness, we will discuss the newly raised concurrent/preprint/foundation works while distinguishing publication status, task, and supervision, and scope SOTA to peer-reviewed methods available at submission. We will also refine cross-subject, cross-view, and CLIP/RCR interpretations. The added controls strengthen the conclusion that the multiview gain is not explained by capacity or regularization alone.
We have carefully addressed all the points raised by the reviewers to the best of our ability, and we sincerely hope that our rebuttal will be taken into consideration when reaching a final decision. We would be truly grateful if the final decision could take into account the clarifications and responses provided in our rebuttal.
Thank you for your time and consideration.
Best regards,
Authors
Final Update to the Area Chair Following Reviewer Discussion
Dear Area Chair,
Thank you again for your careful consideration of our submission. We would like to provide a brief final update on the reviewer discussion and the additional experiments completed after our initial response to the meta-review. The discussion has progressed positively. Reviewer Jsns confirmed that there are no further concerns. Reviewer FNeP acknowledged that the main concerns had been addressed and increased the rating from 3 to 4 after reviewing the expanded cross-session evaluation and clarified ablation interpretation. Reviewer mrox also accepted the narrower cross-session novelty claim, the treatment of contemporaneous work, the RCR clarification, and the equal-loss control, which the reviewer described as a convincing test of the multiview contribution. We subsequently addressed the remaining framing concerns by revising the characterization of prior EEG foundation models, tempering the cosine/CKA interpretation, and clarifying that CLIP is used as a semantic target rather than a neurobiological model.
We also completed several important experiments:
-
A parameter-matched Single-View Transformer has slightly more parameters than our model (8.69M vs. 8.59M) but achieves 48.9%/80.1% Top-1/Top-5, compared with 54.8%/85.6% for our model.
-
Adding CPCA and RCR to ATM-DWT changes its performance only from 33.4%/61.8% to 33.2%/62.3%, showing that the improvement cannot be explained by the regularizers alone.
-
Five-seed evaluation preserves the reported performance, and the ablation analysis has been expanded from one subject to all ten subjects.
-
The cross-session comparison has been expanded from one baseline to five: NICE-EEG, NICE-SA, ATM-S, ATM-DWT, and UBP. Our method achieves the highest average performance at 40.8% Top-1 and 78.0% Top-5, compared with 39.7%/71.0% for the strongest baseline, UBP.
We have also narrowed and clarified the relevant claims. The novelty claim will refer specifically to cross-session zero-shot EEG–visual semantic decoding/retrieval; the SOTA claim will be scoped to peer-reviewed methods available at submission; cross-subject results will be presented as the highest average performance rather than uniform subject-wise superiority; and the cross-view analysis will be described as evidence of less-aligned learned subspaces rather than complete independence.
We believe that the main concerns raised in the meta-review—literature positioning, stability, architecture-versus-capacity attribution, limited cross-session evidence, and interpretation of the results—have now been substantially addressed. We respectfully ask that the final decision take into account the additional evidence, revised claims, and updated reviewer assessments.
Thank you for your time and consideration.
Best regards,
The Authors
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper studies the problem of zero-shot visual decoding from EEG. Although EEG is cheap and offers high temporal resolution, its low signal-to-noise ratio, non-stationarity, and coarse spatial resolution make semantic-level visual decoding quite challenging. The authors show that existing EEG-visual alignment methods mostly rely on holistic EEG embeddings, overlooking the complementary temporal, spectral, and spatial structures within the signal. To address this, the authors propose a unified multi-view EEG representation learning framework that, without modifying the pre-trained visual encoder, focuses on learning a stronger EEG encoder. It models three views in parallel: temporal dynamics based on a selective state space model, adaptive spectral modeling via learnable wavelet decomposition, and attention-modulated graph-convolutional spatial modeling. After fusing the three, it aligns them to the visual semantic space through contrastive learning and two EEG-specific regularizers achieving 200-way zero-shot classification. On the THINGS-EEG dataset, the method outperforms existing approaches across three settings: within-subject, cross-subject, and cross-session. The authors also introduce the first systematic benchmark for cross-session EEG-image decoding. Ablation and representation analyses further show that the three views capture complementary, non-redundant information.
Strengths and weaknesses
Strengths:
- This paper addresses the gap that existing methods rely on holistic EEG embeddings, the authors propose modeling three complementary views (temporal, spectral, and spatial) separately and then fusing them, which is a well-motivated and clearly reasoned way. The authors use design choices specifically tailored to the characteristics of EEG signals: the use of learnable wavelet decomposition in place of fixed frequency bands for spectral modeling, and of an attention-modulated dynamic graph for spatial modeling.
- Solid empirical validation: the method outperforms existing approaches across all three settings (within-subject, cross-subject, and cross-session), and is supported by complete ablations of both the modules and the regularizers.
Weaknesses:
- Looking at Table 2 subject by subject, the method actually trails the baselines on several subjects (e.g., sub3 is below UMind and ATM-S, sub4 is below UMind), and the 15.3% average lead is largely driven by a subset of subjects. However, the paper emphasizes that the method has a higher median, lower variance, and greater stability, which doesn't align with the per-subject data very well. The claimed cross-subject SOTA holds mainly in an average sense rather than as a consistent lead.
- From my perspective, it seems that all experiments come from a single fixed random seed (from Section 4.3 and Appendix C). The results has no variance or confidence intervals reported across multiple runs. This design setting may need discussion given that EEG decoding is inherently high-variance, and that the paper positions lower variance and stronger robustness as one of its core selling points.
- The cross-session evaluation is compared against only a single baseline (UBP). Since this is a newly defined protocol introduced by the authors, several baselines should be compared under it.
- The module ablation (in Table 4) is conducted on only a single subject (sub10), which may be too sample to support the general conclusion that the temporal, spectral, and spatial modules are each indispensable. A better way is to average across multiple subjects.
Questions
The paper's core claim is that the combination of temporal/spectral/spatial outperforms holistic EEG embeddings. The current ablation only shows that removing a view drops performance, which demonstrates each view contributes but not that the multi-view decomposition itself yields gains beyond a single sufficiently strong backbone. So, could you add a control comparing your three-view framework against a parameter-matched single-branch encoder (e.g., directly encoding raw multi-channel EEG with S3M/Transformer alone) under the same alignment objective and regularizers? If the two perform comparably, the gains stem mainly from encoding capacity rather than the multi-view structure. If the three-view design is clearly better, it would directly support the paper's core claim.
Limitations
Yes
Final justification
I raised my rating from 3 to 4. The rebuttal is detial on the experimental side: a parameter-matched single-branch control, an all-subject ablation, five-seed runs, significance tests against all baselines, and in the final round two extra cross-session baselines adapted to the held-out-session protocol.
That said, my rating reflects the rebuttal more than the original framing. The claims have shrunk quite a lot along the way: SOTA is now scoped to peer-reviewed methods available at submission; the cross-subject claim went from higher median and lower variance to highest average, with the margin over ATM-S and UMind not significant; "first systematic" now carries three qualifiers; "non-redundant, complementary" became "less-aligned learned subspaces"; and complementarity is now only the claim that the full model is best on average, with the authors agreeing that not every two-view combination helps. Each revision is fair on its own, but three of the four contributions have been weakened, and what is left is a solid three-branch EEG encoder with good within-subject numbers and a useful but still thinly compared cross-session protocol. Also, one number worth flagging: under cross-session, the Top-1 margin over UBP is 1.12 points and not significant (p=0.1250). The two new baselines are much weaker and do not change that, though the Top-5 gain is large and significant.
I think accept now outweighs reject, but I would not object if the AC weighs the contribution level differently from the technical soundness.
Formatting concerns
N/A
9 comments
Rebuttal Reply Part 1
We thank Reviewer FNeP for the careful evaluation and constructive feedback. We appreciate the insightful comments and have addressed each point below through additional analyses, experiments, and clarifications to better support our claims.
Weaknesses
Reply W1: We thank the reviewer for this careful observation. We agree that our method does not outperform every baseline on every individual subject, and we did not intend to imply consistent superiority across all subjects in the cross-subject setting. Our claim of improved performance refers to the overall average performance across all subjects, which is the standard evaluation protocol used in prior THINGS-EEG-related studies. To avoid overstatement, we will revise the manuscript to clarify that the proposed method achieves the highest average cross-subject performance among the compared methods, while acknowledging that performance varies across individual subjects due to substantial inter-subject variability inherent to EEG decoding. For part of your concern please refer to our response W4, Table 2 under Reviewer Jsns.
Reply W2: We thank the reviewer for this valuable suggestion. To assess sensitivity to random initialization, we repeated the within-subject experiments using five independent random seeds. Table 1 reports the mean ± standard deviation across the five runs for each subject. The five-seed results remain highly consistent with the originally reported single-seed performance: the average Top-1 accuracy remains 54.8 ± 7.84, while Top-5 changes only from 85.6 ± 6.35 to 85.8 ± 5.34. The relatively small per-subject standard deviations across the five runs further indicate that performance is stable across different random initializations. We also observe reduced across-subject variability when results are averaged over five seeds. The across-subject standard deviation decreases from 8.52 to 7.84 for Top-1 and from 6.35 to 5.34 for Top-5. Thus, averaging across independent runs not only preserves the overall performance but also yields a more stable estimate across subjects. These additional experiments provide stronger evidence that the reported results are reproducible and are not dependent on a particular random initialization. We will include these results in the revised version.
Table 1. Performance over five random seeds (mean ± standard deviation) for the within-subject setting.
| Metric | S01 | S02 | S03 | S04 | S05 | S06 | S07 | S08 | S09 | S10 | Avg. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Top-1 | 53.20 ± 2.39 | 51.30 ± 2.51 | 57.10 ± 1.75 | 54.10 ± 2.43 | 38.60 ± 2.58 | 52.50 ± 3.48 | 52.60 ± 1.78 | 65.70 ± 1.89 | 56.00 ± 2.89 | 66.60 ± 2.30 | 54.8 ± 7.84 |
| Top-5 | 85.30 ± 1.35 | 83.40 ± 2.33 | 88.40 ± 2.75 | 86.20 ± 1.30 | 73.60 ± 3.60 | 87.20 ± 2.59 | 83.40 ± 2.88 | 91.40 ± 1.56 | 85.90 ± 1.29 | 93.30 ± 1.96 | 85.8 ± 5.34 |
Reply W3: We agree that additional cross-session baselines would further strengthen the evaluation. However, existing EEG–visual decoding methods do not report results under our held-out-session protocol. We selected UBP because it was the strongest state-of-the-art baseline in our study, making it the most informative method for evaluating the proposed cross-session setting. Extending additional baselines to this protocol would require modifying their original training and evaluation pipelines. We therefore use UBP as the primary cross-session comparison and explicitly acknowledge the limited number of baselines. We hope the proposed protocol will facilitate broader cross-session comparisons in future work.
Rebuttal Reply Part 2
Reply W4: We agree that reporting ablation results averaged across all subjects provides stronger evidence for the contribution of each proposed component. In response to the reviewer's comment, we have added a table for within-subject ablation results averaged over all subjects, replacing the previous single-subject analysis. The updated results consistently show that each proposed module (temporal/spectral/spatial multiview fusion strategy) contributes positively to overall performance, demonstrating that the effectiveness of the proposed architecture is consistent across subjects rather than dependent on a representative individual. Moreover, the expanded ablation across all ten subjects confirms the importance of each branch. The temporal branch contributes most strongly: removing it reduces average Top-1/Top-5 accuracy from 54.8%/85.6% to 33.1%/64.7%, and Temporal Only is the strongest single-branch model. However, temporal modeling alone remains 10.1% below the full model in Top-1 and 6.9% below in Top-5. Removing the spatial or spectral branch also reduces Top-1 accuracy by 10.1% and 8.8%, respectively. These results show that temporal information provides the main foundation, while spatial and spectral information add complementary gains required for the best average performance across subjects. We will include these results in the revised version.
Table 2. Subject-wise ablation study across all ten subjects (Top-1% / Top-5%).
| Configuration | S01 | S02 | S03 | S04 | S05 | S06 | S07 | S08 | S09 | S10 | Avg. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Full Model | 53.0 / 84.5 | 51.0 / 84.0 | 58.0 / 88.0 | 55.0 / 88.0 | 38.0 / 69.5 | 54.5 / 87.0 | 51.0 / 84.5 | 67.5 / 89.0 | 52.5 / 87.5 | 67.5 / 94.0 | 54.8 / 85.6 |
| w/o Temporal | 36.5 / 71.0 | 10.5 / 30.5 | 43.5 / 84.0 | 27.0 / 52.0 | 17.5 / 42.5 | 15.5 / 43.5 | 33.0 / 67.0 | 47.0 / 87.5 | 36.5 / 77.0 | 63.5 / 92.0 | 33.1 / 64.7 |
| w/o Spatial | 37.0 / 70.0 | 46.5 / 81.5 | 44.5 / 78.5 | 47.5 / 82.0 | 31.0 / 74.0 | 50.5 / 83.5 | 37.5 / 74.5 | 51.0 / 84.5 | 41.5 / 79.0 | 60.0 / 90.0 | 44.7 / 79.8 |
| w/o Spectral | 36.5 / 73.0 | 47.5 / 76.0 | 47.0 / 85.0 | 44.5 / 79.0 | 35.5 / 69.0 | 52.5 / 82.5 | 38.5 / 78.5 | 52.5 / 84.5 | 46.5 / 80.0 | 59.0 / 92.0 | 46.0 / 80.0 |
| Temporal Only | 37.0 / 71.5 | 45.5 / 76.0 | 47.0 / 85.5 | 42.0 / 79.5 | 38.0 / 69.5 | 46.0 / 79.0 | 40.0 / 77.0 | 52.0 / 84.5 | 41.5 / 78.0 | 57.5 / 86.0 | 44.7 / 78.7 |
| Spatial Only | 37.5 / 72.5 | 19.5 / 45.0 | 42.5 / 77.0 | 20.0 / 46.5 | 16.0 / 43.0 | 34.5 / 68.5 | 31.5 / 69.0 | 49.0 / 83.0 | 36.5 / 74.0 | 49.5 / 83.0 | 33.7 / 66.2 |
| Spectral Only | 34.5 / 74.0 | 32.0 / 64.5 | 37.5 / 75.5 | 26.0 / 60.5 | 33.5 / 68.0 | 20.0 / 48.0 | 40.0 / 76.0 | 55.5 / 88.5 | 41.5 / 74.0 | 54.0 / 89.0 | 37.5 / 71.8 |
Rebuttal Reply Part 3
Reply Q1: We thank the reviewer for this insightful suggestion. In response to the reviewer's suggestion, we have added a table that includes a parameter-matched single-branch encoder trained with the same alignment objective and EEG-specific regularizers as our proposed framework. The comparison shows that the proposed multi-view architecture consistently outperforms the single-branch counterpart despite having comparable model capacity. These results indicate that the observed improvements arise from the explicit temporal–spectral–spatial decomposition rather than simply from increased model capacity, thereby providing stronger support for our central claim. We will include these results in the revised version.
Table 3: Parameter-matched single-view comparison across all subjects.
| Configuration | Params | S01 | S02 | S03 | S04 | S05 | S06 | S07 | S08 | S09 | S10 | Avg. |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Single-View S³M | 8.07M | 29.0 / 63.0 | 41.5 / 71.0 | 39.5 / 73.5 | 39.5 / 70.5 | 31.5 / 68.0 | 41.0 / 74.5 | 36.5 / 66.0 | 48.0 / 78.0 | 32.0 / 67.5 | 46.0 / 81.5 | 38.5 / 71.4 |
| Single-View Transformer | 8.69M | 45.0 / 72.5 | 45.0 / 76.0 | 47.0 / 82.0 | 50.5 / 84.0 | 41.0 / 75.5 | 52.0 / 82.0 | 46.5 / 79.5 | 56.0 / 84.5 | 45.5 / 77.0 | 60.0 / 87.5 | 48.9 / 80.1 |
The parameter-matched experiments further support the contribution of the multiview design. The Single-View Transformer has a slightly larger parameter count than our model (8.69M vs. 8.59M), yet achieves only 48.9% Top-1 and 80.1% Top-5 accuracy, compared with 54.8% and 85.6% for our multiview model. This corresponds to improvements of 5.9% in Top-1 and 5.5% in Top-5, despite using slightly fewer parameters. Our model also outperforms the Single-View S3M by 16.3% Top-1 and 14.2% Top-5. These results indicate that the performance gain cannot be explained simply by increased parameter capacity and provide direct evidence that combining temporal, spectral, and spatial representations contributes to the improvement.
We thank the reviewer for acknowledging the limitations discussed in the paper. The specific concerns regarding cross-subject variability, cross-session comparison, random-seed stability, and ablation coverage are addressed in detail in our responses above, including additional experiments and analyses.
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This manuscript proposes a multiview EEG–Image decoding framework that learns EEG representations within the CLIP embedding space for zero-shot visual decoding. Keeping a frozen CLIP as a fixed semantic target, it trains an EEG encoder that jointly models three complementary views—temporal dynamics via a selective state-space model (S³M), adaptive frequency structure via a learnable wavelet decomposition (ALWD), and spatial electrode interactions via a dynamic graph convolutional network (GCN). The fused EEG embedding is aligned with the visual representations through contrastive learning plus two EEG-specific regularization terms. The method is evaluated on THINGS-EEG for 200-way zero-shot classification under within-subject (54.8% Top-1 and 85.6% Top-5 accuracy), cross-subject (15.3% Top-1 and 45.4% Top-5 accuracy), and cross-session (40.8% Top-1 and 78.0% Top-5 accuracy) settings. The authors present their model with a high level of detail with some ablation studies.
Strengths and weaknesses
Strengths
- The EEG encoder is the main contribution and is both novel and effective; Decomposing EEG signal into temporal, spectral, and spatial components is an effective method, and this leads a competitive performance in within-subject performance, especially competitive Top-5 accuracy.
- The authors clearly illustrate the model structure from temporal, spatial and spectral perspective.
- The within-subject case gains strong outcomes, which is outstanding the most models. Meanwhile, the other evaluations including cross-subject and cross-session are included for comprehensive protocols.
- The authors conduct the interpretability analysis with spatial patterns in visual cortex.
- The authors select strong baseline models and THINGS-EEG dataset for clear comparisons.
Weaknesses
- Cross-subject performance is relative low (Top-1 only 15.3%) as comparing with the with-in subject outcomes. This may bring some limitation in model generalization and further real-world usage.
- Evaluation is not independent of training: the encoder is trained to align with CLIP prototypes and evaluated by nearest-prototype classification in the same space. It seems the semantic decoding generalisation is not clear.
- Ablation study has been conducted on Subject 10 and within-subject situation. However, it would bring benefits and clarify of model structure as including more factors in ablation study.
- The error bar has been used in the overall performance. It would be great to have some statistical tests which can bring meaningful difference in some comparisons, like the comparisons across models.
Questions
- Could the authors provide ablation results averaged over all subjects?
- From within-subject to cross-subject results, the model generalization would be one issue. It would be tricky to address and discuss the issues.
- Fixed random seed(s) has been used in the method. I am wondering to see more performance/outcomes under multiple random seeds.
Limitations
The cross-subject EEG analysis and its classificaiton/prediciton are still there. But the authors have discussed this issue in the rebuttal stage.
Final justification
The rebuttal and newly added experiments well addressed the issues in my review. The most concern in my review is the ablation study to Subject 10 only. In the rebuttal, the authors had new experiment results to showcase all findings across all 10 subjects. The statistic tests have been included for proper numerical comparisons across the performance. The experiment about the fix seed and random seed has been conducted as well. I will have my rate as accept for camera-ready version. However, I will follow AC and other reviewers' decisions.
Formatting concerns
N/A
7 comments
Rebuttal Reply Part 1
We sincerely thank Reviewer Jsns for the careful reading of our manuscript and for the constructive and insightful comments. We appreciate the reviewer's valuable feedback and address each concern below with additional analyses, experiments, and clarifications.
Weaknesses
Reply W1: We thank the reviewer for this important observation. This limitation is already acknowledged in Appendix E, where we state that fully subject-invariant EEG decoding remains an open challenge and that generalization to real-world settings is still uncertain. Cross-subject decoding is inherently more difficult than within-subject decoding because the model must generalize to an entirely held-out subject, despite substantial inter-subject differences in EEG characteristics and neural responses. This performance gap is also observed across existing THINGS-EEG methods and is not specific to our approach.
Although the absolute Top-1 accuracy is 15.3%, it is substantially above the 0.5% chance level of the 200-way task and remains competitive with existing methods. Our framework primarily focuses on learning effective temporal, spectral, and spatial EEG representations rather than explicitly addressing cross-subject domain adaptation. Nevertheless, it achieves competitive cross-subject performance while maintaining strong within-subject and cross-session results. We will make this limitation more explicit in the main discussion and highlight subject-invariant representation learning and domain adaptation as important future directions.
Reply W2: We appreciate this insightful comment. We clarify that training and evaluation use the same frozen CLIP semantic space, but they are independent at the sample and category levels. During training, the EEG encoder is optimized using only EEG–image pairs from the training categories. The EEG trials, images, and semantic categories used for testing are completely held out and do not contribute to model optimization.
At inference, the trained EEG encoder is applied to EEG signals from previously unseen categories. Their CLIP prototypes are introduced only during evaluation, and classification is performed by identifying the nearest prototype. Therefore, the model cannot simply memorize the training prototypes; it must transfer the learned EEG-to-semantic mapping to new visual categories.
Using the same frozen semantic space for training and inference is the mechanism that enables zero-shot decoding, rather than a form of training–test leakage. The reported results, therefore, measure generalization to unseen EEG samples, images, and semantic categories within the shared CLIP space. We will clarify this protocol more explicitly in the manuscript. Accordingly, our claim is generalization to unseen EEG samples, images, and semantic categories within the fixed CLIP semantic space, rather than generalization to an entirely different semantic representation space.
Rebuttal Reply Part 2
Reply W3: We thank the reviewer for this valuable suggestion. We agree that reporting ablation results averaged across all subjects provides stronger evidence for the contribution of each proposed component. Accordingly, we will revise the manuscript by replacing the single-subject ablation with a comprehensive within-subject ablation, averaged across all subjects (see the revised Table 1 given below). The updated results consistently show that each proposed module (temporal/spectral/spatial multiview fusion strategy) contributes to the final performance, demonstrating that the contributions of the proposed components are preserved when evaluated across the entire subject cohort rather than a single subject.
Moreover, the expanded ablation across all ten subjects confirms the importance of each branch. The temporal branch contributes most strongly: removing it reduces average Top-1/Top-5 accuracy from 54.8/85.6 to 33.1/64.7, and Temporal Only is the strongest single-branch model. However, temporal modeling alone remains 10.1% below the full model in Top-1 and 6.9% below in Top-5. Removing the spatial or spectral branch also reduces Top-1 accuracy by 10.1% and 8.8%, respectively. These results show that temporal information provides the main foundation, while spatial and spectral information add complementary gains required for the best average performance across subjects. We will include this discussion in the revised version.
Table 1: Ablation results across all subjects.
| Configuration | S01 | S02 | S03 | S04 | S05 | S06 | S07 | S08 | S09 | S10 | Avg. |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Full Model | 53.0 / 84.5 | 51.0 / 84.0 | 58.0 / 88.0 | 55.0 / 88.0 | 38.0 / 69.5 | 54.5 / 87.0 | 51.0 / 84.5 | 67.5 / 89.0 | 52.5 / 87.5 | 67.5 / 94.0 | 54.8 / 85.6 |
| w/o Temporal | 36.5 / 71.0 | 10.5 / 30.5 | 43.5 / 84.0 | 27.0 / 52.0 | 17.5 / 42.5 | 15.5 / 43.5 | 33.0 / 67.0 | 47.0 / 87.5 | 36.5 / 77.0 | 63.5 / 92.0 | 33.1 / 64.7 |
| w/o Spatial | 37.0 / 70.0 | 46.5 / 81.5 | 44.5 / 78.5 | 47.5 / 82.0 | 31.0 / 74.0 | 50.5 / 83.5 | 37.5 / 74.5 | 51.0 / 84.5 | 41.5 / 79.0 | 60.0 / 90.0 | 44.7 / 79.8 |
| w/o Spectral | 36.5 / 73.0 | 47.5 / 76.0 | 47.0 / 85.0 | 44.5 / 79.0 | 35.5 / 69.0 | 52.5 / 82.5 | 38.5 / 78.5 | 52.5 / 84.5 | 46.5 / 80.0 | 59.0 / 92.0 | 46.0 / 80.0 |
| Temporal Only | 37.0 / 71.5 | 45.5 / 76.0 | 47.0 / 85.5 | 42.0 / 79.5 | 38.0 / 69.5 | 46.0 / 79.0 | 40.0 / 77.0 | 52.0 / 84.5 | 41.5 / 78.0 | 57.5 / 86.0 | 44.7 / 78.7 |
| Spatial Only | 37.5 / 72.5 | 19.5 / 45.0 | 42.5 / 77.0 | 20.0 / 46.5 | 16.0 / 43.0 | 34.5 / 68.5 | 31.5 / 69.0 | 49.0 / 83.0 | 36.5 / 74.0 | 49.5 / 83.0 | 33.7 / 66.2 |
| Spectral Only | 34.5 / 74.0 | 32.0 / 64.5 | 37.5 / 75.5 | 26.0 / 60.5 | 33.5 / 68.0 | 20.0 / 48.0 | 40.0 / 76.0 | 55.5 / 88.5 | 41.5 / 74.0 | 54.0 / 89.0 | 37.5 / 71.8 |
Rebuttal Reply Part 3
Reply W4: We thank the reviewer for this valuable suggestion. To assess whether the observed performance differences are statistically meaningful, we performed paired two-sided t-tests on subject-level accuracies between our method and each baseline, using p < 0.05 as the significance threshold.
Within-subject: Our improvements are statistically significant over all compared baselines for both Top-1 and Top-5 accuracy.
Cross-subject: For Top-1 accuracy, the proposed method achieves statistically significant improvements over BraVL, NICE, NICE-SA, NICE-GA, and UBP. The comparisons with ATM-S (p=0.0802) and UMind (p=0.0931) do not reach statistical significance, indicating that although our method achieves higher average Top-1 accuracy, the margin is not sufficiently large relative to the inter-subject variability to establish significance at the 0.05 level. For Top-5 accuracy, the improvements are statistically significant over all compared baselines.
Cross-session: The proposed method achieves higher average Top-1 accuracy than UBP; however, this difference is not statistically significant (p=0.1250). We attribute this to the limited statistical power of the evaluation (ten subjects) together with the relatively small Top-1 performance gap under the more challenging cross-session setting. In contrast, the Top-5 improvement is substantial and statistically significant (p=1.92 × 10⁻⁵), indicating a consistent advantage in retrieval performance.
Table 2: Statistical significance of our method against the compared methods.
1. Within-subject
| Metric | BraVL | NICE | NICE-SA | NICE-GA | ATM-S | UMind | UBP |
|---|---|---|---|---|---|---|---|
| Top-1 p-value | 3.16 × 10⁻⁸ | 2.10 × 10⁻⁷ | 4.37 × 10⁻⁷ | 5.33 × 10⁻⁷ | 1.83 × 10⁻⁷ | 4.11 × 10⁻⁸ | 0.0410 |
| Top-5 p-value | 3.32 × 10⁻¹⁰ | 7.55 × 10⁻⁸ | 3.15 × 10⁻⁶ | 3.65 × 10⁻⁶ | 1.12 × 10⁻⁷ | 1.62 × 10⁻⁶ | 0.00479 |
2. Cross-subject
| Metric | BraVL | NICE | NICE-SA | NICE-GA | ATM-S | UMind | UBP |
|---|---|---|---|---|---|---|---|
| Top-1 p-value | 8.98 × 10⁻⁸ | 1.76 × 10⁻⁶ | 3.79 × 10⁻⁶ | 3.11 × 10⁻⁶ | 0.0802 | 0.0931 | 0.00734 |
| Top-5 p-value | 9.37 × 10⁻⁹ | 5.39 × 10⁻⁷ | 9.35 × 10⁻⁷ | 4.98 × 10⁻⁷ | 0.00454 | 0.00344 | 3.85 × 10⁻⁴ |
3. Cross-session
| Baseline | Top-1 p-value | Top-5 p-value |
|---|---|---|
| UBP | 0.1250 | 1.92 × 10⁻⁵ |
In addition, we repeated our experiments over five independent random seeds and will report the corresponding mean ± standard deviation, providing further evidence of stability across random initializations (See Reviewer FNeP, Reply W2, Table1). We will include these results in the revised manuscript.
Questions:
Reply Q1: We thank the reviewer for this suggestion. Yes. We have expanded the ablation analysis from Subject 10 to all ten subjects; the complete results are provided in Table 1 of Reply W3. The full model achieves the highest average performance, while removing any of the temporal, spectral, or spatial branches reduces performance. The revised manuscript will replace the original single-subject ablation with this all-subject analysis.
Reply Q2: We agree with the reviewer that cross-subject EEG decoding remains one of the most challenging problems in the field. The substantial performance drop mainly arises from large inter-subject differences in cortical responses, signal characteristics, and recording variability, which significantly reduce feature alignment across individuals. Our proposed multiview representation improves robustness by jointly modeling temporal, spectral, and spatial information, but it is not specifically designed as a domain adaptation or subject-invariant learning framework. This limitation is already acknowledged in Appendix E, where we explicitly state that “fully subject-invariant EEG decoding remains an open challenge”. We will therefore make this limitation more explicit in the main discussion and identify subject-invariant representation learning and domain adaptation as important directions for future work.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 2/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This work addresses the challenge of zero-shot visual decoding from electroencephalography (EEG) signals, mapping the electrophysiological dynamics to semantic visual spaces. The contributions of the paper are centered on a parallel, three-branch EEG encoder designed to factorize the neural activity into three complementary views: Temporal dynamics (modeled using a Selective State-Space Model, ), Spectral dynamics (modeled using a learnable wavelet decomposition, ALWD), and Spatial dynamics (modeled using a Graph Convolutional Network, GCN). To stabilize alignment with a frozen CLIP visual backbone, the authors introduce two task-specific losses: Repetition Consistency Regularization () and Prototype-Level Contrastive Regularization (). The framework is evaluated on the THINGS-EEG benchmark, reporting a within-subject Top-1 retrieval accuracy of 54.8%, a cross-subject Top-1 accuracy of 15.3%, and a cross-session Top-1 accuracy of 40.8%
Strengths and weaknesses
- Strengths
-
The combination of state-space models for temporal dynamics and learnable wavelets for spectral decomposition represents a motivated step forward, moving beyond rigid, task-agnostic frequency bands typical in classical BCI pipelines
-
Unlike most studies that restrict evaluation to simple within-subject decoding, this manuscript evaluates its encoder on more challenging cross-subject and cross-session paradigms to systematically analyze model robustness against non-stationarity.
3.The reported results demonstrate meaningful improvements over traditional, flat representation baselines like NICE-EEG.
- Weaknesses
-
The authors assert that they present the "first systematic cross-session EEG-image decoding evaluation". This claim overstates their novelty. Session-to-session variability and cross-session evaluation have long been standard in electrophysiological decoding and BCI research. For the specific task of visual semantic decoding, contemporary benchmarks like CrossPT-EEG (Zhu et al., 2025) and other cross-session visual paradigms have already formalized these temporal splits. To position this work accurately, the authors must qualify this claim, specifying that they present the first systematic evaluation of zero-shot, cross-session visual semantic retrieval without post-hoc target labels.
-
The paper argues that existing methods rely on "holistic EEG embeddings" which obscure spatiotemporal structure. Howver the paper misses critical recent work that addresses EEG-visual alignment and foundation modeling, which are essential for situating its novelty. Models like S-JEPA (Guetschel et al., 2024) employ spatial block masking to force the model to capture structured spatial dependencies and dynamic channel attention. Brain-JEPA (Dong et al., 2024) utilizes functional gradient-based positional encodings and spatiotemporal masking to model brain dynamics. EEGPT (Wang et al., 2024) deconstructs the signals via an electrode-wise modeling strategy to learn the temporal and spatial dependencies. EEG-DINO (Wang et al., 2025) utilizes hierarchical self-distillation over multi-view channel- and time-augmented views. Referring to previous literature as purely "holistic" and "flat", the manuscript fails to acknowledge that high-capacity foundation architectures explicitly or implicitly learn these structured spatial-temporal relationships at scale. Further, the absence of these baselines makes the unified-framework framing harder to assess
-
The authors claim to achieve state-of-the-art results on the THINGS-EEG benchmark. However, this is directly contradicted by contemporary visual decoding literature. SAMGA (Jiang et al., 2026) explicitly addresses the subject-dependent visual granularity mismatches by routing intermediate visual representations to form subject-aware visual targets. Under identical zero-shot protocols on the THINGS-EEG benchmark, SAMGA achieves 91.3% within-subject Top-1 and 34.4% cross-subject Top-1 outperforming the submitted method by a 36.5% and 19.1% in Top-1 accuracy, respectively.
-
The authors perform cosine similarity and Centered Kernel Alignment (CKA) analyses, reporting low off-diagonal similarities () to prove that the Temporal, Spectral, and Spatial branches extract non-redundant, complementary information. This contains a logical and geometric flaw. The Spectral branch is derived directly from the Temporal signal via ALWD filters. They are inherently coupled. From a geometric perspective, the near-orthogonal representations are largely an artifact of centering and batch normalization operations within deep architectures. The low CKA/cosine similarity scores simply indicate that the projection head () has orthogonalized the output vectors prior to computing contrastive loss, rather than proving that the encoder backbone is extracting fundamentally disjoint physical information.
-
A major theoretical limitation of this work is its exclusive reliance on aligning EEG representations to the final layer of a frozen CLIP vision backbone. Pretrained contrastive models like CLIP are trained to align highly semantic text and image modalities, forcing their final-layer embeddings to undergo extreme representation collapse. This collapse discards low-level and mid-level visual structures in favor of abstract concepts. Now here arises a puzzling conceptual question specially related to the ambitious title of the paper, What Does the Brain See? If one adopts the "classical" view, namely that the biology of the human visual system, processes visual stimuli progressively across a hierarchical cascade- from low-level edges in early visual cortex to high-level semantics in downstream temporal regions, what the authosr embrace contradicts this view. On the other hand, if one claims for the opposite view, the predictive/Bayesian brain, I honestly hardly see any relations to the algorithmic/implementation model (in the Marr's sense) designed by the authors.
-
State-of-the-art architectures, such as SUPA-EEG (Beckmann et al., 2025) and SAMGA (Jiang et al., 2026), address this by aligning EEG features with intermediate representations of a vision backbone (like InternViT or I-JEPA). This was shown to preserve the multi-scale visual details that are actually encoded in early sensory-evoked EEG potentials. Since the authors do not provide an ablation or comparison with alternative visual targets (e.g., intermediate layers, or non-contrastive self-supervised models like I-JEPA/DINOv2), it is highly probable that their multiview EEG encoder is simply overfitting to the specific text-biased geometric anomalies of the frozen CLIP ViT-H-14 final layer.
-
The proposed repetition-consistency regulariser
objective penalizes the Euclidean distance between single-trial EEG embeddings and the repetition-averaged reference embedding computed across multiple presentations of the same stimulus. This formulation directly contradicts the established neuroscience of repetition suppression (sensory adaptation). Repeated presentations of a visual stimulus do not yield identical, noisy neural patterns but rather they trigger structured and biophysically meaningful changes in the cortical representation (Engell et al., 2014, Hsu et al., 2023). By forcing single-trial representations of early (novel) and late (adapted) presentations to match a rigid, static average reference, $\mathcal{L}_{\mathrm{RCR}} suppresses teh true cognitive dynamics. In simple terms: repetition suppression is a robust effect; treating these adaptations as noise is in contrast with the paper's claim to model "true cognitive dynamics." The similarity-conditioned weighting modulates strength but not direction
- The Prototype-Level Contrastive Regularization () anchors the EEG representations to class prototypes. It is unclear if the compared baselines (e.g., NICE-EEG, ATM-S) were evaluated with this class-aware prototype loss. If the baselines were trained solely on instance-level contrastive objectives, the reported performance gains may stem from the semantic structure of the loss function itself rather than the "Multiview" architectural design.
Overall, I find this submission presents an interesting synthesis of temporal, spectral, and spatial architectural blocks, achieving strong performance relative to historical baselines like NICE-EEG and ATM-S. However, the paper suffers from substantial limitations regarding overstated novelty, major omissions of the contemporary state-of-the-art literature and neurobiological contradictions in its training objectives. In a crude synthesis: the within-panel work is ok and the cross-session protocol is useful, but the main claims (SOTA, branch-disentanglement, multi-view as the source of the gain) are not, on the reported evidence, defensible
Questions
-
Applying the and losses to a standard transformer baseline (like NICE-EEG), does the performance gap close? This is critical to isolate the contribution of your multiview architecture from the loss formulation.
-
Why choose concatenation as the primary fusion mechanism? Did you explore more sophisticated integration (e.g., cross-view attention) to model dependencies between temporal dynamics and spatial patterns?
-
Since repetition suppression systematically alters ERP components and spectral bands, does the penalty disproportionately degrade decoding performance on the final repetitions of a stimulus? An analysis of decoding accuracy stratified by trial repetition number () would better clarify this point.
-
In your cross-session and cross-subject splits, are the test segments temporally disjoint from the training segments to prevent leakage via temporal autocorrelation?
-
Please clarify how you defined "recording noise" and "electrode contact" shifts in your cross-session protocol. Are these physical measurements or assumed distribution shifts?
-
In light of recent unified architectures like ENIGMA (Kneeland et al., 2025), which achieve robust multi-subject visual decoding with a simple spatio-temporal backbone and ~120x fewer parameters, how do you justify the massive parameter footprint and high computational complexity of your parallel three-branch (SSM, Wavelet, GCN) design?
-
To prove your multiview EEG encoder is capturing real, multi-scale visual dynamics rather than overfitting to the text-biased final layer of CLIP. Can you provide an ablation study mapping your EEG representations to intermediate layers of your vision backbone (similar to SAMGA or SUPA-EEG)? Can you evaluate alignment performance when using a purely visual self-supervised target (like I-JEPA or DINOv2) which explicitly preserves local spatial structures, compared to the text-aligned CLIP space?
Limitations
Appendix E acknowledges single-dataset evaluation, residual cross-subject variability, and reliance on frozen CLIP, and flags privacy/ethical concerns appropriate for EEG-as-neural-data. The discussion does \emph{not} engage with: the contemporary SOTA claims that potentially supersede those reported in this paper; the absence of foundation-model baselines; the theoretical mismatch between CLIP-final alignment and the neurobiology of early visual processing; the RCR/repetition-suppression conflict. These should be addressed in the rebuttal.
Final justification
After having considered the whole rebuttal cycle with respect to my objections/authors responses and those raised by other reviewers, and in consideration of the remarkabkle effort put by the authors along the rebiuttal phase, I shall change my rating from the initial reject to borderline accept. I substantially agree with reviewer FNeP final justification and my decision is driven mostly by some overall new evidence rather than by a change of view on the paper as originally written.
My central methodological objection was that the reported gain could not be attributed to the multiview decomposition, because architecture, capacity and the two new regularisers were confounded. The authors ran the control I asked for (ATM-DWT , etc), and this was a clean test and coming out in the authors' favour. On the technical-soundness axis the paper is now in acceptable shape, and I credit the authors for doing this hard work inside a short window.
My other objections were answered by narrowing the claims rather than by evidence, so that the cumulative effect of those narrowings is what keeps me at the bottom of the accept range rather than above it. The SOTA claim is now conditional on "peer-reviewed methods available at submission"; I accept the March 2026 contemporaneity rule, but the accepted-as-fair scoping does not alter the substantial fact that the paper's numbers are unlikely to read as state of the art by publication time. The cross-subject claim has retreated from "higher median, lower variance" to "highest average", with the margins over ATM-S and UMind not significant. "Non-redundant, complementary" has become "less-aligned learned subspaces", which I agree is the fair reading but is also close to saying nothing: the spectral branch is a deterministic transform of the temporal signal, and the authors declined the fixed-wavelet control that would have separated learned decorrelation from architectural artefact. Complementarity now amounts to the observation that the full model is best on average, the authors having conceded that not every two-view combination helps. Overall I must say that "first systematic" claim survives only with three qualifiers attached.
Also, I asked whether the title and narrative commit the paper to a position on visual processing. The authors' answer was that "What Does the Brain See?" refers to what can be decoded, not to how the brain computes, and that final-layer CLIP is a fixed target of convenience with no claimed correspondence to cortical stages. I certainly accept this as a statement of scope, and the promised addition to the Limitations section is the right remedy. Nevertheless I have this uncomfortable perception that a title asking what the brain sees, and a subtitle promising to demystify brain-visual alignment, set an high expectation that the delivered contribution (three-branch EEG encoder aligned to a frozen CLIP head) does not meet at all. Whether the final outcome would be an accept, though I do not know if it is formally possible according to NIPS rules, I would encourage the AC to ask at least for a title and abstract that match the retained claims. The current read as a residue of the overstatement that the discussion period removed everywhere else.
So, eventually, I would say that what remains is a competently engineered EEG encoder with strong within-subject retrieval on a dataset, a set of controls that now support the architectural attribution, and a cross-session protocol that is useful to the community. The remaining weaknesses are those of a currently narrow scope, not of soundness. Clearly, none of these is now a reason to reject. Yet, together they are a reason for me not too place the paper above the borderline.
I therefore settle at 4. But I would not resist a decision either way, and I would defer to the AC, and other colleqgues, whether the contribution level should be weighed more heavily than technical soundness. Basically, on the contribution side my own stance has not moved.
Formatting concerns
None in particular.
8 comments
Rebuttal Reply Part 1
We sincerely thank Reviewer Mrox for the careful evaluation of our work and for the constructive feedback and valuable suggestions. We appreciate the time and effort devoted to reviewing our manuscript. Below, we provide point-by-point responses to the comments and clarify the concerns raised. Where appropriate, we also include additional experiments to further support our claims.
General Comment: We rechecked the cited literature. While SAMGA is relevant concurrent work on THINGS-EEG, it was posted on arXiv on April 20, 2026, and currently remains a non-peer-reviewed preprint. Similarly, the public record indicates that SUPA-EEG is a THU 2026 Spring ANM course/project submission posted on April 28, 2026, rather than a 2025 peer-reviewed state-of-the-art publication. Accordingly, both works appeared after March 1, 2026, and therefore fall within the NeurIPS 2026 definition of contemporaneous work. The NeurIPS Main Track Handbook explicitly states that submissions should not be rejected on the basis of comparison with contemporaneous work (i.e., work appearing after March 1, 2026), while encouraging authors to cite and discuss such work to the extent feasible. We will, of course, cite and discuss these works in the revised version. We also note that S-JEPA, EEGPT, and EEG-DINO focus on broader EEG representation learning rather than directly comparable zero-shot THINGS-EEG retrieval, whereas Brain-JEPA is designed for fMRI. Nevertheless, we appreciate these relevant references and will discuss them appropriately in the revised manuscript.
Weaknesses Reply
Reply W1: We respectfully disagree that CrossPT-EEG [1] invalidates our novelty claim. CrossPT-EEG addresses a substantially different setting: it formulates cross-time decoding as supervised object classification, using category labels and cross-entropy loss with deep models such as MLP, EEGNet, and RGNN. Its “pre-training” setting also uses supervised pre-training and transfer, rather than contrastive or self-supervised EEG–visual alignment. In contrast, our protocol learns multimodal EEG–visual representations and evaluates zero-shot semantic retrieval on unseen visual categories. Therefore, CrossPT-EEG establishes cross-time supervised classification, but does not evaluate the zero-shot cross-session EEG–visual decoding protocol proposed in our work. We do not claim that cross-session EEG decoding itself is new. Our novelty claim is specifically the systematic evaluation of cross-session zero-shot EEG–image semantic decoding/retrieval under the proposed protocol. We will revise the wording to make this scope explicit.
Reply W2: We respectfully disagree with the treatment of these foundation models as missing EEG–visual decoding baselines. S-JEPA [2], EEGPT [3,4], and EEG-DINO [5] focus on general EEG representation learning and downstream EEG/BCI tasks rather than zero-shot EEG–image retrieval. Brain-JEPA [6] is an fMRI model, not an EEG baseline. The review also appears to conflate two EEGPT works: electrode-wise modeling is proposed by Yue et al. [4], whereas Wang et al. [3] use hierarchical spatial–temporal modelling. We do not claim that prior foundation models ignore temporal or spatial EEG structure. Our distinction is that they do not explicitly decompose temporal, spectral, and spatial representations into separate views for EEG–visual semantic alignment. We will cite these works as relevant representation-learning literature while maintaining that they are not directly comparable THINGS-EEG retrieval baselines. Our contribution is therefore not the general observation that EEG contains temporal or spatial structure, but the explicit modelling and fusion of temporal, spectral, and spatial EEG representations for EEG–visual semantic alignment.
Reply W3: SAMGA[7] reports the stated results, but important context is omitted. It was posted shortly before the NeurIPS deadline and remains a non-peer-reviewed preprint. Methodologically, SAMGA also addresses a different design dimension: it constructs subject-aware visual supervision by adaptively combining multiple intermediate visual representations, whereas our study keeps the visual target fixed and investigates the EEG representation architecture. Thus, although SAMGA is relevant, concurrent work on the same benchmark, its gains cannot be attributed to the same methodological setting as ours. We will cite this preprint while retaining our SOTA claim regarding peer-reviewed methods available at the time of submission. We also note that SAMGA does not evaluate cross-session generalization.
Rebuttal Reply Part 2
Reply W4: We respectfully disagree that the low similarities are merely artifacts of normalization or the final projection head. In our method, the temporal, spectral, and spatial branches independently process the EEG input, and cosine/CKA analysis is performed on the representations from each branch before final fusion/projection. Cosine similarity measures how similar the feature directions are, while CKA measures how similarly two representations organize the samples. Therefore, consistently low values across both measures indicate that the branches learn different, less redundant representations. We agree that this does not prove the existence of physically independent neural mechanisms.
Reply W5: We respectfully disagree that final-layer CLIP alignment constitutes a theoretical contradiction. Our objective is zero-shot semantic EEG–visual decoding, and does not claim a one-to-one correspondence between CLIP layers and stages of cortical visual processing. We use a frozen CLIP encoder as the semantic target to ensure a fair comparison with previous state-of-the-art methods and to isolate the contribution of our EEG encoder. We do not claim that the final-layer CLIP reproduces early-to-late cortical processing. Intermediate visual targets are a complementary research direction, not a prerequisite for validating the present EEG-encoder contribution.
Reply W6: We strongly disagree with the conclusion that CLIP-specific overfitting is “highly probable”. Our model generalizes to unseen categories, subjects, and sessions, while the visual encoder remains frozen. The CLIP ViT-H/14 visual encoder is used solely as a pretrained, frozen feature extractor, and its parameters are never updated during training. Therefore, we believe model can not overfit to the visual backbone itself. Furthermore, our evaluation follows a strict zero-shot EEG decoding protocol, where the test categories are completely unseen during training. The model is required to generalize to unseen image classes (and, depending on the evaluation setting, unseen subjects/sessions) rather than memorize training samples. Consequently, CLIP-specific overfitting is not possible.
Moreover, SUPA-EEG [8] is inaccurately characterized: the public OpenReview record is a THU Spring 2026 course/project submission dated 28 April 2026, not an established 2025 peer-reviewed SOTA publication, and it was posted shortly before the NeurIPS deadline. SAMGA [7] is likewise a recent non-peer-reviewed preprint. These works primarily modify the visual supervision target, whereas our contribution concerns the EEG representation architecture. The two directions are complementary. We will discuss alternative visual targets as future work, but their absence does not establish CLIP-specific overfitting.
Reply W7: We respectfully disagree that RCR “directly contradicts” repetition-suppression neuroscience. RCR acts only on the task-level semantic embedding; it neither forces raw EEG responses nor intermediate temporal/spectral activity to be identical across repetitions. Physiological adaptation and stimulus-invariant semantic decoding are therefore compatible. Moreover, the cited literature itself reports condition-dependent repetition suppression and enhancement, rather than a universally fixed repetition trajectory. Importantly, the phrase “true cognitive dynamics” cited in the review as attributed to our paper does not appear anywhere in the manuscript. Our claim is only that RCR reduces trial-level variability in the representation used for semantic decoding. We will clarify this distinction.
Reply W8: We agree that this control is necessary to separate the contributions of the loss formulation from those of the architecture. We therefore retrained ATM-DWT [9] using the identical CPCA and RCR objectives under the same training protocol as our method. As shown in Table 1 below, adding CPCA and RCR to ATM-DWT resulted in comparable performance to the original model (Top-1: 33.4% → 33.2%, Top-5: 61.8% → 62.3%), indicating that the semantic regularization alone does not account for the observed improvements. Under the same CPCA and RCR objectives, our proposed multiview encoder achieves 54.8% Top-1 and 85.6% Top-5, substantially outperforming ATM-DWT trained with the same objectives. Together with the single-branch control experiments (see Reviewer FNeP, Reply Q1, Table 3), these results demonstrate that the performance gains primarily arise from the proposed multiview architecture rather than from the addition of CPCA and RCR alone.
Table 1. Effect of adding CPCA and RCR losses to ATM-DWT.
| Model | Top-1 Avg. | Top-5 Avg. |
|---|---|---|
| ATM-DWT | 33.4 | 61.8 |
| ATM-DWT + CPCA + RCR | 33.2 | 62.3 |
| Ours | 54.8 | 85.6 |
Rebuttal Reply Part 3
Reply W-Summary: Thank you for the constructive summary. We respectfully disagree with this overall characterization. Several concerns arise from non-equivalent comparisons or factual mischaracterizations: the cited foundation models are not EEG–visual retrieval baselines; Brain-JEPA is an fMRI model; SUPA-EEG is a 2026 course/project submission rather than an established SOTA publication; and “true cognitive dynamics” is not a claim made in our paper. We nevertheless address the valid experimental concern regarding architecture/loss/capacity confounding through parameter-matched single-branch controls (S3M and Transformer-based) and ATM-DWT with identical regularization. The parameter-matched Single-View Transformer has slightly more parameters than our multiview model (8.69M vs. 8.59M), yet achieves 5.9%/5.5% lower Top-1/Top-5 performance. These additional controls directly test whether the multiview design itself provides the reported gain.
Questions Reply:
Reply Q1: We thank the reviewer for suggesting a useful control that strengthens our contribution. We evaluated ATM-DWT using the same CPCA and RCR objectives as our model. Compared with the originally reported ATM-DWT results, the added losses reduce the average Top-1 accuracy from 33.4% to 33.2% (-0.2 percent) and increase the Top-5 accuracy from 61.8% to 62.3% (+0.5 percent). In contrast, our full multiview model achieves 54.8% Top-1 and 85.6% Top-5 accuracy, retaining improvements of 21.6% and 23.3%, respectively, under the same objectives. Thus, the performance gap does not arise primarily from CPCA and RCR. Together with the parameter-matched single-branch experiments (see Reviewer FNeP, Reply Q1, Table 3), this separates the contributions of regularization, model capacity, and multiview decomposition.
Reply Q2: Concatenation was chosen deliberately as a simple, parameter-efficient fusion mechanism that preserves each view without introducing an additional learned interaction module. This allows the contribution of the temporal, spectral, and spatial encoders to be evaluated without confounding it with a sophisticated fusion architecture. Cross-view attention is a useful extension that we did not explore in the current study and will consider in future work.
Reply Q3: The premise that RCR necessarily suppresses repetition-related neural adaptation is not correct. RCR is applied to the final task-level semantic representation; it does not constrain the raw EEG, ERP components, spectral responses, or intermediate representations to remain identical across repetitions. Thus, physiologically meaningful adaptation can persist while the final representation retains the stimulus-consistent information required for decoding. We have not performed repetition-stratified decoding in the current study and therefore do not claim invariance of performance across repetition indices. We agree that such an analysis could provide additional insight into repetition-specific decoding behaviour, and we will identify it as a useful follow-up analysis. Importantly, the absence of this analysis does not establish that RCR suppresses adaptation.
Reply Q4: Yes. This separation is described in Sec. 4.2 (Task Definitions and Evaluation Protocols): for cross-subject evaluation, training uses multiple subjects, and testing uses an entirely held-out subject; for cross-session evaluation, training uses three complete recording sessions, and testing uses the held-out fourth session. Thus, training and test EEG signals are temporally disjoint, and temporally adjacent segments from the same recording are never shared across the splits. We will explicitly state this temporal disjointness in the revised Sec. 4.2 to avoid ambiguity.
Reply Q5: These factors were not independently measured or manipulated in our experiments. Rather, inter-session EEG variability and its potential sources, including time-varying subject state and recording/electrode variability, are well established in prior works [10-12]. Our cross-session protocol evaluates model generalization to a held-out recording session, without identifying or quantifying the specific factors responsible for session-to-session variability.
Reply Q6: We agree that model efficiency is important. However, the cited “~120× fewer parameters” figure in ENIGMA [13] is not relative to our model; it is reported against other prior methods under ENIGMA’s parameter accounting. Our model has approximately 8.5M trainable parameters, which is a moderate parameter footprint rather than a “massive” architecture. This capacity supports the three temporal, spectral, and spatial branches while remaining practical for training and evaluation. Therefore, the characterization of our method as having a “massive parameter footprint” is not correct w.r.t. our model.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Rebuttal Reply Part 1
Dear Area Chair,
We thank the Area Chair and reviewers for their careful review and constructive feedback. We address the comments through additional experiments, analyses, and clarifications below.
C1: We address the main reservations through controlled experiments, multi-subject/multi-seed analyses, statistical testing, protocol clarifications, and refinement of several claims.
C2: We rechecked the cited literature. While SAMGA is relevant concurrent work on THINGS-EEG, it is currently available only as a recent non-peer-reviewed preprint. Similarly, SUPA-EEG is a 2026 course/project submission rather than an established peer-reviewed state-of-the-art publication. Moreover, both suggested preprints appeared shortly before the submission deadline, were released after March 1, 2026, and therefore fall within the NeurIPS 2026 definition of contemporaneous work. S-JEPA, EEGPT, and EEG-DINO concern broader EEG representation learning rather than directly comparable zero-shot THINGS-EEG retrieval, while Brain-JEPA is an fMRI model. We will discuss these works while scoping SOTA to peer-reviewed methods available at submission and novelty to cross-session zero-shot EEG–visual semantic decoding/retrieval.
C3: We distinguish random-seed stability from uniform superiority across subjects. Over five seeds, Top-1 remains 54.8% and Top-5 changes from 85.6% to 85.8%, with small per-subject SDs; within-subject improvements over all baselines are statistically significant. For cross-subject evaluation, we acknowledge that our method does not outperform every baseline for every subject and revise the claim to the highest average cross-subject performance among the compared methods.
C4: We directly address architecture/capacity/loss confounding. A parameter-matched Single-View Transformer has slightly more parameters than ours (8.69M vs. 8.59M) but achieves 48.9/80.1% Top-1/Top-5 versus 54.8/85.6% for ours. Retraining ATM-DWT with the same CPCA/RCR changes performance only from 33.4/61.8% to 33.2/62.3%. These controls support the multiview contribution beyond capacity or regularization.
C5: We will not interpret cross-subject results as uniform superiority. Top-1 of 15.3% remains above the 0.5% chance level and is the highest average among compared methods, while subject-invariant decoding remains an acknowledged limitation. For cross-session evaluation, UBP was selected as the strongest baseline used in our study. Other methods generally do not report this held-out-session protocol and would require modified pipelines; we therefore retain the limited baseline set as an explicit limitation.
C6: We do not claim physically independent neural mechanisms. Cosine/CKA compares the temporal, spectral, and spatial branch embeddings before concatenation and the common final projection, and therefore evaluates redundancy among learned branch representations. We restrict our conclusion to different, relatively non-redundant representations.
C7: Frozen final-layer CLIP is used as a semantic decoding target, not as a model of the cortical visual hierarchy. Fixing it isolates the EEG-encoder contribution and enables fair comparison with prior alignment methods. Intermediate/self-supervised visual targets are complementary future directions; their absence does not invalidate the EEG-side contribution under the fixed target.
C8: RCR acts only on the final task-level semantic representation; it does not constrain raw EEG, ERP components, spectral responses, or intermediate representations to remain invariant. Thus, repetition-related adaptation can persist while the final embedding emphasizes stimulus-consistent information. We do not claim all repetition variability is noise and will identify repetition-stratified analysis as useful future work.
C9: We rechecked the factual/protocol issues: CrossPT-EEG uses supervised cross-time decoding rather than our zero-shot cross-session protocol; Brain-JEPA is fMRI; two EEGPT works were conflated; SUPA-EEG is a 2026 course/project submission; and SAMGA is concurrent non-peer-reviewed work. Cross-subject/session test data are temporally disjoint from training. We also add five-seed results, all-subject ablations, statistical tests, parameter-matched controls, and an equal-loss ATM-DWT control. The detailed results are provided in the reviewer's comment.