Tokenizer-Generator Coupling in Medical Image Generation
Liam Chalcroft
NeurIPS 2026
TL;DR. In a 70-cell low-resolution medical image generation study, the best quantizer changes with the generator, reconstruction quality is a poor selector, and validation-based sampler selection can change the apparent generator ranking.
Abstract. Latent generative models for medical images usually treat the tokenizer as a fixed preprocessing step, with evaluation focused on the generator. This separation was tested in a controlled ChestMNIST study at that crosses discrete tokenizers, generator families and sampler settings on a shared latent grid, alongside continuous-latent reference cells. Rankings were found to depend jointly on all three components, with the best quantizer changing with the generator, and the interaction held when the vocabulary-1024 block was retrained at three seeds, where 4 of 9 pairwise quantizer comparisons exceed three seed standard deviations, including a reversal between LFQ and FSQ from MaskGIT to D3PM. Reconstruction quality was not a reliable guide to generation quality. Sampler settings also changed the conclusions, since validation-selected retuning of D3PM and SEDD on LFQ-1024 reduced FID-192 from 0.44 and 0.41 to 0.09 and 0.10 at lower NFE, replicated across seeds, bringing both close to the strongest continuous references. FID-192 is used as an internal ranking metric and agrees with standard FID-2048 (Spearman 0.89) and with a label-free two-sample test (0.86). The results fit a rate-distortion-modelability tradeoff in which modelability depends on the generator, sampler and inference budget. The scope is limited to 54 discrete and 16 continuous cells on low-resolution medical-style images, with unconditional generation, non-clinical FID-based evaluation and single-seed training outside the seeded block.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:50 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper presents a controlled empirical study of tokenizer-generator-sampler coupling in low-resolution medical image generation. The reviewers generally found the paper clearly written, technically careful, and valuable as an empirical study, while also raising several important concerns, including limited novelty, limited external validity, reliance on single-seed evaluation, and the use of non-standard FID-192 as the primary metric.
The main weaknesses are as follows. First, the experimental scope is limited: the primary setting is 64 x 64 ChestMNIST, and the cross-dataset replication is also limited. This setting is appropriate for controlled analysis, but it does not support broad conclusions about high-resolution or clinically realistic medical image generation. Second, the original full experimental grid remains largely single-seed. The authors added multi-seed evidence for the vocabulary-1024 block in the rebuttal, but this is not equivalent to a full multi-seed replication of the entire 54-cell design. Therefore, the exact variance-decomposition values and some fine-grained rankings should be interpreted as descriptive rather than inferential. Third, the use of FID-192 remains a limitation. The FID-2048 comparison added after the rebuttal is reassuring at the level of broad trends, but some closer AR/MaskGIT rankings are sensitive to the evaluation metric. Finally, the medical-image-generation framing should remain narrow: the work does not demonstrate clinical utility, pathology-conditional generation, radiologist evaluation, or downstream augmentation benefit.
Nevertheless, the rebuttal substantially strengthens the case for acceptance. The authors directly addressed the most important reviewer concerns with additional experiments rather than only textual clarification. They added three-seed validation for a representative vocabulary-1024 block, showing that the key tokenizer-generator interaction is larger than the observed seed variation in the main comparisons. They also repeated validation-based sampler selection for D3PM and SEDD across seeds, supporting the claim that default sampler settings may substantially underestimate the performance of these models. In addition, they compared FID-192, FID-2048, and a classifier two-sample test, acknowledged and corrected the overstatement that FID-2048 degenerates at this resolution, and appropriately narrowed claims where metric or seed sensitivity remains.
The core contribution of the paper is that, in a low-resolution medical-style benchmark, it uses a matched factorial design to show that tokenizer, generator, and sampler choices interact, making independent component ranking unreliable. This provides practical guidance for system design: tokenizer selection should be evaluated jointly with the downstream generator and sampler, rather than decided solely from reconstruction metrics. The neighbour-conditional predictive gain analysis added in the rebuttal is also a useful preliminary attempt to characterize tokenizer modelability, although it should be presented as exploratory given the small number of tokenizer configurations.
Overall, I find this submission technically solid, honest about its limitations, and meaningfully strengthened by the rebuttal. Although its scope and generality remain limited, the controlled experimental design and post-rebuttal robustness checks make its empirical contribution sufficiently valuable for the conference. I recommend acceptance, with the expectation that the camera-ready version clearly narrows the claims, labels the variance decomposition as descriptive, reports the FID-2048 comparison, and avoids overclaiming clinical relevance or universal tokenizer rankings.
Final justification
My final justification for the recommendation is provided in the meta-review above, taking into account the reviews, author response, and reviewer discussion.
Read meta-review
Meta-review
This paper presents a controlled empirical study of tokenizer-generator-sampler coupling in low-resolution medical image generation. The reviewers generally found the paper clearly written, technically careful, and valuable as an empirical study, while also raising several important concerns, including limited novelty, limited external validity, reliance on single-seed evaluation, and the use of non-standard FID-192 as the primary metric.
The main weaknesses are as follows. First, the experimental scope is limited: the primary setting is 64 x 64 ChestMNIST, and the cross-dataset replication is also limited. This setting is appropriate for controlled analysis, but it does not support broad conclusions about high-resolution or clinically realistic medical image generation. Second, the original full experimental grid remains largely single-seed. The authors added multi-seed evidence for the vocabulary-1024 block in the rebuttal, but this is not equivalent to a full multi-seed replication of the entire 54-cell design. Therefore, the exact variance-decomposition values and some fine-grained rankings should be interpreted as descriptive rather than inferential. Third, the use of FID-192 remains a limitation. The FID-2048 comparison added after the rebuttal is reassuring at the level of broad trends, but some closer AR/MaskGIT rankings are sensitive to the evaluation metric. Finally, the medical-image-generation framing should remain narrow: the work does not demonstrate clinical utility, pathology-conditional generation, radiologist evaluation, or downstream augmentation benefit.
Nevertheless, the rebuttal substantially strengthens the case for acceptance. The authors directly addressed the most important reviewer concerns with additional experiments rather than only textual clarification. They added three-seed validation for a representative vocabulary-1024 block, showing that the key tokenizer-generator interaction is larger than the observed seed variation in the main comparisons. They also repeated validation-based sampler selection for D3PM and SEDD across seeds, supporting the claim that default sampler settings may substantially underestimate the performance of these models. In addition, they compared FID-192, FID-2048, and a classifier two-sample test, acknowledged and corrected the overstatement that FID-2048 degenerates at this resolution, and appropriately narrowed claims where metric or seed sensitivity remains.
The core contribution of the paper is that, in a low-resolution medical-style benchmark, it uses a matched factorial design to show that tokenizer, generator, and sampler choices interact, making independent component ranking unreliable. This provides practical guidance for system design: tokenizer selection should be evaluated jointly with the downstream generator and sampler, rather than decided solely from reconstruction metrics. The neighbour-conditional predictive gain analysis added in the rebuttal is also a useful preliminary attempt to characterize tokenizer modelability, although it should be presented as exploratory given the small number of tokenizer configurations.
Overall, I find this submission technically solid, honest about its limitations, and meaningfully strengthened by the rebuttal. Although its scope and generality remain limited, the controlled experimental design and post-rebuttal robustness checks make its empirical contribution sufficiently valuable for the conference. I recommend acceptance, with the expectation that the camera-ready version clearly narrows the claims, labels the variance decomposition as descriptive, reports the FID-2048 comparison, and avoids overclaiming clinical relevance or universal tokenizer rankings.
Final justification
My final justification for the recommendation is provided in the meta-review above, taking into account the reviews, author response, and reviewer discussion.
2 comments
Closing summary for the AC and PCs
Thank you again to the AC and reviewers for the time spent on the paper and discussion. Since the meta-review was written before the additional experiments, we wanted to leave a brief summary of what changed before the discussion closes. We have responded to each question in the individual threads, including the experiments we could not complete.
We agree that the observation that reconstruction quality does not predict generation quality is already established in natural-image work. We will cite that work directly and will not present this observation alone as the novelty of the paper. The additional result from the discussion is a generator-free statistic, neighbour-conditional predictive gain, which separates the tokenizer families in the current nine-tokenizer analysis with rank-AUC 1.00, whereas reconstruction PSNR has Spearman correlation +0.01 and marginal token entropy has rank-AUC 0.50. Given the small sample, we will present this as an initial result rather than a general measure of tokenizer modelability.
We also believe the matched factorial supports a more specific contribution: tokenizer, generator, and sampler choices are not separable. The best quantizer changes with the generator, and validation-based sampler selection can change the apparent generator ranking. We are not aware of prior work that studies this full interaction in one matched design, although the individual observations are clearly related to earlier natural-image results.
The evidence for this claim is now stronger than in the submitted paper. We retrained the vocabulary-1024 interaction block using three seeds, all evaluated on the same GPU. Six of the nine pairwise quantizer comparisons are larger than three times the pooled standard deviation. We have also identified the three comparisons that remain within seed variation and will no longer claim those orderings. The exact variance-decomposition percentages in Table 3 remain descriptive because they were calculated from the single-seed full grid; the seeded subset supports the qualitative interaction, not the precise percentage shares.
We also repeated the full validation-based sampler-selection procedure for D3PM and SEDD at all three seeds. The tuned mean FID-192 values are 0.113 and 0.112, compared with defaults of 0.44 and 0.41, corresponding to mean improvements of 3.9x and 3.7x. The selected setting varies between seeds, but the improvement is present in every case. The revised claim will therefore concern validation-based selection for each trained model, not transfer of one fixed sampler setting between seeds.
For the metric concern, FID-192 and standard FID-2048 have Spearman correlation 0.80 across 12 cells, and a classifier two-sample test agrees with FID-192 at Spearman 0.78. Looking at the individual vocabulary-1024 cells, the structural interaction remains under FID-2048. In particular, the D3PM ordering is identical under both metrics, LFQ < FSQ < VQ, and VQ is weakest under both AR and D3PM. Some closer AR and MaskGIT orderings change between metrics or fall within seed variation, so we will treat those specific orderings as unresolved rather than claiming a winner.
The standard-FID analysis also showed that Appendix C is wrong to describe FID-2048 as degenerate at 64 x 64. Its real-versus-real floor at 10,000 samples is 2.31, with no negative values across 20 resamples. We will correct this and present FID-192 as a lower-dimensional internal metric whose broad ranking agrees with standard FID, not as a necessary replacement.
Finally, we tested whether the PneumoniaMNIST reversal could be explained simply by training-set size. Subsampling ChestMNIST to 4,700 examples did not cause VQ to overtake LFQ, so sample count alone is not the explanation. This does not establish the cause of the reversal, and we still lack the requested natural-image and higher-resolution replications. We will therefore restrict the claims to the low-resolution medical-style setting tested and retain external validity and clinical utility as limitations.
We think the revised paper is more narrowly framed and better supported than the submitted version: it establishes the tokenizer–generator interaction within the seeded block, shows that validation-based sampler selection is robust across seeds, reports an initial generator-free statistic related to modelability, and gives a practical recommendation to evaluate the tokenizer jointly with the generator and sampler rather than selecting it from reconstruction alone. We are grateful to the reviewers for the comments that led to these experiments and revisions, and we would welcome reconsideration in light of the discussion.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The work shows how tokenizers affect latent medical image generation. The authors argue that tokenizers influence downstream generative performance. Notably, the authors use a controlled factorial design on ChestMNIST to compare various discrete (VQ, LFQ, FSQ) and continuous (VAE/AE) tokenizers across different vocabulary sizes, generators, and sampling budgets (keeping other factors constant). They present a rate–distortion–modelability perspective, showing that reconstruction quality alone is not sufficient for selecting a tokenizer. The experiments show that the choice of tokenizer is a key factor in generation quality. LFQ stands out as the strongest default discrete tokenizer, and the tokenizers that provide the best reconstructions do not always produce the best generated images.
Strengths and weaknesses
Strengths:
- The paper addresses an overlooked aspect of latent generative modeling by properly studying the impact of tokenizer choice on downstream generation quality.
- The experimental design is very elaborate. For example, it contains matched encoder-decoder architectures, latent grid sizes, vocabulary sizes, and evaluation protocols.
- The study factorizes the effects of tokenizer family, generator family, vocabulary size, and sampler budget as a result reader gets empirical insights of the work.
- The evaluation setup is well chosen, for example, bootstrap confidence intervals, domain-feature validation, cross-dataset replication, and memorization analysis.
Weaknesses:
- The study is limited to relatively low-resolution benchmark datasets. This makes it unclear whether the conclusions generalize to higher resolution. Also, the performance under clinically realistic medical imaging settings is needed to be explored.
- This question may be out of scope for the current work; however, it is still worth exploring the theoretical understanding behind why certain tokenizers, such as LFQ, lead to more modelable latent spaces.
- The authors defined modelability through downstream generation metrics (primarily FID). The paper does not provide a direct measure or analysis of latent-space complexity.
- The practical implications for downstream medical applications are not explored; it is not very clear whether the observed tokenizer preferences translate to improvements in tasks such as diagnosis, segmentation, or data augmentation.
Questions
- The study is performed on relatively low resolution benchmark datasets. Do the authors expect the same tokenizer rankings to hold for higher resolution medical images? Some results on this would help understand how broadly the conclusions may apply.
- Readers may get curious about why LFQ appears to produce more modelable latent spaces than the other tokenizers. Some qualitative intuition could help explain this behavior.
- Modelability is measured through downstream generation quality. Are there any latent-space statistics that seem to correlate with modelability?
- Some discussion on this limitation would be useful. How dependent are the conclusions on the particular generators and samplers used in the study?
- It would be interesting to know whether the tokenizer rankings are also reflected in classification, segmentation, or data augmentation. This would strengthen the practical relevance of the work.
Limitations
Yes. Check questions and weaknesses sections for missing critical points from the submitted manuscript.
Final justification
A lot (but not all) of my concerns have been addressed. I am upgrading my score to Borderline Accept.
Formatting concerns
N/A
1 comment
Rebuttal
Thank you for the careful reading and constructive comments. We used the discussion period to run additional analyses addressing the main points in the review. Unless stated otherwise, the results below were obtained after submission.
For the questions about modelability, we tested whether a generator-free statistic of the token field is associated with downstream generation quality. For each discrete tokenizer, we measured marginal entropy, variation in entropy across spatial positions, and neighbour-conditional predictive gain. The last quantity measures how much knowing the token immediately to the left or above reduces uncertainty about the current token. Bigram counts are fitted on the training split and evaluated using held-out cross-entropy on the test split, so a sparse table that memorises the training data is penalised. The smoothing parameter is selected on validation data without using FID.
Using rank-AUC to separate the three VQ tokenizers from the six LFQ and FSQ tokenizers gives:
| Statistic | Rank-AUC |
|---|---|
| Neighbour-conditional predictive gain | 1.000 |
| Reconstruction PSNR | 0.611 |
| Marginal token entropy | 0.500 |
The predictive-gain result is the same for left and upper neighbours using validation-selected smoothing.
Marginal entropy does not support the explanation given in the submission. VQ lies between LFQ and FSQ on that measure, so marginal entropy alone separates the families no better than chance. Neighbour-conditional predictive gain does separate them in this analysis.
The result is consistent with local dependence being more relevant than marginal entropy alone. LFQ produces high-entropy tokens with relatively weak dependence on neighbouring positions, while VQ's learned codebook produces stronger spatial structure. Different generators may handle this structure differently, which would be consistent with the quantizer–generator interaction in the paper. This is an interpretation of the result, not something established by the current sample.
There are only nine tokenizers in this analysis, so we will treat it as a small-sample, family-level result and will not report p-values. We also do not consider the exact ordering within each family reliable, since some FID differences are around 0.04, smaller than the seed variation measured elsewhere. The claim supported by the current analysis is that neighbour-conditional predictive gain separates the broad tokenizer families better than reconstruction PSNR or marginal entropy.
We could not run the requested higher-resolution experiment during the discussion period. We do not have tokenized data at 128 or 224 pixels, and retokenizing and retraining at four times the token count was not feasible in the available window. We will limit the claims to low-resolution medical-style images.
We did test whether training-set size explains the change in tokenizer ranking between ChestMNIST and PneumoniaMNIST. When ChestMNIST is subsampled to 4,700 examples, LFQ+AR still outperforms VQ+AR, with FID-192 of 0.946 versus 2.023. The cross-dataset result is therefore not explained by sample count alone. A matched non-medical replication and a higher-resolution experiment remain important follow-up work.
The dependence on the chosen generators and samplers is part of the result. The factorial analysis shows that generator rankings change across tokenizer families, with the quantizer–generator interaction accounting for 18.8% of the observed variation. Sampler selection can also change the apparent generator ranking.
The conclusion is therefore conditional on the generators and samplers tested. This means that the components cannot be selected independently; it does not mean that the current experiment establishes the same interaction for every possible generator. We checked whether the interaction survives training variation by retraining the vocabulary-1024 block at three seeds. Six of the nine pairwise quantizer comparisons are larger than three times the pooled standard deviation, including the comparisons that establish the interaction.
For the downstream classification and augmentation question, the current generators are unconditional and do not produce images with pathology labels. A direct synth-then-classify experiment would therefore require labels to be assigned after generation, making the result difficult to interpret.
We instead ran a classifier two-sample test in which a discriminator distinguishes real from generated images. Across 12 cells and three seeds, its ranking agrees with FID-192 at Spearman 0.78. The test does not use Inception features or a Gaussian approximation and is consistent with the domain-feature FID agreement of 0.943 already reported in the paper.
The best model, AE+RF, gives discriminator AUC 0.55, so the classifier is only slightly better than chance at separating its samples from real images. Poor models give AUC values close to 1.0, in line with their FID results.
This is not a test of clinical utility. A direct utility study would require pathology-conditional generation followed by training or augmenting a classifier with synthetic images carrying valid labels. We will state this as future work rather than presenting the two-sample test as an answer to the clinical utility question.
The predictive-gain analysis does not settle the broader question of modelability, but it provides a generator-free statistic that is associated with the tokenizer-family differences observed in this study.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This work is an empirical study rather than a new method. It tries to answer whether the common practice of treating the tokenizer as fixed preprocessing and only tuning the generator is valid for medical image generation task. Using a controlled factorial grid on chestmnist at 64x resolution (where 54 discrete cells crossing multiple tokenizers, three vocabulariy sizes and six generators, plus 16 continuous VAE references), they show that tokenizer, generator and sampler cannot be ranked independently. They show that reconstruction quality measured by PSN is a misleading criterion for picking a tokenizer and that re-tuning the sampler can invert the apparent rankings.
Strengths and weaknesses
Overall this is a clean and honest study and I like the execution. But the findings are not new enough and the evidence base is a bit too thin for Neurips caliber to land above borderline. I am open to moving up if the authors address my concerns.
The question is a good one and it is defininetly not explored in medical imaging where most pipelines occupy a narrow corner of the design space and cannot separate the "generator is strong" from "tokenizer made an easy distribution" from "the sampler is well tuned". A controlled grid that isolating these is a useful contribution. My hesitation is that the medical angle is thin in practice and this is chestmnist at 64x resolution which is barely medical in any clinically meaninggful sense, and the paper is upfornt that it cannot settle clinical generation. So the significance is okay.
The headline findings of reconstruction does not predict generation quality and that the tokenizer/generator/sampler interact are already established in the natural image litreature that the paper itself cites. So the contribution is mostly confirmation on a new domain rather than a new insight, and the medical specific approach of the conclusions is not strongly demonstrated beyond chestmnist. That keeps originality a bit low for me.
The factorial design is well controlled which looks strong. The scope limits are stated plainly which is also nice. But the central evidence rests on a single training seed per cell, which the authors acknowledged and which makes the variance decomposition in Tab. 3 descriptive rather than inferential. For a paper its entire value is in the reliability of its rankings, this is a weakness. I simply can't tell whether the non-separable claim and the fine grained inversions survive the seed noise. The re-tuning result that drps d3pm to 0.09 is helping the narrative and appears to rest on one revalidated cell so it would help to know it is not a single lucky run. FID-192 also a nonstandard metric, defensible as an internal ranking tool given the real vs real floor of 0.01 and the domain FID check, but it is one more thing that makes the absolute numbers hard to compare to anything outside this paper.
Well organized paper with clear writing, no problems here.
Summarizing, this is a well executed study of a question that is mostly answered in natural image domain with an evidence base (e.g. one seed, one core dataset, low res, proxy metric etc.) too thin for me to treat the findings as durable/important. That being said, I like the design and I am willing to increase my score given that the authors' claims were shown to hold across seeds/datasets etc.
Questions
- Can you rerun at least the headline cells (the ones that are holding the not-separable claim and the variance decomposition) across multiple seeds? So that we can see the key fid differences are large relative to seed noise and not just bootstrap noise on one run?
- The d3pm/sedd re-tuning result is central to the sampler-cant-invert-rankings claim. Is this revalidated cell a single run, and does the improvement hold across seeds? This number is somewhat convincing and I'd love to believe it :)
- How much of this is medical-specific versus a general property? A small replication of one or two key interactions on a non-medical 64x dataset would tell us wherher the conclusions are about medical images or just about tokenizers in general.
- fid-192 is a nonstandard technique. So beyond the domain-fid spearman check, can you show that at least the coarse regime rankings are stable under standard fid-2048 on a few cells?
Limitations
The authors are fully upfront about scope and I appreciate it. The two I would still push on are the single seed deisgn and the medical framing is stronger than what is demonstrated since chestmnist at 64x does not really exercise the clinically subtle variation the intro motivates so the claims should be scoped to low resolution medical-style images perhaps? (rather than medical generation broadly)
Final justification
The rebuttal addressed most of my main concerns, so I am updating my rating to borderline accept!
-
Seed robustness: My biggest concern was that the main interaction results were based on one training seed per cell. The new three-seed experiments on the vocabulary-1024 block are convincing enough for the qualitative claim that tokenizer and generator cannot be selected independently. The main differences are substantially larger than the observed seed variation, while the authors appropriately avoid claiming the few comparisons that remain within the noise.
-
Sampler tuning: The repeated D3PM/SEDD tuning experiments also address my concern that the large improvement might have been a lucky run. Validation-based sampler selection improves both models across all three seeds. I think the revised paper should keep the claim at this level rather than implying that one fixed sampler configuration transfers between runs.
-
FID-192: The standard FID-2048 comparison is reassuring. The exact ordering of some close AR/MaskGIT cells changes, but the main structural conclusion that the preferred tokenizer depends on the generator still holds. I also appreciate that the authors will correct the claim that FID-2048 is degenerate at this resolution.
Remaining limitations: The full factorial grid is still largely single-seed, so the exact variance-decomposition percentages should remain descriptive rather than inferential. The study is also limited to low-resolution medical-style images, and the requested natural-image / higher-resolution replication was not completed. I view these as limitations on generality rather than problems with the narrower claims now being made.
Overall, the paper is still more of a careful empirical study than a novel method, and its broader medical significance is limited by the low-resolution setting. However, the additional experiments substantially strengthen the reliability of the main finding, and the authors have appropriately narrowed the claims where the evidence is weaker. I therefore lean toward acceptance.
Formatting concerns
N/A
3 comments
Rebuttal
Thank you for the careful reading and constructive comments. We used the discussion period to run additional experiments addressing the main points in the review. Unless stated otherwise, the results below were obtained after submission.
For the seed question, we retrained the vocabulary-1024 block, {VQ, LFQ, FSQ} x {AR, MaskGIT, D3PM}, together with SEDD on LFQ, using seeds 42, 43, and 44. Every run was evaluated on the same GPU.
| Cell | Seed 42 | Seed 43 | Seed 44 | Mean | SD |
|---|---|---|---|---|---|
| VQ + AR | 2.10 | 2.21 | 1.93 | 2.08 | 0.118 |
| VQ + MaskGIT | 1.41 | 1.86 | 1.68 | 1.65 | 0.184 |
| VQ + D3PM | 1.55 | 1.52 | 1.50 | 1.53 | 0.019 |
| LFQ + AR | 0.34 | 0.34 | 0.49 | 0.39 | 0.070 |
| LFQ + MaskGIT | 1.90 | 1.86 | 1.99 | 1.92 | 0.052 |
| LFQ + D3PM | 0.42 | 0.40 | 0.36 | 0.39 | 0.022 |
| FSQ + AR | 0.40 | 0.86 | 0.44 | 0.57 | 0.207 |
| FSQ + MaskGIT | 1.15 | 1.14 | 1.17 | 1.15 | 0.012 |
| FSQ + D3PM | 1.19 | 1.15 | 1.25 | 1.20 | 0.042 |
| LFQ + SEDD | 0.41 | 0.42 | 0.48 | 0.44 | 0.032 |
The median standard deviation across cells is 0.047. D3PM and SEDD are relatively stable, with standard deviations of 0.02–0.04. AR and MaskGIT vary more, with standard deviations of 0.05–0.21. The main outlier is FSQ+AR at seed 43, which gives 0.86 compared with approximately 0.42 at the other two seeds.
The quantizer–generator interaction remains in this block. LFQ is best under AR and D3PM, both with mean FID 0.39. Under MaskGIT, FSQ is best at 1.15 and LFQ is worst at 1.92. Six of the nine pairwise quantizer comparisons are larger than three times the pooled standard deviation. These include FSQ versus LFQ under MaskGIT, where the gap is 0.77, and LFQ versus VQ under AR and D3PM, where the gaps are both greater than 1.1.
Three comparisons remain within seed variation: VQ versus LFQ and VQ versus FSQ under MaskGIT, and LFQ versus FSQ under AR. For the last comparison, the mean gap is 0.18 while the three-standard-deviation threshold is 0.65, partly because of the FSQ+AR outlier. We will not claim an ordering for these comparisons. The seeded analysis covers the vocabulary-1024 block; the rest of the 18-cell grid is still based on one seed.
For D3PM and SEDD, we repeated the complete tuning procedure separately at seeds 42, 43, and 44. For each trained model, the sampling grid was evaluated on the validation split using 2,000 generated samples. The selected configuration was then evaluated once on the test split using 10,000 samples.
| Cell | Seed 42 | Seed 43 | Seed 44 | Mean | Default | Improvement |
|---|---|---|---|---|---|---|
| LFQ + D3PM | 0.090 | 0.151 | 0.099 | 0.113 | 0.44 | 3.9x |
| LFQ + SEDD | 0.098 | 0.113 | 0.126 | 0.112 | 0.41 | 3.7x |
The improvement is present at every seed. Relative to the 1000-step default, the per-seed gain ranges from 2.6x to 4.9x. The exact selected configuration changes between seeds, but tuning improves the result in every case.
There is a difference between repeating the selection procedure and transferring one fixed setting between trained models. Applying the 100-step configuration selected at seed 42 directly to seed 43 gives FID-192 of 0.34. Our protocol instead selects the sampler configuration on validation data separately for each trained model. The supported claim is therefore that the standard 1000-step setting understates D3PM and SEDD performance, while validation-based sampler selection improves both models across seeds.
We also rebuilt the lost training environment from the lockfile. The default result changes from 0.44 to 0.4275 and the tuned result from 0.0898 to 0.0885. This approximately 2% proportional shift does not affect the result. All seeded runs were evaluated in the same rebuilt environment.
On the medical-specific question, the individual observations are not specific to medical images. Natural-image work, including Yu et al. (2024), Yao et al. (2025), VTBench, and TokBench, has already shown that tokenizer choice affects generation and that reconstruction is not a sufficient selection criterion. We will make this clearer.
What our experiment adds is a matched design in which the best quantizer changes with the generator and sampler selection changes the apparent generator ranking. We are not aware of prior work that measures this full interaction in the same controlled grid. Our evidence comes from low-resolution medical data, but we will not claim that the interaction is uniquely medical.
We also tested whether the change between ChestMNIST and PneumoniaMNIST was caused by the smaller PneumoniaMNIST training set. Subsampling ChestMNIST to 4,700 examples does not cause VQ to overtake LFQ: LFQ+AR gives 0.946 and VQ+AR gives 2.023. LFQ remains better at every tested ChestMNIST size. This rules out the simple sample-count explanation, but it does not identify the cause of the PneumoniaMNIST reversal.
We could not add a matched natural-image replication during discussion because the current pipeline does not include the 2D tokenizer-training path needed to train a new set of matched tokenizers. We will limit the current claims to the setting tested rather than using the absence of that experiment to claim medical specificity.
Finally, we computed FID-2048 and FID-192 from the same generated samples for 12 cells spanning FID-192 values from 0.07 to 8.44. Their Spearman correlation is 0.80. Both metrics identify AE+RF, tuned LFQ-D3PM, and the VAE references as strong models and agree on the broad poor-performing group. They differ in some of the fine ordering within that group, but the paper's conclusions do not depend on those differences.
A classifier two-sample test also agrees with FID-192 at Spearman 0.78. This test does not use Inception features or a Gaussian approximation.
The FID-2048 experiment also showed that the claim in Appendix C that standard FID is degenerate at 64 x 64 is incorrect. At 10,000 samples, the real-versus-real floor is 2.31, with standard deviation 0.016 and no negative values across 20 resamples. We will correct Appendix C and describe FID-192 as a lower-dimensional internal metric rather than a necessary substitute for standard FID.
We agree that ChestMNIST at 64 x 64 does not capture the full difficulty of clinically meaningful image generation. The claims will be limited to low-resolution medical-style images.
The additional experiments support the interaction and tuning result across seeds, while also giving a clearer boundary on what the current study can claim.
Answer to rebuttal
Thank you for the detailed rebuttal. The multi-seed experiments mostly address my concern about whether the tokenizer generator interaction and the D3PM/SEDD tuning improvements are robust to seed variation. In particular, the reversal between LFQ and FSQ under AR/D3PM versus MaskGIT appears way larger than the observed seed variation which seem convincing, I also appreciate the clarification that sampler settings are selected separately on the validation set for each trained model. I think the claim that validation based sampler selection consistently improves both models, rather than one fixed sampler configuration transferring across seeds is great and should be reflected clearly in the revised paper. The medical-specific concern is also clearer now. I appreciate that the authors do not claim that the observations are unique to medical imaging and will limit the empirical claims to the low-resolution medical setting tested here. The ChestMNIST subsampling experiment is useful for ruling out dataset size as the simple explanation for the PneumoniaMNIST reversal, although it does not replace the requested natural-image replication. I view this primarily as a remaining limitation on external validity rather than a problem with the supported claims, so no problems there.
I have two remaining questions:
- The seeded experiments support the existence of a tokenizer-generator interaction within the vocabulary-1024 block, but Table 3’s exact variance-decomposition percentages are still based on the full single-seed grid. Do the authors plan to present these percentages only as descriptive results and avoid implying that their precise magnitudes are statistically established? I think the multi-seed subset now supports the qualitative interaction claim, but not necessarily the exact quantitative decomposition across the complete grid.
- For the 12-cell FID-2048 comparison, could the authors provide the individual FID-192 and FID-2048 values, or at least confirm whether the central tokenizer-generator reversals are preserved under FID-2048? A Spearman correlation of 0.80 and agreement on the broad regimes are reassuring, but it would be useful to know whether the interaction underlying the main claim is also visible under the standard metric.
Thank you for the follow-up. We agree with both remaining points and have revised the scope of the claims accordingly.
For Table 3, the variance decomposition should be treated as descriptive of the observed full grid. The three-seed subset supports the qualitative conclusion that quantizer and generator are not separable, but it does not make the exact 38.7%, 18.8%, and 17.0% shares inferential. Those percentages were calculated from the single-seed full grid, so we will label them as descriptive and will not attach statistical significance to their precise values.
We also computed FID-192 and FID-2048 on the same 10,000 generated images for the nine vocabulary-1024 interaction cells:
| Generator | Quantizer | FID-192 | FID-2048 |
|---|---|---|---|
| AR | VQ | 2.15 | 192.4 |
| AR | LFQ | 0.34 | 52.0 |
| AR | FSQ | 0.42 | 35.4 |
| MaskGIT | VQ | 1.41 | 295.5 |
| MaskGIT | LFQ | 1.91 | 78.3 |
| MaskGIT | FSQ | 1.15 | 195.1 |
| D3PM | VQ | 1.55 | 238.5 |
| D3PM | LFQ | 0.44 | 42.4 |
| D3PM | FSQ | 1.14 | 59.3 |
The main conclusion still holds under FID-2048: the quantizer ranking depends on the generator. Under FID-2048, FSQ is best with AR, while LFQ is best with MaskGIT and D3PM. There is therefore no single quantizer ranking that applies across generators.
The clearest interaction is the D3PM row, where both metrics give the same ordering:
LFQ < FSQ < VQ
The gaps are also large under both metrics. FID-192 gives 0.44, 1.14, and 1.55, while FID-2048 gives 42.4, 59.3, and 238.5. VQ is also the weakest quantizer under both AR and D3PM for both metrics.
Some of the finer orderings are not stable. Under AR, LFQ is slightly better than FSQ under FID-192, while FSQ is better under FID-2048. This is already one of the comparisons that falls within seed variation: the mean gap is 0.18, compared with a three-standard-deviation threshold of 0.65. We therefore do not claim an ordering between LFQ and FSQ under AR.
The MaskGIT row is also metric-dependent. FID-192 favours FSQ, while FID-2048 favours LFQ. These cells are all in the relatively poor FID-192 range of 1.15–1.91, and their ordering is sensitive to both training seed and feature representation. We will therefore treat the MaskGIT ordering as unresolved.
The revised claim will be at the level supported by both analyses. The structural interaction is robust: the preferred quantizer changes with the generator under both FID-192 and FID-2048. The large D3PM differences are stable across metrics, and VQ remains weakest under AR and D3PM. We will not make claims about the exact ordering of the closer AR and MaskGIT cells, where neither the seed analysis nor the metric comparison gives a stable answer.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only, Major Concern: Improper research involving human subjects
Read review
Summary
This paper systematically investigates the coupling effect between tokenizers and generators in medical image generation. The authors construct a large-scale factorial experimental grid on ChestMNIST (64×64), covering 3 discrete quantizers (VQ/LFQ/FSQ) × 3 vocabulary sizes × 6 discrete generators, plus 16 continuous reference cells, totaling 70 experimental units. Key findings include: (1) Strong interaction effects between tokenizer and generator (interaction terms explain 33% of variance), rendering independent evaluation invalid; (2) Reconstruction quality (PSNR) fails to predict generation quality (FID), with Spearman correlation near zero; (3) Sampling budget (NFE) can invert generator rankings—D3PM/SEDD improve from FID 0.44/0.41 to 0.09/0.11 when tuned from default 1000 steps to 100–500 steps; (4) A "rate–distortion–modelability" triadic tradeoff framework is proposed. The paper provides extensive ablations, cross-dataset replication (PneumoniaMNIST/OrganAMNIST), bootstrap confidence intervals, and memorization probes.
Strengths and weaknesses
Strengths
- Rigorous and comprehensive experimental design: The $$ full factorial design + 16 continuous reference cells covers the vast majority of current mainstream discrete quantizers and generators, demonstrating substantial workload.
- Methodologically valuable core finding: The conclusion that "tokenizer and generator cannot be evaluated independently" challenges the prevailing two-stage paradigm in medical image generation, offering significant engineering guidance.
- Compelling counter-intuitive findings: The near-zero correlation between reconstruction PSNR and generation FID ($$ for the discrete panel) clearly and powerfully supports the central thesis, raising a valid challenge to the field's common practice of selecting tokenizers based on reconstruction metrics alone.
- Rich analytical dimensions: Beyond the main experiments, the paper includes sampling tuning (Figure 1), cross-dataset replication (Table 6), memorization probing (Figure 6), inpainting demonstrations (Figure 7), and counterfactual analysis (Figure 8), making the discourse dense and multi-faceted.
- Well-written with clear self-positioning: The authors repeatedly emphasize the study's limitations (low resolution, single seed, non-clinical evaluation) without over-claiming, demonstrating good scholarly conduct. Weaknesses
- Limited novelty: Similar findings have already been reported in the natural image domain (e.g., MAGVIT-v2, FSQ, Dieleman 2025 blog). The main contribution is the systematic transplantation and empirical validation of these observations to the medical image domain, lacking methodological breakthroughs.
- Fundamental statistical inference flaw: The variance decomposition in Table 3 is built on only one training run per cell, making it impossible to estimate variance due to training stochasticity. The percentages are purely descriptive and cannot be subjected to any significance testing. While the authors acknowledge this, it substantially weakens the statistical persuasiveness of the conclusions.
- Limited external validity due to single dataset and resolution: Although replication experiments on two additional datasets are provided, they only cover 6 headline cells. The fact that PneumoniaMNIST results invert the ChestMNIST ranking (VQ wins instead of LFQ) suggests that conclusions are highly sensitive to data scale and distribution, severely restricting generalizability.
- Asymmetric hyperparameter tuning: The authors aggressively tune D3PM/SEDD (from 1000 steps down to 100–500) in Table 4, but appear less aggressive in tuning AR and MaskGIT. While the authors claim a sweep was conducted, the reported improvement for AR is only 0.33→0.31, far smaller than D3PM's gain. This may create an impression that D3PM/SEDD are over-credited.
- Controversial FID-192 metric: The authors justify using FID-192 over standard FID-2048 for numerical stability, but this means the reported FID values cannot be directly compared with any external literature. Although the Domain-FID sanity check ($$) demonstrates internal consistency, it does not establish external comparability.
Questions
- The variance decomposition in Table 3 relies on a single run per cell. If 3–5 runs with different seeds were performed per cell and averaged, would the interaction share change significantly? Have the authors considered a small-scale seed-variance estimation (e.g., on 3–5 representative cells) to demonstrate the stability of single-run results?
- All experiments are conducted at 64×64 resolution. Would the tokenizer-generator interaction pattern change at higher resolutions (e.g., 256×256 or 512×512)? In particular, AR generators face quadratic complexity growth with larger token grids—would their advantage still hold?
- FID-192 is used as the primary metric, but its values are not comparable to standard FID-2048. Have the authors attempted to report standard FID-2048 for a subset of representative cells (even if unstable) to provide readers an "anchor" for assessing absolute generation quality?
- In the cross-dataset replication, VQ-1024+AR outperforms LFQ-1024+AR on PneumoniaMNIST. How do the authors interpret this reversal? Does this suggest that LFQ's high-entropy advantage becomes a disadvantage on smaller datasets (potentially due to overfitting)?
Limitations
The authors have adequately enumerated limitations in Section 5, including:
- Low resolution (64×64), single primary dataset, limited external validity
- Single training seed, no estimation of training stochasticity
- FID-192 being non-standard and incomparable with external literature
- Unconditional generation, no pathology conditioning
- No clinical evaluation (no radiologist assessment, no synth-then-classify utility study)
- Hyperparameter tuning only revalidated at 10K samples for two LFQ configurations; the rest use 2K screening estimates The limitations are comprehensively stated but no mitigation strategies are proposed, which feels somewhat passive.
Formatting concerns
No format errors were found here.
1 comment
Rebuttal
Thank you for the careful reading and constructive comments. We used the discussion period to run additional experiments addressing the main points in the review. Unless stated otherwise, the results below were obtained after submission.
The tuning sweep was not asymmetric, although the paper made it easy to read it that way because we did not add up the grid sizes. The grids reported in Appendix D were:
| Generator | Grid | Number of configurations |
|---|---|---|
| MaskGIT | 5 x 6 x 2 | 60 |
| BFN | 6 x 5 | 30 |
| DFM | 5 x 5 | 25 |
| D3PM | 5 x 4 | 20 |
| SEDD | 5 x 4 | 20 |
| AR | 6 x 3 | 18 |
D3PM and SEDD therefore had the second-smallest grids, while MaskGIT had the largest. AR moved little because its default FID of 0.33 was already fairly close to the continuous-reference range of 0.07–0.14. D3PM's standard 1000-step setting was much worse relative to its own optimum. This is also visible in the U-shaped cost–quality curve in Figure 1. We will add the grid totals and make this distinction explicit.
We have also changed the selection protocol. Sampler settings are now selected using 2,000 generated samples against a held-out validation split, with n=11,219 real images, and the selected setting is then evaluated once on the test split using 10,000 generated samples. We applied the same procedure to all 18 vocabulary-1024 cells. Under this protocol, DFM becomes worse on all three tokenizers; for example, LFQ-1024 changes from 1.77 to 2.26. The new protocol removes the best-of-test-grid limitation in the submitted paper.
On the single-seed point, we agree. We retrained the vocabulary-1024 block, {VQ, LFQ, FSQ} x {AR, MaskGIT, D3PM}, together with SEDD on LFQ, using seeds 42, 43, and 44. Every run was evaluated on the same GPU. The median standard deviation across cells is 0.047. D3PM and SEDD are relatively stable, with standard deviations of 0.02–0.04, while AR and MaskGIT vary more, with standard deviations of 0.05–0.21.
We will replace the broad statement that “LFQ wins 15 of 18” with the result supported by the seeded block. Six of the nine pairwise quantizer comparisons are larger than three times the pooled standard deviation. These include the comparisons that establish the interaction. LFQ is best under AR and D3PM, both with mean FID 0.39, whereas FSQ is best under MaskGIT at 1.15 and LFQ is worst at 1.92. The FSQ–LFQ difference under MaskGIT is 0.77, well above the measured seed variation.
Three comparisons are not resolved by the seeded results: VQ versus LFQ and VQ versus FSQ under MaskGIT, and LFQ versus FSQ under AR. We will not claim an ordering for these comparisons. The rest of the 18-cell grid remains single-seed, so the seed-supported claim will be limited to the vocabulary-1024 block.
We also computed standard FID-2048 from the same samples used for FID-192 on 12 cells spanning FID-192 values from 0.07 to 8.44. The Spearman correlation between the two metrics is 0.80. They agree on the broad structure of the results and identify AE+RF, tuned LFQ-D3PM, and the VAE references as the strongest cells. They disagree on some of the ordering among poor cells. For example, VQ-MaskGIT is worst under FID-2048 but lies closer to the middle under FID-192. None of our conclusions depends on the precise ordering within this group. A classifier two-sample test, which uses neither Inception features nor a Gaussian approximation, also agrees with FID-192 at Spearman 0.78.
This experiment showed that the statement in Appendix C that FID-2048 is degenerate at 64 x 64 is incorrect. At 10,000 samples, the real-versus-real FID-2048 floor is 2.31, with standard deviation 0.016 and no negative values across 20 resamples. We will remove that claim. FID-192 will instead be described as a lower-dimensional internal metric whose broad ranking agrees with standard FID-2048.
We also tested the proposed explanation for the PneumoniaMNIST reversal. We subsampled ChestMNIST to three training-set sizes and retrained AR with LFQ-1024 and VQ-1024:
| ChestMNIST training images | LFQ+AR | VQ+AR | Lower FID |
|---|---|---|---|
| 4,700 | 0.946 | 2.023 | LFQ |
| 20,000 | 0.366 | 1.770 | LFQ |
| 78,468 | 0.340 | 2.254 | LFQ |
LFQ remains better at all three sizes, including 4,700 examples, and the gap does not narrow at the smallest size. This rules out a simple training-set-size explanation for the PneumoniaMNIST result, where VQ+AR gives 1.00 and LFQ+AR gives 2.73. It does not identify the cause of the reversal, and we will not claim that it does. The practical conclusion is simply that reconstruction quality and dataset size are not reliable rules for selecting a tokenizer.
On novelty, we agree that natural-image work has already shown that reconstruction quality does not reliably predict generation quality. We will cite that work directly and will not present this observation alone as new.
The additional contribution is the matched analysis of quantizer, rate, generator, and sampler, together with the neighbour-conditional predictive-gain result. Reconstruction PSNR has Spearman correlation +0.01, and marginal entropy, which was the explanation proposed in the submission, does not separate the tokenizer families. Neighbour-conditional predictive gain does separate them in the current nine-tokenizer analysis. We will present this as an initial generator-free measure of modelability, with the small sample size stated clearly.
The reviewer asked for three to five seeded cells. We evaluated ten cells at three seeds.
We could not add the requested higher-resolution experiment during the discussion period. We do not have tokenized data at 128 or 224 pixels, and retokenizing and retraining at four times the token count was not feasible in the available window. We will limit the claims to low-resolution medical-style images. A matched non-medical replication and a higher-resolution study remain follow-up experiments.
The additional results support the quantizer–generator interaction within the seeded block, but they also require us to narrow several claims and correct the discussion of FID-2048.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Thank you for the careful reading and constructive comments. We used the discussion period to run additional experiments addressing the main points in the meta-review. Unless stated otherwise, the results below were obtained after submission.
Both concerns in the meta-review are fair. The observation that reconstruction quality does not predict generation quality is already established in natural-image work. We will cite that literature more directly and will not present this observation by itself as the novelty of the paper.
One new result from the discussion period is a generator-free analysis of the token fields. Reconstruction PSNR has Spearman correlation +0.01 with downstream generation quality. Marginal token entropy also does not separate the tokenizer families, with rank-AUC 0.50. This matters because marginal entropy was the explanation proposed in the submitted paper.
Neighbour-conditional predictive gain performs better in this analysis. It measures how much knowing the token immediately to the left or above reduces uncertainty about the current token. Using smoothing selected on a validation split, it separates the three VQ tokenizers from the six LFQ and FSQ tokenizers with rank-AUC 1.00. There are only nine tokenizers, so we will report this as a small-sample result rather than a general law about tokenizer modelability. It nevertheless provides an intrinsic measurement that was absent from the submitted paper.
The other contribution is the interaction measured within the matched factorial. LFQ is best under AR and D3PM, while FSQ is best under MaskGIT. Sampler selection can also change the apparent ordering of generators. We are not aware of prior work that measures all of these factors together in the same controlled design, although the individual observations are clearly related to prior natural-image results.
The submitted paper used one training run per cell. We have now retrained the vocabulary-1024 block using seeds 42, 43, and 44, with all runs evaluated on the same GPU. Six of the nine pairwise quantizer comparisons are larger than three times the pooled standard deviation, including the comparisons that establish the quantizer–generator interaction. Three comparisons remain within seed variation, and we will not claim an ordering for them. The seeded evidence covers this block; the wider 18-cell grid remains single-seed.
We also compared FID-192 with standard FID-2048 using the same samples from 12 representative cells. Their Spearman correlation is 0.80, and they agree on the broad separation between good and poor models. A classifier two-sample test agrees with FID-192 at Spearman 0.78 and does not use Inception features or a Gaussian approximation.
This comparison showed that the claim in Appendix C that FID-2048 is degenerate at 64 x 64 is wrong. At 10,000 samples, the real-versus-real FID-2048 floor is 2.31, with no negative values across 20 resamples. We will correct this and describe FID-192 as a lower-dimensional internal metric whose broad ranking agrees with standard FID-2048.
We will also remove the suggestion that the PneumoniaMNIST reversal is explained by its smaller training set. When ChestMNIST is subsampled to 4,700 examples, LFQ+AR still outperforms VQ+AR, with FID-192 of 0.946 versus 2.023. LFQ remains better at every tested ChestMNIST size. This rules out the simple size explanation but does not identify what causes the reversal on PneumoniaMNIST.
The medical framing will be narrowed as well. The experiments use low-resolution medical-style images and do not test subtle clinical variation at higher resolution. The current evidence does not support claims about medical image generation in general.
The current generators are unconditional, so a direct synth-then-classify experiment would not be well defined because the generated images do not have pathology labels. We added a classifier two-sample test as a label-free comparison, but we will not present it as evidence of clinical utility. A proper downstream study would require pathology-conditional generation and valid labels.
The revised paper will therefore make a narrower claim than the submitted version. It provides a controlled study of quantizer, rate, generator, and sampler in low-resolution medical-image generation, shows that these choices interact within the seeded block, and reports an initial generator-free statistic associated with the observed tokenizer differences. The practical recommendation remains to evaluate the tokenizer together with the generator and sampler rather than selecting it from reconstruction quality alone.
We hope the additional seed, metric, and modelability analyses address the two reasons given against acceptance in the meta-review.