Text-Guided Medical Image Segmentation via Residual Aggregation and Dense Alignment Representations
Jie Gui, Hang Tu, Yunfeng Dou, Wen Sha, Xiuquan Du, Shuo Li
NeurIPS 2026
TL;DR. RADAR combines BiomedCLIP and MedSAM2 with semantic-guided residual aggregation and structured dense alignment for accurate text-guided medical image segmentation using only 0.74M trainable parameters.
Abstract. Specifying segmentation targets with natural language provides flexible semantic conditioning for medical image segmentation. However, existing methods still struggle to reliably ground high-level textual semantics into accurate pixel-level spatial prompts, especially under low-contrast lesions, ambiguous boundaries, and visually similar anatomical contexts. In this paper, we propose RADAR (Residual Aggregation and Dense Alignment Representations), a parameter-efficient framework for text-guided medical image segmentation. RADAR explicitly decouples and synergizes the medical semantic anchoring capability of BiomedCLIP with the prompt-driven mask decoding ability of MedSAM2, while enabling low-cost task adaptation via LoRA. Specifically, Guided Residual Depth Aggregation adaptively aggregates cross-layer features under semantic guidance to alleviate delayed textual injection and deep semantic dilution. Structured Dense Representation Alignment leverages a frozen BiomedCLIP to construct crop-level target, boundary, and context anchors, improving the local discriminability of dense features and the reliability of automatic prompts. Multi-modal Prompt Generation further converts cross-modal semantic responses into composite text, point, and mask prompts for MedSAM2 decoding. Experiments on three public medical image segmentation datasets show that RADAR achieves competitive performance with only 0.74M trainable parameters, demonstrating its effectiveness in parameter-efficient adaptation, semantic grounding, and dense representation enhancement. The source code is available at https://github.com/JGuiidev/RADAR.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:48 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper proposes RADAR, a parameter-efficient text-guided medical segmentation framework that combines BiomedCLIP and MedSAM2 through residual feature aggregation, dense semantic alignment, and multimodal prompt generation. The reviewers agree that the framework is technically coherent, achieves competitive performance with only a small number of extra trainable parameters (0.74 M), and is supported by useful ablations across several backbone combinations [UvF1, YVDC, J8CX]. However, all three reviewers question the degree of novelty, particularly whether GRDA, SDRA, and MPG offer a sufficiently distinct contribution over existing feature-aggregation, dense-alignment, and VLM-SAM prompt-generation methods [UvF1, YVDC, J8CX]; the rebuttal should therefore clearly position each component against its closest predecessors and explain what is technically new beyond their combination. The main empirical concerns are the narrow evaluation on binary 2D tasks, the lack of analysis of noisy or ambiguous prompts, the absence of variance estimates, reliance on handcrafted thresholding and morphology in prompt generation, and omission of several directly relevant VLM-SAM baselines [UvF1, YVDC, J8CX]. The response should prioritize these issues and clarify the expected generalization beyond the evaluated settings.
Final justification
I would like to acknowledge that the reviewers and I read the responses offered by the authors. Based on reviewers' mostly positive responses and my own analysis of authors' rebuttals, most of the concerns raised in the reviews and the meta-review were convincingly addressed. Taking this into account, I am confident in recommending this paper for acceptance.
Read meta-review
Meta-review
The paper proposes RADAR, a parameter-efficient text-guided medical segmentation framework that combines BiomedCLIP and MedSAM2 through residual feature aggregation, dense semantic alignment, and multimodal prompt generation. The reviewers agree that the framework is technically coherent, achieves competitive performance with only a small number of extra trainable parameters (0.74 M), and is supported by useful ablations across several backbone combinations [UvF1, YVDC, J8CX]. However, all three reviewers question the degree of novelty, particularly whether GRDA, SDRA, and MPG offer a sufficiently distinct contribution over existing feature-aggregation, dense-alignment, and VLM-SAM prompt-generation methods [UvF1, YVDC, J8CX]; the rebuttal should therefore clearly position each component against its closest predecessors and explain what is technically new beyond their combination. The main empirical concerns are the narrow evaluation on binary 2D tasks, the lack of analysis of noisy or ambiguous prompts, the absence of variance estimates, reliance on handcrafted thresholding and morphology in prompt generation, and omission of several directly relevant VLM-SAM baselines [UvF1, YVDC, J8CX]. The response should prioritize these issues and clarify the expected generalization beyond the evaluated settings.
Final justification
I would like to acknowledge that the reviewers and I read the responses offered by the authors. Based on reviewers' mostly positive responses and my own analysis of authors' rebuttals, most of the concerns raised in the reviews and the meta-review were convincingly addressed. Taking this into account, I am confident in recommending this paper for acceptance.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 2/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 1/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper targets the practically important problem of grounding natural language into pixel-level segmentation in medical imaging. RADAR is technically coherent, carefully implemented, and its parameter efficiency result is genuinely noteworthy. The internal ablations are conducted with reasonable care across multiple configurations. However, the core contributions are incremental extensions of well-established mechanisms rather than conceptually new ideas. The experimental comparison has meaningful gaps in baseline coverage and dataset diversity, and the performance gains from the full system over simpler cascade alternatives are modest. Together these issues make it difficult to argue the work advances the field in proportion to the complexity introduced. The paper represents solid engineering work, but novelty and empirical validation fall short of the bar required for acceptance at this venue.
Strengths and weaknesses
Strengths:
The figures are generally well-produced and visually clean. Figure 3 in particular is well-organized, with the color-coded true positive, false negative, and false positive overlay scheme making cross-method qualitative comparison straightforward and interpretable at a glance.
Achieving competitive performance with only 0.74M trainable parameters while keeping both BiomedCLIP and MedSAM2 fully frozen is a practically meaningful result. Compared to V-L+S baselines like DIT (103.38M) and LGA (97.91M), the parameter gap is substantial and the efficiency argument holds up regardless of the novelty concerns.
Tables 2, 3, 4, and 6 provide a reasonably comprehensive internal analysis covering component contributions, backbone generalization, GRDA fusion variants, and LoRA injection ranges. The fact that GRDA and SDRA are tested across multiple backbone combinations in Table 3 is a good practice that strengthens the claim of general applicability of the two modules beyond the specific RADAR configuration.
Weaknesses:
The introduction identifies two bottlenecks (delayed semantic injection and lack of local discriminability) but the transition from problem motivation to proposed solution feels abrupt. The narrative jumps between VLMs, SAM, and contrastive learning without a clear unifying thread, making it harder to follow the logical progression toward RADAR's design choices.
While each proposed component is technically sound, the overall framework reads more as a careful integration of existing techniques than a conceptually novel contribution. GRDA, SDRA, and MPG each have clear and close predecessors in the literature, and the paper does not offer a principled theoretical account of why this particular combination generalizes beyond the empirical gains observed on three datasets.
Figure 1 occupies substantial page space yet largely restates content already covered in the introduction and later formalized in Figure 2. The three-panel layout (challenge, limitations, solution) could be condensed into a compact schematic, freeing space for more informative experimental content or architectural detail.
The captions throughout the paper, particularly for Figures 2 and 3, are minimal and largely descriptive of what is already visually apparent. A good caption should convey the key takeaway independently of the main text, for example explaining what the qualitative differences in Figure 3 demonstrate about each method's failure modes.
The motivation around delayed text-visual fusion as a core bottleneck has been substantially addressed in prior work, including [1] and [2] among others. The paper does not sufficiently situate GRDA with respect to these efforts or articulate what fundamentally distinguishes its semantic injection mechanism beyond the addition of a text-guided weighting term.
Several directly comparable VLM-SAM methods cited in the related work, including MedCLIP-SAMv2, TGSAM-2, and SegMoTE, are absent from Table 1 without justification, and stronger architectural baselines such as Swin-UNETR are not included. Furthermore, the ablation in Table 2 reveals that the simplest cascade baseline already captures most of the performance gain, with the full RADAR machinery yielding only incremental improvements that may not justify the added architectural complexity.
MPG relies entirely on handcrafted operations including quantile thresholding, morphological erosion, and dilation for point and mask prompt generation. The authors acknowledge this as a limitation but it also directly undermines the claim of a learned, generalizable framework, particularly for complex or low-contrast lesions where these heuristics are most likely to fail.
[1] Sultan, Rafi Ibn, et al. "Bipvl-seg: Bidirectional progressive vision-language fusion with global-local alignment for medical image segmentation." arXiv preprint arXiv:2503.23534 (2025).
[2] Cho, Yubin, Hyunwoo Yu, and Suk-Ju Kang. "Cross-aware early fusion with stage-divided vision and language transformer encoders for referring image segmentation." IEEE Transactions on Multimedia 26 (2023): 5823-5833.
Questions
MedCLIP-SAMv2, TGSAM-2, and SegMoTE are all directly comparable VLM-SAM cascades cited in your related work but absent from Table 1. Can the authors provide results for these methods under the same data splits and training protocol? If computational constraints prevented this, at minimum a discussion of how RADAR compares conceptually to these methods is needed.
Table 2 shows that the simplest BiomedCLIP-SAM2 cascade without GRDA or SDRA already achieves 90.02 Dice on Kvasir, while the full RADAR reaches 92.15. Can the authors clarify what the computational and architectural cost of the added components is relative to this 2-point gain? Specifically, does the added complexity of GRDA and SDRA translate to consistent improvements across all datasets and metrics, or are the gains dataset-dependent? A clearer efficiency-performance tradeoff analysis would strengthen the justification for the full system.
The evaluation is limited to two 2D chest infection datasets and one polyp dataset, which share relatively similar imaging characteristics. The conclusion mentions extensions to 3D and multi-class settings as future work. Can the authors provide even preliminary evidence, on a single 3D dataset or a modality outside chest and colonoscopy, that RADAR's design choices generalize? Without this, the scope of the empirical claims feels narrow relative to the generality implied by the framework's design.
Limitations
yes.
Final justification
The authors substantively addressed my experimental concerns during the rebuttal. They added the missing directly comparable VLM-SAM baselines under a matched protocol, reported multi-seed variance, provided a learnable prompt-generation comparison showing the handcrafted MPG is a defensible trade-off, and extended evaluation to a new modality via ISIC 2018 dermoscopy. They also corrected my misreading of the cascade result, showing the full modules contribute beyond the bare backbone. My main outstanding concern is the conceptual novelty, which the authors situate more clearly through per-module mechanistic distinctions but cannot fully resolve within a rebuttal, along with the presentation issues that are deferred to revision. Weighing the strengthened empirical validation against these points, I am raising my rating, while noting that novelty and presentation clarity remain the paper's soft spots and would benefit from the promised manuscript revisions.
Formatting concerns
No concerns.
3 comments
I thank the authors for the thorough rebuttal. The added VLM-SAM baselines, multi-seed variance estimates, learnable prompt-generation comparison, and dermoscopy experiment address my experimental concerns, and I appreciate the clarification on the 90.02 configuration. My remaining reservation is presentation: the proposed revisions sound reasonable, and I would want to see them reflected in the manuscript. I will update my score accordingly.
We thank the reviewer for the careful follow-up and for reconsidering our submission. We are pleased that the additional experiments and clarifications have addressed the reviewer’s main concerns.
We also attach great importance to the reviewer's suggestions regarding the presentation of the manuscript. In the revised version, we will systematically refine the organization and clarity of the paper: restructuring the introduction and related work sections, optimizing the figures, enriching the figure captions, standardizing table nomenclature, and clarifying conclusions that might otherwise be misinterpreted. We hope these revisions will more accurately and clearly convey the contributions and scope of applicability of our method.
We will ensure that these revisions are fully reflected in the manuscript. We again thank the reviewer for the time, careful consideration, and constructive feedback.
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper studies text-guided medical image segmentation, where segmentation targets are specified using natural language descriptions. This paper points out that existing vision-language and SAM-based methods still have difficulty translating high-level textual semantics into accurate spatial prompts for segmentation. To address this issue, they propose RADAR, a parameter-efficient framework that combines BiomedCLIP for semantic understanding and MedSAM2 for prompt-based mask decoding. The framework includes three main components: Guided Residual Depth Aggregation (GRDA) for improving semantic information propagation across layers, Structured Dense Representation Alignment (SDRA) for enhancing the discriminability of dense features using semantic anchors, and Multi-modal Prompt Generation (MPG) for generating text, point, and mask prompts from cross-modal responses. Experiments on three public medical image segmentation datasets show that the proposed method achieves competitive performance while introducing only a small number of trainable parameters.
Strengths and weaknesses
This paper studies text-guided medical image segmentation and proposes RADAR, a parameter-efficient framework that combines BiomedCLIP and MedSAM2. The method includes three main components: Guided Residual Depth Aggregation (GRDA), Structured Dense Representation Alignment (SDRA), and Multi-modal Prompt Generation (MPG). Experimental results on three public datasets show that the proposed method achieves competitive performance while maintaining a relatively small number of trainable parameters.
I think the paper addresses an interesting and practical problem. The overall framework is easy to follow, and the motivation of combining the semantic understanding ability of BiomedCLIP with the segmentation capability of MedSAM2 is reasonable. The experimental section is fairly comprehensive, including comparisons with existing methods, component ablations, and evaluations on different backbone combinations. In addition, the method achieves consistent improvements across multiple datasets while using only 0.74M trainable parameters, which demonstrates good parameter efficiency.
At the same time, I have several concerns. First, while the overall framework is well designed, the novelty of some components is not fully clear to me. GRDA appears related to existing feature aggregation strategies, and MPG seems to extend existing prompt-generation pipelines in VLM-SAM frameworks. Among the proposed components, SDRA appears to be the most distinctive contribution, but its novelty relative to existing dense representation alignment methods could be discussed more clearly. Second, the paper emphasizes delayed semantic injection as a major limitation of previous methods, but the improvements between some GRDA variants reported in Table 4 are relatively small, making it difficult to judge how critical this issue is in practice. Third, most results are reported as single values without variance estimates or statistical significance analysis, which makes it harder to assess the robustness of the reported improvements.
Questions
-
According to Table 2, the point prompt seems to contribute most of the improvement within MPG, while the additional mask prompt provides relatively limited gains. Could the authors further discuss the role of the mask prompt and when it is most beneficial?
-
If computationally feasible, it would be helpful to report performance variance over multiple runs or provide statistical significance analysis, especially when comparing with strong baselines where the performance differences are relatively small.
-
The experiments are conducted on three public datasets covering chest infection and polyp segmentation. Do the authors expect the proposed framework to generalize to other medical imaging modalities or segmentation tasks?
Limitations
The authors discuss the dependence on pretrained BiomedCLIP and MedSAM2, as well as the heuristic nature of the prompt generation process. However, the paper does not discuss the relatively limited diversity of the evaluation datasets, which may affect the assessment of generalization across broader medical imaging domains.
Final justification
The authors have satisfactorily addressed most of my concerns. Based on the rebuttal, I believe the paper is now suitable for acceptance.
Formatting concerns
No major issues were found regarding formatting, anonymity, or other submission requirements.
4 comments
Rebuttal
We thank the reviewer for the careful evaluation. We have clarified the method positioning and added five-run stability analysis and a dermoscopic fine-grained attribute experiment.
1. Novelty of GRDA, SDRA, and MPG
We agree that layer aggregation, crop-to-dense alignment, and VLM--SAM prompt generation have precedents. RADAR is not a simple combination of these mechanisms; it defines a continuous semantic-to-spatial path that converts medical text into reliable prompts executable by a segmentation foundation model.
RADAR decouples the task: BiomedCLIP provides text-conditioned semantic grounding, while MedSAM2 performs prompt-conditioned mask reconstruction. This exposes two consecutive bottlenecks. First, text is often introduced only after visual encoding and therefore cannot determine which historical visual representations should be retained during encoding. Second, even text-relevant dense features may still confuse the target body, ambiguous boundaries, and visually similar neighboring tissues. GRDA and SDRA address these two requirements, respectively, while MPG converts the enhanced response into prompts accepted by MedSAM2.
GRDA versus conventional aggregation and early fusion. Conventional depth aggregation generally uses modality-agnostic queries or image-dependent scores to weight historical layers, whereas early-fusion methods repeatedly inject language features through multi-stage cross-attention. GRDA instead uses text tokens to route historical visual layers separately at each spatial position, asking which depth at each location is useful for the text-specified target. This spatially resolved text-conditioned routing distinguishes GRDA from generic aggregation and heavy fusion.
SDRA versus generic dense alignment. Existing methods commonly use random crops, grids, boxes, or a single target region. SDRA instead constructs target, boundary, and context regions around insufficient target activation, inaccurate boundaries, and false responses in adjacent similar tissues. It further introduces boundary-negative rejection, which prevents the boundary representation from becoming as target-like as the target representation. Thus, SDRA moves beyond independent teacher matching and explicitly models the relative semantic structure among target, boundary, and context.
Positioning of MPG. MPG bridges the interface mismatch between BiomedCLIP and MedSAM2. From the same cross-modal response, it generates a projected Text Prompt, positive points from reliable target cores, negative points from nearby confusing backgrounds, and a continuous Mask Prompt. These provide target semantics, sparse localization, and coarse spatial extent. We position MPG as an interpretable interface rather than a general prompt-learning theory.
Accordingly, GRDA, SDRA, and MPG are not an arbitrary empirical combination. They arise from consecutive framework requirements: cross-layer semantic retention, local target--boundary--context discrimination, and executable prompt generation. We will revise the Introduction and Related Work and strengthen comparisons with modality-agnostic aggregation, early fusion, BiPVL-Seg, CLIPSelf, and related prompt pipelines.
2. Small differences among GRDA variants in Table 4
Table 4 compares internal fusion forms after GRDA is enabled, not GRDA versus no GRDA. It selects the most balanced implementation and should not imply that Base+Guidance is significantly better than every variant. We will revise the claim to: Base+Guidance provides the most balanced overall performance across datasets and metrics. GRDA's contribution is better assessed by removal studies:
| Comparison | Mos ΔDice | Mos ΔmIoU | Kvasir ΔDice | Kvasir ΔmIoU |
|---|---|---|---|---|
| Full MPG → Full MPG + GRDA | +1.31 | +1.73 | +0.99 | +1.32 |
| w/o GRDA → RADAR | +0.84 | +1.13 | ||
| w/o SDRA → RADAR | +0.52 | +0.40 | ||
| Full MPG → RADAR | +4.00 | +4.76 | +1.79 | +2.36 |
The gain is larger on low-contrast, diffuse MosMedData+ lesions, while Kvasir has a stronger salient-target baseline. Cross-backbone removal studies also improve Dice, mIoU, HD95, and ASSD. We will clearly separate the questions of whether GRDA helps and which internal fusion is most balanced.
3. Role of the Mask Prompt
We agree that the Point Prompt supplies the main gain and the Mask Prompt provides a smaller, consistent complement.
| Dataset | Prompt Setting | Dice | mIoU | ΔDice | ΔmIoU |
|---|---|---|---|---|---|
| MosMedData+ | Text Prompt | 69.86 | 55.68 | - | - |
| MosMedData+ | Text + Point Prompts | +1.28 | +1.79 | ||
| MosMedData+ | Text + Point + Mask Prompts | 71.47 | 57.67 | ||
| Kvasir | Text Prompt | 88.73 | 82.17 | - | - |
| Kvasir | Text + Point Prompts | +1.20 | +1.45 | ||
| Kvasir | Text + Point + Mask Prompts | 90.36 | 84.29 |
Reliable positive/negative points directly indicate what to retain and exclude, and MedSAM2 can expand them into masks. The Mask Prompt instead supplies coarse continuous extent and is more useful for large, irregular, disconnected, or diffuse targets that few points cannot cover. It consistently improves both datasets at low extra cost. We will clarify the division of labor among semantic Text Prompts, sparse Point Prompts, and continuous Mask Prompts without implying equal marginal contributions.
4. Multi-run variance and stability
We used seeds 42, 1, 2, 3, and 4 for five independent runs of RADAR and representative baselines, changing only the random seed.
| Method | QaTa Dice ↑ | QaTa mIoU ↑ | QaTa HD95 ↓ | QaTa ASSD ↓ | Mos Dice ↑ | Mos mIoU ↑ | Mos HD95 ↓ | Mos ASSD ↓ | Kvasir Dice ↑ | Kvasir mIoU ↑ | Kvasir HD95 ↓ | Kvasir ASSD ↓ |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TransUNet | 77.63±0.48 | 67.57±0.58 | 30.45±0.73 | 8.24±0.27 | 62.27±0.95 | 48.09±1.13 | 27.11±5.47 | 6.70±1.35 | 86.02±0.34 | 78.57±0.62 | 20.96±2.97 | 6.13±0.64 |
| LAVT | 83.87±0.38 | 75.33±0.42 | 3.91±0.21 | 66.18±1.59 | 52.41±1.59 | 18.88±2.05 | 4.66±0.55 | 89.30±0.77 | 83.31±0.88 | 14.40±2.02 | 4.44±0.67 | |
| RecLMIS | 83.54±0.51 | 74.80±0.68 | 15.55±0.74 | 4.29±0.21 | 17.86±0.67 | 86.69±3.02 | 79.19±3.83 | 21.73±2.93 | 5.71±0.90 | |||
| MMI-UNet | 15.17±1.56 | 4.14±0.39 | 70.93±1.01 | 57.17±1.01 | 4.33±0.61 | 16.57±2.80 | ||||||
| DIT | 79.76±0.55 | 70.18±0.64 | 29.90±1.56 | 8.06±0.45 | 71.76±0.78 | 58.53±0.84 | 18.96±3.35 | 4.32±0.70 | 89.39±1.18 | 83.44±1.40 | 16.77±1.31 | 5.05±0.59 |
| RADAR | 84.45±0.19 | 75.80±0.25 | 13.55±0.86 | 75.45±0.21 | 62.26±0.39 | 11.42±1.24 | 3.00±0.20 | 92.27±0.20 | 86.83±0.34 | 3.82±0.40 |
RADAR leads the overlap metrics on all datasets, with QaTa ASSD comparable to LAVT and Kvasir HD95 second to LAVT. Across the tested splits and settings, its Dice and mIoU show low cross-run variation.
5. Other modalities and tasks
We added ISIC 2018 Task 2 with five dermoscopic attributes. The targets are small, sparse, disconnected, irregular, and visually similar. We use only The dermoscopic image contains {attribute_name}. without GT-derived spatial information.
| Method | Trainable Parameters ↓ | FLOPs ↓ | Dice (%) ↑ | mIoU (%) ↑ | HD95 ↓ | ASSD ↓ |
|---|---|---|---|---|---|---|
| LViT | M | 27.08 G | 40.44±1.82 | 28.85±1.47 | 41.25±0.73 | 15.71±0.73 |
| MMI-UNet | 56.18 M | 11.04 G | 43.99±1.29 | 31.69±1.17 | 37.70±0.65 | 13.46±0.40 |
| LAVT | 189.73 M | 49.69 G | 39.55±3.18 | 29.10±2.17 | 38.17±1.74 | 13.86±1.25 |
| RecLMIS | 69.44 M | G | ||||
| DIT | 103.38 M | 92.82 G | 37.83±1.70 | 27.27±1.52 | 41.16±0.08 | 16.37±0.12 |
| RADAR | 0.74 M | 46.66 G | 48.61±0.71 | 35.50±0.55 | 33.75±0.13 | 12.00±0.26 |
RADAR leads all four segmentation metrics, improving over RecLMIS by 1.87 Dice/1.46 mIoU and reducing HD95/ASSD by 3.94/0.81. This extends modality, target morphology, and text-conditioned category space, but does not replace native 3D, multi-organ, or simultaneous multiclass validation.
We again thank the reviewer. The suggestions helped us clarify novelty, Table 4, the Mask Prompt, stability, and cross-task generalization.
I thank the authors for the detailed and substantive rebuttal. The response has addressed my main empirical concerns. In particular, the clarification that Table 4 compares different internal GRDA fusion variants, rather than GRDA versus no GRDA, resolves my concern regarding the relatively small differences among those variants.
The explanation and incremental ablation of the Mask Prompt also clarify its role as a smaller but consistent complement to the Point Prompt, particularly for spatially extended, irregular, or disconnected targets. In addition, the five-run results substantially strengthen the robustness evaluation, and the ISIC 2018 experiment provides useful evidence of generalization to a different imaging modality and more challenging target morphologies.
My remaining reservation concerns conceptual novelty. Although the rebuttal more clearly distinguishes GRDA, SDRA, and MPG from their closest predecessors, the overall contribution still builds on mechanisms with related prior foundations. Nevertheless, the strengthened empirical validation, parameter efficiency, and clearer mechanistic positioning make the paper more convincing overall.
Response (1/2)
We thank the reviewer for the further assessment. We are pleased that the newly added multi-run evaluation, Mask Prompt analysis, and dermoscopic attribute segmentation experiment have addressed the main empirical concerns. Regarding the reviewer’s remaining reservation about conceptual novelty, we would like to provide the following clarification.
Due to the character limit, we divide this response into two consecutive parts.
1. The core contribution of RADAR is a framework-level methodology
Existing text-guided segmentation methods generally follow two paradigms. One relies on multi-stage, parameter-heavy vision-language interactions that repeatedly fuse language into the visual encoding process. The other directly converts the final response of a VLM into prompts for SAM. The former incurs substantial training costs, whereas the latter, despite its simplicity, remains constrained by late-stage semantic injection and the limited spatial quality of the original dense VLM responses.
After establishing RADAR, we identified two consecutive bottlenecks within this framework. First, although text can participate in final image-text matching, it cannot determine which historical visual evidence should be retained during encoding. Second, even when text-relevant responses are obtained, the dense features still struggle to distinguish the target body, ambiguous boundaries, and neighboring visually similar tissues. GRDA and SDRA were derived specifically to address these two framework-internal bottlenecks, while MPG arises from the interface mismatch between the outputs of BiomedCLIP and the inputs expected by MedSAM2.
2. GRDA
Existing early-fusion methods mainly use mechanisms such as cross-attention to repeatedly write textual information into the current visual representation, thereby modifying the cross-modal feature content at the current layer. Existing depth-aggregation methods, by contrast, generally assign weights to representations from different depths using visual features themselves or modality-agnostic queries, with the goal of obtaining a more comprehensive generic visual representation.
GRDA addresses a fundamentally different question: how textual semantics should influence the propagation of visual information across network depth. It does not directly write textual content into the visual features, nor does it merely perform generic multi-layer fusion. For the target specified by the current text, GRDA determines, at each spatial location, how much visual evidence from different historical layers should be retained and propagated to subsequent encoding stages.
GRDA therefore does not simply ask which layers are globally more important. Instead, it asks which depth of visual evidence should be inherited at a particular location for the target described by the text. Its central mechanism is that text, spatial position, and network depth jointly determine how historical visual information is retained. This differs fundamentally from both conventional aggregation and early fusion, and it is not a capability that emerges automatically from simply connecting BiomedCLIP with MedSAM2.
3. SDRA
Existing dense-alignment methods commonly use random crops, regular grids, or local views to encourage dense features to approach their corresponding teacher representations. Their primary objective is to improve consistency between local and global semantics.
SDRA instead starts from the characteristic error patterns of medical image segmentation. It maps insufficient target activation, ambiguous boundary prediction, and false responses in neighboring similar tissues to three structured regions: target, boundary, and context. It then further constrains the relative semantic relationships among these regions: the target representation should reliably express the target semantics, whereas the boundary representation should not become as target-like as the target itself.
SDRA therefore addresses what structural relationship the target, boundary, and context should form with respect to the same target semantics. It converts characteristic medical segmentation errors into relational constraints within the dense representation space, thereby suppressing boundary confusion and contextual false activation at the representation level. This is a substantive adaptation and transformation of general crop-to-dense alignment for the specific requirements of medical segmentation, rather than a direct transfer of an existing method.
Response (2/2, continued)
4. MPG
After GRDA and SDRA, the model obtains text-relevant and locally discriminative dense responses. However, these representations still cannot be directly executed by MedSAM2. MPG ensures that the representations enhanced by GRDA and SDRA are fully transferred to MedSAM2, rather than being reduced again to a single coarse spatial signal at the interface between the two models.
We do not position MPG as a new general theory of prompt learning. Instead, we regard it as the interpretable interface required to complete the semantic-to-spatial transformation pathway.
5. Experimental evidence
Full MPG already contains BiomedCLIP, MedSAM2, and the complete set of Text, Point, and Mask Prompts. It can therefore be regarded as a strong VLM-SAM combination baseline, but it does not include GRDA, Dense Modification, or SDRA. On top of this baseline, the complete RADAR improves Dice/mIoU by 4.00/4.76 percentage points on MosMedData+ and by 1.79/2.36 percentage points on Kvasir. These results show that the main gains do not arise merely from combining the foundation models or using multiple prompt types, but from the targeted modification of cross-layer information flow and dense semantic structure within the framework.
Moreover, GRDA and SDRA consistently improve performance across CLIP-SAM2, BiomedCLIP-SAM2, and CLIP-MedSAM2. This indicates that they address common bottlenecks in decoupled VLM-SAM frameworks rather than providing an incidental adaptation to one specific backbone combination. The five-run evaluation and cross-modality experiment further support the stability and applicability of these mechanisms.
In summary, the novelty of RADAR lies in three closely connected aspects:
- It introduces a decoupled and parameter-efficient framework for text-guided medical image segmentation, establishing a complete text-to-pixel pathway while keeping both foundation models frozen.
- Starting from the internal bottlenecks exposed by this framework, it introduces text-controlled cross-layer retention of visual information and relational dense representation learning over target, boundary, and context.
- It converts these representation-level improvements into composite prompts executable by MedSAM2 through a unified semantic-to-spatial interface, achieving stable gains with only 0.74M trainable parameters.
We will reorganize the Introduction, Related Work, and Methodology sections accordingly, so that the framework-level contribution and the technical novelty of the proposed mechanisms are presented more accurately and clearly.
We hope that the above clarification, together with the additional empirical evidence, addresses the reviewer’s remaining concern regarding conceptual novelty. We would be sincerely grateful if the reviewer could reconsider the overall rating in light of the full rebuttal. We fully respect the reviewer’s final judgment and again thank the reviewer for the time and constructive feedback.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes RADAR, a parameter-efficient framework for text-guided medical image segmentation built upon BiomedCLIP and MedSAM2. Instead of directly injecting language features into the segmentation decoder, the proposed framework decouples semantic understanding and mask prediction through multi-prompt generation and semantic-guided dense representation alignment. The method introduces three key components, namely Multi-Prompt Generation (MPG), Global Residual Dense Aggregation (GRDA), and Structured Dense Representation Alignment (SDRA), to improve cross-modal semantic interaction while requiring only 0.74M trainable parameters. Extensive experiments on three public datasets demonstrate consistent improvements over recent vision-language segmentation approaches and strong parameter efficiency. Overall, the paper presents a practical framework for efficiently adapting foundation models to text-guided medical image segmentation.
Strengths and weaknesses
Strengths
- The paper proposes a clean decoupling between semantic grounding (BiomedCLIP) and prompt-based segmentation (MedSAM2), resulting in a modular and interpretable framework.
- The proposed method requires only 0.74M trainable parameters, making it considerably more efficient than many existing vision-language segmentation approaches while maintaining competitive performance.
- The paper includes extensive comparisons, component ablations, backbone analyses, and qualitative evaluations across three public datasets, providing convincing empirical evidence for the proposed modules.
- The proposed GRDA and SDRA modules consistently improve multiple VLM-SAM backbone combinations, suggesting that the proposed components are not tightly coupled to a specific foundation model.
Weaknesses
- Most components are built upon existing foundation models (BiomedCLIP, MedSAM2, LoRA) together with several feature aggregation modules. While the engineering is solid, the overall conceptual novelty appears incremental relative to recent text-guided SAM adaptation literature.
- The Multi-Prompt Generation module depends on thresholding, connected-component analysis, and morphological operations, which introduces manually designed heuristics rather than fully learnable prompt generation.
- The experiments are restricted to binary segmentation tasks (infection and polyp segmentation). It remains unclear whether the proposed framework generalizes to multi-class segmentation, 3D medical imaging, or more challenging anatomical structures.
- Although the framework is text-guided, the paper does not sufficiently investigate sensitivity to prompt quality, incomplete descriptions, or noisy clinical text, which are common in real-world medical applications.
Questions
- The proposed MPG relies on several heuristic operations (thresholding, connected-component analysis, erosion, dilation). Could these steps be replaced with a fully learnable prompt generation mechanism?
- The experiments mainly focus on binary segmentation tasks. How does the proposed framework perform on multi-class segmentation or anatomically complex organs?
- Since BiomedCLIP provides global semantic representations, how sensitive is the framework to inaccurate, ambiguous, or incomplete text prompts?
- The paper emphasizes parameter efficiency. Could the authors also provide inference speed, GPU memory usage, and computational cost comparisons with competing methods?
- The proposed framework is based on MedSAM2. To what extent would the proposed modules generalize to alternative segmentation foundation models?
- Can the proposed semantic alignment mechanism naturally extend to volumetric (3D) medical image segmentation?
Limitations
yes
Final justification
The rebuttal has addressed most of my concerns, and the revisions are consistent with the feedback from the other reviewers. Therefore, I lean toward a borderline accept.
Formatting concerns
N/A
1 comment
Rebuttal
We thank the reviewer. We added experiments and clarified the method positioning.
1. Novelty of RADAR, GRDA, SDRA, and MPG
Historical-layer aggregation, crop-to-dense alignment, and LoRA have prior foundations. RADAR instead defines a continuous semantic-to-spatial path from medical text to executable pixel-level prompts.
RADAR decouples BiomedCLIP semantic anchoring from MedSAM2 mask decoding. Two bottlenecks remain: text cannot select historical representations during encoding, and text-relevant responses may still confuse target, boundary, and context. GRDA/SDRA address them, while MPG produces executable prompts.
GRDA differs from generic aggregation and early-fusion methods: it uses text as a routing condition and computes historical-layer weights per spatial location, rather than applying modality-agnostic weights or repeatedly injecting language through cross-attention.
SDRA constructs target, boundary, and context regions rather than generic crops. Boundary-negative rejection prevents boundary features from becoming as target-like as the target, enforcing relative regional discrimination rather than only teacher matching.
MPG is an interpretable interface rather than a new general prompt-learning theory. It converts one cross-modal response into a Text Prompt, target-core positive points, neighboring hard negatives, and a continuous Mask Prompt. Thus, the three components arise naturally from consecutive requirements: cross-layer semantic retention, local spatial discrimination, and executable prompt generation. We will revise the Introduction/Related Work and compare them directly with modality-agnostic aggregation, early-fusion methods, BiPVL-Seg, CLIPSelf, and related prompt pipelines.
2. Can MPG be replaced by a learnable prompt generator?
Yes. We changed only the spatial prompt conversion while keeping BiomedCLIP, MedSAM2, GRDA, SDRA, losses, and training settings fixed. RADAR-SimMask directly uses the normalized similarity map; RADAR-Extrema samples global maximum/minimum responses; RADAR-LMPG concatenates final BiomedCLIP spatial features with the similarity map and predicts a Mask Prompt and positive/negative heatmaps using a three-layer convolutional head. Spatial softmax produces probability maps and differentiable soft-argmax produces point coordinates.
| Method | Trainable Parameters | Mos Dice ↑ | Mos mIoU ↑ | Mos HD95 ↓ | Mos ASSD ↓ | Kvasir Dice ↑ | Kvasir mIoU ↑ | Kvasir HD95 ↓ | Kvasir ASSD ↓ |
|---|---|---|---|---|---|---|---|---|---|
| RADAR-SimMask | 0.74 M | 74.81 | 61.68 | 14.05 | 3.33 | 91.00 | 84.98 | 19.49 | 4.72 |
| RADAR-Extrema | 0.74 M | 13.71 | 3.57 | 91.55 | 85.75 | 16.84 | 4.31 | ||
| RADAR-LMPG | 0.91 M | 75.10 | 61.97 | 92.24 | 86.74 | ||||
| RADAR | 0.74 M | 75.47 | 62.43 | 13.16 | 3.26 | 14.79 | 3.91 |
Direct maps and extrema perform worse, showing that cross-modal responses still contain isolated false activations, unstable edges, and spatial noise. RADAR-LMPG is feasible and marginally improves Kvasir Dice, but is worse on Kvasir boundary metrics and all MosMedData+ metrics, while increasing trainable parameters from 0.74 M to 0.91 M (+22.97%). The original MPG offers a more balanced trade-off in the current setting; learnable prompt generation remains a promising extension.
3. Additional modality and complex targets
We added ISIC 2018 Task 2 dermoscopic attribute segmentation, covering pigment network, negative network, streaks, milia-like cysts, and globules/dots. These targets are often small, sparse, disconnected, irregular, and visually similar. Since image-specific text is unavailable, we use only The dermoscopic image contains {attribute_name}. without GT-derived location, number, size, shape, or boundary information.
| Method | Trainable Parameters ↓ | FLOPs ↓ | Dice (%) ↑ | mIoU (%) ↑ | HD95 ↓ | ASSD ↓ |
|---|---|---|---|---|---|---|
| LViT | M | 27.08 G | 40.44±1.82 | 28.85±1.47 | 41.25±0.73 | 15.71±0.73 |
| MMI-UNet | 56.18 M | 11.04 G | 43.99±1.29 | 31.69±1.17 | 37.70±0.65 | 13.46±0.40 |
| LAVT | 189.73 M | 49.69 G | 39.55±3.18 | 29.10±2.17 | 38.17±1.74 | 13.86±1.25 |
| RecLMIS | 69.44 M | G | ||||
| DIT | 103.38 M | 92.82 G | 37.83±1.70 | 27.27±1.52 | 41.16±0.08 | 16.37±0.12 |
| RADAR | 0.74 M | 46.66 G | 48.61±0.71 | 35.50±0.55 | 33.75±0.13 | 12.00±0.26 |
RADAR is best on all four segmentation metrics, improving over RecLMIS by 1.87 Dice/1.46 mIoU and reducing HD95/ASSD by 3.94/0.81. This extends evaluation to dermoscopy and five text-conditioned fine-grained attributes. Native 3D, multi-organ, and more complex anatomical settings remain limitations.
4. Sensitivity to inaccurate, ambiguous, incomplete, or noisy text
We fixed one checkpoint and all images and changed only test-time text. Incomplete prompts remove disambiguating location, number, or extent attributes and therefore represent under-specified, potentially ambiguous text.
| Text Type | QaTa Dice ↑ | QaTa mIoU ↑ | QaTa HD95 ↓ | QaTa ASSD ↓ | Mos Dice ↑ | Mos mIoU ↑ | Mos HD95 ↓ | Mos ASSD ↓ |
|---|---|---|---|---|---|---|---|---|
| Original | 84.12 | 75.32 | 14.27 | 4.09 | 75.47 | 62.43 | 13.16 | 3.26 |
| Empty | 76.90 | 66.92 | 33.90 | 10.13 | 67.80 | 54.40 | 20.49 | 5.23 |
| Incomplete | 82.01 | 71.95 | 20.32 | 5.67 | 73.72 | 60.53 | 13.77 | 3.60 |
| Mild Noise | ||||||||
| Synonym | 83.26 | 74.32 | 19.95 | 5.39 | 74.56 | 61.41 | 13.79 | 3.33 |
| Wrong | 70.33 | 58.38 | 46.25 | 13.98 | 70.63 | 57.00 | 26.34 | 6.86 |
Mild noise and synonyms cause only small Dice drops, while incomplete text causes moderate degradation. Empty text decreases Dice by 7.22/7.67 points and substantially worsens boundaries; wrong text causes stronger regional or boundary errors. RADAR tolerates semantic-preserving changes but still depends on correct image-text correspondence.
5. Practical efficiency
All methods were tested under the same hardware, precision, and protocol; inference uses batch size 1 and includes the complete image-text forward pass.
| Method | Trainable Parameters (M) ↓ | FLOPs (G) ↓ | Memory (GiB) ↓ | Speed (imgs/s) ↑ | Checkpoint (MB) ↓ |
|---|---|---|---|---|---|
| TransUNet | 105.28 | 49.36 | 56.78 | 401.89 | |
| LViT | 27.08 | 20.80 | 26.46 | ||
| MMI-UNet | 56.18 | 11.04 | 11.87 | 19.47 | 632.69 |
| LAVT | 189.73 | 49.69 | 8.59 | 27.67 | 2416.72 |
| RecLMIS | 69.44 | 20.39 | 842.25 | ||
| DIT | 103.38 | 92.82 | 25.84 | 44.29 | 1658.97 |
| RADAR | 0.74 | 46.66 | 10.48 | 30.46 | 8.69 |
RADAR reduces task-specific trainable parameters by 98.15%-99.61% and the task checkpoint to 8.69 MB. We do not claim the lowest value on every compute metric: its FLOPs and speed are moderate. The precise claim is strong task-adaptation and storage efficiency with moderate forward cost. The SDRA teacher is training-only and removed at inference.
6. Other segmentation foundation models
Relative to removing both GRDA and SDRA, the full modules improve every overlap and boundary metric across SAM2/MedSAM2 and CLIP/BiomedCLIP combinations:
| Backbone Combination | Dataset | ΔDice ↑ | ΔmIoU ↑ | ΔHD95 ↓ | ΔASSD ↓ |
|---|---|---|---|---|---|
| RADAR-CLIP-SAM2 | MosMedData+ | +2.72 | +3.38 | -4.35 | -1.32 |
| RADAR-CLIP-SAM2 | Kvasir | -4.98 | |||
| RADAR-BiomedCLIP-SAM2 | MosMedData+ | +1.45 | +1.50 | -2.13 | -0.60 |
| RADAR-BiomedCLIP-SAM2 | Kvasir | +1.11 | +2.04 | -3.64 | -1.06 |
| RADAR-CLIP-MedSAM2 | MosMedData+ | +1.34 | +1.44 | -1.20 | -0.59 |
| RADAR-CLIP-MedSAM2 | Kvasir | +1.45 | +2.65 | -1.51 |
SDRA acts on VLM dense features; MPG mainly relies on SAM-family Point and Mask Prompt interfaces; GRDA requires multi-layer encoder features and therefore needs candidate-layer, resolution, and channel adaptation. The evidence supports transfer from SAM2 to MedSAM2, but not adaptation-free compatibility with every foundation model.
7. Volumetric 3D extension
In 3D, SDRA can extend target, boundary, and context regions to a target volume, surface shell, and neighboring context volume, with 3D teacher anchors and mask-weighted ROI pooling. GRDA aggregates network depth, not slice depth; spatial tokens can be extended to volumetric tokens with corresponding adaptation of layers, projections, and computation. A full implementation still requires suitable volumetric VLM/segmentation backbones and must address anisotropy, cross-slice text, empty volumes, memory, and 3D teacher crops. Thus, the method has a clear extension path, while native 3D validation remains future work.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Rebuttal
We thank the reviewer for the detailed evaluation. We added direct VLM-SAM baselines, learnable prompt generation, efficiency, multi-seed evaluation, and dermoscopic attribute segmentation.
1. Novelty and integration concern
Layer aggregation, crop-to-dense alignment, VLM-SAM cascades, and LoRA have precedents. RADAR instead defines a semantic-to-spatial pathway with a clear functional progression. BiomedCLIP anchors semantics and MedSAM2 decodes masks, leaving two bottlenecks: historical-feature selection and target-boundary-context discrimination.
GRDA uses text-conditioned, spatially resolved depth routing rather than modality-agnostic weights or repeated early-fusion cross-attention. SDRA uses target-boundary-context regions and boundary-negative rejection rather than generic crop matching. MPG is an interpretable SAM-compatible prompt interface. They therefore follow consecutive needs--semantic retention, local discrimination, and prompt generation. We will revise the Introduction/Related Work and compare them directly with modality-agnostic aggregation, early-fusion methods, BiPVL-Seg, CLIPSelf, and related prompt pipelines.
2. Missing direct baselines
We added MedCLIP-SAMv2, TGSAM-2, and SegMoTE using the same splits, image-text samples, preprocessing, and evaluation code. All methods use seeds 42, 1, 2, 3, and 4; results are five-run mean±standard deviation.
RADAR leads these baselines on all metrics. MedCLIP-SAMv2 uses a response--pseudo-label--nnUNet pipeline, so localization errors propagate on diffuse MosMedData+ lesions. TGSAM-2 emphasizes tracking memory; SegMoTE emphasizes expert tokens, token-level MoE, and progressive prompt tokenization.
Swin-UNETR is designed for native 3D CT/MRI volumes, whereas our protocol uses native 2D images or independent 2D slices with image-level text. Pseudo-volume stacking or a 2D rewrite would change its task definition, and it has no text interface. We therefore retain the protocol-matched Swin-UNet baseline and will explain this explicitly.
3. The 90.02 result and performance-complexity trade-off
The cited 90.02 Kvasir Dice is the Table 3 Full configuration containing GRDA and SDRA, not a simple cascade. The actual w/o both result is 88.91. We will rename it RADAR-BiomedCLIP-SAM2.
For the final BiomedCLIP-MedSAM2 backbone, Full MPG already includes Text, Point, and Mask Prompts but excludes GRDA, Dense Modification, and SDRA:
Thus, even after a strong composite-prompt cascade, the representation path provides non-trivial further gains, especially on low-contrast, boundary-ambiguous MosMedData+. The gain is smaller on visually salient Kvasir targets. Improvements are consistent across backbones, although their magnitude is dataset/model dependent:
4. Practical cost
RADAR adds no large encoder/decoder. GRDA performs lightweight depth scoring/aggregation; Dense Modification reuses the final ViT Value features; the SDRA teacher and losses are training-only.
RADAR reduces task-specific trainable parameters by 98.15%-99.61% and the task checkpoint to 8.69 MB. Its FLOPs and speed are moderate rather than minimal, so we will claim task-adaptation/storage efficiency with moderate end-to-end computation.
5. Handcrafted MPG and learnable alternatives
We kept all other components/settings fixed and compared direct similarity-map prompts, global extrema points, and a learnable three-layer prompt head. RADAR-LMPG predicts a Mask Prompt and positive/negative heatmaps; spatial softmax and differentiable soft-argmax produce point coordinates.
Direct maps/extrema are less reliable because raw responses contain false activations and uncertain edges. RADAR-LMPG is viable, but increases trainable parameters from 0.74 M to 0.91 M (+22.97%) and is less balanced across datasets and boundary metrics.
6. Dataset diversity
We added ISIC 2018 Task 2 with five fine-grained dermoscopic attributes. These targets are small, sparse, disconnected, irregular, and visually similar. We use only
The dermoscopic image contains {attribute_name}.without GT-derived spatial information.RADAR leads all four segmentation metrics, improving over RecLMIS by 1.87 Dice/1.46 mIoU and reducing HD95/ASSD by 3.94/0.81. This extends modality and target morphology; native 3D, multi-organ, and multiclass validation remain limitations.
7. Presentation revisions
We will: (1) rewrite the Introduction as task gap → complementary foundations → two bottlenecks → decoupled framework → GRDA-SDRA-MPG progression; (2) simplify Figure 1; (3) separate inference and training-only paths in Figure 2 and clarify sparse/dense prompts; (4) expand Figure 3 captions to explain modality, difficulty, TP/FN/FP colors, and failure modes; and (5) rename BiomedCLIP-SAM2 Full as RADAR-BiomedCLIP-SAM2 and use Trainable Parameters consistently.