Selective Answering for Medical VQA via Parallel Independent Claim Verification
Donghee Han, Jiwon Jeong, Mun Yong Yi
NeurIPS 2026
TL;DR. PICV improves selective medical VQA by independently verifying typed visual claims and using rule-based aggregation to reduce answerability bias and produce transparent abstention reasons.
Abstract. Medical visual question answering is a safety-critical decision problem in which abstaining on inputs the image cannot support matters as much as answer accuracy. Existing inference-time agentic methods address hallucination by adding a verification step, but they collapse the final decision at a single language-model judge that integrates all evidence in one prompt and is systematically biased toward declaring inputs answerable. We propose PICV (Parallel Independent Claim Verification), which reformulates selective medical VQA as independent claim verification with transparent aggregation: the question is decomposed into a small set of typed visual claims, each is verified by an isolated prompt with no access to the other verdicts, and the verdicts are combined by a deterministic rule rather than another model, yielding an answer/abstain decision together with a typed unanswerability reason. We evaluate PICV efficiently on an automated answerability benchmark we construct over two public radiology datasets via three reproducible corruption procedures, requiring neither heavy VLM judging nor human annotation at evaluation time. Across four VLM backbones, PICV consistently outperforms strong prompting and agentic baselines; ablations attribute the gains specifically to per-claim isolation and rule-based aggregation rather than to agentic decomposition alone.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:47 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper addresses an important problem in medical visual question answering: selective answering, where models should abstain when the available image evidence is insufficient to support a reliable answer. It proposes Parallel Independent Claim Verification (PICV), which decomposes questions into independent visual claims, verifies each claim separately, and combines a deterministic rule-based decision process. The paper also introduces an automatically constructed answerability benchmark based on reproducible corruption procedures over two public radiology VQA datasets. The evaluation across multiple VLM backbones demonstrates consistent improvements in answerability prediction. However, several important questions remain:
- Evaluation beyond answerability prediction. Reviewers noted that the current evaluation primarily measures answerability decisions rather than the correctness of the generated medical answers themselves. Since PICV ultimately produces answers whenever it decides an input is answerable, please clarify whether the proposed framework also maintains or improves answer correctness on answerable cases, and discuss how selective answering interacts with downstream VQA accuracy.
- Generalizability of the proposed benchmark and evaluation protocol. Reviewers raised concerns that the benchmark is constructed using corruption types that closely align with PICV’s verifier taxonomy, potentially favoring the proposed method. Please clarify the intended scope of the benchmark, discuss this potential source of evaluation bias, and explain how the proposed framework is expected to generalize to naturally occurring unanswerable clinical scenarios beyond the current synthetic corruption setting.
- Scope of empirical validation. The current evaluation is conducted on relatively small subsets of two radiology VQA benchmarks. Please clarify the robustness of the reported improvements, discuss the limitations imposed by the current benchmark size and domain coverage, and explain how the proposed approach is expected to scale to broader medical VQA settings.
- Evidence supporting the claimed architectural advantage. Reviewers requested additional clarification regarding whether the reported improvements arise specifically from deterministic aggregation, rather than from the claim decomposition itself or other design choices. Please clarify the contribution of the individual components of PICV and discuss the extent to which deterministic aggregation is responsible for the observed performance gains.
- Presentation of practical trade-offs. Since the paper emphasizes both improved safety and inference efficiency, reviewers suggested presenting these trade-offs more explicitly. Please clarify the computational cost relative to competing agentic approaches and discuss the practical implications of the proposed framework for deployment.
Whether these issues can be satisfactorily addressed will significantly influence my final assessment.
Final justification
I have read the authors’ response in full, including the additional analyses and the post-rebuttal reviewer discussion. My initial meta-review leaned toward rejection because the original submission did not adequately establish final-answer correctness, benchmark neutrality, the specific benefit of deterministic aggregation, statistical robustness, or the practical cost of the method. The rebuttal provides substantial new evidence on each of these points and appropriately narrows the paper’s claims. On balance, this changes my recommendation to acceptance.
The engaged reviewers reached a similar conclusion. Two reviewers raised their ratings from Borderline Reject to Borderline Accept after examining the new analyses. One explicitly concluded that all major concerns had been addressed, while the other found that the evidence regarding retained-answer accuracy, benchmark-method alignment, and deterministic aggregation materially improved the paper. The remaining reviewer did not provide the requested final rating or justification after rebuttal and did not document a reassessment under the corrected Use-inspired contribution type. Following the Program Chairs’ guidance, I therefore place less weight on that unchanged score, while still considering the substantive concerns raised in the review.
Overall, the paper identifies a concrete and safety-relevant failure mode in single-judge medical VQA verification, proposes a transparent inference-time alternative, and provides evidence across four VLM backbones that independently verified claims and deterministic aggregation improve the safety-coverage frontier. The additional rebuttal analyses resolve the main concerns underlying my initial recommendation, while the remaining limitations principally constrain the scope of the claims rather than invalidate the contribution. I therefore recommend acceptance as a poster.
Finally, the reference “3d-RAD: A comprehensive 3d radiology med-VQA dataset with multi-temporal analysis and diverse diagnostic tasks” was flagged because the publication year is incorrect. The authors must correct this reference in the final version.
Read meta-review
Meta-review
This paper addresses an important problem in medical visual question answering: selective answering, where models should abstain when the available image evidence is insufficient to support a reliable answer. It proposes Parallel Independent Claim Verification (PICV), which decomposes questions into independent visual claims, verifies each claim separately, and combines a deterministic rule-based decision process. The paper also introduces an automatically constructed answerability benchmark based on reproducible corruption procedures over two public radiology VQA datasets. The evaluation across multiple VLM backbones demonstrates consistent improvements in answerability prediction. However, several important questions remain:
- Evaluation beyond answerability prediction. Reviewers noted that the current evaluation primarily measures answerability decisions rather than the correctness of the generated medical answers themselves. Since PICV ultimately produces answers whenever it decides an input is answerable, please clarify whether the proposed framework also maintains or improves answer correctness on answerable cases, and discuss how selective answering interacts with downstream VQA accuracy.
- Generalizability of the proposed benchmark and evaluation protocol. Reviewers raised concerns that the benchmark is constructed using corruption types that closely align with PICV’s verifier taxonomy, potentially favoring the proposed method. Please clarify the intended scope of the benchmark, discuss this potential source of evaluation bias, and explain how the proposed framework is expected to generalize to naturally occurring unanswerable clinical scenarios beyond the current synthetic corruption setting.
- Scope of empirical validation. The current evaluation is conducted on relatively small subsets of two radiology VQA benchmarks. Please clarify the robustness of the reported improvements, discuss the limitations imposed by the current benchmark size and domain coverage, and explain how the proposed approach is expected to scale to broader medical VQA settings.
- Evidence supporting the claimed architectural advantage. Reviewers requested additional clarification regarding whether the reported improvements arise specifically from deterministic aggregation, rather than from the claim decomposition itself or other design choices. Please clarify the contribution of the individual components of PICV and discuss the extent to which deterministic aggregation is responsible for the observed performance gains.
- Presentation of practical trade-offs. Since the paper emphasizes both improved safety and inference efficiency, reviewers suggested presenting these trade-offs more explicitly. Please clarify the computational cost relative to competing agentic approaches and discuss the practical implications of the proposed framework for deployment.
Whether these issues can be satisfactorily addressed will significantly influence my final assessment.
Final justification
I have read the authors’ response in full, including the additional analyses and the post-rebuttal reviewer discussion. My initial meta-review leaned toward rejection because the original submission did not adequately establish final-answer correctness, benchmark neutrality, the specific benefit of deterministic aggregation, statistical robustness, or the practical cost of the method. The rebuttal provides substantial new evidence on each of these points and appropriately narrows the paper’s claims. On balance, this changes my recommendation to acceptance.
The engaged reviewers reached a similar conclusion. Two reviewers raised their ratings from Borderline Reject to Borderline Accept after examining the new analyses. One explicitly concluded that all major concerns had been addressed, while the other found that the evidence regarding retained-answer accuracy, benchmark-method alignment, and deterministic aggregation materially improved the paper. The remaining reviewer did not provide the requested final rating or justification after rebuttal and did not document a reassessment under the corrected Use-inspired contribution type. Following the Program Chairs’ guidance, I therefore place less weight on that unchanged score, while still considering the substantive concerns raised in the review.
Overall, the paper identifies a concrete and safety-relevant failure mode in single-judge medical VQA verification, proposes a transparent inference-time alternative, and provides evidence across four VLM backbones that independently verified claims and deterministic aggregation improve the safety-coverage frontier. The additional rebuttal analyses resolve the main concerns underlying my initial recommendation, while the remaining limitations principally constrain the scope of the claims rather than invalidate the contribution. I therefore recommend acceptance as a poster.
Finally, the reference “3d-RAD: A comprehensive 3d radiology med-VQA dataset with multi-temporal analysis and diverse diagnostic tasks” was flagged because the publication year is incorrect. The authors must correct this reference in the final version.
- Rating
- 3/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper studies selective answering for medical VQA, where a model must answer when the image supports the question and abstain when it does not. The authors argue that existing inference-time agentic verifiers underperform because they ultimately collapse all evidence into a single VLM judge that is biased toward declaring inputs answerable, overwriting strong negative signals from individual visual probes. They propose PICV (Parallel Independent Claim Verification), which decomposes a question into typed atomic visual claims, verifies each in isolation (no access to the question, the other verdicts, or any draft answer), and combines the verdicts with a deterministic programmatic rule that emits an answer/abstain decision together with a typed abstention reason. To score abstention without a VLM judge or human labels, the authors construct an answerability benchmark by deterministically corrupting answerable SLAKE/VQA-RAD instances along three axes (image mismatch, choice removal, question corruption). Across four VLM backbones, PICV attains the highest answerability-F1 in 7 of 8 cells, and ablations attribute the gains to per-claim isolation and rule-based aggregation rather than to agentic decomposition alone.
Strengths and weaknesses
Strengths
- Important, under-served problem (Significance). Abstention in medical VQA is safety-critical yet ignored by standard benchmarks that contain only answerable inputs. The paper targets exactly this gap.
- Sharp diagnostic contribution (Quality/Originality). The "single-judge supported bias" — agentic verifiers produce per-probe negative evidence but collapse the final call into one biased VLM judge — is a genuine, useful observation. The statistic that this judge emits REFUTED zero times across 200+ missed unanswerable cases is crisp evidence.
- Clean, well-motivated design (Quality). Replacing the judge with per-claim isolation plus a deterministic aggregation rule is a sensible architectural commitment. The typed abstention reasons are practically meaningful because they route to different downstream clinical actions.
- Practical and reproducible (Quality). The method is no-fine-tuning and black-box-compatible, the benchmark construction is deterministic, and code is released. The ablations are honest and correctly localize the gain to per-claim isolation rather than decomposition itself.
- Strong clarity. The paper is well-organized and Figures 1–2 communicate the corruption protocol and the pipeline cleanly.
Weakness
- Limited conceptual novelty (Originality/Significance). Decompose-then-verify, parallel-vs-iterative verification, deterministic aggregation, and typed selective prediction are recombinations of existing inference-time patterns. The work reads as a careful engineering instantiation for one domain; the only fresh element is the supported-bias diagnosis, which is somewhat expected once stated.
- Pareto claim without cost in the main result (Quality). Table 1 reports only answerability-F1, yet the headline advantage on frontier backbones is explicitly "comparable accuracy at half the cost." Omitting the cost axis from the figure that makes the argument is not a defensible Pareto claim — a cost–quality scatter or an avg-calls/equal-budget column is needed.
- Self-constructed benchmark co-designed with the method (Quality/fairness). The three corruption axes map almost 1:1 onto PICV's own typed reasons, while baselines do not share this taxonomy. This raises a construct-validity concern that the benchmark is not neutral with respect to the method being evaluated.
- "Exact" labels are leaky (Quality). The authors admit SLAKE within-modality swaps share broad regions (abdomen/thorax), so the very low SLAKE image_mismatch true-abstain rates conflate label noise with model failure. A small clinician audit of ~50 "unanswerable" labels would settle this cheaply.
- Overstated statistical strength. Each cell has only 100 samples (~17 per corruption type), so the large per-corruption deltas in Tables 2–3 (e.g. pp) rest on tiny subsamples with no confidence intervals. The sign/Wilcoxon tests also treat 8 correlated cells as independent, making the -values optimistic.
- Concentrated, narrow gains (Significance). Tables 2–3 show the advantage is driven overwhelmingly by choice_missing (per-option MCQ verification), while image_mismatch is weak and question_corruption is SLAKE-only. An open-ended-only / excluding-choice_missing breakdown is needed to support the "consistent across scenarios" framing.
- Compressed metric (Quality). Because each cell is balanced 50/50, a trivial "always answer" policy already scores (recall , precision ). Several PICV results (–) sit only marginally above this floor, so the absolute numbers overstate how much is actually being gained.
- "No fine-tuning" understates the manual effort (Clarity). P2's ability to catch image_mismatch is bounded by a hand-built 60-entry entity-to-region table, not by the model. The paper frames PICV as "no fine-tuning," but this hides a real component of dataset-specific knowledge engineering that performance depends on.
Questions
- Cost in the main table. Please add an avg-calls column (or AnsF1-vs-calls scatter) to Table 1, since the Pareto claim is central yet not directly shown — my score rises if the cost–quality position is visible per cell.
- Benchmark neutrality. Your corruption axes map ~1:1 onto PICV's own typed reasons that baselines don't use, so please show PICV still wins on a corruption not aligned to its taxonomy — this is my main concern and a convincing answer would meaningfully raise my score.
- Label validity. A ~50-case clinician audit of SLAKE image_mismatch "unanswerable" labels (which can share a broad region) would show how much the low TAR is label noise vs. model failure — score drops if many are actually answerable.
- Where the gain comes from. Please report AnsF1 split by question type (or excluding choice_missing) to separate general selective answering from per-option MCQ verification — score rises if the advantage survives outside choice_missing.
Limitations
None
Formatting concerns
None
1 comment
- Rating
- 4/6
- Confidence
- 5/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This study targets selective answering in medical VQA, where models abstain when the image evidence is insufficient to support the question. The authors propose PICV, which decomposes a question into atomic visual claims, including entity presence, body region, and answer choice validity. Each claim is then verified using an isolated prompt, and the results are combined through a rule-based decision process. The system outputs either an answer or an abstention, along with a supporting rationale.
The evaluation uses a benchmark constructed by deterministically corrupting instances from SLAKE and VQA-RAD (100 instances each) along three axes: image mismatch, question corruption, and choice removal. Across four VLM backbones (Gemini, GPT-5.4-mini, MedGemma-4B, and Qwen2.5-VL-7B), PICV achieves the highest AnsF1 in 7 out of 8 settings, with gains of +0.6 to +9.6 percentage points over the strongest baseline.
The contribution is use-inspired, targeting clinical safety in radiology VQA.
Strengths and weaknesses
Strengths
- Well-identified failure mode with empirical evidence. The paper documents a concrete, quantifiable failure: the single-judge variant produces zero REFUTED verdicts for choice or region claims across 200+ missed unanswerable cases. This observation makes the study motivation direct and clearly linked to clinical meaning.
- Cross-backbone consistency. PICV is tested on four meaningfully different backbones: two frontier APIs and two on-premise models including a medical-domain-specialized VLM. The consistent improvement direction (7/8 cells) with statistical confirmation (sign test p=0.035, Wilcoxon p=0.016) strengthens the generalizability claim. The finding that MedGemma-4B exhibits the same systematic failure to abstain as general-purpose VLMs is an independently valuable observation.
Weakness
- Benchmark-method alignment inflates apparent gains. The benchmark tests exactly the three failure types that PICV is built to catch: wrong body region, missing entity, and invalid answer choices. Each corruption type has a matching PICV verifier designed to detect it, while the baselines have no such specialized detectors. This makes the comparison inherently favorable to PICV. The method may not perform as well on real-world unanswerable cases that don't fit these three categories, such as poor image quality or ambiguous clinical questions. The authors acknowledge the benchmark is synthetic but don't flag this structural alignment.
- No answer accuracy evaluation. AnsF1 measures only the binary answer/abstain decision. The paper never reports whether the answers produced by A4 (when d=ANSWER) are actually correct.
- Small benchmark size limits statistical precision. Each dataset has only 100 instances (50 answerable + 50 unanswerable). On SLAKE, which uses three corruption axes, each axis has 17 unanswerable instances. Per-corruption TAR values computed from 17 samples have substantial sampling uncertainty (~±10–15 pp for proportions). The cross-cell sign test has very low power at n=8. No bootstrap confidence intervals are reported at the per-cell level.
Questions
- The central thesis is that deterministic aggregation outperforms LLM-based aggregation. Can you run an ablation using the same A0–A2 decomposition and verification but replacing A3 with a lightweight LLM judge that receives all verdicts? This would directly isolate the aggregation mechanism from the decomposition design.
- Can you report accuracy of A4’s answers on the answerable subset where d=ANSWER? A system that correctly decides to answer but produces wrong answers is not useful for clinical deployment.
- Given that image_mismatch detection is essentially non-functional on SLAKE, would the authors report PICV results with image_mismatch instances excluded from the SLAKE benchmark to show performance on the corruption types where PICV is actually operative?
Limitations
The authors provide a thorough limitations discussion. Three remaining gaps:
- The structural alignment between the benchmark’s corruption axes and PICV’s verifier types is not explicitly acknowledged as a limitation, even though it represents the most significant threat to generalizability.
- The absence of an evaluation of answer accuracy is not mentioned.
- There are missing ablation studies to test whether deterministic aggregation outperforms LLM-based aggregation, and whether question-blind grounding effectively prevents entity inflation.
Final justification
The rebuttal addresses all three major concerns with new experiments: a taxonomy-disjoint degradation condition, answer accuracy analysis, and the deterministic vs. LLM aggregator ablation. The appropriately narrowed claims and honest acknowledgment of limitations justify revising the score from 3 to 4.
Formatting concerns
No formatting concerns.
1 comment
Rebuttal to Reviewer of7B
We thank the reviewer for identifying three central concerns: benchmark–method alignment, missing answer-accuracy evaluation, and limited statistical precision. We added direct controls for each and revise the primary evaluation from raw AnsF1 to coverage at equal harm and harmful answers at equal coverage.
W1. Benchmark–Method Alignment
“Each corruption type has a matching PICV verifier designed to detect it, while the baselines have no such specialized detectors.”
We agree that the original benchmark is structurally aligned with PICV’s typed verifiers. We therefore added a taxonomy-disjoint visual_degradation condition that weakens visual evidence without changing the image identity, question, or answer choices. No PICV verifier or rule is explicitly specialized to this condition.
| Method | AnsF1 | Coverage at equal harm | AURC |
|---|---|---|---|
| Direct | 0.667 | 0.787 | 0.800 |
| ReAct | 0.693 | 0.762 | 0.717 |
| PICV | 0.710 | 0.838 | 0.677 |
PICV has the best observed result among the three evaluated methods, providing initial evidence beyond its original taxonomy. We will report this as limited synthetic evidence rather than proof of robustness to naturally occurring ambiguity.
We also removed all choice_missing cases. Raw AnsF1 gains become substantially smaller, confirming that multiple-choice verification contributes to the original margin. However, at an equal harmful-answer budget, PICV still answers more questions than 6 of 7 baselines, and the same pattern holds on open-ended questions.
Our revised claim is therefore:
Benchmark alignment contributes to the raw AnsF1 gain, but PICV’s safety–coverage advantage is not limited to corruption types explicitly matched by its verifiers.
The final version will additionally include naturally occurring ambiguous or insufficient-evidence cases.
W2 & Q2. Final-Answer Accuracy
“The paper never reports whether the answers produced by A4, when (d=\text{ANSWER}), are actually correct.”
We now evaluate A4’s answers on the same 366 answerable cases retained by PICV. Conditional SoftAcc is 0.593 for PICV and 0.598 for Direct, indicating that the accuracy of retained answers is nearly unchanged.
When abstentions are counted as incorrect over all answerable cases, accuracy decreases from 0.613 to 0.543. We will therefore report conditional accuracy, overall answerable-case accuracy, and coverage together rather than implying that abstention is cost-free.
PICV reduces harmful answers—wrong answers on answerable cases or unsupported answers on unanswerable cases—from 69.4 to 41.4 per 100 queries. At equal coverage, it produces fewer harmful answers than Direct, Two-stage, and ReAct-Med.
Our supported conclusion is that PICV improves the safety–coverage trade-off, not unconditional VQA accuracy. We will describe SoftAcc as benchmark answer equivalence rather than clinician-verified medical correctness.
W3. Benchmark Size and Statistical Precision
“Each dataset has only 100 instances… No bootstrap confidence intervals are reported at the per-cell level.”
We agree that the original statistical framing was too broad. Per-cell analysis supports a more consistent improvement over Direct than over the strongest alternative baseline, so we will treat cross-baseline rankings as descriptive and remove universal robustness claims.
Because the same source questions are evaluated across multiple backbones, the final version will use source-question-clustered uncertainty estimates, report exact corruption-specific denominators, and expand the per-cell evaluation. The visual_degradation analysis will similarly be clustered by source pair.
Q1. Deterministic Rule versus an LLM Aggregator
“Can you replace A3 with a lightweight LLM judge that receives the same verdicts?”
We replaced only the final aggregation rule with the same backbone that generated each verification trace, while keeping A0–A2 and all claim-level evidence fixed.
| Aggregator | Answer rate | AnsF1 | Harmful/100 |
|---|---|---|---|
| Deterministic rule | 0.730 | 0.752 | 47.50 |
| Same-backbone judge, native | 0.580 | 0.602 | 37.00 |
| Judge at rule coverage | 0.730 | 0.659 | 49.75 |
| Judge at rule harm budget | 0.708 | 0.650 | 47.50 |
At equal coverage, the deterministic rule achieves higher AnsF1 and 2.25 fewer harmful answers per 100. At the same harmful-answer budget, it provides additional coverage.
This supports the narrower claim that deterministic aggregation preserves isolated negative evidence more reliably than the evaluated prompted same-backbone judge. We do not claim superiority over every possible learned aggregator.
Q3. SLAKE without image_mismatch
“Would the authors report PICV results with
image_mismatchinstances excluded from SLAKE?”
Yes. Removing all SLAKE image_mismatch cases leaves 86 samples per backbone. PICV ranks first in prior-balanced AnsF1 across all four SLAKE backbone settings, with scores from 0.729 to 0.870 and margins of 0.062–0.136 over the strongest baseline.
This shows that PICV’s SLAKE performance is not dependent on the weak image_mismatch axis.
We also found that 25 of 166 SLAKE image_mismatch cases retain a donor-image annotation answering the same normalized question, indicating that some swaps do not remove the required evidence. A blinded clinician audit will be reported in the final version. Until it is completed, we treat the automatic analysis only as evidence consistent with label noise.
Revised Contribution
We will narrow the contribution to:
- identifying and quantifying supported bias in single-judge selective VQA;
- showing that isolated claim verification improves the safety–coverage trade-off; and
- demonstrating that deterministic aggregation preserves claim-level negative evidence better than a prompted same-backbone aggregator under matched operating points.
We will explicitly scope these findings to two English radiology VQA datasets and avoid claims of comprehensive clinical robustness.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper studies selective answering for medical visual question answering, where a model should answer only when the image provides sufficient evidence and abstain otherwise. The authors propose Parallel Independent Claim Verification (PICV), an inference-time framework that decomposes a medical VQA query into typed visual claims, verifies each claim independently using isolated prompts, and then applies a deterministic aggregation rule to decide whether to answer or abstain with a typed reason. The paper also constructs an answerability benchmark from public radiology VQA datasets using deterministic corruption procedures, including image mismatch, question corruption, and choice removal. Experiments on SLAKE and VQA-RAD with four vision-language model backbones show that PICV generally improves answerability F1 over direct answering, prompting-based abstention, and agentic verification baselines, while providing more transparent abstention reasons and lower inference cost than some multi-step agentic methods
Strengths and weaknesses
Strengths:
- The paper addresses an important safety problem in medical VQA. The Introduction clearly explains that many Medical VQA systems assume every input is answerable, which may force models to produce confident answers even when the image lacks necessary evidence.
- The motivation is well grounded in a concrete failure mode. The paper argues that a confident wrong answer may be more harmful than refusal in clinical settings. This is a reasonable and clinically meaningful motivation.
- The deterministic aggregation step is a strength. Unlike single-judge agentic methods, PICV does not ask one VLM to combine all evidence into a final decision. Algorithm 1 specifies how verifier outputs are combined by rule.
Weaknesses:
- The biggest quality concern is that the benchmark evaluates answerability, not full VQA correctness. The primary metric AnsF1 is defined over the answer/abstain decision. It does not directly evaluate whether the generated answer is medically correct when the model chooses to answer.
- The sample size is relatively small. Appendix A states that each backbone-dataset cell draws 50 answerable seeds and pairs them with 50 corrupted variants. This gives a clean benchmark, but the per-cell sample size may be too limited for broad claims about robust medical VQA behavior.
- The evaluation is restricted to two public English radiology datasets, SLAKE and VQA-RAD. Appendix E also acknowledges that pathology, fundus, non-radiology modalities, and broader population coverage are out of scope. This limits the significance for general medical VQA.
Questions
- Can the authors evaluate final answer correctness on answerable cases, not only answerability F1? Since A4 generates an answer when PICV decides to answer, the paper should report whether those answers are medically correct.
- How well does PICV perform on naturally occurring unanswerable or ambiguous clinical questions, rather than synthetically corrupted inputs?
- How robust is the 60-entry entity-region table when moving beyond SLAKE and VQA-RAD? Does performance degrade when questions involve more fine-grained anatomy or pathology-specific entities?
- Can the authors compare against a fine-tuned abstention classifier or selective prediction baseline? This would clarify whether PICV’s advantage comes from its structure or from avoiding training.
- Can the authors provide more analysis of the weak image_mismatch TAR on SLAKE? Table 2 shows very low image_mismatch TAR in several SLAKE settings, which seems important for visual grounding.
Limitations
Yes. The authors have addressed the limitations appropriately and have substantially narrowed the claims. A few limitations nevertheless remain. The evaluation is still relatively small and largely based on synthetic unanswerable cases from two English radiology VQA datasets, so robustness to naturally occurring clinical ambiguity and broader medical domains remains unverified. In addition, the manually constructed entity–region map has limited coverage, and some statistical analyses and clinician-adjudicated validation are deferred to the final version.
Final justification
I appreciate the authors’ detailed rebuttal. The additional analyses address several of my main concerns, particularly regarding retained-answer accuracy, benchmark–method alignment, and deterministic aggregation. The revised framing around the safety–coverage trade-off is better supported and appropriately scoped. While some limitations remain, the new evidence improves my overall assessment. I have therefore revised my score from 3 to 4.
Formatting concerns
No major formatting concerns.
1 comment
Rebuttal to Reviewer KNee
We thank the reviewer for emphasizing that answerability prediction alone is insufficient to establish the usefulness of selective medical VQA. We added analyses of retained-answer correctness, safety–coverage trade-offs, benchmark validity, entity-map coverage, and learned aggregation baselines.
W1 & Q1. Final-Answer Correctness
“The primary metric AnsF1 is defined over the answer/abstain decision. It does not directly evaluate whether the generated answer is medically correct when the model chooses to answer.”
“Can the authors evaluate final answer correctness on answerable cases, not only answerability F1?”
We now evaluate answers on the same 366 answerable cases for which PICV selects ANSWER. Conditional SoftAcc is 0.593 for PICV and 0.598 for Direct, showing that the accuracy of retained answers is nearly unchanged.
When abstentions are counted as errors over all answerable cases, accuracy decreases from 0.613 to 0.543. We therefore distinguish retained-answer accuracy, coverage, and overall answerable-case accuracy rather than implying that abstention is cost-free.
PICV reduces harmful answers—wrong answers on answerable cases or unsupported answers on unanswerable cases—from 69.4 to 41.4 per 100 queries. At the same harmful-answer budget, it answers more questions than all seven baselines; at the same coverage, it produces fewer harmful answers than Direct, Two-stage, and ReAct-Med.
Our revised claim is that PICV improves the safety–coverage trade-off, not that it improves unconditional VQA accuracy. We will describe SoftAcc as benchmark answer equivalence rather than clinician-verified medical correctness.
W2. Limited Sample Size
“The per-cell sample size may be too limited for broad claims about robust medical VQA behavior.”
We agree. The current per-cell results support consistent improvement over Direct, but do not establish universal superiority over every baseline.
We will narrow the paper’s claims to the controlled benchmark setting, report exact denominators, and expand the per-cell evaluation in the final version. Because the same source questions are evaluated across multiple backbones, we will also report source-question-clustered uncertainty estimates rather than treating all outputs as independent.
W3. Restricted Datasets and Modalities
“The evaluation is restricted to two public English radiology datasets, SLAKE and VQA-RAD.”
We agree that the current results do not establish general medical VQA robustness. We will explicitly scope the title, abstract, and conclusion to selective answering on two English radiology VQA datasets.
Pathology, fundus imaging, non-radiology modalities, non-English questions, and clinical deployment will be identified as untested settings. We will also add a broader-domain evaluation in the final version.
Q2. Naturally Occurring Unanswerability
“How well does PICV perform on naturally occurring unanswerable or ambiguous clinical questions, rather than synthetically corrupted inputs?”
We added a taxonomy-disjoint visual_degradation condition that weakens visual evidence without changing the image identity, question, or choices. No PICV verifier is explicitly designed for this corruption.
| Method | AnsF1 | Coverage at equal harm | AURC |
|---|---|---|---|
| Direct | 0.667 | 0.787 | 0.800 |
| ReAct | 0.693 | 0.762 | 0.717 |
| PICV | 0.710 | 0.838 | 0.677 |
PICV has the best observed result among the three evaluated methods. However, this remains a synthetic evidence-degradation setting, not naturally occurring clinical ambiguity.
We will add naturally occurring ambiguous or insufficient-evidence cases in the final version and report them separately from corruption-based evaluation.
Q3. Entity–Region Map Robustness
“How robust is the 60-entry entity-region table when moving beyond SLAKE and VQA-RAD?”
The implementation contains 62 manually engineered entries. Across the current traces, the region verifier maps 49% of the claims for which it is invoked; unmatched entities return UNCLEAR.
This fail-open behavior avoids map-only false REFUTED decisions, but reduces the ability to detect mismatches involving unseen or fine-grained entities. We will therefore describe the map as task-specific knowledge engineering, not domain-general adaptation, and make no robustness claim for pathology-specific or fine-grained anatomy without additional evaluation.
Q4. Fine-Tuned Selective-Prediction Baseline
“Can the authors compare against a fine-tuned abstention classifier or selective prediction baseline?”
We trained a supervised aggregation head using the same claim-level verdicts as the deterministic rule.
| Aggregator | Answer rate | AnsF1 | Harmful/100 |
|---|---|---|---|
| Trained, leave-one-cell-out | 0.635 | 0.819 | 36.9 |
| Trained, leave-one-dataset-out | 0.535 | 0.742 | 32.0 |
| Deterministic rule | 0.685 | 0.772 | 41.4 |
The trained head performs better within the same datasets. Under cross-dataset evaluation, it operates at substantially lower coverage, so the native results do not establish that either approach is superior.
We will compare the trained head and deterministic rule at matched coverage and matched harmful-answer budgets in the final version. We will also add a leakage-controlled end-to-end selective-prediction baseline.
Separately, replacing the deterministic rule with the same backbone that generated the verification evidence reduces performance at matched operating points. At equal coverage, the rule achieves higher AnsF1 and 2.25 fewer harmful answers per 100.
This supports the narrower claim that deterministic aggregation preserves isolated negative evidence more reliably than a prompted same-backbone judge.
Q5. Weak SLAKE image_mismatch Performance
“Can the authors provide more analysis of the weak image_mismatch TAR on SLAKE?”
We found that 25 of 166 SLAKE image_mismatch cases retain a donor-image annotation that answers the same normalized question. These cases therefore do not reliably remove the required evidence and provide an automatic lower bound on benchmark noise.
After excluding them, PICV’s safety–coverage advantage remains and its harmful-answer rate decreases from 41.4 to 33.7 per 100.
We have prepared a blinded 50-case clinician-audit set. The completed adjudication will be reported in the final version in either direction. Until then, we treat the automatic analysis as evidence consistent with label noise, not a clinician-verified noise estimate.
Revision Summary
The final version will jointly report answerability, retained-answer correctness, overall answerable-case accuracy, coverage, harmful answers, false refusals, and inference cost. We will also explicitly acknowledge the limited sample size, two-dataset radiology scope, synthetic ambiguity, incomplete entity-map coverage, and absence of clinician-adjudicated correctness.
Comments on the paper
1 comment
Summary of rebuttal
We thank the reviewer again for the constructive feedback. Based on the reviews and the Meta Reviewer’s guidance, we conducted additional analyses addressing the shared concerns regarding final-answer correctness, benchmark–method alignment, statistical precision, architectural attribution, and inference cost.
In particular, we now show that:
- PICV maintains nearly unchanged conditional answer accuracy relative to Direct answering (0.593 vs. 0.598), while substantially reducing harmful answers from 69.4 to 41.4 per 100 queries.
- Its safety–coverage advantage remains under a taxonomy-disjoint visual-degradation condition, after removing choice_missing, and on open-ended questions.
- Holding claim-level evidence fixed, deterministic aggregation outperforms a prompted same-backbone judge at matched coverage and harm budgets.
- The SLAKE image-mismatch analysis identifies benchmark noise, while excluding the affected cases further strengthens the safety–coverage result.
- We explicitly report the computational and engineering trade-offs, including 4.65 calls per sample and the limited coverage of the manually constructed entity–region map.
We have consequently narrowed the paper’s central claim: PICV does not improve unconditional VQA accuracy or establish general clinical robustness; rather, within the evaluated English radiology VQA setting, it improves the safety–coverage frontier by preserving independently verified negative evidence.
We would be grateful if the reviewer could let us know whether these additional results and the revised claim address the main concerns raised in the review, or whether any critical issue remains unresolved.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Rebuttal to Reviewer Ci6h
We thank the reviewer for identifying concrete analyses that could change the assessment. We completed the requested cost analysis, taxonomy-disjoint evaluation,
choice_missing-excluded analysis, and label-quality investigation. We also revise the primary evaluation from raw AnsF1 to coverage at matched harm and harm at matched coverage.W1. Limited Conceptual Novelty
We agree that decomposition, verification, and deterministic rules are not individually new primitives. We will narrow the contribution to:
We will not claim that PICV introduces each component independently or outperforms every learned selective predictor.
W2 & Q1. Cost–Quality Trade-off
PICV uses an average of 4.65 calls per sample, compared with 8.86 for MediQ-Scale.
PICV is therefore more call-efficient than the iterative MediQ-Scale baseline, but more expensive than single- or short-pass methods. We will add calls per sample to the main table and include a cost–quality scatter. We will describe this as call efficiency, not a general monetary or latency advantage.
W3 & Q2. Benchmark Neutrality
We added a taxonomy-disjoint
visual_degradationcondition that weakens visual evidence without changing the image identity, question, or choices. No PICV verifier or aggregation rule is explicitly specialized to this condition.PICV achieves the best observed result among the three evaluated methods. This provides taxonomy-independent evidence, although the current sample remains limited. We will report source-pair-clustered uncertainty and add naturally occurring insufficient-evidence cases in the final version.
W4 & Q3. SLAKE Label Validity
We found that 25 of 166 SLAKE
image_mismatchcases retain a donor-image annotation answering the same normalized question. These cases do not reliably remove the required evidence and constitute an automatic lower bound on invalid unanswerable labels.After excluding them, PICV’s safety–coverage advantage remains, and its harmful-answer rate decreases from 41.4 to 33.7 per 100 queries.
A blinded 50-case clinician-audit set is prepared. The completed adjudication will be reported in the final version in either direction. Until then, we describe the automatic result as evidence consistent with label noise, not a clinician-verified estimate.
W5. Statistical Strength
We agree that the original statistical framing was too strong. The per-cell evidence is more consistent against Direct than against the strongest baseline, and we will present the latter as descriptive rather than confirmatory.
Because the same questions are evaluated across multiple backbones, the final version will use source-question-clustered uncertainty estimates, report exact corruption-specific denominators, and avoid broad claims of universal medical VQA robustness.
W6 & Q4. Gains Outside
choice_missingThe reviewer’s concern is supported by raw AnsF1: after removing
choice_missing, PICV is the top method in only 1 of 8 cells.However, raw AnsF1 compares systems operating at substantially different answer rates. At the same harmful-answer budget, PICV answers more questions than 6 of 7 baselines after removing
choice_missing:The same qualitative pattern holds on open-ended questions.
We therefore revise the claim to:
W7. Trivial-Policy Floors
We agree. We will report Always-Answer and Always-Abstain references beside the corresponding metrics and no longer use raw AnsF1 as the sole headline result.
Our primary comparisons instead fix the operating point:
Neither comparison can be improved merely by answering less.
W8. Manual Entity–Region Mapping
We agree. PICV uses a manually defined 62-entry entity–region map. It covers 175 of 357 invoked region claims; unmatched claims return
UNCLEAR.This fail-open behavior avoids map-only false
REFUTEDdecisions but reduces detection power for unseen entities. We will replace “no fine-tuning” with:We will also report mapping coverage and make no out-of-domain robustness claim.
Additional Evaluation
PICV reduces harmful answers from 69.4 to 41.4 per 100 queries, while the conditional accuracy of the answers it retains remains close to Direct answering (0.593 vs. 0.598). Overall answerable-case accuracy is lower when abstentions are counted as errors, so we will report accuracy, coverage, harmful answers, and false refusals jointly.
Holding claim-level evidence fixed, the deterministic rule also outperforms a prompted same-backbone aggregator at matched operating points. At equal coverage, it achieves higher AnsF1 and 2.25 fewer harmful answers per 100. We interpret this only as evidence that deterministic aggregation better preserves isolated negative evidence than the evaluated prompted judge.
The final version will add matched comparisons with the supervised aggregation head and a leakage-controlled selective-prediction baseline.