Focus, Align, and Diffuse: Time-Series-Aware Keyframe Diffusion for Cardiac Dynamic Synthesis from Sparse Observations

Junkai Liu, Haofan Wu, Nay Aung, Joao A. C. Lima, Steffen E. Petersen, Le Zhang

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. CardioFAD turns a single cardiac observation into a dynamic sequence with motion-salient keyframes and time-series guidance.

Abstract. Dense cardiac dynamics are essential for assessing cardiac function, yet in practice clinicians often observe only extremely sparse measurements. However, recovering full dynamics from such sparsity is a highly ill-posed problem due to the lack of temporal cues. While auxiliary time-series signals like ECG provide physiological guidance, effectively exploiting them is challenging due to the cross-modal representation gap and phase misalignment. In this work, we present CardioFAD, a Focus-Align-Diffuse paradigm that reformulates sparse cardiac dynamic synthesis as a recoverability-alignability anchor discovery problem. Our core insight is that resolving extreme temporal ambiguity requires a compact set of anchor states that are both sufficient to recover the visual trajectory and reliable for ECG-visual alignment. We therefore learn motion-salient keyframes under two complementary principles: trajectory sufficiency, which preserves trajectory-critical intra-modal motion content, and anchor alignment, which promotes consistent inter-modal correspondence at these anchors. We implement the Focus and Align modules optimized by the two aspects. Diffuse then performs two-stage generation by first synthesizing keyframes and subsequently interpolating the remaining frames. Extensive experiments on cardiac MRI and echocardiography videos demonstrate superior visual quality, temporal coherence, and improved functional consistency under the extreme one-shot regime.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
3 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:49 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

CardioFAD synthesizes cardiac dynamics from a single visual observation by learning motion-salient keyframes, aligning them with ECG or phase guidance, and generating the sequence in two diffusion stages. It reports consistent gains on CMR and ECHO datasets. The Focus–Align–Diffuse decomposition is clear, and the diagnostic analyses and learned keyframe alignment provide stronger evidence than a standard aggregate comparison alone.

The remaining questions are:

  1. On the ECHO datasets, the pseudo-ECG appears to be a patient-independent phase template. Separate gains from genuine patient-specific ECG information from those due to a generic phase prior and two-stage anchoring, and clarify which experiments support the ECG-aware claim.
  2. Clarify the intended clinical use of one-frame ECHO synthesis and the evidence for clinical fidelity. Discuss whether pathology-specific motion is preserved and how applying an EF regressor trained on real videos to generated videos affects interpretation. The paper should not imply diagnostic validity beyond the available evidence.

If the role of ECG is established and the clinical claims are appropriately scoped, I would be ready to support acceptance.

Final justification

The reviewers were generally positive, with two Accept and one Borderline Accept rating. The rebuttal adequately distinguishes patient-specific ECG gains on UKBB from generic phase guidance on ECHO, strengthens the robustness and functional-consistency evaluations, and appropriately limits the clinical claims. The remaining limitations are clearly acknowledged and do not outweigh the technical contributions. I therefore recommend acceptance.

Area Chair 5Kw1 · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

CardioFAD synthesizes cardiac dynamics from a single visual observation by learning motion-salient keyframes, aligning them with ECG or phase guidance, and generating the sequence in two diffusion stages. It reports consistent gains on CMR and ECHO datasets. The Focus–Align–Diffuse decomposition is clear, and the diagnostic analyses and learned keyframe alignment provide stronger evidence than a standard aggregate comparison alone.

The remaining questions are:

  1. On the ECHO datasets, the pseudo-ECG appears to be a patient-independent phase template. Separate gains from genuine patient-specific ECG information from those due to a generic phase prior and two-stage anchoring, and clarify which experiments support the ECG-aware claim.
  2. Clarify the intended clinical use of one-frame ECHO synthesis and the evidence for clinical fidelity. Discuss whether pathology-specific motion is preserved and how applying an EF regressor trained on real videos to generated videos affects interpretation. The paper should not imply diagnostic validity beyond the available evidence.

If the role of ECG is established and the clinical claims are appropriately scoped, I would be ready to support acceptance.

Final justification

The reviewers were generally positive, with two Accept and one Borderline Accept rating. The rebuttal adequately distinguishes patient-specific ECG gains on UKBB from generic phase guidance on ECHO, strengthens the robustness and functional-consistency evaluations, and appropriately limits the clinical claims. The remaining limitations are clearly acknowledged and do not outweigh the technical contributions. I therefore recommend acceptance.

1 comment
Authors · CommentOpenReview ↗

General Response

General Response

We sincerely thank the AC and all reviewers for their careful evaluation and constructive feedback. The meta-review identifies two remaining conditions concerning the attribution of ECG-related gains and the clinical use and scope of clinical-fidelity claims. Below, we map each condition to the corresponding new evidence and planned manuscript revisions.

We believe these additions directly respond to the two remaining questions identified in the meta-review by establishing the role of ECG and appropriately scoping the clinical claims.


I. Shared Strengths

  • Important problem and formulation (AC, AU6p, 7WCE)
  • Clear Focus–Align–Diffuse design (AC, 7WCE)
  • Strong controlled and diagnostic evidence (AC, EPkX, 7WCE)
  • Broad evaluation across CMR and ECHO (AC, AU6p)

II. Responses to key concerns

Key concerns Reviewers New evidence and response Commitment to revision
Attribution of ECG-related gains. Separate patient-specific ECG information from generic phase guidance and two-stage anchoring. AC-1; AU6p-Q2; EPkX-Q1; 7WCE-Q1 On UKBB, paired ECG improves PSNR from 29.24 with null ECG to 32.41, while correct subject pairing adds +1.29 dB over shuffled ECG. On ECHO, correct phase guidance and two-stage anchoring each outperform their matched controls. Thus, patient-specific ECG utility is supported only on UKBB; ECHO supports generic phase guidance and two-stage anchoring. Restrict patient-specific ECG claims to UKBB and describe ECHO consistently as phase-guided in the Abstract, Problem Formulation, Contributions, dataset-specific terminology, Conclusion, and Limitations.
Clinical use and scope of clinical-fidelity claims. Clarify the ECHO use case, pathology-specific motion, and interpretation of EF evaluation. AC-2; AU6p-Q1/Q3; EPkX-Q3; 7WCE-Q3 CardioFAD is intended for extreme sparse-observation reconstruction and data-centric applications, not routine cine replacement or standalone diagnosis. On EchoNet-Dynamic, the real-video oracle and CardioFAD achieve EF MAEs of 3.96 and 4.17, with a paired Gen–Real bias of 0.26. Direct motion analysis also improves area-curve MAE from 0.063 to 0.048, supporting preservation of functional and regional-motion differences. Present EF only as a functional-consistency proxy, add the EF-credibility and pathology-specific analyses, and explicitly remove implications of standalone diagnostic validity.

We again sincerely thank the AC and all reviewers for their thoughtful and constructive guidance.

Reviewer 7WCEOpenReview ↗
Rating
5/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes CardioFAD, a Focus–Align–Diffuse framework for synthesizing dense cardiac dynamics from extremely sparse visual observations, such as a single CMR slice/volume or a single ECHO frame, with auxiliary time-series signals such as ECG. The authors reformulate sparse cardiac dynamic synthesis as a recoverability–alignability anchor discovery problem. Specifically, the Focus module learns motion-salient keyframes under a Trajectory Sufficiency Principle, the Align module encourages keyframe-weighted ECG–visual alignment under an Anchor Alignment Principle, and the Diffuse module performs two-stage generation by first synthesizing keyframes and then interpolating non-keyframes. The method is evaluated on 3D+t CMR synthesis using UK Biobank and 2D+t ECHO synthesis using EchoNet-Dynamic and EchoNet-Pediatric. The reported results show consistent improvements over controllable video generation baselines and ECHO-specific baselines in PSNR, SSIM, LPIPS, FID, and FVD, with additional clinical evaluation using EF estimation on EchoNet-Dynamic.

Strengths and weaknesses

Main Strengths

  1. Well-motivated problem formulation. The paper addresses an important and challenging clinical problem: reconstructing full cardiac dynamics from extremely sparse observations. The formulation around temporal ambiguity, weak visual evidence, and ECG–visual phase misalignment is convincing.
  2. Clear and coherent method design. The Focus–Align–Diffuse pipeline is conceptually clean. The decomposition into keyframe discovery, cross-modal alignment, and two-stage generation makes sense for sparse dynamic synthesis. The framework is also visually well explained in Figure 2, where the pipeline is divided into input encoding, Focus, Align, and Diffuse stages.
  3. Keyframe learning is more principled than simple ED/ES or uniform anchors. The paper does not merely use predefined cardiac phases such as ED/ES. Instead, it learns anchors that are both trajectory-sufficient and ECG-alignable. The ablation shows that learned anchors outperform random, uniform, GT ED/ES, and GT ED/ES supplemented keyframes.
  4. Good diagnostic analysis. The principle-targeted diagnostics in Section 4.4 are a strong part of the paper. The authors separately analyze whether selected keyframes are trajectory-informative and whether they concentrate ECG–visual alignment, which provides more evidence than standard metric comparison alone.

Main Weaknesses

  1. The task remains fundamentally ill-posed, and the paper may overstate recoverability. Synthesizing an entire cardiac sequence from a single frame, slice, or volume is extremely underdetermined. Although ECG and learned anchors help, many possible anatomically plausible trajectories may correspond to the same sparse observation. The paper would benefit from more uncertainty-aware evaluation or multi-sample diversity analysis rather than mainly reporting deterministic fidelity metrics.
  2. The role of ECG is not equally convincing across datasets. For ECHO datasets without ECG, the paper uses a patient-agnostic canonical phase template as a weak pseudo-ECG surrogate. This is practical, but it weakens the central claim that CardioFAD effectively leverages real auxiliary ECG signals. In those settings, the gains may come more from learned cardiac phase priors and two-stage keyframe diffusion than from true ECG–visual alignment.
  3. Clinical fidelity evaluation is still indirect. EF estimation is useful, but it relies on a separately trained regressor rather than direct clinical annotations, segmentation-derived volumes, or expert assessment. The authors also acknowledge that assessing clinical fidelity of generated CMR without explicit annotations such as segmentation labels or ED/ES phases remains an open challenge.
  4. Baseline comparison could be stronger. The paper compares with controllable video generation baselines and several ECHO generation methods. However, for a NeurIPS-level submission, it would be helpful to include more specialized cardiac reconstruction, interpolation, or motion-modeling baselines where possible. Some baselines may not be designed for this exact extreme one-shot medical setting, making the comparison less definitive.
Questions
  1. How much of the performance gain comes from real ECG information versus learned cardiac phase priors, especially on ECHO datasets where pseudo-ECG templates are used?
  2. Does CardioFAD generate diverse plausible trajectories when sampling multiple times from the same sparse observation, or does it collapse to an average cardiac motion pattern?
  3. For CMR, can clinical fidelity be evaluated using downstream segmentation, volume curves, ED/ES timing, or strain-related metrics?
  4. How sensitive is the method to ECG noise, missing ECG segments, arrhythmia, or irregular cardiac cycles?
Limitations

Overall, I find this submission interesting and reasonably strong. The problem is important, the Focus–Align–Diffuse formulation is coherent, and the empirical results are convincing across multiple cardiac synthesis settings. However, I have some reservations. The clinical validity of generated dynamics remains only partially established, the role of real ECG guidance is less clear on datasets using pseudo-ECG, and the framework is currently quite specialized to periodic cardiac motion. The paper would be stronger with more direct clinical metrics, uncertainty analysis, and deeper evaluation under ECG misalignment or pathological rhythms.

Formatting concerns

No

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

The reviewer’s positive assessment of importance of the problem, the clear Focus–Align–Diffuse design, and our diagnostic analyses is greatly appreciated. We add ECG attribution and multi-sample diversity analyses while further clarifying the scope of our clinical claims.


Summary of Key Concerns and Main Responses

Key concerns Main responses
ECG vs. phase prior Patient-specific ECG gains are supported on UKBB; ECHO gains arise from generic phase guidance and two-stage anchoring.
Generation Diversity Multi-sample evaluation reveals reduced but better-localized residual uncertainty with improved fidelity and functional stability.
Clinical validity Current evidence supports functional consistency, not comprehensive diagnostic validity.

W1: Multi-sample uncertainty.

Please see Q2 below.


W2: Gains from pseudo-ECG.

Please see Q1 below.


W3: Clinical fidelity evaluation.

Please refer to Q3.


W4: Baseline comparison.

Thank you for the feedback on our baseline settings. We agree that cardiac reconstruction [1][2], interpolation [3][4], and motion-modeling [5][6] methods are relevant directions. However, these methods typically rely on undersampled acquisition measurements, multiple observed frames or endpoint phases, or full cine sequences, which are unavailable in our extreme single-observation setting. Direct adaptation would therefore require changing their original input assumptions and would not provide a faithful comparison. We will expand the camera-ready Related Work to discuss these methods and clarify the protocol differences, while restricting our empirical claims to approaches evaluated under matched sparse-observation conditions.


Q1: Gains from real ECG information versus learned cardiac phase priors.

We thank the reviewer for highlighting this issue. We agree that the role of temporal guidance differs across datasets: UKBB provides paired patient-specific ECG, whereas the ECHO datasets use only a shared, patient-agnostic phase template. Therefore, the ECHO experiments should not be presented as evidence of real ECG–visual alignment.

To separate these effects, we retrained CardioFAD under matched settings. On UKBB, we compare paired real ECG, subject-shuffled real ECG, a patient-independent canonical training ECG, and null ECG. On EchoNet-Dynamic, we compare the correct phase template, a random-offset template that breaks phase-to-frame correspondence, a null template, and a matched one-stage model using the correct template.

Table R1. Attribution of temporal guidance

Dataset Temporal condition Patient-specific PSNR ↑ SSIM ↑ LPIPS ↓ FID ↓ FVD ↓
UKBB Paired real ECG ✓ 32.41 0.885 0.064 59.96 736.01
UKBB Subject-shuffled real ECG ✗ 31.12 0.870 0.076 91.48 958.23
UKBB Canonical training ECG ✗ 30.74 0.862 0.083 98.77 1046.28
UKBB Null ECG ✗ 29.24 0.834 0.099 107.39 1281.46
EchoNet-Dynamic Correct phase template ✗ 27.73 0.596 0.067 26.92 137.70
EchoNet-Dynamic Random-offset template ✗ 25.59 0.563 0.085 37.93 217.08
EchoNet-Dynamic Null template ✗ 25.26 0.559 0.088 45.98 243.62
EchoNet-Dynamic Correct template, one-stage ✗ 25.14 0.556 0.089 46.82 232.17

As reported, UKBB exhibits a clear hierarchy from paired ECG to shuffled ECG, canonical ECG, and null ECG, showing that generic phase structure is useful while correct patient-specific pairing provides additional gains. On ECHO, the correct template outperforms the random-offset and null templates, and the two-stage model outperforms its matched one-stage counterpart, separating the contributions of valid phase conditioning and keyframe anchoring.

We commit to adding this analysis to the camera-ready version as Appendix C.2, Attribution of Temporal Guidance. Therefore, real patient-specific ECG provides additional gains beyond generic cardiac phase priors on UKBB, whereas the ECHO gains arise from valid generic phase conditioning together with two-stage keyframe diffusion.

To clarify the evidence scope, patient-specific ECG utility is supported only on UKBB, primarily by Table R1 and complemented by the ECG-removal and perturbation analyses in Table 13 and Appendix C.7. The ECHO results support only generic phase guidance and two-stage anchoring; we will revise the relevant claims and terminology throughout the manuscript accordingly.


Q2: Generation Diversity.

We appreciate the reviewer’s careful reading of our manuscript. We agree that one-shot cardiac synthesis is inherently one-to-many, and clarify that our notion of recoverability refers to trajectory reconstruction sufficiency rather than unique identification of the underlying motion. We therefore conduct the complementary analyses as follows.

  • Experimental setup. We additionally evaluated 100 EchoNet-Dynamic test cases, generating eight samples for each fixed sparse observation. We fixed the observed frame, observation index, pseudo-ECG, and hard top-K keyframes, while varying only the rectified-flow sampling seed.
  • Evaluation metrics. Avg. LPIPS evaluates average sample fidelity; Best-of-8 LPIPS evaluates coverage of the held-out realization; Pairwise LPIPS and normalized motion diversity quantify appearance and motion variation across samples; uncertainty–error ρ is the Spearman correlation between frame-wise sample disagreement and reconstruction error; EF MAE and within-case EF std. evaluate functional fidelity and stability.

Table R2. Conditional Fidelity–Diversity Analysis.

Method Avg. LPIPS ↓ Best-of-8 LPIPS ↓ Pairwise LPIPS Norm. motion diversity Uncertainty–error ↑ EF MAE ↓ Within-case EF std. ↓
CardioFAD (One-stage) 0.091 0.085 0.035 0.40 0.29 5.03 2.21
CardioFAD 0.070 0.064 0.025 0.27 0.50 4.21 1.35

CardioFAD shows lower pairwise appearance and motion diversity than the one-stage model, consistent with its phase-anchored design, which trades unconstrained variation for higher reconstruction fidelity and functional stability. We therefore do not claim that CardioFAD captures the complete conditional posterior. Importantly, its residual variation is better localized to difficult frames, as the uncertainty–error correlation increases from 0.29 to 0.50, while LPIPS, EF MAE, and within-case EF variability all improve. Hence, CardioFAD retains non-zero stochastic variation but prioritizes faithful and phase-consistent reconstruction over maximal diversity. We will add the full setup and results to the camera-ready version in Appendix C.6 as a new section entitled Conditional Fidelity–Diversity Analysis and acknowledge limited posterior coverage as a limitation.

In summary, CardioFAD produces lower yet more error-correlated residual variation, reflecting a deliberate fidelity–diversity trade-off rather than comprehensive posterior modeling.


Q3: Clinical fidelity for CMR.

Thank you for this important point. We agree that segmentation-derived volume curves, ED/ES timing, strain, and expert assessment would provide stronger clinical validation. The EF regressor is intended only as complementary functional evidence rather than a substitute for annotation-based evaluation. Reliable CMR assessment would require frame-wise expert segmentations and phase annotations, which are unavailable under our current evaluation protocol. Applying an off-the-shelf segmenter to generated CMR would remain indirect and could confound generation errors with segmentation-domain-gap errors. We will therefore clarify in the camera-ready version that our current CMR experiments assess spatiotemporal generation fidelity rather than comprehensive clinical validity, and explicitly identify annotation-based volumetric, timing, strain, and expert evaluation as important future work.


Q4: Sensitivity to ECG Perturbations.

Thank you for the constructive question. Appendix C.7 evaluates modality-specific perturbations. For CMR, we test Gaussian noise, missing leads, and temporal phase jitter. For ECHO, we test phase shifts, pseudo-ECG component dropout, and random segment masking. These experiments cover noise, desynchronization, and incomplete conditioning, but they preserve regular periodicity and do not model arrhythmia or variable R–R intervals. We therefore do not claim robustness to irregular rhythms and will explicitly note this limitation.


References

[1] Pan J, et al. Unrolled and rapid motion-compensated reconstruction for cardiac CINE MRI. 2024.

[2] Iijima L, et al. EchoPOSE: 6D Pose Estimation of Sparse Echocardiograms for Left-Ventricular 3D Shape Reconstruction. 2026.

[3] Zhou X, et al. A diffusion-driven temporal super-resolution and spatial consistency enhancement framework for 4D MRI imaging. 2025.

[4] Zhang J, et al. Temporal Modulated Multi-scale Deformation Fusion via Knowledge Distillation for 4D Medical Image Interpolation. 2025.

[5] Shen C, et al. Continuous 3D myocardial motion tracking via echocardiography. 2024.

[6] Bi N, et al. Segmorph: concurrent motion estimation and segmentation for cardiac mri sequences. 2024.

Reviewer EPkXOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The authors propose CardioFAD, reframing the task of "cardiac dynamic synthesis from extremely sparse samples (single frame/slice)" as a "recoverability-and-calibrability point-discovery problem." They employ two principles—TSP (Temporal Sufficiency) and AAP (Point-wise Consistency)—to self-supervise the learning of motion-salient keyframes, followed by a two-stage masked diffusion process that first generates keyframes and then performs interpolation. The method demonstrates consistent performance improvements across UKBB (CMR) and three echocardiography datasets.

Strengths and weaknesses

Strengths: The one-stage internal control rigorously isolates the sources of gain (shared tokenizer, backbone, and training settings), lending credibility to the method's effectiveness; the diagnostic experiments (Figs. 4 and 6) go beyond standard ablation studies to clearly explain why the method works; and the co-localization of keyframes with ground-truth ED/ES frames (achieving a Recall@K=8 of 99.1%) provides compelling evidence of clinical interpretability.

Weaknesses: While the title and abstract emphasize being "time-series-aware" or "leveraging ECG," three of the four datasets (specifically, all the ECHO datasets) actually utilize a "pseudo-ECG"—a deterministic cosine template shared across samples, normalized such that patient-specific information is mathematically cancelled out. This implies that the performance gains observed on the ECHO datasets likely stem from a purely visual/geometric mechanism—specifically, the combination of "cardiac phase priors" and "two-stage keyframe anchoring"—rather than from genuine cross-modal temporal information. The claim regarding "ECG" utility is supported solely by the UKBB dataset, which notably lacks statistical significance, validation using a frozen tokenizer, and comparisons based on equivalent computational resources.

Questions
  1. Regarding the gap between pseudo-ECG and real ECG: all three ECHO datasets utilize pseudo-ECG, yet Appendix B.3 reveals this to be a deterministic cosine template—shared across samples—where patient-specific information has been mathematically cancelled out via min-max normalization. This implies that the so-called "ECG–visual alignment" in ECHO actually aligns visual data with a single, universal curve identical for everyone. Could you provide experimental evidence demonstrating that the performance gains in ECHO truly stem from temporal conditioning, rather than from the purely geometric mechanism of "periodic phase priors combined with two-stage keyframe anchoring"?

  2. The baselines used for comparison in ECHO video generation are somewhat outdated: two of the three baselines cited (HeartBeat MICCAI'24, EchoNet-Synthetic MICCAI'24, and ECHOPulse ICLR'25) date back to 2024, yet there have been numerous DiT-based ECHO video generation studies published since 2025. Could you include one or two stronger baselines from 2025 or later to verify that the performance gains are not merely inflated due to comparisons against weaker baselines?

  3. Credibility of EF evaluation: The paper reports EF regression results in Tables 3 and 9. However, the EF regressor was trained on real videos and then applied to generated videos (Section B.4), raising two concerns: (a) the regressor's robustness to generation artifacts is unknown, potentially leading to systematic over- or under-estimation; and (b) the paper does not report the regressor's baseline performance on a real test set to serve as an upper-bound reference. Could you report the regressor's R²/MAE on real videos as an "oracle" upper bound and discuss the impact of the domain gap on the EF evaluation?

  4. Lack of statistical significance: The authors acknowledge in Checklist Q7 that error bars are absent. Given the marginal performance gap between CardioFAD (One-stage) and the strongest baseline (ECHOPulse) on the ECHO dataset, a single run is insufficient to substantiate a claim of superiority.

  5. Stability of keyframe selection: The straight-through Gumbel-Softmax top-K approach may exhibit high variance in selection when K is small and sequences are long, yet the paper lacks a stability analysis. Could you report the temporal consistency (e.g., IoU or temporal variance) of the selected keyframes across different random seeds?

  6. The co-adaptation shortcut associated with joint training was ruled out only for ECHO: the "frozen-tokenizer" validation (Table 8) was performed solely on EchoNet-Dynamic, whereas the UKBB dataset—a real-world ECG dataset where the TSP/AAP synergy most urgently needed to be tested—was omitted. Could the frozen-tokenizer experiment be conducted on UKBB to rule out the explanation that "the information content of keyframes is a product of the latent space being jointly shaped"?

Limitations

Yes

Final justification

The authors' rebuttal has satisfactorily addressed all of my concerns. While I feel there is still room to further polish some of the details, I am confident in the overall contribution and look forward to seeing this line of work developed further. I am therefore raising my score to 5.

Formatting concerns

N/A

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

We value the reviewer’s positive feedback. We add ECG attribution, EF reliability, multi-seed stability, and frozen-tokenizer experiments to address the key concerns. We remain open for any further discussion.


Summary of Key Concerns and Main Responses

Key concerns Main responses
ECG attribution Paired ECG provides additional gains beyond shuffled, canonical, and null guidance on UKBB.
EF credibility Added real-video oracle and paired agreement analyses; EF is interpreted only as a functional-consistency proxy.
Robustness and co-adaptation Multi-seed, keyframe-stability, and UKBB frozen-tokenizer results confirm stable gains.

Main weakness on ECG attribution: Please see Q1.


Statistical significance and frozen-tokenizer validation: Please see Q4 and Q6.


Q1: Gap between pseudo-ECG and real ECG.

Thank you for your concern. We agree that the ECHO pseudo-ECG is a universal, patient-independent phase template, and therefore the ECHO experiments should not be interpreted as evidence of patient-specific ECG utility.

To isolate temporal-guidance effects, we retrain CardioFAD under identical settings while varying only the condition. On UKBB Volume2Seq, we compare paired real ECG, subject-shuffled ECG, a patient-independent canonical ECG, and null ECG. Shuffling removes subject correspondence while preserving realistic ECG statistics, whereas the canonical ECG provides only a generic phase prior. On EchoNet-Dynamic, where real ECG data is unavailable, we compare the correct phase template, a random-offset template, a null template, and a matched one-stage model using the correct template. The random offset preserves periodic structure but disrupts phase-to-frame correspondence.

Table R1. Attribution of temporal guidance

Dataset Temporal condition Patient-specific PSNR ↑ SSIM ↑ LPIPS ↓ FID ↓ FVD ↓
UKBB Paired real ECG ✓ 32.41 0.885 0.064 59.96 736.01
UKBB Subject-shuffled real ECG ✗ 31.12 0.870 0.076 91.48 958.23
UKBB Canonical training ECG ✗ 30.74 0.862 0.083 98.77 1046.28
UKBB Null ECG ✗ 29.24 0.834 0.099 107.39 1281.46
EchoNet-Dynamic Correct phase template ✗ 27.73 0.596 0.067 26.92 137.70
EchoNet-Dynamic Random-offset template ✗ 25.59 0.563 0.085 37.93 217.08
EchoNet-Dynamic Null template ✗ 25.26 0.559 0.088 45.98 243.62
EchoNet-Dynamic Correct template, one-stage ✗ 25.14 0.556 0.089 46.82 232.17

The correct template consistently outperforms both the random-offset and null templates, demonstrating that the model benefits from correctly ordered temporal conditioning rather than merely receiving a universal periodic curve. Meanwhile, the two-stage model remains clearly better than the one-stage variant, confirming an additional contribution from our keyframe anchoring.

We will add this study as Attribution of Temporal Guidance. Therefore, the ECHO gains do not arise from patient-specific ECG information; they are attributable to valid generic temporal phase conditioning together with two-stage keyframe anchoring.

To clarify the evidence scope, patient-specific ECG utility is supported only on UKBB, primarily by Table R1 and complemented by the ECG-removal and perturbation analyses in Table 13 and Appendix C.7. The ECHO results support only generic phase guidance and two-stage anchoring; we will revise the relevant claims and terminology throughout the manuscript accordingly.


Q2: Baseline comparison.

Thank you for highlighting this issue. We conduct an updated literature review and find the following:

ControlEchoSynth [1] performs paired A4C-to-A2C video translation with full-video conditioning.

EchoLVFM [2] is evaluated on CAMUS under an ED-to-ES, single-frame and EF protocol.

Neither method is directly comparable to our full-cycle ECHO setting.

EchoVDiff [3] is a CVPR 2026 work that appeared after the NeurIPS 2026 deadline. We will discuss it and clarify its close relationship to our task. However, because no official implementation or checkpoint is publicly available at rebuttal time, a faithful empirical reproduction was not feasible.

EchoFlow [4] is also closely related, although it uses frame and EF conditioning, fixing 64-frame resampling rather than our frame and pseudo-ECG setting.

We will explicitly add and discuss these recent methods, add EchoFlow as a new quantitative baseline and treat EchoVDiff as concurrent work.


Q3: Credibility of EF evaluation.

Thank you for this important suggestion. We evaluate the same frozen EF regressor on the real test videos of all three ECHO datasets as an oracle reference in Table R2.

Table R2. Performance of the EF regressor on real test videos from ECHO datasets.

R² ↑ MAE ↓ RMSE ↓
EchoNet-Dynamic 0.83 3.96 5.31
EchoNet-Pediatric (A4C) 0.78 4.14 5.50
EchoNet-Pediatric (PSAX) 0.80 3.74 5.32

Relative to these oracle results, our generated videos show only modest degradation.

We further compare EF predictions on matched generated–real video pairs as shown below. The small positive biases indicate only slight EF overestimation and argue against substantial artifact-induced systematic shifts.

Table R3. EF predictions on matched generated–real video pairs.

Bias, Gen − Real Paired MAE ↓ Paired RMSE ↓
EchoNet-Dynamic 0.26 1.53 1.86
EchoNet-Pediatric (A4C) 0.25 1.73 2.05
EchoNet-Pediatric (PSAX) 0.39 1.87 2.20

Since the EF regressor is trained only on real videos, generation artifacts and the real-to-generated domain gap may affect its predictions. Therefore, the EF results should be interpreted as a functional-consistency proxy rather than direct diagnostic validation. The modest oracle degradation and small paired biases argue against a large systematic directional shift. We will add these analyses as Credibility of EF Evaluation.


Q4: Statistical significance.

Thank you for your insightful advice. As sugested, we train and evaluat the three methods using three independent random seeds. CardioFAD consistently outperforms ECHOPulse. On PSNR, the 2.08 dB improvement is larger than the across-seed variation, and a two-sided Welch’s t-test gives p<0.001, confirming statistical significance for PSNR. The one-stage variant remains below ECHOPulse on EchoNet-Dynamic, confirming the importance of our two-stage design. We will include these results in a new Appendix C.2, Multi-seed Robustness Analysis.

Table R4. Multi-seed robustness analysis.

Method PSNR ↑ SSIM ↑ LPIPS ↓ FID ↓ FVD ↓
ECHOPulse 25.60±0.19 0.567±0.003 0.081±0.004 37.24±2.5 194.19±11.5
CardioFAD (One-stage) 25.17±0.16 0.558±0.003 0.090±0.003 46.52±2.9 235.08±9.8
CardioFAD (Ours) 27.68±0.20 0.595±0.004 0.068±0.004 26.48±2.2 139.54±12.8

Q5: Stability of keyframe selection.

Thank you for pointing this out. As suggested, we conduct an additional temporal-consistency analysis:

  • We evaluated three independently trained CardioFAD checkpoints on the same test ECHO videos using deterministic top-K selection without Gumbel noise.
  • We averaged all pairwise comparisons across the three seeds and test samples.
  • We report exact IoU, tolerance-aware consistency within ±1 latent timestep, and matched temporal deviation normalized by the cardiac-cycle length. Random top-K selection with the same T and K serves as a reference.

Table R5. Temporal-consistency analysis

Selection Exact IoU ↑ Consistency@±1 ↑ Temporal deviation ↓
Random top-K 0.16 0.52 9.3%
CardioFAD across 3 seeds 0.55 0.90 2.9%

CardioFAD substantially exceeds random selection in both exact and tolerance-aware consistency, while reducing temporal deviation of the cardiac cycle. These results show that the physiological anchors remain highly consistent across independently trained models, indicating that keyframe selection is stable across random seeds. We commit to adding these results as Temporal Consistency of Keyframes.


Q6: Frozen-tokenizer experiment on UKBB.

Thank you for identifying this point. We conduct the frozen-tokenizer validation on UKBB Volume2Seq. The frozen variant outperforms the one-stage baseline, while joint training further improves performance, indicating that co-optimization enhances representation compatibility. Thus, the TSP/AAP-guided gains persist in a fixed, independently learned latent space, providing further evidence that the gains extend beyond latent-space co-adaptation.

Table R6. Frozen visual tokenizer validation on UKBB.

Method Latent MSE ↓ PSNR ↑ SSIM ↑ LPIPS ↓ FID ↓ FVD ↓
CardioFAD (One-stage) -- 30.51 0.861 0.082 82.48 1007.63
CardioFAD (Frozen Tokenizer) 0.024 31.82 0.877 0.073 75.09 857.93
CardioFAD (Joint Tokenizer) 0.019 32.41 0.885 0.064 59.96 736.01

References

[1] Kondori N, et al. ControlEchoSynth: Boosting Ejection Fraction Estimation Models via Controlled Video Diffusion. 2025.

[2] Oladokun E, et al. EchoLVFM: One-Step Video Generation via Latent Flow Matching for Echocardiogram Synthesis. 2026.

[3] Zhang J, et al. EchoVDiff: Cardiac-Cycle Echocardiography Video Generation from Arbitrary Single Frame. 2026.

[4] Reynaud H, et al. Echoflow: a foundation model for cardiac ultrasound image and video generation. 2025.

Reviewer AU6pOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes a time-series-aware keyframe diffusion framework for cardiac dynamic synthesis from sparse observations. This work incorporates multimodal inputs, including ECG and video sequences (MRI or Echo). The proposed framework has three components: (1) Focus, which identifies key frames; (2) Align, which fuses multimodal inputs by keyframe-weighted cross-modal alignment; and (3) Diffuse, which performs two-stage generation by first synthesizing keyframes and then interpolating the remaining frames. The method is evaluated on both 3D+t CMR and 2D+t Echo datasets.

Strengths and weaknesses

Strength:

  1. The authors address a technical challenge in sparse cardiac dynamic synthesis: a single visual observation does not provide enough temporal information to determine the full cardiac trajectory. The proposed recoverability-alignability formulation is interesting to explore complementary signals.
  2. The experiments are thorough and cover a broad range of settings, including 3D+t CMR synthesis and 2D+t ECHO video synthesis. The paper compares against multiple general video generation and Echo-specific baselines.

Weakness:

  1. The clinical motivation and practical impact of the task are not fully clear. While sparse CMR acquisition may be clinically meaningful due to acquisition cost and time, the motivation is less convincing for Echo video synthesis. In routine echocardiography, the temporal resolution is often already sufficient for studying cardiac dynamics. Therefore, it is unclear why synthesizing a full Echo video from a single frame is clinically necessary, or in what realistic clinical scenario this would be used.
  2. The relationship to video frame interpolation and video completion is not sufficiently discussed. Since the method generates missing frames from sparse observations and its second stage explicitly interpolates non-keyframes, relevant video frame interpolation, medical image interpolation, and conditional video completion methods should be discussed more thoroughly as part of the literature and potentially included as baselines.
Questions
  1. What is the main clinical use case for generating a full Echo video from a single frame? Since echocardiography usually has sufficient temporal resolution, it would be helpful to clarify when such synthesis would be needed in practice.

  2. For the Echo experiments, since no real ECG is available and a canonical phase template is used instead, how much of the improvement comes from patient-specific time-series guidance versus a generic phase prior?

  3. Does the method preserve pathology-specific motion patterns, such as regional wall motion abnormalities, abnormal EF, or atypical contraction/relaxation patterns? Are there subgroup analyses on abnormal cases?

  4. How sensitive is the method to the observed frame index? For example, does performance change significantly if the single observed frame is near ED, ES, or an intermediate phase?

  5. Are there failure cases where the learned keyframes are physiologically implausible or where the generated sequence has good visual quality but poor clinical consistency?

Limitations

The paper already acknowledges that 2D slice-to-sequence motion inference remains ambiguous and that clinical fidelity for CMR is difficult to assess without explicit annotations.

Final justification

The authors addressed most of my comments and I remain positive on the paper. Since there are still quite a few changes needed to fully address the comments (e.g. revise clinical utility claims, incorporate pathology motion study into the paper), I will maintain my original score.

Formatting concerns

N/A

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely thank the reviewer for recognizing our formulation and broad evaluation. In response, we clarify the ECHO use case and add temporal-guidance attribution and pathology-specific motion analyses.


Summary of Key Concerns and Main Responses

Key concerns Main responses
ECHO clinical use Clarified as sparse-observation reconstruction and synthetic-data generation, not routine cine replacement or diagnosis.
ECG vs. phase prior UKBB supports patient-specific ECG gains; ECHO supports generic phase guidance and two-stage anchoring.
Pathological motion Added EF-stratified and regional-motion analyses.

W1: Please see Q1.


W2: Related work on video frame interpolation and video completion.

Thank you for the significant suggestion. We agree that CardioFAD is related to video interpolation and conditional completion. However, it reconstructs a full cardiac sequence from extremely sparse observations and ECG guidance, rather than temporally adjacent or densely observed frames. We will expand the related work to discuss these directions. This discussion was previously shortened due to space constraints.


Q1: Clinical use for ECHO video.

Thank you for this thoughtful suggestion. We agree that routine cine echocardiography generally provides sufficient temporal resolution, and CardioFAD is not intended to replace standard ECHO acquisition.

  • Sparse-observation reconstruction. Recent studies have investigated reconstructing or animating complete cardiac dynamics from an arbitrary frame or other minimal spatial conditions, including [1-3].
  • Data-centric applications. ECHO video synthesis has also been used for rare-pathology enrichment and downstream disease detection, privacy-preserving data sharing, and training of sonographers and diagnostic models, as demonstrated by [4-6].

We will clarify that our ECHO synthesis represents an extreme sparse-observation task, rather than a replacement for routine cine ECHO or a standalone diagnostic reconstruction. These clarifications will be incorporated into the camera-ready Introduction.


Q2: Gains from patient-specific time-series guidance versus a generic phase prior.

Thank you for this valuable suggestion. We agree that the patient-independent pseudo-ECG cannot support a claim of patient-specific ECG utility. We therefore conduct a controlled attribution study in which only the temporal condition is changed under otherwise matched settings.

On UKBB, we compare paired real ECG, subject-shuffled ECG, a patient-independent canonical ECG, and null ECG. Shuffling preserves realistic ECG statistics while removing subject correspondence. On EchoNet-Dynamic, we compare the correct phase template, a random-offset template, a null template, and a matched one-stage model using the correct template.

Table R1. Attribution of temporal guidance

Dataset Temporal condition Patient-specific PSNR ↑ SSIM ↑ LPIPS ↓ FID ↓ FVD ↓
UKBB Paired real ECG ✓ 32.41 0.885 0.064 59.96 736.01
UKBB Subject-shuffled real ECG ✗ 31.12 0.870 0.076 91.48 958.23
UKBB Canonical training ECG ✗ 30.74 0.862 0.083 98.77 1046.28
UKBB Null ECG ✗ 29.24 0.834 0.099 107.39 1281.46
EchoNet-Dynamic Correct phase template ✗ 27.73 0.596 0.067 26.92 137.70
EchoNet-Dynamic Random-offset template ✗ 25.59 0.563 0.085 37.93 217.08
EchoNet-Dynamic Null template ✗ 25.26 0.559 0.088 45.98 243.62
EchoNet-Dynamic Correct template, one-stage ✗ 25.14 0.556 0.089 46.82 232.17

UKBB shows a clear hierarchy from paired ECG to shuffled, canonical, and null ECG, demonstrating that generic temporal structure is beneficial while correct patient-specific pairing provides additional gains. On EchoNet-Dynamic, the correct template outperforms random-offset and null templates, and the two-stage model outperforms its one-stage counterpart, separating the benefits of valid phase guidance and keyframe anchoring.

We will add this study as Attribution of Temporal Guidance. Patient-specific ECG provides additional value beyond generic phase priors on UKBB, whereas ECHO gains arise from valid phase conditioning and two-stage anchoring.

To clarify the evidence scope, patient-specific ECG utility is supported only on UKBB, primarily by Table R1 and complemented by the ECG-removal and perturbation analyses in Table 13 and Appendix C.7. The ECHO results support only generic phase guidance and two-stage anchoring; we will revise the relevant claims and terminology throughout the manuscript accordingly.


Q3: Pathology-specific motion patterns.

Thank you for the insightful comment. We conduct two complementary analyses as follows.

  • EF-stratified functional preservation.

We evaluated all test subjects in three EF groups: reduced EF, mildly reduced EF, and preserved-range EF. The same frozen EF regressor was applied, and we report the real-video oracle MAE, generated-video MAE, signed CardioFAD bias, and paired Gen–Real MAE.

Table R2. EF-stratified functional preservation

GT EF stratum n Real-video oracle MAE ↓ One-stage MAE ↓ CardioFAD MAE ↓ CardioFAD bias vs. GT Paired Gen–Real MAE ↓
Reduced, EF (≤ 40) 161 4.81 5.84 5.10 0.72 2.13
Mildly reduced, (40<EF<50) 125 4.49 5.29 4.65 0.58 1.79
Preserved-range, EF (≥ 50) 991 3.76 4.80 3.96 0.15 1.40
All test subjects 1,277 3.96 4.98 4.17 0.26 1.53

CardioFAD improves over One-stage in every EF stratum. Although the positive bias increases modestly toward lower-EF cases, even the largest shift remains well below the real-video oracle MAE, indicating only minor severity-dependent overestimation while preserving EF-related functional differences. CardioFAD therefore retains EF-related functional differences across severity groups.

  • Direct contraction and regional-motion consistency.

We further construct a stratified subset of 60 test subjects, with 20 cases from each EF stratum, and apply the same frozen LV segmenter. The 15 cases in the top quartile of real-video segmental-motion heterogeneity were additionally evaluated as a challenging regional-motion subset. Area-curve MAE measures the discrepancy between ED-normalized LV area trajectories over the complete cardiac cycle, thereby capturing contraction and relaxation consistency. Segmental-motion MAE measures the discrepancy between six A4C endocardial-segment shortening profiles from ED to ES.

Table R3. Direct motion preservation

Subset n Area-curve MAE ↓ One-stage Area-curve MAE ↓ CardioFAD Segmental-motion MAE ↓ One-stage Segmental-motion MAE ↓ CardioFAD
All stratified cases 60 0.063 0.048 0.119 0.097
Reduced EF 20 0.078 0.051 0.140 0.116
High regional-motion heterogeneity 15 0.095 0.067 0.182 0.141

CardioFAD reduces both errors across all evaluated subsets, with the improvements remaining pronounced in the two challenging subsets. CardioFAD therefore better preserves both global contraction–relaxation trajectories and heterogeneous regional motion. Together, the two analyses indicate that CardioFAD preserves EF-related severity differences and heterogeneous motion patterns rather than collapsing toward a population-average trajectory. We will add these results as Pathology-specific Motion Patterns.


Q4: Sensitivity to the observed frame index.

Thank you for raising this point. In our setup, the observed frame is randomly sampled across the cardiac cycle, and its temporal index is explicitly provided to the DiT. Thus, the reported evaluation includes observations near ED, ES, and intermediate phases. Moreover, removing the reference index degrades synthetic performance, confirming that CardioFAD uses this positional cue to adapt generation. We will clarify that our results demonstrate effectiveness with randomly located observations.


Q5: Potential failure cases.

Thank you for this important question. Our analyses do not reveal an obvious systematic failure pattern, but they cannot rule out sample-level physiological inconsistencies. In Fig. 6, over 85% of ED/ES frames lie within ±3 frames of a selected keyframe. In Fig. 4, keyframes concentrate at phases with both strong motion and reliable temporal alignment. Tables 3 and 9 show that improved visual quality is accompanied by better EF preservation. Nevertheless, these aggregate analyses cannot exclude occasional implausible keyframes or sample-level clinical inconsistencies. We will acknowledge this limitation and avoid implying that the method is failure-free or diagnostically reliable.


References

[1] Zhang J, et al. EchoVDiff: Cardiac-Cycle Echocardiography Video Generation from Arbitrary Single Frame. 2026.

[2] Wang J, et al. Controllable Echocardiogram Video Generation Driven by Fine-Grained Cardiac Motion. 2026.

[3] Nguyen V P, et al. Training-free condition video diffusion models for single frame spatial-semantic echocardiogram synthesis. 2024.

[4] Roshanitabrizi P, et al. Synthesis of Pathological Dual-Channel Color Doppler Echocardiograms for Equitable Diagnosis of Heart Diseases. 2025.

[5] Reynaud H, et al. Echonet-synthetic: privacy-preserving video generation for safe medical data sharing. 2024.

[6] Zhou H, et al. Onuvs: An online motion transfer framework with content-texture decoupling for high-fidelity ultrasound video synthesis. 2026.

Authors · CommentOpenReview ↗

Additional response to Q4 (Sensitivity to the observed frame index).

Thank you for this valuable suggestion. We agree that the original random-frame evaluation does not directly isolate sensitivity to the observed cardiac phase. We therefore conduct an additional phase-stratified evaluation on EchoNet-Dynamic. All ECHO videos are temporally resampled to 125 frames. For each test subject, we evaluate four matched observation-phase settings using the same trained checkpoint and inference protocol, while changing only the observed frame and its temporal index. The ED/ES annotations are used only to define the phase groups for this analysis and are never provided to the model. Using circular temporal indexing, the four settings are defined as follows:

  • near ED: frames within ±2 frames of the annotated ED reference frame, yielding a five-frame window;

  • near ES: frames within ±2 frames of the annotated ES reference frame, also yielding a five-frame window;

  • contraction: intermediate frames after the near-ED window and before the near-ES window along the ED-to-ES trajectory;

  • relaxation: intermediate frames after the near-ES window and before the next near-ED window along the ES-to-ED trajectory.

Table R4. Sensitivity to the observed-frame phase on EchoNet-Dynamic.

Observed-frame phase PSNR ↑ FVD ↓ EF MAE ↓
near ED 27.92 128.92 4.10
near ES 27.84 135.04 4.08
contraction 27.72 140.57 4.23
relaxation 27.68 144.82 4.26
Random observation 27.73 137.70 4.17

Near-ED and near-ES observations perform slightly better than contraction and relaxation observations. This ordering is qualitatively consistent with the Trajectory Sufficiency Principle, since motion-extremal states provide stronger constraints on the cardiac trajectory than intermediate phases. Nevertheless, the maximum variation remains small, only 0.24 dB in PSNR, 15.9 in FVD, and 0.18 in EF MAE, indicating that phase conditioning and two-stage anchoring largely compensate for less informative observation positions. These findings are consistent with the trajectory-sufficiency intuition while demonstrating that CardioFAD has only limited sensitivity to the observed-frame phase. We will add this analysis to the Appendix Sensitivity to the observed frame index.


We hope these additions address the remaining concerns, and we are happy to provide further analysis during the discussion period. We sincerely appreciate the constructive feedback, which has helped strengthen our manuscript.