potentialpaper

Calibeating Prediction-Powered Inference

Lars van der Laan, Mark J. van der Laan

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. We propose calibrated PPI: a simple post-hoc calibration step that turns a black-box score into a more efficient semisupervised mean estimator, while retaining valid inference.

Abstract. Prediction-powered inference (PPI) uses black-box predictions to improve estimation when labeled data are scarce but unlabeled data are abundant. However, prediction scores may be miscalibrated and need not provide efficient regression adjustments. We study semisupervised mean estimation and propose calibrated prediction-powered inference: calibrate the prediction scores using the labeled sample, then estimate the mean by averaging the calibrated predictions over the pooled covariate sample. This procedure requires no retraining, has a simple plug-in form, and admits an exact augmented inverse-probability weighting (AIPW) representation. We show that linear calibration is first-order equivalent to PPI++. For isotonic calibration, we establish asymptotic normality, valid Wald inference, and “calibeating” guarantees: isotonic calibration improves both prediction accuracy and the efficiency of the resulting regression adjustment within the class of monotone transformations. Moreover, further post-processing of the calibrated score cannot improve first-order efficiency. We also show that the original PPI estimator is a special case of AIPW and can be inefficient even when the predictions are accurate. Simulations, benchmark reproductions, and an LLM-evaluation application show that calibrated estimators often outperform PPI and are competitive with AIPW and PPI++.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
3 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:48 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper proposes calibrated prediction-powered inference for semisupervised mean estimation. The central idea is to post-process a black-box prediction score using the labeled sample and then average the calibrated predictions over the pooled labeled and unlabeled covariates. The paper shows that the resulting estimator has an AIPW representation. For linear calibration, it establishes first-order equivalence with PPI++; for isotonic calibration, it develops asymptotic normality, Wald inference, and optimality guarantees within the class of monotone transformations of the original score.

The reviewers agree that the connection between post-hoc calibration and prediction-powered inference is conceptually appealing. The procedure is simple, does not require retraining the underlying prediction model, and provides a useful interpretation of calibration as learning an improved regression adjustment. The theoretical development is substantial, particularly the equivalence results for linear calibration and the first-order optimality results for isotonic calibration.

However, the reviews identify a significant gap between the paper’s motivation and the evidence provided. The method is motivated by settings with scarce labeled data, yet the main guarantees are asymptotic and do not directly address the finite-sample behavior of fitting a flexible calibration map such as isotonic regression. In small labeled samples, estimation error and overfitting may offset the population-level efficiency gains established by the theory. The current experiments do not examine this issue systematically enough or provide sufficiently clear comparisons with strong alternatives such as AIPW and PPI++. The omission of more recent related methods such as RePPI further limits the empirical positioning.

A related concern is the distinction between asymptotic validity and finite-sample unbiasedness. Because the calibration function is estimated and evaluated using the same labeled observations, it is not sufficiently clear whether the estimator retains the finite-sample properties associated with standard AIPW/PPI constructions. This issue should be stated explicitly, and sample-splitting, cross-fitting, or leave-one-out alternatives should be considered. The current exposition also makes it difficult to distinguish exact finite-sample identities from asymptotic efficiency claims.

Finally, the paper is unusually dense, and the main methodological message is obscured by notation and by the distribution of key insights across multiple sections. The focus on mean estimation should also be presented more clearly as a limitation relative to the broader PPI literature.

The proposed connection is worthwhile and the theoretical analysis appears technically strong, but the current submission does not yet convincingly demonstrate that the method improves inference in the small-labeled-sample regime for which it is intended. This assessment could change if the author response provides a clear treatment of finite-sample bias, convincing small-sample experiments against AIPW/PPI++ and related recent baselines, and evidence that isotonic calibration does not substantially overfit in the relevant regimes.

Final justification

I have carefully read the authors' rebuttal and the reviewers' follow-up discussion. The rebuttal substantially addresses the main concerns raised during the initial review, including finite-sample behavior.

While one reviewer remains concerned about the gap between asymptotic theory and finite-sample practice, I believe the additional analyses and clarifications sufficiently address the major technical concerns. The connection between post-hoc calibration and prediction-powered inference is conceptually interesting, and the theoretical development is substantial.

Overall, I believe the strengths outweigh the remaining limitations, and I recommend Accept.

Area Chair 9F1u · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

This paper proposes calibrated prediction-powered inference for semisupervised mean estimation. The central idea is to post-process a black-box prediction score using the labeled sample and then average the calibrated predictions over the pooled labeled and unlabeled covariates. The paper shows that the resulting estimator has an AIPW representation. For linear calibration, it establishes first-order equivalence with PPI++; for isotonic calibration, it develops asymptotic normality, Wald inference, and optimality guarantees within the class of monotone transformations of the original score.

The reviewers agree that the connection between post-hoc calibration and prediction-powered inference is conceptually appealing. The procedure is simple, does not require retraining the underlying prediction model, and provides a useful interpretation of calibration as learning an improved regression adjustment. The theoretical development is substantial, particularly the equivalence results for linear calibration and the first-order optimality results for isotonic calibration.

However, the reviews identify a significant gap between the paper’s motivation and the evidence provided. The method is motivated by settings with scarce labeled data, yet the main guarantees are asymptotic and do not directly address the finite-sample behavior of fitting a flexible calibration map such as isotonic regression. In small labeled samples, estimation error and overfitting may offset the population-level efficiency gains established by the theory. The current experiments do not examine this issue systematically enough or provide sufficiently clear comparisons with strong alternatives such as AIPW and PPI++. The omission of more recent related methods such as RePPI further limits the empirical positioning.

A related concern is the distinction between asymptotic validity and finite-sample unbiasedness. Because the calibration function is estimated and evaluated using the same labeled observations, it is not sufficiently clear whether the estimator retains the finite-sample properties associated with standard AIPW/PPI constructions. This issue should be stated explicitly, and sample-splitting, cross-fitting, or leave-one-out alternatives should be considered. The current exposition also makes it difficult to distinguish exact finite-sample identities from asymptotic efficiency claims.

Finally, the paper is unusually dense, and the main methodological message is obscured by notation and by the distribution of key insights across multiple sections. The focus on mean estimation should also be presented more clearly as a limitation relative to the broader PPI literature.

The proposed connection is worthwhile and the theoretical analysis appears technically strong, but the current submission does not yet convincingly demonstrate that the method improves inference in the small-labeled-sample regime for which it is intended. This assessment could change if the author response provides a clear treatment of finite-sample bias, convincing small-sample experiments against AIPW/PPI++ and related recent baselines, and evidence that isotonic calibration does not substantially overfit in the relevant regimes.

Final justification

I have carefully read the authors' rebuttal and the reviewers' follow-up discussion. The rebuttal substantially addresses the main concerns raised during the initial review, including finite-sample behavior.

While one reviewer remains concerned about the gap between asymptotic theory and finite-sample practice, I believe the additional analyses and clarifications sufficiently address the major technical concerns. The connection between post-hoc calibration and prediction-powered inference is conceptually interesting, and the theoretical development is substantial.

Overall, I believe the strengths outweigh the remaining limitations, and I recommend Accept.

Reviewer mvd6OpenReview ↗
Rating
3/6
Confidence
3/5
Quality
2/4
Clarity
2/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

"Calibeating Prediction-Powered Inference" proposes using the labelled samples to fit a post-hoc calibration function in the prediction powered inference framework, and then constructing a mean estimator by averaging the calibrated predictions over both the labelled and unlabelled set.

Strengths and weaknesses

The main idea of the paper is a good idea, using post-hoc calibration before doing PPI makes sense and there are nice reductions showing that you recover existing estimators with this more general setting.

However, I think a fundamental weakness is that the paper's motivation is the small sample regime (PPI is typically performed because labelled samples are scarce) and every theoretical result in the paper is asymptotical.

I suspect some of the methods introduced in the paper would be very sensitive to overfitting. Typically, isotonic regression is known to overfit a lot with a few hundred samples, which is typically the regime in which PPI would be used (or with even fewer samples?).

While some methods in the paper are probably less sensitive to sample size (linear calibration for example), in my opinion the paper does not explore this regime empirically well enough. More careful finite sample evaluation is needed to support the claims of the paper. Generally I think the "Experiments" section is unclear, the baseline for relative comparisons should be changed, some methods appear to be lacking from some plots, the metrics are not well introduced.

Generally, I think the theoretical claims are a bit mis-leading, suggesting that you can only improve your estimator with post-hoc calibration, which is probably false in practice. From my understanding, Proposition 1 is saying that isotonic regression is calibrated on the samples it was fitted on. This is quite trivial, and does not imply it is calibrated in population, which is what actually matters (Similarly for Proposition 2). The rest of the results are asymptotic, which assumes the post-hoc calibration function are fitted on infinitely many samples. In practice the challenge with post-hoc calibration is avoiding overfitting, since you don't have many samples.

On a more cosmetic note:

  • AIPW is used everywhere in the paper while the full wording is only written in the appendix.
  • The mathematical notations seem overly complicated.
  • What is exactly the relative efficiency you report in your experiments?
Questions

Could you clarify the experiments? I am not convinced that your methods are actually beneficial in the small sample regime for now. What is precisely the relative efficiency you are reporting? I think AIPW or PPI++ should be used as a baseline for relative comparison, since PPI is known to be suboptimal. Also why is PPI++ not reported on Figure 2?

My understanding is that PPI and derivatives can be used for various statistical quantities (not only the mean), is your method restricted to mean estimation? Is this discussed as a limitation somewhere in the paper?

What would change my opinion of the paper is a clear and solid empirical comparison with PPI++ / AIPW, even in small data regimes. It doesn't have to improve upon these baselines everywhere but at least this should be explored and discussed.

I think the paper should frame the theoretical results better, to clarify the setting in which they apply vs the setting of PPI, and discuss the limitations mentioned earlier.

Limitations

I don't think that the risk of overfitting in the small data regime is properly discussed in the paper, while this appears to me as the main limitation, since the motivation behind PPI is this regime.

Same thing for the fact that the paper seems entirely focused on mean estimation, versus other methods that can cover various quantities.

Final justification

While I think the main idea of the paper is elegant, I still believe

(1) there is a mismatch between theoretical results and practical scenarios where the method would be applied.

(2) the paper is often unclear and hard to read.

(3) the empirical evaluation is not thorough / clear enough to convince me of the practical impact of the idea developed in the paper.

(4) some of the limitations in applicability and scope raised by the reviewers are not discussed or fully addressed.

Therefore I will keep my score unchanged.

Formatting concerns

/

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Small-sample comparison and isotonic overfitting

We agree that our original experiments did not make the small-nn tradeoffs easy to assess. We therefore compared the labeled mean, PPI, PPI++, augmented inverse-probability weighting (AIPW), linear calibration, smooth monotone calibration, and isotonic calibration from n=20n=20 to n=1200n=1200, including leave-one-out (LOO) versions of linear and isotonic calibration. We used N=16nN=16n, the two score settings from our simulation, and 1,000 repetitions per setting.

The table reports RMSE divided by the RMSE of the labeled mean, so values below one are better:

method mild n=20n=20 mild n=1200n=1200 strong n=20n=20 strong n=1200n=1200
Labeled mean 1.000 1.000 1.000 1.000
PPI 0.579 0.610 0.668 0.652
PPI++ 0.610 0.601 0.684 0.652
AIPW 0.572 0.602 0.679 0.664
LinearCal 0.589 0.600 0.657 0.622
LinearCal-LOO 0.578 0.600 0.651 0.622
MonoSpline 0.562 0.601 0.617 0.613
IsoCal 0.566 0.605 0.597 0.609
IsoCal-LOO 0.621 0.606 0.661 0.609

These results do not show uniform dominance, nor do we claim it. They do show that calibration remains useful with very few labels. At n=20n=20, the best calibration RMSE ratios are 0.5620.562 in the mild setting and 0.5970.597 in the strong setting. Under strong distortion, linear, smooth monotone, and isotonic calibration each have lower RMSE than PPI++ at all seven sample sizes.

The concern that isotonic regression may overfit at small nn is reasonable, but at n=20n=20, IsoCal's RMSE remains below that of both PPI++ and the labeled mean in both score settings. Its finite-sample weakness is interval coverage: at n=20n=20, the nominal 95% coverage is 0.8140.814--0.8710.871 for IsoCal and 0.9050.905--0.9250.925 for IsoCal-LOO. However, IsoCal-LOO has lower RMSE in only one of the 14 settings. LinearCal-LOO is more favorable, lowering RMSE in all 14 settings, although only by 0.010.01\\%--1.991.99\\%. Thus LOO is useful for reducing label reuse and improving coverage, but it is not uniformly better in RMSE.

AIPW, PPI++, and the reported metrics

AIPW and PPI++ were already included in Figure 1. Figure 2 was restricted to the calibration methods. We agree that the layout and changing reference comparisons made this unnecessarily difficult to see, but the baselines were not omitted. To remove the other ambiguity, our empirical relative efficiency is

V^refV^method,\frac{\widehat V_{\mathrm{ref}}} {\widehat V_{\mathrm{method}}},

so values above one favor the method. The values in the table above are RMSE ratios, not relative efficiencies. We agree that the notation and changing reference methods obscured these comparisons; the RMSE ratios above all use the labeled mean as the single reference.

RePPI comparison

We also compared with the mean-estimation version of RePPI using both a random forest and a cross-validated neural network, following its sample-splitting and coefficient-estimation procedure. Across the 14 settings, RePPI-RF has lower RMSE than PPI++ once, while RePPI-MLP-CV does so five times; neither has lower RMSE than MonoSpline. The neural version is unstable at n=20n=20, with RMSE ratios 1.4501.450 and 9.6909.690; for n≥50n\ge50, its ratio ranges from 0.5760.576 to 0.6680.668.

What Proposition 1 and the asymptotic theory establish

We agree that Proposition 1 establishes empirical, not population, calibration. Its role is to show residual orthogonality and the exact equivalence between our plug-in estimator and an AIPW estimator. It is not the basis for our population claim. The later results establish convergence to the population isotonic projection, asymptotic linearity, and Wald inference. We therefore do not claim that Proposition 1 implies population calibration or finite-sample improvement.

More generally, using the same labeled outcomes to fit and evaluate a calibrator can introduce finite-sample bias. For a fixed score, AIPW is exactly unbiased; for our same-sample linear and isotonic fits, our results establish asymptotic linearity without requiring sample splitting. The small-nn experiment above is needed precisely because an asymptotic theorem does not settle the finite-sample bias--variance tradeoff.

Scope: mean estimation and randomized trials

We deliberately focus on semisupervised mean estimation, which is the most common use case of PPI. This scope includes mean outcomes within each treatment arm and therefore average treatment effects in randomized trials. We do not consider general M-estimation, and we do not claim that our isotonic results extend unchanged to that setting.

Reviewer mvd6 · CommentOpenReview ↗

Thanks for the rebuttal.

While I think the main idea of the paper is elegant, I still believe (1) there is a mismatch between theoretical results and practical scenarios where the method would be applied. (2) the paper is often unclear and hard to read. (3) the empirical evaluation is not thorough / clear enough to convince me of the practical impact of the idea developed in the paper. (4) some of the limitations in applicability and scope raised by the reviewers are not discussed or fully addressed.

Therefore I will keep my score unchanged.

Reviewer vZb8OpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
2/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes to calibrate "prediction" scores used in AIPW/PPI type estimators on the labeled training data. Then simply averaging the resulting scores over all data is an estimate of the overall mean. Some theoretical results, in particular for isotonic calibration, show that with the right asymptotic assumptions, the calibration converges to the ideal isotonic model, and the modified estimator to the estimator based on this ideal model. Simulations and real data analysis show the (generally modest) gains from calibration.

Strengths and weaknesses

I find the general idea interesting, and the analysis quite serious. The paper is not easy to read, but it covers many interesting aspects of the problem, including the asymptotic variance expansion etc.

On the negative side, I have some general doubt about the importance and impact of this idea, punctuated by the minimal gains compared to the best of labeled-only and PPI variants in empirical work. I do not find the idea itself particularly innovative or striking, so the value proposition has to be quite strong.

More specifical concerns:

  1. The very dense writing style makes the paper quite hard to follow, for me at least. One aspect is lots of notation, another is using undefined terms. Even though it's all explained later, a sentence like "AIPW and PPI give valid inference" in the abstract is not inviting.
  2. An important property of AIPW is that they are unbiased, as rightly noted in Sec. 2. The current calibration framework loses this unbiasedness AFAIU. This is not explicitly mentioned, except in hints in the empirical part, maybe because the authors think it is obvious. I think this is a major concern.
  3. The asymptotic assumption n/M→ρ0>0n/M \rightarrow \rho_0 >0 seems questionable to me. The whole point seems to be having lots of unlabeled data, so isn't the asymptotics where n/M→0n/M \rightarrow 0 more relevant? Basically with the current asymptotics simple labeled mean converges at Op(M−1/2)O_p(M^{-1/2}) already
Questions
  1. Why not consider using data splitting or some LOOCV variant for calibration? Then the results would maintain unbiasedness
  2. The bias issue should be discussed more explicitly and clearly in my view
  3. Why the term calibeating? I find it quite confusing and not very helpful. It looks like a typo at first, then I learned from the text about the previous calibeating work, but there is no real connection to calibeating that I can see except a vague association
  4. Is it obvious that the isotonic version is (asymptotically) better than the labeled mean without any assumption on the true relationship? I think it is from Corollary 2 but for thick readers like me may be better to spell it out
Limitations

Yes

Final justification

I was quite satisfied with the authors' responses. While doubts about practical significance and writing style persist, I decided to raise my overall rating to weak accept (4)

Formatting concerns

None

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for recognizing the interest of the idea and the care of the theoretical analysis, and for their valuable feedback.

We agree that the construction is simple: it combines PPI with post-hoc model calibration, and we do not claim that either ingredient is new. The new point is that calibration can improve the variance reduction achieved by PPI, rather than only prediction quality, and that this improvement can be characterized sharply. We also believe the first-order equivalence between PPI++ and linear calibration is interesting in its own right, as it connects PPI++ to standard OLS and gives its scaling step a familiar regression interpretation.

We agree that these contributions require clear empirical support. Our new comparison across sample sizes finds modest differences when the score is already well scaled, but substantial gains under strong miscalibration. In that regime, linear, isotonic, and smooth monotone calibration outperform PPI++ at all seven sample sizes.

Finite-sample bias, splitting, and leave-one-out calibration

We agree that reusing labeled outcomes to fit the calibrator can introduce finite-sample bias. This issue is not unique to our method: PPI++ also estimates its scaling coefficient from the same labeled outcomes and is therefore generally not exactly unbiased in finite samples. Equation (12) controls the resulting error:

Op(n−2/3)+Op(n−1/3N−1/2).O_p(n^{-2/3}) + O_p(n^{-1/3}N^{-1/2}).

When NN is at least of the same order as nn, this is Op(n−2/3)O_p(n^{-2/3}). Sample splitting is therefore not needed for asymptotic validity, although the remainder may still matter at very small nn, particularly when isotonic regression overfits.

In the revision, we will add a focused section on small-sample behavior and present leave-one-out calibration as an optional modification that restores finite-sample unbiasedness. We will also include a new small-sample experiment, detailed below, to examine its effects on bias, coverage, and RMSE. The results show that leave-one-out calibration can substantially improve coverage at very small sample sizes, although the accompanying variance increase means that it does not uniformly improve RMSE.

Specifically, we will add the following leave-one-out version, where we fit the calibrator using out-of-fold predictions obtained via the jacknife, which provides unbiased mean estimators because the calibrated prediction used for observation ii does not depend on YiY_i.

We evaluated leave-one-out calibration in a new synthetic experiment using the same binary-outcome design as our existing simulation. We considered mildly and strongly miscalibrated prediction scores, varied the labeled sample size from n=20n=20 to n=1200n=1200, set N=16nN=16n, and used 1,000 replications per setting. We compared the original and leave-one-out linear and isotonic estimators with the labeled mean, PPI, PPI++, and AIPW.

At n=20n=20, leave-one-out calibration improves isotonic coverage: across the two score settings, coverage increases from values between 0.8140.814 and 0.8710.871 to values between 0.9050.905 and 0.9250.925. The results also show a bias-variance tradeoff: LinearCal-LOO lowers RMSE in all 14 sample-size and score settings, by between 0.01% and 1.99%, whereas IsoCal-LOO lowers RMSE in only one setting and can increase it by up to 10.66%. As the sample size grows, the original and leave-one-out estimators become nearly indistinguishable.

Allowing the labeled fraction to vanish

We agree that the theory should also allow ρn=n/(n+N)\rho_n=n/(n+N) to converge to zero. Our theory can be extended to handle this regime with only minimal modifications. A single theorem covers both regimes if we normalize by n\sqrt n rather than n+N\sqrt{n+N}. In particular, for isotonic calibration, we now show that if ρn→ρ∈[0,1)\rho_n\to\rho\in[0,1), then, under the same conditions as our current result,

n(ψ^iso−ψ0)⇒N(0,Var(Y−q0iso(X))+ρVar(q0iso(X))),\sqrt n ( \widehat\psi_{iso}-\psi_0 ) \Rightarrow N( 0, Var(Y-q_0^{iso}(X)) + \rho Var(q_0^{iso}(X)) ),

where q0isoq_0^{iso} denotes the population isotonic calibration.

For ρ>0\rho > 0, this is our current theorem rescaled from n+N\sqrt{n+N} to n\sqrt n. For ρ=0\rho=0, the second variance term disappears. We will state the theorem in this unified form.

Comparison with the labeled mean

We will make this comparison more explicit in the revision by adding a precise corollary.

Because constants belong to the monotone class, the isotonic-calibrated plug-in estimator is no less efficient than the labeled mean. Under n\sqrt n scaling, the labeled mean has asymptotic variance Var(Y)Var(Y), whereas isotonic calibration has the variance displayed above. The difference is

Var(Y)−[Var(Y−q0iso(X))+ρVar(q0iso(X))]=(1−ρ)Var(q0iso(X))≥0.Var(Y) - [ Var(Y-q_0^{iso}(X)) + \rho Var(q_0^{iso}(X)) ] = (1-\rho) Var(q_0^{iso}(X)) \geq 0.

When ρ>0\rho > 0, both estimators are Op((n+N)−1/2)O_p((n+N)^{-1/2}), but equal rates do not imply equal precision. We can show that isotonic calibration has strictly smaller asymptotic variance whenever the population isotonic calibration is nonconstant. When ρ=0\rho=0, both estimators are Op(n−1/2)O_p(n^{-1/2}), and the variance reduction is exactly Var(q0iso(X))Var(q_0^{iso}(X)). No monotonicity assumption on the true conditional mean is required.

Why we use "calibeating"

We use "calibeating" intentionally. Here, it means that the isotonic fit is calibrated and that the resulting mean estimator has, asymptotically, no larger variance than any estimator based on a monotone transformation of the score. Because the original score corresponds to the identity transformation, the isotonic estimator therefore asymptotically improves upon, or matches, the AIPW estimator based on the original score. More broadly, we use "calibeating" informally to describe achieving calibration together with another desirable property, such as improved accuracy or reduced variance, at no asymptotic cost. We will define this usage more carefully in the revision.

Reviewer vZb8 · CommentOpenReview ↗

I appreciate the detailed and thoughtful response, which touches on my specific concerns and addresses some of them convincingly - specifically the vanishing fraction issue. I still don't see the good reason to use "calibeating" but this is not a major point.
Overall the main strong points (reasonable idea, strong theory) and main concerns on overall significance and style mostly persist. For now I maintain my score, but I am close to the boundary between 3 and 4, so I may reconsider during the reviewers-AC discussion period.

Reviewer g4M9OpenReview ↗
Rating
4/6
Confidence
4/5
Quality
4/4
Clarity
2/4
Significance
4/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper studies semi-supervised estimation of a population mean in a missing-outcome setting, where a relatively small labeled sample is accompanied by a much larger unlabeled sample and a black-box prediction score. Although standard AIPW/PPI estimators remain valid when the prediction model is mis-specified, their variance can be unnecessarily large when the score is poorly aligned with the numerical scale of the outcome.

The paper proposes calibrated prediction-powered inference, which uses the labeled sample to post-hoc calibrate the black-box score and then averages the calibrated predictions over the pooled labeled and unlabeled covariates. Because the calibration class contains constants, the fitted residuals have empirical mean zero, and the resulting plug-in estimator admits an exact AIPW representation. Thus, the proposal is best viewed not as abandoning the debiasing structure of PPI/AIPW, but as using calibration to learn a better regression adjustment while retaining valid first-order inference.

The paper develops the method and asymptotic theory for two common calibration strategies. For linear calibration, it establishes first-order equivalence with PPI++ and relates the estimator to classical prognostic-score adjustment and TMLE. For isotonic calibration, it proves asymptotic linearity and normality, valid Wald inference, optimality among monotone transformations of the original score, and a “calibeating” result showing that no further post-processing of the fitted isotonic score yields an additional first-order improvement. The empirical evaluation includes controlled simulations, reproduced ppi_py mean-estimation benchmarks, and public LLM-evaluation data. Across these experiments, calibrated estimators often substantially outperform raw PPI and are competitive with or better than AIPW and PPI++, especially when the proxy score is badly scaled.

Strengths and weaknesses

Strengths: The connection between PPI and post-hoc calibration is insightful. It offers a simple way to improve the regression adjustment using labeled data without retraining the underlying predictor. The asymptotic analysis is fairly comprehensive for both linear and isotonic calibrated PPI. In particular, the paper establishes equivalence to PPI++ in the linear case and first-order optimality within monotone transformations in the isotonic case. The TMLE interpretation of linear calibration is conceptually useful. It places the proposed estimator within a broader semiparametric framework and clarifies the role of calibration as a targeting step. Weaknesses: The benchmark selection is incomplete. PPI++ is no longer the most recent development in this literature, and RePPI (Ji, Lei, and Zrnic, 2025) would be a more relevant comparator; although its notion of semiparametric efficiency differs from that in this paper, omitting it makes the empirical comparison less comprehensive. The presentation of the method and theory is somewhat difficult to follow. Key connections among calibration, AIPW/PPI, and the proposed plug-in estimator are introduced across several sections, creating a substantial barrier for readers who are not already familiar with both literatures.

Questions

Post-hoc calibration has mainly been used to adjust ML predictions, especially when complex neural networks preserve the correct ordering but misrepresent the magnitude. In this setting, order-preserving methods such as Platt scaling and isotonic calibration are naturally effective. Do LLM-generated predictions exhibit the same “correct ordering but inaccurate magnitude” structure? If not, does this weaken the compatibility between calibration methods and the PPI setting?

Limitations

Yes.

Final justification

The paper presents an insightful conceptual connection between post-hoc calibration and prediction-powered inference, supported by a fairly comprehensive theoretical analysis. The experiments further consider a label-scarce setting in which only 1/171/17 of the observations are labeled, providing useful empirical evidence for calibrated PPI when labeled data are limited. Nevertheless, some concerns remain: the paper is difficult to read, and the method focuses exclusively on mean estimation, limiting its broader applicability. Overall, I believe the strengths outweigh these limitations, and I therefore maintain my score of 4.

Formatting concerns

None.

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

RePPI comparison

We agree that a direct comparison with RePPI is useful. We already cite Ji et al. and distinguish RePPI from our method, but we did not include a head-to-head experiment.

We implemented the mean-estimation version of RePPI with both a random forest (RePPI-RF) and a cross-validated neural network (RePPI-MLP-CV). We followed RePPI's three-way sample-splitting and coefficient-estimation procedure, using a 100-tree random forest and a neural network whose architecture and penalty were selected by cross-validation within each training fold. We checked the shared neural-network components against the public implementation; the random-forest and cross-validation variants follow the current paper.

We compared these methods with PPI++, linear, isotonic, and smooth monotone calibration over n∈20,50,100,200,400,800,1200n\in\\{20,50,100,200,400,800,1200\\}, with N=16nN=16n and 1,000 repetitions in each of the two score settings from our simulation. The table reports RMSE divided by labeled-mean RMSE; smaller is better.

score setting nn RePPI-RF RePPI-MLP-CV PPI++ LinearCal IsoCal MonoSpline
mild 20 1.063 1.450 0.610 0.589 0.566 0.562
mild 200 0.655 0.604 0.599 0.599 0.598 0.590
mild 1200 0.681 0.602 0.601 0.600 0.605 0.601
strong 20 0.809 9.690 0.684 0.657 0.597 0.617
strong 200 0.639 0.590 0.633 0.591 0.584 0.585
strong 1200 0.652 0.622 0.652 0.622 0.609 0.613

RePPI-RF improves on the labeled mean in 13 of 14 settings, but has lower RMSE than PPI++ in only one. RePPI-MLP-CV has lower RMSE than PPI++ in five settings. For n≥50n\ge50, its RMSE ratio ranges from 0.5760.576 to 0.6680.668. At n=20n=20, however, fitting the neural network on very few outcomes can produce a nearly constant prediction and an unstable coefficient, which explains the two large RMSE ratios in the table. Neither RePPI version has lower RMSE than the smooth monotone calibrator in these experiments. We do not interpret this as a general failure of RePPI: it is a broader method designed to learn flexible relationships, whereas our results concern simple one-dimensional calibration and its sharper guarantees.

Do LLM scores need to preserve ordering?

On the LLM question, correct ordering is not required for AIPW validity. For a score fixed independently of the evaluated outcomes, the AIPW estimator is exactly unbiased regardless of the score's ordering or scale. For a calibrator fitted on the same outcomes, our guarantee is asymptotic rather than exact finite-sample unbiasedness. Ordering matters for efficiency: if the score contains no useful monotone signal, isotonic calibration approaches a constant and offers little gain. We do not assume that every LLM evaluator has the desired ordering.

The ArmoRM scores in our MATH experiment are well ordered by observed accuracy. The outcome rate increases across all twelve score bins, from 0.0780.078 in the lowest bin to 0.9200.920 in the highest. Fitting the calibrator on 100 examples reduces held-out prediction MSE from 0.46830.4683 to 0.20200.2020, a 56.956.9\\% reduction. Thus, in this application, the score is well ordered but badly scaled; we do not make that claim for LLM scores in general.

Relationship to PPI and AIPW

We also agree that the relationship among the methods was harder to see than it should have been. All three methods combine predictions with a labeled residual correction, but they use the score differently: PPI averages the raw prediction over the unlabeled sample, PPI++ estimates a linear scale, and our estimator averages a calibrated score over the pooled sample. Our plug-in estimator is algebraically identical to its AIPW form.

Reviewer g4M9 · CommentOpenReview ↗

Thank you for the detailed rebuttal. The additional comparisons with RePPI adequately address my concern regarding benchmark coverage and provide a clearer empirical positioning of the proposed calibration methods. I also appreciate the clarification that correct ordering of LLM scores is not required for AIPW validity, but primarily affects the potential efficiency gains, together with the supporting evidence from the MATH/ArmoRM experiment. These responses resolve my questions, and I have no further comments. I will maintain my score.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…