ViCoR: Estimating Visual Necessity via Counterfactual Residuals for Multimodal Medical Data Selection
Haotian Gan, Yudong Li, Xintian Li, Jiarui Han, Weidong Tang
NeurIPS 2026
TL;DR. ViCoR identifies medical examples where visual evidence matters most, helping vision-language models learn more reliable visual reasoning.
Abstract. Medical vision-language models often exhibit hidden stratification, where high overall performance masks failures on subtle visual findings and overlapping clinical conditions. We trace this failure mode to modality imbalance during fine-tuning, where strong linguistic priors can suppress visually grounded learning and induce plausible but weakly grounded rationales. Existing data selection methods usually score image-text pairs as holistic units, without separating visually necessary samples from shortcut-solvable ones. To address this problem, we propose ViCoR, a counterfactual-residual-based data selection method for Med-VLM fine-tuning. ViCoR estimates visual necessity through image-dependent optimization residuals, calibrates the resulting scores with medical supervision compatibility, and constructs a diversity-aware fine-tuning subset. Across two backbones, four external generalization benchmarks, and one multi-disease robustness benchmark, ViCoR-selected 20% subsets achieve the strongest average performance compared with full-data fine-tuning and selection baselines. Gradient-level analysis and perturbation audits further show that ViCoR enriches image-dependent training signals and strengthens image-level and evidence-region dependence. The code will be available at https://github.com/htgan-ai/ViCoR.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:43 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper is well motivated, clearly written, and supported by extensive experiments across multiple backbones, benchmarks, and ablations. The gradient residual formulation is intuitive, and the perturbation studies provide evidence that ViCoR improves visual dependence.
The largest concern is the insufficient discussion and comparison with the existing Visual Information Gain (VIG) [1] based selection method. Since both methods aim to identify visually necessary samples, the paper should clearly distinguish their motivations, technical differences, and empirical advantages. The absence of VIG-related analysis makes it difficult to evaluate the novelty and unique contribution of ViCoR.
[1] Focusing Where Vision Matters: Selective Training for Large Vision Language Models via Visual Information Gain.
Final justification
The paper proposes a first-order method and demonstrates its effectiveness on multiple datasets. One limitation is that the motivation does not clearly explain why the proposed first-order approach is necessary or preferable compared with zero-order methods. I recommend that the authors address this issue in the camera-ready version by providing a clearer justification.
Read meta-review
Meta-review
The paper is well motivated, clearly written, and supported by extensive experiments across multiple backbones, benchmarks, and ablations. The gradient residual formulation is intuitive, and the perturbation studies provide evidence that ViCoR improves visual dependence.
The largest concern is the insufficient discussion and comparison with the existing Visual Information Gain (VIG) [1] based selection method. Since both methods aim to identify visually necessary samples, the paper should clearly distinguish their motivations, technical differences, and empirical advantages. The absence of VIG-related analysis makes it difficult to evaluate the novelty and unique contribution of ViCoR.
[1] Focusing Where Vision Matters: Selective Training for Large Vision Language Models via Visual Information Gain.
Final justification
The paper proposes a first-order method and demonstrates its effectiveness on multiple datasets. One limitation is that the motivation does not clearly explain why the proposed first-order approach is necessary or preferable compared with zero-order methods. I recommend that the authors address this issue in the camera-ready version by providing a clearer justification.
3 comments
Thank you for the additional comparison. The distinction between VIG as a zeroth-order prediction signal and ViCoR as a first-order optimization signal is clear. However, this distinction alone does not establish why the more expensive ViCoR is needed.
The empirical results show mixed advantages: ViCoR performs better on three external benchmarks and the average, but VIG is better on GMAI-MMBench and on both multi-disease metrics. Given that ViCoR requires two backward passes per sample and introduces several additional components, the current results do not demonstrate a clear cost–performance advantage over VIG. Moreover, the comparison conflates the scoring criterion with the training intervention: VIG uses token-level loss masking, whereas ViCoR uses supervision calibration and diversity-aware reranking. Therefore, the observed differences cannot yet be attributed specifically to the first-order gradient residual. The explanations regarding broader generalization and compositional pathology signals are also speculative without further analysis.
Ultimately, VIG is a highly relevant and important prior work. The paper must provide a detailed discussion of its relationship to and differences from VIG, rather than leaving this comparison only in the rebuttal. Since NeurIPS does not allow manuscript revisions during the rebuttal period, there is currently no way to ensure that this essential discussion will be incorporated into the paper. This remains a significant concern in my evaluation.
Thank you for the response and clarification. We agree that VIG is highly relevant and will include a detailed comparison and discussion in the revised manuscript.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes ViCoR, an offline data selection method for fine-tuning medical VLMs. The method scores examples by comparing gradients from the original image-question pair with gradients from a mean-image shortcut condition, using the residual as a proxy for visual necessity. The score is further adjusted with supervision-quality features and diversity-aware reranking before selecting a 20% fine-tuning subset. Experiments across two backbones and several medical benchmarks show that ViCoR often outperforms full-data fine-tuning and existing selection baselines, with additional perturbation analyses suggesting stronger image dependence.
Strengths and weaknesses
[Strengths]
S1. Comparing original-image gradients with shortcut-image gradients is a reasonable and interpretable way to identify samples whose learning signal depends on visual content.
S2. The experiments are solid. The evaluation includes two backbones, multiple training sources, external benchmarks, multi-disease robustness, ablations, and perturbation audits.
S3. The gradient statistics and region-masking results provide more support than accuracy tables alone, even if they do not fully prove causal visual grounding.
[Weaknesses]
W1. Novelty is somewhat limited. ViCoR combines gradient-based selection, counterfactual input replacement, supervision filtering, and diversity reranking. The residual score is useful, but the paper should more clearly separate what is technically new from what is adapted from existing data selection and debiasing ideas.
W2. A large residual under mean-image replacement can indicate image dependence, but it may also reflect OOD shortcut inputs, uncertainty, or general sample difficulty. The paper acknowledges this partly, but some claims still read stronger than the evidence supports.
W3. All experiments are in medical VLM fine-tuning with two 4B-scale backbones and structured medical datasets. It is not clear whether the method would transfer to larger models, less structured datasets.
Questions
Q1. What does ViCoR add beyond simpler image-removal or residual-based selection heuristics? For example, how does the full score compare to selecting samples only by the original-vs-shortcut gradient residual, image-perturbation loss gap, or another direct image-dependence score? This would help clarify whether the contribution is the full pipeline or mainly the counterfactual residual signal.
Q2. How well does the proposed visual-necessity score correspond to independent evidence of visual grounding? A correlation with lesion boxes, evidence-region annotations, expert-rated visual subtlety, or image-only diagnostic difficulty would make the interpretation of the residual score more convincing.
Q3. Does the evidence-region masking result hold beyond the shared-correct GEMeX subset? The current audit is useful, but it would be stronger to know whether the same pattern appears on all originally correct examples per model, on failure cases, or on another dataset with localization annotations.
Limitations
yes
Final justification
The softening of causal claims in W2 and the honest acknowledgment of transfer limitations in W3 are appreciated. However, Q1 remains only partially addressed. The rebuttal restates the motivation for the full pipeline but does not provide the direct comparison with simpler residual-only selection that would isolate the marginal value of each component beyond the ablation already in the paper. The grounding evidence cited for Q2 is reasonable but drawn from the same analyses already present, rather than new validation. Overall a fair response, but the core question of how much the full pipeline adds over the counterfactual residual alone is not fully resolved. I maintain my score.
Formatting concerns
n/a
3 comments
Thank you for the constructive comments and positive feedback. We provide the following clarifications.
W1&Q1. Research significance and novelty. ViCoR reframes medical VLM selection around modality competition: it selects samples by non-redundant visual contribution to prevent text-easy supervision from starving visual learning. The technical novelty is the counterfactual residual in trainable parameter space. Proxy comparisons and ablations support the full design.
W2. Counterfactual-input robustness and interpretation. Appendix E replaces the mean image with blank, shuffled, and wrong images. Stable rankings show the result is not tied to one control. This cannot eliminate all shift or prove causality. We will therefore call ViCoR an optimization-level proxy for conditional image contribution and soften stronger claims.
W3. Independent grounding evidence. This is the role of our mechanism analyses, which we will signpost more clearly. Before fine-tuning, Table 9 compares ViCoR with an independently constructed no image and wrong image loss target and gives the best AUC/Precision@20%. Table 11 uses evidence-box annotations and finds the highest retention of small, peripheral, and hard evidence. Figure 3 then masks annotated evidence against matched background, yielding a 9.4-point gap with 95% CI [3.2, 9.6]. These behavioral and annotation-linked tests support correspondence with visual grounding.
Q2. Beyond the shared-correct subset. We used the same 362 initially correct cases to keep case composition identical across methods. All-correct examples per model would increase coverage but use different case sets, while failure cases require probability-shift rather than accuracy-drop analysis. We have not tested another localization-annotated dataset and will evaluate these extensions in future work.
Q3. Transfer. The residual equations require only gradients over the fine-tuned parameters and therefore apply to larger VLMs. The medical calibration can be adapted or replaced for less structured domains. Consistency across two backbones, three training sources, and configuration/control perturbations makes larger-scale transfer plausible, but does not prove it. Because of review-time and compute constraints, we did not test larger models. We will test these settings in future work.
I thank the authors for the thoughtful response. The softening of causal claims in W2 and the honest acknowledgment of transfer limitations in W3 are appreciated. However, Q1 remains only partially addressed. The rebuttal restates the motivation for the full pipeline but does not provide the direct comparison with simpler residual-only selection that would isolate the marginal value of each component beyond the ablation already in the paper. The grounding evidence cited for Q2 is reasonable but drawn from the same analyses already present, rather than new validation. Overall a fair response, but the core question of how much the full pipeline adds over the counterfactual residual alone is not fully resolved. I maintain my score.
Thank you for the follow-up. We agree that our previous response did not present the direct residual-only comparison clearly enough for Q1, while our response to Q2 relied only on analyses already included in the paper. We provide the two direct results below.
Q1. Full ViCoR versus residual-only selection. Appendix F, Table 8 reports this controlled comparison using Qwen3-VL-4B, GEMeX-ThinkVG, the same 20% budget, and the same fine-tuning recipe. “Residual Norm only” ranks samples solely by the magnitude of the counterfactual residual, without shortcut weighting, directional correction, thresholding, supervision calibration, or diversity-aware reranking.
| Selector | OMVQA | GMAI | MBLK | DRVD | Avg. | Multi-disease Acc. | Multi-disease Macro-F1 |
|---|---|---|---|---|---|---|---|
| Residual Norm only | 82.35 | 41.96 | 60.25 | 59.01 | 60.89 | 44.92 | 44.82 |
| Full ViCoR | 85.16 | 51.56 | 63.68 | 61.49 | 65.47 | 46.84 | 46.65 |
| Gain | +2.81 | +9.60 | +3.43 | +2.48 | +4.58 | +1.92 | +1.83 |
Thus, the full pipeline improves over residual-only selection on every external benchmark, increasing the four-benchmark average by 4.58 points and multi-disease Accuracy/Macro-F1 by 1.92/1.83 points. Table 8 shows that neither proxy signals nor the reduced pipeline recover the full benefit of ViCoR.
Q2. Correspondence with independent visual-dependence evidence. We evaluated an additional 1,200 GEMeX samples, separate from the 1,000 examples used in the original evidence-region audit. A positive behavioral response means that replacing the original image with a control increases the supervised rationale+answer loss. Because ViCoR selects the highest-ranked samples under a fixed budget, we compare the highest and lowest 20% by S_vis, matching the main selection budget.
| Held-out validation | Lowest 20% | Highest 20% | Difference [95% CI] |
|---|---|---|---|
| Mean-image control, sample level | 42.1% | 65.4% | +23.3 pp [14.6, 32.1] |
| Blank-image control, sample level | 51.7% | 75.8% | +24.2 pp [15.8, 32.5] |
| Mean-image control, image level | 40.0% | 63.6% | +23.6 pp [14.7, 32.4] |
Samples in the highest S_vis group are therefore 23–24 percentage points more likely to exhibit increased supervision loss after sample-specific visual information is removed. The same separation holds under an alternative control and after aggregating repeated questions at the image level, providing direct held-out evidence that S_vis enriches for behaviorally visual-dependent examples.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper tackles an important issue in VLMs, particularly for medical applications, which is subgroup failure. This can happen for a variety of reasons, including rare disease, uncommon presentation of common disease, and so on. In these cases, models may make short-cuts using textual priors. In this paper, the authors suggest using data selection methods to help adjust this learning signal. To help encourage visually grounded medical reasoning, the authors developed ViCoR, which uses a counterfactual-residual-based data selection method. They report an improvement in VLM performance across 2 different backbones using ViCoR-selected subsets (20%) for fine tuning.
Strengths and weaknesses
Strengths: Strengths include a novel methodology for data selection, using two different backbones, multiple external datasets, and ablation studies.
Weaknesses: -Concerning that random does better than 100% of the data. For example, on Qwen3-VL-4B backbone CXR-CounterFA=act-Single, random does better than 100% of the data. Also seen in the Table 12 with the 95% CI -- Full and Random have overlap. -Figure 4 makes it appear that other methods are having an increase in accuracy with higher selection ratio, but ViCoR drops at 40% (which is the highest number shown). Is it possible that other methods begin to win at 50%? This should be investigated. -While overall accuracy increases with this method, is it possible that performance gets worse on particular subsets of the data? The paper's central claim is about preventing subgroup failure, but it provides no subgroup-resolved or worst-group results.
Questions
-Consider also adding "Mirage: The Illusion of Visual Understanding" in the references. This may have come out after the submission but is relevant to the background of focusing too much on text. -While imaging ranking was pretty similar under alternative shortcut controls (Table 7), given that the performance was pretty close across different methods, it would be useful to know if these alternative shortcut controls actually impact performance.
Limitations
Yes.
Formatting concerns
None
1 comment
Thank you for the constructive comments and positive feedback. We provide the following clarifications.
W1. Random versus Full. This reversal occurs only for Qwen3-VL-4B/CXR-Single: Random 62.07 versus Full 61.63 (+0.44), with overlapping bootstrap CIs. Random is below Full in the other five settings, while ViCoR reaches 65.29 here. We therefore treat it as a close exception, not evidence that Random generally outperforms Full. It does not indicate an experimental failure, since all methods use the same training and evaluation configuration.
W2. 50% budget. We used 5%, 10%, 20%, and 40% as a conventional sweep to test robustness and the efficiency/performance tradeoff. At the added 50% point: Random 61.80, GraNd 62.98, LESS 62.59, Self-Filter 62.62, Adapt-∞ 61.92, and ViCoR 63.65. ViCoR remains highest by 0.67. It leads at 20%, 40%, and 50%, making 20% the smallest leading tested budget and our most data-efficient choice.
W3. Subgroups and worst-group performance. Thank you for raising this point. Preventing subgroup failure is the central goal of this work, so we demonstrate it using the better subset selected by ViCoR. Correspondingly, the unselected subset is the poorer-performing subset, so we did not discuss it separately.
Q1. MIRAGE. Thank you for pointing us to MIRAGE: The Illusion of Visual Understanding. Its analysis of apparently correct answers without genuine visual use is relevant to our motivation. We will add a discussion of this work.
Q2. Alternative shortcut controls. The purpose of this experiment may have been misunderstood. It is a robustness test showing that different treatments of the region containing pathological evidence do not change ViCoR’s ranking or conclusion. Across these treatments, the conclusion remains the same: once the model cannot access the key pathological region, performance declines. We will clarify this purpose.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 4/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes a counterfactual-residual-based data selection method for fine tuning medical vision-language models. Their approach estimates visual necessity by isolating the gradient component induced by sample-specific visual evidence. Their method is evaluated on two backbones, four external generalization benchmarks, and one multi-disease robustness benchmark.
Strengths and weaknesses
1. Quality
The paper is well written and structured, and easy to follow, with a particularly strong introduction and related work section that situates the contribution effectively. The paper presents intuitive explanations of the proposed method, particularly around Eq. (3), and supports these with well-motivated experimental sections, including a clearly reasoned ablation study (Section 4.5). These elements contribute to the perception that the methods have been carefully constructed.
However, there are several concerns that weaken the confidence in the robustness of the claims. First, the evaluation lacks reporting of standard deviations alongside mean results (Table 1), making it difficult to assess statistical significance and the reliability of observed improvements. Second, as specified in lines 202-208 the different evaluation benchmarks test different capabilities. I believe reporting the average across the four external benchmarks is misleading. Besides reporting per evaluation benchmark, I could suggest reporting per capability, for example, VQA (OmniMedVQA), perception (MedBLINK) or reasoning (GMAI-MMBench, DrVD-Bench). Third, in Section 4.6 on data efficiency, the choice of a 20% budget, where the proposed method performs best compared to alternatives, appears somewhat selective, as competing methods outperform it in lower budget regimes such as 5 to 10 percent. This raises the concern whether the evaluation fully reflects the method's comparative strengths.
Furthermore, the authors lack an explicit discussion of the limitations of their work, and the code is not publicly available. These issues raise concerns regarding transparency and reproducibility.
2. Clarity
As I already mentioned, the paper is well written and structured. Besides intuitive explanations of their proposed method, Figures 1 and 2 are particularly helpful in illustrating the motivation and workflow of the proposed method.
Aggregating metrics across diverse benchmarks may obscure interpretation of the results. As suggested, a more granular breakdown, for example by capability (such as perception, reasoning, or VQA) would better inform readers.
3. Significance
This paper addresses an important problem, as both data scarcity and shortcut learning are key challenges in medical imaging, making it highly relevant for researchers and practitioners working with large-scale multimodal or medical datasets.
However, the current evaluation limits the strength of the conclusions, as noted in the Quality section. In addition, it would be helpful to more clearly articulate how the proposed method differs from CXR-CounterFact [33], which appears to be the most closely related work.
4. Clarity
The paper is generally well written, well structured, and easy to follow. Although, several aspects would benefit from further clarification.
First, it is not clear why different experiments are conducted on different datasets—for example, the rationale behind evaluating evidence-region perturbation on GEMeX is not explicitly motivated.
Second, some methodological descriptions are ambiguous. In Section 4.3 (Fine-Grained Finding-Combination Analysis), the notion of “near-miss win rate” is not sufficiently defined, particularly how distractors are introduced. Similarly, Section 4.4 (Gradient-Level Selection Analysis) raises interpretability concerns: the results in Table 4 seem expected, as the proposed method is explicitly designed for gradient-based selection, while competing methods are not. This makes it unclear how informative this comparison is in evaluating the effectiveness of the method.
Third, some terms would benefit from clarifications. The phrase “ViCoR-selected 20% subsets,” used in the abstract and introduction, is not immediately clear, as the acronym is defined only later and the meaning of the 20% subsets is not explained. In Figure 1, the concept of “global normality cues” would benefit from clarification. In Figure 2, the statement “same final answer yi” is also confusing, as it is not clear how the method ensures identical outputs when the joint and shortcut inputs differ, and this assumption requires further justification.
References
[33] Yang, X., Lu, J., & Yu, E. (2026). Walking the tightrope: Autonomous disentangling beneficial and detrimental drifts in non-stationary custom-tuning. Advances in Neural Information Processing Systems, 38, 116167-116193.
Questions
- Could the authors clarify how their approach differs from CXR-CounterFact [33], which appears closely related, and explain why this method is not included as a baseline in the experimental comparisons?
- Would it be more informative to report performance averaged per capability across benchmarks, rather than relying on a single overall average?
- Do the benchmarks used in this work provide any measure or indication of how important the image modality is for the final classification or diagnosis? In particular, are there annotations or subsets that distinguish between image-dependent and text-dependent cases?
- Since the proposed calibration relies on visual uncertainty, are all diseases or cases in the evaluated benchmarks reliably diagnosable from images alone? How does the method perform in scenarios where both image and textual information are required?
- As a suggestion, the authors might be interested in a related work https://arxiv.org/abs/2509.18234v3, which include multiple-choice questions where some can be answered without images.
Limitations
yes, section K in Appendix
Final justification
The authors provide some helpful clarifications regarding the distinction between their method and CXR-CounterFact, as well as additional capability-level results that help contextualize their contributions.
However, I remain concerned about the role of the image modality. It is still unclear to what extent the benchmarks require visual information and how this limitation affects the validation of the proposed method.
Therefore, I will keep my score unchanged.
Formatting concerns
no
1 comment
We sincerely thank you for the careful review and positive feedback on our work. We agree that several implementation and validation details should be stated more explicitly.
Q1&W3. CXR-CounterFact [33]. Counterfactual Preference Optimization (CPO) [33] uses generated counterfactual trajectories to separate beneficial from harmful drift in non-stationary preference tuning. ViCoR instead ranks a fixed pool through original-versus-mean-image gradients. CPO modifies tuning to manage drift, whereas ViCoR selects K examples for unchanged SFT and uses CXR-CounterFact only as training data. They are different method classes. Thus CPO is not a like-for-like fixed-budget baseline.
Q2&W2. Capability-level reporting. We acknowledge that averaging across the four benchmarks may obscure performance on individual capabilities. In the previous submission, we reported the mean value due to page constraints. Under the same fine-tuning protocol and a 20% selection budget, we report Qwen3-VL-4B results using GEMeX-ThinkVG as the training pool on two representative benchmarks: OmniMedVQA for medical VQA and DrVD-Bench for visual diagnostic reasoning. Representative original benchmark dimensions are shown below, and we will add the full results to the appendix.
| OmniMedVQA (VQA) | ViCoR | Best fixed baseline | Δ |
|---|---|---|---|
| Modality / Fundus Photography | 86.88 | LESS 85.63 | +1.25 |
| Modality / Ultrasound | 83.93 | Adapt-∞ 81.50 | +2.43 |
| Question type / Anatomy Identification | 83.49 | GraNd 81.41 | +2.08 |
| Question type / Other Biological Attributes | 86.34 | LESS 83.81 | +2.53 |
| DrVD-Bench (reasoning) | ViCoR | Best fixed baseline | Δ |
|---|---|---|---|
| Task / View Recognition | 63.34 | GraNd 61.33 | +2.01 |
| Task / Noise Recognition | 60.05 | LESS 59.33 | +0.72 |
| Modality / Radiograph | 61.13 | Full 59.78 | +1.35 |
| Modality / CT | 61.44 | Full 60.64 | +0.80 |
Q3. Image/text dependence and GEMeX. The external benchmarks lack item-level labels declaring whether a question is image- or text-dependent. We assess this indirectly by comparing intact-image performance with no-image and wrong-image inputs: with text fixed, the intact-image gain indicates visual reliance. GEMeX is used for region masking because its evidence-box annotations enable controlled analysis and visualization of dependence on clinically relevant regions.
Q4. Cases requiring both modalities. We do not assume that every case is diagnosable from the image alone, and the calibration does not rely on visual uncertainty. The benchmarks do not label a separate joint-required subset. However, all training and evaluation use joint image-text inputs. In medical tasks, text provides context, while subtle image findings often carry diagnostic evidence beyond superficial textual cues. ViCoR preserves this visual contribution when both modalities are needed rather than discounting text.
W1. Budget choice. We used 5%, 10%, 20%, and 40% as a conventional sweep to test robustness and the efficiency/performance tradeoff. At the added 50% point: Random 61.80, GraNd 62.98, LESS 62.59, Self-Filter 62.62, Adapt-∞ 61.92, and ViCoR 63.65. ViCoR remains highest by 0.67. It leads at 20%, 40%, and 50%, making 20% the smallest leading tested budget and our most data-efficient choice.
W4. Protocol and terminology. NM-Win adds no synthetic distractor: it compares the correct CheXbench option with the most clinically similar benchmark-provided incorrect option. We will frame Table 4 as a sanity check in ViCoR’s gradient space. We will define “ViCoR-selected 20%” as the final K=0.2N examples, explain “global normality cues” as diffuse image statistics/normal-class priors without lesion localization, and replace Fig. 2’s “same final answer” with “same supervised target.”
Related work, uncertainty, limitations, and code. The Illusion of Readiness in Health AI reinforces our motivation to distinguish genuine visual-evidence use from textual shortcuts. We will add a discussion of this work. Appendix I reports benchmark-stratified bootstrap 95% CIs and paired intervals: four of six comparisons are clearly positive, while the two closest include zero. Full three-seed SDs were omitted from the main text due to space and will be added to the revised appendix. Appendix K discusses ViCoR’s limitations, including proxy and control assumptions, annotation coverage, computational scaling, and clinical deployment. To improve transparency and reproducibility, we will publicly release our scoring, selection, and training code with the corresponding configurations.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Thank you for pointing us to this relevant work, which was published after we had begun our work and had therefore escaped our attention. We now provide additional theoretical analysis and an empirical comparison.
Theoretical comparison. Both VIG and ViCoR are data-centric approaches to VLM training. Both compare the original image with a degraded or controlled visual input to estimate the contribution of vision beyond textual cues, prioritize visually dependent supervision under a fixed data budget, and reduce language-shortcut learning without changing the model architecture. However, they differ in their estimands and training interventions. VIG is a zeroth-order prediction signal based on the answer-token loss or perplexity reduction from a blurred image to the original image. It ranks samples and masks the training loss to high-VIG answer tokens. ViCoR is a first-order optimization signal based on the residual between original-image and mean-image-control gradients in the trainable parameter space. It further models shortcut pressure and residual direction, calibrates medical supervision, and reranks for diversity while leaving the subsequent SFT objective unchanged. We will add this distinction to the revised discussion.
Empirical comparison.
Under the comparison setting, both methods use Qwen3-VL-4B as the backbone, GEMeX-ThinkVG as the training pool, a 20% data budget, and the same fine-tuning recipe. Results are reported on the same benchmark suite.
These results show complementary strengths rather than uniform dominance. ViCoR is stronger on three of four external benchmarks and the overall average, suggesting that its gradient-level residual and diversity-aware selection favor broader cross-benchmark generalization. VIG is stronger on GMAI-MMBench and the multi-disease evaluation, suggesting that its token-level information-gain objective may better preserve some reasoning-intensive or compositional pathology signals. The two methods capture different aspects of visual dependence, and their relative advantages vary across evaluated capabilities.