Rethinking CT Synthesis through Semantics-Structure Alignment
Riyu Qiu, Qichao Zhou, jiacheng wang, Liansheng Wang
Abstract. Mask-guided CT synthesis bridges structural annotations with imaging appearance, facilitating data augmentation and clinical tasks such as radiotherapy planning. Despite plausible visual realism, current methods seek optimal solutions by treating all tissues uniformly, failing to capture intrinsic CT properties such as tissue-specific distributions and strict anatomy, leading to semantic misalignment and structural hallucinations. To address this, we decompose CT synthesis into semantics-structure alignment through the proposed Semantics and Structure Loss. Specifically, the Semantic Intensity Distribution (SID) Loss partitions the broad Hounsfield Unit (HU) range into semantic subspaces to achieve tissue-specific intensity alignment. Building on SID-based semantic alignment, the Structural Anatomy (SA) Loss further improves structural fidelity by regularizing gradient manifolds within clinically-informed spatial domains. Extensive experiments across GAN, Diffusion, flow, and foundation models demonstrate the broad compatibility and consistent gains of our approach. A user study further confirms the clinical realism and mask fidelity, while downstream segmentation demonstrates the practical utility. Code is available at https://github.com/16rq/Semantics-and-Structure-Loss-for-CT-synthesis.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:43 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
Needs clarification during the response period
The paper proposes two CT-specific training losses for mask-guided CT synthesis: a Semantic Intensity Distribution (SID) loss that matches per-region Hounsfield-unit distributions via a Wasserstein-1 distance, and a Structural Anatomy (SA) loss that matches smoothed gradient maps. The losses are generator-agnostic and are tested across GAN, diffusion, flow, and a 3D foundation model on SegRap and AutoPET, with image-quality metrics, a user study, and a downstream segmentation experiment.
The problem is well-motivated (perceptual realism does not guarantee correct HU distributions) and the breadth across backbones is a genuine strength. The reviews are split (one reject, one borderline reject, one borderline accept), and I do not yet see a reason to reject. The concerns below are the ones that will decide the outcome; each must be addressed to my and the reviewers' satisfaction. Concerns I have not listed need not be the focus of the response.
Major concerns
-
The "causal" frequency argument (Section 3.3) is unsound as stated. All three reviewers flag it as overclaimed: there is no causal intervention or identification, so it is at most a frequency-domain interpretation. The problem runs deeper than terminology. As Reviewer 4Kg1 notes, the SID loss "compares the marginal distributions of HU values within each anatomical mask and is invariant to spatial permutations within that mask", so it carries no spatial-frequency information and cannot "anchor low-frequency components." The sinc/convolution argument in 3.3.1 concerns the spectrum of the mask indicator, not the quantity the SID loss actually constrains, so the low-frequency-anchoring claim does not follow. Drop "causal," present the spectral improvement as an empirical observation, and either prove or remove the low-frequency claim.
-
The headline downstream result (synthetic real) is confounded, and the metrics are internally inconsistent (Table 2). Training a segmenter on LDM-synthesized data outperforms training on real data, which all three reviewers flag as counterintuitive. Because the synthetic CTs are generated from the same masks that serve as the segmentation targets, this is what mask-consistency leakage would produce (the synthetic set is more label-consistent than noisy real data) rather than evidence of genuine utility. In a leakage-free comparison a synthetic-only model should not exceed real-only training on a real, disjoint test set. Separately, the reported IoU is inconsistent with the reported Dice (Reviewer mcfo): by the identity , the per-class Dice–IoU gaps for SpinalCord (Dice 0.55) and Brain (Dice 0.71) alone sum to more than the total gap the reported means permit across all 45 organ classes (mean Dice 0.910 vs mean IoU 0.906, a gap of 0.004), so the two cannot both hold under a consistent averaging convention. Please give the full protocol (what is trained on synthetic versus real, equal data sizes, whether masks are shared, whether the test set is fully real and disjoint, and leakage controls), reconcile the metrics, and reinterpret the claim.
-
The evaluation is under-specified and under-powered. Reviewer 4Kg1 (major) notes there are no train/validation/test split counts, no statement of patient- versus slice-level splitting, and no patient-level variability or confidence intervals (Checklist #6–#7), all of which are critical here. The user study lacks reader count, expertise, blinding, randomization, and inter-rater agreement (FjxJ, 4Kg1). Evaluation is 2D slice-based on volumetric data; 3D metrics are requested and, being evaluation-only, are cheap to add (4Kg1). These are needed before the quantitative claims can be assessed.
-
Integration across generator families, and conditional diversity, are not established. Reviewer mcfo raises two points I share. First, applying image-space HU and gradient losses inside diffusion and flow training requires a clean-image estimate at every step, which is unreliable early in diffusion, and, for latent diffusion, interacts with VAE decoding (is the VAE frozen; does the SID loss penalize VAE reconstruction error?). These details belong in the main text. Second, mask-guided synthesis is one-to-many, but the losses supervise against the single paired real CT, which may collapse conditional diversity; show multiple samples per mask and analyze whether diversity is preserved. Robustness to noisy or coarse masks (FjxJ) belongs here as well.
-
Clarity of exposition and results presentation. All three reviewers rate clarity "not good," and it materially impedes assessment. Section 3.3 is the main offender: the frequency-domain derivation moves between the mask spectrum, the Sobel response, and the two losses without making explicit which object each equation constrains, which is part of why the "causal" claim reads as overstated (Major 1); it should be rewritten to state plainly what is and is not shown. The empirical section is also hard to read: the central comparison is carried by dense tables (Table 1 alone spans five metrics across two datasets and roughly a dozen methods) and by prose that recites values rather than interpreting them, so the main finding — where the combined LS² loss helps, and across which backbones and metrics — is difficult to extract. A figure showing the per-method, per-metric improvement would convey this far more directly than the current tables and should be foregrounded. Relatedly, several important method details (the diffusion/flow/VAE integration of Major 4) currently appear only in the appendix and should be in the main text (mcfo).
Minor concerns
- "Spectral bias and F-Principle" (l. 81) are invoked without references or explanation.
- The SID loss weights every clinical window and anatomical region equally (uniform over windows and over organ masks), so a small critical structure counts the same as a large one; motivate or reconsider this weighting.
Concerns I have not listed need not be the focus of the response.
Final justification
I have read the authors' rebuttal and the full reviewer discussion. The response substantively addressed the concerns in my initial meta-review, and all three reviewers raised their scores over the exchange (mcfo 2→4, FjxJ 4→5, 4Kg1 3→5), converging on a unanimous accept-leaning panel.
Against the five major concerns:
- Causal / frequency argument (Major 1): the "causal" claim is retracted and reframed as empirical, with the SID-vs-histogram-loss spectral validation added. Resolved.
- Downstream synthetic-vs-real and Dice/IoU (Major 2): protocol specified and the "synthetic beats real" claim tempered to a hypothesis; my Dice/IoU objection does not hold under their macro-averaging (mcfo agreed). Resolved.
- Evaluation rigor (Major 3): splits, patient-level 3D metrics, single-reader study details (suitably tempered), and 3D / multiplanar metrics added. Resolved.
- Integration and diversity (Major 4): full LDM objective, a timestep-stability analysis, a scoped flow derivation, and an honest diversity analysis added. Resolved.
- Clarity / presentation (Major 5): the specific gaps were filled in discussion; mcfo still flags the submitted paper's presentation as the residual, contingent on the camera-ready folding in the promised additions.
Read meta-review
Meta-review
Needs clarification during the response period
The paper proposes two CT-specific training losses for mask-guided CT synthesis: a Semantic Intensity Distribution (SID) loss that matches per-region Hounsfield-unit distributions via a Wasserstein-1 distance, and a Structural Anatomy (SA) loss that matches smoothed gradient maps. The losses are generator-agnostic and are tested across GAN, diffusion, flow, and a 3D foundation model on SegRap and AutoPET, with image-quality metrics, a user study, and a downstream segmentation experiment.
The problem is well-motivated (perceptual realism does not guarantee correct HU distributions) and the breadth across backbones is a genuine strength. The reviews are split (one reject, one borderline reject, one borderline accept), and I do not yet see a reason to reject. The concerns below are the ones that will decide the outcome; each must be addressed to my and the reviewers' satisfaction. Concerns I have not listed need not be the focus of the response.
Major concerns
-
The "causal" frequency argument (Section 3.3) is unsound as stated. All three reviewers flag it as overclaimed: there is no causal intervention or identification, so it is at most a frequency-domain interpretation. The problem runs deeper than terminology. As Reviewer 4Kg1 notes, the SID loss "compares the marginal distributions of HU values within each anatomical mask and is invariant to spatial permutations within that mask", so it carries no spatial-frequency information and cannot "anchor low-frequency components." The sinc/convolution argument in 3.3.1 concerns the spectrum of the mask indicator, not the quantity the SID loss actually constrains, so the low-frequency-anchoring claim does not follow. Drop "causal," present the spectral improvement as an empirical observation, and either prove or remove the low-frequency claim.
-
The headline downstream result (synthetic real) is confounded, and the metrics are internally inconsistent (Table 2). Training a segmenter on LDM-synthesized data outperforms training on real data, which all three reviewers flag as counterintuitive. Because the synthetic CTs are generated from the same masks that serve as the segmentation targets, this is what mask-consistency leakage would produce (the synthetic set is more label-consistent than noisy real data) rather than evidence of genuine utility. In a leakage-free comparison a synthetic-only model should not exceed real-only training on a real, disjoint test set. Separately, the reported IoU is inconsistent with the reported Dice (Reviewer mcfo): by the identity , the per-class Dice–IoU gaps for SpinalCord (Dice 0.55) and Brain (Dice 0.71) alone sum to more than the total gap the reported means permit across all 45 organ classes (mean Dice 0.910 vs mean IoU 0.906, a gap of 0.004), so the two cannot both hold under a consistent averaging convention. Please give the full protocol (what is trained on synthetic versus real, equal data sizes, whether masks are shared, whether the test set is fully real and disjoint, and leakage controls), reconcile the metrics, and reinterpret the claim.
-
The evaluation is under-specified and under-powered. Reviewer 4Kg1 (major) notes there are no train/validation/test split counts, no statement of patient- versus slice-level splitting, and no patient-level variability or confidence intervals (Checklist #6–#7), all of which are critical here. The user study lacks reader count, expertise, blinding, randomization, and inter-rater agreement (FjxJ, 4Kg1). Evaluation is 2D slice-based on volumetric data; 3D metrics are requested and, being evaluation-only, are cheap to add (4Kg1). These are needed before the quantitative claims can be assessed.
-
Integration across generator families, and conditional diversity, are not established. Reviewer mcfo raises two points I share. First, applying image-space HU and gradient losses inside diffusion and flow training requires a clean-image estimate at every step, which is unreliable early in diffusion, and, for latent diffusion, interacts with VAE decoding (is the VAE frozen; does the SID loss penalize VAE reconstruction error?). These details belong in the main text. Second, mask-guided synthesis is one-to-many, but the losses supervise against the single paired real CT, which may collapse conditional diversity; show multiple samples per mask and analyze whether diversity is preserved. Robustness to noisy or coarse masks (FjxJ) belongs here as well.
-
Clarity of exposition and results presentation. All three reviewers rate clarity "not good," and it materially impedes assessment. Section 3.3 is the main offender: the frequency-domain derivation moves between the mask spectrum, the Sobel response, and the two losses without making explicit which object each equation constrains, which is part of why the "causal" claim reads as overstated (Major 1); it should be rewritten to state plainly what is and is not shown. The empirical section is also hard to read: the central comparison is carried by dense tables (Table 1 alone spans five metrics across two datasets and roughly a dozen methods) and by prose that recites values rather than interpreting them, so the main finding — where the combined LS² loss helps, and across which backbones and metrics — is difficult to extract. A figure showing the per-method, per-metric improvement would convey this far more directly than the current tables and should be foregrounded. Relatedly, several important method details (the diffusion/flow/VAE integration of Major 4) currently appear only in the appendix and should be in the main text (mcfo).
Minor concerns
- "Spectral bias and F-Principle" (l. 81) are invoked without references or explanation.
- The SID loss weights every clinical window and anatomical region equally (uniform over windows and over organ masks), so a small critical structure counts the same as a large one; motivate or reconsider this weighting.
Concerns I have not listed need not be the focus of the response.
Final justification
I have read the authors' rebuttal and the full reviewer discussion. The response substantively addressed the concerns in my initial meta-review, and all three reviewers raised their scores over the exchange (mcfo 2→4, FjxJ 4→5, 4Kg1 3→5), converging on a unanimous accept-leaning panel.
Against the five major concerns:
- Causal / frequency argument (Major 1): the "causal" claim is retracted and reframed as empirical, with the SID-vs-histogram-loss spectral validation added. Resolved.
- Downstream synthetic-vs-real and Dice/IoU (Major 2): protocol specified and the "synthetic beats real" claim tempered to a hypothesis; my Dice/IoU objection does not hold under their macro-averaging (mcfo agreed). Resolved.
- Evaluation rigor (Major 3): splits, patient-level 3D metrics, single-reader study details (suitably tempered), and 3D / multiplanar metrics added. Resolved.
- Integration and diversity (Major 4): full LDM objective, a timestep-stability analysis, a scoped flow derivation, and an honest diversity analysis added. Resolved.
- Clarity / presentation (Major 5): the specific gaps were filled in discussion; mcfo still flags the submitted paper's presentation as the residual, contingent on the camera-ready folding in the promised additions.
6 comments
Response to Major concern2 in meta review: segmentation protocol and results interpretation
We will clarify the downstream segmentation protocol, discuss why synthetic-only training may outperform real-only training, and clarify Dice-IoU relationship.
Segmentation experiments used the same patient-wise split as synthesis (90/20/10 for train/val/test on SegRap), with no patient overlap. All segmentation models were trained and validated solely on synthetic CTs paired with real masks. The same patients, masks, and sample sizes were used across all segmentation experiments. Evaluation was conducted exclusively on real CTs and real masks from unseen test patients. Therefore, this is a synthetic-to-real evaluation rather than a real-data augmentation setting.
Why synthetic-only outperformed real-only: (1) Synthetic CTs are more standardized, with less scanner noise, acting as regularization. (2) Real CTs and manual annotations may have boundary misalignment, while synthetic CTs provide more label-consistent training pairs. Importantly, we do not claim that synthetic data are superior to real data. LDM data generated with LS2 achieved better performance on the independent real test set, indicating improved synthetic-to-real transfer utility. Nevertheless, the experiment was conducted on only 10 test patients from the single-center SegRap dataset. The result should therefore be interpreted cautiously and larger multi-center studies are required for synthetic and real comparison.
As for Dice-IoU relationship, our averaging scheme is: Dice and IoU were first computed independently for each organ on each 2D slice. The slice-level values were then macro-averaged (weighted equally regardless of region size) within each organ, followed by macro-averaging across organs to obtain the reported mean Dice and mean IoU. The nonlinear Dice–IoU conversion () holds per sample, but not after macro-averaging: $$
For example, consider two slices with Dice of 1.0 and 0.1. Their mean Dice is 0.55. The corresponding IoU are 1.0 and 0.0526, giving a mean IoU of 0.5263. In contrast, converting the mean Dice directly via IoU-Dice relationship would yield 0.55/(2−0.55)=0.3793. In this case, the IoU-Dice relationship does not hold in the example you provided about "SpinalCord (Dice 0.55), Brain (Dice 0.71), mean Dice 0.910, and mean IoU 0.906".
Response to Major concern3 in meta review: experiment settings and reporting of variability in 2/3D results
We will specify data splits and setting of all experiments including reader study and add mean±std results based on 2D and 3D.
All experiments used a patient-wise data split with disjoint patient cohorts across training, validation, and test sets. AutoPET included 370/108/55 patients (69.5%/20.3%/10.3%), while SegRap included 90/20/10 patients (75.0%/16.7%/8.3%). The same patient-level splits were used for all generative models and downstream segmentation experiments.
As for reader study details, an associate consultant radiologist (13 years of experience) independently evaluated 100 randomly selected masks, each paired with real CT and synthetic CT (100 real pairs+100 synthetic pairs). All samples were mixed and presented in a randomized order. Each image-mask pair was stored separately, and all information indicating image origin was removed to ensure blinded evaluation. In evaluation, each pair was scored 0–2 for image realism and boundary consistency. Results are reported as counts and proportions of scores 0/1/2 per group. Since only one radiologist participated, inter-rater agreement was not assessed. We will acknowledge this as a limitation.
Additionally, we add mean±std results based on 2D and additionally provide patient-level 3D metrics, including 3D SSIM and 3D PSNR, to quantify inter-patient variability. FID, LFD, and HU-W1 remain evaluated at the slice level, as these metrics are inherently defined on 2D images or 2D image distributions. Due to space limitations, we only report the revised slice-level and 3D results for SegRap as follows in this turn.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper introduces a Semantics and Structure Loss for mask-guided CT generation. The SID loss aligns HU distributions for different organs and tissue-specific regions, while the SA loss regularizes anatomical structure using gradient-based constraints. The effectiveness of this loss is evaluated across different backbones. Specifically, the method is tested on SegRap and AutoPET using GAN, diffusion, flow, and 3D foundation-model backbones. On downstream segmentation task, the generated image can train models that outperform models trained on real data.
Strengths and weaknesses
Strengths:
-
The proposed loss is intuitive and well motivated. The SID loss targets tissue-specific HU distribution alignment, while the SA loss targets structural fidelity through anatomical gradients.
-
The paper also evaluates the loss across different generative backbones, including GAN, diffusion, flow, and a 3D foundation model, and the comparison is quite comprehensive, benchmarking the paper against rich competitors.
Weaknesses
-
My major concern is that the proposed loss may reduce conditional diversity. Mask-guided CT synthesis is naturally a one-to-many problem: the same mask can correspond to multiple plausible CT images. However, the proposed loss is computed between the generated CT and the corresponding real CT during training. This may push the model toward one specific target image for each input mask. This does not necessarily mean that the model will always generate the same image for a given condition, but the paper does not evaluate whether multi-sample diversity is preserved. The authors should show multiple generated samples from the same mask and analyze whether LS2 reduces variation.
-
The application of these image space loss functions are also limited. The paper claims that LS2 works with diffusion and flow models, but the integration details need more clarification. First, the flow formulation seems tied to a simple linear path or per-step clean-image estimate. Second, for latent space generative models, the author doesn't explain how the loss function interacts with the VAE. Third, in diffusion steps, the author estimated a clean image every step, which, at early stage of diffusion, can be really unreliable. Last, and least, the reviewer think the integration details should be put in the main text, not just in the appendix.
-
Another weakness is readability, especially in Section 3.3 and the experiment section. Section 3.3 gives a frequency-domain explanation for why semantic-structure modeling may improve spectral alignment. This is useful intuition, but it does not establish causality in the usual sense. There is no causal intervention or causal identification. The paper should probably call this a frequency-domain interpretation rather than a causal perspective.
The experiment section also misses some important details in the main text. For example, Table 2 shows that training with LDM-generated data gives better downstream segmentation performance than training with true data, and LDM+LS2 improves further. This is possible, but counterintuitive. The authors should clarify the exact downstream setup: whether the amount of training data is equal, whether synthetic and real data use the same masks, whether the test set is fully real and disjoint, and whether there is any risk of mask-to-image leakage.
Justification of my ratings below:
Quality: 2 Not good. The method is reasonable, but several important experimental details are missing or unclear.
Clarity: 2 Not good. The high-level idea is understandable, but Section 3.3 is hard to follow and uses “causal” too strongly. The experiment section also omits key setup details that are needed to interpret the results.
Significance: 2 Not good The problem is important, but the loss functions provided is limited to specific settings of flow matching and diffusion.
Originality: 3 Good. The paper does not propose a new generative model, but the CT-specific loss design is useful and reasonably original. The main contribution is the semantic intensity distribution loss and structural anatomy loss, and their application across different model families.
Questions
- Since LS2 compares the generated CT with the corresponding real CT, does it push the model toward a single target image for each mask? Some diversity or stochasticity analysis would be helpful.
- For latent diffusion models, is LS2 computed after VAE decoding? Since SID and SA depend on HU values and image gradients, computing them in latent space would be hard to interpret.
- Is the VAE frozen when applying LS2 to LDM? If the VAE is imperfect at reconstructing HU values, SID may penalize the diffusion model for VAE reconstruction errors.
- Section 3.3 is useful as a frequency-domain interpretation, but the term “causal” seems too strong. There is no actual causal intervention or causal identification.
- In Table 2, why does training on LDM-generated data outperform training on true data? This is possible, but counterintuitive and needs a clearer explanation. And details for these experiments are also essential. For example, are the real-data, LDM-data, and LDM+LS2-data training sets the same size? Additionally, the Dice and IoU values in Table 2 do not appear to follow the usual Dice-IoU relationship. This may be valid if different averaging schemes are used, but the paper should define this clearly.
- [Nit] How sensitive is SID to the choice of HU windows and organ masks?
Limitations
No. The paper does not include a dedicated limitations section. Several important limitations are not well discussed. For example, the computational cost of reconstructing a clean image estimate during diffusion or flow training, the interaction with latent diffusion/VAE decoding, and the practical application scenarios (latent diffusion, pixel-space diffusion) are not clearly addressed. The authors should discuss these limitations more explicitly.
Final justification
After considering the rebuttal and subsequent discussion, I have raised my score to 4.
I consider the work technically solid, although the presentation of the paper should be better enhanced to make sure on reproducibility.
Formatting concerns
No
8 comments
Rebuttal
Weakness1 and question1: multi-sample diversity under LS2
We will add diversity analysis in the revision.
On AutoPET test set, we sampled 10 times per mask across head, chest, and abdomen using LDM and LDM+LS2, and computed LPIPS (perceptual diversity), (1−SSIM) (structural diversity), and HU-W1 (HU distribution diversity). LDM+LS2 reduced LPIPS from 0.0506±0.0195 to 0.0353±0.0148 and (1−SSIM) from 0.1314±0.0436 to 0.0948±0.0284. This is consistent with design of LS2 since it would reduce unstable visual and structural variations.
However, diversity does not collapse. HU-W1 only decreased from 1.8949±0.5328 to 1.7671±0.3670, indicating intensity variations from random sampling are largely preserved. Visualizations confirm that unconstrained regions (e.g., muscle, soft tissue, boundary details) still vary reasonably. Since links for images are nor permitted here, figures will be in the revision.
Overall, LS2 constrains organ-level distributions, not pixel-wise reconstruction, so it does not collapse one-to-many to one-to-one. The experiments confirm LS2 filters unanatomical variations while preserving stochasticity, achieving a favorable fidelity–diversity trade-off.
Weakness2 and question2,3: integration details
Thank you for the detailed suggestions. We will add the integration details to the main text.
For LDM, LS2 is computed in image space. The VAE decoder is frozen; it decodes the latent code into an image, where LS2 is computed, and gradients pass through the decoder to the diffusion. VAE reconstruction is accurate (AutoPET: MAE 0.0039, SSIM 0.9824, PSNR 36.97; SegRap: 0.0028, 0.9893, 38.52). Although frozen VAE errors remain, the same VAE is used for baseline and LS2 and comparisons are fair. We will explicitly state that VAE reconstruction fidelity sets an upper bound for LS2 performance under LDM framework. In order to keep LS2 definition consistency and comparison fairness across all baselines, we do not apply time-step weighting to diffusion training. Despite this, LS2 still improves results obvisouly (Table 1). We leave it as future work.
For flow, LS2 applies the same way: any flow that outputs a differentiable clean-image prediction can compute SID and SA in image space. Equation (12) is specific to our MOTFM flow setup and is not a requirement for LS2. LS2 only needs an image-space prediction, regardless of the flow path. We will clarify this in the main text.
Weakness3 and question4: frequency-domain interpretation
We agree that "causal perspective" is inappropriate and will revise it. We will also add data analysis and spectral validation of frequency improvement to better support our claims in the revised manuscript.
Intuitively, compared with arbitrary image patches, patches within anatomical masks exhibit more concentrated HU distributions and lower spatial intensity variation in CT. In AutoPET, organ-mask patches show substantially lower intensity variation (std: 48.53 vs. 157.15; IQR: 46.09 vs. 159.50; median absolute deviation: 20.35 vs. 37.42) and smaller gradient magnitudes (mean gradient: 12.68 vs. 22.31; total variation: 24.87 vs. 35.97) compared to random patches. This provides empirical support for the link between organ-level distribution constraints and low-frequency consistency.
We clarify that our claim is not that SID theoretically guarantees low-frequency alignment for all images. Rather, the observed spectral improvements are an empirical byproduct of semantic-structural regularization on medical CT data, where organ-level intensity distributions are inherently constrained.
As for additional spectral validation, we compared SID with the differentiable histogram loss in [1] (suggested by reviewer 4Kg1), applied either globally or within organ masks under the same pix2pixHD settings in Table 1 of paper. The baseline low-frequency error (LF error) was 0.491±0.061. The global histogram loss reduced it to 0.480±0.062, whereas the organ-wise histogram loss further reduced it to 0.451±0.058. The high-frequency error (HF error) remained almost unchanged for the organ-wise histogram loss (0.416±0.042 vs. 0.418±0.043 for the baseline), while HU-W1 improved from 188.706±4.960 to 167.553±15.672.
Notably, SID produced a larger improvement compared to [1], reducing HU-W1 to 162.303±21.320 and LF error to 0.391±0.051, a reduction of approximately 20.4% from the baseline. Its HF error remained close to the baseline at 0.408±0.037, indicating that its main effect is organ-aware HU alignment accompanied by improved low-frequency spectral consistency, rather than uniform improvement across all frequency bands. In contrast, SA had little effect on the LF error but reduced the HF error to 0.295±0.013. Combining SID and SA, LS2 achieved LF and HF errors of 0.389±0.047 and 0.287±0.022, respectively, together with the best SSIM of 0.752±0.048 and the lowest HU-W1 of 159.242±4.668.
[1] M. Avi-Aharon, A. Arbelle, and T. Riklin Raviv, “Differentiable Histogram Loss Functions for Intensity-Based Image-to-Image Translation,” IEEE Transactions on Pattern Analysis and Machine Intelligence, vol. 45, no. 10, pp. 11642–11653, Oct. 2023, doi: 10.1109/TPAMI.2023.3278287.
Question5: downstream segmentation protocol and interpretation
We will add full segmentation details in the revision.
Segmentation experiments used the same patient-wise split as synthesis (90/20/10 for train/val/test on SegRap), with no patient overlap. All segmentation models were trained and validated solely on synthetic CTs paired with real masks. The same patients, masks, and sample sizes were used across all segmentation experiments. Evaluation was conducted exclusively on real CTs and real masks from unseen test patients—no leakage occurred. We acknowledge that using the same mask as generation condition and segmentation label increases image-label consistency, but this is not test-set leakage.
Why synthetic-only outperformed real-only: (1) Synthetic CTs are more standardized, with less scanner noise, acting as regularization. (2) Real CTs and manual annotations may have boundary misalignment, while synthetic CTs provide more label-consistent training pairs.
Importantly, we do not claim that synthetic data are superior to real data. LDM data generated with LS2 achieved better performance on the independent real test set, indicating improved synthetic-to-real transfer utility. Nevertheless, the experiment was conducted on only 10 test patients from the single-center SegRap dataset. The result should therefore be interpreted cautiously and larger multi-center studies are required for synthetic and real comparison.
As for Dice–IoU relationship, our averaging scheme is: Dice and IoU were first computed independently for each organ on each 2D slice. The slice-level values were then macro-averaged (weighted equally regardless of region size) within each organ, followed by macro-averaging across organs to obtain the reported mean Dice and mean IoU.
The nonlinear Dice–IoU conversion () holds per sample, but not after macro-averaging: $$For example, consider two slices with Dice of 1.0 and 0.1. Their mean Dice is 0.55. The corresponding IoU are 1.0 and 0.0526, giving a mean IoU of 0.5263. In contrast, converting the mean Dice directly via IoU-Dice relationship would yield 0.55/(2−0.55)=0.3793.
Question6: sensitivity of SID to HU windows and organ masks
Thank you for this question. We will add the following clarifications in the revised manuscript.
HU windows. All experiments use a unified preprocessing where CT is clipped to [−1000, 1000] HU. This is a standard practice to remove air and noise. SID internally applies multiple HU windows that provide non-exclusive but full coverage of [−1000, 1000] HU, allowing the focus on different tissue intervals. The same window setting is used for both AutoPET and SegRap without dataset-specific tuning. For normal anatomical CT, fixed windows are sufficient; for disease-specific tasks (e.g., lung lesions), window weights could be adjusted, which we leave for future work.
Organ masks. SID does not rely on a fixed organ sets. It computes distribution constraints only for annotated organs and averages across valid organs, preventing small structures from being dominated by large ones. Thus, although AutoPET and SegRap have different organ sets, SID could apply directly without redesign.
Notably, different HU window and organ choices may affect the improvement. This depends on dataset quality and anatomical characteristics. Our unified settings already yield consistent gains across different baselines; further tuning or task-adaptive weighting could be explored in future work.
Response to limitation
We will discuss limitations more comorehensively. First, LS2 adds training-time and memory overhead during diffusion/flow training due to clean-image reconstruction and image-space loss computation, but incurs no extra inference cost. Second, LDM performance is bounded by frozen VAE reconstruction fidelity. Third, diffusion models have high inference latency. For time-critical applications like online adaptive radiotherapy, faster LS2-constrained frameworks are needed. Clinical deployment also requires real-time workflow validation, dosimetric assessment, and safety analysis.
Response to rebuttal
Thank you for the clarification. I now understand the high-level implementation of LS2 in latent diffusion models. However, I still have several questions.
-
Please provide the complete training objective and explain how LS2 is weighted relative to the standard denoising loss. The paper defines the components within LS2, but not how the full loss is balanced against the original diffusion objective.
-
My concern remains that the clean-image estimate may be unreliable at high-noise timesteps. The rebuttal states that no timestep weighting is used, but does not analyse whether the resulting loss values and gradients remain stable across timesteps. Also, I do not think my concern regarding flow models is fully addressed. Equation 12 provides a clean-image estimate for a linear-path. The rebuttal states that LS2 can be applied more generally whenever a differentiable clean-image estimate is available, but this requirement and the supported class of flow parameterizations should be stated explicitly in the paper. This scope limitation is not my main concern, but the claim should be made more precise.
-
Please clarify how LPIPS were computed. Were they calculated pairwise among the ten samples generated from the same mask, or against real images? If they are pairwise metrics, the lower LPIPS and lower 1 - SSIM indicate reduced perceptual and structural diversity. The statement that only implausible variation has been removed is only stated but not supported. I understand image attachments are not allowed, please provide other analysis such as histogram distributions etc.
-
Thank you for explaining the averaging scheme. I understand the usual Dice–IoU relationship does not necessarily hold after averaging. I only wanted to point oout that a break of this relation suggests a highly skewed distribution. **I will not treat this as a main concern for now. **
Overall, I still find the presentation in both the paper and the rebuttal problematic. Several implementation and evaluation details are needed to help the reader understand and reproduce the method, while they are missing or only partially explained. This substantially harms the paper’s clarity and weakens its claims of broad compatibility and robustness. I will be very happy to raise my score if I get clarification on these points.
Response to question 1
Thank you for this helpful suggestion, which improves the clarity of the manuscript. The clarification will be added to the revised manuscript. The complete training objective of LDM and clarification about how is weighted relative to the standard denoising loss are as follows.
Specifically, given a real CT image and its mask , we first encode the image into the latent space as where is the encoder of the frozen VAE.
The forward diffusion process is defined as $ z_t = \sqrt{\bar{\alpha}_t}z_0 + \sqrt{1-\bar{\alpha}_t}\ \epsilon, \epsilon\sim\mathcal N(0,I)$, where is the sampled diffusion timestep and is determined by the cumulative noise schedule.
Given the noise prediction produced by the denoising network, the clean-image estimate is $$ Here, is the decoder of the frozen VAE.
Following Equation (1)-(5) in manuscript, is calculated directly between the real CT image and the decoded clean-image estimate: $$.
After Integrating into denoising loss of LDM, the complete training objective of LDM could be defined as:
where .
Thus, the complete term is added to the original denoising objective with an external weighting coefficient of 1.
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes LS2, a CT-specific objective for mask-guided CT synthesis. LS2 combines a Semantic Intensity Distribution loss, aligning HU distributions within clinical-window and anatomical-mask subspaces, with a Structural Anatomy loss based on smoothed gradient maps. The loss is integrated into GAN, diffusion, flow, and 3D foundation-model settings and evaluated on SegRap and AutoPET, with quantitative metrics, a user study, and downstream segmentation experiments.
Strengths and weaknesses
The paper addresses an important limitation of synthetic CT evaluation: global realism metrics may miss organ-specific HU shifts and structural hallucinations. The proposed objective is simple, CT-aware, and broadly applicable. The empirical section is broad, covering multiple generative paradigms, two datasets, CT-specific HU-W1 evaluation, a user study, 3D model adaptation, and downstream segmentation.
The main weakness is overclaiming in the frequency/causal discussion. The analysis provides useful intuition about distribution and gradient constraints, but it does not establish a formal causal result. The method also depends on semantic masks and clinical windows, so robustness to incomplete or noisy masks is important but not sufficiently tested. Some results need more explanation, especially the downstream segmentation table where synthetic-data training appears to outperform training with real data by a large margin for several organs. User-study details such as reader count, expertise, blinding, randomization, and inter-rater agreement should be clearer.
Questions
-
Please reframe or formally substantiate the "causal" frequency discussion; otherwise it should be presented as intuition or spectral analysis.
-
How robust is LS2 to incomplete, noisy, or coarse masks? Perturbation or label-drop experiments would help.
-
Please clarify the downstream segmentation setup, including whether synthetic data augments or replaces real data, the data sizes, splits, and variance.
-
Please provide full user-study details: reader number, expertise, blinding, randomization, scoring aggregation, and inter-rater agreement.
-
For the MAISI-v2 experiment, please explain the low absolute SegRap performance and provide evidence of meaningful 3D consistency.
Limitations
The paper mentions reliance on annotations and focus on normal anatomy rather than lesion-aware synthesis. The limitations should also discuss mask noise/incompleteness, dataset/site bias, and risks of using synthetic CTs for radiotherapy or downstream training without validation.
Final justification
The rebuttal resolved my main concerns by defining the spectral metrics, adding matched mask-robustness experiments and patient-level segmentation analysis, and clarifying the evaluation variability. The authors also appropriately tempered the claims regarding causality, synthetic-only training, reader-study equivalence, and 3D consistency. Although clinical validation remains limited, the additional evidence and revised positioning outweigh these limitations. I therefore recommend acceptance.
Formatting concerns
There are several typos and notation/formatting issues, including "Quantatitve", "frequency domann", inconsistent loss notation, and some garbled figure-label symbols.
8 comments
Rebuttal
Quetion1: revision to "causal" frequency discussion
We agree that "causal perspective" is inappropriate and will revise it. We will also add data analysis and spectral validation of frequency improvement to better support our claims in the revised manuscript.
Intuitively, compared with arbitrary image patches, patches within anatomical masks exhibit more concentrated HU distributions and lower spatial intensity variation in CT. In AutoPET, organ-mask patches show substantially lower intensity variation (std: 48.53 vs. 157.15; IQR: 46.09 vs. 159.50; median absolute deviation: 20.35 vs. 37.42) and smaller gradient magnitudes (mean gradient: 12.68 vs. 22.31; total variation: 24.87 vs. 35.97) compared to random patches. This provides empirical support for the link between organ-level distribution constraints and low-frequency consistency.
We clarify that our claim is not that SID theoretically guarantees low-frequency alignment for all images. Rather, the observed spectral improvements are an empirical byproduct of semantic-structural regularization on medical CT data, where organ-level intensity distributions are inherently constrained.
As for additional spectral validation, we compared SID with the differentiable histogram loss in [1] (suggested by reviewer 4Kg1), applied either globally or within organ masks under the same pix2pixHD settings in Table 1 of paper. The baseline low-frequency error (LF error) was 0.491±0.061. The global histogram loss reduced it to 0.480±0.062, whereas the organ-wise histogram loss further reduced it to 0.451±0.058. The high-frequency error (HF error) remained almost unchanged for the organ-wise histogram loss (0.416±0.042 vs. 0.418±0.043 for the baseline), while HU-W1 improved from 188.706±4.960 to 167.553±15.672.
Notably, SID produced a larger improvement compared to [1], reducing HU-W1 to 162.303±21.320 and LF error to 0.391±0.051, a reduction of approximately 20.4% from the baseline. Its HF error remained close to the baseline at 0.408±0.037, indicating that its main effect is organ-aware HU alignment accompanied by improved low-frequency spectral consistency, rather than uniform improvement across all frequency bands. In contrast, SA had little effect on the LF error but reduced the HF error to 0.295±0.013. Combining SID and SA, LS2 achieved LF and HF errors of 0.389±0.047 and 0.287±0.022, respectively, together with the best SSIM of 0.752±0.048 and the lowest HU-W1 of 159.242±4.668.
[1] M. Avi-Aharon, A. Arbelle, and T. Riklin Raviv, “Differentiable Histogram Loss Functions for Intensity-Based Image-to-Image Translation,” IEEE Transactions on Pattern Analysis and Machine Intelligence, vol. 45, no. 10, pp. 11642–11653, Oct. 2023, doi: 10.1109/TPAMI.2023.3278287.
Quetion2: perturbation and label-drop experiments for robustness analysis
Thank you for the suggestion. We further evaluated LS2 under incomplete and coarse conditioning masks on the AutoPET test set. And we will add the quantitative results and visual examples to the supplementary material.Two perturbations were considered: (1) randomly dropping 50% of organ labels to simulate incomplete annotations, and (2) downsampling masks by a factor of 2 and resizing them back to the original resolution to simulate coarse masks.
As expected, label removal degraded both models. Under 50% label drop, SSIM dropped from 0.760±0.054 to 0.745±0.084 for LDM and from 0.771±0.053 to 0.749±0.077 for LDM+LS2; PSNR dropped from 23.247±2.492 to 22.845±2.683 and from 23.515±2.548 to 22.723±2.648, respectively. Visual inspection confirmed boundary misalignment in removed regions.
Nevertheless, LDM+LS2 consistently achieved lower FID than LDM under this conditions, 18.131±0.099 vs. 20.187±0.121 with complete masks, 21.973±0.189 vs. 24.586±0.210 with 50% label drop. This indicates that LS2 preserves a distribution closer to real CT even when the conditioning masks are degraded.
Additionally, LS2 was particularly stable under coarse-mask perturbation. LDM+LS2 achieved an SSIM of 0.768±0.047 and a PSNR of 23.517±2.573, close to its performance with complete masks (0.771±0.053 and 23.515±2.548). Overall, LS2 tolerates moderate boundary coarsening, although substantial label removal still degrades generation quality.
Question3: downstream segmentation setup and result explanation
We will clarify the downstream segmentation protocol, report variability for the evaluation results, and discuss why synthetic-only training may outperform real-only training.
Segmentation experiments used the same patient-wise split as synthesis (90/20/10 for train/val/test on SegRap), with no patient overlap. All segmentation models were trained and validated solely on synthetic CTs paired with real masks. The same patients, masks, and sample sizes were used across all segmentation experiments. Evaluation was conducted exclusively on real CTs and real masks from unseen test patients. Therefore, this is a synthetic-to-real evaluation rather than a real-data augmentation setting.
The variability for the evaluation results are shown in the following table.
Why synthetic-only outperformed real-only: (1) Synthetic CTs are more standardized, with less scanner noise, acting as regularization. (2) Real CTs and manual annotations may have boundary misalignment, while synthetic CTs provide more label-consistent training pairs.
Importantly, we do not claim that synthetic data are superior to real data. LDM data generated with LS2 achieved better performance on the independent real test set, indicating improved synthetic-to-real transfer utility. Nevertheless, the experiment was conducted on only 10 test patients from the single-center SegRap dataset. The result should therefore be interpreted cautiously and larger multi-center studies are required for synthetic and real comparison.
Question 4: user study details
We will add full reader study details in the revision.
A associate consultant radiologist (13 years of experience) independently evaluated 100 randomly selected masks, each paired with real CT and synthetic CT (100 real pairs + 100 synthetic pairs). All samples were mixed and presented in a randomized order. Each image–mask pair was stored separately, and all information indicating image origin was removed to ensure blinded evaluation.
In evaluation, each pair was scored 0–2 for image realism and boundary consistency. Results are reported as counts and proportions of scores 0/1/2 per group. Since only one radiologist participated, inter-rater agreement was not assessed. We will acknowledge this as a limitation.
Question5: MAISI-v2 in Segrap and 3D consistency
Thank you for your question. MAISI-v2 underperforms on SegRap2023 mainly due to label-space mismatch. MAISI-v2 was pretrained on whole-body labels, while SegRap2023 uses fine-grained head-and-neck structures. Only ~11% of labels overlap (brain, spinal cord, thyroid, trachea, esophagus). SegRap-specific labels (optic nerves, ear structures, target volumes, overlapping combinations) are absent in MAISI-v2. Thus, poor performance reflects cross-domain transfer difficulty
To assess 3D consistency, we reconstructed consecutive slices into full CT volumes and computed patient-level 3D PSNR and 3D SSIM. On SegRap, adding LS2 improved 3D PSNR from 16.623±0.803 to 16.999±0.811 and 3D SSIM from 0.301±0.076 to 0.322±0.072.
We also evaluated multiplanar consistency. In addition to the axial-view results reported in Table 1, sagittal-view SSIM improved from 0.2542±0.1080 to 0.2722±0.1009, while coronal-view SSIM improved from 0.2515±0.0063 to 0.2694±0.0078. Although the gains are modest, they consistently indicate improved volumetric and cross-plane consistency with LS2. We will add these 3D and multiplanar results for all compared methods in the revised manuscript.
Response to limitation
We thank the reviewer for this suggestion. We will add the following limitations in the revised manuscript.
First, segmentation quality dependence. Perturbation experiments show that LS2 tolerates segmentation errors to some extent, but is not unaffected. With 50% random label dropout, SSIM dropped from 0.771±0.053 to 0.749±0.077, indicating that severe label incompleteness still degrades generation quality.
Second, dataset and site bias. The models were trained separately on SegRap and AutoPET, and may have learned site-specific imaging distributions. Cross-center generalizability remains to be validated through multi-center external testing and domain adaptation methods.
Third, clinical application risks. Before being used for radiotherapy dose calculation or downstream model training, multi-center prospective evaluation is required. For radiotherapy use cases, dosimetric validation and strict quality control are additionally necessary.
Thank you for the detailed rebuttal. Retracting the causal terminology and adding histogram-loss, mask-perturbation, downstream, and volumetric experiments substantially address my concerns. Before finalizing my assessment, I would appreciate clarification on a few points. Please define the LF/HF errors, frequency cutoff, normalization, and the unit represented by ±. For mask robustness, were perturbations applied only at test time, and can you report the matched LDM result under coarse masks? Under 50% label drop, LS2 improves FID and slightly improves SSIM, but not PSNR, so the robustness claim should remain metric-specific. For downstream segmentation, please state whether variability is across patients, organs, seeds, or slices, and provide a paired patient-level LDM versus LDM+LS2 comparison if possible. The explanations for synthetic-only outperforming real-only should be presented as hypotheses unless directly validated. Finally, a single-reader study and do not establish clinical equivalence or indistinguishability. Similarly, metrics computed from stacked 2D slices demonstrate volumetric fidelity but do not directly isolate inter-slice consistency. Please temper these conclusions accordingly. Subject to these clarifications, I am inclined to raise my assessment.
Definitions of LF/HF errors, frequency cutoff, normalization, and ± unit.
Thank you for your question. We are sorry that we did not provide them due to space limit last time. We would like to provide these definitions and also state them in revised manuscript.
For each matched real and synthesized image pair, both images were first converted to grayscale and normalized with pixel intensities in [0,1].
Let and denote the resulting real and synthesized images, respectively. Their centered two-dimensional discrete Fourier transforms were computed as
The corresponding log-magnitude spectra were defined as $$
We then calculate the absolute log-spectral error map:
After applying , the zero-frequency component was relocated to the center of the spectrum. For each CT slice, the normalized radial coordinate was defined as where is center coordinate. Thus, ranges from 0 at the center of the shifted spectrum to 1 at the farthest corner of the frequency grid.
**The low- and high-frequency regions were defined using the relative radial-frequency thresholds and , respectively:
Regarding normalization, the image intensities were normalized to [0,1], while the radial frequency coordinate was normalized by the maximum radius of the discrete Fourier grid. The FFT magnitude itself was not additionally normalized; only the log(1+∣F∣) transformation was applied to compress its dynamic range. Because all images were processed at the same fixed resolution of 256×256, the spectral scale was consistent across all compared methods. The thresholds 0.25 and 0.50 therefore represent relative radial frequencies rather than physical frequencies in Hz, cycles/pixel, or cycles/mm.
For a test set containing matched two-dimensional slice pairs, LF and HF errors were first calculated separately for each pair. The reported results are the across-image mean and sample standard deviation:
Accordingly, the symbol “±” denotes the sample standard deviation across matched two-dimensional slice pairs, rather than the standard error, variance, confidence interval, or patient-level variability. The standard deviation therefore has the same scale as the corresponding LF/HF error. And both the LF/HF means and their standard deviations are reported in dimensionless log-spectral-error units.
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes a mask-guided conditional CT synthesis framework designed to address a domain-specific challenge in CT generation: a synthesized image may appear visually realistic while still exhibiting anatomically incorrect Hounsfield Unit (HU) distributions. Given an anatomical segmentation mask as a condition, an existing conditional generator produces a synthetic CT image. The authors introduce two additional losses: (), which aligns region-wise HU distributions, and (), which encourages structural agreement through relaxed gradient-map alignment.
The proposed losses are evaluated with several existing conditional generative backbones, including GAN-, diffusion-, and flow-based models, on two CT datasets, SegRap and the whole-body dataset described as AutoPET. The ablation studies suggest that both losses contribute to improved synthesis performance. The paper additionally evaluates the generated images using image-quality metrics, a user study, and a downstream segmentation experiment.
Overall, I view the main contributions as follows: (1) a well-motivated formulation of CT-specific synthesis objectives, particularly for preserving anatomically meaningful HU distributions; (2) two generator- agnostic regularization losses intended to improve regional intensity fidelity and spatial structure; and (3) an empirical evaluation across multiple types of conditional generative backbones.
Strengths and weaknesses
[Strengths] The paper tackles domain-specific problem using well-motivated solutions. The paper shows the generalizability of their proposed losses over multiple different backbone models and evaluates on multiple different protocols (metrics, methods, datasets). In detail:
- (Significance, Originality) The paper addresses a relevant and well-motivated domain-specific problem. In CT synthesis, perceptual realism alone does not guarantee that anatomically specific HU distributions are preserved. The proposed region-aware formulation directly targets this issue.
- (Quality) The proposed losses are evaluated using multiple generator families, including GAN-, diffusion-, and flow-based models. This supports the claim that the losses are not tightly to a particular generator architecture.
- (Quality) The paper uses several complementary evaluation protocols, including conventional image-quality metrics, region-wise HU evaluation, downstream segmentation, mask-fidelity analysis, and a user study. This is potentially more informative than relying on perceptual image-quality metrics alone.
[Weaknesses]
- (Clarity/ Major) Missing dataset splits and statistical reporting. The paper does not provide train/validation/test split counts or ratios. It is also unclear whether the split was performed at the patient level or at the 2D slice lee. This is particularly important in this field/study. This is a critical miss. Furthermore, the quantitative results do not report variability such as patient-level statistical analyses including confidence intervals. This shows the model stability, which is crucial in this study. These should be addressed for Paper Checklist #6 and #7.
- (Clarity/ Major) Insufficient description of the downstream segmentation experiment. The downstream segmentation experiment is potentially valuable, but its protocol is not described in enough detail to interpret Table 2. Specifically, the paper should clarify in which data the downstream model is trained (synthetic or real) and evaluated (real or synthetic). Refer [1]'s "synthetic-to-real" as an example.
- (Quality/ Major) The low-frequency interpretation in Section 3.3.1 is insufficiently justified. The mathematical motivation in 3.3.1 is not fully convincing. The observation, about that Fourier transform of a rectangular mask has a sinc-like form and this corresponds to convolution in the frequency domain, is plausible. But, these facts do not by themselves establish that minimizing () specifically aligns low-frequency components. The SID loss compares the marginal distributions of HU values within each anatomical mask and is invariant to spatial permutations within that mask. The author may empirically prove this by comparing it with other distributional regularizer like [2]. But without empirical experiments or more direct proof, I am concerned about mathematical correctness of this.
- (Quality/ Minor) Applicability in practice. The proposed method depends on accurate segmentation conditions. In practice, the users should have accurate segmentation maps to generate. This limits the potential usage in the practice. One possible way I can think of is data augmentation. Users can probably use it to augment the data using same segmentation, but this is narrow in applicability. If the authors have potential usage of this technique in practice, mentioning in the paper will strength the potential more.
- (Quality/ Major) Background slices in evaluation. In 2D slice-by-slice aggregated evaluation, how was background slices were treated? Also, in this data (where samples are volumetric), more valuable and intuitive metrics would be 3D-based. If 3D-based evaluation can be done, I think author(s) should consider switching to 3D-based or add an additional 3D-based metrics.
- (Quality, Clarity/ Major) Missing details about the segmentation condition. The paper does not show the details about the prior condition to the generation model. How does segmentation condition structured?
[1] J. Ha, J. S. Park, D. Crandall, E. Garyfallidis, and X. Zhang, “Multi-Resolution Guided 3D GANs for Medical Image Translation,” in Proceedings of the IEEE/CVF Winter Conference on Applications of Computer Vision (WACV), 2025, pp. 4342–4351.
[2] M. Avi-Aharon, A. Arbelle, and T. Riklin Raviv, “Differentiable Histogram Loss Functions for Intensity-Based Image-to-Image Translation,” IEEE Transactions on Pattern Analysis and Machine Intelligence, vol. 45, no. 10, pp. 11642–11653, Oct. 2023, doi: 10.1109/TPAMI.2023.3278287.
Questions
In general, the paper misses details in writing as my major concerns. Addressing the questions and concerns in the weaknesses can help improve the quality of the paper dramatically. Please refer the weaknesses for questions.
And for the further experiments, adding 3D-based metrics would make the evaluation much relevant to the topic (since the datasets are inherently volumetric) and I believe this is not hard since it's only evaluation, not training.
Limitations
Yes
Final justification
I raised 6 concerns (data-split, protocols for downstream experiment, frequency interpretation, applicability, missing 3d metrics, implementation details for conditional input) as weaknesses and the author either verbally answered and provided the empirical supports to address the concerns. Other than applicability (I partially credit the rebuttal comments, but this was minor), the rebuttal comments were reasonable. Adding the details about the missing parts from all reviewers' comments and additional experiments conducted in the revision can make the paper much stronger. I therefore raise my rating to accept.
Formatting concerns
I don't have any concern about paper formatting
4 comments
Rebuttal
Weakness1 and 5: dataset splits and 2/3D statistical variability
Following your suggestion, we will clarify the data splits and report variability for all quantitative results.
All experiments used a patient-wise data split with disjoint patient cohorts across training, validation, and test sets. AutoPET included 370/108/55 patients (69.5%/20.3%/10.3%), while SegRap included 90/20/10 patients (75.0%/16.7%/8.3%). The same patient-level splits were used for all generative models and downstream segmentation experiments.
For the original slice-level evaluation, background slices were excluded before model development and evaluation, and all results are now reported as mean±std. We will additionally provide patient-level 3D metrics, including 3D SSIM and 3D PSNR, to quantify inter-patient variability. FID, LFD, and HU-W1 remain evaluated at the slice level, as these metrics are inherently defined on 2D images or 2D image distributions. Due to space limitations, we only report the revised slice-level and 3D results for SegRap as follows.
Weakness2: downstream segmentation protocol
We performed segmentation experiments on SegRap using the same patient-wise split as synthesis (no patient overlap across sets) (see details in “[Weaknesses 1 and 5: Dataset splits and 2D/3D statistical variability]” ). All segmentation models in Table 2 were trained and validated solely on synthetic CT images paired with real masks; therefore, this experiment is not a real-data augmentation setting. The same patients, masks, and sample sizes were used across all segmentation experiments. Evaluation was conducted exclusively on real CT images and real masks from unseen test patients, which is the same as the synthetic-to-real protocol in [1]. Thus, Table 2 evaluates the downstream synthetic-to-real transferability of the generated CTs. This shows that synthetic CT from LDM+LS2 outperforms that from LDM, but does not imply that synthetic CT is superior to real clinical data, as the evaluation was conducted on the single-center SegRap dataset.
Weakness3: low-frequency interpretation in Section 3.3.1
We agree that SID matches the marginal HU distribution within each anatomical mask and is invariant to spatial permutations within that mask; therefore, it does not directly enforce frequency-domain constraints. We have revised Section 3.3.1 to clarify this point and provide additional empirical evidence as suggested.
First, unlike arbitrary patches, HU distributions within organ masks are more concentrated and smoother. In AutoPET, organ-mask patches show substantially lower intensity variation (std: 48.53 vs. 157.15; IQR: 46.09 vs. 159.50; median absolute deviation: 20.35 vs. 37.42) and smaller gradient magnitudes (mean gradient: 12.68 vs. 22.31; total variation: 24.87 vs. 35.97) compared to random patches. This provides empirical support for the link between organ-level distribution constraints and low-frequency consistency.
We clarify that our claim is not that SID theoretically guarantees low-frequency alignment for all images. Rather, the observed spectral improvements are an empirical byproduct of semantic-structural regularization on medical CT data, where organ-level intensity distributions are inherently constrained.
Following your suggestion, we compared SID with the differentiable histogram loss in [2], applied either globally or within organ masks under the same pix2pixHD settings in Table 1 of paper. As shown in the following table, the baseline low-frequency error (LF error) was 0.491±0.061. The global histogram loss ([2]-global) reduced it to 0.480±0.062, whereas the organ-wise histogram loss ([2]-organ) further reduced it to 0.451±0.058. The high-frequency error (HF error) remained almost unchanged for the organ-wise histogram loss (0.416±0.042 vs. 0.418±0.043 for the baseline), while HU-W1 improved from 188.706±4.960 to 167.553±15.672.
Notably, SID produced a larger improvement compared to [2], reducing HU-W1 to 162.303±21.320 and LF error to 0.391±0.051, a reduction of approximately 20.4% from the baseline. Its HF error remained close to the baseline at 0.408±0.037, indicating that its main effect is organ-aware HU alignment accompanied by improved low-frequency spectral consistency, rather than uniform improvement across all frequency bands. In contrast, SA had little effect on the LF error but reduced the HF error to 0.295±0.013. Combining SID and SA, LS2 achieved LF and HF errors of 0.389±0.047 and 0.287±0.022, respectively, together with the best SSIM of 0.752±0.048 and the lowest HU-W1 of 159.242±4.668.
Weakness4: applicability in practice
Thank you for this suggestion. We agree that reliance on accurate segmentation limits direct applicability, but note that this is a shared limitation of conditional generation models (e.g., pix2pixHD). We will expand the discussion in main text to clarify practical usage from three perspectives.
(1) Adaptive radiotherapy. As described in Section J, LS2 can be integrated into adaptive radiotherapy workflows. Organ boundaries can be rapidly obtained via fiducial markers, respiratory gating, or motion management, enabling synthetic CT generation for plan adaptation, dose verification, and risk control. This process offers substantially faster turnaround than conventional imaging.. Here, LS2 could reduce intensity shifts for more reliable dose calculation, and suppress anatomical hallucinations to assist contour quality assurance. However, clinical utility requires prospective validation.
(2) The improved HU consistency and reduced structural hallucinations also make LS2-generated CT useful for phantom design, digital phantoms, and radiotherapy education applications.
(3) Robustness to imperfect segmentation. We conducted additional sensitivity experiments. With 50% random label dropout, SSIM dropped from 0.771±0.053 to 0.749±0.077 and PSNR from 23.515±2.548 to 22.723±2.648, performance degrades but remains reasonable. Facing coarse mask, SSIM and PSNR were 0.768±0.047 and 23.517±2.573, nearly identical to the original mask (0.771±0.053 and 23.515±2.548). These results indicate that LS2, while segmentation-dependent, tolerates coarse or partially annotated masks to some extent.
Weakness6: details of segmentation condition
We will add the protocol of constructing segmentation condition in the revised manuscript.
The segmentation condition is a single-channel discrete label map, spatially aligned with the corresponding CT and sliced axially into 2D slices. In each label map, 0 denotes background, and different positive integers represent different anatomical classes. For AutoPET, we directly use the original category IDs. For SegRap, since some anatomical structures spatially overlap, we assign a unique integer label to each distinct combination of overlapping structures (e.g., overlapping regions are encoded as unique integers outside the original label range). This mapping is kept consistent across training, validation, and test sets, preserving overlap information within a single-channel label map.
Too broad comments for applicability
For the dependence on segmentation masks and practical applicability, the authors explained that this is an inherent limitation of conditional image generation methods (e.g., pix2pix), and that the proposed method can still be valuable for (a) adaptive radiotherapy, (b) improved generation with better HU and structural consistency, which may be useful for phantom design, digital phantoms, and radiotherapy education, and (c) robustness to imperfect segmentation. Claim (a) is probably too strong, as it may require additional experimental support. Claim (b) is plausible because masks may be intentionally available in those settings. Claim (c) is also plausible, although the current evidence is somewhat limited because the mask imperfections were simulated through test-time label dropout and downsampling rather than obtained from realistic segmentation-model errors. Adding (b) as a motivational statement somewhere in the paper could help readers better understand the practical value of the method. The other applications may be beyond the scope of this paper and could be further validated in future work.
Interpretation about frequency related to loss
I appreciate the authors providing LF and HR error (with equation).
For the contribution and interpretation of the losses in the frequency domain, the authors showed their effects empirically using LF/HF errors. Adding the table as an ablation study, together with the definitions of the LF/HF errors, would better demonstrate the contributions of the losses across different frequency bands. However, I believe the authors should still tone down the theoretical interpretation of this relationship. The new results provide useful empirical evidence, but they do not establish that minimizing SID mathematically implies low-frequency alignment.
Response to reviewer 4Kg1
We thank the reviewer for the positive feedback and constructive suggestions.
Frequency-related interpretation. We will add an ablation table with the definitions of LF/HF errors to better illustrate the frequency-band contributions of each loss. We also agree that the theoretical interpretation should be toned down. We will revise the manuscript accordingly.
Applicability statement. We will rephrase (a) as future work, add (b) as a motivational statement for helping readers better understand the practical value of the method in the paper, and acknowledge (c) as limited to simulated mask degradations, with validation on real segmentation errors left for future work. Other applications are beyond this scope.
We sincerely appreciate the reviewer's time and insights, which have significantly strengthened our manuscript.
Comments on the paper
1 comment
Final justification
The discussion period is coming to an end, and the next task for all reviewers is to make a final justification and possibly update the rating. (You can do so by selecting the review “Edit->Official Review” button. “Rating” changes during Phase 3 are not visible to authors until paper decisions are made visible.)
If you have any outstanding questions for the authors, now is the time.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Response to Major concern 1 in meta review: “causal” terminology and empirical observation of SID
We agree that "causal perspective" is inappropriate and will drop it. We will also add data analysis and spectral validation of frequency improvement to better support low-frequency claim in the revised manuscript.
Intuitively, compared with arbitrary image patches, patches within anatomical masks exhibit more concentrated HU distributions and lower spatial intensity variation in CT. In AutoPET, organ-mask patches show substantially lower intensity variation (std: 48.53 vs. 157.15; IQR: 46.09 vs. 159.50; median absolute deviation: 20.35 vs. 37.42) and smaller gradient magnitudes (mean gradient: 12.68 vs. 22.31; total variation: 24.87 vs. 35.97) compared to random patches. This provides empirical support for the link between organ-level distribution constraints and low-frequency consistency.
We clarify that our claim is not that SID theoretically guarantees low-frequency alignment for all images. Rather, the observed spectral improvements are an empirical byproduct of semantic-structural regularization on medical CT data, where organ-level intensity distributions are inherently constrained.
As for additional spectral validation, we compared SID with the differentiable histogram loss in [1] (suggested by reviewer 4Kg1), applied either globally or within organ masks under the same pix2pixHD settings in Table 1 of paper. The baseline low-frequency error (LF error) was 0.491±0.061. The global histogram loss reduced it to 0.480±0.062, whereas the organ-wise histogram loss further reduced it to 0.451±0.058. The high-frequency error (HF error) remained almost unchanged for the organ-wise histogram loss (0.416±0.042 vs. 0.418±0.043 for the baseline), while HU-W1 improved from 188.706±4.960 to 167.553±15.672. These results indicate that **organ-level intensity regularization improves low-frequency consistency, while global histogram constraints are less effective. **
Notably, SID produced a larger improvement compared to [1], reducing HU-W1 to 162.303±21.320 and LF error to 0.391±0.051, a reduction of approximately 20.4% from the baseline. Its HF error remained close to the baseline at 0.408±0.037, indicating that its main effect is organ-aware HU alignment accompanied by improved low-frequency spectral consistency, rather than uniform improvement across all frequency bands. In contrast, SA had little effect on the LF error but reduced the HF error to 0.295±0.013. Combining SID and SA, LS2 achieved LF and HF errors of 0.389±0.047 and 0.287±0.022, respectively, together with the best SSIM of 0.752±0.048 and the lowest HU-W1 of 159.242±4.668. Together, SID and SA are complementary. SID targets organ-level intensity and low-frequency consistency, while SA enhances high-frequency structures; their combination yields the best overall performance.
[1] M. Avi-Aharon, A. Arbelle, and T. Riklin Raviv, “Differentiable Histogram Loss Functions for Intensity-Based Image-to-Image Translation,” IEEE Transactions on Pattern Analysis and Machine Intelligence, vol. 45, no. 10, pp. 11642–11653, Oct. 2023, doi: 10.1109/TPAMI.2023.3278287.