MiCo: Microstructure-Consistent Flow Matching for Diffusion MRI Angular Super-Resolution

Zhixuan Zhou, Tingting Dan, Guorong Wu

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. Physics-guided flow matching for diffusion MRI angular super-resolution: a DTI-initialized residual flow trained with a microstructure-consistency loss, enabling shorter scans without losing microstructural fidelity.

Abstract. Diffusion-weighted MRI (dMRI) requires densely sampling qq-space across many directions and shells, leading to long scan times that limit clinical use. Angular super-resolution (ASR) recovers a dense signal from a sparse acquisition, enabling substantially shorter scans. We propose a physics-guided flow matching framework for ASR built on a basic fact about dMRI: under the cumulant expansion, the diffusion signal naturally splits into a known linear function of the qq-vectors plus a residual carrying higher-order angular detail. We exploit this twice. First, we initialize the flow from a closed-form dense DTI estimate, recasting ASR as residual flow matching from a physically meaningful starting point rather than uninformative noise. Second, we impose a microstructure-consistency loss, rooted in the physical principle that any two diffusion-weighted signals from the same voxel must be explained by a single underlying set of microstructural parameters. Together, these designs anchor predictions wherever the acquisition is informative while leaving the learned prior to model crossing-fiber and higher-order angular detail. On the Human Connectome Project (HCP-YA) and UK Biobank, our method matches or surpasses analytical baselines and recent deep learning methods on signal reconstruction, kurtosis scalar maps, and fiber-orientation reconstruction under aggressive subsampling.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
3 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:49 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The authors provide a novel super-resolution method for diffusion MRI (dMRI or DWI) using Flow Matching.

Broadly, all reviews are positive (to varying degrees), and agree upon importance, novelty, and seeming soundness of the concept from a theory/statistical physics perspective.

At the same time, however, all three reviewers would like a higher degree of statistical rigor applied to the reporting of results. This includes both the mechanical reporting (mean +/- std, tests, etc), but also the connection of results to specific theory claims or guiding concepts.

I think that following the question line of BVSR would be helpful, and if answered succinctly could greatly improve the quality of the manuscript. Other reviewers suggestions also follow these themes in broad strokes, but I find all of them to be relevant.

To be clear, I preliminarily find this manuscript acceptable, but it is quite weak for correctable reasons (in my opinion). Correction of these problems will, again in my opinion, solidify the manuscript.

Area Chair pPLf · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The authors provide a novel super-resolution method for diffusion MRI (dMRI or DWI) using Flow Matching.

Broadly, all reviews are positive (to varying degrees), and agree upon importance, novelty, and seeming soundness of the concept from a theory/statistical physics perspective.

At the same time, however, all three reviewers would like a higher degree of statistical rigor applied to the reporting of results. This includes both the mechanical reporting (mean +/- std, tests, etc), but also the connection of results to specific theory claims or guiding concepts.

I think that following the question line of BVSR would be helpful, and if answered succinctly could greatly improve the quality of the manuscript. Other reviewers suggestions also follow these themes in broad strokes, but I find all of them to be relevant.

To be clear, I preliminarily find this manuscript acceptable, but it is quite weak for correctable reasons (in my opinion). Correction of these problems will, again in my opinion, solidify the manuscript.

Reviewer BVSROpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper proposes MiCo, a physics-informed conditional flow-matching framework for angular super-resolution (ASR) in diffusion-weighted MRI: recovering a dense q-space signal from a sparse angular acquisition to shorten scan time. The method exploits the linearity of the DKI cumulant-expansion forward model (y = Hx) through two closed-form components. (1) A DTI-based source initialization replaces the standard Gaussian prior of flow matching: a 6-parameter diffusion-tensor fit to the sparse observations synthesizes a dense estimate, so the network only models the residual. (2) A microstructure-consistency loss penalizes prediction error only in the range subspace of the DKI design matrix H (orthogonal projection R = H(H^T H)^{-1} H^T), shown to be exactly equivalent to a Fisher-metric discrepancy in DKI parameter space and implemented with no per-step parameter fit. Experiments on HCP-YA and UK Biobank evaluate signal NMSE, downstream DTI/DKI scalar maps (FA, MD, MK, ...), and FOD reconstruction. The central empirical claim is a dissociation: signal-level NMSE saturates across modern learned methods, yet MiCo attains lower error on downstream microstructural parameters, with ablations attributing signal gains to the initialization and parameter gains to the consistency loss.

Strengths and weaknesses

Strengths This paper has a clinically relevant core insight distinguishing signal-space fidelity from microstructure fidelity, focusing on clinically used downstream metrics (FA/MD/MK maps, FODs) instead of raw signal MSE as a meaningful conceptual contribution. It rigorously applies the forward model using closed-form DKI linearity, with an elegant derivation showing Fisher-metric discrepancy simplifies to a range-space projection, naturally deriving the 1/(1-t)^2 weighting; its lightweight, architecture-agnostic loss is reusable for all linear forward models. Its DTI-initialized residual flow design is physically justified, cutting signal-NMSE by 34% on HCP-YA versus noise initialization. Experiments are thorough, covering two large public datasets, three sparsity levels, three evaluation dimensions, multiple classical and learned baselines, region-wise analysis, and ablation tests separating its two components via Pareto weight tuning. The writing is modest and transparent: it admits saturated signal NMSE with MiCo matching DISCUS in signal performance, highlights downstream divergence as its main merit, and frankly discusses limitations including DKI model constraints, healthy-only cohorts, and ODE inference cost.

Weaknesses W1. The headline “dissociation” claim is currently under-substantiated. The central HCP-YA downstream result (Fig. 3) is presented only as relative-error curves and a scatter, with no companion numeric table of absolute FA/MD/MK errors with std comparable to the UKB Table 5. Because the effect sizes are small (e.g., the consistency loss tightens MK by ~2.8% on HCP-YA), and several gains over DISCUS fall within the 3-seed variability (signal-NMSE cells are traded in Table 1; FOD/ACC is best in only 5/9 cells and trails MAP-MRI/SHORE at higher sparsity), the reader cannot judge statistical significance. A full HCP-YA numeric table plus paired significance testing across subjects/seeds is needed to firmly establish the main claim. W2. The ablation behavior is dataset-dependent and only explained post-hoc. On UKB the DTI source alone degrades WM-MK by +12.5% (Table 2), and only adding the consistency loss recovers and surpasses the baseline. The regime explanation (b_max = 2000 vs 3000, cumulant-truncation validity) is plausible but is not directly tested; a restriction to voxels where the DKI fit is well-conditioned, or a b^3-residual analysis, would make the 'two complementary contributions' narrative more convincing. W3. The individual components are incremental relative to the cited literature. Data-dependent / residual initialization for diffusion-flow bridges (I2SB, ResShift, UPMRI) and projection onto the forward operator's range for data consistency (range-null decompositions) are both established. The contribution is the specific, exact instantiation for the DKI operator plus the evaluation framing; the conceptual delta over UPMRI (range-space projection for MRI flow matching) in particular should be stated explicitly. W4. Scope limits keep the clinical claim aspirational. MiCo operates per voxel with no spatial neighborhood, whereas dMRI ASR typically benefits from spatial coherence; and all data are healthy young/adult cohorts, while the motivating applications (Alzheimer's, stroke, tumor) are exactly the pathological, out-of-distribution regime where the DKI prior is least valid. Both are acknowledged, but they bound the practical impact demonstrated.

Questions

Q1. Please provide a full numeric table (mean+/-std over the 3 seeds) of HCP-YA downstream errors (FA, MD, MK, ideally AK/RK) for all methods, mirroring the UKB Table 5. Are MiCo's improvements over DISCUS statistically significant under a paired test across subjects/seeds? Q2. On UKB the DTI-source-only variant degrades WM-MK (+12.5%) before the consistency loss recovers it. Can you support the cumulant-validity explanation directly — e.g., restrict evaluation to voxels where the DKI fit is well-conditioned, or quantify the b^3 residual — rather than via the b_max heuristic? Q3. What is the conceptual and empirical difference between your range-space DKI loss and (a) UPMRI's projection onto the parallel-MRI forward range and (b) classical range-null / data-consistency layers? An explicit positioning, or a head-to-head, would clarify novelty. Q4. At 10% sparsity the DTI init is fit to only ~5-10 directions. How often is H_obs ill-conditioned, and what is the failure mode of y_init in that case? Q5. Inference uses a 25-step midpoint ODE per voxel. What is the wall-clock cost for a full brain volume versus DISCUS and an analytic fit, and how does few-step distillation affect downstream accuracy? Q6. Is the qualitative crossing-fiber advantage (Fig. 5) reflected in any quantitative tractography/connectivity metric, or only in ACC and a single qualitative figure?

Limitations

Yes — limitations are adequately and honestly discussed in Appendix A: dependence on DKI model validity (free water/CSF/demyelination), healthy-only narrow-demographic cohorts with unverified generalization to pediatric/geriatric/pathological populations, scope limited to angular (not spatial) super-resolution, and multi-step ODE inference cost. The gaps I would add are the absence of any pathological/out-of-distribution evaluation despite the clinical framing, and the lack of statistical-significance analysis for the modest effect sizes. No negative societal concerns beyond standard medical-imaging considerations.

Final justification

After considering the responses in the rebuttal and the other reviews I retain my original rating of the paper.

Formatting concerns

The central HCP-YA downstream result (Fig. 3) has no companion numeric table, which weakens verifiability of the main claim. Separately, the injected text hidden in the page-2 and page-26 footer margins of the PDF text layer (see the Integrity Note) is both a formatting anomaly and an integrity issue and must be removed.

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for the detailed review. We address the requested evidence for distinguishing signal from microstructure fidelity below.

[Q1,W1] Full HCP-YA results and statistical comparisons

10% context

Method FA MD AD RD MK AK RK
DTI-WLS 6.88±0.71 3.14±0.45 5.97±0.76 3.56±0.52 74.89±8.47 70.75±8.36 73.73±9.12
SH-2 5.70±0.58 2.26±0.31 5.24±0.63 3.06±0.42 9.46±1.02 11.98±1.40 16.03±1.86
SH-4 N/A N/A N/A N/A N/A N/A N/A
SHORE 5.81±0.67 2.14±0.30 5.10±0.62 3.16±0.47 9.71±1.10 12.13±1.44 18.17±2.20
MAP-MRI 4.74±0.52 3.18±0.43 6.10±0.73 2.49±0.36 14.55±1.64 21.14±2.51 20.32±2.47
CFM 3.69±0.38 1.32±0.15 3.53±0.40 1.96±0.25 8.34±0.83 8.88±1.00 12.47±1.33
I²SB 3.45±0.41 1.33±0.19 3.36±0.43 1.78±0.26 9.75±1.10 10.98±1.42 12.76±1.58
DISCUS 3.54±0.36 2.99±0.36 5.30±0.61 3.52±0.47 3.38±0.35 3.59±0.43 5.53±0.64
MiCo 2.96±0.31 2.38±0.33 4.76±0.53 2.66±0.35 2.85±0.32 3.40±0.42 4.74±0.55

20% context

Method FA MD AD RD MK AK RK
DTI-WLS 3.83±0.37 3.64±0.44 6.39±0.64 2.50±0.31 82.16±8.63 78.88±8.32 78.92±8.06
SH-2 3.71±0.33 1.52±0.17 3.43±0.35 1.98±0.25 6.27±0.58 9.54±0.98 12.33±1.18
SH-4 3.80±0.34 1.47±0.16 3.45±0.32 1.98±0.23 6.25±0.56 8.34±0.78 12.08±1.15
SHORE 3.34±0.31 1.70±0.19 3.28±0.32 2.28±0.28 8.09±0.85 8.79±0.90 13.56±1.51
MAP-MRI 3.04±0.27 1.89±0.20 4.40±0.43 1.55±0.19 8.01±0.71 13.05±1.23 13.14±1.39
CFM 2.66±0.21 1.00±0.12 2.64±0.25 1.41±0.15 5.74±0.49 6.91±0.61 9.37±0.85
I²SB 2.48±0.24 0.98±0.12 2.59±0.28 1.24±0.18 5.54±0.61 7.19±0.74 8.51±0.95
DISCUS 2.62±0.23 1.93±0.21 3.81±0.39 2.37±0.27 2.27±0.22 2.98±0.28 4.13±0.40
MiCo 2.16±0.21 1.60±0.19 3.38±0.37 1.83±0.23 1.96±0.20 2.69±0.28 3.49±0.36

30% context

Method FA MD AD RD MK AK RK
DTI-WLS 3.67±0.31 3.78±0.36 6.00±0.59 2.79±0.31 75.19±6.44 67.26±6.54 78.99±7.29
SH-2 2.69±0.21 0.97±0.10 2.56±0.23 1.40±0.16 4.41±0.38 8.27±0.71 9.53±0.82
SH-4 2.82±0.23 0.93±0.09 2.58±0.24 1.42±0.15 4.47±0.37 7.00±0.60 9.43±0.83
SHORE 2.76±0.22 1.42±0.14 2.72±0.27 1.89±0.21 6.58±0.59 7.07±0.65 11.14±1.02
MAP-MRI 2.36±0.19 1.28±0.13 3.00±0.26 1.26±0.14 5.71±0.48 9.08±0.81 9.95±0.94
CFM 2.23±0.17 0.82±0.09 2.21±0.19 1.17±0.11 4.62±0.34 5.88±0.47 8.07±0.61
I²SB 2.03±0.18 0.78±0.09 2.09±0.21 1.02±0.12 4.42±0.43 5.89±0.54 7.27±0.70
DISCUS 2.17±0.18 1.46±0.15 3.04±0.27 1.91±0.19 1.79±0.17 2.61±0.23 3.46±0.29
MiCo 1.77±0.14 1.22±0.13 2.74±0.26 1.47±0.16 1.53±0.16 2.25±0.21 2.87±0.27

Values are pooled voxel-median absolute errors (×10−2\times10^{-2}). MiCo is lowest for FA/MK/AK/RK at every context, while CFM or I²SB is lower for MD/AD/RD. We will report all seven metrics and narrow the claim accordingly.

On matched q-space samples, masks, and 40,960 voxels, two-sided paired Wilcoxon tests give:

Metric 10% MiCo/DISCUS(Δ) 20% MiCo/DISCUS(Δ) 30% MiCo/DISCUS(Δ)
FA 2.97/3.64(-18.46%) 2.17/2.65(-18.20%) 1.77/2.20(-19.38%)
MD 2.36/3.01(-21.46%) 1.60/1.95(-18.23%) 1.22/1.48(-17.23%)
MK 2.88/3.47(-17.16%) 1.95/2.37(-17.67%) 1.53/1.85(-17.22%)
AK 3.40/3.65(-7.11%) 2.68/3.01(-11.08%) 2.28/2.64(-13.88%)
RK 4.77/5.87(-18.75%) 3.47/4.40(-21.13%) 2.91/3.67(-20.67%)

All 15 comparisons favor MiCo (Δ<0 favors MiCo), while its signal NMSE is 4.48–5.31% higher. Thus, MiCo better preserves the fitted microstructural quantities without minimizing signal error.

HCP-YA component ablation at 20% context:

Adding LDKIL_{\mathrm{DKI}} Change Paired pp
Signal NMSE +0.18% 0.383
WM-MK error -2.52% 0.013

The NMSE change is negligible despite statistical detectability from the large voxel count; the DKI loss reduces MK error. Mean±SD over three runs separately reports run-to-run variability.

[Q2,W2] Direct test of DKI model validity

We directly measure mismatch between the dense ground-truth signal and DKI:

rDKI(y)=∥(I−ΠR)y∥2∥y∥2,r_{\mathrm{DKI}}(y)=\frac{\|(I-\Pi_R)y\|_2}{\|y\|_2},

where $\Pi_R$ projects onto the rank-22 DKI subspace. On UKB at 20% context, the median is 0.052 and p95 is 0.165. Stratifying test voxels by this residual:

DKI residual Q1(lowest) Q2 Q3 Q4(highest)
MK change with LDKIL_{\mathrm{DKI}} -26.5% -8.8% +9.0% +1.3%

The DKI loss helps only in the low-residual half, so component complementarity is conditional on DKI fit. We will replace the bmax⁡b_{\max} explanation with this analysis, report the high-residual failure regime, and narrow the claim.

[Q3,W3] Difference from UPMRI and range–null/data-consistency methods

The projection algebra is shared; our claim concerns the operator and its role. UPMRI/range–null methods use an acquisition operator to enforce measured k-space consistency. MiCo uses the DKI parameter-to-dense-q-space operator HH, whose range is the DKI signal subspace, not the angular-subsampling range.

During training, this projection defines a supervised loss equivalent to the Fisher-metric discrepancy between DKI estimates:

∥x^−x∥H⊤H2=∥ΠR(y^−y)∥22.\|\hat x-x\|_{H^\top H}^{2}=\|\Pi_R(\hat y-y)\|_2^{2}.

The standard flow-matching loss supervises the orthogonal component, and inference is not hard-projected. We will add this operator-level comparison and narrow the novelty claim. A UPMRI numerical comparison is not task-aligned because it addresses parallel-MRI k-space reconstruction with a different operator and domain.

[Q4] Conditioning of the DTI initialization

The context set pools all nonzero-bb measurements and retains all b=0b=0 observations; DTI is fitted once across shells. Thus, the relevant sample size is the total context count, not the per-shell count.

θ^=(AC⊤AC+ΛC)−1AC⊤yC,\hat\theta=(A_C^\top A_C+\Lambda_C)^{-1}A_C^\top y_C,

where AC∈RNC×7A_C\in\mathbb R^{N_C\times7} is the restricted design matrix, yCy_C contains log-signals, and ΛC\Lambda_C is the diagonal Tikhonov regularizer. For gi=(gix,giy,giz)\mathbf g_i=(g_{ix},g_{iy},g_{iz}), row ii is

[−bigix2,−2bigixgiy,−bigiy2,−2bigixgiz,−2bigiygiz,−bigiz2,−1].[-b_ig_{ix}^2,-2b_ig_{ix}g_{iy},-b_ig_{iy}^2,-2b_ig_{ix}g_{iz},-2b_ig_{iy}g_{iz},-b_ig_{iz}^2,-1].

We will correct “ordinary least squares” to “Tikhonov-regularized least squares.”

Cohort Joint NCN_C Median κ(AC)\kappa(A_C) p95 Max Fraction >103>10^3
HCP-YA 45 3.28 4.57 9.07 0
UKB 21 7.24 16.54 130.2 0

The evaluated joint systems are not severely ill-conditioned; this does not establish robustness to substantially sparser, shell-imbalanced, or pathological inputs.

[Q5] Runtime and few-step inference

We benchmarked in-memory HCP-YA batches of 40,960 voxels on one H100 NVL, including transfer, preprocessing, and terminal-signal generation but excluding loading, disk output, and downstream fitting.

Method Steps Throughput Peak memory
MiCo 5 4277 vox/s 3.85 GiB
MiCo 10 2127 vox/s 3.85 GiB
MiCo 15 1415 vox/s 3.85 GiB
MiCo 20 1058 vox/s 3.85 GiB
MiCo 25 846 vox/s 3.85 GiB
DISCUS direct 35,551 vox/s 1.76 GiB

At 20% context, 25→5 steps gives a 5.9× speedup; HCP-YA NMSE/FA/MK change by +4.3%/+1.9%/+2.3%, and UKB by +4.4%/+0.8%/+9.9%. Five steps is a practical fixed-checkpoint setting, not distillation or evidence that fewer steps are universally better. DISCUS remains ~9× faster, so speed is not claimed.

[Q6,W4] Angular evidence and scope

We will move a compact FOD-ACC table to the main results. The corrected summary is that MiCo is best on all three shells at 10% context, best in 5/9 shell-context cells overall, and within one ACC point of the leader in every cell; MAP-MRI and SHORE lead several higher-context cells. This supports competitive, not uniformly superior, angular fidelity.

We will also add the requested companion to Fig. 5 with voxels colored by their ACC in the updated manuscript. The review interface does not permit us to attach that figure or an external link during discussion.

The paper does not evaluate tractography, connectivity, pathology, or spatial context. We will remove language implying those benefits and limit the empirical claim to voxel-wise signal, scalar-microstructure, and FOD reconstruction in healthy HCP-YA and UKB cohorts. Pathology-specific and tractography validation remain future work rather than evidence assumed by the present study.

[Formatting/integrity concern] Hidden PDF text

The footer text was neither authored nor inserted by us, it originates from the conference PDF-processing pipeline.

Reviewer KYG3OpenReview ↗
Rating
5/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
4/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper introduces a physics-informed flow matching framework (MiCo) designed for angular super-resolution (ASR) in diffusion-weighted MRI. The authors address the challenge of reconstructing dense angular signals from sparse acquisitions by leveraging the linearity of the DKI forward model. The framework incorporates two primary innovations, i.e., replacing standard Gaussian noise priors with a closed-form, dense estimate derived from a DTI-based fit, and enforcing microstructural parameter-level consistency via a closed-form projection loss between the predicted and ground-truth signals at the same voxel. MiCo demonstrates competitive performance on the HCP-YA and UK Biobank datasets, particularly in recovering downstream microstructural parameters (e.g., FA, MD, MK) more faithfully than existing ASR baselines, including both the analytical models and the deep learning models.

Strengths and weaknesses

Strength: The idea of integrating DKI forward model constraints directly into the flow matching pipeline is novel and well-motivated. This strategy effectively ensures that signal predictions remain consistent with underlying physical microstructure. The paper’s finding regarding the significant gap between signal-level fidelity (NMSE) and microstructure-level fidelity is interesting. Furthermore, the evaluation is comprehensive, utilizing high-angular-resolution dMRI data from over 5,000 subjects across two public datasets, and the model's performance is rigorously assessed at three distinct levels, i.e., signal reconstruction, microstructural parameter estimation, and FOD reconstruction.

Weaknesses: The weaknesses of this paper mainly lie in the lack of statistical analysis, biased interpretation and insufficient discussion of results. See details in 'Questions'.

Questions

MiCo performs on par with or superior to state-of-the-art deep learning models, particularly in microstructural parameter estimation. However, without formal statistical analysis, it is uncleear whether these performance gains are statistically significant.

The claim that "MiCo achieves a median ACC of 76% on HCP-YA, on par with the strongest generative baselines" is a bit misleading. This figure is derived only from specific test conditions (b=3000 at 30% sparsity), while other methods, e.g. MAP-MRI, demonstrate superior performance at other b-values and sparsity levels as shown in the full results in Appendix E.3.2. It would be good to include a discussion on why other deep learning models underperform relative to MAP-MRI in FOD reconstruction. This is notably different from their performance in signal reconstruction and microstructural parameter estimation, where deep learning models typically perform better.

The paper currently focuses on healthy adult cohorts (HCP-YA and UK Biobank). Future work should include validation on pathological datasets (e.g., stroke, tumors, or neurodegeneration) to test the robustness of the DKI-based consistency loss in non-healthy tissue.

Limitations

Limitations regarding model applicability, clinical generalization, and computational constraints are well-acknowledged by the authors in Appendix A.

Final justification

The authors have addressed my concern related to statistical analysis as well as my other comments. I am therefore happy to increase my score.

Formatting concerns

No.

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for the thoughtful review and for recognizing the novelty of integrating the DKI forward model into flow matching. We agree that the original version needs stronger statistical support and we address it below.

[Q1, W1] Statistical significance of the reported improvements

We agree that formal statistical analysis is needed to determine whether the reported improvements are robust. We added subject-level paired analyses using matched test subjects and identical context masks. Voxel-wise errors are first aggregated within each subject, after which we apply a two-sided paired Wilcoxon signed-rank test across subjects. Mean ±\pm standard deviation across three training seeds is reported separately to characterize run-to-run variability. For MiCo versus DISCUS, the relative changes in downstream error are:

Relative error change, MiCo vs. DISCUS (↓\downarrow) 10% 20% 30%
FA -18.46% -18.20% -19.38%
MD -21.46% -18.23% -17.23%
MK -17.16% -17.67% -17.22%

All nine paired comparisons are significant (all p<0.01p<0.01). This directly supports the downstream improvement over DISCUS. Signal NMSE follows a different pattern: it is 4.48–5.31% higher for MiCo, reinforcing that the main benefit is microstructural fidelity rather than lower signal error.

[Q2, W2, W3] Interpretation of the FOD-ACC results

We agree that the current “76% median ACC” sentence is misleading. Table 6 reports mean ±\pm standard deviation, and the approximately 76% result refers only to the b=3000b=3000, 30%-context condition. We will remove this selected statement and replace it with the complete result.

MiCo achieves the best ACC on all three shells at 10% context, is best in 5 of the 9 shell–context settings overall, and remains within one ACC point of the best-performing method in every setting. MAP-MRI and SHORE remain competitive and outperform MiCo in several lower-shell, higher-context settings. We will move a compact version of the complete FOD-ACC table into the main results and avoid implying uniform superiority.

The different ranking across evaluation levels likely reflects the methods’ distinct inductive biases. MAP-MRI and SHORE use explicit radial–angular basis functions, which can recover higher-order angular structure effectively once sufficient measurements are available. In contrast, the learned methods are optimized primarily for dense signal reconstruction, and MiCo additionally supervises the DKI range-space component; neither objective directly optimizes CSD-derived FOD correlation. Small structured or smoothing errors may therefore have limited influence on signal NMSE or scalar maps while producing larger errors in secondary FOD lobes. We will present this as a plausible interpretation rather than a demonstrated causal mechanism.

[Q3] Validation on pathological populations

We agree that validation on pathological cohorts is necessary before claiming clinical generalization. The current empirical evidence is restricted to healthy-adult HCP-YA and UK Biobank cohorts. As acknowledged in Appendix A, the DKI prior may be less accurate in tissues involving free-water compartments, CSF contamination, severe demyelination, tumors, stroke lesions, or other pathological changes for which the cumulant truncation is a poor approximation.

The DKI loss is auxiliary, and the full signal space remains supervised by the standard flow-matching objective; however, this does not establish robustness when the DKI model is misspecified. Validation on stroke, tumor, and neurodegenerative cohorts remains an important direction for future work.

Reviewer TURzOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
2/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The authors propose an angular super-resolution method for diffusion MRI(dMRI). This is a relevant topic to the NeurIPS audience. The main contributions are:

  1. Utilizing the distributional transport properties of flow matching models to start from a well-defined DTI initialization computed from the sparse observation, instead of starting from Gaussian noise. This leaves the network to model only the residual signal that the tensor initialization leaves underdetermined.
  2. To further root the network in meaningful dMRI physics throughout the flow process, the authors propose a parameter-consistency loss based on the DKI forward model. They show theoretically that when this penalty is measured in the Fisher metric of the linear estimation problem, it collapses to a closed form in signal space, requiring no per-step parameter fitting.
Strengths and weaknesses

Strengths: Overall, I enjoyed reading this paper and thank the authors for their contributions! Individual strengths I would say are: => The arguments that the authors make are well grounded in the physics of dMRI. => The authors explore their design choices and hyper parameters extensively and clearly, providing the readers with a good understanding of caveats to keep in mind when trying to reproduce their results. => The idea to start from a DTI initialization and making the flow model learn to model the residual of this fitting into signal components through a DKI parameter consistency loss is both clever and novel. => The reduction of the Fisher-metric parameter loss to a closed-form signal-space projection was also really nice to read through.

Weaknesses: While the authors extensively explore their design choices throughout the paper, I think the evaluation needs to be strengthened before publication. Mainly I would suggest adding the following(In order of importance):

  1. The authors do not report statistical significance testing anywhere, which makes it hard for the reader to assess whether one method is genuinely better than another. The authors do a good job including many baselines to compare against, but without significance testing on the reported metrics (NMSE, microstructural parameter estimation, ACC), the differences are difficult to interpret.
  2. The authors should reconsider reporting signal NMSE as a main result and move it to the supplementary if possible. Signal fidelity is necessary but not sufficient for this task, and MiCo's NMSE is essentially on par with other learning-based methods and the more meaningful differentiation appears downstream in the microstructural and FOD-level results.
  3. Reporting FA, MD, and MK through the sparse-signal fitting was not fully convincing to me. FA and MD can be estimated reasonably well from a tensor fit alone (which needs only 6 observations), and mean kurtosis, while requiring a DKI fit, is a scalar summary that averages out angular structure. Since the paper's central claim is angular super-resolution, I would like to see metrics that more directly stress the angular component of the diffusion signal.
  4. I would suggest moving ACC on the FODs from the appendix to the main results.
Questions
  1. The model inputs and outputs were not clearly defined in the main text. For example, whether a single model is trained across all shells or one model per shell. I found this in appendix, but I would suggest adding a short description in the main text specifying the model type, its inputs, and its outputs, with a pointer to the appendix for full details. This would make the method much easier to follow on a first read.
  2. For the qualitative assessment, I like the current Figure 5. As a complement, I would suggest showing the same figure with voxels coloured by their ACC, which would give readers a quick spatial snapshot of where FOD agreement is high versus low.
  3. While the advantage of the DKI supervision is explored in the ablation (Table 2), it would be more convincing with significance testing, so the reader can be confident the improvement is not within run-to-run variance.
  4. In addition to the above, I would definitely consider improving my score if the authors report statistical significance on other metrics reported compared to their baselines as well!
Limitations

yes

Final justification

I thank the authors for addressing my comments and recommendations in an adequate way.

Formatting concerns

no issues.

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for the constructive review and helpful suggestions. We agree that the statistical presentation and the emphasis of the evaluation should be improved.

[Q1] Model Interface

MiCo operates on one voxel at a time. Given sparse signal measurements and their q-vectors, it predicts the dense signal at arbitrary target q-vectors. We use one q-conditioned Perceiver-IO model per cohort, shared across all shells rather than training a separate model for each shell. The context tokens encode the observed q-vectors and signals, while the query tokens encode the target q-vectors and the current flow state. We will add this specification to the main text and retain the full architecture in the appendix.

[Q2] Visualization of FOD ACC

We agree that a spatial ACC visualization would complement the current qualitative FOD comparison. In the updated manuscript, we will add a companion panel to Fig. 5 in which voxels are colored by their voxel-wise ACC between the reconstructed and reference FODs, using a consistent color scale across methods. As additional files or links cannot be included at this review stage, we cannot attach the figure here, but it will be included in the revised manuscript.

[Q3, Q4, W1] Statistical support for the main comparison and ablation We added paired statistical analyses using matched test subjects and identical context masks. For each seed, voxel-wise errors are first aggregated within each subject, after which we apply a two-sided paired Wilcoxon signed-rank test across subjects. We report mean ±\pm standard deviation across the three training seeds separately to describe run-to-run variability.

For the complete-method comparison:

Relative reduction in downstream error, MiCo vs. DISCUS (↓\downarrow) 10% 20% 30%
FA -18.46% -18.20% -19.38%
MD -21.46% -18.23% -17.23%
MK -17.16% -17.67% -17.22%

All nine paired comparisons are significant (all p<0.01p<0.01). This directly supports the downstream improvement over DISCUS. Signal NMSE follows a different pattern: it is 4.48–5.31% higher for MiCo, reinforcing that the main benefit is microstructural fidelity rather than lower signal error.

For the component ablation at 20% context:

Effect of adding the DKI loss Relative error change Paired pp
Signal NMSE +0.18% 0.383
WM-MK error -2.52% 0.013

The 0.18% NMSE change is negligible in magnitude, whereas the DKI loss reduces WM-MK error. This is consistent with its intended role: the loss primarily improves the DKI range-space component associated with downstream parameters rather than overall signal NMSE.

[W2] Role of signal NMSE

Signal NMSE should remain as a fidelity check, but not as the headline result. We will compress its presentation and center the main results on the paired FA/MD/MK table and FOD angular evidence. The revised claim is not uniform signal-level superiority: MiCo preserves strong signal fidelity while showing substantially lower downstream error than DISCUS under the evaluated conditions.

[W3, W4] Direct angular evidence and placement of FOD results

We will move a compact FOD-ACC table to the main results and replace the selected “76% median ACC” sentence. Table 6 reports full mean ±\pm standard deviation. The complete conclusion is more informative: MiCo is best on all three shells at 10% context, best in 5/9 shell-context cells overall, and within one ACC point of the leader in every cell; MAP-MRI and SHORE are competitive or better in several lower-shell 20%/30% cells.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.