SLOT-IR: Learning Slot Representations for Infrared Spectral Unmixing
Jingru Gan, Yannah J.U. Melle, Yanqiao Zhu, Daniel Schwalbe-Koda, Wei Wang
NeurIPS 2026
Abstract. Infrared (IR) spectral unmixing recovers individual component spectra from a measured mixture, enabling chemical identification. Existing methods either assume linear superposition of components, which does not hold for liquid-phase mixtures where molecular interactions alter spectral shapes, or use deep networks that encode the whole mixture into one latent vector without separate per-component representations. We introduce SLOT-IR, a slot-based architecture that decomposes mixture spectra into separate per-component embeddings and decodes each independently into a predicted spectrum. A two-stage training procedure first pretrains the encoder on single-molecule spectra, then trains the full unmixing model on mixtures. On a benchmark of liquid-phase infrared spectra computed with molecular dynamics simulations, SLOT-IR outperforms all baselines on both binary and ternary mixture identification. Controlled pretraining experiments suggest that the benefit comes from learning coherent spectra of individual molecules. Pretraining on gas-phase spectra alone performs comparably to pairing gas- and liquid-phase spectra, which points to a scalable source of pretraining data. A post-hoc sparse autoencoder further shows that the per-component embeddings carry information statistically associated with known functional groups.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:44 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper proposes SLOT-IR, a neural network architecture designed for the unmixing of infrared (IR) spectra of liquid-phase molecular mixtures. The authors argue that liquid-phase spectra are non-linear due to intermolecular interactions; to address this, they propose a two-stage training process: first, a supervised translation from gas-phase to liquid-phase spectra, and second, a mixture unmixing task. The architecture employs multi-scale 1D convolutions for tokenization and a Transformer encoder that projects representations into component-specific "slots." These slots are then decoded back into predicted spectra and matched against a reference library. The authors further employ a Sparse Autoencoder (SAE) to analyze the learned slot embeddings, claiming that certain features correlate with chemical functional groups.
Main Strengths
- The use of a two-stage pre-training strategy and a slot-based decomposition approach for spectral unmixing is seen as an interesting technical contribution.
- All reviewers highlighted the post-hoc SAE analysis as a strength, noting that attempting to connect learned latent features back to chemical functional groups adds significant value.
- The inclusion of domain-specific non-deep-learning baselines provides a useful point of comparison.
Main Weaknesses
- A weakness is the ambiguity surrounding the dataset. It is unclear whether the mixture spectra are experimentally measured or synthetically generated from reference spectra. If synthetic, the paper may not actually be solving the non-linear physical problems (hydrogen bonding, peak shifts) that it claims to motivate.
- The method assumes a known number of components and, according to Reviewer Enja, assumes equal proportions. This significantly limits the real-world utility of the model, as abundance estimation is a primary goal of spectral unmixing.
- Reviewers questioned the validity of the gas-to-liquid translation task. Because liquid spectra are heavily dependent on solvent identity and concentration, a simple mapping without conditioning on the environment may lack physical interpretability.
- The deep-learning baselines used for comparison were originally designed for hyperspectral remote sensing, not molecular IR spectroscopy. There is little clarity on how these were adapted or if more domain-relevant neural baselines exist. Furthermore, OOD performance (e.g., drug mixtures) was reported as poor without specific data augmentation, suggesting the model may be memorizing a small chemical space rather than generalizing.
Considerations for authors:
- Explicitly clarify if the training and testing mixtures are experimental or simulated. If simulated, provide the physical model used to account for liquid-phase non-linearities.
- Justify the "fixed" and "equal proportions" assumptions. Provide results showing how the model performs when components are mixed in varying/extreme concentrations.
- Explain exactly how the remote-sensing DL baselines were modified for 1D molecular IR spectra.
- Provide more robust OOD results, specifically addressing whether the model can handle molecules absent from the training set without relying on synthetic augmentation of those specific molecules.
- Clarify the tokenizer's dimensions and provide an ablation study comparing learned positional embeddings against physically-meaningful wavenumber encodings.
Final justification
The discussion and rebuttal substantially resolved the main technical concerns. In particular, the authors clarified how the mixtures are generated, that equal proportions are a property of the current benchmark rather than an architectural assumption, and how the cross-domain baselines were adapted. The added molecule-holdout, pretraining-control, and tokenizer/positional-encoding experiments also provide meaningful additional evidence for the method’s generalization and design choices. The remaining concerns are important limitations and should be stated clearly, but in my view they constrain the scope of the contribution rather than undermine its technical validity. Given the novelty of the formulation, the positive in-scope results, and the useful interpretability analysis, I find the reasons for acceptance outweigh the remaining limitations.
Read meta-review
Meta-review
The paper proposes SLOT-IR, a neural network architecture designed for the unmixing of infrared (IR) spectra of liquid-phase molecular mixtures. The authors argue that liquid-phase spectra are non-linear due to intermolecular interactions; to address this, they propose a two-stage training process: first, a supervised translation from gas-phase to liquid-phase spectra, and second, a mixture unmixing task. The architecture employs multi-scale 1D convolutions for tokenization and a Transformer encoder that projects representations into component-specific "slots." These slots are then decoded back into predicted spectra and matched against a reference library. The authors further employ a Sparse Autoencoder (SAE) to analyze the learned slot embeddings, claiming that certain features correlate with chemical functional groups.
Main Strengths
- The use of a two-stage pre-training strategy and a slot-based decomposition approach for spectral unmixing is seen as an interesting technical contribution.
- All reviewers highlighted the post-hoc SAE analysis as a strength, noting that attempting to connect learned latent features back to chemical functional groups adds significant value.
- The inclusion of domain-specific non-deep-learning baselines provides a useful point of comparison.
Main Weaknesses
- A weakness is the ambiguity surrounding the dataset. It is unclear whether the mixture spectra are experimentally measured or synthetically generated from reference spectra. If synthetic, the paper may not actually be solving the non-linear physical problems (hydrogen bonding, peak shifts) that it claims to motivate.
- The method assumes a known number of components and, according to Reviewer Enja, assumes equal proportions. This significantly limits the real-world utility of the model, as abundance estimation is a primary goal of spectral unmixing.
- Reviewers questioned the validity of the gas-to-liquid translation task. Because liquid spectra are heavily dependent on solvent identity and concentration, a simple mapping without conditioning on the environment may lack physical interpretability.
- The deep-learning baselines used for comparison were originally designed for hyperspectral remote sensing, not molecular IR spectroscopy. There is little clarity on how these were adapted or if more domain-relevant neural baselines exist. Furthermore, OOD performance (e.g., drug mixtures) was reported as poor without specific data augmentation, suggesting the model may be memorizing a small chemical space rather than generalizing.
Considerations for authors:
- Explicitly clarify if the training and testing mixtures are experimental or simulated. If simulated, provide the physical model used to account for liquid-phase non-linearities.
- Justify the "fixed" and "equal proportions" assumptions. Provide results showing how the model performs when components are mixed in varying/extreme concentrations.
- Explain exactly how the remote-sensing DL baselines were modified for 1D molecular IR spectra.
- Provide more robust OOD results, specifically addressing whether the model can handle molecules absent from the training set without relying on synthetic augmentation of those specific molecules.
- Clarify the tokenizer's dimensions and provide an ablation study comparing learned positional embeddings against physically-meaningful wavenumber encodings.
Final justification
The discussion and rebuttal substantially resolved the main technical concerns. In particular, the authors clarified how the mixtures are generated, that equal proportions are a property of the current benchmark rather than an architectural assumption, and how the cross-domain baselines were adapted. The added molecule-holdout, pretraining-control, and tokenizer/positional-encoding experiments also provide meaningful additional evidence for the method’s generalization and design choices. The remaining concerns are important limitations and should be stated clearly, but in my view they constrain the scope of the contribution rather than undermine its technical validity. Given the novelty of the formulation, the positive in-scope results, and the useful interpretability analysis, I find the reasons for acceptance outweigh the remaining limitations.
1 comment
- Rating
- 3/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
A novel method to spectrally unmix nonlinear binary or ternary mixtures, mixed in equal proportions.
Strengths and weaknesses
Strength: Interpretable results Weakness : Limited scope
Questions
How does the model fare in a practical dataset? I suspect that the assumptions of this model fail even for linear mixtures where components are mixed in extreme proportions.
Limitations
The authors clearly mention that the model assumes that the number of components K is known and that all components contribute equally. I would request them to point out instances in real life (not synthetic data) where such a model is necessary.
Formatting concerns
NA
1 comment
Response to Enja
We appreciate your recognition of our contribution. We address your questions below.
Q1 Extreme proportions
We respectfully disagree with the premise that the architecture assumes equal proportions. The slot-based design makes no assumption about component ratios. Each slot reconstructs a component spectrum by attending to a shared mixture encoding via cross-attention, and no concentration signal enters this computation. The equal-proportion setting reflects the available benchmark data, not a model constraint.
We highlight that proportions in IR spectra are not a reliable observable. Peak intensities in IR measurements are affected by instrument calibration, temperature, optical path length, and the specific vibrational modes of each molecule, meaning that concentration cannot be straightforwardly inferred from spectral amplitudes alone. For this reason, practicing IR spectroscopists do not treat concentration extraction as a robust task without system-specific calibration.
Furthermore, our benchmark spectra are produced by molecular dynamics (MD) simulations that capture intermolecular interactions, peak shifts, and non-ideal mixing behavior. Generating variable-proportion data by linearly combining reference spectra would contradict the non-linear mixing behavior that motivates this work. A physically rigorous variable-proportion evaluation requires measured mixtures at controlled ratios with instrument-specific calibration, which is beyond the scope of this work.
Q2 Known K and real-life examples
An assumed value of K is standard practice in analytical chemistry. In synthetic chemistry, in-line reaction monitoring systems can use IR or other techniques to confirm reactant consumption and product formation in real time, where the chemist assumes K from a proposed reaction mechanism. In pharmaceutical quality control, formulation teams verify component identity in preparations with known composition. In forensic analysis, IR spectroscopy is used to identify components of seized liquid samples. In energy applications, K is assumed by the chemist interpreting the results of measurements, from battery electrolytes to petroleum research. Importantly, no automated determination of K is currently possible for complex liquid mixtures. Furthermore, prior to this work, all these workflows related to spectral assignment relied on manual expert interpretation or full access to a library of compounds. SLOT-IR is the first learning-based method to automate this task.
- Rating
- 3/6
- Confidence
- 3/5
- Quality
- 2/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes SLOT-IR, a two-stage slot-based neural architecture for infrared spectral unmixing that first pretrains on gas-to-liquid spectral translation and then predicts per-component liquid spectra from mixture spectra. The model uses separate slot embeddings for each component and evaluates predicted spectra through cosine-based library retrieval on binary and ternary mixture benchmarks. The paper further applies a post-hoc BatchTopK sparse autoencoder to frozen slot embeddings and validates some learned features against functional-group annotations.
Strengths and weaknesses
Strengths
- The paper is clearly written.
- The BatchTopK SAE interpretability analysis is an interesting and valuable attempt to connect learned representations with chemical functional groups.
- Domain-specific non-deep-learning baselines are evaluated in the benchmarking section.
Weaknesses
- The cited deep-learning unmixing baselines, including Gao et al. (2022), Ghosh et al. (2022), and Palsson et al. (2021), were originally developed for hyperspectral remote-sensing unmixing rather than molecular IR spectral unmixing. The paper would benefit from stating this distinction more explicitly and clarifying whether deep learning for molecular IR mixture unmixing has been previously studied. Since the deep baselines are adapted from a different domain, the authors should also provide more detail on how these methods were modified for 1D molecular IR spectra and whether any spectroscopy-specific baselines are available.
- The proposed Stage 1 gas-to-liquid translation task assumes a mapping from a gas-phase spectrum to a liquid-phase spectrum, but this mapping is not unique unless the liquid environment is specified. Solvent identity, concentration, temperature, hydrogen bonding, and other intermolecular interactions can substantially alter IR peak positions, widths, and intensities. The paper motivates the method using these effects, but it does not appear to explicitly model or condition on the liquid environment, which limits the physical interpretability and likely generalization of the learned translation.
- Limited chemical-space coverage. Although the dataset contains thousands of mixture spectra, the number of unique molecules is relatively small: 213 for binary mixtures and 40 for ternary mixtures. This raises concerns about whether the reported performance reflects broad chemical generalization or memorization/interpolation within a limited chemical space. The OOD drug results partly support this concern, as default performance drops sharply on molecules absent from mixture training. The limitation is acknowledged, but given its centrality to the claims, it remains an important weakness.
- The paper is not fully clear about whether the mixture spectra used for training and evaluation are experimentally measured, simulated, or synthetically constructed from reference spectra. If the benchmark relies on simulated spectra or synthetic mixtures, then the evaluation may not fully test the complex nonlinear physical effects that motivate the paper, such as hydrogen bonding, solvent effects, peak shifts, and band broadening. The conclusions about real liquid-phase IR unmixing would be much stronger if the authors clearly documented the data-generation process and validated on experimentally measured mixtures.
- The table headers “Cos” and “Mix” in Table 1 are not self-contained and may be confusing on first reading. Although these metrics are described in Sec. 4.1, the table caption should explicitly define them, e.g., “Cos” as mean matched component cosine similarity and “Mix” as mixture-level R@1 where all components must be correctly identified.
- In the retrieval setting, the candidate set appears to be the 8,550 liquid-phase reference library. But for drug OOD evaluation, it is unclear whether the library includes the 115 drug molecules or is extended for that experiment.
Questions
- Are the binary/ternary mixture spectra experimentally measured liquid-phase mixtures, simulated liquid-phase spectra, or synthetically generated mixtures from reference spectra? Please clarify the data-generation process for every dataset used in training and evaluation.
- If any test mixtures are simulated or generated by mixing reference spectra, what physical model is used to account for liquid-phase nonlinearities such as hydrogen bonding, solvent effects, peak shifts, broadening, and concentration dependence?
- What exactly does “liquid-phase spectrum” mean in the gas-to-liquid translation task? Is it a neat liquid, a solution in a specified solvent, a solvent-subtracted measurement, or a simulation? Is solvent identity or liquid environment controlled or modeled?
- Since Gao et al. 2022, Ghosh et al. 2022, and Palsson et al. 2021 are originally hyperspectral remote-sensing unmixing methods, how were they adapted to 1D molecular IR spectra, and are there any prior molecular spectroscopy baselines or simpler neural baselines that should be included for a more domain-relevant comparison?
(A side note, the authors don't have to respond to this) I am open to reconsidering my assessment if the authors can clarify that the benchmark consists of physically realistic, experimentally measured mixture spectra with adequate chemical diversity. However, if my current understanding is correct—that the dataset is largely simulated or synthetically constructed and covers only a small number of unique molecules—then I believe this remains a central weakness, because the evaluation may not sufficiently test the nonlinear liquid-phase effects that motivate the method.
Limitations
yes
Final justification
I keep my original score of borderline reject, as I believe my previous concerns about baselines and data are not fully addressed. I still hold the following suggestions I made during the Author-Reviewer discussion period:
- Apart from those remote-sensing baselines, are there any molecular machine learning models that can be directly adopted to tackle this task?
- It seems that most reviewers agree that more work is needed on the dataset. Since you can simulate them, a more comprehensive dataset with a larger chemical space and non-equal proportions would strengthen the model. I am not confident that an experimentalist would be convinced to use this model if they realized those limitations.
Formatting concerns
No formatting concerns have been noticed.
5 comments
Response to H9JH (1/3)
We appreciate the insightful comments and questions. We address each below.
W1 & Q4: The DL baselines are from remote sensing, not molecular IR
We agree and will state this more explicitly. To our knowledge, no prior deep-learning method exists for molecular liquid-phase IR unmixing, so we adapted the closest hyperspectral unmixing methods as baselines. Establishing this benchmark is also one of our key contributions.
For each baseline model, 2D spatial operations are replaced with 1D spectral equivalents while all core architectural principles are preserved. For CNNAEU (Palsson et al., 2021), we replaced the 2D encoder-decoder with a 1D architecture, resizing layers proportionally while preserving the autoencoder structure. For CyCU-Net (Gao et al., 2022), we replaced 2D convolutions with 1D equivalents while preserving the cycle-consistency loss. For DeepTrans-HSU (Ghosh et al., 2022), we replaced the spatial tokenizer with a 1D spectral tokenizer while preserving the transformer backbone. We will add this to the revised manuscript.
W2 & Q3: The gas-to-liquid mapping is not unique
We agree that the gas-to-liquid mapping, as stated by the reviewer, is physically non-unique in general. It is important to highlight that all liquid-phase spectra are pure-phase components: each molecule is the sole species in its liquid simulation, so intermolecular interactions are due to the single species interacting with copies of itself. No solvents are involved. If solvents were added, they would be called mixtures in our formalism. While pure-phase molecular liquids may seem irrelevant for drug discovery, the majority of materials-related applications (battery electrolytes, ionic liquids, fuels, food industry, geological samples, environmental studies) require this formalism of distinguishing between pure- and mixture-phase spectra.
In our setting, all liquid-phase spectra are assessed with ns-long MD simulations with hundreds of atoms, thus providing a well-behaved environment that captures the physics of intermolecular interactions. This is true both for pure- and mixture-phase simulations, allowing the data to be generated for homogeneous and heterogeneous systems. Thus, condensed-phase effects such as peak shifts and band broadening, are present in the spectra and are what the model learns to handle.
The comment raises an intriguing question about whether the downstream unmixing actually relies on the gas-to-liquid cross-domain transfer. To test this, we conducted an additional controlled experiment that isolates the contribution of the Stage 1 training objective. We train SLOT-IR end-to-end with four Stage 1 variations: (1) Gas-to-Liquid translation (our proposed method), (2) Gas-to-Gas autoencoding, (3) Liquid-to-Liquid autoencoding, and (4) Shuffled gas-liquid pairs as a controlled contrast. We exclude all drug molecules from both Stage 1 and Stage 2 training to ensure performance differences reflect only the Stage 1 objective. Only the Stage 1 training objective changes, while Stage 2 kept identical throughout.
Table R3. Stage 1 objective control experiment
| Stage 1 Objective | Component R@1 (%) | Mixture R@1 (%) |
|---|---|---|
| Gas-to-Liquid translation | 81.6 ± 1.7 | 66.4 ± 3.0 |
| Gas-to-Gas autoencoder | 81.6 ± 1.8 | 66.4 ± 3.1 |
| Liquid-to-Liquid autoencoder | 80.5 ± 2.8 | 64.3 ± 4.8 |
| Shuffled (incoherent pairs) | 29.3 ± 23.7 | 12.7 ± 10.8 |
Our key finding is that the model achieves comparable performance whether Stage 1 reconstructs a gas spectrum, a liquid spectrum, or translates between domains. The results suggest that downstream unmixing does not uniquely depend on the gas-to-liquid domain transfer or condition on the liquid environment.
The shuffled condition breaks molecular correspondence between input and target while keeping the same data. The performance collapse with high variance shows that the benefit of Stage 1 comes from learning coherent spectral reconstructions for individual molecular identities, not from exposure to more data.
These results directly address the reviewer’s concern about the gas-to-liquid task. First, our data is not produced with the assumption of a solvent, but with pure- and mixture-phase liquids separately, as would be of relevance to many chemical applications. Second, our proposed model does not depend on that mapping, so its non-uniqueness has no effect on performance. More importantly, these findings enable future scaling to larger chemical spaces. Experimental collection of liquid-phase IR spectra is extremely expensive and limits the accessible chemical space for training, while gas-phase IR spectra are available at large scale from public databases. Future models can be pretrained on orders of magnitude more molecular data. We will incorporate this finding and discussion into the revised manuscript.
Response to H9JH (2/3)
W3: The chemical diversity is limited
We agree that the number of unique molecules is limited by the available simulated data. However, we emphasize two points for this constraint: first, the number of possible mixtures scales combinatorially with molecule count (i.e., N choose K problem). Second, each simulation is performed with expensive molecular dynamics (MD) simulation that explicitly treats the intermolecular interactions and anharmonicities in liquid-phase simulations. These simulations require ns-long simulations with hundreds of atoms, corresponding to a cost of about 15 GPU-min per trajectory to produce. Thus, our dataset containing about 44k simulations actually corresponds to a substantial computational cost. No similar dataset exists in the literature, as liquid-phase simulations are both costly and challenging to perform. We believe further work can expand on this dataset to achieve broader coverage of the chemical space. Nevertheless, within this novel dataset, we already show evidence from three aspects to support that the model learns generalizable spectral decomposition rather than memorizing specific molecule pairs.
1. Molecule-level cross-validation. In 5-fold cross-validation (paper Table 4), molecules are split so that test molecules never appear in Stage 2 training. The model achieves 85.6 ± 1.0% binary R@1 and 94.8 ± 0.4% ternary R@1, maintaining performance on held-out molecules it was never trained to unmix.
2. Molecule holdout. We hold out 50 molecules from Stage 2 mixture training (46 of which appear in test mixtures) and evaluate per-molecule decomposition quality. These held-out molecules appear in Stage 1 pretraining but never in any mixture training.
Table R4. Molecule holdout experiment.
| Molecule Category | Definition | N | Cosine Similarity | Component R@1 (%) |
|---|---|---|---|---|
| S12 (in-distribution) | In Stage 1 and Stage 2 training | 163 | 0.965 ± 0.028 | 72.4 |
| S1 (held out) | In Stage 1 only, never in mixture training | 46 | 0.923 ± 0.130 | 52.4 |
| U (drugs) | Never seen in any training | 115 | 0.736 ± 0.109 | 1.8 |
Held-out molecules (S1) achieve cosine similarity 0.923 between predicted and ground-truth component spectra, demonstrating that the model can decompose molecules it was never trained to unmix. In addition, we compared the R@1 of S1 molecules when they are paired with in-distribution (S12) or other held-out molecules (S1), and observed no significant difference, confirming that each slot decomposes independently.
3. Gas-to-Gas autoencoder control. The Gas-to-Gas autoencoder pretraining (detailed in W2 above) achieves identical downstream performance without the encoder ever observing liquid-phase spectra during Stage 1. A model that memorizes liquid-phase patterns cannot explain equivalent performance from an encoder that has never seen them.
Regarding drug OOD. The drug molecules use entirely different molecular scaffolds from the training set and were never seen in any training stage. This setting tests a fundamentally different capability from spectral unmixing. Unmixing decomposes a mixture into constituent spectra, while identification requires having seen related chemistry. The baseline expectation for drug OOD is effectively zero (random chance from 8,550 candidates), and is an impossible task for any of the baseline methods in the paper. The task of unmixing novel chemistry that was never observed during training is genuinely hard and unsolved. We have demonstrated in the paper that expanding the training chemical space via augmentation already improves drug OOD performance substantially (Sec. 4.4), and the gas-phase autoencoder finding (W2) provides a clear scaling path: future models can pretrain on hundreds of thousands of gas-phase spectra from public databases, dramatically expanding the accessible chemical space without requiring expensive liquid-phase measurements. Therefore, the drug OOD task is not simply a generalization test, but a demonstration of how SLOT-IR can be scaled toward larger systems.
Response to H9JH (3/3)
W4 & Q1 & Q2: The data generation process is unclear; What physical model used
We thank the reviewer for raising this concern. We want to clarify that all mixture spectra and liquid-phase reference spectra are obtained using molecular dynamics (MD) simulations for both gas- and liquid-phases. These simulations are performed with ns-long simulations of up to 100 molecules per task, which explicitly treat intermolecular interactions, solvation effects, hydrogen bonding, limitations of rotational and translational degrees of freedom, and anharmonicities that would be otherwise impossible to obtain. As discussed above, these all-atom MD simulations are performed for individual molecules, as well as molecular pairs and triplets. Therefore, mixture-phase spectra are not synthetic linear combinations, but challenging spectra where relative peak intensities are not straightforward, and several non-linearities are present: peak shifts, peak broadening, convolved peaks, obscured fingerprint regions, and more. Gas-phase spectra used in Stage 1 are also computed using MD simulations, thus capturing anharmonicities and rotational effects that are not accessible at local quasi-harmonic approximations. We will add the data generation and simulation protocol details to the revision, including the force field information, scaling, physical effects, and more.
W5: Table headers are unclear
Thanks for pointing this out. We will expand the abbreviations in table captions in the revision. Your understanding of "Cos" and "Mix" is accurate.
W6: Drug OOD library composition is unclear
The reference library includes all 115 drug molecules to allow molecule retrieval after unmixing, so the candidate library contains 8,550 molecules in total. We will clarify this in the revision.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper introduces SLOT-IR, a neural method for infrared spectral unmixing of liquid-phase molecular mixtures. The input is a normalized 1D IR spectrum, tokenized by multi-scale learned 1D convolutions and processed by a Transformer encoder. Training has two stages: first, supervised gas-to-liquid spectral translation using paired single-molecule spectra; second, mixture unmixing, where the encoder output is projected into K component-specific slot embeddings and each slot is decoded into a predicted component spectrum. Components are matched with ground truth using Hungarian assignment, then identified by cosine similarity against a liquid-phase reference library. Experiments on simulated annotated IR mixtures report higher binary and ternary component identification accuracy than NNLS, SUnSAL, matrix factorization, and deep-learning baselines. An ablation shows large performance loss without Stage 1 pretraining. OOD drug-mixture performance is poor unless drug data or synthetic drug mixtures are added. Post-hoc BatchTopK SAE analysis suggests some slot features correlate with SMARTS-derived functional groups.
Strengths and weaknesses
Paper is interesting. The Stage 1 pre-training seems to be of significant benefit, and seems like a good approach to deal with data scarcity.
The SAE analysis is interesting.
Overall, the paper as written was limited in scope and significance. I think it could benefit significantly from addressing some common real-world issues, such as unknown components, unknown number of components. The filters and convolutions also seemed to be somewhat opaque. What are they actually learning? Why does the positional encoding need to be learned, since it is just the wavenumber, isn’t it? What if the filters were fixed smoothers?
Overall, I also found the paper somewhat unclear in a number of places.
Questions
Here are focused author questions/suggestions you could consider raising:
-
Clarify task scope.
The method assumes knownK, does not estimate abundances, and uses library matching for final identities. Could the authors state more explicitly that this is fixed-Kcomponent identification/spectrum prediction rather than full quantitative unmixing? -
Explain the tokenizer.
How many Conv1D filters/channels are used per branch? Are the three branches each 512-dimensional? Are convolution outputs concatenated by scale, and how are positional embeddings assigned to multi-scale tokens? -
Ablate positional/tokenization choices.
Since IR wavenumber location is physically meaningful, compare learned positional embeddings with sinusoidal or physically parameterized wavenumber encodings. Also ablate the{10,25,50}convolution branches to show the value of multi-scale tokenization. -
Disentangle pretraining vs architecture.
Stage 1 gives a very large gain. Would simpler pretraining tasks, such as liquid-spectrum autoencoding, denoising, or single-molecule spectrum prediction, give similar improvements? -
Stress-test generalization.
The OOD drug result is weak without augmentation. Additional experiments with held-out molecule families, variable concentrations, wrongK, or components absent from the reference library would clarify the method’s practical limits.
Limitations
The limitations have been mentioned elsewhere, but pertain to real-world scenarios such as unknown components, unknown number of components (k), etc. Providing some guidance on these could significantly strengthen the paper.
Final justification
I have read the rebuttal from the authors. While I appreciate the additional information, and it does move my evaluation up slightly, I feel that it is not enough to move it to a solid 5 (accept). I will stay with 4 (borderline accept).
Formatting concerns
None.
2 comments
Response to YiPa (1/2)
We appreciate the reviewer's recognition of our proposed Stage 1 pretraining approach and the SAE analysis. We address the concerns on scope, clarity, and generalization below.
Q1: Clarify task scope
We agree that the task is fixed-K blind component identification. Given a mixture spectrum and the number of components K, the model identifies the top-K candidate spectra without knowledge of the individual molecules. This is much more challenging than existing methods, where libraries of known spectra are required to perform the unmixing task. We will explicitly clarify this task scope in the revision. We emphasize that this formulation does not have a direct counterpart, as learning operations on spectra is more similar to human-based deduction than algorithmic or generative methods.
Q2: Explain the tokenizer
The tokenizer uses three parallel Conv1D branches with kernel sizes 10, 25, and 50. Each branch maps the raw spectrum (length 1250) to 512-dimensional feature maps. Average pooling with stride equal to the kernel width produces 125, 50, and 25 tokens from the three branches respectively. These are concatenated along the sequence dimension to form a single 200-token sequence. One learned positional embedding per position is added after concatenation.
Q3: Ablate positional/tokenization choices.
We provide both ablations below, each isolating a single design factor with all other variables held fixed.
1. Multi-scale tokenization ablation.
For each configuration, we remove one branch from the tokenizer and retrain the entire pipeline end-to-end from scratch.
Table R1. Multi-scale tokenizer branch ablation.
| Configuration | Component R@1 (%) | Mixture R@1 (%) |
|---|---|---|
| Full [10, 25, 50] | 88.2 ± 0.3 | 77.9 ± 0.5 |
| Drop w=10, keep [25, 50] | 81.2 ± 0.8 | 65.4 ± 1.2 |
| Drop w=25, keep [10, 50] | 85.3 ± 0.8 | 72.3 ± 1.3 |
| Drop w=50, keep [10, 25] | 76.4 ± 5.5 | 57.9 ± 8.3 |
The results confirm that all three branches contribute to the final performance. The broad-scale kernel (w=50) captures overall molecular band envelopes and is most critical. The finer-scale kernels resolve sharp functional-group peaks. The multi-scale tokenization design is necessary and no two-branch subset is sufficient.
2. Positional encoding ablation.
We replace learned positional encoding with standard sinusoidal positional encoding (Vaswani et al., 2017) and retrain end-to-end.
Table R2. Positional encoding ablation.
| Positional Encoding Type | Component R@1 (%) | Mixture R@1 (%) |
|---|---|---|
| Learned positional encoding | 88.2 ± 0.3 | 77.9 ± 0.5 |
| Sinusoidal positional encoding | 70.5 ± 0.6 | 48.8 ± 0.8 |
The learned positional encoding outperforms sinusoidal, with gap in both Stage 1 and Stage 2. Because our multi-scale tokenizer concatenates tokens from three branches, token index no longer maps to wavenumber, and learned positional encoding is needed to distinguish branch identity and within-branch spectral position. Though the claim that "wavenumber location is physically meaningful" is valid for a single-branch tokenizer, our multi-scale design requires learned positional encoding.
Response to YiPa (2/2)
Q4: Disentangle pretraining vs architecture.
To isolate the contribution of Stage 1, we performed additional controlled experiments varying the Stage 1 objective. Please see our reply to reviewer H9JH W2 for the full table and discussion. Single-phase autoencoding for gas-phase or liquid-phase also achieves comparable downstream performance to the proposed Gas-to-Liquid translation. The pretraining benefit comes from learning coherent spectral reconstruction, not from the specific cross-domain objective. Particularly, the gas-phase autoencoding is promising for future scaling since gas-phase spectra are readily available from experiments at large scale. We will include the discussion in the revision.
Q5: Stress-test generalization.
Thank you for suggesting the stress tests. Below we address each separately.
Held-out molecules. Please see the response to reviewer H9JH W3 for full results. Held-out molecules achieve 52.4% Component R@1 without any mixture training, demonstrating generalizable spectral decomposition. The drug OOD molecules represent an extreme case where entirely unseen molecular scaffolds must be both decomposed and identified, and the weak results reflect the difficulty of identifying chemistry never observed during training. Importantly, the drug OOD molecules were constructed to be the most challenging dataset, as confounding factors such as isomers or similar functional group pairs (e.g., Br and I, methyl and ethyl) were introduced to complicate this task (Melle et al., 2026). Augmentation already improves this substantially (paper Table 3).
Variable concentrations. This is an important point. Our proposed architecture is proportion-agnostic (see AC point 2), so in principle, it can identify IR spectra regardless of proportions. However, it is important to highlight that, extracting proportion information from IR spectra is unreliable in experimental settings, thus rarely trustworthy. Relative peak intensities do not map directly to the molar ratios of the mixture, as measurements depend on everything from temperature or calibration of the spectrometer. The vibrational excitations leading to IR spectra depend on many other factors beyond molecular ratios. Therefore, IR spectroscopy experts would not consider the "variable concentration" task to be robust across instruments or systems. A rigorous variable-proportion evaluation requires system- and instrument-dependent calibration across measured mixtures at varying ratios, which is beyond the scope of this work.
Wrong K. SLOT-IR requires K as input, as do all baselines in the paper. In analytical chemistry practice, K is typically known or assumed from the experimental design. Testing wrong K does not bring additional information, as researchers can sweep K and select the value where all slots yield high-confidence library matches. This is post-processing, not an architectural limitation, and no method currently solves the joint K-estimation and unmixing problem for complex liquid mixtures.
Components absent from the reference library. Library matching is an evaluation-time operation, not an architectural component. If a molecule is absent from the library, it cannot be identified regardless of decomposition quality. This is the key innovation from our method: while decomposition methods require a library to do the identification, our method tackles the "unmixing" separately, allowing spectral signatures to be inferred without knowledge of the molecule or library per se.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Response to Area Chair and All Reviewers
We thank all reviewers for their constructive feedback. We address the AC's requests below, with full details in the corresponding responses to reviewers. All new experiments follow the manuscript's evaluation protocol with 5 random seeds (mean ± std).
Data Generation (H9JH W4): All mixture spectra and liquid-phase spectra are simulated using molecular dynamics (MD) simulations that include non-linearities and intermolecular interactions that lead to peak shifts, non-ideal mixing behavior, and strong deviations from synthetic linear combinations. Gas-phase spectra (only in Stage 1) are also computed with MD, which allows us to compute spectra considering anharmonicities that would not be otherwise accessible.
Fixed proportions (YiPa Q5, Enja Q1): The model has no equal-proportion assumption, because each slot reconstructs a component spectrum via cross-attention without any concentration input. The equal-proportion benchmark is limited by the available data, not the model. A variable-proportion evaluation requires measured mixtures at varying ratios and is beyond the scope of this work.
DL baseline adaptations (H9JH W1): The baselines (CNNAEU, CyCU-Net, DeepTrans-HSU) were adapted from 2D spatial hyperspectral to 1D spectral by replacing 2D convolutions with 1D equivalents. Core architectural principles (autoencoder structure, cycle-consistency loss, transformer backbone) are preserved in each case.
Robust OOD without augmentation (H9JH W3): We conduct a new molecule holdout experiment that holds out 50 molecules from Stage 2 training. For held-out molecules seen only in Stage 1 pretraining, the model achieves cosine similarity 0.923 and Component R@1 52.4%, demonstrating that spectral decomposition generalizes beyond the mixture training set without augmentation.
Tokenizer and positional encoding ablation (YiPa Q3): We conduct additional ablation experiments on multi-scale tokenizer and positional encoding. Results show that all three scales contribute uniquely to the overall performance, and the learned positional encoding outperforms sinusoidal positional encoding.