VolCo: Volumetric Contact for High-Fidelity Human Grasp Generation
Zhuo Chen, Yihua Cheng, Ales Leonardis, Hyung Jin Chang
NeurIPS 2026
TL;DR. A new type of 3D volume-based contact representation to address realistic grasp generation.
Abstract. Accurate contact modeling is fundamental to understanding hand–object interaction, yet existing contact representations are typically restricted to object surfaces and rely on hand‑crafted rules to recover contact details, leading to severe penetrations and implausible results. To better exploit the rich detail in motion‑capture data, we introduce Volumetric Contact (VolCo), a representation that expands surface points to a set of 3D volumetric grids. VolCo encodes 3D contact that allows precise hand part recovery, and is organized in an inherent hierarchy: local contact details within each volume and global hand geometry across all volumes. Our framework, VolCoDiff, employs two modules to capture local and global features following this hierarchy. For local contact details, we use a 3D variational autoencoder to model the possible hand configurations conditioned on the local object signed distance field (SDF). For global hand geometry, we design a prior‑guided diffusion model that learns the distribution of compressed latent features aggregated from the volumetric grids. We evaluate our method on two benchmark datasets and demonstrate state‑of‑the‑art performance in penetration and stability, indicating the capability to generate tight grasps with much less severe penetrations.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:45 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper received one borderline reject, and two borderline accept, making it a borderline case. AC reads the paper and review. From the positive side, reviewers agree that this work presents empirically supported volumetric contact modeling that fixes critical gradient issues in prior optimization methods, and introduces the compelling VolCoDiff framework which jointly learns voxel contact and hand pose latents via a unified diffusion model instead of conventional two-stage pipelines. The voxel-based VolCo representation is not restricted to grasp synthesis and can generalize to other fine-grained contact tasks including tactile sensing and robotic manipulation, acting as a versatile intermediate representation separate from downstream workflows. The weakness includes experiments, especially evaluations related to Intersection Volume (IV) metric. Considering the weakness could be addressed in the rebuttal, AC give initial positive feedback, and has intention to accept, if the rebuttal can address reviewers' concerns.
Final justification
After the rebuttal, all reviewers became positive and were leaning toward acceptance. AC agrees to accept.
Read meta-review
Meta-review
This paper received one borderline reject, and two borderline accept, making it a borderline case. AC reads the paper and review. From the positive side, reviewers agree that this work presents empirically supported volumetric contact modeling that fixes critical gradient issues in prior optimization methods, and introduces the compelling VolCoDiff framework which jointly learns voxel contact and hand pose latents via a unified diffusion model instead of conventional two-stage pipelines. The voxel-based VolCo representation is not restricted to grasp synthesis and can generalize to other fine-grained contact tasks including tactile sensing and robotic manipulation, acting as a versatile intermediate representation separate from downstream workflows. The weakness includes experiments, especially evaluations related to Intersection Volume (IV) metric. Considering the weakness could be addressed in the rebuttal, AC give initial positive feedback, and has intention to accept, if the rebuttal can address reviewers' concerns.
Final justification
After the rebuttal, all reviewers became positive and were leaning toward acceptance. AC agrees to accept.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes a method for high-fidelity hand-object interaction (HOI) generation based on a novel contact representation, VolCo. VolCo is a hierarchical contact representation - with local contact details within each volume and global hand geometry across all volumes - enabling more fine-grained HOI modeling than conventional object-surface contact map-based representations. Based on VolCo, the paper introduces VolCoDiff, a latent diffusion model that models the plausible distribution of grasps. In the experiments, the proposed framework achieves state-of-the-art performance on grasp generation and contact-driven pose reconstruction compared to existing baselines.
Strengths and weaknesses
Strengths
- Strong empirical results
The proposed framework yields strong empirical results on grasp generation and contact-driven pose reconstruction compared to existing state-of-the-art methods.
- Reasonable motivation for the contact representation
The motivation for the volume-based contact representation is reasonable, especially regarding the non-robustness of prior object surface-based contact representations during test-time adaptation based on nearest-neighbor queries.
- Good paper presentation
Overall, the paper is easy to read, and the exposition is mostly clear.
- Comprehensive ablation study
The ablation study is comprehensively reported and helpful for understanding the effectiveness of each proposed module.
Weaknesses
- Questionable results on the Intersection Volume (IV) metric
While the experimental results are mostly strong, the suboptimal performance on the Intersection Volume (IV) metric is questionable, especially since the motivation for adopting a volume-based contact representation is to alleviate penetration. Further explanation would be helpful.
- Missing analysis with respect to volume resolution
Since the proposed contact representation is volume-based, I suspect there could be a potentially significant trade-off between result quality and efficiency depending on the volume resolution. Further analysis related to this would be informative.
Questions
-
Could you provide further explanation for why the proposed framework achieves suboptimal results on the Intersection Volume (IV) metric despite adopting a volume-based contact representation?
-
Could you provide additional analysis with respect to volume resolution, especially regarding the potential trade-off between result quality and efficiency?
-
From the ablation study, it seems that pose initialization significantly influences fitting quality. Could you provide more analysis on the framework’s robustness to the quality of the initialized pose?
Limitations
Yes.
Final justification
The rebuttal addressed most of my concerns. While minor concerns about the suboptimal IV results and sensitivity to pose initialization remain, I acknowledge the paper’s strengths noted in my review and therefore maintain my borderline accept rating.
Formatting concerns
No.
5 comments
Author Response to Concern 2 & 3: Volume resolution and inintialization
Concern 2: Analysis w.r.t. volume resolution. Trade-off between resolution & efficiency.
Weakness: Missing analysis with respect to volume resolution. Question: Could you provide additional analysis with respect to volume resolution, especially regarding the potential trade-off between result quality and efficiency?
Thanks for the suggestion. We constructed a smaller scale model (VolCoDiff-S) with 64 volumes of 4^3 resolution. The latent dimension for each volume is also decreased from 128 to 64 to match the scale. We find an obvious decrease in Peak Memory and Parameter count, and the FLOPs decreased by half with the number of volumes, but the inference time does not change much. This is because the volumes are compressed to 128-dim (64-dim for VolCoDiff-S) latent vectors by VolumeVAE, so the resolution has little impact on the computational complexity during inference. More points make optimization more complicated, but judging from the optimization time, the influence is not obvious due to GPU-parallelism. The performance, however, gets consistent promotion in all criteria with the increase of volume resolution.
| Inference time (s) | Optimization time (s) | Total time (s) | Peak Memory | Params | TFLOPs | SD (cm) | PD (cm) | IV (cm$^3$) | |
|---|---|---|---|---|---|---|---|---|---|
| VolCoDiff-S () | 5.48 | 4.89 | 10.37 | 243.5M | 58.6M | 1.02 | 0.67 | 0.32 | 6.05 |
| VolCoDiff () | 5.28 | 5.39 | 10.67 | 358.1M | 74.04M | 2.01 | 0.52 | 0.27 | 3.78 |
Thus, higher volume resolution achieves better performance at an acceptable price. Only when the memory or parameter count becomes the bottleneck will VolCoDiff-S become the better choice. This version of model is added to the manuscript manuscript.
Concern 3: Robustness to the quality of pose initialization.
Question: From the ablation study, it seems that pose initialization significantly influences fitting quality. Could you provide more analysis on the framework’s robustness to the quality of the initialized pose?
Thanks for the suggestion. We have conducted the experiments by adding random noise to the predicted root pose of the grasp, and do the same optimization to see how the performance deteriorates. The results are reported below. The noise level refers to the sigma of Gaussian noise added to the predicted initial hand pose. the unit for noise added to translation and pose are different: dm for translation and radian for pose. So at 0.5 noise level, the noise added to hand wrist translation has a std of 5cm on each dimension, and the noise added to pose has a std of 0.5 rad (~28.6°) on each axis in axis-angle representation.
| Noise level | SD (cm) | PD (cm) | IV (cm$^3$) |
|---|---|---|---|
| 0 | 0.52 | 0.27 | 3.78 |
| 0.01 | 0.85 | 0.27 | 3.74 |
| 0.1 | 0.80 | 0.28 | 3.87 |
| 0.2 | 0.78 | 0.32 | 4.32 |
| 0.5 | 0.82 | 0.47 | 8.35 |
The table gives us two hints: stability measure (SD) is sensitive to noise. a little noise will cause the result to deteriorate. Penetrations are more robust, but will obviously deteriorate at 0.5 noise level. So our method can resist noise within 0.2 level (2cm in translation, ~11.5° in pose) and make visually plausible grasps, but to achieve a stable grasp, a good initialization is very important.
Follow-up on Our Response to Reviewer 3wj7
Dear Reviewer 3wj7,
Thank you again for your time and constructive feedback. In our rebuttal we provide detailed clarifications and additional results addressing each of your concerns, including IV analysis, resolution-efficiency trade-off, and robustness to initialization.
As the discussion period draws close to end, we would be grateful for any further questions or remaining concerns, and are happy to provide additional clarifications.
Best regards,
Submission18575 Authors
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
To tackle hand-object contact, this paper introduces Volumetric Contact (VolCo), a representation that expands surface points to a set of 3D volumetric grids. VolCo encodes 3D contact in an inherent hierarchy, with local contact details within each volume and global hand geometry across all volumes. A framework, VolCoDiff, is proposed to capture local and global features: a 3D VAE is used to model hand-configuration conditioned on local object SDF, and a prior-guided diffusion learns the distribution of latent features of global hand geometry. Results on two benchmarks are shown for contact and grasp generation.
Strengths and weaknesses
Strengths:
S1: Using volumetric representation in contact representation is well motivated. And in the framework, the design of using volumetric in the feature extraction and diffusion parts is reasonable.
S2: Results on hand reconstruction from the GT contact show that the proposed representation and method can preserve valid information.
Weakness:
For grasp synthesis results, why does Intersection Volume (IV) increase compared with all baselines, while SD and PD decrease? That happened on both datasets. Does it from evaluation drawback or the proposed method tend to produce better SD / PD while the real contacts are not better?
Questions
From the same object, the grasp can be in different hand poses/geometries. How do you evaluate such uncertainty? In your evaluation, only one grasp is produced and evaluated?
From Table 4, adding prior guidance significantly increased IV. Why does this happen?
Limitations
Compared with the point-contact baseline, this volumetric-based method requires significantly more parameters and memory, while the performance shows a little improvement on SD and PD, while get the worst IV among all.
How does the performance hold up when extending to unseen object categories?
Final justification
I thank the authors for their justification and additional results. The rebuttal addressed most of my questions. I have updated my score to BA.
Formatting concerns
Figure 2: In the figure, should there be “Volume Decoder” and “Hand Decoder” to produce local hand config and hand mesh?
3 comments
Author Response to Concern 1: Analysis on SD / PD & IV
We thank the reviewer for the valuable feedback. We are encouraged that the reviewer finds the volumetric representation well-motivated and information preserving. Regarding the concerns, we address them one by one as follows:
Concern 1: Why the method produces lower SD / PD but higher IV?
Weakness: For grasp synthesis results, why does Intersection Volume (IV) increase compared with all baselines, while SD and PD decrease? That happened on both datasets.
Limitation: Compared with the point-contact baseline, this volumetric-based method requires significantly more parameters and memory, while the performance shows a little improvement on SD and PD, while get the worst IV among all.
We thank the reviewer for this comment. Our work proposes VolCo, a novel volumetric contact representation for accurate contact modeling and the synthesis of plausible grasps. However, we respectfully note that evaluating grasp plausibility is non-trivial. For example, greater grasp stability often comes at the cost of increased penetration. Conversely, a method can trivially achieve zero penetration by generating grasps that do not reach the object, which would result in a zero grasp success rate. This inherent trade-off makes it difficult for a method to perform well across all evaluation metrics.
Trade-off between IV and PD: We use interaction volume (IV) and penetration depth (PD) to evaluate the generated grasps. Our method achieves a lower PD but a relatively higher IV because it favors stable grasps characterized by broad yet shallow penetration. As shown in the qualitative results in Fig. 5 of the manuscript, our method generates a stable grasp in which the palm wraps around the object, whereas the compared method generates a grasp in which the fingers penetrate the object model. Consequently, our method produces a larger contact area and a higher IV while maintaining a lower PD. In contrast, because the compared method establishes contact primarily through deeply penetrating fingers, it produces a higher PD but a lower IV. The contact area (CA) metric further supports our claim, as our method achieves a larger CA. For ease of reference, we summarize below the CA values of the compared methods reported in our manuscript.
Metric IV (1 mm$^3$): To further validate our claim, we evaluate a new metric IV (1 mm$^3$) in this response. The IV reported in the paper voxelizes the object with a grid size of 5 mm, and only the voxels crossed by the object surface are retained. While IV (5 mm$^3$) works well for a rough estimation of penetration, it has two limitations at a finer level: thin objects with thickness smaller than 5 mm may be overestimated, and deep penetrations larger than 5 mm may not be fully counted, since only voxels around the object surface are considered.
IV (1 mm$^3$) is computed in a similar way to IV (5 mm$^3$), but with a finer grid size of 1 mm. In addition, the volume inside the object is also considered, which addresses the two limitations mentioned above [1]. We evaluate IV (1 mm$^3$) on the GRAB dataset and summarize the results below.
| GRAB | HO3D | |||||||
|---|---|---|---|---|---|---|---|---|
| IV (5mm$^3$) /cm$^3$ | IV (1mm$^3$) /cm$^3$ | CA /cm$^2$ | SD /cm | IV (5mm$^3$) /cm^3 | IV (1mm^3) /cm^3 | CA /cm$^2$ | SD /cm | |
| GrabNet | 6.88 | 7.43 | 25.5 | 1.02 | 8.30 | 29.17 | 31.4 | 1.61 |
| GraspTTA | - | - | - | - | 3.40 | 4.67 | 16.6 | 4.17 |
| ContactGen | 2.32 | 3.32 | 19.9 | 2.32 | 4.01 | 4.54 | 19.9 | 3.41 |
| FastGrasp | 2.56 | 2.03 | 13.3 | 2.55 | 4.52 | 9.54 | 18.1 | 2.49 |
| FAGrasp | 5.95 | 4.74 | 30.6 | 0.61 | 7.93 | 45.38 | 38.4 | 1.21 |
| Ours | 7.75 | 3.78 | 31.1 | 0.52 | 9.95 | 10.89 | 45.4 | 1.06 |
With the more precise IV criteria, the table shows that our method achieves comparable penetrations to previous state-of-the-art methods, while obviously increases stability. The methods that still show less penetrations in the new criteria (GraspTTA, ContactGe, FastGrasp) are substantially worse in stability (GRAB: ContaqctGen: 2.32, FastGrasp: 2.55 vs. Ours: 0.52; HO3D: GraspTTA:3.41, ContactGen: 2.49 vs. Ours: 1.06) and creates much less contact area (GRAB: ContaqctGen: 19.9, FastGrasp: 13.3 vs. Ours: 31.1; HO3D: GraspTTA:16.6, ContactGen: 19.9 vs. Ours: 45.4) This indicates that these methods are less likely to generate physically functional contact. While FAGrasp achieves the similar stability, there are more penetrations especially in HO3D (45.38 vs. 10.89). This fits the second limitation of legacy IV (5mm$^3$) — FAGrasp tend to generate deep penetrations, while our method does not.
To sum up, the inconsistency comes from both the limitation of legacy IV criteria, and VolCoDiff’s preference for “wide but shallow” grasps. We will make this clear in the updated version.
[1] AffordGrasp: Cross-Modal Diffusion for Affordance-Aware Grasp Synthesis, CVPR 2026
Author Response to the rest concerns
Concern 2: Multiple sample generation per object and uncertainty evaluation.
Question: From the same object, the grasp can be in different hand poses/geometries. How do you evaluate such uncertainty? In your evaluation, only one grasp is produced and evaluated?
We thank the reviewer for this question. In our experiments, we sample 20 grasps for each object and report the average performance across all sampled grasps. We have revised the manuscript to avoid misunderstanding.
Regarding the uncertainty, we use entropy and cluster size to evaluate it in our manuscript. We pool the sampled poses across all objects and apply k-means clustering with k = 20. Entropy is computed over the cluster-assignment distribution, so higher entropy indicates that samples are allocated more uniformly across clusters and hence cover a broader range of distinct grasp modes. The two therefore measure inter-mode and intra-mode diversity respectively.
For ease of reference, we summarize below the results reported in Table 1 of the manuscript. Although our method is not specifically designed to enhance generation diversity, it achieves competitive performance compared with the other methods.
| GRAB | HO3D | |||
|---|---|---|---|---|
| Entropy | Cluster Size | Entropy | Cluster Size | |
| GrabNet | 2.79 | 2.57 | 2.87 | 3.18 |
| GraspTTA | - | - | 2.76 | 0.22 |
| ContactGen | 2.76 | 4.28 | 2.77 | 4.56 |
| FastGrasp | 2.77 | 0.41 | 2.76 | 0.34 |
| FAGrasp | 2.65 | 3.84 | 2.76 | 4.17 |
| Ours | 2.77 | 3.61 | 2.85 | 3.85 |
Concern 3: Why adding prior guidance obviously increases IV?
Question: From Table 4, adding prior guidance significantly increased IV. Why does this happen?
This is due to the limitation of legacy IV we mention in the answer to concern 1 — over-estimating penetrations for hands around the object surface. Table 4 shows the prior guidance obviously increases contact area (2→ 4), indicating the hand is more likely to wrap around the object, so more volumes on object surface now fall into the hand mesh. This validates that prior guidance makes the predicted VolCo combination more valid, and is therefore not a drawback. We have updated our manuscript to avoid confusion.
Concern 4: Generalization to unseen object categories.
Limitation: How does the performance hold up when extending to unseen object categories?
Thanks for the interesting idea. The test set split of GRAB dataset contains 6 objects, where mug and wineglass belong to seen categories of the training set, yet the rest, camera, binoculars, fryingpan, and toothpaste do not fall in a seen category in GRAB. We test the adaptivity from seen to unseen by comparing the performance on the two subsets separately and the delta performance:
| seen | unseen | unseen - seen | |||||||
|---|---|---|---|---|---|---|---|---|---|
| SD↓ | PD↓ | IV↓ | SD↓ | PD↓ | IV↓ | Δ SD (cm)↓ | Δ PD (cm) ↓ | Δ IV (cm$^3$)↓ | |
| GrabNet | 0.15 | 0.10 | 8.24 | 1.45 | 0.55 | 7.03 | 1.30 | 0.45 | -1.21 |
| ContactGen | 1.84 | 0.17 | 2.98 | 2.56 | 0.70 | 3.49 | 0.72 | 0.53 | 0.51 |
| FastGrasp | 0.30 | 0.18 | 1.62 | 3.68 | 0.71 | 2.23 | 3.38 | 0.53 | 0.61 |
| FAGrasp | 0.30 | 0.36 | 3.14 | 0.77 | 0.91 | 5.54 | 0.47 | 0.55 | 2.40 |
| Ours | 0.29 | 0.04 | 5.27 | 0.63 | 0.38 | 3.04 | 0.34 | 0.34 | -2.23 |
Compared to previous methods, our method shows very strong performance on unseen objects. Transferring from seen to unseen, our method presents the smallest increase in simulation displacement (0.34 vs. 0.47 for the strongest baseline) and in penetration depth (0.34 vs. 0.45), indicating that both physical stability and geometric plausibility transfer to unseen categories rather than being fitted to training geometry. Intersection volume decreases on unseen objects (−2.23), which we attribute to the volumetric contact representation being defined on local geometry rather than on category-level object priors. We have added such statement in our manuscript.
Concern 5: Figure label typos
Formatting concern: Figure 2: In the figure, should there be “Volume Decoder” and “Hand Decoder” to produce local hand config and hand mesh?
Yes. The second “Volume Encoder” and “Hand Encoder” are typos, and should be “Volume Decoder” and “Hand Decoder”. We have carried on a thorough proofreading so these typos will be corrected in the final version.
Follow-up on Our Response to Reviewer t8ZY
Dear Reviewer t8ZY
Thank you again for your time and valuable feedback. In our rebuttal we provide detailed clarifications and additional results addressing each of your concerns, including PD-IV analysis, uncertainty evaluation, and generalization to unseen catetories.
As the discussion period draws close to end, we would be grateful for any further questions or remaining concerns, and are happy to provide further clarifications.
Best regards,
Submission18575 Authors
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 4/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper introduces VolCo, a volumetric contact representation constructed from local voxelized cubes sampled around the object surface, as an alternative to conventional surface-based (2D) contact representations. Building on this representation, the authors propose VolCoDiff, a hierarchical latent diffusion framework combining a local VolumeVAE with a global diffusion process, and demonstrate state-of-the-art results on both contact-conditioned hand reconstruction and grasp generation tasks.
Strengths and weaknesses
Main Strength:
- The representational motivation is well-founded and empirically substantiated. Extending contact modeling from surface points to a local volumetric neighborhood is well-motivated. It directly targets a known failure mode of prior optimization-based methods: reliance on non-differentiable nearest-neighbor penetration queries, which cause gradient discontinuities near the medial axis and poor local minima. And some experiments validate this.
- The joint generative formulation is impressive. Rather than adopting the prevailing two-stage paradigm of generating a contact representation followed by post-hoc pose optimization, VolCoDiff jointly models voxel-level contact latents and a global hand pose latent within a unified diffusion process, coupled via a consistency objective (L_cons). Both denoised output can be used as post-optimization tools.
- The proposed representation with voxel. The VolCo formulation is not narrowly tailored to grasp synthesis and could plausibly generalize to other tasks requiring fine-grained contact modeling (e.g., tactile sensing, robotic manipulation planning). Tactile sensing may need more voxels representation than 2D, and could be a general-purpose intermediate representation independent of the specific downstream pipeline.
Main weakness:
- The computational cost analysis is insufficiently comprehensive. Section 4.4 reports cost figures (74.04M vs. 24.41M parameters; 2.01 vs. 13.2 TFLOPs; near-constant inference time as batch size increases) relative only to the point-contact diffusion baseline used in the ablation study. No comparable analysis is provided against the primary baselines evaluated in the main grasp generation experiment (Table 2/3), namely GrabNet, ContactGen, FastGrasp, and FAGrasp. Furthermore, the paper does not report a systematic accuracy, efficiency trade-off. Like, how performance and runtime scale with voxel resolution k or voxel count N — despite this being central to assessing whether the volumetric operator's accuracy gains are achieved at a justifiable computational cost.
- The relationship between the PD and IV metrics is under-analyzed. The observed divergence — a substantial reduction in penetration depth (PD) alongside an increase in intersection volume (IV) — is addressed only briefly and qualitatively (Section 4.2, lines 255–259), attributed to tighter grasps producing a larger, but individually shallower, penetration footprint. This explanation is plausible but not quantitatively substantiated. For example, the relationship between these three, like normalized measure (e.g., IV/CA) or distributional analysis (e.g., a histogram of penetration depths) is provided to directly verify the "broad but shallow" penetration hypothesis. Reporting such a metric would strengthen this claim.
Weak weakness:
- Figure labeling requires correction.In Fig. 2, all decoder modules are erroneously labeled as "encoder." A careful proofreading pass of all figures for labeling and notational consistency is recommended.
- The correspondence between the physical stability model and the simulation-based evaluation exploration.The proposed stability loss explicitly models contact forces via a spring-damper formulation, yet the paper does not discuss whether the PyBullet-based simulation used for evaluation is capable of faithfully capturing this specific physical model, nor whether the two are consistent in their underlying assumptions. Incorporating a simulation-based grasp success rate (e.g., object retention under gravity or applied perturbation) would provide more direct evidence for the paper's implicit assumption that increased contact tightness corresponds to improved functional grasp stability.
Questions
-
Could the authors provide an inference and optimization time cost trade-off comparison against directly diffusion-based grasp generation methods such as FastGrasp? The current computational cost analysis (Sec. 4.4) is only benchmarked against the point-contact diffusion baseline used in the ablation study, not against the primary baselines in the main experiment.
-
The relationship among PD, IV, and CA warrants further discussion. The current experimental results do not clearly disentangle the interplay among these three metrics. I encourage the authors to provide additional clarification along the lines suggested in the Weaknesses section above (e.g., a precise definition of PD, a normalized metric such as IV/CA, or a distributional analysis of penetration depth) to more directly support the "broad but shallow" penetration explanation.
-
Please carefully proofread the manuscript and figures to correct typos and labeling errors (e.g., the decoder modules mislabeled as "encoder" in Fig. 2).
I'd like to re-modify my review if the author consider my suggestions especially the time-cost trade-off on inference.
Limitations
yes. Computational trade-off well discussed during rebuttal.
Final justification
Computational trade-off well discussed during rebuttal. The additional experiments show inference and optimization time clearly. Overall, I think this paper is worth introducing the idea of voxel-grid contact optimization to the community with well-defined task and good evaluation. Additional experiments of inference time shows the trade-off is tolerable. However, whether it's worth setting more hyperparameters and constraints compared to 2D methods, and whether this generalizes well, remains debatable and needs more applications/experiments to justify.
Formatting concerns
I did not identify any major violations of the NeurIPS 2026 formatting or anonymity guidelines (e.g., page limits, template usage, or author-identifying information).
8 comments
Author Response
We would like to thank the reviewer for their positive and constructive feedback. We are encouraged that the reviewer found the method is well-motivated and valuable in downstream tasks. We address the main concerns as below, and have revised the manuscript accordingly.
Concern 1: Computational cost analysis
Weakness: The computational cost analysis is insufficiently comprehensive. Question: could the authors provide an inference and optimization time cost trade-off comparison against directly diffusion-based grasp generation methods such as FastGrasp?
Thank the reviewer for the suggestion. We have performed a detailed comparison of inference time between VolCoDiff and previous methods on GRAB dataset, generating one sample each time. The inference + optimization time breakdown is listed as below. All experiments are run on one single RTX4090 GPU.
| Backbone type | Inference time (s) | Per iteration optimization time (ms) | Optimization time (s) | Total time (s) | GRAB SD (cm) | GRAB PD (cm) | |
|---|---|---|---|---|---|---|---|
| GrabNet | VAE | 0.14 | - | - | 0.14 | 1.02 | 0.40 |
| GraspTTA | VAE | 0.17 | 9.27 | 2.78 | 2.45 | - | - |
| ContactGen | VAE | 0.34 | 36.36 | 43.63 | 43.97 | 2.32 | 0.52 |
| FastGrasp | Diffusion | 8.60 | - | - | 8.60 | 2.55 | 0.53 |
| FAGrasp | VAE | 0.415 | 32.58 | 39.09 | 39.50 | 0.61 | 0.73 |
| PointDiff Baseline (1024) | Diffusion | 2.90 | 4.69 | 4.69 | 7.59 | 1.72 | 0.42 |
| VolCoDiff-S () | Diffusion | 5.48 | 4.89 | 4.89 | 10.37 | 0.67 | 0.32 |
| VolCoDiff () | Diffusion | 5.28 | 5.39 | 5.39 | 10.67 | 0.52 | 0.27 |
Our method shows similar run time as previous diffusion-based baseline (FastGrasp) (~10s & 8.6s), but much better stability (GRAB SD 2.55 → 0.52). The optimization is much faster than SDF-model based optimization methods ContactGen and FAGrasp (10s vs. 40s), and the per-iteration time is the fastest except our point-based baseline. This indicates that our method is simple enough to serve as a diffusion + optimization baseline, with good capacity to extend.
The table also provide a more sparse version with only 64 volumes of resolution (VolCoDiff-S). This version shows similar performance on stability and penetration, yet our full resolution model can perform better, with similar inference time and only ~0.5s more optimization time. This is because the volumes are compressed to 128-dim (64-dim for VolCoDiff-S) latent vectors by VolumeVAE, so the resolution has little impact on the computational complexity during inference. More points make optimization more complicated, but judging from the optimization time, the influence is not obvious due to GPU-parallelism.
Overall, our method achieves a good efficiency-performance trade-off. VolCoDiff-S can be a little faster with some sacrifice in performance, but in most cases the normal sized model VolCoDiff is the first choice.
We will add this analysis to the final version.
Author Response to Concern 2 about IV & PD
Concern 2: Analysis on Interaction Volume (IV) and Penetration Depths (PD).
Weaknesses: The relationship between the PD and IV metrics is under-analyzed. The observed divergence — a substantial reduction in penetration depth (PD) alongside an increase in intersection volume (IV) — is addressed only briefly and qualitatively. Question: The relationship among PD, IV, and CA warrants further discussion. The current experimental results do not clearly disentangle the interplay among these three metrics.
We thank the reviewer for the comment. We would like to first clearly define the 3 metrics, then propose some result to support our “broad but shallow” hypothesis.
Definition of IV, PD and CA: For one grasp sample, penetration depth (PD) is the maximum penetration depth among all hand vertices . We calculate PD using signed distance field, i.e., . Contact area (CA) is the sum of triangle area on object surface with at least one vertex recognized as a contact point (distance to the hand < 5mm). Intersection volume (IV) should ideally be the volume of hand and object mesh intersection, but we follow the convention to calculate it by voxelizing the object and then sum up the voxels whose centers are inside the hand.
Therefore, PD indicates the severity in local penetration, CA reflects the broadness of contact, and IV measures the global intersection. Based on the low PD, large CA, and large IV achieved by our method, we claim that its penetration pattern is “broad but shallow.”.
However, we have discovered that this IV is limited by voxel resolution. So before we analyze the interplay of the 3 metrics, we need to introduce a finer-grained evaluation metric, IV (1 mm$^3$).
A Finer-Grained Metric IV (1 mm$^3$): We introduce a finer-grained evaluation metric, IV (1 mm³), to further substantiate this claim. Following the literature, the IV reported in the paper voxelizes the object with a grid size of 5 mm, and only the voxels crossed by the object surface are retained. While IV (5 mm$^3$) works well for a rough estimation of penetration, it has two limitations at a finer level: thin objects with thickness smaller than 5 mm may be overestimated, and deep penetrations larger than 5 mm may not be fully counted, since only voxels around the object surface are considered.
IV (1 mm$^3$) is computed in a similar way to IV (5 mm$^3$), but with a finer grid size of 1 mm. In addition, the volume inside the object is also considered, which addresses the two limitations mentioned above [1]. We evaluate IV (1 mm$^3$) on the GRAB dataset and summarize the results below.
| Method | SD / cm | IV (1mm$^3$)/cm$^3$ | CA /cm$^2$ | IV / CA /cm | IV (5mm$^3$) /cm$^3$ |
|---|---|---|---|---|---|
| GrabNet | 1.02 | 7.43 | 25.5 | 0.25 | 6.88 |
| ContactGen | 2.32 | 3.32 | 19.9 | 0.17 | 2.32 |
| FastGrasp | 2.55 | 2.03 | 13.3 | 0.13 | 2.56 |
| FAGrasp | 0.61 | 4.74 | 30.6 | 0.21 | 5.95 |
| Ours | 0.52 | 3.78 | 31.1 | 0.10 | 7.75 |
Our method shows a significant decrease in IV (1 mm$^3$) compared with IV (5 mm$^3$) (7.75 → 3.78). This validates our hypothesis that the penetrations produced by our method are relatively broad but shallow. Therefore, when the grid size is reduced, the measured IV is also reduced.
SOTA on Metric IV (1 mm$^3$)/CA: Moreover, we report the metric IV (1 mm$^3$)/CA, where CA denotes the estimated contact area. This metric is not calculated directly from the averaged values in the preceding table. Instead, we compute IV (1 mm$^3$), CA, and their ratio separately for each generated grasp, and then report the average ratio across all generations. Our method achieves state-of-the-art performance among the compared methods, further demonstrating its effectiveness and supporting our “broad but shallow” penetration explanation. We have added the corresponding discussion to the manuscript.
[1] AffordGrasp: Cross-Modal Diffusion for Affordance-Aware Grasp Synthesis, CVPR 2026.
Author Response to Concerns 3 & 4: Typos and Physics model
Concern 3: Figure label typo.
Weakness: Figure labeling requires correction. In Fig. 2, all decoder modules are erroneously labeled as "encoder." A careful proofreading pass of all figures for labeling and notational consistency is recommended. Question: Please carefully proofread the manuscript and figures to correct typos and labeling errors (e.g., the decoder modules mislabeled as "encoder" in Fig. 2).
Thanks for pointing this out. We have carried on a through proofreading and will update all the typos in the final version.
Concern 4: Physics model consistency with PyBullet and simulative success rate metric.
Weakness: The correspondence between the physical stability model and the simulation-based evaluation exploration.
Thanks for the comment. PyBullet uses a complicated constraint/impulse-based force model, different from our spring-damper model. However, two models are consistent in that larger penetrations generally result in larger forces. For training a DNN model, however, PyBullet’s model is too complicated to be formulated as a differentiable loss, so we utilize spring-damper model, which is simple but faithfully approximate the real physics.
For simulation-based measure, we use simulation displacement (SD). It models the displacement of object center of mass after certain steps of simulation. It is the commonly used metric, but we agree that a success-rate measure also helps strengthen the conclusion. The results are reported as below. We report two rates: stable rate based on simulation displacement only and success rate additionally requires the penetration to be less than 5mm.
| GRAB result | Stable rate (SD<2cm) | Success Rate (SD<2cm & PD < 5mm) | HO3D Result | Stable rate (SD<2cm) | Success Rate (SD<2cm & PD < 5mm) |
|---|---|---|---|---|---|
| GrabNet | 0.89 | 0.67 | GrabNet | 0.81 | 0.11 |
| ContactGen | 0.79 | 0.44 | ContactGen | 0.61 | 0.19 |
| FastGrasp | 0.72 | 0.46 | FastGrasp | 0.64 | 0.31 |
| FAGrasp | 0.93 | 0.53 | FAGrasp | 0.88 | 0.13 |
| VolCoDiff | 0.96 | 0.83 | VolCoDiff | 0.88 | 0.42 |
Our method outperforms all previous methods in the two criteria, indicating the strong capability of generating stable and valid grasps. The robotics-style success rate also show the potential to be transferred to robotics.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Author Response to Concern 1: Analysis on IV Metric
We thank the reviewer for the positive feedback and valuable comments. We are encouraged that the reviewer find our method reasonably motivated and strong in performance. We also thank the reviewer for the appreciation of paper presentation and ablation study. For the concerns, we address them one by one as follows:
Concern 1: Analysis on IV metric.
We thank the reviewer for this comment. Our work proposes VolCo, a novel volumetric contact representation for accurate contact modeling and the synthesis of plausible grasps. However, we respectfully note that evaluating grasp plausibility is non-trivial. For example, greater grasp stability often comes at the cost of increased penetration. Conversely, a method can trivially achieve zero penetration by generating grasps that do not reach the object, which would result in a zero grasp success rate. This inherent trade-off makes it difficult for a method to perform well across all evaluation metrics.
Trade-off between IV and PD: We use interaction volume (IV) and penetration depth (PD) to evaluate the generated grasps. Our method achieves a lower PD but a relatively higher IV because it favors stable grasps characterized by broad yet shallow penetration. As shown in the qualitative results in Fig. 5 of the manuscript, our method generates a stable grasp in which the palm wraps around the object, whereas the compared method generates a grasp in which the fingers penetrate the object model. Consequently, our method produces a larger contact area and a higher IV while maintaining a lower PD. In contrast, because the compared method establishes contact primarily through deeply penetrating fingers, it produces a higher PD but a lower IV. The contact area (CA) metric further supports our claim, as our method achieves a larger CA. For ease of reference, we summarize below the CA values of the compared methods reported in our manuscript.
Metric IV (1 mm$^3$): To further validate our claim, we evaluate a new metric IV (1 mm$^3$) in this response. The IV reported in the paper voxelizes the object with a grid size of 5 mm, and only the voxels crossed by the object surface are retained. While IV (5 mm$^3$) works well for a rough estimation of penetration, it has two limitations at a finer level: thin objects with thickness smaller than 5 mm may be overestimated, and deep penetrations larger than 5 mm may not be fully counted, since only voxels around the object surface are considered.
IV (1 mm$^3$) is computed in a similar way to IV (5 mm$^3$), but with a finer grid size of 1 mm. In addition, the volume inside the object is also considered, which addresses the two limitations mentioned above [1]. We evaluate IV (1 mm$^3$) on the GRAB dataset and summarize the results below.
With the more precise IV criteria, the table shows that our method achieves comparable penetrations to previous state-of-the-art methods, while obviously increases stability. The methods that still show less penetrations in the new criteria (GraspTTA, ContactGe, FastGrasp) are substantially worse in stability (GRAB: ContaqctGen: 2.32, FastGrasp: 2.55 vs. Ours: 0.52; HO3D: GraspTTA:3.41, ContactGen: 2.49 vs. Ours: 1.06) and creates much less contact area (GRAB: ContaqctGen: 19.9, FastGrasp: 13.3 vs. Ours: 31.1; HO3D: GraspTTA:16.6, ContactGen: 19.9 vs. Ours: 45.4) This indicates that these methods are less likely to generate physically functional contact. While FAGrasp achieves the similar stability, there are more penetrations especially in HO3D (45.38 vs. 10.89). This fits the second limitation of legacy IV (5mm$^3$) — FAGrasp tend to generate deep penetrations, while our method does not.
To sum up, the inconsistency comes from both the limitation of legacy IV criteria, and VolCoDiff’s preference for “wide but shallow” grasps. We will make this clear in the updated version.
[1] AffordGrasp: Cross-Modal Diffusion for Affordance-Aware Grasp Synthesis, CVPR 2026