REINS: Learning Inertia-Induced Geometry for Physics-Consistent Motion Representation in Clinical Gait Phenotyping
Yiran Ding, Yufei Zhang, Zijun Cui
NeurIPS 2026
TL;DR. REINS compares motion using the body's inertia matrix to reflect mechanical effort. Fine-tuned only on healthy gait, it distinguishes Parkinson's gait from healthy gait, and its scores correlate with clinical severity in unseen cohorts.
Abstract. Parkinson's disease and other gait-related neurological disorders manifest in subtle but biomechanically meaningful changes in how patients move, making computational gait phenotyping a valuable tool for clinical assessment. Yet existing latent representations of motion are typically learned from data alone and miss the biomechanical structure that gives clinical motion its diagnostic meaning, leaving them vulnerable when training cohorts are small or acquisition sites differ. We propose REINS (Riemannian Embedding for INertia-induced Motion Spaces), an Euler-Lagrange informed motion representation that uses the generalized inertia matrix of articulated systems to define a biomechanically grounded geometry on configuration space. Because kinetic energy is itself a quadratic form in velocity weighted by the inertia matrix, this metric is a mechanically determined Riemannian structure, and REINS learns a latent embedding of the resulting structured space. By defining the representation space itself through rigid-body dynamics rather than enforcing physics as a post-hoc penalty, REINS aligns the geometry of motion representation with the same physical laws clinicians rely on to interpret gait. On Parkinson's disease (PD) gait analysis, REINS measures deviation from healthy motion as a Riemannian distance under the inertia-induced metric, and improves healthy-control (HC) vs. PD discrimination and Unified Parkinson's Disease Rating Scale (UPDRS) gait severity correlation. Code is available at https://github.com/DominoAI-Lab/REINS-NeurIPS-2026.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:42 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
In this paper, the authors propose REINS, a physics-consistent motion representation framework for clinical gait phenotyping. Rather than learning the geometry of the latent space purely from data, the method derives a Riemannian metric from the generalized inertia matrix of an articulated human body and uses this geometry to construct motion representations for Parkinson's disease gait analysis. I find the central idea technically interesting and well motivated, particularly the decision to incorporate biomechanics directly into the representation space instead of treating physics as a post-hoc regularization.
The reviews are mixed, but there is broad agreement that the paper presents an interesting and well-motivated idea. Reviewer 2Efi describes the formulation as principled and elegant, particularly the use of the inertia matrix to define a physics-consistent geometry for motion representation learning. Reviewer 6qUG similarly finds the motivation clear and appreciates the connection between inertia-induced Riemannian geometry and motion representation learning. In general, the empirical results receive positive assessments from the reviewers, especially in the low-data and cross-cohort settings, where the proposed inductive bias is well aligned with the intended clinical application.
Nevertheless, my main concerns lie in the evaluation protocol. Both Reviewers NdY6 and 2Efi question whether the current experiments adequately isolate the source of the reported improvements. Reviewer 2Efi specifically recommends a 3×2 ablation that separates the effects of the learned representation, the pullback metric, and the inertia-induced geodesic. Reviewer NdY6 raises the closely related concern that the current experiments do not isolate the contribution of the proposed loss from that of the scoring distance. I agree that this is the key issue for the rebuttal because it is currently unclear which component accounts for the reported improvements. Beyond this, the remaining concerns are relatively minor and mostly relate to presentation and completeness, including the unresolved "Section ??" cross-reference noted by both Reviewers 6qUG and 2Efi and insufficient detail on the geodesic scoring procedure.
The main priority for the rebuttal is to provide stronger empirical evidence that isolates the source of the reported performance gains. In particular, the authors should clarify the respective contributions of the learned representation, the pullback metric, and the inertia-induced geodesic scoring procedure. If the authors can address this point and the remaining clarification issues, I believe many of the current concerns would be resolved.
Final justification
During rebuttal, the authors addressed the central concern raised in my initial meta-review about the source of the reported gains. In particular, they provided the requested ablation separating the effects of the fine-tuning objective, the decoder pullback, and the inertia-induced metric. They also added subject-level confidence intervals, repeated-subject-split results, and comparisons with published motion priors. These additions make the empirical contribution considerably clearer and, in my view, resolve the main attribution issue. Accordingly, Reviewer 2Efi increased the score, and Reviewer NdY6 agreed that most of the original concerns had been addressed.
(1) Methodological Contribution and Technical Soundness: I view this as a meaningful formulation-level contribution. Rather than serving only as a post-hoc regularizer, the mechanically determined inertia geometry shapes both the learned representation and its geodesic readout for clinical gait phenotyping. This gives the representation a clear biomechanical interpretation and is particularly relevant in the limited-data setting, since the inertia matrix is obtained from the body model and pose rather than estimated from the clinical cohort. More importantly, the new ablation shows that both the fine-tuning objective and the scoring geometry contribute to the final performance, with their combination giving the strongest results. Reviewer 6qUG also finds the method technically sound and considers the authors' explanations of the inertia matrix and geodesic computation satisfactory.
(2) Empirical Evaluation and Robustness: The evaluation covers disease discrimination, data-scarcity settings, and severity analysis across external cohorts. In response to the reviews, the authors strengthened this evaluation with comparisons to VPoser and GaitForeMer, repeated splits, and confidence intervals. During the subsequent discussion, Reviewer NdY6 identified two discrepancies: the original nearest-neighbor graph made the evaluation transductive, and the reported results used a constant approximation rather than the pointwise pullback metric described in the paper. The authors acknowledged both issues and repeated the evaluation using an inductive graph and the pointwise metric. The main results remained essentially unchanged. I therefore view these discrepancies as correctable protocol issues rather than problems that alter the main empirical conclusion. The corrected protocol and results should be documented clearly in the final revision.
The main remaining concern is the scope of the contribution. At present, the evaluation covers only a limited number of motion priors and datasets, and broader validation would strengthen the paper. Even so, I consider the contribution within the current scope non-trivial. In particular, defining both the representation and its readout through inertia-induced geometry is novel and technically meaningful. The new ablations further show that both parts of the design contribute to performance. Moreover, the main results remain essentially unchanged after correcting the evaluation protocol. In my assessment, the paper's conceptual and empirical strengths therefore outweigh this limitation.
In summary, the rebuttal has addressed the central concern in my initial meta-review and strengthened the evidence for the proposed method. For this reason, I consider this paper a good candidate for acceptance and encourage the authors to report the corrected inductive evaluation, distinguish the pointwise metric from its constant approximation as well as clarify the scope of the contribution in the final version.
Read meta-review
Meta-review
In this paper, the authors propose REINS, a physics-consistent motion representation framework for clinical gait phenotyping. Rather than learning the geometry of the latent space purely from data, the method derives a Riemannian metric from the generalized inertia matrix of an articulated human body and uses this geometry to construct motion representations for Parkinson's disease gait analysis. I find the central idea technically interesting and well motivated, particularly the decision to incorporate biomechanics directly into the representation space instead of treating physics as a post-hoc regularization.
The reviews are mixed, but there is broad agreement that the paper presents an interesting and well-motivated idea. Reviewer 2Efi describes the formulation as principled and elegant, particularly the use of the inertia matrix to define a physics-consistent geometry for motion representation learning. Reviewer 6qUG similarly finds the motivation clear and appreciates the connection between inertia-induced Riemannian geometry and motion representation learning. In general, the empirical results receive positive assessments from the reviewers, especially in the low-data and cross-cohort settings, where the proposed inductive bias is well aligned with the intended clinical application.
Nevertheless, my main concerns lie in the evaluation protocol. Both Reviewers NdY6 and 2Efi question whether the current experiments adequately isolate the source of the reported improvements. Reviewer 2Efi specifically recommends a 3×2 ablation that separates the effects of the learned representation, the pullback metric, and the inertia-induced geodesic. Reviewer NdY6 raises the closely related concern that the current experiments do not isolate the contribution of the proposed loss from that of the scoring distance. I agree that this is the key issue for the rebuttal because it is currently unclear which component accounts for the reported improvements. Beyond this, the remaining concerns are relatively minor and mostly relate to presentation and completeness, including the unresolved "Section ??" cross-reference noted by both Reviewers 6qUG and 2Efi and insufficient detail on the geodesic scoring procedure.
The main priority for the rebuttal is to provide stronger empirical evidence that isolates the source of the reported performance gains. In particular, the authors should clarify the respective contributions of the learned representation, the pullback metric, and the inertia-induced geodesic scoring procedure. If the authors can address this point and the remaining clarification issues, I believe many of the current concerns would be resolved.
Final justification
During rebuttal, the authors addressed the central concern raised in my initial meta-review about the source of the reported gains. In particular, they provided the requested ablation separating the effects of the fine-tuning objective, the decoder pullback, and the inertia-induced metric. They also added subject-level confidence intervals, repeated-subject-split results, and comparisons with published motion priors. These additions make the empirical contribution considerably clearer and, in my view, resolve the main attribution issue. Accordingly, Reviewer 2Efi increased the score, and Reviewer NdY6 agreed that most of the original concerns had been addressed.
(1) Methodological Contribution and Technical Soundness: I view this as a meaningful formulation-level contribution. Rather than serving only as a post-hoc regularizer, the mechanically determined inertia geometry shapes both the learned representation and its geodesic readout for clinical gait phenotyping. This gives the representation a clear biomechanical interpretation and is particularly relevant in the limited-data setting, since the inertia matrix is obtained from the body model and pose rather than estimated from the clinical cohort. More importantly, the new ablation shows that both the fine-tuning objective and the scoring geometry contribute to the final performance, with their combination giving the strongest results. Reviewer 6qUG also finds the method technically sound and considers the authors' explanations of the inertia matrix and geodesic computation satisfactory.
(2) Empirical Evaluation and Robustness: The evaluation covers disease discrimination, data-scarcity settings, and severity analysis across external cohorts. In response to the reviews, the authors strengthened this evaluation with comparisons to VPoser and GaitForeMer, repeated splits, and confidence intervals. During the subsequent discussion, Reviewer NdY6 identified two discrepancies: the original nearest-neighbor graph made the evaluation transductive, and the reported results used a constant approximation rather than the pointwise pullback metric described in the paper. The authors acknowledged both issues and repeated the evaluation using an inductive graph and the pointwise metric. The main results remained essentially unchanged. I therefore view these discrepancies as correctable protocol issues rather than problems that alter the main empirical conclusion. The corrected protocol and results should be documented clearly in the final revision.
The main remaining concern is the scope of the contribution. At present, the evaluation covers only a limited number of motion priors and datasets, and broader validation would strengthen the paper. Even so, I consider the contribution within the current scope non-trivial. In particular, defining both the representation and its readout through inertia-induced geometry is novel and technically meaningful. The new ablations further show that both parts of the design contribute to performance. Moreover, the main results remain essentially unchanged after correcting the evaluation protocol. In my assessment, the paper's conceptual and empirical strengths therefore outweigh this limitation.
In summary, the rebuttal has addressed the central concern in my initial meta-review and strengthened the evidence for the proposed method. For this reason, I consider this paper a good candidate for acceptance and encourage the authors to report the corrected inductive evaluation, distinguish the pointwise metric from its constant approximation as well as clarify the scope of the contribution in the final version.
1 comment
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 2/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This work argues that the inertia matrix can provide a useful representation for analyzing the gait kinematics of Parkinson's disease (PD) patients. Concretely, it
- claims that gait phenotyping is a more useful objective than reconstruction quality, and proposes REINS, a model fine-tuned from PhysPT
- demonstrates that REINS enables more meaningful analysis on a PD gait benchmark.
Strengths and weaknesses
Strengths
- The core idea is principled and elegant. Using the inertia matrix as the geometry of the representation itself, rather than as a post-hoc penalty on reconstruction, is a fresh framing. The derivation of a Riemannian metric from the fact that kinetic energy is a quadratic form in velocity, , is mechanically grounded and convincing.
- The empirical gap is large and consistent. In Table 1, the jump from the Euclidean baselines (0.52–0.61) to the geodesic distance (0.87–0.90) is effectively a leap from near-chance to strong discrimination, and the data efficiency in Table 2 (retaining 0.76 AUROC down to K=1) has real value in the clinical data-scarcity regime.
- The zero-shot transfer results support the central claim. Without per-cohort calibration, the UPDRS correlations are positive across all four heterogeneous cohorts (PD-GaM, BMCLab, T-SDU-PD, 3DGait) and substantially exceed the Euclidean baselines (Table 3), which is consistent with the hypothesis that a mechanical prior is invariant to site/protocol.
Weaknesses
Major
- The central claim (reorganization of the latent space) is supported only by indirect evidence. The narrative centers on the structure of the latent space, but the experimental results (improved AUROC) do not separate whether the gain comes from (i) a structural reorganization of the latent space, (ii) changing the distance from a raw Euclidean distance in the latent to an inertia-induced geodesic, or (iii) simply the pullback through the decoder Jacobian . Supporting the claim requires direct evidence that disentangles these factors (see the 3×2 ablation in Question 3). This is the decisive reason the review leans toward rejection.
- Statistical rigor is lacking for a clinical paper. No confidence intervals are provided for key metrics such as AUROC (Tables 1, 2). It is not stated which test the significance in Table 3 refers to. Moreover, four entries in Table 2 (data-driven K=1; physics-supervised K=5/K=3/K=1) have AUROC below chance (0.5), and this is not adequately explained. For the credibility of a clinical claim, variance estimates (e.g., k-fold) and confidence intervals are needed.
Moderate
- Engagement with the motion-prior representation literature is thin. Since this work proposes a motion representation, it should be deeply grounded in the motion-prior literature. However, it relies on a single backbone (PhysPT), and comparison with / discussion of the broad body of prior work on human motion prior representations themselves (e.g., latent motion models such as VPoser, HuMoR, and motion-VAE-style methods) is missing. The bibliography is also sparse overall (17 references in total). (WHAM [13] and SimPoE [15] use priors to solve downstream tasks rather than studying the structure of the representation itself, so they do not substitute for this grounding.)
Minor
- For readability, abbreviations should be spelled out before use. Terms like PD and HC are not commonly used at venues like NeurIPS and should be defined in advance. The same applies to manual abbreviations such as EL.
- LaTeX references are broken at lines 150 and 174 ("Section ??").
- Line 38–39, "unexplored.Such" a space is missing between the sentences.
Questions
- If there is a reason for choosing PhysPT among the many motion priors, please explain. In Tables 1 and 2, physics-supervised performs worse than data-driven in most settings. if so, I am curious why the pretrained model was not chosen to be purely data-driven.
- Please explain how the normal reference distribution at line 173 is computed. I could not find the relevant details in the text. My guess is that at K=1 in Table 2, only the z-values of the training subject(s) are used... is my understanding correct? If so, at K=1 the AUROC would seem to swing greatly depending on which subject is selected.
- To fairly isolate the role of the mass matrix , a 3×2 comparison of (3 distances) × (2 fine-tuning conditions) is needed. Currently in Table 1 the Euclidean baseline is measured as a raw Euclidean distance in the latent , while ours is measured as a geodesic distance under the pullback metric , so it is not separated whether the improvement is due to (i) or (ii) simply the pullback through the decoder Jacobian .
- Distance (3): (a) Euclidean: raw Euclidean distance in the latent (b) geodesic: pullback distance with (reflecting only the decoder Jacobian) (c) geodesic: full inertia metric (ours).
- Fine-tuning (2): (1) without , and (2) with (REINS).
- This isolates each factor: (a)/(b) is the net effect of the pullback through (b)/(c) is the net contribution of the mass matrix (on the same pullback footing, vs. ) and (1)/(2) is the latent restructuring effect from . As reported, only some of these cells are shown, so the effect of , the effect of , and the change in latent structure are confounded.
- I do not understand why four entries in Table 2 have AUROC below the random-label value of 0.5. Please perform k-fold validation on Tables 1 and 2 and provide confidence intervals. With confidence intervals, there may be room to make sense of this.
Limitations
It would be very meaningful to verify whether the proposed logic applies across a variety of motion priors. Also, from a dynamics standpoint only the mass matrix is analyzed. From a biomechanics standpoint, it would be worth analyzing the muscle Jacobian as well. That is, analyzing the operating range of the muscles.
Final justification
I update my score to 4: Borderline Accept.
The rebuttal resolved my main concerns. The new 3×2 ablation separates the effects of the representation, decoder pullback, and inertia matrix. The added confidence intervals and split results also address the statistical concerns.
The authors clarified the reference construction, the (K=1) setting, the choice of PhysPT, and the external baseline protocol.
Some limitations remain. The evaluation is still based on a limited number of motion priors and datasets, so the generality of the method is not fully established. However, I do not consider these issues strong enough to reject the paper.
Overall, the main technical concerns were addressed, while the remaining issues mainly affect the strength of the acceptance rather than the validity of the contribution.
Formatting concerns
None
3 comments
Rebuttal
We thank Reviewer 2Efi for the careful reading and for the specific, actionable suggestions. We respond to each point below.
- Isolate the source of the reported improvements (Responding to Major Weakness 1 and Question 3) We ran the 3*2 ablation. We factor the scorer into distance * representation and vary each independently: Distance: Euclidean, J^TJ geodesic (pullback distance under M=I), J^TMJ geodesic (full inertia matrix) Representation: without L_rec, with L_rec All six values of K, subject-level, with the confidence intervals described in A4.
Subject-level HC vs PD AUROC at K=20 (95% CI).
| Fine-tuning | Euclidean | J^T J geodesic | J^T M J geodesic |
|---|---|---|---|
| Without L_rec (D) | 0.5167 [0.3167, 0.7125] | 0.5500 [0.3542, 0.7417] | 0.5833 [0.3875, 0.7667] |
| With L_rec (F) | 0.6208 [0.4250, 0.8000] | 0.7292 [0.5500, 0.8792] | 0.8958 [0.7833, 0.9792] |
- Confidence intervals, significance test, and below-chance entries (Responding to Major Weakness 2 and Question 4) About confidence intervals (Tables 1, 2): We add 95% intervals to every entry, for both the HC vs PD and the HC vs PD+other columns. Evaluation subjects are resampled with replacement 2000 times, with HC and the positive class drawn separately so both are always present, and AUROC is recomputed on each draw. Where two methods are compared, the same resampled subjects are used for both and the interval is formed on their difference. We also rerun the main setting over several random subject splits and report mean ± sd.
Table 1*: main setting over several random subject splits and report mean ± sd
| Method | HC/PD, seed-0 [95% CI] | HC/PD, mean ± sd | HC/all, seed-0 [95% CI] | HC/all, mean ± sd |
|---|---|---|---|---|
| Data-driven | 0.5750 [0.3792, 0.7625] | 0.5633 ± 0.050 | 0.6087 [0.4312, 0.7736] | 0.5988 ± 0.034 |
| Physics-supervised | 0.5167 [0.3167, 0.7125] | 0.5242 ± 0.049 | 0.5380 [0.3587, 0.7156] | 0.5442 ± 0.033 |
| EL-Riemannian | 0.8958 [0.7833, 0.9792] | 0.8783 ± 0.036 | 0.8678 [0.7609, 0.9475] | 0.8551 ± 0.026 |
About Table 3: the asterisks mark p < 0.05 against the null of zero rank correlation. The p-values are those returned by scipy’s spearmanr and kendalltau (τ-b). The unit is the subject, so n is the number of subjects in each cohort, as given in the table header. We add this to the caption.
About the four below-chance entries: With 8 HC and 30 PD subjects, an uninformative score has a 95% range of roughly [0.28, 0.72], so values in the 0.43-0.48 range are not separable from chance. Their bootstrap intervals include 0.5. We report these intervals in the revised Tables 1 and 2.
- Engagement with the motion-prior representation literature (Responding to Moderate Weakness) About comparison/discussion of prior work: We expand the related work with the latent motion-prior line, including VPoser, GaitForeMer
External baselines for Anomaly detection AUROC at K=20 HC training subjects
| Method | HC/PD | HC/all |
|---|---|---|
| VPoser | 0.5743 | 0.6224 |
| GaitForeMer | 0.7135 | 0.7577 |
| Ours | 0.8958 | 0.8678 |
-
Abbreviations (Responding to Minor Weakness 1) We will spell out Parkinson’s Disease, Health Control, Euler-Lagrange and any abbreviations that may have caused confusion and ambiguouty
-
Broken Cross-reference (Responding to Minor Weakness 2) The two broken references at lines 150 and 174 should have pointed to Sec 3.4 (Learning a Latent Embedding). We will fix them
-
Missing Space (Responding to Minor Weakness 3) We will add the missing space at line 38
-
Choice of PhysPT as a backbone (Responding to Question 1) About the choice of backbone: Our starting point is that the representation should carry physical structure, and PhysPT is the pretrained monocular model whose objective already contains force, contact and Euler-Lagrange terms. The motion priors in the literature we are aware of, including VPoser and HuMoR, are kinematic. Starting from PhysPT is what makes the comparison in this paper possible, which moves physics from a trajectory-level penalty into the geometry of the representation, and conditions D and F differ exactly by that substitution.
About physics-supervised performing worse and the choice of pretrained model: All conditions start from the same AMASS-pretrained PhysPT checkpoint and differ only in the fine-tuning objective. Condition C is the purely data-driven fine-tuning, and it is reported. So Condition C > Condition D is because of the fine-tuning loss instead of the pretraining. We have not tested a purely data-driven pretrained backbone.
- How the normal reference is computed (Responding to Question 2) The reference is built only from the windows of the K training-HC subjects, which at K = 1 is the 97 windows of a single subject.
The two readouts use those windows differently. For the Euclidean readout, μ_N is their sample mean, with covariance estimated by Ledoit-Wolf shrinkage. For the geodesic readout there is no single reference point: every training-HC window is a source in the k-NN graph, and a window's score is the shortest-path length to the nearest of them. The notation at line 173 describes the Euclidean case, and we will make the geodesic case explicit in Sec 3.5.
When K = 1 the single training subject is fixed by the split seed, so the result does depend on which subject is drawn. The multiple-split runs reported in A4 quantify how much it varies.
-
Generality across motion priors (Responding to Limitations) We agree on both and add them to the Limitations. About motion priors, we are adding one external backbone under our protocol (see R3) and note that a systematic check across priors remains open.
-
The muscle Jacobian (Responding to Limitations) About the muscle Jacobian: a musculoskeletal model with muscle paths and activation estimates is needed, which in practice requires EMG, while CARE-PD provides pose only, so we cannot evaluate it on this benchmark.
We thank the authors for the rebuttal; we have checked each component.
(1), (2) We appreciate the authors running the requested 3x2 ablation and adding the confidence intervals, split variability, which together address Major Weaknesses 1 and 2.
(3) No protocol is given for how the VPoser and GaitForeMer numbers were produced, so we have not taken this table into account.
(4) The expansion is "Healthy Control", not "Health Control".
(10) We did not mean EMG. Given a scaled musculoskeletal model, muscle-tendon lengths and hence moment arms R(q) = ∂l_MT/∂q are functions of pose alone, so this analysis is accessible from CARE-PD and would supply a second mechanically meaningful quadratic form alongside M(q). Worth noting in the Limitations, though not required for acceptance.
We update our rating to 4: Borderline accept.
We thank Reviewer 2Efi for the follow up and for reconsidering our submission.
(3) Protocol for external baselines. We apologize for omitting the protocol. And we provide the details below.
Setup: Both baselines are evaluated with frozen backbones, following CARE-PD’s convention for pretrained encoders (its classifier_only mode freezes the backbone). The 20 HC subjects define the reference set and are not used to adapt either model.
Shared protocol: Each recording is divided into 16-frame windows sampled at 30 fps. For each window, we extract a latent representation using the corresponding frozen encoder and compute its anomaly score using the geodesic procedure described in Sec 3.5. A subject-level score is obtained by taking the median across all windows from that subject. AUROC is computed on the 8 held-out HC against the 30 PD subjects (HC/PD) and against the 30 PD plus 39 other-disease subjects (HC/all).
VPoser: We use the V02_05 checkpoint pretrained on AMASS. Because it is a per-frame pose with no temporal axis, each frame is encoded independently, and the window defines only the interval over which we average. For each frame we encode the 21 SMPL body-pose joints and take the 32-dimensional posterior mean. The window latent representation is the average over the 16 frames.
GaitForeMer: We use the released checkpoint pre-trained on NTU RGB+D. We feed CARE-PD’s 3D Human3.6M joints, reindexed to the checkpoint’s joint ordering. The window latent representation is the temporally pooled encoder output.
(4) Healthy Control. Sorry for the typo and thank you for pointing it out. It should be “Healthy Control”
(10) Moment Arms. Thank you for the correction. Our previous response conflated pose-derived muscle geometry with the estimation of muscle activations. Given a scaled musculoskeletal model, moment arms can be computed from pose without EMG and can define a complementary muscle-induced geometry. This is a very interesting point. We will note the absence of this analysis as a limitation in the manuscript and would like to explore this direction further in future work.
- Rating
- 3/6
- Confidence
- 5/5
- Quality
- 2/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
REINS learns a low-dimensional, physics-informed motion representation for Parkinson's Disease (PD) gait phenotyping where geometry is fixed by rigid-body mechanics instead of learned from data. Modeling the body as an articulated rigid-body system, the authors use its generalized inertia matrix to define a Riemannian metric on configuration space, replace PhysPT's Euler-Lagrange residual with an inertia-weighted reconstruction loss, and score each subject by the geodesic distance from their embedding to a healthy-control reference. They evaluate on the CARE-PD dataset for HC-vs-PD discrimination, repeat the evaluation as the number of HC training subjects shrinks, and test zero-shot correlation with UPDRS-gait severity on four external cohorts. The central claim is that a biomechanically grounded representation of motion transfers across cohorts and has low performance degradation even with fewer samples.
Strengths and weaknesses
The core idea is sound, and the standout is the low-data result, where the geodesic readout still separates HC from PD with a single HC subject for fine-tuning while both Euclidean baselines fall below chance. My main reservation is that the central HC-vs-PD comparison changes the loss and the scoring distance together, so the reported gain can't yet be pinned on the proposed loss, and there are no external baselines and no measure of variance. More details below:
Strengths:
- The generalized inertia matrix is a function of segment mass and geometry, so it's available as an inductive bias regardless of cohort size. This is what underwrites the method's behavior in the data-scarce regime.
- With only a single HC subject used for fine-tuning (=1), the geodesic readout retains 0.76 AUROC while both Euclidean baselines collapse below chance to 0.43 and 0.44 (Table 2).
- Section 4.1 specifies the optimizer, learning rate, batch size, schedule, window length, and early-stopping criterion, so the training is reproducible at the configuration level. The authors are also transparent about limitations, such as: subject mass is taken from a generic SMPL model rather than measured per patient, the HC reference is drawn from a single dataset, and each subject is reduced to a median window-level score.
Weaknesses
- The paper's main result is the HC-vs-PD comparison in Table 1, where the geodesic method (condition F) reaches 0.90 AUROC against 0.52 to 0.58 for the two Euclidean baselines. That comparison confounds the training loss with the scoring distance, since condition F changes both relative to the baselines. The authors even note that re-equipping the same encoder with the geodesic distance recovers most of the separability gap (lines 234-236), which points to the distance rather than as the driver. No condition isolates the two, so the gain can't be attributed to the proposed loss.
- Every method in Table 1 is essentially a variant of the same model. GaitForemer [3] and the diffusion-based scorer [5] are cited but not actually run as baselines.
- The results don't report any uncertainty, e.g., standard deviations, which the authors confirm in checklist Q7.
- The cohorts are small, the PD subject count in the DNE subset isn't mentioned, and the claimed widening of the gap as shrinks rests on a change from 0.32 AUROC at =20 to 0.33 at =1, which is minimal and doesn't seem significant. It also contradicts the Table 2 caption, which mentions that the gap widens as grows.
- The scoring procedure is confusing/incomplete. The pullback metric scording depends on is referenced in a missing section, "Section ??" (line 174), and the neighbor count and the support over which the NN graph is built are unspecified (Sec. 3.5).
Questions
- If you score the PhysPT-trained encoder (condition D) with the geodesic distance, and the REINS-trained encoder (condition F) with the Euclidean readout, what AUROC do you get? If geodesic-scored D matches F, the gain is the distance and not the loss, and I'd want the paper reframed. If F stays high with the Euclidean readout, that's strong support for the loss and would raise my assessment on Quality.
- Can you run at least one published method, GaitForemer [3] or the diffusion scorer [5], on the same DNE split? A clear margin over a published method would strengthen the generalization of your methods.
- Can you repeat the main runs over several random splits and report each number as a mean with spread, plus a test on the main PD vs. HC comparison?
- How many PD and other-disease subjects are in DNE, and what's the HC-to-PD ratio behind Table 1?
Limitations
The authors did so partly with calling out the main ones. I'd add how sensitive the scores are to errors in the monocular pose estimates that feed the inertia matrix, and I'd replace "this work doesn't have negative impacts" (line 651) with acknowledging the real risks of a clinical screening score, such as bias across body types and demographics.
Final justification
N/A
Formatting concerns
N/A
5 comments
Rebuttal
We thank Reviewer NdY6 for the careful reading and for the specific, actionable suggestions. We respond to each point below.
- Isolate the source of the reported improvements (Responding to Weakness 1 and Question 1)
We ran the ablation that separates the two. The encoder and the scoring distance are varied independently: Encoder: without L_rec (condition D), with L_rec (condition F) Scoring distance: Euclidean, geodesic
Subject-level HC vs PD AUROC at K=20 (95% CI).
| Encoder | Euclidean | Geodesic |
|---|---|---|
| Physics-supervised (without L_rec) | 0.5167 [0.3167, 0.7125] | 0.5833 [0.3875, 0.7667] |
| REINS (with L_rec) | 0.6208 [0.4250, 0.8000] | 0.8958 [0.7833, 0.9792] |
- Comparison to External Baselines (Responding to Weakness 2 and Question 2)
External baselines for Anomaly detection AUROC at K=20 HC training subjects | Method | HC/PD | HC/all | |---|---|---|---| | VPoser | 0.5743 | 0.6224 | | GaitForeMer | 0.7135 | 0.7577 | | Ours | 0.8958 | 0.8678 |
- Uncertainty estimates: random splits and a test on the main PD vs. HC comparison (Responding to Weakness 3 and Question 1)
We repeat the main setting over multiple random splits and report mean ± sd.
(1) Multiple splits: We rerun the main setting with several random train/eval splits and report mean ± sd across them.
Uncertainty estimates
| Method | HC/PD, seed-0 [95% CI] | HC/PD, mean ± sd | HC/all, seed-0 [95% CI] | HC/all, mean ± sd |
|---|---|---|---|---|
| Data-driven | 0.5750 [0.3792, 0.7625] | 0.5633 ± 0.050 | 0.6087 [0.4312, 0.7736] | 0.5988 ± 0.034 |
| Physics-supervised | 0.5167 [0.3167, 0.7125] | 0.5242 ± 0.049 | 0.5380 [0.3587, 0.7156] | 0.5442 ± 0.033 |
| EL-Riemannian | 0.8958 [0.7833, 0.9792] | 0.8783 ± 0.036 | 0.8678 [0.7609, 0.9475] | 0.8551 ± 0.026 |
(2) A test on the main HC-vs-PD comparison: We resample the evaluation subjects with replacement 2000 times, drawing HC and PD separately so both groups are always present, and recompute AUROC each time to obtain a 95% interval. When comparing two methods we use the same resampled subjects for both and form the interval on their difference, so an interval that excludes zero means the difference is larger than subject-sampling noise.
Panel A: Primary comparisons at K = 20. Paired differences in subject-level AUROC (95% CI)
| Comparison | HC/PD | HC/all |
|---|---|---|
| EL-Riemannian − Data-driven | +0.3208 [+0.1083, +0.5333] | +0.2591 [+0.0688, +0.4493] |
| EL-Riemannian − Physics-supervised | +0.3791 [+0.1583, +0.6000] | +0.3298 [+0.1286, +0.5308] |
Panel B: Sensitivity to the neighbourhood size K (HC/PD). Paired differences in subject-level AUROC (95% CI) across K.
| K | EL-Riemannian − Data-driven | EL-Riemannian − Physics-supervised |
|---|---|---|
| 20 | +0.3208 [+0.1083, +0.5333] | +0.3791 [+0.1583, +0.6000] |
| 15 | +0.2792 [+0.0625, +0.4958] | +0.3250 [+0.1000, +0.5500] |
| 10 | +0.2750 [+0.0458, +0.5042] | +0.2958 [+0.0667, +0.5250] |
| 5 | +0.2583 [+0.0250, +0.4917] | +0.3250 [+0.0875, +0.5625] |
| 3 | +0.2500 [+0.0167, +0.4833] | +0.3083 [+0.0708, +0.5458] |
| 1 | +0.3333 [+0.0917, +0.5750] | +0.3208 [+0.0792, +0.5625] |
- Cohort composition of DNE (Responding to Weakness 1 and Question 4)
DNE has 28 HC, 30 PD, and 39 other-disease subjects. In Table 1 (K = 20), 20 HC subjects are used for fine-tuning and as the reference; the AUROC is computed on the 8 held-out HC against the 30 PD subjects, so the HC:PD ratio is 8:30. PD and other-disease subjects are never used during fine-tuning. We will add these counts to Sec 4.1 (Experimental Setup).
- About the claimed widening of the gap (Responding to Weakness 1)
we drop the claim and fix the caption.
- Broken Cross-reference
About Section ??: The two "Section ??" references should have pointed to Sec 3.4 (Learning a Latent Embedding)
- Clarifications on geodesic computation details
About the pullback metric and the kNN graph: We will expand Sec 3.5 (Anomaly Detection via Inertia-Induced Distance) with the full scoring procedure as follows: Latents are reduced by PCA (0.95 variance) and the leading component, which corresponds to global translation along the walking direction, is removed. The pullback map J from latent to pose space is fitted by ridge regression on the training-HC windows, giving the metric G = J^T M J with M the training-HC mean inertia matrix. We build a k-NN graph with k=20 over all windows, weight each edge by its length under G, and run multi-source Dijkstra with sources restricted to training-HC windows. A window's score is the shortest-path length to the nearest source, and a subject’s score is the median over their windows.
- Sensitivity to monocular pose estimates (Responding to Limitations)
We will add both limitations. The inertia matrix is computed from SMPL parameters recovered from monocular video, so pose estimation error propagates into M(q) and into the resulting distances. We have not measured how large that effect is.
- Risks of a clinical screening score (Responding to Limitations)
We remove the claim of no negative impacts and replace it with the risks of a clinical screening score, including that our inertia matrix is built on a generic SMPL body rather than per-subject anthropometry.
We thank the reviewer for the detailed review, and wanted to follow up in case anything in our response is still open.
Isolate the source of the reported improvements (follow-up) As the ablation table shows, both L_rec, which is what changes the encoder, and the geodesic contribute to the improvement, with L_rec the larger of the two
Comparison to external baselines (follow-up) The table in our previous message did not render, so we repost it here.
| Method | HC/PD | HC/all |
|---|---|---|
| VPoser | 0.5743 | 0.6224 |
| GaitForeMer | 0.7135 | 0.7577 |
| Ours | 0.8958 | 0.8678 |
Below is the protocol of external baselines
Setup: Both baselines are evaluated with frozen backbones, following CARE-PD’s convention for pretrained encoders (its classifier_only mode freezes the backbone). The 20 HC subjects define the reference set and are not used to adapt either model.
Shared protocol: Each recording is divided into 16-frame windows sampled at 30 fps. For each window, we extract a latent representation using the corresponding frozen encoder and compute its anomaly score using the geodesic procedure described in Sec 3.5. A subject-level score is obtained by taking the median across all windows from that subject. AUROC is computed on the 8 held-out HC against the 30 PD subjects (HC/PD) and against the 30 PD plus 39 other-disease subjects (HC/all).
VPoser: We use the V02_05 checkpoint pretrained on AMASS. Because it is a per-frame pose with no temporal axis, each frame is encoded independently, and the window defines only the interval over which we average. For each frame we encode the 21 SMPL body-pose joints and take the 32-dimensional posterior mean. The window latent representation is the average over the 16 frames.
GaitForeMer: We use the released checkpoint pre-trained on NTU RGB+D. We feed CARE-PD’s 3D Human3.6M joints, reindexed to the checkpoint’s joint ordering. The window latent representation is the temporally pooled encoder output.
Please let us know if anything is still unclear.
Thank you for the detailed rebuttal and the added experiments. The response addresses most of my concerns.
-
The ablation addressing W1 and Q1 does separate the training objective from the scoring distance, which was the main missing comparison. Adding improves the Euclidean AUROC significantly, and using the geodesic score with the PhysPT encoder improves it as well. The full method's results being at 0.8958 shows that both components contribute and that their combination is important.
-
The external baselines also strengthen the paper's evaluation. The margin over GaitForeMer is substantial under the shared protocol. The repeated splits and paired bootstrap intervals do reduce my concern about the small test set. The intervals exclude zero for all reported values of . The rebuttal also gives the cohort sizes and the HC/PD test composition.
I have two remaining questions.
-
The authors state in the rebuttal that the -NN graph is built over "all windows." Does this include all held-out HC, PD, and other-disease windows at the same time? If yes, the evaluation is transductive. A subject's score can then depend on the other test subjects. Please state exactly which windows are in the graph. An inductive test should use only the training-HC graph and the current test subject, or attach each test embedding to a fixed training graph.
-
The authors also mention in the rebuttal that is estimated with ridge regression and that is the mean inertia matrix of the training HC subjects. This appears to give a fixed global metric . The paper instead describes a configuration-dependent pullback metric that uses the decoder Jacobian and . Please explain this difference. Also separate the effect of the fixed anisotropic metric from the effect of graph shortest paths. Please state the number of random splits used for the reported mean and standard deviation.
If the graph does not introduce problematic test-set dependence, I will consider raising my rating. Thank you.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
In this paper, the authors study the problem of learning motion representations for clinical gait analysis, focusing on Parkinson's disease. The paper is motivated by the observation that clinical motion datasets are often small, making purely data-driven representations prone to overfitting. Acknowledging that human gait follows the common biomechanical principles, the authors encode this physical structure directly into the learned representation.
Since Euclidean geometry treats all directions of motion equally while human’s articulated motion exhibits direction-dependent mechanical costs, the authors argue that the learned representation should preserve an inertia-induced geometry instead of Euclidean geometry. Based on this idea, they propose REINS, a representation learning framework built upon the pretrained PhysPT [1] model, where the Euler-Lagrange consistency loss is replaced with an inertia-consistent reconstruction loss while the remaining objectives are retained.
The proposed method is evaluated by fine-tuning a pretrained PhysPT model on the CARE-PD benchmark and comparing it with data-driven Euclidean and physics-supervised Euclidean baselines. The experimental evaluation includes healthy-control versus Parkinson's disease discrimination, data-scarcity experiments, and zero-shot severity correlation across external cohorts. The proposed method consistently outperforms both Euclidean baselines in HC-vs.-PD discrimination and maintains this advantage under reduced training data and across external cohorts.
[1] Yufei Zhang, Jeffrey O Kephart, Zijun Cui, and Qiang Ji. Physpt: Physics-aware pretrained transformer forestimating human dynamics from monocular videos. In Proceedings of the IEEE/CVF Conferenceon Computer Vision and Pattern Recognition, pages 2305–2317, 2024.
Strengths and weaknesses
Strengths
The paper presents a clear and well motivated formulation that connects established inertia-induced Riemannian geometry concepts with motion representation learning for clinical gait analysis, especially Parkinson disease.
The experiments are comprehensive, covering Parkinson's disease discrimination, data-scarcity, and cross-cohort generalization, with consistent improvements over Euclidean baselines.
Weaknesses
While the application to clinical gait analysis is interesting, the methodological novelty appears somewhat limited, as the framework mainly extends the existing PhysPT architecture [1] and builds upon Riemannian geometry concepts that have been previously explored in related areas such as robotics and motion learning [2].
The paper motivates replacing Euclidean geometry but provides limited explaination for why inertia is the most appropriate biomechanical quantity compared to other physical priors, such as joint torques and inverse dynamics (e.g., [3]) or musculoskeletal models (e.g., [4]).
[2] Noé Jaquier, Leonel Rozo, and Sylvain Calinon. Geometry-Aware Robot Learning with Riemannian Manifolds: A Survey. IEEE Robotics & Automation Magazine, 2022.
[3] Xinpeng Liu, Junxuan Liang, Zili Lin, Haowen Hou, Yong-Lu Li, and Cewu Lu. ImDy: Human Inverse Dynamics from Imitated Observations. International Conference on Learning Representations (ICLR), 2025.
[4] Jie Zhang, Yihui Zhao, Fergus Shone, Zhenhong Li, Alejandro F. Frangi, Shengquan Xie, and Zhi-Qiang Zhang. Physics-Informed Deep Learning for Musculoskeletal Modeling: Predicting Muscle Forces and Joint Kinematics From Surface EMG. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2023.
Questions
1, The paper provides a convincing motivation for replacing Euclidean geometry. However, why was the inertia matrix chosen over other attributes discussed (e.g., joint torques or inverse dynamics) for defining the latent geometry?
2, The manuscript provides limited details on the geodesic computation (e.g., k-NN graph construction, choice of k, edge weights). Could the authors clarify these implementation details?
3, I noticed an unresolved cross-reference ("Section ??") around line 174. Is this simply a formatting issue?
Limitations
yes
Final justification
We thank the authors for their detailed rebuttal. The additional discussion on the choice of the inertia matrix and the expanded description of the geodesic computation satisfactorily address my questions and would strengthen the manuscript if incorporated into the final version. I also appreciate the additional ablation study clarifying the effects of the geometry and reconstruction loss. However, while these clarifications improve the presentation and support the proposed method, my assessment of the paper's methodological novelty remains unchanged, as I still view the overall framework as primarily extending the existing PhysPT architecture with established inertia-induced Riemannian geometry concepts. Overall, I find the paper technically sound and empirically well evaluated, but the methodological contribution is, in my opinion, not sufficiently strong to warrant a higher recommendation. Therefore, I maintain my rating of 4: Borderline accept.
Formatting concerns
The manuscript contains an unresolved internal cross-reference ("Section ??", around line 174), which should be corrected.
3 comments
Rebuttal
We thank Reviewer 6qUG for the careful reading and for the specific, actionable suggestions. We respond to each point below.
- Limited methodological novelty
We agree the two ingredients are established, and we do not claim either as new. What we claim is
(i) using the inertia-induced geometry as the representation space for clinical gait phenotyping, rather than as a post-hoc regularizer on reconstruction, and
(ii) the component-level isolation of where the discriminative signal comes from
Subject-level HC vs PD AUROC at K=20 (95% CI).
| Fine-tuning | Euclidean | J^T J geodesic | J^T M J geodesic |
|---|---|---|---|
| Without L_rec (D) | 0.5167 [0.3167, 0.7125] | 0.5500 [0.3542, 0.7417] | 0.5833 [0.3875, 0.7667] |
| With L_rec (F) | 0.6208 [0.4250, 0.8000] | 0.7292 [0.5500, 0.8792] | 0.8958 [0.7708, 0.9792] |
- Choice of Inertia Matrix (Responding to Weakness1 and Question1)
(i) Structurally, a Riemannian metric requires a symmetric positive-definite bilinear form on velocities. The kinetic energy T = 1/2 q_dot^T M(q) q_dot is positive for any nonzero q_dot, so M(q) is symmetric positive-definite by construction and defines a metric on configuration space directly (Sec 3.2; [5]). Joint torques are generalized forces, i.e. elements of the cotangent space, and inverse dynamics is a map from (q, q_dot, q_ddot) to torques. Neither defines a metric on configuration space without introducing an additional, non-canonical weighting.
[5] Arnold, Vladimir Igorevich, Karen Vogtmann, and Alan Weinstein. Mathematical methods of classical mechanics. Vol. 60. New York: Springer, 1989.
(ii) In terms of observability, M(q) is determined by segment geometry and the kinematic chain, so it is computed in closed form from pose alone. Torques additionally require contact wrenches: classical inverse dynamics needs force plates, and the data-driven alternative [3] obtains torques from a solver trained on simulated dynamics. A torque-based metric would therefore inherit an estimator, which conflicts with our premise that the prior is fixed by mechanics and independent of training data. Musculoskeletal modeling [4] requires surface EMG, which CARE-PD does not provide. We will state this explicitly in Sec 3.2 (Mechanical Preliminaries).
- Clarifications on geodesic computation details (Responding to Question 2)
We will expand Sec 3.5 (Anomaly Detection via Inertia-Induced Distance) with the full scoring procedure as follows: Latents are reduced by PCA (0.95 variance) and the leading component, which corresponds to global translation along the walking direction, is removed. The pullback map J from latent to pose space is fitted by ridge regression on the training-HC windows, giving the metric G = J^T M J with M the training-HC mean inertia matrix. We build a k-NN graph with k=20 over all windows, weight each edge by its length under G, and run multi-source Dijkstra with sources restricted to training-HC windows. A window's score is the shortest-path length to the nearest source, and a subject’s score is the median over their windows.
- Broken Cross-reference (Responding to Question 3)
The two "Section ??" references should’ve pointed to Sec 3.4 (Learning a Latent Embedding). We apologize for the typo and will correct this formatting issue.
We thank the authors for the detailed rebuttal and have considered each response. (1) We appreciate the clarification on the intended methodological contribution and the additional ablation isolating the effects of the geometry and reconstruction loss. We acknowledge the distinction the authors make regarding the proposed representation space. However, our assessment of the paper's methodological novelty remains unchanged, as we still view the overall framework as primarily extending the existing PhysPT architecture using established inertia-induced Riemannian geometry concepts. (2) The explanation for choosing the inertia matrix over other biomechanical quantities satisfactorily addresses our question. We encourage the authors to incorporate this discussion into the manuscript. (3) The added details on the geodesic computation sufficiently clarify the implementation and should be included in the paper for reproducibility. (4) Thank you for correcting the broken cross-reference. We appreciate the clarifications provided in the rebuttal. While they improve the presentation of the work, our overall assessment remains unchanged. We maintain our rating of 4: Borderline accept.
We thank the reviewer for carefully considering our rebuttal. We appreciate that the rationale for choosing the inertia matrix and the details of the geodesic computation are now clear, and we will incorporate these into the manuscript.
We also understand the remaining reservation regarding methodological novelty and acknowledge that the underlying ingredients are established. We appreciate the reviewer's recognition of the distinction regarding the proposed representation space and will position our contribution more precisely at the level of formulation: using the mechanically determined inertia geometry, computed directly from the body model and pose, to structure a learned representation and its geodesic readout for clinical gait phenotyping.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We thank the AC and the reviewers for the follow-up.
Reviewer 2Efi confirmed that the 3x2 ablation, the confidence intervals and the split variability address their Major Weaknesses 1 and 2. We have also supplied the protocol behind the external baselines.
Reviewer 6qUG confirmed that the justification for the inertia matrix and the geodesic implementation details are now clear. We will move both into the final manuscript.
Reviewer NdY6 raised two follow-up questions after our rebuttal, which we answered as follows. (1) The k-NN graph in the submitted results contained all windows, which makes the evaluation transductive. We reran it inductively, with the graph restricted to the training healthy controls plus one test subject at a time, and the result changes by at most 0.0127 AUROC. (2) Separately, Sec 3.5 describes a pointwise pullback metric while the submitted numbers were computed with a constant approximation of it. We apologise for the inconsistency. We have now evaluated the pointwise metric: it differs from the approximation by at most 0.0217 AUROC, and is three orders of magnitude more expensive to construct. The revision will report the pointwise metric throughout and describe the scoring procedure in full.