QUTCC: Quantile Uncertainty Training and Conformal Calibration for Imaging Inverse Problems
Cassandra Tong Ye, Shamus Li, Tyler King, Kristina Monakhova
NeurIPS 2026
TL;DR. We propose QUTCC, a U-Net architecture with a quantile embedding that learns a full conditional quantile distribution during training, and then leverages this non-linear, learned function for spatially-adaptive conformal calibration.
Abstract. While deep learning offers tremendous promise for scientific and medical imaging, any failures and hallucinations (predictions that do not coincide with reality) are hard to pinpoint and can have serious downstream consequences. Uncertainty estimation techniques, such as conformal prediction, can help by predicting statistically valid error bars for a model's prediction. However, popular conformal prediction methods were not designed for high-dimensional image-valued problems and do not take into account spatial correlations within an image during conformal calibration, resulting in larger-than-necessary uncertainty intervals. We propose a practical simultaneous quantile regression method that enables non-linear, spatially-adaptive scaling during conformal calibration. Our method, QUTCC uses a U-Net architecture with a quantile embedding to learn a full conditional quantile distribution during training, and then leverages this non-linear, learned function for spatially-adaptive conformal calibration. At test time, our method can efficiently estimate uncertainty intervals with pixel-marginal coverage guarantees. In addition, QUTCC can also predict pixel-wise conditional probability density estimates without any built-in distributional assumptions. We evaluate our method on several denoising problems, accelerated magnetic resonance imaging, and quantitative phase microscopy. Our method consistently produces tighter uncertainty intervals than prior conformal methods at the same coverage level, can predict plausible conditional distributions for different tasks, and in some cases, high-uncertainty regions can help us locate hallucinations in a model's prediction.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:47 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper introduces QUTCC, a quantile‑conditioned U‑Net with conformal calibration for imaging inverse problems, enabling spatially adaptive uncertainty intervals and pixel‑wise conditional PDF estimation. Reviewers appreciated the method’s conceptual clarity, efficiency, and versatility, noting tighter intervals and practical integration with conformal prediction. However, they raised concerns about variable gains across tasks, limited quantitative validation of recovered PDFs, unclear attribution of improvements to quantile conditioning versus calibration, underexplored failure cases, and evaluation metrics that focus mainly on interval size without calibration plots or likelihood scores. Overall, the work is seen as technically solid and original, but with incremental novelty and incomplete experimental validation. In the rebuttal phase, the authors' responses well addressed the concerns, and two reviewers raised score to 5. The overall ratings are towards accept. Please include these revisions and check the citation mentioned in "Citation Checker " in the final version.
Final justification
The reviewers have some concerns about model validations, improvements analysis, etc. In the rebuttal phase, the authors' responses well addressed the concerns, and two reviewers raised score to 5. The overall ratings are towards accept.
Read meta-review
Meta-review
The paper introduces QUTCC, a quantile‑conditioned U‑Net with conformal calibration for imaging inverse problems, enabling spatially adaptive uncertainty intervals and pixel‑wise conditional PDF estimation. Reviewers appreciated the method’s conceptual clarity, efficiency, and versatility, noting tighter intervals and practical integration with conformal prediction. However, they raised concerns about variable gains across tasks, limited quantitative validation of recovered PDFs, unclear attribution of improvements to quantile conditioning versus calibration, underexplored failure cases, and evaluation metrics that focus mainly on interval size without calibration plots or likelihood scores. Overall, the work is seen as technically solid and original, but with incremental novelty and incomplete experimental validation. In the rebuttal phase, the authors' responses well addressed the concerns, and two reviewers raised score to 5. The overall ratings are towards accept. Please include these revisions and check the citation mentioned in "Citation Checker " in the final version.
Final justification
The reviewers have some concerns about model validations, improvements analysis, etc. In the rebuttal phase, the authors' responses well addressed the concerns, and two reviewers raised score to 5. The overall ratings are towards accept.
2 comments
Summary of Discussion Period
We thank the AC and reviewers for their constructive engagement throughout the discussion period. Below we summarize the main questions raised and our responses.
Reviewer 6Kwx:
- When QUTCC is most beneficial: QUTCC's advantage over Im2Im's global scalar and K-RCPS's partition-based scalars depends on the degree of spatial variation in the optimal per-pixel interval width. QUTCC adapts continuously to local image content, whereas K-RCPS is limited by its partition count. Across four MRI acceleration factors, QUTCC's gains increased with acceleration, consistent with greater spatially varying uncertainty. We will include this analysis in the revision.
- Performance across tasks: QUTCC achieves the largest gains on Poisson noise because signal-dependent noise produces highly spatially varying interval widths. For real noise, the smaller improvement reflects limited diversity in the fixed training set, particularly underrepresented high-intensity pixels, rather than calibration. We will note this limitation.
- Model vs. calibration: Calibrating QUTCC using the Im2Im procedure produced tighter intervals on Gaussian, Poisson, and real noise, and comparable results on QPI, indicating that both the architecture and quantile-space calibration contribute.
- PDF accuracy: We added a linear-Gaussian toy problem with a known posterior, comparing QUTCC against MC-Dropout and Deep Ensembles using the same backbone. QUTCC achieved the lowest KL divergence and Wasserstein distance with a single model and two forward passes. This will be added as direct PDF validation.
Summary: The reviewer states that the rebuttal addressed their major concerns and that they will update the score at the beginning of the AC/reviewer discussion period and ensure the increased score is reflected in the discussion.
Reviewer RE4R:
- Real-noise interval lengths: We clarified that the larger intervals for high-intensity pixels arise from limited training diversity rather than calibration, as these pixels are underrepresented in the fixed real-noise dataset. We will acknowledge this limitation.
- Joint miscoverage: Under monotonicity, lower- and upper-tail violations are disjoint, so per-pixel miscoverage is exactly α/2 + α/2 = α. Quantile crossings, which would violate this assumption, are rare (Appendix Table 3b).
- Pinball loss vs. quantile conditioning: The requested experiment is already in the submission. The Im2Im baseline in Table 1 is Im2Im-Deep trained with pinball loss at fixed quantiles (0.05, 0.95), calibrated with Im2Im scaling, at matched architecture and depth (footnote 4, p. 7). QUTCC still yields tighter intervals, so the conditioning is doing real work. We will state this more explicitly in the revision.
- Extreme calibrated quantiles: Risk remained controlled across all settings tested despite high q_hi. For very small calibration sets or very small α, control could fail as q saturates near 1. This is something we will acknowledge in the revision.
Reviewer K6Yy:
- Spatial correlations: Our guarantee is per-pixel marginal, but spatial information enters through the attention U-Net, which maps shared calibrated quantiles to spatially varying interval widths using local context. Unlike Im2Im's single scalar or K-RCPS's fixed partitions, the effective scaling adapts continuously across the image. We will clarify this to avoid overclaiming.
- Largest/smallest valid quantiles: We clarified that selecting the largest/smallest valid calibrated quantiles follows standard conformal calibration practice.
- Epistemic vs. aleatoric uncertainty: Conformal prediction does not distinguish uncertainty sources; instead, all sources are jointly captured within a distribution-free coverage guarantee. We will clarify this.
- Interval width and calibration: Since all methods are calibrated to the same target coverage (α = 0.1), interval width is the relevant measure of informativeness. Appendix Table 6 confirms empirical coverage, and additional MRI calibration experiments at α = 0.1, 0.2, 0.3, and 0.4 achieved empirical risks of 0.10 ± 0.03, 0.20 ± 0.04, 0.30 ± 0.04, and 0.40 ± 0.04, respectively. We will include these results.
Summary: The reviewer stated that our explanations made sense and is happy with our responses to their questions.
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 2/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 4/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors present a novel approach to deriving calibrated per-pixel uncertainty intervals for image2image problems. The method works by training a UNet to take the input image as well as a quantile parameters as input. The goal of the network is then to correctly predict the quantile. After training the network can be executed multiple times to predict arbitrary quantiles for an image. The authors present an additional post-hoc calibration approach that finds improved input quantile values for the network to produce a desired calibrated uncertainty interval. The method can then also be used, to produce a calibrated per-pixel probability density. The method is then compared against a number of baselines.
Strengths and weaknesses
Strengths
-
This is a novel, elegant and original approach to producing calibrated uncertainty intervals.
-
I believe quantifiable uncertainty estimates are enormously important in order to enable quantitative deep learning in scientific image analysis.
-
The authors did comprehensive experiments on a number of datasets and baselines. For those metrics the authors choose for evaluation they did a thorough job.
Weaknesses
- The authors evaluate the method mainly by comparing the size of the predicted intervals, assuming that smaller intervals are better. However, this is not necessarily the case. I would believe that calibration plots or a quantitative calibration error would be adequate to correctly judge the quality of the predicted intervals. For example, for an ideally calibrated 5% quantile, 5% of GT values should be smaller. This can be repeated for multiple intervals to make a calibration plot. Another sensible metric to check the predicted per-pixel distributions would be calculating the log-likelihood of the GT value according to predicted PDF. This corresponds to the logarithmic score (a proper scoring rule) and allows for the comparison between different methods.
Final recommendation
I believe this is very good, meaningful and original contribution, which unfortunately in the current version seems to have shortcomings regarding evaluation. I am happy to increase my score if the questions regarding evaluation metrics are clarified. If the evaluation is not clarified, I may have to reduce it.
Questions
41: “While prior methods use a linear, constant scaling to obtain calibrated uncertainty intervals and ignore spatial correlations in high-dimensional imaging data, our approach leverages a learned, nonlinear scaling that better captures the underlying distribution of such data.“
It is not clear how the proposed method handles high dimensional data respecting the correlations between pixels. As far as I understand the method the calibration is still done per pixel, based on the marginals, no?
In equation 5 and Alg. 1, why is the problem formulated as finding the largest/smallest q that keeps the miscoverage below the target, instead of just trying to find the q that brings the miscoverage closest to alpha?
Regarding the baselines, are MC-Dropout and ensemble methods not for estimating epistemic uncertainty? Is the proposed method not for aleatoric uncertainty? Or does it capture both? Can the authors please comment on this?
“Our method achieves smaller uncertainty intervals on five imaging inverse problems than prior conformal methods and competitive performance with MC-Dropout and Deep Ensembles at a fraction of the time and compute cost” Is this necessarily good, that the predicted interval is smaller? Ultimately, it’s important that it is the correct interval.
Limitations
Yes
Final justification
I believe all my concerns have been addressed and increased my rating.
Formatting concerns
NA
5 comments
Rebuttal
We are pleased that the reviewer agrees that quantifiable uncertainty estimates are extremely important for deep learning in scientific imaging and that our work offers an original method for doing so. We address the questions brought up in detail below.
Q1. Does QUTCC's learned nonlinear scaling actually capture spatial correlation? We thank the reviewer for this question, the reviewer is correct that our coverage guarantee is per-pixel marginal, and we do not claim to model or certify the joint distribution across pixels. To be precise about what QUTCC does and does not do. What we do not provide is joint or spatially-structured coverage. What we do provide, and what distinguishes us from prior conformal methods, is a modeling and calibration scheme that together yield spatially varying interval widths. The distinction is where spatial information enters. Im2Im calibrates a single global scalar λ applied identically to every pixel, and K-RCPS calibrates K scalars over a fixed, image-independent partition. In QUTCC, the calibrated quantile bounds (q_lo, q_hi) are shared across the image, but they are mapped to pixel-wise interval widths through the network f_θ(y, q), an attention U-Net whose prediction at each pixel depends on the surrounding image content via its receptive field and attention layers. As a result, the effective per-pixel scaling is non-uniform and adapts to local image structure, even though only two global parameters are calibrated. We visualize this in Fig. 2: the Im2Im scaling map is a single constant, the K-RCPS map takes K distinct values over a fixed, image-independent partition, whereas QUTCC varies spatially with image features.
Q2: Why is the problem formulated as finding the largest/smallest q that keeps the miscoverage below the target, instead of just trying to find the q that brings the miscoverage closest to alpha? Regarding Eq. 5 and Alg. 1: selecting the largest/smallest q that keeps miscoverage at or below target is standard in conformal calibration [1]. For example, for a calibrated lower 5th-percentile bound with coverage guarantees, conformal calibration guarantees that at most 5% of ground-truth pixels will fall underneath this bound. Raising the lower quantile q_lo raises the bound, so more pixels fall beneath it and miscoverage increases, so we want the largest q_lo whose miscoverage is still ≤ 5%. Because miscoverage is a step function of q, the calibration set rarely lands on 5% exactly: adjacent quantiles might give 4.7% and 5.2%, straddling the target. Our rule takes 4.7% (valid, slightly conservative). Choosing the q closest in absolute value would instead take 5.2% whenever it is numerically nearer, a marginally tighter interval that exceeds the target and forfeits the coverage guarantee.
Q3. Does QUTCC capture epistemic and/or aleatoric uncertainty The reviewer is correct that MC-Dropout and Deep Ensembles primarily estimate epistemic uncertainty. We include them as baselines for thoroughness, and to compare against other widely-used UQ methods that practitioners might reach for. The reviewer raises an important question regarding the interpretation of QUTCC’s uncertainty estimates, specifically, whether it is epistemic or aleatoric. Conformal methods, like QUTCC, predict heuristic notions of uncertainty, meaning that it does not decompose uncertainty into aleatoric and epistemic components, by design. As a distribution-free framework, conformal methods treat all sources of uncertainty as entangled within a single calibrated guarantee, and our method inherits this property. Because our approach makes no distributional assumptions about the underlying noise or model, it provides valid uncertainty bounds regardless of the specific error sources present. This is the general goal of most conformal methods that predict uncertainty across a range of applications [2-4].
Q4. Are smaller uncertainty intervals advantageous We thank the reviewer for raising this point. All interval widths in Table 1 are conformally calibrated to the same target coverage (α = 0.1), i.e. each interval is guaranteed to contain at least 90% of ground-truth pixels. With coverage fixed across all methods, interval size is a meaningful comparison; a tighter interval at equal coverage is more informative. Furthermore, in Table 6 of the Appendix, we report the empirical risk of all the methods and show that all methods empirically satisfy the coverage guarantee.
[1] Angelopoulos, Anastasios N., and Stephen Bates. "A gentle introduction to conformal prediction and distribution-free uncertainty quantification." arXiv preprint arXiv:2107.07511 (2021).
[2] Angelopoulos, Anastasios N., et al.. Foundations and Trends in Machine Learning 16.4 (2023): 494-591.
[3] Portela, Alberto, et al. PLoS computational biology 21.5 (2025): e1013098.
[4] Lindemann, Lars, et al. IEEE Robotics and Automation Letters 8.8 (2023): 5116-5123.
Follow up
Thank you for the clarification regarding evaluation by interval size. This should be included in the final version of the manuscript, I believe. That being said, would a calibration plot not still be insightful? Or is there an argument that it adds nothing beyond the existing evaluation? Of this, I am currently not yet convinced. Could this be added to the supplement?
We thank the reviewer for this comment. In our results section, we state that all methods are calibrated to the same target risk: “For fair comparison, all methods are conformally calibrated to the same target coverage with α = 0.1.” We also report the resulting empirical risks alongside the mean interval lengths in Table 6. We are happy to clarify this point further in the revised paper.
The reviewer's suggestion to include a calibration plot is valuable. To provide additional reassurance that the calibration behaves as expected across different target risk levels, we evaluated one of our models, MRI, with α = 0.1, 0.2, 0.3, and 0.4. After conformal calibration, the empirical test risks were 0.10 ± 0.03, 0.20 ± 0.04, 0.30 ± 0.04, and 0.40 ± 0.04, respectively, closely matching the desired target risks.
We chose not to include a calibration plot because the purpose of conformal calibration is precisely to adjust the prediction intervals so that they satisfy the desired coverage (or risk) guarantee. The intervals produced by the underlying methods before calibration are heuristic and are not expected to correspond to the nominal quantiles. After calibration, all methods are calibrated to the same target risk, making interval length the primary quantity that differentiates performance. For this reason, we focused our evaluation on interval length between methods.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
QUTCC trains a single U-Net conditioned on a continuous quantile parameter q \in (0,1) using pinball loss, then performs RCPS-style conformal calibration over the quantile conditioning inputs for the lower and upper bounds rather than a global scalar. This makes the method spatial adaptive unlike Im2Im. Furthermore, unlike K-RCPS which calibrates one number or K group-wise parameters, the network's own conditioning in QUTCC is the calibration target, giving per-pixel interval widths that depend on image content. A secondary contribution is pixel-wise conditional PDF estimation via finite differences across queried quantile levels. Experiments cover five imaging inverse problems: accelerated MRI, quantitative phase imaging (QPI), and denoising under real, Gaussian, and Poisson noise.
Strengths and weaknesses
STRENGTHS: The core idea is clean and well-motivated. Im2Im calibrates a single scalar λ; K-RCPS calibrates K parameters over a fixed image partition. QUTCC recasts calibration as finding (qlo, qhi) such that the network's own predictions satisfy coverage, which is a natural move once you have a quantile-conditioned network and sidesteps the need to design any partition heuristic. Table 1 shows QUTCC achieving the tightest or second-tightest stratified intervals across most intensity bins and tasks, and table 6 confirms it has the smallest mean interval length among conformal methods on all five tasks. Two forward passes at inference is a reasonable cost: MC-Dropout requires 28-47x more compute per image and Deep Ensembles require ~10x more training time (tables 7-8). For the conformal setting (single model, no posterior sampling), QUTCC's efficiency profile is good. The ablation on quantile embedding placement (table 5) is one of the stronger ablations I've seen in a paper of this type. Testing seven configurations (encoder-only, decoder-only, bottleneck-only, etc.) and showing that embedding at all scales consistently beats the alternatives gives a concrete answer to what would otherwise be a design choice left unjustified. The result (that restricting to early layers makes the coverage collapse, while restricting to the bottleneck gives valid but unnecessarily wide intervals) makes intuitive sense and is worth knowing. The PDF estimation side of the paper (Section 3.3) is a nice plus, with real value. Recovering p(x|y) at each pixel from finite differences of the quantile function is not new in the 1D setting, but applying it to image regression and conformally calibrating multiple quantile pairs to get a calibrated density estimate is novel enough to be interesting. Figure 5 shows the PDFs behave correctly under Gaussian and Poisson noise regimes, which is reassuring.
WEAKNESSES:
- Some failures go undiscussed. On MRI, the interval length differences between QUTCC and Im2Im-Deep are small enough that the confidence intervals overlap (e.g., high-intensity bin: 0.136 +- 0.022 vs. 0.140 +- 0.019). On the Real Noise task at the 0.80-1.00 intensity bin, QUTCC (0.286 +- 0.025) is substantially worse than K-RCPS (0.197 ± 0.014), a 45% wider interval. This is a notable failure case that deserves a sentence of explanation, not just a table entry.
- The joint coverage guarantee rests on a union bound that is not analyzed. Upper and lower bounds are calibrated independently at α/2 each, and the paper asserts this yields α joint miscoverage. That follows from the union bound, but the union bound is conservative when the two tail errors are positively correlated, as they will be under symmetric noise. How loose is this in practice? table 6 shows total risk values well below 0.1 for many methods, which suggests the bound is leaving coverage slack on the table. The paper could at minimum measure the empirical joint miscoverage and compare it to 1 − α, but this analysis is absent.
- The PDF estimation has no formal guarantees and numerical stability is not discussed. Calibrating individual quantile pairs provides marginal coverage at each queried level. What this implies for the recovered PDF is unclear. A conformally calibrated density is a stronger claim than a collection of calibrated quantiles, and the paper does not state, or prove, what guarantees (if any) the returned PDF carries. Separately, Eq. 7 computes ∂f/∂q by finite differences. When the quantile function is flat (common in low-noise, low-intensity regions where the predicted image barely changes with q), this derivative approaches zero and its inverse blows up. Figure 12 shows that adding more quantile queries stabilizes the PDF shape, but stability against numerical blow-up in flat regions is not examined.
- The authors correctly include Im2Im-Deep (same U-Net architecture) as the primary conformal baseline and show in table 2 that mean prediction quality (MSE, SSIM, PSNR, LPIPS) is similar across methods. However, training with pinball loss at randomly sampled quantiles is a different regularization regime than training with MSE. The right ablation would be: train the same U-Net with pinball loss at fixed quantiles (0.05, 0.95) and calibrate with Im2Im-style scaling. If this recovers most of the gain, the win comes from the loss function rather than the quantile conditioning mechanism. If it doesn't, the conditioning is doing real work. That experiment is missing.
- Several imaging modalities the paper targets (blind denoising, compressed sensing without matched training data) are now routinely handled by self-supervised methods. The paper acknowledges this in one sentence. A brief discussion of whether a self-supervised loss could substitute for paired pinball training, or at least which tasks in the benchmark are practically limited by this, would give readers a clearer sense of scope.
Questions
-
QUTCC's interval length at the 0.80-1.00 bin for real noise is 0.286 vs K-RCPS's 0.197 in table 1. What drives this? Is it a calibration artifact (qhi pushed to near 1.0 to satisfy coverage, as in table 4 for Poisson where qhi = 0.9999995), and if so, does post-hoc inspection of the calibrated qhi values explain the difference? A clear answer here would either validate the method's reliability across tasks or reveal a systematic failure mode. This would raise my score if you can show the failure is understood and bounded.
-
Table 6 shows total risk well below 0.1 for QUTCC in most tasks (e.g., Gaussian: 0.090, QPI: 0.098), suggesting the independent alpha/2 calibration is conservative. Did you measure the empirical joint miscoverage directly (i.e., the fraction of pixels where both bounds are violated simultaneously)? If the empirical joint miscoverage is much lower than α, that is evidence the union bound is loose and the intervals are wider than necessary. Reporting this number would sharpen the theoretical picture.
-
To confirm the quantile conditioning mechanism is what produces tighter intervals rather than the pinball loss regularization, have you tried training Im2Im-deep with pinball loss at fixed quantiles (0.05 and 0.95) and calibrating with standard Im2Im scaling? This experiment would substantially strengthen the paper's central claim if QUTCC's conditioning outperforms it.
-
Table 4 shows that for Poisson noise, calibration converges to q_hi = 0.9999995. This effectively means the network is being asked to predict the near maximum of the conditional distribution rather than the 95th percentile it was initialized at. Does the network generalize reliably to quantile values this extreme, given that training samples q uniformly from (0,1)? How many training samples fall near the boundary, and is there evidence of degraded quantile predictions there?
Limitations
The authors have adequately addressed the limitations and implications of their work.
Formatting concerns
None.
1 comment
Rebuttal
We thank the reviewer for their constructive comments and thoughtful feedback. We are happy to hear that the reviewer finds the paper’s core idea clean and well-motivated. We directly address all of the concerns and questions below.
Questions
Q1. Longer QUTCC interval lengths (compare to K-RCPS) in 0.80 - 1.00 for real noise The reviewer raises an important point about the gap in performance between QUTCC and K-RCPS in real noise at pixel intensity 0.8 - 1.00. We refer the reviewer to bullet 4 of our response to Reviewer 6Kwx.
Q2. Measuring empirical joint miscoverage for low-risk QUTCC settings We thank the reviewer for this suggestion. First, a clarification on the union bound in our setting. In general, marginal miscoverage rates on the two bounds are not enough to infer the joint miscoverage. However, under a monotonicity assumption for the upper and lower bounds, the events that the ground truth value falls below the lower bound and that the ground truth value falls above the upper bound are disjoint for a single pixel: a pixel value cannot violate both bounds simultaneously. Their joint probability is therefore zero, and the union bound holds with equality: the total per-pixel miscoverage is exactly the sum of the two one-sided rates, (\alpha/2 + \alpha/2 = \alpha). Quantile crossings, which would break this disjointness, are rare and are reported in Appendix Table 3b.
Q3. Im2Im-deep with pinball loss loss fixed at quantiles (0.05 and 0.95) and calibrated with standard Im2Im scaling We thank the reviewer for this note. The reported interval widths of Im2Im in Tbl. 1 is in fact Im2Im-Deep trained with pinball loss to predict fixed upper and lower bounds at 0.05 and 0.95. These bounds are then calibrated using standard Im2Im scaling. We make note of this in footnote 4 on the bottom of page 7: “To ensure that our performance improvements come from our uncertainty quantification technique and not network improvements, we upgrade Im2Im to use the same architecture and depth as QUTCC”. Since, QUTCC still reports smaller interval widths, it demonstrates that the quantile conditioning mechanism is doing real work. Regardless, we apologize if the wording in the results is confusing and will be sure to clarify this in the paper revision.
Q4. Evidence of degraded quantile predictions in high-quantile settings We thank the reviewer for this question. We expect that for Poisson noise (which is trained for 50 epochs with 6,480 draws) to generate 1 point above q_hi = 0.9999995 with probability ~15%. In practice, for all the inverse problem settings that we’ve tried, we can control the risk, despite having high upper/lower qs. Theoretically, if the dataset size is really small or the target alpha is really small, there may be a case where we can no longer control risk as q approaches 1 and cannot get bigger. We acknowledge this limitation and will add a sentence about this to the paper.
Weaknesses
-
Further analysis on the predicted PDF: We provide further evaluations of the accuracy of the PDF prediction in a toy problem. Please refer to Reviewer 1, bullet 3.
-
Could self-supervised loss substitute paired pinball training?: Self-supervised loss cannot be directly used as a substitute for paired pinball training due to self-supervised training’s assumption that the conditional mean is preserved. This assumption does not extend to quantiles, since the more extreme quantiles (0.05, 0.95) are not guaranteed to be preserved, potentially leading to systematically inflated intervals. However, if the noise model is known, then the bias can be corrected. For known noise models such as Gaussian or Poisson, prior work [1, 2] allows for the utilization of self-supervised training via the use of unbiased risk estimators such as SURE [1] or PURE [2] (for Gaussian and Poisson noise, respectively). We plan to address this in the revised version of our paper.
[1]: Everink, Jasper, et al. “Self-supervised Conformal Prediction for Uncertainty Quantification in Imaging Problems”, arXiv preprint arXiv:2502.05127 (2025).
[2]: Amougou, Bernardin, et al. “Self-supervised conformal prediction for uncertainty quantification in Poisson imaging problems”, arXiv preprint arXiv:2502.19194 (2025).
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes a new uncertainty estimation method for image reconstruction/restoration problems. Instead of using a fixed conformal scaling factor to calibrate uncertainty intervals, it trains a quantile-conditioned U-Net that can predict arbitrary quantiles of the output distribution and calibrates those quantiles directly. This allows the method to produce spatially varying uncertainty intervals and estimate approximate pixel-wise probability distributions.
Strengths and weaknesses
Strengths:
-
The proposed method is conceptually simple, easy to implement, and integrates with existing conformal prediction frameworks. The idea of calibrating quantile-conditioned predictions directly is elegant and broadly applicable beyond the specific imaging tasks considered.
-
The proposed method is practical. Modification over standard denoiser/restoration network is minimal. The efficiency of single model conformal approaches is used, and unlike ensemble based uncertainty method, is not burdened with high training/inference computational overhead. This makes this approach favorable for imaging inverse problems, where the inference cost is concerning.
-
The quantile-conditioned framework naturally provides access to the entire conditional quantile function. As a result, QUTCC can estimate a pixel-wise conditional distribution without introducing additional models, distributional assumptions, or inference procedures. This capability comes almost “for free” once arbitrary quantiles can be queried, making the framework more versatile than prior conformal image-regression methods that only produce calibrated intervals.
Weaknesses:
-
The proposed approach generally improves uncertainty interval length relative to existing conformal methods, however, the magnitude of improvement varies substantially across tasks. Specially, gains are larger for Poisson denoising but relatively small for MRI and QPI. It is not clear generally under which conditions under which spatially adaptive quantile calibration provides meaningful benefits. More experiments are required to understand where we expect to see the method provided better performance. For example, there is only one experiment that investigate the noise level, but difference acceleration rates are not considered. While the method is broadly applicable, the improvements are problem-specific (Gain in Poisson Large, in Gaussian Moderate, in MRI tiny, and in QPI small, where in real noise we don't see the trend), and the paper does not fully explain why.
-
The motivation that a global calibration parameter is overly restrictive for image-valued problems is compelling. However, it is less clear whether the observed gains come from exploiting spatial image structure or from the increased flexibility of the learned quantile-conditioned model. Since the calibration procedure ultimately adjusts only two global quantile parameters, the claimed spatial adaptivity needs to be further explained.
-
The paper does not rigorously validate the recovery of posterior probability. The recovered PDFs appear qualitatively reasonable, for example, for Gaussian relatively symmetrical and skewed Poisson distribution, however the evaluation is largely visual and limited. Since the synthetic Gaussian and Poisson experiments provide access to the true underlying distributions, it would be natural to quantitatively assess PDF accuracy using metrics such as KL divergence and/or Wasserstein distance. Thus, it is not clear how accurately the proposed method recovers the true conditional distribution beyond producing plausible visualizations.
-
The proposed method builds upon existing ideas from quantile regression and conformal prediction. The major novelty is in calibrating quantile-conditioning parameters rather than scaling predicted intervals, resulting in a simple extension of prior conformal image-regression methods. The framework is practical and effective, but the contribution is best viewed as an incremental improvement within the existing conformal prediction paradigm rather than a fundamentally new uncertainty estimation framework.
Questions
The improvements vary substantially across tasks, with particularly strong gains on Poisson denoising but relatively modest gains on MRI and QPI. Can the authors provide insight into what properties of an imaging problem make QUTCC most beneficial, and under what conditions one should expect limited improvement over K-RCPS?
To what extent do the improvements come from the quantile-conditioned model itself versus the proposed quantile-space calibration procedure?
The paper demonstrates qualitatively reasonable conditional PDFs for synthetic Gaussian and Poisson noise. Since the underlying distributions are known in these experiments, have the authors considered quantitative evaluations of PDF accuracy (toy problem)?
In the real-noise experiments, QUTCC appears to underperform K-RCPS in some high-intensity regions. Can the authors provide intuition for this behavior and discuss whether it reflects a limitation of the proposed calibration strategy?
Limitations
yes
Final justification
I have increased my score. Author's rebuttal addressed several of my concerns, including:
- Capability of the method in recovering posterior density. The authors included additional experimental results to support this claim.
- The authors provided additional experimental results and insight addressing several concerns regarding applicability of the method in different inverse problems and setting, including (1) Conditions the proposed method provides the most benefit. (2) Why some inverse problems provide increased performance while others don't. (3) What happens when the inverse problem gets more challenging (higher acceleration rates in MRI). (4) What we expect in the cases of real noise.
Formatting concerns
N/A
6 comments
Rebuttal
We are pleased that the reviewer views our work as clean and well-motivated. We have provided additional explanations and experimental results below to address the reviewer’s questions.
Q1.1. When is QUTCC most beneficial compared to scalar alternatives (Im2Im, K-RCPS)? The benefit of QUTCC over a global- or partition-based scalar is governed by how much the true per-pixel uncertainty varies spatially, i.e., the degree of heteroscedasticity in the ground-truth conditional. A single global λ (Im2Im) or a few partition-wise λ_k (K-RCPS) is sufficient when the ideal interval width is roughly uniform across the image, and increasingly wasteful as that width varies from pixel to pixel. QUTCC's learned, per-pixel effective scaling can exploit exactly this variation.
Q1.2. Why is performance gains stronger on Poisson denoising, but more modest on MRI and QPI? This is consistent with the pattern we observe in Table 1. Poisson noise is signal-dependent (variance scales with intensity), so the optimal interval width differs sharply between dark and bright regions; this is where a scalar is most restrictive and where QUTCC gains the most, consistent with this, the improvement is concentrated in high-intensity bins (Table 1). Additive Gaussian noise is approximately homoscedastic by construction, so a global scalar is already close to optimal and the gain is moderate. For MRI and QPI, the per-pixel uncertainty varies comparatively little across intensity (Table 1 MRI is nearly flat across bins), leaving less spatial structure for QUTCC to recover. QUTCC is most beneficial when per-pixel uncertainty is strongly spatially varying (e.g., signal-dependent noise), and one should expect improvement over K-RCPS to shrink toward parity when the optimal interval width is approximately uniform across the image. However, K-RCPS is fundamentally limited by its partition count (as shown in Fig. 2), its adaptivity is capped by K regardless of how the true uncertainty varies, whereas QUTCC produces a continuous, non-partitioned per-pixel scaling that adapts smoothly to local image content.
Q2. To what extent do the improvements come from the quantile-conditioned model itself versus the proposed quantile-space calibration procedure? To address this question, we take the 5th and 95th quantile from our quantile model and calibrate it using the same procedure as Im2Im. We observe the following mean interval lengths for Gaussian, Poisson, Real Noise, MRI, and QPI - 0.0604, 0.0482, 0.0375, 0.1071, and 0.0631. Our quantile-conditioned, quantile-calibrated model achieves smaller interval widths on Gaussian, Poisson, and Real Noise. Performance on QPI is comparable between the two approaches, while MRI shows slight improvements with Im2Im's calibration. Because the results are mixed, we conclude that both the quantile conditioning of the model and the quantile-space calibration procedure contribute value and are complementary components of our approach. However, as stated in Q.1.1 and Q.1.2, we believe that QUTCC’s learned, per-pixel effective scaling can help when the true per-pixel uncertainty varies spatially.
Q3. Quantitative evaluations of PDF accuracy on a toy problem with known ground-truth distributions We thank the reviewer for raising this important point. We recreate the toy example (Fig. 3) from [1], a linear-Gaussian inverse problem in which the posterior is available in closed form: an MNIST digit is passed through a dense random linear operator with additive Gaussian noise, a per-pixel diagonal Gaussian prior is fit from real MNIST digits, and Bayesian linear-Gaussian conjugacy then gives the exact posterior mean and per-pixel variance, i.e. the true marginal PDF at every pixel. Against this ground truth, we compare 3 methods trained with an identical, lighter-weight U-Net backbone on the same synthetic data: our quantile-regression method (QUTCC), MC-Dropout (dropout kept active at inference, S=50 samples), and a 10-member Deep Ensemble. For every pixel, we compute KL divergence and Wasserstein distance between each method's estimated PDF and the true Gaussian marginal. The mean and standard deviation of the KL divergence for QUTCC, MC-Dropout, and Deep Ensemble are 0.293 ± 0.240, 6.928 ± 3.077, and 0.307 ± 0.046, respectively. The mean and standard deviation of the Wasserstein distance for QUTCC, MC-Dropout, and Deep Ensemble are 0.048 ± 0.042, 0.050 ± 0.040, and 0.054 ± 0.035, respectively. QUTCC achieves the lowest KL divergence and Wasserstein distance among the three methods, indicating that it estimates the underlying PDF more accurately than the other UQ baselines. It also does so at lower computational cost, since it requires training only a single model, unlike Deep Ensembles (which require training multiple independent models) and doesn’t require multiple forward passes at different rates of dropout (unlike MC-Dropout). We will include this quantitative toy-problem evaluation in the revised paper as direct, ground-truth-based validation of PDF accuracy.
Q4: QUTCC underperforming K-RCPS in high-intensity regions for the real noise problem We thank the reviewer for pointing this out. We believe that this behavior stems primarily from a data diversity limitation in the real-noise training/calibration data, rather than a limitation in the calibration procedure itself. In our Gaussian and Poisson denoising experiments, noise is synthesized at each training iteration (each training pair is regenerated with fresh random noise within a specified range every time it is sampled), so the network is effectively exposed to an unbounded number of distinct noisy versions of its 180 base images over training. The real-noise experiments train on a fixed, non-augmented set of captured pairs: the FMD dataset provides 200 unique ground-truth microscopy images, and each ground-truth image in turn has 50 real-noise microscopy samples, making 10,000 pairs total across all epochs. High intensities are also rarer in this data (0.057% of real-noise test pixels vs. 0.091% for Gaussian/Poisson in the 0.80–1.00 bin), so QUTCC's quantile network has the least reliable signal in the intensity range where the gap appears.
[1] Li, Tianao, et al. "ShuffleFlow: Scalable Posterior Inference for Bayesian Inverse Imaging." arXiv preprint arXiv:2606.21099 (2026).
I thank the authors for their responses. The rebuttal addresses several of my concerns well: (1) the added PDF validation experiment, although on a toy problem, strengthens the claim about probability density estimation; (2) the explanation for why gains are larger in the Poisson setting is plausible and supported by the signal-dependent nature of the noise; and (3) the discussion of the real-noise results is helpful.
The main concern that remains is when QUTCC is expected to be most beneficial. For example, the authors state that “For MRI and QPI, the per-pixel uncertainty varies comparatively little across intensity (Table 1 MRI is nearly flat across bins), leaving less spatial structure for QUTCC to recover.” Would this conclusion hold for more ill-posed MRI or QPI settings. Base on this justification, we might expect higher MRI acceleration rates or more challenging subsampling masks induce more spatially varying uncertainty, in which case QUTCC could provide larger gains over scalar or partition-based baselines. However, there is no evidence to support this.
We thank the reviewer for this follow up. Following the reviewer's suggestion, we trained both Im2Im and QUTCC across 4 MRI acceleration factors to investigate whether QUTCC provides larger benefits as the reconstruction problem becomes more ill-posed. These experiments were still running at the time of our rebuttal, so we were unable to include them earlier. The results are shown below.
| Acceleration | Im2Im Length | QUTCC Length | Difference (Im2Im − QUTCC) | % Shorter (QUTCC) |
|---|---|---|---|---|
| 4× | 0.1121 | 0.1116 | 0.0005 | 0.45% |
| 8× | 0.1371 | 0.1348 | 0.0023 | 1.68% |
| 12× | 0.1530 | 0.1511 | 0.0019 | 1.24% |
| 16× | 0.1690 | 0.1643 | 0.0047 | 2.78% |
QUTCC's gains generally increase as the MRI acceleration factor increases. This trend is consistent with our hypothesis that higher acceleration factors induce more spatially varying uncertainty, which provides QUTCC's spatially adaptive calibration with more structure to exploit than the global scalar calibration used by Im2Im. We agree that clarifying the regimes in which QUTCC is most beneficial would strengthen the paper, and we will incorporate this discussion into the revised manuscript.
Comments on the paper
1 comment
We thank the reviewers and the AC for the thoughtful feedback and constructive discussion during this rebuttal period. We have responded to each review and added several new analyses, validation studies, and follow-up experiments based on the suggestions and questions raised. In addition, for some questions we have provided detailed explanations and clarifications, which we aim to expand on and incorporate more fully into the revised paper. If time permits before the discussion period ends, we would greatly appreciate any additional feedback or discussion. We are happy to clarify any remaining questions.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We thank the AC for the thoughtful metareview and for recognizing the clarity, efficiency, and versatility of our method. In our rebuttal, we have addressed the key technical concerns raised by the reviewers. Specifically:
We hope these additional analyses and clarifications demonstrate that the reviewers' primary concerns have been addressed and strengthen the empirical validation and practical understanding of QUTCC.