MoBayes: A Modular Bayesian Framework for Separating Reasoning from Language in Conversational Clinical Decision Support
Yusuf Kesmen, Fay Elhassan, Jiayi Ma, Julien Stalhandske, Yena Chang, Alexandra V. Kulinkina, David Sasu, Akhil Arora, Lars Henning Klein, Mary-Anne Hartley
GenAI4Health @ NeurIPS 2026
TL;DR. MoBayes separates language from reasoning, pairing a deterministic Bayesian belief engine with cheap LLM sensors that match or beat frontier standalone LLM doctors at a fraction of the cost.
Abstract. Large language models (LLMs) are increasingly used for conversational clinical decision support, yet they conflate next token prediction with probabilistic decision making. We argue that this conflation reflects an architectural limitation: such systems lack explicit posterior tracking, controllable abstention thresholds, and auditable reasoning chains. We introduce MoBayes, a Modular Bayesian dialogue framework that separates reasoning from language. The LLM acts only as a language interface, parsing patient conversation into structured observations, while a Bayesian module performs probabilistic inference over these observations to update posteriors, select follow-up questions via expected-information-gain and determine when to stop or defer through calibrated decision thresholds. This design enables explicit posterior tracking, controllable selective decision-making, and replaceable population-specific statistical backends without retraining the language model. Across empirical and LLM-generated knowledge bases, MoBayes outperforms standalone frontier LLM doctors, including matched model-family comparisons where inexpensive sensor models paired with MoBayes exceed larger autonomous models at lower cost. The advantage persists under adversarial patient communication styles and across varying diagnostic scenarios. These results suggest that reliable conversational clinical decision support systems should separate probabilistic reasoning from language generation rather than scaling model size alone. Code is available at https://anonymous.4open.science/r/MoBayes/.
From the authors: Yusuf Kesmen · edit · also an author?
Nothing yet.
edit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:45 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
MoBayes argues for a strict architectural separation between natural-language interaction and probabilistic diagnostic reasoning in conversational clinical decision support. The LLM serves only as a language interface, parsing patient utterances into structured evidence triples and verbalizing system-selected features as follow-up questions. The posterior threshold is not merely a post-hoc hyperparameter; it explicitly encodes deployment priorities: lower thresholds favor coverage, whereas higher thresholds favor safety. The controllable abstention mechanism is also practically useful.
The novelty over existing Bayesian–LLM systems such as ACTMED is not sufficiently established. All three reviewers assigned an originality score of 2. Bayesian updating, expected-information-gain question selection, and the modular separation of language from probabilistic reasoning are established ideas; one reviewer noted that ACTMED had already introduced a closely related separation principle. The reasoning model also relies on a strong naive Bayes factorization. Because clinical findings are often correlated, the conditional-independence assumption may double-count evidence, distort posterior probabilities, and lead to suboptimal question selection.
Final justification
The authors have substantially improved the paper during rebuttal by clarifying the novelty of the proposed architecture and adding important experiments on missing-diagnosis cases, knowledge-base robustness, parser reliability, and full benchmark evaluation. These additions provide stronger evidence for the effectiveness and reliability of the framework.
I believe the paper provides a meaningful contribution through its interpretable and modular approach to clinical decision support, and the authors’ responses have sufficiently addressed the major reviewer concerns. Therefore, I recommend acceptance.
Read meta-review
Meta-review
MoBayes argues for a strict architectural separation between natural-language interaction and probabilistic diagnostic reasoning in conversational clinical decision support. The LLM serves only as a language interface, parsing patient utterances into structured evidence triples and verbalizing system-selected features as follow-up questions. The posterior threshold is not merely a post-hoc hyperparameter; it explicitly encodes deployment priorities: lower thresholds favor coverage, whereas higher thresholds favor safety. The controllable abstention mechanism is also practically useful.
The novelty over existing Bayesian–LLM systems such as ACTMED is not sufficiently established. All three reviewers assigned an originality score of 2. Bayesian updating, expected-information-gain question selection, and the modular separation of language from probabilistic reasoning are established ideas; one reviewer noted that ACTMED had already introduced a closely related separation principle. The reasoning model also relies on a strong naive Bayes factorization. Because clinical findings are often correlated, the conditional-independence assumption may double-count evidence, distort posterior probabilities, and lead to suboptimal question selection.
Final justification
The authors have substantially improved the paper during rebuttal by clarifying the novelty of the proposed architecture and adding important experiments on missing-diagnosis cases, knowledge-base robustness, parser reliability, and full benchmark evaluation. These additions provide stronger evidence for the effectiveness and reliability of the framework.
I believe the paper provides a meaningful contribution through its interpretable and modular approach to clinical decision support, and the authors’ responses have sufficiently addressed the major reviewer concerns. Therefore, I recommend acceptance.
1 comment
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper studies the problem of sequential knowledge acquisition in medicine with LLMs. The authors introduce MOBAYES a framework to separate the understanding of the clinical information of the patient from the reasoning about the likelihood of medical decisions. Their framework is not tied to a particular LLM architecture and displays strong performance in clinical diagnosis tasks with reduced costs compared to LLM only baselines.
Strengths and weaknesses
Strengths
Bayesian systems for medical diagnosis using LLMs are a promising and important direction for medical research. The authors demonstrate the performance and cost-effectiveness of their performance on several backbone LLMs. The paper is largely well-written with informative figures and tables.
Weaknesses
While I appreciate the authors intention in highlighting the performance of their model against strong frontier models in Table 2, I feel like it is necessary to include the results for the same models as MOBAYES to isolate the effect of the framework better.
The idea of separating the probabilistic reasoning from the language interface was already introduced in ACTMED (Ruhrberg Estevez et al. NeurIPS 2025) which should be discussed in the introduction and related works sections. The contribution claims regarding the novelty of this aspect need to be changed accordingly.
The datasets used are very small.
The ability to only diagnose diseases that are in the training corpus appears like a major limitation compared to the attractiveness of zero-shot diagnosis with LLMs in other frameworks.
The framework appears to mainly extract features from text and then using Bayesian statistics afterwards which in itself is not very novel. Can the same extraction be used for a downstream model e.g. XGboost with median imputation and if so can the authors please benchmark against this.
Questions
Would it be possible to evaluate the effectiveness of their method on VivaBench (Chiu et al. 2025) which is larger than AgentClinic and designed specifically for sequential diagnosis.
Could the authors please provide more details on the experimental setup in Table 1 since it is not referenced in the text.
Does the AgentClinic-MedQA 50/100 mean that the method was only run on a subset of the dataset? If so how were these patients chosen and why was the full dataset not used.
How is the soft-evidence probability implemented for real-world patients? Also, do baselines receive comparable information?
Can the authors benchmark against other bayesian diagnosis LLM frameworks such as ACTMED.
Can the authors please provide a sensitivity analysis on the number of diseases already present in the knowledge corpus on the diagnostic accuracy of the system.
Limitations
Yes
Final justification
I thank the authors for running the additional experiments, please include them in the final version of the paper. I personally feel this paper sits very much at the borderline and I am uncertain whether to give it a 3 or a 4. However, since most issues were addressed well in the rebuttal and the other 2 reviewers voted accept I will raise my score to 4. There are however a number of remaining limitations that should be discussed extensively in the limitations section.
Formatting concerns
None
3 comments
Rebuttal
Response to Reviewer zMZn
We thank the reviewer for the careful review. For clarity we number the weaknesses (W1–W5) and questions (Q1–Q6) in the order they were raised. The main concern, raised as both W2 and Q5, is originality in view of ACTMED, and we address it first. While both works combine probabilistic reasoning with language models, they belong to different architectural paradigms: ACTMED is a Bayesian Experimental Design (BED) framework, whereas MoBayes enforces a strict separation between language understanding and probabilistic reasoning. We then answer the reviewer's remaining points in order.
A clarification regarding ACTMED and the novelty of our work
ACTMED is an application of Bayesian Experimental Design in a clinical setting. The seminal paper in this line of work is BED-LLM, which predates ACTMED and establishes the mechanism of guiding an LLM with a Bayesian harness. We discuss BED-LLM prominently in our related works section within the hybrid category of our taxonomy (Section 2 and Figure 1a, also in Appendix D). The defining characteristic of this family is that the LLM sits inside the probabilistic reasoning engine. It serves as an oracle that generates patient-state distributions and supplies likelihoods that factor into belief updates.
Our work presents a fundamentally different approach: the LLM serves purely as a language-driven interface. It verbalizes questions and parses responses, but does not participate in the factorization of evidence or next-question selection. We instead rely on a strict separation between the LLM and a Bayesian reasoning engine whose priors and likelihoods are provided by a modular knowledge base.
This knowledge base can be learned from population statistics and/or curated by domain experts. In a hybrid system such as BED-LLM or ACTMED, the LLM fulfils the role of this knowledge base by suggesting probabilities on the fly. This leaves the system vulnerable to hallucinations, ungrounded probability estimates, and extrapolation outside diagnostic guardrails. The public discussion of ACTMED acknowledges this limitation: the reported gains vanish with a 7B open model, and with LLaMA-3.3-70B the sampler produced near-identical draws across prompts and temperatures, which the authors describe as leaving the method inoperable. By comparison, a tiny, inexpensive sensor model is sufficient to drive MoBayes and match or exceed frontier standalone doctors (Table 2; Appendix C.1).
We agree that ACTMED should be cited as a representative medical application of the BED-LLM lineage, but we do not see it as a close competitor.
W1. Extending Table 2
We thank the reviewer for this excellent suggestion. Table 2 currently compares a large standalone model from each family with a smaller sibling used as the MoBayes sensor, for example GPT-5.4 versus GPT-5.4-nano + MoBayes. This asymmetry is deliberate. It hands the autonomous baseline the capacity advantage, so that a MoBayes win cannot be attributed to model size. Despite this handicap, the smaller model coupled to MoBayes performs better, at substantially lower cost.
Following the reviewer's suggestion, we additionally evaluate the model-matched pairings, the small model as a standalone doctor and the large model as a MoBayes sensor, under one identical protocol (DDxPlus PatientSim). For two representative families:
| Configuration | GPT-5.4 (DHS) | Gemini 3.1 (DHS) |
|---|---|---|
| Small standalone | 50.9 | 69.6 |
| Large standalone | 69.4 | 72.6 |
| Small sensor + MoBayes | 83.7 | 86.4 |
| Large sensor + MoBayes | 85.1 | 88.9 |
Small standalone models perform worst; larger standalone models improve but remain below MoBayes; and MoBayes with either the small or the large sensor performs best. The gap between the small and large model also shrinks sharply within MoBayes, to within sampling noise (the two sensors' confidence intervals overlap), supporting the conclusion that the reasoning architecture, rather than scale alone, drives the improvement. The configurations shared with Table 2 reproduce their published values within confidence intervals, so the grid is consistent with the paper. We will add the complete matched table, with confidence intervals and token costs, to the revision.
W3. Dataset size
As each case is a complete multi-turn consultation rather than a static QA item, cohort sizes in the literature are correspondingly modest: AMIE evaluates 149 OSCE scenarios, and MEDDxAgent samples 100 patients per dataset. Our headline comparison likewise uses 100 patients per benchmark. While increasing the dataset size beyond the field standard is a target of future research, we report every headline result with a 95% confidence interval. MoBayes's gains over the strongest baseline in each column are significant under a paired bootstrap test (p < 0.05; Table 1; 95% CIs in Appendix C.13). The findings are reproduced across three benchmarks, two patient simulators, multiple model families, five patient personas, and different knowledge-base sources.
W4. Closed corpus versus zero-shot diagnosis
The closed-world setting confers no unfair advantage. Our closed-world baseline receives the identical candidate set, yet its gap to MoBayes does not close. The evaluations use published benchmark disease universes rather than a disease set constructed by us. We agree that MoBayes cannot diagnose diseases absent from its knowledge base. In a high-stakes setting, however, principled abstention may be preferable to an unvetted open-ended diagnosis. In our target-removal experiment, deleting the correct disease generally prevents MoBayes from crossing its commitment threshold, causing it to abstain rather than fabricate an in-scope answer. By comparison, a hybrid framework would solicit probabilities from an LLM oracle even for rare, unexpected, or confusing evidence. In deployment, the modular knowledge base allows practitioners to integrate new medical knowledge and define the LLM's diagnostic guardrails. Reliably applying a targeted knowledge update to an LLM-based probability surrogate remains an open research question.
W5. Extraction plus Bayes; XGBoost
An XGBoost engine would be a modular variant of MoBayes, not a competitor: the diagnostic engine is swappable by design. Feature extraction is only one component; MoBayes also maintains the disease posterior, incorporates soft evidence, selects questions using expected information gain (EIG), ranks the differential, and decides when to commit or abstain.
EIG requires a generative model to anticipate answers to unasked questions. XGBoost instead models over a completed vector, so an interactive implementation would need our EIG mechanism or another active-feature-acquisition policy. It also requires labelled training rows, which exist for the empirical DDxPlus KB but not the LLM-elicited setting, where MoBayes runs unchanged.
We deliberately use naive Bayes as the simplest sufficient engine. That it suffices is part of the finding.
Q1. VivaBench
We thank the reviewer for the suggestion and will cite VivaBench. It evaluates six standalone frontier LLMs rather than the diagnostic-dialogue systems compared in Table 1. Its interactive protocol includes a dedicated investigation-ordering stage (laboratory and imaging), an action space outside our history-taking setting. We therefore view VivaBench as complementary and will discuss it as future work.
Q2. Table 1 not referenced in the text
The reviewer is correct. A stale cross-reference pointed to an appendix copy of the comparison, leaving Table 1 itself uncited. We will fix this.
Table 1 is our headline comparison across three benchmark settings. It reports Top-1 accuracy, selective accuracy, coverage, DHS, and tokens per case. MoBayes commits when its maximum posterior exceeds and otherwise abstains. Per-system protocols are in Appendix C.14, with bootstrap confidence intervals in Appendix C.13. We will summarize this setup immediately before the table.
Q3. AgentClinic-MedQA 50 and 100
These labels refer to fixed subsets of the 213-case pool. Cases are selected with a fixed seed and weighted by disease frequency; ties are resolved randomly. DDxPlus cases are stratified across diseases. Every system uses exactly the same patients, so comparisons are paired and subsets are not selected separately for different systems. The headline comparison and significance tests use 100 patients; the more expensive model comparisons and ablations use 50. The 100-patient evaluation combines two independent 50-patient samples whose conclusions agree. Running every system and ablation on all 213 cases would require costly multi-turn simulations. This follows prior interactive work, including MEDDxAgent’s fixed-seed sample of 100 patients per dataset. We will clarify this procedure and rationale.
Q4. Soft evidence and information parity
Soft evidence is the parser's confidence over five ordinal labels, read from the patient's own hedging language (Section 3.4). It is not privileged information and works identically for real patients because the labels derive from what the patient says. All systems receive the same utterances, and standalone baselines read the full raw dialogue, a superset of the structured triples our parser extracts.
Q6. Sensitivity to the number of diseases
We ran precisely this analysis. The Disease Scaling Analysis (Appendix C.11) sweeps random DDxPlus subsets with different numbers of diseases (one patient per disease; three seeds). MoBayes Top-1 accuracy remains in the high 70s to mid-80s with no systematic decline as the candidate space grows fourfold. The standalone doctor remains between 34 and 41 throughout. The MoBayes advantage is therefore large and stable.
I thank the authors for their thorough response.
However I would like to see the performance of MoBayes on the full AgentClinic dataset before making a final recommendation as it is not clear to me how the subset was chosen and whether this advantages MoBayes. I agree that AMIE used a small cohort as well but part of that study was to make the dataset and evaluate it with clinicians which limits the size manageable. It is highly unusual to only run a subset of an established benchmark for a new model and raises questions regarding the selection of the subset.
It is not clear to me why VivaBench cannot be used for MoBayes validation as the lab ordering stage can be phrased as history taking for the experimental setup e.g. What was your most recent haemoglobin value etc. MoBayes not being compatible with laboratory testing also seems like a major limitation.
I agree with the authors that their method is novel enough as compared to prior works but I would like to highlight that BED-LLM was published at ICLR 2026, which is after the NeurIPS 2025 ACTMED publication.
I am pleased by the additional results in W1, W4 and W5 as well as Q2, Q4, Q5 and Q6.
We thank the reviewer for the continued engagement and for pushing us on both points. We address the two outstanding items, (i) the full AgentClinic-MedQA evaluation and (ii) VivaBench, and close with a brief note on the ACTMED/BED-LLM chronology.
(i) Full AgentClinic-MedQA evaluation
We scale MoBayes to the complete AgentClinic-MedQA set (213 cases), building on Appendix B.4. We note that the new results are entirely in line with the observations recorded in the original manuscript: The full-set results fall inside the confidence intervals of both previously reported subsets, and the subsets fall inside the confidence interval of the full set.
| Evaluation set | Top-1 | DHS |
|---|---|---|
| Paper, n = 50 | 76.0 [64, 88] | 86.8 [79.0, 93.6] |
| Paper, n = 100 | 70.0 [61, 79] | 83.1 [77.1, 88.5] |
| Full set, n = 213 | 75.1 [68.8, 81.0] | 86.2 [82.1, 89.8] |
The three estimates are statistically indistinguishable, so the case selection procedure discussed in Q3 did not disproportionately advantage MoBayes.
We will report the full-set numbers as the headline AgentClinic result in the revision, retain the subset results only where they support the more expensive model comparisons and ablations.
(ii) VivaBench
We agree that MoBayes is not architecturally restricted to history variables. A laboratory result is simply a feature whose value domain and disease-conditional likelihoods have been defined, and nothing in the posterior update or in EIG selection distinguishes it from a symptom.
VivaBench is a genuinely interesting setting, and we take the suggestion seriously. To our knowledge, the systems we benchmark against have not been evaluated on VivaBench, so a run here cannot position MoBayes against prior work. We therefore read the reviewer's request as asking whether the architecture can operate in a setting of this kind at all. We subsampled 50 cases, constructed a knowledge base based on the pipeline described in Appendix B.4, and ran the system end to end within the harness. No architectural blockers arose.
| Variant | Top-1 | SA | Cov. | DHS |
|---|---|---|---|---|
| MoBayes (staged EIG) | 44 [30, 58] | 58 | 76 | 66 [53, 76] |
On this subsample, MoBayes outperforms the standalone models recorded in VivaBench. However, we want to emphasize that we consider this a feasibility check rather than a full evaluation, and we draw no comparative claim from it.
A full evaluation, together with the required baselines, is interesting future work, as is knowledge base construction at benchmark scale, which we will state as a limitation. We are happy to cite VivaBench and to include this initial experiment in the appendix.
(iii) ACTMED and BED-LLM
We thank the reviewer for the correction on publication chronology, and we accept it: BED-LLM appeared at ICLR 2026, after ACTMED at NeurIPS 2025. We will correct the framing and cite ACTMED accordingly in the related-work section. We are glad the reviewer finds the distinction from prior work sufficient to qualify novelty.
We hope the full-benchmark result addresses the reviewer's principal remaining concern, and that the VivaBench study demonstrates that investigation-stage reasoning is within scope for MoBayes rather than excluded by it. We are happy to answer any further questions during the discussion period.
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes a hybrid dialogue-driven medical decision support system. The authors propose MOBAYES, a modular Bayesian framework that separates the language interface from the reasoning engine. The system design aims at diagnostic reliability, by having all reasoning occur within the probabilistic system (not the LLM), and LLM efficiency by limiting calls to the LLM to 1) human interfacing (language dialogue), and 2) as a last resort for concept parsing. The Bayesian module selects follow-up questions using expected information gain. The system is evaluated on DDxPlus and AgentClinic-MedQA benchmarks against standalone frontier LLMs and other diagnostic-dialogue systems. Results indicate that MOBAYES achieves higher performance than standalone models.
Strengths and weaknesses
I found this paper a pleasure to read. It was organized logically, written with clarify, and figures and tables were informative and easy to navigate. While I suspect the novelty of each component may be low—other authors have demonstrated Bayesian driven dialogue, expected information gain, soft information—the paper puts it all together in a very coherent and effective tool. I think the biggest weakness of the paper is the naive Bayes factorization, which the authors acknowledge
Questions
-
The authors acknowledge that the system cannot exploit volunteered evidence that falls outside the specifically asked question. In a real clinical setting, patients often provide spontaneous, critical information; how would the framework be modified to incorporate this without compromising the strict separation of reasoning and language?
-
The 'LLM-elicited KB' is central to the fair-fight experiments. Given that the Bayesian module's performance is entirely dependent on the accuracy of the conditional likelihoods P(Xf = v | d), how sensitive is the system to noise or inaccuracies in the elicited KB? Was a sensitivity analysis performed to determine the minimum KB precision required to maintain the reported DHS gains?
-
Regarding the closed-world assumption: while the abstention mechanism provides a safety valve, standalone LLMs can potentially identify diseases outside a predefined list. Can the authors provide a quantitative comparison of the 'abstention rate' for truly out-of-distribution (OOD) cases in MOBAYES versus the 'hallucination rate' (incorrectly confident diagnoses) of standalone LLMs for the same OOD cases?
Limitations
I would add the naive-Bayes assumption to the Limitations section in the Conclusion. Other than that I think the authors are honest in the acknowledged limitations of the manuscript.
Final justification
This remains a well written paper. The authors' responses to reviewer comments are reasonable and their modifications are appropriate. The paper remains a technically strong and important paper that should be accepted.
Formatting concerns
I have no paper formatting concerns.
1 comment
Rebuttal
Response to Reviewer ejtg
We thank the reviewer for the careful reading and encouraging assessment. We are glad the paper was a pleasure to read. We respond to the questions below and adopt the suggestion on the limitations section. We responded to the one weakness (W) and three questions (Q) in our rebuttal.
W1. On component novelty and naive Bayes factorization
We agree with the reviewer's interpretation. Our contribution is not a novel Bayesian inference algorithm but an architectural separation of language processing from probabilistic reasoning, together with the orchestration that enables this separation and the controlled experiments that attribute the observed gains to it.
The naive Bayes factorization is a modular, contextualizable probabilistic engine. While we instantiate MoBayes with a naive Bayes factorization, this is one realization of the probabilistic engine rather than a defining architectural choice. As noted in the Methods, richer factorizations can be substituted while preserving the same belief representation, EIG policy, and abstention rule at the cost of more complex inference and a larger KB elicitation budget.
This modularity is particularly valuable for medical deployment. Rather than adapting an LLM by embedding sensitive patient records into the weights or hoping for it to implicitly respect local epidemiology, this probabilistic information can be explicitly incorporated by updating the probabilistic knowledge base. This enables privacy-preserving contextualization while keeping the reasoning process interpretable, auditable, and independent of the language model. It also allows the validated decision space to remain explicit and bounded.
Following the reviewer's suggestion, we will state the naive-Bayes assumption explicitly in the limitations paragraph of the conclusion.
Q1. Incorporating volunteered evidence without compromising the separation
The separation concerns where the probabilistic reasoning occurs, not how much evidence the parser may extract from a single utterance:
The Bayesian engine already accepts an arbitrary set of structured observations. The opening patient statement is processed by a bulk extraction pass, which maps the free text onto multiple schema features in a single step and working successfully.
Extending this to follow-up dialogue is a purely language-side change. No component on the reasoning side needs to be modified.
Concretely, the modified per-turn would be:
- Map the reply to a structured observation (unchanged language parser)
- A binary LLM classification to detect volunteer information (new language-side step)
- Bulk extraction, reusing the existing intake component (unchanged bulk extraction stage, but used in any part, now only in initial intake)
- Belief update (unchanged)
We restricted the current system to single-item parsing on the follow up turns as a conservative robustness and cost choice, which is also in line with the simulators.
Q2. Sensitivity to noise in the KB
We ran a controlled KB noise experiment for this rebuttal. We hold the recorded dialogues of a clean KB run fixed and replay the logged evidence through corrupted copies of the empirical DDxPlus KB.
We deliberately corrupt the empirical KB rather than the LLM-elicited one. The empirical KB is the cleanest available reference, so the injected noise is the only source of likelihood error and the noise level is fully controlled.
The experiment holds the dialogue fixed and perturbs only the knowledge base. For each of 100 PatientSim consultations, we take the recorded evidence trace, observations the parser produced on the clean KB and replay it through the corrupted copies of the emprical DDxPlus KB, recomputing the Bayesian posterior offline with question selection and extraction frozen for no new model call We apply two corruptions at the likelihood layer: multiplicative log-normal noise on the conditional likelihoods P(X_f = v | d) with scale sigma, and random blanking of a fraction rho of (feature, disease) entries to uninformative. We picked the threshold 0.3, held it fixed across all noise levels, averaged DHS over 20 independent noise draws per level.
Mean DHS over 20 noise seeds is as following:
| Sigma | 0 (clean) | 0.1 | 0.25 | 0.5 | 1.0 | 2.0 |
|---|---|---|---|---|---|---|
| DHS | 88.0 | 87.8 | 87.7 | 87.6 | 84.5 | 69.0 |
| Rho | 0 (clean) | 0.1 | 0.25 | 0.75 |
|---|---|---|---|---|
| DHS | 88.0 | 85.9 | 82.1 | 37.1 |
DHS is flat up to sigma 0.5 and tolerates roughly 10% missing retries. In short, the reported gains survive substantial mis-estimation of individual likelihoods provided the KB covers the feature space.
For the other point, the LLM-elicited KB is already a noisy realisation of the same quantities, with an unknown deviation from the truth. So perturbing it further would confound two error sources and the sweep would no longer measure sensitivity to a known amount of noise. To understand the noise behavior of LLM-elicited KB, we have two observations in the paper bound the sensitivity:
- LLM-elicited KB is measurably less informative than empirical KB (per pair KL divergence CDF in Appendix B.4), yet an inexpensive same-family sensor still matches the frontier standalone at a lower focus (Appendix C.1). The reported gains therefore already hold under a noisier KB.
- Two independently elicited KBs (with different models) agree closely on their likelihoods (Pearson r = 0.931, MAE=0.071 in Appendix B.4), and both yields strong DHS, so the result does not backed on one particular elicitation.
Q3. Abstention rate vs hallucination rate on truly OOD cases
We ran exactly this comparison for rebuttal. For each of PatientSim DDxPlus cases, we remove the true disease from the candidate space and rerun the full dialogue, so every committed diagnosis is wrong and the only correct behavior should be doing "abstention". MoBayes arm excludes the disease from priors, likelihoods and EIG space. The standalone arm receives the identical reduced disease list plus an instruction to abstain if no listed disease match. Noting that both uses GPT 5.4 nano, outcomes on the same 50 OOD cases for threshold 0.9:
| Outcome | MoBayes | Standalone |
|---|---|---|
| Abstained | 44 (88%) | 23 (%46) |
| Hallucinated | 6 (12%) | 27 (54%) |
MoBayes is more robust to missing diseases. Standalone commits to a diagnosis even they are not in the list with 54% despite the explicit abstain instruction. This result above is one operating point. Because MoBayes decides this by comparing posterior to a threshold tau, the trade-off is a single tunable parameter, whereas the standalone doctor exposes no comparable knob. Sweeping tau over the same 50 OOD cases, the MoBayes hallucination rate stays below the standalone rate at every threshold, including the most permissive one:
| Threshold | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 0.95 |
|---|---|---|---|---|---|---|
| MoBayes Hallucination (Committed) | 36% | 28% | 26% | 22% | 12% | 12% |
| Standalone Hallucination (Committed) | 54% | 54% | 54% | 54% | 54% | 54% |
The comparison therefore does not rest on a single favorably chosen threshold. We will add this experiment to the appendix.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes MOBAYES, a modular Bayesian framework for conversational clinical decision support. The main idea is to separate language handling from probabilistic reasoning. Instead of asking an LLM to manage the full diagnostic process, the LLM is used only as an interface: it parses patient utterances into structured evidence and verbalizes follow-up questions. The diagnostic reasoning itself is performed by a Bayesian module that maintains posterior probabilities over candidate diseases, selects follow-up questions using expected information gain, and decides whether to commit or abstain using a tunable posterior threshold.
The framework is evaluated on several diagnostic-dialogue benchmarks, including DDxPlus, a history-taking simulator setup, and AgentClinic-MedQA. The authors compare MOBAYES against standalone LLM doctors, prompt-based methods, information-pursuit systems, agent-based systems, and a fine-tuned medical diagnostic model. They report that MOBAYES achieves stronger Diagnostic Harmonic Score on the main DDxPlus settings and remains competitive on AgentClinic-MedQA. They also report that smaller and cheaper LLMs used as MOBAYES sensors can outperform larger standalone LLM doctors, suggesting that the modular architecture rather than model scale is driving the observed advantage.
A second contribution is that by varying a threshold, MOBAYES can move along an accuracy-coverage curve, giving users or deployers more control over when the system provides a diagnosis versus when it defers. The paper also argues that the Bayesian knowledge base can be replaced or adapted without retraining the LLM, which may make the framework more auditable and easier to localize across populations.
Strengths and weaknesses
The paper has a nice clinically relevant motivation. It is reasonable to argue that conversational diagnostic support should not rely entirely on next-token generation for both communication and probabilistic decision-making. The proposed separation between an LLM language layer and an explicit Bayesian reasoning layer is conceptually clean. I also think the paper does a good job explaining why posterior tracking, question selection, and abstention are important for clinical dialogue.
A major strength is the simplicity and interpretability of the architecture. The Bayesian module has a clear state, updates beliefs explicitly, and allows inspection of the evidence trail. This is attractive for clinical decision support, where auditability matters. The threshold-based abstention mechanism is also useful because it gives a natural way to trade coverage against diagnostic certainty without retraining the system.
The empirical results are good too. The paper compares against a broad set of baselines and reports strong performance on DDxPlus-based settings. The cost argument is also compelling. If a smaller LLM can serve as a parsing and verbalization layer while the Bayesian module handles reasoning, then this is a practical alternative to simply scaling the LLM. The LLM-generated knowledge base experiment is also a useful attempt to address whether MOBAYES is benefiting only from access to structured empirical statistics.
The architecture itself is a general pattern applicable beyond clinical dialogue to any closed-world, structured decision-support task, which strengthens my view of the paper's methodological contribution. At the same time, this generality is argued in principle but never demonstrated empirically outside the clinical domain, which I see as a notable gap.
The main limitation is that the evaluation still depends heavily on simulated diagnostic conversations. DDxPlus is synthetic, and the patient interactions come through simulators rather than real patients or clinicians. This makes it difficult to know how well the system would work in messy clinical settings, where patients volunteer extra information, misunderstand questions, give inconsistent histories, or describe symptoms outside the expected schema.
A second weakness is the closed-world assumption. MOBAYES can only diagnose diseases that are in its knowledge base. This is a serious constraint in clinical diagnosis, where the correct diagnosis may not be in the predefined set or where multiple conditions may coexist. The abstention mechanism helps, but the paper should better quantify failure modes when the true disease is missing, when the patient has comorbidities, or when the knowledge base is incomplete.
Also the comparison with standalone LLM doctors is not always fair. Standalone models are open-ended systems, while MOBAYES operates in a constrained disease universe with a structured knowledge base and schema. This may be appropriate for some triage settings, but the paper should be clearer about the deployment scenario being modeled. The strongest interpretation is not that MOBAYES is generally better than LLM doctors, but that a structured Bayesian system can be superior in closed-world diagnostic dialogue tasks.
The knowledge base construction also needs more scrutiny. The empirical KB from DDxPlus may be well matched to the evaluation distribution, and the LLM-elicited KB may inherit the same biases or gaps as the model used to generate it. The paper would be stronger with more direct analysis of KB quality, calibration, coverage, and error propagation. Since the Bayesian module is only as good as its priors and likelihoods, KB reliability is central to the method.
Questions
How does MOBAYES behave when the true diagnosis is not present in the knowledge base? It would be useful to see an explicit open-set or missing-disease experiment, rather than relying only on threshold-based abstention.
How does the system handle comorbid disease, overlapping conditions, or patients with multiple simultaneous explanations for their symptoms? The current formulation appears to assume a single disease label.
Can the authors provide more detail on knowledge base calibration? In particular, how sensitive are results to errors in priors and conditional likelihoods, and how much performance drops when the KB is noisy or partially incomplete?
How fair is the comparison against standalone LLM doctors, given that MOBAYES uses a closed disease set and a structured feature schema? Can the authors report a comparison where standalone models are given the same disease universe and allowed to ask from the same feature schema?
How often does the parser make clinically meaningful errors, and what happens when parsing errors accumulate over multiple turns? It would help to separate errors due to parsing from errors due to the Bayesian reasoning module.
Can the authors evaluate on real clinical dialogue data, or at least provide a stronger discussion of what would likely change outside simulator-based evaluation?
Limitations
I think the limitations should be expanded in a few ways. First, the closed-world setting is not just a technical limitation but a major clinical boundary. The system may perform well when the correct answer is in the candidate set, but real clinical diagnosis often involves unexpected diseases, comorbidities, rare presentations, and uncertainty about what should even be in the candidate list.
Second, the simulated-patient evaluation should be presented more cautiously. Strong results on DDxPlus and simulator-based benchmarks are useful, but they are not evidence that the system is ready for clinical decision support. The paper should more clearly state that real-world prospective evaluation would be required before making claims about clinical usefulness.
Third, knowledge base quality should be treated as a core limitation. If priors or likelihoods are wrong, biased, outdated, or not representative of the target population, then the Bayesian module may produce confident but incorrect posteriors. The paper argues that KBs can be swapped for population-specific deployment, but this requires reliable local estimation, validation, and maintenance.
Fourth, the paper should discuss parser failure more directly. The LLM is not doing the diagnostic reasoning, but it still controls what evidence enters the Bayesian module. Misclassification of symptoms, uncertainty labels, negation, temporal information, or severity could have large downstream effects.
Final justification
I thank the authors for a thorough rebuttal with three well-targeted new experiments. The missing-diagnosis test directly addresses my open-set concern (88% vs 46% abstention at threshold 0.9, with a full sweep rather than a cherry-picked point), the KB noise-injection experiment usefully separates robustness to likelihood noise from sensitivity to coverage gaps, and the parser audit (92.5% accuracy, few polarity flips) is reassuring. The fairness ablation is the right control but I'd like the actual closed-world gap numbers surfaced in the main text rather than left to the appendix. My core reservation stands: all evidence, old and new, remains simulator-based, and the authors appropriately acknowledge prospective validation as a prerequisite rather than overclaiming. I'm keeping my score to reflect some distance from solid acceptance given this unresolved gap.
Formatting concerns
N/A
2 comments
Rebuttal
Response to Reviewer qoK6
We thank the reviewer for a careful and constructive review, and adopt the suggestions on the limitations section in full. We group the response into five topics and report three new experiments.
Topic 1: Simulated evaluation (W1, Q6)
Prospective validation is required and planned. We will state plainly in the limitations that DDxPlus is synthetic, our patients are simulated, and prospective evaluation with real patients and clinicians is required before any claim of clinical usefulness; this is an active direction of our work. To our knowledge no public dataset supports the controlled evaluation interactive diagnosis requires, i.e. arbitrary follow-up questions labelled with grounded answers. Structured questioning is also not merely a convenience: consultations should follow structured pathways ensuring guideline coverage under standardized case definitions (e.g. WHO IMCI). Our objective is not unconstrained conversation, but efficient acquisition of the information needed for accurate decision-making.
Robustness across independent simulators. We evaluate on three independent simulators (PatientSim on DDxPlus, MEDDxAgent's history-taking simulator, AgentClinic's patient agent), each with its own dialogue protocol and answer schema. Prior systems vary substantially across these three columns while MoBayes varies far less, which speaks to behaviour outside an expected schema.
Robustness across communication styles. Following PatientSim, whose authors note that simulators often fail to reflect the personas seen in practice (Kyung et al., 2025), we also stress-test patient behaviour. The persona study (Appendix C.8) covers five profiles including adversarial styles, mapping onto the exact failure modes raised: patients who volunteer extra information, misunderstand or recall poorly, and give guarded or inconsistent histories. Standalone GPT-5.4 collapses under these personas while MoBayes stays nearly stable, because the Bayesian engine accumulates evidence independently of surface style. We would like to promote this analysis to the main body.
Topic 2: Closed world, missing disease, comorbidity (W2, Q1, Q2)
The closed world is a deliberate, clinically motivated choice. We agree it is a clinical and not merely technical boundary and will present it as such. It integrates with guideline-driven consultation logic, where a fixed question set screens for a fixed outcome set; WHO IMCI, deployed in over 100 countries, likewise questions over a predefined decision space. MoBayes is a decision support system, not an autonomous diagnostician: when a presentation cannot be accounted for by the knowledge base, the correct behaviour is to defer to a clinician rather than force a diagnosis. This is why we report DHS, which makes the accuracy/coverage trade-off explicit.
(Experiment performed) Behaviour when the true diagnosis is absent. For DDxPlus PatientSim cases we removed the true diagnosis from the candidate space and reran the full dialogue, so abstention is the only correct outcome. Both arms receive the identical reduced list, and the standalone an explicit instruction to abstain if nothing matches. At threshold 0.9:
| Outcome | MoBayes | Standalone |
|---|---|---|
| Abstained | 44 (88%) | 23 (46%) |
| Committed (i.e. wrong) | 6 (12%) | 27 (54%) |
Because MoBayes compares the posterior against a threshold, the trade-off is controllable, whereas the standalone exposes no comparable knob. Sweeping it on the same cases:
| Threshold | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 0.95 |
|---|---|---|---|---|---|---|
| MoBayes committed | 36% | 28% | 26% | 22% | 12% | 12% |
| Standalone committed | 54% | 54% | 54% | 54% | 54% | 54% |
This does not rest on a favourably chosen operating point; it will be added to the appendix.
On open-set diagnosis (Q1). We do not claim a closed-world system can identify an omitted diagnosis; we test whether it recognises that its validated knowledge is insufficient. We deliberately do not generate candidates outside the knowledge base, since inventing them at inference time reintroduces the unvetted probability estimation the architecture excludes. In a hybrid deployment, exhausting the knowledge base could trigger a clearly signalled escalation to open-ended reasoning or clinician review: explicit and auditable, rather than unconstrained hypotheses silently entering the decision process. Modularity buys practitioner agency instead: new knowledge can be added to an explicit KB and validated by a human, which remains an open problem for an LLM-based probability surrogate.
On comorbidity (Q2). An excellent point, and a natural strength of the architecture: the engine does not commit to a single label internally but maintains a posterior over the full differential, which our Top-3 metric partially reflects and which is the natural substrate for multi-label inference. Available benchmarks provide one ground-truth label per case and no comorbid presentations, so we cannot evaluate this here; we will state it as a limitation and future work.
Topic 3: Fairness of the standalone comparison (W3, Q4)
We agree the deployment scenario should be stated explicitly: MoBayes targets closed-world decision support, where the candidate universe is set by the intended workflow, keeping the model inside its validated scope. We do not think the claim needs narrowing, because we already control for the structural advantage identified. Our Closed-World ablation gives the standalone doctor the same disease universe by placing the KB disease list directly in its prompt (Appendix B.2), under the same simulator and case set, and the gap does not close, indicating the gains do not arise from privileged access to the disease space. The missing-disease experiment above is a second control in the same spirit.
Topic 4: Knowledge base scrutiny (W4, Q3)
The knowledge base is explicit, learned and auditable, and we regard this data-dependency as a principal strength. Rather than encoding population statistics in model weights, it is learned in a deliberately unopinionated way from the training split: co-occurrence counts from the published DDxPlus records converted into Dirichlet-Categorical likelihoods (Appendix B.4), with no tuning toward the evaluation. If the statistics are wrong for a site, the remedy is better local data: an auditable fix, and a route to privacy-preserving contextualization without embedding patient records into model weights. Alignment with the evaluation distribution is thus the design goal of a site-specific backend, not a flaw. Our conclusions also do not depend on it: the same advantage holds with KBs elicited from frontier LLMs, independent of the DDxPlus training distribution, and on AgentClinic-MedQA.
(Experiment performed) Robustness across independently elicited KBs. Two KBs elicited from two independent frontier models agree closely on shared items (Pearson r = 0.931, MAE = 0.071, Appendix B.4) and both yield strong DHS, indicating broadly consistent medical knowledge rather than one model's idiosyncrasy. We also report KB informativeness and oracle ceilings (Appendix B.4).
(Experiment performed) Calibration and error propagation (Q3). We hold the dialogues of a clean run fixed (PatientSim) and replay the logged evidence through corrupted copies of the empirical KB, applying two corruptions at the likelihood layer: multiplicative log-normal noise on the conditional likelihoods with scale sigma, and random blanking of a fraction rho of (feature, disease) entries. We corrupt the empirical KB rather than the elicited one because it is the cleanest reference, so the injected noise is the only likelihood error. Mean DHS over 20 seeds:
| Sigma | 0 | 0.1 | 0.25 | 0.5 | 1.0 | 2.0 |
|---|---|---|---|---|---|---|
| DHS | 75.6 | 75.8 | 75.9 | 74.9 | 70.1 | 50.3 |
| Rho | 0 | 0.1 | 0.25 | 0.5 |
|---|---|---|---|---|
| DHS | 75.6 | 71.6 | 61.4 | 16.8 |
This separates two failure modes the question combines. Performance is flat under substantial mis-estimation of individual likelihoods (to sigma 0.5), degrading gracefully thereafter, but is far more sensitive to missing coverage: 10% blanking costs about 4 DHS, and beyond 25% the system loses its footing. The gains thus survive noisy likelihoods but depend on the KB covering the feature space, and coverage is an explicit, checkable property of an inspectable KB. We do not perturb the elicited KB further, as it is already a noisy realisation of the same quantities; the paper bounds its sensitivity: it is measurably less informative (Appendix B.4), yet an inexpensive same-family sensor still matches the frontier standalone (Appendix C.1).
Topic 5: Parser errors and their accumulation (Q5)
To quantify parser reliability and its downstream effect, we hand-labelled 200 sampled messages, and validated them with a blinded LLM judge. The parser extracts the correct value in 92.5% of cases, and its errors are dominated by the confidence label rather than the value, with over half of the joint (value, confidence) errors, an error in either field, being confidence-only, remaining value errors being mostly cautious miscalls on hedged replies (answering unknown where a value was supported, or committing to a value the reply was too vague to support), and outright polarity flips (a yes read as a no or the reverse) in only 1% of messages. The blinded judge reproduces the human labels closely, agreeing 96.5% of the time on values and 91.5% on confidence, and if anything over-counts errors, so the audit does not flatter us.
Limitations
We adopt all four suggestions: the revised section states the closed world as a clinical boundary including comorbidity, presents the simulated evaluation more cautiously with prospective validation stated as a prerequisite, treats KB quality and coverage as a core limitation given the noise results, and discusses parser failure directly.
Dear Reviewer qoK6,
Thank you again for the careful and constructive review. We wanted to check whether our response addressed the concerns you raised, in particular the new missing-disease experiment, the KB calibration and error-propagation study, and the parser audit. If any point remains open, or if there is further analysis that would be useful, we would be glad to provide it while the discussion period is still active. Should you feel your concerns have been resolved, we would be grateful if you would consider whether this warrants revisiting your assessment.
On originality
We would also like to briefly address the originality score. Our contribution is not Bayesian experimental design as such, but the strict separation between the LLM and the reasoning engine. Prior work in this space places the LLM inside the probabilistic engine, where it supplies patient-state distributions and likelihoods on the fly, whereas in MoBayes the LLM only verbalizes questions and parses replies, with priors and likelihoods coming from an explicit, auditable knowledge base. This distinction is what makes the system's estimates grounded rather than hallucination-prone, and it is why an inexpensive sensor model suffices to match frontier standalone doctors (Table 2; Appendix C.1). We position this against the hybrid family explicitly in our taxonomy (Section 2, Figure 1a) and survey the surrounding literature in detail in Appendix D.
Our taxonomy provides an in-depth analysis of this field of research. We believe that MoBayes opens up a fundamentally new approach. It isn’t simply a different agentic harness or prompting scheme; it is a different reasoning paradigm. By establishing a strict separation of language and reasoning, MoBayes has the following measurable advantages: (A) leading accuracy at massively reduced cost (using smaller models and fewer tokens), (B) calibrated abstention and differential diagnoses, (C) robustness across benchmark scenarios, prompting schemes, and most notably, adversarial patients.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Dear Area Chair CcVR,
We thank the AC for the metareview, and all three reviewers for the constructive discussion which we believe addresses the metareview's key concerns.
The metareview’s two concerns
1. The novelty concern.
We believe that MoBayes establishes an important new approach to a rapidly evolving field.
2. Naive Bayes is swappable, and the feared overconfidence is directly stress-tested. MoBayes abstains under uncertainty, where the standalone incorrectly commits.
Strengths recognized in the reviews
Additional insights provided during the peer review:
Where the discussion stands
We thank all three reviewers for the helpful discussion, and to the AC for their time.
Best,