ASSET: Acquisition-Sensitive Subspace Estimation for Test-Time Adaptation of Medical VLMs
Mohan Zhang, Zhen Tan, Songyuan Sui, Tianlong Chen
Abstract. Medical vision-language models are often adapted under high-quality acquisition conditions. At target deployment, the same model may face lower-quality scanners, protocols, reconstructions, or artifacts. These shifts change the visual evidence, while the intended clinical question remains unchanged. As a result, a source-adapted model can fail under this acquisition shift. Methods are proposed to solve this problem. Medical acquisition-shift correction mainly targets image-only predictors, leaving the multimodal model underexplored. Robust training depends on anticipated degradations, and generic test-time tuning can easily overfit the small target training set, leaving unknown acquisition shifts insufficiently corrected. In this paper, we hypothesize that acquisition-like augmentations of target examples can expose parameter directions responsible for acquisition-shift failures. Based on it, we propose ASSET, an Acquisition-Sensitive Subspace Estimation method for test-time adaptation. ASSET estimates an acquisition-sensitive parameter subspace from prediction and gradient changes under these augmentations. It then adapts the model within this subspace through iterative estimate-and-update rounds. Comprehensive experiments show the advantages of ASSET. For example, ASSET consistently improves target accuracy under acquisition-quality shift across datasets and backbones by 2.62% on average, while preserving performance when no shift is present. Under the strongest acquisition-quality shift, ASSET even improves target accuracy by 4.12%, showing that the correction generalizes to severe shifts.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:45 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
Reviewers saw both strengths and weaknesses in the submitted version of the paper. At the same time, the reviewers raised some questions, see Questions section. The concerns are primarily about the validation on real acquisition shifts, the clarification of the adaptation protocol and deployment assumptions, and better analysis of robustness and component contributions. These issues would require further clarification.
Final justification
The paper proposes ASSET, an acquisition-sensitive subspace adaptation method for medical VLMs under acquisition shifts. The reviewers generally find the problem important, the method technically sound, and the evaluation broad. The main concerns focused on the reliance on controlled degradations, robustness under small support sets, the contribution of individual components, and practical adaptation assumptions.
The rebuttal substantially addresses these concerns. Most importantly, the authors add acquisition-protocol experiments on MIMIC-CXR-VQA (PA→AP), where ASSET improves target performance while preserving source performance, providing useful evidence beyond simulated degradations. They also provide multi-split analyses with confidence intervals, smaller-support and reference-free experiments, and detailed component ablations showing that the learned acquisition-sensitive subspace and iterative refinement contribute meaningfully to the gains. The additional computational profiling further clarifies the deployment overhead.
Some limitations remain. In particular, most experiments still use controlled acquisition-like degradations, and the single PA/AP experiment does not fully establish generalization across heterogeneous scanners, sites, protocols, and reconstruction settings. The method also relies on a small labeled target support set, whose representativeness may affect adaptation. These limitations were also noted after rebuttal by one reviewer. However, I view them as limitations of the current scope rather than fundamental weaknesses of the proposed method.
Overall, the rebuttal addresses most of the reviewers' major concerns with substantial additional evidence, and the reviewers ultimately lean positive. Given the sound methodology, broad evaluation, and strengthened evidence after rebuttal, I recommend acceptance.
Read meta-review
Meta-review
Reviewers saw both strengths and weaknesses in the submitted version of the paper. At the same time, the reviewers raised some questions, see Questions section. The concerns are primarily about the validation on real acquisition shifts, the clarification of the adaptation protocol and deployment assumptions, and better analysis of robustness and component contributions. These issues would require further clarification.
Final justification
The paper proposes ASSET, an acquisition-sensitive subspace adaptation method for medical VLMs under acquisition shifts. The reviewers generally find the problem important, the method technically sound, and the evaluation broad. The main concerns focused on the reliance on controlled degradations, robustness under small support sets, the contribution of individual components, and practical adaptation assumptions.
The rebuttal substantially addresses these concerns. Most importantly, the authors add acquisition-protocol experiments on MIMIC-CXR-VQA (PA→AP), where ASSET improves target performance while preserving source performance, providing useful evidence beyond simulated degradations. They also provide multi-split analyses with confidence intervals, smaller-support and reference-free experiments, and detailed component ablations showing that the learned acquisition-sensitive subspace and iterative refinement contribute meaningfully to the gains. The additional computational profiling further clarifies the deployment overhead.
Some limitations remain. In particular, most experiments still use controlled acquisition-like degradations, and the single PA/AP experiment does not fully establish generalization across heterogeneous scanners, sites, protocols, and reconstruction settings. The method also relies on a small labeled target support set, whose representativeness may affect adaptation. These limitations were also noted after rebuttal by one reviewer. However, I view them as limitations of the current scope rather than fundamental weaknesses of the proposed method.
Overall, the rebuttal addresses most of the reviewers' major concerns with substantial additional evidence, and the reviewers ultimately lean positive. Given the sound methodology, broad evaluation, and strengthened evidence after rebuttal, I recommend acceptance.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper addresses test-time adaptation in medical VLMs. The authors assume that medical VLMs are often adapted on high-quality images but later deployed on lower-quality ones from different scanners, protocols, or reconstructions. This changes how images look without changing the clinical question, and it can cause the adapted model to fail. They propose ASSET, which applies acquisition-like proxy transformations to target examples and measures how sensitive the model's predictions are to them. From this sensitivity, it estimates a small parameter subspace responsible for acquisition-shift failures, and restricts adaptation to update only within that subspace. The proposed method has been evaluated across three medical VQA benchmarks (SLAKE, RadImageNet-VQA, GMAI-MMBench) and two backbones (InternVL3.5-8B, MedGemma-4B-IT).
Strengths and weaknesses
Strengths
Rather than just saying that acquisition-quality shift matters, the authors first demonstrate it. They show empirically that such shifts systematically degrade accuracy, and that naively fine-tuning on a small labeled target support set entangles genuine correction with harmful drift. The problem is realistic and well-scoped. The evaluation is broad and the central claim is properly validated. The paper is well-structured and well organised.
Weaknesses
The performance gains are modest and, more importantly, non-uniform in a way the aggregate numbers obscure. The abstract's +2.62 on average / +4.12 on the strongest shift is quite small. Table 1 shows that the advantage is concentrated on RadImageNet while largely vanishing on others. And the paper does not analyze why different datasets behaves differently. Another concern is that the medical evaluation rests entirely on physics-inspired synthetic degradations rather than real paired reference-quality and degraded acquisitions. A more fundamental concern is the paper's core directional assumption. The problem is formalized as correcting a model adapted on a high-quality source condition when deployed on a strictly lower-quality target condition, and synthetic shift family is a degradation layered on clean images. This high-to-low ordering is asserted rather than justified, yet real medical deployment may violates it: models are trained on large, heterogeneous, mixed-quality multi-site data and then deployed at a single higher-quality site, or the source and target differ in kind rather than along a clean quality axis.
Questions
-
Why does the proposed method underperform on SLAKE and GMAI, and what does this imply about when the method helps? In Table 1, ASSET trails MEMO on GMAI average (50.9 vs 51.4) and Tent on GMAI strongest-shift (40.0 vs 40.3). Similarly, the preformance on SLAKE is around 0.2-0.4%. A convincing analysis could help readers to understand if the benefit is intrinsically dataset-dependent.
-
How does ASSET behave on real paired clinical acquisitions rather than synthetic degradations? The medical results rely on CT/MRI/VAE synthetic degradations, which the conclusion flags as a limitation. Even a small pilot on a single real paired dataset (e.g., low-dose vs standard-dose CT, or differing reconstruction pipelines) would directly test whether the synthetic-to-real gap preserves the reported gains.
-
Can the contribution of the per-round iteration be isolated from the subspace constraint itself? Figure 5a shows accuracy improving over rounds, but it is not clear how much of ASSET's advantage comes from the iterative re-estimation versus a single subspace-constrained update. An ablation comparing one-round ASSET to the full iterative version (and to an unconstrained update run for the same number of steps) would help attribute the gains correctly and clarify the cost/benefit of the loop, which currently adds the most computational overhead.
-
Does ASSET generalize beyond the high-quality-source to low-quality-target direction? As noted in the weaknesses, the formulation and all synthetic shifts assume a high-quality source and a lower-quality target, and the ASSET appears specialized to this assumed direction. Could the authors discuss the generalisability?
Limitations
Partially. The authors do address limitations, but the discussion is thin relative to the scope of the work.
Final justification
Thanks the authors for the detailed rebuttal. The rebuttal has addressed most of my concerns, so I maintain the score.
Formatting concerns
No formating concerns.
2 comments
Dear Reviewer wh8U,
Thank you for your review. We posted our response a few days ago, reporting the evidence for all four questions you asked: a dataset-level explanation with five-split results on SLAKE and GMAI-MMBench, a real MIMIC-CXR PA→AP protocol evaluation, matched one-round, fixed-subspace, full, and unconstrained comparisons with runtime, and a clarification of generalization beyond high-to-low shifts.
While the discussion phase is open, we would be glad to know whether the response answers your questions.
Sincerely, The Authors
- Rating
- 4/6
- Confidence
- 2/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper studies test-time adaptation for medical vision-language models under directional acquisition-quality shift. The setting assumes a medical VLM that has been adapted under high-quality source acquisition conditions, but is later deployed under lower-quality target conditions caused by scanner, protocol, reconstruction, dose, or artifact differences. The clinical query is assumed to remain unchanged, while the visual evidence changes due to acquisition quality.
The proposed method, ASSET, estimates acquisition-sensitive parameter subspaces from a small labeled target support set. It creates acquisition-like proxy views of target examples, measures prediction discrepancies between original and proxy views, and differentiates these discrepancies to identify parameter directions that are sensitive to acquisition-quality variation. Adaptation is then constrained to this estimated subspace, using target supervision, proxy-view consistency, optional source/reference preservation terms, and iterative support-example weighting. The method is evaluated on SLAKE, RadImageNet-VQA, and GMAI-MMBench with InternVL3.5-8B and MedGemma-4B-IT under several controlled acquisition-quality degradations, with additional experiments on a general VQA robustness benchmark.
Strengths and weaknesses
Strengths
-
The paper studies acquisition-quality shift in medical VLM deployment, where scanner, protocol, reconstruction, dose, or artifact differences change image appearance while the clinical query remains unchanged. This is a relevant and underexplored problem for medical vision-language models.
-
The paper usefully distinguishes target correction from no-shift preservation. Instead of only improving performance on degraded target data, the method explicitly tries to avoid drifting away from the source-adapted model’s behavior under the original acquisition condition.
-
ASSET does not directly fine-tune all adaptable parameters on a small support set. Instead, it estimates acquisition-sensitive parameter directions from proxy-view prediction discrepancies and sensitivity gradients, and then constrains adaptation to the resulting subspace. This is a reasonable and nontrivial design choice.
-
The experiments compare ASSET with several types of baselines, including image correction, prediction aggregation, distribution alignment, cache adaptation, and test-time parameter-update methods. This makes the empirical comparison more informative than comparing only with standard fine-tuning or entropy minimization.
-
The reported results show that ASSET improves average shifted accuracy and strongest-shift accuracy over the source-adapted LoRA model, while largely preserving clean/no-shift performance.
Weaknesses
-
The motivation emphasizes real scanner, protocol, reconstruction, dose, and site differences, but the main experiments instantiate acquisition-quality shift through CT-Gaussian, CT-Poisson, MRI-Rician, MRI-k-space, and VAE-based degradations. These are useful stress tests, but they do not fully establish effectiveness under real clinical acquisition mismatch.
-
Since ASSET depends on proxy transformations to reveal acquisition-sensitive directions, it is important to know whether the proxy bank remains useful when the true target shift is not well approximated by the chosen transformations. The paper does not sufficiently analyze failure cases where proxy views are mismatched to the actual deployment shift.
-
The main experiments use both a labeled target support set and a no-shift reference set. The paper states that reference terms can be omitted, but the main results do not sufficiently clarify how much performance depends on this reference set.
-
The default setting uses 32 target support examples and 32 reference examples. The paper would be stronger if it reported results under smaller support sizes, such as 4, 8, and 16 examples, and under noisy support labels.
-
The improvements appear much larger on RadImageNet-VQA than on GMAI-MMBench. This raises the question of whether ASSET is generally effective across medical VQA tasks or mainly beneficial for particular datasets and shift families.
-
ASSET repeatedly computes proxy-view sensitivity gradients, eigendirections, and coefficient updates. The paper does not clearly report wall-clock time, GPU memory usage, or the number of forward/backward passes required per adaptation episode.
-
Adapting a medical VLM from a very small support set may introduce instability or site-specific bias. The paper should discuss how such adaptation would be validated, monitored, and constrained in clinical deployment.
Questions
- Can the authors provide any evaluation on real acquisition shift, such as scanner/protocol/site splits, low-dose vs standard-dose CT, accelerated vs standard MRI, or paired/near-paired clinical acquisition data? Even a modest real-world validation would substantially strengthen the paper. If such data are unavailable, please clarify how well the controlled degradations approximate realistic clinical acquisition shifts and where this approximation may fail.
- How sensitive is ASSET to the number of labeled target support examples and the availability of the no-shift reference set? Please report results with different support sizes, such as 4, 8, 16, and 32 examples, and include a setting without the reference set. This would clarify whether ASSET is practical under realistic low-label deployment conditions.
- Could the authors provide a fuller ablation across datasets and backbones? In particular, it would be useful to isolate the effects of the estimated subspace, proxy-view consistency, source/reference preservation, iterative re-estimation, and influence weighting. Comparisons with random low-rank subspaces, full LoRA adaptation with matched regularization, and a one-shot fixed ASSET subspace would help determine which components are essential.
- The gains on GMAI-MMBench appear much smaller than those on RadImageNet-VQA. What explains this dataset-level heterogeneity? Please provide per-backbone and per-shift-family results, preferably with standard deviations, confidence intervals, or paired significance tests. This would help determine whether the method is broadly reliable or mainly beneficial for specific dataset/shift combinations.
- What is the computational cost of ASSET relative to the baselines? Since the method repeatedly computes proxy-view sensitivity gradients, eigendirections, and coefficient updates, its wall-clock time and GPU memory overhead may be substantial for large VLMs. Please report the number of forward/backward passes, adaptation time, and memory usage per test-time adaptation episode.
Limitations
The authors acknowledge that the main medical target shifts are controlled degradations rather than real paired clinical acquisition data, which is an important limitation. However, the limitation discussion should be expanded. The paper should also discuss the sensitivity to the proxy transformation bank, possible failure modes when proxy transformations do not match the true acquisition process, the computational overhead of repeated gradient-based subspace estimation.
Final justification
The rebuttal provides useful additional evidence, including support-size analyses, broader ablations, and a real PA-to-AP protocol-shift experiment. These results strengthen the empirical evaluation but do not fully resolve my main concerns. ASSET still relies on a small labeled target support set to estimate its adaptation subspace, and its robustness to the composition and representativeness of this support set remains insufficiently characterized. Moreover, most evaluations are conducted using controlled simulated degradations. Although the proxy bank is reasonably designed and the PA/AP experiment is encouraging, a single real-protocol setting does not establish general applicability to heterogeneous scanner-, protocol-, reconstruction-, and site-level shifts in clinical CT and MRI.
Formatting concerns
No major formatting or anonymity concerns were observed.
2 comments
Rebuttal
We appreciate the reviewer recognizing the problem's importance, the soundness of our design, and the breadth of our experiments. We address each concern below.
[Cons 1. Real acquisition-shift validation?] We complement the controlled stress tests with a real acquisition-protocol evaluation using the recorded acquisition views in MIMIC-CXR-VQA. PA radiographs form the source and AP radiographs the target, reversing the projection geometry. We adapt InternVL3.5-8B on 32 AP support and 32 PA reference examples and evaluate 782 held-out AP and 146 PA questions over three draws. The unconstrained control uses identical data and losses.
| Evaluation | LoRA | ASSET w/o subspace | ASSET | Δ vs. LoRA | Δ vs. w/o subspace |
|---|---|---|---|---|---|
| AP target | 63.47 | 63.04 | 66.45 | +2.98 | +3.41 |
| PA source retention | 79.91 | 66.21 | 80.37 | +0.46 | +14.16 |
ASSET improves held-out AP (+2.98) and PA (+0.46), while unconstrained updating lowers both. This confirms real-protocol correction without source drift.
[Cons 2. Dependence on proxy–target matching?] We want to emphasize that ASSET's correction does not depend on exact proxy–target matching. What matters is whether proxy views reveal where acquisition changes affect the model. The real-protocol result confirms this: the bank does not model this protocol change, yet ASSET improves AP while maintaining PA. In the paper, CT-Gaussian/MRI-Rician tests exclude their matched proxies (Appendix C, Proxy banks), and Table 2 (Visual Robustness) holds out each target family, with gains in five of six cases. We further aggregate the proxy-bank ablation over all severities and families using MedGemma-4B-IT/RadImageNet-VQA:
| Proxy bank | Shift Avg. Δ vs. LoRA | Strongest Δ vs. LoRA |
|---|---|---|
| General image-quality transformations | +8.28 | +12.40 |
| Modality-informed transformations | +9.21 | +14.73 |
| General + modality-informed transformations | +8.52 | +12.07 |
The general bank shows that modality matching is unnecessary, while acquisition knowledge sharpens the signal. A bank is uninformative only if its views barely affect predictions or expose unrelated behavior.
[Cons 3. Dependence on the no-shift reference set?] We want to emphasize that target correction remains effective when the no-shift reference set is removed. On InternVL3.5-8B/GMAI-MMBench under the strongest CT-Gaussian shift, the reference-free variant retains 32 target labels but removes references and their losses.
| Method | Target labels | Reference examples | Strongest-shift accuracy | Δ vs. LoRA |
|---|---|---|---|---|
| LoRA | 0 | 0 | 25.33 | — |
| ASSET without reference | 32 | 0 | 26.67 | +1.33 |
| ASSET with reference | 32 | 32 | 28.00 | +2.67 |
The +1.33 reference-free gain shows that references help but are not required.
[Cons 4. Performance with fewer or noisy target labels?] Our default calibration budget is 32 labeled target examples, but ASSET already improves with only 4 target labels and remains effective under moderate label noise. On InternVL3.5-8B/GMAI-MMBench, we use nested support sets of 4–32 under the strongest CT-Gaussian shift, with the evaluation set and 32 references fixed.
| Target labels | LoRA | ASSET | Δ |
|---|---|---|---|
| 4 | 25.33 | 26.00 | +0.67 |
| 8 | 25.33 | 28.00 | +2.67 |
| 16 | 25.33 | 27.33 | +2.00 |
| 32 | 25.33 | 29.33 | +4.00 |
Noisy target labels. We replace 3 or 6 of 32 support labels with other valid choices and report strongest-shift accuracy over five draws with reference/evaluation fixed.
| Flipped support labels | LoRA | ASSET mean ± SD | Δ |
|---|---|---|---|
| 0 / 32 | 25.33 | 29.07 ± 2.24 | +3.73 |
| 3 / 32 (~10%) | 25.33 | 28.67 ± 2.16 | +3.33 |
| 6 / 32 (~20%) | 25.33 | 27.73 ± 2.29 | +2.40 |
Even with six corrupted labels, ASSET remains +2.40 above LoRA.
[Cons 5. Reliability across datasets, backbones, and acquisition shifts?] Our results show that ASSET delivers consistent gains across diverse medical VQA settings. The submitted main table already separates datasets. Below, we isolate backbone and family, then test split stability where gains are smaller.
Backbones. Aggregating all datasets and families, ASSET improves both VLMs:
| Backbone | LoRA Avg. | ASSET Avg. | Δ Avg. | LoRA Strongest | ASSET Strongest | Δ Strongest |
|---|---|---|---|---|---|---|
| InternVL3.5-8B | 69.42 | 71.50 | +2.08 | 57.70 | 60.96 | +3.26 |
| MedGemma-4B-IT | 64.89 | 68.05 | +3.16 | 51.94 | 56.92 | +4.97 |
Shift families. At fixed InternVL3.5-8B/RadImageNet-VQA, ASSET improves the average and strongest condition in all five families:
| Shift family | LoRA Avg. | ASSET Avg. | Δ Avg. | LoRA Strongest | ASSET Strongest | Δ Strongest |
|---|---|---|---|---|---|---|
| CT-Gaussian | 67.67 | 87.33 | +19.67 | 50.00 | 84.67 | +34.67 |
| CT-Poisson | 87.83 | 94.83 | +7.00 | 84.67 | 94.67 | +10.00 |
| MRI-Rician | 82.67 | 83.20 | +0.53 | 62.00 | 62.67 | +0.67 |
| MRI-k-space | 78.00 | 79.83 | +1.83 | 51.33 | 54.67 | +3.33 |
| VAE | 60.80 | 64.94 | +4.14 | 36.00 | 41.00 | +5.00 |
CT shifts preserve anatomy while creating larger acquisition-dependent errors, leaving more room for correction. MRI starts closer to ceiling under mild shifts, so less error is recoverable. The distinct learned-latent VAE shift also remains positive. Thus, magnitude follows available acquisition error, while every family improves.
Stability on SLAKE and GMAI-MMBench. With InternVL3.5-8B, we repeat all families over five matched support/reference splits and report paired ASSET−LoRA 95% CIs.
| Dataset | LoRA Avg. | ASSET Avg. | Paired Avg. Δ [95% CI] | LoRA Strongest | ASSET Strongest | Paired Strongest Δ [95% CI] |
|---|---|---|---|---|---|---|
| SLAKE | 78.87 | 79.91 | +1.04 [0.33, 1.76] | 71.74 | 73.70 | +1.96 [0.47, 3.45] |
| GMAI-MMBench | 56.61 | 57.26 | +0.66 [0.02, 1.29] | 43.60 | 44.59 | +0.99 [0.29, 1.68] |
All intervals remain positive, so the smaller gains persist across splits. RadImageNet-VQA has more recoverable acquisition error because its near-ceiling clean accuracy falls sharply under degradation. SLAKE has a smaller clean-to-shift drop, while GMAI-MMBench's broader tasks contain more non-acquisition error.
[Cons 6. Adaptation cost?] We view ASSET's overhead as a one-time calibration cost for each new acquisition condition. We profile three 40-step InternVL3.5-8B runs on one RTX 6000 Ada with 32 target/reference examples. The controls remove the constraint or estimate the subspace once.
| Method | Subspace estimates | Forward calls | Backward calls | Adaptation time | Peak GPU memory |
|---|---|---|---|---|---|
| ASSET w/o subspace | 0 | 408 | 400 | 84.81 ± 0.57 s | 19.61 GB |
| Fixed one-shot subspace | 1 | 504 | 504 | 159.22 ± 2.85 s | 21.02 GB |
| ASSET | 5 | 888 | 760 | 247.91 ± 2.99 s | 21.33 GB |
Repeated estimates add time but little memory. ASSET takes four minutes and uses standard inference afterward.
[Cons 7. Clinical deployment validation and monitoring?] We intend ASSET as a pre-deployment calibration procedure for a specific site and acquisition condition. An adapter should improve held-out local target cases without harming no-shift behavior, then be monitored on expert-labeled cases with source-model rollback available. Separate adapters keep calibration local to each site/condition, while ASSET's constraint and preservation objective limit drift. We will add this protocol to the discussion.
[Q3. Component contributions?] Our ablations reveal a clear contribution hierarchy: the learned acquisition-sensitive subspace provides the largest gain, while the training objectives, iterative refinement, and dynamic influence weighting provide additional improvements. We use fixed InternVL3.5-8B/RadImageNet-VQA support, reference, and evaluation sets and report each family's strongest shift.
Subspace mechanism. We compare refined directions with random, unconstrained, and fixed-initial-subspace controls.
| Method | CT-Gaussian | CT-Poisson | MRI-Rician | MRI-k-space | VAE | Average |
|---|---|---|---|---|---|---|
| ASSET | 84.67 | 94.67 | 68.67 | 58.00 | 42.33 | 69.67 |
| Random subspace updates | 49.33 | 84.00 | 62.00 | 52.00 | 36.00 | 56.67 |
| ASSET w/o subspace | 76.00 | 94.00 | 67.33 | 59.33 | 41.33 | 67.60 |
| Fixed one-shot subspace | 76.67 | 92.67 | 70.00 | 56.00 | 37.33 | 66.53 |
Its highest average supports the learned constraint and iterative refinement.
Training objectives. We retain the subspace and separately remove proxy-view consistency, no-shift reference anchoring, and source-prediction preservation.
| Variant | CT-Gaussian | CT-Poisson | MRI-Rician | MRI-k-space | VAE | Average |
|---|---|---|---|---|---|---|
| Full ASSET | 84.67 | 94.67 | 68.67 | 58.00 | 42.33 | 69.67 |
| Without consistency | 76.00 | 90.00 | 65.33 | 56.67 | 40.00 | 65.60 |
| Without reference supervision | 81.33 | 87.33 | 58.67 | 60.00 | 37.67 | 65.00 |
| Without preservation | 79.33 | 93.33 | 68.00 | 56.67 | 41.00 | 67.67 |
Influence weighting. We compare dynamic weighting of confident, proxy-sensitive examples with uniform weighting.
| Weighting | CT-Gaussian | CT-Poisson | MRI-Rician | MRI-k-space | VAE | Average |
|---|---|---|---|---|---|---|
| Dynamic influence weighting | 84.67 | 94.67 | 68.67 | 58.00 | 42.33 | 69.67 |
| Uniform weighting | 78.00 | 88.67 | 69.33 | 56.67 | 40.33 | 66.60 |
[Questions and limitations] Q1, Q2, Q4, and Q5 are addressed in Cons 1–2, 3–4, 5, and 6, respectively. Q3 is answered above. Cons 1/2/6/7 address the corresponding limitations.
Dear Reviewer eASb,
Thank you for your review. We posted our response a few days ago, reporting the additional experiments and analyses you asked for: a real MIMIC-CXR PA→AP protocol shift outside the proxy bank, reference-free, smaller-support, and noisy-label evaluations, paired results on SLAKE and GMAI-MMBench, the requested component ablations and adaptation-cost measurements, and a clinical validation and monitoring protocol.
While the discussion phase is open, we would be glad to know whether the response answers your questions, and welcome any further ones.
Sincerely, The Authors
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper studies test-time adaptation for medical VLMs under acquisition-quality shift. The setting is a medical VLM adapted under high-quality source acquisition conditions and later deployed under lower-quality or otherwise different target acquisition conditions, such as changes in scanner, protocol, reconstruction, dose, or artifact profile. The clinical query is assumed to remain unchanged while the image evidence changes.
The proposed method, ASSET, estimates an acquisition-sensitive parameter subspace from a small labeled target support set. It creates acquisition-like proxy views, measures prediction discrepancies between original and proxy-view inputs, and uses the resulting sensitivity gradients to extract low-dimensional adaptation directions. Adaptation is then restricted to this subspace and optimized with target supervision, proxy-view consistency, source/reference supervision when available, preservation loss, and coefficient regularization. The procedure is repeated over several rounds with support-example reweighting.
The evaluation uses SLAKE, RadImageNet-VQA, and GMAI-MMBench with InternVL3.5-8B and MedGemma-4B-IT. The target shifts are controlled CT-Gaussian, CT-Poisson, MRI-Rician, MRI-k-space, and VAE-based degradations. The authors report improved average shifted accuracy and strongest-shift accuracy over source-adapted LoRA and several adaptation, correction, cache, and distribution-alignment baselines. The paper also includes a mechanism diagnostic comparing ASSET-estimated subspaces with random subspaces, as well as a smaller experiment on a general VQA robustness benchmark.
Strengths and weaknesses
Strengths:
- The problem is well motivated. Medical VLMs are often evaluated under curated conditions, but deployment can involve scanner, protocol, reconstruction, dose, and artifact variation. This makes post-deployment adaptation for multimodal medical models a practically relevant problem.
- The method has a coherent mechanism and is well aligned with the motivation. The paper argues that direct target fitting can entangle acquisition-shift correction with support-specific fitting or reference drift. In response, ASSET applies acquisition-like perturbations to identify sensitivity gradients, estimates a low-dimensional update subspace from those gradients, and constrains adaptation to that subspace. This gives the method a clear rationale beyond a generic adapter-only or augmentation-only approach.
- The evaluation covers several relevant baseline categories, including image correction, prediction aggregation, distribution alignment, cache adaptation, and test-time parameter-update methods. This breadth is useful because the paper argues that generic adaptation signals may be insufficient for acquisition-quality shift.
- The mechanism diagnostic is useful. Comparing ASSET-estimated subspaces with random subspaces provides a reasonable sanity check that the selected directions capture target-correction structure, rather than arbitrary low-rank updates.
Weaknesses:
- The main medical evidence is still based on controlled degradations rather than real clinical acquisition shift. The paper is motivated by deployment under scanner, protocol, reconstruction, dose, and artifact variation, but the experiments approximate this setting with CT-Gaussian, CT-Poisson, MRI-Rician, MRI-k-space, and VAE-based degradations. These are useful stress tests, but they are not the same as real cross-scanner, cross-site, cross-protocol, reconstruction-kernel, or low-dose/standard-dose shifts. As a result, the evidence currently supports robustness to controlled acquisition-like corruptions more strongly than robustness to real clinical acquisition variation. The paper would be stronger with at least one real acquisition-shift experiment, such as cross-site MRI, scanner-vendor variation, reconstruction-kernel variation, or low-dose versus standard-dose CT. If such data are not available, the claims should be narrowed to controlled acquisition-like degradations.
- The aggregate results mask uneven gains across datasets. The overall shifted and strongest-shift improvements are encouraging, but the gains are not evenly distributed across datasets. In Table 1, the largest gains are on RadImageNet-VQA: average shifted accuracy improves from 71.8 to 78.9, and strongest-shift accuracy improves from 51.7 to 62.8. By contrast, the gains are much smaller on SLAKE, where average shifted accuracy improves from 79.0 to 79.6 and strongest-shift accuracy from 73.0 to 73.9, and on GMAI-MMBench, where average shifted accuracy improves from 50.8 to 50.9 and strongest-shift accuracy from 39.8 to 40.0. Because the method is presented as broadly applicable, this pattern makes the evidence less convincing. The authors should provide per-backbone, per-dataset, per-shift-family, and per-severity results, ideally with uncertainty estimates, and discuss why RadImageNet-VQA shows larger gains than the other benchmarks.
- The paper does not sufficiently quantify uncertainty under small support sets. ASSET uses a small labeled target support set, with a default size of 32 examples. In this setting, performance may depend on the particular support examples, reference examples, random seed, and proxy views used. The main table reports aggregate accuracies, but I do not see enough evidence from repeated support/reference splits, confidence intervals, or paired statistical tests. This matters because some gains are small, particularly on SLAKE and GMAI-MMBench. Repeating the experiments across multiple support/reference splits and reporting standard errors or confidence intervals would make the empirical conclusions more reliable. A paired analysis using the same support splits across methods would be especially useful.
- The adaptation setting and baseline protocol should be described more explicitly. ASSET assumes a small labeled target support set and, in the main reported setup, uses no-shift reference examples. This is a valid and potentially realistic clinical calibration scenario, but it differs from standard unlabeled test-time adaptation. These assumptions matter for practical deployment and for interpreting the baseline comparisons. Expert labels may be feasible for calibration, but they are not free. The paper would be stronger with results under weaker assumptions, such as smaller support sizes, adaptation without the no-shift reference set, or unlabeled/pseudo-labeled variants. A small protocol table would help readers check, for each baseline, whether it uses target labels, unlabeled target images, source/no-shift reference data, matched support sizes, and tuned hyperparameters. This would make it clearer whether the reported gains come from the proposed subspace mechanism or from differences in supervision or reference data across methods.
- The ablations could better isolate ASSET’s main components. The round-dynamics and proxy-bank ablations are useful, and the projection diagnostic provides a helpful random-direction control. However, ASSET still combines several ingredients. Additional performance ablations that test the subspace mechanism, such as random subspace updates, no subspace constraint, fixed one-shot subspace, no consistency or source/preservation losses, no influence weighting, and different rank choices, would clarify whether the acquisition-sensitive subspace is the main contributor.
- Reproducibility and deployment-cost details could be stronger. The manuscript reports many useful configuration details. Still, exact reproduction would be easier with released code, split files for the support and reference sets, detailed baseline scripts, multiple random seeds, and uncertainty estimates. Since ASSET uses gradient-based subspace estimation and iterative updates for large VLMs, runtime and memory overhead should also be reported more prominently.
Questions
- Can the authors provide per-backbone, per-dataset, per-shift-family, and per-severity results with confidence intervals over multiple support/reference splits? Stable improvements across these conditions would increase my confidence. If the gains are mainly concentrated in RadImageNet-VQA or are unstable under support-set resampling, the paper should state this limitation more explicitly.
- Can the authors clarify what information each baseline has access to during adaptation? A protocol table specifying, for each method, whether it uses target labels, unlabeled target images, source/no-shift reference data, matched support sizes, and tuned hyperparameters would help. This would make it easier to judge whether ASSET’s gains come from the proposed subspace mechanism or from differences in supervision, reference data, or tuning protocol across methods.
- How does ASSET perform without the no-shift reference set and with smaller target support sizes, such as 4, 8, and 16 examples? Strong performance under these reduced assumptions would make the method more practically compelling. If performance depends strongly on 32 labeled target examples plus reference data, the paper should state this deployment assumption more explicitly.
- Do the authors have any evidence on real scanner, site, or protocol acquisition shift, even if limited, such as cross-site data, scanner-vendor variation, reconstruction-kernel variation, or low-dose versus standard-dose CT? If not, I encourage narrowing the claims to controlled acquisition-like degradations. A real acquisition-shift result would substantially strengthen the deployment motivation, while careful claim calibration would also help address this concern.
- Can the authors provide additional performance ablations that better isolate the subspace mechanism, such as random subspace updates, no subspace constraint, fixed one-shot subspace estimation, removal of consistency or source/preservation losses, removal of influence weighting, and different rank choices? These would help clarify whether the acquisition-sensitive subspace, rather than the combination of auxiliary losses and iterative tuning, is the main driver of the reported gains.
Limitations
The authors acknowledge an important limitation: the medical target shifts are controlled degradations rather than real paired clinical acquisition data. However, because acquisition shift is central to the paper’s motivation, the limitations discussion should explain more clearly how this affects interpretation of the results.
In particular, the paper should more explicitly discuss its dependence on labeled target support examples, the use of no-shift reference data, possible variability from small support-set sampling, the concentration of gains in RadImageNet-VQA, the lack of real scanner/site/protocol validation, limited uncertainty reporting, and adaptation-time compute or memory cost. These points do not undermine the proposed method, but they mean that the current evidence supports robustness to controlled acquisition-like degradations more strongly than robustness to real clinical acquisition variation.
The paper should also state more clearly that ASSET has not been validated for clinical deployment. Before making stronger deployment-oriented claims, the method would need validation under real clinical acquisition variation, site heterogeneity, calibration analysis, and clinical workflow constraints relevant to VQA use.
Final justification
The rebuttal and additional experiments address most of my original concerns, especially regarding result stability, adaptation settings, and the contribution of the proposed components. The added MIMIC-CXR-VQA PA→AP experiment also provides useful evidence beyond controlled degradations, although broader real-world validation remains limited. I therefore increase my rating from 3 to 4.
Formatting concerns
No major formatting or anonymity concerns observed.
2 comments
Rebuttal
We appreciate the reviewer recognizing the problem's importance, the method's coherence, and the evaluation's breadth. We address each concern below.
[Cons 1. Real acquisition-shift validation?] We want to clarify that the controlled degradations are systematic stress tests, not the boundary of ASSET's applicability. To directly test real acquisition variation, we use the recorded acquisition views in MIMIC-CXR-VQA to construct a real protocol shift. PA radiographs form the source and AP radiographs the target, reversing the projection geometry. We adapt InternVL3.5-8B on 32 AP support and 32 PA reference examples and evaluate 782 held-out AP and 146 PA questions over three draws. The unconstrained control uses the same data and losses.
| Evaluation | LoRA | ASSET w/o subspace | ASSET | Δ vs. LoRA | Δ vs. w/o subspace |
|---|---|---|---|---|---|
| AP target | 63.47 | 63.04 | 66.45 | +2.98 | +3.41 |
| PA source retention | 79.91 | 66.21 | 80.37 | +0.46 | +14.16 |
ASSET improves held-out AP (+2.98) and PA (+0.46), while unconstrained updating lowers both. This confirms real-shift correction without source drift.
[Cons 2. Reliability across backbones, datasets, and acquisition shifts?] We emphasize that the different gain magnitudes across datasets reflect how much acquisition-dependent error each benchmark exposes, while ASSET's improvement is not confined to one backbone or acquisition-shift family. The complete grid has 132 shifted settings, so we separate the requested axes.
Datasets and backbones. The submitted main table already separates datasets. RadImageNet-VQA falls sharply from near-ceiling clean accuracy. SLAKE has less clean-to-shift error, while GMAI-MMBench's broader tasks contain more clean error. We aggregate all datasets and families by backbone:
| Backbone | LoRA Avg. | ASSET Avg. | Δ Avg. | LoRA Strongest | ASSET Strongest | Δ Strongest |
|---|---|---|---|---|---|---|
| InternVL3.5-8B | 69.42 | 71.50 | +2.08 | 57.70 | 60.96 | +3.26 |
| MedGemma-4B-IT | 64.89 | 68.05 | +3.16 | 51.94 | 56.92 | +4.97 |
Shift families and severities. At fixed InternVL3.5-8B/RadImageNet-VQA, each cell reports LoRA → ASSET (Δ) from mild to strong:
| Shift family | Severity 1 | Severity 2 | Severity 3 | Severity 4 | Severity 5 | Mean Δ | Strongest Δ |
|---|---|---|---|---|---|---|---|
| CT-Gaussian | 92.67→93.33 (+0.67) | 78.67→87.33 (+8.67) | 49.33→84.00 (+34.67) | 50.00→84.67 (+34.67) | — | +19.67 | +34.67 |
| CT-Poisson | 87.33→94.00 (+6.67) | 91.33→95.33 (+4.00) | 88.00→95.33 (+7.33) | 84.67→94.67 (+10.00) | — | +7.00 | +10.00 |
| MRI-Rician | 97.33→96.00 (−1.33) | 92.67→92.67 (+0.00) | 86.00→87.33 (+1.33) | 75.33→77.33 (+2.00) | 62.00→62.67 (+0.67) | +0.53 | +0.67 |
| MRI-k-space | 95.33→95.33 (+0.00) | 92.67→92.67 (+0.00) | 72.67→76.67 (+4.00) | 51.33→54.67 (+3.33) | — | +1.83 | +3.33 |
| VAE | 96.00→96.67 (+0.67) | 80.00→81.67 (+1.67) | 54.00→60.67 (+6.67) | 38.00→44.67 (+6.67) | 36.00→41.00 (+5.00) | +4.14 | +5.00 |
CT noise retains anatomy while creating recoverable image-statistic errors. MRI begins near ceiling, with gains emerging as noise or undersampling alters structural cues. VAE improves at every level despite its distinct latent shift. Gains are limited near ceiling and increase once degradation creates a meaningful visual shift.
[Cons 3. Sensitivity to support and reference splits?] We want to make clear that ASSET's gains on SLAKE and GMAI-MMBench remain stable as the support/reference examples change and also persist against another method given the same target support. We evaluate InternVL3.5-8B across five splits and families, pairing ASSET and Tip-Adapter on the same 32 labels.
| Dataset | Baseline | Baseline Shift Avg. | ASSET Shift Avg. | Paired Avg. Δ (ASSET−Baseline) [95% CI] | Baseline Strongest | ASSET Strongest | Paired Strongest Δ (ASSET−Baseline) [95% CI] |
|---|---|---|---|---|---|---|---|
| SLAKE | LoRA | 78.87 | 79.91 | +1.04 [0.33, 1.76] | 71.74 | 73.70 | +1.96 [0.47, 3.45] |
| Tip-Adapter | 60.73 | 79.91 | +19.18 [9.20, 29.16] | 56.99 | 73.70 | +16.71 [7.11, 26.31] | |
| GMAI-MMBench | LoRA | 56.61 | 57.26 | +0.66 [0.02, 1.29] | 43.60 | 44.59 | +0.99 [0.29, 1.68] |
| Tip-Adapter | 52.58 | 57.26 | +4.68 [3.85, 5.52] | 40.65 | 44.59 | +3.93 [3.21, 4.66] |
All paired intervals are positive. With the same labels, ASSET updates the shifted distribution rather than a local cache.
[Cons 4a. Performance with fewer target labels?] We want to emphasize that 32 labeled target examples are our default calibration budget, not a minimum requirement for ASSET to identify an acquisition-sensitive correction. On InternVL3.5-8B/GMAI-MMBench, we vary nested support from 4 to 32 with 32 references under the strongest CT-Gaussian shift.
| Target labels | LoRA | ASSET | Δ |
|---|---|---|---|
| 4 | 25.33 | 26.00 | +0.67 |
| 8 | 25.33 | 28.00 | +2.67 |
| 16 | 25.33 | 27.33 | +2.00 |
| 32 | 25.33 | 29.33 | +4.00 |
[Cons 4b. Adaptation without a no-shift reference set?] We want to make clear that ASSET does not require a no-shift reference set to correct the target shift. In the Cons 4a setting, we retain 32 target labels but remove references and their losses.
| Method | Target labels | Reference examples | Strongest-shift accuracy | Δ vs. LoRA |
|---|---|---|---|---|
| LoRA | 0 | 0 | 25.33 | — |
| ASSET without reference | 32 | 0 | 26.67 | +1.33 |
| ASSET with reference | 32 | 32 | 28.00 | +2.67 |
The +1.33 gain without references shows that they help but are not required.
[Cons 4c. Data available to each baseline?] We evaluate each baseline with the information required by its original design. All start from the same source-adapted LoRA, with 32 examples in every offline target/reference pool.
| Method | Target information during adaptation | No-shift/source reference |
|---|---|---|
| LoRA | None | None |
| HistMatch | Current test image | 32 unlabeled no-shift images |
| NLM, TTAug, ZERO, MEMO | Current test image | None |
| UPA, CORAL | 32 unlabeled target examples | 32 unlabeled no-shift examples |
| BCA, TDA, SAR | Online target stream | None |
| Tent | 32 unlabeled target examples | None |
| TTAdapt | 32 pseudo-labeled target examples | None |
| Tip-Adapter | 32 labeled target examples | None |
| ASSET | 32 labeled target examples | 32 labeled no-shift examples |
Each baseline uses one configuration. Cons 3 matches Tip-Adapter's labels, and Cons 5 fixes ASSET's data/objectives without its subspace. These controls isolate mechanism gains from information access.
[Cons 5. Sources of ASSET's gains?] We emphasize that the learned acquisition-sensitive subspace is the central mechanism behind ASSET's gains, while its training objectives, dynamic influence weighting, and subspace capacity each make complementary contributions. All controls use InternVL3.5-8B/RadImageNet-VQA at each family's strongest shift.
Subspace mechanism. We compare refined directions with random, unconstrained, and fixed-initial-subspace controls.
| Method | CT-Gaussian | CT-Poisson | MRI-Rician | MRI-k-space | VAE | Average |
|---|---|---|---|---|---|---|
| ASSET | 84.67 | 94.67 | 68.67 | 58.00 | 42.33 | 69.67 |
| Random subspace updates | 49.33 | 84.00 | 62.00 | 52.00 | 36.00 | 56.67 |
| ASSET w/o subspace constraint | 76.00 | 94.00 | 67.33 | 59.33 | 41.33 | 67.60 |
| Fixed one-shot subspace | 76.67 | 92.67 | 70.00 | 56.00 | 37.33 | 66.53 |
Its highest average supports the learned constraint and iterative refinement.
Training objectives. We retain the subspace and separately remove proxy-view consistency, no-shift reference anchoring, and source-prediction preservation.
| Variant | CT-Gaussian | CT-Poisson | MRI-Rician | MRI-k-space | VAE | Average |
|---|---|---|---|---|---|---|
| Full ASSET | 84.67 | 94.67 | 68.67 | 58.00 | 42.33 | 69.67 |
| Without consistency | 76.00 | 90.00 | 65.33 | 56.67 | 40.00 | 65.60 |
| Without reference supervision | 81.33 | 87.33 | 58.67 | 60.00 | 37.67 | 65.00 |
| Without preservation | 79.33 | 93.33 | 68.00 | 56.67 | 41.00 | 67.67 |
Influence weighting. We compare dynamic weighting of reliable, proxy-sensitive examples with uniform weighting.
| Weighting | CT-Gaussian | CT-Poisson | MRI-Rician | MRI-k-space | VAE | Average |
|---|---|---|---|---|---|---|
| Dynamic influence weighting | 84.67 | 94.67 | 68.67 | 58.00 | 42.33 | 69.67 |
| Uniform weighting | 78.00 | 88.67 | 69.33 | 56.67 | 40.33 | 66.60 |
Rank sensitivity. We vary the maximum retained directions with all else fixed.
| Maximum subspace rank | CT-Gaussian | CT-Poisson | MRI-Rician | MRI-k-space | VAE | Average |
|---|---|---|---|---|---|---|
| 2 | 76.00 | 90.00 | 64.67 | 58.67 | 36.00 | 65.07 |
| 4 | 82.00 | 90.67 | 68.00 | 62.67 | 35.00 | 67.67 |
| 8 | 77.33 | 91.33 | 68.00 | 58.00 | 37.67 | 66.47 |
| 16 (ASSET) | 84.67 | 94.67 | 68.67 | 58.00 | 42.33 | 69.67 |
[Cons 6. Reproducibility and adaptation cost?] We will release our code and the materials needed to reproduce our results upon acceptance. We profile three InternVL3.5-8B runs with 32 target/reference examples on one RTX 6000 Ada.
| GPU | Update steps | Adaptation time | Average time per step | Peak GPU memory |
|---|---|---|---|---|
| NVIDIA RTX 6000 Ada | 40 | 247.91 ± 2.99 s | 6.20 s | 21.33 GB |
One-time adaptation takes four minutes and adds no inference-time optimization.
[Questions and limitations] Q1–Q5 correspond to Cons 2–3, 4c/5, 4a–b, 1, and 5. Cons 1–4/6 address the limitations. Site-specific adapters require held-out target/no-shift validation, with source model retained for rollback.
Dear Reviewer 2KtG,
Thank you for your review. We posted our response a few days ago, reporting the additional evidence you asked for: a real MIMIC-CXR PA→AP protocol evaluation, per-backbone, per-family, and per-severity results, paired five-split analyses on SLAKE and GMAI-MMBench, smaller-support and reference-free settings, a baseline-access table, and the requested component ablations and adaptation-cost measurements.
While the discussion phase is open, we would be glad to know whether the response answers your questions, and welcome any further ones.
Sincerely,
The Authors
Comments on the paper
1 comment
[NeurIPS 2026] Discussion
Dear everyone,
Thank you very much for your contribution to this submission. The authors have now posted their responses.
Please note the following key deadlines and requirements from the NeurIPS 2026 PC Chairs.
- Aug 3: Final day for author-reviewer-AC discussion.
- Aug 10: Deadline for reviewer-AC discussion.
To Reviewers: Your participation is crucial. Please look at the response alongside the other reviews, and engage in the discussion to address any major points of disagreement or to clarify your final stance.
Thanks,
AC
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Rebuttal
We're glad that the reviewer found the problem realistic and well scoped, our evaluation broad, and the central claim properly validated. We respond to the reviewer's concerns and questions point by point below.
[Con 1 & Q1. Magnitude and dataset heterogeneity of the gains?] We do not think the overall improvement is appropriately characterized as small. The relevant comparison is whether one method improves already source-adapted medical VLMs over the strongest alternatives across the complete evaluation. ASSET is evaluated over 30 backbone–dataset–shift combinations, including mild conditions where the source model is already near ceiling and little acquisition-induced error remains to correct. It nevertheless achieves the best overall shifted accuracy, with the advantage becoming larger under the strongest shifts.
The overall result summarizes the complete grid, while the main-results table in the paper reports every dataset separately. The variation across datasets identifies when acquisition-sensitive adaptation has more error to correct. On RadImageNet-VQA, the source-adapted model is near ceiling on clean images (96.3), but falls to 71.8 on shifted images, so most of the new error is induced by acquisition degradation. SLAKE has a much smaller clean-to-shift drop (88.1 to 79.0). GMAI-MMBench begins at 72.7 even on clean images, so a substantial part of its error comes from heterogeneous anatomy and diagnosis questions that acquisition correction is not intended to repair. ASSET therefore helps most when acquisition variation accounts for a substantial share of the deployed model's error.
The question cites MEMO as 51.4 on GMAI-MMBench, but the main-results table reports 51.1 for MEMO. The 51.4 result belongs to ZERO. More importantly, no competing method dominates ASSET on both GMAI shifted metrics: ZERO obtains 51.4/39.8 for Avg./Strongest, Tent obtains 50.6/40.3, and ASSET obtains 50.9/40.0. On SLAKE, ASSET achieves the best Avg. and Strongest results, 79.6 and 73.9. We further repeat the complete five-family evaluation over five support/reference splits with InternVL3.5-8B:
The paired intervals remain above zero on both datasets. The smaller non-RadImageNet gains reflect a smaller acquisition-specific share of their total error, and they do not disappear as the calibration examples change.
[Con 2 & Q2. Real clinical acquisition-shift evidence?] We complement the controlled medical stress tests with a native clinical acquisition-protocol evaluation. We use the recorded acquisition views in MIMIC-CXR-VQA to construct this real protocol shift. Posteroanterior (PA) radiographs form the source condition and anteroposterior (AP) radiographs form the target condition. These views reverse the X-ray projection direction relative to the patient, changing acquisition geometry and image appearance. We adapt InternVL3.5-8B with 32 labeled AP support examples and 32 PA reference examples, then evaluate on 782 held-out AP and 146 held-out PA questions. Results are averaged over three calibration draws. ASSET w/o subspace uses the same calibration examples and losses but updates all trainable adapter parameters directly.
ASSET transfers the correction from 32 AP support examples to held-out AP questions while maintaining accuracy under the original PA protocol. The unconstrained control receives the same calibration information, yet does not improve AP and causes substantial PA drift. The evaluation uses native clinical acquisitions, and the proxy bank contains no view-position or projection-reversal operation. The result shows that ASSET can adapt to a real clinical acquisition change outside the five controlled degradation families.
[Q3. Contribution and cost of iterative re-estimation?] Our results show that iterative re-estimation contributes beyond both the subspace constraint and the number of optimization updates. We compare matched variants on MedGemma-4B-IT and SLAKE under CT-Gaussian shifts. All use the same 32 target and 32 reference examples, losses, and 40 updates. One-round ASSET performs all updates after a single estimate, fixed one-shot keeps its initial subspace across rounds, full ASSET re-estimates it each round, and ASSET w/o subspace removes the constraint.
Full ASSET exceeds both one-round and fixed one-shot ASSET, showing that its advantage is not explained by performing more updates or merely estimating one useful low-dimensional basis. The much larger gap over the unconstrained control separately establishes the value of restricting adaptation to acquisition-sensitive directions.
In our end-to-end profiling on one NVIDIA RTX 6000 Ada GPU, fixed one-shot requires 159.22 seconds and full ASSET requires 247.91 seconds. This additional computation is a one-time calibration cost for a new acquisition condition. After adaptation, ASSET uses the same VLM architecture without per-example optimization or additional inference modules.
[Q4. Generalization beyond high-quality source to lower-quality target?] We want to clarify that high-to-low deployment is the concrete and practically important acquisition-shift scenario studied in the paper, while ASSET's adaptation rule is defined by source and target distributions rather than their relative image quality. ASSET adapts a model from its source distribution to the deployment distribution represented by target support, while preserving behavior on the source. In our formulation, the source distribution is the condition used to train the source-specific LoRA adapter, even when the foundation model was pretrained on mixed-quality, multi-site data. The same formulation therefore applies when the target site has higher image quality.
Proxy views serve as sensitivity probes, so they do not require the target condition to follow the same degradation direction. Our MIMIC-CXR-VQA experiment provides a concrete example. PA and AP differ in projection geometry, the proxy bank contains no corresponding transformation, and ASSET still improves AP by 2.98 while retaining PA accuracy. ASSET is therefore directional in the usual adaptation sense of moving from a designated source distribution to a designated target distribution, rather than being specialized to decreasing image quality.