On-Policy Hindsight Distillation for Early Risk Prediction
Qiannan Zhang, Fei Wang
NeurIPS 2026
Abstract. Early prediction of chronic disease risk from electronic health records (EHRs) is challenging because early clinical signals are often sparse, noisy, and indirectly related to future outcomes. Existing methods typically learn from prediction-time records and final outcome labels alone, which provides limited supervision for identifying weak early signals from heterogeneous and confounded clinical records. LLM-generated rationales offer an intermediate form of prediction-time reasoning, but rationales derived from early EHR may still miss weak signals whose relevance becomes clearer only in later records. We therefore use follow-up EHR observed after the prediction time but before outcome assessment as training-time hindsight and propose On-Policy Hindsight Distillation (OPHD), a self-distillation framework that converts follow-up EHR into training signals for LLM-generated prediction-time rationales. Specifically, OPHD first uses an LLM to generate a rationale from prediction-time EHR alone, then re-evaluates the same rationale under privileged follow-up views to derive token-level signals that are distilled back to the prediction-time policy. To handle noisy follow-up records, OPHD emphasizes hindsight signals that are stable across perturbed privileged views. A task-grounded scorer further prioritizes rationales that improve downstream risk discrimination. Experiments on multiple real-world neurodegenerative disease cohorts show that OPHD achieves the best long-horizon prediction performance compared with a variety of baselines.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:44 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
There are certain shared weakness pointed out by reviewers:
-
Limited experimental scope (models and benchmarks). The evaluation relies on a single baseline model (Qwen3-4B-Instruct-2507), leaving the method's effectiveness across other model sizes and families unestablished. The paper also omits standard field benchmarks without justifying this choice, making it difficult to situate the results relative to prior work.
-
Low absolute performance and unclear clinical utility. Although the method delivers consistent relative gains over baselines, absolute predictive performance is weak — AUPRC values fall around 0.01–0.03 across cohorts, and PPV at 90% specificity remains very low. In a realistic screening setting, this implies many false positives per true positive, raising doubts about clinical actionability regardless of the relative improvements.
-
Narrow generalization evidence. The evaluation is confined to three neurodegenerative disease cohorts with similar temporal characteristics. This weakens claims of broad applicability, since there is no evidence of transfer to other clinical domains or independent data sources.
-
Underspecified methodology (frozen re-scoring model). The paper does not clarify whether the re-scoring model is fixed at initialization or periodically synchronized with the policy model. This ambiguity has real consequences: a never-updated re-scorer risks stale token-level preferences, while an updated one introduces nonstationary training targets. Either way, the design choice and its implications need to be made explicit.
We would strongly recommend the authors to clarify those weakness and provide answers to detailed questions raised by each reviewer during the rebuttal phase.
Final justification
The authors have successfully address the concerns raised by reviewers. Although some limitations remain, including low absolute PPV and limited strict shift and fairness evaluations, we decide to accept this work based on the comprehensive experiments and solid contributions.
Read meta-review
Meta-review
There are certain shared weakness pointed out by reviewers:
-
Limited experimental scope (models and benchmarks). The evaluation relies on a single baseline model (Qwen3-4B-Instruct-2507), leaving the method's effectiveness across other model sizes and families unestablished. The paper also omits standard field benchmarks without justifying this choice, making it difficult to situate the results relative to prior work.
-
Low absolute performance and unclear clinical utility. Although the method delivers consistent relative gains over baselines, absolute predictive performance is weak — AUPRC values fall around 0.01–0.03 across cohorts, and PPV at 90% specificity remains very low. In a realistic screening setting, this implies many false positives per true positive, raising doubts about clinical actionability regardless of the relative improvements.
-
Narrow generalization evidence. The evaluation is confined to three neurodegenerative disease cohorts with similar temporal characteristics. This weakens claims of broad applicability, since there is no evidence of transfer to other clinical domains or independent data sources.
-
Underspecified methodology (frozen re-scoring model). The paper does not clarify whether the re-scoring model is fixed at initialization or periodically synchronized with the policy model. This ambiguity has real consequences: a never-updated re-scorer risks stale token-level preferences, while an updated one introduces nonstationary training targets. Either way, the design choice and its implications need to be made explicit.
We would strongly recommend the authors to clarify those weakness and provide answers to detailed questions raised by each reviewer during the rebuttal phase.
Final justification
The authors have successfully address the concerns raised by reviewers. Although some limitations remain, including low absolute PPV and limited strict shift and fairness evaluations, we decide to accept this work based on the comprehensive experiments and solid contributions.
1 comment
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes OPHD, a self-distillation framework for early disease risk prediction from EHR data. The key idea is to use follow-up EHR, available only during training, as privileged hindsight information to improve LLM-generated rationales. The rationale is generated only from prediction-time EHR, and the same rationale is then re-scored under perturbed follow-up views to identify stable token-level hindsight signals. These signals are further weighted by a task-grounded scorer to prioritize rationales that improve downstream risk prediction. Experiments on AD, PD, and ADRD cohorts show consistent improvements over conventional EHR models and several LLM-based reasoning baselines.
Strengths and weaknesses
Strengths:
- The paper tackles an important real-world problem, namely long-horizon risk prediction from sparse and noisy EHR data. The motivation is strong, especially because the method aims to use follow-up records during training without violating the inference-time constraint that only prediction-time EHR is available.
- The core idea is well designed, as keeping rationales on-policy and using follow-up EHR only to re-score the same rationale under perturbed privileged views helps avoid the train-test mismatch of directly imitating follow-up-conditioned rationales.
- The ablations, direct-imitation comparison, follow-up-window analysis, and additional pancreatic-cancer experiment support these design choices and the broader applicability of the framework. Overall, the paper is clear and technically solid.
Weaknesses:
- The practical significance remains somewhat limited. Although the added calibration analysis better contextualizes the results, the absolute AUPRC and positive predictive value (PPV) at 90% specificity remain low, and clinical actionability is not yet established.
- The additional pancreatic-cancer experiment broadens the evaluation beyond neurodegenerative disease, and the OHSU cohort provides evidence from an independent data source. However, strict cross-site transfer and calendar-time temporal-shift validation remain limited.
- While the specific combination of on-policy rationale generation, hindsight re-scoring, and task-grounded feedback is interesting, the individual components build on established ideas in privileged information, self-distillation, and scorer-guided learning. Thus, the novelty lies mainly in their coordinated integration rather than in each component individually. Nevertheless, the consistent gains across cohorts, the careful ablations, the comparison against direct follow-up-conditioned imitation, and the additional analyses make the submission convincing overall.
Questions
- OPHD uses follow-up EHR during training. Are the gains mainly coming from records that are very close to the diagnosis or index time? What happens if those near-index records are removed?
- The reported positive predictive value (PPV) is low even at 90% specificity. Can the authors show calibration results or decision-curve analysis to clarify whether the model would be useful in practice?
- The evaluation is limited to neurodegenerative disease cohorts. Can the authors provide evidence that OPHD is robust under temporal shift, site shift, or evaluation on an independent external dataset?
- The method uses generated rationales, but the main results focus on prediction scores. Can the authors show examples or clinician-reviewed failure cases to demonstrate that OPHD improves rationale quality rather than only prediction performance?
Limitations
The limitations are better addressed. The authors acknowledge that generated rationales should be treated as intermediate model outputs rather than clinical explanations, and the rebuttal adds a broader disease-domain experiment and calibration analysis. However, the discussion should still more directly address the low absolute PPV, lack of strict cross-site transfer or calendar-time temporal-shift validation, possible site-specific EHR artifacts, and fairness across demographic groups.
Final justification
I recommend a score of 5: Accept. The paper is technically sound, and the additional pancreatic-cancer experiment, three-year follow-up cutoff analysis, calibration results, and rationale-quality analysis substantially addressed my main concerns. Some limitations remain, including low absolute PPV and limited strict shift and fairness evaluations, but I do not consider them sufficient grounds for rejection.
Formatting concerns
No
7 comments
Response to Reviewer eXjA - Part 1
We thank Reviewer eXjA for the suggestions and respond to the comments as follows.
Q1: The absolute predictive performance AUPRC and PPV remains low.
R1. The low absolute AUPRC and PPV are observed across all evaluated methods and reflect both the low outcome prevalence and the intrinsic difficulty of long-horizon prediction from routine EHR. The held-out evaluation cohorts have very low case prevalences: 0.70% for AD, 0.72% for PD, and 1.13% for ADRD. This is further compounded by the prediction horizon: five years before recorded disease onset, neurodegenerative signals captured in routine care are often sparse, indirect, and clinically nonspecific. Moreover, PPV and sensitivity are reported at 90% specificity, which corresponds to a 10% false-positive rate. When only approximately 1% of patients are future cases, false positives can therefore substantially outnumber true positives even for a model with improved discrimination. This explains why all methods have low absolute PPV.
AUPRC should therefore be interpreted relative to the outcome prevalence rather than against a fixed baseline of 0.5, as is customary for AUROC. For a non-informative ranking, the expected AUPRC is approximately the positive prevalence. OPHD increased AUPRC from prevalence baselines of 0.0070, 0.0072, and 0.0113 to 0.0236, 0.0238, and 0.0300 for AD, PD, and ADRD, respectively, corresponding to approximately 2.6- to 3.4-fold enrichment. Similarly, PPV at 90% specificity is approximately 2.3–2.9 times the underlying prevalence. These results indicate that our model identifies a subgroup with elevated future risk.
Importantly, our study follows a retrospective case-control design, as described in Appendix B, and aims to determine whether routinely collected EHR available at the reconstructed prediction time contains useful information for long-horizon early prediction. Accordingly, the model is intended to support early risk stratification and enrichment, which may help prioritize individuals for targeted screening or further assessment within an appropriate clinical workflow, rather than to serve as a definitive diagnostic test or a standalone screening decision rule. We will revise the manuscript to more clearly frame the results as retrospective evidence of long-horizon risk discrimination and risk enrichment in a case-control cohort study setting.
Response to Reviewer eXjA - Part 2
Q2: provide evidence that OPHD is robust under temporal shift, site shift, or evaluation on an independent external dataset
R2: The three cohorts are not clinically or temporally interchangeable. AD and PD are distinct diseases with different prodromal manifestations, underlying pathophysiological mechanisms, and disease progression patterns, while ADRD is a heterogeneous umbrella outcome that includes AD, vascular dementia, frontotemporal dementia, Lewy body dementia, and mixed dementias. Moreover, they are drawn from two different real-world EHR repositories, All of Us and OHSU, with distinct population compositions and substantial institutional variation in coding systems, documentation practices, and care delivery.
Furthermore, our focus on neurodegenerative diseases is deliberate. Neurodegenerative diseases constitute a major class of chronic progressive diseases, affecting large and growing patient populations and imposing substantial cognitive, motor, functional, and long-term care burdens. Earlier identification may inform care planning, monitoring, risk stratification, and disease-modifying clinical trials. At the same time, these diseases are challenging for long-horizon prediction because early signals in routine EHR are often sparse, heterogeneous, indirect, and clinically nonspecific. Moreover, unlike conditions with routinely measured indicators that provide relatively direct evidence of risk or disease status, neurodegenerative diseases generally lack a simple, low-cost clinical test for identifying long-term risk during the preclinical period. This combination of substantial burden and limited early observability makes AD, PD, and ADRD appropriate settings for evaluating whether follow-up trajectories can improve the interpretation of subtle prediction-time evidence and downstream predictive performance.
To directly evaluate generalization beyond neurodegenerative diseases, we added a two-year early prediction task for exocrine pancreatic cancer (EPC) using All of Us. EPC represents a substantially different disease domain and pathophysiology, while retaining the central challenge of identifying weak and nonspecific signals before overt diagnosis. We utilized the same cohort-construction, data-preparation, modeling, and evaluation pipeline as in the primary experiments with a hindsight cutoff of 180 days prior to the recorded onset. In this cohort, OPHD outperforms all evaluated baselines across all four metrics. The retained advantage under a distinct disease mechanism, temporal trajectory, and prediction horizon provides additional evidence that the framework is not restricted to neurodegenerative outcomes.
| Method (All of Us pancreatic cancer) | AUROC | AUPRC | Sens@90 | PPV@90 |
|---|---|---|---|---|
| GRAPE | 0.7082 | 0.0474 | 0.3689 | 0.0224 |
| MUSE | 0.6814 | 0.0237 | 0.2981 | 0.0230 |
| MOTOR | 0.6791 | 0.0397 | 0.2932 | 0.0207 |
| Zeroshot-LLM | 0.6594 | 0.0252 | 0.2083 | 0.0158 |
| Fewshot-LLM | 0.6713 | 0.0282 | 0.2216 | 0.0179 |
| Multi-sample | 0.6803 | 0.0296 | 0.2815 | 0.0213 |
| Best-of-K | 0.6926 | 0.0298 | 0.2743 | 0.0205 |
| ReConcile | 0.6785 | 0.0401 | 0.2867 | 0.0229 |
| DearLLM | 0.6948 | 0.0459 | 0.3172 | 0.0236 |
| OPHD | 0.7526 | 0.0912 | 0.4385 | 0.0253 |
To summarize, the OHSU-ADRD cohort already serves as an independent external-site evaluation: it is drawn from a different healthcare system than All of Us and targets a distinct, heterogeneous disease outcome. OPHD’s retained advantage on OHSU therefore provides evidence of robustness to both site and cohort shift. The newly added two-year early-prediction experiment for exocrine pancreatic cancer further changes the disease domain, clinical trajectory, and prediction horizon. Together, these evaluations show that the method remains effective across independent sites, disease domains, and temporal prediction settings, rather than being tied to a single cohort or five-year neurodegenerative prediction task.
Response to Reviewer eXjA - Part 3
Q3: The individual components build on established ideas in privileged information, self-distillation, and scorer-guided learning. Thus, the contribution reads as solid but somewhat incremental.
R3. The technical novelty does not lie in using these ingredients independently. Rather, OPHD introduces a new information-transfer mechanism for determining how noisy follow-up EHR should be transformed, filtered, and transferred back to the model’s current prediction-time reasoning trajectory.
First, OPHD transforms follow-up EHR into supervision through same-trajectory re-scoring. The current policy first generates an on-policy rationale using prediction-time EHR alone. Instead of allowing a privileged model to generate a separate rationale from prediction-time and follow-up EHR, OPHD keeps the realized rationale fixed and re-scores its token prefixes under two information conditions: the prediction-time reference view and the privileged follow-up view. The resulting token-level preference shifts measure how access to follow-up information changes the interpretation of the same prediction-time reasoning path. This is materially different from conventional privileged-information distillation, in which a student imitates an output generated with privileged inputs. Such direct imitation can transfer future-only evidence and create a train–test mismatch; OPHD instead transfers hindsight without introducing a future-conditioned target rationale.
Second, OPHD explicitly filters the privileged information before distillation. Follow-up EHR is not assumed to be reliable supervision, because it may contain routine-care events and unrelated comorbidities. OPHD therefore constructs multiple perturbed privileged views and evaluates whether each token-level preference shift is both salient and stable across these views. The hindsight weight combines the magnitude of the average shift with a penalty for cross-view variability. Consequently, follow-up information is not transferred uniformly: only reasoning components that receive consistent support across perturbed follow-up trajectories are emphasized. This converts noisy longitudinal records into selective token-level supervision rather than treating the entire follow-up record as a trustworthy teacher signal.
Third, OPHD determines which of these stable hindsight signals should be transferred according to their task-specific predictive value. The task-grounded scorer does not simply provide an absolute confidence score or a sequence-level correctness reward. Instead, it measures the incremental label support contributed by the rationale beyond the prediction-time EHR alone. This distinction is important because a high prediction probability may arise from an already informative EHR, even when the rationale itself contributes little. By combining this rationale-level gain with the token-level hindsight stability weight, OPHD prioritizes reasoning components that are simultaneously supported by follow-up trajectories, robust to follow-up perturbations, and useful for downstream risk discrimination.
Finally, the selected information is transferred back to the current policy through distributional distillation on its own on-policy trajectory. The policy is trained to approach the perturbed privileged distributions only at the token positions identified by the joint hindsight and task-grounded weighting. These components address three coupled problems that are not resolved by standard privileged-information learning, self-distillation, or scorer-guided optimization alone: avoiding imitation of future-conditioned rationales, suppressing noisy hindsight signals, and ensuring that the retained token-level supervision is relevant to the downstream prediction task.
- Rating
- 3/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes On-Policy Hindsight Distillation (OPHD), a self-distillation method for early chronic disease risk prediction from EHRs. OPHD uses follow-up records as privileged training-time evidence to improve LLM-generated rationales, while relying only on prediction-time EHR data at inference. It identifies stable, salient token-level preference shifts across perturbed privileged views and distills them into the rationale generator, with a task-grounded scorer emphasizing rationales that improve risk discrimination. Experiments on Alzheimer’s, Parkinson’s, and ADRD cohorts show consistent gains over EHR and LLM reasoning baselines.
Strengths and weaknesses
Strengths:
- The paper addresses a key challenge in long-horizon clinical risk prediction: early disease signals are sparse, indirect, and confounded by healthcare utilization patterns.
- The use of follow-up EHR as privileged training-time information is well motivated and clinically intuitive, especially through the analogy to how clinicians learn from patient follow-up.
- The task-grounded scorer is well designed: using incremental label-support gain focuses distillation on rationales that add predictive value beyond the original EHR.
- The ablation study is comprehensive, with the Uniform Privileged Distillation variant serving as a useful control showing that selective weighting, not privileged information alone, drives the gains.
Weaknesses:
- The absolute predictive performance remains low, with AUPRC values around 0.01-0.03 across cohorts, raising concerns about practical clinical utility despite consistent relative gains.
- Even at 90% specificity, PPV remains very low, suggesting the model would still produce many false positives per true positive in realistic screening settings.
- The evaluation is limited to three neurodegenerative disease cohorts with similar temporal characteristics, weakening claims about broader generalizability. 4.The role of the frozen re-scoring model is underspecified: the paper does not clarify whether it is fixed at initialization or periodically synchronized with the policy model. If the re-scoring model is never updated, its token-level preferences may become stale; if it is updated, the training targets become nonstationary.
Questions
- How is the follow-up cutoff t1 chosen in prospective deployment, where disease onset and the temporal anchor for defining follow-up are unknown?
- Can the authors show qualitative examples of high-weight hindsight tokens or rationale segments, and whether they correspond to clinically interpretable concepts?
Limitations
Yes
Formatting concerns
No
4 comments
Response to Reviewer kdSv - Part 1
We thank Reviewer kdSv for the suggestions and respond to the comments as follows.
Q1: The absolute predictive performance AUPRC and PPV remains low.
R1. The low absolute AUPRC and PPV are observed across all evaluated methods and reflect both the low outcome prevalence and the intrinsic difficulty of long-horizon prediction from routine EHR. The held-out evaluation cohorts have very low case prevalences: 0.70% for AD, 0.72% for PD, and 1.13% for ADRD. This is further compounded by the prediction horizon: five years before recorded disease onset, neurodegenerative signals captured in routine care are often sparse, indirect, and clinically nonspecific. Moreover, PPV and sensitivity are reported at 90% specificity, which corresponds to a 10% false-positive rate. When only approximately 1% of patients are future cases, false positives can therefore substantially outnumber true positives even for a model with improved discrimination. This explains why all methods have low absolute PPV.
AUPRC should therefore be interpreted relative to the outcome prevalence rather than against a fixed baseline of 0.5, as is customary for AUROC. For a non-informative ranking, the expected AUPRC is approximately the positive prevalence. OPHD increased AUPRC from prevalence baselines of 0.0070, 0.0072, and 0.0113 to 0.0236, 0.0238, and 0.0300 for AD, PD, and ADRD, respectively, corresponding to approximately 2.6- to 3.4-fold enrichment. Similarly, PPV at 90% specificity is approximately 2.3–2.9 times the underlying prevalence. These results indicate that our model identifies a subgroup with elevated future risk.
Importantly, our study follows a retrospective case-control design, as described in Appendix B, and aims to determine whether routinely collected EHR available at the reconstructed prediction time contains useful information for long-horizon early prediction. Accordingly, the model is intended to support early risk stratification and enrichment, which may help prioritize individuals for targeted screening or further assessment within an appropriate clinical workflow, rather than to serve as a definitive diagnostic test or a standalone screening decision rule. We will revise the manuscript to more clearly frame the results as retrospective evidence of long-horizon risk discrimination and risk enrichment in a case-control cohort study setting.
Q2: The role of the frozen re-scoring model is underspecified.
R2. In our implementation, the re-scoring model is a frozen copy of the same pretrained LLM used to initialize the rationale generator and remains fixed throughout training; it is not periodically synchronized. Importantly, freezing the re-scoring model parameters does not make the token-level preferences stale, because these preferences are conditional on the input context and rationale prefix. At each training iteration, a new on-policy rationale is generated, and the re-scoring model recomputes the token distributions for its current prefixes under the patient-specific prediction-time context and each newly sampled perturbed follow-up context. Thus, although the model parameters remain fixed, the token-level preference distributions and hindsight targets vary dynamically with the EHR context, the perturbed privileged view, and the generated rationale.
Response to Reviewer kdSv - Part 2
Q3: The evaluation is limited to three neurodegenerative disease cohorts with similar temporal characteristics, weakening claims about broader generalizability.
R3. The three cohorts are not clinically or temporally interchangeable. AD and PD are distinct diseases with different prodromal manifestations, underlying pathophysiological mechanisms, and disease progression patterns, while ADRD is a heterogeneous umbrella outcome that includes AD, vascular dementia, frontotemporal dementia, Lewy body dementia, and mixed dementias. Moreover, they are drawn from two different real-world EHR repositories, All of Us and OHSU, with distinct population compositions and substantial institutional variation in coding systems, documentation practices, and care delivery.
Furthermore, our focus on neurodegenerative diseases is deliberate. Neurodegenerative diseases constitute a major class of chronic progressive diseases, affecting large and growing patient populations and imposing substantial cognitive, motor, functional, and long-term care burdens. Earlier identification may inform care planning, monitoring, risk stratification, and disease-modifying clinical trials. At the same time, these diseases are challenging for long-horizon prediction because early signals in routine EHR are often sparse, heterogeneous, indirect, and clinically nonspecific. Moreover, unlike conditions with routinely measured indicators that provide relatively direct evidence of risk or disease status, neurodegenerative diseases generally lack a simple, low-cost clinical test for identifying long-term risk during the preclinical period. This combination of substantial burden and limited early observability makes AD, PD, and ADRD appropriate settings for evaluating whether follow-up trajectories can improve the interpretation of subtle prediction-time evidence and downstream predictive performance.
To directly evaluate generalization beyond neurodegenerative diseases, we added a two-year early prediction task for exocrine pancreatic cancer (EPC) using All of Us. EPC represents a substantially different disease domain and pathophysiology, while retaining the central challenge of identifying weak and nonspecific signals before overt diagnosis. We utilized the same cohort-construction, data-preparation, modeling, and evaluation pipeline as in the primary experiments with a hindsight cutoff of 180 days prior to the recorded onset. In this cohort, OPHD outperforms all evaluated baselines across all four metrics. The retained advantage under a distinct disease mechanism, temporal trajectory, and prediction horizon provides additional evidence that the framework is not restricted to neurodegenerative outcomes.
| Method (All of Us pancreatic cancer) | AUROC | AUPRC | Sens@90 | PPV@90 |
|---|---|---|---|---|
| GRAPE | 0.7082 | 0.0474 | 0.3689 | 0.0224 |
| MUSE | 0.6814 | 0.0237 | 0.2981 | 0.0230 |
| MOTOR | 0.6791 | 0.0397 | 0.2932 | 0.0207 |
| Zeroshot-LLM | 0.6594 | 0.0252 | 0.2083 | 0.0158 |
| Fewshot-LLM | 0.6713 | 0.0282 | 0.2216 | 0.0179 |
| Multi-sample | 0.6803 | 0.0296 | 0.2815 | 0.0213 |
| Best-of-K | 0.6926 | 0.0298 | 0.2743 | 0.0205 |
| ReConcile | 0.6785 | 0.0401 | 0.2867 | 0.0229 |
| DearLLM | 0.6948 | 0.0459 | 0.3172 | 0.0236 |
| OPHD | 0.7526 | 0.0912 | 0.4385 | 0.0253 |
Response to Reviewer kdSv - Part 3
Q4: How is the follow-up cutoff chosen in prospective deployment, where disease onset and the temporal anchor for defining follow-up are unknown?
R4. Thank you for raising this point. The follow-up cutoff is a retrospective training-time construct and is neither selected nor required in prospective deployment.
Consistent with retrospective case-control study designs, as described in Appendix B, the disease index time has already been observed. Early prediction therefore aims to make a prediction at , ahead of the recorded index time, and the proposed model leverages an intermediate follow-up interval during training. In the main experiments, is set five years before the recorded index time, while is set one year before the index time. Considering the long progression of neurodegenerative diseases, a five-year horizon is a commonly used prediction window in related studies. This cutoff provides informative training-time hindsight while preserving a temporal gap from the recorded diagnosis and reducing reliance on near-diagnosis evidence.
At inference, the current clinical time serves as the prediction time, and the model uses only EHR available up to that time. The future disease onset, , follow-up EHR, perturbed privileged views, and hindsight re-scoring are neither known nor required at inference. Hindsight is used only during retrospective training to improve how the model interprets prediction-time evidence. After training, the deployed rationale generator and task-grounded scorer operate solely on the patient’s currently available EHR.
Thus, stating that prediction is performed “five years before onset” describes how the retrospective cohort and evaluation task are constructed; it does not assume that the future onset time is known at evaluation.
Q5: Qualitative examples of high-weight hindsight tokens or rationale segments, and whether they correspond to clinically interpretable concepts
R5: Individual tokens may be subword fragments; we aggregate adjacent high-weight tokens into readable rationale spans. Importantly, the high-weight token identifies a position where follow-up context induces a large and stable change in the token distribution, indicating that the current on-policy rationale requires hindsight-guided adjustment.
In an AD case with vascular and metabolic burden, obstructive sleep apnea, dizziness and vertigo, and chronic multisite pain in the prediction-time EHR, the initial on-policy rationale characterized these observations as “a generalized aging phenotype” and “a broad pattern of chronic multisystem aging.” This high-weight region indicated that the initial interpretation required substantial hindsight-guided adjustment: it treated the vascular, metabolic, sleep-related, and somatic abnormalities primarily as diffuse age-related background. After hindsight-guided training, the regenerated rationale instead described the record as “a chronic, interwoven physiological strain across multiple systems that could contribute to reduced resilience and gradual erosion of brain reserve over time.” It recognizes that the persistent co-occurrence of vascular stress, metabolic dysregulation, sleep-related hypoxia, and recurrent somatic symptoms may reflect a chronic, low-grade burden across multiple physiological systems, providing a more informative patient-level interpretation than a generic description of normal aging.
In a PD case with shoulder stiffness and pain, together with gait abnormalities and subtle tremor-related complaints in the prediction-time EHR, the initial on-policy rationale characterized these observations as “common musculoskeletal and age-related mobility complaints.” This phrase received a high hindsight weight. After hindsight-guided training, the regenerated rationale instead described them as “a persistent musculoskeletal–motor pattern involving shoulder stiffness, gait changes, and subtle tremor-related symptoms”. This revision is more informative because shoulder pain or stiffness alone is highly nonspecific, whereas its repeated co-occurrence with gait and tremor-related abnormalities may form a coherent early motor pattern.
These examples illustrate that high-weight hindsight spans identify where an initially generic interpretation should be substantially revised. The resulting updates correspond to interpretable relationships among weak prediction-time signals. We will add these representative, de-identified examples of high-weight regions in the revised appendix.
Dear Reviewer kdSv,
As the discussion period draws to a close, we wanted to ask whether our response has addressed your concerns. Please let us know if there are any remaining questions we can further clarify. Thank you!
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes On-Policy Hindsight Distillation, a method that uses follow-up EHR information to train an LLM that achieves better performance, despite still only using prediction time EHR. The proposed method achieves better performance than baselines.
Strengths and weaknesses
Strengths
- The paper identifies an important part of information that can be utilized for improving the performance of LLMs, which is the follow-up EHR between prediction-time and disease onset time.
- The proposed method consistently achieves better performance than baselines, indicating its effectiveness.
- The paper constructed a dedicated benchmark for testing the method, which itself could be a contribution.
Weaknesses
- The paper uses only Qwen3-4B-Instruct-2507 as the baseline method, which does not provide enough evidence for the effectiveness of proposed method on other model sizes and families.
- The paper does not use any other common benchmarks in the field, and it does not provide any justification for this choice.
I would consider raising my score, if these two weaknesses have been properly addressed.
Questions
- If the method is applied on other LLMs (changing either the rationale generator or the scorer), would the performance advantage be maintained?
- Is it possible to test the proposed method on different benchmarks?
- Many of the baseline method's performance (especially AUROC) falls below the Zeroshot-LLM or Multi-sample method. Could the authors provide more insights or examples showing why more complicated methods (GRAPE, MUSE, MOTOR) are even less effective than naive baselines?
Limitations
Yes.
Final justification
The authors have provided additional experiments to address my concerns.
Formatting concerns
No.
3 comments
Rebuttal
We thank Reviewer G94i for the suggestions and respond to the comments as follows.
Q1: Other LLMs (changing either the rationale generator or the scorer)
R1: For the rationale generator, we would respectfully highlight that Appendix F.2 and Figure 6 provide a backbone analysis. Specifically, we replace the default Qwen3-4B generator with Gemma3-4B, Qwen3-8B, and Ministral-3 8B (newly added) while following the same training and evaluation protocol on the ADRD cohort. The results are shown below.
| Rationale generator (ADRD cohort) | AUROC | AUPRC | Sens@90 | PPV@90 |
|---|---|---|---|---|
| Gemma3-4B | 0.6253 | 0.0319 | 0.2238 | 0.0279 |
| Qwen3-4B | 0.6360 | 0.0300 | 0.2344 | 0.0262 |
| Qwen3-8B | 0.6506 | 0.0341 | 0.2587 | 0.0318 |
| Ministral-3 8B | 0.6535 | 0.0317 | 0.2542 | 0.0294 |
OPHD achieves comparable AUROC, AUPRC, sensitivity at 90% specificity, and PPV at 90% specificity across all four backbones, with the larger 8B models providing only modest additional improvements. The consistency across Gemma, Qwen, and Ministral model families, as well as across 4B and 8B scales, indicates that the proposed hindsight-distillation mechanism is not tied to a particular rationale-generator backbone.
We also conduct a complementary scorer analysis by fixing the Qwen3-4B rationale generator and replacing the default Qwen3-0.6B scorer with two compact models from different families: LFM2.5-1.2B-Instruct and Gemma 3-1B. Each scorer is retrained within the OPHD pipeline because it provides both the task-grounded feedback during training and the final risk prediction.
| Scorer (ADRD cohort) | AUROC | AUPRC | Sens@90 | PPV@90 |
|---|---|---|---|---|
| Qwen3-0.6B | 0.6360 | 0.0300 | 0.2344 | 0.0262 |
| LFM2.5-1.2B-Instruct | 0.6415 | 0.0318 | 0.2516 | 0.0284 |
| Gemma 3-1B | 0.6339 | 0.0306 | 0.2385 | 0.0297 |
As shown in the table, performance remains comparable across all three scorers. LFM2.5-1.2B-Instruct achieves the strongest overall results, while the 0.6B Qwen scorer remains competitive despite its substantially smaller size. Unlike the rationale generator, the scorer does not perform open-ended clinical reasoning or text generation; it only estimates the outcome from the prediction-time EHR and the generated rationale and provides a scalar task-grounded feedback signal. This comparatively constrained classification role can be handled effectively by compact language models. The consistency across Qwen, LFM, and Gemma scorers further indicates that the performance of OPHD is not tied to a particular scorer family and supports the use of a small scorer as a computationally efficient design choice.
Overall, across LLMs from different model families used as either the rationale generator or the scorer, OPHD consistently outperforms the baselines, demonstrating that its performance advantage is not tied to a particular model backbone.
Q2: Test the proposed method on different benchmarks
R2: To the best of our knowledge, existing public EHR benchmarks are not directly aligned with the long-horizon EHR-based early prediction setting considered in our study. Existing clinical datasets differ substantially from our target setting. Acute-care EHR benchmarks such as MIMIC, eICU, and HiRID are largely hospitalization- or ICU-visit-centered rather than natural longitudinal EHR populations; their observation windows, event density, and outcomes are shaped by specific encounter episodes and are therefore more suitable for acute-care prediction tasks. Disease-specific resources such as PPMI, PDBP, and ADNI emphasize standardized cognitive assessments and recruit eligible patients for close monitoring with imaging, biospecimens, genetic data, and other biomarkers. However, these cohorts are protocol-driven with designated healthcare visits and measurements, rather than routine real-world EHR benchmarks.
Our focus on neurodegenerative diseases is deliberate. AD, PD, and related dementias affect large and rapidly growing patient populations suffering from progressive cognitive and functional deterioration, where earlier identification may support care planning and monitoring, risk stratification, and disease-modifying clinical trials. At the same time, these diseases are particularly challenging for long-horizon prediction because they progress over long periods, during which early signals are often sparse, heterogeneous, indirect, and clinically nonspecific. In contrast to diseases for which routinely measured indicators can provide relatively direct evidence of risk or disease status, neurodegenerative diseases generally lack a single simple and low-cost clinical test that reliably identifies long-term risk during the preclinical period. This combination of substantial impact and limited early observability makes neurodegenerative diseases a particularly appropriate setting for evaluating whether follow-up trajectories can improve the interpretation of subtle prediction-time evidence and, ultimately, downstream predictive performance.
Importantly, although no predefined community benchmark exists for the studied problem, our evaluation is not limited to a single institution-specific dataset. We included All of Us, one of the largest nationwide research programs linking longitudinal EHR with participant-level health information, which is available to registered researchers through a standardized controlled-access process and the secure Researcher Workbench. We further evaluated the method on an independent OHSU EHR cohort. Together, these two data sources support three disease cohorts: AD, PD, and ADRD. We believe this multi-source, multi-disease evaluation provides a meaningful robustness assessment in the absence of a directly aligned public benchmark.
In response to the reviewer’s suggestion, we further evaluated OPHD on a supplementary three-year ADRD early-risk prediction cohort constructed from MIMIC-IV using the same cohort-construction and data-preparation pipeline as in the main experiments. We used a three-year rather than five-year prediction horizon to accommodate MIMIC-IV’s hospitalization-centered sampling frame and comparatively limited longitudinal coverage. Using the same OPHD framework and evaluation protocol, OPHD achieved the best performance among all evaluated methods across AUROC, AUPRC, Sens@90, and PPV@90, suggesting that its performance advantage is preserved under a different data-generating process and cohort structure.
| Method (MIMIC-IV ADRD) | AUROC | AUPRC | Sens@90 | PPV@90 |
|---|---|---|---|---|
| GRAPE | 0.6561 | 0.1054 | 0.2056 | 0.1172 |
| MUSE | 0.6294 | 0.0780 | 0.1928 | 0.0975 |
| MOTOR | 0.6077 | 0.0628 | 0.1749 | 0.0931 |
| Zeroshot-LLM | 0.6142 | 0.0757 | 0.1873 | 0.0963 |
| Fewshot-LLM | 0.6218 | 0.0792 | 0.1915 | 0.1008 |
| Multi-sample | 0.6485 | 0.1055 | 0.2421 | 0.1106 |
| Best-of-K | 0.6366 | 0.0954 | 0.2446 | 0.1126 |
| ReConcile | 0.6293 | 0.0851 | 0.1975 | 0.1047 |
| DearLLM | 0.6214 | 0.1049 | 0.2183 | 0.1094 |
| OPHD | 0.6785 | 0.1192 | 0.3257 | 0.1262 |
Q3: More insights or examples showing why more complicated methods (GRAPE, MUSE, MOTOR) are even less effective than naive baselines
R3: The main issue is not model complexity, but the supervision available for learning from noisy long-horizon EHR. GRAPE and MUSE learn graph-based representations from structured patient–feature relationships, while MOTOR learns general temporal EHR representations through pretraining. However, for the target disease, these methods ultimately rely mainly on prediction-time EHR and outcome labels, without intermediate supervision indicating which early observations are genuinely predictive.
This limitation is especially important in long-horizon prediction. Several years before diagnosis, EHRs might contain common comorbidities, medications, and healthcare-utilization events that may be unrelated to the future disease outcome, whereas truly informative signals are sparse, weak, and clinically nonspecific. The final outcome label indicates whether the disease eventually occurs, but does not reveal which early events are meaningful and which are incidental. Consequently, even sophisticated graph or pretrained EHR models may emphasize dominant but nonspecific statistical patterns and struggle to distinguish useful weak signals from background noise. This is the central challenge described in our motivation.
Zero-shot and Multi-sample methods are simple only in terms of task-specific training. They still benefit from clinical and semantic knowledge acquired during large-scale LLM pretraining, which can help connect several heterogeneous and individually nonspecific observations into a coherent clinical pattern. Multi-sample further reduces dependence on a single incomplete interpretation. Therefore, the results mainly reflect differences in available knowledge and supervision, rather than more complicated architectures being inherently less effective.
Thanks for addressing my concerns. I have raised my score.
Response to Reviewer G94i
We are glad that our response has addressed your concerns. Thank you so much for raising your score, and we sincerely appreciate your time, thoughtful feedback, and recognition of our work.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Response to AC
We thank the Area Chair and all reviewers for the time and effort they devoted to evaluating our submission and for their constructive feedback. We have responded to each reviewer comment point by point below. We are glad that our responses addressed the concerns raised by Reviewers G94i and eXjA, and we appreciate their increased scores! Below, we provide a brief summary addressing the meta-review, with further details available in our complete reviewer-specific responses.
Models and benchmarks (Reviewer G94i, Q1–Q2). We evaluated four rationale generators spanning Gemma, Qwen, and Ministral families, as well as three compact scorers from Qwen, LFM, and Gemma. OPHD retains comparable performance and its advantage over the baselines across these configurations. To the best of our knowledge, existing established public EHR benchmarks are not directly aligned with the long-horizon, EHR-based early-prediction setting considered in our study, as their settings and task definitions differ substantially from ours. We provided a detailed justification in our response to Reviewer G94i (Q2) and further evaluated OPHD on a supplementary three-year ADRD early-risk prediction cohort constructed from MIMIC-IV, where it achieves the best performance across all four metrics.
Absolute performance and clinical utility (Reviewer kdSv, Q1; Reviewer eXjA, Q1 and Q5). The low absolute AUPRC and PPV are observed across all evaluated methods and reflect both the low outcome prevalence and the intrinsic difficulty of long-horizon prediction from routine EHR. The held-out evaluation cohorts have very low case prevalences: 0.70% for AD, 0.72% for PD, and 1.13% for ADRD. OPHD achieves AUPRC values corresponding to approximately 2.6- to 3.4-fold enrichment over the prevalence baselines. Similarly, PPV at 90% specificity is approximately 2.3–2.9 times the underlying prevalence. These results indicate that our model identifies a subgroup with elevated future risk. Importantly, our study follows a retrospective case-control design, and the model is intended to support early risk stratification and enrichment, which may help prioritize individuals for targeted screening or further assessment within an appropriate clinical workflow. We also provide calibration analyses in our response to Reviewer eXjA (Q5): predicted risk strata exhibit monotonic increases in observed event rates across all three cohorts, and the mean calibrated predictions are broadly consistent with the empirical event rates in most strata.
Generalization (Reviewer kdSv, Q2; Reviewer eXjA, Q2). Neurodegenerative diseases provide a particularly appropriate primary testbed because their long preclinical periods contain sparse, heterogeneous, indirect, and clinically nonspecific EHR signals. Moreover, the three original cohorts are not clinically or temporally interchangeable: AD and PD have distinct prodromal manifestations, pathophysiological mechanisms, and progression patterns, whereas ADRD is a heterogeneous outcome encompassing multiple dementia subtypes. The evaluation also includes an independent external data source and site through the OHSU cohort. To further assess generalization beyond neurodegenerative diseases, we added a two-year early-prediction task for exocrine pancreatic cancer (EPC) using All of Us, where OPHD outperforms all evaluated baselines. Together, these evaluations show that the method remains effective across independent sites, disease domains, and temporal prediction settings. The corresponding results are provided in our responses to Reviewer kdSv (Q2) and Reviewer eXjA (Q2).
Frozen re-scoring model (Reviewer kdSv, Q3). We would like to clarify that the re-scoring model is a frozen copy of the same pretrained LLM used to initialize the rationale generator and remains fixed throughout training. Importantly, freezing the re-scoring model parameters does not make the token-level preferences stale, because these preferences are conditional on the input context and rationale prefix. At each training iteration, a new on-policy rationale is generated, and the re-scoring model recomputes the token distributions for its current prefixes under the patient-specific prediction-time context and each newly sampled perturbed follow-up context. Thus, although the model parameters remain fixed, the token-level preference distributions and hindsight targets vary dynamically with new EHR context, the perturbed privileged view, and the generated rationale. This dynamic, context-dependent recomputation prevents the re-scoring signal from becoming stale.
We thank all reviewers again for their constructive feedback. We look forward to hearing from Reviewer kdSv and would be happy to address any further questions!
Sincerely,
Authors