potentialpaper

Ensemble Selective Classification

Sinian Zhang, Chongwei Chen, Guanchen Li, Ju Sun

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. This paper proposes a post-hoc ensemble selective-classification framework that learns to combine diverse confidence scores with a small labeled calibration set, improving risk-coverage performance without retraining the base classifier.

Abstract. Selective classification (SC) improves model reliability by allowing a classifier to abstain on potentially wrong predictions. In the practical post-hoc setting, where the base classifier is fixed and often accessed as a black box, many confidence scores have been proposed, yet no single score is consistently best across models, datasets, and deployment shifts. We address this limitation by proposing, to our knowledge, the first ensemble framework for post-hoc SC, which learns to combine a diverse set of existing confidence scores using a small labeled calibration set drawn from the deployment distribution. We cast this problem as learning to separate correct from incorrect predictions of the base classifier, and train the ensemble selector with SoftRank-AURC, a differentiable soft-rank plug-in objective for the area under the risk-coverage curve (AURC), the standard evaluation metric for SC. We also study the SElective classifier LEarning (SELE) loss as an alternative training objective. For SoftRank-AURC, our analysis suggests that the learned ensemble may be competitive with a strong individual scorer, up to estimation error and smoothing bias. Across 15 image and NLP classification tasks, with additional LLM multiple-choice experiments, the proposed method is consistently strong and often outperforms the best individual score, particularly under distribution shift, establishing ensemble post-hoc SC as a simple and effective way to improve reliability without retraining the base classifier.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
3 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 4 reviews · OpenReview

Updated 25 Nov 2026, 03:45 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This paper proposes a new post-hoc method for selective classification, aggregating scores obtained from different models to optimize an AURC metric. Some theoretical results are presented to support the method and numerical experiments validate it.

Strengths:

  • The method is intuitive, sound, and involves some degree of novelty
  • The paper addresses a practically relevant problem
  • The empirical results are promising

Weaknesses:

  • The method should be compared against additional baselines
  • The presentation could be improved. The writing is verbose and does not always explain clearly.

The reviews are positive and clearly leaning towards acceptance. The referees had some questions and concerns, which appear to have been sufficiently addressed during the rebuttal period. If the paper is accepted, the camera-ready version should reflect the changes discussed and agreed upon during the discussion with the referees.

Final justification

The reviews are positive and unanimous in leaning towards acceptance, with the referees' remaining questions and concerns sufficiently addressed during the rebuttal period.

Area Chair 8bNr · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

This paper proposes a new post-hoc method for selective classification, aggregating scores obtained from different models to optimize an AURC metric. Some theoretical results are presented to support the method and numerical experiments validate it.

Strengths:

  • The method is intuitive, sound, and involves some degree of novelty
  • The paper addresses a practically relevant problem
  • The empirical results are promising

Weaknesses:

  • The method should be compared against additional baselines
  • The presentation could be improved. The writing is verbose and does not always explain clearly.

The reviews are positive and clearly leaning towards acceptance. The referees had some questions and concerns, which appear to have been sufficiently addressed during the rebuttal period. If the paper is accepted, the camera-ready version should reflect the changes discussed and agreed upon during the discussion with the referees.

Final justification

The reviews are positive and unanimous in leaning towards acceptance, with the referees' remaining questions and concerns sufficiently addressed during the rebuttal period.

1 comment
Authors · CommentOpenReview ↗

We thank the AC for the summary and for the clear statement of what would need to happen for the paper to be acceptable. We have posted individual responses to all four reviewers; below we summarize how the three weaknesses named in the meta review are addressed.

We ran 44 new experiments during the rebuttal period—a SELE-MLP baseline, an analysis of the learned ensemble weights, a normalization ablation, and a corrupted-scorer robustness sweep — and two theoretical claims were restated more precisely.

The method should be compared against additional baselines

We added SELE-MLP (the AURC-MLP architecture with SELE as its loss), requested by Reviewer infM, and ran it on all 15 image and NLP datasets at every calibration size. Optimizing the AURC surrogate is better on 10/15 datasets. The full table is in our response to Reviewer infM.

The presentation could be improved. The writing is verbose and does not always explain clearly.

We will revise paper thoroughly for better clarity , including but not limited to: restructuring and streamlining Section 4, adding a flowchart of the training procedure, defining SELE and MAD at first use, adding error bars and explicit method marking to Figure 1, and reporting training and inference times in the main text.

The technical novelty seems more limited than the writing may suggest.

We believe this impression comes mainly from Reviewer jj1K (their Weakness 3 / Question 1) about the non-vanishing remainder term in Eq. (3.13). We will present an improved form of the result and also discuss the precise implications in our revision. Our response to Reviewer jj1K gives the details.

We are happy to provide any further results or clarification during the discussion period.

Reviewer YgSBOpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
2/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper presents a simple but novel idea: doing post-hoc selective classification (i.e., abstaining from classifying when confidence is low) based on combining score functions (hence the word ensembling in the title). The training algorithm focuses on soft-rank area under the risk-coverage curve. Experiments are conducted on image/NLP and LLM mc data sets. Main results show that the proposed method improves on AURC, the paper shows several ablations and analysis on LLM data.

Strengths and weaknesses

The idea is simple but it clearly has merit. Overall I like the paper, but find it quite a hard read, even though the idea is simple. This may be due to me not being an expert in selective classification, or due to the writing style (or both). It took me quite a long time to properly grasp how the method works, how the experiments are designed, and what to conclude from them. Perhaps this is related to the number of abbreviations used or the convoluted and verbose writing style. Also, I find the argumentation for design choices sometimes limited, which make the method seem a bit 'engineered'. Summarizing:

  1. I find the method to be simple but hard to understand at first (and second) read, it requires better explanation, perhaps using a figure/flowchart of some sort can help to illustrate the method?
  2. Section 4 has too many abbrevatiations and the experimental design needs too many words to explain
  3. Section 4 attempts to bring structure, but fails to do so in my opinion, try to reconsider its structure and presentation, as I get lost in this section.
Questions

I think the paper requires signficant thought on how to restructure and rewrite it in such a way that it becomes easier to interpret. I hope this is doable during the limited rebbutal period.

Minor comments:

  1. This did not (and will not) affect my score, but I found it confusing the word "ensemble" was used for a method that has nothing to do with ensemble learning. From the title I was expecting such a connection, and in the last paragraph of section 2 you do link to ensmeble methods. It is not clear to me how your work is related to ensemble learning, could you learn a base learner for each score metric?
  2. Section 3: introduce subsections
  3. Section 3.1: why is normalization of scores needed?
  4. "(...) especially useful when data are scarce and/or the deployment distribution can drift over time and frequent re-calibration might be neccesary." - maybe interesting for future research. You do not discuss future research at all in Section 5, would be good to add
  5. Table 1 and 2, it took me some time to understand all rows (RLmaxRL_\text{max}, SRmaxSR_\text{max}, etc.), the rows are individual scores right? Can you present this as an ablation, as your method also uses all individual scores?
  6. Figure 1: what is the variance over the results? Maybe indicate using shading or error bars? It is not clear what is your method and what method is a benchmark. I know you state this in the text, but there too many abbreviations and I get lost
  7. It would be good to report training and inference times compared to the benchmarks in the main text, as you do discuss it as limitation
Limitations

yes, but computational times could be reported too

Final justification

Bumped score from 3 to 4. Not higher as it is hard to confirm if clarity will actually be improved and the rebuttal did not convince me otherwise.

Formatting concerns

no

3 comments
Authors · CommentOpenReview ↗

We thank the reviewer for the positive assessment of the idea and, in particular, for the candid feedback on readability. We agree that the presentation can be streamlined, which we will take seriously during revision. Below, we respond to all the weaknesses and questions.

Weaknesses 1–3 / Questions — Readability, structure, and the presentation of Section 4

Following the reviewer's suggestion, we will

  1. Add a flowchart to illustrate our main method;
  2. Use tables to replace the lengthy text on the experimental design, and to summarize abbreviations for easy references;
  3. Restructe our technical flow, in particular Sec. 4, to minimize confusion;

and, thoroughly polish the language for better readability.

Minor 1 — Why the method is called an "ensemble"

  • We use the term "ensemble learning" in the standard machine learning sense: combining multiple weak learners/predictors for a stronger one. Here, the weak learners are the base selectors with learnable thresholds.
  • We agree that the style of our algorithm is different from representative textbook ensemble learning methods, such as boosting and random forests, where the base learners are trained independently or sequentially—because they typically need to select the base learners from a complex, infinite hypothesis class. For us, thanks to the small number of weak learners with simple learnable parameters only, we can perform joint optimization of the thresholds of the base selectors and the ensemble weights directly.

Minor 2 — Subsections in Section 3

We will add a summary paragraph at the beginning of Section 3.

Minor 3 — Why score normalization is needed

  • Since these scorers may assign confidence values of different scales and distributions, we need to normalize them to a common scale and similar distributions before combining them.
  • To normalize each scorer, it is tempting to consider the standard zero-mean-unit-variance normalization. But both the mean and the variance are sensitive to outlying probability masses, and they could be ill-defined for certain heavy-tailed distributions. Thus, we use a robust alternative based on the median and the median absolute deviation (MAD).

Minor 4 — Future research directions in Section 5

We will mention this in Section 5.

Minor 5 — Individual scores in Tables 1 and 2

  • Yes, the rows are indeed the individual base scores.
  • Thanks for suggesting moving them into ablation study! But, we would like to keep them there, as they are important baseline methods. We want to confirm our ensemble methods always outperform the best base selectors, on each task—the very reason we want to pursue an ensemble approach.

Minor 6 — Variance and method identification in Figure 1

  • We report the variance in the appendix; we will consider moving them to the main body using shading or error bars as suggested during revision, if space allows;
  • We will distinguish our methods from baselines using visible colored shading and/or different line styles in the figure to improve the readability.

Minor 7 / Limitations — Training and inference times

We will do it alongside the discussion of limitation in our revision.


We thank the reviewer again for this review. The comments on readability are the ones we will act on most extensively in the revision, since they concern how accessible the method is to readers outside selective classification. We hope the responses above address the concerns raised, and we are happy to provide further clarification during the discussion period.

Reviewer YgSB · CommentOpenReview ↗

Thank you for the detailed response.

Considering minor point 5: I am not considering to move the result to an appendix, I simply did not understand the presentation, so I was wondering if this result could be considered an ablation.

Nonetheless, my main questions are resolved. I will consider increasing my score after the rebuttal period, if the discussion with the other reviewers does not reveal any additional significant concerns.

Authors · CommentOpenReview ↗

We thank the reviewer for the clarification, the helpful comments on the presentation, and the consideration of a higher score. we will improve the clarity of the presentation in the revised manuscript based on the reviewer's suggestions. We are pleased that the main questions have been resolved.

Reviewer 4RRDOpenReview ↗
Rating
5/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper focuses on the post-hoc selective classification task and proposes that traditional single confidence scores exhibit unstable performance and lack universality across different models, datasets, and distribution shifts. To address this issue, the paper firstly proposes the ensemble framework in the context of post-hoc selective classification, which combines multiple confidence scores. This framework leverages a small labeled calibration set from the deployment distribution to dynamically adapt to diverse scenarios. Furthermore, it introduces the SoftRank-AURC loss, which directly associates the Area Under the Risk-Coverage Curve (AURC) with the ranking of sample confidence scores to directly optimize classification performance. The proposed method serves as a plug-and-play post-processing approach, reducing computational complexity with fewer optimized parameters. In experiments, the Selector-Combiner (SLR) method demonstrates effectiveness across image, NLP, and LLM tasks, outperforming the Score-Combiner (SCR) and validating the rationality of its structural design.

Strengths and weaknesses

Strengths

  1. This paper firstly introduces an ensemble framework in post-hoc selective classification. By learning weights and thresholds to fuse probability predictions, energy, distance, and other multiple confidence scores, it achieves robustly distinguishing between reliable and unreliable samples under distribution shifts. Theoretically, the Oracle inequality is proposed to prove that the ensemble performance is not inferior to the "post-hoc optimal single score". Experiments verify the effectiveness of multi-task methods, and ablation experiments (calibration set size, number of basis selectors, optimization objective) verify the stability of the method. The lightweight design supports fast convergence with small samples.

  2. To address the limitations of traditional selective classification, an integrated framework is proposed that fuses diverse confidence scores. The method is logically rigorous, and theoretical analysis and experimental verification corroborate each other.

  3. AURC-SLR addresses the instability of a single score under distribution shifts through an integrated framework and AURC optimization, improving robustness and reducing risk. It has significant advantages in high-risk fields such as medical diagnosis and risk control, and it’s also scalable, and plug-and-play.

  4. AURC-SLR firstly combines ensemble learning with post hoc SC. It introduces an SLR structure that converts confidence scores into binary selection signals via thresholds, reducing dependence on raw score distributions. Additionally, it develops a SoftRank AURC loss that directly optimizes AURC through pairwise soft ranking, enabling end to end optimization of the risk coverage tradeoff. Rigorous theoretical proofs ensure the innovation and rigor of the method.

Weaknesses

  1. This method relies on the quality of the calibration data and assumes consistency with the deployment distribution, but sampling bias and distribution drift may exist. The size of the calibration set may also affect the weight learning and convergence of the ensemble learning.

  2. The paper uses two ensemble architectures: the Score Combiner (SCR) and the Selector Combiner (SLR). Experimental results show that both have their advantages on different datasets, but the paper does not provide any analysis on scenarios for applying the two methods.

Questions
  1. The paper compares the results of two ensemble methods, SCR and SLR. Both methods have advantages on different datasets, but the authors do not specifically analyze the optimal phenomenon of each method on different datasets or provide further selection criteria. It is suggested that the authors briefly explain and analyze the relationship between SLR and SCR, as well as the selection method and its applicable scope.

  2. When comparing ensemble confidence scores, the authors did not use SoftRank-AURC loss for univariate threshold tuning of the individual confidence scores being compared. Adding a set of comparative experiments could be tried to further verify the advantages of the ensemble methods.

  3. The calibration dataset used for training has the same distribution as the deployment distribution, and the CDF is assumed to be continuous. However, some confidence scores selected in the paper show discrete values, conflicting with the theoretical assumptions. The authors need to further explain this theoretical issue and propose feasible solutions.

Limitations
  1. The SoftRank-AURC loss function is based on pairwise soft comparisons, with a computational complexity of O(N²). As the size of calibration set increases, the training cost rises, thus limiting the direct deployment of this method in large-scale data or dynamic scenarios requiring frequent calibration.

  2. Ensemble frameworks only optimize the selection strategy by combining confidence scores, failing to address issues such as the bias of base classifiers towards specific classes and insufficient feature extraction capabilities. If the base classifiers systematically misclassify samples of a certain class, the ensemble method may amplify the errors rather than correct them.

3.The Oracle inequality proof used in this paper relies on the score regularity assumption (CDF Lipschitz continuity). However, when some base scores (such as KNN distance) become discontinuous due to data sparsity, the applicability of the theoretically guaranteed inequality is affected.

Final justification

I appreciate the authors’ efforts in answering my questions. I keep my positive evaluation and encourage the authors to revise the manuscript if the paper is accepted.

Formatting concerns

The paper fully complies with the NeurIPS 2026 formatting and anonymity guidelines. No major issues requiring correction were identified.

1 comment
Authors · CommentOpenReview ↗

We thank the reviewer for their insightful comments and strong support of the paper. The points on the assumptions behind the calibration data, on the choice between the two ensemble architectures, and on the regularity condition used in the oracle inequality were all well taken.

Weakness 1 — Quality of the calibration data and calibration-set size

  • We agree that the size of the calibration set matters. But our ensemble model is simple and lightweight enough, containing only 2K2K learnable parameters, where KK is the number of base selectors and is typically small—for example, ∼10\sim 10 for the excellent performance reported in the experiments. Thus, training the model only requires very small number of calibration samples, leaving insufficient calibration data very unlikely.
  • We also agree that distribution shifts between the deployment and calibration distributions may impair the ensemble selector. A natural fix to it is to integrate change detection and recalibration, and the very low data requirement also makes periodic recalibration practical. We would like to pursue this online version as future work.

Weakness 2 / Question 1 — Choosing between SCR and SLR

We agree that there is no clear winner between SLR and SCR in our experiments. However, both methods are sufficiently lightweight, so it is relatively easy to perform validation-based model selection in practice.

Question 2 — Threshold tuning for the individual confidence scores

Threshold tuning is not needed: the AURC metric is threshold-free, so these base confidence scores have no learnable parameters. In our ensemble model, the learnable thresholds are for the base selectors, and we do not have a threshold for the final ensemble score either.

Question 3 / Limitation 3 — Discrete scores and the CDF continuity assumption

Thank you for this thoughtful comment!

  • First, we want to clarify first the regularity condition concerns the distribution of the learned ensemble score S(x)S(x), not the base scores.

We have carefully checked our theoretical analysis, trying to clarify and minimize the assumptions.

  • With a rigorous proof, we can show that continuity is not needed for the population AURC and its mathematical characterization we use in the paper.
  • The empirical-to-population generalization analysis of the smooth SoftRank objective does not require CDF continuity either. It relies on the boundedness and complexity measure of the ensemble-score class and on the Lipschitz properties of the smoothing functions.
  • The regularity assumption is used to rule out ties in the scores only when we relate the smoothed population loss to the exact AURC. With ties, these two losses can be different, even if κ→0\kappa \to 0. So, honestly, it is stronger than necessary, and we can directly replace it with a weaker no-ties assumption.
  • To be consistent with this refined theoretical analysis, in practice, one can perform a simple randomized tie-breaking by injecting negligible independent noise to the final scores.

We will clarify all these points in our revision.

Limitation 1 — O(N2)O(N^2) cost of the pairwise loss

  • We totally agree that this O(N2)O(N^2) cost would be expensive if we need to train the ensemble on large-scale calibration sets.
  • But, as we have argued above, our ensemble model is very lightweight and typically requires only small calibration sets in practice.
  • The original AURC loss can actually be computed in O(Nlog⁡N)O(N \log N) time , dominated by a sorting step. We cannot take advantage of quick sorting algorithms in the SoftRank loss due to the smoothing. We have some ideas on how to work with the original AURC loss directly, and we will explore this in future work.

Limitation 2 — Class-specific bias of the base classifier

  • We agree that our current method does not address the potential bias and weak performance of the base classifier itself.
  • Regarding weak performance: the motivation we work on selective classification is exactly to make imperfect classifiers more reliable and deployable. Our method is agnostic to the performance level of the base classifier.
  • Regarding classifier's intrinsic biases: our current AURC metric is defined at the population level, so it does not account for subgroup or class-specific disparities. To mitigate potential selection biases, one could consider learning with subgroup or class-wise AURC instead—in line with the "direct metric optimization" philosophy of the current paper. We will leave this for future work.

We thank the reviewer again for these comments, in particular for the observation about discrete scores, which has forces us to rethink our theoretical analysis and clarify several things ourselves. We hope the responses above address the concerns raised, and we are happy to provide further clarification during the discussion period.

Reviewer infMOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper considers the problem of post-hoc selective classification. In particular, instead of proposing a new method of learning a new score function (rejector) from scratch, the paper instead considers the problem of create ensembles from pre-existing score functions. The proposed approach involves optimizing the aggregated combination of scorers after normalization (either via linear or "selector" linear combination). To learn the parameters of the ensemble, AURC related losses are optimized.

Strengths and weaknesses

Strengths

  1. Combining different confidence scores seems like an intuitive way of improving selective classification.
  2. The scorer dataset construction and ensemble training is sound.
  3. The empirical results are promising.

Weaknesses

  1. It may be worth to add SELE-MLP as a baseline, ie, AURC-MLP but with AURC switched for SELE as its loss function. From what I understand, SELE is a nicer optimization objective so it would be interesting to compare SELE-MLP against the SCR and SLR variants.
  2. Ensembling different confidence scorers only seems to make sense if the base scorers are accurate and diverse. This assumption has not been explored.
  3. Along these lines, the clarity of how the base-scorers are being combined might be interesting to further examine. For instance, in the linear case, do the weights correspond to the individual performance of the base scorers? Are there only a few scorers with high weights? Are some scorers contributing nothing?

Minor:

  • Typo on line 128: "We provide the constants and in Sec. A"
Questions
  1. How important is the proposed score normalization? For instance, would switching the median to a mean cause issues?
  2. How diverse is the set of confidence scorers which are ensembled?
  3. (Repeating Weakness 3) In the linear case, do the weights correspond to the individual performance of the base scorers? Are there only a few scorers with high weights? Are some scorers contributing nothing?
  4. A motivation of the paper is to "allow distribution shift". How robust is the ensembling? Suppose that one of the scorers is poisoned (performs particularly badly for the calibration set). Does the trained ensembles appropriately deal with this?
  5. Inverse to my stated Weakness 2, is diversity required? I am wondering if non-negligible improvements can be possible if the ensemble elements are not diverse (or even just repeats of the same scorer).
Limitations

yes

Final justification

The authors have answered my questions adequately. I think that the additional discussion and analysis regarding the "weighting behavior" of their ensembles would be useful additions in understanding the proposed approach.

Formatting concerns

None

5 comments
Authors · CommentOpenReview ↗

Response to Weakness 1 and Weakness 2 / Question 2 / Question 5

We thank the reviewer for the thoughtful and constructive review. The suggestions on the SELE-MLP baseline, on the role of accuracy and diversity among the base scorers, and on the behavior of the ensemble under a corrupted member were all well taken, and we have run new experiments for each.

Weakness 1 — SELE-MLP as an additional learned baseline

  • We agree that SELE is a nicer loss in theory, in the sense it is a differentiable and convex surrogate with respect to the score for the AURC objective. But, when composed with the nonlinear MLP, the conceptual advantage will not necessarily carry over.
  • As suggested, we ran SELE-MLP on all 15 image and NLP datasets. Our SoftRank-AURC gives better results than SELE on 10/15 datasets (The table below reports every dataset at the largest calibration size, n=1000n=1000).
Dataset SELE-MLP AURC-MLP Δ\Delta
ADE 51.24 (1.39) 51.14 (2.28) −0.2%
AMAZON 12.55 (0.04) 13.01 (0.57) +3.7%
CALTECH 1.35 (0.30) 1.41 (0.29) +4.4%
CIFAR10 2.72 (0.73) 2.82 (0.82) +3.7%
CIFAR10-C 7.77 (0.30) 7.76 (0.47) −0.1%
CIFAR100 25.75 (0.53) 24.54 (0.39) −4.7%
EYEPACS 9.63 (0.28) 9.80 (1.02) +1.8%
IMAGENET 8.40 (0.43) 8.01 (0.61) −4.6%
IMAGENET-O 10.20 (0.57) 9.95 (0.94) −2.5%
IWILDCAM-ID 7.23 (0.19) 7.41 (0.25) +2.5%
IWILDCAM-OOD 8.16 (0.05) 8.15 (0.55) −0.1%
OPENIMAGE-O 16.58 (0.46) 15.73 (1.28) −5.1%
NIHLT 67.42 (2.27) 67.08 (1.53) −0.5%
PCAM 8.96 (2.39) 8.50 (2.22) −5.1%
SST2 9.40 (0.44) 9.28 (0.40) −1.3%

On a related note, Zhou et al. (2024) compared SELE with another smooth approximation to AURC on supervised learning tasks, and also found that SELE performed worse than their proposed surrogate.

  • Zhou, H., Van Landeghem, J., Popordanoska, T., and Blaschko, M. B. A novel characterization of the population area under the risk coverage curve (AURC) and rates of finite sample estimators. arXiv:2410.15361, 2024.

Weakness 2 / Question 2 / Question 5 — Accuracy and diversity of the base scorers

We thank the reviewer for raising this insightful point!

  • Our method does not require any assumptions about the base selectors to operate. The ensemble weights are learned directly with respect to the AURC objective.

But, conceptually, we do need the following very mild assumptions about the accuracy and diversity of the base selectors to obtain non-negligible improvements.

  • The base selectors are reasonably diverse, i.e., providing complementary information. In our experiments, the scores are reasonably diverse, as (1) they are typically different functions of different subsets of {softmax logits, raw logits, or final features}; and (2) they show very different performance levels in our experiments.
  • A nontrivial subset of the selectors are reasonably accurate. Non-accurate selectors, e.g., random selectors in the extreme case, will receive low to zero weights.

We will clarify this in our revision.

Authors · CommentOpenReview ↗

Response to Weakness 3 / Question 3

Weakness 3 / Question 3 — What the learned weights look like in practice

Thanks for the insightful question! We agree that examining the learned weights provides useful insight into how the base scorers are combined. During the brief rebuttal period, we have performed additional analysis about this. The following table reports the normalized weight assigned to each base scorer across the 15 image and NLP datasets, together with the concentration of the learned weights, measured by the share held by the three largest weights (top-3).

Ensemble Weight Distribution

Variant Data RLmaxRL_{max} SRmaxSR_{max} SRdocSR_{doc} SRentSR_{ent} ViMViM SIRCSIRC KNNKNN EnergyEnergy RLconf-MRL_{\text{conf-M}} RLgeo-MRL_{\text{geo-M}} top-3
AURC-SCR ADE 0.2 0.1 0.2 0.4 0.0 45.9 52.9 0.0 0.1 0.1 99.3
AMZ 5.7 13.1 12.3 35.8 7.7 19.5 2.6 2.0 1.3 0.0 86.4
CAL 16.1 2.1 23.6 35.4 1.5 3.1 0.1 13.8 2.2 2.1 77.4
C10 0.6 4.8 0.8 0.3 11.7 0.3 34.9 0.4 33.5 12.8 88.2
C1C 3.1 0.3 0.0 0.1 0.2 0.1 56.4 3.4 31.7 4.7 95.7
C100 0.0 0.4 0.3 0.7 0.2 0.1 85.0 0.0 6.5 6.7 98.7
EYE 0.0 21.3 21.5 3.3 12.4 15.7 7.6 0.0 12.3 5.8 75.7
IMN 7.2 6.0 3.6 2.6 0.2 0.1 2.9 3.2 36.7 37.4 90.3
INO 13.1 4.6 3.3 0.5 0.0 0.1 1.8 13.6 32.0 31.0 81.6
WID 0.2 16.0 11.5 6.8 0.0 8.9 19.7 0.2 18.4 18.4 65.7
WOD 0.1 16.0 12.7 11.2 3.3 1.6 33.2 0.1 11.0 11.0 72.9
OIO 24.9 6.3 9.2 4.3 1.0 1.1 1.6 16.6 14.8 20.2 64.5
NIH 4.5 0.0 1.1 4.6 0.4 2.1 49.6 32.4 1.0 4.4 93.5
PCM 0.0 6.1 6.0 4.7 21.9 9.4 18.6 0.0 16.6 16.6 74.5
SST 11.9 2.0 2.1 2.6 15.3 13.4 0.7 6.7 22.6 22.6 69.3
#off 7 4 4 5 8 5 2 7 2 2 datasets with <1% share (of 15)
AURC-SLR ADE 7.6 3.3 4.1 1.7 0.0 36.6 34.6 6.4 3.2 2.4 80.8
AMZ 4.9 13.7 14.8 36.4 3.9 15.2 4.7 2.6 3.3 0.6 75.4
CAL 12.3 12.1 11.4 5.6 2.2 10.5 0.4 16.4 14.6 14.6 58.7
C10 2.9 8.7 0.4 1.4 20.5 1.8 23.0 3.1 20.3 17.8 77.5
C1C 13.0 4.4 4.1 0.3 0.0 2.7 16.9 21.9 26.4 10.3 82.9
C100 1.4 3.0 3.0 3.6 3.2 0.1 52.0 6.6 13.2 13.9 87.1
EYE 0.0 20.7 19.5 0.7 14.2 14.1 7.0 0.4 15.9 7.3 80.2
IMN 6.2 5.3 3.5 2.9 0.1 0.3 3.1 4.1 36.6 38.0 88.5
INO 12.8 13.0 10.1 1.7 2.2 2.3 3.3 13.3 19.9 21.4 58.6
WID 0.2 29.3 6.3 4.0 0.0 7.7 20.2 0.0 16.1 16.1 72.8
WOD 1.0 14.1 13.7 12.8 1.5 12.5 17.1 1.9 13.0 12.3 45.4
OIO 13.0 12.3 12.7 12.0 5.4 9.5 1.2 12.7 10.5 10.7 39.4
NIH 2.5 0.0 1.4 5.0 3.2 0.0 57.7 25.6 0.0 4.7 93.6
PCM 9.5 4.6 4.8 5.2 42.5 9.9 3.0 3.4 8.6 8.6 68.4
SST 20.6 6.8 7.5 3.2 26.8 9.4 9.1 6.6 5.0 5.0 73.3
#off 3 1 1 2 4 3 1 2 1 1 datasets with <1% share (of 15)

Do the learned weights correspond to the individual performance of the base scorers?

  • We see a trend of assigning larger weights to better-performing selectors on multiple datasets. For example, on ADE, KNN is the strongest individual scorer and receives the largest weight. The weight of the best individual scorer never falls below 1%.
  • However, the weights are not determined by performance alone. For example, on CALTECH under AURC-SLR, Energy is 2.4 worse than SR<sub>ent</sub>. Yet Energy receives the largest weight in that combination, while SR<sub>ent</sub> receives only 5.6%. The final ensemble performance is still better than any individual scorer, suggesting the ensemble is exploiting complementary information from the base scorers.

Are only a few scorers assigned high weights / unused

  • In many datasets, the weights are concentrated on a relatively small subset of scorers. KNN, SIRC, RL<sub>c-M</sub>, and RL<sub>g-M</sub> are frequently among the scorers receiving the largest weights. But the selectors with the large weights may vary across datasets.
  • There is no single base selector that is assigned high weights for all datasets. Similarly, no single scorer is consistently inactive across all datasets and objectives, suggesting that the usefulness of an individual scorer depends on the dataset and optimization criterion.
Authors · CommentOpenReview ↗

Response to Question 1 and Question 4

Question 1 — Importance of the median/MAD normalization

Why normalization is needed: Since these scorers may assign confidence values of different scales and distributions, we need to normalize them to a common scale and similar distributions before combining them.

Why we use MAD normalization: To normalize each scorer, it is tempting to consider the standard zero-mean-unit-variance normalization. But both the mean and the variance are sensitive to outlying probability masses, and they could be ill-defined for certain heavy-tailed distributions. To verify this, we use two statistical quantities to characterize the distributions of each score averaged over the 15 datasets used in our experiments:

  • Skewness, which measures the mean shift relative to the median, i.e., asymmetry in the distribution. The larger the absolute value of skewness, the more asymmetric the distribution;
  • Kurtosis, which measures the heaviness of the tails. Kurtosis ≥3\ge 3 means heavier tails than a Gaussian distribution, and the larger the kurtosis, the heavier the tails.
Selector SRmaxSR_{max} SRmaxSR_{max} SRentSR_{ent} KNNKNN SIRCSIRC RLmaxRL_{max} EnergyEnergy RLconf-MRL_{\text{conf-M}} RLgeo-MRL_{\text{geo-M}} ViMViM
skewness −17.74 −6.20 −7.30 −1.55 −1.31 −0.33 −0.23 −1.20 −1.20 −0.34
kurtosis 386.3 47.3 73.7 6.3 4.6 2.7 2.4 4.2 4.2 2.9

The results summarized in the above table clearly indicate that the majority of score distributions are substantially skewed and heavy-tailed, and hence cannot be well-approximated by a Gaussian distribution. Thus, we use a robust alternative based on the median and the median absolute deviation (MAD).

Question 4 — Robustness of the ensemble to a poisoned base scorer

  • In the paper, we always assume the calibration and deployment distributions are the same. The "distribution shifts" we talk of in the introduction refer to the shift of deployment distribution from the classifier's training distribution, not from the calibration distribution.
  • If the reviewer's question is about our ensemble method's behavior on bad-behaved base scorers: due to our direct global optimization of the AURC objective, the ensemble will assign low weights to scorers that perform poorly on the calibration set, per our response to Weakness 3/Question 3 above.
  • If the reviewer's asking how deployment-time corrupted scorers can affect trained ensembles during deployment: our current setting does not allow for this. But it is clear in such cases that the ensemble's performance will depend on the corrupted scorers ensemble weights and the corruption levels—if a top contributing scorer is corrupted, the ensemble's performance may collapse. A systematic fix to this kind of distribution shift or even drift over time is frequent recalibrations of the ensemble, which is outside the scope of this paper.

Minor — Typo on line 128

We will correct the typo.


We thank the reviewer again for these suggestions. The SELE-MLP baseline, the analysis of the learned weights, and the poisoned-scorer study all originated from this review and will be included in the revision. We hope the responses above address the concerns raised, and we are happy to provide further clarification during the discussion period.

Reviewer jj1KOpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes a post-hoc method for selective classification based on ensemble learning to optimize AURC metric. The key idea is to learn an ensemble of predictor whether the model will predict correctly or not. Theoretical analysis is conducted to justify the usefulness of the ensemble method. Extensive experiments show the effectiveness of ensemble approach in selective classification in this post-hoc setting.

Strengths and weaknesses

Strengths

  1. Extensive experimental results to show the effectiveness of the proposed method.
  2. The proposed method looks simple and effective to use in the real world.
  3. The proposed method seems novel and is also equipped with a theoretical analysis.

Weaknesses

  1. It seems the proposed method also has several hyperparameters / constants
  2. For experiments, to understand baseline it is required to read appendix section (B).
  3. Theoretical analysis might not really tell ensemble is as competitive as the best one. As there are some big-O term that might not be decreased even with infinite data (see more in question section)?
Questions
  1. In theoretical analysis, it is claim that the result implies SoftRANK-AURC learning is at least competitive with the best selector. I think this statement could be overclaim as the inequality in 3.13 may have the third term that will not reduce, no matter how much data we have. Is my understanding correct?
  2. In total, how many hyperparameters in this algorithm? How sensitive are they to the proposed method?
  3. What is K in line 144 that mention to be O(K^2)
  4. Can we say the current experiment setup is fair to all methods?
  5. I couldn't fully understand the part in Line 142-145: how do we learn K binary scorer to predict the score? How big is this model to achieve each s_t, how many parameters to they have? Do they not scale with the neural network size but only number of ensemble O(T)?

Minor comment

  1. Line 12: SELE abbreviation should be discussed
  2. In Algorithm 2, should we refer to Sec. A or 3.2, 3.3?
  3. What is MAD in 3.2? If explained the word, maybe it is useful to pick up the intuition of the equation quickly.
Limitations

Yes

Final justification

After the rebuttal, my evaluation of the paper remains positive. If the paper is accepted, I encourage the authors to revise the manuscript to improve the clarity of the writing and update the discussion of the theoretical analysis.

Formatting concerns

None

3 comments
Authors · CommentOpenReview ↗

We thank the reviewer for their insightful comments!

Weakness 1 / Question 2 — Number and sensitivity of hyperparameters

The SCR model itself does not have any hyperparameters; the SLR model contains two hyperparameters, σ\sigma and β\beta, which control the temperatures for the sigmoid and the hyperbolic tangent smoothing, respectively. Additional hyperparameters are in the optimizers, including either LBGFS and ADAM, but we use their default hyperparameter settings with good empirical performance.

We finetune the critical hyperparameters, σ\sigma and β\beta, with respect to the validation set with negligible computational overheads, due to the relatively tiny scale of our experiments. From our experience, we do not find any hyparameters that are particularly sensitive to the performance of our method.

Weakness 2 — Description of the baselines in the appendix

Thanks for pointing this out! In our revision, we will concisely summarize our baseline, selection criterion, and justification of them in a table in the main text for better readability.

Weakness 3 / Question 1 — Scope of the oracle guarantee and the non-vanishing remainder

Thank you for this insightful comment!

  • Your understanding is correct: in the current form of Eq.~(3.13), if εα\varepsilon_\alpha and κ\kappa are treated as constants, the last term does not vanish as N→∞N \to \infty. Thus, our phrasing ``at least competitive with the best selector'' is not accurate, and we will revise it.
  • εα\varepsilon_\alpha is introduced below Eq.~(3.9) solely as a numerical safeguard to avoid evaluating the logarithm at zero. Following the convention of statistical learning theory that typically ignores numerical tolerances, we can actually remove it from the final bound.
  • For κ\kappa, the situation is more subtle. Our current analysis might be suboptimal and its form might be improvable, but we tend to think it might be unremovable due to the similar smoothing role it plays to the margin parameter in classic margin-based generalization bounds (e.g., for SVMs and boosting). In these classic results, the margin parameter is also a constant that does not vanish as N→∞N \to \infty; see, e.g., Sec. 5.4 of the following learning theory textbook:

    Mohri, M., Rostamizadeh, A., & Talwalkar, A. (2018). Foundations of machine learning. MIT press.

In any case, we will try our best to tighten up the analysis and precisely state the implications of our theoretical results in the revision.

Question 3 — Meaning of KK

KK is the number of classes, as described in the basic SC setup in Section 2.

Question 4 — Fairness of the experimental setup

  • We believe so. All learned methods use the same fixed classifier outputs, calibration/validation/test splits, validation budget, and random seeds. The hand-crafted confidence scores require no supervised fitting and are included as calibration-free baselines. AURC-MLP and the newly added SELE-MLP use the same labeled calibration data as our ensembles, providing learned black-box comparisons.
  • We suspect this concern probably arises because we did not provide sufficient details about baseline methods in the main text; we will provide concise summaries of these in our revision.

We are happy to clarify further if the reviewer has any specific remaining concerns.

Question 5 — Parameter count of the ensemble and of the MLP baseline

We are sorry for not providing sufficient details about the argument, that leads to the confusion!

  • By "setting up a simple multi-layer perceptron143(MLP) to learn a score function", we mean an alternative to our ensemble method: take all the KK logits as input to a shallow MLP and output a single confidence score. So, if we have O(K)O(K) hidden nodes in the MLP, we have a total of O(K2)O(K^2) weights in the MLP.
  • In contrast, learnable parameters in our ensemble method are the weights and thresholds for TT base scorers, resulting in a total of 2T2T parameters, i.e., O(T)O(T).

We will detail this in our revision.

Minor concerns — SELE abbreviation, Algorithm 2 cross-reference, MAD

These are all good points. We will define the SELE abbreviation at first use, correct the cross-reference in Algorithm 2, and spell out the median absolute deviation (MAD) together with a sentence on the intuition behind the normalization.


We thank the reviewer again for these comments, which have improved both the precision of our theoretical claim and the clarity of the experimental section. We hope the responses above address the concerns raised, and we are happy to provide further clarification during the discussion period.

Reviewer jj1K · CommentOpenReview ↗

Thank you for the reply

I appreciate the authors’ efforts in addressing my concerns in the rebuttal. At this point, my evaluation of the paper remains positive. If the paper is accepted, I encourage the authors to revise the manuscript to improve the clarity of the writing and update the discussion of the theoretical analysis.

Authors · CommentOpenReview ↗

We thank the reviewer for the positive evaluation of our paper and for the constructive suggestions. We believe that the discussions during the rebuttal period have helped strengthen our work. If the paper is accepted, we will carefully revise the manuscript as suggested.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…