Extending Pretrained 10-Second ECG Foundation Models to Longer Horizons
Wei Tang, Jinpei Han, Kangning Cui, Mattia Carletti, Fredrik K. Gustafsson, Shreyank N Gowda, Patitapaban Palo, Anshul Thakur, Lei Clifton, Jean-michel Morel, Raymond H. Chan, David A. Clifton, Xiao Gu
NeurIPS 2026
Abstract. Electrocardiogram (ECG) foundation models pretrained on typical diagnostic 10-second ECG segments, have demonstrated strong transferability across a range of clinical applications. However, many real-world applications produce recordings that are typically longer, and are varied in duration during inference time. These 10-second models have no built-in way to combine information across time. Extending them to longer horizons introduces two challenges: structural incompatibilities arising from input-length disparities, and semantic challenges that limit meaningful temporal aggregation. We propose a parameter-efficient framework that extends pretrained ECG foundation models to longer and variable-length ECGs without retraining the backbone. Guided by a frozen pretrained 10-second model, we introduce a lightweight plug-in module that extends the model in two complementary ways: (i) structurally compatible long-sequence processing and (ii) semantically informed temporal modeling. Experiments on multiple long-horizon ECG tasks, datasets, and foundation model backbones demonstrate that our method enables robust long-horizon extension from pretrained snapshot models, consistently outperforming sliding-window and pooling-based baselines with strong parameter efficiency.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:48 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper Needs Clarification during Response Period. It proposes a parameter-efficient framework for adapting frozen 10-second ECG foundation models to 1–5 minute recordings using hierarchical positional encoding, soft prompts, locality-aware contrastive learning, and dynamics-aware consistency. Reviewers 51AV and UWoS find the problem practical, the evaluation comprehensive, and the gains consistent across several ECG backbones, tasks, and recording durations.
The main concern is whether the evaluated 180-second setting establishes a clinically meaningful long-horizon problem. Reviewer 51AV notes that VTaC performance saturates beyond 60 seconds, while Reviewer UWoS cautions that 1–5 minutes is still far from 24–48 hour Holter monitoring. Reviewer HjLT also asks for wearable single-lead ECG evaluation, where longer monitoring is more natural than for standard 12-lead ECGs.
The empirical case would also benefit from stronger controls. The improvements are moderate, with no seed-level variance, CIs, or significance tests. Reviewer HjLT questions whether the full fine-tuning baseline is implemented fairly and notes that stronger ECG FMs, such as ECGFounder, D-BETA, and MELP, are absent. The effects of soft prompts and global positional encoding are not separated, while the gains appear to come mainly from the locality-aware loss.
Finally, the claimed variable-length and parameter-efficient properties are not fully evaluated. The method uses fixed non-overlapping 10-second segments and a finite learned positional table, with no tests on unseen lengths, overlapping windows, or segment-boundary events. FLOPs, GPU memory, training time, inference latency, and parameter overhead are also missing.
The rebuttal should prioritize addressing the following concerns raised by reviewers:
- Results at 30, 60, 120, and 180 seconds on all tasks, compared with at least one snapshot and one fine-tuning baseline.
- Report Mean +- SD and paired tests or CIs for the main comparisons.
- Full details and verification of the fine-tuning baselines, especially how 10-second FMs are adapted and aggregated at test time.
- Separate ablations for soft prompts, global positional encoding, locality-aware loss, and dynamics-aware loss.
- Tests on unseen sequence lengths and overlapping windows, including events crossing 10-second segment boundaries.
- Parameter count, FLOPs, GPU memory, training time, and inference latency as sequence length increases.
- A wearable single-lead ECG experiment or a narrower framing of the clinical long-horizon claims.
Final justification
The author response addressed the main concerns from the initial reviews. Reviewer HjLT increased the rating after the added experiments on architecture/teacher generality, the full fine-tuning protocol, statistical uncertainty, and additional ablations. Reviewers also found that concerns about metric reporting, computational cost, and uncertainty quantification were substantially addressed.
The main remaining limitation is that the claimed parameter efficiency is not supported by a direct computation-overhead analysis. Overall, however, the response resolves the salient technical and evaluation concerns sufficiently.
Read meta-review
Meta-review
This paper Needs Clarification during Response Period. It proposes a parameter-efficient framework for adapting frozen 10-second ECG foundation models to 1–5 minute recordings using hierarchical positional encoding, soft prompts, locality-aware contrastive learning, and dynamics-aware consistency. Reviewers 51AV and UWoS find the problem practical, the evaluation comprehensive, and the gains consistent across several ECG backbones, tasks, and recording durations.
The main concern is whether the evaluated 180-second setting establishes a clinically meaningful long-horizon problem. Reviewer 51AV notes that VTaC performance saturates beyond 60 seconds, while Reviewer UWoS cautions that 1–5 minutes is still far from 24–48 hour Holter monitoring. Reviewer HjLT also asks for wearable single-lead ECG evaluation, where longer monitoring is more natural than for standard 12-lead ECGs.
The empirical case would also benefit from stronger controls. The improvements are moderate, with no seed-level variance, CIs, or significance tests. Reviewer HjLT questions whether the full fine-tuning baseline is implemented fairly and notes that stronger ECG FMs, such as ECGFounder, D-BETA, and MELP, are absent. The effects of soft prompts and global positional encoding are not separated, while the gains appear to come mainly from the locality-aware loss.
Finally, the claimed variable-length and parameter-efficient properties are not fully evaluated. The method uses fixed non-overlapping 10-second segments and a finite learned positional table, with no tests on unseen lengths, overlapping windows, or segment-boundary events. FLOPs, GPU memory, training time, inference latency, and parameter overhead are also missing.
The rebuttal should prioritize addressing the following concerns raised by reviewers:
- Results at 30, 60, 120, and 180 seconds on all tasks, compared with at least one snapshot and one fine-tuning baseline.
- Report Mean +- SD and paired tests or CIs for the main comparisons.
- Full details and verification of the fine-tuning baselines, especially how 10-second FMs are adapted and aggregated at test time.
- Separate ablations for soft prompts, global positional encoding, locality-aware loss, and dynamics-aware loss.
- Tests on unseen sequence lengths and overlapping windows, including events crossing 10-second segment boundaries.
- Parameter count, FLOPs, GPU memory, training time, and inference latency as sequence length increases.
- A wearable single-lead ECG experiment or a narrower framing of the clinical long-horizon claims.
Final justification
The author response addressed the main concerns from the initial reviews. Reviewer HjLT increased the rating after the added experiments on architecture/teacher generality, the full fine-tuning protocol, statistical uncertainty, and additional ablations. Reviewers also found that concerns about metric reporting, computational cost, and uncertainty quantification were substantially addressed.
The main remaining limitation is that the claimed parameter efficiency is not supported by a direct computation-overhead analysis. Overall, however, the response resolves the salient technical and evaluation concerns sufficiently.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 2/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes a parameter-efficient framework to adapt frozen 10s ECG foundation models to longer and variable-length recordings, combining a hierarchical positional encoding scheme, soft prompt tuning, a locality-aware soft contrastive objective, and a dynamics-aware consistency loss guided by teacher-derived affinity.
Strengths and weaknesses
Strengths
- The motivation for extending 10-second ECG foundation models to long-horizon settings is clinically important.
Weaknesses
-
Computational overhead is not reported
-
Moderate performance improvement
Questions
-
The paper demonstrates that long-horizon adaptation is technically feasible, but does not fully establish that the evaluated settings correspond to the scenarios where long-horizon ECG modeling is clinically necessary. Please discuss downstream tasks that need long term monitoring. Also, the paper also benefit from testing wearable single lead ECG FMs (support long-term monitoring essensially more), instead of just 12-lead ECG FM (12 lead ECG with only 10s is very common and standard already in clinical setting, that doctors read daily).
-
The proposed framework is evaluated exclusively on transformer-based ECG foundation models, and several of its key components, including hierarchical positional encoding and prompt tuning, are inherently tied to transformer architectures. Furthemore, the effectiveness of the semantic extension appears dependent on the quality of the teacher backbone, limiting the generality of the proposed approach. The authors should evaluate and discuss it.
-
It remains unclear how experiments with finetuning baselines are conducted. It would be not persuadable if: the work finetunes 10s-ECG FMs, using 180s windows. The right thing to do I think is: finetuning 10s-ECG FMs on 10s windows, then, test those finetuned models with 180s by spliting to 10s and do some aggregation/ensemble for final results. (I really question this since I am quite surprised when the results of Full Fine-tuning is quite low in Table 1).
Limitations
-
Computational overhead, parameter counts, FLOPs, GPU memory usage, training time, or inference latency,… are not reported despite repeated claims of parameter efficiency.
-
Several reported improvements are relatively modest, yet no seed-level variance estimates or statistical significance analyses are provided. Also, the gains may be even smaller when testing stronger ECG FMs such as ECGFounder, D-BETA, MELP.
-
The relationship between the proposed consistency objective and existing stop-gradient representation learning methods is not sufficiently discussed.
-
The work relies on non-overlapping 10-second segmentation. Since clinically important events may occur near segment boundaries, the impact of stride choice deserves discussion.
Final justification
The additional experiment on (1) Generality across Architectures and Teacher Backbones, (2) Full fine-tuning protocol, and (3) Statistical uncertainty resolve my previous concerns. However, the claimed parameter efficiency is not backed up with computation overhead measurement. Therefore I increased the rating from borderline reject to borderline accept.
Formatting concerns
No
7 comments
Q2: Generality across Architectures and Teacher Backbones
Most publicly available ECG foundation models that support single-lead evaluation are pretrained on 10-second recordings, which is precisely where they fall short in the longer-horizon scenarios considered here. How this limitation manifests, however, depends on the backbone architecture. Transformer-based models do not necessarily need any adaptation for the lead dimension and can work directly on single-lead input, but their positional embeddings are still tied to the 10-second horizon, such as CSFM and ECG-JEPA. Convolutional-based models are different: the lead structure is baked into the input channels, so a model precisely trained on single-lead is required. Although a fully convolutional model can directly accept longer temporal inputs without positional-embedding extension, it commonly obtains the final representation through global average pooling over the temporal feature map. This preserves locally extracted patterns but does not explicitly model the ordering and interactions among distant ECG segments.
This distinction also explains why Transformers have become increasingly common in ECG foundation models: token-level attention provides an explicit mechanism for capturing dependencies and interactions across temporal segments, while also supporting flexible adaptation to downstream tasks. To provide a convolutional comparison, we additionally evaluate CLEF [1], a publicly available single-lead ResNeXt1D foundation model, against CSFM-Base under the same 180-second linear-probing protocol.
| Architecture | Backbone | VTaC ROC-AUC [95% CI] | MC-MED ED ROC-AUC [95% CI] |
|---|---|---|---|
| Convolutional | CLEF | 72.76 [65.13, 81.82] | 64.86 [60.47, 68.42] |
| Transformer | CSFM-Base | 74.89 [65.34, 83.06] | 70.44 [67.80, 72.77] |
We also agree that semantic extension depends on the quality of the teacher representation. This dependence is already examined in Table 2: at 180 seconds, MERL self-guidance achieves 82.60 AUC on VTaC, while guidance from CSFM-Tiny, CSFM-Base, and ECG-JEPA improves it to 85.19, 86.07, and 85.78, respectively. Importantly, this indicates that the performance of a fine-tuned model is related to the quality of its base model, which is natural, but a weaker student can benefit from a stronger external teacher. We further add the performance of CSFM-tiny guided by a stronger CSFM-Base.
| Guidance | 10s | 30s | 60s | 120s | 180s |
|---|---|---|---|---|---|
| Self-guided | 84.10 | 88.29 | 89.01 | 89.76 | 89.50 |
| CSFM-Base guided | 85.38 | 89.02 | 89.50 | 89.85 | 90.22 |
We will make this analysis more prominent and explicit in the final version.
References.
[1] Shu et al., “CLEF: Clinically-Guided Contrastive Learning for Electrocardiogram Foundation Models,” arXiv 2025.
Q3: Full fine-tuning protocol
We thank the reviewer for identifying an ambiguity in the description of the full fine-tuning baseline. In the submitted experiments, Full Fine-tuning directly adapts the pretrained model on 180-second recordings: the pretrained positional embeddings are extended through interpolation, and all model parameters are updated. It is then evaluated at different input durations. This baseline tests whether a short-horizon foundation model can be converted into a long-context model through conventional end-to-end fine-tuning.
The reviewer's proposed protocol addresses a different and complementary strategy: fine-tuning the backbone on 10-second windows, independently predicting each window of a long recording, and aggregating the window-level predictions. We agree that this is an informative control and denote it as 10-second fine-tuning + logit pooling. We add this baseline using the same patient-level splits and preprocessing on VTaC. Full results will be release in the final version.
| Backbone | Protocol | VTaC Mean [95% CI] |
|---|---|---|
| CSFM-Tiny | 10 s Fine-tuning + Logit Pooling | 70.91 [64.44, 77.61] |
| CSFM-Tiny | Full Fine-tuning | 81.31 [75.36, 86.93] |
| CSFM-Tiny | Frozen backbone + Logit Pooling | 70.24 [55.48, 75.09] |
| CSFM-Tiny | Ours | 87.58 [82.82, 91.37] |
| CSFM-Base | 10 s Fine-tuning + Logit Pooling | 74.22 [65.70, 78.97] |
| CSFM-Base | Full Fine-tuning | 82.66 [75.11, 89.63] |
| CSFM-Base | Frozen backbone + Logit Pooling | 73.92 [61.48, 79.68] |
| CSFM-Base | Ours | 91.95 [88.08, 95.53] |
| ECG-JEPA | 10 s Fine-tuning + Logit Pooling | 77.91 [71.83, 83.42] |
| ECG-JEPA | Full Fine-tuning | 88.68 [84.05, 92.79] |
| ECG-JEPA | Frozen backbone + Logit Pooling | 74.12 [64.07, 78.10] |
| ECG-JEPA | Ours | 90.83 [86.21, 95.03] |
| MERL | 10 s Fine-tuning + Logit Pooling | 75.46 [69.63, 81.61] |
| MERL | Full Fine-tuning | 87.46 [82.24, 92.23] |
| MERL | Frozen backbone + Logit Pooling | 71.39 [67.21, 72.32] |
| MERL | Ours | 81.23 [77.79, 87.74] |
All entries above correspond to the 180-second evaluation. On VTaC, fine-tuning the 10-second model before logit pooling consistently improves over frozen logit pooling, but remains below direct 180-second fine-tuning across all four backbones.
L1: Computational overhead and parameter efficiency
This is a very helpful point. Our intended claim is specifically parameter-efficient adaptation, rather than faster wall-clock training. We will revise the manuscript accordingly to make this distinction more clear.
Appendix B.5 already reports the trainable parameter counts of our method and full fine-tuning across all four backbones. Importantly, our counts include every newly introduced trainable component: the soft prompts, global positional embeddings, projection heads, and classifier. We will make this analysis more prominent in the main text.
To make the practical storage trade-off clearer, we additionally report the cumulative parameters required for four downstream tasks, normalized by the size of one CSFM-Base backbone. “Scope” indicates where tuning occurs, and “Extra modules” indicates modules beyond the pretrained backbone and standard task head.
| CSFM-Base (157.39M) | Total params | Scope: Input | Scope: Backbone | Scope: Task head | Extra modules | |
|---|---|---|---|---|---|---|
| Total # of tasks | 4 | |||||
| (a) | Full Fine-tuning | 4.00× | ✓ | ✓ | ||
| (b) | Linear Probing | 1.00× | ✓ | |||
| Partial Tuning | 1.21× | ✓ | ✓ | |||
| Bias Tuning | 1.01× | ✓ | ✓ | |||
| (c) | Adapter | 1.06× | ✓ | ✓ | ✓ | |
| VPT | 1.09× | ✓ | ✓ | |||
| (ours) | Ours | 1.11× | ✓ | ✓ | ✓ |
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper investigates how pretrained ECG foundation models, originally trained on short 10-second segments, can be extended to longer ECG recordings using a hierarchical architecture. The proposed approach combines, local positional encoding from the pretrained backbone, a learnable global segment-level positional encoding, and soft prompt tuning. In addition to the classification objective, the model is trained with auxiliary objectives, including a soft contrastive loss in a teacher–student framework to preserve representations learned on 10-second segments, and a similarity-based objective intended to capture longer-range temporal dynamics across segments. The method is evaluated across multiple pretrained backbones, different downstream tasks, and varying recording durations, and is compared against several aggregation and adaptation strategies. Overall, the paper addresses a relevant problem of adapting short-context ECG foundation models to longer clinical recordings.
Strengths and weaknesses
Strengths
- The idea of extending pretrained 10-second ECG foundation models to longer temporal horizons is practical and relevant, especially given the availability of such pretrained models.
- The use of multiple pretrained backbones (e.g., CSFM, MERL, ECG-JEPA) strengthens the empirical validity and suggests the method is not tied to a single architecture.
- The evaluation is comprehensive, including multiple recording durations, downstream tasks and adaptation strategies
- The hierarchical design (local + global positional encoding) is a reasonable way to introduce coarse-grained temporal structure into pretrained short-window models.
Weaknesses
- The notion of "long recordings" is limited to 1–5 minutes, which is still far from true long-term ECG monitoring (e.g., Holter recordings over 24-48 hours). As such, claims regarding "long-term" learning or modeling should be avoided. Long term monitoring usually involves event-driven predictions rather than single-label classification.
- Computational constraints appear to have limited experimental rigor (e.g., absence of statistical significance testing or confidence intervals), which weakens the strength of the reported comparisons.
- While the method claims to support variable-length inputs, it is fundamentally built on fixed 10-second segmentation with its learned finite embedding table ("global positional encoding"), and generalization to unseen sequence lengths (e.g., longer segment indices, overlapping windows, or even <10s cases) is not evaluated.
- The use of AUC as the only evaluation metric limits insight into clinically relevant performance, particularly under class imbalance where sensitivity, specificity, and PR-AUC would be more informative.
Questions
- Why did computational complexity prevent standard statistical evaluation (e.g., confidence intervals/bootstrapping or cross-validation)?
- Was any ablation performed to disentangle the effects of soft prompts vs global positional encoding or their interaction? If not, how should their individual contributions be interpreted?
Limitations
- No evaluation of computational cost (e.g., training and inference time, scaling behavior with sequence length, or parameter overhead introduced by prompts and global positional encodings), which limits understanding of efficiency and scalability.
- Limited discussion of variable-length sequence handling. The method appears not to explicitly address this, and a brief discussion or positioning as future work would improve clarity.
- No statistical significance analysis or cross-validation
Final justification
The authors addressed my concerns about metric reporting, computational cost, uncertainty quantification and provided aditional ablations.
Formatting concerns
Nothing to report
5 comments
We appreciate the reviewer's important comments. We agree that the scope of our work, statistical evaluation, and computational claims should be stated more precisely. We address each concern below.
W1: Scope of "long recordings" and long-term monitoring
We agree that recordings of several minutes should not be described as long-term ECG monitoring in the clinical sense. Our experiments establish extension from a 10-second pretraining horizon to longer-scale inputs, rather than modeling of days of recordings such as Holter. Although the title intentionally uses "Longer Horizons," several occurrences of "long-term" or "long recordings" in the manuscript may overstate the evaluated scope. We will replace them with "longer-horizon," "extended-context," where appropriate.
This is a very good point, and we thank the reviewer for this insightful suggestion. We will make this clear in our final version. Our contribution is a method for adapting a pretrained 10-second foundation model to a longer duration and applying the adapted model to different durations within that range. It does not address unrestricted sequence-length extrapolation. Very long monitoring introduces distinct challenges, which might need additional non-trivial efforts , such as intensive computational cost. We mentioned this briefly in the original version (Line 353-358, Conclusion section), and we will explicitly state this boundary and position adaptation to very long recordings as an important direction for future work.
W2 & Q1 & L3: Confidence intervals, statistical evaluation, and cross-validation
We agree that the uncertainty estimates are important for the comparisons. We are therefore adding patient-level 95% bootstrap confidence intervals for the principal comparisons. In each resample, test-set patients are sampled with replacement, with all recordings and segments from the same patient kept together. The confidence interval is defined by the 2.5th and 97.5th percentiles of the resulting metric estimates. Full results will be released in our final paper.
| Backbone | Method | VTaC AUC [95% CI] | VTaC ΔAUC | MC-MED ED AUC [95% CI] | MC-MED ED ΔAUC |
|---|---|---|---|---|---|
| CSFM-Tiny | Linear Probing | 71.54 [57.14, 77.66] | +16.04 | 69.72 [67.23, 72.20] | +2.28 |
| CSFM-Tiny | Full Fine-tuning | 81.31 [75.36, 86.93] | +6.27 | 70.09 [68.59, 73.71] | +1.91 |
| CSFM-Tiny | VPT | 85.69 [78.78, 90.59] | +1.89 | 69.57 [67.11, 71.86] | +2.43 |
| CSFM-Tiny | Logit Pooling | 70.24 [55.48, 75.09] | +17.34 | 70.17 [66.19, 72.66] | +1.83 |
| CSFM-Tiny | Ours | 87.58 [82.82, 91.37] | — | 72.00 [68.74, 73.15] | — |
| CSFM-Base | Linear Probing | 74.89 [65.34, 83.06] | +17.06 | 70.44 [67.80, 72.77] | +2.35 |
| CSFM-Base | Full Fine-tuning | 82.66 [75.11, 89.63] | +9.29 | 70.30 [69.02, 74.80] | +2.49 |
| CSFM-Base | VPT | 89.83 [85.13, 94.46] | +2.12 | 71.59 [69.95, 74.74] | +1.20 |
| CSFM-Base | Logit Pooling | 73.92 [61.48, 79.68] | +18.03 | 71.22 [70.06, 73.43] | +1.57 |
| CSFM-Base | Ours | 91.95 [88.08, 95.53] | — | 72.79 [70.49, 75.42] | — |
| ECG-JEPA | Linear Probing | 77.21 [70.71, 83.32] | +13.62 | 70.85 [68.34, 73.32] | +2.20 |
| ECG-JEPA | Full Fine-tuning | 88.68 [84.05, 92.79] | +2.15 | 68.31 [65.57, 71.38] | +4.74 |
| ECG-JEPA | VPT | 89.39 [85.08, 95.18] | +1.44 | 72.11 [66.81, 73.50] | +0.94 |
| ECG-JEPA | Logit Pooling | 74.12 [64.07, 78.10] | +16.71 | 68.91 [65.15, 72.79] | +4.14 |
| ECG-JEPA | Ours | 90.83 [86.21, 95.03] | — | 73.05 [67.32, 74.47] | — |
| MERL | Linear Probing | 72.97 [69.57, 81.26] | +8.26 | 68.05 [65.62, 70.58] | +2.16 |
| MERL | Full Fine-tuning | 87.46 [82.24, 92.23] | −6.23 | 68.33 [65.73, 70.86] | +1.88 |
| MERL | VPT | 82.83 [75.96, 86.39] | −1.60 | 69.38 [66.04, 71.78] | +0.83 |
| MERL | Logit Pooling | 71.39 [67.21, 72.32] | +9.84 | 68.12 [65.44, 70.12] | +2.09 |
| MERL | Ours | 81.23 [77.79, 87.74] | — | 70.21 [66.61, 72.52] | — |
W3 & L2: Meaning and limitations of variable-length support
We agree that the scope of "variable-length" should be stated more precisely. In the current formulation, it means that a model adapted once at a maximum duration can process different input durations up to without retraining. This property is evaluated by training at 180 seconds and testing at 10, 30, 60, 120, and 180 seconds. It does not imply unrestricted extrapolation beyond the finite global positional-embedding table.
We will revise the claim accordingly and explicitly acknowledge that segment indices beyond the maximum learned length are unsupported by the current implementation. Positional mechanisms that support extrapolation beyond the trained horizon, together with streaming signal processing, are important future directions.
To evaluate generalization within the trained maximum more directly, we additionally test durations that were absent from the original evaluation grid, including partial-window cases at 15, 45, and 90 seconds in VTaC.
| Backbone | Method | 15 s AUC [95% CI] | 45 s AUC [95% CI] | 90 s AUC [95% CI] |
|---|---|---|---|---|
| CSFM-Tiny | Logit Pooling | 75.48 [69.59, 81.71] | 76.45 [71.12, 82.31] | 76.70 [71.97, 82.32] |
| CSFM-Tiny | Linear Probing | 71.27 [63.83, 78.87] | 70.54 [61.68, 79.44] | 71.69 [58.27, 78.25] |
| CSFM-Tiny | Ours | 79.81 [71.40, 88.27] | 85.42 [75.68, 91.15] | 86.19 [76.74, 91.50] |
| CSFM-Base | Logit Pooling | 78.40 [71.58, 84.99] | 78.50 [69.57, 84.50] | 77.74 [70.65, 80.11] |
| CSFM-Base | Linear Probing | 79.59 [74.13, 84.82] | 78.73 [71.38, 85.63] | 76.33 [68.63, 83.38] |
| CSFM-Base | Ours | 83.56 [74.05, 88.93] | 86.25 [78.72, 90.33] | 88.38 [83.38, 93.69] |
| ECG-JEPA | Logit Pooling | 79.35 [74.14, 83.96] | 76.43 [70.21, 82.19] | 77.47 [71.22, 83.21] |
| ECG-JEPA | Linear Probing | 77.67 [75.62, 86.92] | 79.71 [73.60, 85.64] | 80.82 [72.64, 84.48] |
| ECG-JEPA | Ours | 79.60 [74.38, 83.74] | 83.30 [77.89, 88.37] | 86.47 [81.93, 90.69] |
| MERL | Logit Pooling | 62.23 [56.95, 67.86] | 68.77 [62.59, 74.95] | 70.44 [65.17, 76.51] |
| MERL | Linear Probing | 67.14 [60.34, 77.34] | 73.76 [67.83, 79.95] | 74.15 [68.10, 80.23] |
| MERL | Ours | 64.41 [60.68, 78.47] | 74.98 [68.54, 81.73] | 80.51 [75.05, 86.05] |
W4: Additional clinically relevant metrics
We agree that ROC-AUC alone provides an incomplete clinical picture, particularly for imbalanced tasks. We are adding PR-AUC and specificity on VTaC at the 180-second horizon. Given the 26.8% positive prevalence in the VTaC test set, the lower absolute PR-AUC values are therefore expected under class imbalance. Nevertheless, our method substantially improves PR-AUC over the adaptation baselines.
| Backbone | Method | ROC-AUC [95% CI] | PR-AUC [95% CI] | Specificity [95% CI] |
|---|---|---|---|---|
| CSFM-Tiny | Logit Pooling | 70.24 [55.48, 75.09] | 43.38 [31.66, 51.62] | 53.23 [45.89, 60.26] |
| CSFM-Tiny | Linear Probing | 71.54 [57.14, 77.66] | 43.43 [32.20, 52.44] | 39.08 [31.83, 46.15] |
| CSFM-Tiny | Ours | 87.58 [82.82, 91.37] | 69.82 [58.21, 80.33] | 84.62 [79.60, 88.78] |
| CSFM-Base | Logit Pooling | 73.92 [61.48, 79.68] | 45.36 [33.11, 52.72] | 51.38 [43.73, 58.74] |
| CSFM-Base | Linear Probing | 74.89 [65.34, 83.06] | 48.94 [39.81, 59.84] | 59.08 [51.63, 66.39] |
| CSFM-Base | Ours | 91.95 [88.08, 95.53] | 82.89 [73.74, 90.36] | 71.38 [65.54, 76.62] |
| ECG-JEPA | Logit Pooling | 74.12 [64.07, 78.10] | 51.62 [38.86, 64.99] | 65.23 [57.58, 72.78] |
| ECG-JEPA | Linear Probing | 77.21 [70.71, 83.32] | 56.50 [43.29, 68.25] | 61.85 [54.51, 68.89] |
| ECG-JEPA | Ours | 90.83 [86.21, 95.03] | 84.79 [76.33, 91.37] | 85.85 [81.00, 90.29] |
| MERL | Logit Pooling | 71.39 [67.21, 72.32] | 39.24 [30.13, 51.18] | 62.46 [55.10, 69.43] |
| MERL | Linear Probing | 72.97 [69.57, 81.26] | 49.31 [37.93, 62.09] | 48.00 [41.41, 55.17] |
| MERL | Ours | 81.23 [77.79, 87.74] | 65.21 [54.34, 75.16] | 72.62 [66.87, 77.90] |
Q2: Disentangling soft prompts and global positional encoding
The submitted Table 3 evaluates different positional-encoding strategies and shows that global positional encoding improves over repeating or interpolating the pretrained positional embeddings. However, because soft prompts are retained across these comparisons, Table 3 does not fully disentangle the independent and interactive contributions of soft prompts and global positional encoding. We agree that a factorial ablation provides a clearer answer.
We therefore evaluate all four combinations while keeping the frozen backbone, consistency objectives, projection heads, classifier, training data, and optimization protocol unchanged. When global positional encoding (GPE) is disabled, the pretrained positional embedding is extended through interpolation.
| Soft prompts | GPE | 10 s | 30 s | 60 s | 120 s | 180 s |
|---|---|---|---|---|---|---|
| ✗ | ✗ | 72.93 | 71.3 | 71.22 | 70.57 | 69.5 |
| ✓ | ✗ | 60.78 | 67.44 | 74.37 | 80.86 | 88.18 |
| ✗ | ✓ | 74.90 | 80.03 | 78.53 | 78.43 | 77.76 |
| ✓ | ✓ | 78.13 | 83.96 | 87.45 | 89.08 | 88.92 |
The comparison reveals complementary and interactive contributions. GPE alone improves the baseline across all durations, while soft prompts provide larger gains at longer horizons. In particular, adding GPE to soft prompts improves AUC by 17.35, 16.52 and 13.08 points at 10, 30, and 60 seconds, respectively. This indicates that soft prompts and GPE are not redundant: the prompts adapt the frozen backbone to longer horizon, whereas GPE supplies explicit segment-level temporal information that strengthens adaptation across variable durations.
We will revise the interpretation of Table 3 and report the factorial results.
L1: Computational cost and scalability
We appreciate the reviewer for raising this important point and agree that a broader characterization of computational cost would help readers understand the practical trade-offs of our method. We would first like to clarify that our intended efficiency claim is specifically about parameter-efficient adaptation, rather than reduced wall-clock training time.
As reported in Appendix B.5, we quantify the trainable parameters of our method and full fine-tuning across all four backbones. These counts include all newly introduced trainable components, including the soft prompts, global positional embeddings, projection heads, and classifier. We apologize that this analysis was not sufficiently prominent and will add a clearer reference to Appendix B.5 in the main text.
We further report cumulative storage across four tasks, normalized by one CSFM-Base backbone. “Scope” indicates the tuned components, and “Extra modules” denotes the presence of additional modules.
| CSFM-Base (157.39M) | Total params | Scope: Input | Scope: Backbone | Scope: Task head | Extra modules | |
|---|---|---|---|---|---|---|
| Total # of tasks | 4 | |||||
| (a) | Full Fine-tuning | 4.00× | ✓ | ✓ | ||
| (b) | Linear Probing | 1.00× | ✓ | |||
| Partial Tuning | 1.21× | ✓ | ✓ | |||
| Bias Tuning | 1.01× | ✓ | ✓ | |||
| (c) | Adapter | 1.06× | ✓ | ✓ | ✓ | |
| VPT | 1.09× | ✓ | ✓ | |||
| Ours | 1.11× | ✓ | ✓ | ✓ |
We nevertheless agree that trainable parameter count does not provide a complete characterization of computational cost. Although improving training speed is not a primary claim of this work, the frozen teacher and auxiliary consistency objectives introduce additional computation during adaptation. Importantly, the teacher and auxiliary loss computation are not required at inference. We will revise the manuscript to more clearly distinguish parameter efficiency from training time efficiency, and avoid implying faster training.
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors propose a framework for extending short horizon trained ECG Foundation Models (FM) to longer time horizons (180 sec) without necessarily retraining entire networks from scratch. Their paper works with the idea that short horizon models already encode relative local representations and can be reapplied over a longer horizon window. The authors use a combination of locality and dynamic consistency objectives to do so and demonstrate the efficacy of their proposed method on multiple FM backbone and on 3 long horizon ECG Tasks against a number of other baseline adaptation methods.
Strengths and weaknesses
- The work is well motivated with convincing results regarding the effect of their long horizon adaptation methods on multiple fronts. The authors demonstrate that their proposed method is noticeably better across multiple ECG tasks against existing Snapshot Aggregation and Fine-tuning based methods. They are also able to demonstrate this across signal modalities as seen in Figure 4.
- Additionally, their ablations demonstrate that the combination of the proposed consistency losses are better than either of them individually. However, it must be noted that a large portion of their improvement seems to be derived from the locality-aware consistency loss.
Questions
- Can the authors comment on the clinical necessity of the 180 second long time horizon itself on VTaC, MC-MED and CPSC2021 tasks and whether it diverges from the need for a similar window in the proposed method? Table A2 for example, demonstrates that the performance of a longer time horizon on VTaC saturates beyond 60 seconds. It would be interesting to see how the proposed method and 1 other method from Snapshot aggregation and Fine-tuning based aggregation respond to shorter time windows on all tasks. And how would the other methods other than CSFM-Tiny behave under the same settings?
- The proposed method relies on teacher-student consistency losses. Could the authors comment on any challenges encountered during training and optimization? Although this differs from online teacher-student based self-distillation methods such as DINO or BYOL, it would be useful to understand whether the proposed consistency objectives introduce any sensitivity to optimization or loss weighting.
Limitations
Yes
Final justification
The authors already had an interesting manuscript and have provided a detailed rebuttal to my questions.
Formatting concerns
None
5 comments
Many thanks for the careful and constructive comments. We address the reviewer’s concerns and questions below.
W: Relative contributions of the consistency objectives
We agree with the reviewer’s observation that the locality-aware consistency loss accounts for a larger fraction of the overall improvement. This is consistent with its intended role: the pretrained 10-second encoder already provides informative representations of local ECG morphology and rhythm, and the locality-aware objective serves as the primary semantic anchor by preserving the teacher-induced inter-segment similarity structure during adaptation.
The dynamics-aware objective addresses a complementary aspect. It encourages short segment representations to retain recording-level information. The ablation reflects that design. Appendix D.1 further shows that the high- and low-affinity segment groups both contain predictive information.
| Configuration | 10 s | 30 s | 60 s | 120 s | 180 s | Average |
|---|---|---|---|---|---|---|
| Locality-aware only | 83.62 | 87.13 | 88.42 | 89.30 | 89.00 | 87.49 |
| + Dynamics-aware | 84.10 | 88.29 | 89.01 | 89.76 | 89.50 | 88.13 |
| Gain from dynamics-aware | +0.48 | +1.16 | +0.59 | +0.46 | +0.50 | +0.64 |
We will revise the manuscript to state this division of roles more explicitly: locality-aware consistency provides the dominant semantic-transfer guidance, whereas dynamics-aware consistency contributes an additional recording-level constraint.
Q1: Clinical interpretation of the 180-second horizon
We agree that 180 seconds is not universally optimal for every task. Our objective is to determine whether a foundation model pretrained on 10-second snapshots can be adapted once to a longer horizon and subsequently used at different durations within that horizon without retraining. We selected 180 seconds as a common upper-bound benchmark for this purpose.
The saturation on VTaC beyond 60 seconds is an informative example of task-dependent duration requirements. Empirically, from 60 to 180 seconds, the AUC varies by only 0.5 percent, whereas the corresponding improvement from 10 to 60 seconds is 4.91 points using CSFM-Tiny. This interpretation is also consistent with the VTaC task formulation. Once sufficient rhythm and morphological context for adjudicating a ventricular-tachycardia alarm has been observed, additional context may provide limited information.
In contrast, tasks involving more slowly varying physiological states or physiological patterns that require temporal accumulation may benefit from longer observations. For example, in MC-MED, longer ECG observations may better summarize persistent or transient rhythm instability relevant to triage acuity. With our method, the AUC increases from 61.77 at 10 s to 68.89 at 180 s using CSFM-Base. Notably, extending the observation from 60 to 180 s still yields gains of 1.04–2.82 AUC points across the four backbones. Nevertheless, their optimal operational duration must also be selected based on clinical validation. Our central claim is therefore not that “longer is always better,” but that our framework enables flexible use of clinically appropriate durations beyond the original 10-second pretraining horizon.
The complete variable-length results are provided in Appendix B.1 (Figure A1). We reproduce representative numerical values here for convenience. Many existing adaptation methods are competitive at the horizon they were tuned for, but generalize poorly to substantially shorter inputs. For example, on VTaC with CSFM-Tiny, VPT achieves 88.18 AUC at 180 seconds but decreases to 60.78 at 10 seconds, whereas our single adapted model leads at every duration. This is precisely the variable-length behavior the method is designed to provide.
Varied-horizon comparison using CSFM-Tiny
| Task | Method | 10 s | 30 s | 60 s | 120 s | 180 s |
|---|---|---|---|---|---|---|
| VTaC | Token Pooling | 79.23 | 77.94 | 75.71 | 74.25 | 74.05 |
| Logit Pooling | 78.23 | 77.45 | 75.51 | 74.14 | 73.83 | |
| Full Fine-tuning | 64.10 | 63.26 | 70.89 | 75.42 | 79.01 | |
| Linear Probing | 72.93 | 71.30 | 71.22 | 70.57 | 69.50 | |
| Partial Tuning | 64.94 | 65.84 | 69.80 | 80.79 | 86.49 | |
| Bias Tuning | 68.32 | 68.70 | 65.40 | 65.32 | 64.43 | |
| Adapter | 67.63 | 70.37 | 69.70 | 77.12 | 79.33 | |
| VPT | 60.78 | 67.44 | 74.37 | 80.86 | 88.18 | |
| LSTM Tuning | 79.04 | 82.53 | 84.28 | 84.22 | 84.97 | |
| Ours | 84.10 | 88.29 | 89.01 | 89.76 | 89.50 | |
| MC-MED (ED) | Token Pooling | 64.10 | 68.77 | 69.61 | 70.32 | 70.80 |
| Logit Pooling | 65.49 | 69.00 | 70.16 | 70.61 | 71.15 | |
| Full Fine-tuning | 63.31 | 67.13 | 68.76 | 70.45 | 70.81 | |
| Linear Probing | 62.72 | 66.12 | 67.31 | 68.91 | 69.38 | |
| Partial Tuning | 62.30 | 67.52 | 69.95 | 71.68 | 70.91 | |
| Bias Tuning | 63.23 | 65.74 | 66.71 | 67.61 | 68.13 | |
| Adapter | 63.60 | 68.24 | 69.49 | 70.44 | 71.24 | |
| VPT | 58.61 | 66.75 | 69.16 | 70.77 | 71.19 | |
| LSTM Tuning | 52.43 | 65.07 | 66.95 | 70.13 | 71.31 | |
| Ours | 64.38 | 69.55 | 71.12 | 71.88 | 72.02 | |
| MC-MED (Acuity) | Token Pooling | 58.77 | 59.09 | 60.2 | 60.92 | 61 |
| Logit Pooling | 59.19 | 59.82 | 60.25 | 60.41 | 60.13 | |
| Full Fine-tuning | 62.1 | 61.89 | 63.02 | 63.54 | 64.8 | |
| Linear Probing | 58.38 | 60.78 | 60.01 | 60.56 | 60.66 | |
| Partial Tuning | 61.4 | 62.07 | 63.09 | 65.33 | 63.43 | |
| Bias Tuning | 51.65 | 52.12 | 55.63 | 56.35 | 56.71 | |
| Adapter | 60.31 | 59.36 | 60.02 | 61.42 | 61.55 | |
| VPT | 56.33 | 60.39 | 61.51 | 63.38 | 64.5 | |
| LSTM Tuning | 51.08 | 58.29 | 61.66 | 60.98 | 61.97 | |
| Ours | 60.17 | 62.54 | 64.14 | 64.74 | 65.18 | |
| CPSC2021 | Token Pooling | 95.89 | 96.74 | 96.72 | 96.79 | 96.81 |
| Logit Pooling | 97.00 | 97.42 | 97.37 | 97.28 | 97.23 | |
| Full Fine-tuning | 90.08 | 93.54 | 93.17 | 95.13 | 94.24 | |
| Linear Probing | 97.87 | 97.01 | 96.7 | 96.54 | 96.46 | |
| Partial Tuning | 92.14 | 95.12 | 95.43 | 96.16 | 95.48 | |
| Bias Tuning | 95.38 | 97.39 | 98.42 | 98.44 | 98.46 | |
| Adapter | 91.09 | 96.16 | 97.92 | 98.02 | 98.01 | |
| VPT | 89.54 | 96.41 | 98.52 | 98.69 | 98.67 | |
| LSTM Tuning | 97.09 | 98.48 | 98.00 | 98.13 | 98.75 | |
| Ours | 97.24 | 98.91 | 99.23 | 98.90 | 98.86 |
Following the reviewer’s suggestion, we additionally evaluate CSFM-Base, ECG-JEPA, and MERL under the same duration protocol. The complete results will be released with the revised manuscript.
Duration behavior across foundation-model backbones
| Task | Backbone | 10 s | 30 s | 60 s | 120 s | 180 s |
|---|---|---|---|---|---|---|
| VTaC | CSFM-Tiny | 84.10 | 88.29 | 89.01 | 89.76 | 89.50 |
| VTaC | CSFM-Base | 87.38 | 89.15 | 89.50 | 90.85 | 91.23 |
| VTaC | ECG-JEPA | 78.86 | 82.93 | 86.09 | 89.36 | 91.02 |
| VTaC | MERL | 61.23 | 76.03 | 80.27 | 83.68 | 82.60 |
| MC-MED ED | CSFM-Tiny | 64.38 | 69.55 | 71.12 | 71.88 | 72.02 |
| MC-MED ED | CSFM-Base | 64.57 | 69.90 | 72.07 | 72.39 | 72.89 |
| MC-MED ED | ECG-JEPA | 66.32 | 67.96 | 72.77 | 73.96 | 72.48 |
| MC-MED ED | MERL | 56.92 | 64.77 | 68.03 | 69.15 | 69.92 |
| MC-MED Acuity | CSFM-Tiny | 60.17 | 62.54 | 64.14 | 64.74 | 65.18 |
| MC-MED Acuity | CSFM-Base | 61.77 | 65.90 | 66.07 | 67.39 | 68.89 |
| MC-MED Acuity | ECG-JEPA | 60.73 | 64.06 | 65.89 | 66.22 | 67.53 |
| MC-MED Acuity | MERL | 56.43 | 59.24 | 60.24 | 61.85 | 62.39 |
| CPSC2021 | CSFM-Tiny | 97.24 | 98.91 | 99.23 | 98.90 | 98.86 |
| CPSC2021 | CSFM-Base | 96.72 | 98.24 | 98.74 | 99.05 | 99.56 |
| CPSC2021 | ECG-JEPA | 85.68 | 87.02 | 92.97 | 94.29 | 94.66 |
| CPSC2021 | MERL | 79.69 | 89.29 | 92.41 | 93.79 | 93.49 |
Q2: Training stability of the consistency objectives
We thank the reviewer for this important practical question. We first clarify that the two consistency objectives use the pretrained model differently. The locality-aware objective directly preserves the inter-segment similarity structure induced by the frozen 10-second teacher. In contrast, in the dynamics-aware objective, the pretrained model is used only to identify the two segment subsets; the consistency target itself is the recording-level representation produced by the student.
The main optimization challenge was balancing the three objectives, as the supervised, locality-aware, and dynamics-aware losses operate at different numerical scales. We therefore found that their relative weighting affects final predictive performance. As reported in Appendix Table A5, the average VTaC AUC is 84.15, 85.88, 88.13, and 86.34 for , respectively. Thus, the method is not entirely insensitive to loss weighting. We selected the loss weights empirically based on the model performance. We will further expand this discussion in the final version.
For the dynamics-aware objective, we apply stop-gradient to the recording-level target to prevent symmetric co-adaptation and stabilize local-to-global learning, following the asymmetric optimization used in BYOL [1], DINO [2], SimSiam [3], and I-JEPA [4]. What differs our method with their method are different branch and different augmentation. Unlike these methods, our two branches represent different temporal scales: local segments and the complete recording, and our views are constructed through a teacher-guided affinity partition rather than generic cropping augmentation or masking. Our novelty therefore lies in this teacher-guided local-to-global objective for model adaptation, while stop-gradient serves as the stabilization mechanism.
References.
[1] Grill et al., “Bootstrap Your Own Latent: A New Approach to Self-Supervised Learning,” NeurIPS 2020.
[2] Caron et al., “Emerging Properties in Self-Supervised Vision Transformers,” ICCV 2021.
[3] Chen and He, “Exploring Simple Siamese Representation Learning,” CVPR 2021.
[4] Assran et al., “Self-Supervised Learning from Images with a Joint-Embedding Predictive Architecture,” ICCV 2023.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We thank the reviewer for recognizing the clinical motivation and clarity of our work. The comments also reveal several aspects that were insufficiently prominent in the submission. We clarify these points below and will revise the presentation accordingly.
Thanks for the comments.
Clinically, we agree that it is important to clarify the scenarios when longer ECG observations are useful. Our motivation comes from two perspectives. Physiology-knowledge-driven: in some applications, a 10-second snapshot may not be sufficient to capture intermittent abnormalities. For example, paroxysmal AF may not be present in an arbitrary short segment, motivating the use of longer dynamic recordings in CPSC2021. Consistent with this clinical motivation, increasing the input duration from 10 to 180 seconds improves ECG-JEPA’s AUC from 85.68 to 94.66. Data-driven: some downstream tasks empirically benefit from accumulating more temporal evidence. For MC-MED acuity prediction, performance improves progressively. Increasing the input duration from 10 to 180 seconds improves AUC from 60.17 to 65.18 with CSFM-Tiny, 56.43 to 62.39 with MERL, 61.77 to 68.89 with CSFM-Base, and 60.73 to 67.53 with ECG-JEPA.
Please note that in line with Reviewer 51AV Q1, we propose a framework to extend the capability of existing foundation models to "longer-horizons", rather than saying "long-horizons". This is because we understand extremely long horizons such as Holter recordings will incur additional computational cost, requiring non-trivial technical contributions to address. We mentioned this briefly in the original version (Line 353-358, Conclusion section), and we will make it clear in the final version.
We also appreciate the suggestion concerning wearable and single-lead models. However, publicly evaluable foundation models pretrained directly on long-term wearable ECG waveforms remain limited, except some proprietary work. For example, Apple pretrained foundation models on Apple Watch ECG and PPG waveforms, but we could not identify a publicly released checkpoint compatible with our evaluation [1]. In contrast, Google’s wearable LSM operates on per-minute streams such as heart rate and HRV rather than raw ECG waveforms [2].
References.
[1] Abbaspourazad et al., “Large-scale Training of Foundation Models for Wearable Biosignals,” ICLR 2024.
[2] Narayanswamy et al., “Scaling Wearable Foundation Models,” ICLR 2025.