Benchmark Recovery Does Not Certify a Frozen Tool-Trigger Contract After Quantization
Rui Li, Shuang Cao
NeurIPS 2026
TL;DR. Recovering benchmark accuracy after LLM quantization does not guarantee reliable tool-trigger decisions; a boundary-aware repair reduces this drift.
Abstract. Quantizing an action-bearing language model changes the scores that trigger tool calls, even when benchmark accuracy recovers. We audit this interface by freezing full-precision action labels, matching candidate training and threshold-retuning privileges, and evaluating held-out decision disagreement alongside externally labeled action errors. On Llama-3.1-70B and Qwen-2.5-72B at W4A16, standard-loss quantization-aware training plus threshold search recovers MMLU to within 0.3 points of FP16, while false tool-trigger rates at matched 90% recall remain 4.2 and 3.8 percentage points higher. A second controller with different actions and logistic-head scores reproduces this quality/action dissociation. Frontier-Aware Quantization (FAQ) combines boundary-sensitive precision allocation, a frontier-preservation loss, and threshold retuning; at the same 500-step budget it reduces frontier disagreement by 3.8/3.9 points and tool error by 2.1/2.0 points relative to the matched control. Separately labeled retrieval and stopping tests show corresponding action-level gains. Within FAQ, removing the frontier loss leaves Llama MMLU unchanged while raising disagreement by 3.6 points, isolating an improvement that benchmark quality misses. Repeated buffers establish the result's stability, while the precision sweep identifies substantially smaller action-error excesses at W8A8. These findings establish a concrete acceptance protocol that pairs recovered language-model quality with reference preservation and task-grounded action tests.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:42 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper investigates whether achieving general benchmark performance, such as on the MMLU, following post-training quantization is sufficient to ensure the reliability of a deployed, threshold-based tool-trigger interface. To explore this issue, the authors propose a frozen-interface audit protocol that stress-tests the quantized Llama-3.1 and Qwen-2.5 models against a stringent, full-precision reference standard. In the core case study, standard compression techniques allow large models to maintain near-baseline MMLU scores. However, these models show significant behavioral instability, leading to high rates of false tool triggers and crossing boundaries. To address this problem, the authors introduce Frontier-Aware Quantization (FAQ) as a bounded repair method to partially reduce this gap.
This paper has received three reviews, each scoring a "borderline accept." Although this score is slightly below the acceptance threshold, most reviews are positive, indicating that the strengths of this study slightly outweigh its weaknesses. I strongly encourage the authors to engage in a productive discussion with the reviewers to improve the chances of acceptance.
Notably, all reviewers pointed out that the FAQ method lacks a critical control baseline. They also expressed concerns about the experimental premise, which is based on a single frozen four-action controller, as well as the small, fixed audit buffer. Additionally, comments about extending the W4A16 quantization setting to other bit widths (such as W4A8 and W8A8) and discussing the FCR metric could be relevant to address. Overall, all reviewers have provided a series of questions that will help the authors organize clear and detailed responses.
Final justification
The rebuttal was productive and allowed the authors to respond thoroughly to the reviewers' comments. Given that the final reviews are positive, with Q-C-S-O criteria ratings ranging from good to excellent, I recommend accepting the paper. For the revised version, I encourage the authors to incorporate the clarifications from their rebuttal as well as any additional experiments.
Additional Information
Please double-check the following reference in the revised version of this paper:
- Zhao et al.: The reference appears to be legitimate, but the authors' names are listed incorrectly. The correct authors should be: Wenting Zhao, Xiang Ren, Jack Hessel, Claire Cardie, Yejin Choi, and Yuntian Deng.
Read meta-review
Meta-review
This paper investigates whether achieving general benchmark performance, such as on the MMLU, following post-training quantization is sufficient to ensure the reliability of a deployed, threshold-based tool-trigger interface. To explore this issue, the authors propose a frozen-interface audit protocol that stress-tests the quantized Llama-3.1 and Qwen-2.5 models against a stringent, full-precision reference standard. In the core case study, standard compression techniques allow large models to maintain near-baseline MMLU scores. However, these models show significant behavioral instability, leading to high rates of false tool triggers and crossing boundaries. To address this problem, the authors introduce Frontier-Aware Quantization (FAQ) as a bounded repair method to partially reduce this gap.
This paper has received three reviews, each scoring a "borderline accept." Although this score is slightly below the acceptance threshold, most reviews are positive, indicating that the strengths of this study slightly outweigh its weaknesses. I strongly encourage the authors to engage in a productive discussion with the reviewers to improve the chances of acceptance.
Notably, all reviewers pointed out that the FAQ method lacks a critical control baseline. They also expressed concerns about the experimental premise, which is based on a single frozen four-action controller, as well as the small, fixed audit buffer. Additionally, comments about extending the W4A16 quantization setting to other bit widths (such as W4A8 and W8A8) and discussing the FCR metric could be relevant to address. Overall, all reviewers have provided a series of questions that will help the authors organize clear and detailed responses.
Final justification
The rebuttal was productive and allowed the authors to respond thoroughly to the reviewers' comments. Given that the final reviews are positive, with Q-C-S-O criteria ratings ranging from good to excellent, I recommend accepting the paper. For the revised version, I encourage the authors to incorporate the clarifications from their rebuttal as well as any additional experiments.
Additional Information
Please double-check the following reference in the revised version of this paper:
- Zhao et al.: The reference appears to be legitimate, but the authors' names are listed incorrectly. The correct authors should be: Wenting Zhao, Xiang Ren, Jack Hessel, Claire Cardie, Yejin Choi, and Yuntian Deng.
1 comment
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 4/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper addresses the central challenge of whether benchmark recovery after quantization is sufficient to certify preservation of a deployed tool-trigger interface. The authors propose a frozen-interface audit protocol and studies several quantization approaches on instruction-tuned LLMs. The main finding is that models can recover MMLU performance after quantization while still exhibiting substantial changes in tool-trigger behavior under a fixed controller.
Strengths and weaknesses
The paper asks a very concrete and practically relevant question that is often overlooked in quantization research. I appreciate that the authors carefully separate the main claim from the FAQ repair method and repeatedly discuss the limitations of their study. The experimental protocol is well documented and appears reproducible. The distinction between benchmark recovery and interface preservation is clearly motivated and supported by the reported results. Negative results are rarely published, but this one could be useful for practitioners deploying quantized LLM systems. For the weaknesses, the claims of the paper are intentionally narrow, however it remains unclear to what extent the observations generalize beyond the single controller architecture considered in the paper. The proposed FCR metric treats the FP16 controller as the reference. While this is reasonable for deployment auditing, it also means that lower FCR does not necessarily imply better real-world decisions. The paper acknowledges this, but the practical implications deserve more discussion I think. The audit buffer consists of 2048 examples. Since the paper focuses on relatively rare boundary-crossing events, I wonder how sensitive the reported conclusions are to the particular audit set construction. The missing crossed QAT + τ-search baseline is mentioned several times by the authors themselves. Because of this omission, the contribution of the frontier-aware loss remains somewhat difficult to isolate. Most of the evidence comes from W4A16 experiments. It would be interesting to better understand whether the same phenomenon persists under different quantization settings and deployment scenarios. In summary: This is an Interesting paper and probably correct, but the empirical scope is a bit too narrow for me to be fully convinced. The entire story is built around essentially one controller design.
Questions
Answers to these questions would be intersting: How sensitive are the results to the choice of the boundary parameter ? Have the authors considered evaluating the protocol on a second controller design with different action semantics? Is there any indication that the observed interface instability correlates with calibration metrics such as ECE or Brier score?
Limitations
Yes.
Formatting concerns
I did not notice any major formatting or anonymity violations.
2 comments
Thank you for your careful review. Below we respond to each of your concerns in turn.
1. Second controller and generality. We ran the full audit on Controller B, whose three actions (api_call, clarify, escalate) and answer_directly alternative differ from the submitted four-action wrapper. Its scores are probabilities from a frozen temperature-calibrated logistic head; FP16 thresholds target 0.80/0.70/0.90 precision, and quantized thresholds are retuned only on calibration data against frozen FP16 decisions. The independent 3,072-turn buffer is split 1,536/768/768, shares no source conversations with the original buffer, and has an untouched report split. On Llama-70B, FP16/GPTQ+/QAT+/FAQ api_call FTR is ; corresponding FCR$_B$ is for the quantized rows. Qwen-72B gives FTR and FCR$_B$ . MMLU is within 0.3--0.8 of FP16 while externally labeled action error is 3.4--3.8 points higher (). Thus the benchmark-close/interface-unstable pattern transfers across action, score, and threshold semantics. FCR$_B$ averages three frontiers and is not compared numerically with the original four-frontier FCR.
2. Sensitivity to . Eq. 2 contains no : headline FCR and BFCL FTR use the full report split, so affects only Figure 3's localization and FAQ's training subset. Retraining FAQ at gives Llama-70B FCR and FTR , versus invariant GPTQ+ . Qwen-72B gives FCR and FTR , versus . The complete ordering is unchanged at all four bands; GPTQ+ remains 3.7/3.3 FTR points above FP16. Band mass grows from 9.4% to 63.8% on Llama, explaining why FAQ is weakest at 0.10 without changing the negative result. Appendix Table A8 reports the full band/interior decomposition.
3. ECE and Brier. We evaluated tool-frontier calibration on the same BFCL-labeled report turns. Threshold search cannot change either threshold-free metric: Llama GPTQ and GPTQ+ share ECE and Brier while FCR changes 23.7 to 16.1; QAT and QAT+ share 0.048/0.124 while FCR changes 17.3 to 16.6. Pooled Spearman correlations with FCR are only 0.51 (ECE) and 0.47 (Brier), with ECE correlation 0.24 within model family. More decisively, an ECE-optimized temperature arm reaches ECE/Brier 0.037/0.117, better than FP16's 0.041/0.118, yet has FCR and FTR , 4.8 FTR points above FP16. Qwen reproduces this (0.034/0.109, FCR 17.0, FTR 12.0). Calibration is informative but does not certify the frozen action contract.
4. FCR's practical meaning. We now pair preservation with external tests. Retrieve uses a retrieval-necessity proxy and false-trigger rate at matched 90% recall over 61.3% eligible turns; stop uses the reference turn boundary and premature-stop rate over 78.4%. On Llama, FP16/GPTQ+/FAQ are and ; Qwen gives and . Under a deliberately mis-specified FP16 tool threshold, FAQ still improves FCR by 3.3 points but its external FTR rises to 16.6. Section 3 therefore states the operational rule: FCR certifies interface sameness only; deployment acceptance also requires the benchmark anchor and externally labeled frontier tests.
5. Missing control, audit-set dependence, and deployment settings. Matched QAT+ at the identical 500-step/held-out-threshold privilege yields FCR/FTR (Llama) and (Qwen); FAQ improves these by 3.8/2.1 and 3.9/2.0 points, while the control itself remains only 0.3 MMLU below FP16 but 4.2/3.8 FTR points above it. Five fresh 2,048-turn buffers preserve ordering in 5/5; a size sweep places within 0.2 FCR points of ; ten cal/report repartitions never reduce FAQ's gap below 2.6 points. Comparator-complete W4A8 fails the tool test, W8A8 passes, and three added shifts (tool schema, task-oriented dialogue, non-English) preserve the method ordering. These completed evaluations are reported in revised Table 1 and Appendix Tables A7--A11.
Thank you for the detailed rebuttal and the substantial additional experiments. The new evaluation with a second controller addresses my main concern regarding the generality of the observed interface instability. The sensitivity analysis, the additional calibration results, the matched QAT+ baseline, the repeated audit-set experiments, and the evaluation under further quantization settings and distribution shifts also answer convincingly to my remaining questions. In particular, the new externally labeled frontier tests make the practical interpretation and limitations of FCR more clear. Overall, the rebuttal has substantially strengthened the empirical evidence and resolved my main concerns. I therefore maintain my positive assessment and would now tend more clearly towards acceptance.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper argues that benchmark-close post-training quantization does not certify preservation of a frozen score-to-action LLM controller, and it operationalizes that claim through frontier crossing rate under fixed FP16 thresholds plus held-out threshold retuning for quantized models. The core evidence is a W4A16 case study where two large models retain near-FP16 MMLU after GPTQ plus tau-search while still showing 11.9 and 10.9 false tool-trigger rates and 16.1 and 15.4 aggregate FCR on a frozen report split. Baseline EV versus benchmark-only SOTA = 0.65, computed as scoped contradiction rate 1.00 across the two retained large-model W4A16 rows multiplied by a confidence factor of 0.65 after a 0.35 discount for one controller, N = 2048 audit buffer, missing matched QAT plus tau-search control, one prompt shift, and two preservation-only frontiers.
Strengths and weaknesses
The core negative result is the paper's strongest component. The claim that MMLU recovery does not certify preserved tool-trigger behavior under the studied W4A16 controller has validity probability 0.86, supported by direct labeled BFCL frontier evidence. The result is narrow and clean: GPTQ plus tau-search remains within 0.8 MMLU points of FP16 on two large models while the tool frontier remains unstable. The FCR metric has validity probability 0.80 as an operational metric for frozen controller preservation because it is defined as sign disagreement under frozen thresholds. Its limitation is equally clear: FCR measures preservation, not external correctness.
FAQ is useful as reducibility evidence, not as an isolated algorithmic result. The claim that FAQ reduces FCR under the same frozen protocol has validity probability 0.72, supported by seeded W4A16 results and ablation. FAQ improves Llama-3.1-70B FCR from 16.1 to 12.8 versus GPTQ plus tau-search, but the missing matched QAT plus tau-search row blocks causal isolation of the frontier loss. KILL-CRITERIA for report-split contamination have violation probability 0.12 under the stated protocol because the text says D_rep is untouched by PTQ calibration, backpropagation, and threshold tuning; raw split files are still needed to verify the claim. The audit buffer has zero validity as a deployment-prevalence estimator, and the paper correctly limits it to paired stress testing.
Clarity is high because the paper repeatedly limits its claim. Scope boundedness to one frozen four-action controller and W4A16 as the only comparator-complete regime has validity probability 0.92. The paper avoids overstating W4A8/W8A8 or FAQ as a general quantizer. Metric separation has validity probability 0.82 because tool and abstain are externally labeled while retrieve and stop remain preservation-only; the table captions and limitations make that evidentiary split explicit.
Significance is positive for deployment acceptance testing. The audit protocol has validity probability 0.74 as a useful change to acceptance testing for action-bearing compressed LLMs because it exposes a failure mode hidden by benchmark-only acceptance. The algorithmic-advance claim for FAQ has validity probability 0.45 because FAQ is a repair bundle rather than an isolated primitive, with matched QAT plus tau-search missing.
Originality lies in the evaluand, not the compressor. The frozen-interface audit has validity probability 0.78 as an orthogonal vector relative to standard quantization recovery. The contribution is not a new compressor; it is a deployment evaluand that existing quantization papers do not center. FAQ's low-overlap claim has validity probability 0.42 because it overlaps heavily with mixed precision, QAT, threshold calibration, and margin-preservation losses.
Questions
- Add the missing matched QAT plus tau-search row under the identical 500-step update budget and held-out threshold privilege; quality increases only if FAQ still beats that row by at least 2.0 FCR points and 1.0 FTR point on both large W4A16 models.
- Release exact train/cal/report split sizes, split hashes, threshold grids, and frozen FP16 sign labels for the 2,048-example audit buffer; quality decreases if any report item enters PTQ calibration, threshold search, or gradient updates.
- Provide an epsilon sensitivity table for boundary bands epsilon in {0.1, 0.25, 0.5, 1.0}; significance increases only if the FCR ordering remains invariant and the BFCL tool FTR result remains above FP16 by at least 2 percentage points for GPTQ plus tau-search.
- Add a second controller family with different action scores and thresholds; rating increases to 5 only if the benchmark-close/interface-unstable pattern repeats under an untouched report split.
- Add external correctness labels or task-grounded proxies for retrieve and stop; otherwise aggregate FCR must remain a preservation-only secondary metric.
Limitations
The authors identify limitations, and the remaining confidence discounts are concentrated in scope and attribution. A single four-action controller creates controller-specific effect sizes; probability of occurrence = 0.65 and confidence discount = 0.12. The missing matched QAT plus tau-search control confounds FAQ attribution; probability = 0.90 and discount = 0.08. The N = 2048 audit buffer can under-sample rare frontier failures; probability = 0.45 and discount = 0.05.
The external-validity limitations remain material. Retrieve and stop lack external correctness labels; probability = 0.70 and discount = 0.05. WildChat is the only prompt-distribution shift; probability = 0.60 and discount = 0.04. Raw conversations and restricted assets constrain independent replication; probability = 0.40 and discount = 0.01.
Formatting concerns
Zero violations detected.
1 comment
Thank you for your careful review. Below we answer the five requested items and their explicit score-change conditions.
1. Exact crossed QAT + -search control. We ran standard-loss QAT (), uniform W4, no mixed precision or boundary stratification, for the identical 500 AdamW+STE steps on audit-train, followed by the identical held-out per-frontier sweep. Llama-70B QAT+ obtains FCR/FTR/AbsAcc ; Qwen-72B obtains . FAQ obtains and , beating the crossed row by 3.8/2.1 and 3.9/2.0 points, above your 2.0/1.0 condition; paired 95% CIs for FCR are and (). The crossed row remains only 0.3 MMLU below FP16 yet exceeds FP16 FTR by 4.2 and 3.8 points, so it strengthens the primary counterexample. Threshold search reduces GPTQ/QAT/FAQ FCR by 7.6/0.7/0.8 points on Llama and 6.7/0.7/0.8 on Qwen. Together with the FAQ ablation (16.4 versus crossed 16.6), this isolates a frontier-loss-conditional repair bundle; we do not claim a novel primitive.
2. Split release and contamination kill-criterion. The 2,048 turns are split 1,024/512/512 train/cal/report (4,096/2,048/2,048 frontier decisions). The released manifest contains each normalized-turn SHA-256, split, four FP16 signed distances to , frozen signs, per-seed crossing indicators, seeds 13/21/34, PTQ-calibration-set hash, and mixed-precision schedules. To make the grid definition exact, each frontier's calibration margins are standardized, is swept at 0.01 increments (601 values), and the selected value is mapped back to raw logits; ties choose the larger threshold. The raw FP16 thresholds are Llama and Qwen . Intersections of all 512 report hashes with (i) the 128-sequence PTQ set, (ii) train, (iii) cal, (iv) threshold logs, and (v) every 500-step gradient index across all seeds/arms are all zero; no cross-split MinHash Jaccard reaches 0.80 (maximum 0.41). Thus no report item enters calibration, threshold search, or training.
3. sensitivity and your significance condition. Eq. 2 and BFCL FTR do not contain ; only FAQ's boundary subset and the localization plot change. At , FAQ FCR is on Llama and on Qwen, while GPTQ+ stays 16.1/15.4 and the crossed control 16.6/16.0. The complete ordering is invariant. GPTQ+ FTR stays 11.9 versus FP16 8.2 and 10.9 versus 7.6: excesses of 3.7 and 3.3 points, above your 2-point condition at every band.
4. Second controller family. Controller B uses three different actions, a frozen temperature-calibrated logistic head, precision-target FP16 thresholds, and an independent 3,072-turn buffer split 1,536/768/768. Its report split has zero overlap with any adaptation input. Llama FP16/GPTQ+/QAT+/FAQ api_call FTR is , with FCR$_B$ for quantized rows; Qwen gives FTR and FCR$_B$ . MMLU remains within 0.3--0.8 of FP16 while labeled action error increases by 3.4--3.8 points (). This meets the stated rating condition under an untouched report split; FCR$_B$'s three-frontier denominator is kept separate.
5. Retrieve and stop correctness. Retrieve now uses a retrieval-necessity proxy and false retrieval-trigger rate at 90% recall over 61.3% eligible turns; stop uses the reference turn boundary and premature-stop rate at 90% recall over 78.4%. Llama FP16/GPTQ+/QAT+/FAQ are and ; Qwen gives and . External excess and preservation rank-correlate at 0.83 , not unity, so aggregate FCR remains secondary and separately denominated.
The remaining stated discounts were also tested: five fresh buffers preserve ordering in 5/5; is within 0.2 FCR points of ; three added prompt shifts plus WildChat show no inversion; and the populated manifests and deterministic reconstruction script replace the prior schema-only artifact. Revised Table 1 and Appendix Tables A7--A12 contain these results.
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper studies whether benchmark-close post-training quantization is sufficient to preserve the behavior of a deployed thresholded action interface. It proposes a frozen-controller audit in which full-precision action-frontier labels and thresholds define a reference contract, while quantized models may retune thresholds on a held-out calibration split before being evaluated on an untouched report split. In the main W4A16 case study, Table 1 reports that the large-model GPTQ plus threshold-search rows stay close to FP16 on MMLU, but still have nontrivial BFCL-grounded tool false-trigger rates and aggregate Frontier Crossing Rate (FCR). Frontier-Aware Quantization (FAQ) is presented as a bounded repair probe rather than the central method claim.
Strengths and weaknesses
The strongest part of the paper is the choice of evaluation target. A frozen tool-trigger/action contract is closer to what would actually be shipped than an average MMLU recovery number. In Table 1, for example, Llama-3.1-70B with GPTQ plus threshold search keeps MMLU at 78.4 versus 79.2 for FP16, but still reports FCR 16.1 and FTR 11.9; the corresponding Qwen-2.5-72B row has MMLU 81.5 versus 82.3 for FP16, with FCR 15.4 and FTR 10.9. This is a clean way to show why benchmark recovery is not the same object as interface preservation. The paper also separates externally grounded tool/abstain evidence from retrieve/stop, which are preservation-only frontiers, and avoids selling FAQ as a standalone quantization method.
The weaknesses are not about the existence of the reported gap, but about how far it can be generalized and how cleanly FAQ can be interpreted. The main evidence comes from one four-action controller, one 2,048-example audit buffer, and one main retained benchmark anchor. Table 3 is suggestive for FAQ because removing the frontier loss raises FCR from 12.8 to 16.4 and plain QAT is 17.3, but the paper still lacks the most informative crossed control: matched QAT plus threshold search under the same privilege. Table 4 gives some shift evidence, but it is still limited: the GPTQ plus threshold-search row moves from 16.1 in-distribution FCR to 20.3 on WildChat, and FAQ from 12.8 to 15.6. Reproducibility is also partial: the supplementary artifact reproduces shareable figures, tables, manifests, and manuscript build, but its own notes state that raw audit conversations, populated manifests, model checkpoints, and full PTQ/QAT/FAQ training reruns are not included. Finally, aggregate FCR should be read as interface-preservation context, not direct correctness evidence for retrieve and stop.
Questions
- Does the main conclusion still hold under a matched Quantization-Aware Training (QAT) plus threshold-search control, not only GPTQ plus threshold search?
- How sensitive are Frontier Crossing Rate (FCR) and the tool-trigger result to the audit buffer construction, epsilon boundary band, and action prevalence?
- Can retrieve and stop be externally validated, or can the paper more strongly separate them from the score-carrying tool and abstain evidence?
- Do the same benchmark-close but interface-unstable patterns appear for another controller family or action-interface design?
For me, the largest score-moving response would be a matched QAT plus threshold-search crossed control. I would also update upward for a sensitivity analysis over the audit buffer/boundary band or for evidence from another controller family. I would update downward if the gap is shown to be calibration-buffer-specific, or if the crossed control eliminates the main interface gap.
Limitations
Yes. The paper discusses the single-controller setup, audit-buffer dependence, limited shift evidence, smaller W8A8 gap, and single hardware stack. The final review should still emphasize that these are external-validity limits rather than minor caveats.
Final justification
Resolved - critical control: The rebuttal adds the matched standard-loss QAT plus held-out threshold-search control requested in my review. MMLU remains close to FP16 while the tool-trigger and interface-preservation gap persists, so this strengthens rather than eliminates the paper's central benchmark-close/interface-unstable result.
Resolved - robustness and scope: Fresh disjoint buffers, calibration/report repartitions, buffer-size and prevalence analyses, a genuinely different controller family, and comparator-complete bitwidth experiments materially reduce my concerns about calibration specificity and dependence on a single setup.
Resolved - metric interpretation: The revision now clearly limits aggregate FCR to interface preservation rather than correctness and keeps task-grounded tool evidence primary.
Remaining limitations: The evidence still covers a limited number of controller families and deployment settings, and full end-to-end reproduction remains constrained. I treat these as external-validity limitations, but they no longer outweigh the contribution after the new controls and analyses.
Recommendation: The authors satisfy the upward-update conditions stated in my original review. I therefore recommend increasing my rating from 4 to 5.
Formatting concerns
No major formatting or anonymity concern.
1 comment
Thank you for your careful review. Below we address the four questions, the downward-update conditions, and the reproducibility and shift concerns.
1. Matched QAT + -search. We ran standard-loss QAT with uniform W4 weights for the identical 500-step budget, then the identical held-out threshold sweep. Llama-70B and Qwen-72B obtain FCR/FTR and . Their MMLU is 78.9/82.0 versus FP16 79.2/82.3, yet FTR remains 4.2 and 3.8 points above FP16 (). Thus the crossed control does not eliminate the interface gap; it is a tighter benchmark-close counterexample. FAQ reaches and , improving FCR/FTR by 3.8/2.1 and 3.9/2.0 points (paired FCR CIs , ). Threshold search recovers only 0.7 FCR for QAT versus 7.6 for GPTQ, while the FAQ ablation is 16.4, supporting a frontier-loss-conditional repair-bundle interpretation.
2. Buffer construction, calibration specificity, , and prevalence. Five fresh disjoint 2,048-turn buffers, with FP16 thresholds refit and the protocol rerun, preserve ordering in 5/5: GPTQ+ 16.3 (15.4--17.4), crossed control 16.8 (15.9--17.9), FAQ 13.0 (12.1--14.0); FTR excess is 3.0--4.3 points in every buffer. Across ten cal/report repartitions, GPTQ+ is 16.2 (sd 0.6), FAQ 12.9 (sd 0.5), and the gap is (sd 0.3), never weaker than . Using a disjoint WildChat calibration pool gives 17.4 versus 13.6, so the gap is not calibration-buffer-specific. At , GPTQ+ FCR is and FAQ is .
Eq. 2 and BFCL FTR do not depend on ; only FAQ is retrained. For , FAQ FCR is (Llama) and (Qwen), always below the invariant 16.1/15.4 GPTQ+ rows. Reweighting native 18.7% tool prevalence to 5/10/30% leaves GPTQ+'s FTR excess at 3.6/3.6/3.9 and preserves ordering. Appendix Tables A8--A9 report all distributions and denominators.
3. Retrieve/stop external grounding and FCR separation. Retrieve uses a retrieval-necessity proxy and false-trigger rate at matched 90% recall on 61.3% eligible turns; stop uses the reference turn boundary and premature-stop rate on 78.4%. Llama FP16/GPTQ+/QAT+/FAQ are and ; Qwen gives and . These separately denominated projections do not promote aggregate FCR: a deliberately bad FP16 threshold leaves FAQ's 3.3-point FCR advantage unchanged while raising its external FTR to 16.6. Section 3 now states that FCR certifies preservation only; the BFCL tool frontier remains the primary correctness evidence.
4. Another controller family. Controller B uses three different actions, probability scores from a frozen logistic head, precision-target FP16 thresholds, and an independent 3,072-turn buffer split 1,536/768/768 with an untouched report split. On Llama, FP16/GPTQ+/QAT+/FAQ api_call FTR is and quantized FCR$_B$ is ; Qwen gives FTR and FCR$_B$ . MMLU stays within 0.3--0.8 of FP16 while labeled action error is 3.4--3.8 points higher (), repeating the pattern. FCR$_B$'s three-frontier denominator is never mixed with the original metric.
5. Reproducibility, shifts, and bitwidths. Populated manifests now release the 1,024/512/512 split hashes, FP16 signs/distances, standardized 601-value threshold sweeps, selected thresholds, per-seed crossings, PTQ-set hash, schedules, and seeds 13/21/34. Five intersections of report hashes with PTQ calibration, train, cal, threshold logs, and all gradient batches yield zero overlaps; maximum cross-split MinHash Jaccard is 0.41. Three new shifts plus WildChat preserve ordering: GPTQ+ moves from 16.1 to 20.3/21.6/19.1/22.4, FAQ to 15.6/16.9/14.9/17.8. Comparator-complete bitwidth suites show W4A16 and W4A8 fail, whereas W8A8 passes (tool-FTR excess Llama; Qwen), and FAQ does not separate from the retuned W8A8 controls. Section 6 records these as external-validity boundaries rather than minor caveats.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Thank you for the detailed meta-review. Below we address each decision-critical point in turn.
1. Missing matched QAT + τ-search control. We ran standard-loss QAT (λ=0, uniform W4, no boundary stratification or mixed precision) for the same 500 AdamW+STE steps, then applied the identical held-out per-frontier threshold sweep used by FAQ. On Llama-3.1-70B and Qwen-2.5-72B W4A16, this control obtains FCR/FTR of 16.6±0.7/12.4±0.5 and 16.0±0.6/11.4±0.4, respectively. FAQ gives 12.8±0.6/10.3±0.4 and 12.1±0.5/9.4±0.3: improvements of 3.8/2.1 and 3.9/2.0 points (paired 95% CIs for ΔFCR [−4.5,−3.1] and [−4.6,−3.2], p≤0.001). This exceeds the requested 2.0-FCR/1.0-FTR margin. More importantly, the control preserves MMLU within 0.3 points of FP16 (78.9 vs. 79.2; 82.0 vs. 82.3) while its BFCL FTR remains 4.2 and 3.8 points above FP16. Thus the crossed control strengthens, rather than removes, the benchmark-close/interface-unstable result. Revised Table 1 includes this row; Table 3 now cleanly shows that the λ=0 FAQ variant (16.4 FCR) is indistinguishable in scale from the crossed control (16.6), so FAQ remains described as a repair bundle whose gain is frontier-loss-conditional.
2. A genuinely different controller. Appendix Table A7 reports Controller B: three actions (
api_call,clarify,escalate) versusanswer_directly, scored by a frozen temperature-calibrated logistic head rather than Controller A's direct margins. FP16 thresholds meet action-specific precision targets (0.80/0.70/0.90); quantized thresholds are retuned only on calibration data to match the frozen FP16 decisions. Its independent 3,072-turn buffer is split 1,536/768/768 with an untouched report split and no shared source conversations. On Llama-70B, FP16/GPTQ+τ/QAT+τ/FAQapi_callFTR is 6.9/10.4/10.7/8.9, with FCR$_B$ 14.7/15.2/11.5 for the quantized rows. Qwen-72B gives FTR 6.2/9.6/9.8/8.2 and FCR$_B$ 13.9/14.3/10.8. MMLU remains within 0.3--0.8 of FP16 while the externally labeled action error rises by 3.4--3.8 points (p<0.001), reproducing the central pattern under different actions, scores, thresholds, and an untouched report split. Because K=3, FCR$_B$ is not numerically compared with the four-frontier FCR.3. Audit-buffer size and construction. Five fresh disjoint 2,048-turn buffers, each refit and rerun end to end, preserve the ordering in 5/5: GPTQ+τ FCR 16.3 (range 15.4--17.4), crossed control 16.8 (15.9--17.9), FAQ 13.0 (12.1--14.0); the tool-FTR excess is positive in every buffer. For N=512/1024/2048/4096/8192, GPTQ+τ FCR is 16.8/16.4/16.1/16.0/15.9 and FAQ is 13.5/13.1/12.8/12.7/12.6; N=2,048 is within 0.2 points of N=8,192. Ten cal/report repartitions give a FAQ gap of −3.3 with sd 0.3 (never weaker than −2.6), and prevalence reweighting to 5/10/30% leaves GPTQ+τ's FTR excess at 3.6/3.6/3.9 points. Appendix Tables A8--A9 report these analyses.
4. W4A8 and W8A8. We completed the seeded GPTQ/AWQ/QuIP#/QAT/GPTQ+τ/QAT+τ/FAQ suite on both large models. GPTQ+τ exceeds FP16 tool FTR by 3.7/3.3 points at W4A16 and 5.5/5.2 at W4A8, but only 0.5 [−0.1,1.1]/0.3 [−0.3,0.9] at W8A8. Hence W4A16 remains the tightest benchmark-close counterexample, W4A8 fails with a larger MMLU drop, and W8A8 passes. FAQ does not separate from the retuned W8A8 controls. The revised bitwidth table therefore reports a discriminating acceptance test, not a blanket claim about quantization.
5. What FCR certifies. Section 3 now states beside Eq. 2 that FCR certifies preservation, not correctness. Retrieve and stop additionally receive task-grounded projections: false retrieval-trigger rate at 90% recall on the 61.3% eligible turns and premature-stop rate at 90% recall on the 78.4% with reference boundaries. For Llama-70B, FP16/GPTQ+τ/FAQ are 9.6/13.4/11.3 and 5.2/7.8/6.5; Qwen-72B gives 8.9/12.3/10.5 and 4.7/7.1/5.9. A deliberately bad FP16 tool threshold leaves FAQ's FCR advantage unchanged at 3.3 points while raising its external FTR to 16.6, directly showing why lower FCR cannot certify a better policy. Aggregate FCR remains secondary to the externally labeled per-frontier tests.