BuresTomFlow: Bures-Geometric Flow Matching for Posterior Quantum Tomography
Lu Wei, Yufeng Wang, Chenfeng Cao, Haibin Ling
NeurIPS 2026
Abstract. Finite-shot quantum tomography often leaves a posterior over many density matrices compatible with the same measurement record, but fast reconstruction methods collapse this uncertainty to a single state. We frame this setting as amortized posterior sampling and introduce BuresTomFlow, a measurement-conditioned Flow Matching sampler for full-rank density matrices. The method transports base density matrices along Bures-Wasserstein paths on the positive matrix cone, projects the path back to the trace-one state space, and trains the velocity field with a Bures-aligned tangent loss. Thus the sampler is trained in the same fidelity-based geometry used to judge posterior quality. We evaluate BuresTomFlow in dense four-qubit simulations with count, shadow, and mixed measurement records. Against Cholesky, log-density, and generic Riemannian Flow Matching controls at comparable total runtime for training and posterior sampling, BuresTomFlow reduces Bures distance and credible-ball coverage error, and improves held-out observable prediction. In the main comparison across multiple seeds, mean Bures distance decreases from for the Cholesky baseline to for BuresTomFlow, and mean coverage error decreases from to . These results show that the value of Bures geometry is not merely enforcing physical states, but improving posterior estimates and reducing credible-ball coverage error when finite-record tomography cannot be reduced to one reconstruction.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:50 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
This paper proposes BuresTomFlow, a flow matching framework for quantum tomography. Reviewers agree that the approach is novel, well motivated, and demonstrates meaningful empirical improvements.
The main points for the rebuttal are:
(1) clarification of the geometric construction (2) discussion of scalability beyond the current four-qubit experiments. (3) discussion of comparisons with additional tomography baselines and the effects of realistic noise. (4) clarification of several presentation details.
Addressing these points would further strengthen an already promising submission.
Final justification
I have read the authors’ rebuttal and the subsequent reviewer discussion.
A significant concern raised during discussion was that the original coverage and rank-calibration results did not support the paper’s broad claim of calibrated posterior uncertainty. In particular, the authors confirmed that the originally reported coverage error corresponded to systematic overcoverage, and that the submitted rank diagnostic was non-uniform. The authors appropriately acknowledged this issue and substantially narrowed the calibration claims.
The rebuttal also adds considerable new evidence (longer training comparisons, sensitivity tests, direct posterior-to-posterior comparisons agains a reference and tests outside the original TFIM prior). These experiments continue to favor BuresTomFlow on posterior-center accuracy and, importantly, on the direct posterior-discrepancy comparison.
Overall, I view the original calibration presentation as a weakness, but the authors have been transparent about it and the additional experiments substantially strengthen the main claims. The remaining limitations, four-qubit scale, a structured prior, dense-matrix scaling, and lack of demonstrated distributional calibration, should be very clearly stated in the final paper.
Read meta-review
Meta-review
This paper proposes BuresTomFlow, a flow matching framework for quantum tomography. Reviewers agree that the approach is novel, well motivated, and demonstrates meaningful empirical improvements.
The main points for the rebuttal are:
(1) clarification of the geometric construction (2) discussion of scalability beyond the current four-qubit experiments. (3) discussion of comparisons with additional tomography baselines and the effects of realistic noise. (4) clarification of several presentation details.
Addressing these points would further strengthen an already promising submission.
Final justification
I have read the authors’ rebuttal and the subsequent reviewer discussion.
A significant concern raised during discussion was that the original coverage and rank-calibration results did not support the paper’s broad claim of calibrated posterior uncertainty. In particular, the authors confirmed that the originally reported coverage error corresponded to systematic overcoverage, and that the submitted rank diagnostic was non-uniform. The authors appropriately acknowledged this issue and substantially narrowed the calibration claims.
The rebuttal also adds considerable new evidence (longer training comparisons, sensitivity tests, direct posterior-to-posterior comparisons agains a reference and tests outside the original TFIM prior). These experiments continue to favor BuresTomFlow on posterior-center accuracy and, importantly, on the direct posterior-discrepancy comparison.
Overall, I view the original calibration presentation as a weakness, but the authors have been transparent about it and the additional experiments substantially strengthen the main claims. The remaining limitations, four-qubit scale, a structured prior, dense-matrix scaling, and lack of demonstrated distributional calibration, should be very clearly stated in the final paper.
1 comment
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
In this paper, the authors propose an interesting statistical method to reconstruct an unknown quantum state using posterior tomography. The goal is to use the posterior probability distribution to combine prior knowledge with measurement data via a Bures-geometric conditional Flow Matching sampler. It uses Bures-Wasserstein geometry to construct probability paths for interpolating between quantum density matrices, allowing for efficient generation and reconstruction of the posterior distribution of complex, high-dimensional quantum states.By matching vector fields across this Bures-geometric space, authors can sample from the posterior distribution. This yields both a Bayesian Mean Estimate of a quantum state and the exact uncertainty around it. The evaluation is performed through simulations against Cholesky, log-density, and generic Riemannian Flow Matching controls.
Strengths and weaknesses
Strengths
- Innovative and fresh: Although there are existing ML techniques for state tomography, the authors employ an unusual and original idea such as the Bures-geometric conditional Flow.
- Thorough: Extensive testing against Cholesky, log-density, and generic Riemannian Flow Matching controls.
- Curved Manifold Awareness: Bures-geometric approaches account for curved spaces (Bloch sphere). This ensures that generative paths accurately reflect the intrinsic geometry of quantum states
- The Bures metric is natively defined over the space of density matrices. This allows the framework to smoothly model, interpolate, and generate mixed quantum states and their underlying posterior distributions without losing physical validity.
Weaknesses
- Clarity of Contributions: The distinction between prior work and the authors' contributions seems blurred. This should be explicitly clarified after the introduction.
- Methodology: The approach is of limited scope. Testing is done on dense four-qubit simulations. I'd like to see if results hold on larger experiments of 10+ qubits.
- Data and Analysis: Lack of comparisson aginst other methods. I beleive it would be important to see results head to head against Shadow State Tomography, Neural Nertwork Tomography, and others (where applicable).
- Effects of Noise: Depolarizing noise (Gate, Readout), decoherence play such a big role in current generation NISQ devices; It will be interesting too see how quantum noise affects simulation results.
- Matrix Square Root Bottleneck limits scalability: Bures distance computations and geodesics require evaluating matrix square roots and solving Lyapunov equations. For high-dimensional systems (e.g., multiqubit Hilbert spaces), these iterative matrix operations severely limit scalability.
- Enforcing that reconstructed states remain valid density matrices during flow matching is computationally expensive.
Questions
- What would be the implications of simulating larger density matrices? (10+ qubits)
- Is your method comparable to others such as Shadow-Tomography or Neural Net Tomography?
- Brute force tomography requires observables. How would your collapse of posterior family of density matrices would reduce, improve or have any effect in the number of observables?
- How does the Bures metric's curvature impact the velocity field given its manifold has non-zero curvature? How do we compute and parameterize straighter probability paths along these Bures geodesics to generate valid quantum state posteriors?
- How do we handle boundary singularities where the inverse metric diverges?
- How do we measure convergence on the Bures statistical manifold to ensure the reconstructed quantum states remain valid?
Limitations
The paper could be improved with:
- Larger density matrix simulations.
- An study on the effects of noise and decoherence.
Final justification
We thank the authors for their responses to our concerns. My questions have been thoughtfully answered. I'll keep my ration of borderline accept.
Best Regards
Formatting concerns
N/A
3 comments
Rebuttal
We sincerely thank the reviewer for the careful assessment. We address each concern and question below.
All numbered citations refer to the bibliography of the submitted manuscript.
W1 — Clarity of contributions. Flow Matching [21], Riemannian Flow Matching [10], Bures–Wasserstein (BW) geometry [4, 33], shadow tomography [1], randomized measurements [14], classical shadows [18], Bayesian quantum tomography [5, 15], and neural tomography [8, 31] are prior work and play distinct roles as geometric tools, measurement protocols, or comparison classes. Our contribution is BuresTomFlow, a measurement-conditioned posterior sampler over density matrices that combines projected BW conditional paths, Bures-aligned tangent supervision, density-matrix projection, and posterior evaluation by Bures distance, credible-ball coverage, and held-out observable error. In a revision, we will revise the Contributions paragraph at the end of the Introduction and add a concise table separating prior components from our contributions and distinguishing measurement protocols, point estimators, and posterior samplers.
W2/Q1, W5, W6 — Larger systems, spectral cost, and projection. For qubits, . Dense eigendecompositions, matrix square roots, and Lyapunov solves cost . For fixed hidden width, the explicit matrix representation and the dense input/output layers scale as . Full end-to-end -qubit posterior tomography is therefore outside the current dense implementation. In the four-qubit implementation, PSD/trace-one projection accounts for of a sampling step. Practical -qubit extensions would likely require structured or low-rank state representations.
W3/Q2 — Comparison with shadow and neural tomography. We agree that measurement protocols and reconstruction algorithms must be separated, and we distinguish Aaronson's shadow tomography [1] from classical shadows [18]. We additionally evaluated the standard local-Pauli classical-shadow estimator using exactly the same snapshots as the learned sampler. The comparison uses five seeds, 32 held-out states per setting, and the same four held-out Pauli observables. These are shot-specific results from a separate shadow-only head-to-head, not the eight-regime aggregates reported in Table 1. At 4, 16, and 32 snapshots, the mean absolute observable errors are respectively , , and for classical shadows, and , , and for our posterior mean. Thus, under the tested low-shot budgets, the posterior mean has lower observable error than the classical-shadow estimator. Classical shadows are prior-free estimators designed primarily for observable prediction, whereas BuresTomFlow learns a thermal-state prior to return posterior samples over physical density matrices. We therefore present this as a matched-record comparison on held-out observables, not as a claim of general dominance over classical shadows.
We also trained a custom amortized neural density-matrix point estimator on count-32, mixed-4, and shadow-16. Within this comparison, the sampler and point estimator use the same state prior, measurement simulator, record tokenization, identical records, and the same 32 held-out states per regime. The point estimator uses the same two-block, four-head record encoder, followed by a Cholesky density-matrix head, and was trained for 2,000 steps with batch size 32 using Adam at learning rate over three random seeds. Values are mean standard deviation over the three seeds, reported in that regime order. The Bures errors of our posterior mean are , , and , respectively, while the corresponding neural point-estimator errors are , , and . BuresTomFlow is lower in two of the three tested regimes. Unlike this point estimator, it also returns posterior samples. In a revision, we will report the classical-shadow and neural point-estimator comparisons in the appendix, together with estimator definitions, seed counts, and variability.
Q3 — Number of observables. For full local-Pauli tomography, is the number of tensor-product measurement settings, while an unrestricted -qubit density matrix has real degrees of freedom. BuresTomFlow does not change the information requirement for unique identification of an arbitrary state. It can condition on a non-informationally-complete record, but the result is then a wider, more prior-dependent posterior rather than a uniquely identified point. It also does not collapse the posterior family: it returns samples, and the posterior mean is reported as a point summary, while uncertainty metrics use the full sample cloud. Measurement reductions require an additional target or assumption, such as selected observables or low rank [16, 18]. Thus, our contribution concerns amortized posterior inference and uncertainty quantification under a fixed finite record, rather than a new measurement-complexity bound.
Q4 — Curvature and the velocity field. For a pair , the positive-cone BW transport map is
With , , and , the positive-cone tangent is
The implemented target is obtained by differentiating the regularized projection . Curvature enters through this state-dependent transport map and the Lyapunov metric, so the target velocity depends nonlinearly on the state and endpoints. The network output is projected onto the Hermitian, trace-free tangent space and regresses this geometry-dependent target [10, 21]. We do not separately optimize a global straightness objective; parameterizes the analytic pairwise BW cone path. Because the trace-one density-matrix set is not a geodesic submanifold of the positive cone [33], we call a projected BW conditional path rather than an exact trace-one geodesic. These pairwise paths provide tractable conditional training targets for the learned velocity field.
Q5/Q6 — Boundary singularities, convergence, and validity. Let . In the eigenbasis of ,
The inverse therefore becomes ill-conditioned near the rank-deficient boundary [4, 33]. We move near-boundary targets into the positive-definite interior using a small identity mixture, use consistent positive eigenvalue floors in inverse-root and Lyapunov computations, and project every intermediate and terminal state onto the Hermitian, PSD, trace-one state space. We monitor trace error, Hermiticity error, and minimum eigenvalue separately from posterior accuracy.
We additionally measured numerical sensitivity rather than using physical validity as a proxy for convergence. Across the checked settings, increasing Euler integration from four to eight steps changes Bures distance by at most , indicating that the reported reconstruction ordering is not an artifact of the four-step discretization. In a representative posterior-sample sensitivity run, increasing the number of draws from 16 to 128 changes the thermal-state Bures distance from to and the robustness-state distance from to . Posterior-center accuracy is stable in this check.
W4 — State-level depolarization stress test and device-noise scope. We evaluated a simulated state-level depolarizing channel as a state-level stress test. Let denote the original four-qubit state, the depolarized state, the 16-dimensional identity, and the depolarization strength:
Across the tested range, the Bures distance changes from to on shadow-16 records and from to on count-16 records. Because depolarization moves the target toward the maximally mixed state, we interpret these results as a state-mixedness stress test rather than evidence of general device-noise robustness. On the depolarized Greenberger–Horne–Zeilinger (GHZ) target at , BuresTomFlow obtains a Bures distance of , compared with for linear inversion. However, the present experiments do not model gate errors, readout errors, or decoherence during state preparation and measurement. We therefore do not claim robustness to those device-noise processes.
I thank the authors for their detailed response to the questions made on my review. They answered all of my concerns with detailed explanations. I am not a expert in the subject but will take this into consideration moving forward.
Best Regards
Thank you for taking the time to read our response and for your thoughtful feedback. Your comments helped us clarify the scope of our claims and improve the paper, and we sincerely appreciate your consideration.
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 4/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors construct a flow-matching sampler for amortized inference in the setting of quantum tomography. The geometry of the flow respects the natural geometry of quantum states. The authors show that this geometry-respecting flow (and their other contributions) lead to empirically more accurate inference, when evaluated on several reasonable metrics.
Strengths and weaknesses
Strengths
- Very interesting conceptually: it's impressive to see how a theoretically better geometry can lead to empirical gains in performance.
- Very clearly written and well-structured paper.
- Meaningful empirical results, decreasing error by a factor of about 2.
Weaknesses
- The presentation of the results could use some work (see comments below).
Questions
- The paper presents strong empirical results that respecting the Bures-Wasserstein geometry improves upon Euclidean flows. However, it's not clear that the projection of geodesic in the positive cone is a geodesic in the trace-one subspace. In fact, if I'm follwing Section 5 of https://arxiv.org/abs/2001.08056 correctly, this is not the case. I wonder if you have considered this, i.e. is it possible to construct a flow only in the trace-one subspace with geodesics from the induced metric?
- The conclusion is short and could use expanding, especially the limitations. I can't think of a specific limitation that needs addressing, but I'm sure there must be more to say there.
- For the "Observables" metric, you should mention 1) what percentage of observables are held out 2) if the holdouts are selected at random (I assume they are).
- The titles of the subplots in Figure 2 should change to match the columns in Table 1, for clarity --- this would also entail replacing "Coverage" by "Coverage Error." Also, I have no idea what "Runtime quality" means here: is this Bures distance averaged over all regimes? Or something else? Finally (this is a small quibble), I would suggest removing the blue/green/yellow colors from subplot (b), as they don't provide any additional information and overlap with a different use of color in subplot (c).
Limitations
yes
Final justification
I have read the other reviewers' comments and the authors' responses. I found Reviewer iy9o's criticisms particularly strong, and if the authors did not address them I might have lowered my score. However, I found the authors' responses to Reviewer iy9o (in particular, their direct posterior-posterior checks and their updated discussion of coverage) sufficient to address these concerns. Therefore I will retain my positive score.
Formatting concerns
None.
1 comment
Rebuttal
Response to Reviewer
We thank the reviewer for the careful and constructive comments.
1. Geometry of the normalized trace-one path
Reviewer concern. The paper presents strong empirical results that respecting the Bures-Wasserstein geometry improves upon Euclidean flows. However, it's not clear that the projection of geodesic in the positive cone is a geodesic in the trace-one subspace. In fact, if I'm follwing Section 5 of Bures–Wasserstein geometry for positive-definite Hermitian matrices and their trace-one subset correctly, this is not the case. I wonder if you have considered this, i.e. is it possible to construct a flow only in the trace-one subspace with geodesics from the induced metric?
Response.
The reviewer is correct that a generic projection onto the trace-one set need not preserve geodesics. Our construction uses a more specific radially normalized path of optimally aligned factors, as clarified below. Specifically, let be the BW transport map from to the smoothed target , and let and . Since , these factors are optimally aligned. Across the 19,200 evaluated supervised path states, the numerical eigenvalue floor activated in 0 cases; the minimum pre-projection eigenvalue was , compared with the implemented floor . Thus, at every evaluated supervised path state, the projection reduced to trace normalization:
The resulting path remains in the trace-one manifold and traces the induced-metric geodesic of Theorem 7 in [33], with a non-constant-speed parameterization.
The chord parameter is not generally constant speed in the Bures–Wasserstein angle; a constant-speed parameterization is obtained by spherical interpolation of the aligned factors. Flow Matching permits this differentiable parameterization [10,21]. The reported Bures distance and the induced Riemannian distance satisfy [33]:
The experiments report , whereas is the induced Riemannian distance.
This clarification does not change the implemented supervised path or the underlying experimental results.
We will revise Sections 2.4 and 3.3 and Appendix B to state these distinctions explicitly.
2. Conclusion and limitations
Reviewer concern. The conclusion is short and could use expanding, especially the limitations. I can't think of a specific limitation that needs addressing, but I'm sure there must be more to say there.
Response.
We will expand the conclusion to state that the current end-to-end posterior-tomography evidence is limited to full-rank dense four-qubit simulations with ideal product-Pauli measurements. Rank-deficient states, end-to-end posterior tomography at larger Hilbert-space dimensions, device noise or drift, adaptive protocols, and experimental records are not evaluated.
3. Observable holdout protocol
Reviewer concern. For the "Observables" metric, you should mention 1) what percentage of observables are held out 2) if the holdouts are selected at random (I assume they are).
Response.
The evaluation observables were sampled uniformly without replacement from the non-identity four-qubit Pauli strings before model comparison and were then fixed across all methods, regimes, and seeds. They represent of this set and we will state this explicitly.
4. Figure 2 presentation and runtime definition
Reviewer concern. The titles of the subplots in Figure 2 should change to match the columns in Table 1, for clarity --- this would also entail replacing "Coverage" by "Coverage Error." Also, I have no idea what "Runtime quality" means here: is this Bures distance averaged over all regimes? Or something else? Finally (this is a small quibble), I would suggest removing the blue/green/yellow colors from subplot (b), as they don't provide any additional information and overlap with a different use of color in subplot (c).
Response.
We will rename the lower panels as (A) Bures distance, (B) Coverage error, (C) Observable error, and (D) Bures distance versus runtime, with panel (B) reporting the same coverage-error quantity as Table 1.
In panel (D), each point plots the mean Bures distance against the mean training-plus-posterior-generation wall-clock time for the corresponding learned-sampler row of Table 1. The aggregation uses the eight calibrated regimes and five seeds per regime, with the two log-density variants merged as in Table 1. We will regenerate panel (D) directly from these summaries. We will revise Section 4 and the runtime appendix to distinguish this total-runtime metric from the separate post-training amortized-query diagnostic and state both definitions explicitly.
We will use a single neutral color for the three entries in the top-right subplot (b).
- Rating
- 3/6
- Confidence
- 2/5
- Quality
- 2/4
- Clarity
- 3/4
- Significance
- 2/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper studies finite-shot quantum state tomography as an amortized Bayesian inference problem. Instead of returning a single reconstructed density matrix, the proposed method (BuresTomFlow) trains a measurement-conditioned flow matching model that outputs posterior samples over 4-qubit density matrices. Training pairs are generated by prior-predictive simulation (thermal states of a transverse-field Ising family, product-Pauli count/shadow/mixed records). The methodological ingredients are: (i) probability paths given by Bures-Wasserstein transport on the positive cone followed by eigenvalue-clamped projection to the trace-one set, (ii) a velocity-matching loss in the local Bures tangent metric defined via a Lyapunov equation, and (iii) a shot-weighted endpoint-consistency term. Experiments compare against Cholesky, log-density/mirror charts, vanilla Riemannian flow matching, and linear inversion, reporting Bures distance of the posterior center, credible-ball coverage error, held-out observable error, and runtime, with claimed improvements on all posterior metrics.
Strengths and weaknesses
The problem framing is sensible and timely. Casting tomography as simulation-based inference with a conditional flow matching sampler is a natural but, to my knowledge, not previously executed combination, and the prior-predictive justification for why the trained conditional law matches the Bayesian posterior is stated correctly. The geometric construction is coherent and clearly written: the paper is honest that the trace-one set is not a geodesic submanifold of the BW cone and treats the projection as part of the modeled path, and the Lyapunov-based tangent metric connects the training loss to the evaluation distance in a principled way. The control-experiment design (Cholesky coordinates, log-density charts, generic Riemannian FM, point estimation) is thoughtful and, in principle, isolates the role of the Bures-specific path and metric. Appendices A–D are unusually detailed about the measurement simulator and evaluation protocol.
Unfortunately, the empirical evidence does not currently support the paper's central claim of calibrated posterior uncertainty, and several reported statistics suggest degenerate behavior rather than genuine calibration.
First, the coverage numbers appear degenerate. Coverage error is defined as |Cov − α| with α = 0.9. BuresTomFlow reports 0.1000 ± 0.0000 across 40 runs, which is only consistent with empirical coverage being exactly 1.0 (or exactly 0.8) in every single run; zero variance across 40 runs strongly suggests Cov ≡ 1.0, i.e., credible balls that always contain the truth. That is systematic overcoverage, not calibration, yet it is presented as the best calibration result. Symmetrically, the log-density controls report 0.9000 ± 0.0000, i.e., coverage exactly 0 in every run. Raw coverage values are never reported, and the post-hoc radius-scale search s* on a calibration split (Eq. 35) makes it even harder to interpret what remains of the "calibration" claim.
Second, the rank-calibration diagnostic contradicts the headline claim rather than supporting it. In Table 5, all methods, including BuresTomFlow, report 10-bin rank ECE ≈ 0.1800 — which is exactly the value obtained when all rank statistics fall into a single bin — and ACLD ≈ 0.471 with essentially zero variance. In other words, every method's posterior is maximally non-uniform under this diagnostic, and the proposed method differs from the controls only in the fourth decimal place. The main text's statement that the rank check "gives the same ordering as the main calibration comparison" is technically true but materially misleading: the diagnostic indicates that none of the posteriors, including the proposed one, is calibrated in the rank sense.
Third, the training and evaluation budget is too small to support comparative conclusions. All learned samplers are trained for 420 Adam steps at batch size 8 (~3,400 simulated pairs) and integrated with 4 Euler steps (Δt = 0.25). At this budget, differences between parameterizations plausibly reflect optimization ease rather than converged posterior quality. No learning curves, convergence checks, solver-step ablations, or per-baseline hyperparameter tuning protocols are provided, so baseline fairness cannot be assessed.
Fourth, there is no comparison to a ground-truth posterior. For 4 qubits with a 3-parameter (J, h, β) prior, a well-tuned MCMC/SMC posterior is computationally feasible and would provide the missing reference: without it, all reported quantities (distance of the posterior center to ρ*, coverage of the truth) are indirect proxies that cannot distinguish an accurate posterior from, e.g., a diffuse cloud centered at a good point estimate. Relatedly, the prior is very restrictive — targets effectively live near a 3-dimensional family plus an identity floor — so the task is far easier than generic tomography, and no out-of-prior generalization is tested.
Finally, several presentation issues reduce trust in the results: the introduction claims gains are "clearest in low-shot regimes," but Figure 2 shows a nearly uniform ~28% Bures-distance reduction across all shot budgets from 4 to 128, and the expanded grid in Table 4 extends this pattern to 256 shots (e.g., count-256: 0.260, shadow-256: 0.279), with no visible low-shot advantage; Tables 3 and 4 reuse identical regime labels (e.g., shadow-128) with different numbers and only a vague explanation; the 236 ± 149 s "runtime" is never decomposed (training vs. sampling), making the cost comparison uninformative; and several implementation constants (base distribution p₀, λ, w_max, n_ref, p, the eigenvalue floors, N held-out tasks, the scale grid S) are unspecified, as is how the derivative of the eigenvalue-clamped projection is computed at eigenvalue crossings.
In summary: the modeling idea is attractive and the write-up of the geometry is good, but the quantitative evidence for the paper's core claim — calibrated posterior sampling — appears to be an artifact of degenerate coverage/rank statistics, and the experimental scale (one narrow synthetic family, 420 training steps, no ground-truth posterior) is insufficient for a NeurIPS-level empirical claim.
Questions
-
Report raw empirical coverage Cov (not |Cov − α|) per method and per regime, before and after the s* rescaling. Is BuresTomFlow's coverage exactly 1.0 in all 40 runs? If so, please justify describing systematic overcoverage as the best-calibrated result. This is the single most important point for my evaluation.
-
Explain Table 5. ECE₁₀ = 0.18 corresponds to all rank statistics falling in one bin; ACLD ≈ 0.471 with zero variance likewise indicates a degenerate rank distribution for every method. Please show the actual rank histograms and reconcile this with the claim of calibrated posteriors; a standard SBC analysis (Talts et al.) over scalar functionals of ρ would be more convincing than the anchor-ball construction.
-
Provide convergence evidence: learning curves, results at substantially larger step counts (e.g., ≥10k steps) and finer ODE integration, and describe how baseline hyperparameters were tuned. Do the reported gaps persist at convergence?
-
On a subset of records, compare all samplers to a ground-truth posterior obtained by MCMC/SMC over the (J, h, β) parameterization (feasible at 4 qubits), reporting a posterior-to-posterior discrepancy rather than only truth-centered proxies.
-
Evaluate on target states outside the TFIM thermal prior (e.g., depolarized random pure states, noisy GHZ) to probe amortization robustness, and reconcile the "gains clearest in low-shot regimes" claim with the nearly budget-independent reductions in Figure 2.
Limitations
Appendix H candidly discusses the 4-qubit scope and the ideal measurement model, which is appreciated. However, the restrictiveness of the 3-parameter thermal prior, the degenerate behavior of the calibration diagnostics, and the very small optimization budget are not acknowledged as limitations and should be.
Formatting concerns
No major formatting or anonymity violations noted.
9 comments
Rebuttal
We thank the reviewer for these detailed questions. The remaining targeted experiments and diagnostics are currently in progress, and we will post the complete results in this thread as soon as they are available during the discussion period.
Rebuttal for Reviewer iy9o — Part 1/7
Response to Reviewer [iy9o]
We sincerely thank the reviewer for the careful and technically detailed assessment. The review prompted us to audit the submitted coverage and rank diagnostics and to rerun the geometry comparison under a substantially larger shared training protocol.
All numbered citations refer to the bibliography of the submitted manuscript. The additional references introduced in this response are labeled [R1–R2] and listed at the end.
W1/Q1 — Coverage reporting and interpretation.
Our audit confirms that the submitted coverage error of corresponds to raw coverage in all 40 runs. The scalar values are numerically correct, but the unsigned summary obscures the direction of miscoverage. We therefore report signed coverage directly:
| Method | Raw | after the submitted procedure |
|---|---|---|
| BuresTomFlow | (40/40) | |
| Cholesky geometry | ||
| Log-density chart controls | (0/80) | |
| Vanilla RFM |
The log-density row combines the Log-Euclidean control and the mirror-chart control with a Frobenius loss. Each was evaluated in 40 runs. Both had zero raw coverage and zero post- coverage in every run.
The submitted scalar is therefore an incomplete coverage summary rather than a stand-alone calibration certificate. We consequently reran the geometry comparison under a stronger and uniform protocol: 2,000 updates, batch size 32, and five independent seeds, with coverage evaluated on 96 held-out states independent of both the training stream and the disjoint calibration split. Across the completed cells of the shared grid, BuresTomFlow has the lowest posterior-center Bures distance () and held-out observable error () among the tested geometry controls. Its raw coverage averages across regimes and increases to after selecting exclusively on the disjoint calibration split and fixing it before evaluation on the untouched test split. The regime-level results are:
| Regime | Raw | after | Mean |
|---|---|---|---|
| count-32 | |||
| mixed-32 | |||
| count-8 | |||
| shadow-32 | |||
| mixed-4 | |||
| shadow-16 | |||
| shadow-4 |
The grid-based adjustment produces near-nominal held-out coverage in the most informative count-32 and mixed-32 regimes, but it remains substantially below nominal in the sparse-shadow regimes, where also reaches the upper boundary of the submitted grid . We therefore report these values as a transparent coverage diagnostic and do not use the results as evidence that the learned posterior distribution is calibrated.
We additionally replace the grid search with an independent split-conformal construction [R1]. For calibration task , let denote the true density matrix and the method's posterior-center estimate; the nonconformity score is the Bures center-to-truth distance . The finite-sample quantile of these scores on the disjoint calibration split is fixed before test evaluation and defines a Bures ball around the test-time posterior center. Under the prior-predictive exchangeability assumption, this construction provides finite-sample marginal coverage. It is a conformalized posterior-center prediction region. Its radius is calibrated from center-to-truth scores rather than from the spread of the learned posterior samples, and its guarantee concerns set coverage rather than distributional calibration.
Rebuttal for Reviewer iy9o — Part 2/7
| Method | Conformal coverage at nominal | Mean Bures radius |
|---|---|---|
| BuresTomFlow | ||
| Vanilla RFM | ||
| Log-Euclidean | ||
| Cholesky |
Across the evaluation, all four methods attain comparable empirical coverage near the nominal level, while BuresTomFlow has the smallest mean Bures radius. This establishes a substantive and precisely scoped result: BuresTomFlow improves posterior-center and observable accuracy under the shared protocol, while its split-conformal posterior-center regions attain marginal coverage with smaller sets than the tested geometry controls. We will revise Table 1 and Figure 2 to report signed raw coverage, regime-specific pre- and post-adjustment values, and this split-conformal coverage-radius comparison.
W2/Q2 — Rank diagnostics and simulation-based calibration.
We first clarify the scope of the submitted calibration claim. The submission did not claim exact posterior recovery or that BuresTomFlow passes standard simulation-based calibration (SBC). However, we agree that broad phrases such as “calibrated posterior uncertainty” could reasonably be read as making a stronger distributional-calibration claim than the submitted coverage and rank diagnostics directly established. We therefore revise this wording and explicitly distinguish two separate properties: prior-predictive SBC of the learned posterior samples and split-conformal marginal coverage of posterior-center prediction regions. The submitted anchor-ball rank statistics are non-uniform and do not support the broader distributional-calibration wording. We therefore remove Table 5 and its fourth-decimal ordering, and replace the pooled anchor-ball diagnostic with standard SBC [28] on fixed scalar functionals. For this SBC analysis, we used 63 posterior samples per task, which gives ranks from 0 to 63. The submitted coverage evaluation used 32 samples per task. For BuresTomFlow, we evaluated 200 prior-predictive tasks in each of the count-8 and count-32 scenarios using six fixed functionals: four Pauli expectations, purity, and the largest eigenvalue. The resulting ranks remain significantly non-uniform. Representative results are:
| Scenario and functional | Rank mean std. | -value | 20-bin ECE |
|---|---|---|---|
| count-8, Pauli | |||
| count-8, purity | |||
| count-32, Pauli | |||
| count-32, purity |
For count-32 and the Pauli functional, the observed counts in the 20 rank bins are . In particular, 175 of the 200 ranks fall in four adjacent bins, directly showing substantial deviation from the uniform rank distribution expected under SBC. We will include the complete histograms for all six functionals in both count regimes in the revision.
These results show that, for the evaluated functionals in the count-8 and count-32 scenarios, the observed BuresTomFlow rank distributions are inconsistent with the discrete uniformity expected under the tested prior-predictive SBC protocol. This finding does not negate the separate split-conformal guarantee, which concerns marginal coverage of conformalized posterior-center regions under the stated prior-predictive exchangeability assumption rather than distributional calibration of the learned posterior sample cloud. We will revise the manuscript throughout to distinguish the supported claims: BuresTomFlow improves posterior-center accuracy and held-out observable prediction under the structured four-qubit TFIM prior; the reference-posterior experiments show the lowest tested Bures-ground sample discrepancy, with clearly resolved reductions in mixed-4 and mixed-16; and split-conformal Bures regions provide a separate finite-sample marginal-coverage guarantee rather than posterior-distribution calibration.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Thank you for the encouraging assessment and for highlighting the main issues to focus on. We address the geometric construction and presentation questions in our response to Reviewer L9B3, and the scalability and additional tomography baselines in our response to Reviewer 7niR. On noise, the responses to Reviewers 7niR and iy9o report state-level depolarization tests, evaluations on out-of-prior targets, and retraining with depolarization included in the prior. We will incorporate these clarifications, results, and limitations in the revision.