Abstract. Contrastive vision-language (VL) pretraining in computational pathology has generally relied on curated image-caption datasets sourced from social media, educational videos, and research publications. These corpora are sparse relative to the diversity of tissue morphology and difficult to scale further, as pathologists do not routinely produce descriptive captions in clinical practice. We propose to instead leverage slide-level pathology reports which can be generated during routine diagnostic workflows in a scalable manner. A key challenge in this weakly-supervised setting is that pathology reports describe macroscopic, diagnostic findings while patch-level visual features describe microscopic findings. We introduce Locked Image Multiple Instance PreTraining (LIMIT), which addresses this gap by freezing a pretrained vision encoder and fine-tuning only the text encoder: report embeddings serve as cross-attention queries over bags of patch features, producing report-conditioned slide representations optimized via InfoNCE. Using LIMIT, we establish CONCH-Z, which aligns the text encoder of CONCH v1.5 to 335k clinical reports. Evaluated across 22 tasks spanning patch-level classification, tumor detection, and slide-level subtyping, CONCH-Z establishes state-of-the-art zero-shot performance over VL encoders trained on curated caption datasets, while simultaneously closing the gap with slide-level foundation models trained with substantially more parameters and compute. The code and model is available at https://github.com/mahmoodlab/LIMIT.

From the authors: Daniel Shao · edit · also an author?

Nothing yet.

How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
4 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (spotlight)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (spotlight) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:48 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (spotlight)
Read decision
Meta-review

While reviewers agreed that the paper addresses a practically important problem with a clear, well-written pipeline that effectively leverages slide-level reports for pathology vision-language alignment, they also raised serious concerns about the paper's soundness and significance: (1) the method is validated exclusively on CONCH-1.5, leaving open whether the gains generalize to other foundation models or stem from interaction with a specific pretrained representation; (2) the private pretraining dataset lacks sufficient characterization, raising concerns about reproducibility and the true "zero-shot" nature of evaluations due to potential concept overlap; (3) the frozen vision encoder design limits learning of unseen concepts, and critical ablations—such as fine-tuning the vision side or training from scratch—are missing to justify this constraint. Addressing these would require multi-backbone validation, transparent dataset statistics, and ablation on encoder adaptability.

Final justification

Reviewers raised scores after rebuttal. Since all reviews are positive, I maintain my recommendation of acceptance.

Area Chair PJgJ · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

While reviewers agreed that the paper addresses a practically important problem with a clear, well-written pipeline that effectively leverages slide-level reports for pathology vision-language alignment, they also raised serious concerns about the paper's soundness and significance: (1) the method is validated exclusively on CONCH-1.5, leaving open whether the gains generalize to other foundation models or stem from interaction with a specific pretrained representation; (2) the private pretraining dataset lacks sufficient characterization, raising concerns about reproducibility and the true "zero-shot" nature of evaluations due to potential concept overlap; (3) the frozen vision encoder design limits learning of unseen concepts, and critical ablations—such as fine-tuning the vision side or training from scratch—are missing to justify this constraint. Addressing these would require multi-backbone validation, transparent dataset statistics, and ablation on encoder adaptability.

Final justification

Reviewers raised scores after rebuttal. Since all reviews are positive, I maintain my recommendation of acceptance.

2 comments
Authors · CommentOpenReview ↗

Summary response

We thank the reviewers and the Area Chair for their careful and constructive assessment. We are encouraged that the reviewers recognized the paper as clear, well written, practically motivated, and supported by broad empirical evaluation across patch-level classification, tumor detection, and slide-level classification. Reviewers also highlighted the value of using naturally available slide-level pathology reports as supervision, the intuitive report-conditioned aggregation mechanism, and the comparison against both zero-shot VLMs and supervised MIL baselines.

The main three concerns raised by the metareview are addressed below. In brief, we added multi-backbone experiments, dataset and zero-shot overlap analyses, report-normalization analyses, and ablations motivating the locked-image design.


1. LIMIT generalizes across backbones

(1) The method is validated exclusively on CONCH-1.5, leaving open whether the gains generalize to other foundation models or stem from interaction with a specific pretrained representation

We trained three additional pathology VLM backbones with LIMIT using a randomly-selected 25k pretraining subset, finding LIMIT consistently improves performance across all models and datasets (mcJX-A1).

Shown below is average change in balanced accuracy after LIMIT fine-tuning.

Model SPIDER-C SPIDER-F CATCH-C CATCH-F HistAI TCGA-OT46
PLIP +3.08 +3.16 +2.50 +1.30 +4.57 +3.85
Quilt +2.27 +1.54 +4.00 +6.60 +4.90 +2.92
MUSK +3.17 +2.19 +1.80 +5.60 +4.20 +4.15

Furthermore, these gains are non-specific to our internal dataset. LIMIT improves CONCH-1.5 by +6.8+6.8% when pretrained on the publicly available TCGA (hKSf-A7.2).


2. Concept overlap does not drive performance gain

(2) the private pretraining dataset lacks sufficient characterization, raising concerns about reproducibility and the true "zero-shot" nature of evaluations due to potential concept overlap

Dataset Description: We have characterized the pretraining dataset with all requested details including scanner distribution, resolution, and report content (hKSf A2-3)

Concept overlap: We examined the overlap between pretraining text and downstream labels, finding that (1) Concept overlap was low; the number of reports which did not mention a task's diagnostic label ranged from 90.3% for TCGA-OT46 to 99.4% for HistAI. (2) Performance gains are not driven by concept frequency. Spearman correlation revealed that performance gains were not correlated with the concept frequency, demonstrating that performance improvements are driven by robust vision-language alignment rather than mere concept exposure. (baLs-A2).

Task Reports w/o diagnostic label (%) Spearman ρ\rho (exposure vs. gain) pp-value
CATCH 95.0 0.414 0.36
HistAI 99.3 0.543 0.21
SPIDER 95.6 -0.055 0.81
TCGA-OT46 90.3 0.066 0.72

3. Motivation behind Locked Image Tuning

(3) the frozen vision encoder design limits learning of unseen concepts, and critical ablations—such as fine-tuning the vision side or training from scratch—are missing to justify this constraint.

Fine-tuning the vision encoder is intractable Unfreezing the vision encoder would constitute end-to-end training: a prohibitively expensive approach due to the gigapixel size of WSIs. For instance, we show (baLs-A1) that training on 64 image patches requires nearly 60 GB of GPU memory and increases latency/sample by 31x compared to text-only training.

We examine whether this computational strain is warranted by training CONCH-1.5 with the vision encoder unfrozen using LIMIT-V, an adaption which only passes gradients through the top 64 query-relevant image patches. This vision-trainable variant took 41 hours to train on 25k samples and yielded comparable performance to the vision-frozen variant on the full SPIDER evaluation set (410,000 evaluation samples).

CONCH-1.5 w/ LIMIT w/ LIMIT-V
Spider-F 36.5 39.3 39.5
Spider-C 39.0 50.2 49.1

Training from scratch is unsuitable We also added ablations to test the role of finetuning the text encoder compared to training from scratch. A randomly initialized text encoder trained on 25k samples barely improved over a frozen random baseline, while using pretrained CONCH only for aggregation substantially improved performance. However, both remained well below CONCH-Z also trained only on 25k samples. The averaged performances are summarized below, with full results shown in mcJX-A2:

Rand Rand-train Rand-train (CONCH agg.) CONCH-Z@25k
SPIDER-F 6.6 12.5 23.3 39.3
SPIDER-C 16.3 22.6 37.2 50.2

These results show that LIMIT benefits from preexisting image-text alignment for report-conditioned patch selection, while still recovering substantial gains through text-side adaptation with a frozen image encoder.

Authors · CommentOpenReview ↗

Rebuttal Period Overview

As the author-discussion phase concludes, we would like to provide a brief overview of reviewer responses. All three reviewers unanimously recommend acceptance with a score of 5. Reviewer baLs maintained their positive score, while reviewers mcJX and hKSf raised their scores from 4 to 5, indicating that the main concerns from the metareview have been convincingly addressed. Specifically, hKSf found the rebuttal thoughtful and convincing, noting that the added quantitative results on public data and improved reproducibility further strengthened the manuscript. Similarly, mcJX highlighted the value of our new experiments demonstrating generalization across three additional foundation models.

We thank the reviewers and the Area Chair for their suggestions on expanded experiments, which demonstrate that LIMIT generalizes across foundation models and pretraining datasets. We believe LIMIT presents a robust, intuitive training paradigm for attributing global captions to local image regions. While our evaluation focuses on pathology, this problem of attribution is prevalent across the broader vision-language field (e.g., video, cell painting, remote sensing), positioning LIMIT to be of high interest to the general ML community.

Reviewer hKSfOpenReview ↗
Rating
5/6
Confidence
5/5
Quality
3/4
Clarity
4/4
Significance
3/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper proposes LIMIT, a strategy for adapting an existing pathology vision-language foundation model using large-scale slide-report pairs. Starting from a pretrained image-text embedding model (CONCH), the method keeps the image encoder frozen and further trains the text branch using contrastive alignment between slide-level pathology reports and image representations aggregated from patch embeddings via cross-modal attention. The proposed weighting of negative samples in the contrastive loss is based on text-embedding-similarity (within minibatch) and crucial for performance. The model is pretrained on an internal dataset containing more than 300k whole-slide image and pathology report pairs and is evaluated in a range of downstream tasks.

Strengths and weaknesses

Strengths

  • The paper presents a practically relevant strategy for improving pathology vision-language foundation models using large-scale slide-report data.
  • The proposed method outperforms all evaluated baselines across the reported experiments.
  • The manuscript is clearly written, well organized, and easy to follow.
  • The proposed negative weighting strategy is intuitive and appears to contribute substantially to the observed performance gains.
  • The work highlights the potential value of leveraging pathology reports as a source of supervision beyond sparse captions or labels.

Weaknesses

  • The pretraining dataset is not publicly available, which substantially limits reproducibility.
  • The description of the internal pretraining dataset is insufficient. Given that the dataset is a central component of the work, substantially more information should be provided both in the main manuscript and appendix (e.g., disease distribution, organ types, specimen types, report characteristics, image statistics, scanner information, resolutions, etc.).
  • The method is only evaluated using CONCH as the underlying foundation model. It remains unclear whether the proposed training strategy generalizes to other pathology vision-language encoders.
  • The planned code release appears limited. Given that the dataset cannot be released, complete training and evaluation code becomes even more important for reproducibility.
  • The novelty of the method is somewhat difficult to assess. Several individual components (cross-modal attention, contrastive image-text learning, freezing one modality during training, hard-negative weighting) are known ideas. The paper would benefit from a clearer discussion of what is fundamentally new compared to prior pathology and general multimodal learning approaches.
  • I am not fully convinced that the reported evaluations can always be considered truly "zero-shot". This depends strongly on the content of the internal pretraining dataset. If diseases, diagnoses, or report concepts closely resemble the downstream evaluation classes, the interpretation of the results changes substantially. This point is central to the paper and should be addressed more rigorously.
  • The proposed approach relies heavily on the representational capacity of the frozen image encoder. Consequently, concepts not encoded by the base model may be difficult or impossible to learn during adaptation. However, this limitation is already mentioned by the reviewers.
Questions

. The method is only evaluated using CONCH. Have the authors experimented with additional pathology foundation models or image encoders? Even a limited experiment on another pretrained backbone would help determine whether LIMIT is a generally applicable training strategy or primarily a CONCH-specific adaptation approach. Positive evidence here would strengthen my assessment. 2. How dependent is the success of LIMIT on the characteristics of the pre-training dataset? More specifically, which properties must a slide-report dataset satisfy for the method to work well? The method appears to assume that report content is sufficiently correlated with localized image regions represented by patches. A discussion of this assumption and potential failure cases would be valuable. 3. Negative weighting mechanism. The proposed weighting strategy relies on text-embedding similarity. How sensitive is this mechanism to the choice and quality of the initial text encoder? Have the authors investigated alternative similarity measures or different initialization strategies? Such analysis would improve understanding of why the weighting works. 4. Since the dataset cannot be released, I strongly encourage the authors to compensate through:

  • a substantially more detailed dataset description,
  • release of the complete training and evaluation code,
  • potentially an additional experiment using publicly available datasets for pretraining and evaluation (even if performance is lower). --> Such experiments would help assess reproducibility and practical feasibility outside the authors' institution.
  1. Zero-shot evaluation claim. I would appreciate a more rigorous analysis of the relationship between the internal pretraining dataset and downstream evaluation tasks. Specifically:
  • Are the evaluated diseases, diagnoses, or report concepts present in the pretraining data?
  • How much semantic overlap exists between pretraining reports and downstream class definitions?
  • Under what definition should the reported tasks be considered zero-shot? A convincing clarification here could positively affect my overall assessment.
  1. Clarification of the novelty and intuition. My current understanding is that the method combines: (i) image-text contrastive learning, (ii) cross-modal attention between report and patch representations, (iii) training only the text branch while keeping the image encoder frozen, and (iv) similarity-based hard-negative weighting. It would help if the authors more clearly explain which aspect is the key conceptual contribution and how it differs from prior multimodal pathology methods. In addition, what is the intuition behind conditioning patch representations on the slide report through the proposed attention mechanism?

  2. It is unclear how inference is performed when patch-level predictions are required. During training, patch embeddings are aggregated at the slide level. How should the model be interpreted or applied at patch level?

  3. In Table 3, a brief intuition for why the zero-shot methods outperform supervised methods would be helpful

Limitations

The paper discusses several limitations, but I believe some important aspects deserve additional attention:

  • The proposed training strategy is only evaluated using CONCH. Consequently, it remains unclear whether the approach generalizes across pathology foundation models and encoder architectures.
  • The internal pretraining dataset is not released. While this is understandable, the manuscript should provide substantially more information about the dataset composition and statistics.
  • The interpretation of the reported zero-shot evaluations depends strongly on the relationship between the internal pretraining data and downstream tasks. This limitation should be discussed more explicitly.
Final justification

The authors have addressed all of my comments in a convincing way and in high quality, which is why I changed my 'overall score' form 4 to 5.

Formatting concerns
7 comments
Authors · CommentOpenReview ↗

1/2


A1. Generalizability Beyond CONCH [Metareview W1]

W3,L1,Q1: A second-backbone experiment is needed to show LIMIT as a general training strategy.

Please see mcJX-A1, which shows notable gains across three new backbone models on a 25k training data subset.

A2. Dataset Transparency, Release & Reproducibility

W1, W2, L2: Provide more information on the pretraining dataset

We processed all internal reports using an LLM (Qwen3.6-35B-A3B-FP8) to categorize them into clinical groups. The dataset exhibits substantial acquisition diversity across multiple vendors and resolution scales, alongside rich text-side annotations. Per-organ distribution is shown in Figure A1.

Category Description Value
Report Class Malignant/Neoplastic 69.2%
Non-neoplastic 23.6%
Premalignant/Benign 4.1%
Unresolved 3.1%
Textual Statistics Unique organ strings 689
Unique normalized phrases 148,279
Scanners Leica 35.0%
Motic 32.3%
Philips 9.9%
3D Histech 9.1%
GTEx consortium 7.4%
Hamamatsu 6.2%
Roche/Zeiss <1%
Resolution 0.24-0.26µm/pixel 52.9%
0.49-0.52µm/pixel 39.9%
0.12-0.23µm/pixel 7.1%

We will also release the CONCH-Z checkpoint, model training code, prompt templates, and benchmark evaluation scripts.


A3. Rigor of "Zero-Shot" Claims & Dataset Overlap [MetaReview W2]

W6,L3,Q5: How much semantic overlap is there between pre-training and evaluation? Is this truly a zeroshot setting?

We thank the reviewer for this critical point. While we follow the field standard (e.g., CONCH, PLIP, PRISM) in defining zero-shot as zero exposure to the supervised task format and zero task-specific gradient updates, we fully acknowledge the inherent concept overlap in medical VLM pretraining. We agree that "zero-shot" claims become misleading if pretraining reports functionally mirror downstream tasks, particularly when semantic overlap is widespread and dominates the pretraining data.

We therefore quantified the report-level occurrence of downstream diagnostic labels across our internal pretraining corpus:

CATCH-F HistAI SPIDER-F TCGA-OT46
Reports w/o Diagnostic Match 95.0% 99.7% 95.6% 90.3%

Between 90.3% and 99.3% of our training reports make no mention of the target labels or their synonyms. Furthermore, our performance gains persist even on HistAI where lexical overlap is nearly nonexistent.

Crucially, lexical exposure does not drive our performance gains (W6). A Spearman rank correlation confirms no significant association between diagnostic exposure frequency (categorized as no/weak/moderate exposure classes) and per-class performance gain:

Spearman's ρ\rho pp-value
CATCH 0.414 0.36
HistAI 0.54 0.21
SPIDER -0.05 0.81
TCGA-OT46 0.07 0.72

Per L3, we will add a dedicated section in the revision documenting these exact exposure metrics to transparently frame the limitations of zero-shot interpretation.

A4. Novelty & Component Intuition

W5, Q6.1: Clarify which aspect is the key conceptual contribution and how it differs from prior multimodal pathology methods

Our primary conceptual contribution is demonstrating how to effectively train patch-level vision-language models using routine, abundant slide-level reports instead of scarce, hand-crafted patch-level captions.

While prior multimodal pathology models rely on patch captions sourced from PubMed, textbooks, or social media, (data sources that are both hard to scale and largely exhausted), our approach leverages slide-level reports, a naturally abundant and rapidly growing data source generated during routine clinical practice.

Unlike previous pathology methods that train patch encoders end-to-end using slide-level supervision, we show that LiT is an effective yet overlooked mechanism for aligning patch-level features with slide-level text.

Though the individual components are simple, naïve contrastive baselines fail in this setting (e.g., standard InfoNCE, Table 4). Our contribution lies in diagnosing why these standard approaches fail when connecting fine-grained image patches to global slide reports, and identifying an intuitive combination of components to address the pitfalls of LiT with slide reports.

Q6.2 What is the intuition behind conditioning patch representations on the slide report?

The intuition behind our attention mechanism comes from the context-dependent nature of whole-slide images. A report detailing squamous cell carcinoma focuses on the epithelium, whereas one for adenocarcinoma focuses on glands. By conditioning patch representations on the slide report, the attention mechanism guides the text to query the relevant morphological regions. This helps supervise the model by teaching it where to look to ground the overall clinical text in the local visual space. We will update the methods to more clearly discuss these details.

Authors · CommentOpenReview ↗

2/2

A5. Dataset Characteristics & Frozen Encoder Capacity

W7: LIMIT depends on the frozen image encoder, so concepts absent from the base visual representation may not be learnable through text-side adaptation alone.

We agree that LIMIT relies on the representational capacity of the frozen image encoder. However, a key finding of our study is that even with a frozen image encoder, substantial zero-shot performance gains can be achieved solely by updating the text encoder. The scale and consistency of these improvements are surprising and suggest that standard pretraining under-optimizes the text encoder, which may act as a critical bottleneck.

Furthermore, unfreezing the visual encoder requires end-to-end training, which is rarely adopted in the CPath community due to prohibitive computational costs. Nevertheless, we adapted LIMIT to support an unfrozen image encoder (mcJX-A2). This yielded comparable performance improvements to text-only training despite markedly increased computational demands, reinforcing the practical utility of our approach.

Q2.1: What properties must a slide-report pretraining dataset have for LIMIT to work well?

A useful slide-report dataset for LIMIT training should have:

  • Morphology-rich text: reports should retain diagnostic morphology rather than collapse to generic labels such as “tumor.”
  • Visual grounding: key report phrases should correspond to at least some visually identifiable patches.
  • Clinically meaningful negatives: negative reports should come from hard comparison sets, such as the same organ, to encourage fine-grained alignment.
  • A strong base image encoder: the frozen encoder must already capture the relevant histologic features well enough for text-side adaptation to align to them.

Q2.2: How valid is the assumption that report concepts align with localized patch-level visual evidence, and what are the likely failure cases?

We argue this assumption is highly valid for a broad class of diagnostic tasks. Many standard clinical evaluations (e.g tumor detection, cancer subtyping, micrometastases detection) operate on this exact localized premise: if there is any distinct region presenting a specific morphology (such as malignant cells), the entire slide inherits that label. For these tasks, slide-level report concepts naturally and reliably align with localized patch-level visual evidence.

However, because LIMIT relies on a weighted average for text-conditioned aggregation, this does introduce specific architectural limitations and failure cases for tasks that deviate from this paradigm:

Complex slide-level reasoning: Tasks such as Gleason grading require synthesizing multiple architectural patterns and spatial context, which may be lost in weighted-average pooling. Non-morphological targets: Survival prediction, temporal reasoning, IHC prediction from H&E Encoder blind spots: Because LIMIT is a locked-image method, if the frozen vision encoder does not encode a morphology, text tuning cannot create that missing visual signal.

We will add this discussion regarding both the validity of our assumption and its boundaries to the limitations section.


A6. Negative Weighting & Text Encoder Sensitivity

Q3: How sensitive is negative weighting to the choice and quality of the initial text encoder?

We thank the reviewer for their suggestion: we show in response to mcJX-A1 that LIMIT gains indeed extend to other models with varying text encoder quality (e.g MUSK, Quilt, PLIP).

A7. Public dataset retraining

Q4: Potentially an additional experiment using publicly available datasets for pretraining and evaluation (even if performance is lower).

We thank the reviewer for their suggestion. We will look into additional experiments using a public dataset. We note that an important motivation of private pretraining data is that the resulting model model can serve as an uncontaminated community resource, ensuring zero data leakage when evaluated on public benchmarks like TCGA.

A8. Patch-Level Inference

Q7: How should the model be applied at patch level?

We follow the standard zero-shot approach for patch-level prediction: we compute the direct cosine similarity between its frozen visual embedding and the candidate text embeddings from the LIMIT-adapted text encoder and select the argmax. We will clarify this mechanism in the revised manuscript.


A9. Supervised vs. Zero-Shot Baselines

Q8: In Table 3, a brief intuition for why the zero-shot methods outperform supervised methods would be helpful.

Please see our response to mcJX-A3.


We thank the reviewer for their thoughtful feedback, which has helped improved the reproducibility and rigor of our work. Please let us know if there are any additional questions or if our answers satisfy your concerns.

Reviewer hKSf · CommentOpenReview ↗

I thank the authors for the thoughtful and convincing response to all my points in such a short time. One question regarding A7 ("We will look into additional experiments using a public dataset."): What does this mean? will you provide additional experiments/results during this discussion phase?

Reviewer mcJXOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes fine-tuning pre-trained pathology vision-language foundation models using only slide-level reports. To this end, the authors propose to train the text encoder of CLIP-based pathology VLMs to align the report embedding from the text encoder with a report-specific slide-level pooled embedding obtained through a cross-attention mechanism, as the visual representation is initially tile-based. Such a contrastive training requires mining negative samples. The authors propose to sample negative reports coming from the same organ as the positive report and weight the importance of each negative report based on its cosine similarity (in the text encoder embedding space) with the positive report. The introduced method is evaluated on zero-shot tile-level and slide-level classification tasks and is compared against a large set of zero-shot, VLM, and supervised baselines.

Strengths and weaknesses

Strengths:

  • S1: Proposing a way to leverage largely available slide-level reports to improve pathology text encoders is very valuable for the community.
  • S2: The paper is well-written and easy to follow.
  • S3: The conducted empirical evaluation covers diverse tasks, datasets, and concurrent baselines.

Weaknesses:

  • W1. [Major] Proposed method only validated on a single foundation model: The introduced contrastive pre-training from slide-level reports is only empirically validated on the CONCH1.5 backbone. Showing the same improvement on at least a second pre-trained VLM would strengthen the claims of this paper by validating that the observed gains are not specific to the targeted CONCH1.5.
  • W2. [Major] Can we train a new model from scratch with the introduced pre-training?: The proposed method could be applied to pre-train a VLM from scratch, i.e., training both randomly-initialised vision and language encoders from slide-level reports only. Why have authors only considered text encoder fine-tuning? More insights should be provided about this choice, and an experiment trying to train from scratch could be appreciated, despite not being mandatory.
  • W3. [Major] Low performance of supervised baselines in Table 3: how do the authors explain the relatively low performance of supervised methods vs zero-shot ones in Table 3? For instance, CONCH-Zlin performs lower than CONCH-Z, which is surprising. Adding linear projectors should increase performance.
  • W4. [Minor] Higher variance in the synonym evaluation: Performance is indeed stronger on average than other methods over different synonyms. However, the variance appears to be higher as well (in particular on Skin and Thorax), which might contradict the claim of a better robustness to changes in text. Could the authors elaborate more on this?
Questions

The following questions are related to the listed weaknesses:

  • Q1 (W1): Can the authors show the same improvement on at least a second pre-trained VLM when applying their fine-tuning technique?
  • Q2 (W2): Why have authors only considered text encoder fine-tuning? More insights should be provided about this choice, and an experiment trying to train from scratch could be appreciated, despite not being mandatory.
  • Q3 (W3): How do the authors explain the relatively low performance of supervised methods vs zero-shot ones in Table 3?
  • Q4 (W4): The variance of CONCH-Z performance over different synonyms appears to be higher than that of other models (in particular on Skin and Thorax), which might contradict the claim of a better robustness to changes in text. Could the authors elaborate more on this?
Limitations

yes

Final justification

I have read the answers to my concerns but also to the ones raised by the other reviewers. Overall, the authors have clarified most of them, and have provided additional results that allow to better support their claims. In particular, the conducted experiments on 3 other foundation models are a great addition to this paper, supporting the generalizability of the claims. For these reasons, I have increased my score to "Accept".

Formatting concerns

No paper formatting concern.

5 comments
Authors · CommentOpenReview ↗

1/2

We are happy to hear the reviewer found our study on bridging text and slide encoders valuable and innovative.


A1. Generalizability Beyond CONCH [Metareview W1]

W1,Q1: Can the method’s gains be reproduced on a second pretrained VLM, or are they specific to CONCHv1.5?

Thank you for your important question for characterizing the generalizability of LIMIT.

To test whether the method is CONCH-specific, we applied the same LIMIT procedure to PLIP, Quilt, and MUSK on a randomly-selected 25k pretraining subset. All three models reliably improved across the 17 total evaluated tasks. Shown below is change in balanced accuracy after finetuning for SPIDER C/F and CATCH C/F patch-level classification, and HistAI, TCGA-OT46 slide-level classification. Negatives shown in bold.

Dataset Task PLIP Quilt MUSK Avg Δ\Delta
Spider-C Breast +3.96 +4.31 +5.19 +4.49
Spider-C Colorectal +0.17 +1.94 +3.31 +1.81
Spider-C Thorax +6.81 +2.33 +3.92 +4.35
Spider-C Skin +1.38 +0.5 +0.24 +0.71
Spider-F Breast +4.13 +1.79 +1.5 +2.47
Spider-F Colorectal +2.86 +3.72 +2.4 +2.99
Spider-F Thorax +1.22 -1.32 +4.33 +1.41
Spider-F Skin +4.42 +1.96 +0.51 +2.3
CATCH-C Skin +2.5 +4 +1.8 +2.77
CATCH-F Skin +1.3 +6.6 +5.6 +4.5
HistAI Breast +7.3 +5.2 +3.1 +5.2
HistAI Colorectal +3.6 +4.7 +8.4 +5.57
HistAI Skin +2.8 +4.8 +1.1 +2.9
TCGA-OT46 Breast +1 +4.5 +4.3 +3.27
TCGA-OT46 Lung +7.1 -0.3 +6.8 +4.53
TCGA-OT46 Brain +2.7 +4.8 +1.3 +2.93
TCGA-OT46 Other +4.6 +2.7 +4.2 +3.83

A2. Ablations on Vision Encoders & Locked-Image Tuning [MetaReview W3]

W2,Q2: Why fine-tune only the text encoder, and would training from scratch or a less constrained training setup work?

We thank the reviewer for highlighting this. We opted for text-encoder fine-tuning (LiT) over joint-training or training from scratch for two primary reasons:

  1. Why fine-tune only the text encoder? Vision encoder unfreezing is computationally intractable: unfreezing the vision encoder would constitute end-to-end joint training, which would require storing ViT activations across millions of pixels per slide. We show the immense computational costs of such end-to-end training in baLs-A1, in which training on just 64 patches per slide requires 60 GB of VRAM. In addition, baLs-A1 shows LIMIT with vision finetuning as requested by this reviewer. We thank the reviewer for highlighting the importance of discussing the challenges with joint end-to-end training to better motivate our work.
  2. Would training from scratch work?: We do not believe LIMIT is well-suited for training an encoder from scratch. LIMIT's core aggregation step capitalizes on a pretrained text encoder to identify promising regions of interest among notoriously noisy whole slide images. Without initial semantic conditioning, the model struggles to localize these regions.

We examine this empirically below: a model trained entirely from scratch on 25k samples (Rand-train) only modestly improves over a frozen random-initialized baseline (Rand). If we isolate the report-conditioning bottleneck by using a pretrained CONCH encoder solely for aggregation scoring (Rand-train (Conch agg.)), performance jumps substantially, confirming the need for baseline semantic alignment. However, it still lags behind the fine-tuned model (CONCH-Z@25k).

SPIDER task Rand Rand-train Rand-train(Conch agg.) CONCH-Z@25k
Skin-F 3.9 7.2 21.5 42.5
Colorectal-F 9.8 16.9 25.0 41.6
Breast-F 7.0 10.2 29.6 29.2
Thorax-F 5.8 15.8 17.2 44.0
Avg 6.6 12.5 23.3 39.3
Skin-C 14.3 21.3 24.6 52.4
Colorectal-C 19.0 24.3 41.6 48.0
Breast-C 11.4 17.7 44.0 60.9
Thorax-C 20.3 27.0 38.5 39.3
Avg 16.3 22.6 37.2 50.2

We conclude LIMIT is primarily suited for fine-tuning because the aggregation step relies on preexisting semantic alignment. However, we note that it generalizes to the strength of that initial alignment (e.g., PLIP, MUSK, Quilt). We will add this ablation and discussion to the revised paper.

Authors · CommentOpenReview ↗

2/2

A3. Supervised vs. Zero-Shot Baselines

Q3,W3: Why do supervised Table 3 baselines, especially CONCH-Zlin, underperform zero-shot CONCH-Z despite using labels?

We thank the reviewer for this observation. The performance differences are primarily driven by the difficulty of slide-level aggregation and the tendency for supervised models to overfit on downstream datasets.

Supervised methods (e.g., ABMIL, TransMIL) notoriously struggle to aggregate information across the ~10,000 patches per slide without patch-level annotations. They often rely on spurious correlations, such as prioritizing red blood cells because hemorrhage broadly correlates with cancer. This results in severe overfitting, which is evidenced by an average 12.1% gap between training and test performance on our supervised TCGA-ot46 models. Conversely, zero-shot methods leverage large-scale vision-language pretraining. This provides strong, generalizable priors that enable robust aggregation without further tuning.

As for why linear probes underperform, we hypothesize the performance gap is driven by two factors:

  1. CONCH-Zlin uses fixed aggregation. CONCH-Z dynamically adjusts its spatial attention during inference to independently localize relevant morphologies for each subtype. Training a standard linear probe, however, requires a single, unified slide-level representation as input. To meet this requirement, CONCH-Zlin must aggregate patch features using a single, static text query (such as "cancer"). Our ablation demonstrates that this structural bottleneck alone causes a 5.3% drop in balanced accuracy compared to dynamic, query-aware aggregation.
  2. The zero-shot embedding space is already well-structured from large-scale pretraining on clinical reports. In contrast, the linear probe must learn class separation from scratch in a 768-dimensional space using a relatively small and imbalanced dataset (8,226 TCGA-OT46 samples). Consequently, CONCH-Zlin overfits and suffers a 11.0% drop in balanced accuracy between training and testing. This vulnerability is consistent with prior findings on linear probing (Kumar et al., CVPR 2022).

We will clarify the architectural constraints of fixed-query aggregation and this intuition regarding overfitting in the revised manuscript.


A4. "Robustness" to synonym replacement

Q4,W4: Why does CONCH-Z show higher synonym-induced variance on Skin and Thorax, and should the robustness claim be softened?

We thank the reviewer for this clarification. We agree that the term "robustness" was too strong if interpreted as strict invariance to synonym perturbations. Our intended claim was that CONCH-Z maintains higher average performance across different synonym choices, not that its predictions are entirely insensitive to wording changes. We will revise our claims to avoid implying invariance and will note synonym sensitivity on this skin/thorax subset.


We thank the reviewer for their thoughtful comments and suggestions, which led us to better characterize the generalizability of LIMIT. Please let us know if you have additional questions or if we have addressed your comments.

Reviewer mcJX · CommentOpenReview ↗

I have read the answers from the authors to my raised concerns and thank them for the additional results and discussions. In particular, the experiments on 3 other foundation models (PLIP, Quilt, MUSK) are very appreciated.

Could the authors please detail how the "Rand-train(Conch agg.)" baseline in A2 is exactly implemented? They mention that they are "using a pretrained CONCH encoder solely for aggregation scoring" but it is not clear to me what this refers to. When mentioning "CONCH encoder", is it the vision or text encoder? Which parameters are trained in this setting?

Reviewer baLsOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper introduces Locked Image Multiple Instance PreTraining (LIMIT), a method for aligning slide-level pathology reports with patch-level visual features. LIMIT freezes the vision encoder and fine-tunes only the text encoder. For each candidate report, the report embedding is used as a query to attend over patch embeddings, producing a slide-level representation. Training with positive and negative reports, the pertaining produces three intermediate quantities for each candidate report: the report embedding, the patch attention scores conditioned on that report, and a report-conditioned slide representation. Using these quantities, the model is able to perform both supervised and zero-shot learning tasks on patch-level classification, tumor detection, and slide-level classification tasks. The results show strong zero-shot performance and competitive results compared with supervised MIL baselines.

Strengths and weaknesses

Strengths

  1. The paper is clear and well written.

  2. The motivation is strong. The paper addresses a real mismatch in pathology: reports are written at the slide level, but visual features are extracted at the patch level. Using the report embedding to guide attention over patch features is a natural way to connect these two levels.

  3. The results are strong across several tasks, including patch-level zero-shot classification, tumor detection, and slide-level classification. The comparison with both pathology VL models and supervised MIL baselines makes the evaluation convincing.

  4. The figures are very well designed. In particular, Figure 3 is clear and visually effective. The color scheme makes the paper enjoyable to read.

Weaknesses

One concern is the lack of ablations on the vision encoders. LIMIT freezes the vision encoder by design, which is reasonable, but it would be useful to see what happens if the vision encoder, a visual projection layer, or a lightweight visual adapter is also fine-tuned. This would help show whether the locked-image design is the best choice, rather than mainly a computationally convenient one. The authors also acknowledge that not adapting the image side may limit modeling of global slide-level properties.

The paper may overstate the use of full clinical reports. In the appendix, reports are processed by Qwen3-14B to extract only the core diagnosis phrase and remove organ/site details, laterality, staining, IHC markers, and explanatory clauses. This makes the supervision closer to cleaned diagnosis phrases than full pathology reports.

The report-conditioned pooling also raises an inference-cost question. Since each candidate text requires a separate query-guided aggregation over patches, inference cost scales with the number of candidate labels. This may be fine for small organ-specific candidate sets, but it should be discussed for larger label spaces.

Justification of my ratings

Quality: 3 Good. The method is reasonable, the experiments are broad, and the results are strong. More ablations on the vision side and report preprocessing would strengthen the paper.

Clarity: 3 Good. The paper is generally well written and the figures are clear.

Significance: 3 Good. The paper addresses an important problem in pathology: how to use scalable slide-level reports for vision-language alignment without requiring patch-level captions.

Originality: 3 Good. The combination of locked-image tuning, report-guided MIL attention, and zero-shot pathology classification is interesting and reasonably original.

Questions
  1. In the difficulty-weighted loss, are the report-similarity weights computed using the current trainable text encoder, a frozen copy of the text encoder, or detached embeddings? If they use the current encoder, how stable are these weights during training?
  2. Since the reports are normalized into core diagnosis phrases, is LIMIT mainly learning from slide-level diagnosis labels rather than full pathology reports? Would a simpler slide-level label-based pretraining setup achieve similar performance?
  3. How much does the organ-specific candidate restriction help in slide-level classification? Can the authors also report unrestricted classification performance, where the model selects from all diagnostic classes rather than only classes within the known organ?
Limitations

Yes

Final justification

The author has addressed all my cocerns during rebuttal. This paper solves a relevant issue in digital pathology, and additional analysis also shows the generalizability of this method. One limitation of the work is the report were pre-processed, not raw, free text reports. However, I don't think this limitation prohibits the practical value of the paper. Thus, I recommend 5: Accept of this paper.

Formatting concerns

None

4 comments
Authors · CommentOpenReview ↗

1/2

We are pleased to hear the reviewer found our work well written, well motivated, with strong results and figures.

A1. Ablations on Vision Encoders & Locked-Image Tuning [Metareview W3]

W1: What happens if the vision side is also adapted, and is freezing the image encoder a methodological choice rather than only a computational convenience?

We thank the reviewer for highlighting the importance of evaluating trainable vision components to better contextualize our approach. To address this, we conducted ablations on a randomly selected 25,000-sample training subset, evaluating: (1) an unfrozen visual projection layer, and (2) full-weight retraining of the visual encoder.

End-to-end training of the visual encoder—whether through full-weight updates or LoRA—exceeds standard memory limits for Whole Slide Images (WSIs). Backpropagating through the vision encoder for all ~10,000 patches (512x512 px) in a single WSI requires storing ViT activations that far exceed the capacity of high-end GPUs. In our benchmarking, dynamically re-encoding just 64 patches requires nearly 60 GB of GPU memory. Therefore, locked-image tuning is a computational necessity for WSI-level training, rather than solely a design convenience.

To make training the vision encoder feasible for this ablation, we adapted our pipeline (LIMIT-V) to operate on a restricted subset of patches: 1) We use frozen, precomputed features to rank all WSI patches and select the top-k patches most relevant to each diagnostic query. 2) Only these k patches are read from the WSI and dynamically re-encoded through the trainable vision encoder to compute gradients.

Shown below are the computational demands for training the unfrozen visual encoder (LIMIT-V) compared to our locked approach (LIMIT) for a single sample (averaged across 100 samples). Using this modified pipeline, training the LIMIT-V model with k=64 on 25k samples for one epoch took 44 hours to complete on an A100 GPU. Shown is peak VRAM usage, latency per forward and backward pass at different number of top-k patches per WSI for LIMIT / LIMIT-V

kk Peak GPU Mem (GB) Forward Pass (s) Backward Pass (s)
LIMIT LIMIT-V LIMIT LIMIT-V LIMIT LIMIT-V
8 4.3 14.4 0.126 0.577 0.057 0.291
16 4.3 20.2 0.127 0.802 0.059 0.530
32 4.3 31.9 0.133 1.168 0.060 0.753
64 4.3 55.3 0.133 4.687 0.063 1.435
128 4.3 OOM 0.138 OOM 0.064 OOM
All 4.8 OOM 0.184 OOM 0.082 OOM

Performance on SPIDER-C/F (408,235 total samples) is shown below: while both LIMIT and LIMIT-V improve over CONCH-1.5, LIMIT-V exhibits comparable performance to text-only finetuning while being substantially slower. We attribute this to the reduced supervisory signal induced by requiring a top-k operation.

CONCH-1.5 w/ LIMIT w/ LIMIT-V
Skin-F 38.0 42.5 39.1
Col-F 37.9 41.6 37.7
Breast-F 33.9 34.2 41.0
Thorax-F 35.4 39.0 38.8
Avg 36.5 39.3 39.5
Skin-C 43.8 52.4 44.2
Col-C 37.4 48.0 50.5
Breast-C 40.2 60.9 62.5
Thorax-C 29.7 39.3 39.1
Avg 39.0 50.2 49.1

A2. Report Preprocessing vs. Full Pathology Reports

W2,Q2:: Are the “reports” actually cleaned diagnosis/morphology phrases, and would a simpler slide-level label-pretraining baseline perform similarly?

The reviewer is correct that we remove confounding noise such as administrative details, laterality, and unrelated IHC markers to reduce noise and isolate pathologically-meaningful details during training. However, we do not believe that a simpler slide-level label-pretraining baseline would exhibit the same zeroshot transfer capabilities. Standard slide-level labels typically rely on a small, fixed vocabulary of discrete classes that flatten complex pathologies. In contrast, LIMIT leverages an open-vocabulary corpus that preserves the highly compositional nature of pathology (e.g., capturing fine-grained combinations like "poorly-differentiated" alongside specific architectural features like "giant cell features").

Retaining this morphological nuance yields a massive, long-tail distribution of 148,279 unique phrases across 335,645 records, providing a much richer signal than a closed label vocabulary. Furthermore, as shown in hKSf A2-3, the observed gains are independent of concept frequency. Moreover, 90-99% of the reports contain no mention of the target zero-shot labels, confirming that the model actively learns from the diverse vocabulary rather than simply overfitting to dominant classes.

Authors · CommentOpenReview ↗

2/2

A3. Technical Implementation of Difficulty-Weighted Loss

Q1: Are difficulty weights computed from the current text encoder, a frozen copy, or detached embeddings, and how stable are they during training?

The similarity weights are computed from detached embeddings produced by the active trainable text encoder. Importantly, gradients do not flow through this weighting component (Line 138). The weights reflect the current semantic geometry of the text encoder without introducing an additional gradient path. These detached weights lead to stable improvements at training scales (Table 4) and to diverse model backbones (see mcJX-A1). We will provide additional quantification of training stability in the updated manuscript.


A4. Inference Cost & Scaling with Candidate Labels

W3: How expensive is report-conditioned pooling at inference when each candidate label requires separate text-guided aggregation?

We thank the reviewer for highlighting this important detail about inference cost. The reviewer is correct that inference cost scales with the number of candidate labels, primarily due to the N×KN\times K similarity matrix for N patches and K labels. However, this computation is a single matrix multiplication, yielding low practical overhead. We show the computational demands of scaling the labels from 10 to 300 for a WSI with 10,000 patches, averaged across PLIP, Quilt, CONCH-1.5, MUSK, and MI-Zero for the text-guided aggregation step. Each label adds a negligible 0.002 ms in latency on average.

CPU and memory

Metric 10 25 50 75 100 200 300
CPU time (ms) 6.57 7.69 7.84 7.87 8.07 8.21 8.43
CPU RSS (MB) 3837 3580 3580 3580 3581 3581 3581
GPU peak (MB) 1306 1306 1306 1306 1306 1306 1306
GPU allocated (MB) 1280 1281 1282 1283 1284 1288 1292
GPU reserved (MB) 1590 1621 1661 1661 1662 1662 1662

Latency per model

Model 10 25 50 75 100 200 300 avg ms/label
PLIP 11.1 11.2 11.2 11.2 11.2 11.5 11.4 0.001
Quilt 3.1 3.2 3.2 3.2 4.0 3.6 3.9 0.003
CONCH 13.2 13.3 13.4 13.5 13.5 13.9 14.1 0.003
MUSK 6.0 6.0 6.0 6.1 6.1 6.6 6.9 0.003
MI-Zero 3.2 3.0 3.2 3.3 3.4 3.6 3.8 0.002
Mean 6.2 7.3 7.4 7.5 7.7 7.8 8.0 0.002

Thus, while LIMIT’s inference formally scales with the number of candidate labels, the practical cost is small because label-conditioned pooling reduces to an efficient patch-label matrix multiplication. This makes the method suitable not only for organ-restricted candidate sets but also for substantially larger diagnostic label spaces.


A5. Organ-Specific Restriction vs. Unrestricted Classification

Q3: How much does organ-specific candidate restriction help, and what is the unrestricted all-class slide-level performance?

Without organ restriction, zero-shot models experience a significant drop in accuracy: PLIP (8.9%), Quilt (11.8%), and CONCH-1.5 (34.1%). While CONCH-Z also declines, it remains the most robust zero-shot method at 60.8%. By contrast, supervised slide-level MIL baselines sustain higher accuracies across the board (ABMIL: 76.2%, TransMIL: 75.4%, CLAM: 77.4%).

This performance gap stems from differences in spatial context between slide- and patch-based models. Slide-level models can leverage macroscopic features (e.g surrounding benign stroma) to identify a slide's source organ. Patch-level models lack this broader context and rely strictly on high-magnification cellular morphology. This is a critical distinction because high-grade tumors (e.g., breast and lung adenocarcinomas) often lose organ-specific differentiation, making them structurally indistinguishable at the patch level without immunohistochemistry.

We emphasize that in standard clinical workflows, the organ of origin is a known prior routinely provided on surgical requisition forms. Evaluating models with organ restriction better aligns with this reality, ensuring the benchmark measures the model's ability to diagnose the specific disease rather than its ability to infer the source organ from macroscopic cues. However, these results shed light on an important limitation of patch-based models for slide-level evaluation, which we will be certain to include in our updated discussion of limitations. We discuss additional limitations with hKSf-A5.


We thank the reviewer for their insightful questions. Please let us know if there are any additional questions or if all concerns have been addressed.

Reviewer baLs · CommentOpenReview ↗

Response to rebuttal

Thank you for your rebuttal. I will keep my positive score after rebuttal.

Authors · CommentOpenReview ↗

We thank the reviewer for their thoughtful questions and will incorporate these changes into the final manuscript. Given your interest in the generalizability of our approach, we would also like to highlight our response to Reviewer hKSf-A7.2. By applying LIMIT pretraining to the public TCGA dataset, we show that our method successfully generalizes to accessible data with varying demographics, disease distributions, and digitization protocols.