CLR-voyance : Reinforcing Open-Ended Reasoning for Inpatient Clinical Decision Support with Outcome-Aware Rubrics
Aishik Nagar, Arun-Kumar Kaliya-Perumal, Yu-Hsuan Han, Andrew Sheng-Han Huang, Kristen Kee, Yushi Cao, Yiming Chen, Hongchao Jiang
NeurIPS 2026
Abstract. Inpatient clinical reasoning is a sequential decision under partial observability: the clinician sees the admission so far and must choose the next action whose downstream consequences are not yet visible. Existing clinical-LLM evaluations and reinforcement-learning (RL) rewards collapse this structure into closed-form retrieval, full clinical journey leakage, or unanchored LLM-as-judge scoring. Here, we introduce CLR-voyance, an end-to-end framework that reformulates inpatient reasoning as a Partially Observable Markov Decision Process (POMDP) and supervises it with rewards that are simultaneously outcome-grounded and clinician-validated. We instantiate the formulation as CLR-POMDP, which partitions successful patient journeys into a policy-visible past and an oracle-only future. Using the past information, an oracle LLM generates a case-specific query-answer pair, and the first adaptive rubric for clinical reasoning which is verifiable in the future of the patient journey. These rubrics are used for both RL post-training and evaluation of models for inpatient clinical reasoning. CLR-voyance post-trains Qwen3-8B and MedGemma-4B with GRPO followed by model merging, yielding state-of-the-art inpatient clinical reasoning while retaining generalist capabilities. CLR-voyance-8B achieves 84.91% on CLR-POMDP, ahead of frontier medical reasoning models like GPT-5 (77.83%) and MedGemma-27B (66.66%) and has comparable or better performance on existing medical benchmarks. To ensure that our setting is clinically meaningful, we conduct a large-scale clinician alignment study, where physicians curate per-case rubrics, grade candidate responses against them, and provide blinded pairwise preferences of model reasoning. This study provides insights on clinical LLM-as-a-judge and clinical preference-model selection, which can inform the community at large. CLR-voyance has been deployed for 6+ months at a partner public hospital, drafting thousands of reasoning-heavy inpatient notes and 1.03T+ tokens processed to date.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:47 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper introduces CLR-voyance, an end-to-end framework that reformulates inpatient clinical reasoning as a POMDP and supervises the model using rewards that are both outcome-grounded and clinician-validated. The problem is timely and the future-aware rubric construction is interesting, but I am not fully convinced that observed future actions can be treated as reliable clinical ground truth, since they may reflect local practice, patient preference, or suboptimal decisions rather than optimal care. The current experiments also do not clearly isolate the value of future-conditioned rubrics from simpler static or past-only rubrics, and some gains may be confounded by response length, model merging, or preferences of the grounded judge. I would particularly like to see length-controlled comparisons, direct static-rubric and past-only baselines, reward-component and merge ablations, and cross-oracle evaluation. Overall, I view the paper as borderline, and a strong rebuttal addressing these validity and comparison issues could meaningfully improve my assessment.
Final justification
After reviewing the rebuttal, most of the key concerns have been adequately addressed. Therefore, I recommend to accept this paper and suggest the authors to incorporate all necessary changes to improve the manuscript.
Read meta-review
Meta-review
The paper introduces CLR-voyance, an end-to-end framework that reformulates inpatient clinical reasoning as a POMDP and supervises the model using rewards that are both outcome-grounded and clinician-validated. The problem is timely and the future-aware rubric construction is interesting, but I am not fully convinced that observed future actions can be treated as reliable clinical ground truth, since they may reflect local practice, patient preference, or suboptimal decisions rather than optimal care. The current experiments also do not clearly isolate the value of future-conditioned rubrics from simpler static or past-only rubrics, and some gains may be confounded by response length, model merging, or preferences of the grounded judge. I would particularly like to see length-controlled comparisons, direct static-rubric and past-only baselines, reward-component and merge ablations, and cross-oracle evaluation. Overall, I view the paper as borderline, and a strong rebuttal addressing these validity and comparison issues could meaningfully improve my assessment.
Final justification
After reviewing the rebuttal, most of the key concerns have been adequately addressed. Therefore, I recommend to accept this paper and suggest the authors to incorporate all necessary changes to improve the manuscript.
2 comments
| Meta-review request | Result | Where |
|---|---|---|
| Cross-oracle evaluation | Re-grading the full test set (7,929 items) with MedGemma-27B, a different model family, preserves the ranking, with our model ahead of both references (ours 0.694, GPT-5 0.672, base 0.598, with the margin over GPT-5 at +2.2 points, 95% CI [+1.6, +2.7] excluding zero, and over base +9.6 points). HealthBench under OpenAI's GPT-4.1 grader preserves the improvement ordering, and judge-clinician agreement is indistinguishable across judge families (kappa 0.414 to 0.421) | Reply to VUsr, W2e, and 8qZF, Q1 |
| Ground-truth validity of the future | Observed care is not treated as optimal. The cohort is filtered to successful journeys with no re-admission or death within two years, and the reward grades past-verifiable reasoning-quality criteria rather than matching the logged action, so a sound alternative scores well and an unsafe plan is penalised regardless of the log. Four physicians reviewing 230 cases and 1,000 dyads flagged about 0.1% of queries invalid, accepted 89.1% of criteria unchanged, and graded at inter-rater reliability kappa 0.702 | Reply to Kcz5, Weakness 1, and 8qZF, Q3 |
Regarding the validity of observed future actions as ground truth. We do not treat observed care as optimal, and the clinician study is the external check, with the numbers in the table and the full argument in the reply to Kcz5. We will rename the construction "grounded in successful care trajectories" where the current phrase could read as an optimality claim, and consolidate this into the limitations (Appendix C.9).
Regarding attribution of the lead result. We will lead with the formulation's own contribution, outcome-grounded GRPO reaching parity with GPT-5 (77.99 vs 77.83), and present the weight-space merge as a required stage of the post-training recipe for the problem setting we introduce, not a detachable enhancement. The merge is inert on its own, since there is no clinical-reasoning artifact to merge with until GRPO produces one, and merging the base with itself returns the base. The gain comes only from recombining the GRPO reasoning circuits with the base, which the donor-isolation control shows directly, since only the GRPO task vector improves (+0.081 over base) while a norm-matched random vector (-0.450) and the SFT vector (-0.574) both fall below base. The end-to-end process is a practical necessity, because GRPO delivers the outcome-grounded accuracy but narrows the model and, in the wild, its output stability, and the merge restores it. In six months of hospital deployment, covering millions of clinical-reasoning note elements used daily by clinicians, the GRPO-only checkpoint terminates cleanly on 98.89% of completions, with the remaining 1.1% rejected by clinicians in every case, while the merged model does on 100%, so the merge is what makes a GRPO checkpoint a deployable clinical reasoner. We will label GRPO-only and merged results separately so each stage is legible, with the full isolation and deployment analysis in the reply to VUsr.
Length and the response-style question. Beyond the controls above, response lengthening is a documented property of RL reasoning training, and the blinded spine-cohort physicians explicitly endorsed comprehensive coverage as the desired clinical-decision-support behaviour in their written rationales, while the obesity cohort preferred answer-first brevity. The per-case rubric machinery preserves both signals separately, which we will present as a deployment-relevant finding, clinician-controllable response style, rather than as a confound to be averaged away.
Clarity. We will make the reporting fixes detailed in the reply to VUsr. They include the Landis-Koch correction (kappa 0.42 is moderate), a consolidated taxonomy table, a single naming scheme for the clinician study with each kappa's referent stated once, standardized Figure 2 labels, the oracle model and its three roles named in the main methods, the RL training-set size (5,099 admissions with 4 queries each), scoped novelty claims, and a new dedicated ablations section so the reward-component, merge-isolation, and rubric-baseline results are read on their own.
We believe the new controls, the direct reward-component ablation, the cross-oracle re-grade, and the clinician and deployment evidence address the validity and comparison concerns, and are glad to run further analyses within the discussion window.
- Rating
- 3/6
- Confidence
- 4/5
- Quality
- 2/4
- Clarity
- 2/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes CLR-voyance, a post-training framework for inpatient clinical reasoning over EHR trajectories. The authors formulate inpatient clinical reaosning problem as a POMDP, where the model partially observes only the patient history, not observing the latent patient state and decides the actions such as diagnosis, treatment, procedural or uncertainty. A future-aware grounded judge is proposed by accessing to the withheld future trajectory, constructing queries, references, and rubrics. These future-grounded rubrics are used as rewards for GRPO post-training, followed by model merging. The resulting model is evaluated on the held-out CLR-POMDP benchmark, external medical benchmarks, and clinician validation studies.
Strengths and weaknesses
Strengths
-
The POMDP formulation is well motivated for inpatient clinical reasoning, where it can only partially observe.
-
The future-aware construction is an interesting way to ground open-ended clinical reasoning evaluation in downstream patient trajectories.
Weaknesses
-
Although the POMDP formulation is well motivated, the actual training is not related to a POMDP. The model does not perform model the latent patient state. The optimization is closer to single-turn response-level RL, which weakens the connection between the formulation and the proposed training method.
-
The main methodological claim relies on future-aware rubric rewards, but the paper does not include a direct comparison with RaR-style baselines. For example, static rubrics or past-only rubricswithout future access would help strengthen the contribution of the proposed future-aware grounded judge.
-
Relevant work on rubric-based agent post-training [1,2] is not sufficiently discussed or compared, especially given that this paper also frames clinical reasoning as a sequential decision-making problem with outcome-aware rewards.
-
The main results are hard to interpret because the model variants and merging notation are not clearly organized. While SFT and GRPO ablations are included, their relationship to the final CLR-voyance models is difficult to follow, and direct comparisons to relevant RaR-style or static-rubric reward baselines are missing.
[1] Loye, Xian Qi, et al. "RUBAS: Rubric-Based Reinforcement Learning for Agent Safety." arXiv preprint arXiv:2606.04051 (2026).
[2] Raghavendra, Mohit, et al. "Agentic Rubrics as Contextual Verifiers for SWE Agents." arXiv preprint arXiv:2601.04171 (2026).
Questions
-
How sensitive are the results to the choice of the teacher model used to generate queries, references, and rubrics?
-
Does the model learn clinically robust reasoning, or mainly learn to satisfy the style and preferences of the Grounded Judge?
-
Can future trajectories be treated as reliable ground truth, especially when actual clinical decisions may be noisy, biased, or suboptimal?
Limitations
The limitation is discussed in C.9.
Final justification
The rebuttal resolves several of my original concerns. In particular, the added past-only/static-rubric comparisons provide useful evidence for the value of future conditioning, and the authors have clarified the POMDP framing, model variants, and judge sensitivity.
My main remaining concern is originality. I agree that using the withheld downstream patient trajectory to construct a patient-specific rubric is a distinctive design choice. However, I still see this primarily as an extension/composition of existing contextual or instance-specific rubric-based evaluation and rubric-as-reward methods, where additional future information is provided to the rubric generator. The new ablations demonstrate that this information is useful, but they do not substantially change my assessment of the methodological novelty of the approach. Thus, while the rebuttal has strengthened the paper and addressed several technical concerns, my concern about the level of novelty remains, and I will maintain my original score.
Formatting concerns
N/A
2 comments
Rebuttal
Rebuttal to Reviewer 8qZF
We thank the reviewer for a careful review that isolates two points, how the POMDP formulation relates to the optimizer and the need for direct static and past-only rubric baselines.
Part 1. POMDP framing and rubric baselines
1. POMDP formulation vs single-turn training (Weakness 1)
- The optimization step is single-turn response-level RL, and the paper does not claim a learned belief-state policy or a multi-turn planner. Section 3.1 formalizes each admission as a POMDP where the policy observes the event stream up to a decision point and selects a single next action, with the reward computed from the withheld remainder, so the partial observability is a property of the task and the reward, not of the optimizer.
- The split point is sampled per query from a Gaussian over the event sequence, so queries land at different stages of the admission without a hand-coded taxonomy, and this is what gives an open-ended inpatient question a verifiable answer, since its answer is defined only relative to information the policy cannot see. We will state this in Section 3 and name multi-turn optimization as the next step.
2. Static and past-only rubric baselines (Weaknesses 2 and 4)
We re-graded the identical stored responses of our model, GPT-5, and the Qwen3-8B base under three rubric constructions on a fixed 250-admission slice (974 items), holding the benchmark, responses, and grading judge fixed so only the rubric construction varies (length matched at the median).
- We score each rubric construction's quality the way reward models and LLM judges are validated (RewardBench, JudgeBench), by how well its ordering agrees with a fixed ground-truth ordering rather than by its raw scores. The three rubric settings cannot be ranked by the standalone per-construction scores, since each rubric has its own leniency, so raw scores are not comparable. We align with prior work to compare rubric quality based on agreement with a fixed clinical expert preference, which is invariant to rubric leniency. On the paper's Phase-2 clinician study, where four physicians gave blinded A/B preferences over response pairs with no rubric shown, we graded both responses in each of 422 decided dyads under each construction and checked whether it ranked the physician-preferred response higher, so a construction that agrees more is the higher-quality reward and metric.
| Rubric construction | mean agreement with the physician preference across all model pairs | agreement on GPT-5 vs ours |
|---|---|---|
| Future-conditioned (paper's) | 69.4% | 62.8% |
| Past-only | 66.9% | 57.3% |
| Static generic | 63.8% | 58.5% |
- The future-conditioned rubric agrees with physicians most and is the best-agreeing construction in every comparison pair, including GPT-5-vs-ours, so it is the highest-quality signal. Both per-case rubrics beat the patient-independent one, so patient-specific grounding drives the agreement and future conditioning is its strongest form, on human ground truth rather than our model's scores.
| Rubric construction | ours | GPT-5 | base | ours - GPT-5 (95% CI) |
|---|---|---|---|---|
| Future-conditioned (paper's) | 0.724 | 0.680 | 0.660 | +0.044 [+0.025, +0.063] |
| Past-only (future withheld) | 0.883 | 0.730 | 0.755 | +0.153 [+0.129, +0.177] |
| Static generic (fixed criteria) | 0.744 | 0.803 | 0.809 | -0.059 [-0.088, -0.031] |
- The past-only rubric inflates our margin rather than deflating it (+0.153 versus the future-conditioned +0.044), because generic coverage criteria stop separating a right answer from a plausible-sounding wrong one. Blind to which action was clinically decisive, the past-only generator writes vague criteria a non-concrete response satisfies as readily as a correct one, writes patient-specific safety criteria about half as often (0.45% versus 0.8%), and invents 489 one-off themes across 977 rubrics instead of reusing the seven canonical ones.
- A patient-independent generic rubric cannot check whether a response gives the correct answer for the specific patient, so it scores broad coverage rather than the correct decision and is not a valid reward or metric. We show this against the reference answer itself, not against our model.
- On an anemia case whose reference answer is an upper and lower GI endoscopy for occult GI blood loss, the generic rubric gives full marks to a base response that names no procedure and near zero to our response that names the endoscopy, ranking a response that misses the correct answer above one that gives it.
- The negative imprecise-information criterion penalises detail whether or not it is correct (firing on 23.8% of the more detailed responses), introducing noise in the static, generic rubric. This is why it even ranks the untrained base above both trained models (base 0.809, GPT-5 0.803, ours 0.744) and scores the same responses 0.746 under it versus 0.838 under the per-case rubric.
- Future grounding is the right choice even under imperfect trajectories, because a past-only rubric can reward the wrong answer, not just a generic one. On a patient with anemia and coagulopathy after an attempted endoscopic cyst-gastrostomy, the correct diagnosis is chronic pancreatitis, which the future-conditioned rubric rewards while the past-only rubric rewards a "hematologic disorder" and marks the correct answer wrong. On 18% of cases the future-conditioned rubric names a specific clinical entity the past-only rubric omits entirely, and physicians accepted 89.1% of the grounded criteria unchanged (Appendix C.5).
Part 2. Related work and result organization
3. Cited related work (Weakness 3)
- Under the NeurIPS policy that work online within two months of the deadline is contemporaneous, RUBAS (arXiv 2606.04051, June 2026) appeared after the deadline, and we will be happy to cite it as contemporary work. We thank the reviewer for the agentic-rubric SWE work (arXiv 2601.04171), which we will discuss in Related Work, and mention that it shares per-instance contextual verification but grounds in repository state rather than a patient's downstream trajectory and carries no clinical-validity requirement.
- Scoped to that intersection, our contribution is the first per-case rubric conditioned on the withheld future of a real patient trajectory, past-verifiable at grading time, and used as both the RL reward and the evaluation metric for inpatient EHR reasoning. Grounding the rubric in the patient's realized causal outcome, rather than a static reference such as a code repository, is novel to this setting.
4. Result organization (Weakness 4)
We will reorganize the results so the variants and ablations are unambiguous, adding a consolidated taxonomy table, a single naming scheme separating GRPO-only from merged columns everywhere including a relabeled Figure 2, and a dedicated ablations section for the reward-component, merge-isolation, and rubric-baseline results.
Part 3. Questions
Q1. Sensitivity to the teacher model
We measured sensitivity at every point where the oracle or judge is involved in the evaluation or the reward (Section 5, Appendix C), and add a new cross-family oracle/judge re-grade to the analysis.
| Grading judge | judge-clinician agreement (kappa) |
|---|---|
| Qwen3-32B (ours) | 0.419 |
| GPT-4.1 | 0.414 |
| GPT-5 | 0.420 |
| MedGemma-27B | 0.421 |
- The grading signal is statistically indistinguishable across judge families (kappa 0.414 to 0.421), so it is not an idiosyncrasy of the Qwen teacher (Section 5, Appendix C). The oracle-generated queries are clinician-validated, since across 1,230 annotation events the physicians marked no Phase-1 case invalid and only a single dyad irrelevant, about 0.1%.
- A new cross-family re-grade of the full test set (7,929 items) with the MedGemma-27B judge preserves the ranking, ours 0.694, GPT-5 0.672, base 0.598, the margin over GPT-5 at +2.2 points (95% CI [+1.6, +2.7]) and over base at +9.6. A full teacher-swap of the rubric generator would require retraining, which the window does not allow, but these measurements cover every point where the teacher affects a reported number.
Q2. Robust reasoning or satisfaction of the judge's style?
- The strongest evidence is judge-free, since four blinded physicians prefer our model over GPT-5 decisively in the spine cohort and at parity in obesity, and a stylistic artifact of the automated judge cannot produce a blinded human preference (Section 5, R1).
- The improvement transfers to externally graded benchmarks where our judge plays no role, HealthBench under OpenAI's GPT-4.1 grader and DDXPlus, MedMCQA, MedCalc, and Mimic-Instr under exact-match scoring. The model also triggers the rubric's negative-point safety criteria less often than GPT-5 (1.30% vs 1.79%), the opposite of what stylistic reward-hacking would produce, and large-scale hospital adoption of CLR-voyance 8B is further practical evidence beyond any judge.
Q3. Can future trajectories be treated as reliable ground truth?
- The cohort excludes admissions with re-admission or death within two years (Section 3.1), so each conditioning trajectory reached a verified successful discharge, and the reward grades past-verifiable reasoning-quality criteria rather than a specific logged action, so a sound alternative suggested by the policy also scores well, and an unsafe plan is penalised regardless of the log.
- Most importantly, clinician validation (Section 5, Appendix C.5) provides the expert check, and physicians accepted 89.1% of criteria unchanged and flagged no case as clinically invalid. Some noise may remain in the trajectories, and we will consolidate this into the limitations (Appendix C.9).
The rubric-baseline experiment, the teacher-sensitivity measurements, and the structural revisions address the core concerns, and we thank the reviewer for insights that strengthen the paper.
Dear Reviewer,
Thank you again for the time you put into reviewing our submission.
As the discussion period draws to a close, we would be grateful if you could let us know whether any concern remains open, and we will address it within the remaining window. If our responses have resolved your concerns, we would kindly ask you to consider whether your assessment might be updated to reflect that.
With thanks, The Authors
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes a framework for in-patient clinical decision support which converts longitudinal EHR admissions into a partially observable trajectories. In this framework, the model sees only the past patient events, while an oracle LLM sees the future trajectory to generate a) a question, b) a reference answer, c) supporting evidence, and d) a rubric for the instance. The rubric-based reward is then used both for GRPO-based post-training and for evaluation. The authors report that their model trained on these reward functions beats established closed source general LLMs as well as medical LLMs on their CLR-POMDP benchmark.
Strengths and weaknesses
Strengths:
- The paper's formulation of the problem is reasonable (decision support is partially observable, and you can only verify your actions after observing the future events).
Weaknesses:
- The paper does not discuss whether future actions are optimal or merely observed actions. Assuming the former is a strong assumption - they can also just reflect local practice or patient preferences. I would appreciate some discussion about the validity of this implied assumption. Relatedly - matching these actions is not necessarily "outcome-grounded", but rather closer to "behavior-cloning".
- In the spine tests, people picked the longer version most of the time when they had a clear preference and the scoring system also gives extra points for listing out more details. But in the obesity tests (which actually deduct points for being too wordy) CLR-voyance only ties with GPT-5 at 48%. This suggests that part of its apparent win may simply come from being longer (the CLR-voyance model writes much longer answers than GPT-5), not from being clinically better. It would be more convincing if you ran head-to-head tests where both answers were the same length on the main benchmark.
Questions
- How do we know that future conditioning truly matters for rubric design (as opposed to just having past-only rubrics)?
- How often does the grounded judge produce future-leaking criteria? Are there mechanisms to prevent that? I worry that since the judge knows about the future, it may expect the agent to know something it CANNOT know..
- The term CLR is never defined in the paper?
Limitations
Yes.
Final justification
The authors' response addressed my concerns. I am therefore increasing my score and confidence to 5 and 4 respectively.
Formatting concerns
No
2 comments
Rebuttal
Rebuttal to Reviewer Kcz5
We thank the reviewer for concerns that map onto testable analyses and for stating the ground-truth-validity question precisely. We address the two weaknesses and three questions below, in two parts.
Part 1 of 2. Ground truth and the length confound (Weaknesses 1 and 2)
1. Are observed future actions valid ground truth? (Weakness 1)
- Observed care is not guaranteed optimal, and the design does not treat it as such. CLR-POMDP excludes admissions with re-admission or death within two years (Section 3.1), so each conditioning trajectory reached a verified successful discharge and sustained recovery. This bounds the futures to care whose end state was acceptable, without asserting per-decision optimality.
- The supervision is not behaviour cloning, and the policy is never rewarded for reproducing the logged action. The future selects which questions are well-posed and which criteria discriminate for this patient, and the criteria themselves are pass/fail statements about reasoning quality (differential coverage, risk assessment, citing the patient's actual labs and medications, safety) that are verifiable from the past plus the response. A clinically sound alternative to the logged action therefore satisfies most criteria, and negative-point criteria penalise unsafe proposals regardless of the log.
- The strongest external check is the clinician study, where across 230 cases and 1,000 dyads the four physicians marked zero cases and one dyad invalid (0.1%), accepted 89.1% of criteria unchanged, and graded at inter-rater reliability kappa 0.702.
- We will rename "outcome-grounded" to "grounded in successful care trajectories" where the shorter phrase could read as an optimality claim, and state this scoping in the limitations.
2. The length confound (Weakness 2)
We tested directly whether our advantage is an artifact of longer responses, at matched length on the automated benchmark across 7,929 paired instances against GPT-5, and the paper reports length-controlled win rates from the clinician study (Appendix C.9).
| Length control | ours | GPT-5 | ours decisive win rate |
|---|---|---|---|
| Matched length (within +/-25% of GPT-5, n=454) | 0.775 | 0.752 | 72.4% |
| Relative-length bins (1-1.25x, 1.25-2x, >2x) | 72% to 78% in every bin |
- At matched length our model still wins, 0.775 versus GPT-5's 0.752 with a 72.4% decisive win rate, and the win rate holds between 72% and 78% in every relative-length bin. The advantage is present when length is held fixed and does not grow with verbosity, which is the opposite of what a length artifact would show.
- Our score is uncorrelated with our own response length (r = 0.00, versus +0.15 for GPT-5), so our longest answers are not our best-scoring ones.
- The added length carries clinically meaningful content, as the physician evidence shows. In the paper's clinician study (Section 5 and Appendix C.5), the spine cohort prefers our model 85.6% over GPT-5, with written qualitative selection rationales valuing comprehensiveness ("missing something is medical negligence"), our model satisfies 73.6% of positive rubric criteria against GPT-5's 68.2%, and it triggers negative-point safety flags less often (1.30% vs 1.79%, a 27% relative reduction). The obesity cohort, whose rubrics penalise verbosity, still ties GPT-5, which a pure length artifact could not produce.
Part 2 of 2. Questions
Q1. Does future conditioning matter, versus past-only rubrics?
We regenerated rubrics on a fixed 250-admission slice (974 items) with the identical prompt, exemplars, and schema but the future withheld, then re-graded the same stored responses, and also graded them against a fixed patient-independent generic rubric, so all three constructions are directly comparable (length matched at the median).
- We score each rubric construction's quality the way reward models and LLM judges are validated (RewardBench, JudgeBench), by how well its ordering agrees with a fixed ground-truth ordering rather than by its raw scores. The three constructions cannot be ranked by the standalone per-construction scores below, because each rubric has its own leniency, whereas agreement with a fixed human preference is invariant to it. On the paper's Phase-2 clinician study, where four physicians gave blinded A/B preferences over response pairs with no rubric shown, we graded both responses in each of 422 decided dyads under each construction and checked whether it ranked the physician-preferred response higher, so a construction that agrees more is the higher-quality reward and metric.
| Rubric construction | agreement with the physician winner | on GPT-5 vs ours |
|---|---|---|
| Future-conditioned (paper's) | 69.4% | 62.8% |
| Past-only | 66.9% | 57.3% |
| Static generic | 63.8% | 58.5% |
- The future-conditioned rubric agrees with physicians most and is the best-agreeing construction in every comparison pair, including GPT-5-vs-ours, so it is the highest-quality signal. Both per-case rubrics beat the patient-independent one, so patient-specific grounding drives the agreement and future conditioning is its strongest form, on human ground truth rather than our model's scores.
| Rubric construction | ours | GPT-5 | base | ours - GPT-5 (95% CI) |
|---|---|---|---|---|
| Future-conditioned (paper's) | 0.724 | 0.680 | 0.660 | +0.044 [+0.025, +0.063] |
| Past-only (future withheld) | 0.883 | 0.730 | 0.755 | +0.153 [+0.129, +0.177] |
| Static generic (fixed criteria) | 0.744 | 0.803 | 0.809 | -0.059 [-0.088, -0.031] |
- Our margin more than triples under the past-only rubric (+0.153 versus the future-conditioned +0.044), because generic coverage criteria that a non-concrete answer satisfies stop separating a right answer from a plausible wrong one. Two signals confirm the past-only rubric is less discriminating rather than just harder on us, since it writes patient-specific safety criteria half as often (0.45% versus 0.8% of criteria) and invents 489 one-off themes across 977 rubrics instead of reusing the seven canonical ones.
- A patient-independent generic rubric cannot check whether a response gives the correct answer for the specific patient, so it scores broad coverage rather than the correct decision and is not a valid reward or metric for this task. We show this against the reference answer itself, not against our model.
- On an anemia case whose reference answer is an upper and lower GI endoscopy for occult GI blood loss, the generic rubric gives full marks to a base response that names no procedure and near zero to our response that names the endoscopy, ranking a response that misses the correct answer above one that gives it.
- The problem is in the rubric's design, since its negative imprecise-information criterion penalises detail whether or not the detail is correct (firing on 23.8% of the more detailed responses) and its patient-independent criteria credit a response for citing some evidence without checking that the evidence is the right evidence. A rubric built this way scores coverage rather than the correct decision, which is why it even ranks the untrained base above both trained models (base 0.809, GPT-5 0.803, ours 0.744) and scores the same responses 0.746 under it against 0.838 under the per-case rubric.
- Future grounding is the right choice even under imperfect trajectories, because a past-only rubric can reward the wrong answer, not just a vaguer one. On a patient with anemia and coagulopathy after an attempted endoscopic cyst-gastrostomy, the future-conditioned rubric rewards the correct chronic-pancreatitis diagnosis while the past-only rubric rewards a "hematologic disorder" and marks the correct answer wrong. Across the slice it names a specific clinical entity the past-only rubric omits entirely on 18% of cases.
- Clinician curation confirms the grounded criteria are sound, with physicians accepting 89.1% of criteria unchanged and concentrating edits on the content axes the future informs. These examples will accompany the ablation in the revision.
Q2. How often does the judge produce future-leaking criteria, and what prevents it?
- The rubric-generation prompt forbids referencing the future in criterion text, so the future selects which criteria matter while the criteria themselves must be past-verifiable. A de-duplication pass catches repeats, and clinician curation feeds back as in-context exemplars.
- The clinical curation measured the residual. Criteria quoting a future event were among the reasons physicians marked criteria not suitable, and the overall not-suitable rate was 10.9% of oracle criteria, which is an upper bound on all failure modes including leakage. Appendix C.4 documents leakage as a small number of cases.
- The curated in-context exemplars steer the rubric criteria generator away from it, and we will report the leakage rate in Section 3.2 rather than only in the appendix.
Q3. The term CLR is never defined.
- CLR stands for Clinical Reasoning, so CLR-POMDP is the Clinical Reasoning POMDP, and the name is a play on clairvoyance, since the oracle sees the patient's future. We will define it at first use and explain it at the beginning of the paper in the revised manuscript.
We thank the reviewer again, and hope the matched-length analysis and the past-only and static-rubric ablations address the length and ground-truth concerns.
Dear Reviewer,
Thank you again for the time you put into reviewing our submission.
As the discussion period draws to a close, we would be grateful if you could let us know whether any concern remains open, and we will address it within the remaining window. If our responses have resolved your concerns, we would kindly ask you to consider whether your assessment might be updated to reflect that.
With thanks, The Authors
- Rating
- 5/6
- Confidence
- 5/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 4/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
CLR-voyance is a framework for inpatient clinical decision support. The premise is that inpatient care is a decision under partial observability, where a clinician sees only the past, and a decision was right is revealed only by the patient's future care trajectory. The thesis is that existing clinical-LLM benchmarks and RL rewards break this structure, either by leaking the answer into the model's context or by scoring with static, outcome-agnostic rubrics. Two core contributions address this. (1) CLR-POMDP: a task built from MIMIC-IV event streams (~65K tokens) that splits each admission into a policy-visible past and a withheld, oracle-only future across four clinical action spaces, so the answer to each question lies in the future rather than in the provided context, and the same construction is used for both training and evaluation. (2) The Grounded Judge: an oracle model (Qwen3-32B) that, with access to the withheld future, writes a per-case question, a reference answer, and a rubric tailored to that patient's actual downstream trajectory; a second call of the same model then grades a candidate answer against that rubric to produce a dense scalar reward. This one reward is used both to train the policy with GRPO and to score models at evaluation. The framing is supported by a post-training recipe (GRPO followed by off-the-shelf DELLA weight-space merging, on Qwen3-8B and MedGemma-4B), a four-physician two-cohort clinician validation study, and a reported six-month, 1.03T-token hospital deployment.
Key findings reported. CLR-voyance-8B reaches 84.91% aggregate on the CLR-POMDP benchmark, ahead of GPT-5 (77.83%), the Qwen3-8B base (75.28%), and MedGemma-27B (66.66%); GRPO alone brings the base to 77.99%, and the DELLA merge adds the remaining 7 points. Improvements over GPT-5 concentrate on the outcome-grounded content axes (Completeness +21.4, Accuracy +11.1), while the conversational axes sit at or slightly below GPT-5; general-purpose reasoning-distilled models transfer poorly (DeepSeek-R1-Distill at 11.99%). In the clinician study, the Grounded Judge's per-criterion grades agree with physician grades at κ=0.42 (moderate agreement on the Landis–Koch scale), and physicians flagged only 0.1% of the oracle-generated questions as clinically invalid, i.e., almost every auto-generated question was judged answerable and clinically meaningful.
Strengths and weaknesses
Strengths
-
The framework is a real conceptual advance, and this is where the paper's value lies (Significance / Originality). A future-grounded, per-case rubric benchmark that doubles as a training distribution is genuinely new relative to eval-only clinical benchmarks. The per-case, patient-trajectory-conditioned rubric as an RL reward is a novel mechanism, and Appendix A's 11-pillar contrast matrix positions it against a large body of prior work.
-
An 8B open model reaching parity with GPT-5 is a strong result on its own. Setting the model merge aside, GRPO on the outcome-grounded rubric alone lifts Qwen3-8B to 77.99%, essentially level with GPT-5 (77.83%) on CLR-POMDP test set. An 8B open-weight model trained on the reward formulation proposed in the paper matches a frontier system is compelling, and in my view should be the headline of the paper. However, as written currently, it reads diminished against the merged number (see Weaknesses).
-
Clinical deployment: A 6-month, 1.03T-token production deployment along with a four-physician two-cohort clinician study (IRR κ=0.702; judge-clinician κ=0.42), and failure-mode reporting (fabrication, DDI-hazard misses, cardiac over-inference; Appendix D) make this one of the more clinically substantive papers in the area. The clinical reward formulation is cleanly specified (Sec 3.2, Eq. at p.4 line 167).
-
Useful negative results: general-purpose reasoning-distilled checkpoints transfer poorly to inpatient EHR reasoning (DeepSeek-R1-Distill at 11.99%). Even though I question the causal framing of the latter (see Weaknesses), the empirical findings themselves are practically valuable to anyone post-training clinical reasoning models.
-
Dataset construction - leakage-aware design, that is, ICD-source removal so diagnosis is reasoned not read off a code.
-
Diagnosable reporting at the level of per-axis + per-action-space decomposition.
Weaknesses
(1) Over-claims that undercut the core value.
-
The headline gain is delivered by an off-the-shelf merge, not by the framework. On Qwen3-8B (Table 5, p.26): base 75.32, GRPO 77.99 (+2.67), GRPO+DELLA merge 84.95 (+6.96). The outcome-grounded GRPO, the core contribution, only ties GPT-5. However, the entire ~7-point "win" is the weight-space merge, which is prior work (DELLA/Breadcrumbs/AIM). The paper concedes GRPO alone is "marginally above GPT-5" (p.6, line 239). Presenting the merged number as the headline attributes the paper's success to a component that is not its idea.
-
The merge is unreliable, which shows it is luck rather than method. The same merge that adds +6.96 pp on Qwen3-8B does nothing for MedGemma-4B (goes from 63.40 to 63.35; Table 7). it only re-balances axes. A booster that helps one family and not another is does not give a repeatable recipe and building the headline on it is fragile.
-
Smaller claims are inflated too. The paper reports the judge-clinician agreement of κ=0.42 as "substantial (Landis-Koch)" (p.8), but on the Landis-Koch scale 0.41-0.60 is moderate, not substantial, a mislabel that overstates how well the automated Grounded Judge tracks physicians, which matters because the same judge is both the reward and the metric. This pattern of upgrading results by a notch recurs and should be corrected.
-
Overclaimed novelty: Rubric-as-reward for medicine already exists (Gunjal et al. "Rubrics as Rewards" on HealthBench; Clinical-R1/CRPO rule-based GRPO). The novelty is defensible only at the exact intersection (per-case + future-trajectory-conditioned + RL reward + inpatient), yet the abstract and the prior work generalizes the work as being the first.
-
The reasoning-distilled claim (DeepSeek at 11.99% to "verifiable-reward post-training does not transfer," p.7) is confounded. CLR-POMDP is both OOD for DeepSeek along with the training mechanism not following the proposed adaptive rubrics. Ablations can help clarify this claim.
(2) Missing experimental detail and controls (Quality).
-
The merge's gain is unexplained. Merging is motivated as recovering "generalist capabilities," but the merge step boosts the clinical-content axes, not the conversational ones: Qwen3-8B (Table 5) Accuracy +11.56, Completeness +13.06, Context +5.90 vs Comm/Instr +0.35/+1.46; MedGemma-4B (Table 7) Accuracy +7.48, Completeness +11.32 while Comm −16.22, Instr −5.60. Worse, on those axes the merged model beats both parents (Accuracy 80.77 vs base 66.57 and GRPO 69.21).
-
Table 1 reports only base and merged checkpoints, so external-benchmark gains are equally unattributable. On the four external benchmarks (Table 1, p.7), each family shows only the base and the merged Δ model, e.g., Qwen3-8B base vs Qwen3-Della Merged, missing GRPO-only or SFT-only column. As we see in Fig 2, merged model shows the most gain over GPT 5 and GRPO alone (although better than base) matches GPT 5 performance, I have the same doubt for table 1 results.
-
No reward-component ablation. r_total = r_rub + r_format + r_tag at unit weights is asserted but never decomposed. So even the +2.67 pp GRPO gain is not attributed to the outcome-grounded rubric vs the generic format/tag scaffolding.
-
No evidence the framework scales or generalizes. The strongest way to show the formulation (not the tricks) is responsible for the gains would be a same-family scaling study with GRPO only, no merge e.g., Qwen3-4B to 8B to 14B. The scaling result could help establish that the framework itself is the load-bearing contribution and that it generalizes, the current single-8B-plus-merge result cannot make that case.
-
The RL training-set size is never reported anywhere (only the 7,927-admission test set is given), and oracle-family circularity (Qwen3-32B grading a Qwen3-8B policy) is never tested with a non-Qwen oracle. Both are basic reproducibility/validity gaps.
(3) Lack of clarity in the paper
-
Overloaded taxonomies. The methods juggle overlapping schemes - 5 grading axes, 4 action-spaces, 7 rubric "themes" (Appendix B.5). "Grounded Judge" names three different calls (write question, write rubric, grade). "adaptive," "per-case," "per-sample," "outcome-aware," and "trajectory-conditioned" rubric seem to be used interchangeably which becomes difficult to follow.
-
The clinician-validation section (Sec 5) is hard to follow. It packs A/B preference, rubric curation, judge-alignment, and preference-model benchmarking into a few dense paragraphs under two reversed naming schemes (body R1/R2/R3 vs appendix Phase-1/Phase-2, where R1 = Phase 2); it reports three very different κ's for three different comparisons - 0.702 human–human rubric IRR, 0.42 judge–clinician, 0.034/0.051 human–human A/B preference - scattered across prose and tables and easy to conflate. Qwen3-32B appears as both the system oracle and a benchmarked competitor judge in the same tables (Tables 2–3), where its clinician agreement (κ≈0.42) is no better than GPT-4.1's or GPT-5's.
-
Figure 2 , the key result figure, uses inconsistent naming for identical methods."BC" vs "Breadcrumbs", three base-model prefixes, "GRPO" dropped from some merge labels and kept in others, "DELLA" vs the text's "DELLA-Linear". Font size should also be increased.
Questions
Questions & suggestion in context of the three core weakness shared above. Given the significance and impact of the work, would be inclined to increase score if paper clarity and experimental completeness are improved.
- Clarity & reporting
-
Lay out the four taxonomies (5 axes, 4 action-spaces, 7 themes, critical-accuracy) in one place, name the oracle model (Qwen3-32B) and its three roles in the main methods (main body of the paper not appendix), and define "adaptive rubric" once.
-
Restructure Sec 5 under a single naming scheme (not both R1–R3 and reversed Phase-1/2), mention which κ measures what, and separate the two "LLM-as-a-judge" analyses.
-
Standardize Figure 2's model naming.
-
Report the RL training-set size.
- Reduce over-claims
-
Lead with the honest headline, an 8B open model at parity with GPT-5 via outcome-grounded GRPO, and present the merged 84.91% as a clearly-labeled off-the-shelf add-on, stating that the merge is not your contribution and does not help the MedGemma family.
-
Scope the "first rubric-as-reward" claim to the actual intersection (per-case + future-conditioned + inpatient) and potentially drop the causal "verifiable-reward does not transfer" gloss (if not experimentally ablated), since the DeepSeek result is confounded by domain and OOD format.
-
Correct the smaller inflations, e.g. κ=0.42 is moderate, not "substantial," on the Landis-Koch scale.
- More experiments
-
Isolate the merge. Add a merge-over-SFT arm and a merge-over-base/self-merge control. If merging Δ_sft (or a randomized task vector) lifts similarly, the +6.96 pp is generic base-restoration and the win over GPT-5 is not attributable to your RL, if only the GRPO task vector lifts, the merge is amplifying your signal.
-
Reward-component ablation. I want to see how the different reward components, especially outcome-grounded rubric alone drives the GRPO gain.
-
Same-family scaling, GRPO-only, no merge (Qwen3-4B, 8B, 14B). Monotone improvement would show the framework is the load-bearing contribution and generalizes, independent of merging.
-
Cross-oracle evaluation. Re-grade CLR-POMDP with a non-Qwen oracle (e.g. GPT-4.1, MedGemma-27B), preserved rankings would defuse the same-family circularity, a reversal would undermine the benchmark.
Limitations
Refer to questions and weakness
Final justification
I thank the authors for their detailed clarifications and additional experiments. After reviewing the rebuttal, I believe my concerns have been adequately addressed.
For the final revision, I would encourage the authors to further improve the clarity and positioning of the work and to incorporate the relevant ablation studies conducted during the rebuttal. These additions would better demonstrate the experimental thoroughness of the paper.
Given the authors’ responses and new results, I am increasing my score.
Formatting concerns
none
5 comments
Rebuttal
Rebuttal to Reviewer VUsr
We thank the reviewer for identifying the paper's core contribution, and answer each weakness in the reviewer's order.
W1a. The formulation and the merge are one
- The weight-space merge is not a detachable add-on to be set aside. CLR-voyance is a single formulation whose novelty is the formulation as a whole, the problem setting, the outcome-grounded reward, and a post-training recipe which reinforces clinical reasoning while also repairing the regressions GRPO introduces.
- The merge is not a free-standing source of performance, since it cannot help the base on its own. Merging the base with itself will just return the base model. The gain comes only from merging the base with the GRPO reasoning circuits (donor-isolation control, W1b), only the GRPO task vector improves (+0.081) while a norm-matched random vector (-0.450) and the SFT vector (-0.574) fall well below base.
- This telemetry, from millions of clinical-reasoning elements of inpatient notes generated in real hospitals and used daily by clinicians, shows the need for (GRPO + Merge). Over six months the GRPO-only checkpoint terminates cleanly on 98.89% of completions, the remaining 1.1% degenerate outputs clinicians rejected 100% of the time, while the merged model terminates cleanly on 100%, reflecting the necessity for a meaningful merge to obtain a generally useful inpatient reasoning model.
W1b. Is the merge luck or method (merge-isolation control)
As a control we ran for this rebuttal, we varied only the donor task vector at a fixed DELLA configuration, on 358 paired items with identical judge and rubrics (family-dependence in Appendix C.9).
| Donor merged into base | Score | Delta vs base (95% CI) |
|---|---|---|
| GRPO task vector (the paper's merge) | 0.763 | +0.081 [+0.047, +0.115] |
| SFT task vector | 0.108 | -0.574 [-0.616, -0.531] |
| Random, norm-matched permutation of the GRPO vector | 0.232 | -0.450 [-0.500, -0.400] |
| No merge (base) | 0.682 | reference |
- Only the GRPO donor improves, while a norm-matched random vector and the SFT vector both fall well below base. The random control preserves the GRPO vector's magnitudes but carries random circuits, so a generic base-restoration would restore similarly, which it does not. The merge transmits the reasoning structure of the RL update, not generic capability.
- The result is stable across filters (84.25 to 84.95 on Qwen3-8B), so it is a systematic introduction of stable reasoning circuits, not a lucky configuration.
W1c. The Landis-Koch label
Kappa 0.42 is moderate, not substantial, on the Landis-Koch scale. We will correct this in Section 5 wherever it appears.
W1d. Scope of the novelty claim
Our claim is scoped to being the first per-case rubric conditioned on the withheld future of a real patient trajectory, past-verifiable at grading time, and used as both the RL reward and the evaluation metric for inpatient EHR reasoning. The introduction positions this against general-domain rubric-as-reward work (HealthBench, Gunjal, Clinical-R1/CRPO), which is static or per-instance and never conditioned on a patient's downstream trajectory. We will make the scope explicit in the abstract and point to the contribution table in Appendix A.
W1e. The reasoning-distilled transfer result
We will present the DeepSeek-R1-Distill number (11.99) as motivation, not a causal transfer claim. It shows post-training tuned for verifiable math and code rewards does not carry over to open-ended inpatient reasoning, the gap our formulation closes. That model is out of distribution for CLR-POMDP and never saw the per-case rubric reward, so it cannot isolate the reward mechanism from domain shift.
W2a. Why the merge helps the clinical-content axes
An RL update concentrates in a small, high-magnitude subset of the weights (Yuan, Xiangchi, et al. "Behavior Knowledge Merge in Reinforced Agentic Models." arXiv preprint arXiv:2601.13572 (2026)). A filtered merge (DELLA-Merging, Deep et al. 2024; Model Breadcrumbs, Davari and Belilovsky 2024; DARE, Yu et al. 2024) keeps the largest changes and rescales them, incorporating the GRPO update without overwriting broad capabilities.
- The two families respond differently because they start from different places. Qwen3-8B is already reasoning-post-trained, so GRPO amplifies its sparse reasoning circuits and the merge has a broad-spectrum effect on content criteria needing the correct named entity. MedGemma-4B is instruction-tuned with no reasoning training and starts from a low base (27.01), so the merge incorporates the new GRPO reasoning circuits while re-balancing the conversational axes, moving the aggregate less but still practically beneficial (Appendix B.12).
W2b. Table 1 needs a GRPO-only column
We computed the GRPO-only column for the rebuttal.
| External benchmark | base | GRPO-only | merged |
|---|---|---|---|
| DDXPlus (open-set diagnosis) | 43.5 | 48.5 | 48.5 |
| MedMCQA (medical MCQ) | 66.0 | 65.5 | 67.0 |
The recipe produces a gain in two ways, and neither stage is best on its own across tasks. On DDXPlus GRPO is the sole driver (+5.0 over base) and the merge preserves it. On MedMCQA the merge is the driver, since GRPO alone sits just below base (65.5 vs 66.0) and the merge raises it to 67.0. In domain, GRPO-only reaches 77.99 and the merged model 84.95, and the merge alone does nothing without it (W1b).
W2c. Reward-component ablation
Both the training telemetry and a direct ablation attribute the GRPO gain to the outcome-grounded rubric term, not the format and tag scaffolding.
| Reward component | behaviour during training |
|---|---|
| format | standard deviation 0.000 across each prompt's rollout group from step 1 |
| tag | saturates by step ~148 of 3,218 (under 5% of training) |
| rubric | the only component with non-zero within-group variance for over 95% of training |
GRPO's advantage is group-relative, so a component identical across rollouts gives zero gradient, and once format and tag saturate the rubric term drives every update, with the per-axis gains on the three content axes it grades (Completeness +9.20, ContextAwareness +3.32, Accuracy +2.64).
A direct ablation removes the rubric reward with everything else identical.
| MedGemma-4B configuration | Aggregate score |
|---|---|
| Base (no GRPO) | 27.0 |
| GRPO, scaffolding only (rubric reward removed) | 27.5 |
| GRPO, full reward (with per-case rubric) | 53.6 |
The scaffolding-only run sits at 27.5, essentially at the 27.0 base, while the full reward reaches 53.6, so the per-case rubric term drives nearly the entire GRPO gain.
W2d. Scaling and generalization
The 8B scale is set by the partner hospital's on-premise constraints (Section 7, Appendix C.9). We show generality across two very different bases rather than a same-family ladder. An 8B hybrid-reasoning model (Qwen3-8B) and a 4B medically fine-tuned multimodal model (MedGemma-4B) both improve under the identical pipeline, and the ablation above shows the rubric term drives the gain on each. We note same-family GRPO-only scaling to 14B as future work, since one stable GRPO run with a judge in the loop takes on the order of 4,000 H200 GPU-hours, and we ablate the recipe at 4B and 8B across two families.
W2e. RL training-set size and oracle-family circularity
The RL training set is 5,099 admissions with four queries each (about 20.4K QA items), disjoint from the test cohort by admission, a greedy set-cover subset smaller than the 20%-of-remainder test split (7,927 admissions). We will add this in Section 3.
For oracle circularity, a re-grade scores the full test set with the different-family MedGemma-27B judge.
| Model | MedGemma-27B judge (cross-family, full test set) |
|---|---|
| ours | 0.694 |
| GPT-5 | 0.672 |
| Qwen3-8B base | 0.598 |
Our model stays ahead of both references under this different-family judge, by +2.2 over GPT-5 (95% CI [+1.6, +2.7]) and +9.6 over base (95% CI [+9.0, +10.2]). The ordering matches the paper's Qwen3-32B judge.
W3a, W3b, W3c. Clarity fixes
- Overloaded taxonomies. We will lay the four distinct schemes out in one Section-3 table and use one canonical term, "per-case rubric", throughout. They are the five grading axes from HealthBench, the four action spaces, the seven themes the oracle draws on, and the safety-weighted critical-accuracy subset. The synonyms "adaptive", "per-case", "outcome-aware", and "trajectory-conditioned" all name one object.
- The three agreement numbers, easy to conflate. Kappa 0.702 is physician-physician inter-rater reliability on rubric criteria, kappa 0.42 is Grounded-Judge-to-clinician agreement, and 0.034 and 0.051 are human-human A/B preference agreements, low because preferences were near-unanimous rather than because raters disagreed. Body labels (R1, R2, R3) and appendix labels (Phase-1, Phase-2) denote the same events, R1 equal to Phase 2. The Grounded Judge's clinician agreement (about 0.42) is similar to GPT-4.1 and GPT-5, so the grading signal is not an idiosyncrasy of our oracle.
- Figure 2 will be made self-consistent with the text, with one prefix per base family, "Breadcrumbs" spelled out, "GRPO" kept in every merge label, "DELLA-Linear" used consistently, and a larger font.
In closing, the contribution is the formulation, and the weight-space merge is a required stage of it, not a detachable, lucky add-on. The merge behaves differently across models because the two bases start from different places, not because it is unreliable, and it cannot create ability on its own, since merging a base with itself returns the base (W1b). We have run every ablation the reviewer suggested except same-family scaling, and are glad to run further analyses within the discussion window.
Follow-up detail for Reviewer VUsr
Our main response is capped at 10k characters. This follow-up carries the supporting detail we could not fit there. The merge concern is the reviewer's central one, so we answer it in full here.
General comment on the utility of model merging
The reviewer's central concern is that an off-the-shelf weight-space merge, which is prior work, delivers considerable gain, so the win is not attributable to our formulation. We answer this in four parts, using the controls the reviewer requested.
-
The merge is a required stage of one formulation, not a detachable prior-work add-on. Our contribution is the end-to-end formulation, namely the CLR-POMDP problem setting, the outcome-grounded and clinician-validated reward, and the post-training recipe as a whole, of which the merge is one stage. Outcome-grounded GRPO improves the content axes while eroding some general ability, and the merge recovers that ability without losing the content gains. Treating the merge as a component to be set aside mischaracterizes how state-of-the-art LLMs and deployed clinical models are built using model merging (Nemotron 3 Ultra [1], MediPhi [2]).
-
Merged model exceeding both parents (base and GRPO post-trained) on the content axes is an expected property of merging. Merging fine-tuned models is documented to produce synergistic capabilities that surpass either parent [3, 4]. This is exactly the pattern the reviewer flags on MedGemma-4B Accuracy, where the merged model reaches 80.77 versus 66.57 for the base and 69.21 for GRPO-only. In our case the merge recombines the GRPO reasoning circuits with the base's lexical breadth that focused RL rollouts had narrowed, so the content axes that need the correct named entity, a drug or an anatomic site, recover above both parents.
-
The gain is not generic base-restoration, it amplifies our RL signal. We ran the additional experiments, varying only the donor task vector at a fixed DELLA configuration on 358 paired items with identical judge and rubrics.
| Donor merged into base | Score | Delta vs base (95% CI) |
|---|---|---|
| GRPO task vector (the paper's merge) | 0.763 | +0.081 [+0.047, +0.115] |
| SFT task vector | 0.108 | -0.574 [-0.616, -0.531] |
| Random, norm-matched permutation of the GRPO vector | 0.232 | -0.450 [-0.500, -0.400] |
| No merge (base) | 0.682 | reference |
Only the GRPO donor improves (+0.081 over base), while a norm-matched random vector (-0.450) and the SFT vector (-0.574) both fall well below base, and merging the base with itself returns the base. Merging the SFT donor or a random task vector does not restore performance, so the roughly 7-point gain is not generic base-restoration, it amplifies the reasoning structure the GRPO step wrote into the weights. This is consistent with Yuan et al. [5], who show that an RL update concentrates in a small, high-magnitude subset of weights that a filtered merge (DELLA [6], Breadcrumbs [7], DARE [8]) transmits back to the base model.
-
The family-dependence is method, not luck, because the two bases start from different places. The result is stable across filters, with DELLA, Breadcrumbs, and DARE variants within 0.7 points (84.25 to 84.95 on Qwen3-8B), which is systematic rather than a lucky configuration. Qwen3-8B is already reasoning-post-trained, so GRPO amplifies its existing sparse reasoning circuits and the merge has a broad-spectrum effect. MedGemma-4B is instruction-tuned with no reasoning training and starts from a low base (27.01), where new reasoning circuits form during GRPO. On MedGemma-4B the merge still transmits the content gains the reviewer notes (Accuracy +7.48, Completeness +11.32), and the aggregate is flat (63.40 to 63.35) only because the low-base instruction-tuned model cannot hold both the new content circuits and its conversational axes at once, so those axes drop (Communication -16.22, InstructionFollowing -5.60). The content-axis transfer is the same mechanism on both families.
-
The merge is also a practical necessity, not an enhancement. Over six months of hospital deployment, spanning millions of clinical-reasoning elements of inpatient notes used daily by clinicians, the GRPO-only checkpoint terminates cleanly on 98.89% of completions, with the remaining 1.1% being degenerate over-long outputs that clinicians rejected 100% of the time, while the merged model terminates cleanly on 100%. This reflects the necessity for a meaningful merge to obtain a generally useful inpatient reasoning model.
References
[1] Blakeman, Aaron, et al. "Nemotron 3 Ultra: Open, Efficient Mixture-of-Experts Hybrid Mamba-Transformer Model for Agentic Reasoning." arXiv preprint arXiv:2606.15007 (2026).
[2] Corbeil, J.-P., Dada, A., Attendu, J.-M., Ben Abacha, A., Sordoni, A., Caccia, L., Beaulieu, F., Lin, T., Kleesiek, J., and Vozila, P. A Modular Approach for Clinical SLMs Driven by Synthetic Data with Pre-Instruction Tuning, Model Merging, and Clinical-Tasks Alignment. In Proceedings of the 63rd Annual Meeting of the Association for Computational Linguistics (ACL), pages 19352-19374, 2025.
[3] Lu, W., Luu, R. K., and Buehler, M. J. Fine-tuning large language models for domain adaptation: Exploration of training strategies, scaling, model merging and synergistic capabilities. npj Computational Materials, 2025 (arXiv:2409.03444, 2024).
[4] Akiba, T., Shing, M., Tang, Y., Sun, Q., and Ha, D. Evolutionary optimization of model merging recipes. Nature Machine Intelligence, 7:195-204, 2025.
[5] Yuan, X., Shi, D., Zhang, C., Liu, Z., Yao, S., Vosoughi, S., and Lee, W. Behavior Knowledge Merge in Reinforced Agentic Models. arXiv:2601.13572, 2026.
[6] Deep, P. T., Bhardwaj, R., and Poria, S. DELLA-Merging: Reducing Interference in Model Merging through Magnitude-Based Sampling. arXiv:2406.11617, 2024.
[7] Davari, M., and Belilovsky, E. Model Breadcrumbs: Scaling Multi-Task Model Merging with Sparse Masks. In European Conference on Computer Vision (ECCV), 2024 (arXiv:2312.06795).
[8] Yu, L., Yu, B., Yu, H., Huang, F., and Li, Y. Language Models are Super Mario: Absorbing Abilities from Homologous Models as a Free Lunch. In Proceedings of the International Conference on Machine Learning (ICML), 2024.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We thank the Area Chair for their review and and for indicating that a rebuttal addressing the stated issues could improve the assessment. We have addressed every concern with new results and discussions. This response is the global summary, and the per-reviewer replies contain the full detail.
Table continued in the next comment.