potentialpaper

Hypnos: Learning Generalisable Representations of Sleep Physiology via Next-Token Prediction

Jonathan F. Carter, Lionel Tarassenko

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. Next-token prediction over discrete physiological tokens scales cleanly to multi-modal sleep foundation models, producing Hypnos, which matches or beats prior foundation models and strong supervised baselines.

Abstract. Foundation models offer a promising route to compress multi-modal physiological signals into compact representations of human health, with broad applications across sleep medicine, cardiology, neurology and other healthcare domains. Existing models have typically been trained with masked-reconstruction or contrastive objectives. However, masked reconstruction may be poorly suited to the stochastic nature of these signals, while contrastive approaches rely on positive-pair definitions despite the semantic invariances of physiological signals being poorly understood. In this work, we show that next-token prediction is a simple and scalable alternative. We develop Hypnos, a multi-modal sleep foundation model trained using eight different sensing modalities (e.g. EEG, ECG, respiratory signals) drawn from over 20{,}000 overnight polysomnography recordings. We tokenize each modality into streams of discrete tokens using residual vector quantization, then train a large auto-regressive RQ-Transformer to jointly predict the next token across all modalities in parallel. After training, Hypnos can be applied to continuous streams of sensor data from any subset of supported modalities, generating embeddings for downstream tasks. Hypnos significantly outperforms existing foundation models on most benchmarks evaluated. In sleep stage classification, we match the performance of strong supervised baselines on held-out test sets whilst using 100×100\times less labelled data. Hypnos even generalises beyond sleep recordings, surpassing a dedicated ECG foundation model at detecting atrial fibrillation. Our results demonstrate that auto-regressive token modelling is a strong self-supervised approach for representation learning from multi-modal physiological signals.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
4 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:48 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The paper propose a next-token-prediction sleep foundation model with a Chinese Restaurant Process modality-masking scheme, evaluated across diverse downstream tasks and model scales. Reviewers agreed the empirical results are strong, where the model outperforms SleepFM and OSF on most tasks with appropriate statistical testing, the model is robust to missing modalities, three model sizes are provided for different compute budgets, and the supplementary materials are thorough and support reproducibility.

However, all three reviewers converge on the same core gap: the paper’s central claims about why NTP works are asserted, not isolated experimentally. The following points must be addressed especially:

  • All three reviews independently note that the comparison against SleepFM (contrastive) and OSF (self-distillation) confounds the training objective with backbone, context length, and aggregation strategy. Run a controlled ablation that fixes the backbone and tokenization and swaps NTP for a masked-reconstruction objective on the same discrete tokens. Without this, the paper’s motivating claim, that NTP handles the stochastic nature of physiological signals better than MAE/CL, is not supported by the current evidence.

  • Missing-modality robustness via masking is not new, so CRP’s specific contribution is the grouping strategy. Compare against a simpler partition sampler to establish whether CRP’s inductive bias is actually doing work, given its defining properties are not obviously suited to a small fixed set of modalities.

  • Report parameter counts and/or compute for Hypnos and baselines, and clarify whether reported gains come from a better learned representation or simply a larger model. At minimum, state clearly that the current results show “this model scales” and temper any claim that NTP scales better than alternatives, unless a compute-matched comparison is added.

Final justification

The paper's large-scale empirical results are strong and reproducible, however the rebuttal's own ablations show the central mechanistic claims did not hold: NTP and masked-token prediction learn similarly effective representations, CRP shows no advantage over random dropout, and alternative objectives scale comparably. The authors ran these falsifying tests themselves and reported them honestly, which is a mark in the paper's favor even as it narrows the contribution.

Recommending accept (poster), conditional on the camera-ready reframing the paper as a large-scale empirical demonstration of autoregressive modeling for multimodal PSG, not evidence that NTP or CRP are uniquely responsible for the gains.

Area Chair A2d8 · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The paper propose a next-token-prediction sleep foundation model with a Chinese Restaurant Process modality-masking scheme, evaluated across diverse downstream tasks and model scales. Reviewers agreed the empirical results are strong, where the model outperforms SleepFM and OSF on most tasks with appropriate statistical testing, the model is robust to missing modalities, three model sizes are provided for different compute budgets, and the supplementary materials are thorough and support reproducibility.

However, all three reviewers converge on the same core gap: the paper’s central claims about why NTP works are asserted, not isolated experimentally. The following points must be addressed especially:

  • All three reviews independently note that the comparison against SleepFM (contrastive) and OSF (self-distillation) confounds the training objective with backbone, context length, and aggregation strategy. Run a controlled ablation that fixes the backbone and tokenization and swaps NTP for a masked-reconstruction objective on the same discrete tokens. Without this, the paper’s motivating claim, that NTP handles the stochastic nature of physiological signals better than MAE/CL, is not supported by the current evidence.

  • Missing-modality robustness via masking is not new, so CRP’s specific contribution is the grouping strategy. Compare against a simpler partition sampler to establish whether CRP’s inductive bias is actually doing work, given its defining properties are not obviously suited to a small fixed set of modalities.

  • Report parameter counts and/or compute for Hypnos and baselines, and clarify whether reported gains come from a better learned representation or simply a larger model. At minimum, state clearly that the current results show “this model scales” and temper any claim that NTP scales better than alternatives, unless a compute-matched comparison is added.

Final justification

The paper's large-scale empirical results are strong and reproducible, however the rebuttal's own ablations show the central mechanistic claims did not hold: NTP and masked-token prediction learn similarly effective representations, CRP shows no advantage over random dropout, and alternative objectives scale comparably. The authors ran these falsifying tests themselves and reported them honestly, which is a mark in the paper's favor even as it narrows the contribution.

Recommending accept (poster), conditional on the camera-ready reframing the paper as a large-scale empirical demonstration of autoregressive modeling for multimodal PSG, not evidence that NTP or CRP are uniquely responsible for the gains.

Reviewer wCocOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
2/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper introduces Hypnos, a multi-modal foundation model for overnight polysomnography (PSG) trained with a next-token prediction objective. Each of the eight physiological channels is independently tokenized using a residual vector quantization tokenizer, and then a RQ-Transformer is trained to autoregressively predict the next residual token jointly across all modalities. To support inference on arbitrary sensor subsets, the authors introduce a group-masking scheme in which modalities are randomly partitioned into attention groups, sampled from a Chinese Restaurant Process, per training example.

The model is pre-trained on over 20k PSG recordings from 9 public datasets. Evaluation uses frozen-encoder linear/MLP probes on sleep staging, arousal detection, apnea detection, and oxygen desaturation, across in-domain and held-out cohorts. The proposed Hypnos matches or exceeds prior sleep foundation models (SleepFM, OSF) and strong supervised baselines (U-Sleep, SleepTransformer, YASA) on most tasks. Empirical results also show that both next-token perplexity and downstream probe perfomance improve with model scale, and that the model retains useful performance under restricted-sensor configurations.

Strengths and weaknesses

Strengths:

  • Strong empirical results against relevant baselines. Hypnos embeddings outperforms the SOTA sleep foundation models, SleepFM and OSF, as well as task-specific supervised baselines on most of the datasets and tasks, with appropriate statistical testing showing significance. This demonstrates the proposed model produces high-quality, general-purpose sleep representations.

  • Thorough supplementary materials. The provided details in the appendix supports the reproducibility of the paper. It provides full prepocessing details, complete tokenizer and training hyperparameters, and compute accounting. It also contains substantive supporting experiments, including ablation of hyperparameter choices as well as scaling and stability analysis.

Weakness:

  • The paper's central claim about Next-Token Prediction is not verified. The motivation of the proposed method is that masked reconstruction objective is "poorly suited to the stochastic nature" of physiological signals and contrastive objective leave semantic invariance of physiological signals being poorly understood, whereas next-token prediction handles stochasticity gracefully. Yet no experiment isolates the training objective. The comparison agains baselines (e.g., SleepFM is contrastive and OSF is self-distillation) confound the objective with architecture, tokenization, model scale, context length, aggregation strategy, etc. The controlled experiments, e.g., hold other parts fixed and swap the next-token-prediction for a masked-reconstruction objective on the same discrete tokens, are not run. There's also no measurement showing that next-token prediction capture stochastic structure of physiological signals better than other alternatives. Thus, although the empirical results show that Hypnos is a good model, the stated claim about the advantage of next-token prediction is not supported.

  • Limited originality, with the novel component under-justified. The training and design recipe of the next-token prediction framework is adopted closely from prior works. The principal original component is therefore the grouped modality-masking scheme. However, group masking it not itself a new idea, prior work like LSM-2, wav2sleep, OSF already achieves missing-modality robustness through attention masking, zero-padding, or random channel dropout, thus the specific novelty here reduces to how the groups are samples. However, the Chinese Restaurant Process is not a obviously appropriate choice for partitioning a small, fixed set of 8 modalities. Its defining properties (e.g., unbounded cluster numbers, exchangeability) are not exploited in the sleep foundation model setting. There's no comparison agains simpler partition samplers, e.g., drawing a group count and then assigning modalities, so the reader cannot tell whether CRP's inductive bias matters at all. More importantly, the paper does not offer insights into how physiological modalities should be grouped, e.g., which sensor subsets are informative, or the interaction within which group are important for clinical deployment. The originality thus rests on a design choice that is neither motivated nor empirically validated.

Questions
  1. Could you prove empirical results supporting that next-token prediction performs better than alternative objectives, e.g., masked-token-prediction, or capture the stochastic nature of physiological signals better than alternatives?

  2. Could you validate the choice of the CRP grouping strategies, e.g., compare to simpler partition sampler with the architecture fixed?

  3. What is the rationale for specific distribution over modality groupings the CRP induces (with α=1.0\alpha=1.0)? How does it match clinically deployed sensor configuration?

  4. Do you have explanations about why some baseline results are strikingly low for sleep stage, e.g., SleepFM got 0.418 on DOD-H and with MLP probe got even worse (0.370)?

Limitations

yes

Final justification

The rebuttal reveals some of the original methodological claims were too strong: NTP and masked-token prediction learn similarly effective representations, CRP offers no measured advantage over random dropout, and alternative pretraining methods are also scalable.

The paper’s contribution should therefore be framed as a strong large-scale demonstration of autoregressive token modeling for multimodal PSG, not as evidence that NTP uniquely enables scaling or that CRP uniquely enables missing-modality robustness. The generative capability remains only lightly evaluated and should be presented as a promising property rather than a fully validated contribution.

I retain my slightly positive rating because the work provides strong large-scale empirical demonstration. I would also consider rejection defensible if the AC places greater weight on the limited methodological novelty, the negative results for the claimed CRP contribution, or the fact that several central claims required substantial revision during rebuttal.

Formatting concerns

None

3 comments
Authors · CommentOpenReview ↗

Thank you for your thorough review of our submission. We are grateful for your acknowledgement of our strong empirical results and thorough supplementary materials. Below we have addressed specific feedback from your review, linking to our central response for points that have also been raised by other reviewers.

“Limited originality”

We believe that the key contributions of our work lie in what it establishes, rather than simply the number of new components. Our work shows that the simple objective of predicting the next token can lead to state-of-the-art performance, without additional loss components (e.g. custom contrastive losses) or auxiliary training machinery (student-teacher, EMA, etc.). Using Hypnos and 1% of labels matches the strong supervised baseline of U-Sleep in sleep staging.

In addition to SOTA performance, Hypnos has several practical advantages that we believe are of interest to the community including per-second embeddings and whole night processing with causal convolutions and causal attention, enabling streaming inference for e.g. real-time sleep staging and arousal detection.

“no measurement showing that next-token prediction capture stochastic structure of physiological signals better than other alternatives”

Prior ML work such as I-JEPA has long-made the case that MAE expends model capacity on unpredictable low-level detail. We didn’t mean to imply that only NTP can capture stochastic structure, we only highlight this as a potential advantage of NTP over MAE (see Line 73 onwards). On L82 we suggest that continuous diffusion is a promising alternative approach. More broadly, we believe that variational latent space predictive objectives (discrete token prediction, latent diffusion, Var-JEPA, etc.) are all more promising directions than MAE in the physiological signal domain. We will update the paper with generative examples that demonstrate the ability of Hypnos to capture stochastic structure. Please see the 'Generative capability' section of our central response for more details.

“Could you prove empirical results supporting that next-token prediction performs better than alternative objectives”

Please see the ’Hypnos vs baselines’ and ‘NTP vs alternatives’ section of our central response. We provide more controlled experiments against existing baselines (OSF and sleep2vec), and additional experiments comparing with non-autoregressive masked token prediction. These results show that even Hypnos-Tiny often outperforms the largest OSF and sleep2vec variants evaluated.

“What is the rationale for specific distribution over modality groupings the CRP induces (with )? How does it match clinically deployed sensor configuration?”

CRP was used as a convenient method to sample diverse groups of modalities during training whilst using all available tokens in each forward pass. We chose alpha=1 as a sensible default to ensure all group sizes M=1 to M=8 had non-negligible probability mass during training, but we did not tune alpha, and we did not bias sampling towards particular sensor configurations.

We performed new experiments investigating the effect of training-time masking, comparing CRP with random channel dropout (p=0.5). Summary results are provided in the ‘Modality masking’ section of our central response. These show that CRP and random dropout achieve comparable results across restricted sensor configurations. CRP leads to a 20x exposure to single-channel (M=1) data during training. However, performance using single-lead EEG (M=1) was indistinguishable from random dropout. This is a valuable result, indicating the specific training-time masking strategy is unimportant and may not need to be tailored to a specific, downstream clinical configuration. Please see the ‘Modality masking’ section of our central response for more details.

“why some baseline results are strikingly low [...], e.g., SleepFM got 0.418 on DOD-H and with MLP probe got even worse (0.370)?”

It is common in the sleep staging literature that models (particularly those using EEG) fail to generalise to held-out test sites because of issues like amplifier gain and channel referencing. We originally reported performance using the open-source SleepFM model weights. We have also now re-implemented SleepFM using the same splits and pre-processing steps as Hypnos. Our re-implementation obtained better performance than the open-source weights, though Hypnos still performs significantly better e.g. see below. We will update all tables to use this stronger baseline in the paper.

Re-trained SleepFM vs Hypnos. Held-out performance w/ MLP probe.

Model Staging AUROC Staging AUPRC Arousal AUROC Arousal AUPRC Apnoea AUROC Apnoea AUPRC Desat. AUROC Desat. AUPRC
Re-trained SleepFM 0.952 0.718 0.883 0.698 0.777 0.396 0.731 0.714
Hypnos 0.973 0.796 0.934 0.808 0.795 0.418 0.767 0.755
Reviewer wCoc · CommentOpenReview ↗

Thanks the authors for the response.

The rebuttal substantially improves the empirical evaluation, but the results do not validate the claimed superiority of NTP or the contribution of CRP. The remaining contribution is a strong large-scale empirical demonstration of autoregressive token modeling for multimodal PSG, with broad downstream performance and practical streaming capabilities. I therefore retain my borderline-accept rating, conditional on the final paper clearly tempering its methodological claims and presenting the negative ablation results.

Authors · CommentOpenReview ↗

Thanks for confirming your score. We confirm the following changes to the final paper:

Tempering methodological claims. We will make it clearer that our critique of masked reconstruction relates to input-space reconstruction and that the advantage of NTP over MTP is practical, e.g. real-time deployments, AR generative capability, tempering claims about the specific superiority of NTP for downstream representation quality.

Presenting negative ablation results. Both ablations will appear in the final paper: (i) the objective comparison (next-token vs. masked-token prediction, with the tokenizer and backbone fixed); and (ii) the modality-masking ablation, highlighting that CRP and random channel dropout are indistinguishable despite a ~20× difference in single-channel exposure during training, alongside the α→0 and α→∞ endpoints.

We are grateful for your feedback, which has materially improved the paper!

Reviewer V7ohOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes Hypnos, a sleep foundation model pretrained via next-token prediction. Eight physiological channels (EEG, EOG, EMG, ECG, and abdominal/thoracic respiratory effort) are each tokenized with residual vector quantization (RVQ), and an RQ-Transformer (a temporal backbone plus a depth transformer) jointly predicts the next token across all modalities. A modality-masking strategy based on the Chinese Restaurant Process (CRP) is introduced to improve robustness to missing modalities. The model is pretrained on roughly 20,000 overnight recordings and evaluated on sleep staging, cortical arousal detection, apnoea detection, and oxygen desaturation detection, where it outperforms prior sleep foundation models. It also shows fast adaptation under label scarcity and robustness to missing modalities.

Strengths and weaknesses

Strengths

  • The motivation for next-token prediction pretraining is well-argued and timely, and the objective translates into strong downstream performance.
  • The model is robust to missing modalities, which the authors attribute to the CRP modality-masking strategy applied during pretraining.
  • Three model sizes (Hypnos-Tiny/Small/Base) are pretrained and evaluated, allowing users to select a model according to their compute budget.

Weaknesses

  • Next-token prediction pretraining is more computation-expensive than alternatives such as contrastive learning or masked autoencoding. This added cost would be justified if the model's generative capability were exploited, but nearly all downstream tasks are classification or regression. For instance, the authors use arrhythmia as an illustrative example to motivate NTP (Figure 1), yet no experiment actually evaluates this generative/distributional property. The strength that motivates the method is therefore never directly demonstrated.
  • The paper claims that next-token prediction enables effective model scaling, but provides no evidence that competing objectives (contrastive learning, masked reconstruction) fail to scale. Without this, the scaling result supports only "this model scales" but not that “this model scales better”
  • Assuming that other objectives also scale, the comparison would be incomplete without matching model size and compute across methods. Reporting parameter counts and/or compute for Hypnos and the baselines would clarify whether the performance gains stem from a better learned representation or simply from a larger model.
Questions
  • Can the authors provide direct evidence that NTP scales more efficiently than alternative pretraining objectives? This would substantiate the central claim in the title.
  • How is “significantly better” defined in Table 3 and 4? Does it have any criteria for this? Was Wilcoxon signed rank test used for this? Please state the test, the correction for multiple comparisons, and the significance threshold explicitly in the table captions.
  • More details of additional sleep analysis should be provided. For example, is oxygen desaturation labeled at the epoch level or the token level? How are positive class defined for each task?
  • Including (or at least discussing) more sleep foundation models would strengthen the paper. For example, Sleep2vec (https://openreview.net/forum?id=DDXhRN66eV) or SleepMaMi(https://icml.cc/virtual/2026/poster/62696) also provided alternative pretraining strategies for PSG understanding.
Limitations

yes

Final justification

All my concerns were addressed during the rebuttal. Particularly, the authors provided the additional experiments on compute-efficiency of NTP to alternative pretraining strategies (CL, MAE) and confirmed to include discussion on more recent sleep foundation models.

Formatting concerns

No formatting issues

5 comments
Authors · CommentOpenReview ↗

Thank you for your thorough review of our work. We are pleased that you found the motivation for our work well-argued and timely, and for acknowledging the strength of our results. Below we have addressed specific feedback from your review, linking to our central response for points that have also been raised by other reviewers.

“cost would be justified if the model's generative capability were exploited”, “The strength that motivates the method is therefore never directly demonstrated.”

You are correct that the generative capabilities of Hypnos are presently unexplored. Our original focus in this work was representation learning. The fact that Hypnos unifies generative modelling and representation learning into a single model is another advantage over existing sleep foundation models which we undersold in our original submission and we will highlight this capability in the final paper. Very recent work has explored utilising generative models for e.g. synthetic data [1], which Hypnos could be well-suited to. We plan to include additional examples that demonstrate the generative capabilities of Hypnos, and highlight the potential of this direction for future work. Please see the ‘Generative capability’ section of our central response for more details.

[1] Z. Shuai, Z. Xu, Y. Wu, S. Li, T. Li, and Y. Yang, ‘Signal or Noise? Understanding Generative Models for Real-World Sensor Time Series’, arXiv.org. Available: https://arxiv.org/abs/2607.04245v1

“Including (or at least discussing) more sleep foundation models would strengthen the paper.”

Thank you for bringing sleep2vec and SleepMaMi to our attention. We will add both papers to the discussion. We have also fully re-implemented sleep2vec using the same pre-processing pipelines and dataset splits as Hypnos. Additional new model-scaling results against sleep2vec are provided in the ‘Hypnos vs baselines’ section of our central response. Full results including missing modality robustness will be added to the final paper. We have found that Hypnos outperforms sleep2vec across all downstream tasks and modality configurations with statistical significance. We will primarily report performance against sleep2vec-large in the final paper, which uses a larger Transformer backbone than Hypnos, since that is the variant reported in the original sleep2vec paper.

“Reporting parameter counts and/or compute for Hypnos and the baselines would clarify whether the performance gains stem from a better learned representation or simply from a larger model”

“Can the authors provide direct evidence that NTP scales more efficiently than alternative pretraining objectives?”

We have performed additional model scaling experiments comparing Hypnos with OSF and sleep2vec, using matched Transformer backbones, and re-training both variants on identical dataset splits and pre-processing splits as Hypnos. These results show that Hypnos-Tiny often outperforms the largest OSF and sleep2vec variants evaluated. Please see the 'Hypnos vs. baselines' section of our central response for more details.

We have also launched experiments scaling the compute of both OSF and sleep2vec, scaling the number of training steps and/or the batch size by 4x with the LR tuned. Initial results indicate that neither approach shows significant improvement with additional compute at fixed model/data size. We will report final results as soon as training/evaluation completes in the next 24-48h. These experiments are detailed in the Hypnos vs baselines section of our central response.

“How is “significantly better” defined in Table 3 and 4 [...] Please state the test, the correction for multiple comparisons, and the significance threshold explicitly in the table captions.”

This is detailed in Section 4.1 (Line 231-232). We used a Wilcoxon signed-rank test across subjects to assess statistical significance, with Benjamini-Hochberg FDR correction (q < 0.05) for multiple comparisons. We will make this clearer in the captions.

“More details of additional sleep analysis should be provided. [...] Is oxygen desaturation labeled at the epoch level?”

This is described on Lines 207-211. Different foundation models produce embeddings at different timescales. To simplify comparison, we formulated downstream tasks as classification over 30-second epochs. An epoch is marked as a positive for oxygen desaturation if a desaturation event has any overlap with that epoch. Another advantage of Hypnos over existing sleep foundation models is that it produces per-second embeddings with causal information flow for higher resolution, real-time event detection. We will add additional evaluations to the Appendix demonstrating Hypnos’ effectiveness of real-time 1 Hz event detection for apnoea (e.g. AUPRC=0.78 on SHHS) and arousal detection (e.g. AUPRC=0.70 on SHHS), something other sleep foundation models do not currently support.

Reviewer V7oh · CommentOpenReview ↗

Thank you for the clarification. I will wait for the new experimental results to come out and consider my rating again.

Authors · CommentOpenReview ↗

Thanks again for your feedback, and for your patience as we performed new experiments to address your concerns and strengthen the findings of our work.

Using comparable compute, Hypnos still outperforms OSF across evaluations at different model scales.

Model Transformer Backbone Enc (M) Compute (FLOPs) Staging κ Apnoea AUC Arousal AUC Desat AUC
OSF-tiny 12L/192d 5.4 7.5e18 0.709 0.761 0.904 0.704
hypnos-tiny 12L/192d 19.7 8.3e18 0.771 0.780 0.912 0.736
OSF-small 12L/384d 21.4 2.5e19 0.766 0.768 0.909 0.728
hypnos-small 12L/384d 53.6 2.6e19 0.793 0.786 0.918 0.756
OSF-base 12L/768d 85.3 9.3e19 0.785 0.791 0.918 0.738
hypnos-base 12L/768d 163.8 1.0e20 0.815 0.808 0.934 0.767

Additionally, we tried scaled up the compute of sleep2vec (ViT-Base) beyond the original training recipe via the batch size (with a tuned LR) and via training steps, including training up to 80k steps, 4x the original paper recipe. This resulted in only a minor improvement in performance (e.g. MROS MLP Cohen’s kappa 0.757 -> 0.765), still lower than Hypnos-Tiny, with probing performance plateauing around 35k steps into training. We will add these additional experiments to the final paper, which further strengthen the evidence that Hypnos can provide improved representation quality at comparable model size.

Model Transformer Backbone Enc (M) Staging κ Apnoea AUC Arousal AUC Desat AUC
sleep2vec-tiny 12L/192d 19.0 0.679 0.723 0.829 0.700
hypnos-tiny 12L/192d 19.7 0.771 0.780 0.912 0.736
sleep2vec-small 12L/384d 49.3 0.732 0.748 0.859 0.710
hypnos-small 12L/384d 53.6 0.793 0.786 0.918 0.756
sleep2vec-medium 12L/768d 144.1 0.757 0.765 0.873 0.733
hypnos-base 12L/768d 163.8 0.815 0.808 0.934 0.767
sleep2vec-large 16L/1024d 282.8 0.766 0.777 0.883 0.750

We hope this clarifies your original concerns, and would be very grateful if you would consider raising your score in light of these strengthened findings.

Reviewer y6X9OpenReview ↗
Rating
4/6
Confidence
3/5
Quality
2/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper introduces Hypnos, a multimodal sleep foundation model pretrained with a next-token-prediction (NTP) objective over residual vector quantization (RVQ) tokens, using over 20k overnight PSG recordings. Each channel and timestep is tokenized with RVQ, passed through temporal and modality attention, and followed by a depth transformer for NTP. After pretraining, the temporal transformer representation is used with linear/MLP probing for downstream tasks such as sleep staging, arousal, apnoea, and desaturation detection. To handle missing modalities common in real-world recordings, Hypnos employs a Chinese Restaurant Process (CRP) based modality masking strategy. Empirically, Hypnos matches or exceeds prior foundation models and supervised baselines on sleep staging, outperforms prior foundation models on arousal, apnoea, and desaturation detection, shows strong few-shot transfer, and remains robust under missing-modality settings.

Strengths and weaknesses

Strengths

  • NTP is a well-motivated learning objective for stochastic physiological signals, where prior sleep foundation models are mostly trained with MAE or CL objectives. Strong downstream performance also suggests that the learned representations under NTP are informative. The authors provide strong empirical results across diverse tasks and large-scale data. Hypnos also shows strong few-shot performance, and is robust to missing modalities.

Weaknesses

Major Weaknesses

  • The central claim that NTP is superior to MAE/CL for stochastic signals is not supported by isolated evidence. This claim is supported only with an end-to-end performance comparison with SleepFM/OSF. Thus, this would be better supported by ablation experiments that isolate the effect of NTP by varying the learning objective while fixing the backbone (e.g., NTP vs masked token prediction). Furthermore, one of the core

motivations for NTP is long range modeling, but all main tasks are evaluated on 30s epochs with fixed context length. The only supporting evidence (Appendix B.3) is validation-only and unimodal. The robustness results (Table 5) are strong, but the necessity of CRP is weakly established. Ablation studies against simpler alternatives (zero-masking, channel dropout) are required to show CRP is a necessary design that improves robustness or downstream performance.

Moderate Weakness

  • The paper criticizes CL’s objectives as human-imposed bias, but tokenization also has its own assumptions since it discretizes a continuous signal into tokens. Whether such discretization is appropriate for physiological signals is a design choice that is not discussed. Discussing this assumption explicitly would strengthen the paper.
  • These two concerns (objective isolation, CRP necessity) are my main reasons for the current score; I would be willing to raise it if they are addressed.
  • A recent sleep foundation model [1] is missed in the manuscript.

[1] K. Park, et al., “ SleepMaMi: A Universal Sleep Foundation Model for Integrating Macro- and Micro-structures ,” ICML 2026 (https://arxiv.org/abs/2602.07628).

Questions

Most of my questions correspond to the weaknesses above:

  • Can you isolate the objective (NTP vs. masked token prediction) with tokenizer/backbone fixed?
  • (W1)Does CRP outperform simpler masking beyond efficiency?
  • (W2)How do you view the assumption introduced by discretizing a continuous signal into tokens?
Limitations

See the weaknesses.

Final justification

The rebuttal has successfully addressed my primary concerns. I will raise my score.

Formatting concerns

NA

6 comments
Authors · CommentOpenReview ↗

Thank you for your thorough review of our work. We are pleased that you found our direction of NTP well-motivated, and grateful for your acknowledgement of the strength of our empirical results. Below we have addressed specific comments in your review. We would be very grateful for further feedback, and if you would consider updating your score in light of our response.

“The central claim that NTP is superior to MAE/CL for stochastic signals is not supported by isolated evidence”

We have performed new controlled experiments comparing Hypnos with OSF (DINO) and sleep2vec (CL) under identical dataset splits and pre-processing steps across matched Transformer backbones. These are described in the 'Hypnos vs baselines' section of our central response (part 2). We find that Hypnos-Tiny often outperforms the largest variants of both baselines, providing stronger evidence to the efficacy of our approach.

We are also in the process of running isolated experiments comparing Hypnos with MAE across model scales. To further isolate the learning objective, these experiments are being conducted with unimodal EEG data, and will be compared with our unimodal Hypnos models described in Appendix B. We will report the results of these experiments as soon as they are completed in the next 24-48h.

“Can you isolate the objective (NTP vs. masked token prediction) with tokenizer/backbone fixed?”

Please see the section ‘NTP vs alternatives’ of our central response (part 1). Next token prediction is a specific form of masked token prediction. We have run new experiments that indicate BERT-style bi-directional masked-token modelling achieves similar performance to NTP. However, NTP has practical advantages: it allows efficient, sequential updates of new embeddings for real-time use-cases (via KV-caching), and a generative model for auto-regressive forecasting.

“(W1) Does CRP outperform simpler masking beyond efficiency?”

Our original motivation for CRP was to give a convenient single knob to interpolate between using a single group (α → 0, G=1) and fully independent (α → ∞, G=M ), i.e. no cross-modal fusion during training. We performed new experiments investigating the effect of training-time masking, comparing CRP with random channel dropout (p=0.5). Summary results are provided in the ‘Modality masking’ section of our central response. Full results across all restricted modality configurations will be added to the final paper. Despite CRP giving 20x exposure to single-channel (M=1) data during training, CRP and random dropout achieve comparable inference-time robustness across restricted sensor configurations. For example, sleep staging performance using single-lead EEG (M=1) was similar to random dropout (0.773 vs CRP=0.774 on SHHS). This indicates the specific training-time masking strategy is less important and may not need to be tailored to a specific, downstream clinical configuration. We will temper specific claims around CRP. For example, on Line 55 we will remove mention of ‘novel masking strategy’ to avoid giving the impression that CRP specifically enables robustness. Please see the ‘Modality masking’ section of our central response for more details.

“(W2) How do you view the assumption introduced by discretizing a continuous signal into tokens?”

Discrete tokenization has been successfully used in the audio domain for many years. Sensor data already has a finite sampling rate, finite precision (ADC) and the effective resolution is further limited by the sensor noise floor. Therefore we think that discrete tokenization is a very reasonable (and minimal) design bias. We chose a 1-second tokenization for the convenience of 1 Hz embeddings. In the Appendix, we run unimodal experiments for ECG and EEG varying the tokenization length with fixed tokenizer capacity. SNR decreases with tokenization length, but performance remains stable across a range of tokenization lengths. Across all modalities, the tokenizers used in our work have low reconstruction losses. We will add figures to the Appendix of our paper illustrating this. For ECG and respiratory signals, reconstruction errors are nearly imperceptible. As discussed in the paper, continuous alternatives such as diffusion modelling will also likely work well, but we adopt discrete next-token prediction to inherit well-established training recipes and leave this for future work.

“A recent sleep foundation model [1] is missed in the manuscript”

Thank you for bringing SleepMaMi to our attention. This was published just after our initial submission. We will add this to our discussion in the paper.

Authors · CommentOpenReview ↗

Dear reviewer,

Thanks again for your feedback, and for your patience as we performed new experiments to address your concerns and strengthen the findings of our work.

Below we provide follow-ups to your key original feedback:

“The central claim that NTP is superior to MAE/CL for stochastic signals is not supported by isolated evidence”

MAE:

We have performed new isolated scaling experiments comparing NTP with MAE using unimodal EEG models, to isolate the effect of the learning objective on noisy physiological signals. These results, using matched compute across Transformer configurations, show that NTP outperforms MAE across model scales:

Table B: Input-space MAE vs. Hypnos across model scale. Sleep staging κ (MLP probe) on held-out MrOS using single-channel EEG (C3). Both models use matched Transformer widths, context length, and pre-training compute, with the learning rate tuned per configuration.

Model size Width MAE Hypnos EEG
tiny 192 0.649 0.766
small 384 0.657 0.783
base 768 0.725 0.795

Contrastive learning:

We re-implemented the state-of-the-art contrastive approach, sleep2vec, and have performed model-scaling experiments using matched Transformer backbones. Across model scales, Hypnos provides significantly stronger performance. For example, hypnos-Tiny outperforms sleep2vec-large across downstream tasks on the held-out test set.

Model Transformer Backbone Enc (M) Staging κ Apnoea AUC Arousal AUC Desat AUC
sleep2vec-tiny 12L/192d 19.0 0.679 0.723 0.829 0.700
hypnos-tiny 12L/192d 19.7 0.771 0.780 0.912 0.736
sleep2vec-small 12L/384d 49.3 0.732 0.748 0.859 0.710
hypnos-small 12L/384d 53.6 0.793 0.786 0.918 0.756
sleep2vec-medium 12L/768d 144.1 0.757 0.765 0.873 0.733
hypnos-base 12L/768d 163.8 0.815 0.808 0.934 0.767
sleep2vec-large 16L/1024d 282.8 0.766 0.777 0.883 0.750

Controlled scaling law experiments across the three axes: (model, data and compute) would further strengthen arguments about the superiority of a specific learning objective, but this is beyond the scope of this work. This is an important future direction that we will discuss in the final paper.

“Can you isolate the objective (NTP vs. masked token prediction) with tokenizer/backbone fixed?”

As detailed in our central response, we have provided additional results that show BERT-like masked token prediction with a tuned masking ratio (50% from a grid search of 25/50/75) provides similar downstream probing performance to NTP. The additional advantage of next-token prediction is that it simultaneously unifies representation modelling and AR generative modelling (i.e. forecasting) into a single architecture without train-test shift, and enables streaming inference for physiological state tracking. These additional experiments have improved the clarity of our results by highlighting the broader value of discrete token modelling for physiological signals, and we will refine the paper to make this point clearer.

CRP necessity

We have shown that the alternative approach of random dropout also enables missing-modality robustness, and we will make it clear that CRP, a minor component of our work, is just one way to achieve this. A valuable negative result is that different train-time masking strategies lead to equivalent downstream performance on restricted modality configurations, despite inducing very different training-time distributions, e.g. a 20x difference in single-channel data exposure.

We hope this addresses your concerns, and would be very grateful if you would consider raising your score in light of these strengthened findings.

Reviewer y6X9 · CommentOpenReview ↗

Quick response

Dear authors, thanks for the response.

Before posting a more comprehensive response, I'd like to first note that detailed discussion on SleepMaMi, qualitatively and quantitatively, are still missed. I've checked that both SleepMaMi and OSF were published in ICML 2026 and SleepMaMi was open on arxiv before OSF (February 2026).

Given that there are just a couple of sleep foundation models currently, and OSF is more about an experimental study rather than suggesting a new methodology, I see sharp discussion on SleepMaMi (including performance comparison) an important piece of the rebuttal to validate the contributions of this paper.

For example, some claims would be impacted by including SleepMaMi since it trains a Mamba-based macro encoder on > 500 minutes, and it trains not only a shared encoder but also a private encoder for each modality to preserve its own characteristics.

Comments on the paper

5 comments
Authors · CommentOpenReview ↗

Central Response (Part 1)

We thank all reviewers for taking the time to provide thoughtful and thorough reviews of our work. Here we wish to address common points raised by all reviewers, which we will refer back to in individual responses.

NTP vs alternatives

Reviewers have suggested running a controlled ablation of NTP vs masked token prediction (MTP). Masked-token prediction (e.g. BERT) is closely related to NTP, and also overcomes the issues with MAE and contrastive learning methods highlighted in the paper. In our argument from Line 73 onwards, we motivate NTP over masked input-space reconstruction methods, i.e. MAE. Prior ML work such as I-JEPA has long made the case that MAE expends model capacity on unpredictable low-level detail. We argue that this issue is particularly severe in the physiological signal domain, and that NTP is one route to overcome it. However, this is by no means the only way. On Line 82 we note that latent diffusion is one promising alternative approach. We have run new experiments comparing NTP with (BERT-like) MTP with a 50% masking ratio (grid search over 25/50/75%). Summary results (linear probe, SHHS) are given below:

Model Staging κ Staging AUROC Arousal AUROC Arousal AUPRC Apnea AUROC Apnea AUPRC Desat AUROC Desat AUPRC
MTP 0.813 0.971 0.926 0.754 0.869 0.785 0.829 0.590
NTP 0.817 0.974 0.920 0.737 0.864 0.777 0.837 0.612

We have found that these approaches perform very similarly on downstream evaluations. We will add these results to the final paper, and make clearer that our critique of MAE is reconstruction in input space. We will also amend the title of the final paper to e.g. 'Hypnos: Learning Generalisable Representations of Sleep Physiology via Next-Token Prediction', removing the word 'Enables' as we did not intend to imply that only NTP scales. The advantages of NTP over MTP are that it conveniently unifies representation learning and generative modelling into a single architecture with no train-test shift, and permits sequential state updates for e.g. real-time sleep staging and event detection.

Modality masking

We have performed new experiments to isolate the effect of cross-modal attention and modality masking during training and inference. We have compared four training scenarios using Hypnos-Small:

a) No cross-modal attention (i.e. CRP alpha -> infinity) during training or inference.

b) No masking (i.e. CRP alpha -> 0) during training.

c) Random channel dropout with p=0.5. An alternative to CRP.

d) Default i.e. CRP masking with alpha = 1.

These experiments reveal three findings:

  • Cross-modal learning matters. α → ∞ reduces performance across both full and restricted configurations, even e.g. using single-channel (M=1) data.
  • Training-time masking improves missing-modality robustness without reducing full modality performance.
  • The specific training-time masking strategy is unimportant.

We expected that CRP would improve restricted-modality performance over random masking, since it exposes the model to single-channel sequences in roughly 2 of 3 examples versus 1 in 32 under independent dropout at p = 0.5. Despite this 20× difference in exposure, the two strategies were indistinguishable across downstream restricted modality evaluations. This was a surprising result, because it indicates that training-time sampling does not need to be tailored to a specific downstream sensor configuration. We will temper specific claims around CRP. For example, on Line 55 we will remove mention of 'novel masking strategy' to avoid giving the impression that CRP specifically enables better robustness. CRP gave us a single convenient parameter to interpolate between no cross-modal attention (α → ∞) and no modality masking (α → 0) during training.

Table A: Modality-masking ablation. Per-subject mean of the primary metric per task on SHHS using linear probing. Restr. is the mean across three restricted-modality configurations (EEG-C3, EOG, ECG+ABD+THX); Full uses all eight modalities.

Variant Staging (κ) Full Staging (κ) Restr. Arousal (AUROC) Full Arousal (AUROC) Restr. Apnoea (AUROC) Full Apnoea (AUROC) Restr. Desat. (AUROC) Full Desat. (AUROC) Restr.
No training-time masking
Independent (α → ∞) 0.773 0.656 0.866 0.838 0.847 0.798 0.817 0.776
No masking (α → 0) 0.792 0.659 0.900 0.864 0.861 0.802 0.830 0.769
Training-time modality masking
Random (p = 0.5) 0.795 0.672 0.902 0.873 0.860 0.813 0.831 0.796
Default (α = 1) 0.797 0.676 0.901 0.874 0.859 0.814 0.831 0.798
Authors · CommentOpenReview ↗

Central Response (Part 2)

Hypnos vs. baselines

As noted by the AC, reviewers have requested additional experiments to demonstrate that Hypnos ‘scales better’ than alternative approaches. We have run new experiments comparing Hypnos with OSF (DINO) and sleep2vec (CL) using matched Transformer backbones, identical dataset splits and pre-processing steps. Results from these experiments (MLP, held-out MrOS) are given below, sorted by encoder parameter count. We report backbone configs, and the final encoder parameter count, excluding e.g. contrastive projection heads for sleep2vec, student params for OSF, and discrete output codebooks for Hypnos.

Note: The table below is out-of-date, please see our latest comment titled 'Hypnos vs. Alternatives'

Model Transformer Backbone Enc (M) Staging κ Apnoea AUC Arousal AUC Desat AUC
OSF-tiny 12L/192d 5.4 0.651 0.716 0.851 0.664
sleep2vec-tiny 12L/192d 19.0 0.679 0.723 0.829 0.700
hypnos-tiny 12L/192d 19.7 0.771 0.780 0.912 0.736
OSF-small 12L/384d 21.4 0.717 0.758 0.888 0.711
sleep2vec-small 12L/384d 49.3 0.732 0.748 0.859 0.710
hypnos-small 12L/384d 53.6 0.793 0.786 0.918 0.756
OSF-base 12L/768d 85.3 0.728 0.780 0.905 0.735
sleep2vec-medium 12L/768d 144.1 0.757 0.765 0.873 0.733
hypnos-base 12L/768d 163.8 0.815 0.808 0.934 0.767
sleep2vec-large 16L/1024d 282.8 0.766 0.777 0.883 0.750

A notable result here is that Hypnos-Tiny (20 M) often outperforms the largest variants of OSF and sleep2vec. We believe this provides strong additional evidence that our SOTA results are driven by a better learned representation (same feature dimensionality), and not simply by a larger model.

Reviewers have also suggested compute-matched experiments, noting that Hypnos uses more compute than the baselines. We have launched experiments scaling the compute of both OSF and sleep2vec, scaling the number of training steps and/or the batch size by 4x with the LR tuned. Initial results indicate that neither approach shows significant improvement over Hypnos with additional compute at fixed model/data size. We will report final results as soon as training/evaluation completes in the next 24-48h. Update: Please see our latest comment titled 'Hypnos vs. Alternatives' for updated results. Controlled scaling law experiments across the three axes: (model, data and compute) would further strengthen arguments about the superiority of a specific learning objective, but this is beyond the scope of this work. This is an important future direction that we will discuss in the final paper.

Generative capability

Beyond achieving state-of-the-art performance, another advantage of Hypnos over existing models is that it unifies generative modelling and representation learning into a single architecture. As pointed out by V7oh, this advantage was not exploited in our original submission. For any subset of supported modalities, Hypnos can be used to auto-regressively generate synthetic signals, optionally conditioned on existing signal context. Qualitatively, we find that these generations preserve waveform morphology and cross-modal structure, indicating that next-token prediction captures the joint distribution of the underlying signals. We will update the paper with generative examples that demonstrate the ability of Hypnos to capture stochastic structure, e.g. replacing Figure 1 with a real example that shows a generative ECG distribution during an arrhythmia vs. regular rhythm.

Reviewer wCoc · CommentOpenReview ↗

Thank the authors for the additional experiments. I have a follow-up question for "our critique of MAE is reconstruction in input space". Where do you show NTP/MTP is better than MAE in reconstruction space?

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…