potentialpaper

STREAM: Stochastic Riemannian Flow Matching with Anisotropic Decoder for Digital Histopathology Image Generation

Won June Cho, Daeky Jeong, Hyeongyeol Lim, Hongjun Yoon

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. STREAM runs Riemannian flow matching in a pathology VFM's hyperspherical latent: a bridge perturbation guarantees per-token rectifiability, and a decoder with Jacobian-shaped anisotropic noise adds superadditive gains for SOTA gFID on 3 datasets.

Abstract. Synthetic histopathology image generation addresses patient-privacy concerns and the growing data demands of foundation models. Existing state-of-the-art histopathology generative models use pretrained Vision Foundation Models (VFMs) as conditioning signals. We show this yields conditioning-dominated diversity: on TCGA-BRCA, 62–75% of their output diversity is attributable to the conditioning signal rather than the learned latent space, while de novo synthesis still requires a VFM embedding at inference. We instead use histopathology VFMs as the latent space itself: their patch tokens are ℓ2\ell_2-normalized on the unit hypersphere Sd−1\mathcal{S}^{d-1} with strong angular dominance and intrinsic curvature, motivating a Riemannian formulation. We present STREAM, the first framework to apply Riemannian flow matching in the histopathology domain, in two stages: 1) a bridge-type stochastic perturbation that establishes per-token rectifiability on Sd−1\mathcal{S}^{d-1} for training a Diffusion Transformer, and 2) a novel decoder training design whose noise covariance is anisotropic in the left-singular basis of the per-token tangent-projected velocity-field Jacobian, spending a large robustness budget on its low-response directions and a small one on its high-response directions. Across TCGA-BRCA, TCGA-COADREAD and SPIDER-skin, STREAM achieves state-of-the-art gFID and ranks first on nearly all histopathology-specific metrics as well. Code and a public gallery of generated images are available at https://chokevin8.github.io/STREAM-Patho/.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
4 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (spotlight)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (spotlight) · 4 reviews · OpenReview

Updated 25 Nov 2026, 03:48 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (spotlight)
Read decision
Meta-review

Final Meta Review

1. Summary of the Contribution

The paper proposes STREAM, the first framework to apply Riemannian Flow Matching to histopathology image generation. The contribution is built around two coupled mechanisms:

  1. a stochastic bridge-like perturbation that establishes a token-wise rectifiability property on the hypersphere Sd−1\mathcal{S}^{d-1} for training a latent-space DiT (Theorem 3);
  2. an anisotropic decoder whose noise covariance matrix is shaped by the singular value decomposition of the Jacobian of the velocity field of the trained DiT—low noise along high-energy directions (preserving fidelity) and high noise along low-energy directions (absorbing the generator’s residual drift).

The authors report a superadditive effect from combining the two mechanisms, achieving state-of-the-art performance on TCGA-BRCA and competitive performance on TCGA-COADREAD.

2. Overall Assessment After the Discussion

The discussion period convincingly addressed several concerns raised during the initial review, particularly regarding the generality of the method beyond a single encoder. This development warrants an upward revision of the assessment of several aspects of the work, as detailed in Section 3.

3. Strengths Confirmed by the Discussion Period

The single decisive weakness identified in the initial meta-review — absence of downstream utility validation — has been comprehensively resolved. The authors provide three independent, pixel-level downstream evaluations: (1) nuclear morphometry (HoVer-NeXt, ~2.5M nuclei) showing ≤2% deviation from real tissue on seven shape descriptors; (2) self-supervised pre-training (DINO ViT-S/16, 1M tiles/organ) where a STREAM-only encoder matches a real-data encoder on nine out-of-distribution binary tasks (SPIDER, MHIST); (3) spatial transcriptomics prediction (HEST, 50 HVGs) where STREAM embeddings achieve Pearson correlations on par with real data. This directly substantiates the paper’s stated motivation of supplying training data for foundation models.

Generalization to a second pathology encoder (resolved). The authors explicitly acknowledge that validation with a single encoder (UNI) was insufficient and provide two compelling additions: (i) a complete replication with Virchow2, showing that the gain provided by the bridge + anisotropic decoder combination over an isotropic control is maintained, and even slightly amplified, with the second encoder; and (ii) a controlled-encoder comparison (UNI for all methods, including retrained RAE, SVG, and REPA-E), extended to a third, non-TCGA dataset (SPIDER-skin, from a different organ), where STREAM consistently outperforms the alternatives. The limitations affecting absolute comparability across encoders (patch dimension, retina size, and tile resizing) are candidly acknowledged by the authors themselves, which strengthens rather than weakens the credibility of the demonstration. This issue, which could by itself have justified a rejection, is now considered adequately addressed.

Methodological strengthening through additional ablations. The two additional ablations—the four-way comparison of the parameterization/loss pairing (chord vs. geodesic, endpoint vs. velocity prediction) and the comparison of noise-schedule shapes (one- or two-mode Karhunen–Loève truncation versus stochastic interpolants and variance exploding profiles)—provide empirical justification for design choices that were not supported in the initial version. The authors correctly point out that no published Riemannian flow-matching method at this dimensional scale had performed this comprehensive comparison; this constitutes a genuine methodological contribution, even though it remains secondary to the main contribution.

4. Theoretical Scope Clarified (Post-Rebuttal)

The authors clarified the precise scope of Theorem 3: parts (i)–(iii) (full support, rectifiability, smooth marginal velocity) lift from a single sphere to the product manifold (S^{d-1})^N without any cross-token assumption. The cross-token regularity assumption is confined to Proposition 7's transport-rate bound (O(ϑ²_max)), not to rectifiability itself. The authors measured the actual cross-token coupling in the trained DiT at 0.21% of diagonal-block Frobenius energy (averaged over 50 centroids × 500 probes × 9 timesteps), providing a first-order empirical proxy for the quantity the assumption controls. This distinction is now explicitly stated in the manuscript (Section 4.2) and will be further emphasized in the camera-ready revision. While a full theoretical guarantee for the product manifold remains open—as acknowledged in the limitations—the gap is now clearly delimited and empirically bounded.

5. Experimental Rigor Completed (Post-Rebuttal)

  • Statistical significance: Multi-seed evaluation is now reported (5 seeds @10K, 3 seeds @50K for main results; 5 seeds for all four ablation cells). Margins are large multiples of seed spread (e.g., STREAM 6.53±0.03 vs. RAE 15.88±0.04 vs. SVG 17.52±0.14 on TCGA-BRCA @50K).
  • Computational cost: Full characterization provided — NFE vs. gFID curves at matched budgets (STREAM leads at every NFE; at NFE=26 beats baselines at NFE=50), per-image cost (12.14 TFLOPs, 94.8 ms on H200), and GPU-hours breakdown (JVP+SVD stage = 69 GPU-h, 12.6% of total pipeline; decoder training dominates at 299 GPU-h). Storage requirements also reported (~30 GB spectral cache, 5.9 TB pre-extracted features avoidable via on-the-fly extraction).

All technical gaps raised in the initial review have been addressed with new experiments or theoretical clarifications.

6. Remaining Limitations (Non-Blocking, to be Addressed in Camera-Ready)

  • Virchow2 validated on one dataset (BRCA) at reduced budget with a backbone-size confound; second dataset run committed for camera-ready.
  • Full product-manifold theoretical guarantee remains open; empirical proxy (0.21% cross-token coupling) provided and scope explicitly delimited in Section 4.2 / camera-ready.
  • No blinded pathologist study; public gallery of generated images planned for release.
  • Dependence on strong domain-matched VFM is a precondition shared by all baselines (PixCell, ZoomLDM, RAE, PathDiff).

7. Verdict

STREAM delivers a robust and original methodological advance for unconditional histopathology image generation:

  • Geometric diagnosis (hyperspherical concentration, intrinsic curvature) → justified Riemannian formulation.
  • Stochastic bridge (Theorem 3) resolves the disconnected-support obstruction of deterministic SLERP — first stochastic RFM at this scale.
  • Spectral-informed anisotropic decoder breaks the reconstruction/generation trade-off (demonstrated super-additivity).
  • Comprehensive evaluation: distributional metrics (pathology-aware), reconstruction, three downstream pixel-level validations, multi-encoder generality (UNI, Virchow2, Phikon-v2), controlled ablations, complexity, and statistical significance.

The critical shortcoming identified in the initial review (lack of downstream validation) has been resolved by conclusive, independent experiments.

Recommendation: Accept (conditional on camera-ready integrating the 10 committed items detailed in the SAC comment).


Area Chair

Final justification

The work constitutes a genuine methodological advance — geometrically principled stochastic Riemannian flow matching with a spectral anisotropic decoder that breaks the reconstruction/generation trade-off — now backed by distributional, reconstruction, and downstream utility evidence across multiple pathology encoders and datasets.

Area Chair zHQe · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

Final Meta Review

1. Summary of the Contribution

The paper proposes STREAM, the first framework to apply Riemannian Flow Matching to histopathology image generation. The contribution is built around two coupled mechanisms:

  1. a stochastic bridge-like perturbation that establishes a token-wise rectifiability property on the hypersphere Sd−1\mathcal{S}^{d-1} for training a latent-space DiT (Theorem 3);
  2. an anisotropic decoder whose noise covariance matrix is shaped by the singular value decomposition of the Jacobian of the velocity field of the trained DiT—low noise along high-energy directions (preserving fidelity) and high noise along low-energy directions (absorbing the generator’s residual drift).

The authors report a superadditive effect from combining the two mechanisms, achieving state-of-the-art performance on TCGA-BRCA and competitive performance on TCGA-COADREAD.

2. Overall Assessment After the Discussion

The discussion period convincingly addressed several concerns raised during the initial review, particularly regarding the generality of the method beyond a single encoder. This development warrants an upward revision of the assessment of several aspects of the work, as detailed in Section 3.

3. Strengths Confirmed by the Discussion Period

The single decisive weakness identified in the initial meta-review — absence of downstream utility validation — has been comprehensively resolved. The authors provide three independent, pixel-level downstream evaluations: (1) nuclear morphometry (HoVer-NeXt, ~2.5M nuclei) showing ≤2% deviation from real tissue on seven shape descriptors; (2) self-supervised pre-training (DINO ViT-S/16, 1M tiles/organ) where a STREAM-only encoder matches a real-data encoder on nine out-of-distribution binary tasks (SPIDER, MHIST); (3) spatial transcriptomics prediction (HEST, 50 HVGs) where STREAM embeddings achieve Pearson correlations on par with real data. This directly substantiates the paper’s stated motivation of supplying training data for foundation models.

Generalization to a second pathology encoder (resolved). The authors explicitly acknowledge that validation with a single encoder (UNI) was insufficient and provide two compelling additions: (i) a complete replication with Virchow2, showing that the gain provided by the bridge + anisotropic decoder combination over an isotropic control is maintained, and even slightly amplified, with the second encoder; and (ii) a controlled-encoder comparison (UNI for all methods, including retrained RAE, SVG, and REPA-E), extended to a third, non-TCGA dataset (SPIDER-skin, from a different organ), where STREAM consistently outperforms the alternatives. The limitations affecting absolute comparability across encoders (patch dimension, retina size, and tile resizing) are candidly acknowledged by the authors themselves, which strengthens rather than weakens the credibility of the demonstration. This issue, which could by itself have justified a rejection, is now considered adequately addressed.

Methodological strengthening through additional ablations. The two additional ablations—the four-way comparison of the parameterization/loss pairing (chord vs. geodesic, endpoint vs. velocity prediction) and the comparison of noise-schedule shapes (one- or two-mode Karhunen–Loève truncation versus stochastic interpolants and variance exploding profiles)—provide empirical justification for design choices that were not supported in the initial version. The authors correctly point out that no published Riemannian flow-matching method at this dimensional scale had performed this comprehensive comparison; this constitutes a genuine methodological contribution, even though it remains secondary to the main contribution.

4. Theoretical Scope Clarified (Post-Rebuttal)

The authors clarified the precise scope of Theorem 3: parts (i)–(iii) (full support, rectifiability, smooth marginal velocity) lift from a single sphere to the product manifold (S^{d-1})^N without any cross-token assumption. The cross-token regularity assumption is confined to Proposition 7's transport-rate bound (O(ϑ²_max)), not to rectifiability itself. The authors measured the actual cross-token coupling in the trained DiT at 0.21% of diagonal-block Frobenius energy (averaged over 50 centroids × 500 probes × 9 timesteps), providing a first-order empirical proxy for the quantity the assumption controls. This distinction is now explicitly stated in the manuscript (Section 4.2) and will be further emphasized in the camera-ready revision. While a full theoretical guarantee for the product manifold remains open—as acknowledged in the limitations—the gap is now clearly delimited and empirically bounded.

5. Experimental Rigor Completed (Post-Rebuttal)

  • Statistical significance: Multi-seed evaluation is now reported (5 seeds @10K, 3 seeds @50K for main results; 5 seeds for all four ablation cells). Margins are large multiples of seed spread (e.g., STREAM 6.53±0.03 vs. RAE 15.88±0.04 vs. SVG 17.52±0.14 on TCGA-BRCA @50K).
  • Computational cost: Full characterization provided — NFE vs. gFID curves at matched budgets (STREAM leads at every NFE; at NFE=26 beats baselines at NFE=50), per-image cost (12.14 TFLOPs, 94.8 ms on H200), and GPU-hours breakdown (JVP+SVD stage = 69 GPU-h, 12.6% of total pipeline; decoder training dominates at 299 GPU-h). Storage requirements also reported (~30 GB spectral cache, 5.9 TB pre-extracted features avoidable via on-the-fly extraction).

All technical gaps raised in the initial review have been addressed with new experiments or theoretical clarifications.

6. Remaining Limitations (Non-Blocking, to be Addressed in Camera-Ready)

  • Virchow2 validated on one dataset (BRCA) at reduced budget with a backbone-size confound; second dataset run committed for camera-ready.
  • Full product-manifold theoretical guarantee remains open; empirical proxy (0.21% cross-token coupling) provided and scope explicitly delimited in Section 4.2 / camera-ready.
  • No blinded pathologist study; public gallery of generated images planned for release.
  • Dependence on strong domain-matched VFM is a precondition shared by all baselines (PixCell, ZoomLDM, RAE, PathDiff).

7. Verdict

STREAM delivers a robust and original methodological advance for unconditional histopathology image generation:

  • Geometric diagnosis (hyperspherical concentration, intrinsic curvature) → justified Riemannian formulation.
  • Stochastic bridge (Theorem 3) resolves the disconnected-support obstruction of deterministic SLERP — first stochastic RFM at this scale.
  • Spectral-informed anisotropic decoder breaks the reconstruction/generation trade-off (demonstrated super-additivity).
  • Comprehensive evaluation: distributional metrics (pathology-aware), reconstruction, three downstream pixel-level validations, multi-encoder generality (UNI, Virchow2, Phikon-v2), controlled ablations, complexity, and statistical significance.

The critical shortcoming identified in the initial review (lack of downstream validation) has been resolved by conclusive, independent experiments.

Recommendation: Accept (conditional on camera-ready integrating the 10 committed items detailed in the SAC comment).


Area Chair

Final justification

The work constitutes a genuine methodological advance — geometrically principled stochastic Riemannian flow matching with a spectral anisotropic decoder that breaks the reconstruction/generation trade-off — now backed by distributional, reconstruction, and downstream utility evidence across multiple pathology encoders and datasets.

1 comment
Authors · CommentOpenReview ↗

Response to Area Chair zHQe

Dear Area Chair,

We sincerely thank you for the meta-review, which set the agenda for our discussion period. All five additions you asked for were addressed and posted. We summarize each below for your convenience.

(1) Downstream evaluation and practical utility. We report three, all on generated pixels rather than on latent statistics. A) Nuclear morphometry: HoVer-NeXt, a published segmentation-and-classification model, run over 50,000 real and 50,000 generated TCGA-COADREAD patches, roughly 2.5M nuclei per run, puts STREAM within 2.0% of real on all seven per-nucleus shape descriptors. B) Self-supervised pretraining: DINO ViT-S/16 trained from scratch on 1M STREAM-generated tiles per organ (BRCA and COADREAD) against 1M real, then frozen and linear-probed on held-out SPIDER and MHIST, where the synthetic-trained encoder is essentially on par with the real-trained one across nine binary tasks. C) Spatial transcriptomics (gene expression prediction): the HEST probe, predicting the 50 most variable genes from frozen embeddings on both BRCA and COADREAD, where STREAM again matches real at this inherently biologically harder downstream task.

(2) Encoder ablation with a second pathology VFM. We retrained the full pipeline on Virchow2. At a matched 45K decoder budget on TCGA-BRCA the anisotropic decoder reaches 6.37 rFID / 10.48 gFID against 11.28 / 14.75 for the isotropic control, just like the gain we saw on UNI. In relative terms the two gains match closely, 44% and 29% against UNI's 46% and 27%. What this isolates is STREAM's decoder contribution: within each encoder the bridge is held in place and the only change is the decoder's noise geometry, so the anisotropic construction is what buys 2.99 rFID and 2.51 gFID on UNI and 4.91 and 4.27 on Virchow2. So, it moves reconstruction and generation together rather than trading one against the other unlike RAE's isotropic design. We have also since added a third histopathology VFM, Phikon-v2, at rFID 7.31 / gFID 10.05 (we will include its isotropic control in the revision), so STREAM seems to be relatively robust to most histopathology VFMs.

(3) Significance testing. We report five sampling seeds at 10,000 samples and three at the full 50,000. Re-measured end to end at 50,000, the three TCGA-BRCA cells are STREAM 6.53 ± 0.03, RAE 15.88 ± 0.04 and SVG 17.52 ± 0.14, so the margins between the means are significant. The ablation grid is seeded on the same basis: the four cells of the bridge-and-decoder ablation each carry five sampling seeds, so the ordering within that grid is also resolved well beyond seed noise.

(4) Complexity metrics. We report gFID against NFE at 6, 10, 26 and 50 for STREAM, RAE and SVG at matched budgets. At deployed NFE = 50, STREAM achieves 6.53 ± 0.03, while baselines RAE and SVG achieve 15.88 ± 0.04 and 17.52 ± 0.14. STREAM leads at every NFE and at NFE = 26 already beats both baselines at NFE 50. Per generated image at NFE = 50, STREAM costs 12.14 TFLOPs and 94.8 ms against RAE's 16.09 and 156.7 and SVG's 24.16 and 175.0. The comparison is controlled: RAE and SVG take the same UNI encoder and the same TCGA-BRCA training set at their own published defaults. The significance is that STREAM is not buying quality with the VFM/encoder or compute — it is ahead on gFID at every NFE and simultaneously cheaper per image in both FLOPs and wall-clock, so the margin is attributable to the method rather than to a larger sampling budget.

(5) Theoretical clarification on singular vectors and Jacobian temporal dependence. On singular vectors, the construction uses the left factor, which App. E of main text pins by construction, and we settled it empirically by retraining a decoder on the right-factor basis, which costs 1.15 rFID and 1.25 gFID. We theoretically clarified that the left and right factors select the same 236-dimensional budget and differ only in which subspace they select, so the question was decidable by experiment, and the retrain decides it. On the Jacobian's time dependence, we theoretically clarified that the basis is extracted at a single anchor, t=0.99t{=}0.99, which the submission did not state and the revision will. We measured the sensitivity rather than assuming it away: adjacent-anchor alignment is 0.297 against 0.529 across centroids, so the anchor matters more than the cross-centroid spread the cache absorbs. We therefore now present the static single-anchor cache as an approximation and a stated limitation rather than as a potential invariance claim.

We believe we have addressed all of the concerns raised in your meta-review and throughout the discussion period. We respectfully hope that our responses, together with the additional experiments/results, theoretical clarifications, and camera-ready revisions outlined throughout the discussion, will be taken into account in the final evaluation of our paper.

Reviewer g7J9OpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes STREAM, a stochastic Riemannian flow-matching framework for unconditional histopathology image generation. The method directly models normalized pathology foundation-model tokens on a product of hyperspheres, rather than using them only as conditioning signals. It combines a stochastic spherical bridge, which perturbs intermediate geodesic states while preserving the endpoints, with an anisotropic decoder whose noise directions are determined by the local spectral structure of the learned velocity field.

The framework is evaluated on TCGA-BRCA and TCGA-COADREAD against several recent pathology generation methods. The results indicate strong generation quality and suggest that the stochastic bridge and anisotropic decoder are most effective when used together. The use of pathology-aware metrics further strengthens the empirical evaluation.

The main concerns are theoretical and methodological. The relationship between the stochastic bridge and the training velocity is not fully derived, the practical role of the full-support result is unclear under a uniform source distribution, and the use of singular vectors in the decoder may be inconsistent with the input-space perturbation mechanism. In addition, the time dependence of the Jacobian basis, the low-energy drift assumption, the dependence on the chosen encoder, and the lack of fully controlled baselines require further clarification.

Strengths and weaknesses

Strengths

The paper is well motivated and addresses a relevant problem in unconditional histopathology image generation. Modeling normalized pathology foundation-model tokens on a product of hyperspheres is geometrically appropriate, and the stochastic spherical bridge offers an interesting extension of deterministic Riemannian flow matching by perturbing intermediate states while preserving the endpoints. The spectral-informed anisotropic decoder is also conceptually appealing because it explicitly links the local sensitivity of the generator to the robustness of the decoder. The ablation results suggest that the stochastic bridge and anisotropic decoder are complementary, and the use of pathology-specific evaluation metrics makes the experimental assessment more meaningful.

Weaknesses

Several theoretical and methodological issues remain insufficiently resolved. The definition of “conditioning collapse” is not fully justified, and the per-token theory does not directly extend to the cross-token dependencies introduced by the Transformer architecture. The connection between the stochastic bridge and the endpoint-prediction objective is not rigorously derived, while the practical significance of the full-support result is unclear when the source distribution is already uniform on the sphere. The use of left rather than right singular vectors in the decoder may be mathematically inconsistent, and the time dependence of the velocity-field Jacobian is not adequately handled. In addition, the assumption that generation errors concentrate in low-energy directions is not directly verified, the gains appear sensitive to the choice of encoder, the controlled baselines are incomplete, and the computational overhead is not reported in sufficient detail.

Questions

Q1. Can the authors derive the exact conditional velocity associated with the stochastic spherical bridge and explain why the endpoint-prediction velocity used during inference is consistent with this path? If the relationship is only approximate, an error analysis would be helpful.

Q2. Why is the full-support property considered important when the source distribution is already uniform over the sphere? Please provide a concrete example showing that deterministic SLERP can still produce problematic intermediate support under the coupling used in the paper.

Q3. Does the anisotropic decoder use the left or right singular vectors of the velocity-field Jacobian? Since decoder noise is injected in the latent input space, the right singular vectors would appear to be the relevant directions. Please clarify the notation and implementation.

Q4. How is the time dependence of the Jacobian handled when constructing the cached spectral basis? At which timestep, or over which set of timesteps, is the Jacobian evaluated, and how stable are the dominant subspaces across the generation trajectory?

Q5. Can the authors directly verify that latent generation errors are concentrated in the low-energy spectral subspace? Reporting the projected error energy in the high- and low-energy subspaces would provide direct evidence for the proposed decoder design.

Q6. Can the authors add controlled comparisons using the same UNI encoder for Euclidean flow matching, deterministic spherical flow matching, stochastic spherical flow matching, isotropic decoder regularization, and anisotropic decoder regularization? These experiments are needed to separate the effects of the encoder, geometry, bridge, and decoder.

Q7. How do the per-token theoretical results extend to the full Transformer model with cross-token self-attention? Please specify which claims apply only to the probability path and which require additional smoothness or independence assumptions.

Q8. How is “conditioning collapse” distinguished from desirable dependence on the conditioning signal? Additional analyses of latent utilization, condition permutation, and output diversity under a fixed condition would make this claim more convincing.

Q9. How sensitive is the method to the choice of pathology encoder? Since the anisotropic decoder appears less effective with DINOv2-L, please discuss the conditions under which the proposed spectral mechanism is expected to work.

Q10. What is the total computational overhead of STREAM, including DiT training, Jacobian-vector products, randomized SVD, clustering, spectral-basis caching, and decoder training? Reporting GPU hours, preprocessing time, and storage requirements would improve reproducibility.

Limitations

Weaknesses

Several theoretical and methodological issues remain insufficiently resolved. The definition of “conditioning collapse” is not fully justified, and the per-token theory does not directly extend to the cross-token dependencies introduced by the Transformer architecture. The connection between the stochastic bridge and the endpoint-prediction objective is not rigorously derived, while the practical significance of the full-support result is unclear when the source distribution is already uniform on the sphere. The use of left rather than right singular vectors in the decoder may be mathematically inconsistent, and the time dependence of the velocity-field Jacobian is not adequately handled. In addition, the assumption that generation errors concentrate in low-energy directions is not directly verified, the gains appear sensitive to the choice of encoder, the controlled baselines are incomplete, and the computational overhead is not reported in sufficient detail.

Final justification

After considering the authors’ detailed rebuttal and follow-up, I have increased my score. The authors have satisfactorily addressed all major concerns by clarifying the bridge as a training-time smoothing mechanism, correcting the left-singular-vector interpretation, removing the unsupported low-energy error-concentration claim, acknowledging the temporal-anchor and Euclidean-comparison limitations, moderating the conditioning terminology, narrowing the encoder-dependent claims, and adding the requested computational details and condition-permutation analysis. These revisions substantially improve the technical accuracy, transparency, and scope of the paper; the remaining issues are primarily presentational rather than fundamental. Given the methodological originality and strong empirical results.

Formatting concerns

NA

11 comments
Authors · CommentOpenReview ↗

Response to Reviewer g7J9 (Part 9/9)

Q9. Encoder sensitivity.

The condition is spectral, with two distinct parts. (i) Cross-centroid stability of the Jacobian's dominant singular subspace, measured by principal angles [C] between the top-k=64k{=}64 subspaces of every pair of K=50K{=}50 centroids. Aggregation order matters: App. F.1 of main text reports median alignment 0.3600.360 for UNI against 0.2280.228 for DINOv2-L, both measured identically, so the ordering holds. That number pools each centroid's 256 token bases before orthonormalizing and takes a median; the matched per-(centroid, token) statistic used in Q4 gives UNI a mean of 0.529\mathbf{0.529}. (ii) A non-degenerate effective rank: DINOv2-L's k∗k^\ast distribution contains a degenerate (centroid, token) cell that UNI never produces. Only (ii) concerns the singular values, and we will separate the two in the revision.

However, we believe that domain matching is the most reliable route to both, not a separate requirement. The burden falls on the decoder rather than the generator: a DiT trained on domain-mismatched DINOv2-L still produces distributionally correct latents, at a latent Fréchet-distance ratio of 1.04 (App. F.3 of main text). Each FD is taken in its own encoder's latent space so the ratio compares each DiT against its own target. The end-to-end gFID gap (Table 6 of main text) therefore isolates to the decoder.

On a second pathology encoder: we first re-ran the pipeline with Virchow2 features on the same LightningDiT-XL backbone, to hold the architecture, configuration and hyperparameters fixed while only the encoder changed. That configuration turned out to be architecturally defective, as Virchow2 emits 1280-dimensional patch tokens while the deployed LightningDiT-XL has hidden size 1152. UNI at 1024 sits below the hidden size, so the deployed configuration is unaffected, and this is a property of the generator we chose rather than of VFM quality.

RAE report a similar bottleneck empirically: their Table 3 supports Theorem 1, which establishes a non-zero loss lower bound for diffusion models of the form Bf(Axt,t)Bf(Ax_t,t) when the hidden dimension satisfies d<nd{<}n. We cannot yet verify that this transfers to STREAM, but it points at the same bottleneck. We are therefore retraining at LightningDiT-1.0B (hidden size 1536 > 1280), which does not have this issue, and will report the Virchow2 numbers as soon as the run completes, within the discussion period. That change does make the model substantially larger, 1.03B parameters against 676M. Whatever the result, it will carry a backbone-size confound alongside the encoder change, and we will report it with that stated.

Q10. Computational overhead.

We report the computational overhead measured from our training logs and file sizes, for the deployed STREAM configurations (TCGA-BRCA, 12.2M tiles at 256×256, UNI (d=1024d{=}1024, N=256N{=}256 tokens)) on one node of 8×H200 NVIDIA GPUs:

stage wall-clock GPU-hours
Encoder feature extraction 5.2 h 42
DiT training, 95K steps 16.9 h 135
kk-means (K=50K{=}50), JVP, randomized SVD, basis caching 8.6 h 69
Decoder training, 90K steps 37.4 h 299
Total ~68.1 h ~545

The spectral stage uses m=600m{=}600 tangent probes per (centroid, token) through the frozen DiT, giving k∗=236k^\ast{=}236 at τ=0.90\tau{=}0.90. Within that 8.6 h, kk-means takes minutes while Jacobian probing plus the per-token SVDs take the rest. That cost is an implementation constraint rather than an intrinsic one: torch.func.jvp needs forward-mode AD, which neither FlashAttention nor the memory-efficient SDPA kernel supports, so attention falls back to the MATH path with the full N×NN\times N matrix materialized per head per block, and torch.compile must be disabled because compiled blocks are opaque to vmap. A finite-difference JVP, or forward-mode support in a fused kernel, would reduce it substantially; we kept the exact JVP because it is what the method specifies.

Storage is ~6.1 TB, but the pre-extracted UNI features for TCGA-BRCA's 12.2M 256×256 images are 5.9 TB, which is actually entirely avoidable by sacrificing a few additional hours on DiT and decoder training via extracting features on-the-fly during training. The other storage requirements like the spectral-basis cache at 30 GB and the centroid cache at megabyte levels are negligible.

The STREAM method-specific overhead is therefore the JVP and SVD stage alone: 69 GPU-h, 12.6% of the pipeline, and 30 GB of storage. Everything else is what any latent generative model with a learned diffusion model and pixel decoder pays. The decoder dominates and the anisotropic noise adds negligible training cost. We will add these figures to the revision if needed.

References

[C] Björck Å., Golub G.H. Numerical Methods for Computing Angles Between Linear Subspaces. Math. Comp. 27(123):579–594, 1973.

Authors · CommentOpenReview ↗

Response to Reviewer g7J9 (Part 8/9)

Q8. Conditioning collapse vs. desirable conditioning dependence.

The two are separated by where the diversity comes from, which is what the decomposition H(X)=H(X∣C)+I(X;C)H(X)=H(X\mid C)+I(X;C) measures through ρcond=I(X;C)/H(X)\rho_{\text{cond}}=I(X;C)/H(X). Desirable dependence means the model uses CC and still produces varied outputs once CC is held fixed, so H(X∣C)H(X\mid C) stays large and ρcond\rho_{\text{cond}} small. Collapse means nearly all the diversity is attributable to CC varying, so H(X∣C)H(X\mid C) falls away and ρcond\rho_{\text{cond}} approaches 1. Table 1 of main text measures the latter on TCGA-BRCA in UNI space: ρcond\rho_{\text{cond}} is 76% for ZoomLDM and 62% for PixCell, with H(X∣C)H(X\mid C) of 1.28 and 1.81 against totals of 5.17 and 4.78.

What separates them directly is what happens when CC is removed. PixCell cannot sample without being handed a VFM embedding, and ZoomLDM only sidesteps that by learning a second generative model over the embedding, so in both cases the variation left once CC is fixed is what 1−ρcond1-\rho_{\text{cond}} quantifies at 24% and 38%. Forced to sample from its own latent space, PixCell reaches 104.18 gFID on TCGA-BRCA against 6.616.61 for STREAM in Table 3 of main text: the latent space alone does not support generation, which is the collapse side of the criterion shown directly.

A cross-model diversity check agrees. STREAM's H(X)H(X) is 5.26\mathbf{5.26} from noise alone, above either baseline's total of 5.175.17 and 4.784.78, so it generates more variety with no conditioning signal than they achieve with their condition free to vary. STREAM is unconditional, so ρcond\rho_{\text{cond}}, I(X;C)I(X;C) and H(X∣C)H(X\mid C) do not apply to it, whereas H(X)H(X) needs only samples.

Of the three analyses requested, two reduce to that pair and one does not. Output diversity at fixed condition is H(X∣C)H(X\mid C), Table 1 of main text. Latent utilization is 1−ρcond=H(X∣C)/H(X)1-\rho_{\text{cond}}=H(X\mid C)/H(X), the 24% and 38% above. Condition permutation is genuinely different, as we interpret it as seeing if dependence on CC is semantically correct or merely high mutual information carried by a spurious feature, which the entropy decomposition cannot determine. We will report it in the revision if possible. Note that all values are Shannon entropies of the UNI kernel spectrum, whose exponential is the Vendi Score [B], under the marginal-entropy estimator of App. C.2, Step 3, of main text, which needs only samples.

References

[B] Friedman D., Dieng A.B. The Vendi Score. TMLR 2023; Jalali M. et al. Conditional Vendi Score. AISTATS 2026.

Authors · CommentOpenReview ↗

Response to Reviewer g7J9 (Part 7/9)

Q7. Per-token theory vs. cross-token attention.

All three parts of Thm. 3 lift from a single Sd−1\mathcal S^{d-1} to the product (Sd−1)N(\mathcal S^{d-1})^N with no additional cross-token assumption. The probability path is built per token, and nothing is assumed about how the N=256N{=}256 tokens covary: Prop. 2's only hypothesis is on the coupling of a single token pair, which Q2 weakens further. What is independent is the bridge noise, and that is exact by construction rather than assumed. For (i)–(ii), the SLERP geodesic, the exponential map and the tangent Gaussian all act per token, so the conditional density of XtX_t given (x0,x1)(x_0,x_1) factorizes and is positive and smooth exactly when each factor is. Part (iii) follows from the bridge kernel itself: its proof uses only the dominating function from (ii), Prop. 6's velocity bound and σ(t)≥σmax⁡sin⁡(πϵt)>0\sigma(t)\ge\sigma_{\max}\sin(\pi\epsilon_t)>0, all of which lift, with NN entering the constants, not the hypotheses. §4.1 and §4.2 of main text both enumerate (i)–(ii) and are silent on (iii); we will state all three in the revision.

Cross-token C2C^2 regularity enters only in Prop. 7's O(σmax⁡2)O(\sigma_{\max}^2) transport bound, and there it applies to the deterministic velocity vtdetv_t^{\text{det}}, not to the bridge-smoothed vtv_t of (iii), which the smoothing itself makes regular. The assumption therefore bounds only the transport rate, not rectifiability or smoothness. To bound that coupling we probe the DiT's tangent-restricted Jacobian with single-token tangent probes (50 kk-means centroids × 500 probes × 9 interior tt, a sweep separate from App. E of main text's m=600m{=}600 cache) and split each response into the probed token's own block and the blocks of the other N−1N{-}1 tokens.

With RR the mean off-diagonal-block Frobenius energy divided by the mean diagonal-block energy, carrying a 1/(N−1)1/(N{-}1) normalization inside, we measure 0.21% averaged over interior tt and ≤0.61%\le0.61\% at every probed tt. We report RR per block because the coupling of interest is between a token pair; the sum over all N−1N-1 blocks is inflated by the block count and is not what Prop. 7's hypothesis concerns. A no-bridge model at matched hyperparameters carries coupling of the same order (0.30% mean, ≤0.54%\le0.54\% at every probed tt), so this is a property of the trained transformer, not of our construction.

Reviewer H8PAOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes STEAM, a Riemannian flow matching framework designed for the unconditional generation of histopathology images directly within the latent space of vision foundation models. They argued that existing diffusion models experience conditioning collapse and lack semantic structure due to VAE latents. They use VFM features to solve the issue, which encode rich and class-discriminative information within the angular structure of a hypersphere (Sd−1S^{d-1}). To handle the high curvature and disconnected structure of VFM manifolds, STREAM uses a stochastic bridge Riemannian Flow Matching framework with a Brownian bridge perturbation. To bypass the usual reconstruction-generation tradeoff when decoding high-dimensional features, the authors design a spectral-informed anisotropic decoder. This component optimizes noise robustness using SVD of the diffusion Transformer's velocity-field Jacobian. The method is evaluated on TCGA-BRCA and TCGA-COADREAD, showing state-of-the-art generation (gFID) and reconstruction (rFID) metrics compared to existing pathology and natural-image baselines.

Strengths and weaknesses

Quality: (1) strengths: The empirical evaluation is good across distribution-matching metrics. The ablation study shows the super-additive effects of pairing the stochastic bridge with the anisotropic decoder. Using velocity field Jacobian is logical. (2) weakness: The theory contains gaps. Theorem 3 analyses a single Sd−1S^{d-1} hypersphere, whereas the actual model operates on a product manifold (Sd−1)256(S^{d-1})^{256}. The authors admit that bounding the transport requires an unverified C2C^2 cross-token regularity assumption. The main results lack statistical significance testing, which weakens the reliability of the performance margins.

Clarity: (1) strength: The motivation for moving from Euclidean to Riemannian flow matching is clearly articulated and backed by empirical evidence. (2) weakness: The exact meaning of image quality is not clear from a clinical standpoint. While the mathematical framing is good, the biological relevance of the generated images is not clearly verified. The authors rely solely on automated metrics and a visual inspection of a few selected image patches.

Significance: (1) strength: Generative modelling directly within VFM latent spaces bypasses the need for traditional VAEs. By solving the inherent reconstruction-generation tradeoff in this domain, this work provides a contribution that could meaningfully influence future medical generative architectures. (2) weakness: The clinical utility of the method remains unproven. A generated histopathology patch that satisfies an Inception network (or a vision foundation model like Virchow2) does not guarantee true biological fidelity, nor does it ensure usefulness for downstream clinical tasks, such as training diagnostic classifiers.

Originality: (1) strength: The combination of stochastic bridge perturbations with an SVD-guided anisotropic decoder is a novel approach to stabilizing diffusion/flow-matching in highly sensitive manifold spaces.

Questions

(1) How strictly does the independence assumption in Theorem 3 limit the practical guarantees on the product manifold (Sd−1)256(S^{d-1})^{256}? Could you provide empirical estimates or at least a bounding approximation of the C2C^2 cross-token velocity regularity. This would bridge the gap between your per-token theory and product-manifold deployment (2) FID, KID, and LPIPS measure distribution matching and perceptual similarity, but they do not guarantee biological consistency. Have you tested the utility of STREAM-generated images in downstream tasks (e.g., training a classifier for benign vs. malignant on synthetic data and testing on real data)? (3) It seems that STREAM's anisotropic decoder advantage is largely erased when using an out-of-domain encoder (DINOv2-L). Does this imply STREAM is reliant on the domain-specific properties of the UNI encoder? If a user wishes to apply STREAM to a different medical modality (e.g., radiology) where a perfect VFM does not exist, will the method fail? (4) Establishing statistical significance is critical given the varying margins between STREAM and the baselines. Could you please provide variance/error bars for the FID metrics across multiple random seeds for at least a subset of models, please?

Limitations

While the authors have acknowledged the theoretical limitations of their work, they have not adequately addressed the limitations regarding clinical applicability. Generating visually realistic 256X256 tissue patches does not guarantee that the cellular structure maintain true physiological relationships or that they are free of biological hallucinations. It would need further validation.

Final justification

The rebuttal strengthens the empirical case, but much of the new evidence was added late and could not be independently assessed. Key limitations remain. the product-manifold transport result is only empirically supported, the method depends on a strong domain-matched VFM, and biological fidelity lacks blinded pathologist validation. These issues lead me to a more cautious assessment.

Formatting concerns

No major formatting or anonymity violations are observed.

8 comments
Authors · CommentOpenReview ↗

Response to Reviewer H8PA (Part 3/3)

Q3. Reliance on UNI, and modalities without a strong VFM (continued).

We'd like to clarify that a strong domain-matched VFM is a precondition of the paradigm rather than of our explicit construction.

First, PixCell and ZoomLDM, the prior state of the art in histopathology generation, condition their latent diffusion models on histopathology-VFM embeddings, with PixCell requiring one at inference and ZoomLDM synthesising them with a second generative model. The other baselines we select (RAE and SVG) also train in a VFM feature space as we do. Therefore, all of these models can be reasonably assumed to be sensitive to the quality of the VFM encoder's embeddings, and STREAM also follows the same logic.

If no encoder of this quality exists in a different domain, we accept the mechanism would degrade, but the burden would move on to the decoder, not the generator. This is because as long as the DiT trains well, DiT still produces distributionally correct latents. We already show this as when STREAM is trained in a domain mismatched (an extreme example) natural domain DINOv2-L VFM, the bridge DiT still generates accurate features (latent Fréchet-distance ratio 1.04 over 1,000 generated latents, App. F.3 of main text).

Furthermore, the bridge and the anisotropic decoder can and should apply to any pipeline that treats ℓ2\ell_2-normalised encoder features as a generative latent space and models them on a Riemannian manifold. What is specific to histopathology is the problem we chose, a domain where expert annotation cannot scale to every patch and unconditional generation is therefore the setting that matters. We leave applying STREAM's techniques to other modalities to future work.

Q4. Error bars and significance.

We report standard deviations over 5 independent sampling seeds, each generating 10K samples, for STREAM, RAE and SVG on TCGA-BRCA and TCGA-COADREAD and for all four cells of the Table 4 of main text ablation. Since FID depends on sample count these runs estimate the spread only: the means are unchanged at 50K, with the seed SD reported beside them. We only report gFID as rFID reconstructs a fixed set of real images and is seed-independent.

gFID, mean ± SD over 5 seeds TCGA-BRCA TCGA-COADREAD
STREAM 6.61 ± 0.18 7.68 ± 0.15
RAE 15.84 ± 0.18 19.64 ± 0.23
SVG 17.37 ± 0.29 23.64 ± 0.13

The four Table 4 of main text ablation cells get the same treatment:

Ablation cell (TCGA-BRCA) gFID, mean ± SD
No bridge, isotropic 9.07 ± 0.24
No bridge, anisotropic 8.27 ± 0.21
Bridge, isotropic 9.37 ± 0.15
Bridge, anisotropic (ours) 6.86 ± 0.18

From here, we can also confirm that our superadditive interaction of bridge and anisotropic decoder is indeed robust: the deployed cell sits far clear of all three alternatives. Furthermore, for STREAM and its baselines RAE and SVG, we re-measured gFID end-to-end at the full 50K sample count on TCGA-BRCA trained with the UNI encoder. We report a total of three sampling seeds:

gFID at 50K, mean ± SD over 3 seeds TCGA-BRCA
STREAM 6.53 ± 0.03
RAE 15.88 ± 0.04
SVG 17.52 ± 0.14

All three reproduce their published means to within the seed spread above. Note that the RAE and SVG numbers here differ from the main text's because they are retrained on UNI (d=1024d{=}1024) rather than on their own natural-image encoders (DINOv2/v3), so that all three models share one encoder and the comparison with STREAM is fair.

Authors · CommentOpenReview ↗

Response to Reviewer H8PA (Part 2/3)

Q2. Downstream utility (continued).

(2) Self-supervised pretraining. We believe this is STREAM's best downstream use. Its samples carry no labels, and we have no labeller we would trust to attach one for evaluation, which is precisely why (1) measures the generated pixels directly, through a robust pretrained segmentation model, instead of through a pseudo-labelled classifier.

We therefore trained DINO ViT-S/16 [D] models from scratch for 75 epochs under identical hyperparameters, on 1M STREAM-generated tiles per organ (BRCA and COADREAD) and, separately, on 1M real tiles: synthetic 1M STREAM against real 1M TCGA. A random-init ViT-S/16 serves as the control, and every trained encoder is frozen and probed identically so that only embedding quality is compared. We report linear-probe AUROC on SPIDER [E], with no slide contamination between train and test splits (binary classes drawn from SPIDER-Breast and SPIDER-Colorectal), plus MHIST [F] for COADREAD. Both probe sets are out-of-distribution (no TCGA overlap), while both encoders, real or STREAM-generated, see only TCGA tiles during DINO training.

AUROC Rand. STREAM Real
SPIDER COADREAD Adenoma vs Adenoca. 0.890 0.952 0.958
SPIDER COADREAD Adenoca. HG vs LG 0.883 0.964 0.959
SPIDER COADREAD Adenoma HG vs LG 0.668 0.951 0.943
SPIDER COADREAD HP vs SSL 0.926 0.977 0.979
MHIST COADREAD HP vs SSA 0.612 0.879 0.867
SPIDER BRCA DCIS HG vs LG 0.976 0.998 0.998
SPIDER BRCA NST vs Lobular 0.766 0.953 0.966
SPIDER BRCA In-situ vs Invasive 0.935 0.994 0.994
SPIDER BRCA Benign vs Malignant 0.737 0.979 0.983

Rand. is averaged over 3 independent network draws (5 for MHIST).

An encoder pretrained only on STREAM-generated images is essentially on par with one pretrained on real images, which is exactly the deployment case for STREAM: synthetic data for pretraining foundation models. Since classification is a fairly saturated task in histopathology, we also run an inherently harder downstream task on the same pretrained encoders.

COADREAD / BRCA Rand. STREAM Real
HEST, ridge (avg PCC) 0.144 / 0.163 0.284 / 0.313 0.280 / 0.333
HEST, XGBoost (avg PCC) 0.128 / 0.145 0.247 / 0.307 0.269 / 0.283

HEST [G] pairs H&E tiles with matched spatial transcriptomics; the task is to predict, from a tile's frozen embedding alone, how strongly each of the top-50 highly-variable genes (HVGs) is expressed in that tile. We fit a ridge regression and a gradient-boosted regressor (XGBoost) on the embeddings and report the average Pearson correlation coefficient (PCC), per gene and averaged over the 50 genes and the folds, again on the official uncontaminated split.

This is the stricter probe, since morphology predicts expression only insofar as the embedding has captured real tissue biology rather than texture. STREAM again performs on par with real, which is the more telling evidence that its images carry genuine biological fidelity.

Q3. Reliance on UNI, and modalities without a strong VFM.

The condition the mechanism needs is actually rather spectral, and it has two distinct parts. (i) Cross-centroid stability of the Jacobian's dominant singular subspace, measured by principal angles between the top-k=64k{=}64 subspaces of every pair of K=50K{=}50 centroids, the canonical subspace-similarity tool [H]: UNI gives median alignment 0.3600.360 against DINOv2-L's 0.2280.228 (App. F.1 of maint ext). (ii) A non-degenerate effective rank: DINOv2-L's k∗k^\ast distribution contains degenerate centroids (k∗=1k^\ast{=}1) that UNI never produces. We should separate these two explicitly in the paper, since only (ii) concerns the singular values.

Both quantities are read off the cached Jacobian SVD, so when applying this to a new modality, we could possibly use this as an approximate guidance metric to predict downstream performance. Therefore, domain matching is not a second, independent requirement but is just the most reliable route to satisfying this one.

References

[D] Caron M., Touvron H., Misra I., Jégou H., Mairal J., Bojanowski P., Joulin A. Emerging Properties in Self-Supervised Vision Transformers. ICCV 2021.

[E] Nechaev D., Pchelnikov A., Ivanova E. SPIDER: A Comprehensive Multi-Organ Supervised Pathology Dataset and Baseline Models. arXiv:2503.02876, 2025.

[F] Wei J. et al. A Petri Dish for Histopathology Image Analysis. AIME 2021, LNCS 12721:11–24.

[G] Jaume G. et al. HEST-1k: A Dataset for Spatial Transcriptomics and Histology Image Analysis. NeurIPS 2024.

[H] Björck Å., Golub G.H. Numerical Methods for Computing Angles Between Linear Subspaces. Math. Comp. 27(123):579–594, 1973.

Authors · CommentOpenReview ↗

Response to Reviewer H8PA (Part 1/3)

We sincerely thank the reviewer's insightful review and efforts in analyzing our manuscript. We respond to each of the reviewer's questions one-by-one below:

Q1. How much does the per-token assumption cost on the product manifold?

All three parts of Thm. 3 lift from one Sd−1\mathcal S^{d-1} to the product (Sd−1)N(\mathcal S^{d-1})^N with no additional assumption, and none on the data: p1p_1 on the product is an arbitrary joint law over the 256 tokens, the independence being in the noise, which is exact by construction. For (i)–(ii), the SLERP geodesic, exponential map and tangent Gaussian all act per token, so the joint density factorizes and is positive and smooth exactly when each factor is. Part (iii) follows from the bridge kernel itself: its proof uses only the dominating function from (ii), the velocity bound of Prop. 6 and σ(t)≥σmax⁡sin⁡(πϵt)>0\sigma(t)\ge\sigma_{\max}\sin(\pi\epsilon_t)>0, all of which lift, with NN entering the constants but not the hypotheses. §4.1 of main text enumerates (i)–(ii) and is silent on (iii); we will state all three.

The cross-token C2C^2 assumption is required only for Prop. 7's O(σmax⁡2)O(\sigma_{\max}^2) transport bound, and there it applies to the deterministic velocity vtdetv_t^{\text{det}}, not to the bridge-smoothed vtv_t of part (iii), which the smoothing itself makes regular. So the assumption does not underwrite rectifiability; it bounds only the transport rate, which is what a bounding approximation should target.

To bound that coupling empirically, we probe the STREAM DiT's tangent-restricted Jacobian with single-token tangent probes (50 kk-means centroids × 500 probes × 9 interior tt) and split each response into the probed token's own block and the blocks of the other N−1N{-}1 tokens (N=256N{=}256). We define the per-block ratio RR as the mean off-diagonal-block Frobenius energy divided by the mean diagonal-block energy, with a 1/(N−1)1/(N{-}1) normalization inside. The resulting ratio is 0.21% averaged over interior tt and ≤0.61%\le0.61\% at every probed tt. Therefore, average cross-token coupling is weak, providing a first-order empirical proxy for the cross-token interactions that the assumption is intended to control. A no-bridge model at matched hyperparameters is factorized to the same order (0.30% mean, ≤0.54%\le0.54\% at every probed tt), so this is a property of the trained transformer rather than of our construction. We will add this to the paper if needed.

Q2. Downstream utility.

We agree that distribution metrics, including the Virchow2-based FvD, KvD and vMMD, which are pathology-aware without being biologically validating, cannot on their own establish diagnostic utility. We report two downstream evaluations, both of which assess the generated pixels directly.

(1) Nuclear morphometry. We ran HoVer-NeXt [A], a pretrained and published nuclei segmentation-and-classification model, over 50,000 real and 50,000 STREAM-generated TCGA-COADREAD patches (~2.5M nuclei per arm). The real set is halved, so real A against real B shows what agreement looks like. Shape descriptors follow scikit-image regionprops conventions [B], perimeter by the Crofton estimator; circularity follows [C]. Nuclei per tile is HoVer-NeXt's instance count.

Mean values:

Mean, TCGA-COADREAD real A real B STREAM
nuclei per tile 51.87 51.49 55.36
area (px²) 195.4 197.1 195.2
perimeter (px) 49.61 49.78 49.91
circularity 0.840 0.840 0.846
eccentricity 0.741 0.742 0.737
solidity 0.935 0.935 0.937
major axis (px) 19.11 19.18 19.13
minor axis (px) 11.14 11.17 11.36

STREAM's mean sits within 2.0% of real on all seven per-nucleus shape descriptors, and within 6.7% on nuclei per tile. Nuclear size and shape are what a pathologist reads, so agreement at this level can be taken as evidence that STREAM's samples carry biologically relevant structure.

References

[A] Baumann E., Dislich B., Rumberger J.L., Nagtegaal I.D., Rodriguez Martinez M., Zlobec I. HoVer-NeXt: A Fast Nuclei Segmentation and Classification Pipeline for Next Generation Histopathology. MIDL 2024, PMLR 250:61–86.

[B] van der Walt S. et al. scikit-image: image processing in Python. PeerJ 2:e453, 2014.

[C] Janssen A.F.J., Breusegem S.Y., Larrieu D. Current Methods and Pipelines for Image-Based Quantitation of Nuclear Shape and Nuclear Envelope Abnormalities. Cells 11(3):347, 2022.

Reviewer Ts11OpenReview ↗
Rating
4/6
Confidence
4/5
Quality
2/4
Clarity
3/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper introduces STREAM, a generative modeling framework that applies Riemannian Flow Matching (RFM) to the L2L^2-normalized latent space of a pretrained Vision Foundation Model (VFM). To address the disconnected-support issues of deterministic spherical flows, the authors propose a stochastic bridge interpolation. Furthermore, the decoder is regularized via an anisotropic noise injection strategy scaled by the singular value decomposition (SVD) of the generator's velocity-field Jacobian.

Strengths and weaknesses

Strengths:

  1. Replacing the deterministic SLERP conditional path with a stochastic bridge (Theorem 3) is a mathematically sound resolution to the disconnected-support obstruction in standard Riemannian flow matching.
  2. Coupling the decoder's robustness budget to the specific velocity-field sensitivities of the DiT via SVD is a structurally rigorous approach to managing the reconstruction-generation trade-off.

Weaknesses:

  1. For a flow matching paper, the absence of computational complexity metrics is unacceptable. The authors state a 25-step midpoint Euler solver is used, but provide zero analysis on Number of Function Evaluations (NFE) vs. generation quality. There is no proof that their velocity field yields straighter paths or faster sampling than standard diffusion baselines.
  2. The model is evaluated purely on perceptual and distributional metrics (FID, LPIPS). Generating visually convincing tissue patches is insufficient for computational pathology if the synthetic data cannot be proven to retain diagnostic fidelity (e.g., via training downstream classifiers or segmentation models).
  3. The authors claim a "novel anisotropic decoder." The architecture is a standard ViT-XL; the novelty resides entirely in the noise covariance injected during the training phase. Furthermore, the core methodology is domain-agnostic; its pathology specificity relies entirely on plugging in external models (UNI embeddings and a Kaiko discriminator).
  4. The pipeline relies on a highly specialized Kaiko ViT-S/8 discriminator. The authors fail to ablate this module against a standard, domain-agnostic PatchGAN. It is unclear if the improved reconstruction fidelity stems from the anisotropic noise or simply the use of a powerful, domain-matched adversarial prior.
Questions
  1. What are the exact wall-clock inference times and total FLOPS for the generation pipeline? Please provide an NFE vs. performance (FID) trade-off curve comparing STREAM to the baselines.
  2. How does the framework perform on a quantitative downstream clinical task? (e.g., replacing real data with STREAM-generated data to train a basic tissue classifier).
  3. How does the pipeline perform if the domain-specific Kaiko discriminator is replaced with a standard PatchGAN?
  4. Why categorize the decoder as architecturally "novel" when only the noise injection protocol differs from standard ViT decoders?
Limitations

No. The authors do not discuss the practical computational limitations, NFE latency costs, and the lack of downstream diagnostic validation for their generated images.

Final justification

Looking at the other reviews, discussions, and new results, my concerns are mostly resolved. What helped me raise my score was specifically the addition of downstream validation (nuclear morphometry, SSL pretraining, HEST probe), which was lacking in the original submission. The Virchow2 numbers also confirmed that the anisotropic decoder's benefit is not just a UNI artifact. Although I am increasing my rating, it is noteworthy to state that the Virchow2 result is limited to one dataset (BRCA) at a reduced budget (with an acknowledged backbone-size confound). That said, generalization is supported but not fully settled. Furthermore, I am scoring under the assumption that the agreed-upon corrections (dropping the low-energy claim, softening "conditioning collapse," clarifying scoping) will actually appear in the camera-ready PDF.

A final note for the authors:

  • Please ensure the terminology and scoping changes discussed here actually make it into the final revision.
  • A second dataset for the Virchow2 result would go a long way toward closing the generalizability question.
  • Ultimately, your core idea (the stochastic bridge, the SVD-coupled anisotropic decoder) is solid and remains the true contribution of the paper; the extra discussion evaluations strengthen the case, but the method itself is the main reason for acceptance.
Formatting concerns

None

6 comments
Authors · CommentOpenReview ↗

Response to Reviewer Ts11 (Part 3/3)

Q4. Why the decoder is called novel.

We agree the architecture is a standard ViT-XL; the paper says "novel decoder design", never novel architecture, and we will make that unambiguous. The novelty claimed is the construction of the noise covariance, tied to the bridge-based Riemannian formulation rather than a protocol that transfers anywhere. Decoder noise augmentation in RAE-style pipelines is isotropic, and its published behaviour is an explicit trade-off: RAE adds n∼N(0,σ2I)n\sim\mathcal N(0,\sigma^2 I) to the decoder's latent input and reports that it improves gFID but slightly worsens rFID. Shaping the covariance by the Jacobian's SVD breaks that trade-off rather than moving along it — Table 4 of main text improves rFID and gFID together.

The direct evidence is that transplanting both components into a Euclidean pipeline does not reproduce the effect. Below is Table 4 of main text reproduced for RAE's DiT and decoder, identical setup, UNI as the VFM, TCGA-BRCA (rFID/gFID):

Euclidean RAE Isotropic decoder Anisotropic decoder
No bridge 6.00 / 24.39 5.80 / 25.38
Bridge 6.00 / 23.89 5.82 / 24.06

Blindly applying the same bridge and anisotropic decoder in a Euclidean latent space does not work. (Plain LightningDiT-XL backbone, no DDT head, so latent dimensions match STREAM; internally comparable, not comparable to the main text's RAE results.)

The decoder-level probe agrees. Extending Table 5 of main text to n=2000n{=}2000, the directional-Lipschitz ratio Rdec=LUH/LULR_\text{dec}=L_{U_H}/L_{U_L} at k=64k{=}64:

RdecR_\text{dec}, TCGA-BRCA Isotropic Anisotropic Change
STREAM, bridge 0.42 3.41 8.1×
STREAM, no bridge 0.62 2.50 4.1×
Euclidean RAE 0.98 0.99 1.01×

Anisotropic training inverts the decoder's directional preference on the sphere and does nothing in the Euclidean pipeline.

On the method being domain-agnostic.

We agree the bridge and the anisotropic decoder are domain-agnostic: they should apply to any pipeline that treats ℓ2\ell_2-normalised representation-encoder features as the generative latent space and models them on a Riemannian manifold. We do not claim the techniques are pathology-specific.

What is pathology-specific is the problem. Histopathology is close to an intrinsically unconditional setting: expert annotation cannot scale to every patch, whole-slide synthesis is computationally out of reach so patch-level generation is the natural unit, and the domain's state of the art — ZoomLDM, PixCell, PathDiff [H] — is uniformly conditional, built on VAE latents we show are semantically weak (Table 2 of main text) and conditioning-collapsed (Table 1 of main text). PixCell reports no unconditional results and offers no way to sample without a VFM embedding; PathDiff's inference conditioning set is restricted to {text-only, mask-only, both}. STREAM addresses that gap, and Q2's evaluations are where it is shown to be worth closing: an unconditional generator is what a label-free pretraining corpus requires. Applying the techniques to other domains is future work.

References

[H] Bhosale S. et al. PathDiff: Histopathology Image Synthesis with Unpaired Text and Mask Conditions. ICCV 2025.

Authors · CommentOpenReview ↗

Response to Reviewer Ts11 (Part 2/3)

Q2. Downstream diagnostic fidelity (continued).

(2) Self-supervised pretraining. We believe this is the best downstream use for STREAM. Its generated samples carry no labels and there is no labeller we would trust to attach one to evaluate it — which is why (1) above measures the generated pixels directly via a robust pretrained segmentation model rather than evaluating through a pseudo-labelled classifier.

To do this, we trained DINO ViT-S/16 [D] models from scratch for 75 epochs with identical hyperparameters on 1M STREAM-generated tiles per organ (BRCA and COADREAD) and, separately, on 1M real tiles (DINO trained with synthetic 1M STREAM tiles against real 1M TCGA tiles). A random-init ViT-S/16 is included as a control, and every trained DINO/encoder is frozen and probed identically for evaluation of its embedding quality. We report linear-probe AUROC on SPIDER [E] with no slide contamination between train and test splits (binary classes generated from SPIDER-Breast and SPIDER-Colorectal) plus MHIST [F] for COADREAD. Both datasets are out-of-distribution (no overlap with TCGA), while both encoders, real or STREAM generated, see only TCGA tiles during DINO training.

AUROC Rand. STREAM Real
SPIDER COADREAD Adenoma vs Adenoca. 0.890 0.952 0.958
SPIDER COADREAD Adenoca. HG vs LG 0.883 0.964 0.959
SPIDER COADREAD Adenoma HG vs LG 0.668 0.951 0.943
SPIDER COADREAD HP vs SSL 0.926 0.977 0.979
MHIST COADREAD HP vs SSA 0.612 0.879 0.867
SPIDER BRCA DCIS HG vs LG 0.976 0.998 0.998
SPIDER BRCA NST vs Lobular 0.766 0.953 0.966
SPIDER BRCA In-situ vs Invasive 0.935 0.994 0.994
SPIDER BRCA Benign vs Malignant 0.737 0.979 0.983

Rand. is averaged over 3 independent network draws (5 for MHIST).

We can clearly tell that the DINO/encoder pretrained only on STREAM generated images is essentially on par with one pretrained on real images, which realizes the deployment case for STREAM: synthetic data for pretraining foundation models. Furthermore, because classification is a rather saturated task in histopathology, we perform an inherently harder downstream task on the same pretrained encoders.

COADREAD / BRCA Rand. STREAM Real
HEST, ridge (avg PCC) 0.144 / 0.163 0.284 / 0.313 0.280 / 0.333
HEST, XGBoost (avg PCC) 0.128 / 0.145 0.247 / 0.307 0.269 / 0.283

HEST [G] pairs H&E tiles with matched spatial transcriptomics. Its task is to predict, from a tile's frozen embedding alone, how strongly each of the top-50 highly-variable genes (HVGs) is expressed in that tile (gene expression prediction task). We fit a ridge regression and a gradient-boosted regressor (XGBoost) on the embeddings and report the average Pearson correlation coefficient (PCC), per gene and averaged over the 50 genes and the folds. We use the official uncontaminated train-test split here as well.

This is the stricter probe as morphology predicts expression only insofar as the embedding has captured real tissue biology rather than texture. STREAM performs on par to real, which is a more telling evidence that STREAM generated images do have high biological fidelity.

Q3. Replacing the Kaiko discriminator.

With everything else identical, we ablate the discriminator used for decoder training at 45K decoder steps. We substituted DINO ViT-S/8 rather than PatchGAN: it is the discriminator RAE uses — the pipeline STREAM's decoder is built on — so it is the field-standard control for this architecture and a stronger baseline than PatchGAN, from the same natural-image domain.

Discriminator (TCGA-BRCA, 45K decoder steps) rFID ↓ gFID ↓
Kaiko ViT-S/8 (deployed) 3.52 6.86
DINO ViT-S/8 (RAE's) 4.33 7.21

So the domain-matched discriminator is worth 0.81 rFID / 0.35 gFID — a real design choice, and a small fraction of STREAM's margin over the Euclidean baselines: the advantage does not stem from the adversarial prior. (Both at 45K decoder steps, matched to Table 4 of main text.)

We ran the same ablation on RAE, identical UNI embeddings, trained and evaluated on TCGA-BRCA: giving RAE the Kaiko discriminator in place of its own DINO ViT-S/8 moves its gFID from 15.84 to 16.81. The domain-matched discriminator is not a transferable advantage.

References

[D] Caron M. et al. Emerging Properties in Self-Supervised Vision Transformers. ICCV 2021.

[E] Nechaev D., Pchelnikov A., Ivanova E. SPIDER: A Comprehensive Multi-Organ Supervised Pathology Dataset and Baseline Models. arXiv:2503.02876, 2025.

[F] Wei J. et al. A Petri Dish for Histopathology Image Analysis. AIME 2021.

[G] Jaume G. et al. HEST-1k: A Dataset for Spatial Transcriptomics and Histology Image Analysis. NeurIPS 2024.

Authors · CommentOpenReview ↗

Response to Reviewer Ts11 (Part 1/3)

We sincerely thank the reviewer's insightful review and efforts in analyzing our manuscript. We respond to each of the reviewer's questions one-by-one below:

Q1. Inference cost and the NFE–FID trade-off.

We apologize for the omission of NFE: the paper gives the step count only. The midpoint sampler evaluates the DiT twice per step, so our 25 steps are 50 NFE. RAE and SVG also run at 50 NFE, so Table 3 of main text was at a matched budget. Note that better generation quality may correlate with straighter paths, but we make no straightness claims for STREAM.

Then we report the requested gFID against NFE on TCGA-BRCA with the UNI encoder, 50,000 samples per point, 3 seeds, mean ± SD for STREAM and baselines RAE and SVG:

NFE STREAM RAE SVG
6 49.70 ± 0.09 55.03 ± 0.05 55.80 ± 0.07
10 27.05 ± 0.06 29.87 ± 0.06 30.53 ± 0.18
26 9.31 ± 0.02 18.27 ± 0.04 18.82 ± 0.15
50 6.53 ± 0.03 15.88 ± 0.04 17.52 ± 0.14

6 and 26 replace 5 and 25 because the midpoint sampler spends two DiT calls per step; all models run at the same NFE. STREAM leads at every NFE, and at NFE = 26 already beats both baselines at NFE = 50. The margin also widens with compute: the gap is 5.33 (RAE) / 6.10 (SVG) at NFE = 6 against 9.35 / 10.99 at NFE = 50. Note that the baseline numbers at NFE = 50 are different compared to the main text's numbers (also reported at NFE = 50) because RAE and SVG were trained with UNI instead of natural domain DINOv2/v3 for a more fair comparison with STREAM.

We also report inference cost at the deployed NFE = 50, both quantities per generated image:

At NFE = 50 TFLOPs ms
STREAM 12.14 94.8
RAE 16.09 156.7
SVG 24.16 175.0

FLOPs are counted over the complete sampling call, which is every network evaluation plus the decoder. Throughput/latency is wall-clock at a generation batch of 32, divided by the batch, measured on a single NVIDIA H200 GPU.

Q2. Downstream diagnostic fidelity.

We agree that distribution metrics — including the Virchow2-based FvD, KvD and vMMD, pathology-aware but not biologically validating — cannot establish diagnostic utility by themselves. We report two downstream evaluations that assess the generated pixels directly.

(1) Nuclear morphometry. We ran HoVer-NeXt [A], a published/pretrained nuclei segmentation-and-classification model, on 50,000 real and 50,000 STREAM-generated TCGA-COADREAD patches (~2.5M nuclei per arm). The real set is split in two, so real A vs real B shows what agreement looks like. Shape descriptors follow scikit-image regionprops conventions [B], with perimeter by the Crofton estimator; circularity follows [C]. Nuclei per tile is HoVer-NeXt's instance count.

Mean values:

Mean, TCGA-COADREAD real A real B STREAM
nuclei per tile 51.87 51.49 55.36
area (px²) 195.4 197.1 195.2
perimeter (px) 49.61 49.78 49.91
circularity 0.840 0.840 0.846
eccentricity 0.741 0.742 0.737
solidity 0.935 0.935 0.937
major axis (px) 19.11 19.18 19.13
minor axis (px) 11.14 11.17 11.36

Across all seven per-nucleus shape descriptors, STREAM's mean sits within 2.0% of real, and nuclei per tile within 6.7%. Nuclear size and shape are what a pathologist reads, so agreement at this level can be evidence that STREAM's samples carry biologically relevant structure.

References

[A] Baumann E. et al. HoVer-NeXt: A Fast Nuclei Segmentation and Classification Pipeline for Next Generation Histopathology. MIDL 2024.

[B] van der Walt S. et al. scikit-image: image processing in Python. PeerJ 2:e453, 2014.

[C] Janssen A.F.J., Breusegem S.Y., Larrieu D. Current Methods and Pipelines for Image-Based Quantitation of Nuclear Shape and Nuclear Envelope Abnormalities. Cells 11(3):347, 2022.

Reviewer RqSwOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
4/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

Unconditional histopathology image generation remains difficult because existing models like ZoomLDM and PixCell suffer from conditioning collapse, where the generative process degenerates when no class or tissue label is provided. We trace this failure to the geometry of pathology vision foundation model patch-token features, which cluster tightly on a unit hypersphere with strong angular structure and measurable intrinsic curvature. Euclidean flow matching ignores this geometry, producing suboptimal transport paths and degraded sample quality.

Strengths and weaknesses

Strengths

  1. The identification of conditioning collapse in existing histopathology generative models is well-motivated and supported by concrete quantitative diagnostics, including entropy decomposition via Vendi Score and SPEC-diff. The empirical characterization of VFM feature geometry—angular dominance and manifold curvature—provides a principled justification for the Riemannian formulation rather than a post-hoc rationalization.

  2. The bridge-type stochastic perturbation is theoretically grounded. The paper establishes per-token rectifiability on the unit hypersphere, and the vanishing-endpoint property of the sinusoidal noise schedule is well-reasoned. The connection drawn to the Karhunen–Loève expansion of the Brownian bridge lends additional theoretical coherence to the construction.

  3. The anisotropic decoder design is novel and mechanistically interpretable. Coupling the decoder's directional robustness budget to the singular value decomposition of the velocity-field Jacobian is a principled choice, and the superadditive interaction between this component and the stochastic bridge is explicitly verified in the ablation study.

  4. The two-stage ablation cleanly isolates the contribution of each component. The directional Lipschitz contrast and the encoder-dependence study further strengthen the mechanistic claims, providing evidence that the observed gains are not attributable to architectural confounds.

  5. The evaluation protocol is comprehensive, covering both standard metrics computed with ImageNet-pretrained models and pathology-aware variants computed with a histopathology foundation model. The inclusion of foundation-model-based evaluation is particularly valuable, as it accounts for the domain gap between natural and histopathological images that standard FID-based metrics are ill-equipped to capture.

Weaknesses

  1. The paper lacks a downstream evaluation of the generated images as a data augmentation tool, for instance, using synthetic patches to improve performance on a pathology classification task. This experiment is particularly important given that the authors explicitly claim one primary motivation is to supply training data for foundation models. For an unconditional generative model, the most direct demonstration of practical value is whether synthetic data improves a downstream task under constrained conditions, such as a low-data regime. Without such evidence, the practical utility of STREAM beyond the generative metrics in Table 3 remains unsubstantiated.

  2. The paper omits direct numerical comparison with PathDiff[1], DINO-SAE, and Geometry-Aware FM. However, if PathDiff is a conditional model that similarly cannot perform unconditional generation—analogous to the limitation exposed for PixCell in Section 5.2—the authors should state this explicitly, as it would directly reinforce STREAM's core motivation. Noting such structural incompatibilities in the related work discussion would strengthen the paper's positioning without requiring numerical results.

  3. Two core hyperparameters—the maximum noise level and the energy threshold—receive no ablation. For the latter, the value 0.90 is reported in Appendix E without any sensitivity analysis. If these values are inherited from prior work, this should be stated explicitly. If they are new choices introduced by this paper, at least two or three alternative values should be ablated, as both parameters directly govern the geometry of the training objective.

  4. The paper evaluates only UNI as the primary pathology encoder, with DINOv2-L serving as a natural-image-domain negative control. However, the paper's core geometric argument—that L2-normalized patch-token features concentrate on the unit hypersphere with strong angular dominance and intrinsic curvature—applies equally to Virchow2 and Prov-GigaPath. Without at least one additional pathology-domain encoder ablation, it is unclear whether the observed gains are specific to UNI's pretraining or generalise across this model family. The authors should include results for at least one alternative pathology foundation model, or provide a systematic justification for why UNI is the preferred choice.

  5. The paper's discussion of practical application scenarios is insufficient. The authors identify two use cases—cross-institutional data sharing and training data for foundation models—but neither is developed to a level that substantiates the claim. For the former: how would unannotated, unconditionally generated patches be used in downstream research or clinical workflows after cross-institutional transfer? For the latter: is there a lightweight downstream task, such as a small-scale classifier, that can serve as a concrete proxy for the claimed benefit to foundation model training? The authors should expand on these scenarios in the main text or supplementary material. The practical motivation currently reads as aspirational, and even a preliminary demonstration of this kind would considerably strengthen the paper's overall case.

[1] Bhosale, Mahesh, et al. "Pathdiff: Histopathology image synthesis with unpaired text and mask conditions." Proceedings of the IEEE/CVF International Conference on Computer Vision. 2025.

Questions

see "Strengths And Weaknesses"

Limitations

yes

Final justification

Thank you for the authors' response. After reviewing the authors' replies across all sections, I believe all my concerns have been resolved. I strongly recommend that the authors dedicate a specific paragraph in the main text to elaborate in detail on the practical/business applications of unconditional pathology image generation. This would greatly enhance the value of this paper, and is particularly crucial for the emerging field of unconditional pathology image generation. I am raising my score to Accept.

Formatting concerns

N/A

7 comments
Authors · CommentOpenReview ↗

Response to Reviewer RqSw (Part 4/4)

Q4. An additional pathology encoder.

We agree the geometric argument should apply to Virchow2 and Prov-GigaPath, and that UNI alone leaves the question open. We first naively re-ran the pipeline with Virchow2 features on the same LightningDiT-XL backbone, to hold the entire model architecture, configuration, and hyperparameters fixed while the encoder only changed. However, that configuration turned out to be architecturally defective, as Virchow2 emits 1280-dimensional patch tokens while the STREAM deployed LightningDiT-XL has hidden size 1152. UNI at 1024 sits below the hidden size, so the deployed configuration is unaffected and this is a property of the generator we chose, not of VFM/encoder quality.

RAE, which is our Euclidean baseline, reports a similar bottleneck empirically: their Table 3 supports Theorem 1, which establishes a loss lower bound for diffusion models of the form Bf(Axt,t)Bf(Ax_t,t) when the hidden dimension satisfies d<nd{<}n. While we cannot theoretically and yet empirically verify that this applies exactly to STREAM (as STREAM's setup is different from RAE's) at this stage, it does highlight the same architectural bottleneck arising from a hidden dimension narrower than the embedding dimension in latent diffusion models, which is a likely hypothesis at this point.

Therefore, we are currently retraining at LightningDiT-1.0B (hidden size 1536 > 1280), which does not have this theoretical issue. We will update and report the Virchow2 numbers as soon as the run completes, within the discussion period. We will also confirm if the analysis above is indeed true in the revision if needed, because for now, this is a hypothetical explanation of why STREAM's identical architecture, configuration, and hyperparameters cannot be ablated with simply replacing UNI with Virchow 2. However, this hidden size change causes the model size to become much larger as LightningDiT-XL is 676M params while LightningDiT-1p0b is 1.03B params. Following this, the SVD cache and the ViT based anisotropic decoder also increases in size and hence total training time and memory usage increases as well. Therefore, the ideal hyperparameters for Virchow 2 would likely be different from UNI's when applying this to STREAM, which is a caveat that we hope the reviewers will understand.

On a parallel note, to explain why we chose UNI, the choice is made in §3.2 of the main text on intrinsic-geometry grounds, following Xiong et al. [L]. The spectrum of the ℓ2\ell_2-normalized feature covariance on TCGA-BRCA gives effective rank 252 for UNI (d=1024d{=}1024) against 265 for UNI2-h (d=1536d{=}1536). UNI2-h therefore buys 5% more effective rank for 50% more embedding dimension, so UNI carries essentially the same intrinsic content in two-thirds of the space. Also, if our preliminary analysis above holds to be true, this can also in retrospect result in a model that is more efficient (smaller in size / lower FLOPs and throughput).

Q5. Practical application scenarios.

Answered together with Q1.

References

[L] Xiong C. et al. Exploiting Low-Dimensional Manifold of Features for Few-Shot Whole Slide Image Classification. ICLR 2026.

Authors · CommentOpenReview ↗

Response to Reviewer RqSw (Part 3/4)

Q3. Ablations of the maximum noise level and the energy threshold.

We confirm that neither the maximum noise level nor the energy threshold is inherited from prior work (both are our own choices), and we agree they should have been ablated. STREAM carries two distinct noise magnitudes and it is not clear to us which is meant here by the reviewer, so we report both: the bridge noise σmax⁡\sigma_{\max} injected while training the DiT, and the low-energy decoder noise σL\sigma_L injected while training the decoder. All ablations are on TCGA-BRCA with every other hyperparameter held fixed (rFID/gFID). The bridge-noise sweep uses the full decoder schedule; the decoder-noise and threshold ablations use a matched 45K decoder budget.

Bridge noise, maximum magnitude σmax⁡\sigma_{\max}:

σmax⁡\sigma_{\max} rFID ↓ gFID ↓
5×10−35\times10^{-3} 3.22 6.93
10−2\mathbf{10^{-2}} (deployed) 2.42 6.61
2×10−22\times10^{-2} 3.69 7.88

We can see the optimum on both metrics is in the middle value, which is the deployed value for STREAM. σmax⁡>0\sigma_{\max}>0 is assumed in the support and rectifiability results (Prop. 2, Thm. 3) rather than derived as necessary, and those results hold for any positive value; the transport perturbation of Prop. 7 then also grows as O(σmax⁡2)O(\sigma_{\max}^2). Therefore, this empirical sweep tells us where the optimum actually sits at.

Decoder noise, low-energy magnitude σL\sigma_L.

This ablation is already in the submission, at App. G of main text, so no further analysis is needed; we reproduce it here for the reviewer's convenience, with σH=0.002\sigma_H{=}0.002 and τ=0.90\tau{=}0.90 held fixed:

σL\sigma_L rFID ↓ gFID ↓
0.01 2.41 7.39
0.02 (deployed) 3.52 6.86
0.03 5.12 7.97

The STREAM deployed magnitude also sits at the middle optimum on gFID. Raising σL\sigma_L worsens rFID monotonically, since the decoder is trained to denoise ever larger perturbations, while gFID is non-monotone. Then, as requested, at the same matched 45K decoder budget as σL\sigma_L above, we perform the ablation on the energy threshold τ\tau.

Energy threshold τ\tau

τ\tau rFID ↓ gFID ↓
0.90 (deployed) 3.52 6.86
0.80 5.81 8.80

Lowering it to 0.80 costs 2.29 rFID and 1.94 gFID, so τ=0.90\tau{=}0.90 is not arbitrary. This is most likely because lower τ\tau shrinks k∗k^\ast and moves the least energetic of the retained directions into the low-energy subspace, where they meet the far larger σL\sigma_L. More values of τ\tau can be ablated and included in the revision, if needed.

Authors · CommentOpenReview ↗

Response to Reviewer RqSw (Part 2/4)

Q1. Downstream evaluation as a data-augmentation tool (continued).

Since classification is a fairly saturated task in histopathology, we also run an inherently harder downstream task on the same pretrained encoders. HEST [G] pairs H&E tiles with matched spatial transcriptomics; the task is to predict, from a tile's frozen embedding alone, how strongly each of the top-50 highly-variable genes (HVGs) is expressed in that tile. We fit a ridge regression and a gradient-boosted regressor (XGBoost) on the embeddings and report the average Pearson correlation coefficient (PCC), per gene and averaged over the 50 genes and the folds, again on the official uncontaminated split.

COADREAD / BRCA Rand. STREAM Real
HEST, ridge (avg PCC) 0.144 / 0.163 0.284 / 0.313 0.280 / 0.333
HEST, XGBoost (avg PCC) 0.128 / 0.145 0.247 / 0.307 0.269 / 0.283

This is the stricter probe, since morphology predicts expression only insofar as the embedding has captured real tissue biology rather than texture. STREAM again performs on par with real, which is the more telling evidence that its images carry genuine biological fidelity.

On how unannotated, unconditionally generated patches would be used after cross-institutional transfer (Q5).

While we cannot name a specific clinical pinch point with confidence, two binding constraints that STREAM can help resolve are clinically documented together [H] (integrated quotation). First, respecting patient privacy and obtaining approval for data use "may reduce the options for the reuse of existing data for AI development, and may lead to increased costs to arrive at the required numbers of cases". Secondly, "collecting annotations remains an obstruction to the scaling of CPATH algorithms", since manual annotation costs pathologist time and clinical annotation needs access to reports, records or registries.

A generator like STREAM transfers morphology with biological fidelity without transferring any patient's actual tissue, which addresses the first. And because what is scarce is annotation rather than images, an unconditional generator like STREAM matches that constraint (unlike current state-of-the-art conditional histopathology image generators that would require exactly the labels that are hardest to obtain). The self-supervised result above is that workflow end-to-end shown as a proof-of-concept. For an example use case, for data sharing, the data-providing institution can pretrain a foundation model/encoder on its images to transfer synthetic tiles. The data-receiving institution can then receive the synthetic tiles to also train a foundation model/encoder for downstream task usage without violating patient privacy regulations.

Q2. Comparison with PathDiff, DINO-SAE and Geometry-Aware Image FM.

We thank the reviewer for pointing PathDiff [I] out, and will cite it in the revision. Its inference conditioning set is restricted to text-only, mask-only, or both; the all-null branch is a training-time classifier-free-guidance step only, and no de novo unconditional generation is presented. It belongs with ZoomLDM and PixCell as a conditional, VAE-latent method, which reinforces rather than weakens our motivation. DINO-SAE (now HAE) [J] and Geometry-Aware Image FM [K] remain unavailable for numerical comparison, but we can position them as mentioned in the main text. Both use deterministic SLERP paths with velocity prediction and an intrinsic tangent-space loss, while STREAM trains on a stochastic bridge rather than a deterministic path, with x-prediction and a chord loss.

References

[G] Jaume G. et al. HEST-1k: A Dataset for Spatial Transcriptomics and Histology Image Analysis. NeurIPS 2024.

[H] van der Laak J., Litjens G., Ciompi F. Deep Learning in Histopathology: The Path to the Clinic. Nature Medicine 27:775–784, 2021.

[I] Bhosale S. et al. PathDiff: Histopathology Image Synthesis with Unpaired Text and Mask Conditions. ICCV 2025.

[J] Chang H., Cha B., Ye J.C. HAE: Hyperspherical Autoencoder for High-Fidelity Image Reconstruction and Generation. arXiv:2601.22904, 2026 (previously titled DINO-SAE).

[K] Lee J., Kim K., Lee J. Geometry-Aware Image Flow Matching. ICML 2026.

Comments on the paper

6 comments
Authors · CommentOpenReview ↗

Official Comment to all reviewers and the AC: Additional results since initial submission (Part 4/4)

Noise-schedule shape (Stage 1).

We perform the noise schedule ablation experiment of STREAM's DiT training. STREAM deploys kl1 (Karhunen-Loeve), σ(t)=σmax⁡sin⁡(πt)\sigma(t)=\sigma_{\max}\sin(\pi t) (Def. 1, §4.2 of main text). Here kl1 is put against si and ve (stochastic interpolants and variance-exploding), two published schedules proposed and validated in Euclidean settings, so the below statement is about running them on a sphere. All four share the same SLERP backbone, the tangent Gaussian and the exponential map; only the scalar amplitude σ(t)\sigma(t) changes. kl1 and kl2 truncate the Karhunen-Loeve expansion of the standard Brownian bridge at one and two modes, eigenfunctions sin⁡(nπt)\sin(n\pi t); under the common normalization both peak at σmax⁡\sigma_{\max}, so the pair tests first-mode sufficiency. si is the stochastic interpolant noise profile γ(t)=2t(1−t)\gamma(t)=\sqrt{2t(1-t)} ([L], Eq. 1.1), rescaled so its peak is also σmax⁡\sigma_{\max} and the comparison is one of shape rather than amplitude. ve is an unpinned monotone control: σmax⁡t\sigma_{\max}\sqrt{t} is the marginal standard deviation of the constant- diffusion member of the VE family ([M], Eq. 9), and is a representative unpinned profile rather than the schedule VE implementations usually deploy.

Schedule σ(t)\sigma(t) σ(1)\sigma(1) ∫01 ⁣σ2\int_0^1\!\sigma^2 rFID gFID
kl1 (Karhunen-Loeve, mode n=1n{=}1; deployed) σmax⁡sin⁡(πt)\sigma_{\max}\sin(\pi t) 00 12\tfrac12 2.42 6.61
kl2 (Karhunen-Loeve, modes n=1,2n{=}1,2) σmax⁡sin⁡2πt+14sin⁡22πt\sigma_{\max}\sqrt{\sin^2\pi t+\tfrac14\sin^2 2\pi t} 00 58\tfrac58 3.33 5.64
si (stochastic interpolant) σmax⁡⋅2t(1−t)\sigma_{\max}\cdot2\sqrt{t(1-t)} 00 23\tfrac23 3.28 7.15
ve (variance exploding, unpinned) σmax⁡t\sigma_{\max}\sqrt{t} σmax⁡\sigma_{\max} 12\tfrac12 4.65 10.58

Both kl1 and kl2 beat si and ve on gFID, while being better or similar for rFID. Therefore, for STREAM, we retain kl1 because it is the schedule the initial theory is stated for, but gFID wise, kl2 is another candidate that could be utilized. We show that noise schedule selection isn't random, as it has a significant influence on downstream performance of the model.

We hope that these additional experiments and its positive results showcase the strengths and further help reviewers understand the mechanism and the significance of our work.

References

[L] Albergo M.S., Boffi N.M., Vanden-Eijnden E. Stochastic Interpolants: A Unifying Framework for Flows and Diffusions. JMLR 26(209):1-80, 2025 (arXiv:2303.08797).

[M] Song Y., Sohl-Dickstein J., Kingma D.P., Kumar A., Ermon S., Poole B. Score-Based Generative Modeling through Stochastic Differential Equations. ICLR 2021 (arXiv:2011.13456).

Authors · CommentOpenReview ↗

Official Comment to all reviewers and the AC: Additional results since initial submission (Part 3/4)

Prediction target and loss (Stage 1).

The loss is written in x-space (chord) or v-space (geodesic) and the network predicts the endpoint or the velocity, giving four combinations plus a control. Output parameterization and loss weighting are one joint choice; in flat space the x-, v- and noise-losses differ only by a scalar reweighting with one population minimizer, so the pairing is benign there. Predicting the clean endpoint is likewise established ([C]). On Sd−1\mathcal S^{d-1} the metric is the Euclidean inner product restricted to the tangent space, so a velocity loss admits no extrinsic-versus-intrinsic choice and the chord- versus-geodesic choice arises only once endpoints are regressed. To our knowledge, every Riemannian flow-matching method we know of scores its prediction in tangent space through the logarithm map, whether the network emits a velocity (RFM [D]) or an endpoint; the one exception, [E], regresses endpoints under a geodesic loss, on 2- and 3-dimensional factors. However, none regresses endpoints in the ambient chord metric.

RFM in images/high dimension is not itself new, but running this ablation at high dimension is. HAE [F], the one system we know of at our manifold dimension, trains on a product of 256 spheres at d=1024d{=}1024, and scores a predicted tangent velocity against the target, ∥vtan⁡−ut∥2\lVert v_{\tan}-u_t\rVert^2 with a radial penalty: canonical v-loss on v-prediction, which is the parameterization of the second row below. The other published RFM image models, RJF [G] and Geometry-Aware Image FM [H], likewise use the canonical velocity loss as well. No high-dimensional (image) RFM method has run the full four-way comparison, so we put it forward as a small but real contribution of our work.

Parameterization rFID gFID
x loss (chord) + x-prediction (ours) 2.42 6.61
Standard RFM: v loss (geodesic) + v-prediction 4.78 7.84
x loss (chord) + v-prediction 4.73 11.26
v loss (geodesic) + x-prediction 3.12 12.57

STREAM's deployed pairing of chord loss, or x-loss and x-prediction, beats standard RFM on both rFID and gFID metrics. This also confirms the recent general literature ([C], [I], [J], [K]) on flow matching that x-prediction is generally the best recognized parameterization for flow matching, albeit these papers are all trained slightly differently and applied in different domains. Here we also show that in RFMs, different combinations of loss functions and predictions of the trained model can result in wildly different downstream results.

References

[C] Li T., He K. Back to Basics: Let Denoising Generative Models Denoise. CVPR 2026 (arXiv:2511.13720).

[D] Chen R.T.Q., Lipman Y. Flow Matching on General Geometries. ICLR 2024 (arXiv:2302.03660).

[E] Zaghen O. et al. Riemannian Variational Flow Matching for Material and Protein Design. ICLR 2026 (arXiv:2502.12981).

[F] Chang H., Cha B., Ye J.C. Hyperspherical Autoencoder for High-Fidelity Image Reconstruction and Generation. arXiv:2601.22904, 2026 (v1: DINO-SAE).

[G] Kumar A., Patel V.M. Learning on the Manifold: Unlocking Standard Diffusion Transformers with Representation Encoders. ECCV 2026 (arXiv:2602.10099).

[H] Lee J., Kim K., Lee J. Geometry-Aware Image Flow Matching. ICML 2026 (arXiv:2605.25294).

[I] Ma J. et al. Multi-Scale Generative Modeling with Heat Dissipation Flow Matching. arXiv:2605.19371, 2026.

[J] Gagneux A. et al. Training Flow Matching: The Role of Weighting and Parameterization. arXiv:2603.06454, 2026.

[K] Hong J. et al. Binary Flow Matching: Prediction-Loss Space Alignment for Robust Learning. arXiv:2602.10420, 2026.

Authors · CommentOpenReview ↗

Official Comment to all reviewers and the AC: Additional results since initial submission (Part 2/4)

VFM-controlled comparison: all six methods/baselines on the same UNI encoder.

We re-report Table 3 of main text with UNI features as the generative latent (STREAM, RAE and SVG), where the main text reported RAE and SVG with its original DINOv2-L encoder. PixCell and ZoomLDM utilize VAEs as their latents with UNI being conditioned, and we also added REPA-E [A] as the intermediate case as its latents are VAE-based but uses UNI as an alignment target. Therefore, every method in the result table now uses UNI.

Specifically in REPA-E, the generative latent is VAE-based, not UNI; UNI enters through the representation-alignment loss that trains the diffusion model and the VAE end to end, so UNI shapes the generated space indirectly rather than being it. RAE and SVG therefore remain the clean encoder- controlled tests of our claim. SPIDER-skin [B] is a third dataset, a different organ (skin H&E images) from a non-TCGA source, with all six methods retrained from scratch.

gFID, encoder = UNI TCGA-BRCA TCGA-COADREAD SPIDER-skin
STREAM 6.61 7.68 9.19
ZoomLDM 7.43 8.09 11.14
REPA-E 28.57 13.41 18.00
RAE 15.84 19.64 16.52
SVG 17.37 23.64 22.24
PixCell 104.18 127.24 453.28

Across three organ datasets, two TCGA cohorts and one non-TCGA source, STREAM outperforms every baseline on generation quality: it holds the best gFID on TCGA-BRCA, on TCGA-COADREAD and on SPIDER-skin. STREAM holds first place on all three, across two organs, two cohorts and two sources, which is the robustness a method needs to be applied across diverse histopathology datasets rather than tuned to one. As mentioned above, the RAE and SVG entries are retrained on UNI, so they are not the main text's numbers for TCGA-BRCA and COADREAD.

Reconstruction FID for the same runs, for completeness:

rFID, encoder = UNI TCGA-BRCA TCGA-COADREAD SPIDER-skin
STREAM 2.42 5.64 4.65
ZoomLDM 4.88 4.12 7.85
REPA-E 26.83 13.58 17.76
RAE 6.60 6.31 7.12
SVG 2.16 1.81 1.30
PixCell 2.88 2.58 3.32

SVG is ahead of STREAM on rFID on all three datasets, PixCell on two and ZoomLDM on TCGA-COADREAD, and none of them converts that into generation quality, and the gap is much bigger. However, favoring these models over STREAM because of only rFID would not be reasonable, as SVG and PixCell report gFID values that are significantly higher than STREAM in all three datasets, while STREAM's rFID gap to those are much lower. Furthermore, we believe that a generation model should first minimize gFID and then strive to minimize rFID as the main task is high-fidelity generation to the trained dataset, not pure reconstruction.

What is systematic is that STREAM extracts more from the same UNI features than the Euclidean methods that use the same latent, RAE and SVG. PixCell and ZoomLDM train directly on VAE features so they are not as comparable, but they are relevant regardless as domain-specific state-of-the-art comparisons.

References

[A] Leng X., Singh J., Hou Y., Xing Z., Xie S., Zheng L. REPA-E: Unlocking VAE for End-to-End Tuning of Latent Diffusion Transformers. ICCV 2025 (arXiv:2504.10483).

[B] Nechaev D., Pchelnikov A., Ivanova E. SPIDER: A Comprehensive Multi-Organ Supervised Pathology Dataset and Baseline Models. arXiv:2503.02876, 2025.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…