Subject-Relative Micro-Motion and Sleep Dynamics for Near-Infrared Video Sleep Staging
Kunmin Jang, You Rim Choi, Hun Heo, Heonjun Lee, Suahn Bae, Dongik Park, Hyun-Woo Shin, Hyung-Sin Kim
NeurIPS 2026
TL;DR. We study PSG-defined sleep staging from NIR video alone and show that subject-relative micro-motion learning with full-night sleep dynamics enables video-only staging without explicit physiological proxy reconstruction.
Abstract. Near-infrared (NIR) video is a promising modality for contactless sleep monitoring, but recent video-based sleep staging methods often use it as a route to reconstructed respiratory/cardiac proxies or cross-modal physiological representations. We study video-only sleep staging under labels defined by polysomnography (PSG), where the model infers sleep stages from NIR video alone without explicit physiological proxy reconstruction or auxiliary physiological signal supervision. This tests whether NIR video itself can provide informative sleep-stage evidence, rather than only serving as an input for recovering physiological proxies. We propose ViNUSS (Video-Native Unmediated Sleep Staging), a framework that combines subject-relative micro-motion learning with full-night sleep dynamics modeling. Spatially anchored pre-spatial micro-motion encoding preserves localized temporal variation with its spatial context. Within-subject stage contrast learns stage cues with respect to each subject’s night-specific baseline. Two-scale sleep dynamics modeling captures within-epoch motion evolution and organizes epoch-level evidence into a coherent full-night sleep-stage trajectory. On 475 overnight NIR recordings (∼3,250 hours), ViNUSS achieves 0.80 accuracy and 0.78 macro-F1 for four-class sleep staging, and adding reconstructed or contact-sensor waveform proxies to its representation yields no measurable improvement. Interpretability analysis suggests attention to thoraco-abdominal periodic motion and gross body movements associated with arousals and position changes. These results support NIR video as an independently informative modality for PSG-defined sleep-stage estimation.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:42 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
Reviewers find the use case real and the recording conditions genuinely demanding. They also point to the scale of the clinical cohort as a strength unusual for this modality. KeGQ and 4pmZ describe the video-only formulation as original and practical, since it avoids the failure modes of reconstructing physiological proxies under occlusion and anonymization. uFaX notes that the design choices follow from documented properties of the data, pointing to the diagnostic analyses that motivate each component. 4pmZ rates significance excellent.
Concerns: Reviewers ask for evaluation beyond the single cohort, noting that the work is entirely intra-dataset and that robustness to domain shift is therefore unverified. uFaX frames this strongly and states that an argument about the modality itself depends on generalization beyond one hospital. KeGQ and 4pmZ request analysis stratified by disease severity, given that a large share of the cohort has severe sleep apnea, and both want to know whether pathological respiratory motion is confused with stage-relevant motion. KeGQ and 4pmZ also raise reproducibility, asking for release of code, weights, or a demonstration.
Reviewer uFaX identifies a gap in the argument: the paper says that learning directly from video is preferable to extracting physiological proxies, but never tests whether the video alone carries the evidence. The reviewer proposes a direct experiment that would settle this and also notes that all evaluation rests on one split with no variance estimates or significance tests. 4pmZ questions whether the comparison against the proxy-based baseline is fair given differences in what each method was trained on, and finds the split protocol underspecified. KeGQ raises the low frame rate and the missing optical configuration, and asks for failure-mode analysis.
The authors should address:
- the proxy-input experiment that would test the video-only argument directly
- variance estimates or significance tests
- explicit pointers to the split description and the stratified appendix
- reconciliation of the baseline comparison and the other details on the reviews.
The authors addressed the main concerns raised during review. Most importantly, the proxy-fusion ablation directly addresses Reviewer uFaX’s central concern. Adding the reconstructed breathing proxy reduces performance. Adding clean contact-sensor breathing and cardiac waveforms provides no measurable improvement over video-only ViNUSS. The appropriate conclusion is that the evaluated waveform proxies provide no measurable incremental benefit to the video representation. The authors also added subject-level bootstrap confidence intervals for all methods. They strengthened the SleepVST comparison by fine-tuning its waveform encoder on KVSS.
The authors evaluated transfer to two held-out KVSS sites. Zero-shot performance drops clearly at both sites. Site-specific adaptation recovers much of the loss, although macro-F1 remains below the Hospital A result. This gives useful evidence on cross-site transfer and identifies an important limitation. The authors also clarified that the split is subject-independent and temporally disjoint. They extended the analysis of OSA severity to individual respiratory events. Their failure-mode analysis covers boundary timing, blanket coverage, sleep position, breathing regularity, respiratory events and limb movement. The main remaining error pattern is Deep-to-Light confusion. The discussion also clarified the 5 fps constraint and the available information about the optical setup. The authors committed to release the code, preprocessing pipeline and trained checkpoints upon acceptance.
The reviewer follow-up is consistent with acceptance. Reviewer uFaX considers the primary concern addressed. Reviewer KeGQ states that most concerns were addressed and votes for acceptance. Reviewer 4pmZ recommends acceptance after the additional validation and ablation results. I therefore maintain Accept (poster).
For the camera-ready, the paper should include the experiments and analyses added during discussion together with their limitations. In particular, it should state the cross-site gap clearly and use the narrower conclusion that the evaluated waveform proxies provide no measurable incremental benefit. It should also add clear main-text pointers to the split description and stratified analyses. The authors should release the code, preprocessing pipeline and trained checkpoints as committed.
Final justification
The proxy-fusion ablation directly addresses the main concern. Neither reconstructed nor clean contact-sensor waveform proxies improve over video-only ViNUSS. Subject-level bootstrap confidence intervals were added across methods. The SleepVST baseline was strengthened through fine-tuning on KVSS.
Cross-site evaluation on two held-out KVSS sites shows a clear zero-shot transfer gap. Site-specific adaptation recovers much of the loss. The authors also clarified the data split and extended the clinical subgroup and failure-mode analyses.
Reviewer uFaX considers the primary concern addressed. Reviewer KeGQ votes for acceptance. Reviewer 4pmZ recommends acceptance after the new analyses. The remaining limitations, especially the cross-site gap, do not change my recommendation.
Read meta-review
Meta-review
Reviewers find the use case real and the recording conditions genuinely demanding. They also point to the scale of the clinical cohort as a strength unusual for this modality. KeGQ and 4pmZ describe the video-only formulation as original and practical, since it avoids the failure modes of reconstructing physiological proxies under occlusion and anonymization. uFaX notes that the design choices follow from documented properties of the data, pointing to the diagnostic analyses that motivate each component. 4pmZ rates significance excellent.
Concerns: Reviewers ask for evaluation beyond the single cohort, noting that the work is entirely intra-dataset and that robustness to domain shift is therefore unverified. uFaX frames this strongly and states that an argument about the modality itself depends on generalization beyond one hospital. KeGQ and 4pmZ request analysis stratified by disease severity, given that a large share of the cohort has severe sleep apnea, and both want to know whether pathological respiratory motion is confused with stage-relevant motion. KeGQ and 4pmZ also raise reproducibility, asking for release of code, weights, or a demonstration.
Reviewer uFaX identifies a gap in the argument: the paper says that learning directly from video is preferable to extracting physiological proxies, but never tests whether the video alone carries the evidence. The reviewer proposes a direct experiment that would settle this and also notes that all evaluation rests on one split with no variance estimates or significance tests. 4pmZ questions whether the comparison against the proxy-based baseline is fair given differences in what each method was trained on, and finds the split protocol underspecified. KeGQ raises the low frame rate and the missing optical configuration, and asks for failure-mode analysis.
The authors should address:
- the proxy-input experiment that would test the video-only argument directly
- variance estimates or significance tests
- explicit pointers to the split description and the stratified appendix
- reconciliation of the baseline comparison and the other details on the reviews.
The authors addressed the main concerns raised during review. Most importantly, the proxy-fusion ablation directly addresses Reviewer uFaX’s central concern. Adding the reconstructed breathing proxy reduces performance. Adding clean contact-sensor breathing and cardiac waveforms provides no measurable improvement over video-only ViNUSS. The appropriate conclusion is that the evaluated waveform proxies provide no measurable incremental benefit to the video representation. The authors also added subject-level bootstrap confidence intervals for all methods. They strengthened the SleepVST comparison by fine-tuning its waveform encoder on KVSS.
The authors evaluated transfer to two held-out KVSS sites. Zero-shot performance drops clearly at both sites. Site-specific adaptation recovers much of the loss, although macro-F1 remains below the Hospital A result. This gives useful evidence on cross-site transfer and identifies an important limitation. The authors also clarified that the split is subject-independent and temporally disjoint. They extended the analysis of OSA severity to individual respiratory events. Their failure-mode analysis covers boundary timing, blanket coverage, sleep position, breathing regularity, respiratory events and limb movement. The main remaining error pattern is Deep-to-Light confusion. The discussion also clarified the 5 fps constraint and the available information about the optical setup. The authors committed to release the code, preprocessing pipeline and trained checkpoints upon acceptance.
The reviewer follow-up is consistent with acceptance. Reviewer uFaX considers the primary concern addressed. Reviewer KeGQ states that most concerns were addressed and votes for acceptance. Reviewer 4pmZ recommends acceptance after the additional validation and ablation results. I therefore maintain Accept (poster).
For the camera-ready, the paper should include the experiments and analyses added during discussion together with their limitations. In particular, it should state the cross-site gap clearly and use the narrower conclusion that the evaluated waveform proxies provide no measurable incremental benefit. It should also add clear main-text pointers to the split description and stratified analyses. The authors should release the code, preprocessing pipeline and trained checkpoints as committed.
Final justification
The proxy-fusion ablation directly addresses the main concern. Neither reconstructed nor clean contact-sensor waveform proxies improve over video-only ViNUSS. Subject-level bootstrap confidence intervals were added across methods. The SleepVST baseline was strengthened through fine-tuning on KVSS.
Cross-site evaluation on two held-out KVSS sites shows a clear zero-shot transfer gap. Site-specific adaptation recovers much of the loss. The authors also clarified the data split and extended the clinical subgroup and failure-mode analyses.
Reviewer uFaX considers the primary concern addressed. Reviewer KeGQ votes for acceptance. Reviewer 4pmZ recommends acceptance after the new analyses. The remaining limitations, especially the cross-site gap, do not change my recommendation.
1 comment
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 2/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- use_inspired
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper studies four-class sleep staging (Wake / Light / Deep / REM) from near-infrared (NIR) video alone, under labels defined by polysomnography (PSG). Unlike prior NIR-video work, proxy-first methods that first reconstruct respiratory/cardiac waveforms, or methods that lean on EEG supervision via teacher distillation or cross-modal retrieval, the proposed framework, ViNUSS, stages directly from a learned video representation with no proxy reconstruction and no EEG-derived supervision. It comprises three parts: a Pixel-Wise Temporal Encoder (PTE) that applies short temporal convolutions per spatial location before spatial mixing; an Intra-Subject Discriminability Loss (ISDL) that contrasts stages within a single overnight recording to suppress subject-dominant variation; and a two-scale Sleep Dynamics Module (SDM) that summarizes within-epoch motion (ShortMamba) and models the full-night trajectory (bidirectional LongMamba). Evaluation is on KVSS (475 overnight recordings, ~3,250 hours, far-field, occluded, face-anonymized), where ViNUSS reaches 0.80 accuracy / 0.78 macro-F1.
Strengths and weaknesses
Strengths:
-
Real, well-matched use case. Contactless scalable sleep monitoring is a genuine clinical need, and KVSS is a realistic, punishing deployment setting. The design choices are tied to documented properties of this data: PTE is motivated by sleep-relevant motion being weak and spatially localized and getting diluted under spatial downsampling; ISDL is motivated directly by the t-SNE analysis (Fig. 2b) showing epoch embeddings cluster by subject rather than stage; SDM reflects the sequential structure of clinical scoring.
-
Strong motivation/diagnostic analysis and sensible proxy-free framing. Figures 1–2 show why video-extracted respiration deviates from contact belts under occlusion/movement, and why a naive 3D CNN attends to static high-contrast structures instead of thoraco-abdominal motion. The proxy-free formulation, plus the within-subject sampling semantics of ISDL, is a well-motivated combination that removes a real failure mode of prior pipelines (rPPG/respiratory extraction breaking under face anonymization and bedding occlusion).
Weakness:
-
The central claim is not validated. The paper's central claim is that learning directly from video is preferable to extracting physiological proxies. The supporting comparison (Table 1) beats a re-implemented SleepVST given oracle contact-sensor breathing/cardiac waveforms plus an optical-flow motion feature (0.78 vs 0.73 MF1). But the paper never validates whether the video itself provide informative sleep-stage evidence. A clean, low-cost experiment would be feeding reconstructed (or oracle) proxies as additional inputs together with video and show that performance does not improve.
-
No variance, single split, single site. All evaluation is one split at one hospital, with no variance reported and no cross-site transfer evaluated. The scale of the dataset (475 subjects) is relatively small.
Questions
-
Can you report an ablation feeding reconstructed and/or oracle physiological proxies (BW/CW) as additional inputs to ViNUSS. If the sleep staging performance does not improve, this would directly support the claim that NIR video already encodes the physiological evidence.
-
Can you provide any variance estimate or significance tests?
-
Is any cross-site or cross-dataset evaluation possible, given the modality-level claim depends on generaliation beyond one hospital?
-
How does ViNUSS compare to a simple clinical/wearable baseline a practitioner would realistically weigh against a camera system?
Limitations
yes
Final justification
The author's rebuttal addressed my primary concerns.
Formatting concerns
None
6 comments
Rebuttal
We thank the reviewer for a careful and constructive review. We address the weaknesses and each question below, with new results where these are complete and the setup where experiments are still running.
[W1 / Q1] Central claim not validated, and request for a proxy-fusion ablation
To test whether the video itself provides informative sleep-stage evidence, we designed two experiments, reported in (1) and (2) below.
(1) Staging from directly measured thoracic and abdominal effort.
The video carries respiration-related motion around the thoraco-abdominal region (Fig. 1a), and SVECAM indicates ViNUSS attends to it (Fig. 6a). Effort belts measure the corresponding motion directly, without attenuation from camera distance, viewing angle, or bedding. This asks whether the physiological evidence in video is comparable to what direct measurement provides.
We train two recent multivariate time-series models on KVSS and pass their epoch representations to the same SDM used in ViNUSS. The split, labels, and evaluation protocol are identical across rows.
Table R1. Four-class staging from ground-truth breathing waveforms (BW*). Unlike Table 1, both thoracic and abdominal channels are supplied.
| Method | Input | Acc | κ | MF1 |
|---|---|---|---|---|
| ModernTCN [1] + SDM | BW* | 0.80 | 0.67 | 0.76 |
| MambaSL [2] + SDM | BW* | 0.77 | 0.63 | 0.72 |
| ViNUSS | Video only | 0.80 | 0.68 | 0.78 |
Video-only ViNUSS is at least as strong on every metric. This parity does not imply the two carry identical information. SVECAM also shows that when larger body movements occur, ViNUSS can attend to them as well as to respiration-related motion (Fig. 6b), which belt waveforms do not represent. Experiment (1) therefore addresses the concern raised. NIR video provides informative sleep-stage evidence in its own right, rather than serving only as a degraded route to respiratory motion.
(2) Requested proxy-fusion experiment.
We are running this now. A waveform encoder following SleepVST produces an epoch-level representation, which is concatenated with the ViNUSS video representation. The combined embedding then feeds the epoch classifier and SDM exactly as the video representation does in ViNUSS, so the pipeline is unchanged apart from the added waveform features, and reported numbers will be measured after SDM. The waveform encoder is additionally fine-tuned on KVSS. Because faces are anonymized, rPPG-based cardiac recovery is unavailable, so cardiac waveform (CW) comes from the contact sensor in all conditions, and the breathing waveform is evaluated both reconstructed from video (BW) and as a contact-sensor oracle (BW*).
We will report the numbers as soon as they are available.
Our claim is that face-anonymized NIR video is independently informative for PSG-defined sleep staging and reaches strong performance without reconstructing waveforms at inference; consistent with this, the abstract and conclusion describe it as an "independently informative and complementary modality", and §5 flags integration with physiological signals as future work. We will make this intent clearer in the paper.
[W2 / Q2] No variance reported on a single split
We report subject-level nonparametric bootstrap confidence intervals (CIs), a common way to estimate variance when only a single held-out cohort is available [3]. The 70 test subjects are resampled with replacement over 5,000 iterations. Subjects rather than epochs are the resampling unit, since epochs within one night are strongly correlated and cluster-level resampling is appropriate under this dependence [4]. This estimates how much results would move had the test cohort been a different draw of patients, the uncertainty most relevant to a modality-level claim.
Table R2. Four-class performance with 95% CIs, applied identically to ViNUSS and baselines.
| Model | Accuracy | MF1 | κ |
|---|---|---|---|
| SleepVST (BW*+CW*+M) | 0.784 [0.763, 0.802] | 0.726 [0.698, 0.751] | 0.635 [0.599, 0.667] |
| MambaSL (BW*) | 0.773 [0.747, 0.797] | 0.721 [0.688, 0.752] | 0.628 [0.586, 0.666] |
| ModernTCN (BW*) | 0.800 [0.778, 0.822] | 0.761 [0.734, 0.787] | 0.673 [0.636, 0.708] |
| ViNUSS (video) | 0.804 [0.784, 0.823] | 0.777 [0.754, 0.797] | 0.684 [0.650, 0.713] |
Intervals are narrow, roughly 0.04 wide for accuracy and MF1.
This also speaks to significance. The MF1 intervals for ViNUSS and the full-oracle SleepVST variant in Table 1 do not overlap, a conservative indication that the margin is not explained by sampling variation. The signal models from [W1 / Q1] overlap substantially with ViNUSS, consistent with the parity described there.
Per-stage intervals are widest for Deep (F1 0.674 [0.622, 0.720]) and tightest for Light (0.834 [0.814, 0.853]), following from Deep being the sparsest stage.
On the single split, the 335/70/70 division follows the KVSS dataset paper [5], keeping our numbers comparable to other work on the same cohort. We will state this explicitly in the camera-ready, since the wording in Appendix A.1 may read as if we designed it ourselves.
[W2 / Q3] Single-site evaluation with no cross-site transfer
On scale, prior video-based staging used single cohorts of at most 50 subjects (Table 1). At 475 subjects Hospital A is roughly an order of magnitude larger, though single-site evaluation remains a real limitation regardless of cohort size.
Cross-site evaluation is possible and we are running it. KVSS contains two further sites never used in training.
Table R3. Acquisition setup at the three KVSS sites. Sample frames from B and C will be added to Appendix A.
| Site | Patients | Camera angle | Distance | Department | Note |
|---|---|---|---|---|---|
| A (training) | 475 | 45° | 3.5 m | otolaryngology | |
| B (held out) | 205 | 45° | 3.0 m | neurology | bed oriented diagonally |
| C (held out) | 256 | 30° | 3.0 m | otolaryngology |
These were not recorded under a shared protocol. Viewing angle and distance change the apparent scale and direction of the same thoraco-abdominal displacement, and bed orientation changes where in the frame it appears. They also draw on different referring departments, so the patient populations differ as well. Each site was scored by its own technicians, so some label variability across sites is possible [6].
For adaptation we follow the Hospital C split defined in the dataset paper [5] and use a matched design at B, so both sites receive comparable amounts of site-specific data. Adaptation subjects are disjoint from evaluation subjects, and zero-shot results use the same evaluation subjects so the settings compare directly.
We evaluate two settings. The first adapts SDM only, recalibrating full-night structure to the new site without touching the extractor. The second additionally fine-tunes the representation module so the extractor adapts to the new camera geometry.
We will report zero-shot and both settings with bootstrap CIs during this period. Zero-shot shows whether the model transfers as it stands, and the adaptation settings separate how much of any gap is calibration to the acquisition setup from what does not transfer at all. §5 notes that broader validation across clinical sites remains important, and these experiments are a first step in that direction.
[Q4] Comparison against a clinical or wearable baseline
ViNUSS targets the longitudinal home monitoring setting motivated in §1, so the realistic alternatives are wearable, nearable, and contactless sensors rather than in-lab PSG. Wrist-worn devices and headband EEG are more mature and the practical choice for a single night in a cooperative adult, but require contact, charging, and sustained compliance, and prolonged wear can itself disturb sleep. Under-mattress sensors remove contact but are tied to one user and location, and acoustic and radar sensing is fully contactless yet sensitive to subject-sensor distance and non-respiratory motion, with limited spatial discrimination when more than one person shares the room (all discussed in §2.1). Video imposes no compliance burden once installed, retains spatial context for where the evidence comes from, and captures behavioral signals such as position changes and arousals.
A numerical comparison is limited by what KVSS contains. There is no concurrent actigraphy, PPG, or headband EEG, so any wearable comparison would cross datasets with different protocols and label distributions. It would also cross populations, since KVSS consists of patients referred for polysomnography, and staging in clinical populations is recognized as a distinct problem [7].
One home-grade contact sensor can be compared directly. Effort belts are used in home sleep apnea testing, and Table R1 stages from those signals on the same subjects, labels, and protocol. Video-only ViNUSS is at least as strong on every metric, without any contact sensor. We do not position this as replacing wearable staging, and §5 notes integration with wearable modalities as future work.
References
[1] Luo & Wang. ModernTCN. ICLR 2024.
[2] Jung & Kim. MambaSL. ICLR 2026.
[3] Efron & Tibshirani. An Introduction to the Bootstrap. Chapman and Hall/CRC, 1994.
[4] Field & Welsh. Bootstrapping clustered data. JRSS-B 69(3), 2007.
[5] Choi et al. Non-contact on-device detection of obstructive sleep apnea from infrared video. Nature Communications, 2026.
[6] Younes et al. Staging sleep in polysomnograms: analysis of inter-scorer variability. JCSM 12(6), 2016.
[7] Fonseca et al. A computationally efficient algorithm for wearable sleep staging in clinical populations. Scientific Reports 13, 2023.
Thank you for the detailed response. I will reassess the concern and my overall evaluation once the pending results are available.
Additional results (1/2)
Following up on our rebuttal, we report the completed results for the two experiments we described as underway. This comment covers the proxy-fusion ablation in [W1 / Q1], and the cross-site evaluation in [W2 / Q3] follows in a second comment.
[W1 / Q1] Additional results: the requested proxy-fusion ablation
As described in the rebuttal, the waveform representation is concatenated with the ViNUSS video representation with everything else unchanged from Table 1. Since face anonymization rules out rPPG, cardiac waveform CW* comes from the contact sensor in both conditions, while the breathing waveform is evaluated both reconstructed from video (BW) and as a contact-sensor oracle (BW*). Neither improves on video-only ViNUSS.
Table R4. Four-class staging with proxy features fused into the ViNUSS video representation. BW is reconstructed from video, and BW* and CW* are contact-sensor waveforms. The waveform encoder is fine-tuned on KVSS. Intervals are subject-level bootstrap 95% CIs, as in Table R2.
| Method | Input / Proxy | Acc | κ | MF1 |
|---|---|---|---|---|
| Proxy fusion | BW + CW* + video | 0.762 [0.739, 0.782] | 0.614 [0.581, 0.644] | 0.721 [0.697, 0.744] |
| Proxy fusion | BW* + CW* + video | 0.802 [0.781, 0.821] | 0.683 [0.651, 0.711] | 0.769 [0.743, 0.792] |
| ViNUSS | Video only | 0.804 [0.784, 0.823] | 0.684 [0.650, 0.713] | 0.777 [0.754, 0.797] |
With the reconstructed breathing waveform, fusion is worse than video alone by 0.042 accuracy, 0.070 κ, and 0.056 MF1, with clearly separated intervals on κ and MF1 and marginally separated intervals on accuracy. This is consistent with Fig. 1, where reconstructed respiration departs from the contact signal in dominant frequency and amplitude under bedding, position changes, and non-respiratory movement, and a channel carrying such error can hurt rather than help. This row is nonetheless the closest to contact-free operation among the configurations tested, and even it is optimistic, since CW* still comes from a contact sensor. Whether better reconstruction would change the picture is answered by the BW* row, which is the limit a perfect video-to-waveform extractor would approach.
Replacing BW with the contact-sensor waveform removes that error, and fusion then becomes indistinguishable from video alone rather than better than it. The differences of −0.002 accuracy, −0.001 κ, and −0.008 MF1 are an order of magnitude smaller than the interval widths. This meets the reviewer's criterion directly. Even given clean contact measurements of both breathing and cardiac activity, and an encoder fine-tuned on our data, the proxy branch adds no benefit we can measure. This supports the claim in the paper, that face-anonymized NIR video is independently informative for PSG-defined sleep staging and reaches this level without reconstructing waveforms at inference.
Table R5. Per-stage F1 for the fusion configurations.
| Method | Input / Proxy | Wake | Light | Deep | REM |
|---|---|---|---|---|---|
| Proxy fusion | BW + CW* + video | 0.738 [0.700, 0.773] | 0.802 [0.781, 0.821] | 0.594 [0.539, 0.645] | 0.751 [0.703, 0.794] |
| Proxy fusion | BW* + CW* + video | 0.787 [0.756, 0.815] | 0.831 [0.812, 0.850] | 0.631 [0.573, 0.685] | 0.829 [0.775, 0.869] |
| ViNUSS | Video only | 0.776 [0.739, 0.810] | 0.834 [0.814, 0.853] | 0.674 [0.622, 0.720] | 0.823 [0.784, 0.856] |
Under the contact-sensor waveform, the per-stage intervals overlap throughout and neither configuration is consistently ahead. The differences are small on Wake, Light, and REM, and larger on Deep at 0.043, which is the sparsest stage (~9%) and the one carrying by far the widest interval of the four. Deep is also the stage the waveform models handle least well on their own. In the confusion matrices of the signal-only models in Table R1, 45 to 53% of true Deep epochs are recovered, with most of the remainder labelled Light, against 68% for video-only ViNUSS. Under the reconstructed waveform all four stages fall together, which is what a degraded input channel looks like rather than an interaction specific to one stage.
We will add Tables R4 and R5 to Appendix D as a proxy-fusion ablation, referenced from §4.2, noting that the configuration closest to contact-free deployment performs worse than video alone, and that oracle waveforms add nothing over video either.
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 4/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper introduces VINUSS, a video-only sleep staging framework using near-infrared (NIR) video. To bypass the limitations of traditional physiological proxy-first reconstruction or cross-modal alignment methods, the authors propose a Pixel-Wise Temporal Encoder (PTE) for localized micro-motion, an Intra-Subject Discriminability Loss (ISDL) for calibration, and a two-scale Mamba-based sequence model to capture full-night sleep dynamics. Evaluated on the large-scale Korea Video Sleep Study (KVSS) dataset, the model demonstrates strong four-class sleep staging performance and smoother trajectory tracking without post-hoc smoothing.
Strengths and weaknesses
Strengths Innovative Paradigm: The paper shifts away from error-prone physiological proxy reconstruction, directly modeling raw spatiotemporal micro-motions from NIR video.
Effective Temporal Modeling: Leveraging a two-scale Mamba architecture successfully incorporates macro-level full-night sleep continuity to stabilize per-epoch predictions.
Substantial Dataset: The framework is validated on a large clinical dataset (KVSS) with 475 overnight recordings, showing strong metrics (0.80 Acc, 0.78 MF1).
Weaknesses Potential Unfairness in Baseline Evaluation: The comparison with SleepVST raises fairness concerns. SleepVST was pre-trained on external datasets (SHHS/MESA), whereas VINUSS benefits from directly training on the target KVSS dataset.
Ambiguity in Data Splitting: The exact cross-validation strategy, temporal data separation protocols, and leakage prevention measures between subjects remain unclear.
Insufficient Reproducibility Support: The exclusion of pre-trained weights, sample video clips, or interactive deployment demos hinders validation of the claimed results.
Lack of Clinical Subgroup Deep-Dive: The dataset features a heavy distribution of Obstructive Sleep Apnea (OSA) patients, yet the clinical implications of these pathological states on staging accuracy are under-explored.
Questions
Baseline Evaluation Fairness & Cross-Dataset Validation: In Appendix C, it is stated that SleepVST was trained on external data (SHHS and MESA), while VINUSS was trained and evaluated within KVSS. To ensure a fair comparison and prove the generalization capability of VINUSS, can the authors provide cross-dataset evaluation results? Specifically, how does VINUSS perform when pre-trained on external video datasets (if available) or tested on an independent cohort?
Rigorous Data Splitting Clarification: Could you explicitly define the exact data splitting mechanism? Was a standard K-fold cross-validation utilized? Furthermore, please explicitly confirm that the train/validation/test sets are strictly subject-independent (i.e., zero overlap of subjects across splits) and temporally disjoint.
Reproducibility and Artifacts: The supplementary material currently lacks model checkpoints, illustrative video frames, or a functional demo. To reinforce the validity of your empirical findings, are you planning to release anonymous pre-trained weights or a web-based inference demo during the discussion phase?
Impact of Obstructive Sleep Apnea (OSA): Given that 43.8% of the KVSS cohort suffers from severe OSA (as shown in Figure A.2), how do these respiratory distress events impact the staging accuracy? It would significantly strengthen the clinical value of this paper if the authors could provide an analysis of whether VINUSS can differentiate or robustly handle abnormal motion profiles caused by OSAS episodes.
Limitations
The authors analyzed standard technical limitations in Section 5. However, they failed to discuss the potential performance degradation of video-native encoders when dealing with atypical pathological sleep patterns (e.g., severe OSA-induced movements vs. normal position changes). Constructive suggestions include providing a error analysis stratified by AHI severity scores.
Final justification
The author's response has largely addressed my concerns. Their cross-dataset validation demonstrates the model's generalizability, and the multiple ablation studies further support the paper's claims. I look forward to the author open-sourcing the demo model to help drive community research.
Formatting concerns
None.
7 comments
Rebuttal
We sincerely appreciate the reviewer's time and the care behind these comments. Several points concern details of our experimental setup that the paper under-described, and we take the opportunity to state them explicitly. We address each point below by providing the requested clarifications and describing the experimental setup for the additional experiments, which are currently underway and whose results will be reported once available.
[W1 / Q1] Potential unfairness in baseline evaluation, and request for cross-dataset validation
(1) Baseline fairness.
We should have described the SleepVST setup more clearly. Its waveform encoder is pre-trained on SHHS and MESA, but the video-derived motion features and the downstream classifier are fitted on the target dataset. Our re-implementation follows this. Optical-flow motion features are extracted from KVSS video, concatenated with the waveform features, and a classifier is trained on KVSS (Appendix C). The baseline does adapt to the target cohort, as the method intends.
Even so, the reviewer is right that the waveform branch itself was never exposed to our data, and that leaves room for doubt. We are therefore fine-tuning the waveform encoder on KVSS as well, so that every component of the baseline sees the target data, and will report the numbers as soon as they are available.
(2) Cross-dataset validation.
Public NIR sleep-video corpora with synchronized PSG labels are not available, so pre-training on external video is not currently possible. External validation is, and we are running it now. KVSS contains two further sites, Hospital B (205 patients) and Hospital C (256 patients), which the dataset paper [1] designates as external test sets and which were never used in training. We evaluate the Hospital A model on both.
Table R1. Acquisition setup at the three KVSS sites. Sample frames from B and C will be added to Appendix A.
| Site | Patients | Camera angle | Distance | Department | Note |
|---|---|---|---|---|---|
| A (training) | 475 | 45° | 3.5 m | otolaryngology | |
| B (external) | 205 | 45° | 3.0 m | neurology | bed oriented diagonally |
| C (external) | 256 | 30° | 3.0 m | otolaryngology |
These are genuinely different acquisition environments rather than a re-split of the same data. The sites were not recorded under a shared protocol, and viewing angle, distance, and bed orientation all differ, which changes the apparent scale and direction of the same thoraco-abdominal displacement and where in the frame it appears. They also draw on different referring departments, so the patient populations differ as well. Each site was also scored by its own technicians, so some label variability across sites is possible [2].
For adaptation we follow the Hospital C split defined in the dataset paper [1] and use a matched design at B, so both sites receive comparable amounts of site-specific data. Adaptation subjects are disjoint from evaluation subjects, and zero-shot results use the same evaluation subjects so the settings compare directly.
We evaluate two settings. The first adapts SDM only, recalibrating full-night structure to the new site without touching the extractor. The second additionally fine-tunes the representation module so the extractor adapts to the new camera geometry. We will report zero-shot alongside both settings during this period. Zero-shot shows whether the model transfers as it stands, and the adaptation settings separate how much of any gap is calibration to the acquisition setup from what does not transfer at all.
[W2 / Q2] Ambiguity in data splitting
We appreciate the chance to make this explicit, as it was under-described, and we will expand Appendix A.1 accordingly.
Subject independence. We can confirm there is no subject overlap between the three sets. This is central to our setup rather than incidental, since as Figure 2(b) shows, epoch embeddings cluster by subject rather than by sleep stage, so any leakage of a subject across splits would let held-out epochs be resolved by subject identity instead of stage inference. Splitting is therefore performed at the subject level before any epoch is materialized, and both training phases use the same partition, with SDM trained on cached features from the same 335 training subjects.
Temporal disjointness. Also confirmed, and in this cohort it follows from subject independence. Each subject contributes exactly one overnight recording, so no night is ever divided between splits and there is no second night from the same patient to leak across. The case where neighbouring epochs from one recording straddle train and test cannot arise.
Cross-validation. We do not use K-fold. We use the fixed 335 / 70 / 70 split defined in the dataset paper [1], which keeps our numbers comparable to other work on the same cohort, and re-splitting would break that comparability. Since this leaves a single split, we characterize uncertainty by subject-level bootstrap over the 70 test subjects (5,000 resamples), giving 95% CIs of [0.784, 0.823] for accuracy and [0.754, 0.797] for macro-F1. Model selection uses the validation subjects only, and the test subjects are untouched until final evaluation.
[W3 / Q3] Insufficient reproducibility support
Sample frames. These are in the paper already. Figure 2(a) shows frame-difference and attention maps on real recordings, and Figures 6 and E.1 show saliency-overlaid NIR frames sampled at 1 Hz across a 30-second epoch, arranged sequentially so the temporal progression is visible. What we cannot do is redistribute the underlying video, since KVSS contains clinical sleep recordings under privacy restrictions and is released only through the controlled-access procedures of the AI Hub portal.
Code and checkpoints. An anonymized implementation is already included with the submission. On acceptance we will release the full training and evaluation code, the preprocessing pipeline (frame extraction, cropping, epoch segmentation), and trained checkpoints for both the representation module and SDM. We are not attaching weights during the discussion phase, since checkpoints trained on this cohort require institutional sign-off that we are pursuing for the public release.
Demo. A hosted inference demo would require users to upload overnight NIR sleep recordings of themselves or of patients, which we do not think appropriate to invite, and we cannot host clinical video ourselves. Our release will instead contain the configurations needed to reproduce our results once KVSS access is granted, and to apply the same pipeline to other NIR sleep cohorts.
[W4 / Q4] Lack of clinical subgroup deep-dive
Appendix D.3 (Fig. D.1) reports per-subject accuracy stratified by AHI group (<5, 5–15, 15–30, >30), which shows no systematic degradation with severity but is subject-level and does not address individual apnea episodes. We are therefore extending the analysis to the event level, comparing epochs that contain scored apnea events against those that do not, and decomposing errors by AHI severity as the reviewer suggests under Limitations. We will report these as soon as they are available and add the resulting discussion to the limitations, which currently does not address pathological motion profiles.
References
[1] Choi et al. Non-contact on-device detection of obstructive sleep apnea from infrared video. Nature Communications, 2026.
[2] Younes et al. Staging sleep in polysomnograms: analysis of inter-scorer variability. JCSM 12(6), 2016.
Thank you to the authors for the detailed explanation of my concerns. I look forward to further discussion once the updated results are available. If the new results successfully address my questions, I will consider raising my score.
Additional results (1/3)
We thank the reviewer for waiting. The experiments we described as underway are now complete, and we report them across the comments below, together with the event-level analysis requested under [W4 / Q4].
[W1 / Q1] Additional results, part 1. Fine-tuning the SleepVST waveform encoder on KVSS
We fine-tuned the waveform encoder on KVSS as suggested, so that every component of the baseline sees the target data. Each variant is fine-tuned on the waveform it is tested on, since we found that fine-tuning on one waveform does not carry over to the other.
Table R2. SleepVST on KVSS before and after fine-tuning the waveform encoder. All rows include the optical-flow motion feature (M). BW* and CW* are contact-sensor waveforms and BW is reconstructed from video. Intervals are subject-level bootstrap 95% CIs.
| Waveform input | Encoder | Acc | κ | MF1 |
|---|---|---|---|---|
| BW* + CW* + M | SHHS + MESA (Table 1) | 0.784 [0.763, 0.802] | 0.635 [0.599, 0.667] | 0.726 [0.698, 0.751] |
| BW* + CW* + M | + fine-tuned on KVSS | 0.799 [0.779, 0.817] | 0.663 [0.628, 0.694] | 0.748 [0.721, 0.772] |
| BW + CW* + M | SHHS + MESA (Table 1) | 0.612 [0.592, 0.631] | 0.236 [0.208, 0.266] | 0.371 [0.344, 0.400] |
| BW + CW* + M | + fine-tuned on KVSS | 0.674 [0.648, 0.700] | 0.422 [0.375, 0.470] | 0.571 [0.533, 0.610] |
| Video only | ViNUSS | 0.804 [0.784, 0.823] | 0.684 [0.650, 0.713] | 0.777 [0.754, 0.797] |
Fine-tuning helps the baseline in both conditions, by 0.022 MF1 with the contact-sensor waveform and by 0.200 with the reconstructed one. The reviewer's concern was well placed, and the stronger baseline is the one we should be compared against.
With contact-sensor waveforms the fine-tuned baseline reaches 0.748 [0.721, 0.772] against 0.777 [0.754, 0.797] for video-only ViNUSS, and the intervals overlap substantially. We do not claim a reliable advantage over the baseline in that configuration. What it shows is that staging from face-anonymized video alone is on par with a proxy pipeline that has been given clean contact measurements of both breathing and cardiac activity and adapted to our cohort.
That configuration is not available without an effort belt. In the configuration that a contactless system could actually run, with the breathing waveform reconstructed from video, the strongest baseline we could construct reaches 0.571 [0.533, 0.610] against 0.777, with no overlap on any metric. This is the comparison the paper's claim rests on, and we will report both conditions in the revision so the baseline is represented at its strongest.
The cross-dataset validation results follow in the next comment.
- Rating
- 4/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper presents VINUSS, a video-only framework for non-contact sleep staging using near-infrared (NIR) video. To avoid the vulnerabilities of traditional methods that rely on explicit physiological proxy reconstruction (e.g., rPPG or breathing waveforms), the authors propose a pipeline comprising a Pixel-Wise Temporal Encoder (PTE) for capturing local micro-motions, an Intra-Subject Discriminability Loss (ISDL) to mitigate subject-specific biases, and a two-scale Mamba architecture for temporal sequence modeling across the full night. Evaluated on the large-scale KVSS dataset, the method demonstrates strong performance in four-class sleep staging and provides promising interpretability via spatiotemporal saliency maps.
Strengths and weaknesses
Strengths
-
Strong Originality: The paradigm of "video-only" sleep staging without auxiliary physiological proxy supervision or cross-modal distillation is refreshing and highly practical for real-world deployments.
-
Well-Designed Architecture: The combination of pixel-level micro-motion capturing (PTE) and state-space sequence modeling (Mamba) effectively tackles both local transient movements and global full-night sleep continuity.
-
Solid Empirical Results: Demonstrating high accuracy (0.80) and macro-F1 (0.78) on a massive dataset of 475 clinical overnight recordings proves the efficacy of the framework.
Weaknesses
-
Limited Evaluation Scope: While the clinical cohort is large, the evaluation is strictly intra-dataset (within KVSS). The model's robustness against domain shifts remains unverified.
-
Ambiguity in Optical and Sampling Configurations: Crucial physical parameters regarding the NIR imaging system and the justification for using a low frame rate (5 FPS) are missing, which raises questions about the extraction limits of high-frequency physiological phenomena.
-
Lack of Error and Failure Mode Analysis: The paper showcases strong statistical improvements but lacks a deep dive into typical failure cases or a characterization of data segments where the model underperforms.
Questions
Cross-Dataset Generalization: The current experimental analysis is entirely restricted to the KVSS dataset. To further demonstrate the robustness and real-world applicability of VINUSS, have the authors considered validating the pre-trained framework on an independent external dataset? Even a zero-shot or light fine-tuning evaluation on another video cohort would greatly strengthen the paper.
Open-Source Commitment and Community Impact: The proposed framework could serve as a solid baseline for the contactless health monitoring community. Do the authors intend to publicly release the complete source code, preprocessing scripts, and trained model checkpoints upon acceptance to facilitate reproducibility and long-term community development?
Failure Mode and Vulnerability Analysis: To better understand the boundaries of the proposed model, under what specific conditions or sample cohorts does the model's performance degrade? For instance, does the performance drop significantly during heavy bedding occlusion, specific sleeping postures (e.g., prone vs. supine), or in patients with extremely low baseline respiratory amplitudes?
NIR Optical Specifications & Low Sampling Rate Constraints:
(a) Could the authors specify the exact wavelength band (e.g., 850nm or 940nm) used for the NIR camera system? This physical detail is important for understanding the visual contrast of micro-motions.
(b) The video is sampled at a relatively low rate of 5 FPS. While sufficient for macro-movements, a low sampling rate can introduce aliasing or severely limit the extraction of higher-frequency periodic signals (e.g., micro-arousal tremors or subtle cardiac proxies if relevant). How does the architecture inherently mitigate the information loss caused by this low temporal resolution?
Limitations
The authors conclude with a standard discussion on data scaling. However, the limitation section would be more comprehensive if it explicitly addressed how the low frame rate (5 FPS) restricts the model from capturing faster physiological changes, and how different camera placement angles might affect the pixel-wise temporal encoder.
Final justification
The author addressed most of my concerns. I would vote for accepatance.
Formatting concerns
N/A
7 comments
Rebuttal
We are grateful for the reviewer's careful reading and constructive comments. We address each weakness and question below, with the requested clarifications and the design of the further experiments now underway, whose results we will report as they become available.
[W1 / Q1] Limited evaluation scope, and request for cross-dataset generalization
We are running external validation now. KVSS contains two further sites, Hospital B (205 patients) and Hospital C (256 patients), which the dataset paper [1] designates as external test sets and which were never used in training. We evaluate the Hospital A model on both, following the same external-validation protocol.
Table R1. Acquisition setup at the three KVSS sites. Sample frames from B and C will be added to Appendix A.
| Site | Patients | Camera angle | Distance | Department | Note |
|---|---|---|---|---|---|
| A (training) | 475 | 45° | 3.5 m | otolaryngology | |
| B (external) | 205 | 45° | 3.0 m | neurology | bed oriented diagonally |
| C (external) | 256 | 30° | 3.0 m | otolaryngology |
These are genuinely different acquisition environments rather than a re-split of the same data. The sites were not recorded under a shared protocol, and viewing angle, distance, and bed orientation all differ, which changes the apparent scale and direction of the same thoraco-abdominal displacement and where in the frame it appears. They also draw on different referring departments, so the patient populations differ as well. Each site was also scored by its own technicians, so some label variability across sites is possible [2].
For adaptation we follow the Hospital C split defined in the dataset paper [1] and use a matched design at B, so both sites receive comparable amounts of site-specific data. Adaptation subjects are disjoint from evaluation subjects, and zero-shot results use the same evaluation subjects so the settings compare directly.
We evaluate two settings. The first adapts SDM only, recalibrating full-night structure to the new site without touching the extractor. The second additionally fine-tunes the representation module so the extractor adapts to the new camera geometry. Following the reviewer's suggestion that even zero-shot or light fine-tuning would strengthen the paper, we will report zero-shot alongside both settings during this period. This also gives us measurements for the camera-placement point raised under Limitations, since PTE preserves where each temporal response occurred and is therefore tied to imaging geometry. We will ground that discussion in these results rather than stating it as a general caveat.
[W2 / Q4] Ambiguity in optical and sampling configurations
We agree that these parameters belong in the paper and will add both.
(a) Wavelength.
KVSS was assembled retrospectively from cameras already installed as clinical infrastructure [1]. Recordings at each hospital span several sleep laboratories, each with its own camera, and Hospital A alone covers multiple rooms and two manufacturers. The illumination band is not documented in the installation records. These are wall-mounted IR surveillance-class cameras, so the recordings fall in the standard 850–940 nm NIR regime. Our Hospital A results therefore already span multiple optical configurations.
(b) Sampling rate.
5 fps is not a choice on our part. All sites were standardized to 640 × 480 at 5 fps when the dataset was constructed [1], and that is the form in which the data is available.
Respiration is far from aliasing. The Nyquist limit at 5 fps is 2.5 Hz, while thoraco-abdominal periodicity sits at 0.17–0.30 Hz, roughly 8–15× below it, and Figure 1(a-b) shows pixel-wise FFT resolving these responses cleanly against contact thoracic spectra.
Body movement is slower than the frame interval. Movements scored in PSG have minimum durations of around half a second, and postural shifts are slower still, so they span several frames at 0.2 s resolution and register as inter-frame change, and SVECAM confirms the model attends to them (Fig. 6b). What 5 fps cannot capture is motion beginning and ending within one frame interval, or the spectral structure of fast oscillatory motion such as tremor. Cardiac signals are outside our scope, since we reconstruct no cardiac waveform and face blurring rules out rPPG regardless of frame rate (§4.2).
Each epoch still yields 150 frames, and PTE scans all of them with short temporal kernels before any spatial aggregation, so temporal variation is encoded per pixel rather than diluted. The effective receptive fields of 1.8 s and 2.6 s (Appendix B.1.1) are matched to sub-epoch motion, and SDM accumulates evidence across the night.
We will state the optical setup in Appendix A and the frame-rate constraint in the limitations.
[W3 / Q3] Lack of error and failure mode analysis
We separate two questions: what kind of errors the model makes, and under what conditions they concentrate. The first is complete and reported here, and the second is running.
(1) About half of the errors are timing offsets rather than stage confusions.
Table R2. Four-class performance under increasing temporal tolerance between prediction and label.
| Tolerance | Acc | MF1 |
|---|---|---|
| exact | 0.804 | 0.777 |
| ±1 epoch | 0.859 | 0.828 |
| ±3 epochs | 0.898 | 0.869 |
Allowing the label to shift by up to three epochs recovers 47% of all errors. Appendix D.5 noted qualitatively that errors cluster near stage boundaries, and this quantifies it. The model identifies each region's sleep depth but leads or lags the boundary by a few epochs. Of the errors that remain, adjacent-depth confusions dominate, with Light↔Deep the most frequent pair.
(2) Where errors concentrate (in progress).
We are extending the analysis to the conditions under which errors concentrate, covering the three axes the reviewer names.
For bedding occlusion, KVSS annotates three levels (none, partial, full) for all 70 test subjects, and we compare per-subject macro-F1 and κ across them with an ordered-trend test.
For sleep position, PSG position annotations let us stratify epoch-level error by supine against non-supine, per stage.
For baseline respiratory amplitude, we characterize each subject's contact thoracic and abdominal effort signal and relate it to per-subject and per-stage error. Beyond raw amplitude we also examine how stable the signal is, since a subject can have strong but irregular respiration, and we expect this to bear on the Light↔Deep confusion above.
We are additionally checking OSA severity strata and a movement-heavy clinical subgroup, where limb movement could plausibly be mistaken for arousal-related motion. All comparisons use subject-level bootstrap CIs over the 70 test subjects on the frozen checkpoint.
We will report these during this period and incorporate them into the discussion.
[Q2] Open-source commitment and community impact
An anonymized implementation is already included with the submission, and upon acceptance we will publicly release the full training and evaluation code, the preprocessing pipeline (frame extraction, cropping, epoch segmentation, HDF5 packing), and the trained checkpoints for both the representation and sleep dynamics modules. KVSS itself is available only through the controlled-access procedures of the AI Hub portal, so the release will include the configurations needed to reproduce our results once access is granted, and to apply the same pipeline to other NIR sleep cohorts.
References
[1] Choi et al. Non-contact on-device detection of obstructive sleep apnea from infrared video. Nature Communications, 2026.
[2] Younes et al. Staging sleep in polysomnograms: analysis of inter-scorer variability. JCSM 12(6), 2016.
Thanks for the rebuttal
Thanks for the authors to provide a detailed rebuttal. It addressed most of my concerns expect the "Where errors concentrate". However, I am satisfied with the current results and analysis. I believe that a bit more analysis into the errors would make the paper more interesting and inspiring.
Additional results (1-1/2)
We thank the reviewer for the follow-up comment. Both experiments we described as underway are now complete. These comments cover the cross-site evaluation for [W1 / Q1], and the error-concentration analysis for [W3 / Q3] follows.
[W1/Q1] Additional results: cross-site evaluation
Following the reviewer's suggestion that zero-shot or light fine-tuning at another site would strengthen the paper, we evaluated the Hospital A model on Hospitals B and C in all three settings. Site differences are summarized in Table R1 of our rebuttal. Adaptation subjects are disjoint from evaluation subjects, and all settings are evaluated on the same subjects per site.
Table R3. Cross-site performance. n is the number of test subjects at each site, disjoint from the train subjects used for adaptation. Intervals are subject-level bootstrap 95% CIs.
| Site | Adaptation | # of Train Subjects | Acc | κ | MF1 |
|---|---|---|---|---|---|
| B (n=60) | none | 0 | 0.606 [0.560, 0.650] | 0.291 [0.238, 0.347] | 0.463 [0.418, 0.506] |
| B | SDM only | 30 | 0.763 [0.737, 0.786] | 0.545 [0.503, 0.583] | 0.615 [0.576, 0.650] |
| B | SDM only | 75 | 0.774 [0.747, 0.801] | 0.535 [0.489, 0.579] | 0.624 [0.579, 0.661] |
| B | both modules | 30 | 0.786 [0.759, 0.813] | 0.549 [0.499, 0.598] | 0.627 [0.574, 0.674] |
| B | both modules | 75 | 0.800 [0.774, 0.824] | 0.587 [0.542, 0.630] | 0.637 [0.588, 0.679] |
| C (n=110) | none | 0 | 0.634 [0.616, 0.651] | 0.319 [0.285, 0.352] | 0.478 [0.442, 0.510] |
| C | SDM only | 30 | 0.712 [0.694, 0.731] | 0.498 [0.466, 0.530] | 0.612 [0.578, 0.644] |
| C | SDM only | 76 | 0.700 [0.683, 0.716] | 0.494 [0.466, 0.521] | 0.598 [0.569, 0.624] |
| C | both modules | 30 | 0.714 [0.697, 0.729] | 0.502 [0.476, 0.528] | 0.598 [0.570, 0.623] |
| C | both modules | 76 | 0.745 [0.730, 0.759] | 0.566 [0.541, 0.590] | 0.648 [0.616, 0.675] |
Without adaptation performance drops at both sites, and the drop takes a specific form. Each site collapses toward a different stage. At B, Light and REM epochs are absorbed into Wake, which is predicted about twice as often as it occurs, while at C the opposite happens and about half of the true Wake epochs are labelled Light. This points to the stage boundaries sitting at the wrong operating point rather than to epoch-level evidence being absent from the recordings.
Light fine-tuning is consistent with that reading. Recalibrating SDM alone, without touching the representation module, already reaches 0.624 MF1 at B and 0.612 at C, and the errors above move back in the process, with the Light-to-Wake leakage at B falling from 23.7% to 5.0% and Wake recall at C rising from 42.5% to 70.4%.
Adapting the representation module as well reaches 0.637 and 0.648. The two settings address different parts of the shift. Recalibrating the boundaries realigns the model to the local stage distribution, while adapting the extractor absorbs the change in apparent scale and direction of thoraco-abdominal motion that follows from a different camera and viewpoint. The latter is larger at C, adding 0.036 against 0.013 at B, consistent with C being the site whose camera angle differs from Hospital A while B shares it. We will discuss camera placement in the limitations with reference to these results rather than as a general caveat.
Adaptation is also data-efficient. With 30 subjects, adapting both modules already reaches 0.786 accuracy at B, close to the 75-subject row, and 0.714 at C, where more data continues to help. MF1 and κ remain below Hospital A in every setting, so we look at where that residual sits stage by stage in the next comment.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Summary of the discussion period
We thank the AC for the Meta Review. We are grateful that it captures both what the reviewers found valuable in the work and what needed to be shown, and the four points it lists gave us a clear agenda for the discussion period. We also thank the reviewers for feedback that was constructive throughout, and we believe the additional experiments and analyses conducted in response have made the paper more solid.
The first two points, the proxy-input experiment and the variance estimates, were raised by Reviewer uFaX. We ran the requested proxy-fusion ablation, which shows no measurable benefit from adding waveform proxies to the video representation, and applied subject-level bootstrap CIs to every result including all baselines. The reviewer has since confirmed the primary concern addressed and moved the rating into the accept range.
The split description and the stratified appendix were both already in the paper but not signposted from the main text. During the discussion we confirmed subject independence and temporal disjointness, and extended the AHI-stratified analysis in Appendix D.3 to individual respiratory events and to severity groups. We will add explicit pointers along with the expanded content.
On the baseline comparison and the other details raised in the reviews, we fine-tuned the SleepVST waveform encoder on KVSS so that every component sees the target data, and report against that stronger baseline. On reproducibility, an anonymized implementation is already included with the submission, and we detailed what will be released on acceptance and why checkpoints and a hosted demo cannot be attached during discussion. We also specified the optical setup and the frame-rate constraint, both of which we will add to the paper.
Evaluation beyond the single cohort was raised by all three reviewers. We ran the cross-site evaluation on two held-out KVSS sites zero-shot and under two adaptation settings, together with the analyses each reviewer requested on failure modes, respiratory events, and disease severity. Reviewers KeGQ and 4pmZ indicated they would reassess once these results were available, and we have reported each of them in full in their threads.
Every result and analysis reported during the discussion will be added to the paper, together with the limitations they make explicit. We thank the AC and the reviewers for the time and care they have given this submission.