potentialpaper

ParaPC-FM: Accelerating Parallel Sampling via Principled Initialization

Bangwei Li, Chuan Gou, Jianrong Lu, Guoyao Yu, Jianhai Chen

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. We introduce ParaPC-FM, a parallel sampling framework for flow matching models that combines fixed-point iterations with solver-level and initialization refinements, leading to faster parallel inference in practice.

Abstract. Flow matching and diffusion models achieve high-quality generation by solving continuous-time generative dynamics, but their sampling remains inherently sequential and costly. Parallel sampling reduces wall-clock latency, yet often requires many function evaluations (NFEs) due to inaccurate future-state initialization and repeated correction. We propose ParaPC-FM, a fixed-point predictor–corrector framework that unifies high-order solver correction and future-state initialization, enabling both components to be incorporated into different parallel samplers. In particular, our UniP-based truncated initialization reuses past velocity predictions to estimate future states more accurately, reducing correction iterations and NFEs. Initialization requires no additional model evaluations and incurs negligible arithmetic overhead relative to a model forward pass. On a ParaDiGMS-style framework, ParaPC-FM achieves up to 1.25×1.25\times and 1.49×1.49\times speedups on FLUX.1-dev at 5050 and 100100 steps, and up to 1.22×1.22\times and 1.16×1.16\times speedups on Stable Diffusion 3 and Stable Diffusion 3.5 at 5050 steps. When integrated into ParaTAA, the proposed initialization further achieves up to 1.17×1.17\times speedup at 5050 steps. Under matched-tolerance comparisons, ParaPC-FM improves latency with comparable reported reference-fidelity and preference metrics. Code is available at https://github.com/libangwei01/ParaPC-FM.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
4 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 4 reviews · OpenReview

Updated 25 Nov 2026, 03:48 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

This work aims to reduce correction rounds in parallel-in-time sampling. ParaPC-FM adapts UniPC-style predictor–corrector ideas to improve future-state initialization and parallel updates, reporting moderate wall-clock gains on FLUX.1-dev, SD3, SD3.5, and ParaTAA.

The main strengths are the clear numerical formulation, negligible initialization overhead, evaluation across several modern models, and transfer to another parallel sampler.

This work has several major concerns. (1). Most experiments use 50 or 100 sampling steps on eight accelerators, whereas strong sequential solvers commonly target much lower NFE regimes. The method also benefits more as the trajectory becomes longer. The claims of the paper therefore require matched-quality and matched-wall-clock comparisons against strong 10–20-NFE sequential samplers, along with total accelerator cost rather than latency alone. (2). Since q=1 is usually best and q=2 can hurt, it is unclear whether the gains require the proposed UniPC-inspired construction or mainly come from simple first-order extrapolation. Comparisons with Euler, linear, or Adams–Bashforth initialization, and with the original ParaDiGMS under matched settings, are needed. (3). CLIP and ImageReward are nearly constant, while RMSE can reach 0.10–0.14, and some qualitative outputs differ noticeably from the sequential reference. A speed–quality Pareto curve using a more sensitive metric or human preference evaluation would strengthen the evidence.

This submission is technically sensible and potentially useful, but its practical advantage over modern low-NFE sequential sampling is not yet established. Convincing matched comparisons in the 10–20-step regime, clearer isolation of the initialization contribution, and stronger quality evaluation would substantially strengthen the paper.

Final justification

The rebuttal addressed the main concerns with new low-NFE comparisons, initialization baselines, and improved fidelity analysis. While the contribution is incremental, it provides consistent latency gains across several models and parallel samplers with little degradation in the reported metrics.

Area Chair ZZ54 · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

This work aims to reduce correction rounds in parallel-in-time sampling. ParaPC-FM adapts UniPC-style predictor–corrector ideas to improve future-state initialization and parallel updates, reporting moderate wall-clock gains on FLUX.1-dev, SD3, SD3.5, and ParaTAA.

The main strengths are the clear numerical formulation, negligible initialization overhead, evaluation across several modern models, and transfer to another parallel sampler.

This work has several major concerns. (1). Most experiments use 50 or 100 sampling steps on eight accelerators, whereas strong sequential solvers commonly target much lower NFE regimes. The method also benefits more as the trajectory becomes longer. The claims of the paper therefore require matched-quality and matched-wall-clock comparisons against strong 10–20-NFE sequential samplers, along with total accelerator cost rather than latency alone. (2). Since q=1 is usually best and q=2 can hurt, it is unclear whether the gains require the proposed UniPC-inspired construction or mainly come from simple first-order extrapolation. Comparisons with Euler, linear, or Adams–Bashforth initialization, and with the original ParaDiGMS under matched settings, are needed. (3). CLIP and ImageReward are nearly constant, while RMSE can reach 0.10–0.14, and some qualitative outputs differ noticeably from the sequential reference. A speed–quality Pareto curve using a more sensitive metric or human preference evaluation would strengthen the evidence.

This submission is technically sensible and potentially useful, but its practical advantage over modern low-NFE sequential sampling is not yet established. Convincing matched comparisons in the 10–20-step regime, clearer isolation of the initialization contribution, and stronger quality evaluation would substantially strengthen the paper.

Final justification

The rebuttal addressed the main concerns with new low-NFE comparisons, initialization baselines, and improved fidelity analysis. While the contribution is incremental, it provides consistent latency gains across several models and parallel samplers with little degradation in the reported metrics.

1 comment
Authors · CommentOpenReview ↗

We sincerely thank the Area Chair for the careful synthesis of the reviews, and all reviewers for the time and thoughtful feedback devoted to our work. The questions concerning low-NFE practicality, isolation of the initialization contribution, and quality evaluation help us clarify both the evidence and the intended scope of ParaPC-FM. We address them below and will revise our claims accordingly.

Q1: Low-NFE sequential comparison

We added a 15-step comparison with sequential UniPC-2 under the same evaluation setting. UniPC-2 uses one NPU; the parallel methods use eight.

Method Rounds ↓\downarrow Time (s) ↓\downarrow Est. NFE* ↓\downarrow IR ↑\uparrow CLIP ↑\uparrow Speedup ↑\uparrow
UniPC-2 (1 NPU) 15.000 7.580 15.000 0.772 26.0 1.00×1.00\times
p=0,q=0p=0,q=0 5.704 2.248 45.632 0.738 25.6 3.37×3.37\times
p=0,q=1p=0,q=1 5.688 2.243 45.504 0.736 25.6 3.38×3.38\times
p=0,q=2p=0,q=2 5.846 2.266 46.768 0.740 25.6 3.34×3.34\times
p=1,q=0p=1,q=0 6.088 2.349 48.704 0.764 25.9 3.23×3.23\times
p=1,q=1p=1,q=1 6.041 2.340 48.328 0.764 25.9 3.24×3.24\times
p=1,q=2p=1,q=2 6.230 2.359 49.840 0.765 25.9 3.21×3.21\times
p=2,q=0p=2,q=0 6.529 2.526 52.232 0.772 26.0 3.00×3.00\times
p=2,q=1p=2,q=1 6.501 2.523 52.008 0.772 26.0 3.00×3.00\times
p=2,q=2p=2,q=2 6.596 2.537 52.768 0.774 26.0 2.99×2.99\times

*For parallel runs, NFE^=8×\widehat{\mathrm{NFE}}=8\times effective rounds is a conservative coarse estimate. It counts boundary/tail windows with fewer than eight active states as full eight-state windows, so actual NFE is slightly lower; all configurations use the same convention.

At matched reported quality, p=2,q=1p=2,q=1 preserves both IR (0.772) and CLIP (26.0) while reducing latency from 7.580 s to 2.523 s (3.00×3.00\times). This is a latency gain through hardware parallelism, not a compute saving: its estimated NFE is 52.008 and its accelerator time is 20.185 NPU-s, versus 15 NFE and 7.580 NPU-s for UniPC-2. The q=1q=1 gain over q=0q=0 is also marginal at 15 steps. We will therefore position ParaPC-FM as a training-free latency method for moderate/long trajectories, especially when retraining or distillation is unavailable, rather than as a replacement for strong few-step solvers.

Q2: Initialization contribution

In our notation, p=0,q=0p=0,q=0 exactly recovers original ParaDiGMS, while q=1q=1 is a first-order Euler predictor. We also added two simpler FLUX.1-dev 50-step baselines (n=8n=8):

Method Rounds ↓\downarrow Time (s) ↓\downarrow IR ↑\uparrow CLIP ↑\uparrow
ParaDiGMS / q=0q=0 15.243 6.385 0.846 26.1
ParaPC-FM / q=1q=1 13.282 5.581 0.845 26.1
Finite-difference extrapolation 14.954 6.296 0.846 26.1
Least-squares extrapolation 14.552 6.115 0.842 26.0

The proposed initialization is faster at comparable quality. The least-squares baseline additionally requires offline calibration on disjoint trajectories, whereas ours uses only cached boundary velocities and adds no model evaluations. We will explicitly label q=0q=0 as original ParaDiGMS and describe higher-order qq as related to classical multistep extrapolation.

Q3: Quality evaluation

Table 1 RMSE uses the corresponding 100-step sequential solver as reference; hence 25/50-step RMSE contains both discretization error and parallel early-stopping error. It is not a percentage of perceptual degradation. Within each fixed model, step budget, and pp, all qq share the same tolerance, and their RMSE differs by at most 0.001 whenever possible.

We additionally computed 25/50-step RMSE against same-step sequential references, separating parallel error from the 100-step discretization gap, and supplemented IR results on FLUX, SD3, and SD3.5. These metrics remain closely matched across qq. Our complete response to this concern, including all numerical results, is provided in our response to Reviewer 5Dzf. ImageReward is a learned human-preference metric, not a human study. Preliminary FID was unreliable with only 1,000 samples and a mismatched MS-COCO reference, sometimes ranking visibly worse SD outputs above FLUX; we therefore do not use it as evidence. We will instead add a speedup-versus-reference-fidelity Pareto curve from the tolerance sweep and replace “quality nearly unchanged” with a claim explicitly conditioned on the reported metrics and tolerance.

We sincerely thank the Area Chair and all reviewers again for their careful consideration and constructive feedback. We hope these additions clarify both the evidence and the scope of our claims. We welcome further comments and look forward to continued exchange and discussion.

Reviewer C9hFOpenReview ↗
Rating
5/6
Confidence
2/5
Quality
3/4
Clarity
4/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper studies parallel-in-time sampling for flow-matching image generation models, aiming to reduce the wall-clock cost of iterative sampling. Instead of generating states strictly one after another, the method maintains a window of future sampling states, evaluates model velocities for them in parallel, and iteratively refines the states until a converged prefix can be accepted and the window slides forward.

Its main contribution is a unified predictor-corrector-style parallel sampling framework that combines two components: a high-order correction rule for updating future states, and a future-state initialization rule for producing better starting guesses. These two components are controlled separately by the correction order p and initialization order q, allowing the method to flexibly trade off correction accuracy and initialization quality.

A distinctive part of the method is the proposed truncated initialization. Given the last reliable state, it initializes future states by reusing past velocity predictions, in a UniPC-inspired multistep extrapolation manner. This provides more accurate initial guesses for future states without requiring additional model evaluations.

The method is designed as an inference-only acceleration technique. It does not require changing the model architecture or retraining the flow-matching model, and can be incorporated into existing parallel sampling pipelines. Empirically, the paper reports that better future-state initialization improves the convergence speed of parallel sampling and leads to faster image generation while maintaining sample quality.

Strengths and weaknesses

Strengths

The paper addresses a well-motivated technical problem: reducing the wall-clock cost of sampling in flow-matching/image generation models by parallelizing across time. The proposed method is technically sensible, combining windowed parallel fixed-point inference with higher-order correction and future-state initialization. A particularly useful aspect is the separation between the solver update order (p) and the initialization order (q), which allows the authors to study correction quality and initialization quality as distinct factors. The method is also attractive because it is inference-only and does not require modifying the model architecture or retraining.

Efficient sampling remains an important bottleneck for diffusion and flow-matching generative models. A method that improves parallel sampling convergence without extra training or model changes is potentially useful for both researchers and practitioners.

Weaknesses

Quality. While the method is technically plausible, some claims would benefit from stronger isolation of the contributing factors. In particular, if the results show that (q=1) is often the best or most stable initialization setting while higher-order (q=2) can be worse, then the improvement may come mainly from using a simple nontrivial extrapolation rather than from the specific UniPC-style truncated initialization. This makes it important to compare against simpler initialization baselines, such as Euler extrapolation, linear extrapolation, Adams-Bashforth-style predictors, or ParaDiGMS equipped with similar initialization strategies. Without these comparisons, it is harder to determine whether the proposed initialization design itself is responsible for the gains.

Originality. The general framework of maintaining a future-state window, evaluating model predictions in parallel, performing fixed-point/Picard-style refinement, accepting a converged prefix, and sliding the window forward is closely related to ParaDiGMS-style parallel sampling. The higher-order correction and initialization are useful, but they are also related to known multistep extrapolation and predictor-corrector ideas. Therefore, the work is best viewed as a valuable numerical refinement and adaptation of existing ideas to flow-matching parallel sampling, rather than a fundamentally new parallel sampling paradigm.

Questions

Q1. Can the authors better isolate the contribution of the proposed truncated initialization from simpler extrapolation baselines? Since q=1 appears to be strong or more stable in some settings, it would be useful to compare against simple Euler, linear extrapolation, Adams-Bashforth-style predictors, or ParaDiGMS with comparable initialization.

Q2. How sensitive is the method to window size?

Q3. How much improvement does the proposed method provide over the original ParaDiGMS under matched settings? The current results seem to quantify improvement mainly over the paper’s own no-initialization baseline, rather than clearly separating gains over the original ParaDiGMS framework.

Limitations

yes

Final justification

Having considered other reviewers' comments and the authors' responses, I think "ParaPC-FM is a principled, inference-only numerical refinement of ParaDiGMS" accurately summaries the main idea of this paper. The idea is sensible. The reported acceleration is meaningful. Therefore, I am upgrading my overall score to 5 (accept).

Formatting concerns

No major issue.

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely thank the reviewer for the careful and thoughtful reading of our paper and for the constructive suggestions. We particularly appreciate the questions concerning the isolation of the initialization contribution, sensitivity to window size, and the matched comparison with the original ParaDiGMS. These comments have helped us identify important aspects of the presentation and evaluation that should be made clearer. We agree that the paper should more explicitly separate the contribution of the initialization module from the underlying parallel-sampling framework. We will revise the positioning accordingly: ParaPC-FM is a principled, inference-only numerical refinement of ParaDiGMS, rather than a fundamentally new parallel-sampling paradigm.

Q1: Isolation from simple extrapolation baselines

We apologize that the baselines were not sufficiently explicit. In our notation, p=0,q=0p=0,q=0 is exactly the original ParaDiGMS method: Euler correction with the original no-special-initialization rule. Moreover, q=1q=1 is itself the simple first-order Euler predictor requested by the reviewer. Thus, comparing p=0,q=1p=0,q=1 with p=0,q=0p=0,q=0 isolates the benefit of nontrivial future-state initialization under the same model, time grid, tolerance, seeds, hardware, and parallel framework.

To further test whether the benefit is specific to our truncated initialization, we added two simple alternatives on FLUX.1-dev at 50 steps (window size n=8n=8). Finite-difference velocity extrapolation estimates a local acceleration from the last two available velocities and linearly extrapolates future velocities. Least-squares velocity extrapolation fits, at each time step, a linear combination of the last two velocities using trajectories generated from a separate set of 1,000 prompts; the fitting trajectories are disjoint from evaluation prompts. Neither method adds model evaluations at inference; the latter, unlike our method, requires offline calibration.

Method Effective rounds ↓\downarrow Time (s) ↓\downarrow ImageReward ↑\uparrow CLIP ↑\uparrow
Sequential 50.000 22.788 0.842 26.0
ParaDiGMS / p=0,q=0p=0,q=0 15.243 6.385 0.846 26.1
ParaPC-FM / p=0,q=1p=0,q=1 13.282 5.581 0.845 26.1
Finite-difference velocity extrapolation 14.954 6.296 0.846 26.1
Least-squares velocity extrapolation 14.552 6.115 0.842 26.0

The proposed initialization is faster than both alternatives while maintaining comparable ImageReward and CLIP. In particular, the least-squares predictor uses extra offline trajectory data yet remains slower than the parameter-free q=1q=1 initializer. We will add these comparisons and clarify that higher-order qq is related to classical multistep extrapolation; our contribution is a moment-matched truncated construction that uses only the velocities available at the sliding-window boundary, requires neither extra model evaluations nor offline fitting, and plugs into parallel samplers.

Q2: Sensitivity to window size

We agree that window size is important. The submission fixed n=8n=8 because the main experiments use eight NPUs, but did not report sensitivity. We now evaluate the same ParaPC-FM configuration (p=0,q=1p=0,q=1) with different window sizes:

Method Window Effective rounds ↓\downarrow Time (s) ↓\downarrow ImageReward ↑\uparrow CLIP ↑\uparrow
Sequential 1 50.000 22.788 0.842 26.0
ParaPC-FM 4 22.439 9.586 0.845 26.1
ParaPC-FM 8 13.282 5.581 0.845 26.1
ParaPC-FM 16 12.757 10.199 0.851 26.2

Initialization maintains comparable quality across window sizes. Increasing the window reduces correction rounds, but wall-clock time is not monotonic: n=4n=4 underutilizes the eight devices, whereas n=16n=16 exceeds available parallelism and requires additional scheduling/batches. Consequently, n=8n=8, which matches the hardware parallelism, gives the best end-to-end time. We will report this trade-off and state that window size should be selected jointly with available device parallelism.

Q3: Improvement over original ParaDiGMS

Thank you for highlighting this ambiguity. We will replace the imprecise phrase “ParaDiGMS-style” with an explicit statement that p=0,q=0p=0,q=0 recovers the original ParaDiGMS method. Therefore, the first two non-sequential rows above give the matched comparison requested in Q3: adding our q=1q=1 initialization to ParaDiGMS reduces effective rounds from 15.243 to 13.282 and time from 6.385s to 5.581s (1.14×1.14\times speedup), with comparable ImageReward (0.846 vs. 0.845) and CLIP (26.1 for both). The corresponding 100-step result in Table 1 reduces time from 14.409s to 11.948s (1.21×1.21\times), with RMSE 0.034 versus 0.035. We will label p=0,q=0p=0,q=0 as “ParaDiGMS (original baseline)” throughout the revision and report speedups relative to it directly.

We sincerely thank the reviewer again for these valuable and constructive comments. These clarifications and added experiments more directly establish the scope of the contribution: a nearly free truncated initialization module that improves the speed--fidelity trade-off of ParaDiGMS and other parallel samplers. We would greatly appreciate any further suggestions from the reviewer and would be very happy to continue the discussion or provide additional clarification.

Reviewer C9hF · CommentOpenReview ↗

Thank you. I have read your responses. The clarification and the added experiments answered my questions.

Authors · CommentOpenReview ↗

We are very pleased that our response has fully addressed your concerns. We sincerely thank you for raising the score from 3 to 5 (accept)—this is greatly encouraging to us.

Reviewer cG6aOpenReview ↗
Rating
5/6
Confidence
2/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

Diffusion is sped-up by evolving many (e.g. 8) timesteps in parallel rather than sequential sampling. The authors present a method to initialized future steps, and evolve them in parallel leading to an overall speed up in processing even though more operations are used. They improve over past parallel methods by initializing future states using higher order predictions (mixing the vectors from previous as well as the current timestep), so that fewer parallel updates are needed. The method works with other approaches to acheive a speed-up.

Strengths and weaknesses

The method makes sense, is easy enough to understand in context, is evaluated in tables to show numerical improvements, and shown qualitatively. I would think that speedups of 17-49% are enough to matter. I found the descrption clear and sensible, the idea sensible.

The weeknesses are that the tables (e.g. Table 1 and Table 2) do not include a speedup column, making it hard to confirm the claims in the abstract/intro. Furthermore, the qualiatative examples (ex. Fig 7, Fig 8) are significantly different than the sequential output.

Questions

The improvement (quality, speed) wrt bare ParaDGM are not obvious. ParaTAA is clear from Table 4. I think Table 1 has the comparison but it is not clear. So the question would be -- how toes your method improve of ParaDGM (as same as possible w/o your initialization vs with)

Why are Fig 7 and Fig 8 so different from sequential? Are they lemon-picked? Does CLIP or MSE not flag the difference?

Did you evaluate the NFEs?

Limitations

Yes.

Final justification

Thank you for addressing my presentation concerns, bumped to 5.

Formatting concerns

Some figures are packed awkwardly. Esp. fig 5.

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely thank the reviewer for the careful reading and constructive feedback. We especially appreciate the reviewer’s recognition that the method is sensible and clearly presented, and that the reported acceleration is practically meaningful. The questions also identify three places where our current presentation is insufficiently explicit. We agree that the paper should (i) show the improvement over the original ParaDiGMS baseline directly, (ii) explain the purpose of the deliberately selected qualitative examples, and (iii) clarify how the reported Steps correspond to NFEs.

Q1: Direct comparison with the original ParaDiGMS baseline

We apologize that the baseline was not labeled clearly. In our notation, p=0,q=0p=0,q=0 exactly recovers the original ParaDiGMS method: p=0p=0 uses the original Euler correction and q=0q=0 uses the original no-special-initialization rule. The setting p=0,q=1p=0,q=1 changes only the future-state initialization while keeping the model, solver, time grid, tolerance, prompts, seeds, hardware, and parallel framework fixed. Therefore, this is the controlled comparison requested by the reviewer.

For clarity, the corresponding RMSE-controlled results from Table 1 are reproduced below with explicit speedup and NFE columns. We retain the “Steps” terminology used in the paper. Each Step evaluates eight states in parallel, so

NFE=Steps×8.\mathrm{NFE}=\mathrm{Steps}\times 8.
Nominal steps Method Steps ↓\downarrow NFE ↓\downarrow Time (s) ↓\downarrow Speedup vs. q=0q=0 ↑\uparrow CLIP ↑\uparrow RMSE ↓\downarrow
25 Original ParaDiGMS (p=0,q=0p=0,q=0) 7.926 63.408 3.271 1.000×1.000\times 26.3 0.142
25 ParaDiGMS + ours (p=0,q=1p=0,q=1) 7.430 59.440 3.088 1.059×1.059\times 26.3 0.142
50 Original ParaDiGMS (p=0,q=0p=0,q=0) 15.243 121.944 6.385 1.000×1.000\times 26.1 0.097
50 ParaDiGMS + ours (p=0,q=1p=0,q=1) 13.282 106.256 5.581 1.144×1.144\times 26.1 0.098
100 Original ParaDiGMS (p=0,q=0p=0,q=0) 33.295 266.360 14.409 1.000×1.000\times 26.0 0.034
100 ParaDiGMS + ours (p=0,q=1p=0,q=1) 27.566 220.528 11.948 1.206×1.206\times 26.0 0.035

Thus, at 50 steps, adding our initialization reduces the average Steps from 15.243 to 13.282 and the aggregate NFE from 121.944 to 106.256 (a 12.9% reduction), while reducing time from 6.385 s to 5.581 s (1.144×1.144\times) with essentially matched CLIP and RMSE. For context, the 50-step sequential Euler time is 22.788 s, so the total speedup over sequential sampling increases from 3.57×3.57\times for original ParaDiGMS to 4.08×4.08\times after adding our initialization.

The headline 1.25×1.25\times and 1.49×1.49\times gains in the abstract use the fixed-tolerance protocol (tol=1.0\mathrm{tol}=1.0) in Figures 4 and 5, whereas Table 1 uses an RMSE-controlled protocol. The current paper requires the reader to infer both the denominator and this protocol difference. We will relabel p=0,q=0p=0,q=0 as “Original ParaDiGMS,” add a speedup column to the main comparison tables, and explicitly separate (a) total speedup over sequential sampling from (b) the additional initialization speedup over q=0q=0.

Q2: Why Figures 7 and 8 differ from the sequential outputs

We agree that Figures 7 and 8 differ visibly from the displayed sequential outputs. These examples were intentionally selected to expose human-recognizable strengths and weaknesses of different correction orders, rather than to demonstrate pixel-level identity. In Figure 7, the prompt explicitly requests “a cheerful cartoon character.” This attribute is largely absent for p=0p=0 and p=1p=1, but appears clearly for p=2p=2, showing better prompt consistency from the higher-order correction. In Figure 8, higher-order pp produces a richer scene with more food, tableware, and background content.

Thus, the main visual differences across these figures arise from the correction order pp, which changes the numerical trajectory. By contrast, results with different initialization orders qq are broadly similar when pp is fixed, since qq mainly affects convergence efficiency. CLIP reports an average semantic score and RMSE only measures the magnitude of pixel differences; neither directly expresses these human-recognizable advantages and disadvantages of an individual example. We will clarify the selection purpose and this distinction in the captions.

Q3: Explicit NFE accounting

Yes. With eight parallel workers,

NFE=Steps×8.\mathrm{NFE}=\mathrm{Steps}\times 8.

Here, Steps denotes the effective parallel correction steps reported in the paper. For example, at 50 steps with p=0p=0, our q=1q=1 initialization reduces NFE from 15.243×8=121.94415.243\times8=121.944 to 13.282×8=106.25613.282\times8=106.256, a 12.9% reduction. The fractional values result from averaging over 1,000 prompts. We will retain the “Steps” column and clarify its relationship to NFE in the caption.

We sincerely thank the reviewer again for these helpful comments. We hope the above clarification addresses the reviewer’s concerns and makes our empirical claims more transparent. We would greatly appreciate any further suggestions on how the presentation or evaluation could be improved, and we welcome continued discussion.

Authors · CommentOpenReview ↗

Dear Reviewer cG6a,

Thank you again for your time and effort in reviewing our NeurIPS submission 22810. At your convenience, we would greatly appreciate it if you could review our rebuttal and let us know whether it addresses your concerns. We also welcome any further feedback or questions.

Best regards,
The Authors

Reviewer vpVKOpenReview ↗
Rating
4/6
Confidence
2/5
Quality
3/4
Clarity
4/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper addresses the temporal-sequential bottleneck of sampling in Flow Matching (FM), and proposes a parallel-sampling predictor–corrector framework called ParaPC-FM. The contribution are as follows:

  • The method reuses previously computed velocity predictions vθ(xtℓ−m,tℓ−m)v_\theta(x_{t_{\ell-m}}, t_{\ell-m}) to construct a qq-th order truncated estimate of future states.
  • Parallel predictor–corrector solver: A UniC-style cross-time velocity-difference correction term Dm(u)D_m^{(u)} is integrated into the parallel update rule, enabling (p+1)(p+1)-th order local accuracy by exploiting velocity information at multiple time states within one window iteration.
Strengths and weaknesses

Strengths:

  • The paper is very clearly written.
  • The paper identifies the inefficiency of conventional Flow Matching samplers, where the prediction of each state depends on the preceding states. Accelerating sampling through parallel sampling is a valuable direction.
  • The experiments are extensive, and the ablation studies are very thorough.

Weakness:

  • Experiments use 8 NPUs. Yet at FLUX.1-dev 50 steps, the reported speedup is only 1.25x. This would greatly limit the practical value and throughput.
  • The paper seems to lack a proper comparison with other parallel sampling baselines.
Questions
  • The abstract states that ParaPC-FM "reduces correction iterations and NFEs with almost no additional overhead" (lines 9–10). Could the authors clarify this point? how many NFEs this method can save?
  • For flow matching, step distillation is a commonly adopted acceleration technique and can often provide speedups of around 10×. In that case, it seems that the method proposed in this paper may not be applicable. Is this correct?
Limitations

yes

Formatting concerns

No

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely thank the reviewer for the careful reading of our paper, the positive assessment of its clarity, motivation, and experimental coverage, and the thoughtful comments on its practical significance. The questions concerning practical acceleration, baseline comparisons, NFE accounting, and the relation to step distillation are highly valuable and help us identify several places where the presentation should be made more precise. In particular, we agree that the current paper does not clearly distinguish (i) the overall acceleration over sequential sampling from (ii) the additional acceleration contributed by our initialization module. We will revise the paper to make this distinction explicit.

W1: Practical value and the use of eight NPUs

We apologize that the reported speedup was not sufficiently clear. The 1.25×1.25\times result is obtained under tol=1.0\mathrm{tol}=1.0 and denotes the additional initialization speedup over the already-parallel q=0q=0 baseline, rather than the overall speedup over sequential sampling. Table 1 instead reports the RMSE-controlled FLUX.1-dev 50-step results under tol=0.5\mathrm{tol}=0.5. For p=0p=0:

Method Time (s) ↓\downarrow Speedup vs. sequential Additional speedup vs. ParaDiGMS
Sequential Euler 22.788 1.00×1.00\times --
Original ParaDiGMS (p=0,q=0p=0,q=0) 6.385 3.57×3.57\times 1.00×1.00\times
ParaDiGMS + our initialization (p=0,q=1p=0,q=1) 5.581 4.08×4.08\times 1.14×1.14\times

Under tol=0.5\mathrm{tol}=0.5, the original ParaDiGMS baseline achieves a 3.57×3.57\times overall speedup over sequential sampling, while adding our initialization increases the overall speedup to 4.08×4.08\times, corresponding to an additional 1.14×1.14\times acceleration over ParaDiGMS with comparable quality. We will revise the paper to report the tolerance and speedup denominator explicitly whenever a speedup is stated.

W2: Comparison with parallel-sampling baselines

We agree that the original baseline names were not sufficiently explicit. In our notation, p=0,q=0p=0,q=0 exactly recovers the original ParaDiGMS update and initialization. In addition, Table 4 uses the original ParaTAA DDIM implementation as its q=0q=0 baseline and changes only the initialization when q>0q > 0. The matched comparisons are:

Parallel framework Original baseline: steps / time With our q=1q=1 initialization: steps / time Speedup
ParaDiGMS, FLUX.1-dev, 50 steps 15.243 / 6.385 s 13.282 / 5.581 s 1.144×1.144\times
ParaTAA DDIM, SD1.5, 50 steps 20.794 / 1.738 s 18.144 / 1.481 s 1.174×1.174\times

These results compare each method against its original implementation under matched model, prompts, hardware, and sampling configuration; the absolute times across the two rows should not be compared because they use different models and hardware. We will relabel p=0,q=0p=0,q=0 as “ParaDiGMS (original baseline),” relabel ParaTAA q=0q=0 similarly, and add explicit speedup columns. We will also include the added simple extrapolation baselines described in our response to Reviewer C9hF to better isolate the benefit of the proposed initialization rule.

Q1: How many NFEs are saved, and what does “almost no additional overhead” mean?

Thank you for requesting an explicit accounting. In our eight-device implementation, each effective parallel correction step evaluates eight states, so

NFE=8×effective correction steps.\mathrm{NFE}=8\times\text{effective correction steps}.

For the representative Euler configuration (p=0p=0), the proposed q=1q=1 initialization gives:

FLUX.1-dev setting tol\mathrm{tol} ParaDiGMS q=0q=0 NFE ParaPC-FM q=1q=1 NFE NFE saved Reduction Time reduction
25 steps 1.0 63.408 59.440 3.968 6.3% 3.271 s →\to 3.088 s
50 steps 0.5 121.944 106.256 15.688 12.9% 6.385 s →\to 5.581 s
100 steps 0.4 266.360 220.528 45.832 17.2% 14.409 s →\to 11.948 s

The fractional values arise because the effective steps and NFEs are averaged over 1,000 prompts. Similar reductions are observed for the higher-order update configurations: at 50 steps, q=1q=1 saves 13.888–15.688 NFEs (10.5%–12.9%) across p∈0,1,2p\in\\{0,1,2\\}; at 100 steps, it saves 28.048–45.832 NFEs (11.4%–17.2%).

“Almost no additional overhead” means that the initialization itself introduces zero additional neural-network evaluations. It only forms linear combinations of velocity predictions that have already been computed and cached. There is a small tensor-arithmetic and indexing cost, so we will replace any wording that could be read as literally zero computational cost with the more precise statement: “no additional model evaluations and negligible arithmetic overhead relative to a model forward pass.” We will add an explicit NFE column and definition to the revised paper.

Q2: Relation to step distillation

We agree with the reviewer that ParaPC-FM is generally not suitable for aggressively distilled models with only a few sampling steps. Our method requires a sufficient number of time steps to expose useful time parallelism and to reuse past velocity information, whereas few-step distillation leaves limited parallelism and introduces larger step sizes that can weaken initialization accuracy. Therefore, ParaPC-FM is mainly intended for pretrained models that still require moderate or large numbers of sampling steps, especially when retraining or distillation is unavailable. We will clarify this scope in the revision.

We sincerely thank the reviewer again for these constructive and insightful comments. They have helped us clarify the practical scope, evaluation protocol, and positioning of ParaPC-FM. These revisions will make our claim more precise: ParaPC-FM is a training-free, plug-and-play module that provides an additional reduction in correction NFEs and single-sample latency on top of existing time-parallel samplers; it does not claim ideal linear scaling with device count or universal superiority to aggressive step distillation. We would greatly appreciate any further suggestions from the reviewer and would be very happy to continue the discussion or provide additional clarification.

Authors · CommentOpenReview ↗

Dear Reviewer vpVK,

Thank you again for your time and effort in reviewing our NeurIPS submission 22810. At your convenience, we would greatly appreciate it if you could review our rebuttal and let us know whether it addresses your concerns. We also welcome any further feedback or questions.

Best regards,
The Authors

Reviewer 5DzfOpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
2/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper accelerates parallel-in-time sampling for flow-matching and diffusion models. Parallel-in-time methods (e.g. ParaDiGMS) advance many trajectory states simultaneously and refine them with Picard-style fixed-point iterations; their cost is the number of correction rounds needed to converge, which is dominated by the quality of the initial guess for the future states. ParaPC-FM ports the machinery of UniPC into this setting. UniPC (Unified Predictor-Corrector; Zhao et al., NeurIPS 2023) is a training-free high-order ODE solver for sequential diffusion/flow sampling: its predictor (UniP) extrapolates the next state from a weighted combination of past model evaluations, and its corrector (UniC) refines that step using the fresh evaluation at the new point, with the combination weights obtained by matching Taylor moments to achieve a target order of accuracy. ParaPC-FM's main component is a UniP-style truncated initialization that reuses already-computed past velocity predictions to form higher-order (extrapolated) guesses of future states, which is training-free, plug-and-play, and adds almost no compute. It also adds a UniC-style parallel-computable correction, and decouples the update order p (solver accuracy) from the initialization order q (initialization accuracy), with coefficients obtained by moment-matching (a small Vandermonde system). On a ParaDiGMS-style framework the method reports wall-clock speedups of roughly 1.06x to 1.25x at 50 steps and 1.30x to 1.49x at 100 steps on FLUX.1-dev, 1.03x to 1.22x on Stable Diffusion 3 and 3.5 at 50 steps, and 1.14x to 1.17x when the initialization is transferred to ParaTAA, with CLIP, ImageReward, and RMSE reported as nearly unchanged. The speedup is defined relative to the no-special-initialization (q=0) baseline within the same framework.

Strengths and weaknesses

Strengths

Quality and Clarity. The numerical machinery is principled and correctly grounded in UniPC: the predictor-corrector structure, the moment-matching coefficients, and the decoupling of update order p from initialization order q are all clean and clearly presented. The central idea, reusing past velocity predictions to build a higher-order guess of future states at essentially no extra cost, is sensible, and the "almost free overhead" claim is credible because the initialization is just a linear combination of velocities that have already been computed. The evaluation is reasonably broad (FLUX.1-dev, SD3, SD3.5, plus a ParaTAA transfer) and, notably, well designed: the RMSE-controlled protocol, where the tolerance is tuned to hold RMSE roughly constant across q so that the speedup is isolated from quality changes, is a thoughtful way to avoid silently trading fidelity for speed. The transfer to ParaTAA is good evidence that the initialization is not tied to one specific parallel framework. The limitations section is candid about the low-step regime and about q=2 sometimes producing negative acceleration.

Weakness

Originality is incremental. The technical tools (UniP predictor, UniC corrector, Vandermonde moment-matching) come directly from UniPC. The contribution is to use UniP-style extrapolation to initialize future states in a parallel sampler and a UniC-style correction in the parallel update. This is a reasonable and useful combination, but it is essentially porting an existing high-order sequential solver into the parallel-initialization setting, and for nearly-straight flow-matching paths the effective recipe reduces to a low-order velocity extrapolation. The novelty is moderate.

Effectiveness is hard to assess from what is reported, and the qualitative figures cannot establish it. Because ParaPC-FM is a solver that, by construction, converges to the same output as sequential sampling up to the tolerance, the generated images are supposed to look identical to the baseline. Qualitative figures therefore only confirm that the parallel solver does not corrupt the output; they cannot demonstrate the actual contribution, which is a speed-versus-quality improvement and is invisible in a picture. Effectiveness here is a quantitative claim and must be shown as a speed-quality tradeoff, which the paper does not present in a way that settles the question.

"Quality nearly unchanged" rests on insensitive metrics. CLIP scores are essentially flat (26.0 to 26.3 across all settings) and ImageReward is flat (about 0.84 to 0.85); neither can detect the relevant degradations. The informative metric, RMSE against the same-order sequential reference, actually rises to about 0.10 to 0.14 (normalized to [0,1]) at the aggressive tolerance settings that produce the headline speedups. A 10 to 14 percent RMS deviation is not self-evidently imperceptible, and there is no FID or human evaluation to confirm the quality claim.

Questions

A speed-quality Pareto curve with a sensitive metric CLIP and ImageReward are too insensitive to support "quality nearly unchanged," and the RMSE against the sequential reference rises to about 0.10 to 0.14 at the aggressive settings. How about a sensitive quality metric (FID against the sequential-reference distribution, or human preference)? Current tables and qualitative figures do not show the effectiveness of ParaPC-FM.

Limitations

Partly addressed. The authors candidly discuss the low-step / large-step-size regime where truncation error weakens the initialization, and they note that q=2 can yield negative acceleration. These are the right limitations to raise.

Final justification

The authors corrected a misreading in my review regarding the RMSE reference, supplied the matched-step fidelity results that my main concern turned on, and committed to speedup-versus-fidelity plots and to wording that names the trade-off explicitly. I will raise the score from 3 to 4.

Formatting concerns

Not Applicable

5 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We sincerely thank the reviewer for the careful, thoughtful, and constructive review. We especially appreciate the recognition of our numerical motivation, the principled connection to UniPC, the RMSE-controlled evaluation protocol, and the transferability to ParaTAA. The reviewer's questions about the interpretation and sensitivity of the quality metrics are highly valuable: they helped us identify where the original presentation was insufficiently explicit and motivated us to provide matched-step RMSE results, additional ImageReward results, and a clearer account of the speed--fidelity trade-off. We are grateful for the opportunity to clarify these points below.

Clarifying the RMSE reference and the controlled comparison

We apologize that the reference protocol was not sufficiently explicit. In the main FLUX results (Table 1), RMSE is computed against a fixed 100-step sequential reference using the corresponding update-order solver. Thus, at 25 or 50 nominal steps, this RMSE contains both (i) the ordinary discretization gap to the 100-step reference and (ii) the additional deviation due to parallel early stopping. It is not the error relative to a same-step sequential run and should neither be read as a percentage of perceptual degradation nor as the isolated quality loss caused by ParaPC-FM.

For the comparison of initialization orders, the relevant fact is that, at a fixed model/step budget/update order, the tolerance is shared across qq and is selected to keep the reference-fidelity level comparable across qq (the complete settings are in Appendix Table 5). In the RMSE-controlled comparisons, the RMSE variation across qq is within 0.001 whenever possible. Therefore, the lower correction-round count and wall-clock time for q>0q>0 are not obtained by relaxing the early-stopping criterion for the initialized method.

The tolerance sweep is intended to expose the expected speed--fidelity trade-off: looser tolerance yields fewer correction rounds and higher speedup but a larger deviation from the sequential reference. We will make this more explicit in the revision with speedup-versus-reference-fidelity plots, and clearly distinguish the fixed 100-step reference in the main results from the fixed-budget reference used in the tolerance study.

On ImageReward, FID, and quality evaluation

We agree that no single metric is sufficient to establish generation quality, and we clarify how ImageReward (IR) is used in our evaluation. IR is a learned preference metric trained from human-feedback data rather than a direct human study. In our preliminary metric screening, it was the most responsive preference-oriented metric we tested. Its values occupy clearly different ranges across the evaluated model families: approximately 0.80!∼!0.900.80\\!\sim\\!0.90 for FLUX.1-dev, 0.65!∼!0.680.65\\!\sim\\!0.68 for SD3/SD3.5, and negative values (approximately −0.30-0.30) for the SD1.5/ParaTAA setting. These observations indicate that IR is not intrinsically constant or unable to distinguish substantially different output regimes.

We also considered FID during metric selection but did not report it because it was unreliable under our evaluation conditions. First, our main evaluation contains only 1,000 samples, a small-sample regime in which empirical FID estimates can have substantial bias and variance. Second, we do not have a single matched real-image reference distribution corresponding to the training/evaluation distribution of all three pretrained models. We preliminarily computed FID using MS-COCO as the reference; all values were above 50 and changed little across settings. More importantly, several SD outputs that were visibly worse received lower (nominally better) FID than FLUX outputs. This reversal indicates that, in our setting, the result was dominated by mismatch between the generated distribution and the chosen MS-COCO reference rather than by the subtle degradation caused by parallel early stopping. We therefore chose not to present these FID numbers as quality evidence. Using sequential outputs as the FID reference would avoid the MS-COCO domain mismatch, but an FID computed from only 1,000 samples would remain noisy and would discard the one-to-one correspondence in prompt, initial noise, and solver order. In this paired setting, RMSE against the corresponding sequential output is a more direct measure of the deviation introduced by parallel inference, while IR measures preference-oriented quality. FID/KID would be a useful complementary distribution-level evaluation with a substantially larger sample set.

To make this quality control explicit, we provide the following IR and RMSE results. For FLUX.1-dev, the supplementary 25- and 50-step RMSE values are computed against the sequential reference at the same sampling-step budget, thereby separating parallel-inference error from the discretization gap to the 100-step reference; the 100-step RMSE values are copied from Table 1. The SD3/SD3.5 table supplements the RMSE already reported in Table 3 with IR. Together, these results show that IR and RMSE remain tightly controlled across qq, while the main tables report the corresponding reductions in correction rounds and inference time.

Supplementary results on FLUX.1-dev.

Update order Init. order 25-step IR ↑\uparrow 25-step RMSE ↓\downarrow 50-step IR ↑\uparrow 50-step RMSE ↓\downarrow 100-step IR ↑\uparrow 100-step RMSE ↓\downarrow
p=0p=0 (Euler) Seq. 0.797 – 0.842 – 0.892 –
q=0q=0 0.797 0.040 0.846 0.036 0.892 0.034
q=1q=1 0.796 0.041 0.845 0.036 0.890 0.035
q=2q=2 0.798 0.041 0.843 0.036 0.893 0.035
p=1p=1 (Heun) Seq. 0.801 – 0.848 – 0.895 –
q=0q=0 0.801 0.075 0.847 0.076 0.894 0.072
q=1q=1 0.802 0.075 0.848 0.077 0.894 0.072
q=2q=2 0.800 0.075 0.848 0.076 0.892 0.072
p=2p=2 (UniPC-2) Seq. 0.801 – 0.853 – 0.902 –
q=0q=0 0.800 0.054 0.851 0.060 0.903 0.059
q=1q=1 0.798 0.054 0.852 0.060 0.904 0.059
q=2q=2 0.800 0.054 0.852 0.060 0.903 0.059

The relatively larger matched-step RMSE for p=1p=1 should be interpreted in light of the sequential reference cost. The p=1p=1 reference uses Heun's method and, under our solver's step-count convention, an NN-step trajectory requires approximately 2N−12N-1 NFEs. For example, the nominal 25-step reference uses 49 NFEs, and the 50- and 100-step references scale analogously. Consequently, comparisons across different pp values at the same nominal step count do not correspond to matched NFE budgets. The Heun reference is computed with a substantially larger evaluation budget, making it a stricter trajectory reference and leading to a somewhat larger RMSE for the tolerance-terminated parallel result. Importantly, our initialization comparison is made within each fixed pp: the reference solver, nominal step count, tolerance, and NFE convention are identical across qq. Thus, this cross-order difference does not affect the conclusion that initialization reduces correction rounds at matched fidelity within each update order.

Supplementary 50-step results on Stable Diffusion 3 and Stable Diffusion 3.5.

Model Update order IR (Seq.) ↑\uparrow IR (q=0q=0) ↑\uparrow IR (q=1q=1) ↑\uparrow IR (q=2q=2) ↑\uparrow
SD3 p=0p=0 (Euler) 0.653 0.651 0.652 0.653
SD3 p=1p=1 (Heun) 0.663 0.664 0.665 0.663
SD3 p=2p=2 (UniPC-2) 0.681 0.679 0.680 0.679
SD3.5 p=0p=0 (Euler) 0.658 0.658 0.658 0.659
SD3.5 p=1p=1 (Heun) 0.672 0.672 0.671 0.672
SD3.5 p=2p=2 (UniPC-2) 0.679 0.678 0.679 0.680

We will soften the paper's wording from “quality nearly unchanged” to: “Under the matched-tolerance protocol and reported reference-fidelity and preference metrics, ParaPC-FM improves parallel sampling time without a substantial observed quality degradation; aggressive tolerance settings explicitly entail a speed--fidelity trade-off.”

We sincerely thank the reviewer again for the time and care invested in evaluating our work. We hope that the clarifications and additional results above make our evaluation protocol and empirical claim substantially clearer: under controlled quality and reference-fidelity settings, the proposed nearly free initialization reduces parallel correction rounds and improves inference efficiency. We would be very grateful for any further questions, suggestions, or concerns, and we warmly welcome continued discussion with the reviewer.

Authors · CommentOpenReview ↗

Dear Reviewer 5Dzf,

Thank you again for your time and effort in reviewing our NeurIPS submission 22810. At your convenience, we would greatly appreciate it if you could review our rebuttal and let us know whether it addresses your concerns. We also welcome any further feedback or questions.

Best regards,

The Authors

Authors · CommentOpenReview ↗

Dear Reviewer 5Dzf,

Thank you for your time and effort in reviewing our NeurIPS submission 22810. As the rebuttal phase is drawing to a close tomorrow, we would like to express our sincere gratitude for your thorough and constructive feedback. We look forward to receiving any further comments you may have.

Best regards,

The authors

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…