potentialpaper

Fine-tuning speech models on slow fMRI improves prediction for fast ECoG

Aditya R. Vaidya, Richard Antonello, Alexander Huth

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. Speech models fine-tuned to predict fMRI, a slow recording of brain activations, can be used to build better models of much faster intracranial brain recordings.

Abstract. Neuroscientists have recently turned to intracranial brain recording methods, like electrocorticography (ECoG), for human experiments because of the fine spatial and temporal resolution that they afford. Models trained on this data, however, are fundamentally restricted by the patient populations that can receive the implants necessary for recording. We propose using non-invasive fMRI to bridge the gap in training data. Using spoken language representations fine-tuned on fMRI, we build encoding models of ECoG. These representations show improved prediction performance in ECoG, even though the temporal resolution of fMRI is two orders of magnitude worse. Prediction improves in frequency bands well beyond what is directly measured in fMRI. Next, to test the procedure's generalization ability, we fine-tune models on fMRI responses that are temporally downsampled by a factor of 2. Despite the loss in resolution, these models are able to predict fMRI and ECoG responses at levels comparable to the original fMRI-tuned models. Finally, we show that ECoG performance steadily scales with the amount of fMRI-tuning data. Our results show that "slow" data like fMRI can be a valuable resource for building better models of "fast" brain data like ECoG. In the future, integrating across multiple recording methods may further improve performance in other applications, like decoding.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
4 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:44 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The authors propose an innovative approach for ECoG language encoding models using fMRI, despite the fact that fMRI has low temporal resolution. They use fMRI responses to spoken narratives to fine-tune WavLM Base+ and then use its speech representations to predict ECoG responses.

The reviewers found the problem important and the approach interesting and were overall quite positive, but with several important concerns that the authors could address during the rebuttal period, including the fact that the evaluation is limited to a single speech model and lacks additional baselines such as stimulus-only tuning and that the ECoG model was fairly simple (ridge regression) and evaluated only on a single dataset.

Final justification

The authors have provided a detailed rebuttal, and while some concerns remain, all of the reviewers are leaning towards acceptance. The remaining concerns are primarily regarding the broader interpretation of the findings, which suggests that fMRI tuning may produce “more brain-like representations” and the conclusion that the results provide “strong evidence that brain-like representations are highly modality invariant”.

Area Chair 8xyD · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The authors propose an innovative approach for ECoG language encoding models using fMRI, despite the fact that fMRI has low temporal resolution. They use fMRI responses to spoken narratives to fine-tune WavLM Base+ and then use its speech representations to predict ECoG responses.

The reviewers found the problem important and the approach interesting and were overall quite positive, but with several important concerns that the authors could address during the rebuttal period, including the fact that the evaluation is limited to a single speech model and lacks additional baselines such as stimulus-only tuning and that the ECoG model was fairly simple (ridge regression) and evaluated only on a single dataset.

Final justification

The authors have provided a detailed rebuttal, and while some concerns remain, all of the reviewers are leaning towards acceptance. The remaining concerns are primarily regarding the broader interpretation of the findings, which suggests that fMRI tuning may produce “more brain-like representations” and the conclusion that the results provide “strong evidence that brain-like representations are highly modality invariant”.

1 comment
Area Chair 8xyD · CommentOpenReview ↗

Thank you to the authors for providing detailed responses!

Dear reviewers, please make sure to read the authors’ responses and participate in the discussion so that the authors have an opportunity to address any remaining questions.

Reviewer ptyUOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper studies an interesting question: whether low-temporal-resolution fMRI can improve language encoding models for high-temporal-resolution ECoG. The authors fine-tune WavLM Base+ on fMRI responses to spoken narratives, freeze the tuned model, and use its speech representations to predict high-gamma ECoG responses with ridge regression. The fMRI-tuned WavLM outperforms the pretrained WavLM, especially in auditory cortex and the language network. Further analyses suggest that the gains are not limited to low-frequency signals, are robust to fMRI downsampling, and increase with more fMRI-tuning data.

Strengths and weaknesses

Strengths:

  1. The research question is practically important. ECoG data are hard to collect, while fMRI data are relatively easier to obtain. Using fMRI to improve ECoG encoding models is therefore a reasonable and useful direction.
  2. The cross-recording-method setting from fMRI to ECoG is interesting. fMRI and ECoG have very different temporal resolutions, but the authors show that fMRI-tuned representations can still improve ECoG prediction.
  3. The experimental pipeline is clear. The main structure is easy to follow: spoken audio is passed through WavLM, the model is tuned with fMRI responses, the tuned WavLM is frozen, and its representations are then used for ECoG ridge regression.
  4. The use of natural language stimuli is also a strength. The fMRI data use natural spoken stories, and the ECoG data use podcasts, making the task closer to real language understanding than experiments based only on isolated words or short sentences.

Weaknesses:

  1. The experiments mainly use one speech model, WavLM Base+, with a focus on layer 9. The paper mentions HuBERT, WavLM, and Whisper as useful models for speech-brain encoding, but the main evidence here is still centered on WavLM Base+. It is not clear whether the same conclusion would hold for other speech models or other layers.
  2. The baselines are still not sufficient. The main comparison is between fMRI-tuned WavLM and pretrained WavLM, but this does not rule out the possibility that ordinary speech-related fine-tuning, regularization, or extra speech exposure could lead to similar gains. Useful baselines would include stimulus-only tuning, BigSLM target tuning, phoneme tuning, or semantic tuning. These controls would help test whether the improvement really comes from the fMRI target.
  3. The ECoG temporal model is relatively simple. The authors use single-lag ridge regression because of computational cost, rather than a full FIR model. This choice is understandable, but it may not fully capture language responses at multiple time scales in ECoG. The paper could add an FIR analysis with reduced-dimensional features, or report how stable the results are across different lags. It would also help to clarify whether the best lag is selected strictly within cross-validation.
  4. The improvement in auditory cortex may mainly reflect acoustic features, not necessarily higher-level language representations. The authors could add acoustic, phoneme, and semantic probes, or test whether fMRI-tuned WavLM still adds predictive power after controlling for acoustic and phonetic features.
  5. The ECoG evaluation uses only one Podcast dataset. The paper would be stronger with more detailed per-patient results, an analysis of how electrode coverage affects the findings, or validation on another ECoG dataset.
  6. I also noticed a citation-numbering issue: the main text refers to the “Podcast” ECoG dataset as [30], but the reference list indicates that the Podcast ECoG dataset is [29], while [30] is Antonello et al. on scaling laws for fMRI encoding models.
Questions
  1. Do the results depend on WavLM layer 9? Would other WavLM layers, HuBERT, Whisper, or wav2vec 2.0 show similar fMRI-to-ECoG transfer effects?
  2. Is the improvement mainly acoustic, phonetic, or semantic? Does fMRI-tuned WavLM still help after controlling for speech envelope, spectrogram, or phoneme-level features?
  3. The downsampled-fMRI result is interpreted as evidence for temporal generalization. Should the downsampled-fMRI result be interpreted as slow-to-fast transfer, or as robustness to low-frequency or denoised fMRI supervision?
  4. In Section 2.4, the authors fit separate ridge models for 81 lags from -2 to +2 seconds and report the best-performing lag. It is not clear whether this lag selection is done within the cross-validation loop, or whether the best lag is chosen using the same scores later reported as final performance. Could the authors clarify this? It would also help to report the selected lags across electrodes and regions, and to show whether the main results hold when the lag is fixed or more tightly constrained.
  5. Minor note: In Section 3.4, should the citation to the “Podcast” ECoG dataset be [29] rather than [30]? Section 2.4 cites the Podcast dataset as [29], and the reference list shows that [29] is the Podcast ECoG dataset, while [30] is Antonello et al. on fMRI scaling laws.
Limitations

The main limitation is that the experiments do not fully isolate the role of correctly aligned fMRI responses. The paper shows that fMRI-tuned WavLM improves ECoG encoding over pretrained WavLM, but it does not include a temporally structured mismatch control. As a result, part of the gain could still come from general speech-related fine-tuning, regularization, or domain adaptation, rather than matched fMRI supervision. Another limitation is the statistical dependence among ECoG electrodes. The dataset has many electrodes but only 9 patients, and electrodes from the same patient are not independent samples. Electrode-level tests may overstate the evidence. Patient-level results, mixed-effects analysis, or patient-wise bootstrap would make the statistical support stronger. The source of the improvement is also not fully separated. Since the largest gains appear in auditory cortex, the effect may partly reflect better acoustic or phonetic encoding, not only higher-level language representation. It would help to show whether fMRI-tuned WavLM still explains extra ECoG variance after controlling for lower-level speech features.

Final justification

I still have some concerns and would keep my original rating. The rebuttal strengthens the basic finding that fMRI tuning can improve ECoG prediction, but I am less convinced by the broader interpretation. In the paper, the authors suggest that fMRI tuning may produce “more brain-like representations” and conclude that the results provide “strong evidence that brain-like representations are highly modality invariant.” However, in the new controls, the LLaMA-tuned, word-rate-tuned, and articulation-tuned models all have numerically higher mean encoding scores than the fMRI-tuned model. This makes it unclear how much of the gain comes from brain-related information in fMRI, rather than from more general stimulus-related fine-tuning. The shuffled-fMRI control is useful and shows that alignment matters, but I do not think the new results fully resolve this concern. I therefore plan to keep my original rating.

Formatting concerns

None.

5 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank Reviewer ptyU for their time and helpful feedback. We respond point-by-point below:

Q1: Do the results depend on WavLM layer 9? Would other WavLM layers, HuBERT, Whisper, or wav2vec 2.0 show similar fMRI-to-ECoG transfer effects?

We chose layer 9 of WavLM because it had the highest baseline fMRI performance in that model, and we do not claim that the choice of layer or model is critical for our results.

We are fine-tuning additional model to address concerns about these choices, and we will update this response once they are completed.

Q2: Is the improvement mainly acoustic, phonetic, or semantic? Does fMRI-tuned WavLM still help after controlling for speech envelope, spectrogram, or phoneme-level features?

Previous work has shown that fMRI-tuning mainly improves semantic representations (Vattikonda et al. (2025); Moussa et al. (2024)). We are running controls against these low-level features and will update this response once completed.

Q4: In Section 2.4, the authors fit separate ridge models for 81 lags from -2 to +2 seconds and report the best-performing lag. It is not clear whether this lag selection is done within the cross-validation loop, or whether the best lag is chosen using the same scores later reported as final performance. Could the authors clarify this? It would also help to report the selected lags across electrodes and regions, and to show whether the main results hold when the lag is fixed or more tightly constrained.

We follow the evaluation procedure used in the original dataset (Zada et al. (2025)). The authors find the lag with the best test performance, and report that score as the performance of the electrode. Selecting the best model on the test set is not ideal, and will inflate performance values. However, we chose to retain this procedure both to match earlier work on this dataset and because our metric of interest is not the absolute performance but the difference between two models that are equally affected.

Q5: Minor note: In Section 3.4, should the citation to the “Podcast” ECoG dataset be [29] rather than [30]? Section 2.4 cites the Podcast dataset as [29], and the reference list shows that [29] is the Podcast ECoG dataset, while [30] is Antonello et al. on fMRI scaling laws.

Thank you for catching this. We will fix this in the manuscript.

Authors · CommentOpenReview ↗

Addressing the remaining questions

W1/Q1: Do the results depend on WavLM layer 9? Would other WavLM layers, HuBERT, Whisper, or wav2vec 2.0 show similar fMRI-to-ECoG transfer effects?

We chose layer 9 of WavLM because it had the highest baseline fMRI performance in that model, and we do not claim that the choice of layer or model is critical for our results.

We have additionally fMRI-tuned whisper-large-v3 on the Courtois NeuroMod dataset, and we evaluate its representations on the “Podcast” ECoG dataset. After fMRI-tuning, performance increases from 0.0683 to 0.0702 (2.8% improvement) after averaging across electrodes. This setup differs in several key ways from our original setup. First, the starting model is trained for word recognition instead of a self-supervised objective (WavLM). Second, the model is simultaneously fine-tuned on multiple fMRI subjects instead of one. Third, the responses in NeuroMod are to audiovisual stimuli rather than purely audio (LeBel et al.). Despite all these differences, the fMRI-tuned Whisper model still improves at predicting ECoG.

W2: The baselines are still not sufficient. The main comparison is between fMRI-tuned WavLM and pretrained WavLM, but this does not rule out the possibility that ordinary speech-related fine-tuning, regularization, or extra speech exposure could lead to similar gains. Useful baselines would include stimulus-only tuning, BigSLM target tuning, phoneme tuning, or semantic tuning.

We fine-tuned additional WavLM models on stimulus-only features: LLaMA hidden states (semantics), wordrate (acoustic), and articulatory features (phonetic). We also fine-tuned models on fMRI responses shuffled in 10-TR blocks to show that the temporal structure in the fMRI responses is necessary. We report the results below:

Model Mean encoding perf. (ρ\rho) SEM
fMRI-tuned 0.08107 0.003183
shuffled-fMRI-tuned 0.07233 0.002976
LLaMA-tuned 0.08822 0.003248
Word rate-tuned 0.08739 0.003228
Articulation-tuned 0.08665 0.003185
Pretrained 0.06955 0.002559

The shuffled-fMRI-tuned models show a small improvement over the pretrained model, but are substantially worse than the normal fMRI-tuned models. The three stimulus-tuned models do perform well, but perhaps for different reasons. First, LLaMA hidden states are a noiseless semantic signal. in contrast with fMRI. Thus, they are a better semantic teacher for the WavLM model. Word rate is a primarily acoustic signal that would be useful for predicting auditory areas, but this speech feature may not be directly represented in the WavLM model. Hence, a small amount of fine-tuning on this signal would improve auditory performance. We believe the same is true for articulatory features.

We also note that the wordrate- and articulation- tuned models needed minimal training before early stopping, only 2 epochs, compared to a minimum 8 for all other models. This further supports the idea that these gains come from the features being simple, noiseless signals, in comparison to the braintuning, which is noisier but also is able to introduce more complex features (see response to W4/Q2).

W3: The ECoG temporal model is relatively simple. The authors use single-lag ridge regression because of computational cost, rather than a full FIR model. This choice is understandable, but it may not fully capture language responses at multiple time scales in ECoG.

We shared your concern that the simplicity of our temporal model for ECoG may not be expressive enough to capture all possible filters, but empirically, this does not appear to be an issue when evaluating the fMRI-tuned models. We fit 40-delay FIR models (t=50t=50 ms to t=2t=2 s) models on WavLM features after using PCA to reduce them to 100 dimensions. We show their performance here:

Model Mean encoding perf. (ρ\rho) SEM % improvement vs. pretrained
fMRI-tuned 0.05772 0.002968 36.59
LLaMA-tuned 0.06077 0.003084 43.79
Word rate-tuned 0.05907 0.003113 39.78
Articulation-tuned 0.06084 0.003022 43.98
Pretrained 0.04226 0.002352 0
With a full FIR model, fMRI-tuning outperforms the pretrained model by a larger margin than for the single-delay models. Note that these values cannot be directly compared to those from single-delay models from the rest of the paper. For those models, we take the maximum test performance over lags, uniformly biasing the performance upwards (see below, “Q4”). In these FIR models, we do not use the test set during model fitting.
Authors · CommentOpenReview ↗

W4/Q2: Is the improvement mainly acoustic, phonetic, or semantic? Does fMRI-tuned WavLM still help after controlling for speech envelope, spectrogram, or phoneme-level features?

To control for simpler speech features, we evaluated whether adding concatenating the WavLM features with one of these features improved ECoG performance. We used FIR models (and reduced WavLM features) because the two sets of features may perform best at different delays. In the table below, the first row shows the performance (mean ±\pm SEM) of the baseline feature only. The next two rows show the performance of the pretrained and fMRI-tuned models by themselves (column 1), or after they’ve been concatenated with one baseline feature (columns 2-4).

Model WavLM only w/ envelope w/ spectrogram w/ phonetic
Baseline only N/A 0.04034 ± 0.002177 0.04591 ± 0.002427 0.03722 ± 0.002
Pretrained WavLM 0.04226 ± 0.002352 0.05334 ± 0.002874 0.06289 ± 0.003025 0.05205 ± 0.002815
fMRI-tuned WavLM 0.05772 ± 0.002968 0.05895 ± 0.003048 0.0666 ± 0.003136 0.05808 ± 0.002987

The fMRI-tuned model outperforms all three baselines. Joint WavLM-baseline models have higher performance than the models do separately, indicating that they explain partially disjoint sets of the response. For all baselines, joint models using the fMRI-tuned WavLM improve over the joint models using the pretrained WavLM. This is evidence that fMRI-tuning adds information that is orthogonal to each of these low-level speech features.

The marginal gain of adding the baseline feature, however, is less for the fMRI-tuned model (e.g. 0.05772 alone vs. 0.0666 w/ spectrogram) than for the pretrained model (0.04226 alone vs. 0.06289 w/ spectrogram). Thus, there is some overlap between the baselines and what fMRI-tuning learns, in addition to orthogonal component.

W5: The ECoG evaluation uses only one Podcast dataset. The paper would be stronger with more detailed per-patient results, an analysis of how electrode coverage affects the findings, or validation on another ECoG dataset. [From Limitations:] Patient-level results, mixed-effects analysis, or patient-wise bootstrap would make the statistical support stronger.

As far as we know, the “Podcast” dataset is the only public ECoG dataset that uses auditory stimuli. We would be happy to extend our analyses to another dataset to demonstrate robustness.

We agree that our findings can depend on electrode coverage, which greatly varies across patients. We show the coverage and performance change for each patient’s electrodes in the Appendix (Fig. 6). Here, we quantify the mean performance (across electrodes) for each ECoG patient, before and after fMRI-tuning. We also compute paired two-sided tt-tests across electrodes within each subject.

Patient fMRI-tuned Pre-trained pp-val
01 0.096 0.0781 9.94e-10
02 0.0603 0.0513 1.61e-07
03 0.0902 0.0741 3.42e-19
04 0.0839 0.0707 6.5e-07
05 0.026 0.0296 0.00342
06 0.104 0.0885 3e-13
07 0.0702 0.0757 0.061
08 0.0976 0.0803 1.28e-06
09 0.0958 0.0764 2.64e-22

Of the nine subjects, only two do not improve after fMRI-tuning. One of these has poor performance even for the pretrained model, suggesting poor data quality. We will update the manuscript with the quantitative results above.

Following your suggestion, we also analyzed patient-level effects using linear mixed effects with the model type (pretrained or fMRI-tuned) as a fixed effect and subject-specific random intercepts. fMRI-tuned had significantly higher performance than the pretrained models with β=0.0117\beta = 0.0117, SE = 0.0043, 95% CI [0.0034, 0.0201], p=0.006p=0.006.

Q3: [...] Should the downsampled-fMRI result be interpreted as slow-to-fast transfer, or as robustness to low-frequency or denoised fMRI supervision?

The downsampled-fMRI-tuned result is evidence of slow-to-fast generalization, but also that what is being learned (semantics) is captured in the lowest-frequency signals.


Q4, and Q5/W6 were answered in the original rebuttal.

Reviewer aas2OpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
4/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

There is great interest in building encoding models using ECoG data because of its fine temporal and spatial resolution. However, ECoG data is relatively rare. Is it possible to supplement ECoG data with comparatively plentiful fMRI data? This paper builds on recent "brain-tuning" studies that show that DNNs trained to perform a difficult task (e.g. ASR) can be fine-tuned to improve neural encoding performance. It tunes a speech representation model (WavLM) using fMRI responses to speech, then uses that fine-tuned model to build a conventional linearized encoding model of ECoG responses. This work shows improved prediction of ECoG, despite the difference in temporal resolution of fMRI and ECoG. It goes on to show that the improvement is not limited to temporally coarse adjustments, as might be expected from fMRI data. It pushes this finding by halving the temporal resolution of the fMRI responses, finding this makes little difference. Lastly, the work shows that ECoG performance scales with the amount of fMRI-tuning data.

Strengths and weaknesses

Quality

Is the submission technically sound? Are claims well supported (e.g., by theoretical analysis or experimental results)? Are the methods used appropriate? Is this a complete piece of work or work in progress? Are the authors careful and honest about evaluating both the strengths and weaknesses of their work?

Yes. The fMRI-tuning procedure is sensible and the ECoG evaluation is standard. Figure 2 clearly illustrates the benefits of fMRI-tuning for predicting ECoG. Breaking the improvement into frequency bins (Fig. 3) is an interesting strategy and seems reasonable to me. The claims about lowering the temporal resolution of the fMRI-tuning data and prediction performance are justified in figures 4 and 5.

Clarity 

Is the submission clearly written? Is it well organized? Does it adequately inform the reader? A superbly written paper provides enough information for an expert reader to reproduce its results.

 

Yes, the submission is clearly written, with enough detail that I feel I could roughly reproduce the results.

Significance

Are the results impactful for the community? Are others (researchers or practitioners) likely to use the ideas or build on them? Does the submission address a difficult task in a better way than previous work? Does it advance our understanding/knowledge on the topic in a demonstrable way? Does it provide unique data, unique conclusions about existing data, or a unique theoretical or experimental approach?

This work convinces me that fine tuning on fMRI data is helpful for predicting ECoG, and that improvements are not limited to long time scales. I find it difficult to put these improvements in context, however. It would help to know how this improvement compares to a noise ceiling and to the variation you'd see from simply swapping in a different DNN. My view on the significance of these results depends on how substantial the improvement is versus the noise ceiling.

The authors show that the improvements are not limited to the coarse time scale of fMRI. I’d like to see predicted vs. measured ECoG time courses, not just correlation. If fMRI tuning substantially improves alignment of fine-scale dynamics (which, in my experience, are usually poorly captured), that would increase my appraisal of the significance.

Can the authors comment on why they fMRI-tuned separate models for each participant? Could the LoRAs have been trained jointly for all participants?

Originality

**Does the work provide new insights, deepen understanding, or highlight important properties of existing methods?**Is it clear how this work differs from previous contributions, with relevant citations provided? Does the work introduce novel tasks, problem framings, metrics, or methods that advance the field? Does this work offer a novel combination of existing techniques, and is the reasoning behind this combination well-articulated? As the questions above indicates, originality does not necessarily require introducing an entirely new method. Rather, a work that provides novel insights by evaluating existing methods, or demonstrates improved efficiency, fairness, etc. is also equally valuable.

This paper combines ideas and techniques from several recent lines of work. The reasoning behind these combinations is well articulated. I find the authors’ hypothesis about why slow-to-fast model transfer is possible to be plausible, though this seems like a rich question and I wish the authors went deeper into it. The analysis underlying figure 3 is nice, and figure 4 and 5 address practical questions one might have when considering fine tuning on fMRI data.

Questions

Please compute a noise ceiling, if possible, for the ECoG performance results. Why were fMRI models fit separately for each subject? How were these separate models reconciled when making ECoG predictions? Please consider showing time courses.

Limitations

Yes.

Final justification

Thank you for your comments. I second the comment by Reviewer WFZk that the new results raise additional questions that complicate the conclusions from the work. I have lowered my score by a point, though I still lean towards accepting the paper.

Formatting concerns

n/a

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank Reviewer aas2 for their thorough review. We respond point-by-point below:

This work convinces me that fine tuning on fMRI data is helpful for predicting ECoG, and that improvements are not limited to long time scales. I find it difficult to put these improvements in context, however. It would help to know how this improvement compares to a noise ceiling and to the variation you'd see from simply swapping in a different DNN. My view on the significance of these results depends on how substantial the improvement is versus the noise ceiling.

This is an important point, but unfortunately, there is no way to quantify the noise ceiling in this dataset because the stimulus was only presented once. To provide more context for our results, we will include results from more baselines, such as models fine-tuned only on the stimulus. We will update our response once those models have completed fitting.

Can the authors comment on why they fMRI-tuned separate models for each participant? Could the LoRAs have been trained jointly for all participants? [...] How were these separate models reconciled when making ECoG predictions?

We did this to mirror the setup of Vattikonda et al. (2025) and Moussa et al. (2024). All metrics, including ECoG performance, were calculated separately for each fMRI-tuned model (one model per fMRI participant), and we report the average across fMRI participants.

Please consider showing time courses.

As we are not allowed to include links to plots, we will include predicted timecourses in a revised version of the manuscript.

Authors · CommentOpenReview ↗

Replacement rebuttal

We answer the remaining questions from Reviewer aas2 here, and we expand upon our previous answers. For that reason, please disregard the original "Rebuttal by Authors".

S1/Q1: This work convinces me that fine tuning on fMRI data is helpful for predicting ECoG, and that improvements are not limited to long time scales. I find it difficult to put these improvements in context, however. It would help to know how this improvement compares to a noise ceiling and to the variation you'd see from simply swapping in a different DNN. My view on the significance of these results depends on how substantial the improvement is versus the noise ceiling.

This is an important point, but unfortunately, there is no way to quantify the noise ceiling in this dataset because the stimulus was only presented once. To provide more context for our results we fine-tuned new WavLM models on stimulus-only features: LLaMA hidden states (semantics), wordrate (acoustic), and articulatory features (phonetic). We also fine-tuned models on fMRI responses shuffled in 10-TR blocks to show that the temporal structure in the fMRI responses is necessary. We report the results below:

Model Mean encoding perf. (ρ\rho) SEM
fMRI-tuned 0.08107 0.003183
shuffled-fMRI-tuned 0.07233 0.002976
LLaMA-tuned 0.08822 0.003248
Word rate-tuned 0.08739 0.003228
Articulation-tuned 0.08665 0.003185
Pretrained 0.06955 0.002559

The shuffled-fMRI-tuned models show a small improvement over the pretrained model, but are substantially worse than the normal fMRI-tuned models. The three stimulus-tuned models do perform well, but perhaps for different reasons. First, LLaMA hidden states are a noiseless semantic signal. in contrast with fMRI. Thus, they are a better semantic teacher for the WavLM model. Word rate is a primarily acoustic signal that would be useful for predicting auditory areas, but this speech feature may not be directly represented in the WavLM model. Hence, a small amount of fine-tuning on this signal would improve auditory performance. We believe the same is true for articulatory features.

We also note that the wordrate- and articulation- tuned models needed minimal training before early stopping, only 2 epochs, compared to a minimum 8 for all other models. This further supports the idea that these gains come from the features being simple, noiseless signals, in comparison to the braintuning, which is noisier but also is able to introduce more complex features.

We have additionally fMRI-tuned a different backbone — whisper-large-v3 — on the Courtois NeuroMod dataset, and we evaluate its representations on the “Podcast” ECoG dataset. After fMRI-tuning, performance increases from 0.0683 to 0.0702 (2.8% improvement) after averaging across electrodes. See the question below about “separate models for each participant” for more details about this model.

S2: The authors show that the improvements are not limited to the coarse time scale of fMRI. I’d like to see predicted vs. measured ECoG time courses, not just correlation. If fMRI tuning substantially improves alignment of fine-scale dynamics (which, in my experience, are usually poorly captured), that would increase my appraisal of the significance.

We believe the spectrum of the residual (Fig. 3) demonstrates that we do improve the alignment of fine-scale dynamics. The residual decreases in the highest frequency bands, which necessarily means that we improve the alignment at those scales. We will also show predicted timecourse plots in the final manuscript.

Authors · CommentOpenReview ↗

S3/Q2/Q3: Can the authors comment on why they fMRI-tuned separate models for each participant? Could the LoRAs have been trained jointly for all participants? [...] How were these separate models reconciled when making ECoG predictions?

We did this to mirror the setup of Vattikonda et al. (2025) and Moussa et al. (2024). All metrics, including ECoG performance, were calculated separately for each fMRI-tuned model (one model per fMRI participant), and we report the average across fMRI participants.

fMRI-tuning on responses from multiple participants is feasible. To show this, we have additionally fMRI-tuned whisper-large-v3 on the Courtois NeuroMod dataset by fine-tuning it simultaneously on all 6 participants’ data. We evaluate its representations on the “Podcast” ECoG dataset and find performance increases from 0.0683 to 0.0702 (2.8% improvement) after averaging across electrodes. In addition to using multiple fMRI-tuning subjects, this setup differs in two key ways from our original setup. First, the starting model is trained for word recognition instead of a self-supervised objective (WavLM). Second, the responses in NeuroMod are to audiovisual stimuli rather than purely audio (LeBel et al.). Despite all these differences, the fMRI-tuned Whisper model still improves at predicting ECoG.

Q4: Please consider showing time courses.

As we are not allowed to include links to plots in our responses, we will include predicted timecourses in a revised version of the manuscript.

Reviewer WFZkOpenReview ↗
Rating
4/6
Confidence
5/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper addresses the limited availability of ECoG data (to build encoding models) by leveraging large-scale fMRI datasets. The authors fine-tune a pretrained language model using a large public fMRI dataset and then extract embeddings from this "fMRI-tuned" language model to build encoding models using limited ECoG data. They show that fMRI tuning consistently improves ECoG encoding performance compared to encoding models built using the corresponding pretrained model. Interestingly, the improvements extend to ECoG frequency bands that are not directly measured by fMRI.

To better understand this, the authors repeat the fine-tuning using fMRI data downsampled by a factor of two and observe similar improvement. Further, they show that ECoG encoding performance scales with the amount of fMRI data used to fine-tune the language model.

Strengths and weaknesses

The paper addresses an important practical limitation in encoding research: the scarcity of large ECoG datasets due to the limited patient population. Using large public fMRI datasets to brain-tune language models before building ECoG encoding models is a neat idea. The experiments demonstrate that fMRI fine-tuning consistently improves ECoG encoding performance. The scaling analysis showing that performance continues to improve as more fMRI data are used for fine-tuning is a meaningful contribution.

The paper is generally well written and easy to follow. However, some wording in the introduction is misleading. Throughout the paper, it is the language model that is fine-tuned on fMRI data, while the encoding models are subsequently constructed from the resulting embeddings. Several sentences instead describe the encoding models themselves as being fine-tuned, which is technically inaccurate and may confuse readers. For example, phrases such as "encoding models fine-tuned on fMRI" and "ECoG prediction performance compared to the pretrained model" should be reworded for clarity. The title is also somewhat misleading, as it suggests that the encoding models themselves are fine-tuned

While the proposed approach is convincing, all experiments are conducted using a single pretrained model (WavLM). It is therefore unclear whether the observed improvements are general or specific to this architecture. Replicating the analyses using another speech or language model would substantially strengthen the conclusions.

Another limitation is the lack of baselines. The current comparisons do not isolate whether the observed improvements arise specifically from fMRI-tuning or simply from additional fine-tuning. Useful baselines would include fine-tuning using features from another speech model, the speech envelope of the stimuli, or simulated signals with varying frequency content. Including the same baselines in the scaling analysis would further strengthen the conclusions.

The paper also leaves open why the improvements transfer to frequency bands that are not directly measured by fMRI. The discussion could be further expanded for this. In particular, EEG provides substantially higher temporal resolution than fMRI while remaining much cheaper to acquire. Discussing whether the proposed framework could also benefit from "EEG-tuning" would broaden the implications of the work.

Finally, several experimental observations would benefit from additional explanation. The largest improvements appear in the auditory cortex, but it is unclear why this region mainly benefits most. It would be useful to discuss whether this reflects higher ECoG signal quality or another factor. Similarly, the paper reports that fMRI signals have particularly high SNR in the 0.01–0.1 Hz range, yet improvements are also observed for ECoG encoding models in the 0.1–0.25 Hz range. This deserves further discussion.

Overall, the proposed framework is well motivated, technically sound, and demonstrates promising improvements in ECoG encoding performance. However, stronger baselines, validation across additional pretrained models, and further discussion of the mechanisms underlying the observed improvements would substantially strengthen the paper.

Questions
  • All experiments are performed using WavLM. Could the authors replicate the main analyses using another pretrained speech or language model to demonstrate that the observed improvements are not specific to this architecture?

  • The current comparisons do not isolate whether the improvements arise specifically from fMRI-tuning or simply from additional fine-tuning. Could the authors include additional baselines as mentioned above? -The largest encoding performance improvements appear in the auditory cortex. Could the authors explain why this region benefits most? Could the authors report the SNR of the ECoG data?

  • The fMRI and ECoG datasets contain different stimuli. How semantically or conceptually similar are the two stimulus sets? A simple visualization (e.g., MDS or t-SNE of the stimuli in WavLM embedding space) would help assess the degree of overlap and the generalizability of the proposed approach. Especially, given that each ECoG participant contributes only approximately 30 minutes of data.

  • Some clarifications:

    • Is Figure 3 averaged across participants? The y-axis values appear very small; is this expected?
Limitations

Yes.

Final justification

In the rebuttal, the authors added experiments with another model class and clarified that the stimulus statistics of the fMRI and ecog datasets are different. However, the new baselines raise further questions rather than strengthening the central claim. Since fine-tuning with alternative signals performs as well as or better than fMRI, it remains unclear if/what fMRI even contributes to improving ECoG prediction. The improvements shown with variance partitioning are very small to be deemed as proof of the central claim.

Formatting concerns
  • The title is somewhat misleading, as it suggests that the encoding models themselves are fine-tuned.
  • Several sentences in the introduction (last paragraph of page 2) should be reworded for clarity to distinguish language model fine-tuning from encoding model fine-tuning.
  • Figure 2C is missing a colorbar label.
5 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank Reviewer WFZk for their thorough review. We respond point-by-point below:

The paper also leaves open why the improvements transfer to frequency bands that are not directly measured by fMRI. The discussion could be further expanded for this. In particular, EEG provides substantially higher temporal resolution than fMRI while remaining much cheaper to acquire. Discussing whether the proposed framework could also benefit from "EEG-tuning" would broaden the implications of the work.

EEG does have higher temporal resolution than fMRI, so it is possible that EEG-tuning would be beneficial like fMRI-tuning. However, we see two reasons why it may fall short of fMRI-tuning. First, it is unable to reliably record the high-gamma signal used in ECoG. Second, its spatial resolution is substantially lower than both fMRI and ECoG. Whether these downsides would outweigh its high temporal resolution is an empirical question. We will mention the possibility of EEG-tuning in the discussion of the revised paper.

Q1: All experiments are performed using WavLM. Could the authors replicate the main analyses using another pretrained speech or language model to demonstrate that the observed improvements are not specific to this architecture?

We are fine-tuning more speech models and will update this answer once completed.

Q2: The current comparisons do not isolate whether the improvements arise specifically from fMRI-tuning or simply from additional fine-tuning. Could the authors include additional baselines as mentioned above? -The largest encoding performance improvements appear in the auditory cortex. Could the authors explain why this region as benefits most? Could the authors report the SNR of the ECoG data?

Given AC has the highest performance even for the pretrained model, we believe this is an effect of SNR. Electrodes that are more stimulus-driven (in this case, by an auditory stimulus) will be easier to predict. Unfortunately, there is no way to quantify SNR in this dataset because the stimulus was only presented once. (But even in fMRI, areas in AC have the highest SNR in this task.)

We are fine-tuning additional baselines and will update this response once completed.

Q4: Is Figure 3 averaged across participants? The y-axis values appear very small; is this expected?

Yes, Figure 3 is averaged across all fMRI-tuning participants, as well as all ECoG electrodes. The values are small, but correspond to a 1.5% reduction in residual power below the fMRI Nyquist rate, and 0.6% above it.

Paper Formatting Concerns

We will rewrite this section of the introduction, and thank you for catching the missing label in Figure 2C. We will also adjust the phrasing of "fine-tuned encoding models" to "fine-tuned speech models".

Authors · CommentOpenReview ↗

Additional results and clarifications

Q1/W2: All experiments are performed using WavLM. Could the authors replicate the main analyses using another pretrained speech or language model to demonstrate that the observed improvements are not specific to this architecture?

We have additionally fMRI-tuned whisper-large-v3 on the Courtois NeuroMod dataset, and we evaluate its representations on the “Podcast” ECoG dataset. After fMRI-tuning, performance increases from 0.0683 to 0.0702 (2.8% improvement) after averaging across electrodes. This setup differs in several key ways from our original setup. First, the starting model is trained for word recognition instead of a self-supervised objective (WavLM), and is therefore more lexical. Second, the model is simultaneously fine-tuned on multiple fMRI subjects instead of one. Third, the responses in NeuroMod are to audiovisual stimuli rather than purely audio (LeBel et al.). Despite these substantial ablations, the fMRI-tuned Whisper model still improves at predicting ECoG.

Q2a/W3: The current comparisons do not isolate whether the improvements arise specifically from fMRI-tuning or simply from additional fine-tuning. Could the authors include additional baselines as mentioned above?

We fine-tuned additional WavLM models on stimulus-only features: LLaMA hidden states (semantics), wordrate (acoustic), and articulatory features (phonetic). We also fine-tuned models on fMRI responses shuffled in 10-TR blocks to show that the temporal structure in the fMRI responses is necessary. We report the results below:

Model Mean encoding perf. (ρ\rho) SEM
fMRI-tuned 0.08107 0.003183
shuffled-fMRI-tuned 0.07233 0.002976
LLaMA-tuned 0.08822 0.003248
Word rate-tuned 0.08739 0.003228
Articulation-tuned 0.08665 0.003185
Pretrained 0.06955 0.002559

The shuffled-fMRI-tuned models show a small improvement over the pretrained model, but are substantially worse than the normal fMRI-tuned models. The three stimulus-tuned models do perform well, but perhaps for different reasons. First, LLaMA hidden states are a noiseless semantic signal. in contrast with fMRI. Thus, they are a better semantic teacher for the WavLM model. Word rate is a primarily acoustic signal that would be useful for predicting auditory areas, but this speech feature may not be directly represented in the WavLM model. Hence, a small amount of fine-tuning on this signal would improve auditory performance. We believe the same is true for articulatory features.

We also note that the wordrate- and articulation- tuned models needed minimal training before early stopping, only 2 epochs, compared to a minimum 8 for all other models. This further supports the idea that these gains come from the features being simple, noiseless signals, in comparison to the braintuning, which is noisier but also is able to introduce more complex features.

Q3: The fMRI and ECoG datasets contain different stimuli. How semantically or conceptually similar are the two stimulus sets? A simple visualization (e.g., MDS or t-SNE of the stimuli in WavLM embedding space) would help assess the degree of overlap and the generalizability of the proposed approach. Especially, given that each ECoG participant contributes only approximately 30 minutes of data.

While the stimuli in the two datasets are qualitatively similar (they are both natural stories), the two biggest differences are that the fMRI stimuli (Moth Radio Hour) are monologues with noisier audio quality, whereas the ECoG stimulus (This American Life) is a dialogue with clean audio. Because the ECoG stimulus is only a single story (whereas the fMRI has ~100 stories), it spans a much smaller semantic space.

We evaluated the degree of overlap of the fMRI and ECoG stimuli by computing the Wasserstein distance of their WavLM embeddings from the pretrained model. We first reduced the features to 50 PCs for computational reasons. The Wasserstein distance between the two sets of stimuli was 7.634, and this was larger than two within-dataset controls. The distance between two stories from the fMRI dataset was on average 5.957, and the distance between the first and second halves of the ECoG stimulus was 5.280. These suggest that the stimuli do occupy distinct parts of the latent space.

Since we are not allowed to give links, we cannot provide any visualizations of the latent space. With t-SNE, the distribution of the stimuli appears to be mostly disjoint. We will include plots that show the projected latent space in the final manuscript.

Authors · CommentOpenReview ↗

We additionally wanted to contextualize our answer to Q4:

Q4: Is Figure 3 averaged across participants? The y-axis values appear very small; is this expected?

Yes, Figure 3 is averaged across all fMRI-tuning participants, as well as all ECoG electrodes. The values are small, but correspond to a 1.5% reduction in residual power below the fMRI Nyquist rate, and 0.6% above it. We note that this is a 1.5% reduction in total residual power, which includes a dominant term of unexplainable but difficult to estimate noise power. For fMRI, noise power is easily over half of the total signal. This is a conservative estimate when compared to faster ECoG, so in comparison this 1.5% reduction is closer to at least a 3-5% reduction in the unexplained-but-explainable residual power.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…