PathNavigate: A Training-Free Pathology Agent with Surprise-Guided Scan and Shared Slide Memory for Whole-Slide VQA
Chunze Yang, Qidong Liu, Wenjie Zhao, Yue Tang, Jiusong Ge, Di Zhang, Jiashuai Liu, wu lei, Junbo Lu, Ni Zhang, Xian Wu, Zeyu Gao, Chen Li
TL;DR. A training-free WSI-VQA framework that utilizes a shared online memory substrate to enable surprise-guided navigation and unified slide-level reasoning.
Abstract. Whole-slide image visual question answering (WSI-VQA) frames pathology as an extreme-context search problem: to answer a free-form clinical query, a system must first navigate a gigapixel slide under a strict inspection budget to locate sparse, high-resolution evidence. Existing approaches largely fall into two paradigms: i) supervised pathology multimodal large language models (MLLMs) and agents can absorb localization and reasoning into learned modules, but they often couple navigation to task-specific supervision and retraining, limiting their practicality; ii) training-free pathology agents avoid this cost by keeping core models frozen, but often follow a question-first design, i.e. constructing the initial candidate set mainly from query-conditioned relevance. This can miss decisive morphology that is not named in the question, and force heavier inference-time scaffolding. To address this challenge, we introduce PathNavigate, a training-free pathology agent built around a scan-search-readout routine. Before question matching, PathNavigate scans the current slide at low magnification with a shared online memory module over frozen pathology features, producing a slide-specific surprise field that marks an abnormal-region pool. It then applies question-conditioned PLIP relevance only within this pool to select high-magnification search targets. Finally, it extracts local high-magnification evidence and answers with a frozen perceptor-adjudicator stack, using the same online memory as slide-level context. Experiments on WSI-VQA and SlideBench-BCNB show that the proposed scan-search-readout design improves answer accuracy and yields more interpretable evidence-selection trajectories with higher efficiency. To ease reproducibility, we have released the code online.
From the authors: Di Zhang · edit · also an author?
Nothing yet.
edit · history
NeurIPS 2026
Accept (poster) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:44 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The paper presents PathNavigate, an interesting training-free framework designed based on a pathologist-inspired scan-search-readout workflow. The ablation studies effectively validate the contributions of the components. Reviewers noted various comments including whether the framework's gains and generality are sufficiently established. It's also good to present a clearer comparison with PathAgent and related approaches, quantitative measures that surprise scores identify diagnostically meaningful regions, and more rigorous evaluation of the large open-ended performance gains. In addition, the framework's dependence on particular pretrained models and several key search parameters should be further analyzed, and method descriptions can be improved with concrete examples.
Final justification
The rebuttal has provided more result evaluations as requested by the reviewers. All reviewers have maintained their positive ratings and are leaning towards an acceptance.
Read meta-review
Meta-review
The paper presents PathNavigate, an interesting training-free framework designed based on a pathologist-inspired scan-search-readout workflow. The ablation studies effectively validate the contributions of the components. Reviewers noted various comments including whether the framework's gains and generality are sufficiently established. It's also good to present a clearer comparison with PathAgent and related approaches, quantitative measures that surprise scores identify diagnostically meaningful regions, and more rigorous evaluation of the large open-ended performance gains. In addition, the framework's dependence on particular pretrained models and several key search parameters should be further analyzed, and method descriptions can be improved with concrete examples.
Final justification
The rebuttal has provided more result evaluations as requested by the reviewers. All reviewers have maintained their positive ratings and are leaning towards an acceptance.
2 comments
General Response to the Area Chair
We are deeply grateful to the Area Chair for the careful assessment of our submission and for synthesizing the central issues raised during the review process.
In response to the reviewers’ comments and the concerns highlighted in the meta-review, we have provided detailed point-by-point clarifications and substantial additional evidence. In particular, we conducted supplementary experiments on model generality, surprise-based localization, traversal-order sensitivity, search-budget selection, semantic evaluation of open-ended answers, and comparisons with PathAgent and additional slide-level foundation models. We have also clarified the method configuration, evaluation protocols, and the scope and limitations of our claims.
We hope that these new results and clarifications provide a more complete basis for evaluating the contribution, reliability, and general applicability of PathNavigate. We respectfully ask the Area Chair to take this additional evidence into consideration in the final assessment, and we sincerely appreciate the time and effort devoted to evaluating our work.
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes a WSI-VQA which first scans the low resolution image by utilizing previous memory similar to a pathologist and do the search within a compact candidate set and generate the answer.
Strengths and weaknesses
The proposed approach composed of 4 parts: Shared online memory, surprise-driven exploration, task-conditioned retrieval, evidence readout and QA. While each of the components used in the proposed framework has been studied in the broader QA/retrieval literature such as shared online memory in multi-turn search agents (https://arxiv.org/pdf/2604.04503), surprise-driven exploration in curiosity-based RL (https://arxiv.org/pdf/2308.04836), task-conditioned retrieval in knowledge-based VQA, and evidence readout/QandA in medical QA (https://arxiv.org/abs/2506.10751), to my knowledge, their integration into a unified framework for WSI QA has not been explored.
To better state the contribution, a more detailed architectural and empirical comparison with PathAgent should be given, examining differences in design, and better quantitative evaluation across all reported metrics.
Questions
To better state the contribution, a more detailed architectural and empirical comparison with PathAgent should be given, examining differences in design, and better quantitative evaluation across all reported metrics.
Limitations
Yes
Final justification
I have reconsidered the paper in light of the reviews and the authors' rebuttal, and I have decided to maintain my original rating.
Formatting concerns
2 comments
Rebuttal
Reviewer 9jWg
We thank the reviewer for recognizing that, although the individual components have precedents in broader QA and retrieval research, their integration into a unified WSI-QA framework has not been sufficiently explored.
Comment / Question — A fuller architectural and empirical comparison with PathAgent
Comment / Question. To state the contribution more clearly, the paper should provide a more detailed architectural comparison with PathAgent and a better quantitative comparison across all reported metrics.
Response. We appreciate this constructive request. Our contribution is the WSI-specific organization of these components into a Scan–Search–Readout controller, rather than a claim that each component is individually new. PathNavigate first builds a persistent slide-level online state and question-independent surprise pool, introduces question relevance only within that pool, and performs bounded high-magnification evidence readout. By contrast, the recoverable PathAgent implementation starts independently from each question and uses question-patch relevance from the initial retrieval step.
| Architectural dimension | PathNavigate | PathAgent (recoverable implementation) |
|---|---|---|
| Whole-slide state | Online scan state shared across questions on a WSI | Each question starts independently |
| Initial candidates | Question-independent surprise proposal | Question-patch relevance retrieval |
| When the question enters | After proposal, for reranking and routing | From initial retrieval |
| Later acquisition | Bounded 20× local readout | Multi-round retrieval based on missing information |
| Main focus | Slide state, proposal, and budget control | Question-driven iterative retrieval |
We summarize the standard metrics and the additional semantic adjudication on the fixed 80 common open-ended questions in one table:
| Metric | PathNavigate | PathAgent historical outputs |
|---|---|---|
| Overall accuracy | 56.34% | 33.88% |
| MCQ accuracy | 52.21% | 51.54% |
| Open-ended accuracy | 61.00% | 13.91% |
| BLEU-1 | 60.92 | 42.73 |
| ROUGE-L | 63.53 | 33.54 |
| Qwen3.5-9B strict semantic correctness (80 questions) | 60/80 (75.00%) | 12/80 (15.00%) |
| Qwen3.5-9B correct or partially correct | 61/80 (76.25%) | 22/80 (27.50%) |
| Qwen3.5-9B pairwise preference | 54 wins / 25 ties / 1 loss | 1 win / 25 ties / 54 losses |
For the semantic evaluation, we used 80 common open-ended questions with saved predictions from both methods, anonymized the method identities, randomly swapped the A/B order, and provided Qwen3.5-9B with the question, reference answer, and both predictions. The judge assigned correct/partially correct/incorrect labels and a pairwise preference. These results provide semantic evidence beyond surface matching, while remaining an automated single-judge evaluation. We also emphasize the comparison boundary: the historical outputs are not fully matched in question denominator, model stack, RAG/prior, search budget, or original open-ended scoring, and identical latency/token/visual-call fields cannot be recovered. The comparison is therefore not presented as a same-model, same-budget causal study. In the revision, we will add the architecture matrix to the related-method discussion, place the full metric-and-judge table next to Table 2, describe the Qwen3.5-9B protocol, and explicitly state these protocol boundaries.
Dear Reviewer,
Thank you once again for your careful assessment of our work and for the insightful feedback you provided. We have taken your comments seriously and have provided detailed responses, including additional comparisons and analyses where appropriate. We hope these responses make the contributions and empirical evidence of our work clearer.
As the discussion phase is nearing its conclusion, we would welcome any further comments or questions. We would be glad to clarify any remaining points and sincerely appreciate your continued consideration of our paper.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper introduces PathNavigate, a training-free agent for answering questions about whole-slide pathology images. Instead of directly searching for regions that match the question, the method first uses a memory module to learn what is typical within the current slide and assigns each patch a surprise score based on how much it differs from that learned context. Regions with high surprise scores are treated as potentially important and are then refined using question relevance before being examined at higher magnification. The experiments show that this scan-first strategy helps the model find better diagnostic evidence and improves whole-slide VQA performance.
Strengths and weaknesses
Strengths
- The motivation is clear and well grounded in the limitations of prior work. Existing training-free WSI-VQA methods often begin with query-driven visual search, which can miss diagnostically important regions that are not explicitly mentioned in the question. The proposed scan-first design is more aligned with how pathologists typically inspect slides: first forming a broad impression of the tissue, and only then focusing on question-relevant findings.
- The use of test-time memory for spatial ROI proposal is a modest but meaningful methodological contribution. Since the memory is reinitialized for each slide and ROI candidates are selected based on relative surprise within that slide, the method does not require learning a dataset-specific distribution. This makes the approach naturally compatible with the training-free setting and potentially transferable across datasets.
Weaknesses
- Although the per-slide surprise score is appealing and dataset-independent, it is not clear that it consistently corresponds to pathologically meaningful regions. By construction, surprise may also highlight artifacts such as folds, pen marks, staining variation, or other visually atypical but diagnostically irrelevant regions. Since the paper emphasizes interpretability and pathologist-like scanning, it would be valuable to provide quantitative evidence, ideally using region-level annotations, that the surprise field aligns with diagnostically relevant tissue rather than merely statistical outliers.
- The large open-ended gain over PathAgent in Table 2 is not fully convincing. While the open-ended accuracy gap is very large, the multiple-choice gains on WSI-VQA and BCNB are much smaller under a similar stack. This raises the question of whether the open-ended improvement reflects better navigation or is partly due to the evaluation protocol. In particular, PathAgent obtains a low open-ended accuracy despite a relatively high BLEU-1 score, suggesting that semantically reasonable answers may be penalized by surface-level matching. The comparison would be more convincing if the authors re-evaluated open-ended answers using a semantic metric, such as an LLM-based judge.
- The online memory update appears to be sensitive to patch traversal order. Since the threshold () is estimated from the first () patches and then kept fixed, different scan orders or different tumor locations could change the calibration of the surprise scores. In addition, the memory continues to adapt after the threshold is set, which may introduce a mismatch between the fixed threshold and the evolving memory state.
Questions
-
As mentioned in weaknesses, the proposed online memory update appears to be order-dependent: different patch traversal orders could lead to different memory states and ultimately different surprise scores. Have the authors evaluated the sensitivity of the method to traversal order? If not, a discussion of whether this effect is significant in practice would strengthen the paper.
-
The routing and memory hyperparameters in Table 6 appear to be manually selected heuristic settings. It would be helpful to clarify whether these values were tuned on a validation set, chosen from prior work, or selected empirically.
-
The proposed surprise score is based on the pre-update gradient norm of an online reconstruction memory. However, it is unclear how much this differs in practice from simpler feature-space anomaly scores, such as the distance between a patch feature and the slide-level average feature. A comparison with mean-feature deviation would help clarify whether the online memory mechanism provides benefits beyond simple feature analysis.
Limitations
Yes
Final justification
After considering the authors’ rebuttal together with the other reviewers’ comments, I retain my original rating.
Formatting concerns
NA
2 comments
Rebuttal
Reviewer VNYS
We thank the reviewer for the careful questions about the pathological meaning of surprise, open-ended evaluation, and traversal-order sensitivity. We follow the review’s three weaknesses and three questions below.
Weakness 1 — Surprise may highlight statistical outliers rather than meaningful pathology
Weakness. It is unclear whether surprise consistently identifies pathologically meaningful tissue rather than folds, pen marks, staining variation, or other visually atypical artifacts; region-level quantitative evidence would be valuable.
Response. We appreciate this central interpretability concern. Surprise should be interpreted as a slide-relative proposal signal, not as a lesion probability or segmentation output. We evaluated it on CAMELYON16, which provides lesion masks. The 96 slides were source-stratified into 48 development and 48 held-out slides; only held-out results are reported below.
| CAMELYON16 held-out split | Value |
|---|---|
| ROC-AUC | 0.5371 |
| AP | 0.1985 |
| Precision@10 | 0.1792 |
| Recall@10 | 0.0520 |
| Hit@10 | 0.4583 |
The top-ranked surprise candidates show limited but measurable lesion enrichment, while the near-random AUC cautions against treating surprise as a localization model. Across all 96 slides, increasing candidates from 10 to 100 raises lesion recall from 0.0410 to 0.3662 and Hit@K from 0.3542 to 0.6979. Within PathNavigate, surprise supplies broad question-independent candidates; the subsequent PLIP reranking uses the question to prioritize regions relevant to the requested morphology and reduce the rank of irrelevant outliers. In the revision, we will add this region-level analysis to the experiments and explicitly describe surprise as a proposal prior followed by question-conditioned refinement, rather than as a lesion detector.
Weakness 2 — The open-ended gain may reflect lexical evaluation bias
Weakness. The much larger open-ended gain over PathAgent, together with PathAgent’s relatively high BLEU-1, raises the possibility that surface matching penalizes semantically reasonable answers; an LLM-based semantic evaluation would strengthen the comparison.
Response. We thank the reviewer for this insightful evaluation suggestion. The open-ended advantage remains large under an anonymized semantic judge and is therefore not explained solely by substring matching. We fixed 80 open-ended questions for which both methods had stored predictions. Method identities were removed, A/B order was randomized per question, and Qwen3.5-9B received the question, reference, and both predictions under one fixed rubric. It labeled each answer correct, partially correct, or incorrect and produced a pairwise preference; all 80 outputs parsed successfully.
| Fixed 80 open-ended questions | PathNavigate | PathAgent |
|---|---|---|
| Strictly correct | 60/80 (75.00%) | 12/80 (15.00%) |
| Correct or partially correct | 61/80 (76.25%) | 22/80 (27.50%) |
| Pairwise outcome from PathNavigate’s view | 54 wins / 25 ties / 1 loss | — |
These results support a semantic improvement beyond lexical scoring. We nevertheless treat this as auxiliary evidence because a single automated judge may have model-specific preferences and cannot replace double-blind pathology-expert evaluation. In the revision, we will add the sampling, anonymization, order randomization, judging rubric, and results after Table 2, and state the single-judge limitation explicitly.
Weakness 3 — Online memory and the fixed threshold may be traversal-order sensitive
Weakness. The threshold is estimated from the first 100 patches and then fixed while memory continues to update, so different traversal orders may change surprise calibration and ROI selection.
Response. We appreciate the reviewer for identifying this property. The proposal stage is indeed order-sensitive, although the downstream effect on final answers is small. On identical feature caches from 60 fixed WSIs, we changed only the traversal order and compared the resulting surprise ranking and Top-30 ROIs.
| Relative to raster | Mean Spearman | Top-30 Jaccard |
|---|---|---|
| reverse-raster | -0.419 | 0.208 |
| column-major | 0.309 | 0.356 |
| serpentine | 0.996 | 0.778 |
| mean of five fixed random orders | 0.267 | 0.250 |
Thus, different scan orders can produce different proposal rankings; serpentine is closest to raster because it preserves similar local adjacency. The end-to-end experiment in Q1 shows that this variation does not significantly change answer accuracy under the current reranking and 20× verification pipeline. In the revision, we will report this proposal-level sensitivity, specify raster order and the 100-patch warm-up as fixed inference conditions, and include order dependence in the Limitations section.
Question 1 — Does traversal order affect final task performance?
Question. Have the authors evaluated whether different traversal orders significantly affect final-answer accuracy in practice?
Response. Thank you for prompting the end-to-end check. In our controlled experiment, traversal order changes proposals but does not significantly change final-answer accuracy. We used 100 pre-fixed questions that all entered the image-evidence pipeline. CONCH 5×/20× features, PLIP, RAG, the 15-call limit, random seed, and all other settings were held constant; only the 5× traversal order changed.
| Traversal order | Overall | MCQ | Open-ended | Mean visual calls |
|---|---|---|---|---|
| raster | 44/100 (44.00%) | 28/72 | 16/28 | 12.89 |
| reverse-raster | 48/100 (48.00%) | 32/72 | 16/28 | 13.26 |
| fixed-random | 44/100 (44.00%) | 28/72 | 16/28 | 14.07 |
The paired p-values relative to raster are 0.5034 and 1.0000. Accuracy differs by only 0–4 points, with neither comparison significant, suggesting that reranking and 20× verification buffer much of the proposal variation. This does not imply strict order invariance, but it indicates a small practical effect in the evaluated setting. In the revision, we will add this controlled study to the robustness experiments and use raster as the explicitly documented default order.
Question 2 — How were the hyperparameters selected?
Question. Were the routing and memory hyperparameters in Table 6 tuned on a validation set, inherited from prior work, or selected empirically?
Response. We thank the reviewer for requesting this clarification. The online-memory formulation follows Titans, while the task-specific numerical hyperparameters were selected on the validation set. Specifically, the neural memory that is updated at test time and the use of the pre-update gradient norm as a surprise signal follow the Titans formulation; the 768-dimensional width is determined by the CONCH v1.5 feature dimension. We selected the remaining numerical settings—including memory depth, warm-up length, learning rate, threshold scale, proposal-pool size, NMS, type-specific ROI budgets, spacing rules, PLIP weight, patches per ROI, and the visual-call cap—from predefined candidates using validation accuracy together with proposal coverage and inference efficiency. No test questions were used for hyperparameter selection, and we do not claim that these values are globally optimal.
| Source | Parameters |
|---|---|
| Followed from Titans | Online neural memory; test-time gradient update; pre-update gradient-norm surprise |
| Encoder-determined | 768-d input/hidden width |
| Validation-selected | 2 layers; 100 warm-up patches; LR 0.05; threshold scale 1.0; pool 30; NMS 3; ROI budgets 10/12/13; spacing rules; PLIP weight 0.5; ≤2 patches per ROI; ≤15 calls per question |
In the revision, we will replace the ambiguous statement in Implementation Details with this source-by-source account and explicitly state that all task-specific numerical settings were selected on the validation split.
Question 3 — How does online surprise differ from mean-feature deviation?
Question. How different is the pre-update gradient-norm surprise score from a simpler anomaly score such as distance to the slide-level mean, and does it provide additional benefit?
Response. We thank the reviewer for suggesting this strong deterministic baseline. Online surprise produces substantially different proposals and higher task accuracy than slide-mean deviation. We compute the cosine distance from each patch feature to the mean feature of its WSI. At the proposal level, its mean Spearman correlation with Yaad is 0.014 and the Top-30 Jaccard is 0.094, showing that the two scores rank and select different regions.
| All 726 evaluable questions | PathNavigate | Mean-distance baseline | Difference |
|---|---|---|---|
| Overall | 409/726 (56.34%) | 382/726 (52.62%) | +3.72 pp |
| MCQ | 201/385 (52.21%) | 187/385 (48.57%) | +3.64 pp |
| Open-ended | 208/341 (61.00%) | 195/341 (57.18%) | +3.82 pp |
Mean distance itself exceeds Random ROI (49.50%), confirming that it is informative; PathNavigate improves a further 3.72 points on the same question set. In the revision, we will add the proposal-overlap statistics and the full 726-question mean-distance baseline to the ablation section.
Dear Reviewer,
We sincerely appreciate your thoughtful review and valuable suggestions. Your comments have been very helpful in identifying aspects of the paper that required further explanation and validation. We have responded to each concern in detail and hope that the additional analyses and clarifications adequately address your questions.
With the discussion period closing soon, we would greatly appreciate hearing your thoughts on our response. We remain available to clarify any outstanding concerns or provide further details if needed.
- Rating
- 5/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 4/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors present PathNavigate, a training-free pathology AI agent that operates with the principles of scan-search-readout. This is not meant to be a retraining of existing MLLMS, but rather how to operationalize them to increase the downstream performance, as well as efficiency, without having to extensively explore high magnification patches. The authors evaluate on several datasets PathMMU, SlideBench-BCNB, and WSI-VQA and show PathNavigate is able to outperform other baselines.
Strengths and weaknesses
The work is clearly-written, with detailed and logical explanations behind each step and why each step is required. The fact that this emulates the pathologist’s diagnostic workflow is interesting – Several works have tried to model pathologist’s workflow (most notably ZoomMIL), but this presents a refreshing and welcoming angle. The fact that this doesn’t require another MLLM finetuning, but rather smart organization of existing models (CONCHv1.5, Patho-R1, etc), is encouraging. The detailed ablation analyses (especially Table 3), helps us understand that indeed each of the component play an important role.
However, there are several weaknesses that I would like the author to address, so it gets more appreciated by the field. I am willing to adjust the scores once these questions are answered.
-
I would like to think PathNavigate as a framework, that is not necessarily attached to a specific set of chosen models. If possible, the authors should show that this works with other choice of models (e.g., UNI2 or Virchow2 instead of CONCHv1.5 for vision encoder, and CONCH or Musk instead of PLIP). I am especially curious why the users opted for PLIP, which is considered outdated compared to CONCH or MUSK in terms of vision-language pathology model.
-
The paper is well-written, but it does feel technically dense, especially for the part where PathNavigate mechanism is explained. For each of 3.1, 3.2, 3.3, it would be great if the authors can augment the explanation with concrete pathology and/or diagnostic workflow examples.
-
While well written, the key parameters to the model seem not to be mentioned. For instance, It is rather unclear what magnifications were used. 5x for low? 20x for high? It may be subtly mentioned in the manuscript, but it wasn’t apparent at all. How many ROIs are selected for ROI-pool? Please make these parameters exposed clearly to the readers.
-
It is slightly unclear what the role of PLIP relevance is. The authors state that it re-ranks ROIs within the ROI pool. How many ROIs out of ROI pool are “selected” for high magnification? Specifying these quantities explicitly helps emphasize the importance of PLIP relevance and better understand what is going on in Table 3 ablation (w/o PLIP).
-
How is PathNavigate expected to work for cases, where the low magnification scanning likely misses important diagnostic cues due to downsampling? In this case, the surprise signal would be relatively homogeneous – Would the PathNavigate in this case dynamically adjust the size of ROI pool and explore more in high-magnification? I believe some device to ensure that PathNavigate spends more budget in case of homogenous surprise scores are needed.
-
The agentic work like this will benefit from displaying more examples of how PathNavigate works on some of the benchmark questions (Figure 4). There is only one example throughout the entire manuscript. I encourage the authors to populate the supplemental with more examples.
-
In baselines, TITAN is a vision-language slide foundation model. How are the authors using the model? Is it zero-shot where each question from MCQ are embedded with text encoder and the closest one to the slide embedding is retrieved? If so, the authors need to make this evaluation explicit, as it might be confusing to readers who are used to TITAN more as a vision encoder. Also, I would encourage the authors to include PRISM.
-
Line 164~165 is slightly confusing. I thought ROI selection had nothing to do with the question prompt (the question gets introduced in task-conditioned search).
-
In line 129 of the manuscript, the authors mention CONCH is d=768. CONCH itself is d=512, so I think the authors were referring to CONCHv1.5, which is d=512.
Questions
Asked above
Limitations
This part feels missing from the paper.
Final justification
I appreciate the thoughtful response to my criticisms and questions, I am increasing my score.
Formatting concerns
no concerns
2 comments
Rebuttal
Reviewer xzTa
We appreciate the reviewer’s valuable time and insightful suggestions, which are important to our paper. We deliver the point-by-point response as follows.
Weakness 1 — Model replaceability and the choice of PLIP
Weakness. PathNavigate should function as a framework rather than being tied to CONCH v1.5 and PLIP; the reviewer also asks why PLIP was chosen over newer pathology VLMs.
Response. We appreciate this important suggestion. PathNavigate is not structurally tied to one visual encoder or reranker: low-magnification encoding, online surprise, question-conditioned reranking, and high-magnification readout are separate interfaces. We replaced CONCH v1.5 with UNI2-h on all 726 questions while fixing PLIP, navigation budget, language services, seed, and the 100 WSIs used for the matching RAG index.
| Encoder | Overall | MCQ | Open-ended |
|---|---|---|---|
| CONCH v1.5 | 56.34% | 52.21% | 61.00% |
| UNI2-h | 56.61% | 51.69% | 62.17% |
The 0.28-point difference supports encoder interchangeability. We initially adopted PLIP following PathAgent's question-conditioned retrieval workflow. In PathNavigate, PLIP is restricted to lightweight within-pool reranking after question-independent surprise proposal; it is not the whole-slide proposal mechanism. Full, w/o-PLIP, and PLIP-only accuracy is 56.34%, 53.42%, and 52.20%, respectively. Controlled MUSK/CONCH reranker replacements are ongoing. **In the revision, Sec. 3 will clarify the modular interfaces and the PathAgent-motivated choice of PLIP; the experiments will add UNI2-h and, if completed before the deadline, the controlled MUSK/CONCH results.
Weakness 2 — The method is technically dense and lacks a concrete workflow example
Weakness. Sections 3.1–3.3 would benefit from concrete pathology or diagnostic-workflow examples connecting the three stages.
Response. We thank the reviewer for this helpful presentation suggestion. We agree that the end-to-end interaction should be more explicit. For a question about invasive adenocarcinoma, Scan identifies slide-relative atypical regions at 5×; Search preserves spatial coverage and prioritizes candidates related to irregular glands, invasion, and stromal reaction; Readout inspects the top ROIs at 20× to confirm architecture, atypia, and tumor-stroma relations. This illustrates why discovery precedes question matching and 20× is used for confirmation. In the revision, we will add this running example and concise transitions across Secs. 3.1–3.3.
Weakness 3 — Key magnifications and ROI parameters are not sufficiently exposed
Weakness. The low/high magnifications and ROI-pool size are unclear.
Response. Thank you for identifying this omission. We use 5× for whole-slide scanning, 20× for local readout, and an initial pool of at most 30 ROIs. The online memory is a 2-layer 768-d GELU MLP with 100 warm-up patches, LR 0.05, and threshold scale 1.0. NMS window is 3; general/morphology/clinical questions plan 10/12/13 ROIs; each ROI contributes at most two patches; each question has at most 15 visual calls; PLIP weight is 0.5; reflection is disabled and seed is 42. In the revision, we will consolidate these settings in the implementation-details subsection and cross-reference them from the method.
Weakness 4 — The role of PLIP relevance and the number of high-magnification ROIs are unclear
Weakness. It is unclear how PLIP reranks the ROI pool and how many ROIs are selected for high-magnification inspection.
Response. We appreciate the request for a clearer accounting. PLIP only reranks the surprise-generated pool; it does not initiate another whole-slide search. Surprise proposes up to 30 ROIs at 5×. PLIP computes question-region relevance within this pool, after which general/morphology/clinical questions plan 10/12/13 targets. Each target contributes at most two 20× patches, while the full question is capped at 15 visual calls and may stop earlier. Thus, candidate-pool size, planned targets, and actual high-magnification calls are different quantities. In the revision, we will make this distinction explicit in Secs. 3.2–3.3 and the implementation table.
Weakness 5 — Homogeneous surprise may require a larger exploration budget
Weakness. If low-magnification scanning misses fine cues and surprise is homogeneous, PathNavigate may need to enlarge the ROI pool and high-magnification budget.
Response. This is an important concern. The submitted system deliberately uses a fixed budget rather than automatic expansion. During development, we compared several budgets and retained 30/10/15 for its accuracy-efficiency trade-off; limited gains from larger budgets did not justify automatic expansion by default. We then fixed 100 low-surprise-variance morphology questions and changed only candidate pool/planned ROIs/maximum calls from 30/10/15 to 60/20/25; all features, PLIP, RAG, seed, and answer settings were identical.
| Budget | Accuracy | Calls | Time | 20× scan amount |
|---|---|---|---|---|
| 30/10/15 | 62.00% | 14.42 | 119.8 s | 396.9 |
| 60/20/25 | 64.00% | 21.50 | 165.1 s | 637.8 |
Paired outcomes were 59/3/5/33 (both/default-only/expanded-only/both wrong; p=0.7266). Thus, the nonsignificant +2 points cost +49.1% calls, +37.8% time, and +60.7% 20× scanning, supporting the fixed default while confirming the limitation. In the revision, we will add this result after the efficiency analysis, explain the fixed budget in Sec. 3.3, and list adaptive expansion as future work.
Weakness 6 — Too few qualitative trajectories
Weakness. The manuscript contains only one complete example; more benchmark trajectories would help readers understand the agent.
Response. We agree that one trajectory is insufficient. Additional cases are needed to show both representative successes and failures. We will show the WSI overview, 5× surprise, candidate ROIs, PLIP reranking, 20× evidence, and answer for correct, incorrect, artifact-triggered, and homogeneous-surprise cases. In the revision, we will expand the supplementary qualitative section with these trajectories and reference them from the main text.
Weakness 7 — TITAN protocol is unclear and PRISM is missing
Weakness. The manuscript should explain how TITAN answers MCQs and include PRISM.
Response. Thank you for requesting a clearer baseline protocol. TITAN is evaluated through its official zero-shot slide interface, and PRISM is added on the same 385 MCQs. TITAN aggregates all 20× CONCH v1.5 patch features and coordinates into a reusable slide embedding. Each option is encoded with four fixed pathology templates, and the highest slide-text probability is selected. This choice-only protocol does not use the question or our agent components. PRISM aggregates all non-overlapping 20× 224×224 Virchow V1 features from HEST tissue regions, without top-k sampling, under the same templates.
| Model / protocol | Accuracy |
|---|---|
| TITAN, choice-only, four templates | 33.77% |
| PRISM, choice-only, four templates | 33.77% |
| TITAN, question-aware, one template | 30.91% |
| PRISM, question-aware, one / four templates | 32.73% / 30.91% |
Each model uniquely answers 65 questions correctly (36.62% agreement; paired p=1.0), showing equal aggregate accuracy but complementary predictions. In the revision, we will specify TITAN’s inference protocol in the baseline subsection and add PRISM and the sensitivity results to the baseline table.
Weakness 8 — The timing of ROI proposal and question input is confusing
Weakness. Lines 164–165 are confusing because ROI selection appears independent of the question, whereas the method is described as task-conditioned search.
Response. We apologize for the ambiguous wording. The reviewer is correct: the question does not participate in surprise proposal. We first compute 5× surprise from slide content, form a question-independent candidate pool, then use question type and PLIP for routing and within-pool reranking before 20× readout. “Task-conditioned” therefore refers to the post-proposal routing, ranking, and readout—not whole-slide candidate generation. In the revision, we will rewrite Lines 164–165 and Sec. 3 to explicitly distinguish question-independent proposal from question-conditioned reranking/readout.
Weakness 9 — CONCH version and feature dimension are imprecisely stated
Weakness. The manuscript states that CONCH is 768-dimensional, whereas the original CONCH is 512-dimensional; the exact version should be clarified.
Response. Thank you for catching this imprecise naming. Our experiments use the CONCH v1.5 checkpoint through TRIDENT’s conch_v15 extractor, producing 768-d features at both 5× and 20×. Shortening the name to “CONCH” can reasonably be read as the earlier 512-d model, and we apologize for the ambiguity. In the revision, we will consistently write “768-d CONCH v1.5 (conch_v15) patch features” and add the formal checkpoint/extractor citation.
Limitations
Limitation. The limitations discussion is missing.
Response. We agree and apologize for the missing dedicated section. Key limitations are: fine diagnostic cues may be invisible at 5×; artifacts may receive high surprise; proposals depend on traversal order and the 100-patch warm-up; the budget does not expand automatically; larger 20× budgets increase cost; and results depend on frozen encoders, rerankers, and the answer stack. Encoder replacement is supported, but alternative rerankers are not yet controlled. PathNavigate is a research system, not a clinical diagnostic tool. In the revision, we will add a dedicated Limitations section and connect these points to the corresponding experiments and future directions.
Dear Reviewer,
Thank you again for the time and effort you have devoted to reviewing our paper. We greatly appreciate your constructive comments, which have helped us improve both the presentation and evaluation of our work. We have carefully addressed the concerns raised in your review and hope that our responses have clarified the main points.
As the discussion period is approaching its end, we would be grateful for any further feedback you may have. Please feel free to let us know if any issue remains unclear, and we will be happy to provide additional clarification.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Response to the Area Chair
We sincerely thank the Area Chair for the careful and encouraging meta-review. We are particularly grateful for the positive assessment of PathNavigate as an interesting training-free realization of the pathologist-inspired Scan–Search–Readout workflow and for recognizing that our ablations validate the contributions of its components. We address each additional suggestion in the corresponding reviewer responses, as summarized below.
We appreciate the suggestion to further establish the framework's gains and generality. In Reviewer xzTa, Weakness 1, replacing CONCH v1.5 with UNI2-h under the same configuration yields 56.61% versus 56.34% accuracy on all 726 questions, showing that PathNavigate is not tied to one pathology encoder. Reviewer xzTa, Weakness 5 and Reviewer VNYS, Weakness 3 / Question 1 further examine search budgets and traversal orders, showing an accuracy–efficiency trade-off and only small, statistically insignificant changes in final-answer accuracy across scan orders. We will add these results and clearly state the generality and robustness supported by the current experiments.
We thank the AC for emphasizing this comparison. In Reviewer 9jWg, Comment/Question, we clarify that PathNavigate first forms a slide-level, question-independent surprise pool and then applies question-conditioned reranking, whereas PathAgent is question-driven from initial retrieval. We also report overall accuracy, MCQ, open-ended accuracy, BLEU-1, ROUGE-L, and semantic adjudication: MCQ performance is similar, while PathNavigate is stronger on the overall, open-ended, and semantic results. We will clarify these workflow differences in the paper and add the fixed-80-question Qwen3.5-9B judging protocol and results to the appendix, together with the comparison boundaries.
We appreciate this insightful suggestion. Reviewer VNYS, Weakness 1 evaluates surprise on an independent CAMELYON16 split with lesion masks. Top-ranked proposals show measurable lesion enrichment, including a Hit@10 of 0.4583, while broader candidate coverage improves lesion recall and slide-level hit rate. Thus, surprise serves as a useful question-independent proposal prior rather than a lesion-segmentation score; subsequent question-conditioned PLIP reranking further focuses the candidates. We will add this regional evaluation and its scoped interpretation to the experimental analysis.
We are grateful for the AC's emphasis on evaluation rigor. In Reviewer VNYS, Weakness 2, also summarized in Reviewer 9jWg, Comment/Question, we evaluate 80 fixed open-ended questions with predictions from both methods. Method identities are hidden, A/B order is randomized, and Qwen3.5-9B judges the question, reference answer, and both predictions. PathNavigate achieves 75.00% strict semantic correctness versus 15.00% for PathAgent, with 54 wins, 25 ties, and 1 loss. This supports that the gain is not solely due to surface matching. We will provide the full protocol and results in the appendix and note the limitation of a single automated judge.
We thank the AC for encouraging a transparent analysis. Reviewer xzTa, Weakness 1 addresses encoder replacement and PLIP's role; Weaknesses 3–5 specify magnifications, candidate and ROI budgets, visual-call limits, and budget sensitivity; and Reviewer VNYS, Question 2 distinguishes the online-memory configuration inherited from Titans from the remaining parameters selected on the validation set. We will consolidate parameter values, sources, and sensitivity results to make the inference configuration explicit and reproducible.
We fully agree that concrete examples will improve accessibility. Reviewer xzTa, Weakness 2 provides a continuous example spanning 5× scanning, surprise proposal, question-conditioned reranking, and 20× evidence readout; Weakness 6 addresses additional successful, failed, artifact-triggered, and homogeneous-surprise trajectories; and Weakness 8 clarifies when the question enters the pipeline. We will integrate the example into Secs. 3.1–3.3, clarify the stage transitions, and add further trajectories to the supplementary material.