potentialpaper

NeuroRVQ: Multi-Scale Biosignal Tokenization for Generative Foundation Models

Konstantinos Barmpas, Na Lee, Dimitrios Halatsis, William Raftery, Yannis Panagakis, Dimitrios Adamos, Nikolaos Laskaris, Alexandros Koliousis, Dario Farina, Stefanos Zafeiriou

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

Abstract. Biosignals such as electroencephalography (EEG), electrocardiography (ECG), and electromyography (EMG) encode physiological activity across multiple temporal and spectral scales, yielding representations that are rich but challenging for machine learning. Foundation models trained to predict masked signal tokens have shown promise in learning generalizable biosignal representations, yet their performance depends on the tokenizer's ability to preserve high-frequency dynamics and reconstruct signals with high fidelity. We introduce NeuroRVQ, a modality-adaptive biosignal tokenizer family designed for high-fidelity signal reconstruction. To capture the full frequency spectrum, NeuroRVQ decomposes biosignals into frequency-specific representations via multi-scale temporal convolutions, each encoded into hierarchical RVQ codebooks to preserve high-frequency detail, combined with a novel phase-aware training loss that respects the circular topology of Fourier phase. By tuning the temporal resolution, number and size of temporal kernels and RVQ depth, this design adapts to the spectro-temporal characteristics of each biosignal modality. To validate that tokenizer quality drives downstream performance, we train a simple masked-token foundation model for each modality (NeuroRVQ-FM) using the corresponding NeuroRVQ tokenizer. The NeuroRVQ-FM family achieves competitive or superior downstream performance compared to existing modality-specific foundation models, demonstrating that high-fidelity tokenization is a critical factor for effective biosignal modeling.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
4 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:48 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

Paper and Review Summary

  • This paper proposes NeuroRVQ, a multi-scale residual vector-quantization tokenizer for biosignals across EEG, ECG, and EMG. It combines multi-scale temporal encoding, hierarchical RVQ codebooks, a Fourier-domain decoder, and a phase-aware reconstruction loss, then trains a masked-token foundation model on the learned discrete tokens. Two reviewers give borderline accept, while one gives reject. Overall, I view this as a borderline paper: the idea is promising and broadly evaluated, but the authors must clarify the experimental setup and provide comparable controls before the main claims can be fully trusted.

Strengths

  • Multi-modal biosignal tokenizer with broad scope: The paper studies discrete representation learning for EEG, ECG, and EMG, which is an important and timely problem for biosignal foundation models(Reviewer EV4Y, Reviewer oEvc, Reviewer ZD7f).

  • Multi-scale RVQ design for signal fidelity: The combination of multi-scale temporal branches and hierarchical RVQ is well aligned with the multi-frequency nature of biosignals and may help preserve high-frequency details(Reviewer EV4Y, Reviewer ZD7f).

  • Phase-aware reconstruction loss: The phase-aware loss is technically well motivated from a signal-processing perspective and appears to contribute substantially to reconstruction and downstream gains(Reviewer EV4Y, Reviewer oEvc, Reviewer ZD7f).

  • Extensive empirical coverage: The paper includes experiments across multiple modalities, datasets, downstream tasks, scaling settings, and ablations, giving initial evidence for the usefulness of the proposed tokenizer(Reviewer EV4Y, Reviewer ZD7f).

Weaknesses and Critical Concerns

  • Experimental setting does not fully isolate the tokenizer contribution: The central claim that tokenizer fidelity is decisive is not yet supported by a same-backbone, same-parameter, same-pretraining-data tokenizer-swap experiment. Without this, gains may be confounded by backbone size, data scale, training setup, or fine-tuning protocol(Reviewer oEvc, Reviewer EV4Y).

  • Full fine-tuning weakens representation-quality claims: Most downstream evaluations rely on full fine-tuning, making it unclear whether NeuroRVQ learns intrinsically transferable representations. Frozen-backbone or linear-probe results are needed to assess representation quality more cleanly(Reviewer oEvc, Reviewer ZD7f).

  • Codebook behavior is under-analyzed: For an RVQ method, the paper should report codebook utilization, perplexity, token usage distribution, and collapse statistics. It should also clarify how downstream performance changes with codebook size and number of branches(Reviewer EV4Y, Reviewer oEvc, Reviewer ZD7f).

  • Novelty and component attribution require clarification: The framework combines several established ideas, including multi-scale encoders, RVQ, Fourier-domain reconstruction, masked token prediction, and phase-aware losses. The authors need to clarify what is specifically novel and how much each component contributes, especially given that the phase-aware loss appears to drive a large part of the gain(Reviewer EV4Y, Reviewer oEvc).

  • Fairness of baselines and data protocols need clarification: The paper should clarify whether comparisons use matched normalization, reconstruction targets, pretraining data, and downstream protocols. It should also address possible pretraining/downstream overlap and compare with highly relevant multi-scale biosignal models such as CSBrain where appropriate(Reviewer oEvc, Reviewer ZD7f).

Critical Concerns Required to Address

  • Comparable tokenizer experiment: The authors should provide a controlled comparison under the same backbone, parameter budget, pretraining data, normalization, and downstream protocol. This should compare NeuroRVQ against alternative tokenizers or continuous embeddings to isolate the tokenizer effect.

  • Experimental protocol clarification: The authors should clearly specify pretraining data, downstream data, possible overlap control, normalization, reconstruction targets, fine-tuning protocol, and whether baseline settings are fully comparable.

  • Representation-quality evaluation: The authors should provide frozen-backbone or linear-probe results, or otherwise explain why full fine-tuning is sufficient to support the representation-learning claim.

  • Codebook analysis: The authors should report codebook utilization, perplexity, active token ratio, and collapse statistics, preferably across modalities and codebook sizes.

  • Component and scaling analysis: The authors should clarify the contribution of phase-aware loss versus tokenizer architecture, and report how downstream performance changes with number of branches, codebooks, and codebook size.

  • My current recommendation is borderline. The paper has a promising idea, useful signal-processing motivation, and broad empirical evaluation, but the experimental setup requires substantial clarification. In particular, the main claim that NeuroRVQ’s tokenizer is the decisive factor is not yet fully isolated from backbone, data, and fine-tuning confounds. A strong rebuttal with comparable experiments and protocol clarification could move the paper above the bar; otherwise, the concerns remain central.

Final justification

Since most concerns have been well-addressed during the rebuttal period, all reviewers agree with that this paper achieves the bar of acceptance. Currently, I lean towards acceptance.

Area Chair E8md · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

Paper and Review Summary

  • This paper proposes NeuroRVQ, a multi-scale residual vector-quantization tokenizer for biosignals across EEG, ECG, and EMG. It combines multi-scale temporal encoding, hierarchical RVQ codebooks, a Fourier-domain decoder, and a phase-aware reconstruction loss, then trains a masked-token foundation model on the learned discrete tokens. Two reviewers give borderline accept, while one gives reject. Overall, I view this as a borderline paper: the idea is promising and broadly evaluated, but the authors must clarify the experimental setup and provide comparable controls before the main claims can be fully trusted.

Strengths

  • Multi-modal biosignal tokenizer with broad scope: The paper studies discrete representation learning for EEG, ECG, and EMG, which is an important and timely problem for biosignal foundation models(Reviewer EV4Y, Reviewer oEvc, Reviewer ZD7f).

  • Multi-scale RVQ design for signal fidelity: The combination of multi-scale temporal branches and hierarchical RVQ is well aligned with the multi-frequency nature of biosignals and may help preserve high-frequency details(Reviewer EV4Y, Reviewer ZD7f).

  • Phase-aware reconstruction loss: The phase-aware loss is technically well motivated from a signal-processing perspective and appears to contribute substantially to reconstruction and downstream gains(Reviewer EV4Y, Reviewer oEvc, Reviewer ZD7f).

  • Extensive empirical coverage: The paper includes experiments across multiple modalities, datasets, downstream tasks, scaling settings, and ablations, giving initial evidence for the usefulness of the proposed tokenizer(Reviewer EV4Y, Reviewer ZD7f).

Weaknesses and Critical Concerns

  • Experimental setting does not fully isolate the tokenizer contribution: The central claim that tokenizer fidelity is decisive is not yet supported by a same-backbone, same-parameter, same-pretraining-data tokenizer-swap experiment. Without this, gains may be confounded by backbone size, data scale, training setup, or fine-tuning protocol(Reviewer oEvc, Reviewer EV4Y).

  • Full fine-tuning weakens representation-quality claims: Most downstream evaluations rely on full fine-tuning, making it unclear whether NeuroRVQ learns intrinsically transferable representations. Frozen-backbone or linear-probe results are needed to assess representation quality more cleanly(Reviewer oEvc, Reviewer ZD7f).

  • Codebook behavior is under-analyzed: For an RVQ method, the paper should report codebook utilization, perplexity, token usage distribution, and collapse statistics. It should also clarify how downstream performance changes with codebook size and number of branches(Reviewer EV4Y, Reviewer oEvc, Reviewer ZD7f).

  • Novelty and component attribution require clarification: The framework combines several established ideas, including multi-scale encoders, RVQ, Fourier-domain reconstruction, masked token prediction, and phase-aware losses. The authors need to clarify what is specifically novel and how much each component contributes, especially given that the phase-aware loss appears to drive a large part of the gain(Reviewer EV4Y, Reviewer oEvc).

  • Fairness of baselines and data protocols need clarification: The paper should clarify whether comparisons use matched normalization, reconstruction targets, pretraining data, and downstream protocols. It should also address possible pretraining/downstream overlap and compare with highly relevant multi-scale biosignal models such as CSBrain where appropriate(Reviewer oEvc, Reviewer ZD7f).

Critical Concerns Required to Address

  • Comparable tokenizer experiment: The authors should provide a controlled comparison under the same backbone, parameter budget, pretraining data, normalization, and downstream protocol. This should compare NeuroRVQ against alternative tokenizers or continuous embeddings to isolate the tokenizer effect.

  • Experimental protocol clarification: The authors should clearly specify pretraining data, downstream data, possible overlap control, normalization, reconstruction targets, fine-tuning protocol, and whether baseline settings are fully comparable.

  • Representation-quality evaluation: The authors should provide frozen-backbone or linear-probe results, or otherwise explain why full fine-tuning is sufficient to support the representation-learning claim.

  • Codebook analysis: The authors should report codebook utilization, perplexity, active token ratio, and collapse statistics, preferably across modalities and codebook sizes.

  • Component and scaling analysis: The authors should clarify the contribution of phase-aware loss versus tokenizer architecture, and report how downstream performance changes with number of branches, codebooks, and codebook size.

  • My current recommendation is borderline. The paper has a promising idea, useful signal-processing motivation, and broad empirical evaluation, but the experimental setup requires substantial clarification. In particular, the main claim that NeuroRVQ’s tokenizer is the decisive factor is not yet fully isolated from backbone, data, and fine-tuning confounds. A strong rebuttal with comparable experiments and protocol clarification could move the paper above the bar; otherwise, the concerns remain central.

Final justification

Since most concerns have been well-addressed during the rebuttal period, all reviewers agree with that this paper achieves the bar of acceptance. Currently, I lean towards acceptance.

5 comments
Authors · CommentOpenReview ↗

Response to Meta-Review / AC (1/4)

We thank the AC for the constructive and precise meta-review. We have addressed all five "Critical Concerns" identified by the AC and reviewers with new experiments and clarifications, provided in detail in our responses to the individual reviewers.

1. Comparable tokenizer experiment

The AC and Reviewers (EV4Y, ZD7f, oEvc) raised the question of how decisive the tokenizer fidelity is in downstream performance. We answer that with two experiments: a) with an experiment in the original submitted manuscript (Appendix K) and b) with a tokenizer-swap controlled ablation study as suggested by the AC.

LaBraM vs NeuroRVQ under-identical pre-training and benchmarking

In Appendix K, we have provided an analysis of two models LaBraM and NeuroRVQ-EEG where both models (as well as their corresponding tokenizers) are pre-trained and fine-tuned on the same datasets and with identical training, normalization and fine-tuning regimes. The results of Table 15 (the ERP task was added in the period between submission and the release of reviews) show that NeuroRVQ-EEG (which has a better quality tokenizer) achieves better downstream task performance:

Model Motor Memory Sleep Eyes ERP Mean
LaBraM 0.570 0.565 0.715 0.805 0.819 0.695
NeuroRVQ-EEG 0.700 0.573 0.728 0.869 0.876 0.749

Although LaBraM (5.8M) and NeuroRVQ-EEG (5.9M) share similar backbones (temporal encoders + transformers), they differ in the temporal encoder (LaBraM 1 branch vs NeuroRVQ 4) and in pre-training targets (1 vs 4×8 per masked token). So this analysis holds datasets, tokenizer training and pre-training/fine-tuning regimes identical, but the backbones differ slightly.

Tokenizer-Swap Controlled Ablation Study

To examine the effect of same backbone, parameter budget, pretraining data, normalization and downstream protocol within the rebuttal time-frame, we designed the following ablation: We use two tokenizers from Appendix B Table 2 (EEG): Row 2 (4-Branch, 8CB, MSE Phase + MSE A) and Row 5 (4-Branch, 8CB, Phase Loss + log(A) + Temporal), which share the same architecture and differ only in the training loss (val MSE 0.946 and 0.035 respectively). We pre-trained two NeuroRVQ-EEG models on PhysioNet-MI using these two tokenizers and benchmarked both on the High Gamma Motor dataset. We chose Motor deliberately: since both tokenizers and the foundation models are pretrained on PhysioNet-MI (a motor-imagery dataset), Motor (High Gamma) is the domain-matched task, which minimizes confounds and gives the cleanest isolation of the causal effect of tokenizer quality (as requested by the AC). It was not intended as an across-task generalization claim. Evaluation is under head-only (10-fold) and full-finetuning (5-fold, due to compute constraints) subject-wise cross-validation. The backbone architecture, parameter budget, pretraining data, normalization and downstream protocol are held identical. Only the tokenizer varies.

Tokenizer used to train same backbone model (corresponding val MSE) Head-Only Full
4-Branch, 8CB, MSE Phase + MSE A (0.946) 56.5 (8.59) 58.5 (3.19)
4-Branch, 8CB, Phase Loss + log(A) + Temporal (0.035) 58.9 (5.67) 64.0 (1.39)

The results from this controlled study show that even though both networks share the same backbone (our multi-scale architecture), pretraining data, normalization and downstream protocol, the one using a better tokenizer as pre-training target achieves the best downstream performance. A full generalization version of this specific ablation requires: a) training the tokenizers on all datasets (Appendix E), b) pretraining the foundation models on all datasets (Appendix E) and c) benchmarking across five tasks (for EEG). We hope the reviewers and AC appreciate that this is not feasible within the rebuttal window.

Summary of Results

In conclusion, the controlled ablation study ( (b) ) isolates if a higher-quality tokenizer helps in networks that share the same backbone, parameter budget, pretraining data, normalization and downstream protocol while Appendix K ( (a) ) demonstrates that this advantage generalizes across tasks. We hope these two complementary experiments alleviates the concerns about the tokenizer quality.

CSBrain

The AC and Reviewer ZD7f requested a comparison with the CSBrain model (which uses continous embeddings) in the EEG modality. We have added CSBrain as an EEG baseline in the revised Table 1. NeuroRVQ-EEG outperforms it on every task (except in Memory they are close) and on the mean (74.9 vs 69.9).

Model Motor ERP Memory Sleep Eyes Mean
CSBrain 67.1 ± 11.1 76.5 ± 5.7 57.0 ± 3.5 67.2 ± 3.8 81.9 ± 4.0 69.9 ± 5.6
NeuroRVQ-EEG 70.0 ± 7.3 87.6 ± 3.3 57.4 ± 2.7 72.8 ± 2.8 86.9 ± 2.6 74.9 ± 3.7
Authors · CommentOpenReview ↗

Response to Meta-Review / AC (2/4)

2. Experimental protocol clarification

In our response to Reviewer oEvc, we have clarified the normalization protocol and reconstruction targets for our analysis in Appendix F. We clarify that for BrainOmni we have used two normalization regimes (ours and BrainOmni's). Both results are present in the original manuscript. While for our analysis with LaBraM, we clarified that both tokenizers have the same normalization function in their respective properties. To compare both reconstructions, both signals are brought to the time domain and passed through the same normalization before MSE, so the comparison is scale-matched and neutral. In our response to Reviewer oEvc, we also clarified that no datasets across all modalities are present during pre-training and benchmarking. The only exception is "Eyes". We use PhysioNet-MI (only the motor trials) during pre-training. Therefore, in "Eyes" we acknowledge that there is subject-information leakage. However, EEGPT also uses PhysioNet-MI in their pre-training (possibly also the eyes trials). If we remove "Eyes" from Table 1, NeuroRVQ still leads.

Model Motor ERP Memory Sleep Mean
CBraMod 61.4 ± 10.4 77.7 ± 5.2 57.4 ± 3.8 63.5 ± 4.1 65.00
EEGPT 31.3 ± 3.5 66.8 ± 14.6 52.0 ± 1.7 63.4 ± 4.4 53.38
NeuroGPT 68.2 ± 8.3 75.7 ± 4.8 59.7 ± 2.9 67.4 ± 3.3 67.75
BrainOmni 58.5 ± 5.8 72.3 ± 4.1 51.8 ± 2.3 57.6 ± 5.5 60.05
LaBraM 63.0 ± 7.6 82.2 ± 4.0 52.6 ± 2.6 65.2 ± 3.7 65.75
REVE 69.4 ± 10.5 82.6 ± 4.3 59.3 ± 3.2 62.9 ± 3.5 68.55
NeuroRVQ-EEG 70.0 ± 7.3 87.6 ± 3.3 57.4 ± 2.7 72.8 ± 2.8 71.95

3. Representation-quality evaluation (frozen-backbone / linear-probe)

During the rebuttal phase, we add frozen-backbone results of NeuroRVQ in the EEG and EMG domain, as requested by the AC and Reviewers (oEvc and ZD7f). In EEG, NeuroRVQ-EEG outperforms the baselines on every task except Sleep and on the mean. We also report statistical signifance tests as suggested by the Reviewer ZD7f, including the cases that are statistical ties.

Model Motor Memory Sleep Eyes ERP Mean
NeuroGPT (full) 0.452 (0.047) 0.500 (0.000) 0.304 (0.010) 0.656 (0.048) 0.501 (0.002) 0.483 (0.021)
CBraMod 0.440 (0.077) 0.537 (0.016) 0.628 (0.044) 0.800 (0.034) 0.500 (0.000) 0.581 (0.034)
BIOT 0.335 (0.039) 0.528 (0.024) — 0.748 (0.046) 0.500 (0.000) —
LaBraM 0.327 (0.029) 0.500 (0.000) 0.303 (0.008) 0.733 (0.051) 0.500 (0.000) 0.473 (0.018)
EEGPT 0.331 (0.041) 0.541 (0.030) 0.634 (0.043) 0.815 (0.031) 0.523 (0.008) 0.569 (0.031)
REVE 0.574 (0.076) 0.568 (0.030) 0.616 (0.029) 0.761 (0.053) 0.728 (0.040) 0.649 (0.045)
NeuroRVQ-EEG 0.599 (0.044) 0.590 (0.033) 0.624 (0.028) 0.823 (0.035) 0.802 (0.038) 0.687 (0.036)

In the EMG domain, NeuroRVQ leads on every task.

Model EPN-612 Acc EPN-612 F1 NinaPro DB5 Acc NinaPro DB5 F1 UCI-EMG Acc UCI-EMG F1
PhysioWave 89.36 ± 0.16 89.43 ± 0.16 18.07 ± 0.91 16.71 ± 1.42 84.21 ± 1.57 84.01 ± 1.58
TinyMyo 75.28 ± 0.07 75.01 ± 0.09 21.60 ± 0.51 16.61 ± 0.49 83.67 ± 0.83 83.48 ± 0.93
NeuroRVQ-EMG 90.38 ± 0.04 90.41 ± 0.06 25.54 ± 0.68 21.91 ± 0.81 88.45 ± 1.06 88.45 ± 1.05
Authors · CommentOpenReview ↗

Response to Meta-Review / AC (3/4)

4. Codebook analysis

As suggested by the AC and Reviewers (EV4Y, oEvc, ZD7f), we added a codebook utilization analysis during the rebuttal period. Using the held-out validation sets per modality (EEG, ECG, EMG), we computed the following metrics across all branches (4 for all modalities) and RVQ levels (8 for EEG/ECG and 16 for EMG): utilization, perplexity, dead codes, top-1% mass (selection probability captured by the 1% most-used codes).

EEG

RVQ level Utilization Perplexity Dead codes Top-1% mass
1 80.9% 6099 1566 0.039
2 97.1% 7562 234 0.029
3 97.7% 7668 188 0.026
4 99.5% 7815 40 0.025
5 100.0% 7846 3 0.024
6 100.0% 7802 1 0.022
7 99.9% 7748 6 0.021
8 99.8% 7740 18 0.018
Mean 96.9% 7535 257 0.026

ECG

RVQ level Utilization Perplexity Dead codes Top-1% mass
1 29.2% 2060 5798 0.123
2 67.9% 4708 2631 0.068
3 54.3% 3846 3746 0.101
4 47.8% 3408 4280 0.100
5 53.0% 3805 3848 0.085
6 47.0% 3465 4342 0.091
7 47.0% 3544 4338 0.079
8 50.2% 3850 4076 0.060
Mean 49.6% 3586 4132 0.089

EMG

RVQ level Utilization Perplexity Dead codes Top-1% mass
1 88.1% 6442 978 0.053
2 100.0% 7331 1 0.049
3 99.9% 7355 5 0.048
4 100.0% 7388 0 0.046
5 100.0% 7418 2 0.044
6 100.0% 7454 0 0.042
7 100.0% 7488 1 0.039
8 100.0% 7517 0 0.037
9 100.0% 7541 0 0.036
10 100.0% 7568 0 0.035
11 100.0% 7618 0 0.034
12 100.0% 7632 0 0.034
13 100.0% 7733 0 0.032
14 100.0% 7812 0 0.030
15 100.0% 7844 0 0.028
16 100.0% 7913 0 0.027
Mean 99.2% 7503 62 0.038

NeuroRVQ shows efficient code usage with no collapse: EEG and EMG reach 96.9% and 99.2% mean utilization with near-uniform usage and only 257 and 62 dead codes per 8192-entry codebook respectively. Within each modality the coarse first RVQ level has the lowest utilization while deeper residual levels saturate toward 100%, with perplexity increasing and top-code concentration decreasing monotonically with depth. This behavior is a residual hierarchy: first levels produce coarse details and successive levels encode progressively finer detail spread across the full codebook. ECG shows lower utilization (49.6%): this is expected and consistent with our scaling analysis (Section 4.2), which found that ECG's stereotyped spectrally simple morphology saturates with far fewer codebooks than EEG or EMG.

Reviewer ZD7fOpenReview ↗
Rating
5/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper introduces NeuroRVQ, a novel biosignal tokenizer designed for high-fidelity signal reconstruction. To preserve high-frequency details, NeuroRVQ decomposes biosignals using hierarchical Residual Vector Quantization (RVQ) codebooks and employs multi-scale temporal convolutions to capture information across various frequency ranges. By combining a multi-branch temporal RVQ mechanism with a novel phase loss function, which is absent in prior literature, NeuroRVQ achieves superior reconstruction performance compared to existing methods. Furthermore, the authors introduce NeuroRVQ-FM, a foundation model trained via a masked-token prediction objective. To isolate and validate the specific contributions of the tokenizer, the architecture of NeuroRVQ-FM is kept simple. Despite that, NeuroRVQ-FM still outperforms baseline models across multiple datasets on three biosignal modalities: EEG, EMG, and ECG.

Strengths and weaknesses

Strengths:

  • The paper considers the multi-scale structure, an aspect often overlooked by existing models, which subsequently leads to a low-frequency bias.
  • The novel phase loss effectively fills a critical gap in existing methods.
  • The paper presents a comprehensive ablation study that clearly validates the architectural design choices.

Weaknesses:

  • There is a risk that the tokenizer might learn more subject-specific details and noise rather than robust representations. Although the authors have discussed this concern in the Discussion section, their claims do not have any theoretical or empirical support. While a larger or different codebook might yield better signal reconstruction, it does not guarantee superior performance on downstream tasks. The paper lacks a downstream task comparison with varying codebook sizes.

  • The evaluation relies on full fine-tuning experiments, which fails to definitively prove that the pre-trained representations are inherently beneficial since the entire network is trained during the downstream phase. Conducted experiments using linear probing would provide a much clearer assessment of the learned representations' quality.

  • The paper lacks a baseline comparison with a highly relevant work, CSBrain [1], which also utilizes multi-scale convolutional layers. A direct comparison with CSBrain is necessary to demonstrate the advantages of using discrete versus continuous embeddings.

Questions
  • Could the authors clarify how spatial information is handled? Channel dimension C carries critical information for biosignals. While the paper mentions the SE blocks, it also states that the multi-variate biosignal is represented by P patches of length w. It is unclear whether the channel dimension C is preserved throughout this process or not.

  • Have the authors analyzed the actual codebook utilization? It would be insightful to know if the model suffers from codebook collapse (only a fraction of the codebook is actively used) or if the codebook space is efficiently exploited.

  • Do the authors think it is possible to develop a unified tokenizer shared across multiple modalities? Since different biosignals often share some physiological information, it is worth exploring whether some first codebooks of the RVQ could capture domain-agnostic information.

Reference:

[1] Zhou, Yuchen, et al. "Csbrain: A cross-scale spatiotemporal brain foundation model for eeg decoding." Advances in Neural Information Processing Systems 38 (2026): 87150-87195.

Limitations

Yes

Final justification

The authors' explanations thoroughly address my concerns, particularly for codebook utilization and the linear probe results. Following the first rebuttal, I raised two follow-up questions concerning the significance tests for the linear probe results and the choice of downstream tasks during rebuttal. The authors have satisfactorily answered these additional questions as well. Therefore, I decide to increase my score from 4 to 5.

Formatting concerns

I haven't noticed any major issues in this paper with respect to violation of formatting, anonymity.

5 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for their positive assessment and for recognizing the importance of our model's multi-scale structure and the novel phase loss. In the revised paper, we will add the results described below.

Channel Information

Channel information is preserved throughout the model. Consider the example of a 4-channel EEG signal with 2 seconds per channel. With a patch length of 1 second, the signal is split into 8 patches. Each patch retains its channel identity via two learned embeddings: a spatial embedding (SE), which tells the model which channel a patch comes from and a temporal embedding, which encodes its time position within the channel. The multi-scale encoder operates purely in the time domain and never mixes across channels. Cross-channel information is integrated in the transformer encoders, where self-attention operates over all patches.

Frozen-Backbone

We agree that frozen-backbone evaluation isolates representation quality. For every EEG model (we will run the EMG and ECG studies), we use the authors' original architecture (frozen) and weights, adding a trainable classification head to each architecture's features. For NeuroRVQ, we used all the tokens produced by the multi-branches as input to the linear layer. The results of classification-head-only training are shown below in the format of mean_bacc (std):

Model Motor Memory Sleep Eyes ERP Mean
NeuroGPT (full) 0.452 (0.047) 0.500 (0.000) 0.304 (0.010) 0.656 (0.048) 0.501 (0.002) 0.483 (0.021)
CBraMod 0.440 (0.077) 0.537 (0.016) 0.628 (0.044) 0.800 (0.034) 0.500 (0.000) 0.581 (0.034)
LaBraM 0.327 (0.029) 0.500 (0.000) 0.303 (0.008) 0.733 (0.051) 0.500 (0.000) 0.473 (0.018)
EEGPT 0.331 (0.041) 0.541 (0.030) 0.634 (0.043) 0.815 (0.031) 0.523 (0.008) 0.569 (0.031)
REVE 0.574 (0.076) 0.568 (0.030) 0.616 (0.029) 0.761 (0.053) 0.728 (0.040) 0.649 (0.045)
NeuroRVQ 0.599 (0.044) 0.590 (0.033) 0.624 (0.028) 0.823 (0.035) 0.802 (0.038) 0.687 (0.036)

Codebook Utilization

Codebook utilization is an important property for RVQ-based tokenizer. Using the held-out validation sets per modality (EEG, ECG, EMG), we computed the following metrics across all branches (4 for all modalities) and RVQ levels (8 for EEG/ECG and 16 for EMG): utilization, perplexity, dead codes, top-1% mass (selection probability captured by the 1% most-used codes). For complete per-level analysis, please see our response to Reviewer EV4Y.

Modality RVQ levels Utilization Perplexity Dead codes Top-1% mass
EEG 8 96.9% 7535 257 0.026
ECG 8 49.6% 3586 4132 0.089
EMG 16 99.2% 7503 62 0.038

NeuroRVQ shows efficient code usage with no collapse: EEG and EMG reach 96.9% and 99.2% mean utilization with near-uniform usage and only 257 and 62 dead codes per 8192-entry codebook respectively. Within each modality the coarse first RVQ level has the lowest utilization while deeper residual levels saturate toward 100%, with perplexity increasing and top-code concentration decreasing monotonically with depth. This behavior is a residual hierarchy: first levels produce coarse details and successive levels encode progressively finer detail spread across the full codebook. ECG shows lower utilization (49.6%): this is expected and consistent with our scaling analysis (Section 4.2), which found that ECG's stereotyped spectrally simple morphology saturates with far fewer codebooks than EEG or EMG.

Reconstruction and downstream performance

In Appendix K, we have provided an analysis of two models LaBraM and NeuroRVQ-EEG where both models (as well as their corresponding tokenizers) are pre-trained and fine-tuned on the same datasets and with identical training and fine-tuning regimes. The results of Table 15 (the ERP task was added in the period between submission and the release of reviews) show that NeuroRVQ (which has a better quality tokenizer) achieves better downstream task performance:

Model Motor Memory Sleep Eyes ERP Mean
LaBraM 0.570 0.565 0.715 0.805 0.819 0.695
NeuroRVQ-EEG 0.700 0.573 0.728 0.869 0.876 0.749

Although LaBraM (5.8M) and NeuroRVQ-EEG (5.9M) share similar backbones (temporal encoders + transformers), they differ in the temporal encoder (LaBraM 1 branch vs NeuroRVQ 4) and in pre-training targets (1 vs 4×8 per masked token). So this analysis holds datasets, tokenizer training and pre-training/fine-tuning regimes identical, but the backbones differ slightly.

To examine the effect of same backbone, parameter budget, pretraining data, normalization and downstream protocol within the rebuttal time-frame, we designed the following ablation: We use two tokenizers from Appendix B Table 2 (EEG): Row 2 (4-Branch, 8CB, MSE Phase + MSE A) and Row 5 (4-Branch, 8CB, Phase Loss + log(A) + Temporal), which share the same architecture and differ only in the training loss (val MSE 0.946 and 0.035 respectively). We pre-trained two NeuroRVQ-EEG models on PhysioNet-MI using these two tokenizers and benchmarked both on the High Gamma Motor dataset. We chose Motor because the tokenizers and consequently the foundation models are pre-trained on PhysioNet-MI (a motor dataset), and Motor is the downstream task most closely matched to that pretraining domain. Evaluation is under head-only (10-fold) and full-finetuning (5-fold, due to compute constraints) subject-wise cross-validation. In other words, backbone architecture, parameter budget, pretraining data, normalization and downstream protocol are held identical. Only the tokenizer varies. The results show that tokenization quality translates into downstream performance: balanced accuracy improves with tokenizer fidelity and the effect is clearest under full fine-tuning.

Tokenizer used to train same backbone model (corresponding val MSE) Head-Only Full
4-Branch, 8CB, MSE Phase + MSE A (0.946) 56.5 (8.59) 58.5 (3.19)
4-Branch, 8CB, Phase Loss + log(A) + Temporal (0.035) 58.9 (5.67) 64.0 (1.39)

We extended this ablation study to other tokenizers from Section 4.2 (Figure 2) in the EEG modality. To examine the relationship between number of codebooks and downstream performance, we used the tokenizers with (a) 4-Branch, 1CB (b) 4-Branch, 2CB and (c) 4-Branch, 8CB, which keeps the same architecture and training loss but scales only the number of codebooks.

Tokenizer used to train same backbone model (corresponding val MSE) Head-Only Full
4-Branch, 1CB (0.35) 59.0 (4.91) 62.7 (1.61)
4-Branch, 2CB (0.12) 59.1 (6.09) 63.5 (2.23)
4-Branch, 8CB (0.035) 58.9 (5.67) 64.0 (1.39)

We notice that once the tokenizer faithfully reconstructs task-relevant structure (motor in this case), further fidelity captures detail less relevant to the label with diminishing returns: a 10× MSE reduction (0.35→0.035) yields modest gain (saturation), whereas the low vs very good fidelity loss swap (0.946→0.035) gives a large 58.5→64.0. Under head-only probing the top tokenizers are indistinguishable (58.9–59.1, within across-fold std), while full fine-tuning separates them cleanly.

CSBrain

We thank the reviewer for pointing to this highly relevant model. We have added CSBrain as an EEG baseline in the revised Table 1. On the four EEG tasks completed so far it is competitive with other recent baselines (Motor 67.1, Sleep 57.0, Eyes 81.9). Its ERP (KU ERP) run is still completing and will be included in the camera-ready. CSBrain uses continuous cross-scale embeddings, whereas NeuroRVQ produces discrete tokens. We have added this discrete-vs-continuous distinction to the related-work discussion. We also note that we have strengthened Table 1: REVE was added to Table 1 in the period between submission and the release of reviews and we completed the BrainOmni comparison in the same period. Against this expanded and more competitive set, NeuroRVQ-EEG retains the best mean balanced accuracy (74.9).

Model Motor ERP Memory Sleep Eyes Mean
REVE 69.4 ± 10.5 82.6 ± 4.3 59.3 ± 3.2 62.9 ± 3.5 79.9 ± 3.4 70.8 ± 4.9
CSBrain 67.1 ± 11.1 — 57.0 ± 3.5 67.2 ± 3.8 81.9 ± 4.0 —
NeuroRVQ-EEG 70.0 ± 7.3 87.6 ± 3.3 57.4 ± 2.7 72.8 ± 2.8 86.9 ± 2.6 74.9 ± 3.7

Unified Tokenizer

This is an insightful future direction. The reviewer's intuition that the coarse first RVQ codebooks might capture domain-agnostic structure while deeper levels specialize is consistent with what we observe in the Codebook Utilization section above. A "shared-early / specialized-late" RVQ is therefore a plausible architecture for cross-modal sharing and we agree it is worth exploring. However, our Section 4 results suggest a single, fully shared tokenizer is unlikely to be optimal: the modalities differ substantially in sampling rate and spectro-temporal structure, which is why key hyperparameters (patch length, kernel sizes, RVQ depth) are tuned per modality (e.g. 8 RVQ levels for EEG/ECG vs. 16 for EMG) and why codebook usage differs. A one-size-fits-all configuration could be feasible only if reconstruction quality in some modalities is sacrificed. We therefore see the more promising path to unified biosignal modeling not as a single shared tokenizer, but as a set of modality-specific NeuroRVQ tokenizers feeding a shared foundation model. This is precisely why we designed NeuroRVQ as a modality-adaptive tokenizer family: to give the community a tool for building both stronger single-modality and future multi-modal biosignal foundation models. We will add this discussion to the revised paper.

Reviewer ZD7f · CommentOpenReview ↗

Thanks to the authors for their rebuttal. Based on that, I have some additional questions:

  • In the Frozen-Backbone experiments, the high standard deviations (for example, in Motor, Memory, Sleep, and Mean) overlap significantly with the performance gaps. Could the authors provide statistical significance tests to confirm that NeuroRVQ's improvements over the baselines are not merely due to random noise?

  • In ‘Reconstruction and downstream performance’ part of the rebuttal, the authors evaluate solely on a downstream Motor task (which closely matches the pre-training domain). This only demonstrates in-domain improvement. While I understand the time constraints for the rebuttal, a lower MSE here might indicate overfitting to that task rather than true generalizability to other tasks. How do the authors address this concern?

Authors · CommentOpenReview ↗

Response to Reviewer ZD7f's Follow-Up Question

We thank the reviewer for their feedback. We address every follow-up question with new evidence and clarifications below.

Statistical significance of frozen-backbone results

To confirm these improvements are not due to fold-to-fold noise, we ran paired significance tests (Wilcoxon signed-rank across the 10 cross-validation folds with per-fold win counts) comparing NeuroRVQ-EEG against each foundation model baseline. NeuroRVQ-EEG significantly outperforms every baseline on the mean across tasks and on the large majority of individual tasks. On the four tasks the reviewer highlights: NeuroRVQ-EEG's improvement is significant on Mean (p=0.002) and Memory (p=0.002) against every baseline. On Motor, it is significant against every baseline except REVE (a tie, p=0.32). And on Sleep, it is significant against NeuroGPT and LaBraM but tied with CBraMod and EEGPT, the two strongest baselines on that task.

NeuroRVQ-EEG vs Motor Memory Sleep Eyes ERP Mean
NeuroGPT 9/10 (p=0.004) 10/10 (p=0.002) 10/10 (p=0.002) 10/10 (p=0.002) 10/10 (p=0.002) 10/10 (p=0.002)
CBraMod 10/10 (p=0.002) 10/10 (p=0.002) 4/10 (p=0.432) 6/10 (p=0.105) 10/10 (p=0.002) 10/10 (p=0.002)
BIOT 10/10 (p=0.002) 10/10 (p=0.002) — 10/10 (p=0.002) 10/10 (p=0.002) —
LaBraM 10/10 (p=0.002) 10/10 (p=0.002) 10/10 (p=0.002) 10/10 (p=0.002) 10/10 (p=0.002) 10/10 (p=0.002)
EEGPT 10/10 (p=0.002) 9/10 (p=0.004) 3/10 (p=0.232) 7/10 (p=0.432) 10/10 (p=0.002) 10/10 (p=0.002)
REVE 6/10 (p=0.322) 9/10 (p=0.004) 8/10 (p=0.049) 9/10 (p=0.004) 10/10 (p=0.002) 10/10 (p=0.002)

Motor Overfitting Concern

We thank the reviewer and would like to clarify the purpose of that experiment. The tokenizer-swap in our original response is a controlled ablation study, requested by the Area Chair and the reviewer to isolate the effect of the tokenizer while holding the backbone, parameter budget, pretraining data, normalization and downstream protocol fixed. For this purpose, we pretrained two NeuroRVQ-EEG models on PhysioNet-MI using two tokenizers of differing quality (already pre-trained for Appendix B) and evaluated on High Gamma Motor dataset. We chose Motor deliberately: since both tokenizers and the foundation models are pretrained on PhysioNet-MI (a motor-imagery dataset), Motor is the domain-matched task, which minimizes confounds and gives the cleanest isolation of the causal effect of tokenizer quality. It was not intended as an across-task generalization claim.

Tokenizer used to train same backbone model (corresponding val MSE) Head-Only Full
4-Branch, 8CB, MSE Phase + MSE A (0.946) 56.5 (8.59) 58.5 (3.19)
4-Branch, 8CB, Phase Loss + log(A) + Temporal (0.035) 58.9 (5.67) 64.0 (1.39)

The results from this controlled study show that even though both networks share the same backbone (our multi-scale architecture), pretraining data, normalization and downstream protocol, the one using a better tokenizer as pre-training target achieves the best downstream performance.

A full generalization version of this specific ablation requires: a) training both the tokenizers and foundation models on all datasets (Appendix E) and b) benchmarking across five tasks (for EEG). We hope the reviewer appreciates that this is not feasible within the rebuttal window.

The reviewer is concerned that this ablation study shows only in-domain improvement. As described in our original rebuttal response, generalization to other tasks is established by our matched-training comparison in Appendix K, where LaBraM(5.8M) and NeuroRVQ-EEG(5.9M) (and their tokenizers) are pretrained and fine-tuned on identical datasets (Appendix E) under identical training and fine-tuning regimes. The primary difference is the tokenizer, whose reconstruction quality differs substantially (LaBraM's is far lower see Appendix H). Their backbone models are similar (temporal encoders + transformers) but they differ in the temporal encoder (LaBraM 1 branch vs NeuroRVQ 4). Crucially, this comparison is evaluated across the full downstream benchmark and shows that NeuroRVQ-EEG significantly outperforms LaBraM.

Model Motor Memory Sleep Eyes ERP Mean
LaBraM 0.570 0.565 0.715 0.805 0.819 0.695
NeuroRVQ-EEG 0.700 0.573 0.728 0.869 0.876 0.749

In conclusion, the controlled ablation study isolates if a higher-quality tokenizer helps in networks that share the same backbone, parameter budget, pretraining data, normalization and downstream protocol (reviewer's original question) while Appendix K demonstrates that this advantage generalizes across tasks (reviewer's followup question). We hope this clarifies that the two experiments are complementary and that our results reflect genuine representational quality.

Reviewer oEvcOpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

NeuroRVQ is a modality-adaptive tokenizer for biosignals (EEG/ECG/EMG): a multi-scale temporal encoder with per-branch Residual Vector Quantization, a Fourier-domain decoder, and a phase-aware reconstruction loss that respects the circular topology of phase via a cosine-similarity term. A deliberately simple masked-token foundation model is pretrained per modality. Across 13 downstream datasets the paper reports state-of-the-art or competitive results (e.g., EEG mean balanced accuracy 74.9% vs. 70.7%; ~2× balanced accuracy on the 43-class ECG task). The headline claim is that high-fidelity tokenization, not model scale, is the decisive factor.

Strengths and weaknesses

Strengths. The phase-aware loss is principled and correct (Appendix A) and is the strongest contribution; most biosignal-tokenizer papers omit this signal-processing reasoning. Evaluation is broad across three modalities, and the emphasis on balanced accuracy is appropriate for imbalanced clinical labels. The additive component ablation isolates contributions, with the phase loss driving the largest single EEG gain.

Weaknesses. (1) The central claim is not isolated: there is no same-backbone, same-parameter, same-pretraining-data tokenizer-swap experiment, so gains are confounded with model scale and data volume; all downstream numbers are fully fine-tuned, with no frozen/linear-probe evaluation. (2) No codebook-utilization, perplexity, or collapse statistics are reported — a critical omission for an RVQ method. (3) The reconstruction→downstream link is asserted but never plotted, and the ~67× reconstruction gap over LaBraM is implausible without controls (possible normalization mismatch / strawman). (4) On PTB-XL 5-class, NeuroRVQ underperforms ECGFounder, yet the narrative foregrounds the 43-class win; no code/data or ethics statement is provided.

Questions
  1. Do the authors have a same-backbone tokenizer-swap ablation (parameters and pretraining-data matched)? Without it, how is "tokenizer fidelity is decisive" defended against scale/data confounds? This is decisive for my score.
  2. Report RVQ codebook utilization/perplexity/collapse, and add frozen/linear-probe results vs. at least LaBraM.
  3. Plot reconstruction fidelity against downstream balanced accuracy; explain the 67× LaBraM gap under each method's native reconstruction target with matched normalization. 4.Guarantee no subject/recording/dataset overlap between tokenizer pretraining and downstream evaluation (esp. TUH, MIMIC-IV-ECG).
Limitations

Acknowledges per-modality scope and compute-bounded scaling, but omits the limitations most central to the claim: no tokenizer-isolating control, all-fine-tuned evaluation, missing fidelity↔downstream link, and absent reproducibility artifacts.

Final justification

I gave the lowest score in the original round, on the grounds that the central claim — that tokenizer fidelity rather than scale or data drives the gains — was not isolated by any controlled experiment, that all downstream evaluation was fully fine-tuned, that no codebook statistics were reported for an RVQ method, and that the 67× reconstruction gap over LaBraM was not credible without controls. I stated that a same-backbone tokenizer-swap was decisive for my score.

The authors ran it. Holding backbone, parameter budget, pretraining data, normalisation and downstream protocol fixed and varying only the tokenizer gives 58.5 → 64.0 balanced accuracy. They also added frozen-backbone evaluation, where NeuroRVQ-EEG leads on mean (.687 vs .649 for the strongest baseline) with paired Wilcoxon tests reported including ties; full per-level codebook utilisation, perplexity and dead-code statistics across three modalities; a re-run of the reconstruction comparison at 0.1–100 Hz, a band unfavourable to their model, which preserves the gap (0.142 vs 2.009); an explicit audit of pretraining/downstream overlap that discloses subject-level leakage on "Eyes" and shows the ranking is unchanged without it; and CSBrain as an additional continuous-embedding baseline. My four objections are answered, and I withdraw the reject.

Three things keep me at 4 rather than higher. First, the swap compares two of the authors' own tokenizers differing in training loss, on a single task matched to the pretraining domain; the cross-family and cross-task evidence (Appendix K) comes from backbones that are similar but not identical. Reviewer ZD7f's version of this concern is well founded. Second, the authors' own scaling ablation is a saturation result — a 10× MSE reduction buys 62.7 → 64.0 — which contradicts the paper's headline framing that fidelity is decisive; the supportable claim is that fidelity matters sharply up to the point where task-relevant structure is captured, and that the phase-aware loss rather than codebook scale is the source of the gain. The paper should be reframed accordingly. Third, ECG codebook utilisation of 49.6% with 4132 dead codes should be reported as over-provisioning rather than as "no collapse", and code release should not wait for acceptance.

The phase-aware loss remains, in my view, the paper's real contribution: it is a correct treatment of a failure mode that prior biosignal tokenizers get wrong, and the rebuttal now shows it is also where the downstream gain comes from.

Raising Rating from 2 to 4; Quality 2 → 3; Significance 2 → 3; Originality unchanged at 2, since the architecture remains an integration of established components.

Formatting concerns

None

3 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for their comments and address each point with new evidence.

Tokenizer-Swap

The main question of the reviewer is how "decisive the tokenizer fidelity is". Although, we have tried to answer that in our original manuscript, the reviewer is right that a tokenizer-swap with the same backbone is neccessary.

In Appendix K, we have provided an analysis of two models LaBraM and NeuroRVQ-EEG where both models (as well as their corresponding tokenizers) are pre-trained and fine-tuned on the same datasets and with identical training and fine-tuning regimes. The results of Table 15 (ERP was added in the period between submission and the release of reviews) show that NeuroRVQ (which has a better quality tokenizer) achieves better downstream task performance:

Model Motor Memory Sleep Eyes ERP Mean
LaBraM 0.570 0.565 0.715 0.805 0.819 0.695
NeuroRVQ-EEG 0.700 0.573 0.728 0.869 0.876 0.749

Although LaBraM (5.8M) and NeuroRVQ-EEG (5.9M) share similar backbones (temporal encoders + transformers), they differ in the temporal encoder (LaBraM 1 branch vs NeuroRVQ 4) and in pre-training targets (1 vs 4×8 per masked token). So this analysis holds datasets, tokenizer training and pre-training/fine-tuning regimes identical, but the backbones differ slightly.

To examine the effect of same backbone, parameter budget, pretraining data, normalization and downstream protocol within the rebuttal time-frame, we designed the following ablation: We use two tokenizers from Appendix B Table 2 (EEG): Row 2 (4-Branch, 8CB, MSE Phase + MSE A) and Row 5 (4-Branch, 8CB, Phase Loss + log(A) + Temporal), which share the same architecture and differ only in the training loss (val MSE 0.946 and 0.035 respectively). We pre-trained two NeuroRVQ-EEG models on PhysioNet-MI using these two tokenizers and benchmarked both on the High Gamma Motor dataset. We chose Motor because the tokenizers and consequently the foundation models are pre-trained on PhysioNet-MI (a motor dataset), and Motor is the downstream task most closely matched to that pretraining domain. Evaluation is under head-only (10-fold) and full-finetuning (5-fold, due to compute constraints) subject-wise cross-validation. In other words, backbone architecture, parameter budget, pretraining data, normalization and downstream protocol are held identical. Only the tokenizer varies. The results show that tokenization quality translates into downstream performance: balanced accuracy improves with tokenizer fidelity and the effect is clearest under full fine-tuning.

Tokenizer used to train same backbone model (corresponding val MSE) Head-Only Full
4-Branch, 8CB, MSE Phase + MSE A (0.946) 56.5 (8.59) 58.5 (3.19)
4-Branch, 8CB, Phase Loss + log(A) + Temporal (0.035) 58.9 (5.67) 64.0 (1.39)

Within the rebuttal period, we extended this ablation study to other tokenizers from Section 4.2 (Figure 2) in the EEG modality. To examine the relationship between number of codebooks and downstream performance, we used the tokenizers with (a) 4-Branch, 1CB (b) 4-Branch, 2CB and (c) 4-Branch, 8CB, which keeps the same architecture and training loss but scales only the number of codebooks.

Tokenizer used to train same backbone model (corresponding val MSE) Head-Only Full
4-Branch, 1CB (0.35) 59.0 (4.91) 62.7 (1.61)
4-Branch, 2CB (0.12) 59.1 (6.09) 63.5 (2.23)
4-Branch, 8CB (0.035) 58.9 (5.67) 64.0 (1.39)

We notice that once the tokenizer faithfully reconstructs task-relevant structure (motor in this case), further fidelity captures detail less relevant to the label with diminishing returns: a 10× MSE reduction (0.35→0.035) yields modest gain (saturation), whereas the low-vs-sufficient-fidelity loss swap (0.946→0.035) gives a large 58.5→64.0. Under head-only probing the top tokenizers are indistinguishable (58.9–59.1, within across-fold std), while full fine-tuning separates them cleanly.

We hope that this ablation study satisfies the reviewer's main concern, decisive for their score.

Codebook Utilization

Codebook utilization is an important property for an RVQ-based tokenizer. Using the held-out validation sets per modality (EEG, ECG, EMG), we computed the following metrics across all branches (4 for all modalities) and RVQ levels (8 for EEG/ECG and 16 for EMG): utilization, perplexity, dead codes, top-1% mass (selection probability captured by the 1% most-used codes). For complete per-level analysis, please see our response to Reviewer EV4Y.

Modality RVQ levels Util. Perpl. Dead Top-1% mass
EEG 8 96.9% 7535 257 0.026
ECG 8 49.6% 3586 4132 0.089
EMG 16 99.2% 7503 62 0.038

NeuroRVQ shows efficient code usage with no collapse: EEG and EMG reach 96.9% and 99.2% mean utilization with near-uniform usage and only 257 and 62 dead codes per 8192-entry codebook respectively. Within each modality the coarse first RVQ level has the lowest utilization while deeper residual levels saturate toward 100%, with perplexity increasing and top-code concentration decreasing monotonically with depth. This behavior is a residual hierarchy: first levels produce coarse details and successive levels encode progressively finer detail spread across the full codebook. ECG shows lower utilization (49.6%): this is expected and consistent with our scaling analysis (Section 4.2), which found that ECG's stereotyped spectrally simple morphology saturates with far fewer codebooks than EEG or EMG.

Frozen-Backbone

We agree that frozen-backbone evaluation isolates representation quality. For every EEG model (we will run the EMG and ECG studies), we use the authors' original architecture (frozen) and weights, adding a trainable classification head to each architecture's features. For NeuroRVQ, we used all the tokens produced by the multi-branches as input to the linear layer. The results of classification-head-only training are shown below in the format of mean_bacc (std):

Model Motor Memory Sleep Eyes ERP Mean
NeuroGPT (full) 0.452 (0.047) 0.500 (0.000) 0.304 (0.010) 0.656 (0.048) 0.501 (0.002) 0.483 (0.021)
CBraMod 0.440 (0.077) 0.537 (0.016) 0.628 (0.044) 0.800 (0.034) 0.500 (0.000) 0.581 (0.034)
LaBraM 0.327 (0.029) 0.500 (0.000) 0.303 (0.008) 0.733 (0.051) 0.500 (0.000) 0.473 (0.018)
EEGPT 0.331 (0.041) 0.541 (0.030) 0.634 (0.043) 0.815 (0.031) 0.523 (0.008) 0.569 (0.031)
REVE 0.574 (0.076) 0.568 (0.030) 0.616 (0.029) 0.761 (0.053) 0.728 (0.040) 0.649 (0.045)
NeuroRVQ-EEG 0.599 (0.044) 0.590 (0.033) 0.624 (0.028) 0.823 (0.035) 0.802 (0.038) 0.687 (0.036)

Reconstruction

In Appendix F, we present a reconstruction comparison between NeuroRVQ and pre-trained (by the original authors) LaBraM and BrainOmni tokenizers. In the case of BrainOmni, BrainOmni’s publicly available sample data with two normalization regimes (ours and BrainOmni's). For LaBraM, we used two datasets (not present during pre-training in any model). Both LaBraM and NeuroRVQ have the normalization function in their respective properties. To compare both reconstructions, both signals are brought to the time domain and passed through the same normalization before MSE, so the comparison is scale-matched and neutral (no normalization issue in either in-distribution 67x or out-of-distribution 22x). However, LaBraM is pre-trained 0.1–75 Hz and fs=200Hz while NeuroRVQ 0.1–45 Hz and fs=200Hz. The results of Table 10 are from data filtered between 0.1-45Hz which might slightly benefit NeuroRVQ. During the rebuttal, to directly address the concern that the gap could reflect a favorable filtering or normalization choice, we re-ran the comparison on High Gamma with data filtered 0.1–100 Hz, a wider band than NeuroRVQ's training range, which if anything disadvantages NeuroRVQ. NeuroRVQ still reconstructs with far lower error:

Model Reconstruction MSE
LaBraM 2.009
NeuroRVQ 0.142

The reconstruction advantage over LaBraM is attributable to specific ablated components: (i) the topologically-correct phase loss (Appendix A, B) and (ii) multi-scale RVQ (Appendix B, Section 4.2). In the controlled tokenizer-swap, replacing the raw-phase MSE objective with our phase-aware loss alone reduces tokenizer reconstruction MSE from 0.946 to 0.035 and improves downstream Motor from 58.5 to 64.0.

Code

The model code and trained weights will be publicly released upon acceptance. A demo reconstruction code can be provided to the AC, if the reviewer or Area Chair consider access necessary during the rebuttal period.

Datasets

For NeuroRVQ, no datasets across all modalities are present during pre-training and benchmarking. The only exception is "Eyes". We use PhysioNet-MI (only motor trials) during pre-training. Therefore, in "Eyes" we acknowledge that there is subject-information leakage. However, EEGPT also uses PhysioNet-MI in their pre-training (possibly also the eyes trials). However, if we remove "Eyes" from Table 1, NeuroRVQ still leads.

Model Motor ERP Memory Sleep Mean
CBraMod 61.4 ± 10.4 77.7 ± 5.2 57.4 ± 3.8 63.5 ± 4.1 65.00
EEGPT 31.3 ± 3.5 66.8 ± 14.6 52.0 ± 1.7 63.4 ± 4.4 53.38
NeuroGPT 68.2 ± 8.3 75.7 ± 4.8 59.7 ± 2.9 67.4 ± 3.3 67.75
BrainOmni 58.5 ± 5.8 72.3 ± 4.1 51.8 ± 2.3 57.6 ± 5.5 60.05
LaBraM 63.0 ± 7.6 82.2 ± 4.0 52.6 ± 2.6 65.2 ± 3.7 65.75
REVE 69.4 ± 10.5 82.6 ± 4.3 59.3 ± 3.2 62.9 ± 3.5 68.55
NeuroRVQ-EEG 70.0 ± 7.3 87.6 ± 3.3 57.4 ± 2.7 72.8 ± 2.8 71.95
Authors · CommentOpenReview ↗

Extra Rebuttal Results

Frozen-backbone on EMG

Since our original rebuttal, we extended the frozen-backbone analysis to EMG. With the backbone frozen and only the classification head trained, we evaluated (1-second windows) on EPN-612, NinaPro DB5 and UCI-EMG. NeuroRVQ-EMG outperforms both baselines on every task, demonstrating the representational quality of the backbone.

Model EPN-612 Acc EPN-612 F1 NinaPro DB5 Acc NinaPro DB5 F1 UCI-EMG Acc UCI-EMG F1
PhysioWave 89.36 ± 0.16 89.43 ± 0.16 18.07 ± 0.91 16.71 ± 1.42 84.21 ± 1.57 84.01 ± 1.58
TinyMyo 75.28 ± 0.07 75.01 ± 0.09 21.60 ± 0.51 16.61 ± 0.49 83.67 ± 0.83 83.48 ± 0.93
NeuroRVQ-EMG 90.38 ± 0.04 90.41 ± 0.06 25.54 ± 0.68 21.91 ± 0.81 88.45 ± 1.06 88.45 ± 1.05
Reviewer oEvc · CommentOpenReview ↗

I thank the authors for a substantial and well-targeted rebuttal. I asked for four things and all four were delivered, several of them with new experiments run inside the rebuttal window.

Tokenizer-swap (my Q1, which I said was decisive). The controlled ablation is the right experiment: same backbone, same parameter budget, same pretraining data, same normalisation, same downstream protocol, with only the tokenizer varying (58.5 → 64.0 under full fine-tuning). This directly addresses the confound I raised and I accept it as evidence that tokenizer quality, not scale or data, drives a substantial part of the gain. I agree with the authors that a full five-task version was not feasible in the rebuttal window, and I do not hold that against them; I note Reviewer ZD7f's point that the single domain-matched task limits what can be concluded, and I read the Appendix K comparison as the across-task complement, with the caveat that the backbones there are not identical.

Codebook analysis (Q2). The per-level utilisation, perplexity, dead-code and top-1%-mass tables are exactly what was missing, and the residual-hierarchy interpretation is convincing for EEG and EMG. ECG is a different matter: 49.6% mean utilisation with 4132 dead codes per 8192-entry codebook is a real finding and I would ask you not to file it under "no collapse". The saturation explanation is plausible, but the honest statement is that the ECG configuration is over-provisioned, and it would strengthen the paper to show that a smaller ECG codebook loses nothing downstream.

Frozen-backbone / linear probe (Q2). This was important to me because full fine-tuning cannot separate representation quality from optimisation capacity, and the result is one of the strongest in the rebuttal (EEG mean .687 vs REVE .649, with the Wilcoxon tests you added for Reviewer ZD7f). Please include the significance table in the paper, including the ties on Sleep and Motor.

Reconstruction gap (Q3). Re-running at 0.1–100 Hz, a band that disadvantages your model, and still obtaining 0.142 vs 2.009 removes my concern that the 67× figure was a filtering or normalisation artefact.

Data overlap (Q4). I appreciate that you checked this and disclosed the "Eyes" subject-level leakage rather than leaving it implicit, and that you showed the ranking is unchanged without it. Please keep the no-Eyes table in the paper.

One substantive point for the revision. Your own codebook-count ablation shows that a 10× reduction in tokenizer MSE (0.35 → 0.035) buys only 62.7 → 64.0, while the loss-function swap (0.946 → 0.035) buys 58.5 → 64.0. That is a saturation result, and it does not support the paper's headline framing that tokenizer fidelity is simply "decisive". The defensible claim, which your data does support, is narrower and more interesting: reconstruction fidelity matters sharply up to the point where task-relevant structure is captured, and is largely inert beyond it — which is why the topologically-correct phase loss, not codebook scale, is where the gain comes from. I would ask you to reframe the claim accordingly.

I also continue to think the PTB-XL 5-class result should be presented alongside the 43-class win rather than after it, and I would encourage releasing the code now rather than upon acceptance.

I am raising my Rating from 2 to 4, and Quality and Significance from 2 to 3.

Reviewer EV4YOpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper presents NeuroRVQ, a multi-scale residual vector quantization tokenization method for learning discrete token representations of biosignals, with demonstrations on EEG, ECG, and EMG. With a combination of multi-scale temporal encoding, hierarchical RVQ, and a phase-aware reconstruction loss, it demonstrates improvements in signal reconstruction and downstream performance.

Strengths and weaknesses

strengths:

  • This paper studies an important problem of learning discrete representations for biosignals across multiple modalities
  • scaling analysis shows consistent improvements as the model becomes more complex (codebook, branches, and overall parameter counts)
  • The authors present a good amount of experiments, including EEG, ECG, and EMG, a few downstream tasks, ablations, and comparisons with baselines
  • Notations are clearly defined

weaknesses:

  • The overall method novelty remains somewhat unclear. The framework combines several existing components, including multi-scale architectures, residual vector quantization, Fourier-domain reconstruction, and masked token prediction,
  • The phase-aware loss appears to provide the largest performance gain (Appendix Table 2), while the main proposed contribution is the tokenizer architecture, and phase-aware loss is also well established in signal processing
  • Minor: Figure 1 uses very similar colors, making it difficult to distinguish different components
  • Minor: The font sizes in several figures and tables are too small to read.
Questions
  • The paper emphasizes the different characteristics of each modality. However, Table 6 shows that the architecture and training hyperparameters are almost identical across modalities, except for the number of codebooks and hidden dimension. This is somewhat counterintuitive. Could you clarify whether design choices are modality-dependent
  • The controlled comparisons with LaBraM and BrainOmni help isolate the tokenizer contribution. Additional comparison using the same foundation model backbone with different tokenizers would further strengthen the claims.
  • What is the downstream performance as a function of the number of branches or codebooks?
  • How well are the larger codebooks utilized, i.e. codebook perplexity or token usage distribution?
Limitations

yes

Final justification

Thanks to the authors for the detailed rebuttal.

The additional experiments address most of my concerns, and the phase-aware loss now appears to be the clearest technical contribution, with the added ablation supporting its downstream impact. My remaining reservation is that much of the rest of the framework is an integration and adaptation of existing components, and the same-backbone tokenizer comparison is still between NeuroRVQ variants rather than different tokenizer families.

Overall, the rebuttal is strong and increases my confidence in the paper, but my assessment of the overall contribution remains more moderate. I therefore maintain my score of 4.

Formatting concerns

n/a

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for their positive assessment. In the revised paper, we will add the results described below and we will correct minor presentation issues raised by the reviewer.

Novelty

Prior codebook-based tokenizers, e.g. LaBraM (VQ-VAE), have not achieved faithful biosignal reconstruction. NeuroRVQ tokenizer solves this problem. The novelty is not in the individual building blocks but in their principled design and integration, where each block addresses a specific issue: (a) multi-scale branches based on neuroscientific priors to disentangle frequency bands; (b) per-scale RVQ codebooks (one per frequency branch) to extract fine-details; (c) the phase-aware loss addresses a provable failure mode of raw phase MSE (Appendix A). Critically, existing biosignal tokenizers get this wrong (e.g. LaBraM or BrainOmni) by applying MSE to phase angles, ignoring the circular topology of phase. To our knowledge NeuroRVQ is the first tokenizer to formulate phase reconstruction in a topologically-correct way and with neuroscientific priors. Our contribution is in how the model (and its training) is designed. Appendix B shows that every component of our tokeniser (design and loss) contributes.

Modality Characteristics

As described in Section 4, some parameters of the architecture and input patch must be adapted to each biosignal's spectro-temporal characteristics. For reasons detailed there, we chose fs=200Hz, patch size=1sec for EEG; fs=1000Hz, patch size=200ms for EMG; and fs=200Hz, patch size=200ms for ECG. Reconstruction difficulty scales with signal complexity: ECG (stereotyped, low-noise) is easiest and require fewer codebooks, EEG (richer spectral structure) requires more and broadband EMG (sampled at 1000 Hz) demands the most. Using the Scaling Analysis (Section 4.2) in Section 5 (Evaluation), we deliberately use 4 temporal branches for all modalities, with 8 codebooks per branch for EEG/ECG and 16 for EMG, reflecting the greater demands of broadband EMG (per Section 4.2 scaling analysis and available compute). The reviewer correctly notes that Table 6 lists near-identical values across modalities. This is because Table 6 mostly reports training hyperparameters (learning rate, batch size, optimizer schedule), which we deliberately held constant. The modality-adaptive choices are the signal-level and architectural ones (sampling rate, patch length, number of temporal branches and RVQ depth). We hope this clarifies the distinction between the modality-specific architecture/patching choices and the shared training hyperparameters.

Reconstruction and downstream performance

In Appendix K, we have provided an analysis of two models LaBraM and NeuroRVQ-EEG where both models (as well as their corresponding tokenizers) are pre-trained and fine-tuned on the same datasets and with identical training and fine-tuning regimes. The results of Table 15 (the ERP task was added in the period between submission and the release of reviews) show that NeuroRVQ (which has a better quality tokenizer) achieves better downstream task performance:

Model Motor Memory Sleep Eyes ERP Mean
LaBraM 0.570 0.565 0.715 0.805 0.819 0.695
NeuroRVQ-EEG 0.700 0.573 0.728 0.869 0.876 0.749

Although LaBraM (5.8M) and NeuroRVQ-EEG (5.9M) share similar backbones (temporal encoders + transformers), they differ in the temporal encoder (LaBraM 1 branch vs NeuroRVQ 4) and in pre-training targets (1 vs 4×8 per masked token). So this analysis holds datasets, tokenizer training and pre-training/fine-tuning regimes identical, but the backbones differ slightly.

To examine the effect of same backbone, parameter budget, pretraining data, normalization and downstream protocol within the rebuttal time-frame, we designed the following ablation: We use two tokenizers from Appendix B Table 2 (EEG): Row 2 (4-Branch, 8CB, MSE Phase + MSE A) and Row 5 (4-Branch, 8CB, Phase Loss + log(A) + Temporal), which share the same architecture and differ only in the training loss (val MSE 0.946 and 0.035 respectively). We pre-trained two NeuroRVQ-EEG models on PhysioNet-MI using these two tokenizers and benchmarked both on the High Gamma Motor dataset. We chose Motor because the tokenizers and consequently the foundation models are pre-trained on PhysioNet-MI (a motor dataset), and Motor is the downstream task most closely matched to that pretraining domain. Evaluation is under head-only (10-fold) and full-finetuning (5-fold, due to compute constraints) subject-wise cross-validation. In other words, backbone architecture, parameter budget, pretraining data, normalization and downstream protocol are held identical. Only the tokenizer varies. The results show that tokenization quality translates into downstream performance: balanced accuracy improves with tokenizer fidelity and the effect is clearest under full fine-tuning.

Tokenizer used to train same backbone model (corresponding val MSE) Head-Only Full
4-Branch, 8CB, MSE Phase + MSE A (0.946) 56.5 (8.59) 58.5 (3.19)
4-Branch, 8CB, Phase Loss + log(A) + Temporal (0.035) 58.9 (5.67) 64.0 (1.39)

We extended this ablation study to other tokenizers from Section 4.2 (Figure 2) in the EEG modality. To examine the relationship between number of codebooks and downstream performance, we used the tokenizers with (a) 4-Branch, 1CB (b) 4-Branch, 2CB and (c) 4-Branch, 8CB, which keeps the same architecture and training loss but scales only the number of codebooks.

Tokenizer used to train same backbone model (corresponding val MSE) Head-Only Full
4-Branch, 1CB (0.35) 59.0 (4.91) 62.7 (1.61)
4-Branch, 2CB (0.12) 59.1 (6.09) 63.5 (2.23)
4-Branch, 8CB (0.035) 58.9 (5.67) 64.0 (1.39)

We notice that once the tokenizer faithfully reconstructs task-relevant structure (motor in this case), further fidelity captures detail less relevant to the label with diminishing returns: a 10× MSE reduction (0.35→0.035) yields modest gain (saturation), whereas the low vs very good fidelity loss swap (0.946→0.035) gives a large 58.5→64.0. Under head-only probing the top tokenizers are indistinguishable (58.9–59.1, within across-fold std), while full fine-tuning separates them cleanly.

Codebook Utilization

Codebook utilization is an important property for an RVQ-based tokenizer. Using the held-out validation sets per modality (EEG, ECG, EMG), we computed the following metrics across all branches (4 for all modalities) and RVQ levels (8 for EEG/ECG and 16 for EMG): utilization, perplexity, dead codes, top-1% mass (selection probability captured by the 1% most-used codes).

EEG

RVQ level Utilization Perplexity Dead codes Top-1% mass
1 80.9% 6099 1566 0.039
2 97.1% 7562 234 0.029
3 97.7% 7668 188 0.026
4 99.5% 7815 40 0.025
5 100.0% 7846 3 0.024
6 100.0% 7802 1 0.022
7 99.9% 7748 6 0.021
8 99.8% 7740 18 0.018
Mean 96.9% 7535 257 0.026

ECG

RVQ level Utilization Perplexity Dead codes Top-1% mass
1 29.2% 2060 5798 0.123
2 67.9% 4708 2631 0.068
3 54.3% 3846 3746 0.101
4 47.8% 3408 4280 0.100
5 53.0% 3805 3848 0.085
6 47.0% 3465 4342 0.091
7 47.0% 3544 4338 0.079
8 50.2% 3850 4076 0.060
Mean 49.6% 3586 4132 0.089

EMG

RVQ level Utilization Perplexity Dead codes Top-1% mass
1 88.1% 6442 978 0.053
2 100.0% 7331 1 0.049
3 99.9% 7355 5 0.048
4 100.0% 7388 0 0.046
5 100.0% 7418 2 0.044
6 100.0% 7454 0 0.042
7 100.0% 7488 1 0.039
8 100.0% 7517 0 0.037
9 100.0% 7541 0 0.036
10 100.0% 7568 0 0.035
11 100.0% 7618 0 0.034
12 100.0% 7632 0 0.034
13 100.0% 7733 0 0.032
14 100.0% 7812 0 0.030
15 100.0% 7844 0 0.028
16 100.0% 7913 0 0.027
Mean 99.2% 7503 62 0.038

NeuroRVQ shows efficient code usage with no collapse: EEG and EMG reach 96.9% and 99.2% mean utilization with near-uniform usage and only 257 and 62 dead codes per 8192-entry codebook respectively. Within each modality the coarse first RVQ level has the lowest utilization while deeper residual levels saturate toward 100%, with perplexity increasing and top-code concentration decreasing monotonically with depth. This behavior is a residual hierarchy: first levels produce coarse details and successive levels encode progressively finer detail spread across the full codebook. ECG shows lower utilization (49.6%): this is expected and consistent with our scaling analysis (Section 4.2), which found that ECG's stereotyped spectrally simple morphology saturates with far fewer codebooks than EEG or EMG.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…