potentialpaper

BioMicroAgents: A Co-evolutionary Multi-Agent Framework for High-Fidelity Biomicroscopy Imaging

Yongwei Jiang, Peilin Li, anfu deng, Jun Yin, XiaoyuChen

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. BioMicroAgents is a co-evolving multi-agent framework that formulates biomicro imaging as a memory-driven, feedback-optimized process, achieving artifact-free enhancement with improved sub-cellular fidelity and downstream performance.

Abstract. Biomicroscopy imaging involves the complex coordination of multiple procedures, such as focusing, illumination, and staining. Traditional unitary methods struggle with dynamical environments, while hybrid models pre-trained on natural images tend to introduce artifacts for higher perceptual metrics. Notably, biological imaging is not a one-off task. It is an iterative process similar to human expert’s observation, verification and adjustment. They can benefit from history, remembering which processing strategies are suitable and can also identify issues such as artifacts and mis-staining from verification. To this end, we propose BioMicroAgents, the first multi-agent framework with co-evolutionary capabilities designed to simulate and optimize whole biomicro imaging process including brightening, denoising, deblur, super-resolution, and virtual staining. Through reinforcement learning, the model can reflect based on historical experience to reduce artifacts and mis-staining, while enhancing edge and structural features to improve the accuracy of downstream tasks. Specifically, BioMicroAgents includes: (i) Multi-modal Analytical Agents, which utilize multimodal RAG to provide template images and biomicro knowledge, and employ the memory mechanism to analyze optimal processing paths; (ii) We propose three biomicro fidelity metrics and utilize three agent groups (MicroNavigator, MicroProcessor, and MicroAuthenticator) to perform rigorous analysis, processing, and verification. (iii) Co-evolutionary ability, which achieves dynamic policy and self-correction through interactive feedback strategies and memory mechanisms, allowing the agent to evolve from history and other agents. We test model across 12 biomicro tasks, BioMicroAgents achieved improvements in perceptual quality while adhering to strict fidelity in sub-cellular features. It also enhances the accuracy of downstream tasks such as segmentation and cell counting, showcasing the potential of general-purpose visual agents in bioscience.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
4 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:42 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The paper proposes BioMicroAgents, which reframes microscopy image processing from a one-shot mapping problem as a closed-loop workflow and introduces three biological-fidelity metrics. It reports strong results across super-resolution, virtual staining, low-light enhancement, denoising, and deblurring, and claims improvements in both perceptual quality and downstream tasks such as segmentation and cell counting. Microscopy image processing should preserve biological fidelity rather than optimize perceptual quality alone. Modeling the process as a closed loop of planning, execution, verification, and rollback is therefore well motivated. The experimental scope is broad, covering super-resolution, virtual staining, denoising, deblurring, and low-light enhancement.

The system is highly complex, but the necessity of this complexity is not sufficiently established. Because many mechanisms are introduced simultaneously, it remains unclear which component addresses which failure mode and how the system fails when that component is removed. Despite its substantial engineering effort, the paper provides few clear empirical takeaways. Computational cost is not adequately reported. Given the complexity of the framework, its inference overhead is likely substantial, and the paper should clarify whether the performance gains justify the additional cost and deployment complexity. Morphology overlap, color consistency, and texture similarity capture only partial proxy attributes and do not necessarily establish biological correctness.

Final justification

The authors have addressed the reviewers’ concerns through additional experiments, clearer explanations of the proposed framework, and improved discussions of the method’s limitations. In particular, the authors supplemented the evaluation with additional ablation studies, robustness analysis, and human evaluation to further validate the effectiveness of the proposed multi-agent framework and clarify the necessity of the planning–execution–verification design.

Although the framework still has some limitations, such as system complexity and the need for stronger validation of biological fidelity, I believe this work makes a valuable contribution by demonstrating the potential of agent-based workflows for automating complex microscopy image processing tasks.

Area Chair 7qtq · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The paper proposes BioMicroAgents, which reframes microscopy image processing from a one-shot mapping problem as a closed-loop workflow and introduces three biological-fidelity metrics. It reports strong results across super-resolution, virtual staining, low-light enhancement, denoising, and deblurring, and claims improvements in both perceptual quality and downstream tasks such as segmentation and cell counting. Microscopy image processing should preserve biological fidelity rather than optimize perceptual quality alone. Modeling the process as a closed loop of planning, execution, verification, and rollback is therefore well motivated. The experimental scope is broad, covering super-resolution, virtual staining, denoising, deblurring, and low-light enhancement.

The system is highly complex, but the necessity of this complexity is not sufficiently established. Because many mechanisms are introduced simultaneously, it remains unclear which component addresses which failure mode and how the system fails when that component is removed. Despite its substantial engineering effort, the paper provides few clear empirical takeaways. Computational cost is not adequately reported. Given the complexity of the framework, its inference overhead is likely substantial, and the paper should clarify whether the performance gains justify the additional cost and deployment complexity. Morphology overlap, color consistency, and texture similarity capture only partial proxy attributes and do not necessarily establish biological correctness.

Final justification

The authors have addressed the reviewers’ concerns through additional experiments, clearer explanations of the proposed framework, and improved discussions of the method’s limitations. In particular, the authors supplemented the evaluation with additional ablation studies, robustness analysis, and human evaluation to further validate the effectiveness of the proposed multi-agent framework and clarify the necessity of the planning–execution–verification design.

Although the framework still has some limitations, such as system complexity and the need for stronger validation of biological fidelity, I believe this work makes a valuable contribution by demonstrating the potential of agent-based workflows for automating complex microscopy image processing tasks.

1 comment
Authors · CommentOpenReview ↗

Response to Meta Review

We sincerely thank all reviewers for their valuable comments and constructive suggestions. During the rebuttal stage, we further clarified the implementation details and methodology and provided supplementary experiments. Reviewer 8Et7 expressed recognition of our work and increased the overall score from 4 to 5, while Reviewer PZ5y maintained a score of 5. We again thank the AC and all reviewers. We commit to releasing all project code, experimental configurations, and evaluation scripts upon acceptance of the paper.

Responses to the AC’s Concerns

  1. Necessity of the System Complexity and Contributions of Individual Components: Reviewers PZ5y and 8Et7 both acknowledged our component ablation experiments. In addition, the comparative and supplementary experiments(Rebuttal to PZ5y, Tables 1 and 2) further demonstrate that the benefits of the individual components do not originate from the expert models. Removing co-evolution, RAG, successful memory, or failure memory consistently degrades both biological-fidelity metrics and downstream performance. The performance improvements primarily arise from the closed-loop workflow formed by dynamic planning, rigorous verification, and the two co-evolution strategies.
  2. Computational Overhead and Deployment Complexity: We acknowledge that BioMicroAgents incurs additional computational costs and therefore report the inference time of the RAG, memory, planning, processing, and verification stages separately (Rebuttal to 8Et7, Table 8). Our central argument is that biological microscopy image processing prioritizes fidelity over speed; therefore, efficiency should not be evaluated independently of biological-fidelity requirements. Nevertheless, the computational complexity of our framework remains acceptable. Supplementary experiments further show that, under the same fidelity-verification criteria, artifacts produced by comparative methods trigger more rollbacks and repeated processing, whereas BioMicroAgents reduces such ineffective cycles through its evolutionary mechanisms (Rebuttal to 8Et7, Table 4).
  3. Biological-Fidelity Metrics Cannot Directly Demonstrate Biological Correctness: Most evaluation and optimization metrics and downstream tasks used in our study are widely recognized and valued in biological research, giving them meaningful biological relevance. These metrics capture complementary failure modes overlooked by conventional perceptual-quality metrics. We further conducted expert evaluations involving authenticity discrimination, five-point scoring, and crossover cell counting (Rebuttal to PZ5y, Tables 3–5). Kendall’s (W) ranged from 0.58 to 0.64, while the ICC of the three experts’ mean ratings ranged from 0.86 to 0.90, indicating good consistency among expert evaluations.

Significance and Strengths of the Paper

  1. This paper proposes a unified closed-loop framework for microscopy image processing, formulating the microscopy workflow as a closed-loop process involving planning, execution, verification, rollback, and evolution. It simulates the observation, verification, and adjustment procedures employed by human experts and is fundamentally different from one-shot image mappings and simple unidirectional verifier–executor structures. This contribution was widely recognized by the reviewers.
  2. This paper addresses an important yet long-underappreciated issue: microscopy image processing must preserve biological fidelity rather than pursue perceptual quality alone, a point consistently recognized by the reviewers. Our framework therefore makes biological fidelity a central objective of planning, processing, and verification, rather than merely a post hoc metric, and uses biologically tailored co-evolution mechanisms to continuously improve subsequent processing strategies.
  3. The proposed framework is applicable to multiple microscopy imaging tasks and can be deployed across different scenarios, while also accommodating compound degradations and multi-step processing requests. Moreover, the framework goes beyond solving a single task. It can iteratively improve both imaging quality and biological fidelity in a manner consistent with biological workflows.
  4. The experimental validation is multi-level and complementary, combining perceptual-quality and biological-fidelity metrics, downstream segmentation and counting tasks, component ablations, and independent expert evaluations. This protocol reduces single-metric bias and better reflects the practical requirements of real-world biological microscopy analysis.

Conclusion

We believe that the primary contribution of BioMicroAgents lies in redefining biological microscopy image processing as a closed-loop process that is constrained by biological fidelity and capable of planning, verification, rollback, and evolution. These contributions establish BioMicroAgents as a reliable framework for microscopy image processing. We again thank all reviewers and AC for their evaluation and feedback.

Reviewer 8Et7OpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The authors propose BioMicroAgents, a multi-agent framework that models microscopy image processing as an iterative workflow involving planning, execution, verification, and experience accumulation. The framework consists of three interacting components: MicroNavigator, which uses multimodal retrieval and memory to generate processing plans; MicroProcessor, which dynamically invokes specialized image-processing models; and MicroAuthenticator, which evaluates biological fidelity using morphology-, color-, and texture-based criteria and provides feedback through a reinforcement learning-based co-evolution mechanism. The authors further introduce microscopy-specific fidelity metrics and a memory system that stores successful and failed processing trajectories. The paper evaluates the framework across multiple microscopy restoration and image translation tasks and reports improvements in both image quality and downstream analysis performance, including segmentation and cell counting. The work in general is interesting in topic selection and should be considered for acceptance.

Strengths and weaknesses

The paper tackles an ambitious and practically important problem in biological microscopy imaging: how to coordinate multiple image processing operations, including super-resolution, denoising, deblurring, low-light enhancement, and virtual staining, while preserving biological fidelity. Rather than treating these tasks independently, the authors formulate microscopy image processing as a closed-loop workflow involving planning, execution, verification, rollback, and experience accumulation. To achieve this, they propose BioMicroAgents, a multi-agent framework composed of a planning agent (MicroNavigator), an execution agent (MicroProcessor), and a verification agent (MicroAuthenticator), together with multimodal retrieval, memory, and reinforcement learning-based co-evolution.

A major strength of the paper is its attempt to move beyond single-task image restoration. Biological imaging workflows are often iterative and involve multiple processing stages, making the proposed agent-based formulation conceptually appealing. The integration of retrieval, memory, verification, and rollback mechanisms is well motivated by how human experts interact with microscopy data. I also appreciate the authors' emphasis on biological fidelity rather than solely optimizing perceptual image quality. The proposed fidelity metrics based on morphology, color consistency, and texture authenticity are biologically motivated, and the inclusion of downstream segmentation and cell-counting evaluations is a positive step toward assessing practical utility.

The experimental scope is broad. The framework is evaluated across multiple microscopy tasks and datasets, including super-resolution, virtual staining, denoising, deblurring, and low-light enhancement. Compared with recent image restoration and agentic image-processing methods, the reported results are generally strong, and the ablation studies suggest that both the co-evolution mechanism and memory components contribute to performance improvements.

However, I have several concerns regarding both the technical contribution and the experimental validation.

First, it is often difficult to identify which component is primarily responsible for the observed gains. The proposed framework combines many ingredients simultaneously: multimodal RAG, memory retrieval, planning agents, verification agents, custom fidelity metrics, reinforcement learning, rollback mechanisms, and specialized expert models. While the paper includes component ablations, the overall system is highly complex, making it challenging to disentangle whether the improvements stem from the agentic framework itself or from incorporating stronger underlying image restoration and generation models.

Second, the notion of "co-evolution" appears somewhat overstated. In practice, the interaction largely consists of a verification module providing rewards and feedback to a processing module, together with memory updates that influence future planning. While useful, this resembles a feedback-driven optimization loop more than the stronger notion of co-evolving agent policies. The paper would benefit from a clearer discussion of what distinguishes its formulation from existing agent-verifier or RL-based refinement frameworks.

Third, although the proposed biological fidelity metrics are intuitively reasonable, it remains unclear whether they truly capture biological correctness. Metrics such as color consistency, segmentation overlap, and texture similarity may correlate with image quality, but they do not necessarily guarantee that biologically meaningful structures are preserved. This concern is particularly important for virtual staining and super-resolution tasks, where hallucinated features may appear plausible while being biologically incorrect.

Fourth, the evaluation focuses primarily on image-level metrics and downstream segmentation/counting performance. There is limited evidence that domain experts would prefer the generated results or consider them biologically more trustworthy. Given the paper's emphasis on biological fidelity, some form of expert assessment or biological validation would substantially strengthen the results/claims.

Finally, the framework is computationally heavy and operationally complex. It combines multiple foundation models, retrieval systems, memory mechanisms, and RL-based optimization. The paper does not sufficiently discuss computational costs, deployment complexity, or whether the gains justify the additional system overhead compared to simpler task-specific approaches.

The work presents an ambitious and creative agentic framework tailored to microscopy imaging workflows. The motivation is compelling, the evaluation is extensive, and the idea of integrating planning, memory, verification, and biological constraints is interesting. However, the current presentation does not fully establish that the complexity of the proposed multi-agent system is necessary, nor does it completely validate that the proposed fidelity mechanisms reliably preserve biological correctness. Stronger evidence regarding the unique benefits of the agentic design and more direct biological validation would strengthen the paper considerably.

Questions
  1. Can the authors provide stronger evidence that the agentic framework itself is responsible for the observed gains?

The proposed system combines multiple components, including multimodal RAG, memory, rollback mechanisms, custom fidelity metrics, reinforcement learning, and strong underlying restoration/generation models. While the ablation studies are helpful, it remains difficult to determine which components contribute most to performance improvements. Additional analysis clarifying the relative contribution of the agentic workflow versus the underlying expert models would strengthen the paper.

  1. What distinguishes the proposed co-evolution mechanism from existing agent-verifier or feedback-based optimization frameworks?

The paper repeatedly emphasizes co-evolution between MicroNavigator, MicroProcessor, and MicroAuthenticator. However, the interaction appears largely driven by reward feedback and memory updates. Could the authors clarify the conceptual and empirical differences between their formulation and existing agent-verifier or RL-based refinement frameworks?

  1. How well do the proposed biological fidelity metrics correlate with actual biological correctness?

The proposed metrics (Cellular Morphological Integrity, Chromatographic Consistency, and Histological Texture Authenticity) are biologically motivated and constitute an important part of the framework. However, it remains unclear whether improvements in these metrics correspond to improved biological validity.

  1. Can the authors provide evidence that the generated outputs are preferred by domain experts?

  2. Will the datasets, memory traces, and code be publicly released?

Limitations

The authors acknowledge the limited scale and diversity of the available datasets and note that broader validation remains future work. However, several important limitations are not sufficiently discussed. First, the framework relies on a large number of interacting components, including retrieval systems, memory modules, reinforcement learning, verification metrics, and multiple expert models, yet the computational cost and deployment complexity of the full system are not analyzed. Second, the paper assumes that the proposed biological fidelity metrics correlate with biological correctness, but the limitations of these proxy metrics and their potential failure modes are not discussed. Third, for tasks such as super-resolution and virtual staining, the possibility of generating biologically plausible but incorrect structures should be explicitly acknowledged, particularly if the outputs are intended to support downstream scientific or clinical interpretation. Finally, the paper would benefit from a discussion of reproducibility, including dataset availability and the practical challenges of reproducing a complex multi-agent workflow.

Final justification

After considering the authors' rebuttal and additional experimental results, I have made my recommendation to accept.

-The authors provided extra evidence that the proposed agentic framework, rather than only the underlying foundation models, contributes to the observed performance gains. The additional ablations (e.g., removing key expert models, fixed planning, VLP planning, and Coev.-RL) consistently demonstrate the importance of the collaborative multi-agent design. -The rebuttal clarified how the proposed co-evolution mechanism differs from conventional planner/verifier or feedback-based frameworks. The explanation of the coupled optimization between the navigator and processor, together with the additional rollback analysis, better motivates the proposed design. -My concern regarding biological fidelity was partially addressed. While the proposed metrics remain proxy measures rather than guarantees of biological correctness, the newly provided expert evaluations, Turing test, and downstream validation offer stronger empirical evidence that the generated results are biologically meaningful. -The authors also clarified their plans for releasing the datasets and code and provided additional discussion on computational complexity and deployment trade-offs.

Some limitations remain, including the lack of formal guarantees for biological correctness and the increased computational overhead of the framework. However, these concerns are outweighed by the strengthened empirical validation, the practical relevance of the problem, and the potential impact of the proposed framework. Overall, I believe the revised paper meets the bar for an accept recommendation.

Formatting concerns

NA

4 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for your careful and constructive review. Below, we address each of your concerns.

  1. Can the authors provide stronger evidence that the agentic framework itself is responsible for the observed gains?

Our core insight is to model the professional biological microscopy imaging workflow as a collaborative multi-agent process that emulates how experts iteratively observe, validate, and adjustment. The ablation in Table 7 modify only the workflow mechanisms while keeping the task settings. On the HE virtual staining task, removing RL-based co-evolution decreases CLIPIQA from 0.435 to 0.363 and ACC from 0.895 to 0.883. Removing multimodal RAG decreases ACC from 0.895 to 0.871 and DICE from 0.782 to 0.738. Removing memories likewise degrades the primary biological-fidelity and downstream-task metrics. Furthermore, in the experiment shown in Fig. 5(b), all model parameters were frozen, and memory write-back was disabled during testing. This design disentangles the benefits of historical memory retrieval from those attributable to a stronger parameterized model. The experiment in Fig. 5(a) further demonstrates the effect of the co-evolution process on performance. Notably, some of the strong underlying expert models used in our framework, such as Qwen-VL, were also included in the baseline comparisons, naturally providing an additional ablation-like evaluation. Nevertheless, our full model still achieved superior results, as shown in Tables 1 and 3.

We further conducted an additional ablation study by removing several strong expert models.

Task (IHC2Lap) NIQE ↓ CLIPIQA ↑ SSIM ↑ PSNR ↑ Dice ↑ ACC ↑
-MicroEdit-VS 2.85 0.391 0.910 35.05 0.779 0.892
-MicroEdit-SR 2.87 0.388 0.906 34.94 0.778 0.887
BioMicroAgents 2.81 0.394 0.912 35.12 0.781 0.892

We further provide results from two additional ablation experiments: (i) removing MicroNavigator and applying a fixed plan (FIX); and (ii) using Qwen3-VL to provide prior knowledge of biological microscopy and the plan (VLP).

Task (IHC2Lap) NIQE ↓ CLIPIQA ↑ ACC↑ DICE ↑
FIX 3.56 0.321 0.783 0.694
VLP 3.29 0.351 0.850 0.738
BioMicroAgents 2.81 0.394 0.892 0.781
  1. How does the proposed “co-evolution” mechanism differ from existing verifier- or feedback-based optimization frameworks?

Unlike conventional unidirectional verifier–executor loops that provide only post hoc scores, or isolated reward optimization, BioMicroAgents enables biological-fidelity-driven co-adaptation by jointly optimizing πp\pi_p​ and πn\pi_n​ under rigorous verification. This design mirrors expert workflows and is further tailored to the biological domain (Eq. 6, Fig. 2).

In this work, co-evolution refers to the coupled improvement of different groups of agents. This coupling is achieved through two pathways: (1) MicroAuthenticator converts biological-fidelity evaluations into rewards that are used to optimize the processor policy, πp\pi_p. (2) The feedback—including evaluation scores, failure reasons, erroneous regions, and processing trajectories—is stored as experience and retrieved in subsequent tasks to improve the navigator policy πn\pi_n. The effectiveness of the proposed method is further demonstrated by the ablation studies(tab.7).

Moreover, our additional experiments further demonstrate how our approach differs from existing planner-processer–verifier frameworks.

Task (IHC2Lap) NIQE ↓ CLIPIQA ↑ ACC ↑ DICE ↑
FIX 3.56 0.321 0.783 0.694
VLP 3.29 0.351 0.850 0.738
BioMicroAgents 2.81 0.394 0.892 0.781

We also report the effect of Coev.-RL on the number of rollbacks, as shown below.

with Coev.-RL without Coev.-RL
Rollout 1.12 3.67
  1. Can the proposed biological-fidelity metrics guarantee biological correctness? Are the generated results more favorably evaluated by domain experts?

We agree that the metrics proposed in this work are proxy measures of biological fidelity, however, they are biologically meaningful. They are designed to capture complementary failure modes that conventional perceptual-quality metrics may overlook:

  • HCMIH_{\mathrm{CMI}} evaluates cellular morphological integrity;
  • HCCH_{\mathrm{CC}} evaluates staining consistency
  • HHTAH_{\mathrm{HTA}} evaluates the histological textures.

During validation, these metrics are combined with perceptual-quality measures and downstream segmentation and cell-counting results, since visually plausible outputs may still alter cell boundaries, hallucinate subcellular textures, or distort biologically meaningful staining patterns. Such downstream validation is well established and widely used in prior studies (e.g., [13, 14]).

We conducted additional evaluations involving independent human experts and report the corresponding rating-scale statistics to further validate our experimental findings.

Turing Test:

Expert Real (90) SwinIR (30) 4KAgent (30) BioMicroAgents (30) Sensitivity Overall Accuracy
1 27/90 21/30 29/30 16/30 0.733 0.717
2 6/90 12/30 28/30 7/30 0.522 0.728
3 42/90 17/30 30/30 9/30 0.622 0.578
AI Pass Rate – 0.444 0.033 0.644 – –
Standard Deviation – 0.150 0.033 0.158 – –

Scoring evaluation: The scoring rubric evaluates the images across three dimensions: image quality, artifacts, and usefulness for biological assessment. Each dimension is rated on a scale from 1 to 5.

Expert Scoring Rubric DiffBIR + ImageEdit (50) 4KAgent + ImageEdit (50) BioMicroAgents (50)
1 Quality 3.68/0.59 3.92/0.28 4.24/0.23
Artifact 2.86/0.33 3.10/0.30 4.08/0.32
Constructiveness 2.94/0.63 3.52/0.54 4.10/0.30
2 Q 3.86/0.34 3.74/0.69 4.36/0.24
A 3.08/0.32 2.94/0.34 4.20/0.26
C 3.28/0.74 3.16/0.63 4.34/0.23
3 Q 3.58/0.78 4.02/0.26 4.18/0.35
A 2.64/1.09 3.26/0.48 3.98/0.43
C 2.82/0.76 3.70/0.62 4.06/0.38

Swap experiment: Experts were divided into AB groups to count cells in either original or AI images, and accuracy was calculated. The groups then switched conditions and evaluated unseen slides to avoid bias from prior exposure.

Expert Origin 4KAgent ImageEdit DiffBIR + ImageEdit 4KAgent + ImageEdit BioMicroAgents
A-B 0.787 0.715 0.812 0.627 0.684 0.823
B-A 0.776 0.683 0.793 0.632 0.688 0.830
  1. Will the datasets, memory traces, and code be publicly released?

Yes. Most of the datasets used in our experiments are publicly available, and the manuscript reports the dataset splits and computational environments for the different tasks.The AppendixB also provides the main configurations of the RAG and memory. A mini version of the proposed MicroBrighten dataset has been submitted as supplementary material, and its scale and composition are described in the appendix. The complete version will be released subsequently.

  1. Computational and deployment complexity

RAG, memory, and rigorous verifier-based fidelity checks introduce additional computational overhead compared with conventional multi-agent methods such as 4KAgent (106.31 s). However, microscopy image processing prioritizes fidelity over efficiency, and reducing cost at the expense of artifacts is unacceptable, as shown in Appendix D. For 4× tasks, with each workflow including a valid virtual-staining step, we performed inference on an NVIDIA PRO 6000 GPU:

Model MircoNavigator MircoProcessor MircoAuthenticator Total
Component RAG Mem Plan Process Verify
Time(s) 51.32 23.74 16.96 35.63 12.58 140.2

When biological-fidelity metrics are used for verification, 4KAgent triggers frequent artifact-induced rollbacks, increasing computational complexity. Our method reduces these repeated rollbacks and achieves more efficient inference under the same fidelity requirements.

Authors · CommentOpenReview ↗

Experimental design for human expert evaluation

The experimental setup is summarized in the table below. All participating experts had relevant professional experience or held a doctoral degree in a related field. None were authors of this paper, and they had no prior knowledge of the methods evaluated in this study.

Turing Test: Experts were asked to determine whether each image was AI-generated.

Scoring evaluation: The scoring rubric evaluates the images across three dimensions: image quality, artifacts, and usefulness for biological assessment. Each dimension is rated on a scale from 1 to 5.

(1) Quality (Image Quality)

Evaluate only the visual quality of the image, without considering whether the biological content depicted is accurate or realistic. The assessment should mainly consider noise, blur caused by camera defocus or motion, insufficient illumination, inadequate contrast, and low resolution.

  • Score 1 — Poor: The image contains severe noise, blur, insufficient illumination, or inadequate resolution. Key structures are difficult to identify, substantially hindering observation and evaluation.
  • Score 2 — Fair: The image has noticeable quality problems. Some structures remain identifiable, but noise, blur, illumination, or resolution issues still significantly affect observation.
  • Score 3 — Moderate: The image is generally interpretable, and the main structures are reasonably clear. However, some noise, blur, uneven illumination, or loss of detail remains.
  • Score 4 — Good: The image has good clarity and contrast. Only minor noise, blur, or resolution limitations are present, without affecting the observation of major structures and details.
  • Score 5 — Excellent: The image is clear and rich in detail, with appropriate illumination and contrast. There is almost no perceptible noise, blur, or resolution-related degradation.

(2) Artifact

Evaluate whether the image contains artifacts, unexpected textures, excessive enhancement, or excessive denoising that may interfere with observation and assessment.

  • Score 1 — Severe: The image contains numerous artifacts or abnormal textures that interfere with evaluation, or shows severe over-enhancement or over-denoising, resulting in obvious structural distortion.
  • Score 2 — Noticeable: The image contains multiple artifacts or abnormal textures that interfere with evaluation. Enhancement or denoising has affected the reliability of some structures.
  • Score 3 — Moderate: The image contains some artifacts, abnormal textures, enhancement, or denoising that may affect evaluation. However, some of these issues are also difficult to distinguish in the original image based on the evaluator’s knowledge and experience.
  • Score 4 — Minor: The image contains essentially no obvious artifacts or abnormal textures that affect evaluation. Any enhancement or denoising is difficult to detect, and the results are generally consistent with the evaluator’s knowledge, experience, and personal assessment.
  • Score 5 — No noticeable issues: The image contains no identifiable artifacts, abnormal textures, or inappropriate processing. The enhancement and denoising results are highly consistent with the evaluator’s relevant knowledge and experience.

(3) Constructiveness (Usefulness for Biological Assessment)

Evaluate whether the image facilitates biological assessment or further research, including but not limited to cell counting, cell segmentation, morphological observation, and quantitative analysis.

  • Score 1 — Not useful at all: The image does not support biological assessment and may even be misleading or make interpretation more difficult.
  • Score 2 — Mostly not useful: The image provides no noticeable improvement compared with direct observation of the original image.
  • Score 3 — Somewhat useful: The image improves the visibility of some structures or details and provides limited assistance for biological observation or analysis.
  • Score 4 — Highly useful: The image clearly presents most structures and details relevant to the assessment and facilitates cell counting, segmentation, morphological observation, or other biological analyses.
  • Score 5 — Extremely useful: The image substantially improves the visibility and interpretability of relevant structures and details, reliably supporting cell counting, segmentation, quantitative analysis, or other further analyses.

Swap experiment: Experts performed cell-counting tasks on different slides, and their counts were compared with the ground-truth values. To prevent prior exposure to the original slides from influencing the evaluation of the AI-processed slides, the experts were divided into two groups: Group A counted cells in the original images, while Group B counted cells in the AI-processed images. The two groups then switched tasks and performed cell counting on another set of previously unseen slides.

Reviewer 8Et7 · CommentOpenReview ↗

The authors have addressed my main concerns and provided helpful clarifications. I appreciate your careful engagement with the review process.

Authors · CommentOpenReview ↗

Thank you very much for your careful review of our paper and your constructive feedback. Regardless of the outcome, we will continue to improve our work. We wish you all the best.

Reviewer pZ5yOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
4/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This work proposes BioMicroAgents, a multi-agent framework for simulating and optimizing biomicroscopy imaging workflows. Inspired by the iterative observation and verification process of human experts, the framework employs three agent groups—MicroNavigator, MicroProcessor, and MicroAuthenticator—to perform planning, processing, and verification, respectively. Through reinforcement learning, memory mechanisms, and interactive feedback, the agents can adapt processing strategies and reduce artifacts over time. Experimental results across multiple biomicro imaging tasks demonstrate improvements in image quality, biological fidelity, and downstream analysis performance.

Strengths and weaknesses

This paper proposes BioMicroAgents, a multi-agent framework for simulating and optimizing biomicroscopy imaging workflows. The framework employs three agent groups—MicroNavigator, MicroProcessor, and MicroAuthenticator—to perform planning, processing, and verification, respectively. Through reinforcement learning, memory mechanisms, and interactive feedback, the agents iteratively improve imaging quality and biological fidelity across a wide range of biomicro imaging tasks. The work addresses an important and practical problem in biological imaging, where traditional single-stage approaches often struggle to adapt to complex and dynamic imaging conditions. A key strength of the work is the formulation of biomicro imaging as a collaborative multi-agent process that mimics the observation, verification, and adjustment workflow used by human experts. The integration of memory, feedback, and co-evolutionary learning mechanisms is well motivated and provides a coherent framework for iterative image enhancement and analysis. The paper is generally clear, and the proposed architecture is intuitive despite its complexity. These results from 12 datasets suggest that the framework is broadly applicable across diverse imaging scenarios. While additional analysis of component contributions and computational efficiency would further strengthen the work, I find the problem formulation, methodological design, and empirical validation to be compelling. Overall, this paper presents a meaningful and potentially impactful contribution to AI for biological imaging

Questions
  • Since the work demonstrates the effectiveness of multimodal RAG, co-evolution, and memory mechanisms through ablation studies. Could the authors further discuss the individual roles of MicroNavigator, MicroProcessor, and MicroAuthenticator, and whether certain agents contribute more significantly to performance gains than others?
  • Such a proposed BioMicroAgents framework is evaluated across 12 biomicro imaging tasks. Are there specific task types or imaging scenarios where BioMicroAgents is less effective, and what are the primary failure modes observed in practice?
  • This work introduces biomicro fidelity metrics to evaluate biological consistency. Could the authors provide additional discussion of how these metrics correlate with expert biological assessment, or whether they generalize across imaging modalities?
  • The co-evolutionary mechanism appears to be a key contribution of the framework. Could the authors provide additional qualitative examples illustrating how agent behavior evolves and how historical memory influences decision-making?
Limitations

Yes

Formatting concerns

No Formatting Concerns

4 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for your positive assessment of our work and for raising these constructive questions. We address your questions one by one.

  1. Could the authors further discuss the roles of Navigator, Processor, and Authenticator, and whether certain agents contribute more significantly to performance gains than others?

    The three agent groups perform complementary rather than interchangeable functions. MicroNavigator integrates user requirements, microscopy-domain knowledge, staining templates, and memories of both successful and failed cases to determine which operations should be performed and in what order. MicroProcessor dynamically schedules task-relevant expert models to determine how the selected operations should be executed. MicroAuthenticator evaluates cellular morphology, staining consistency, and histological texture to determine whether the output of each step satisfies the biological requirements, triggering rollback or providing rewards for policy updates when necessary. Therefore, MicroAuthenticator not only directly affects the processor policy πp\pi_p, but also influences the subsequent navigator policy πn\pi_n through memory-based feedback.

    MicroNavigator is particularly important for compound degradations and complex processing requests; MicroAuthenticator plays a more prominent role in tasks sensitive to biological fidelity, such as virtual staining and high-magnification super-resolution; and MicroProcessor provides the underlying image-processing capabilities. Table 7 shows that the results of removing reinforcement-learning-based co-evolution, RAG, successful-case memory, or failure-case memory. For example, on the Lap dataset, removing Coev.-RL, RAG, successful-case memory (E+E^+), and failure-case memory (E−E^-) changed NIQE from 2.81 to 3.23, 2.74, 3.05, and 3.18, respectively; decreased CLIPIQA from 0.394 to 0.341, 0.403, 0.352, and 0.331; decreased ACC from 0.892 to 0.879, 0.871, 0.882, and 0.878; and decreased Dice from 0.781 to 0.772, 0.738, 0.772, and 0.768.

    To address your question more directly, we further conducted two additional ablation experiments:(i) We removed MicroNavigator and applied a fixed processing pipeline to all images (FIX).(ii) We replaced MicroNavigator with Qwen3-VL, which directly generated biological microscopy priors and planned the processing workflow (VLP). The results are presented in the table below.

Task (IHC2Lap) NIQE ↓ CLIPIQA ↑ ACC ↑ DICE ↑
FIX 3.56 0.321 0.783 0.694
VLP 3.29 0.351 0.850 0.738
BioMicroAgents 2.81 0.394 0.892 0.781

In the comparative experiments, comparisons with individual strong expert models already demonstrate the contributions of our agentic framework and co-evolution mechanism (Tables 1–3). We further conducted an additional ablation study by removing several strong expert models from the expert pool and evaluating the resulting framework performance.

Task (IHC2Lap) NIQE ↓ CLIPIQA ↑ SSIM ↑ PSNR ↑ Dice ↑ ACC ↑
-MicroEdit-VS 2.85 0.391 0.910 35.05 0.779 0.892
-MicroEdit-SR 2.87 0.388 0.906 34.94 0.778 0.887
BioMicroAgents 2.81 0.394 0.912 35.12 0.781 0.892
  1.  Are there specific task types or imaging scenarios where BioMicroAgents is less effective, and what are the primary failure modes observed in practice?

    BioMicroAgents does not achieve improvements of the same magnitude across all datasets and evaluation metrics. For example, on the IHC dataset, BioMicroAgents improves PSNR by only 0.5 dB compared with 4KAgent. The improvements in perceptual metrics are also relatively modest, with NIQE decreasing by 0.15 and CLIPIQA increasing by 0.007. However, this reflects the multi-objective nature of our method: rather than optimizing a single similarity metric, we balance perceptual quality, structural preservation, staining consistency, and downstream analysis performance.

    The main challenging scenarios observed thus far include:

    1. Extremely severe image degradation. When biological structures have already been irreversibly lost from the original data, they cannot be reliably recovered. Such cases are relatively rare and occur mainly under artificially introduced severe degradations, such as the extreme 8× downsampling results reported in Table XX.

    2. Insufficient information for cross-stain translation. This is a well-recognized limitation in virtual staining: one staining modality may not contain the information required to infer another staining modality. In such cases, MicroNavigator identifies the request as infeasible and refuses to include it as an executable task in the processing plan.

  2. Could the authors provide additional discussion of how these metrics correlate with expert biological assessment, or whether they generalize across imaging modalities?

    We fully agree that this is an important question. We therefore conducted additional evaluations involving independent human experts and report the corresponding rating-scale statistics to further validate our experimental findings. The experimental setup is summarized in the table below. All participating experts had relevant professional experience or held a doctoral degree in a related field. None were authors of this paper, and they had no prior knowledge of the methods evaluated in this study. Due to space limitations, please allow us to provide the experimental details in a subsequent comment.

Turing Test: Experts were asked to determine whether each image was AI-generated.

Expert Real (90) SwinIR (30) 4KAgent (30) BioMicroAgents (30) Sensitivity Overall Accuracy
1 27/90 21/30 29/30 16/30 0.733 0.717
2 6/90 12/30 28/30 7/30 0.522 0.728
3 42/90 17/30 30/30 9/30 0.622 0.578
AI Pass Rate – 0.444 0.033 0.644 – –
Standard Deviation – 0.150 0.033 0.158 – –

Scoring evaluation: The scoring rubric evaluates the images across three dimensions: image quality, artifacts, and usefulness for biological assessment. Each dimension is rated on a scale from 1 to 5.

Expert Scoring Rubric DiffBIR + ImageEdit (50) 4KAgent + ImageEdit (50) BioMicroAgents (50)
1 Quality 3.68/0.59 3.92/0.28 4.24/0.23
Artifact 2.86/0.33 3.10/0.30 4.08/0.32
Constructiveness 2.94/0.63 3.52/0.54 4.10/0.30
2 Quality 3.86/0.34 3.74/0.69 4.36/0.24
Artifact 3.08/0.32 2.94/0.34 4.20/0.26
Constructiveness 3.28/0.74 3.16/0.63 4.34/0.23
3 Quality 3.58/0.78 4.02/0.26 4.18/0.35
Artifact 2.64/1.09 3.26/0.48 3.98/0.43
Constructiveness 2.82/0.76 3.70/0.62 4.06/0.38

Swap experiment: Experts were divided into AB groups to count cells in either original or AI images, and accuracy was calculated. The groups then switched conditions and evaluated unseen slides to avoid bias from prior exposure.

Expert Origin 4KAgent ImageEdit DiffBIR + ImageEdit 4KAgent + ImageEdit BioMicroAgents
A-B 0.787 0.715 0.812 0.627 0.684 0.823
B-A 0.776 0.683 0.793 0.632 0.688 0.830
  1. Could the authors provide additional qualitative examples illustrating how agent behavior evolves and how historical memory influences decision-making?

    Figure 5 quantitatively illustrates how the reward and memory change throughout the co-evolution process. As co-evolution progresses, non-biological artifacts are gradually reduced and structural information is enhanced (Fig. 5a). The memory-evolution experiment with frozen model parameters disentangles the benefits of retrieving historical experience from those arising from model parameter updates (Fig. 5b). In addition, Appendix C demonstrates how successful and failed memories influence agent behavior: the model can retrieve similar cases, adopt corresponding successful strategies, and avoid repeating previously failed approaches.

    We agree that explicitly presenting the decision trajectories would make this mechanism more intuitive. Therefore, we have added visualizations of the evolutionary process to the revised manuscript.

Authors · CommentOpenReview ↗

Experimental design for human expert evaluation

The experimental setup is summarized in the table below. All participating experts had relevant professional experience or held a doctoral degree in a related field. None were authors of this paper, and they had no prior knowledge of the methods evaluated in this study.

Turing Test: Experts were asked to determine whether each image was AI-generated.

Scoring evaluation: The scoring rubric evaluates the images across three dimensions: image quality, artifacts, and usefulness for biological assessment. Each dimension is rated on a scale from 1 to 5.

(1) Quality (Image Quality)

Evaluate only the visual quality of the image, without considering whether the biological content depicted is accurate or realistic. The assessment should mainly consider noise, blur caused by camera defocus or motion, insufficient illumination, inadequate contrast, and low resolution.

  • Score 1 — Poor: The image contains severe noise, blur, insufficient illumination, or inadequate resolution. Key structures are difficult to identify, substantially hindering observation and evaluation.
  • Score 2 — Fair: The image has noticeable quality problems. Some structures remain identifiable, but noise, blur, illumination, or resolution issues still significantly affect observation.
  • Score 3 — Moderate: The image is generally interpretable, and the main structures are reasonably clear. However, some noise, blur, uneven illumination, or loss of detail remains.
  • Score 4 — Good: The image has good clarity and contrast. Only minor noise, blur, or resolution limitations are present, without affecting the observation of major structures and details.
  • Score 5 — Excellent: The image is clear and rich in detail, with appropriate illumination and contrast. There is almost no perceptible noise, blur, or resolution-related degradation.

(2) Artifact

Evaluate whether the image contains artifacts, unexpected textures, excessive enhancement, or excessive denoising that may interfere with observation and assessment.

  • Score 1 — Severe: The image contains numerous artifacts or abnormal textures that interfere with evaluation, or shows severe over-enhancement or over-denoising, resulting in obvious structural distortion.
  • Score 2 — Noticeable: The image contains multiple artifacts or abnormal textures that interfere with evaluation. Enhancement or denoising has affected the reliability of some structures.
  • Score 3 — Moderate: The image contains some artifacts, abnormal textures, enhancement, or denoising that may affect evaluation. However, some of these issues are also difficult to distinguish in the original image based on the evaluator’s knowledge and experience.
  • Score 4 — Minor: The image contains essentially no obvious artifacts or abnormal textures that affect evaluation. Any enhancement or denoising is difficult to detect, and the results are generally consistent with the evaluator’s knowledge, experience, and personal assessment.
  • Score 5 — No noticeable issues: The image contains no identifiable artifacts, abnormal textures, or inappropriate processing. The enhancement and denoising results are highly consistent with the evaluator’s relevant knowledge and experience.

(3) Constructiveness (Usefulness for Biological Assessment)

Evaluate whether the image facilitates biological assessment or further research, including but not limited to cell counting, cell segmentation, morphological observation, and quantitative analysis.

  • Score 1 — Not useful at all: The image does not support biological assessment and may even be misleading or make interpretation more difficult.
  • Score 2 — Mostly not useful: The image provides no noticeable improvement compared with direct observation of the original image.
  • Score 3 — Somewhat useful: The image improves the visibility of some structures or details and provides limited assistance for biological observation or analysis.
  • Score 4 — Highly useful: The image clearly presents most structures and details relevant to the assessment and facilitates cell counting, segmentation, morphological observation, or other biological analyses.
  • Score 5 — Extremely useful: The image substantially improves the visibility and interpretability of relevant structures and details, reliably supporting cell counting, segmentation, quantitative analysis, or other further analyses.

Swap experiment: Experts performed cell-counting tasks on different slides, and their counts were compared with the ground-truth values. To prevent prior exposure to the original slides from influencing the evaluation of the AI-processed slides, the experts were divided into two groups: Group A counted cells in the original images, while Group B counted cells in the AI-processed images. The two groups then switched tasks and performed cell counting on another set of previously unseen slides.

Reviewer pZ5y · CommentOpenReview ↗

Thank you for your detailed response. My primary concern is the reproducibility of the model, considering its complex architecture and the fact that the source code for the project has not been released.

Authors · CommentOpenReview ↗

Thank you again for your recognition and valuable comments. We also attach great importance to reproducibility and practical applicability. We have reported the parameters and system prompts for most components in Appendices B, C, and D, and have submitted part of our currently private data in the supplementary materials. We commit to publicly releasing all private data used in this work, together with the model weights and source code, upon acceptance. Regardless of the final decision, we sincerely hope that you will continue to follow our work.

Reviewer moa1OpenReview ↗
Rating
2/6
Confidence
5/5
Quality
2/4
Clarity
1/4
Significance
2/4
Originality
2/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper proposes BioMicroAgents, a multi-agent microscopy image-processing framework with planning, RAG, memory, expert model routing, verification, rollback, and RL-style co-evolution. It targets many tasks.

Strengths and weaknesses

Strength:

  1. Microscopy image processing does need biological fidelity, not just perceptual quality.
  2. The closed-loop framing of planning → processing → verification → rollback is reasonable.

Weakness:

  1. The paper is organized and written badly:
  • The method is a large system assembled from many existing models, agents, RAG, memory, segmentation, reward models, diffusion/RL, and expert modules. It is very hard to tell what is actually new and what is simply orchestration.
  • The method part is hard to read with too many unnecessary symbols
  • The introduction has 0 references
  • Many grammatical issues, unclear equations, inconsistent notation, and broad claims like “self-evolving” without enough support.
  1. The metrics in MicroAuthenticator heavily depend on the accuracy of the segmentation model; what if OOD data for the segmentation model comes in? The Co-evolution will be guided by wrong rewards. The author also doesn't mention the details of the segmentation model in this part
  2. What is the exact prompt/RAG/memory content used for each task?
  3. I believe the whole system will be extremely hard to reproduce since we need to build all the RAG, memory, template, and co-evolution before getting the result.
  4. The author built a large, complicated system with minimal improvement on some datasets that are not worth such a complicated system.

Overall, the author wants to build all, but I don't think microscopy image enhancement tasks need such a large and complicated system... Maybe planning + a list of + metrics models is enough. In microscopy, without enough data support, a complicated system may lead to overfitting.

Questions

See above

Limitations

See above

Final justification

My final score is still 2 since I'm still worry about applying such a complicated system to the microscopy image enhancement task with minimal performance improvement (maybe it can be achieved with a much clean and smaller agent system). The author do not provide evidence on how each proposed element helps the task, such as a template, co-evolution.

The author addresses my minimal concerns but leaves the major concern unsolved. So I would like to keep my score.

Formatting concerns

No

6 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Thank you for your thoughtful and constructive feedback, we address your comments below.

  1. Contribution goes beyond orchestrating existing components and “self-evolving” without enough support

Our key innovations are articulated in the main text(Points 1 and 2 of the Conbtribution in Introduction), and Reviewer pZ5y also acknowledged that “The integration of memory, feedback, and co-evolutionary learning mechanisms is well motivated .” Our core insight is to model the professional biological microscopy imaging workflow as a collaborative multi-agent process that emulates how experts iteratively observe, validate, and adjustment. Specifically, the agents are not isolated but co-evolve as they process data. Unlike conventional unidirectional verifier–executor loops that provide only post hoc scores, or isolated reward optimization, BioMicroAgents enables biological-fidelity-driven co-adaptation by jointly optimizing πp\pi_p​ and πn\pi_n​ under rigorous verification. This design mirrors expert workflows and is further tailored to the biological domain (Eq. 6, Fig. 2).

We demonstrate these contributions through comparative and ablation studies. Our comparisons include single-agent frameworks and strong expert models, particularly 4KAgent (NeurIPS 2025), with both methods evaluated on several shared datasets. The ablations remove the main components related to your concern and confirm the effectiveness of our self-evolution mechanism. On the Lap, removing Coev.RL, and Memory (E+/E−E^+/E^-) increased NIQE from 2.81 to 3.23, 3.05, and 3.18;decreased CLIPIQA from 0.394 to 0.341, 0.352, and 0.331; decreased ACC from 0.892 to 0.879, 0.882, and 0.878; and decreased DICE from 0.781 to 0.772, 0.772, and 0.768. Fig5 and Tab7 further show progressive improvements in biological-fidelity metrics and downstream performance across evolutionary stages, consistent with Reviewer 8Et7’s observation. We will also add stage-wise qualitative visualizations in the final version to address any remaining concerns.

We further provide results from two additional ablation experiments(IHC2Lap): (i) removing MicroNavigator and applying a fixed plan (FIX); and (ii) using Qwen3-VL to provide prior knowledge of biological microscopy and the plan (VLP).

NIQE ↓ CLIP ↑ ACC ↑ DICE ↑
FIX 3.56 0.321 0.783 0.694
VLP 3.29 0.351 0.850 0.738
ours 2.81 0.394 0.892 0.781

We also report the effect of Coev.-RL on the number of rollbacks, as shown below.

with Coev.-RL without Coev.-RL
Rollout 1.12 3.67

In the comparative experiments, comparisons with individual strong expert models already demonstrate the contributions of our agentic framework and co-evolution (Tab 1–3). We further conducted an additional ablation study by removing strong expert models and evaluating the resulting framework performance.

Task (IHC2Lap) NIQE ↓ CLIP ↑ SSIM ↑ PSNR ↑ Dice ↑ ACC ↑
-MicroEdit-VS 2.85 0.391 0.910 35.05 0.779 0.892
-MicroEdit-SR 2.87 0.388 0.906 34.94 0.778 0.887
ours 2.81 0.394 0.912 35.12 0.781 0.892

These results indicate that our framework is not heavily dependent on the performance of individual strong expert models.

  1. Segmentation Model and OOD Data

Segmentation is not a bottleneck in our task. We use a fine-tuned SAM3 model, and because we have established a unified data interface using Pydantic, the current segmentation module can be flexibly replaced.

To address the OOD concern, we evaluated our model on diverse biological microscopy datasets spanning different tissues, cell types, imaging modalities, staining, degradation types, and acquisition conditions. We believe that the commonly used types in the biological domain have already been covered. As noted in the Conclusion (Section 5), we are collaborating to collect dataset and establish a test set. It currently contains 112 Masson stained tissue images of the murine glenohumeral joint, with results.

Task Metric AgenticIR 4KAgent BioMicroAgents
SR4X SSIM ↑ 0.79 0.82 0.86
PSNR ↑ 30.63 31.02 31.87
NIQE ↓ 4.35 4.08 3.56
CLIP ↑ 0.34 0.38 0.44
Denoise SSIM ↑ 0.86 0.86 0.91
PSNR ↑ 34.94 35.12 35.96
NIQE ↓ 2.89 2.84 2.35
CLIP ↑ 0.37 0.39 0.47
Deblur SSIM ↑ 0.85 0.88 0.92
PSNR ↑ 33.72 34.29 35.34
NIQE ↓ 3.24 3.28 2.67
CLIP ↑ 0.38 0.37 0.46

Although Masson is absent from the training set, BioMicroAgents can leverage RAG to improve performance. These additional results do not alter the main design or conclusions.

  1. Microscopy image may not warrant such a complex system,the improvements are negligible

Microscopy image processing and evaluation are complex and time-consuming. Traditional workflows often rely on repeated acquisition or manual extraction of usable regions, causing substantial waste[13,14]. Tasks such as super-resolution and multi-stain virtual staining have proven beneficial for downstream biological analysis and are inherently interconnected. Therefore, processing them independently and without supervision is inefficient, unsafe, and burdensome for experts. Although the improvements in some perceptual metrics are limited, we achieve strong performance on biologically relevant downstream tasks accepted by domain experts [13], consistent with our design principle.

We have added comparative experiments involving human experts, together with questionnaire-based statistical analyses, to further validate the effectiveness of our method. Due to the word limit, We will provide the detailed design later.

Turing Test:

Expert Real (90) SwinIR (30) 4KAgent (30) BioMicroAgents (30) Sensitivity Overall Accuracy
1 27/90 21/30 29/30 16/30 0.733 0.717
2 6/90 12/30 28/30 7/30 0.522 0.728
3 42/90 17/30 30/30 9/30 0.622 0.578
AI Pass Rate – 0.444 0.033 0.644 – –
Standard Deviation – 0.150 0.033 0.158 – –

Scoring evaluation: The scoring rubric evaluates the images across three dimensions: image quality, artifacts, and usefulness for biological assessment. Each dimension is rated on a scale from 1 to 5.

Expert Scoring Rubric DiffBIR + ImageEdit (50) 4KAgent + ImageEdit (50) BioMicroAgents (50)
1 Quality 3.68/0.59 3.92/0.28 4.24/0.23
Artifact 2.86/0.33 3.10/0.30 4.08/0.32
Constructiveness 2.94/0.63 3.52/0.54 4.10/0.30
2 Q 3.86/0.34 3.74/0.69 4.36/0.24
A 3.08/0.32 2.94/0.34 4.20/0.26
C 3.28/0.74 3.16/0.63 4.34/0.23
3 Q 3.58/0.78 4.02/0.26 4.18/0.35
A 2.64/1.09 3.26/0.48 3.98/0.43
C 2.82/0.76 3.70/0.62 4.06/0.38

Swap experiment: Experts were divided into AB groups to count cells in either original or AI images, and accuracy was calculated. The groups then switched conditions and evaluated unseen slides to avoid bias from prior exposure.

Expert Origin 4KAgent ImageEdit DiffBIR + ImageEdit 4KAgent + ImageEdit BioMicroAgents
A-B 0.787 0.715 0.812 0.627 0.684 0.823
B-A 0.776 0.683 0.793 0.632 0.688 0.830
  1. Unclear notation, grammatical errors and Introduction without ref

Thank you for your careful and thorough review. We revised the manuscript to correct grammatical and spelling errors, improved the presentation and descriptions of the equations in the Methods section, and added the necessary equations and notation to the revised Fig. 1 for clearer understanding. We also added the relevant citations in the Related Work section for the content discussed in the Introduction.

  1. Reproduce and the specific prompts

BioMicroAgents does not rely on any inaccessible proprietary components. The appendix B/D provides more details. The prompts are provided in Appendix C. We commit to releasing the code publicly upon acceptance.

Authors · CommentOpenReview ↗

Experimental design for human expert evaluation

The experimental setup is summarized in the table below. All participating experts had relevant professional experience or held a doctoral degree in a related field. None were authors of this paper, and they had no prior knowledge of the methods evaluated in this study.

Turing Test: Experts were asked to determine whether each image was AI-generated.

Scoring evaluation: The scoring rubric evaluates the images across three dimensions: image quality, artifacts, and usefulness for biological assessment. Each dimension is rated on a scale from 1 to 5.

(1) Quality (Image Quality)

Evaluate only the visual quality of the image, without considering whether the biological content depicted is accurate or realistic. The assessment should mainly consider noise, blur caused by camera defocus or motion, insufficient illumination, inadequate contrast, and low resolution.

  • Score 1 — Poor: The image contains severe noise, blur, insufficient illumination, or inadequate resolution. Key structures are difficult to identify, substantially hindering observation and evaluation.
  • Score 2 — Fair: The image has noticeable quality problems. Some structures remain identifiable, but noise, blur, illumination, or resolution issues still significantly affect observation.
  • Score 3 — Moderate: The image is generally interpretable, and the main structures are reasonably clear. However, some noise, blur, uneven illumination, or loss of detail remains.
  • Score 4 — Good: The image has good clarity and contrast. Only minor noise, blur, or resolution limitations are present, without affecting the observation of major structures and details.
  • Score 5 — Excellent: The image is clear and rich in detail, with appropriate illumination and contrast. There is almost no perceptible noise, blur, or resolution-related degradation.

(2) Artifact Evaluate whether the image contains artifacts, unexpected textures, excessive enhancement, or excessive denoising that may interfere with observation and assessment.

  • Score 1 — Severe: The image contains numerous artifacts or abnormal textures that interfere with evaluation, or shows severe over-enhancement or over-denoising, resulting in obvious structural distortion.
  • Score 2 — Noticeable: The image contains multiple artifacts or abnormal textures that interfere with evaluation. Enhancement or denoising has affected the reliability of some structures.
  • Score 3 — Moderate: The image contains some artifacts, abnormal textures, enhancement, or denoising that may affect evaluation. However, some of these issues are also difficult to distinguish in the original image based on the evaluator’s knowledge and experience.
  • Score 4 — Minor: The image contains essentially no obvious artifacts or abnormal textures that affect evaluation. Any enhancement or denoising is difficult to detect, and the results are generally consistent with the evaluator’s knowledge, experience, and personal assessment.
  • Score 5 — No noticeable issues: The image contains no identifiable artifacts, abnormal textures, or inappropriate processing. The enhancement and denoising results are highly consistent with the evaluator’s relevant knowledge and experience.

(3) Constructiveness (Usefulness for Biological Assessment) Evaluate whether the image facilitates biological assessment or further research, including but not limited to cell counting, cell segmentation, morphological observation, and quantitative analysis.

  • Score 1 — Not useful at all: The image does not support biological assessment and may even be misleading or make interpretation more difficult.
  • Score 2 — Mostly not useful: The image provides no noticeable improvement compared with direct observation of the original image.
  • Score 3 — Somewhat useful: The image improves the visibility of some structures or details and provides limited assistance for biological observation or analysis.
  • Score 4 — Highly useful: The image clearly presents most structures and details relevant to the assessment and facilitates cell counting, segmentation, morphological observation, or other biological analyses.
  • Score 5 — Extremely useful: The image substantially improves the visibility and interpretability of relevant structures and details, reliably supporting cell counting, segmentation, quantitative analysis, or other further analyses.

Swap experiment: Experts performed cell-counting tasks on different slides, and their counts were compared with the ground-truth values. To prevent prior exposure to the original slides from influencing the evaluation of the AI-processed slides, the experts were divided into two groups: Group A counted cells in the original images, while Group B counted cells in the AI-processed images. The two groups then switched tasks and performed cell counting on another set of previously unseen slides.

Reviewer moa1 · CommentOpenReview ↗

Thanks for your response.

  1. First, the response still does not clearly separate the paper’s novel contribution from orchestration of existing components. The system combines agents, RAG, memory, segmentation, expert models, image-editing models, reward models, rollback, and RL/co-evolution, but it remains difficult to identify which component is scientifically essential.
  2. Second, the segmentation/reward concern is not adequately addressed. The response says a fine-tuned SAM3 model is used and can be replaced through a Pydantic interface, but this does not answer the key issue: if segmentation is wrong on OOD microscopy data, the MicroAuthenticator reward may guide the co-evolution process in the wrong direction.

What's more, how the SAM3 segmented objects are classified to match the user prompt. Only works when the whole image contains one class of object, such as cells. May not work in a complicated bioimage such as HE.

  1. Third, reproducibility remains a major issue. The response says prompts are in the appendix and code will be released upon acceptance, but the full system depends on more than codes such as RAG content, memory templates, and co-evolution details.
  2. Fourth, the added human-evaluation results are potentially useful but not enough in their current form. The design, statistical testing, task details, expert instructions, image sampling protocol, and blinding/randomization are not sufficiently described.

I would like to keep my score now.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…