potentialpaper

What, Where, and Boundary: Hierarchical Cognitive Decomposition for Echocardiography Video Segmentation

Long Zheng, Zhi Li, Weidong Wang, Chenxi Zhu, Zhenyu Dai, Minyi Guo

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. We propose a hierarchical cognitive decomposition framework that maps the stages of clinical expert interpretation to dedicated modules for efficient and accurate echocardiography video segmentation.

Abstract. Segmenting the left ventricle in echocardiographic videos remains difficult because the target undergoes continuous deformation and rapid displacement across the cardiac cycle, while low tissue contrast further obscures its endocardial boundaries. Inspired by the roles of anatomical knowledge and focused inspection in clinical interpretation, we organize segmentation around three functional questions: What is the target? Where is it now? Where does the boundary lie? We propose Hierarchical Cognitive Decomposition (HCD), a cognition-inspired framework that translates these questions into three complementary stages of identity anchoring, spatial localization, and boundary delineation. To capture invariant target identity amid changing appearances, Static Identity Anchoring (SIA) anchors the first annotated frame as a semantic reference, enabling stable recognition across the cardiac cycle. To maintain spatial focus despite inter-frame motion, Adaptive Gaze Prior (AGP) converts the previous frame's prediction into a spatial attention prior that localizes the current target position. To resolve boundary ambiguity under low tissue contrast, Structural Boundary Perception (SBP) extracts multi-scale boundary cues within the localized region. On the CAMUS and EchoNet-Dynamic benchmarks, HCD achieves state-of-the-art performance with only 1.35M trainable parameters (out of 35.2M total) at 68 FPS, demonstrating the effectiveness of this clinically inspired decomposition for accurate and efficient segmentation. The code is available at https://github.com/ZhengLong777/HCD.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
4 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:46 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The reviewers recognize the paper as a well-motivated and technically plausible framework for left-ventricular echocardiography video segmentation. However, the current discussion hinges on whether the evidence sufficiently supports the paper’s main claims. At this stage, the authors should focus the rebuttal on the following points, which are most relevant to the final discussion:

  1. Please address Reviewer 2abz’s concern about the clinical significance of the reported gains.
  2. Please address Reviewer w9sD’s concern about the strength of the evidence for the proposed “What Where Boundary” cognitive decomposition.
  3. Please respond to Reviewer Eyad’s and Reviewer w9sD’s concerns regarding the dependence on the first-frame anchor.
  4. Please address Reviewer 2abz’s and Reviewer w9sD’s concerns about the fairness and interpretability of the empirical comparisons.
Final justification

In the rebuttal, the authors resolved most of the concerns raised by the reviewers. Given its strong empirical validation and clear practical utility, the paper is recommended for acceptance.

Area Chair HF85 · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

The reviewers recognize the paper as a well-motivated and technically plausible framework for left-ventricular echocardiography video segmentation. However, the current discussion hinges on whether the evidence sufficiently supports the paper’s main claims. At this stage, the authors should focus the rebuttal on the following points, which are most relevant to the final discussion:

  1. Please address Reviewer 2abz’s concern about the clinical significance of the reported gains.
  2. Please address Reviewer w9sD’s concern about the strength of the evidence for the proposed “What Where Boundary” cognitive decomposition.
  3. Please respond to Reviewer Eyad’s and Reviewer w9sD’s concerns regarding the dependence on the first-frame anchor.
  4. Please address Reviewer 2abz’s and Reviewer w9sD’s concerns about the fairness and interpretability of the empirical comparisons.
Final justification

In the rebuttal, the authors resolved most of the concerns raised by the reviewers. Given its strong empirical validation and clear practical utility, the paper is recommended for acceptance.

1 comment
Authors · CommentOpenReview ↗

Response to the Area Chair: the four decision-relevant points

We address the four points in order, full protocols and results are in the reviewer-specific replies.

1. Clinical significance of the reported gains. Across three independent controlled runs under GDKVM's protocol, HCD reached 95.27+-0.03 mDice / 2.573+-0.025 mm HD95 versus 95.00+-0.04 / 2.703+-0.015 for GDKVM, ranking better in every run. Table 1's +- values describe frame-level dispersion, whereas these analyses evaluate run-to-run variability and uncertainty in paired patient-level effects. Accounting for correlated 2CH/4CH views, both paired effects favoured HCD (+0.23 mDice points, -0.143 mm HD95; Holm-adjusted p=0.077 for both). Error-tail and downstream measures pointed the same way but were likewise inconclusive; patients with absolute LVEF error above 10 points fell from 9/50 to 3/50. These results support a reproducible technical improvement, while clinical benefit requires larger-cohort validation. The contribution also rests on cost and scope: 1.35M trainable parameters (3.8% of the model) at 68 FPS on one RTX 2080 Ti, and a joint LV-cavity/myocardium/left-atrium model adding 585 trainable parameters that reaches 92.05+-0.09 macro mDice.

2. Evidence for the What-Where-Boundary decomposition. The contribution is the explicit decomposition into target identity, spatial localization, and boundary delineation, not novelty in the lightweight operators instantiating it; it derives from the clinical reading workflow rather than from architecture search, so the controls below evaluate the design rather than define it. Our eight-configuration ablation covers every SIA/AGP/SBP combination: the full model is best on both metrics (95.21 mDice / 2.59 mm HD95), removing any one module worsens both, and the complete configuration improves on the no-module baseline by 1.22 mDice and 0.90 mm. Over three runs the sequential form beat a parallel variant on both metrics (95.27+-0.03 / 2.573+-0.025 mm versus 95.13+-0.02 / 2.727+-0.049 mm), and across all six stage orders the three placing localization before boundary refinement took the top three positions on both metrics. Margins among the leading orders were close, however, and exchanging identity conditioning with localization showed no consistent advantage. SIA and AGP attention maps and an SBP boundary-confidence comparison show each module acting where intended. We therefore claim the decomposition as implemented in HCD and a design preference for localization before boundary refinement, not a uniquely necessary order, and we do not claim that the architecture reproduces expert cognition.

3. Dependence on the first-frame anchor. Degradation under an imperfect first-frame annotation is graded, monotonic in perturbation strength, and error-type dependent rather than all-or-nothing. Without retraining we perturbed only the annotation across five error families (anchor Dice = Dice against the first-frame ground-truth mask). For the submitted checkpoint, performance was 95.21 mDice / 2.59 mm HD95 with a clean anchor; at anchor Dice 0.90-0.92 the largest degradation across the five families was 2.20 mDice and 1.01 mm. Error type mattered more than anchor Dice alone: at 0.840 versus 0.838, systematic dilation cost 6.2 mDice points against 1.8 for irregular contour noise. A 14-pixel translation (anchor Dice 0.70) gave 85.9 mDice. This is consistent with SIA retrieving features softly rather than imposing the annotation as a hard pixel mask. In a further control, over three runs a fixed-crop variant reached 94.99+-0.05 mDice / 2.673+-0.032 mm against HCD's 95.27 / 2.573 mm, so in this implementation a fixed region of interest did not match identity conditioning.

4. Fairness and interpretability of the comparisons. HCD is evaluated strictly under GDKVM's protocol: the same split, preprocessing, test cases, and metric implementation. Table 1's baseline values are therefore taken from GDKVM's published comparison table rather than assembled across papers with differing protocols, with E3SAM2 and EchoVim the only additions; as we did not reproduce those two, they will be labelled Reported from their original papers and used only as supplementary context. We also retrained HCD and GDKVM three times each under this protocol, each keeping its own architecture and optimization settings. Our GDKVM reproduction closely matched its published mDice (95.00+-0.04 versus 95.11) and achieved better HD95 (2.703+-0.015 versus 3.05 mm), so it was not uniformly weaker than the published result. The 68 FPS above and GDKVM's published 37 FPS come from different hardware and timing setups, so cross-hardware differences remain indicative rather than controlled.

Together these controls support a parameter-efficient, clinically motivated framework with reproducible gains and quantified anchor sensitivity.

Reviewer w9sDOpenReview ↗
Rating
4/6
Confidence
5/5
Quality
3/4
Clarity
4/4
Significance
3/4
Originality
2/4
Contribution type
use_inspired
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes a novel echocardiography video segmentation framework termed Hierarchical Cognitive Decomposition (HCD), motivated by the hierarchical cognitive process reportedly followed by expert echocardiographers during image interpretation. This work addresses the central challenge of left ventricular segmentation under substantial shape deformation, rapid motion, and ambiguous boundaries by decomposing the task into three sequential stages: target identity recognition ("What"), spatial localization ("Where"), and boundary delineation ("Boundary"). To implement this decomposition, the authors introduce three dedicated modules: Static Identity Anchoring (SIA), Adaptive Gaze Prior (AGP), and Structural Boundary Perception (SBP). Built upon a frozen SAM2-Hiera backbone with lightweight trainable adapters, the method achieves strong performance on CAMUS and EchoNet-Dynamic while maintaining high inference efficiency and a relatively small number of trainable parameters. The paper argues that explicitly embedding clinical cognitive priors into model architecture leads to more effective and efficient echocardiography video segmentation.

Strengths and weaknesses

Strengths: One notable strength of the paper is the clear conceptual framing of the problem. Rather than proposing another generic temporal segmentation architecture, the authors formulate the task through a clinically inspired cognitive hierarchy and establish a relatively coherent correspondence between the three cognitive stages and the proposed network modules. This perspective is intuitively understandable and improves the interpretability of the overall architecture. The explicit decomposition of identity retrieval, localization, and boundary refinement also provides a more structured narrative than many existing memory-based video segmentation approaches.

Weakness:

  1. The primary weakness lies in the limited methodological novelty beneath the cognitive interpretation. Although the paper presents a compelling cognitive narrative, the actual implementations of SIA, AGP, and SBP largely correspond to existing architectural patterns, including cross-attention-based reference retrieval, previous-mask-guided spatial priors, and multi-scale convolutional boundary enhancement. As a result, it remains unclear whether the performance gains originate from the proposed cognitive decomposition itself or simply from a favorable combination of known design components. The claims of the paper regarding cognitive modeling, therefore, appear stronger than the evidence provided.
  2. The experimental evaluation lacks sufficiently strong evidence supporting the central hypothesis of cognitive decomposition. Although ablation studies demonstrate the contribution of individual modules, there is no direct validation that the proposed three-stage hierarchy corresponds to human cognitive behavior or that the ordering of the stages is fundamentally important. Alternative decompositions, different module orderings, or non-hierarchical variants are not investigated. Consequently, the paper demonstrates that the proposed architecture works, but not necessarily that the cognitive interpretation is the reason why it works.
  3. The comparison protocol raises several concerns regarding fairness and completeness. Many baseline results are directly cited from previous papers rather than reproduced under a unified experimental setting. Since the reported performance improvements are relatively small on some benchmarks, stronger and more controlled comparisons are necessary to convincingly establish state-of-the-art status.
  4. The discussion of generalization remains limited. The proposed method is specifically designed around left ventricular segmentation with a first-frame annotation available. It is unclear whether the approach can extend to multi-structure cardiac segmentation, pathological cases with severe anatomical variation, or more general medical video segmentation tasks. The current experiments provide limited evidence regarding robustness and transferability.
Questions
  1. The paper's central claim is that cognitive decomposition improves segmentation performance. However, no experiments investigate whether alternative decompositions or different module orderings perform similarly. I encourage the authors to compare multiple decomposition strategies and stage permutations to determine whether the proposed "What → Where → Boundary" sequence is genuinely important or merely one effective implementation.
  2. The proposed cognitive interpretation would be considerably stronger if supported by direct evidence from human perception studies. The authors may consider incorporating attention-map comparisons or other quantitative evaluations demonstrating alignment between model behavior and expert diagnostic behavior.
  3. Several baseline methods are reported from prior publications rather than reproduced. Given the relatively small improvements over the strongest competitors, it would be beneficial to reproduce the most recent methods under an identical training protocol and backbone setting to ensure fair comparison.
  4. The reliance on a single first-frame anchor is a key design assumption. Additional experiments should investigate cases where the initial frame is atypical, noisy, or poorly annotated, as such situations may significantly affect clinical deployment. Robustness analyses under imperfect anchor conditions would strengthen the paper.
Limitations

Although the paper discusses several failure cases, the limitation analysis remains relatively narrow. The authors should more explicitly discuss dependence on first-frame annotation quality, applicability to non-periodic motion patterns, robustness under severe pathology, and potential risks when extending the framework to multi-object segmentation.

Final justification

After rebuttal, the authors have addressed most of my major concerns. Importantly, the authors have appropriately narrowed their claims and clarified that HCD is a cognition-inspired decomposition rather than a reproduction of expert cognition. While the methodological novelty remains moderate because the individual operators are largely built upon existing techniques, the explicit decomposition strategy, comprehensive validation, and strong empirical performance make the work a valuable contribution. So I retain my rating.

Formatting concerns

N/A

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for pressing us on both the source of the decomposition and the evidence for it; we answer both in turn.

Where the decomposition came from, and what the controls show. The methodological novelty lies in the lightweight architectural composition of explicit identity, localization and boundary pathways, motivated in Sec. 2.2 and formalized by the sequential transformations in Sec. 3.2, rather than in any individual operator or a claim of reproducing expert cognition. The three modules were inspired by clinical reading practice, which we abstracted as three questions asked in turn, and each module was introduced to answer one of them. Which structure is being read comes first: depending on the indication a clinician reads the left ventricle, the myocardium or the left atrium, and knows the target before looking for it, whereas the network has no such prior, so we state the target explicitly by keeping the annotated first frame as a reference. A reader who knows the target then looks where it should be, and since consecutive frames are continuous we supply the previous frame's prediction as a spatial prior. With target and region settled, the reader inspects local detail there, so we refine those details with boundary-sensitive filtering.

Under a computational-efficiency constraint, we intentionally instantiate these functions with established lightweight operators; the contribution is not the operators themselves but that identity, localization and boundary delineation are modelled explicitly, instead of being extracted implicitly by end-to-end learning from temporal features.

The submitted order was derived from that intended information flow rather than selected by architecture search. To measure how much the composition strategy and the stage order matter, we compared the submitted cascade with a parallel variant and with every stage order on CAMUS, three independent runs each. Across those runs, mDice / HD95 were 95.27+-0.03 / 2.573+-0.025 mm for SIA-AGP-SBP (submitted), 95.24+-0.02 / 2.563+-0.040 for AGP-SIA-SBP, 95.21+-0.01 / 2.583+-0.032 for AGP-SBP-SIA, 95.20+-0.02 / 2.700+-0.030 for SIA-SBP-AGP, 95.16+-0.03 / 2.603+-0.021 for SBP-AGP-SIA, and 95.05+-0.06 / 2.723+-0.050 for SBP-SIA-AGP. The parallel variant, which computes the boundary branch from the unmodulated f3 and merges it afterwards instead of from the identity-conditioned and localized representation, gave 95.13+-0.02 and 2.727+-0.049 mm.

The submitted cascade had the highest mean mDice, but a 0.03-point margin over the next order does not establish a uniquely optimal sequence. The pattern is consistent across both metrics: the three orders in which localization precedes boundary refinement, and only those three, occupy the top three positions on both metrics, and the parallel control, which removes that dependence by composition rather than by ordering, falls with the lower group. With the position of boundary refinement fixed, exchanging identity conditioning and localization changed mean mDice by 0.01 to 0.11 with no consistent winner. That limited sensitivity matches the computation graph: the first-frame identity reference and the previous-frame spatial prior are both available before current-frame refinement and neither is generated by the other, so exchanging them changes the intermediate representation but not the information supplied. These controls therefore indicate a design preference for localization before boundary refinement, while not establishing a uniquely necessary ordering between identity conditioning and localization.

We will add these controls to the revision and state the contribution accordingly: the three pathways follow the clinical reasoning above, whereas the What -> Where -> Boundary arrangement is one effective instantiation, within which boundary refinement after localization is the pattern indicated by the data. We will also state the scope of the cognitive framing explicitly in the abstract and Section 1: the architecture is modelled on the clinical reading workflow, not claimed to reproduce expert cognition.

Whether the three modules perform the functions they were designed for. As set out above, the design makes target, region and detail explicit in the architecture rather than leaving them to be learned implicitly. The design is inspired by that clinical workflow, and we do not claim that it reproduces the cognitive process of an expert reader.

Whether each module performs its intended function is something we can check. We visualized the attention of SIA and AGP on a test sequence and will add the figure to the appendix. Current-frame LV tokens attend to the LV region of the anchor rather than to the background, whereas a background token attends diffusely, so the identity pathway retrieves the target from the anchor rather than reading it indiscriminately; and the AGP prior stays localized on the LV across frames, so the localization pathway carries the current region. For SBP, the boundary-confidence comparison with and without the module shows the confidence gains concentrated at low-confidence boundary regions rather than in the cavity interior, so the boundary pathway acts where it is intended to. We present these as role diagnostics rather than evidence of alignment with expert behaviour.

Fairness and provenance of the comparisons. For a fair comparison we followed the same evaluation protocol as GDKVM: the same CAMUS split, preprocessing, test cases and metric implementation. Every baseline row except E3SAM2 and EchoVim is therefore taken from the values reported in GDKVM's paper; we added E3SAM2 and EchoVim for coverage of more recent work, and we will mark them in the table as not protocol-verified and exclude them from statistical claims.

We did not rest the small margin on the reported values alone. Retraining HCD and GDKVM three times each under GDKVM's protocol, with each method keeping its own architecture and training settings, gave 95.27+-0.03 mDice and 2.573+-0.025 mm HD95 for HCD versus 95.00+-0.04 and 2.703+-0.015 mm for GDKVM, with HCD better in every run. In the final manuscript the comparison table will label each result as Reported or Reproduced with its protocol status, and statistical claims will be restricted to the controlled reproduction.

Robustness under an imperfect first-frame anchor. We ran this experiment for the rebuttal. Without retraining, we perturbed only the first-frame annotation supplied at inference; the ground-truth masks used for evaluation were unchanged. We swept five perturbation families on CAMUS (dilation, erosion, mixed morphology with translation, pure translation, and irregular Gaussian contour noise), and use anchor Dice for the agreement between the perturbed annotation and its ground truth.

From 95.21 mDice / 2.59 mm HD95 with a clean anchor, contour noise gave 95.06 / 2.65 mm at anchor Dice 0.97, 94.93 / 2.73 at 0.95, 94.72 / 2.85 at 0.92, 94.34 / 3.03 at 0.89, 93.94 / 3.23 at 0.87, and 93.45 / 3.46 at 0.84. Within each family the decline was monotone in perturbation strength and progressive rather than abrupt. At anchor Dice 0.90-0.92 the largest degradation across the five families was 2.20 mDice points and 1.01 mm HD95. Sensitivity depended on error type rather than anchor Dice alone: at nearly identical anchor Dice (0.840 versus 0.838), systematic dilation cost 6.2 mDice points whereas irregular contour noise cost 1.8. Accuracy is not retained under gross perturbation: the most severe setting in our sweep, a rigid translation of the whole annotation by 14 pixels, gives anchor Dice 0.70 and 85.9 mDice. Anchor quality therefore matters, but the effect is graded and error-type dependent rather than an all-or-nothing failure of the sequence. Under contour noise the sensitivity is bounded: reducing anchor Dice from 1.00 to 0.84 cost 1.76 mDice points and 0.87 mm HD95.

Generalisation and limitations. We ran the multi-structure extension for this rebuttal, jointly segmenting the LV cavity, myocardium and left atrium over three runs under the same CAMUS split and semi-supervised protocol as the main experiments, with ground truth available only at the first and last frames of each clip, so its LV-cavity result is directly comparable to Table 1. It adds only 585 trainable parameters (about 0.04% of the trainable budget) and reached 92.05+-0.09 mDice and 3.38+-0.04 mm HD95 averaged over the three foreground structures. Joint training reduced LV-specific accuracy relative to the dedicated model (94.18 versus 95.21 mDice), so the extension is feasible at negligible parameter cost while the dedicated model remains preferable for LV-only analysis.

Our evidence covers two echocardiography benchmarks, trained and tested separately, and so supports consistent behaviour on both rather than demonstrated transferability. Three directions remain open: pathology-stratified robustness under severe anatomical variation; irregular rhythms, where AGP derives frame-dependent spatial guidance from the preceding segmentation state and so assumes no periodicity, but arrhythmic sequences were not evaluated; and non-cardiac medical video.

We will expand the Limitations section accordingly, including first-frame annotation quality and the absence of anchor-quality assessment or fallback, the calibrated scope of the cognitive framing and stage order, the absence of pathology-stratified and irregular-rhythm evaluation, and the risks of a multi-object extension.

Reviewer EyadOpenReview ↗
Rating
5/6
Confidence
5/5
Quality
4/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
use_inspired
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes a novel framework, Hierarchical Cognitive Decomposition (HCD), for echocardiography video segmentation. Inspired by the global-to-local cognitive workflow of expert cardiologists, the authors decompose the segmentation task into three distinct stages: target identification (what), spatial localization (where), and boundary delineation (boundary). These three stages are implemented through three lightweight modules (SIA, AGP, and SBP) and integrated into a frozen SAM2 backbone. The method achieves state-of-the-art performance on both the used datasets, demonstrating high accuracy (mDice and clinical LVEF estimation) along with remarkable computational efficiency (achieving 68 FPS with only 1.35M trainable parameters).

Strengths and weaknesses

Strengths:

  1. Originality & Motivation: The architectural design is highly innovative. By mapping the human clinical cognitive process (from global survey to local inspection) directly into specific neural network modules, the authors provide a transparent, biologically-inspired alternative that breaks away from standard end-to-end black-box models. The shift from dynamic memory tracking (which is prone to error accumulation) to Static Identity Anchoring (SIA) offers a refreshing and highly effective perspective for periodic cardiac motion.
  2. Quality & Efficiency: The model design is highly elegant and parameter-efficient. By adopting a frozen SAM2 backbone and fine-tuning only lightweight adapters (accounting for just 3.8% of total parameters), the framework achieves a high throughput of 68 FPS. This resolves a major bottleneck in deploying complex vision foundation models on edge or clinical ultrasound devices.
  3. Significance & Clinical Relevance: Unlike many medical imaging papers that over-focus on geometric metrics (such as Dice), this paper successfully bridges the gap to clinical utility. The comprehensive evaluation of Left Ventricular Ejection Fraction (LVEF) estimation demonstrates an extremely high Pearson correlation (0.914) and tight limits of agreement (Bland-Altman plots), strongly validating its tangible clinical value.
  4. Clarity: The paper is exceptionally well-written. The logical transition from psychological/medical perception theories (Section 2.2) to specific mathematical operators (Section 3) is seamless and highly persuasive. The ablation studies comprehensively and convincingly isolate and validate the contribution of each module.

Weaknesses:

  1. Vulnerability of the Static Anchor: Although Static Identity Anchoring (SIA) successfully prevents identity drift, it fundamentally relies absolutely on the first-frame annotation (G0G_0). If the first frame suffers from severe acoustic shadowing, poor annotation, or extreme foreshortening (as the authors pointed out in the failure cases in Fig. 7), the entire subsequent sequence will be compromised. The paper lacks a fallback mechanism or a quality assessment module for the initial anchor.
  2. Lack of Multi-Modal Physiological Priors: Given that the method relies heavily on temporal continuity and the periodic nature of the cardiac cycle, integrating external physiological signals (such as synchronized ECG data, which is standard in echocardiography) could provide explicit prior knowledge for the "Where" (AGP) module. Although this is not strictly a flaw, it represents a missed excellent opportunity for a cognitive-inspired framework.
  3. Limited Target Scope: The current pipeline and experiments are highly optimized for a single target (the left ventricle). It remains unclear whether this three-stage cognitive decomposition can elegantly scale to simultaneous multi-structure segmentation (e.g., segmenting the left ventricle, left atrium, and myocardium concurrently), which requires "divided attention" in a clinical setting.
Questions

Q1 Sensitivity to Anchor Quality: How sensitive is the HCD framework to the quality of the first-frame annotation (G0G_0)? Have you conducted any experiments to simulate annotation noise or introduce varying degrees of ambiguity to G0G_0 to observe how downstream metrics degrade? I hope to see relevant evidence during the rebuttal phase.

Q2 Dynamic Key-Frame Updating: Given the limitations observed in cases of extreme foreshortening, have you considered a "hybrid" anchor approach? For instance, could you cache a highly confident, dynamically selected key-frame from later in the cardiac cycle to augment (rather than replace) the static anchor?

Q3 Generalization to Multi-Class Segmentation: Can the proposed AGP (Adaptive Gaze Prior) and SBP modules be easily extended to multi-class segmentation without causing a linear increase in trainable parameters or a significant drop in FPS? From a clinical perspective, if this approach could achieve high performance and efficiency across different cardiac structures simultaneously, it would represent a very significant contribution.

Limitations

yes.

The current study focuses exclusively on the segmentation and optimization of a single target (the left ventricle), which inherently limits its broader clinical deployment and utility. Extending this framework to segment diverse cardiac structures would significantly enhance its clinical value. Therefore, I strongly suggest that the authors either provide supplementary results on multi-structure segmentation or, at the very least, expand the "Limitations" section to include a thorough discussion on the challenges and potential strategies for scaling this approach to other structures.

Final justification

After reviewing the rebuttal and the additional experiments, I believe the authors have substantially addressed my main concerns, particularly regarding first-frame anchor robustness and multi-structure extensibility. The remaining limitations are now appropriately characterized and do not undermine the main technical contribution. I therefore increase my rating from 4 to 5.

Formatting concerns

none

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for the constructive questions on anchor robustness and multi-structure extension; we answer each with new experiments below.

Sensitivity to first-frame anchor quality. Within the intended first-frame-supervised setting, degradation is gradual under moderate annotation noise and strongly error-type dependent, with coherent geometric bias the main sensitivity. We ran this experiment for the rebuttal. Without retraining, we perturbed only the first-frame annotation supplied to the model at inference. We swept five perturbation families on CAMUS: dilation, erosion, mixed morphology with translation, pure translation, and irregular Gaussian contour noise, the last of which was designed as a synthetic proxy for local contour ambiguity. We use "anchor Dice" to denote the Dice between the perturbed first-frame annotation and its ground truth, while mDice and HD95 measure downstream video-segmentation performance.

With the unperturbed annotation (anchor Dice=1.00), HCD achieved 95.21 mDice and 2.59 mm HD95. Under contour noise, mDice / HD95 degraded to 95.06 / 2.65 mm at anchor Dice 0.97, 94.93 / 2.73 at 0.95, 94.72 / 2.85 at 0.92, 94.34 / 3.03 at 0.89, 93.94 / 3.23 at 0.87, and 93.45 / 3.46 at 0.84. Within each perturbation family, performance degraded monotonically with perturbation strength, and the decline was progressive rather than abrupt over the tested range.

Two findings are important. First, sensitivity depends on error type rather than anchor Dice alone: at nearly identical anchor Dice values (0.840 versus 0.838), systematic dilation reduced mDice by 6.2 points, whereas irregular contour noise reduced it by 1.8 points. This suggests that coherent geometric bias is more damaging than local contour irregularity. Second, at anchor Dice 0.90-0.92, the largest degradation across all five families was 2.20 mDice points and 1.01 mm HD95.

These results confirm that anchor quality matters, while showing a graded and error-type-dependent effect rather than all-or-nothing sequence failure. At anchor Dice 0.70, produced by a translation of 14 pixels, performance fell to 85.9 mDice, well below the clean-anchor result. Mechanistically, SIA performs soft feature-level retrieval rather than imposing the annotation as a hard pixel constraint, AGP re-estimates frame-dependent localization, and SBP refines the boundary using current-frame evidence. Anchor errors can therefore influence subsequent frames without being copied forward as a hard mask. Consistent with this, under contour noise at anchor Dice 0.84 the model still reached 93.45 mDice and 3.46 mm HD95.

The submitted method assumes a verified first-frame annotation, consistent with the evaluated setting; automatic anchor-quality assessment and fallback are not part of the current system, and we will state this deployment scope explicitly in the Limitations section.

Hybrid auxiliary anchor. We appreciate this suggestion and implemented exactly that: keeping the static identity core and adding one reliable later frame rather than accumulating dynamic memory. We built it as an inference-only extension of the submitted checkpoint, with no retraining and no additional parameters. It caches at most one auxiliary feature map and its consensus pseudo-mask, chosen without any later-frame label: the reliability score is the harmonic mean of agreement under a fixed photometric test-time-augmentation set and boundary certainty, while decoder-head agreement, consistency with the first-frame identity and a predicted-area sanity check act as vetoes rather than scores. The selection threshold and the auxiliary weight were chosen on the validation split and applied unchanged to the test split.

This variant tracked the static path closely. On a clean anchor the two were numerically similar (95.20 versus 95.21 mDice, 2.596 versus 2.592 mm HD95), and across all thirty perturbed settings the change in degradation stayed within 0.03 mDice points, so we observed no measurable change. Its selection behaviour was conservative: an auxiliary frame was admitted for 22% of clips with a clean anchor, and for 0%, 3.7% and 2% under the strongest dilation, mixed-morphology and translation perturbations, while under erosion, which removes rather than adds foreground, admission remained near 16%. When no candidate is admitted, inference reverts exactly to the submitted static path, so the branch can be added to the submitted model at inference time with no measurable change; the gate scores candidate later frames, not the first-frame anchor.

The reviewer-proposed auxiliary anchor therefore produced no measurable improvement across the tested conditions, so we retained the submitted static design; whether a better quantitative criterion can identify later frames that measurably help when the first frame is poor is the direction we will pursue.

Extension to multi-structure segmentation. We ran this extension for the rebuttal, jointly segmenting the LV cavity, myocardium, and left atrium (four classes including background). It uses the same CAMUS split, test patients, data pipeline, and semi-supervised protocol as the main experiments, with ground truth available only at the first and last frames of each clip; its LV-cavity results are therefore directly comparable to Table 1.

Directly answering Q3, only the output heads scale with the number of classes: the three 1x1 decoder heads widen from one to four channels, adding 585 trainable parameters, approximately 0.04% of the trainable budget, so the trainable share remains 3.8% of the total parameters. SIA and AGP are shared rather than replicated across structures: SIA gates the first-frame reference using the union of the annotated structures, while AGP uses the overall foreground probability derived from the softmax output. Both therefore retain the same weights and a single evaluation per frame. SBP is unchanged: it enhances boundary-sensitive features rather than producing a per-class output, so it required no modification. The frozen SAM2 backbone is also unchanged and is evaluated only once per frame.

For throughput, because the RTX 2080 Ti used in the submission was no longer available, we evaluated only the relative overhead of multi-structure prediction on the same RTX A6000 using identical synchronized model-forward timing. The single-structure and four-class models achieved 222.73+-0.75 and 214.63+-0.54 FPS, respectively (mean+-SD over three repeats), corresponding to a 3.6% throughput reduction. These values are used only for the controlled within-A6000 comparison and are not compared with the submission's reported 68 FPS because the hardware and measurement protocols differ.

Across three independent training runs, Dice was 94.18+-0.04 for the LV cavity, 89.44+-0.27 for the myocardium, and 92.54+-0.32 for the left atrium. The corresponding HD95 values were 3.22+-0.03, 3.28+-0.05, and 3.63+-0.07 mm. Averaged across the three foreground structures, the model achieved 92.05+-0.09 mDice and 3.38+-0.04 mm HD95. The myocardium was the most difficult structure, consistent with its thin geometry and two closely spaced interfaces.

We also report the trade-offs transparently. Joint training reduced LV-specific performance relative to the dedicated single-structure model: LV Dice was 94.18 versus 95.21, HD95 was 3.22 versus 2.59 mm, and LVEF correlation was 0.866+-0.014 versus 0.914. This experiment therefore shows that HCD extends to joint three-structure prediction with negligible parameter growth and a modest throughput cost, while the broader target scope trades some LV-specific accuracy; when only LV analysis is required, the dedicated single-structure model remains preferable. The single-target scope noted in the review is therefore not intrinsic to the framework, and we will add these results and trade-offs to the revision.

Multi-modal physiological priors. We agree that synchronized ECG could provide a useful physiological prior for AGP. However, the released CAMUS and EchoNet-Dynamic data used in our experiments do not provide synchronized ECG signals or R-wave timing, so we cannot evaluate this extension here and do not claim an unmeasured benefit. The current AGP uses no auxiliary physiological signals and estimates no cardiac phase or timing; it converts the previous frame's prediction into a spatial prior over the current frame. ECG would therefore add temporal information of a different kind, and we will discuss ECG-guided localization as a future direction.

Reviewer 2abzOpenReview ↗
Rating
2/6
Confidence
3/5
Quality
2/4
Clarity
2/4
Significance
2/4
Originality
2/4
Contribution type
use_inspired
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper develops a vision pipeline inspired by the methodology used by cardiologists to better segment the left ventricle in echocardiograms. The authors explain the approach and compare their results to to baselines on two echo datasets.

Strengths and weaknesses

Strengths- The authors propose a new approach inspired by human experts with an intuitive explanation of why the approach makes sense and show results that score above other baselines.

Weaknesses- The results seem to be very similar to prior work and there is no good explanation of why this would make a clinical difference. mDice and HD95 seem to be incrementally better than the state of the art GDKVM, and all of these models seem to be within a few percent or mm. The mDice mean is 0.1 points and 0.7 on EchoD but this seems to be within the standard deviation. This raises the bigger question to me of why is this improvement clinically meaningful? Does a cardiologist find a 1 mm or less improvement in segmentation performance useful? Maybe this could be useful in identifying something on the outer wall of the heart but this model doesn’t automatically do that, a clinician would still be looking at that. In terms of clinical outcomes, a quick search shows that AHA guidelines say that EF, which is used to diagnose things like heart failure has a few ranges like 50-75 (normal), 41-49 (reduced/borderline), <40 (reduced, will see symptoms). A 1% difference doesn’t matter here and prior work EchoVIM already shows a small standard deviation. Similarly the mDice score on Fig 5 is marginally higher than prior work DSA (and maybe ~5 fps better?), but there also is no explanation on why this is clinically significant.

Comments

  • Increase the font size on Fig 3 axes and Fig 4 labels
  • What is the watermark on the Fig 3? Is this an AI generated image? This looks like the whole image was generated by AI, not the plotting code. Please explain this and show the underlying data.
  • Static semantic anchor- If the first frame is cached, then don’t errors in annotating this first frame progress to all downstream steps?
  • I don’t understand why the static reference is so critical. If the actual left ventricle is relatively static during the video but deforms then could you just crop the frame to this region

Table 3- What do the rows in this table mean?

Fig 6 image label font size is very small and unreadable

Questions

Why are these results clinically significant (see more in weaknesses above)? If these results are not clinically significant does this paper move the needle in methodology in other ways? For example does it do better on generalizing to edge cases or other datasets that prior models would fail on? What is the AI watermark on Figure 3?

Limitations

The limitations and discussion are combined making the actual limitations very short. It would help to expand these.

Formatting concerns

No

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We thank the reviewer for separating statistical reliability from clinical relevance, and address them in that order.

Reliability of the reported gains. The reported gains are small but stable across independent runs; the "within the standard deviation" concern arises because the +- values in Table 1 reflect variability across test frames, not variability across independent training runs or uncertainty in a paired method difference. We followed the same evaluation protocol as GDKVM, the same data split, preprocessing, test cases and metric implementation, with each method keeping its own architecture and training settings, and retrained HCD and GDKVM three times each. HCD consistently achieved 95.27+-0.03 mDice and 2.573+-0.025 mm HD95, versus 95.00+-0.04 and 2.703+-0.015 mm for GDKVM (mean+-SD across the three new runs; the 95.21 in Table 1 is the submitted checkpoint); HCD ranked better in every run, and the observed mDice ranges did not overlap (95.23-95.29 versus 94.96-95.03). Our reproduction of GDKVM was not uniformly below its published values (HD95 2.70 versus 3.05 mm).

Because the 2CH and 4CH views from one patient are correlated, we used the patient as the primary statistical unit. Across 50 patients, HCD improved mDice by 0.23 points (unadjusted 95% CI: +0.01 to +0.45) and reduced HD95 by 0.143 mm (unadjusted 95% CI: 0.002 to 0.285). Both patient-level estimates favoured HCD, although the evidence became suggestive after Holm correction over the two reported segmentation metrics (adjusted p=0.077 for both); a video-level sensitivity analysis showed the same direction (adjusted p=0.044). The patient-level SD of the paired mDice difference was 0.78 points, which directly characterizes matched method-to-method variability, whereas the 2.18 points in Table 1 is a marginal frame-level spread. We therefore describe the gains as small but reproducible across independent runs, and retain the submitted result (95.21 mDice) unchanged.

The mean geometric gain is not clinically decisive by itself; the matched test set instead shows a directionally favourable, although statistically inconclusive, large-error signal. On whether "1 mm or less" matters, HD95 exceeded 3 mm in 16/100 HCD videos versus 22/100 for GDKVM, the 95th percentile was 3.92 versus 4.40 mm, and the worst decile averaged 4.09 versus 4.69 mm. Because LV contours are used to estimate EDV, ESV and LVEF, these fewer large local deviations carry into the downstream measurement examined next.

Regarding the "1% difference" concern, we agree that a roughly one-point average LVEF difference does not by itself move a patient between the AHA categories the reviewer cites. In our controlled GDKVM comparison, HCD lowered LVEF MAE (4.33 versus 5.32 points) and reduced the number of patients with absolute EF errors above 10 points from 9/50 to 3/50; we used the 10-point threshold because an error of this magnitude is in principle large enough to cross those category boundaries. Paired inference was inconclusive on this test set: exact McNemar gave p=0.18 for the HD95 threshold counts and p=0.11 for the EF counts, and the paired MAE difference had a 95% CI of -0.43 to 2.41 points (Wilcoxon p=0.20). We therefore report these as descriptive effect sizes rather than established clinical benefit, which would require a larger cohort. We report LVEF to test whether improved segmentation supports this downstream task rather than treating Dice and HD95 as isolated endpoints. Relative to EchoVim, HCD shows comparable EF variability and correlation (SD 4.93 versus 4.87; r 0.914 versus 0.908) rather than overall EF superiority, EchoVim having the lower mean bias (0.42 versus 4.19).

Computational efficiency and multi-structure extensibility. If the segmentation gains are read as small, the efficiency of the design is the second half of the contribution: HCD matches or exceeds GDKVM's accuracy while running at 68 FPS on a single RTX 2080 Ti with only 1.35M trainable parameters (3.8% of 35.2M), so the supported claim is real-time inference on commodity hardware rather than a marginal Dice gain. The framework is also not locked to a single structure. A multi-structure variant that jointly segments the LV cavity, myocardium and left atrium, trained on the same CAMUS split and semi-supervised protocol, adds only 585 trainable parameters (about 0.04% of the trainable budget, leaving the trainable share unchanged) because the identity and localization pathways are shared rather than replicated, and segments all three at 92.05+-0.09 mDice averaged over the structures. Per structure, Dice was 94.18+-0.04 for the LV cavity, 89.44+-0.27 for the myocardium and 92.54+-0.32 for the left atrium, over three independent runs with ground truth available only at the first and last frames of each clip, so the LV-cavity value is directly comparable to Table 1. The myocardium was the hardest of the three, consistent with its thin geometry and two closely spaced interfaces. The myocardial wall raised in the review is therefore segmented directly, while joint training costs about one mDice point on the LV cavity relative to the dedicated model (95.21), so the dedicated model remains preferable for LV-only analysis.

On generalisation to other datasets, HCD improves in the same direction on both CAMUS and EchoNet-Dynamic under the published protocols, and the first-frame perturbation sweep below shows graded rather than brittle degradation; on predefined edge-case subgroups we do not claim demonstrated superiority, though the upper-tail analysis above indicates fewer large-error cases. The remaining failure examples identify limitations under near-complete acoustic shadowing on CAMUS and extreme foreshortening on EchoNet-Dynamic.

Regarding DSA in Fig. 5, the approximately 5 FPS gap is not a controlled hardware comparison, whereas the accuracy margin over DSA is considerably larger than the margin over GDKVM: HCD versus DSA achieves 95.21 versus 94.25 mDice and 2.59 versus 3.27 mm HD95 on CAMUS, and 94.38 versus 92.91 mDice on EchoNet-Dynamic. The published DSA throughput and our 68 FPS were measured on different hardware (RTX 3090 and RTX 2080 Ti), and Fig. 5 marks this comparison as indicative, so the directly supported result is 68 FPS on an RTX 2080 Ti.

First-frame anchor: robustness and necessity. Errors in the first-frame annotation can propagate to subsequent frames, and we quantified this dependence. Without retraining, we perturbed only the anchor supplied at inference, testing five perturbation families (dilation, erosion, mixed morphology with translation, translation, and Gaussian contour noise) with anchor-to-GT Dice as the quality axis. On CAMUS, mDice / HD95 changed from 95.21 / 2.59 mm with a clean anchor to 94.5-95.0 / 2.67-2.95 mm at anchor Dice 0.95-0.97, and to 93.0-94.7 / 2.85-3.60 mm at anchor Dice 0.90-0.92. Degradation was monotone in perturbation strength and progressive rather than abrupt, and depended on error type: at nearly identical anchor Dice (0.840 versus 0.838), systematic dilation cost 6.2 mDice points versus 1.8 for irregular contour noise. HCD therefore has some tolerance to imperfect anchors rather than an all-or-nothing dependence, but does not retain clean-anchor accuracy under substantial perturbation: at anchor Dice 0.70, produced by a 14-pixel translation, mDice fell to 85.9.

A fixed crop does not substitute for identity conditioning. To test whether one could "just crop the frame to this region," we replaced SIA with exactly that and changed nothing else. From the same first-frame annotation that SIA uses, we derived a fixed square ROI (0.25 margin, minimum side 32 px), reused it throughout the clip, and mapped predictions back to the original coordinates before evaluation; AGP, SBP, the backbone, split, supervision and schedule were untouched. Over three independent runs this variant reached 94.99+-0.05 mDice and 2.673+-0.032 mm HD95, against 95.27+-0.03 and 2.573+-0.025 mm for HCD, with non-overlapping three-run mDice ranges (94.96-95.05 versus 95.23-95.29) and HCD better on HD95 in every run. A fixed ROI therefore does not substitute for identity conditioning: cropping states where to look, whereas SIA conditions the model on a patient-specific identity reference taken from the annotated first frame, with frame-dependent localization handled by AGP.

Figure 3 provenance and underlying data. No experimental measurement, per-patient value, or reported statistic was generated or altered by generative AI. Fig. 3 was produced from the original per-patient LVEF results using our plotting code. After the figure was downscaled to meet the page limit, some scatter points were no longer clearly visible, so we applied an AI-based super-resolution tool to the rendered image; it inadvertently introduced a watermark that we failed to notice. This was our figure-preparation error, and we apologize. The enhancement affected only the rendered figure and did not alter the underlying per-patient values, analysis, or reported results. Direct recomputation from all 50 per-patient pairs reproduces the annotations printed on the figure after accounting for units (mean difference 0.0419, i.e. 4.19 EF points; regression y=0.81x+12.50; r=0.914). We will replace Fig. 3 in the revision with a watermark-free vector version generated directly from the original values, and can provide the per-patient values on request.

Clarifications and revisions. Table 3 contains all eight SIA/AGP/SBP combinations trained under the same protocol (check/cross = included/removed); row 1 is the baseline and row 8 the full HCD. We will label all rows, enlarge text in Figs. 3, 4 and 6, and expand a separate Limitations section, including first-frame dependence and the two-dataset evidence scope.

Authors · CommentOpenReview ↗

Figure 3: the underlying per-patient LVEF values

As requested, below are all 50 per-patient LVEF values underlying Fig. 3 and the Table 2 entry for HCD. Identifiers are the public CAMUS test-split patient IDs; ground-truth LVEF is computed from the released CAMUS annotations with the same Simpson's-rule implementation as in the paper. These predictions come from the submitted single-structure checkpoint.

patient0027 40.64 39.49    patient0227 60.70 51.61
patient0047 41.13 37.45    patient0228 45.14 38.88
patient0051 33.93 28.33    patient0231 50.86 44.63
patient0052 18.75  5.56    patient0234 48.90 43.88
patient0187 40.02 38.47    patient0237 57.64 55.88
patient0189 75.40 69.33    patient0238 43.15 35.39
patient0191 28.06 26.48    patient0239 55.75 53.01
patient0194 60.59 63.05    patient0240 39.07 32.05
patient0197 59.64 57.81    patient0241 48.39 30.11
patient0199 57.96 59.36    patient0242 46.08 49.76
patient0201 41.36 42.12    patient0243 58.90 55.22
patient0208 51.29 45.45    patient0246 51.04 48.03
patient0213 46.55 38.48    patient0248 49.50 50.11
patient0214 42.06 44.16    patient0251 66.28 56.15
patient0215 58.87 52.41    patient0252 54.44 43.52
patient0217 43.78 49.95    patient0254 48.70 45.04
patient0218 29.75 19.40    patient0258 48.28 46.53
patient0219 60.06 52.29    patient0260 51.07 51.56
patient0220 51.43 48.12    patient0261 48.85 45.61
patient0221 53.57 51.94    patient0262 48.90 41.36
patient0223 56.78 56.72    patient0263 59.96 65.92
patient0224 37.09 37.35    patient0266 36.08 25.83
patient0225 59.34 46.25    patient0269 51.87 48.85
patient0226 63.18 60.07    patient0273 33.57 26.86
                           patient0275 56.49 46.72
                           patient0276 31.12 30.00

(each triplet: patient ID, predicted LVEF, ground-truth LVEF; LVEF values are in percentage points)

For d = predicted minus ground-truth LVEF, direct recomputation gives mean(d) = 4.1882 percentage points, SD(d) = 4.93 under the denominator-n convention of Table 2, Pearson r = 0.914, and the least-squares fit predicted = 0.81 x ground truth + 12.50. With the n-1 denominator, SD(d) is 4.98. Figure 3 reports the mean difference as 0.0419 in fractional LVEF units; Table 2 currently truncates 4.1882 to 4.18, and we will correct it to 4.19.

These predictions come from the submitted checkpoint underlying Fig. 3 and Table 2. The three-run segmentation summaries in our main reply come from independent retrainings performed for the rebuttal, which we ran to establish whether the gain is stable rather than relying on published values. Separately, the paired downstream analysis used a protocol-matched retrained HCD/GDKVM pair (HCD: 95.24 mDice / 2.557 mm HD95; GDKVM: 95.01 / 2.700 mm). That pair yielded LVEF MAE values of 4.33 versus 5.32 and 3/50 versus 9/50 patients with absolute LVEF error above 10 points. These values are not computed from the submitted-checkpoint list above, which yields an MAE of 5.14 and 7/50 such patients.

We apologize for the watermark. Fig. 3 was first generated from the values above using our plotting code. We then applied an AI-based super-resolution tool only to the rendered raster image; it inadvertently introduced the watermark, which we failed to notice. The enhanced image was not used to derive or alter any prediction, measurement, or statistic. We will replace it with a watermark-free vector plot generated directly from these values.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…