potentialpaper

Multi-Bridge Denoising Diffusion Probabilistic Models

Mélodie Monod, Habib Ganjgahi

NeurIPS 2026

Edit this page

Or clone it with git

Run in a terminal:

Needs Git LFS. To push, use an API key from your profile as the password.

Or let your agent set it up

It checks and sets up everything: signing in, git, the clone, credentials and an SSH key.

TL;DR. We introduce MB-DDPM, a many-to-one diffusion bridge framework that combines complementary information from multiple source images to generate a single target image, achieving strong results in medical image translation and image restoration.

Abstract. Image-to-image translation aims to generate a target image conditioned on an observed source image. While diffusion bridge models perform well in one-to-one settings, they are not adapted to problems where multiple sources provide complementary information about a single target. We introduce Multi-Bridge Denoising Diffusion Probabilistic Models (MB-DDPMs), a framework for many-to-one translation that builds stochastic bridges between the target and each source, coupled with a unified reverse process that aggregates information across sources. We evaluate MB-DDPM on brain MRI for multiple sclerosis to predict FLAIR contrast from T1, T2 and PD contrasts. We demonstrate strong clinical relevance through near-perfect agreement with ground-truth lesion-based measurements, highlighting its potential for reliable downstream medical analysis. We further evaluate MB-DDPM on image restoration using CIFAR-10 and ImageNet. Across all datasets, MB-DDPM achieves the highest perceptual quality while maintaining reconstruction fidelity that is competitive with, or superior to, that of the strongest baselines.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
4 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:49 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

The paper introduces Multi-Bridge Denoising Diffusion Probabilistic Models (MB-DDPM), a framework designed for many-to-one image-to-image translation. By constructing independent stochastic bridges between multiple source observations and a single target image—coupled via a shared reverse process—the method aims to aggregate complementary source information effectively. The authors derive a variational training bound and introduce a Hybrid Estimator to balance statistical efficiency and numerical stability. MB-DDPM is evaluated on multi-contrast MRI translation (predicting FLAIR from T1, T2, and PD) and general image restoration (CIFAR-10 and ImageNet), demonstrating strong perceptual/reconstruction performance and clinical relevance via downstream lesion-volume analysis.

Main Strengths

  • Principled Formulation: Solid theoretical foundation extending diffusion bridges from one-to-one to many-to-one settings, supported by a variational bound and a Hybrid Estimator to address SNR degeneracy.
  • Empirical Validation: Strong quantitative performance across natural images and clinical MRI, backed by downstream lesion-volume agreement for MS brain MRI.

Main Weaknesses & Focus Points for the Rebuttal

The reviewers find the paper technically solid, but authors are encouraged to focus their rebuttal on the following points:

  1. Input Scope & Conflicting Sources: Address concerns from Reviewer KN5R and Reviewer L3Qo regarding how the model handles non-complementary, redundant, corrupted, or conflicting sources, as well as Reviewer Zi6R's note on the source conditional independence assumption (Eq. 9) when real-world scans share correlated artifacts or motion.
  2. Baseline Justifications & Comparison Scope: Address Reviewer KN5R's request to justify the baseline choices or compare against modern conditional generation/adaptation baselines, and Reviewer L3Qo's suggestion to compare against existing multi-source/multi-modal diffusion frameworks.
  3. Missing Modalities & Hyperparameter Sensitivity: Address questions from Reviewer L3Qo and Reviewer KN5R regarding performance when a source modality is missing during inference. Additionally, clarify the selection protocol and sensitivity of snr_threshold across different datasets as raised by Reviewer KN5R and Reviewer Zi6R.
  4. Validation Details & Presentation: Address Reviewer KN5R's request to clarify downstream evaluation independence to rule out data/model leakage risks, Reviewer Zi6R's request to clarify disagreement metric normalizations, and fix minor typos/phrasing issues noted by Reviewer Zi6R.

Update post rebuttal

After taking into account the discussion between author and reviewers, I'd like to maintain the acceptance suggestion.

However, I would like to flag two improper citations that should be fixed in the final version of the paper:

@inproceedings{liu2023schrodinger,
  author = {Xingchao Liu and others},
  title = {Schrödinger bridge diffusion models},
  booktitle = {International Conference on Learning Representations},
  year = {2023}
}

The paper title is not accurate and does not match the author list.

@inproceedings{song2021solving,
  author = {Yang Song and Stefano Ermon},
  title = {Solving inverse problems with score-based generative models},
  booktitle = {Advances in Neural Information Processing Systems},
  year = {2021}
}

The actual paper is titled 'Solving Inverse Problems in Medical Imaging with Score-Based Generative Models' (by Yang Song, Liyue Shen, Lei Xing, and Stefano Ermon), which was published at ICLR 2022, not NeurIPS (Advances in Neural Information Processing Systems) 2021. Furthermore, co-first author Liyue Shen and co-author Lei Xing were omitted.

Final justification

Please see meta-review above.

Area Chair TP5H · Meta-reviewOpenReview ↗
Final justification
Please see meta-review above.
Read meta-review
Meta-review

The paper introduces Multi-Bridge Denoising Diffusion Probabilistic Models (MB-DDPM), a framework designed for many-to-one image-to-image translation. By constructing independent stochastic bridges between multiple source observations and a single target image—coupled via a shared reverse process—the method aims to aggregate complementary source information effectively. The authors derive a variational training bound and introduce a Hybrid Estimator to balance statistical efficiency and numerical stability. MB-DDPM is evaluated on multi-contrast MRI translation (predicting FLAIR from T1, T2, and PD) and general image restoration (CIFAR-10 and ImageNet), demonstrating strong perceptual/reconstruction performance and clinical relevance via downstream lesion-volume analysis.

Main Strengths

  • Principled Formulation: Solid theoretical foundation extending diffusion bridges from one-to-one to many-to-one settings, supported by a variational bound and a Hybrid Estimator to address SNR degeneracy.
  • Empirical Validation: Strong quantitative performance across natural images and clinical MRI, backed by downstream lesion-volume agreement for MS brain MRI.

Main Weaknesses & Focus Points for the Rebuttal

The reviewers find the paper technically solid, but authors are encouraged to focus their rebuttal on the following points:

  1. Input Scope & Conflicting Sources: Address concerns from Reviewer KN5R and Reviewer L3Qo regarding how the model handles non-complementary, redundant, corrupted, or conflicting sources, as well as Reviewer Zi6R's note on the source conditional independence assumption (Eq. 9) when real-world scans share correlated artifacts or motion.
  2. Baseline Justifications & Comparison Scope: Address Reviewer KN5R's request to justify the baseline choices or compare against modern conditional generation/adaptation baselines, and Reviewer L3Qo's suggestion to compare against existing multi-source/multi-modal diffusion frameworks.
  3. Missing Modalities & Hyperparameter Sensitivity: Address questions from Reviewer L3Qo and Reviewer KN5R regarding performance when a source modality is missing during inference. Additionally, clarify the selection protocol and sensitivity of snr_threshold across different datasets as raised by Reviewer KN5R and Reviewer Zi6R.
  4. Validation Details & Presentation: Address Reviewer KN5R's request to clarify downstream evaluation independence to rule out data/model leakage risks, Reviewer Zi6R's request to clarify disagreement metric normalizations, and fix minor typos/phrasing issues noted by Reviewer Zi6R.

Update post rebuttal

After taking into account the discussion between author and reviewers, I'd like to maintain the acceptance suggestion.

However, I would like to flag two improper citations that should be fixed in the final version of the paper:

@inproceedings{liu2023schrodinger,
  author = {Xingchao Liu and others},
  title = {Schrödinger bridge diffusion models},
  booktitle = {International Conference on Learning Representations},
  year = {2023}
}

The paper title is not accurate and does not match the author list.

@inproceedings{song2021solving,
  author = {Yang Song and Stefano Ermon},
  title = {Solving inverse problems with score-based generative models},
  booktitle = {Advances in Neural Information Processing Systems},
  year = {2021}
}

The actual paper is titled 'Solving Inverse Problems in Medical Imaging with Score-Based Generative Models' (by Yang Song, Liyue Shen, Lei Xing, and Stefano Ermon), which was published at ICLR 2022, not NeurIPS (Advances in Neural Information Processing Systems) 2021. Furthermore, co-first author Liyue Shen and co-author Lei Xing were omitted.

Reviewer Zi6ROpenReview ↗
Rating
5/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes MB-DDPM, a multi-source diffusion bridge framework for many-to-one image translation. Instead of learning a bridge from one source image to one target image, the method constructs stochastic bridges between the target and multiple source observations, and couples them through a unified reverse process to aggregate information across sources. The paper evaluates the method on multi-contrast brain MRI for predicting FLAIR from T1, T2, and PD, and also on CIFAR-10/ImageNet restoration from multiple degraded observations. Results show strong quantitative performance over diffusion and bridge-based baselines, including downstream lesion-volume agreement for the MRI task

Strengths and weaknesses

Strengths

1: Extending diffusion bridge models from one-to-one translation to many-to-one translation is reasonable and meaningful. This setting naturally fits multi-contrast MRI and multi-observation restoration. 2: The method is formulated in a relatively principled way, with multi-bridge forward and reverse processes and a variational objective, rather than only using heuristic late fusion of multiple sources. 3: The experiments are fairly comprehensive. The paper evaluates both medical image translation and natural-image restoration, reports multiple metrics including PSNR, SSIM, FID, and LPIPS, and includes downstream lesion-volume analysis for the MRI task.

Weaknesses

1: The hybrid estimator uses a tunable snr_threshold, but the selection protocol is not fully clear. It seems to be chosen based on CIFAR-10 experiments. The paper should clarify whether the same value is used for ImageNet and MRI, and how sensitive the results are to this choice.

2: The source-disagreement analysis is interesting, but the disagreement metric and its normalization could be explained more clearly, especially when comparing natural-image degradations and MRI modalities.

3: The core conditional-independence assumption among sources given the target (Eq. 9) may not strictly hold in real-world applications such as multi-contrast MRI, where different scans can share correlated artifacts, for example from patient motion or acquisition protocol effects. It would be useful for the authors to discuss how violations of this assumption might affect the performance and robustness of MB-DDPM in practical scenarios.

4: There are several presentation issues and typos that should be corrected, such as smany, multi-brige, brige, FPD vs. FDP, as the number of sources increases, and incomplete phrasing such as which multiple sources

Questions

Questions

1: How robust is MB-DDPM when one or more source modalities are missing or severely corrupted at inference time?

2: Can the authors comment on how memory and inference cost scale with the number of sources and image resolution, especially when moving toward higher-resolution or 3D medical imaging?

Limitations

Yes.

Final justification

This paper presents a solid and well-motivated extension of diffusion bridge models to many-to-one image translation. The method is technically principled, with a clear multi-bridge forward/reverse formulation, and the experiments show strong results across both multi-contrast MRI synthesis and natural-image restoration. The rebuttal further strengthens the paper by adding sensitivity analysis for the hybrid estimator, clarifying the source-disagreement metric, and evaluating robustness to corrupted sources. Remaining limitations include the lack of explicit source-reliability modeling and the computational challenge of extending the current 2D implementation to high-resolution 3D medical imaging. Overall, I consider this a strong and useful contribution and maintain my recommendation.

Formatting concerns

No major formatting concerns.

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

1. W1 We thank the reviewer for raising this important point regarding the choice and sensitivity of the hyperparameter snr_threshold. In Appendix C.4, snr_threshold=6 was selected based on CIFAR-10 as a compromise between distortion-based metrics (MSE, PSNR, and SSIM) and perceptual metrics (FID and LPIPS). The same value was then used for the ImageNet and MRI experiments. We have added a sensitivity analysis to evaluate the robustness of this choice across datasets.

The results show that MB-DDPM performance is relatively insensitive to the exact value of snr_threshold over the evaluated range [0.5-12]. On CIFAR-10, varying snr_threshold from 12 to 0.5 produces only marginal changes across all metrics. For example, MSE varies between 0.000695 and 0.000697, while PSNR and SSIM remain nearly unchanged. Lower values of snr_threshold slightly improve perceptual metrics, whereas intermediate values provide a better balance with distortion-based metrics. This justified that snr_threshold=6 is a stable operating point.

We observe the same overall behavior on ImageNet and MRI (test set of MRI was restricted to randomly selected subset of 1,000 samples due to time). On ImageNet, varying snr_threshold results in MSE values ranging from 0.00312 to 0.00327 and LPIPS values ranging from 0.1797 to 0.1894. On MRI, MSE varies between 0.00735 and 0.00765, while LPIPS varies between 0.0649 and 0.0678. While lower values of snr_threshold tend to improve perceptual metrics, small values (0.5) can slightly degrade distortion-based metrics. Overall, the variation remains limited and does not affect the conclusions of the experiments.

These results indicate that snr_threshold values in the range of approximately 2-6 provide a consistent trade-off between perceptual and distortion-based metrics, with lower values within this range favoring perceptual quality and higher values favoring reconstruction fidelity.

Crucially, the performance superiority of MB-DDPM over the baselines reported in Table 1 are maintained across all tested values.

Dataset snr_thereshold MSE PSNR SSIM FID LPIPS
CIFAR-10 0.5 0.000697 31.414 0.9625 5.755 0.0437
2.0 0.000696 31.417 0.9626 5.764 0.0437
4.0 0.000695 31.418 0.9626 5.778 0.0437
6.0 0.000695 31.417 0.9626 5.794 0.0438
8.5 0.000695 31.416 0.9626 5.809 0.0438
12.0 0.000696 31.413 0.9626 5.828 0.0439
ImageNet 0.5 0.003174 26.444 0.7727 6.607 0.1797
2.0 0.003125 26.542 0.7690 5.447 0.1820
4.0 0.003202 26.487 0.7709 6.934 0.1823
6.0 0.003190 26.487 0.7655 5.602 0.1856
8.5 0.003272 26.408 0.7669 7.208 0.1860
12.0 0.003269 26.395 0.7611 5.860 0.1894
MRI (1k) 0.5 0.007470 27.482 0.8704 16.415 0.0649
2.0 0.007359 27.568 0.8708 16.415 0.0650
4.0 0.007388 27.561 0.8701 15.901 0.0656
6.0 0.007459 27.511 0.8692 16.041 0.0662
8.5 0.007536 27.477 0.8681 16.269 0.0669
12.0 0.007648 27.398 0.8667 15.977 0.0678

2. W2 The normalization factor 2/(K(K−1))2/(K(K-1)) corresponds to the inverse of the number of unique source pairs, (K2)\binom{K}{2}, and therefore makes DD the mean pairwise disagreement among the sources. Since the scale of E\mathcal{E} depends on the dataset and metric, disagreement values are interpreted within each dataset and metric and are not intended to be directly compared across natural-image degradations and MRI modalities. We clarified this after the definition of the disagreement metric.

3. W3 Concerning the conditional independence assumption, see answer 1. to reviewer L3Qo.

4. W4 We thank the reviewer for pointing us those typos. We have carefully proofread the manuscript and corrected the identified issues.

5. Q1 We thank the reviewer for suggesting an analysis of robustness to corrupted source modalities at inference. In Section 4.1, we evaluate MB-DDPM trained with four source degradations: Gaussian noise, Gaussian blur, JPEG compression (quality factor 5), and 4×4\times bicubic super-resolution (SR4x) on CIFAR-10. Based on our Shapley-value analysis (Appendix E.1.3), these sources have different contributions to reconstruction: Gaussian blur is highly informative, SR4x provides moderate information, while JPEG compression provides relatively limited additional information.

To evaluate robustness, we perturb individual source modalities at inference time. Specifically, we consider three types of perturbations: (i) adding Gaussian noise with σ∈{0.01,0.05,0.1}\sigma\in\{0.01,0.05,0.1\}; (ii) introducing source inconsistency by randomly swapping source pairings; and (iii) reducing the information content of a source by increasing the degradation severity (e.g., stronger blur, lower JPEG quality, or replacing SR4x with SR8x).

The results reveal a clear relationship between source importance and sensitivity to perturbations. Perturbing the weakly informative source has a negligible impact on reconstruction quality, with less than a 1.3% increase in MSE and less than a 1.4% increase in LPIPS even under strong corruption.

In contrast, perturbing highly informative sources leads to substantial degradation. For the Gaussian blur source, even weak Gaussian noise perturbation (σ=0.01\sigma=0.01) significantly affects performance, increasing MSE and LPIPS by approximately 8×8\times and 7×7\times, respectively. Introducing conflicting blur produces a comparable degradation between weak and strong Gaussian noise perturbations. Removing information with a stronger blur leads to a degradation of similar magnitude to that observed with weak Gaussian noise perturbation.

Perturbing the moderately informative source produces an intermediate effect. Weak gaussian noise (σ=0.01\sigma=0.01) has a limited impact, with MSE and LPIPS increases of 4.92% and 5.60%, respectively. However, stronger Gaussian noise (σ=0.1\sigma=0.1) substantially reduces reconstruction quality, leading to approximately 6×6\times increases in both MSE and LPIPS. Further degradation of the SR source, either by using a less granular resolution or introducing conflicting information, also reduces reconstruction quality.

This indicates that at inference MB-DDPM relies less on sources that provide limited additional information about the target image. MB-DDPM can tolerate degradation of sources that provide limited information, but its performance naturally depends on the availability of reliable informative sources. This behaviour is expected for conditional reconstruction models, since sources that contain essential information about the target cannot be arbitrarily corrupted without removing information required for accurate recovery. We will add this analysis to Section 4 and clarify this limitation in Section 5.

We note that the current formulation does not explicitly include a source reliability estimation or adaptive source rejection mechanism and assumes that source will not be corrupted at inference time. A possible future direction is to introduce source reliability modelling or corruption-aware training strategies, where the model is exposed to corrupted sources during training to improve robustness to such inference failures.

6. Q1 Concerning missing sources, see answer 2. to reviewer L3Qo.

7. Q2 Regarding the number of sources KK, we discuss this in Appendix E.5 and report runtime scaling in Tables A7-A9. MB-DDPM applies a U-Net to the concatenated inputs (xt,xT1:K)(\mathbf{x}_t, \mathbf{x}^{1:K}_T) for the conditional estimator. Increasing KK only increases the input channel dimension while keeping the U-Net architecture unchanged. Consequently, the number of parameters increases negligibly, from 988.45988.45M for one source to 988.51988.51M for four sources, with limited runtime overhead due to efficient vectorization during sampling.

In contrast, increasing image resolution has a larger impact on computational and memory requirements, as the number of feature activations and spatial operations grows with image size. Therefore, while increasing KK has a relatively small effect on model size in our implementation, increasing the image resolution can have a substantially larger impact on both memory usage and inference time. This is reflected in the runtime differences between CIFAR-10 (32×3232\times32) and ImageNet (128×128128\times128) reported in Tables A7-A9.

The current implementation uses a 2D U-Net, but the framework can in principle be extended to 3D by replacing 2D operations with their 3D counterparts. However, this would substantially increase memory and computational requirements due to the additional spatial dimension and would likely require strategies such as patch-based processing or reduced feature-map sizes for high-resolution volumetric medical imaging.

We have added this discussion to clarify that the favorable scaling with respect to the number of sources does not directly extend to image resolution or dimensionality.

Reviewer L3QoOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
4/4
Clarity
4/4
Significance
4/4
Originality
4/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper proposes MB-DDPM, a novel multi-bridge diffusion probabilistic model designed to handle "many-to-one" image-to-image translation tasks. Unlike standard diffusion models that collapse multiple observations into a single inference pathway, MB-DDPM constructs independent stochastic bridges from a target image to multiple source images and couples them via a joint reverse process. The authors provide a theoretical framework for the reverse process, introducing a "Hybrid Estimator" that balances the statistical efficiency of conditional estimation with the numerical stability of marginal estimation. The method is validated on standard benchmarks (CIFAR-10, ImageNet) and a clinical MRI dataset for Multiple Sclerosis, demonstrating superior reconstruction quality and clinical relevance.

Strengths and weaknesses

Strengths:

  1. Originality: The transition from "one-to-one" to "many-to-one" diffusion bridges is a significant conceptual leap. The multi-bridge framework effectively addresses the information loss inherent in standard conditional diffusion models.
  2. Quality: The mathematical derivation is rigorous. The introduction of the Hybrid Estimator is a particularly clever engineering solution to the numerical instability (SNR degeneracy) that occurs near the final diffusion steps.
  3. Significance: The application to MRI (FLAIR prediction) provides strong evidence of the model's utility in medical imaging. Using downstream task validation (lesion volume estimation) to prove clinical relevance is a highly effective way to demonstrate the model's practical value.
  4. Clarity: The paper is well-structured, moving logically from the problem definition to mathematical formulation, then to empirical validation.

Weaknesses:

  1. Source Independence Assumption: The model relies on the assumption of conditional independence across sources given the target (Equation 9). While common, the paper could benefit from a brief discussion on how the model behaves when sources are highly correlated or redundant.
  2. Missing Source Robustness: The authors acknowledge that the model assumes a fixed set of sources. In real-world clinical settings, a specific modality (e.g., T2) might be missing. Exploring how the model handles "missing" sources would significantly increase the work's impact.
  3. Comparison Scope: While the current baselines (DPS, CDE, I2SB) are well-chosen, the paper would benefit from a broader comparison with other existing multi-source or multi-modal diffusion frameworks. Comparing MB-DDPM with methods like "Multi-Source Domain Adaptation by Causal-Guided Adaptive Multimodal Diffusion Networks" would help further clarify the unique advantages of the multi-bridge architecture.
Questions
  1. Comparative Analysis: Could the authors include a comparison with other multi-source/multi-modal diffusion methods? Specifically, how does MB-DDPM differ from methods that use causal-guided or adaptive multimodal fusion?
  2. Source Dynamics: In the case of highly conflicting source information (e.g., two sources providing contradictory spatial data), how does the model prioritize information? A qualitative example of "conflict resolution" would be very insightful.
  3. Generalizability: While the MRI results are compelling, could you briefly elaborate on why the "multi-bridge" design is uniquely suited for medical data compared to other multi-modal fusion techniques?
  4. Missing Modalities: How would the model perform if one of the KK sources is missing during inference? Is there a way to make the framework robust to variable input counts?
Limitations

Yes. The authors correctly identify the assumption of a fixed set of sources and the conditional independence of sources. However, the authors could further discuss the potential for "source conflict"—specifically, how the model behaves when two sources provide contradictory information about the target.

Final justification

The authors provided a clear rebuttal with additional data to address the questions raised. Their response sufficiently clarified my doubts regarding source dynamics, missing modalities, and baseline comparisons. Since the initial questions have been properly resolved through these clarifications, the original positive assessment remains valid. I will maintain my score at 5 to support the acceptance of this submission.

Formatting concerns

None

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

We warmly thank the reviewer for their suggestions.

1. W1 We thank the reviewer for raising the important issue of violations of the conditional independence assumption in Eq. (9). We agree that in practical applications, such as multi-contrast MRI, different acquisitions may share correlated artifacts due to patient motion, scanner effects, or acquisition protocols.

To investigate this issue, we performed additional experiments considering both redundant and correlated sources. First, to investigate the addition of a redundant source, we added an additional source identical to an existing source in the source set (answer 2. to reviewer KN5R). The resulting performance change was negligible.

Second, we evaluated the effect of correlated source noise. The strong empirical performance of MB-DDPM on MRI suggests that moderate violations of this assumption, potentially on some subject, do not prevent the method from being effective. We also performed an analysis to investigate this point. Specifically, given two observations of the same target, we generated correlated degradations as:

xTk=x0+σ2(ρϵs+1−ρϵk),\mathbf{x}^k_T=\mathbf{x}_0+\sigma^2(\sqrt{\rho}\epsilon_s+\sqrt{1-\rho}\epsilon_k),

where ρ\rho controls the degree of correlation between sources, ϵs\epsilon_s and ϵk\epsilon_k are gaussian(0,1) noise. Increasing ρ\rho progressively violates the conditional independence assumption in Eq. (9). We observed that reconstruction quality decreases as the correlation increases. This result is expected because MB-DDPM is trained under the assumption that each source provides conditionally independent evidence about the target; correlated artifacts introduce a mismatch between the training and inference distributions.

These results clarify the scope of MB-DDPM. While the method can tolerate weak violations of the conditional independence assumption, increasing source correlation progressively reduces the benefit of using multiple observations. Under strong correlation, the additional source may even degrade performance relative to using a single source, reflecting the mismatch between the assumed and actual source distributions. This behaviour is expected, as highly correlated sources provide little additional information while introducing correlated errors that are not modelled by the current formulation. Extending MB-DDPM to explicitly model correlated source processes is an interesting direction for future work.

We will include this analysis in Section 4 and the limitations in section 5.

Setting MSE ↓ SSIM ↑ PSNR ↑ FID ↓ LPIPS ↓
One noisy source 0.005466 21.880 0.7542 12.118 0.2268
Two noisy sources: Conditionally independent (ρ=0\rho=0) 0.004720 (-13.65%) 22.512 (+2.89%) 0.7731 (+2.51%) 12.551 (+3.57%) 0.2171 (-4.30%)
Two noisy sources: Weak correlation (ρ=0.1\rho=0.1) 0.005537 (+1.31%) 21.773 (-0.49%) 0.7526 (-0.21%) 13.533 (+3.42%) 0.2522 (+11.19%)
Two noisy sources: Strong correlation (ρ=0.5\rho=0.5) 0.005943 (+8.73%) 21.511 (-1.69%) 0.7261 (-3.72%) 16.110 (+32.94%) 0.2548 (+12.32%)

2. W2/Q4 We thank the reviewer for the suggestion to make our model flexible to missing sources. To be able to account for missing sources, we propose to modify the training pipeline. During training, a missing source is replaced by an image with all pixel values set to −1-1, and an additional binary missing-source indicator is provided to the U-Net. Specifically, this indicator vector contains one value per source, where a value of 11 indicates that the corresponding source is missing and a value of 00 indicates that it is available. The indicator is projected and incorporated into the U-Net conditioning layers, allowing the network to distinguish between an actual source observation and a missing input.

In Section 4.1, we evaluate MB-DDPM trained with four source degradations: Gaussian noise, Gaussian blur, JPEG compression (quality factor 5), and 4×4\times bicubic super-resolution (SR4x) on CIFAR-10. Based on our Shapley-value analysis (Appendix E.1.3), Gaussian blur is highly informative.

We conducted an experiment to evaluate the missing-source framework. During training Gaussian blur is randomly removed with a probability of 50%, and the same missing probability is used at inference.

The results show that MB-DDPM can adapt to missing source modalities when trained with the proposed missing-source strategy. Compared with the standard setting where all four sources are always available (MSE = 0.0007, LPIPS = 0.0438), removing the Gaussian blur source entirely causes the largest degradation (MSE = 0.0042, LPIPS = 0.1922), as the model loses a major source of structural information. However, when the model is trained with Gaussian blur randomly missing 50% of the time, the degradation is substantially reduced (MSE = 0.00215, LPIPS = 0.1057), demonstrating that the proposed training strategy enables MB-DDPM to better adapt to missing informative sources.

These results demonstrate that MB-DDPM can adapt to missing inputs, while the remaining performance is naturally bounded by the amount of observations still available. We will report this analysis in Section 4 and conclusion in Section 5.

Setting MSE ↓ SSIM ↑ PSNR ↑ FID ↓ LPIPS ↓
4 sources 0.000695 31.417 0.9626 5.794 0.0438
3 sources (no Gaussian blur) 0.004260 23.132 0.7896 27.750 0.1922
4 sources (Gaussian blur, 50% missing) 0.002154 27.096 0.8901 17.111 0.1057

3. W3/Q1 Thank you for pointing us to "Multi-Source Domain Adaptation by Causal-Guided Adaptive Multimodal Diffusion Networks" [4]. Although both methods involve multiple sources and diffusion models, they address different learning problems.

The method of [4] is proposed for multi-source domain adaptation. It assumes access to labelled source domains and unlabelled target-domain samples, and employs diffusion models together with causal-guided adaptive multimodal fusion to learn domain-invariant representations for downstream classification. Consequently, the diffusion model is used as a feature generation and domain adaptation mechanism, while the final objective is label prediction.

In contrast, MB-DDPM addresses a conditional image reconstruction problem. Given multiple degraded observations of the same underlying image, the objective is to recover the corresponding clean image through the proposed multi-bridge diffusion process. No class labels, domain adaptation objective, or feature alignment stage are involved. Instead, the core contribution of MB-DDPM is the formulation of multiple bridge processes and their joint reverse diffusion process, which enables information from multiple image sources to be fused throughout the denoising trajectory.

For this reason, we believe that [4] is not a directly comparable baseline, as it does not address conditional image reconstruction or image-to-image translation. We are nevertheless happy to include a discussion in Appendix D highlighting the differences between causal-guided multimodal fusion for domain adaptation and the proposed multi-bridge formulation.

Regarding multi-source diffusion models for image reconstruction, we believe the selected baselines (DPS, CDE, CDM and I2SB) are the most relevant comparisons, as they all perform diffusion-based conditional image reconstruction from conditional observations (here taken to be multiple images).

[4] Cai et al. (2025) Multi-Source Domain Adaptation by Causal-Guided Adaptive Multimodal Diffusion Networks. International Journal of Computer Vision

4. Q2/L1 Concerning conflicting source information, see Answer 2. to reviewer KN5R

5. Q3 We thank the reviewer for this insightful comment. A key strength of the proposed multi-bridge formulation is its generality: it is not tied to a specific imaging modality, but is designed for settings where multiple observations provide complementary information about a shared target. This property makes MB-DDPM naturally suited for multi-contrast MRI, where different contrasts capture complementary tissue properties, while also enabling applications beyond medical imaging. We demonstrate this versatility through experiments on both natural-image and medical-image datasets, showing that the framework can effectively handle diverse multi-source reconstruction scenarios.

The multi-bridge formulation is particularly well suited to multi-contrast MRI because the different contrasts (e.g., T1, T2, and PD) image the same underlying anatomy while emphasizing complementary tissue properties. Our probabilistic formulation explicitly models these complementary observations as multiple sources conditioned on a common target, allowing information from all available contrasts to be integrated in a principled manner during inference.

To clarify the intended scope of the method, we have added a discussion in the conclusion emphasizing that MB-DDPM is a general framework applicable beyond medical imaging. Potential application domains include remote sensing (e.g., combining optical, multispectral, or SAR imagery), and computational photography or image restoration from multiple degraded observations. More generally, MB-DDPM is applicable whenever multiple sources provide complementary information about a common target and satisfy the conditional-independence assumptions underlying our probabilistic formulation.

Reviewer L3Qo · CommentOpenReview ↗

I thank the authors for the rebuttal. The responses have clarified my initial concerns. I recommend incorporating these explanations into the final version to enhance the paper. I will maintain my original score.

Reviewer KN5ROpenReview ↗
Rating
4/6
Confidence
4/5
Quality
3/4
Clarity
2/4
Significance
2/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The paper proposes Multi-Bridge DDPM (MB-DDPM), a diffusion-bridge framework for many-to-one image translation where multiple source observations are used to generate a single target image. The method constructs separate stochastic bridges from the target to each source, then couples them through a shared reverse process that aggregates information across sources. It derives a variational training objective and introduces conditional, marginal, and hybrid estimators for the target image to balance statistical efficiency and numerical stability.

Empirically, the paper evaluates MB-DDPM on multi-source image restoration for CIFAR-10 and ImageNet, and on medical image translation for multiple-sclerosis brain MRI, predicting FLAIR from T1, T2, and PD contrasts. The results show improved reconstruction and perceptual metrics over several diffusion-based baselines, and the MRI experiments further assess downstream clinical relevance via lesion-volume estimation, where predicted FLAIR images yield high agreement with estimates from real FLAIR.

Strengths and weaknesses

Strengths The paper is technically solid and provides a principled formulation of multi-source diffusion bridges. A strength is the theoretical development: the authors derive the multi-bridge forward and reverse processes, provide a variational bound, and justify the proposed conditional, marginal, and hybrid estimators with formal propositions and proofs. This makes the method more convincing than a heuristic fusion strategy.

Weaknesses / Concerns Clarity of “complementary” vs. “heterogeneous” sources. The terminology around the source inputs could be clearer. In the abstract, the paper frames the setting as one where “multiple sources provide complementary information about a single target,” while the conclusion describes the method as integrating “heterogeneous sources.” These are related but not identical concepts: heterogeneous sources may simply differ in modality or degradation type, whereas complementary sources specifically provide non-redundant useful information. The datasets used in the experiments largely fit the complementary-source setting, e.g. multiple MRI contrasts or multiple degradations of the same clean image. It would strengthen the clarity and scope of the paper if the authors explicitly distinguished these notions and discussed whether MB-DDPM is expected to work when sources are heterogeneous but not necessarily complementary. An experiment or ablation on less complementary or conflicting source combinations could help clarify this limitation.

Baseline comparison could be stronger. The empirical comparison is somewhat limited by the choice of baselines. While the included baselines cover score-based inverse-problem methods, conditional diffusion, and diffusion bridge models, the conditional diffusion baseline appears relatively generic. The paper would be more convincing if it compared against stronger or more recent conditional image-generation/image-translation approaches, or at least explained why such methods are not directly applicable to the multi-source setting. For example, modern image-conditioned diffusion/adaptation methods such as IP-Adapter-style conditioning or stronger latent diffusion backbones(SD3, etc) could provide more competitive references, though they may require careful adaptation for fair comparison. Without such comparisons or a clear justification, the “state-of-the-art” claim may be harder to assess.

Questions

Clarify the intended scope: complementary vs. heterogeneous sources. The paper alternates between describing the setting as one with complementary sources and one with heterogeneous sources. Could the authors clarify whether MB-DDPM assumes that all sources provide useful complementary information, or whether it is also intended for heterogeneous sources that may be redundant, weakly informative, or even conflicting? My evaluation would improve if the authors clearly define this distinction and discuss when additional sources may hurt rather than help.

Assess robustness to non-complementary or conflicting sources. The current experiments mostly use source sets that are naturally complementary: multiple MRI contrasts or multiple degraded views of the same clean image. A small ablation where one source is uninformative, redundant, or mismatched would help clarify the method’s limitations. For example, replacing one degradation source with a heavily corrupted or randomly paired source could show whether the reverse process learns to downweight unreliable inputs. This would address whether MB-DDPM is robust to general heterogeneous-source settings, not only complementary ones.

Strengthen or justify the baseline selection. The comparison includes DPS, CDE, CDM, and I2SB, but the conditional diffusion baseline appears relatively generic. Could the authors explain why stronger or more recent conditional image-generation methods are not included or are not applicable? For example, image-conditioned diffusion/adaptation methods such as IP-Adapter-style conditioning or stronger latent diffusion backbones(SD3) may be relevant baselines if adapted carefully. My evaluation would improve if the authors either add a stronger conditional diffusion baseline or provide a convincing explanation of why such comparisons would be unfair or technically incompatible with the proposed multi-source bridge setting.

Report sensitivity to the hybrid estimator design. The hybrid estimator is an important part of MB-DDPM, but its behavior depends on the SNR-based interpolation and the snr_threshold parameter. Could the authors clarify how sensitive the main results are to this choice, especially on MRI and ImageNet beyond the CIFAR-10 tuning study? A small sensitivity analysis or discussion would help determine whether the method is robust or requires task-specific tuning.

Clarify clinical evaluation and possible leakage risks. For the MRI experiment, the downstream lesion-volume evaluation is a strong point. Could the authors provide more detail on whether the lesion segmentation model was trained independently of the MB-DDPM train/test split, and whether any scans or patients overlap between segmentation-model training and MB-DDPM test evaluation? My confidence in the clinical claims would increase if the authors rule out leakage and clarify the independence of the downstream evaluation pipeline.

Limitations

Not fully. The authors mention some important limitations, such as requiring a fixed set of sources at inference and assuming conditional independence across sources given the target. However, several limitations could be discussed more explicitly:

The paper should clarify the distinction between complementary and heterogeneous sources, and discuss whether MB-DDPM remains reliable when sources are weakly informative, redundant, or conflicting. The method appears evaluated mainly in settings where the sources are naturally useful for the target; a discussion of failure modes with non-complementary or missing sources would be helpful. For the MRI application, the authors should more clearly discuss clinical deployment risks, e.g. whether synthesized FLAIR could miss or hallucinate lesions, and whether predicted images should be used only as decision support rather than as replacements for acquired scans. The limitations of the downstream lesion-volume evaluation should be clarified, including generalization beyond the NO.MS dataset and dependence on the segmentation model.

Formatting concerns

No.

1 comment
Authors · RebuttalOpenReview ↗
Rebuttal

We warmly thank the reviewer for valuable suggestions.

1. W§1/Q§1 We agree and will revise the terminology throughout the paper to use "complementary sources" when referring to our primary problem setting. For example, in the conclusion, we will replace "integrates heterogeneous sources" with "integrates complementary sources."

We added a new ablation analysis in Section 4 evaluating the robustness of MB-DDPM to sources that may be redundant, weakly informative, corrupted, or conflicting (described in next point). Our results show that MB-DDPM is largely robust to such sources, with only modest performance degradation.

Thus, MB-DDPM is primarily designed for sources that provide complementary information, but it does not require every source to be strictly complementary and can tolerate unreliable sources. We will add this conclusion in Section 5.

2. W§1/Q§2 We investigate whether adding an unreliable source to an otherwise informative source set negatively affects the reconstruction quality, or whether the model can effectively downweight the additional source during the reverse diffusion process.

To this end, we conducted an ablation study on CIFAR-10. As our baseline, we consider three-sources: Gaussian noise, Gaussian blur, and 4×4\times bicubic super-resolution. We then augmented this source set with one additional source representing four different challenging scenarios: (i) a heavily corrupted source (JPEG compression, QF 5), (ii) a redundant source (repeated Gaussian blur), (iii) an uninformative source (random uniform noise), and (iv) a conflicting source (Gaussian-blur from a different observation).

The results are reported below, with the values in parentheses indicating the relative change with respect to the original three-source setting.

MSE↓ SSIM↑ PSNR↑ FID↓ LPIPS↓
3 sources 0.000661 0.9642 31.638 5.761 0.0420
3 sources + 1 corrupted 0.000695 (+5.24%) 0.9626 (-0.17%) 31.417 (-0.70%) 5.794 (+0.57%) 0.0438 (+4.15%)
3 sources + 1 redundant 0.000659 (-0.27%) 0.9642 (+0.05%) 31.653 (+0.05%) 5.694 (-1.17%) 0.0421 (+0.11%)
3 sources + 1 uninformative 0.000701 (+6.05%) 0.9625 (-0.18%) 31.385 (-0.80%) 6.010 (+4.32%) 0.0443 (+5.39%)
3 sources + 1 conflicting 0.000695 (+5.14%) 0.9627 (-0.16%) 31.420 (-0.69%) 5.942 (+3.14%) 0.0439 (+4.43%)

Overall, these results indicate that MB-DDPM is reasonably robust to the inclusion of non-complementary sources. In particular, adding a redundant source has essentially no effect on performance. The addition of corrupted, uninformative, or conflicting sources results in a modest degradation, with changes of at most +6.05% in MSE, -0.80% in PSNR, -0.18% in SSIM, +4.32% in FID, and +5.39% in LPIPS. We will report the result of this analysis in section 4 and report the limitations in section 5.

3. W§2/Q§3 Both IP-Adapter [1] and SD3 [2] were developed for text-to-image generation rather than image-to-image reconstruction. Their conditioning mechanisms are therefore fundamentally different from the setting considered in this work.

SD3 [2] is not directly applicable to our problem for several reasons. First, SD3 is formulated as a text-conditioned generative model based on a Multimodal Diffusion Transformer (MMDiT), where the primary conditioning signal is provided by text embeddings produced by pretrained language encoders. Our setting instead requires conditioning on multiple degraded observations of the same unknown image. Adapting SD3 would therefore require replacing its conditioning pipeline with a fundamentally different multi-image conditioning mechanism, making the resulting model substantially different from the original architecture.

Second, SD3 operates in the compressed latent space of a pretrained VAE following the latent diffusion framework [3], which is well suited for semantic image synthesis but less appropriate for reconstruction tasks that require preserving fine-grained, instance-specific details. In our applications, particularly MRI reconstruction, the objective is not to generate a semantically plausible image but to faithfully recover the exact target anatomy, including subtle structural details and clinically relevant features (e.g., small lesions), from multiple observations. Such fine-grained information can be degraded by VAE compression, making comparisons with SD3 less meaningful than comparisons with methods specifically designed for conditional image reconstruction.

We also investigated an IP-Adapter-style conditioning mechanism [1]. Specifically, following Section 3.2.2 of [1], the source images (xT1:K\mathbf{x}_T^{1:K}) were encoded into image tokens and injected into the U-Net through cross-attention layers. This differs from MB-DDPM, CDE, and CDM, where the source images are provided directly to the denoising network through concatenation with the noisy states (xt1:K\mathbf{x}_t^{1:K}).

In our experiments, the IP-Adapter-style model generated visually plausible images that were semantically consistent with the source inputs (e.g., degraded images of a cat produced realistic cat images), but it failed to preserve the identity of the underlying instance. Instead, it synthesized a new image sharing similar semantic characteristics with the conditioning images. This behaviour is expected, as IP-Adapter was designed to inject high-level semantic and stylistic guidance into text-to-image diffusion models rather than to preserve pixel- or instance-level correspondence between the conditioning images and the output. In contrast, our reconstruction problem requires recovering the specific clean image associated with the degraded observations. Direct conditioning through concatenation therefore provides a substantially stronger mechanism for preserving instance-level information. We can include these experimental results in the appendix if the reviewer considers such a comparison useful.

[1] Hu et al. (2023). IP-Adapter: Text Compatible Image Prompt Adapter for Text-to-Image Diffusion Models. arXiv

[2] Esser et al. (2024). Scaling Rectified Flow Transformers for High-Resolution Image Synthesis. arXiv

[3] Rombach et al. (2022). High-Resolution Image Synthesis with Latent Diffusion Models. CVPR

4. Q§4 Concerning snr_threshold, see answer 1. to reviewer Zi6R

5. Q§5 We thank the reviewer for raising this important point regarding the independence of the downstream evaluation pipeline. The lesion segmentation model was completely independent of MB-DDPM training and was not used for model selection, training, or hyperparameter tuning. MB-DDPM was trained only using the available MRI contrasts (T1, T2, and PD) and the target FLAIR images, without access to lesion masks, lesion volumes, or segmentation outputs.

For the downstream evaluation, we used the pretrained segmentation model from Sun et al [30] as a fixed evaluation tool. The same segmentation model was applied to both the true FLAIR images and the MB-DDPM-predicted FLAIR images, together with the corresponding T1 images. Therefore, the objective of this analysis was not to assess the absolute segmentation accuracy of the model, but rather to measure whether lesion-related information is preserved after FLAIR prediction.

We acknowledge that we do not have access to the exact training cohort used for the external segmentation model and therefore cannot completely exclude possible subject overlap. However, because the segmentation model was not involved in MB-DDPM development and was applied identically to both real and predicted FLAIR images, the reported comparison remains an evaluation of information preservation rather than an evaluation of segmentation model generalization.

We have revised the Appendix E.3 to clarify this limitation.

[30] Yun et al. (2025) An automated deep learning segmentation tool for accurate and generalizable ms lesion quantification. Multiple Sclerosis Journal, 31(3):179,

6. L§1 Concerning missing sources, see answer 2. to reviewer L3Qo.

7. L§1 We thank the reviewer for this important comment concerning clinical deployment risks.

In contrast to unconditional generation, MB-DDPM reconstructs FLAIR images conditioned on the available MRI contrasts (T1, T2, and PD), which provide subject-specific anatomical and structural information. This conditioning may reduce ambiguity during synthesis by constraining the generated image to be consistent with the available observations; however, it does not completely eliminate the possibility of missing or hallucinated findings.

To assess whether clinically relevant lesion information is preserved, we evaluated lesion volumes obtained from the predicted FLAIR images and observed strong agreement with those measured from the true FLAIR images (Figure 6).

While these results provide encouraging evidence that the predicted FLAIR retain clinically relevant information, they do not rule out the possibility of clinically significant errors at the individual lesion level. Consequently, we do not advocate using predicted FLAIR images as a replacement for acquired scans, but rather as an adjunct that may support clinical interpretation when appropriate. Therefore, the current results should not be interpreted as demonstrating clinical generalization. We have revised Section 5 to explicitly acknowledge these limitations.

Comments on the paper

1 comment
Authors · CommentOpenReview ↗

General response to all reviewers

We sincerely thank all three reviewers for their thoughtful, rigorous feedback and constructive suggestions, which have significantly strengthened both the theoretical foundation and empirical validation of our work. Below is a detailed summary of the key findings, newly added results, and revisions resulting from the rebuttal process, structured according to the main themes of the meta-review:

  1. Input Scope & Conflicting Sources:

    • Robustness to Unreliable and Non-Complementary Sources: We showed that adding a redundant source has no impact on performance, while adding heavily corrupted, uninformative, or conflicting sources leads to only minor performance degradations, demonstrating strong robustness to unreliable inputs. (reviewer KN5R, Answer 2)

    • Impact of Source Correlation Violations: We analyzed violations of the conditional independence assumption, showing that while MB-DDPM tolerates mild source correlations, strong correlations leads to important discrepancies between the assumed and actual source distributions that degrade performance. Conditional-independence of the sources remains a critical assumption and alleviating it represents a direction for future work. (Reviewer L3Qo, Answer 1)

  2. Baseline Justifications & Comparison Scope:

    • Text-to-image backbones: We clarified that text-to-image backbones like SD3 are structurally ill-suited for image conditioning and for instance-level reconstruction due to VAE compression loss. Furthermore, empirical tests with an IP-Adapter-style cross-attention conditioning mechanism showed that it synthesizes new semantic variations rather than preserving instance-level structural fidelity, confirming the necessity of MB-DDPM's direct concatenation design. (reviewer KN5R, Answer 3)
    • We highlighted the fundamental distinction between causal-guided multimodal diffusion networks (e.g., Cai et al., 2025), which focus on feature alignment for label prediction, and MB-DDPM, which targets exact conditional image reconstruction. (L3Qo, Answer 3)
  3. Missing Modalities & Hyperparameter Sensitivity:

    • Adaptability to Missing Modalities: By incorporating a missing-source binary indicator as an additional input, MB-DDPM can effectively adapt to missing modalities at inference. (Reviewer L3Qo, Answer 2)
    • Sensitivity to Hybrid Estimator Hyperparameters: We demonstrated that the model’s performance remains robust and consistent for MRI and ImageNet across different values of snr_threshold. (Reviewer Zi6R, Answer 1)
  4. Validation Details & Presentation:

    • We clarified that the downstream MS lesion segmentation model used for evaluation was completely independent of the MB-DDPM training pipeline (no shared loss, tuning, or access to lesion masks), confirming that the lesion volume agreement reflects true clinical information preservation. (KN5R, Answer 5)
    • We fixed the typos and clarified the disagreement metrics' normalization. (Zi6R, Answer 2)

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.

Missing a submission?

Loading the discussion…