Aegis: Generative Gradient Masking for Privacy-Preserving Medical Federated Learning
Chaoyu Zhang, Shanghao Shi, Heng Jin, Ning Wang, Thomas Hou, Wenjing Lou
TL;DR. Medical FL can leak patient images through shared updates, even with secure aggregation. We add synthetic client-side masking gradients to collapse reconstructions while preserving utility and the FL protocol.
Abstract. Federated learning (FL) has become a foundational paradigm for multi-institutional medical AI, allowing hospitals and research centers to jointly train diagnostic models without exchanging patient records. This privacy promise, however, is increasingly contested: a malicious or honest-but-curious server can launch model inversion attacks (MIAs) that reconstruct private patient images directly from shared model updates, and recent scalable, closed-form attacks penetrate even secure aggregation at clinically realistic batch sizes. Existing defenses face an unsatisfactory dilemma. Gradient-perturbation methods such as differential privacy and pruning trade away the diagnostic accuracy on which clinical reliability depends, while cryptographic protocols add system complexity yet still leave updates exposed to these scalable attacks. We propose Aegis, a principled client-side defense that breaks this dilemma without perturbing patient data or modifying the FL protocol. Our key insight is that the success of every known MIA is fundamentally bounded by the local batch size relative to the model's leakage capacity; once this limit is exceeded, distinct samples collide and reconstructions collapse into indistinguishable mixtures. Aegis turns this universal bottleneck into a defense: each client superimposes onto its real update a masking gradient computed on locally synthesized, task-relevant data, deliberately pushing the effective batch beyond the attack's recovery capacity. We complement the design with theoretical convergence guarantees under standard convex assumptions and evaluate Aegis on MNIST, CIFAR-10, and three MedMNIST modalities (chest X-ray, abdominal CT, colon pathology). Aegis neutralizes three state-of-the-art MIAs while preserving model utility and incurring only modest overhead, offering a practical privacy primitive for medical FL.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (poster) · 4 reviews · OpenReview
Updated 25 Nov 2026, 03:49 UTC.
- Decision
- Accept (poster)
Read decision
Meta-review
The authors tackle the problem of model inversion attacks in the context of federated learning; and motivate their work primarily for medical domain/applications. The proposal is based on gradient mixing strategy that relies on using a synthetic data at each client to generate fake/synthetic gradients that break the batch size limits when pooled across federation; which essentially drives non-identifiability of the input samples. The proposal is evaluated on various standard datasets (including 3 medical ones).
The paper received valuable feedback, and the reviewers highlighted various critical pieces. I would request the authors to take a read of the comments/questions and address them to improve the case for publication. Specifically, the comments are on missing technical details (e.g., hyperparameter choices/tuning on attack bins size), a potential missing baseline, clarity on generator configuration, and mainly the generalization capacity to more in the wild medical data beyond medMNIST and possibly needing more quantitative evidence here (especially given that the motivation is anchored on medical settings).
Final justification
The authors addressed the critical concerns and issues raised by the reviewers; specifically on the technical details, missing baseline and clarifications on evaluations setups/interpretations; and they provided sufficient evidence on generator capacity (related to generalization). There is still the question of level of impact for the work; but as things stand, the authors' made the case for publication.
I request the authors to appropriately reflect any relevant changes/additions to the final camera ready (tables, results etc.) so we capture the commentary that happened here via author-reviewer discussions.
Read meta-review
Meta-review
The authors tackle the problem of model inversion attacks in the context of federated learning; and motivate their work primarily for medical domain/applications. The proposal is based on gradient mixing strategy that relies on using a synthetic data at each client to generate fake/synthetic gradients that break the batch size limits when pooled across federation; which essentially drives non-identifiability of the input samples. The proposal is evaluated on various standard datasets (including 3 medical ones).
The paper received valuable feedback, and the reviewers highlighted various critical pieces. I would request the authors to take a read of the comments/questions and address them to improve the case for publication. Specifically, the comments are on missing technical details (e.g., hyperparameter choices/tuning on attack bins size), a potential missing baseline, clarity on generator configuration, and mainly the generalization capacity to more in the wild medical data beyond medMNIST and possibly needing more quantitative evidence here (especially given that the motivation is anchored on medical settings).
Final justification
The authors addressed the critical concerns and issues raised by the reviewers; specifically on the technical details, missing baseline and clarifications on evaluations setups/interpretations; and they provided sufficient evidence on generator capacity (related to generalization). There is still the question of level of impact for the work; but as things stand, the authors' made the case for publication.
I request the authors to appropriately reflect any relevant changes/additions to the final camera ready (tables, results etc.) so we capture the commentary that happened here via author-reviewer discussions.
1 comment
- Rating
- 5/6
- Confidence
- 3/5
- Quality
- 3/4
- Clarity
- 4/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper presents Aegis, a client-side defense for privacy-preserving medical FL. It targets model inversion attacks that can reconstruct private training images from shared updates, including recent attacks that still work even with secure aggregation. The main idea is to use locally generated synthetic data to create an extra masking gradient (where in medical use case data samples are scarce), and then add it to the real client update before sending it to the server. This increases the effective batch size seen by the attack and makes reconstruction collapse into mixed or blurred outputs instead of individual patient samples. The paper evaluates Aegis on MNIST, CIFAR-10, and several MedMNIST medical datasets, and reports that it reduces attack success while keeping model utility close to the no-defense case.
Strengths and weaknesses
The main idea, Aegis, is simple and nice, each client uses synthetic data to make a masking gradient, and then adds this to the real update before sending it. The method is easy to understand, and it does not need a big change in the FL protocol.
The idea of making the effective batch larger is intuitive, and the experiments show that the method can reduce reconstruction quality while keeping utility close to the baseline. Another strength is originality: the defense is not just adding random noise, but using generated data in a more structured way.
A weakness is the quality of the evaluation in non-IID settings. In practice, different hospitals often have very different amounts of samples, and this should be tested more directly. I think using a Dirichlet split (i.e., https://arxiv.org/pdf/2102.02079) would make the evaluation more realistic and stronger. This matters because the method depends on local training and on the relation between real data and synthetic masking, so the behavior can change when some clients have much less data than others. It is also possible that clients with fewer samples are easier to attack, or at least need different masking strength, assuming some clients have very different , which would have some effects in Algorithm A.1. Writing in the paper “We use non-IID FedAvg” does not help to understand what the clients’ real distributions are.
A weaknesses it’s the comparaison with cryptographic solution, in [23] (Model inconsistency attack) the solution called conditional secure aggregation has been introduced, the idea it’s to add integrity mechanism in the secure aggregation protocol, like using the hash of the local client parameters. For example in https://eprint.iacr.org/2025/574 they proposed to use incremental hashing over the model parameters to efficiently compute the hash. It adds extra communication (it scales with the number of clients), and requires extra computation. I think that a comparaison also with some integrity method that follows te conditional secure aggregation idea would improve the final paper.
Overall, I think the paper has a good and original idea, and the main mechanism is promising. The writing is clear enough and the experimental results are encouraging. But the evaluation should be broader and more realistic, especially for non-IID hospital data, before the method can be seen as fully convincing for healthcare FL. And it should also expanded the cryptography solution comparaison.
Questions
My main questions are:
- The paper should evaluate a deeper non-IID use case, especially with different dataset sizes, which is a common case in real-world healthcare applications. What is the current setup of D_i for all clients i?
- Comparing with some conditional secure aggregation technique to see the computation comparison would improve the final paper.
- Can it also be evaluated with non-CNN neural networks, like ViT?
Limitations
yes
Final justification
The authors have addressed all my concerns, and the work presents several interesting ideas.
Formatting concerns
no
3 comments
We thank the reviewer for the constructive comments.
1. Evaluation under realistic non-IID partitions
We agree that non-IID evaluation is important. Following Li et al., Federated Learning on Non-IID Data Silos: An Experimental Study, we add distribution-based label skew with and , quantity-based label skew with two classes per client (#C=2), noise-based feature skew , and quantity skew . Our original setting is already non-IID and closest to their quantity-based label-skew family: 100 clients have disjoint data, each restricted to at most five classes, with 10% participation. All other settings remain fixed, including , , and .
Table 1. Non-IID sensitivity of Aegis. ACC and RR are percentages.
| Partition | Chest ACC↑ | Chest RR↓ | Chest PSNR↓ | Chest SSIM↓ | OrganA ACC↑ | OrganA RR↓ | OrganA PSNR↓ | OrganA SSIM↓ | Path ACC↑ | Path RR↓ | Path PSNR↓ | Path SSIM↓ |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Original: #C≤5 | 55.5 | 9.50 | 18.70 | 0.46 | 58.8 | 11.63 | 20.10 | 0.51 | 57.2 | 9.38 | 17.30 | 0.38 |
| Label Dir(0.5) | 58.8 | 9.38 | 18.61 | 0.45 | 62.1 | 11.48 | 19.95 | 0.50 | 60.5 | 9.25 | 17.18 | 0.37 |
| Label Dir(0.1) | 53.8 | 9.62 | 18.82 | 0.47 | 57.0 | 11.78 | 20.25 | 0.52 | 55.4 | 9.51 | 17.42 | 0.39 |
| Label qty. #C=2 | 43.6 | 9.71 | 18.91 | 0.47 | 46.4 | 11.91 | 20.37 | 0.52 | 44.8 | 9.62 | 17.54 | 0.39 |
| Feature Gau(0.1) | 59.5 | 9.94 | 19.05 | 0.48 | 62.8 | 12.08 | 20.51 | 0.53 | 61.2 | 9.78 | 17.72 | 0.40 |
| Quantity Dir(0.5) | 60.2 | 9.44 | 18.66 | 0.46 | 63.5 | 11.57 | 20.04 | 0.51 | 61.9 | 9.34 | 17.28 | 0.38 |
The hard two-class constraint causes the largest ACC drop. Dirichlet label skew is milder at 0.5 and more concentrated at 0.1; feature and quantity skew retain broad label coverage and therefore outperform our original five-class cap. Defense data use only client-visible labels and remain within the same client-side distribution bound, so they do not remove the non-IID skew. Privacy remains stable because each partition retains . We will cite the study and include these experiments.
2. Comparison with conditional secure aggregation
We thank the reviewer for pointing us to this important work and will cite and discuss it. MPC-based secure aggregation hides each individual update as ciphertext; reconstruction instead operates on the plaintext aggregate/global update. That aggregate is numerically identical with or without secure aggregation, so an empirical comparison would reproduce the same RR/PSNR/SSIM. Conditional secure aggregation adds integrity checks against model inconsistency, whereas our threat model allows the server to send the same crafted model to all clients. The mechanisms therefore address complementary attack surfaces.
3. Evaluation beyond CNN backbones
We replace the task backbone while retaining the original non-IID partition, , and the same crafted FC leakage front-end. All classifiers use dataset-native resolution and no classifier pretraining; the low-resolution ViT uses 4×4 patches.
Table 2. Backbone sensitivity under the same Aegis/Robbing-the-Fed setting
| Backbone | Chest ACC↑ | Chest RR↓ | Chest PSNR↓ | Chest SSIM↓ | OrganA ACC↑ | OrganA RR↓ | OrganA PSNR↓ | OrganA SSIM↓ | Path ACC↑ | Path RR↓ | Path PSNR↓ | Path SSIM↓ |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3-layer CNN | 55.5 | 9.50 | 18.70 | 0.46 | 58.8 | 11.63 | 20.10 | 0.51 | 57.2 | 9.38 | 17.30 | 0.38 |
| ResNet-18 | 57.8 | 9.47 | 18.68 | 0.46 | 61.4 | 11.59 | 20.07 | 0.51 | 60.1 | 9.35 | 17.27 | 0.38 |
| ViT-S/4 | 56.4 | 9.54 | 18.74 | 0.46 | 59.9 | 11.67 | 20.14 | 0.51 | 58.4 | 9.42 | 17.35 | 0.38 |
| Swin-T | 57.2 | 9.49 | 18.69 | 0.46 | 60.7 | 11.61 | 20.09 | 0.51 | 59.4 | 9.37 | 17.29 | 0.38 |
The backbone changes ACC, whereas privacy metrics remain within run-to-run variation. Robbing-the-Fed reconstructs from the same crafted first-FC gradients. For an isolated bin, the downstream scalar occurs in both weight and bias gradients and cancels in their ratio. Under Aegis, forces real–synthetic collisions; the backbone may slightly reweight a collided mixture but does not change leakage-bin capacity. The defense is therefore not CNN-specific.
Thanks for the answers:
-
- My concerns are addressed.
- Thanks for the clarification. Please make it clear in the paper the difference between your Threat model (same global model for all clients) and that of [23] (different global model for some clients).
Thank you for your feedback. We will further polish the paper and clearly distinguish our threat model from that of [23] in the final version.
- Rating
- 4/6
- Confidence
- 2/5
- Quality
- 2/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes Aegis: clients leverage a generative model to construct a large-scale synthetic dataset, and during local training they superimpose an additional gradient computed on this synthetic data. This pushes the effective batch size beyond the bin capacity of the linear-leakage layer implanted by the malicious server, causing gradient inversion to collapse into mixed images of multiple samples rather than recover identifiable real medical images. The paper evaluates on MNIST, CIFAR-10, and three MedMNIST datasets, claiming to defend against Robbing-the-Fed, LOKI, and Scale-MIA while maintaining reasonably good model utility.
Strengths and weaknesses
Strengths
- Clear core intuition. Aegis exploits the reliance of linear-leakage attacks on approximately separating samples into leakage bins. Using synthetic-data gradients to induce collisions between samples is conceptually simple and potentially interesting.
Weaknesses
-
Mismatch between the threat model and the defense condition. The server is assumed to control the malicious leakage architecture and hence the number of leakage bins (k). However, the defense is effective only when the combined private and synthetic batch size exceeds the number of attacker-controlled leakage bins, i.e., (B + M_i > k). Thus, the client must know or upper-bound an attacker-controlled quantity (k), which appears incompatible with the stated setting. An adaptive server could increase (k), add a wider leakage branch, or separate real and synthetic samples through selective activations. The paper should either provide a mechanism for bounding or auditing (k), or narrow the threat model accordingly.
-
Limited medical realism. The medical evaluation is restricted to low-resolution MedMNIST benchmarks. It does not establish effectiveness for clinically realistic settings such as high-resolution CT, DICOM studies, 3D volumes, or whole-slide pathology images.
-
Generator assumption is insufficiently justified. The defense depends on synthetic samples being sufficiently task-relevant and overlapping with private samples in the attack-relevant leakage space, but this is not validated convincingly for medical data. If local fine-tuning on private data is required, the paper should clarify whether the generator itself may memorize sensitive samples, what a “sanitized subset” means, and what privacy protection this preprocessing provides.
Questions
Questions
-
How practical is Aegis for resource-constrained medical FL clients? The method requires a local conditional generator, a cached defense set of (M_i=2048) samples, and an additional masking forward-backward pass per local epoch. Could the authors report the total generation, storage, memory, and runtime cost on lower-resource settings, such as CPU-only clients or GPUs with limited memory? It would also be helpful to clarify how the generator is obtained and whether local fine-tuning on private medical data introduces memorization risks.
-
How should a client choose (M_i) when the malicious server can adapt the leakage capacity (k)? The defense relies on (B + M_i > k), but (k) is attacker-controlled and may vary across rounds or leakage architectures. Please clarify whether there is a principled lower bound for (M_i) without knowing (k), and evaluate robustness when the server increases (k) dynamically or uses leakage mechanisms not governed by the same FC-layer bin-capacity condition.
Limitations
yes
Final justification
The authors’ rebuttal regarding limited data and training efficiency has addressed some of my previous concerns. After considering the authors’ responses and their discussion with the other reviewers, I have decided to raise my score.
Formatting concerns
none
3 comments
We thank the reviewer for the constructive comments.
We clarify the assumptions below.
1. Mismatch between the threat model and defense condition
We clarify that is not hidden: it is simply the number of neurons in the first crafted fully connected layer of the broadcast global model. The client receives the complete architecture before local training and reads directly from that broadcast. If the server changes the layer width, the changed is immediately visible. Thus, the client does not need to infer or upper-bound an unknown server-side quantity. We will state this and the scope of the evaluated FC-based linear-leakage attacks explicitly.
2. Limited medical realism
We agree that MedMNIST is a processed benchmark rather than raw clinical data. We use its chest X-ray, abdominal CT, and histopathology tasks to evaluate defense effectiveness and utility impact in a common, controlled medical-FL classification setting. This does not replace validation on full-resolution clinical data. However, Aegis acts on gradients of data already prepared for FL training and is not restricted to MedMNIST resolution. Full-resolution DICOM studies, 3D volumes, and whole-slide pathology are important large-scale extensions.
3. Generator assumption and memorization risk
The reported implementation uses public Stable Diffusion 2.0 with OpenCLIP ViT-H/14, without dataset-specific fine-tuning, a separate medical generator, or test images. Each client uses only locally visible labels to form prompts and a small held-out slice of its training partition for the in-distribution check. An out-of-distribution candidate is discarded and never enters the defense cache or masking update. The generator, held-out slice, and accepted cache remain local; the server receives only the protected model update. Thus, no generator or synthetic/private sample creates a separate server-visible release channel under our threat model. We will clarify this filtering step and trust boundary.
4. Practicality for resource-constrained medical FL clients
Our clients are hospitals, laboratories, or healthcare organizations in cross-silo FL, rather than phones or IoT devices. We therefore assume each institutional client has sufficient compute and memory for local generation and training. For one client, the one-time generation phase runs on a single 10-GB RTX 3080. Generating 2,048 accepted images takes approximately 2.8 hours; they are then reused across all FL rounds. The MedMNIST-size cache occupies only 1.6–4.8 MB as uint8 images (6.4–19.3 MB as float32 tensors). A client need not train a generator from scratch, and optional adaptation is offline. During FL, the generator is unloaded and only one masking pass is added per local epoch. Gradient accumulation uses small physical micro-batches, keeping peak memory within the local training GPU.
Thank you for the explanation. Your clarifications have addressed my concerns, and I am willing to increase my score to 4.
Thank you for your review and valuable feedback!
- Rating
- 4/6
- Confidence
- 2/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 4/4
- Originality
- 4/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper presents a federated learning method that defends model inversion attacks. At the core of the proposed method is imposing mask gradients computed from local synthetic data. Experiments on several public datasets demonstrated the effectiveness the proposed method.
Strengths and weaknesses
Strengths: The idea of masking gradients is novel by leveraging generated data of same distribution is novel. The study has great significance in improving the safety of federated learning.
Weaknesses: The impact of the choice of generative model on reconstruction performance is unclear. The proposed method is limited to defending linear leakage MIAs.
Questions
Could the authors clarify the generative models used in synthesizing the dataset? How much is the computation overhead of the proposed method?
Limitations
I suggest to discuss the different generative model's impact to the model's performance.
Formatting concerns
No
3 comments
We thank the reviewer for the constructive comments.
Generator configuration. The reported implementation uses one pipeline across MNIST, CIFAR-10, and all three MedMNIST modalities: the public Stable Diffusion 2.0 latent-diffusion model with OpenCLIP ViT-H/14. Each client constructs class-aligned prompts only from locally visible labels, resizes/crops candidates to the target tensor layout, and applies a client-side in-distribution filter estimated from a small held-out slice of its training partition. The public checkpoint is used without dataset-specific fine-tuning; no separate medical generator or test image is used. The generator, held-out training slice, and accepted defense cache remain local.
Generator ablation. We additionally evaluate three architecturally diverse alternatives: SDXL 1.0 (text-conditioned latent diffusion), VQ-VAE-2 (hierarchical discrete VAE), and StyleGAN2-ADA (conditional GAN). Each alternative is conditioned or, where needed, adapted using a sanctioned client-side training split; no test image is used. We apply the same locally visible labels, preprocessing, acceptance filter, and cache. All variants use the same 100-client non-IID FedAvg and Robbing-the-Fed configuration (, , ). Generation is offline and cached; online, every variant adds the same masking-gradient pass per local epoch. Thus, the reported online cost is independent of generator family.
Table 1. Generator ablation under the same Aegis/attack configuration. ACC and RR are percentages.
| Generator | Chest ACC↑ | Chest RR↓ | Chest PSNR↓ | Chest SSIM↓ | OrganA ACC↑ | OrganA RR↓ | OrganA PSNR↓ | OrganA SSIM↓ | Path ACC↑ | Path RR↓ | Path PSNR↓ | Path SSIM↓ |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| No defense | 55.8 | 89.06 | 62.40 | 0.94 | 58.6 | 82.81 | 50.60 | 0.89 | 57.3 | 78.13 | 45.20 | 0.86 |
| Stable Diffusion 2.0 | 55.5 | 9.50 | 18.70 | 0.46 | 58.8 | 11.63 | 20.10 | 0.51 | 57.2 | 9.38 | 17.30 | 0.38 |
| SDXL 1.0 | 55.6 | 9.06 | 18.30 | 0.44 | 58.7 | 10.94 | 19.60 | 0.49 | 57.3 | 8.75 | 16.90 | 0.36 |
| VQ-VAE-2 | 55.4 | 10.63 | 19.20 | 0.48 | 58.6 | 12.50 | 20.70 | 0.53 | 57.1 | 10.31 | 17.90 | 0.41 |
| StyleGAN2-ADA | 55.3 | 11.25 | 19.60 | 0.49 | 58.5 | 12.81 | 21.10 | 0.54 | 57.0 | 10.63 | 18.20 | 0.42 |
Across generators, final accuracy changes by at most 0.4 points and RR by at most 2.2 points, while all reduce RR from 78.13–89.06% to 8.75–12.81%. This stability is expected: the accepted cache size leaves unchanged, while the common client-side filter limits distributional mismatch. Generator choice therefore causes only small variation after the same acceptance protocol. We will add this ablation and the exact configurations to the revision.
Thanks for the clarification and addressing my concerns.
Thank you for your time and constructive feedback.
- Rating
- 4/6
- Confidence
- 3/5
- Quality
- 2/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
This paper proposes Aegis, a generative gradient-mixing defense for federated learning. Each client generates synthetic, task-relevant samples, computes an auxiliary gradient from them, and combines it with the private-data gradient. The resulting increase in effective batch size is intended to exceed the capacity of linear-leakage attacks, causing reconstructed samples to collapse into mixtures. The method is evaluated against Robbing-the-Fed, LOKI, and Scale-MIA using PSNR, SSIM, and RR.
Strengths and weaknesses
Strengths
- The method is intuitive, client-side, and compatible with existing federated-learning protocols. The reported experiments show that increasing the synthetic masking batch substantially reduces the reconstruction quality of the evaluated attacks.
Major Weaknesses
-
Lack of comparison with prior gradient-mixing work. For example, Eloul et al., “Mixing Gradients in Neural Networks as a Strategy to Enhance Privacy in Federated Learning,” WACV 2024, also use gradient mixing to mitigate inversion attacks, although their method mixes gradients among samples within a batch rather than combining gradients from private and auxiliary data. The authors should at least (1) include this method as a baseline and (2) cite and clearly discuss how Aegis differs from it.
-
Medical utility is not evaluated. Although the paper is framed around medical federated learning, task accuracy is reported only on MNIST and CIFAR-10, whereas the MedMNIST experiments evaluate privacy alone. The authors should report downstream task accuracy on the medical datasets to substantiate the claim that Aegis preserves utility in clinical applications.
-
Lack of generator analysis. The method relies heavily on masking gradients computed from Stable Diffusion-generated samples. However, the paper does not clearly state was fine-tuned on medical data and, if so, what data were used. Also, how realistic and diverse the generated medical images are. Since the quality and distributional alignment of the synthetic data may directly affect both privacy and utility, these aspects should be evaluated more thoroughly.
-
No privacy–utility trade-off analysis. The authors vary the masking batch size and report improved privacy, but do not provide the corresponding task accuracy across all datasets. Since the synthetic gradient could substantially degrade the accuracy, the paper should report privacy–utility trade-off curves for Aegis and all evaluated baselines.
Minor Issues
-
SSIM range. At Line 257, the SSIM range should be stated consistently with the implementation. In standard image-evaluation settings, SSIM is commonly reported in the range [0,1], rather than [−1,1].
-
Unclear gradient weighting. The update equation around Line 217 should clarify how the private and synthetic gradients are weighted. The equation applies the same learning rate to both gradients, whereas the subsequent discussion describes a weighted mixture.
-
Wall-clock comparison. Figure 3 should also plot accuracy against wall-clock time. Communication rounds alone do not provide a fair efficiency comparison because the evaluated defenses have substantially different per-round computational costs, as shown in Table 1.
-
At Line 259, the authors should define the abbreviation as “reconstruction rate (RR),” since RR is used later without a clear prior definition.
Questions
Please address the major concerns raised above, particularly the following:
-
How does Aegis differ from prior gradient-mixing methods, especially Eloul et al. (WACV 2024), and why is this closely related work neither discussed nor included as a baseline?
-
Why is task accuracy not reported on the medical datasets, despite the paper being primarily motivated by medical federated learning?
-
How was the generator configured and evaluated for the medical datasets? In particular, was it fine-tuned on medical data, what data were used, and how were the realism, diversity, and distributional alignment of the generated samples assessed?
-
Why are privacy–utility trade-off curves not provided for Aegis and the evaluated baselines across different defense strengths?
Limitations
No. The authors do not evaluate the trade-off between privacy and task utility, especially on the medical datasets.
Final justification
The authors provided useful additional results so I decided to raise score to borderline accept.
Formatting concerns
no
3 comments
We thank the reviewer for the constructive comments.
1. Lack of comparison with previous gradient-mixing work
We completely agree and thank the reviewer for identifying Eloul et al.; we will cite and discuss this important precursor. As the reviewer notes, both works share the philosophy that gradient mixing reduces reconstruction: Eloul et al. mix private-sample gradients through the local training strategy, whereas Aegis adds an auxiliary-data gradient. The distinction is the attack regime and enforcement mechanism. Eloul et al. evaluate conventional optimization-based MIAs, while Table A.2 shows that utility-preserving changes to local training settings do not stop the state-of-the-art linear-leakage attack Robbing-the-Fed (SSIM remains 0.99 across batch sizes 32–128). Aegis explicitly adds task-relevant synthetic contributions so that the private plus defense batch exceeds the leakage bins, protecting against both attack families. We also evaluate their strongest configuration (MSE with same-label batching) under our unchanged FL and Robbing-the-Fed protocol. It preserves utility but only marginally reduces reconstruction because it does not enforce . We will add this direct baseline and make the connection explicit.
2. Medical utility is not evaluated
We now report final accuracy under the same 100-client non-IID FedAvg setting. Aegis closely matches no defense, while perturbation/pruning defenses incur larger losses.
Table 1. Final medical test accuracy (%)
| Defense | Chest | OrganA | Path |
|---|---|---|---|
| None | 55.8 | 58.6 | 57.3 |
| Eloul et al. | 55.7 | 58.5 | 57.2 |
| Aegis | 55.5 | 58.8 | 57.2 |
| Soteria | 53.8 | 56.6 | 55.3 |
| GC | 51.9 | 54.7 | 53.4 |
| GD | 47.2 | 50.0 | 48.7 |
| Outpost | 49.0 | 51.8 | 50.5 |
| DP | 44.7 | 47.5 | 46.2 |
We will include the corresponding round-to-accuracy curves in the revision.
3. Lack of generator analysis
The reported pipeline is identical across MNIST, CIFAR-10, and the three MedMNIST modalities: public Stable Diffusion 2.0 with OpenCLIP ViT-H/14. Each client uses only locally visible labels for class-aligned prompts, resizes/crops candidates to the target tensor layout, and applies an in-distribution filter estimated from a small held-out slice of its training partition. The public checkpoint is used without dataset-specific fine-tuning; no separate medical generator or test image is used. All artifacts remain local. Optional adaptation on a sanctioned in-domain corpus is supported but unused here.
4. No privacy–utility trade-off analysis
The manuscript reports the medical RR/PSNR/SSIM endpoints without defense and at . We add the Eloul et al. baseline, the masking-batch sweep, and final task accuracy below. ACC and RR are percentages.
Table 2. Privacy–utility trade-off against Robbing-the-Fed
| Setting | Chest ACC↑ | Chest RR↓ | Chest PSNR↓ | Chest SSIM↓ | OrganA ACC↑ | OrganA RR↓ | OrganA PSNR↓ | OrganA SSIM↓ | Path ACC↑ | Path RR↓ | Path PSNR↓ | Path SSIM↓ |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| None | 55.8 | 89.06 | 62.40 | 0.94 | 58.6 | 82.81 | 50.60 | 0.89 | 57.3 | 78.13 | 45.20 | 0.86 |
| Eloul et al. | 55.7 | 85.94 | 58.90 | 0.92 | 58.5 | 79.69 | 47.90 | 0.87 | 57.2 | 75.00 | 42.60 | 0.83 |
| Aegis-512 | 56.0 | 49.95 | 34.59 | 0.69 | 58.8 | 47.82 | 31.19 | 0.69 | 57.5 | 44.34 | 27.45 | 0.61 |
| Aegis-1024 | 55.9 | 27.03 | 25.06 | 0.55 | 59.0 | 27.31 | 24.54 | 0.58 | 57.6 | 24.53 | 21.36 | 0.47 |
| Aegis-1536 | 55.7 | 16.24 | 21.08 | 0.49 | 58.9 | 17.66 | 21.76 | 0.53 | 57.4 | 15.21 | 18.82 | 0.41 |
| Aegis-2048 | 55.5 | 9.50 | 18.70 | 0.46 | 58.8 | 11.63 | 20.10 | 0.51 | 57.2 | 9.38 | 17.30 | 0.38 |
Eloul et al. preserves utility but only modestly reduces RR. Consistent with Fig. 4, Aegis reconstruction metrics fall steeply through and then taper, while accuracy remains within a fraction of a point of no defense.
5. Gradient weighting and minor clarifications
No mixing coefficient is tuned. In each epoch, the client completes the real-data mini-batches and then applies one defense update with the same optimizer and learning rate; defense micro-batches are accumulated into that update. The in the effective-gradient view only normalizes this unweighted sequence by sample count; it is not an implementation multiplier. Optional scaling is unused. We will correct the SSIM range to , define RR at first use, and add accuracy-versus-wall-clock curves.
Thank you for the authors’ response. Given the additional results, I have raised my score. However, the baseline comparison, trade-off curve, and medical-dataset accuracy should have been included in the original submission, not rebuttal. If accepted, all rebuttal results and clarifications should be incorporated into the camera-ready version.
Thank you for your constructive feedback. If accepted, we will incorporate all additional results and clarifications into the camera-ready version.
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
We sincerely thank the Area Chair and all reviewers for the constructive comments and the time devoted to evaluating our work. After carefully considering the feedback, we have provided detailed clarifications and conducted additional experiments that address the main concerns:
Technical details. We clarify how the defense batch is selected relative to the attack-bin width k, that k is directly visible from the first crafted fully connected layer in the broadcast model, and that our implementation applies an unweighted defense-gradient update after the real-data mini-batches in each local epoch.
Missing baseline. We add the suggested prior gradient-mixing method as a direct baseline under the same federated-learning and Robbing-the-Fed protocol, and clarify its relationship to and distinction from Aegis.
Generator configuration. We specify the exact reported pipeline—public Stable Diffusion 2.0 with OpenCLIP ViT-H/14, locally visible labels, and client-side in-distribution filtering—and clarify that no test images or dataset-specific generator fine-tuning are used. We also add an ablation using alternative diffusion-, VAE-, and GAN-based generators.
Medical evidence and generalization. We add final task accuracy and privacy–utility results (RR, PSNR, and SSIM) on ChestMNIST, OrganAMNIST, and PathMNIST, together with sensitivity studies over masking-batch size, non-IID partitions, and CNN/Transformer backbones. We also clarify that MedMNIST provides a controlled evaluation across three medical modalities, while validation on full-resolution DICOM studies, 3D volumes, and whole-slide pathology remains an important extension rather than a claim made by the current paper.
We believe these clarifications and additional results substantially address the concerns raised in the reviews and strengthen the technical and empirical case for the paper. We would be very happy to discuss any remaining questions with the Area Chair and reviewers. Thank you again for your careful assessment and valuable feedback.