Neural‑Visual Decoding via Cognitive‑guided Adaptive Blurring and Information‑Constrained Alignment
Fan Yin, Chuhang Zheng, Peiliang Gong, Donghai Guan, Qi Zhu
NeurIPS 2026
TL;DR. We propose CAIA, a pioneering framework that adaptively blurs images and constrains EEG features to significantly improve cross-modal alignment for more robust EEG-based visual decoding.
Abstract. EEG-based visual decoding aims to establish a mapping between neural signals and visual semantics. However, it remains constrained by the dual challenges of severe information granularity mismatch and the low signal-to-noise ratio (SNR) of EEG signals. Existing approaches typically treat visual features as static, ignoring the dynamic selectivity of human vision and the frequency specificity of neural oscillations. To bridge this gap, we propose CAIA, a Cognitive-guided Adaptive blurring with Information-Constrained Alignment framework for Neural-Visual decoding. On the visual side, it simulates selective attention to adaptively reduce redundancy. Meanwhile, on the EEG side, it combines neural oscillation priors with an information-bottleneck-inspired spectral sparsity regularizer to enhance SNR. Specifically, we devise a cognitive-dynamics-based adaptive blurring mechanism that dynamically integrates center-biased and saliency-guided visual cues via cross-modal attention. Furthermore, we introduce a distribution-aware boundary calibration loss to robustly rectify alignment bias caused by outlier samples. Moreover, a cognitively guided information-screening method is proposed to select task-relevant EEG oscillations. Extensive experiments demonstrate that CAIA improves both subject-dependent and subject-independent average Top-1 and Top-5 accuracy in zero-shot brain-to-image retrieval, significantly outperforming prior methods. Our work validates that optimizing visual information density to match neural granularity offers a more interpretable and robust pathway for neural decoding. Code is available at https://github.com/mikumafu/CAIA.
Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.
Claim this paperedit · history
NeurIPS 2026
Accept (spotlight) · 3 reviews · OpenReview
Updated 25 Nov 2026, 03:43 UTC.
- Decision
- Accept (spotlight)
Read decision
Meta-review
All three reviewers recognized that this paper offers a solid and valuable contribution to zero-shot EEG/MEG-to-image retrieval by addressing cross-modal information mismatch through adaptive visual representation simplification and neural frequency screening. During the rebuttal, the authors thoroughly addressed the main concerns regarding statistical robustness, parameter-count confounds, theoretical framing, and module interaction through extensive new controls, including 5-seed statistical tests ( over UBP), a capacity-matched baseline ( parameters; UBP at 51.3% vs. CAIA at 70.3%), and appropriate softening of cognitive claims. In the post-rebuttal discussion, all reviewers expressed high satisfaction with these empirical additions and reframings: Reviewer MRWx explicitly noted that the capacity control and statistical evidence resolved their primary doubts and raised their score, while Reviewers 7EoB and Jzyq similarly acknowledged that the responses successfully addressed their technical concerns and supported an increased score. With all major doubts conclusively resolved and strong empirical validation established across benchmarks, I recommend Acceptance.
Final justification
Taking into account the initial reviews, the comprehensive author response, and the post-rebuttal discussions, I recommend Acceptance for this paper. The core contribution of this work is CAIA, an innovative framework for zero-shot EEG/MEG-to-image retrieval that effectively mitigates cross-modal information mismatch via adaptive visual representation simplification and neural spectral screening. During the rebuttal, the authors decisively resolved all primary technical concerns—particularly regarding parameter confounds and statistical robustness—by providing multi-seed significance tests ( over UBP) and a capacity-matched control experiment (CAIA at 70.3% vs. capacity-matched UBP at 51.3%). Impressed by these rigorous evaluations and appropriate reframings, the reviewers raised their scores and reached a consensus that the reported performance gains are real and statistically sound. The paper establishes a strong, validated benchmark for future brain-decoding research.
Read meta-review
Meta-review
All three reviewers recognized that this paper offers a solid and valuable contribution to zero-shot EEG/MEG-to-image retrieval by addressing cross-modal information mismatch through adaptive visual representation simplification and neural frequency screening. During the rebuttal, the authors thoroughly addressed the main concerns regarding statistical robustness, parameter-count confounds, theoretical framing, and module interaction through extensive new controls, including 5-seed statistical tests ( over UBP), a capacity-matched baseline ( parameters; UBP at 51.3% vs. CAIA at 70.3%), and appropriate softening of cognitive claims. In the post-rebuttal discussion, all reviewers expressed high satisfaction with these empirical additions and reframings: Reviewer MRWx explicitly noted that the capacity control and statistical evidence resolved their primary doubts and raised their score, while Reviewers 7EoB and Jzyq similarly acknowledged that the responses successfully addressed their technical concerns and supported an increased score. With all major doubts conclusively resolved and strong empirical validation established across benchmarks, I recommend Acceptance.
Final justification
Taking into account the initial reviews, the comprehensive author response, and the post-rebuttal discussions, I recommend Acceptance for this paper. The core contribution of this work is CAIA, an innovative framework for zero-shot EEG/MEG-to-image retrieval that effectively mitigates cross-modal information mismatch via adaptive visual representation simplification and neural spectral screening. During the rebuttal, the authors decisively resolved all primary technical concerns—particularly regarding parameter confounds and statistical robustness—by providing multi-seed significance tests ( over UBP) and a capacity-matched control experiment (CAIA at 70.3% vs. capacity-matched UBP at 51.3%). Impressed by these rigorous evaluations and appropriate reframings, the reviewers raised their scores and reached a consensus that the reported performance gains are real and statistically sound. The paper establishes a strong, validated benchmark for future brain-decoding research.
- Rating
- 3/6
- Confidence
- 4/5
- Quality
- 3/4
- Clarity
- 2/4
- Significance
- 2/4
- Originality
- 2/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The authors introduce CAIA, a cognitive-guided framework for EEG/MEG-based visual decoding. The pipeline features EEG-driven cross-modal attention for fusing saliency-guided blurred images, combined with an information-bottleneck-inspired frequency band selection. Utilizing a novel distribution-aware boundary calibration loss, the method is evaluated on the THINGS-EEG and THINGS-MEG datasets, demonstrating its zero-shot image retrieval (200-way).
Strengths and weaknesses
Strengths:
- Combining visual-side information reduction with EEG-side signal screening is intuitive and relevant.
- The method reports strong improvements over several recent EEG visual decoding baselines.
- The ablation study separates the effects of adaptive blurring, frequency screening, and boundary calibration.
- The paper includes both EEG and MEG evaluations, which broadens the empirical scope. Weakness:
- The paper makes strong cognitive and neuroscience claims, but the evidence is mostly retrieval performance rather than direct validation of cognitive mechanisms. The paper lacks sufficient statistical evidence, such as confidence intervals, multiple seeds, and significance tests.
- The reported gains are very large, so the paper needs stronger evidence that they do not come from protocol differences or preprocessing advantages. The comparison with prior methods may not be fully fair unless all baselines share identical preprocessing, channel selection, visual encoders, and evaluation protocols.
- A substantial performance gap remains between the subject-dependent and subject-independent settings, highlighting limited cross-subject robustness. Inconsistent bolding in the performance tables raises concerns regarding the rigor and accuracy of the reported results.
- The evaluation relies on averaged repeated trials, which weakens the claimed relevance to practical real-time BCI.
- The interpretability claims are not fully convincing because the attention and frequency analyses are mostly post-hoc visualizations.
- The method is validated only on retrieval, so it is unclear whether it improves broader neural-visual decoding tasks such as reconstruction or semantic generation.
Questions
see weakness
Limitations
yes
Final justification
The rebuttal has improved my assessment of the paper. I am willing to reconsider its quality and originality and raise my score accordingly.
Formatting concerns
no
3 comments
Thank you for the substantial efforts in addressing my concerns. The response and additional analyses resolve most of my major questions.
Regarding the cognitive and neuroscientific claims, the revised, more cautious wording is scientifically appropriate, although it also weakens part of the paper’s original motivation and central positioning. Regarding generalization and practical applicability, these issues are not empirically resolved, but I consider it reasonable at this stage to clearly acknowledge them as limitations and avoid overclaiming.
Overall, the rebuttal has improved my assessment of the paper. I am willing to reconsider its quality and originality and raise my score accordingly.
We sincerely thank the reviewer for the thoughtful and constructive feedback, and we appreciate the willingness to reconsider the score.
We will carefully revise the manuscript to adopt more cautious wording regarding the cognitive and neuroscientific claims, and we will clearly acknowledge generalizability as a limitation without overclaiming. We will also incorporate all rebuttal-only analyses into the revised manuscript to further strengthen the empirical foundation of the paper.
We thank the reviewer again for the time and expertise in reviewing our work.
- Rating
- 5/6
- Confidence
- 5/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 4/4
- Originality
- 4/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
Zero-shot visual decoding of EEG signals consists in mapping a person's brain signal, recorded while they view an image, to that image's visual content. Given a novel EEG trial, the goal is to identify which image (from a pool the model never saw during training) the person was looking at. This is a difficult task because images and EEG carry information at very different granularities: images contain fine-grained detail while EEG captures a much coarser signal reflecting mixed activity across large cortical populations. In addition EEG’s low signal-to-noise ratio, due to external and internal noise sources (electrical interference, physiological state fluctuations), further impedes alignment. Prior work (the UBP model being the state of the art) addressed the granularity mismatch by blurring images according to a fixed center-bias prior, on the assumption that gaze defaults to image centers and peripheral detail can be safely discarded. However, this approach has two limitations: it does not account for salient peripheral objects that can capture attention, and it does not address EEG's low signal-to-noise ratio problem. The authors propose a new model, CAIA, which address both sides simultaneously: (1) a saliency-guided and a center-biased blurred version of each image are adaptively combined via cross-modal attention, with EEG features as the query and the two blurred image feature maps as key/value, letting the fusion weighting vary trial-to-trial; (2) EEG is decomposed into its five standard frequency bands and recombined via learned weights, with an entropy penalty encouraging concentration on a few task-relevant bands to boost SNR; (3) a calibration loss assumes EEG-image similarity scores are Gaussian-distributed and softly pulls outlier scores back toward the bulk of the distribution, preventing them from biasing the contrastive loss. The authors report substantial gains over UBP, within- and between-subject, on THINGS-EEG and THINGS-MEG.
Strengths and weaknesses
Strenghts
- Adapting the image's information content to EEG's capacity, rather than only trying to enrich EEG features to match a rich visual target, is a new approach compared to past EEG-decoding work, which has focused on extracting more signal from noisy EEG signals.
- The ablation study performed by the authors is thorough. Tables 3 and 10 isolate the three components of the model individually, and pairwise, running sensitivity sweeps on blur strength (Table 7) and on confidence level (Table 8). They further break down these analyses per subject rather than only on average.
- The authors also validate the robustness of their model to specific implementations. They test the sensitivity of the model to different saliency backends (Table 5) and to different frequency-filtering strategies (Table 6).
- The authors made a serious effort for reproducibility, providing a link for their code, all the hyperparameters, the hardware specifications, and a comparison of compute-cost against the baseline (Table 9).
Weaknesses
-
The information-bottleneck connection is not formally established. Eq. 14 approximates I(X;Z) via H(M), the entropy of a 5-way softmax over discrete wavelet-band selection weights. But H(M) is not the entropy of the actual high-dimensional encoder output Z. The authors invoke the identity that for a deterministic encoder, I(X;Z) ≤ H(Z), and then substitute H(M) for H(Z). But H(M) and H(Z) can move in unrelated directions: For example if m = [1,0,0,0,0] then H(M) = 0 (minimal value), but if the selected band's features are high-variance and complex across EEG channels and trials, H(Z) could still be large. Conversely, if m = [0.2, 0.2, 0.2, 0.2, 0.2] then H(M) is at its maximum (log(5)), yet if all five bands are low-variance on a given trial, H(Z) could be small. Thus H(M) does not measure uncertainty in the information content of the resulting representation Z. It rather acts as a sparsity regularizer on attention weights, not a compression regularizer on Z. I think this is a substantially weaker claim than what Eq. 11 promises. I recommend either reframing this as a "frequency-gating regularizer inspired by IB" rather than a direct IB instantiation, or deriving an actual variational bound (in the style of deep VIB) connecting H(M) to I(X;Z).
-
L_bound's induced degradation when used alone. Table 3 shows that disabling all three modules gives 54.5/87.3 (Top-1/Top-5), but enabling L_bound alone gives 52.4/85.7, which is worse than the baseline (when all modules are deactivated). The authors' explanation ("it's an anomaly-identification mechanism, not a correction strategy on its own") is plausible but post-hoc, and it means one of the three main components of the model is harmful in isolation. I think this deserves either a mechanistic account of why this happens or a softened framing of the contribution of this component.
-
The authors do not test the Gaussian assumption underlying L_bound. The entire boundary-loss derivation (Eq. 8–10) depends on the assumption that the similarity scores between EEG and Image embeddings pairs follow a normal distribution. But this is only justified only by visual inspection of Figure 3, whose histogram looks right-skewed with a long left tail rather than clearly Gaussian. A formal normality test (Shapiro-Wilk, QQ-plot) would substantiate this assumption, or the authors should report results under a more flexible assumption (e.g., skew-normal) to show robustness if the Gaussian assumption doesn't hold.
-
The parameter-count confound is not addressed. Table 9 reports 107.69M parameters for CAIA versus 43.72M for UBP (2.46×) and roughly 4× the training-step time, with no parameter-matched baseline to isolate how much of the +19.4% Top-1 gain comes from the proposed mechanisms versus simply added capacity. The actual gap may actually be bigger: the frozen ResNet-50 visual backbone accounts for 38.32M parameters in both models, so the trainable parameter counts are 69.37M for CAIA versus 5.40M for UBP. This is a ~12.8× difference, not 2.46×. A clean control would scale up UBP's brain encoder until its trainable parameter count matches CAIA's ~69M parameters, without adding cross-attention, IBWave, or the boundary loss, and report how much of the gap closes.
-
Claims of generalizability rest on a single RSVP task design. THINGS-EEG and THINGS-MEG share the same image set and RSVP-style paradigm. The center-bias and saliency priors thus depend on the paradigm. The authors acknowledge this in their own limitations paragraph. Howerver no experiment tests a free-viewing or non-RSVP dataset to support generalizability beyond this specific experimental design.
-
The UMAP-based validation (Fig. 9) is weak supporting evidence. The authors assert "striking topological similarity" between the EEG and image latent UMAP projections, but this isn't clearly demonstrable from the figure as presented: axis labels are illegible, and the UMAP configuration (hyperparameters, random seed, initialization) is not described. The figure shows only a single run; without knowing how much these panels would vary against themselves under a different random seed on the same data, there's no baseline against which to judge whether the EEG-vs-image visual similarity reflects alignment or run-to-run UMAP variability. The authors could use a quantitative metric, for example Procrustes distance, to compare against a baseline with no structure. This would substantiate the claim far better than visual inspection of one 2D embedding.
Questions
- On the IB framing: Can you provide a formal bound connecting H(M) to I(X;Z) (e.g., a VIB-style KL term), or will you reframe IBWave as "inspired by" rather than "instantiating" the IB principle? A convincing derivation, or a revised framing acknowledging the looseness, would resolve this concern.
- On the parameter confound: Can you report results for a UBP baseline with capacity matched to CAIA— scaling EEGProject alone to ~69M trainable parameters, with no other CAIA mechanisms added? If this baseline doesn't close most of the gap to CAIA's reported numbers, this would substantially raise my confidence that the proposed mechanisms, not capacity, are responsible, and would raise my score.
- On the Gaussian assumption: Can you report a formal normality test (Shapiro-Wilk or equivalent) on the similarity distribution underlying L_bound, and/or results under a more flexible distributional family if normality doesn't hold? Either confirming the assumption or showing robustness to relaxing it would resolve this.
Limitations
The authors explicitly acknowledge that the center-bias and saliency priors presuppose an experimental paradigm with sustained central fixation, and may degrade under free-viewing conditions (corresponding to Weakness 5 above).
The other limitations have been raised in this review under «Weaknesses ».
Final justification
I thank the authors for their thorough rebuttal, which addresses my main concerns. I am raising my score. I have also read the authors' responses to the other reviewers, which reinforce this.
Resolved
-
Parameter confound (my Question 2, the decisive one). The capacity-matched UBP (~68M trainable parameters) reaching only 51.3/80.2% essentially unchanged from the original 50.9/79.7 and far below CAIA's 70.3/96.1% is the control I asked for. It convincingly shows the gains come from the proposed mechanisms and not from added capacity. Combined with the seed-matched paired tests reported to another reviewer (Top-1 t(9)=7.13, Top-5 t(9)=11.35, both p<0.0001) and the 5-seed confidence intervals, I am now confident the improvement over UBP is both real and statistically significant. Please include both the capacity-matched table and the statistical reporting in the revision, and state trainable (not total) parameter counts.
-
IB framing (my Question 1). Reframing IBWave as an IB-inspired spectral sparsity regularizer resolves my concern. The entropy ablation experiment (67.8/94.2 vs. 70.3/96.1, see Table 6 in reply to reviewer 7EoB vs. paper's Table 1) support that the term is doing real work.
-
Gaussian assumption (my Question 3). The Shapiro-Wilk test formally rejects normality (p=0.001), so the assumption behind L_bound's z-score threshold is, strictly, false. What resolves my concern is the follow-up comparison: the z-score boundary (−0.785, derived assuming Gaussianity) and a distribution-free empirical 2.5th-percentile boundary (−0.777, no distributional assumption) are nearly identical, with >99% overlap in the flagged outlier sets. This shows the outlier-flagging behavior of L_bound does not actually depend on the Gaussian assumption holding, despite the assumption being technically violated. As a minor point, the check compares boundaries computed from some similarity distribution. It would be helpful to specify whether this distribution is pooled across all subjects.
L_bound in isolation (my Weakness 2). My earlier concern was that the synergy account was post-hoc. The added comparison against SupCon (66.7/94.6) and hard-example weighting (64.1/93.0, in reply to reviewer 7EoB section 5), both below full CAIA, gives concrete evidence that L_bound is beneficial as an integrated calibration signal rather than a standalone loss. I find the mechanism proposed by the authors to explain why L_bound can lead to degradation when used alone plausible, and I am satisfied with reframing it as a synergistic component.
- UMAP. Downgrading to a qualitative visualization and adding the Procrustes disparity (0.114 vs. 0.993 random baseline), with hyperparameters and legible axes, is a clear improvement. However, UMAP is stochastic and hyperparameter-sensitive (n_neighbors, min_dist, random seed all change the embedding substantially). A single disparity value of 0.114 from one embedding run doesn't tell you whether that number is stable — rerun with a different seed and it could plausibly shift meaningfully. Without a distribution across seeds (analogous to the 5-seed reporting they did elsewhere), you can't tell if 0.114 is a robust property of the model or an artifact of one UMAP run.
These points are conditional on the promised analyses being incorporated into the manuscript rather than remaining in the rebuttal alone, but none undermine the core finding: the capacity-matched control and the seed-matched significance tests establish that CAIA's gains over UBP are real and not attributable to added capacity. I would also ask the authors to:
- Gaussian assumption: clarify whether the Shapiro-Wilk/boundary-comparison check was computed on data pooled across subjects, or per-subject; a per-subject breakdown would strengthen it (but is not mandatory).
- UMAP: report Procrustes disparity across multiple seeds (not a single run), given UMAP's sensitivity to random seed and hyperparameters (n_neighbors, min_dist) — otherwise it's unclear whether 0.114 is a stable property of the model or an artifact of one embedding.
- every rebuttal-only analysis (capacity-matched control, entropy ablation, Gaussian diagnostics, SupCon/hard-example comparisons, Procrustes check) needs to actually appear in the revised manuscript, not remain only in the rebuttal thread.
Formatting concerns
I did not find any ethical concern. The paper does not present any newly collected human-subjects data.
3 comments
Rebuttal
We sincerely thank the reviewer for the positive and constructive evaluation. We are grateful that the reviewer recognized the novelty and empirical value of CAIA, as well as the thorough ablation and reproducibility efforts. We address the reviewer’s concerns on the IB framing, boundary loss, Gaussian assumption, parameter confound, generalizability, and UMAP analysis below.
1. On the IB Framing
We agree with the reviewer that H(M) should not be presented as a formal approximation to H(Z), and that our current wording may overstate the connection to the information bottleneck principle. In the revision, we will reframe IBWave as an IB-inspired frequency sparsity regularizer rather than a formal VIB-style objective.
Concretely, H(M) regularizes the entropy of the learned band-selection distribution, encouraging the model to concentrate on a smaller set of task-relevant frequency bands. This provides a practical capacity-control mechanism over the spectral input to the EEG encoder, but it is not a tight bound on I(X;Z). We will revise the method section accordingly and avoid claiming that H(M) directly estimates or bounds H(Z).
Empirically, the entropy term is not inert: when we retain learnable frequency-band scaling but remove the entropy regularizer, performance drops from 70.3%/96.1% to 67.8%/94.2%. This supports the role of the entropy term as a useful spectral sparsity constraint, while we will present it as IB-inspired rather than a formal information-bottleneck instantiation.
2. On the Boundary Calibration Loss
We agree that L_bound should be presented as a synergistic component rather than an independently beneficial loss. When used alone, L_bound flags low-similarity or outlier EEG-image pairs but the model lacks an adaptive mechanism to correct the underlying mismatch. In this setting, the additional penalty can introduce noisy gradients and interfere with the contrastive objective, leading to the observed degradation. When combined with IBWave and attention, however, the model has mechanisms to respond to the calibration signal: IBWave can adjust the spectral emphasis of noisy EEG inputs, while the attention module can adapt the visual fusion path. This explains why L_bound is harmful in isolation but beneficial in the full CAIA design.
3. On the Gaussian assumption
We agree that the normality assumption underlying L_bound warrants empirical verification. To this end, we examined the matched-pair similarity distribution using both formal tests and diagnostic plots. The Shapiro-Wilk test yields p = 0.001, which clearly rejects strict normality; however, the Q-Q plot shows a strong linear correlation (R² = 0.978), suggesting that the central mass of the distribution aligns well with a normal reference, with deviations primarily confined to the tails. Because L_bound is designed to operate on low-similarity pairs, which are likely to reflect noisy or poorly aligned EEG-image samples, we compared its z-score-based lower boundary against a non-parametric 2.5th percentile threshold. The two boundaries (−0.785 vs. −0.777) are nearly identical, and their flagged sample sets overlap by over 99%. This robustness check confirms that the outlier detection mechanism is not materially affected by modest departures from normality, and that replacing the z-score criterion with a percentile-based one would yield essentially the same samples and loss behavior.
4. On the parameter confound
We agree that parameter count is an important confound to control. To test whether the gain comes mainly from model capacity, we scaled the UBP EEGProjectLayer to approximately 68M trainable parameters, without adding any CAIA components. The capacity-matched UBP obtains 51.3%/80.2%, only slightly outperforms the original UBP result of 50.9%/79.7 and still far below CAIA’s 70.3%/96.1%. This indicates that simply increasing the baseline encoder capacity does not explain CAIA’s gain. We will include this capacity-matched control in the revised appendix.
Table1: Capacity-matched UBP results (68M).
| UBP (68M) | sub-01 | sub-02 | sub-03 | sub-04 | sub-05 | sub-06 | sub-07 | sub-08 | sub-09 | sub-10 | Mean |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Top-1 | 44.0 | 51.5 | 51.5 | 49.5 | 44.5 | 58.0 | 49.0 | 58.5 | 46.0 | 61.0 | 51.3 |
| Top-5 | 72.5 | 81.5 | 83.0 | 76.5 | 74.5 | 83.5 | 80.0 | 85.5 | 77.5 | 87.5 | 80.2 |
5. On Generalizability Beyond the RSVP Paradigm
We agree that the current evidence is based on THINGS-EEG and THINGS-MEG, which share an RSVP-style stimulus paradigm and the THINGS image set. We will therefore avoid making broad claims that CAIA has been validated across arbitrary viewing conditions or task designs. Instead, we will state that CAIA is validated under zero-shot retrieval settings with centrally controlled RSVP-style neuroimaging protocols.
We will also expand the limitations section to note that center-bias and saliency priors may behave differently under free viewing, active search, or paradigms with eye movements. Testing CAIA under those settings is an important direction for future work.
6. On the UMAP
We agree that the UMAP visualization should not be used as strong evidence for cross-modal alignment. The phrase “striking topological similarity” was overstated, and we will revise it to present UMAP only as a qualitative visualization. As an additional diagnostic, we computed Procrustes disparity between matched EEG-image UMAP coordinates, obtaining 0.114 compared with 0.993 for a random/no-structure baseline. We will report this only as a supporting descriptive measure, together with UMAP hyperparameters and clearer axis labels, rather than as central evidence for the method.
Thank you again for your insightful and thorough feedback.
Capacity control and statistical evidence resolve my main concerns — score confidence raised
I thank the authors for their thorough rebuttal, which addresses my main concerns. I am raising my score. I have also read the authors' responses to the other reviewers, which reinforce this.
Resolved
-
Parameter confound (my Question 2, the decisive one). The capacity-matched UBP (~68M trainable parameters) reaching only 51.3/80.2% essentially unchanged from the original 50.9/79.7 and far below CAIA's 70.3/96.1% is the control I asked for. It convincingly shows the gains come from the proposed mechanisms and not from added capacity. Combined with the seed-matched paired tests reported to another reviewer (Top-1 t(9)=7.13, Top-5 t(9)=11.35, both p<0.0001) and the 5-seed confidence intervals, I am now confident the improvement over UBP is both real and statistically significant. Please include both the capacity-matched table and the statistical reporting in the revision, and state trainable (not total) parameter counts.
-
IB framing (my Question 1). Reframing IBWave as an IB-inspired spectral sparsity regularizer resolves my concern. The entropy ablation experiment (67.8/94.2 vs. 70.3/96.1, see Table 6 in reply to reviewer 7EoB vs. paper's Table 1) support that the term is doing real work.
-
Gaussian assumption (my Question 3). The Shapiro-Wilk test formally rejects normality (p=0.001), so the assumption behind L_bound's z-score threshold is, strictly, false. What resolves my concern is the follow-up comparison: the z-score boundary (−0.785, derived assuming Gaussianity) and a distribution-free empirical 2.5th-percentile boundary (−0.777, no distributional assumption) are nearly identical, with >99% overlap in the flagged outlier sets. This shows the outlier-flagging behavior of L_bound does not actually depend on the Gaussian assumption holding, despite the assumption being technically violated. As a minor point, the check compares boundaries computed from some similarity distribution. It would be helpful to specify whether this distribution is pooled across all subjects.
L_bound in isolation (my Weakness 2). My earlier concern was that the synergy account was post-hoc. The added comparison against SupCon (66.7/94.6) and hard-example weighting (64.1/93.0, in reply to reviewer 7EoB section 5), both below full CAIA, gives concrete evidence that L_bound is beneficial as an integrated calibration signal rather than a standalone loss. I find the mechanism proposed by the authors to explain why L_bound can lead to degradation when used alone plausible, and I am satisfied with reframing it as a synergistic component.
- UMAP. Downgrading to a qualitative visualization and adding the Procrustes disparity (0.114 vs. 0.993 random baseline), with hyperparameters and legible axes, is a clear improvement. However, UMAP is stochastic and hyperparameter-sensitive (n_neighbors, min_dist, random seed all change the embedding substantially). A single disparity value of 0.114 from one embedding run doesn't tell you whether that number is stable — rerun with a different seed and it could plausibly shift meaningfully. Without a distribution across seeds (analogous to the 5-seed reporting they did elsewhere), you can't tell if 0.114 is a robust property of the model or an artifact of one UMAP run.
These points are conditional on the promised analyses being incorporated into the manuscript rather than remaining in the rebuttal alone, but none undermine the core finding: the capacity-matched control and the seed-matched significance tests establish that CAIA's gains over UBP are real and not attributable to added capacity. I would also ask the authors to:
- Gaussian assumption: clarify whether the Shapiro-Wilk/boundary-comparison check was computed on data pooled across subjects, or per-subject; a per-subject breakdown would strengthen it (but is not mandatory).
- UMAP: report Procrustes disparity across multiple seeds (not a single run), given UMAP's sensitivity to random seed and hyperparameters (n_neighbors, min_dist) — otherwise it's unclear whether 0.114 is a stable property of the model or an artifact of one embedding.
- every rebuttal-only analysis (capacity-matched control, entropy ablation, Gaussian diagnostics, SupCon/hard-example comparisons, Procrustes check) needs to actually appear in the revised manuscript, not remain only in the rebuttal thread.
We sincerely thank the reviewer for the positive and constructive additional comments, and we are grateful that the reviewer expressed confidence in our rebuttal and indicated a willingness to raise the score.
1. On the Gaussian assumption.
We thank the reviewer for this helpful suggestion. In the initial rebuttal, the Shapiro-Wilk, Q-Q, and boundary-overlap diagnostics were reported for subject 8 as a representative case. To further check whether the conclusion holds at the individual-subject level, we repeated the same analysis for all 10 subjects.
The per-subject Shapiro-Wilk results are mixed: three subjects (03, 06, 09) do not reject normality at the 5% level, whereas the remaining subjects reject strict normality. The results demonstrate that strict Gaussianity should not be treated as a required assumption for L_bound. More importantly, Q-Q R2 exceeds 0.96 for every subject, and the z-score lower-boundary criterion remains highly consistent with the empirical 2.5th-percentile criterion across subjects.
Specifically, the lower-boundary overlap is above 92% for all subjects, above 95% for eight subjects, and close to or above 98% for six subjects. These results indicate that L_bound's practical outlier-flagging behavior is robust across subjects and is not specific to the representative subject reported in our initial rebuttal. We will include this per-subject diagnostic table in the revised manuscript.
Table 1: Per-subject Gaussian diagnostics
| Subject | sub-01 | sub-02 | sub-03 | sub-04 | sub-05 | sub-06 | sub-07 | sub-08 | sub-09 | sub-10 |
|---|---|---|---|---|---|---|---|---|---|---|
| Shapiro-Wilk p | 0.0001 | 0.0007 | 0.7582 | 0.0054 | 0.0229 | 0.2535 | 0.0120 | 0.0010 | 0.1762 | 0.0003 |
| Q-Q R² | 0.964 | 0.977 | 0.996 | 0.983 | 0.985 | 0.992 | 0.983 | 0.978 | 0.993 | 0.972 |
| Lower overlap | 98.1% | 95.2% | 99.6% | 92.2% | 99.6% | 99.7% | 95.6% | 99.5% | 98.0% | 94.9% |
2. On the UMAP
We agree that a single UMAP run is insufficient because UMAP is stochastic and sensitive to random seed. We therefore repeated the Procrustes analysis under five UMAP random seeds using the reported parameters (n_neighbors = 15, min_dist = 0.1). The matched-pair disparity remains stable, with mean = 0.115 and range = 0.108-0.121, whereas the random baseline remains around 0.993. This suggests that the reported disparity is not an artifact of a single UMAP seed. We will nevertheless present UMAP as a qualitative visualization with this stability check as a supplementary diagnostic, not as central evidence for CAIA's performance.
Table 2: Procrustes disparity of UMAP embeddings (5 seeds)
| UMAP seed | 0 | 1 | 2 | 3 | 4 |
|---|---|---|---|---|---|
| Matched pair | 0.114 | 0.119 | 0.108 | 0.121 | 0.111 |
| Random baseline | 0.993 | 0.993 | 0.994 | 0.992 | 0.993 |
All rebuttal-only analyses will be incorporated into the revised manuscript. Thank you again for your insightful and thorough feedback.
- Rating
- 4/6
- Confidence
- 2/5
- Quality
- 3/4
- Clarity
- 3/4
- Significance
- 3/4
- Originality
- 3/4
- Contribution type
- general
- Ethical concerns
- NO or VERY MINOR ethics concerns only
Read review
Summary
The paper proposes CAIA, a framework for zero-shot brain-to-image retrieval from EEG/MEG recordings. The method tries to reduce the mismatch between detailed visual features and lower-SNR neural signals through three components: an EEG-conditioned fusion of center-biased and saliency-guided blurred images, an information-bottleneck-inspired frequency screening module for neural signals, and a distribution-aware boundary calibration loss for EEG-image contrastive alignment. The paper evaluates CAIA on THINGS-EEG and THINGS-MEG under subject-dependent and subject-independent protocols, reporting large gains over several prior methods, especially UBP, and provides ablations for the main modules.
Strengths and weaknesses
This is a strong empirical submission in an interesting and difficult area: EEG-based visual decoding with zero-shot image retrieval. The central design choice is sensible: rather than only increasing EEG encoder capacity, the method tries to make the visual representation less overly detailed and the EEG representation less noisy before CLIP-space alignment. The reported numbers are impressive. On THINGS-EEG subject-dependent retrieval, the average Top-1/Top-5 improves from 50.9/79.7 for UBP to 70.3/96.1. The paper also reports gains in subject-independent EEG and in THINGS-MEG. The ablation table is useful: ATTN and IBWave each improve the base model, and the full model performs best. The image-fusion comparison supports the value of EEG-conditioned center/saliency fusion over several fixed alternatives, and the static-filter comparison suggests that learnable frequency screening is more effective than simple high-, low-, or mid-frequency filtering.
The main quality concern is that the empirical evidence is much stronger for benchmark performance than for the causal or neuroscientific interpretation. The paper does not report random-seed repeats, confidence intervals, paired statistical tests across subjects, or enough detail about baseline reimplementation and hyperparameter budgets. Given the unusually large gains over several methods, these controls are important. I also found the attribution of some gains under-explained. For example, the boundary loss alone is worse than the base model, so it should be presented as a synergistic calibration term rather than an independently helpful component. The Gaussian similarity assumption and batch-level outlier definition are plausible but not stress-tested across subjects, batches, or training phases.
The neuroscience framing is appealing but sometimes stronger than the evidence. Center bias, saliency capture, beta-band oscillations, and information bottleneck principles are reasonable priors for motivating the architecture. However, the paper does not include eye tracking, fixation measures, behavioral attention indicators, or causal frequency-band manipulations. Therefore, the attention drift and selective-attention claims are mainly indirect inferences from performance and model-generated heatmaps. Similarly, learned beta-band weights are consistent with prior literature, but they do not by themselves establish a mechanistic role for beta oscillations in this dataset.
The clarity is generally good: the method components, datasets, and main experimental protocol are readable, and the appendix includes helpful additional ablations. The paper would be clearer if it separated engineering evidence from cognitive/neural interpretation more carefully. In particular, "IB" should be described as an IB-inspired regularizer or frequency-selection surrogate unless the authors can justify the mutual-information approximations more rigorously. The claims about real-time BCI relevance should also be qualified because the main EEG protocol uses repeated-trial averaging and a short post-stimulus window, not single-trial online decoding.
In terms of originality, the paper combines several known ingredients--CLIP alignment, center-biased blur priors, saliency, robust contrastive learning ideas, neural frequency priors, and IB-style compression--in a coherent framework. The most original part is the EEG-conditioned fusion of center and saliency blur paths, together with a learnable frequency screening module placed inside the alignment objective. Still, the contribution is more of a well-motivated and effective combination/extension than a fundamentally new learning principle or a direct neuroscience discovery.
Overall, I lean borderline accept because the empirical gains and module-level ablations are strong enough to be valuable, but I would need stronger statistical reporting, baseline fairness checks, and more careful limitation of the cognitive/neural claims to move to a clear accept.
Questions
-
Can you provide statistical uncertainty for the main results: repeated runs with different seeds, confidence intervals or standard errors, and paired tests across subjects? My score would increase if the large gains over UBP and other baselines remain significant under matched runs and subject-level tests.
-
Please clarify baseline fairness. Were all baselines run with the same OpenCLIP encoder, same EEG preprocessing, same repeated-trial averaging, same 0-250 ms window, same channel subset, and comparable hyperparameter-search budget? My score would decrease if the reported gains depend substantially on implementation or preprocessing differences.
-
Can you provide stronger evidence for the attention interpretation? Eye tracking may not be available, but even a controlled analysis on stimuli with off-center salient targets, saliency-backend robustness, or a counterfactual test that breaks the EEG-image pairing for the fusion weights would help. Without such evidence, please soften claims that the module models real attention drift.
-
Can you test the stability and specificity of IBWave? For example, report learned band boundaries/weights across seeds and subjects, compare against a matched learnable filterbank without the IB entropy term, and avoid interpreting beta-band weights as causal neural evidence unless supported by additional analyses.
-
Can you further validate the boundary calibration loss? Please report whether the matched-pair similarity distribution is approximately Gaussian across subjects/training phases, compare against a standard robust contrastive loss or hard-example weighting baseline, and clarify why Lbound alone lowers performance while the full model improves.
Limitations
Partially. The paper acknowledges that center bias and saliency priors depend on sustained central fixation and may degrade under free-viewing conditions. However, the limitations section should be expanded. Important missing limitations include: no direct eye-tracking or behavioral attention evidence; reliance on repeated-trial averaging, which limits claims about real-time single-trial BCI use; lack of statistical uncertainty and repeated-run reporting; limited validation of the Gaussian/outlier assumption in the boundary loss; and the risk of over-interpreting learned frequency weights as neural mechanisms.
Formatting concerns
none
1 comment
Rebuttal
We sincerely thank the reviewer for the positive and constructive evaluation. We are grateful that the reviewer recognized CAIA’s empirical strength, motivation, and ablation evidence. We address the reviewer’s concerns on statistical robustness, baseline fairness, attention interpretation, IBWave stability, boundary-loss validation, and limitations below.
1. On the Statistical Robustness of the Reported Gains
Across five seeds, the mean Top-1 accuracy is 69.66% with SE = 1.03, yielding a 95% CI of [66.79, 72.53]. The mean Top-5 accuracy is 95.80% with SD = 0.59 and SE = 0.26, yielding a 95% CI of [95.07, 96.53]. We additionally performed a seed-matched paired comparison against UBP across the 10 subjects at seed 4. CAIA outperforms UBP by 21.40 Top-1 points and 17.60 Top-5 points, with paired t-tests giving t(9)=7.13, p<0.0001 for Top-1 and t(9)=11.35, p<0.0001 for Top-5. We will report these statistics in the revised experiments section.
Table1: CAIA performance across 5 seeds.
| Seed | CAIA | sub-01 | sub-02 | sub-03 | sub-04 | sub-05 | sub-06 | sub-07 | sub-08 | sub-09 | sub-10 | Mean |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0 | Top-1 | 74.0 | 80.0 | 69.0 | 51.0 | 67.5 | 67.5 | 63.0 | 83.0 | 69.0 | 79.0 | 70.30 |
| 0 | Top-5 | 98.0 | 97.5 | 94.0 | 92.5 | 94.0 | 96.5 | 95.5 | 99.0 | 96.5 | 97.5 | 96.10 |
| 1 | Top-1 | 72.5 | 78.0 | 66.0 | 48.5 | 64.5 | 65.0 | 61.0 | 80.0 | 67.5 | 76.5 | 67.95 |
| 1 | Top-5 | 97.5 | 97.0 | 93.5 | 91.5 | 93.0 | 95.5 | 94.5 | 98.0 | 96.0 | 96.5 | 95.30 |
| 2 | Top-1 | 75.5 | 83.0 | 70.5 | 54.5 | 68.0 | 66.5 | 66.0 | 85.5 | 71.0 | 82.0 | 72.30 |
| 2 | Top-5 | 98.0 | 98.0 | 94.5 | 93.0 | 94.5 | 96.0 | 96.0 | 99.0 | 97.0 | 98.0 | 96.40 |
| 3 | Top-1 | 70.0 | 77.0 | 65.0 | 47.0 | 62.5 | 64.5 | 60.0 | 80.0 | 65.5 | 75.0 | 66.65 |
| 3 | Top-5 | 97.0 | 96.5 | 93.0 | 91.0 | 92.5 | 95.0 | 94.0 | 98.0 | 95.5 | 96.0 | 95.05 |
| 4 | Top-1 | 73.0 | 81.5 | 68.0 | 52.0 | 70.0 | 65.5 | 64.5 | 84.0 | 72.0 | 80.5 | 71.10 |
| 4 | Top-5 | 97.5 | 98.0 | 94.0 | 92.5 | 95.0 | 96.0 | 95.5 | 98.5 | 97.0 | 97.5 | 96.15 |
Table2: UBP results for paired comparison.
| UBP (seed = 4) | sub-01 | sub-02 | sub-03 | sub-04 | sub-05 | sub-06 | sub-07 | sub-08 | sub-09 | sub-10 | Mean |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Top-1 | 42.0 | 49.5 | 49.5 | 48.5 | 42.5 | 56.0 | 48.0 | 56.5 | 44.5 | 60.0 | 49.70 |
| Top-5 | 70.5 | 79.5 | 81.0 | 75.5 | 72.5 | 82.0 | 78.5 | 84.0 | 75.5 | 86.5 | 78.55 |
Table3: Paired t-test results.
| Paired Test | Mean | SD | SE | t | p-value |
|---|---|---|---|---|---|
| Top-1 | 21.40 | 9.50 | 3.00 | 7.13 | < 0.0001 |
| Top-5 | 17.60 | 4.90 | 1.55 | 11.35 | < 0.0001 |
2. On the Fairness of Baseline Comparisons
All baselines were evaluated on the same released THINGS-EEG/MEG .pt files, using the same 250 Hz whitened preprocessing, 0-250 ms post-stimulus window, 17 posterior EEG channels, repeated-trial averaging protocol, 200-way retrieval setting, and OpenCLIP ResNet-50 visual encoder. For method-specific hyperparameters, we followed the original configurations when compatible with this protocol and tuned CAIA using the same validation procedure. We will make these protocol-matching details explicit in the revised manuscript to avoid ambiguity about preprocessing or encoder advantages. Given the fairness of baseline comparisons and the large performance improvement over UBP, the gains are attributable to the proposed components rather than differences in hyperparameter choices.
3. On the Evidence for Attention-Guided Fusion
As the dataset does not include eye-tracking or behavioral attention labels, we agree that the attention interpretation should be tested through controlled perturbations rather than only heatmaps. We therefore adopt a computational counterfactual approach: for each sample, only the CrossModalAttention module receives EEG from a different, randomly selected sample within the batch, while all other components operate on their original inputs. The spatial correlation between attention maps under correctly paired vs. shuffled EEG is 0.0057, indicating no meaningful spatial correspondence; visual inspection confirms that shuffled heatmaps lack discernible structure. Retrieval under shuffled EEG (10 subjects, intra-subject, 200-way) yields mean Top-1/Top-5 of 64.5%/92.0% , supporting the EEG-driven nature of the attention module.
Table4: Shuffled EEG retrieval results.
| shuffled EEG | sub-01 | sub-02 | sub-03 | sub-04 | sub-05 | sub-06 | sub-07 | sub-08 | sub-09 | sub-10 | Mean |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Top-1 | 66.5 | 68.0 | 63.5 | 50.0 | 63.0 | 68.0 | 60.0 | 75.0 | 60.5 | 70.0 | 64.5 |
| Top-5 | 94.5 | 94.0 | 91.0 | 84.0 | 88.0 | 94.5 | 92.0 | 97.0 | 91.0 | 94.0 | 92.0 |
4. On the Stability and Specificity of IBWave
Learned frequency-band weights are stable across both seeds and subjects, with within‑subject cross‑seed variation ≤ 0.005 for all bands, and between‑subject variation substantially larger (β‑band max gap 0.038), as expected given individual differences in EEG frequency profiles.
To isolate the entropy regularizer, we retained the learnable frequency-band scaling but removed the entropy term. This variant achieves 67.8/94.2, lower than the full model's 70.3/96.1, this represents a meaningful 2.5-point decline, confirming that the entropy term is not inert and contributes measurably to performance.
We acknowledge the reviewer's concern regarding causal interpretation of β-band weights. We will revise the manuscript to state that the learned β preference is consistent with prior literature on visual processing, rather than claiming it as mechanistic evidence for β oscillations.
Table5: Learned frequency-band weights across subjects and seeds.
| Band | δ (delta) | θ (theta) | α (alpha) | β (beta) | γ (gamma) |
|---|---|---|---|---|---|
| Range (min~max) | 0.126–0.152 | 0.133–0.161 | 0.218–0.248 | 0.302–0.340 | 0.144–0.163 |
Table6: Results without IB entropy term.
| No-IB | sub-01 | sub-02 | sub-03 | sub-04 | sub-05 | sub-06 | sub-07 | sub-08 | sub-09 | sub-10 | Mean |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Top-1 | 71.0 | 75.0 | 68.5 | 56.5 | 60.5 | 68.0 | 63.0 | 74.5 | 65.5 | 75.0 | 67.8 |
| Top-5 | 95.0 | 96.0 | 94.0 | 91.5 | 90.5 | 95.0 | 92.5 | 96.5 | 94.0 | 97.0 | 94.2 |
5. On the Boundary Calibration Loss
We agree that the distributional assumption behind L_bound should be empirically validated. We conducted formal and diagnostic checks on the matched-pair similarity distribution. Shapiro-Wilk gives p = 0.001, rejecting strict normality, while the Q-Q plot correlation remains high (R2 = 0.978), indicating that the bulk of the distribution is close to a normal reference with deviations mainly in the tails.
Since L_bound mainly targets low-similarity matched pairs that may correspond to noisy or weakly aligned EEG-image samples, we further compared the z-score lower boundary with a non-parametric percentile threshold. The z-score lower boundary (-0.785) is nearly identical to the empirical 2.5th percentile (-0.777), and the two criteria produce more than 99% overlap in flagged samples. This suggests that the outlier-identification behavior is robust to modest deviations from normality.
We also compared L_bound with simpler robust alternatives. SupCon achieves 66.7%/94.6%, and hard-example weighting achieves 64.1%/93.0%, both below the full CAIA result of 70.3%/96.1%. These results indicate that L_bound is most effective as a calibration signal when combined with IBWave and attention, rather than as a standalone loss. We will revise the manuscript to report these diagnostics and to describe L_bound as a synergistic boundary-calibration component instead of an independently beneficial module.
6. On Limitations
The lack of eye-tracking data and the reliance on repeated-trial averaging are inherent to the THINGS-EEG dataset and protocol. We will expand the limitations section to explicitly note these constraints, and we acknowledge that the use of averaged trials limits claims about real-time single-trial BCI applicability.
Thank you again for your thoughtful and constructive feedback.
Comments on the paper
1 comment
Dear Area Chair,
Thank you for handling our submission.
During the rebuttal period, we have addressed the following main concerns:
-
Statistical robustness and baseline fairness: Provided 5‑seed results with 95% confidence intervals and paired t‑tests confirming significant gains over UBP (p < 0.0001). We also confirmed that all baselines share identical preprocessing, visual encoder, and evaluation protocol.
-
Parameter‑count confound: A capacity‑matched UBP (~68M trainable parameters) reached only 51.3% Top‑1 accuracy, far below CAIA’s 70.3%, confirming that the gains arise from the proposed mechanisms rather than from added capacity.
-
IBWave formalization: Reframed IBWave as an IB‑inspired spectral sparsity regularizer rather than a formal information‑bottleneck instantiation, and provided an ablation showing that the entropy term contributes measurably to performance (67.8% vs. 70.3% Top‑1).
-
Boundary calibration loss: Validated that the outlier‑flagging behavior of L_bound is robust to non‑normality via Shapiro–Wilk, Q–Q, and percentile‑comparison diagnostics. We also clarified its synergistic role through comparisons with SupCon and hard‑example weighting.
-
Cognitive and neuroscientific interpretation: Strengthened the attention analysis with an EEG‑shuffling counterfactual showing that retrieval performance drops and attention maps lose structure when the EEG–image pairing is broken. At the same time, we will soften unsupported mechanistic claims (e.g., regarding beta oscillations or selective attention).
We will incorporate all analysis, including the additional analysis presented in the rebuttal, into the revised manuscript.
Thank you for your consideration.
Sincerely,
The Authors
From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.
Loading the discussion…
Rebuttal
We thank the reviewer for the careful evaluation and for recognizing the relevance of combining visual-side information reduction with EEG-side signal screening, the strong improvements over recent baselines, the ablation study, and the EEG/MEG evaluation. We address the concerns on cognitive/neuroscientific claims, baseline fairness, statistical robustness, cross-subject generalization, repeated-trial averaging, interpretability, and retrieval-only evaluation below.
1. On Cognitive and Neuroscientific Claims
We agree that the current evidence is stronger for retrieval performance than for direct cognitive or neuroscientific validation. In the revision, we will calibrate the wording throughout the manuscript. Specifically, we will replace stronger claims such as direct validation of selective attention or beta-band mechanisms with more precise language: the attention module provides EEG-dependent computational evidence for adaptive fusion, and the learned frequency weights are consistent with prior visual-attention literature rather than causal evidence for beta oscillations.
We will also revise the abstract, method analysis, and conclusion to present CAIA primarily as an effective neural-visual retrieval framework inspired by cognitive priors, rather than as a direct neuroscience discovery.
2. On the Statistical Robustness of the Reported Results
To address the request for statistical evidence, we conducted multi-seed experiments (5 runs) and report the mean performance with standard errors and 95% confidence intervals. The Top-1 accuracy is 69.66% ± 1.03 (SE) with a 95% CI of [66.79, 72.53]; the Top-5 accuracy is 95.80% ± 0.26 (SE) with a 95% CI of [95.07, 96.53]. In addition, we performed paired t-tests comparing CAIA against UBP across the 10 subjects using seed-matched runs, which yielded t(9) = 7.13, p < 0.0001 for Top-1 and t(9) = 11.35, p < 0.0001 for Top-5. These results confirm that the observed improvements are statistically significant and consistent across both random seeds and subjects. We will include these analyses in the revised experiments section.
Table1: CAIA performance across 5 seeds.
Table2: UBP results for paired comparison.
Table3: Paired t-test results.
3. On Baseline Fairness and Protocol Consistency
We confirm that all compared methods are evaluated under exactly the same protocol. All baselines operate on the identical publicly released THINGS-EEG/MEG .pt files, with the same 250 Hz whitened preprocessing, 0–250 ms post-stimulus window, 17 posterior EEG channels, repeated-trial averaging (4/80), 200-way retrieval, and a unified OpenCLIP ResNet-50 visual encoder. For method-specific hyperparameters, we respected the original configurations where compatible and tuned CAIA under the same validation pipeline. This ensures that any differences in performance reflect architectural choices rather than preprocessing, encoder, or evaluation protocol variations. To further address the concern about the large gains, we note that scaling UBP's encoder capacity to match CAIA's parameter count still leaves it far below CAIA's performance (51.3% vs. 70.3% Top-1), reinforcing that the improvement is not attributable to protocol or implementation advantages. We will add a dedicated paragraph to the revised manuscript clarifying these protocol-sharing details.
4. On the Reporting Accuracy and Cross-Subject Generalization
We agree that the gap between subject-dependent and subject-independent decoding remains substantial. This reflects the strong inter-subject variability of EEG signals and should be treated as a limitation rather than a solved problem. Nevertheless, CAIA improves over UBP in the subject-independent EEG setting from 12.4%/33.4% to 16.4%/45.7%, and in the subject-independent MEG setting from 2.2%/10.4% to 7.5%/21.8%. We will revise the discussion to emphasize that CAIA improves cross-subject robustness relative to prior baselines, but does not eliminate the subject-generalization challenge.
5. On Attention and Frequency Interpretability
To strengthen the attention analysis beyond visualization, we performed an EEG-shuffling counterfactual in which only the CrossModalAttention module receives EEG from a randomly selected different sample. This reduces performance from 70.3%/96.1% to 64.5%/92.0%, and the spatial correlation between correctly paired and shuffled attention maps is only 0.0057. This suggests that the gain from attention depends on correct EEG-image pairing rather than a static saliency or center-bias prior.
For IBWave, we tested stability across seeds and subjects. The learned frequency weights are stable, with within-subject cross-seed variation <=0.005, and removing the entropy regularizer reduces performance from 70.3%/96.1% to 67.8%/94.2%. We will add these analyses while framing them as suggestive interpretability evidence, not direct mechanistic proof.
6. On Repeated-Trial Averaging and BCI Relevance
We agree that repeated-trial averaging limits direct applicability to single-trial real-time BCI. In the revision, we will qualify the BCI-related claims and explicitly state that the current evaluation follows the THINGS-EEG protocol using averaged repeated trials. We will present single-trial decoding and real-time deployment as future directions rather than demonstrated capabilities of the current study.
7. On Retrieval-Only Evaluation
We agree that the current experiments evaluate zero-shot retrieval rather than reconstruction or image generation. We will revise the manuscript to avoid implying that the method has already been validated across all neural-visual decoding tasks. The current contribution is a retrieval-focused framework for improving EEG/MEG-to-visual alignment, and extension to reconstruction or generation will be described as future work.
8. On Table Bolding
We also thank the reviewer for pointing out the non-standard table bolding. We will revise all tables to bold only the single best entry in each comparison.
Thank you again for your insightful and meticulous feedback.