Abstract. Medical image segmentation remains fragmented along two axes: segmentation paradigms and data dimensionality. Existing methods are typically developed separately for semantic, in-context, and interactive segmentation, and are further specialized to either native 2D images or 3D volumetric data. In clinical practice, however, segmentation workflows take many forms: a case may be initialized by semantic prediction, reference-guided segmentation, or user interaction. Regardless of how it begins, fine-grained refinement is naturally performed on 2D views; for volumetric scans, such 2D edits must propagate coherently to the rest of the volume. We present UniPro, a unified model that bridges segmentation paradigms and data dimensionality, using propagation to extend 2D segmentation to 3D volumes. Our key insight is that volumetric propagation and in-context segmentation share the same reference-conditioned prediction mechanism, differing only in whether the reference image–mask pairs come from other cases or from previously segmented neighboring slices. Building on this view, UniPro supports semantic, in-context, interactive, and propagation-based segmentation within a single slice-based framework, using class priors, reference exemplars, user clicks, and neighboring-slice predictions as mode-specific conditioning inputs. To improve propagation reliability, UniPro further incorporates bidirectional and 3D supervision to regularize slice-wise propagation beyond per-slice losses. Extensive experiments across diverse modalities and anatomies show that UniPro achieves strong performance across all segmentation settings, enabling annotation-efficient 3D segmentation from sparse 2D initialization and reducing slice-by-slice correction effort.

Are you an author? Claim this paper to see who's reading it, with views and other statistics, and to write about it here.

Claim this paper
How does this paper connect to your work? Write how you built on it, compared with it or reproduced it, or add a summary, a critique or errata.
Or make it interactive:
Start writing

edit · history

DateVersionSubmitted toPDFEvidence
4 May 2026NeurIPS 2026submittedNeurIPS 2026Accept (poster)reviews ↓[1]PDF[1]
Missing a version?

NeurIPS 2026

Accept (poster) · 3 reviews · OpenReview

Updated 25 Nov 2026, 03:43 UTC.

Program Chairs · DecisionOpenReview ↗
Decision
Accept (poster)
Read decision
Meta-review

Dear Authors,

Thank you for submitting your work for review. Final reviews have been all positive (5, 5, 4). Initially reviewers have assigned borderline accept scores (4). Authors provided detailed rebuttals hence were able to convince two reviewers for updating the rank. 9t86’s had provided detailed questions to be answered by the reviewers. Rebuttal was able to answer reviewers' concerns who increased the rating from 4 to 5. NSmN, also raised it to 5.

3TgJ, maintained the original score, However, comments were on the positive side. Reviewer, among other concerns, had requested quantitative analysis, which authors provided. 3TgJ was satisfied by the quantitative comparisons presented in the rebuttal, indicating that "revised efficiency-related statements are now better supported by the experimental evidence.". Authors please work to include this in the main draft. 3TgJ during discussion with the authors, added "The described practical scenarios clearly position UniPro relative to specialized models, while appropriately acknowledging that a dedicated model may remain preferable for a fixed, single-task application." This acknowledgement is quite important and should be part of the main manuscript.

Since rebuttal played a vital role in changing the score, we encourage you to incorporate all the comments by the reviewers and necessary results presented in rebuttal to be incorporated in the final version. For example, authors have stated that " BraTS, LiTS, and KiTS visualizations are included in the revised appendix, together with the corresponding discussion." The main manuscript should have a sentence directing readers towards supplementary material for details. Experiments on Sli2Vol, Sli2Vol+, and Vol2Flow, as reported in the rebuttal should be moved to supplementary material. Above are a few examples, please cover all the comments and points raised by reviewers and discussed in the rebuttal.

Adding the limitation section is good advice (NSmN), authors should add it. If space is limited, a pointer should be added to the main-paper towards supplementary material. For example, discussion in rebuttal regarding “highly non-convex, multi-component, and weakly continuous structures” should be highlighted in the main draft at least and then the reader might be directed to the supplementary material.

AC concern: Authors in their rebuttal are citing a lot of information in the appendix. We encourage them to incorporate summary of that information in the main draft, and there direct readers to the supplementary material.

Congratulations.

regards

AC

Final justification

9t86: raised the score NSmN: indicated that authors have resolved comments well but maintained rating. <--- later raised the score to 5. 3TgJ, maintained the rating but the final comments to the authors were on positive side.

Area Chair qCj2 · Meta-reviewOpenReview ↗
Read meta-review
Meta-review

Dear Authors,

Thank you for submitting your work for review. Final reviews have been all positive (5, 5, 4). Initially reviewers have assigned borderline accept scores (4). Authors provided detailed rebuttals hence were able to convince two reviewers for updating the rank. 9t86’s had provided detailed questions to be answered by the reviewers. Rebuttal was able to answer reviewers' concerns who increased the rating from 4 to 5. NSmN, also raised it to 5.

3TgJ, maintained the original score, However, comments were on the positive side. Reviewer, among other concerns, had requested quantitative analysis, which authors provided. 3TgJ was satisfied by the quantitative comparisons presented in the rebuttal, indicating that "revised efficiency-related statements are now better supported by the experimental evidence.". Authors please work to include this in the main draft. 3TgJ during discussion with the authors, added "The described practical scenarios clearly position UniPro relative to specialized models, while appropriately acknowledging that a dedicated model may remain preferable for a fixed, single-task application." This acknowledgement is quite important and should be part of the main manuscript.

Since rebuttal played a vital role in changing the score, we encourage you to incorporate all the comments by the reviewers and necessary results presented in rebuttal to be incorporated in the final version. For example, authors have stated that " BraTS, LiTS, and KiTS visualizations are included in the revised appendix, together with the corresponding discussion." The main manuscript should have a sentence directing readers towards supplementary material for details. Experiments on Sli2Vol, Sli2Vol+, and Vol2Flow, as reported in the rebuttal should be moved to supplementary material. Above are a few examples, please cover all the comments and points raised by reviewers and discussed in the rebuttal.

Adding the limitation section is good advice (NSmN), authors should add it. If space is limited, a pointer should be added to the main-paper towards supplementary material. For example, discussion in rebuttal regarding “highly non-convex, multi-component, and weakly continuous structures” should be highlighted in the main draft at least and then the reader might be directed to the supplementary material.

AC concern: Authors in their rebuttal are citing a lot of information in the appendix. We encourage them to incorporate summary of that information in the main draft, and there direct readers to the supplementary material.

Congratulations.

regards

AC

Final justification

9t86: raised the score NSmN: indicated that authors have resolved comments well but maintained rating. <--- later raised the score to 5. 3TgJ, maintained the rating but the final comments to the authors were on positive side.

2 comments
Authors · CommentOpenReview ↗

We sincerely thank the Area Chair for the careful meta-review and for highlighting the central concerns raised by the reviewers. We also appreciate that all three reviewers provided positive overall assessments, recognizing the motivation, unified formulation, methodological clarity, broad experimental coverage, and generalization performance of UniPro.

We have responded carefully to every reviewer question, including the issues emphasized in the meta-review. In particular, we clarified the fairness of the baseline training data and propagation initialization, analyzed robustness to non-ideal seed selection, added comparisons with Sli2Vol+, Vol2Flow, and a propagation-only training variant, and reported statistical variability for the propagation results. We also conducted new qualitative analyses of successful and failure cases on LiTS, KiTS, and the unseen-anatomy BraTS dataset. In addition, we clarified the applicability to anisotropic volumes and non-convex structures, and provided a quantitative runtime and memory comparison with a parameter-matched 3D nnU-Net.

We thank the Area Chair and the reviewers for the detailed and constructive feedback, which has helped us substantially improve the clarity, empirical support, and practical positioning of the paper. We hope that our responses and additional evidence address the remaining concerns and support a favorable final assessment.

Authors · CommentOpenReview ↗

As Phase 3 of the review process begins, we would like to briefly update the Area Chair on the rebuttal discussion. We have responded to all questions and concerns raised by the reviewers. Reviewer 9t86 has reconsidered our response and updated the rating from 4 to 5 with confidence 5. Reviewer 3TgJ has also confirmed that our responses addressed the practical-positioning and efficiency concerns and found the qualitative analysis helpful; we have committed to including the corresponding visualizations in the revised appendix. We have also provided detailed clarifications to Reviewer NSmN. Overall, all three reviewers have expressed a positive view of the paper and recognized its motivation, unified formulation, broad evaluation, and practical value in original comments or comments on our rebuttal.

We sincerely appreciate the Area Chair’s and reviewers’ time and consideration during this busy stage of the process.

Reviewer NSmNOpenReview ↗
Rating
5/6
Confidence
4/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

The authors proposed UniPro, it bridges medical image segmentation paradigms and data dimensionality, unifies multi-mode and multi-dimension medical image segmentation. Shown in the results, UniPro achieves strong performance across different segmentation settings, enabling annotation-efficient 3D segmentation from sparse 2D initialization and reducing slice-by-slice correction effort. The performance looks good, and the evaluation is comprehensive, which leads to potential good generalizability.

Strengths and weaknesses

Strength:

  1. The problem is well-motivated and is a general current issue in medical image segmentation tasks.
  2. The coverage and diversity of the datasets, and the baseline comparisons, are satisfactory and comprehensive.
  3. The description of the methodologies are clear, and the generalizability looks good to me.

Weakness:

  1. Minor limitation on organs/tissue that with 3D non-convex shape.
  2. I would suggest the authors adding discussions in between isotropic vs anisotropic images.
Questions
  1. It would be nicer if the authors can describe what is “propagation model” before or associated with Figure 1.
  2. In the training using formula (38), did you try to freeze any most beginning layers, or you just run the training for all the layers? If yes/no, I would like to hear comments from the authors about the findings.
  3. “Sparse foreground–background prototypes” I would like to understand why the authors decide to used “sparse” representations here. There is no explanation of the intensions there.
  4. Is the method limited to only isotropic images? Or does it work also for anisotropic images? I didn’t see the discussion in the manuscript and would like to learn more about it. In addition, if it works for anisotropic images, will it still be generalizable enough to match your statements for all anisotropic images for different image modalities?
  5. In formula (10), will this setting be a bit harmful to the segmentation results for the first and last slice of the volumetric images?
  6. I would like to hear from the authors about organs/tissue with 3D non-convex shape. The authors indeed cover very diverse dataset and thus variations, however, some organs or tissue with 3D non-convex shape seem not be included, like intestine. Intestine might show multiple organ regions in one single 2D slice, will this impact input info of semantic, in-context, and interactive? Especially the interactive one since the design was “one-click” and thus cannot cover all regions in one single 2D slice. But I would like to also hear the authors thoughts on the impact related to other two input info.
Limitations
  1. Limitations were mentioned in their work under the Discussion section together with other texts, but not explicitly in a single section.
Final justification

The authors have resolved my comments well. I would like to keep my rating.

Updated my rating to be Accept

Formatting concerns

N/A

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Response to Reviewer NSmN

We thank the reviewer for the positive assessment of the motivation, methodological clarity, dataset diversity, and generalization performance. We address the questions below.

Question 1: Definition of “propagation model”

We will clarify this term in the penultimate sentence of the second paragraph of the Introduction, ensuring that readers understand propagation before encountering the central contribution of UniPro and Figure 1. Specifically, we will revise the sentence as follows:

“For volumetric data, such 2D edits can be extended throughout the volume using the propagation model, which sequentially propagates segmentation from one or more initialized slices to the remaining slices while preserving local editability.”

Question 2. Freezing the encoder during Stage-II training

Thank you for this insightful question. Freezing the encoder is indeed an attractive option for reducing Stage-II training cost. We explored this setting during preliminary model development and observed worse propagation performance than with end-to-end fine-tuning. Because this experiment was conducted in a very early stage, we do not report it as a controlled ablation.

We believe this degradation arises from the distribution shift between the two training stages. Stage I learns reference-conditioned matching between a query image and a single image–mask pair, usually with a directly provided reference mask. In contrast, Stage II requires cross-slice matching against multiple neighboring references, whose masks may contain accumulated propagation errors. The encoder therefore needs to adapt its representation jointly with the remaining model components to handle this more challenging and propagation-specific reference distribution.

The results in Table 3 are consistent with this interpretation: propagation-specific supervision improves all initialization modes and also changes native 2D performance, suggesting that Stage-II training adapts the shared model rather than only a propagation-specific output component. We therefore fine-tune the full model during Stage II and will clarify this design choice in Appendix A.3.1.

Question 3. Definition of "Sparse foreground–background prototypes"

Thank you for pointing out this ambiguity. Here, “sparse” is used relative to the spatially dense 2-D feature map. Specifically, these representations are a small set of 1-D queries that summarize object-level foreground/background semantics, whereas the dense feature map preserves spatially aligned, location-specific details. To make this distinction easier to understand and align the terminology with the other 1-D queries used throughout the manuscript, we will rename them as “sparse foreground–background queries” and clarify this definition in Sec. 3.2.

Question 4. Applicability to anisotropic volumes

Thank you for raising this point. UniPro does not assume isotropic voxel spacing. As a slice-based framework, it processes in-plane images according to their slice order, while voxel spacing, slice thickness, and physical distance are not provided as model inputs. Therefore, unequal in-plane and through-plane spacing does not violate any architectural or modeling assumption of UniPro. This property is also consistent with our reference-conditioned formulation. In Stage I, the query image and reference image–mask pair may come from different patients, so there is no meaningful physical distance or shared voxel spacing between them. Stage II specializes the same mechanism to neighboring slices, so correspondence is learned primarily from visual and semantic similarity rather than explicit voxel-level continuity. Strong anisotropy may reduce the visual similarity between adjacent slices, but it does not change the formulation itself.

Our experiments do not apply a single isotropic resampling strategy to all volumetric datasets. AbdomenCT-1K, CHAOS, BTCV, and KiTS are resampled to 1.5×1.5×1.5 mm, whereas M&Ms and ACDC are resampled only in-plane to 1.5×1.5 mm while preserving their original 5–10 mm through-plane spacing. These cardiac MRI datasets therefore remain strongly anisotropic during both training and evaluation. These results demonstrate applicability to the heterogeneous isotropic and anisotropic settings represented in our benchmarks, rather than invariant performance under arbitrary anisotropy or across all imaging modalities. We will add a detailed dataset-specific preprocessing summary to the appendix, including the resampling strategy for each dataset, intensity preprocessing, final in-plane resizing, and a discussion of the resulting isotropic or anisotropic input characteristics.

Question 5. Effect of Eq. (10) on the first and last slices

Thank you for raising this question. This formulation does not disadvantage the first or last slice. Instead, it imposes a bidirectional cycle-consistency constraint on the propagation process. Starting from the first slice, the prediction is propagated forward to the last slice, which then serves as the reference for backward propagation. If the propagation is sufficiently accurate, the backward pass should recover the segmentation of the first slice.

The last slice is supervised during forward propagation, while the first slice is explicitly reconstructed during the backward pass. We further assign a larger weight, λseed\lambda_{\mathrm{seed}}, to this reconstruction term, encouraging the model to recover the initial segmentation as accurately as possible after traversing the full propagation cycle. This strengthened supervision is intended to suppress accumulated drift across the volume rather than weaken the boundary predictions.

Question 6. Non-convex and multi-component structures

Thank you for raising this important point. Although our current benchmarks do not include intestine segmentation, they do include highly irregular and non-convex targets such as liver, kidney, and brain tumors. These lesions vary substantially across patients and may appear as fragmented or disconnected regions within a single slice, so the model has already been evaluated on targets that differ considerably from simple convex anatomy.

For semantic and in-context segmentation, there is no structural assumption that the target must be convex or single-component. The semantic query predicts the complete class mask, while the in-context branch transfers information from all foreground regions in the reference mask. For interactive segmentation, a single positive click may initially emphasize one connected component, but this is a general limitation of one-click interaction rather than one specific to UniPro. Additional positive and negative clicks can recover missed regions, and semantic or in-context segmentation can first provide a more complete initialization before interactive refinement.

We agree that highly non-convex, multi-component, and weakly continuous structures remain more challenging, especially when small components abruptly appear, disappear, split, or merge across slices. To further analyze this behavior, we examined representative success and failure cases from LiTS, KiTS, and the unseen-anatomy BraTS dataset. Each example shows the seed slice, propagated 2D slices at increasing distances, and the corresponding 3D ground-truth and predicted masks. The successful cases show that UniPro can propagate large, irregular tumors when their appearance remains relatively consistent and traceable across adjacent slices. Failures are more likely for small, diffuse, or spatially separated lesions with weak cross-slice correspondence. In LiTS and KiTS, small tumor foci may emerge or disappear far from the initialized region and are therefore easily missed. On BraTS, UniPro performs well for compact, coherent tumors but struggles with heterogeneous, fragmented lesions with diffuse boundaries. Because brain anatomy is unseen during training, the model relies more on seed-based appearance matching and may miss components with different intensity or morphology.

These observations suggest that performance depends not only on geometric complexity, but also on component size, appearance consistency, and cross-slice continuity. We will include these representative success and failure visualizations in the appendix and expand the corresponding discussion.

About the Limitations

We agree that the limitations are currently embedded within the Discussion, where they are presented together with the corresponding design choices and empirical observations. Based on the reviewers’ feedback, we will consider further clarifying and consolidating the main limitations, including the 2D–3D trade-off, extreme anisotropy, propagation drift, and challenging non-convex or multi-component structures.

We hope these clarifications and additional analyses address the reviewer’s concerns and support a more favorable assessment of the paper.

Authors · CommentOpenReview ↗

Follow-up to Reviewer NSmN

We sincerely thank the reviewer for the thoughtful questions and constructive suggestions. We have clarified the definition of the propagation model, the Stage-II training strategy, the sparse query representation, applicability to anisotropic volumes, the bidirectional supervision, and the behavior on non-convex and multi-component structures. We hope these clarifications address the reviewer’s concerns and would welcome any further questions or discussion.

Reviewer 9t86OpenReview ↗
Rating
5/6
Confidence
5/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper proposes UniPro, a unified slice-based medical image segmentation framework that supports four segmentation modes: semantic segmentation, in-context segmentation, interactive segmentation, and propagation-based volumetric segmentation. It treats 3D volume propagation as a form of reference-conditioned in-context segmentation, where the reference image–mask pairs come from previously segmented neighboring slices rather than from external examples. Specifically, it uses a shared 2D encoder–decoder backbone with mode-specific conditioning inputs, including class priors, reference examples, user clicks, and neighboring-slice predictions. Experiments on multiple 2D and 3D medical datasets demonstrate the effectiveness of the proposed method.

Strengths and weaknesses

Strengths:

  1. The motivation of the paper is clear: clinicians may start from semantic prediction, reference examples, or user interactions, and then refine 3D volumes slice by slice. The proposed slice-based propagation framework is well aligned with this practical workflow.
  2. The idea is clean and interesting: instead of treating 3D propagation as a separate task, the paper views neighboring segmented slices as reference image–mask examples. This creates a unified mechanism for both in-context segmentation and volumetric propagation.
  3. Experiments on multiple 2D and 3D medical datasets demonstrate the effectiveness of the proposed method.
  4. Meaningful contributions: The main contribution is the formulation of volumetric propagation as reference-conditioned in-context segmentation. This is a meaningful contribution because many prior medical segmentation methods focus on only one or two of these settings. The unified design makes the method more flexible for real-world annotation and correction workflows.
    

Weaknesses:

  1. My biggest concern is that the evaluation, while broad, raises some fairness and interpretation questions. For example, UniPro is trained as a unified multi-dataset, multi-mode model, while some baselines are specialized to particular modes or settings. It would be helpful to clarify whether all baselines have comparable access to the same data, supervision types, and propagation initialization.
  2. The propagation mechanism still depends heavily on seed quality and slice continuity. The method assumes that neighboring slices provide useful references and that the target structure changes smoothly along the propagation path. This may be less reliable for discontinuous lesions, sparse tumors, highly anisotropic scans, low-quality volumes, or cases where the chosen seed slice is not representative. The paper provides some seed-quality analysis, but more failure cases and robustness analysis would be better.
  3. The paper should compare with more propagation-based methods, such as Sli2Vol, Sli2Vol+, and Vol2Flow.
  4. Statistical significance analysis is needed because only single-value results are reported.

Overall, the strengths justify a positive rating.

Questions
  1. Were all baselines trained or fine-tuned using the same datasets, annotations, and train/test splits as UniPro? If not, please clarify which baselines used different training data, pretraining, or supervision. This is important to determine whether UniPro’s gains come from the unified formulation itself or from broader access to training data.

  2. In the propagation experiments, were all propagation baselines initialized with exactly the same seed slice and the same click/seed-mask quality as UniPro? Please clarify how a single positive click is converted into an initial mask for each method and whether this initialization is matched across methods.

  3. How sensitive is UniPro to non-ideal seed slice selection? For example, what happens when the seed slice is near the boundary of the organ, contains only a small part of the structure, or is selected randomly by a non-expert user?

  4. How does UniPro perform on discontinuous lesions, sparse tumors, fragmented regions, highly anisotropic scans, or low-quality volumes? Additional failure cases or stratified results based on target continuity and slice spacing would be helpful.

  5. Could the authors compare with recent propagation or 2D-to-3D methods such as Sli2Vol, Sli2Vol+, and Vol2Flow, or explain why these methods were not included?

  6. Are the reported Dice scores averaged over multiple runs or based on a single run? Please provide standard deviations, confidence intervals, or paired statistical tests, especially when the improvement over the strongest baseline is small.

  7. How much of the improvement comes from unified multi-mode Stage-1 pretraining, and how much comes from Stage-2 propagation-specific losses? An ablation comparing “propagation-only training without unified Stage-1 pretraining” against the full UniPro pipeline would clarify the source of the gains.

Limitations

No

Final justification

Thank you to the authors for their detailed rebuttal. The responses have satisfactorily addressed most of my concerns and clarified the key issues I raised. Consequently, I am increasing my overall score from 4 to 5.

Formatting concerns

No

2 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Response to Reviewer 9t86

Question1: Fairness of baseline training data and supervision

Thank you for raising this question. The relevant details are provided in Section 4.1 and Appendix A.5. All trainable baselines use the same dataset splits, annotations, preprocessing, and training budgets as UniPro. Universal 2D baselines such as Hermes and Iris are jointly trained on the same multi-dataset training collection as UniPro, whereas nnU-Net is trained separately for each dataset following its standard dataset-specific setting. Propagation baselines are trained and evaluated on the same corresponding 3D datasets as UniPro. Released medical checkpoints are not used to avoid potential training-data overlap. Therefore, UniPro does not have access to any additional medical data or annotations. We will further clarify the training data, initialization, and supervision used by each baseline in Appendix A.5.

Question2: Matched initialization for propagation baselines

Thank you for requesting this clarification. For each volume–target pair, all propagation methods are initialized from the same seed-slice index. User interactions are also simulated consistently across methods using the policy described in Appendix A.4: clicks are represented as binary disk maps, and corrective clicks are placed at the centroid of the largest connected error region. Given the shared click input, each method uses its own interaction and mask-prediction mechanism to generate the initial seed mask, which is then propagated through the volume. Therefore, the seed slice, click-generation strategy, click location, and interaction budget are strictly matched, while the resulting seed-mask quality remains method-dependent. This is intentional, since converting the same user click into an accurate initial mask is part of each method’s end-to-end click-to-volume segmentation capability. We will make this distinction more explicit in the Appendix A.4.

Question3: Robustness to non-ideal seed-slice selection

We have already included a controlled seed-position robustness study in Appendix D.3. On ACDC, we initialize propagation from slices located at the 20%, 40%, 50%, 60%, and 80% quantiles of the target-organ extent, as well as from a randomly selected target-containing slice. To isolate the effect of seed location, all settings use the ground-truth seed mask. The performance remains stable across these choices, with mean Dice ranging from 89.46% to 91.03%. Compared with the default median seed (90.98%), a random seed achieves 90.12%, while seeds closer to the two boundaries achieve 89.81% and 89.46%, respectively. The modest degradation near the two ends is expected, since boundary slices often contain smaller target regions with less distinct boundaries and therefore provide less informative references. Nevertheless, the overall variation remains limited, demonstrating that UniPro is robust to non-central and randomly selected seed slices.

Question 4. Robustness to discontinuous lesions, anisotropy, and low-quality volumes

Thank you for raising this important question. We appreciate that several reviewers independently highlighted these challenging settings. Due to the rebuttal length limit, we refer the reviewer to the following detailed responses rather than repeating the full analyses here.

For discontinuous, sparse, and fragmented targets, please refer to our response to Reviewer NSmN, Question 6: “Non-convex and multi-component structures,” and Reviewer 3TgJ, Question 1: “Qualitative analysis on BraTS and challenging tumor datasets.” These results show that UniPro can handle large irregular tumors when they remain visually coherent and traceable across slices, whereas small, diffuse, spatially separated, or highly heterogeneous components are more likely to be missed. For highly anisotropic scans, please refer to our response to Reviewer NSmN, Question 4: “Applicability to anisotropic volumes.” There, we clarify that UniPro does not assume isotropic spacing and is evaluated on both isotropically resampled CT datasets and strongly anisotropic cardiac MRI datasets with preserved through-plane spacing. We will add the qualitative success and failure cases, dataset-specific spacing and preprocessing details, and the corresponding limitations to the appendix and Discussion.

Question 5. Comparison with Sli2Vol, Sli2Vol+, and Vol2Flow

Thank you for pointing out these relevant 2D-to-3D propagation methods. When selecting the original baselines, we primarily focused on methods that support an interactive segmentation workflow, in which an initial slice can be segmented or corrected by the user and then propagated through the volume. This setting is aligned with the intended use of UniPro for interactive volumetric annotation. Sli2Vol, Sli2Vol+, and Vol2Flow follow a different line of work based mainly on self-supervised inter-slice correspondence or deformation estimation from sparsely annotated slices.

Nevertheless, we appreciate the reviewer’s suggestion and therefore implemented and evaluated Sli2Vol+ and Vol2Flow under the same controlled protocol. To eliminate differences caused by their initialization mechanisms, all methods were provided with the same seed-slice index and the same ground-truth seed mask. They were then trained and evaluated on the Abd-1K liver propagation task, enabling a fair comparison that isolates propagation performance rather than initial-mask quality.

Method AbdomenCT-1K Liver Dice
Vol2Flow 83.81
Sli2Vol+ 86.05
UniPro (GT seed) 94.03

Under this controlled setting, UniPro outperforms Sli2Vol+ and Vol2Flow by 7.98 and 10.22 Dice points, respectively. Given that this is a focused comparison on a single dataset and target structure, we report it here as supplementary rebuttal evidence rather than treating it as a comprehensive benchmark. However, we agree that Sli2Vol, Sli2Vol+, and Vol2Flow are the related 2D-to-3D propagation methods, and we will add and discuss them in the revised Related Work.

6. Question 6. Statistical reliability of the reported Dice scores

Thank you for raising this question. The results are based on one complete training run per method, as repeated training of a unified multi-dataset model is computationally expensive. For the Table 1 propagation experiments, we additionally report UniPro’s standard deviations and 95% confidence intervals across evaluated volume–target pairs using the Student’s tt-distribution.

Dataset Mean Dice SD 95% CI of mean
Abd-1K 88.62 12.64 [87.19, 90.05]
M&Ms 87.64 10.31 [87.01, 88.28]
ACDC 87.97 13.06 [86.49, 89.45]
CHAOS 89.70 9.05 [87.37, 92.04]
KiTS 76.95 18.94 [71.04, 82.85]
LiTS 66.95 28.60 [55.15, 78.76]
BTCV 84.40 14.70 [81.32, 87.48]
BraTS 54.89 23.03 [49.56, 60.23]

We further performed paired t-tests between UniPro and MedSAM2, the strongest propagation baseline in Table 1.

Dataset UniPro −- MedSAM2 pp-value
Abd-1K +2.33 0.0165
CHAOS $-$0.94 0.5254
M&Ms +4.67 5.49×10−115.49 \times 10^{-11}
LiTS +4.70 0.3136
KiTS +3.63 0.1911
BTCV +3.85 0.0035
ACDC +3.79 0.0066
BraTS +14.15 1.14×10−41.14 \times 10^{-4}

At the conventional p<0.05p<0.05 threshold, UniPro significantly outperforms MedSAM2 on Abd-1K, M&Ms, ACDC, BTCV, and BraTS. The confidence intervals are relatively narrow, generally within approximately $\pm$1–2 Dice points, indicating stable estimates of the reported mean performance. The wider intervals on KiTS and LiTS reflect their smaller evaluation sets and greater variability across volume–target pairs. BraTS also shows a wider interval, reflecting the substantially higher variability under the unseen-anatomy setting. We will add these statistics to the appendix and explicitly clarify that the reported results are obtained from a single training run.

Question 7. Contributions of Stage-I pretraining and Stage-II propagation training

Thank you for suggesting this important ablation. To disentangle the contributions of the two training stages, we evaluated three settings on ACDC. At inference time, all settings are initialized with the same ground-truth seed mask, so the comparison isolates propagation performance without being affected by initialization quality.

Training strategy ACDC Dice (GT seed)
Stage I only 87.29
Stage II only, without Stage-I pretraining 88.12
Full two-stage UniPro 90.98

Stage I alone already enables meaningful propagation, while Stage II alone can also learn propagation directly. However, neither single-stage setting achieves the full performance of the two-stage pipeline. The complete training strategy is therefore necessary for UniPro to retain strong semantic, in-context, and interactive segmentation capabilities while also achieving high-quality volumetric propagation. This setting differs from Table 3(b), where propagation is initialized by the model’s semantic prediction; here, all variants receive the same ground-truth seed mask to isolate propagation ability. We will add this result and the corresponding discussion to the appendix.

About the Limitations Section

We would like to clarify that the manuscript already discusses several limitations in the Discussion, where they are presented together with the corresponding design choices and empirical observations. We will further expand and clarify this discussion in the revision.

We sincerely thank the reviewer for the positive assessment of our motivation, methodological clarity, dataset diversity, and generalization performance, as well as for these thoughtful and constructive questions. We hope the clarifications and additional analyses above address the reviewer’s concerns and support a more favorable assessment of the paper.

Authors · CommentOpenReview ↗

Follow-up to Reviewer 9t86

We sincerely thank the reviewer for taking the time to carefully consider our rebuttal and update the assessment. We greatly appreciate the recognition and would welcome any further questions or discussion.

Reviewer 3TgJOpenReview ↗
Rating
4/6
Confidence
3/5
Quality
3/4
Clarity
3/4
Significance
3/4
Originality
3/4
Contribution type
general
Ethical concerns
NO or VERY MINOR ethics concerns only
Read review
Summary

This paper presents UniPro, a unified framework for semantic, in-context, interactive, and propagation-based medical image segmentation across 2D and 3D data. The key idea is to formulate volumetric propagation as reference-conditioned in-context prediction within a shared architecture. Extensive experiments demonstrate competitive performance across multiple segmentation settings.

Strengths and weaknesses

Strengths:

  1. The paper introduces an interesting reformulation that treats volumetric propagation as a special case of reference-conditioned in-context prediction. This perspective provides a unified view of propagation and in-context segmentation and enables multiple segmentation paradigms to be handled within a shared framework.
  2. The experimental evaluation covers a broad range of segmentation settings and generally supports the effectiveness of the proposed framework. The paper includes representative recent baselines and demonstrates competitive performance across multiple datasets, particularly in volumetric and propagation-based segmentation scenarios.

Weaknesses:

  1. The paper would benefit from qualitative visualization examples, particularly on the unseen-anatomy BraTS dataset. While the quantitative results demonstrate strong generalization performance, representative success and failure cases would help readers better understand the behavior of the proposed framework and its propagation mechanism.
  2. While the proposed framework shows clear advantages in volumetric and propagation settings, its benefits on native 2D tasks are less evident. Specialized models such as Hermes and Iris still achieve the best performance on several 2D datasets, and Stage-II propagation adaptation introduces a measurable trade-off in 2D performance. A clearer discussion of this trade-off would strengthen the practical implications of the work.
  3. The paper mentions the potential efficiency advantages of slice-based propagation compared with fully volumetric models. However, these practical advantages are not quantitatively evaluated. Reporting runtime, memory consumption, or inference cost would help better characterize the engineering benefits of the proposed framework.
  4. The paper shows that incorporating propagation improves performance in both semantic and in-context segmentation settings on the evaluated volumetric datasets. A more detailed analysis of the anatomical characteristics under which propagation is most beneficial (e.g., shape regularity, organ continuity, or lesion sparsity) would provide additional insight into the strengths and limitations of the proposed framework.
Questions
  1. Could the authors provide representative qualitative examples (including both successful and failure cases) on the unseen-anatomy BraTS dataset to better explain the observed generalization performance of the proposed framework?
  2. Given the observed trade-off between improved volumetric performance and reduced native 2D performance after Stage-II adaptation, under what practical scenarios do the authors envision the unified framework being preferred over specialized models?
  3. The paper highlights the potential efficiency advantages of slice-based propagation over fully volumetric models. Could the authors provide quantitative comparisons of runtime, memory consumption, or inference cost to support this claim?
Limitations

yes

Final justification

I maintain my original score after considering the authors’ revisions and responses.

Formatting concerns

I did not notice any major formatting, readability, or anonymity issues that would affect the review.

4 comments
Authors · RebuttalOpenReview ↗
Rebuttal

Response to Reviewer 3TgJ

Question 1. Qualitative analysis on BraTS and challenging tumor datasets

Thank you for this valuable suggestion. We agree that representative success and failure cases provide important insight beyond aggregate Dice scores. Following the reviewer’s suggestion, we conducted a broader qualitative analysis on the unseen-anatomy BraTS dataset, together with representative LiTS and KiTS cases containing irregular and multi-component tumors.

Each example visualizes the initialized seed slice, propagated 2D slices at increasing distances from the seed, and the corresponding 3D ground-truth and predicted masks. From these visualizations, we observe that UniPro can successfully propagate large and irregular tumors when their appearance remains relatively coherent and the target is traceable across adjacent slices. This behavior also generalizes to BraTS: although brain anatomy and brain tumors are entirely absent from training, UniPro can recover relatively compact and visually coherent lesions throughout the volume.

The failure cases reveal a consistent pattern across datasets. In LiTS and KiTS, small, diffuse, or spatially separated tumor foci may appear or disappear far from the initialized region, weakening their correspondence with the seed and leading to missed components or propagation into visually similar surrounding tissue. On BraTS, the failure case contains a highly heterogeneous and fragmented lesion with diffuse boundaries against surrounding brain tissue. Because both the anatomy and pathology are unseen during training, the model lacks a brain-specific semantic prior and relies more heavily on appearance matching to the initialized region. Consequently, components whose intensity or morphology differs substantially from the seed appearance are more likely to be missed.

Overall, the visual analysis suggests that generalization depends not only on whether the anatomy is seen during training, but also on component size, appearance consistency, and cross-slice continuity. We thank the reviewer for motivating this analysis, which helps clarify both UniPro’s ability to generalize to visually traceable unseen targets and its limitations on small, fragmented, or weakly continuous lesions. We will include these representative LiTS, KiTS, and BraTS success and failure visualizations in the appendix and expand the corresponding Discussion.

Question 2. Practical scenarios for preferring a unified framework over specialized models

Thank you for this important question. We envision UniPro being particularly useful in four practical scenarios: (1) multi-dataset or multi-modality deployment, where separate models would otherwise be required; (2) clinical workflows combining automatic initialization, interactive correction, and volumetric propagation; (3) large-scale 3D annotation or data curation, where slice-by-slice labeling is prohibitively expensive; and (4) challenging datasets or anatomical structures where fully automatic semantic segmentation remains unreliable.

UniPro jointly supports semantic, in-context, interactive, and propagation-based segmentation within a shared model. This reduces the need to train, deploy, and maintain separate models for different datasets and segmentation modes, while allowing users to switch between automatic prediction, reference-based initialization, and interactive refinement within the same workflow. For example, in tumor segmentation, an automatic semantic prediction may provide a reasonable initial mask but still miss small lesions or produce inaccurate boundaries. A clinician can correct the difficult slices through interactive clicks, after which UniPro propagates the corrected masks through the remaining volume. Similarly, when a reliable annotation from another case is available, in-context segmentation can provide the initialization before interactive refinement and volumetric propagation. In such settings, the practical bottleneck is often not generating an initial prediction, but efficiently inspecting and correcting the full volume.

This makes UniPro particularly suitable for heterogeneous clinical and annotation workflows with multiple segmentation needs and limited expert time. For a fixed application involving only a single specialized 2D or 3D task, a dedicated model may still be preferable. We will clarify these practical scenarios and strengthen the comparison between unified and specialized models in the Discussion.

Question 3. Quantitative comparison of runtime, memory, and inference cost

Thank you for this request. We conducted a controlled comparison between UniPro and a parameter-matched 3D nnU-Net.

All measurements were conducted on Abd-1K test volumes using a single NVIDIA Quadro RTX 8000 GPU with a batch size of 1. The 3D nnU-Net uses 1.5 mm isotropic inputs with 1283128^3 sliding-window inference, while UniPro processes chunks of eight 3-channel 512×512512 \times 512 slices. We report the median per-volume runtime and peak GPU memory.

Model Parameters Native input Inference time Peak inference memory
3D nnU-Net 31.84M 1283128^3 patch 9.3 s 3.60 GB
UniPro 32.84M 8×3×512×5128 \times 3 \times 512 \times 512 chunk 28.0 s 1.93 GB

The results show a clear memory–runtime trade-off. UniPro requires approximately 46% less peak inference memory than the parameter-matched 3D nnU-Net (1.93 GB vs. 3.60 GB), but has a longer per-volume inference time (28.0 s vs. 9.3 s). This comparison also reflects their different native deployment settings. UniPro preserves a higher in-plane resolution of 512×512512 \times 512, retaining finer spatial details for inspecting and editing individual slices, whereas the 3D nnU-Net operates on 1283128^3 patches after volumetric resampling. The higher latency of UniPro is partly due to the sequential dependency of propagation: predictions from earlier steps are used as references for subsequent slices, which limits parallelization across the full volume. In contrast, the 3D nnU-Net processes an entire 1283128^3 patch in one forward pass, and its sliding-window patches can be evaluated independently, resulting in faster overall inference.

Accordingly, we will clarify the relevant statements in the manuscript:

  • Section 2.2. We will retain the statement that conventional 3D segmentation models often incur higher computational and memory costs than 2D models. This comparison concerns standard 2D slice and 3D volumetric modeling and does not imply that propagation-based inference is faster than volumetric inference.

  • Section 2.3. We will revise
    “Compared with full 3D models, they can reduce computational cost while retaining slice-level modeling and editability”
    to
    “Compared with full-volume 3D processing, propagation-based models retain slice-level modeling and local editability through sequential slice-wise prediction.”

We will add this quantitative comparison to the appendix and revise the manuscript so that all efficiency-related statements are consistent with the experimental evidence. Specifically, we will avoid broad claims that propagation is generally computationally cheaper than volumetric inference and instead distinguish among peak memory, inference latency, annotation effort, and slice-level editability. These revisions will make clear that UniPro’s main contribution is its unified support for semantic, in-context, interactive, and propagation-based segmentation, enabling flexible transitions among these modes while substantially reducing manual annotation effort and preserving slice-level editability, rather than providing faster inference.

We sincerely thank the reviewer for the positive assessment of our unified formulation, broad experimental evaluation, and propagation performance, as well as for the thoughtful and constructive questions. These suggestions have helped us better clarify the practical scope, computational trade-offs, and generalization behavior of UniPro. We hope that the additional analyses and revisions above address the reviewer’s concerns and support a more favorable assessment of the paper.

Authors · CommentOpenReview ↗

Follow-up to Reviewer 3TgJ

We sincerely thank the reviewer for the careful and constructive feedback. We have addressed each of the raised concerns and added new qualitative analyses, a runtime and memory comparison, and a clearer discussion of the practical scenarios and trade-offs of the unified framework. We hope these additions are helpful and would be grateful for any further discussion.

Reviewer 3TgJ · CommentOpenReview ↗

For Q1: The discussion of the success and failure cases is helpful. However, the corresponding visualizations are not available in the rebuttal for direct assessment. Please ensure that these representative examples are included in the revised appendix as stated.

For Q2: The described practical scenarios clearly position UniPro relative to specialized models, while appropriately acknowledging that a dedicated model may remain preferable for a fixed, single-task application. This adequately addresses my concern.

For Q3: Thank you for the quantitative comparison. The results clearly demonstrate the trade-off between peak memory consumption and inference time. The revised efficiency-related statements are now better supported by the experimental evidence.

Authors · CommentOpenReview ↗

We sincerely thank the reviewer for the careful follow-up and for confirming that our responses have addressed the corresponding concerns. We also appreciate the reminder regarding Q1. We agree that representative qualitative success and failure cases are important for understanding the model’s behavior beyond aggregate metrics. As this important point was raised by multiple reviewers, we will ensure that the BraTS, LiTS, and KiTS visualizations are included in the revised appendix, together with the corresponding discussion. Thank you again for the constructive feedback, which has helped us improve both the empirical presentation and the practical positioning of the paper.

From OpenReview, CC BY 4.0. Authors as signed there; shown unedited.